Rothfuss, Michael A; Unadkat, Jignesh V; Gimbel, Michael L; Mickle, Marlin H; Sejdić, Ervin
2017-03-01
Totally implantable wireless ultrasonic blood flowmeters provide direct-access chronic vessel monitoring in hard-to-reach places without using wired bedside monitors or imaging equipment. Although wireless implantable Doppler devices are accurate for most applications, device size and implant lifetime remain vastly underdeveloped. We review past and current approaches to miniaturization and implant lifetime extension for wireless implantable Doppler devices and propose approaches to reduce device size and maximize implant lifetime for the next generation of devices. Additionally, we review current and past approaches to accurate blood flow measurements. This review points toward relying on increased levels of monolithic customization and integration to reduce size. Meanwhile, recommendations to maximize implant lifetime should include alternative sources of power, such as transcutaneous wireless power, that stand to extend lifetime indefinitely. Coupling together the results will pave the way for ultra-miniaturized totally implantable wireless blood flow monitors for truly chronic implantation. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Mau, Jochen; Behneke, Alexandra; Behneke, Nikolaus; Fritzemeier, Claus Udo; Gomez-Roman, German; d'Hoedt, Bernd; Spiekermann, Hubertus; Strunz, Volker; Yong, Mei
2003-01-01
Two treatment concepts for implant-supported bar retention of mandibular overdentures-2 intramobile cylinder (IMZ) implants and a Dolder bar and 4 titanium plasma-sprayed (TPS) screw implants and an angulated bar-were compared in a randomized controlled clinical trial with respect to postprosthetic efficacy and safety. Four hundred twenty-five patients with edentulous mandibles were enrolled; 212 were randomized to TPS implants (control group) and 213 to IMZ implants (test group). Endpoints were occurrences of postprosthetic integration deficiency (ID), functional deficiency (FD), and complications. The trial was sized to detect a 10% difference in 5-year ID-free postprosthetic system lifetime with a power of 80%. With 340 protocol-completed cases, the trial achieved its predetermined power. The 2 systems did not show statistically significant differences in occurrences of postprosthetic ID and FD; 5-year occurrence-free postprosthetic system lifetime probabilities were estimated as 42.5% with IMZ and 42.8% with TPS, for ID; and as 82.6% with IMZ and 87.2% with TPS, for FD. However, at 3 to 6 months after surgery, mean Periotest values were significantly higher (P = .0001 without adjustment) with IMZ implants (5.6, SD 4.2) than with TPS implants (0.8, SD 4.3). TPS implants showed a higher incidence of inflammation and recession, while IMZ implants had a higher incidence of implant fracture after functional loading. The system-wise approach overcomes potential bias with implant-wise analyses. A combination of radiographic and clinical criteria distinguishes between desirable integration and functional anchorage. The in situ survival rates at 5 years in this study (95% for IMZ, 92% for TPS) match rates reported in the literature. This study demonstrated equivalent efficacy of 2 IMZ cylinders and 4 TPS screws in implant-supported, bar-retained mandibular overdentures and indicated a higher rate of complications with the TPS screw implants.
Duan, Yuanyuan; Gonzalez, Jorge A; Kulkarni, Pratim A; Nagy, William W; Griggs, Jason A
2018-06-16
To validate the fatigue lifetime of a reduced-diameter dental implant system predicted by three-dimensional finite element analysis (FEA) by testing physical implant specimens using an accelerated lifetime testing (ALT) strategy with the apparatus specified by ISO 14801. A commercially-available reduced-diameter titanium dental implant system (Straumann Standard Plus NN) was digitized using a micro-CT scanner. Axial slices were processed using an interactive medical image processing software (Mimics) to create 3D models. FEA analysis was performed in ABAQUS, and fatigue lifetime was predicted using fe-safe ® software. The same implant specimens (n=15) were tested at a frequency of 2Hz on load frames using apparatus specified by ISO 14801 and ALT. Multiple step-stress load profiles with various aggressiveness were used to improve testing efficiency. Fatigue lifetime statistics of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined using SEM with fractographic technique to determine the failure mode. FEA predicted lifetime was within the 95% confidence interval of lifetime estimated by experimental results, which suggested that FEA prediction was accurate for this implant system. The highest probability of failure was located at the root of the implant body screw thread adjacent to the simulated bone level, which also agreed with the failure origin in physical specimens. Fatigue lifetime predictions based on finite element modeling could yield similar results in lieu of physical testing, allowing the use of virtual testing in the early stages of future research projects on implant fatigue. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
Evidence of low injection efficiency for implanted p-emitters in bipolar 4H-SiC high-voltage diodes
NASA Astrophysics Data System (ADS)
Matthus, Christian D.; Huerner, Andreas; Erlbacher, Tobias; Bauer, Anton J.; Frey, Lothar
2018-06-01
In this study, the influence of the emitter efficiency on the forward current-voltage characteristics, especially the conductivity modulation of bipolar SiC-diodes was analyzed. It was determined that the emitter efficiency of p-emitters formed by ion implantation is significantly lower compared to p-emitters formed by epitaxy. In contrast to comparable studies, experimental approach was arranged that the influence of the quality of the drift-layer or the thickness of the emitter on the conductivity modulation could be excluded for the fabricated bipolar SiC-diodes of this work. Thus, it can be established that the lower emitter injection efficiency is mainly caused by the reduced electron lifetime in p-emitters formed by ion implantation. Therefore, a significant enhancement of the electron lifetime in implanted p-emitters is mandatory for e.g. SiC-MPS-diodes where the functionality of the devices depends significantly on the injection efficiency.
NASA Astrophysics Data System (ADS)
Elahi, Sakib F.; Lee, Seung Y.; Lloyd, William R.; Chen, Leng-Chun; Kuo, Shiuhyang; Zhou, Ying; Kim, Hyungjin M.; Kennedy, Robert; Marcelo, Cynthia; Feinberg, Stephen E.; Mycek, Mary-Ann
2018-02-01
Clinical translation of engineered tissue constructs requires noninvasive methods to assess construct health and viability after implantation in patients. However, current practices to monitor post-implantation construct integration are either qualitative (visual assessment) or destructive (tissue histology). As label-free fluorescence lifetime sensing can noninvasively characterize pre-implantation construct viability, we employed a handheld fluorescence lifetime spectroscopy probe to quantitatively and noninvasively assess tissue constructs that were implanted in a murine model. We designed the system to be suitable for intravital measurements: portability, localization with precise maneuverability, and rapid data acquisition. Our model tissue constructs were manufactured from primary human cells to simulate patient variability and were stressed to create a range of health states. Secreted amounts of three cytokines that relate to cellular viability were measured in vitro to assess pre-implantation construct health. In vivo optical sensing assessed tissue integration of constructs at one-week and three-weeks post-implantation. At one-week post-implantation, optical parameters correlated with in vitro pre-implantation secretion levels of all three cytokines (p < 0.05). This relationship was no longer seen at three-weeks post-implantation, suggesting comparable tissue integration independent of preimplantation health. Histology confirmed re-epithelialization of these constructs independent of pre-implantation health state, supporting the lack of a correlation. These results suggest that clinical optical diagnostic tools based on label-free fluorescence lifetime sensing of endogenous tissue fluorophores could noninvasively monitor post-implantation integration of engineered tissues.
Colvin, Arthur E; Jiang, Hui
2013-05-01
Understanding and improving in vivo materials related to signal stability and preservation for active chemical sensor and biosensor transduction systems is critical in achieving implantable medical sensors for long-term in vivo applications. During human in vivo clinical testing of an implantable glucose sensor based on a glucose sensitive hydrogel, post-explant analysis showed that the boronate recognition element had been oxidized from the fluorescent indicator, causing a rapid loss of signal within hours after implant. Additional wet-bench analytical evidence and reproduction in vitro suggests reactive oxygen species, particularly hydrogen peroxide (H2O2), stemming from natural inflammatory response to the material, to be the cause of the observed oxidative de-boronation. A 3-nm thick deposition of metallic platinum (Pt) placed by plasma sputtering onto the porous surface of the hydrogel, showed immediate protection from sensor signal loss due to oxidation both in vitro and in vivo, greatly extending the useful lifetime of the implantable glucose sensor from 1 day to an expected ≥6 months. This finding may represent a new strategy to protect an implanted material and/or device from in vivo oxidative damage, leading to much improved overall stability and reliability for long-term applications. Copyright © 2012 Wiley Periodicals, Inc.
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices.
Vanhoestenberghe, A; Donaldson, N
2013-06-01
Corrosion is a prime concern for active implantable devices. In this paper we review the principles underlying the concepts of hermetic packages and encapsulation, used to protect implanted electronics, some of which remain widely overlooked. We discuss how technological advances have created a need to update the way we evaluate the suitability of both protection methods. We demonstrate how lifetime predictability is lost for very small hermetic packages and introduce a single parameter to compare different packages, with an equation to calculate the minimum sensitivity required from a test method to guarantee a given lifetime. In the second part of this paper, we review the literature on the corrosion of encapsulated integrated circuits (ICs) and, following a new analysis of published data, we propose an equation for the pre-corrosion lifetime of implanted ICs, and discuss the influence of the temperature, relative humidity, encapsulation and field-strength. As any new protection will be tested under accelerated conditions, we demonstrate the sensitivity of acceleration factors to some inaccurately known parameters. These results are relevant for any application of electronics working in a moist environment. Our comparison of encapsulation and hermetic packages suggests that both concepts may be suitable for future implants.
Percutaneous Pulmonary Valve Placement
Prieto, Lourdes R.
2015-01-01
Patients with congenital heart disease and pulmonary valve disease need multiple procedures over their lifetimes to replace their pulmonary valves. Chronic pulmonary stenosis, regurgitation, or both have untoward effects on ventricular function and on the clinical status of these patients. To date, all right ventricle–pulmonary artery conduits have had relatively short lifespans. Percutaneous pulmonary valve implantation, although relatively new, will probably reduce the number of operative procedures that these patients will have to undergo over a lifetime. Refinement and further development of this procedure holds promise for the extension of this technology to other patient populations. PMID:26175629
Age-Dependent Cost-Utility of Pediatric Cochlear Implantation
Semenov, Yevgeniy R.; Yeh, Susan T.; Seshamani, Meena; Wang, Nae-Yuh; Tobey, Emily A.; Eisenberg, Laurie S.; Quittner, Alexandra L.; Frick, Kevin D.; Niparko, John K.
2013-01-01
Objective Cochlear implantation has become the mainstay of treatment for children with severe-to-profound sensorineural hearing loss (SNHL). Yet, despite mounting evidence on the clinical benefits of early implantation, little data are available on the long-term societal benefits and comparative effectiveness of this procedure across various ages of implantation--a choice parameter for parents and clinicians with high prognostic value for clinical outcome. As such, the aim of the current study is to evaluate a model of the consequences of the timing of this intervention from a societal economic perspective. Average cost-utility of pediatric cochlear implantation by age at intervention will be analyzed. Design Prospective, longitudinal assessment of health-utility and educational placement outcomes in 175 children recruited from 6 US centers between November 2002 and December 2004, who had severe-to-profound SNHL onset within 1 year of age, underwent cochlear implantation before 5 years of age, and had up to 6 years of post-implant follow-up that ended in November 2008 to December 2011. Costs of care were collected retrospectively and stratified by pre-operative, operative, and post-operative expenditures. Incremental costs and benefits of implantation were compared between the three age groups and relative to a non-implantation baseline. Results Children implanted at <18 months of age gained an average of 10.7 QALYs over their projected lifetime as compared to 9.0 and 8.4 QALYs for those implanted between 18 and 36 months and at >36 months of age, respectively. Medical and surgical complication rates were not significantly different between the 3 age groups. Additionally, mean lifetime costs of implantation were similar between the 3 groups, at approximately $2,000/child/year (77.5 year life expectancy), yielding costs of $14,996, $17,849, and $19,173 per QALY for the youngest, middle, and oldest implant age groups, respectively. Full mainstream classroom integration rate was significantly higher in the youngest group at 81% as compared to 57% and 63% for the middle and oldest groups, respectively (p<0.05) after six years of follow-up. After incorporating lifetime educational cost savings, cochlear implantation led to net societal savings of $31,252, $10,217, and $6,680 for the youngest, middle, and oldest groups at CI, respectively, over the child’s projected lifetime. Conclusions Even without considering improvements in lifetime earnings, the overall cost-utility results indicate highly favorable ratios. Early (<18 months) intervention with cochlear implantation was associated with greater and longer quality of life improvements, similar direct costs of implantation, and economically-valuable improved classroom placement, without a greater incidence of medical and surgical complications when compared to cochlear implantation at older ages. PMID:23558665
Low-temperature positron annihilation study of B+-ion implanted PMMA
NASA Astrophysics Data System (ADS)
Kavetskyy, T. S.; Tsmots, V. M.; Voloshanska, S. Ya.; Šauša, O.; Nuzhdin, V. I.; Valeev, V. F.; Osin, Y. N.; Stepanov, A. L.
2014-08-01
Temperature dependent positron annihilation lifetime spectroscopy (PALS) measurements in the range of 50-300 K are carried out to study positronium formation in 40 KeV B+-ion implanted polymethylmethacrylate (B:PMMA) with two ion doses of 3.13 × 1015 and 3.75 × 1016 ions/cm2. The investigated samples show the various temperature trends of ortho-positronium (o-Ps) lifetime τ3 and intensity I3 in PMMA before and after ion implantation. Two transitions in the vicinity of ˜150 and ˜250 K, ascribed to γ and β transitions, respectively, are observed in the PMMA and B:PMMA samples in consistent with reference data for pristine sample. The obtained results are compared with room temperature PALS study of PMMA with different molecular weight (Mw) which known from literature. It is found that B+-ion implantation leads to decreasing Mw in PMMA at lower ion dose. At higher ion dose the local destruction of polymeric structure follows to broadening of lifetime distribution (hole size distribution).
NASA Technical Reports Server (NTRS)
Shogrin, Bradley; Jones, William R., Jr.; Wilbur, Paul J.; Pilar, Herrera-Fierro; Williamson, Don L.
1995-01-01
The lubricating lifetime of thin films of a perfluoropolyether (PFPE) based on hexafluoropropene oxide in the presence of ion implanted 440C stainless steel is presented. Stainless steel discs, either unimplanted or implanted with N2, C, Ti, Ti + N2, or Ti + C had a thin film of PFPE (60-400 A) applied to them reproducibly (+/- 20 percent) and uniformly (+/- 15 percent) using a device developed for this study. The lifetimes of these films were quantified by measuring the number of sliding-wear cycles required to induce an increase in the friction coefficient from an initial value characteristic of the lubricated wear couple to a final, or failure value, characteristic of an unlubricated, unimplanted couple. The tests were performed in a dry nitrogen atmosphere (less than 1 percent RH) at room temperature using a 3 N normal load with a relative sliding speed of 0.05 m/s. The lubricated lifetime of the 440C couple was increased by an order of magnitude by implanting the disc with Ti. Ranked from most to least effective, the implanted species were: Ti; Ti+C; unimplanted; N2; C approximately equals Ti+N2. The mechanism postulated to explain these results involves the formation of a passivating or reactive layer which inhibits or facilitates the production of active sites. The corresponding surface microstructures induced by ion implantation, obtained using x-ray diffraction and conversion electron Mossbauer spectroscopy, ranked from most to least effective in enhancing lubricant lifetime were: amorphous Fe-Cr-Ti; amorphous Fe-Cr-Ti-C + TiC; unimplanted; epsilon-(Fe,Cr)(sub x)N, x = 2 or 3; amorphous Fe-Cr-C approximately equals amorphous Fe-Cr-Ti-N.
Hermetic diamond capsules for biomedical implants enabled by gold active braze alloys.
Lichter, Samantha G; Escudié, Mathilde C; Stacey, Alastair D; Ganesan, Kumaravelu; Fox, Kate; Ahnood, Arman; Apollo, Nicholas V; Kua, Dunstan C; Lee, Aaron Z; McGowan, Ceara; Saunders, Alexia L; Burns, Owen; Nayagam, David A X; Williams, Richard A; Garrett, David J; Meffin, Hamish; Prawer, Steven
2015-01-01
As the field of biomedical implants matures the functionality of implants is rapidly increasing. In the field of neural prostheses this is particularly apparent as researchers strive to build devices that interact with highly complex neural systems such as vision, hearing, touch and movement. A retinal implant, for example, is a highly complex device and the surgery, training and rehabilitation requirements involved in deploying such devices are extensive. Ideally, such devices will be implanted only once and will continue to function effectively for the lifetime of the patient. The first and most pivotal factor that determines device longevity is the encapsulation that separates the sensitive electronics of the device from the biological environment. This paper describes the realisation of a free standing device encapsulation made from diamond, the most impervious, long lasting and biochemically inert material known. A process of laser micro-machining and brazing is described detailing the fabrication of hermetic electrical feedthroughs and laser weldable seams using a 96.4% gold active braze alloy, another material renowned for biochemical longevity. Accelerated ageing of the braze alloy, feedthroughs and hermetic capsules yielded no evidence of corrosion and no loss of hermeticity. Samples of the gold braze implanted for 15 weeks, in vivo, caused minimal histopathological reaction and results were comparable to those obtained from medical grade silicone controls. The work described represents a first account of a free standing, fully functional hermetic diamond encapsulation for biomedical implants, enabled by gold active alloy brazing and laser micro-machining. Copyright © 2015 Elsevier Ltd. All rights reserved.
Multi-purpose CMOS sensor interface for low-power applications
NASA Astrophysics Data System (ADS)
Wouters, P.; de Cooman, M.; Puers, R.
1994-08-01
A dedicated low-power CMOS transponder microchip is presented as part of a novel telemetry implant for biomedical applications. This mixed analog-digital circuit contains an identification code and collects information on physiological parameters, i.e., body temperature and physical activity, and on the status of the battery. To minimize the amount of data to be transmitted, a dedicated signal processing algorithm is embedded within its circuitry. All telemetry functions (encoding, modulation, generation of the carrier) are implemented on the integrated circuit. Emphasis is on a high degree of flexibility towards sensor inputs and internal data management, extreme miniaturization, and low-power consumption to allow a long implantation lifetime.
Psychiatric Functioning and Quality of Life in Young Patients With Cardiac Rhythm Devices
Panek, Kathryn A.; Labella, Madelyn; Taylor, George Alexander; Gauvreau, Kimberlee; Cecchin, Frank; Martuscello, Maria; Walsh, Edward P.; Berul, Charles I.; DeMaso, David R.
2014-01-01
BACKGROUND: Less is known about depression, anxiety and quality of life (QoL) in children and adolescents with pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs) than is known in adults with these devices. METHODS: A standardized psychiatric interview diagnosed anxiety/depressive disorders in a cross-sectional study. Self-report measures of anxiety, depression and post-traumatic stress disorder were obtained. Medical disease severity, family functioning and QoL data were collected. A total of 166 patients were enrolled (52 ICD, 114 PM; median age 15 years). RESULTS: Prevalence of current and lifetime psychiatric disorders was higher in patients with ICDs than PMs (Current: 27% vs. 11%, P = .02; Lifetime: 52% ICD vs. 34% PM, P = .01). Patients with ICDs had more anxiety than a healthy population (25% vs. 7%, P < .01). Patients with ICDs and PMs had similar levels of depression as a healthy population (ICD 10%, PM 4%, reference 4%, P = .29). In multivariate analysis including a medical disease score, demographics, exposure to beta-blockers, activity limitations, hospitalizations, shocks and procedures, the type of device (PM versus ICD) did not predict psychiatric diagnoses when age at implantation and the severity of medical disease were controlled for. Patients with ICDs and PMs had lower physical QoL scores (ICD 45, PM 47.5, Norm 53, P ≤ .03), but similar psychosocial functioning scores (ICD 49, PM 51, Norm 51, P ≥ .16) versus a normal reference population. CONCLUSIONS: Anxiety is highly prevalent in young patients with ICDs, but the higher rates can be attributed to medical disease severity and age at implantation instead of type of device. PMID:24664095
Advances in Materials for Recent Low-Profile Implantable Bioelectronics
Kim, Yun-Soung; Tillman, Bryan W.; Chun, Youngjae
2018-01-01
The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes. Examples include miniaturized sensors for monitoring intraocular pressure and blood pressure, which are designed in an ultra-thin diaphragm to react with the applied pressure. These sensors are integrated into rigid circuits and multiple modules; this brings challenges regarding the fundamental material’s property mismatch with the targeted human tissues, which are intrinsically soft. Therefore, many polymeric materials have been investigated for hybrid integration with well-characterized functional materials such as silicon membranes and metal interconnects, which enable soft implantable bioelectronics. The most recent trend in implantable systems uses transient materials that naturally dissolve in body fluid after a programmed lifetime. Such biodegradable metallic materials are advantageous in the design of electronics due to their proven electrical properties. Collectively, this review delivers the development history of materials in implantable devices, while introducing new bioelectronics based on bioresorbable materials with multiple functionalities. PMID:29596359
Advances in Materials for Recent Low-Profile Implantable Bioelectronics.
Chen, Yanfei; Kim, Yun-Soung; Tillman, Bryan W; Yeo, Woon-Hong; Chun, Youngjae
2018-03-29
The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes. Examples include miniaturized sensors for monitoring intraocular pressure and blood pressure, which are designed in an ultra-thin diaphragm to react with the applied pressure. These sensors are integrated into rigid circuits and multiple modules; this brings challenges regarding the fundamental material's property mismatch with the targeted human tissues, which are intrinsically soft. Therefore, many polymeric materials have been investigated for hybrid integration with well-characterized functional materials such as silicon membranes and metal interconnects, which enable soft implantable bioelectronics. The most recent trend in implantable systems uses transient materials that naturally dissolve in body fluid after a programmed lifetime. Such biodegradable metallic materials are advantageous in the design of electronics due to their proven electrical properties. Collectively, this review delivers the development history of materials in implantable devices, while introducing new bioelectronics based on bioresorbable materials with multiple functionalities.
Improved lifetime high voltage switch electrode
NASA Astrophysics Data System (ADS)
Halverson, W.
1985-06-01
In this Phase 1 Small Business Innovation Research (SBIR) program, preliminary tests of ion implantation to increase the lifetime of spark switch electrodes have indicated that a 185 keV carbon ion implant into a tungsten-copper composite has reduced electrode erosion by a factor of two to four. Apparently, the thin layer of tungsten carbide (WC) has better thermal properties than pure tungsten; the WC may have penetrated into the unimplanted body of the electrode by liquid and/or solid phase diffusion during erosion testing. These encouraging results should provide the basis for a Phase 2 SBIR program to investigate further the physical and chemical effects of ion implantation on spark gap electrodes and to optimize the technique for applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, K. V. Aneesh, E-mail: aneesh1098@gmail.com; Ravikumar, H. B., E-mail: hbr@physics.uni-mysore.ac.in; Ranganathaiah, C., E-mail: cr@physics.uni-mysore.ac.in
2016-05-06
In order to explore the structural modification induced electrical conductivity, samples of Bakelite Resistive Plate Chamber (RPC) detector materials were exposed to 100 keV Oxygen ion in the fluences of 10{sup 12}, 10{sup 13}, 10{sup 14} and 10{sup 15} ions/cm{sup 2}. Ion implantation induced microstructural changes have been studied using Positron Annihilation Lifetime Spectroscopy (PALS) and X-Ray Diffraction (XRD) techniques. Positron lifetime parameters viz., o-Ps lifetime and its intensity shows the deposition of high energy interior track and chain scission leads to the formation of radicals, secondary ions and electrons at lower ion implantation fluences (10{sup 12} to10{sup 14} ions/cm{supmore » 2}) followed by cross-linking at 10{sup 15} ions/cm{sup 2} fluence due to the radical reactions. The reduction in electrical conductivity of Bakelite detector material is correlated to the conducting pathways and cross-links in the polymer matrix. The appropriate implantation energy and fluence of Oxygen ion on polymer based Bakelite RPC detector material may reduce the leakage current, improves the efficiency, time resolution and thereby rectify the aging crisis of the RPC detectors.« less
Fardal, Øystein; O'Neill, Ciaran; Gjermo, Per; Fardal, Elizabeth; Sandvik, Leiv; Hansen, B Frode; Linden, Gerard J
2012-12-01
Successful periodontal treatment requires a commitment to regular lifelong maintenance and may be perceived by patients to be costly. This study calculates the total lifetime cost of periodontal treatment in the setting of a specialist periodontal practice and investigates the cost implications of choosing not to proceed with such treatment. Data from patients treated in a specialist practice in Norway were used to calculate the total lifetime cost of periodontal treatment that included baseline periodontal treatment, regular maintenance, retreatment, and replacing teeth lost during maintenance. Incremental costs for alternative strategies based on opting to forego periodontal treatment or maintenance and to replace any teeth lost with either bridgework or implants were calculated. Patients who completed baseline periodontal treatment but did not have any additional maintenance or retreatment could replace only three teeth with bridgework or two teeth with implants before the cost of replacing additional teeth would exceed the cost of lifetime periodontal treatment. Patients who did not have any periodontal treatment could replace ≤ 4 teeth with bridgework or implants before a replacement strategy became more expensive. Within the limits of the assumptions made, periodontal treatment in a Norwegian specialist periodontal practice is cost-effective when compared to an approach that relies on opting to replace teeth lost as a result of progressive periodontitis with fixed restorations. In particular, patients who have initial comprehensive periodontal treatment but do not subsequently comply with maintenance could, on average, replace ≤ 3 teeth with bridgework or two teeth with implants before this approach would exceed the direct cost of lifetime periodontal treatment in the setting of the specialist practice studied.
Busse, B; Niecke, M; Püschel, K; Delling, G; Katzer, A; Hahn, M
2007-01-01
Periprosthetic tissue was analysed by the combination of different investigation techniques without destruction. The localisation and geometry of polyethylene abrasion particles were determined quantitatively to differentiate between abrasion due to function and abrasion due to implant loosening. Non-polyethylene particles from implant components which contaminate the tissue were micro-analytically measured. The results will help us to understand loosening mechanisms and thus lead to implant optimisations. A non-destructive particle analysis using highly sensitive proton-induced X-ray emission (PIXE) was developed to achieve a better histological allocation. Five autopsy cases with firmly fitting hip endoprosthesis (2 x Endo-Modell Mark III, 1 x St. Georg Mark II, LINK, Germany; 2 x Spongiosa Metal II, ESKA, Germany) were prepared as ground tissue specimens. Wear investigations were accomplished with a combined application of different microscopic techniques and microanalysis. The abrasion due to implant loosening was histologically evaluated on 293 loosened cup implants (St. Georg Mark II, LINK, Germany). Wear particles are heterogeneously distributed in the soft tissue. In cases of cemented prostheses, cement particles are dominating whereas metal particles could rarely be detected. The concentration of the alloy constituent cobalt (Co) is increased in the mineralised bone tissue. The measured co-depositions depend on the localisation and/or lifetime of an implant. Functional polyethylene (PE) abrasion needs to be differentiated from PE abrasion of another genesis (loosening, impingement) morphologically and by different tissue reactions. In the past a reduction of abrasion was targeted primarily by the optimisation of the bearing surfaces and tribology. The interpretation of our findings indicates that different mechanisms of origin in terms of tissue contamination with wear debris and the alloy should be included in the improvement of implants or implantation techniques.
Neurobiochemical changes in the vicinity of a nanostructured neural implant
NASA Astrophysics Data System (ADS)
Bérces, Zsófia; Tóth, Kinga; Márton, Gergely; Pál, Ildikó; Kováts-Megyesi, Bálint; Fekete, Zoltán; Ulbert, István; Pongrácz, Anita
2016-10-01
Neural interface technologies including recording and stimulation electrodes are currently in the early phase of clinical trials aiming to help patients with spinal cord injuries, degenerative disorders, strokes interrupting descending motor pathways, or limb amputations. Their lifetime is of key importance; however, it is limited by the foreign body response of the tissue causing the loss of neurons and a reactive astrogliosis around the implant surface. Improving the biocompatibility of implant surfaces, especially promoting neuronal attachment and regeneration is therefore essential. In our work, bioactive properties of implanted black polySi nanostructured surfaces (520-800 nm long nanopillars with a diameter of 150-200 nm) were investigated and compared to microstructured Si surfaces in eight-week-long in vivo experiments. Glial encapsulation and local neuronal cell loss were characterised using GFAP and NeuN immunostaining respectively, followed by systematic image analysis. Regarding the severity of gliosis, no significant difference was observed in the vicinity of the different implant surfaces, however, the number of surviving neurons close to the nanostructured surface was higher than that of the microstructured ones. Our results imply that the functionality of implanted microelectrodes covered by Si nanopillars may lead to improved long-term recordings.
Goodman, S. B.; Gibon, E.; Pajarinen, J.; Lin, T.-H.; Keeney, M.; Ren, P.-G.; Nich, C.; Yao, Z.; Egashira, K.; Yang, F.; Konttinen, Y. T.
2014-01-01
Wear particles and by-products from joint replacements and other orthopaedic implants may result in a local chronic inflammatory and foreign body reaction. This may lead to persistent synovitis resulting in joint pain and swelling, periprosthetic osteolysis, implant loosening and pathologic fracture. Strategies to modulate the adverse effects of wear debris may improve the function and longevity of joint replacements and other orthopaedic implants, potentially delaying or avoiding complex revision surgical procedures. Three novel biological strategies to mitigate the chronic inflammatory reaction to orthopaedic wear particles are reported. These include (i) interference with systemic macrophage trafficking to the local implant site, (ii) modulation of macrophages from an M1 (pro-inflammatory) to an M2 (anti-inflammatory, pro-tissue healing) phenotype in the periprosthetic tissues, and (iii) local inhibition of the transcription factor nuclear factor kappa B (NF-κB) by delivery of an NF-κB decoy oligodeoxynucleotide, thereby interfering with the production of pro-inflammatory mediators. These three approaches have been shown to be viable strategies for mitigating the undesirable effects of wear particles in preclinical studies. Targeted local delivery of specific biologics may potentially extend the lifetime of orthopaedic implants. PMID:24478281
A review of acoustic power transfer for bio-medical implants
NASA Astrophysics Data System (ADS)
Basaeri, Hamid; Christensen, David B.; Roundy, Shad
2016-12-01
Bio-implantable devices have been used to perform therapeutic functions such as drug delivery or diagnostic monitoring of physiological parameters. Proper operation of these devices depends on the continuous reliable supply of power. A battery, which is the conventional method to supply energy, is problematic in many of these devices as it limits the lifetime of the implant or dominates the size. In order to power implantable devices, power transfer techniques have been implemented as an attractive alternative to batteries and have received significant research interest in recent years. Acoustic waves are increasingly being investigated as a method for delivering power through human skin and the human body. Acoustic power transfer (APT) has some advantages over other powering techniques such as inductive power transfer and mid range RF power transmission. These advantages include lower absorption in tissue, shorter wavelength enabling smaller transducers, and higher power intensity threshold for safe operation. This paper will cover the basic physics and modeling of APT and will review the current state of acoustic (or ultrasonic) power transfer for biomedical implants. As the sensing and computational elements for biomedical implants are becoming very small, we devote particular attention to the scaling of acoustic and alternative power transfer techniques. Finally, we present current issues and challenges related to the implementation of this technique for powering implantable devices.
MEMS-based power generation techniques for implantable biosensing applications.
Lueke, Jonathan; Moussa, Walied A
2011-01-01
Implantable biosensing is attractive for both medical monitoring and diagnostic applications. It is possible to monitor phenomena such as physical loads on joints or implants, vital signs, or osseointegration in vivo and in real time. Microelectromechanical (MEMS)-based generation techniques can allow for the autonomous operation of implantable biosensors by generating electrical power to replace or supplement existing battery-based power systems. By supplementing existing battery-based power systems for implantable biosensors, the operational lifetime of the sensor is increased. In addition, the potential for a greater amount of available power allows additional components to be added to the biosensing module, such as computational and wireless and components, improving functionality and performance of the biosensor. Photovoltaic, thermovoltaic, micro fuel cell, electrostatic, electromagnetic, and piezoelectric based generation schemes are evaluated in this paper for applicability for implantable biosensing. MEMS-based generation techniques that harvest ambient energy, such as vibration, are much better suited for implantable biosensing applications than fuel-based approaches, producing up to milliwatts of electrical power. High power density MEMS-based approaches, such as piezoelectric and electromagnetic schemes, allow for supplemental and replacement power schemes for biosensing applications to improve device capabilities and performance. In addition, this may allow for the biosensor to be further miniaturized, reducing the need for relatively large batteries with respect to device size. This would cause the implanted biosensor to be less invasive, increasing the quality of care received by the patient.
Identification of vacancy-oxygen complexes in oxygen-implanted silicon probed with slow positrons
NASA Astrophysics Data System (ADS)
Fujinami, M.; Miyagoe, T.; Sawada, T.; Suzuki, R.; Ohdaira, T.; Akahane, T.
2004-04-01
Defects and their annealing behavior for low (2×1015/cm2) and high (1.7×1018/cm2) doses of 180 keV oxygen-implanted silicon have been investigated by the coincidence Doppler broadening (CDB) and lifetime measurements in variable-energy positron annihilation spectroscopy. In the low-dose sample, divacancies are induced throughout the entire implantation region. In the vacancy-oxygen coexisting region (300-500 nm depths), by raising the annealing temperature to 600 °C, vacancy-oxygen VxOy complexes with one vacant site are formed and, simultaneously, the migration of oxygen begins to takes place. In the vacancy-rich region (-200 nm depths), the evolution of simple vacancy clusters to V4 is mainly observed below 600 °C. From CDB and lifetime measurements, it has been proven that after annealing at 800 °C, the VxOy complexes are formed throughout the implanted region and they contain four vacant sites and a high ratio of y to x. On the other hand, high-dose implantation at 550 °C produces the VxOy complexes with a lifetime of a 430 ps in the near-surface region (less than 200 nm deep) and annealing at 1100 °C leads to the highest ratio of y to x. These complexes cannot be annealed out even by annealing at 1350 °C, and their structure is found to be very similar to that for the electron-irradiated amorphous SiO2.
Gekeler, Katrin; Bartz-Schmidt, Karl Ulrich; Sachs, Helmut; MacLaren, Robert E; Stingl, Katarina; Zrenner, Eberhart; Gekeler, Florian
2018-05-01
The purpose of this review is to provide an update on the efforts to restore vision through subretinal implants in patients with degenerative retinal diseases. In addition to the current technique and its latest improvements, it will focus on the surgical technique of implantation as well as explantation and reimplantation. The durability of the current subretinal implant RETINA IMPLANT Alpha AMS has increased substantially compared with the predecessor model RETINA IMPLANT Alpha IMS. According to validated examinations in the laboratory, a median lifetime of 4.7 years will be reached in clinical use; in similar examinations, the previous model has reached only 8 months. Visual function has slightly increased. The surgical technique for subretinal implants is complex and demanding for ophthalmic surgeons, as it is multifaceted and combines novel surgical steps in areas, which are not commonly entered such as the suprachoroidal and the subretinal space. The surgical approach for implantation has matured considerably and has led to successful implantation in 64 patient cases. Surgical challenges are now mainly encountered with the exact subfoveal positioning of the device. The explantation procedure is relatively straight-forward because the implant can be withdrawn in a reverse direction along the already existent subretinal path. Reimplantations, however, are more challenging because some degree of scar tissue may exist along the path of the chip and around the scleral trapdoor. Nevertheless, reimplantations have now been carried out successfully in four patients. The new RETINA IMPLANT Alpha AMS shows significantly improved durability compared with the predecessor model RETINA IMPLANT Alpha IMS. The subretinal implant offers excellent visual results but requires experienced surgeons. Explantation of devices is straight-forward, and reimplantations are challenging but have been successful in four patients.
Method of making silicon on insalator material using oxygen implantation
Hite, Larry R.; Houston, Ted; Matloubian, Mishel
1989-01-01
The described embodiments of the present invention provide a semiconductor on insulator structure providing a semiconductor layer less susceptible to single event upset errors (SEU) due to radiation. The semiconductor layer is formed by implanting ions which form an insulating layer beneath the surface of a crystalline semiconductor substrate. The remaining crystalline semiconductor layer above the insulating layer provides nucleation sites for forming a crystalline semiconductor layer above the insulating layer. The damage caused by implantation of the ions for forming an insulating layer is left unannealed before formation of the semiconductor layer by epitaxial growth. The epitaxial layer, thus formed, provides superior characteristics for prevention of SEU errors, in that the carrier lifetime within the epitaxial layer, thus formed, is less than the carrier lifetime in epitaxial layers formed on annealed material while providing adequate semiconductor characteristics.
Shemtov-Yona, K; Rittel, D
2016-09-01
The fatigue performance of dental implants is usually assessed on the basis of cyclic S/N curves. This neither provides information on the anticipated service performance of the implant, nor does it allow for detailed comparisons between implants unless a thorough statistical analysis is performed, of the kind not currently required by certification standards. The notion of endurance limit is deemed to be of limited applicability, given unavoidable stress concentrations and random load excursions, that all characterize dental implants and their service conditions. We propose a completely different approach, based on random spectrum loading, as long used in aeronautical design. The implant is randomly loaded by a sequence of loads encompassing all load levels it would endure during its service life. This approach provides a quantitative and comparable estimate of its performance in terms of lifetime, based on the very fact that the implant will fracture sooner or later, instead of defining a fatigue endurance limit of limited practical application. Five commercial monolithic Ti-6Al-4V implants were tested under cyclic, and another 5 under spectrum loading conditions, at room temperature and dry air. The failure modes and fracture planes were identical for all implants. The approach is discussed, including its potential applications, for systematic, straightforward and reliable comparisons of various implant designs and environments, without the need for cumbersome statistical analyses. It is believed that spectrum loading can be considered for the generation of new standardization procedures and design applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
MEMS-Based Power Generation Techniques for Implantable Biosensing Applications
Lueke, Jonathan; Moussa, Walied A.
2011-01-01
Implantable biosensing is attractive for both medical monitoring and diagnostic applications. It is possible to monitor phenomena such as physical loads on joints or implants, vital signs, or osseointegration in vivo and in real time. Microelectromechanical (MEMS)-based generation techniques can allow for the autonomous operation of implantable biosensors by generating electrical power to replace or supplement existing battery-based power systems. By supplementing existing battery-based power systems for implantable biosensors, the operational lifetime of the sensor is increased. In addition, the potential for a greater amount of available power allows additional components to be added to the biosensing module, such as computational and wireless and components, improving functionality and performance of the biosensor. Photovoltaic, thermovoltaic, micro fuel cell, electrostatic, electromagnetic, and piezoelectric based generation schemes are evaluated in this paper for applicability for implantable biosensing. MEMS-based generation techniques that harvest ambient energy, such as vibration, are much better suited for implantable biosensing applications than fuel-based approaches, producing up to milliwatts of electrical power. High power density MEMS-based approaches, such as piezoelectric and electromagnetic schemes, allow for supplemental and replacement power schemes for biosensing applications to improve device capabilities and performance. In addition, this may allow for the biosensor to be further miniaturized, reducing the need for relatively large batteries with respect to device size. This would cause the implanted biosensor to be less invasive, increasing the quality of care received by the patient. PMID:22319362
Long-term Calibration Considerations during Subcutaneous Microdialysis Sampling in Mobile Rats
Mou, Xiaodun; Lennartz, Michelle; Loegering, Daniel J.; Stenken, Julie A.
2010-01-01
The level at which implanted sensors and sampling devices maintain their calibration is an important research area. In this work, microdialysis probes with identical geometry and different membranes, polycarbonate/polyether (PC) or polyethersulfone (PES), were used with internal standards (vitamin B12 (MW 1355), antipyrine (MW 188) and 2-deoxyglucose (2-DG, MW 164)) and endogenous glucose to investigate changes in their long-term calibration after implantation into the subcutaneous space of Sprague-Dawley rats. Histological analysis confirmed an inflammatory response to the microdialysis probes and the presence of a collagen capsule. The membrane extraction efficiency (percentage delivered to the tissue space) for antipyrine and 2-DG was not altered throughout the implant lifetime for either PC- or PES-membranes. Yet, Vitamin B12 extraction efficiency and collected glucose concentrations decreased during the implant lifetime. Antipyrine was administered i.v. and its concentrations obtained in both PC-and PES-membrane probes were significantly reduced between the implant day and seven (PC) or 10 (PES) days post implantation suggesting that solute supply is critical for in vivo extraction efficiency. For the low molecular weight solutes such as antipyrine and glucose, localized delivery is not affected by the foreign body reaction, but recovery is significantly reduced. For Vitamin B12, a larger solute, the fibrotic capsule formed around the probe significantly restricts diffusion from the implanted microdialysis probes. PMID:20223515
Xie, Xianzong; Rieth, Loren; Caldwell, Ryan; Diwekar, Mohit; Tathireddy, Prashant; Sharma, Rohit; Solzbacher, Florian
2013-10-01
We present an encapsulation scheme that combines atomic layer deposited (ALD) Al₂O₃ and Parylene C for the encapsulation of implantable devices. The encapsulation performances of combining alumina and Parylene C was compared to individual layers of Parylene C or alumina and the bilayer coating had superior encapsulation properties. The alumina-Parylene coated interdigitated electrodes (IDEs) soaked in PBS for up to nine months at temperatures from 37 to 80 °C for accelerated lifetime testing. For 52-nm alumina and 6-μm Parylene C, leakage current was ∼20 pA at 5 VDC, and the impedance was about 3.5 MΩ at 1 kHz with a phase near -87° from electrochemical impedance spectroscopy for samples soaked at 67 °C for equivalent lifetime of 72 months at 37 °C. The change of impedance during the whole soaking period (up to 70 months of equivalent soaking time at 37 °C) over 1 to 10⁶ Hz was within 5%. The stability of impedance indicated almost no degradation of the encapsulation. Bias voltage effect was studied by continuously applying 5 VDC, and it reduced the lifetime of Parylene coating by ∼75% while it showed no measurable effect on the bilayer coating. Lifetime of encapsulation of IDEs with topography generated by attaching a coil and surface mount device (SMD) capacitor was about half of that of planer IDEs. The stable long-term insulation impedance, low leakage current, and better lifetime under bias voltage and topography made this double-layer encapsulation very promising for chronic implantable devices.
NASA Astrophysics Data System (ADS)
Oliveira, Fernando G.; Ribeiro, Ana R.; Perez, Geronimo; Archanjo, Bráulio S.; Gouvea, Cristol P.; Araújo, Joyce R.; Campos, Andrea P. C.; Kuznetsov, Alexei; Almeida, Clara M.; Maru, Márcia M.; Achete, Carlos A.; Ponthiaux, Pierre; Celis, Jean-Pierre; Rocha, Luis A.
2015-06-01
The growth of the dental implant market increases the concern regarding the quality, efficiency, and lifetime of dental implants. Titanium and its alloys are dominant materials in this field thanks to their high biocompatibility and corrosion resistance, but they possess a very low wear resistance. Besides problems related to osteointegration and bacterial infections, tribocorrosion phenomena being the simultaneous action between corrosion and wear, are likely to occur during the lifetime of the implant. Therefore, tribocorrosion resistant surfaces are needed to guarantee the preservation of dental implants. This work focused on the incorporation of magnesium, together with calcium and phosphorous, in the structure of titanium oxide films produced by micro-arc oxidation (MAO). The characterization of morphology, chemical composition, and crystalline structure of the surfaces provided important insights leading to (1) a better understanding of the oxide film growth mechanisms during the MAO treatment; and (2) a better awareness on the degradation process during tribocorrosion tests. The addition of magnesium was shown to support the formation of rutile which improves the tribocorrosion properties of the surfaces.
Bhardwaj, Upkar; Papadimitrakopoulos, Fotios; Burgess, Diane J.
2008-01-01
A major obstacle to the development of implantable biosensors is the foreign body response (FBR) that results from tissue trauma during implantation and the continuous presence of the implant in the body. The in vivo stability and functionality of biosensors are compromised by damage to sensor components and decreased analyte transport to the sensor. This paper summarizes research undertaken by our group since 2001 to control the FBR toward implanted sensors. Localized and sustained delivery of the anti-inflammatory drug, dexamethasone, and the angiogenic growth factor, vascular endothelial growth factor (VEGF), was utilized to inhibit inflammation as well as fibrosis and provide a stable tissue–device interface without producing systemic adverse effects. The drug-loaded polylactic-co-glycolic acid (PLGA) microspheres were embedded in a polyvinyl alcohol (PVA) hydrogel composite to fabricate a drug-eluting, permeable external coating for implantable devices. The composites were fabricated using the freeze–thaw cycle method and had mechanical properties similar to soft body tissue. Dexamethasone-loaded microsphere/hydrogel composites were able to provide anti-inflammatory protection, preventing the FBR. Moreover, concurrent release of dexamethasone with VEGF induced neoangiogenesis in addition to providing anti-inflammatory protection. Sustained release of dexamethasone is required for the entire sensor lifetime, as a delayed inflammatory response developed after depletion of the drug from the composites. These studies have shown the potential of PLGA microsphere/PVA hydrogel-based composites as drug-eluting external coatings for implantable biosensors. PMID:19885291
Mutual-Information-Based Incremental Relaying Communications for Wireless Biomedical Implant Systems
Liao, Yangzhe; Cai, Qing; Ai, Qingsong; Liu, Quan
2018-01-01
Network lifetime maximization of wireless biomedical implant systems is one of the major research challenges of wireless body area networks (WBANs). In this paper, a mutual information (MI)-based incremental relaying communication protocol is presented where several on-body relay nodes and one coordinator are attached to the clothes of a patient. Firstly, a comprehensive analysis of a system model is investigated in terms of channel path loss, energy consumption, and the outage probability from the network perspective. Secondly, only when the MI value becomes smaller than the predetermined threshold is data transmission allowed. The communication path selection can be either from the implanted sensor to the on-body relay then forwards to the coordinator or from the implanted sensor to the coordinator directly, depending on the communication distance. Moreover, mathematical models of quality of service (QoS) metrics are derived along with the related subjective functions. The results show that the MI-based incremental relaying technique achieves better performance in comparison to our previous proposed protocol techniques regarding several selected performance metrics. The outcome of this paper can be applied to intra-body continuous physiological signal monitoring, artificial biofeedback-oriented WBANs, and telemedicine system design. PMID:29419784
Liao, Yangzhe; Leeson, Mark S; Cai, Qing; Ai, Qingsong; Liu, Quan
2018-02-08
Network lifetime maximization of wireless biomedical implant systems is one of the major research challenges of wireless body area networks (WBANs). In this paper, a mutual information (MI)-based incremental relaying communication protocol is presented where several on-body relay nodes and one coordinator are attached to the clothes of a patient. Firstly, a comprehensive analysis of a system model is investigated in terms of channel path loss, energy consumption, and the outage probability from the network perspective. Secondly, only when the MI value becomes smaller than the predetermined threshold is data transmission allowed. The communication path selection can be either from the implanted sensor to the on-body relay then forwards to the coordinator or from the implanted sensor to the coordinator directly, depending on the communication distance. Moreover, mathematical models of quality of service (QoS) metrics are derived along with the related subjective functions. The results show that the MI-based incremental relaying technique achieves better performance in comparison to our previous proposed protocol techniques regarding several selected performance metrics. The outcome of this paper can be applied to intra-body continuous physiological signal monitoring, artificial biofeedback-oriented WBANs, and telemedicine system design.
Impact of polymer structure and composition on fully resorbable endovascular scaffold performance
Ferdous, Jahid; Kolachalama, Vijaya B.; Shazly, Tarek
2014-01-01
Fully erodible endovascular scaffolds are being increasingly considered for the treatment of obstructive arterial disease owing to their potential to mitigate long-term risks associated with permanent alternatives. While complete scaffold erosion facilitates vessel healing, generation and release of material degradation by-products from candidate materials such as poly-l-lactide (PLLA) may elicit local inflammatory responses that limit implant efficacy. We developed a computational framework to quantify how the compositional and structural parameters of PLLA-based fully erodible endovascular scaffolds affect degradation kinetics, erosion kinetics and the transient accumulation of material by-products within the arterial wall. Parametric studies reveal that, while some material properties have similar effects on these critical processes, others induce qualitatively opposing responses. For example, scaffold degradation is only mildly responsive to changes in either PLLA polydispersity or the initial degree of crystallinity, while the erosion kinetics is comparatively sensitive to crystallinity. Moreover, lactide doping can effectively tune both scaffold degradation and erosion, but a concomitant increase in local byproduct accumulation raises concerns about implant safety. Optimized erodible endovascular scaffolds must precisely balance therapeutic function and biological response over the implant lifetime, where compositional and structural parameters will have differential effects on implant performance. PMID:23261926
NASA Astrophysics Data System (ADS)
Sonnenberg, K.; Antesberger, G.; Brown, B.
1981-12-01
The influence of He on the fatigue properties of stainless steel was investigated using α-particle implantation. The He influence was compared for different external atmospheres (inert, corrosive), various fatigue temperatures (400-750°C), implantation temperatures (400-950°C), He doses (5-3000 ppm), strain amplitudes (0.5-3%) and fatigue frequencies (0.02-8 Hz). In situ and post-implantation fatigue testing showed that the effect of He implantation is very similar in both cases. The effect of He is small if the fatigue temperature is ≤ 600°C. In these cases the fracture mode remains transgranular and only small reductions of the fatigue life (less than a factor of 2) are observed upon He implantation. For higher fatigue temperatures the He causes a transition from a transgranular to an intergranular fracture mode associated with rather dramatic reductions of the fatigue life. It was shown that this fracture mode must be attributed to a growth of He bubbles at the grain boundaries. The growth is probably achieved by condensation of thermal vacancies, the flux of which is controlled by the external stresses and by grain-boundary diffusion. It was found that the size of the lifetime reduction increases with the He dose and the implantation temperature, because more He reaches the grain boundaries. The lifetime depends more strongly on the strain amplitude for irradiated samples. The lifetime for irradiated samples does not depend on the external atmosphere, in contrast to unirradiated samples which have an order of magnitude longer life in the clean atmosphere. In contrast to failure in a transgranular mode, the number of fatigue cycles until feature, N ƒ, is found to decrease with the fatigue frequency in the case of intergranular mode. The temperature above which intergranular fracture occurs (usually above 700°C) is affected by the He dose and the fatigue frequency. For high doses of ≈ 1000 ppm He and small frequencies of ≈0.02 Hz, the intergranular mode is observed as low as 600°C.
Antithrombotic Protein Filter Composed of Hybrid Tissue-Fabric Material has a Long Lifetime.
Inoue, Yusuke; Yokota, Tomoyuki; Sekitani, Tsuyoshi; Kaneko, Akiko; Woo, Taeseong; Kobayashi, Shingo; Shibuya, Tomokazu; Tanaka, Masaru; Kosukegawa, Hiroyuki; Saito, Itsuro; Isoyama, Takashi; Abe, Yusuke; Yambe, Tomoyuki; Someya, Takao; Sekino, Masaki
2017-05-01
There are recent reports of hybrid tissue-fabric materials with good performance-high biocompatibility and high mechanical strength. In this study, we demonstrate the capability of a hybrid material as a long-term filter for blood proteins. Polyester fabrics were implanted into rats to fabricate hybrid tissue-fabric material sheets. The hybrid materials comprised biological tissue grown on the fabric. The materials were extracted from the rat's body, approximately 100 days post-implantation. The tissues were decellularized to prevent immunological rejection. An antithrombogenicity test was performed by dropping blood onto the hybrid material surface. The hybrid material showed lesser blood coagulation than polysulfone and cellulose. Blood plasma was filtered using the hybrid material to evaluate the protein removal percentage and the lifetime of the hybrid material in vitro. The hybrid material showed a comparable performance to conventional filters for protein removal. Moreover, the hybrid material could work as a protein filter for 1 month, which is six times the lifetime of polysulfone.
Positron annihilation lifetime spectroscopy study of Kapton thin foils
NASA Astrophysics Data System (ADS)
Kanda, G. S.; Ravelli, L.; Löwe, B.; Egger, W.; Keeble, D. J.
2016-01-01
Variable energy positron annihilation lifetime spectroscopy (VE-PALS) experiments on polyimide material Kapton are reported. Thin Kapton foils are widely used in a variety of mechanical, electronic applications. PALS provides a sensitive probe of vacancy-related defects in a wide range of materials, including open volume in polymers. Varying the positron implantation energy enables direct measurement of thin foils. Thin Kapton foils are also commonly used to enclose the positron source material in conventional PALS measurements performed with unmoderated radionuclide sources. The results of depth-profiled positron lifetime measurements on 7.6 μm and 25 μm Kapton foils are reported and determine a dominant 385(1) ps lifetime component. The absence of significant nanosecond lifetime component due to positronium formation is confirmed.
R&D on dental implants breakage
NASA Astrophysics Data System (ADS)
Croitoru, Sorin Mihai; Popovici, Ion Alexandru
2017-09-01
Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.
Farhadi, Rozita; Farhadi, Bita
2014-01-01
Power transistors, such as the vertical, double-diffused, metal-oxide semiconductor (VDMOS), are used extensively in the amplifier circuits of medical devices. The aim of this research was to construct a VDMOS power transistor with an optimized structure to enhance the operation of medical devices. First, boron was implanted in silicon by implanting unclamped inductive switching (UIS) and a Faraday shield. The Faraday shield was implanted in order to replace the gate-field parasitic capacitor on the entry part of the device. Also, implanting the UIS was used in order to decrease the effect of parasitic bipolar junction transistor (BJT) of the VDMOS power transistor. The research tool used in this study was Silvaco software. By decreasing the transistor entry resistance in the optimized VDMOS structure, power losses and noise at the entry of the transistor were decreased, and, by increasing the breakdown voltage, the lifetime of the VDMOS transistor lifetime was increased, which resulted in increasing drain flow and decreasing Ron. This consequently resulted in enhancing the operation of high-frequency medical devices that use transistors, such as Radio Frequency (RF) and electrocardiograph machines. PMID:25763152
Farhadi, Rozita; Farhadi, Bita
2014-01-01
Power transistors, such as the vertical, double-diffused, metal-oxide semiconductor (VDMOS), are used extensively in the amplifier circuits of medical devices. The aim of this research was to construct a VDMOS power transistor with an optimized structure to enhance the operation of medical devices. First, boron was implanted in silicon by implanting unclamped inductive switching (UIS) and a Faraday shield. The Faraday shield was implanted in order to replace the gate-field parasitic capacitor on the entry part of the device. Also, implanting the UIS was used in order to decrease the effect of parasitic bipolar junction transistor (BJT) of the VDMOS power transistor. The research tool used in this study was Silvaco software. By decreasing the transistor entry resistance in the optimized VDMOS structure, power losses and noise at the entry of the transistor were decreased, and, by increasing the breakdown voltage, the lifetime of the VDMOS transistor lifetime was increased, which resulted in increasing drain flow and decreasing Ron. This consequently resulted in enhancing the operation of high-frequency medical devices that use transistors, such as Radio Frequency (RF) and electrocardiograph machines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, SH.; Ballmann, C.; Quarles, C. A.
2009-03-10
The application of positron annihilation lifetime spectroscopy (PALS) and Doppler broadening spectroscopy (DBS) to the study of animal or human tissue has only recently been reported [G. Liu, et al. phys. stat. sol. (C) 4, Nos. 10, 3912-3915 (2007)]. We have initiated a study of normal brain section and brain section with glioma derived from a rat glioma model. For the rat glioma model, 200,000 C6 cells were implanted in the basal ganglion of adult Sprague Dawley rats. The rats were sacrificed at 21 days after implantation. The brains were harvested, sliced into 2 mm thick coronal sections, and fixedmore » in 4% formalin. PALS lifetime runs were made with the samples soaked in formalin, and there was not significant evaporation of formalin during the runs. The lifetime spectra were analyzed into two lifetime components. While early results suggested a small decrease in ortho-Positronium (o-Ps) pickoff lifetime between the normal brain section and brain section with glioma, further runs with additional samples have showed no statistically significant difference between the normal and tumor tissue for this type of tumor. The o-Ps lifetime in formalin alone was lower than either the normal tissue or glioma sample. So annihilation in the formalin absorbed in the samples would lower the o-Ps lifetime and this may have masked any difference due to the glioma itself. DBS was also used to investigate the difference in positronium formation between tumor and normal tissue. Tissue samples are heterogeneous and this needs to be carefully considered if PALS and DBS are to become useful tools in distinguishing tissue samples.« less
Positron and nanoindentation study of helium implanted high chromium ODS steels
NASA Astrophysics Data System (ADS)
Veternikova, Jana Simeg; Fides, Martin; Degmova, Jarmila; Sojak, Stanislav; Petriska, Martin; Slugen, Vladimir
2017-12-01
Three oxide dispersion strengthened (ODS) steels with different chromium content (MA 956, MA 957 and ODM 751) were studied as candidate materials for new nuclear reactors in term of their radiation stability. The radiation damage was experimentally simulated by helium ion implantation with energy of ions up to 500 keV. The study was focused on surface and sub-surface structural change due to the ion implantation observed by mostly non-destructive techniques: positron annihilation lifetime spectroscopy and nanoindentation. The applied techniques demonstrated the best radiation stability of the steel ODM 751. Blistering effect occurred due to high implantation dose (mostly in MA 956) was studied in details.
Xie, Xianzong; Rieth, Loren; Merugu, Srinivas; Tathireddy, Prashant; Solzbacher, Florian
2012-08-27
Encapsulation of biomedical implants with complex three dimensional geometries is one of the greatest challenges achieving long-term functionality and stability. This report presents an encapsulation scheme that combines Al(2)O(3) by atomic layer deposition with parylene C for implantable electronic systems. The Al(2)O(3)-parylene C bi-layer was used to encapsulate interdigitated electrodes, which were tested invitro by soak testing in phosphate buffered saline solution at body temperature (37 °C) and elevated temperatures (57 °C and 67 °C) for accelerated lifetime testing up to 5 months. Leakage current and electrochemical impedance spectroscopy were measured for evaluating the integrity and insulation performance of the coating. Leakage current was stably about 15 pA at 5 V dc, and impedance was constantly about 3.5 MΩ at 1 kHz by using electrochemical impedance spectroscopy for samples under 67 °C about 5 months (approximately equivalent to 40 months at 37 °C). Alumina and parylene coating lasted at least 3 times longer than parylene coated samples tested at 80 °C. The excellent insulation performance of the encapsulation shows its potential usefulness for chronic implants.
Chandrappan, Jayakrishnan; Murray, Matthew; Kakkar, Tarun; Petrik, Peter; Agocs, Emil; Zolnai, Zsolt; Steenson, D.P.; Jha, Animesh; Jose, Gin
2015-01-01
Chemical dissimilarity of tellurium oxide with silica glass increases phase separation and crystallization tendency when mixed and melted for making a glass. We report a novel technique for incorporating an Er3+-doped tellurite glass composition into silica substrates through a femtosecond (fs) laser generated plasma assisted process. The engineered material consequently exhibits the spectroscopic properties of Er3+-ions, which are unachievable in pure silica and implies this as an ideal material for integrated photonics platforms. Formation of a well-defined metastable and homogeneous glass structure with Er3+-ions in a silica network, modified with tellurite has been characterized using high-resolution cross-sectional transmission electron microscopy (HRTEM). The chemical and structural analyses using HRTEM, Rutherford backscattering spectrometry (RBS) and laser excitation techniques, confirm that such fs-laser plasma implanted glasses may be engineered for significantly higher concentration of Er3+-ions without clustering, validated by the record high lifetime-density product 0.96 × 1019 s.cm−3. Characterization of planar optical layers and photoluminescence emission spectra were undertaken to determine their thickness, refractive indices and photoluminescence properties, as a function of Er3+ concentration via different target glasses. The increased Er3+ content in the target glass enhance the refractive index and photoluminescence intensity of the modified silica layer whilst the lifetime and thickness decrease. PMID:26370060
The impact of diamond nanocrystallinity on osteoblast functions.
Yang, Lei; Sheldon, Brian W; Webster, Thomas J
2009-07-01
Nanocrystalline diamond has been proposed as an anti-abrasive film on orthopedic implants. In this study, osteoblast (bone forming cells) functions including adhesion (up to 4h), proliferation (up to 5 days) and differentiation (up to 21 days) on different diamond film topographies were systematically investigated. In order to exclude interferences from changes in surface chemistry and wettability (energy), diamond films with nanometer and micron scale topographies were fabricated through microwave plasma enhanced chemical-vapor-deposition and hydrogen plasma treatment. Scanning electron microscopy (SEM), atomic force microscopy (AFM), Raman spectroscopy and water contact angle measurements verified the similar surface chemistry and wettability but varied topographies for all of the diamond films prepared on silicon in this study. Cytocompatibility assays demonstrated enhanced osteoblast functions (including adhesion, proliferation, intracellular protein synthesis, alkaline phosphatase activity and extracellular calcium deposition) on nanocrystalline diamond compared to submicron diamond grain size films for all time periods tested up to 21 days. An SEM study of osteoblast attachment helped to explain the topographical impact diamond had on osteoblast functions by showing altered filopodia extensions on the different diamond topographies. In summary, these results provided insights into understanding the role diamond nanotopography had on osteoblast interactions and more importantly, the application of diamond films to improve orthopedic implant lifetimes.
Minnikanti, Saugandhika; Diao, Guoqing; Pancrazio, Joseph J; Xie, Xianzong; Rieth, Loren; Solzbacher, Florian; Peixoto, Nathalia
2014-02-01
The lifetime and stability of insulation are critical features for the reliable operation of an implantable neural interface device. A critical factor for an implanted insulation's performance is its barrier properties that limit access of biological fluids to the underlying device or metal electrode. Parylene C is a material that has been used in FDA-approved implantable devices. Considered a biocompatible polymer with barrier properties, it has been used as a substrate, insulation or an encapsulation for neural implant technology. Recently, it has been suggested that a bilayer coating of Parylene C on top of atomic-layer-deposited Al2O3 would provide enhanced barrier properties. Here we report a comprehensive study to examine the mean time to failure of Parylene C and Al2O3-Parylene C coated devices using accelerated lifetime testing. Samples were tested at 60°C for up to 3 months while performing electrochemical measurements to characterize the integrity of the insulation. The mean time to failure for Al2O3-Parylene C was 4.6 times longer than Parylene C coated samples. In addition, based on modeling of the data using electrical circuit equivalents, we show here that there are two main modes of failure. Our results suggest that failure of the insulating layer is due to pore formation or blistering as well as thinning of the coating over time. The enhanced barrier properties of the bilayer Al2O3-Parylene C over Parylene C makes it a promising candidate as an encapsulating neural interface. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
2013-03-01
characterization and toward future intravital studies. Preliminary fluorescence lifetime images were also collected intravitally through a mammary imaging window...intend to use this characterization to understand shifts in fluorescence lifetime collected by intravital imaging using a mammary imaging window...collected intravitally through a mammary imaging window implanted in a female, PyVT positive, Col1a1 heterozygote, mouse (Figure 7). A paper has
NASA Technical Reports Server (NTRS)
Watanabe, M.; Actor, G.; Gatos, H. C.
1977-01-01
Quantitative analysis of the electron beam induced current in conjunction with high-resolution scanning makes it possible to evaluate the minority-carrier lifetime three dimensionally in the bulk and the surface recombination velocity two dimensionally, with a high spacial resolution. The analysis is based on the concept of the effective excitation strength of the carriers which takes into consideration all possible recombination sources. Two-dimensional mapping of the surface recombination velocity of phosphorus-diffused silicon diodes is presented as well as a three-dimensional mapping of the changes in the minority-carrier lifetime in ion-implanted silicon.
NASA Astrophysics Data System (ADS)
Thompson, M.; Drummond, D.; Sullivan, J.; Elliman, R.; Kluth, P.; Kirby, N.; Riley, D.; Corr, C. S.
2018-06-01
To determine the effect of pre-existing defects on helium-vacancy cluster nucleation and growth, tungsten samples were self-implanted with 1 MeV tungsten ions at varying fluences to induce radiation damage, then subsequently exposed to helium plasma in the MAGPIE linear plasma device. Positron annihilation lifetime spectroscopy was performed both immediately after self-implantation, and again after plasma exposure. After self-implantation vacancies clusters were not observed near the sample surface (<30 nm). At greater depths (30–150 nm) vacancy clusters formed, and were found to increase in size with increasing W-ion fluence. After helium plasma exposure in the MAGPIE linear plasma device at ~300 K with a fluence of 1023 He-m‑2, deep (30–150 nm) vacancy clusters showed similar positron lifetimes, while shallow (<30 nm) clusters were not observed. The intensity of positron lifetime signals fell for most samples after plasma exposure, indicating that defects were filling with helium. The absence of shallow clusters indicates that helium requires pre-existing defects in order to drive vacancy cluster growth at 300 K. Further samples that had not been pre-damaged with W-ions were also exposed to helium plasma in MAGPIE across fluences from 1 × 1022 to 1.2 × 1024 He-m‑2. Samples exposed to fluences up to 1 × 1023 He-m‑2 showed no signs of damage. Fluences of 5 × 1023 He-m‑2 and higher showed significant helium-cluster formation within the first 30 nm, with positron lifetimes in the vicinity 0.5–0.6 ns. The sample temperature was significantly higher for these higher fluence exposures (~400 K) due to plasma heating. This higher temperature likely enhanced bubble formation by significantly increasing the rate interstitial helium clusters generate vacancies, which is we suspect is the rate-limiting step for helium-vacancy cluster/bubble nucleation in the absence of pre-existing defects.
Bayliss, Lee E; Culliford, David; Monk, A Paul; Glyn-Jones, Sion; Prieto-Alhambra, Daniel; Judge, Andrew; Cooper, Cyrus; Carr, Andrew J; Arden, Nigel K; Beard, David J; Price, Andrew J
2017-04-08
Total joint replacements for end-stage osteoarthritis of the hip and knee are cost-effective and demonstrate significant clinical improvement. However, robust population based lifetime-risk data for implant revision are not available to aid patient decision making, which is a particular problem in young patient groups deciding on best-timing for surgery. We did implant survival analysis on all patients within the Clinical Practice Research Datalink who had undergone total hip replacement or total knee replacement. These data were adjusted for all-cause mortality with data from the Office for National Statistics and used to generate lifetime risks of revision surgery based on increasing age at the time of primary surgery. We identified 63 158 patients who had undergone total hip replacement and 54 276 who had total knee replacement between Jan 1, 1991, and Aug 10, 2011, and followed up these patients to a maximum of 20 years. For total hip replacement, 10-year implant survival rate was 95·6% (95% CI 95·3-95·9) and 20-year rate was 85·0% (83·2-86·6). For total knee replacement, 10-year implant survival rate was 96·1% (95·8-96·4), and 20-year implant survival rate was 89·7% (87·5-91·5). The lifetime risk of requiring revision surgery in patients who had total hip replacement or total knee replacement over the age of 70 years was about 5% with no difference between sexes. For those who had surgery younger than 70 years, however, the lifetime risk of revision increased for younger patients, up to 35% (95% CI 30·9-39·1) for men in their early 50s, with large differences seen between male and female patients (15% lower for women in same age group). The median time to revision for patients who had surgery younger than age 60 was 4·4 years. Our study used novel methodology to investigate and offer new insight into the importance of young age and risk of revision after total hip or knee replacement. Our evidence challenges the increasing trend for more total hip replacements and total knee replacements to be done in the younger patient group, and these data should be offered to patients as part of the shared decision making process. Oxford Musculoskeletal Biomedical Research Unit, National Institute for Health Research. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.
Positronium formation in SiO2 films grown on Si substrates studied by monoenergetic positron beams
NASA Astrophysics Data System (ADS)
Uedono, A.; Wei, L.; Tanigawa, S.; Suzuki, R.; Ohgaki, H.; Mikado, T.; Kawano, T.; Ohji, Y.
1994-04-01
The annihilation characteristics of positrons in SiO2 films grown on Si substrates were studied by using monoenergetic positron beams. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured as a function of incident positron energy for SiO2 (166 nm)/Si specimens fabricated by thermal oxidation. From the measurements, it was found that about 90% of positrons implanted into the SiO2 film annihilate from positronium (Ps) states. This fact was due to the trapping of positrons by open-space defects and a resultant enhanced formation of Ps in such regions. For the SiO2 film grown at 650 °C, the lifetime of ortho-Ps was found to be shorter than that in the film grown at 1000 °C. This result suggests that the volume of open-space defects in the SiO2 film decreased with decreasing the growth rate of the SiO2 film.
Bažant, Zdeněk P.; Le, Jia-Liang; Bazant, Martin Z.
2009-01-01
The failure probability of engineering structures such as aircraft, bridges, dams, nuclear structures, and ships, as well as microelectronic components and medical implants, must be kept extremely low, typically <10−6. The safety factors needed to ensure it have so far been assessed empirically. For perfectly ductile and perfectly brittle structures, the empirical approach is sufficient because the cumulative distribution function (cdf) of random material strength is known and fixed. However, such an approach is insufficient for structures consisting of quasibrittle materials, which are brittle materials with inhomogeneities that are not negligible compared with the structure size. The reason is that the strength cdf of quasibrittle structure varies from Gaussian to Weibullian as the structure size increases. In this article, a recently proposed theory for the strength cdf of quasibrittle structure is refined by deriving it from fracture mechanics of nanocracks propagating by small, activation-energy-controlled, random jumps through the atomic lattice. This refinement also provides a plausible physical justification of the power law for subcritical creep crack growth, hitherto considered empirical. The theory is further extended to predict the cdf of structural lifetime at constant load, which is shown to be size- and geometry-dependent. The size effects on structure strength and lifetime are shown to be related and the latter to be much stronger. The theory fits previously unexplained deviations of experimental strength and lifetime histograms from the Weibull distribution. Finally, a boundary layer method for numerical calculation of the cdf of structural strength and lifetime is outlined. PMID:19561294
Enhancing the Performance of Medical Implant Communication Systems through Cooperative Diversity
Hegyi, Barnabás; Levendovszky, János
2010-01-01
Battery-operated medical implants—such as pacemakers or cardioverter-defibrillators—have already been widely used in practical telemedicine and telecare applications. However, no solution has yet been found to mitigate the effect of the fading that the in-body to off-body communication channel is subject to. In this paper, we reveal and assess the potential of cooperative diversity to combat fading—hence to improve system performance—in medical implant communication systems. In the particular cooperative communication scenario we consider, multiple cooperating receiver units are installed across the room accommodating the patient with a medical implant inside his/her body. Our investigations have shown that the application of cooperative diversity is a promising approach to enhance the performance of medical implant communication systems in various aspects such as implant lifetime and communication link reliability. PMID:20379346
Ion-Doped Silicate Bioceramic Coating of Ti-Based Implant
Mohammadi, Hossein; Sepantafar, Mohammadmajid
2016-01-01
Titanium and its alloy are known as important load-bearing biomaterials. The major drawbacks of these metals are fibrous formation and low corrosion rate after implantation. The surface modification of biomedical implants through various methods such as plasma spray improves their osseointegration and clinical lifetime. Different materials have been already used as coatings on biomedical implant, including calcium phosphates and bioglass. However, these materials have been reported to have limited clinical success. The excellent bioactivity of calcium silicate (Ca-Si) has been also regarded as coating material. However, their high degradation rate and low mechanical strength limit their further coating application. Trace element modification of (Ca-Si) bioceramics is a promising method, which improves their mechanical strength and chemical stability. In this review, the potential of trace element-modified silicate coatings on better bone formation of titanium implant is investigated. PMID:26979401
Erbium-implanted silica colloids with 80% luminescence quantum efficiency
NASA Astrophysics Data System (ADS)
Slooff, L. H.; de Dood, M. J. A.; van Blaaderen, A.; Polman, A.
2000-06-01
Silica colloids with a diameter of 240-360 nm, grown by wet chemical synthesis using ethanol, ammonia, water, and tetraethoxysilane, were implanted with 350 keV Er ions, to peak concentrations of 0.2-1.1 at. % and put onto a silicon or glass substrate. After annealing at 700-900 °C the colloids show clear room-temperature photoluminescence at 1.53 μm, with lifetimes as high as 17 ms. By comparing data of different Er concentrations, the purely radiative lifetime is estimated to be 20-22 ms, indicating a high quantum efficiency of about 80%. This high quantum efficiency indicates that, after annealing, the silica colloids are almost free of OH impurities. Spinning a layer of polymethylmethacrylate over the silica spheres results in an optically transparent nanocomposite layer, that can be used as a planar optical waveguide amplifier at 1.5 μm that is fully compatible with polymer technology.
Parylene-on-oil packaging for long-term implantable pressure sensors.
Shapero, Aubrey M; Liu, Yang; Tai, Yu-Chong
2016-08-01
This paper reports and analyzes the feasibility study of a parylene-on-oil encapsulation packaging method of pressure sensors targeted for long-term implantation. Commercial barometric digital-output pressure sensors are enclosed in silicone oil and then encapsulated in situ with parylene-C or -D (PA-C, PA-D) chemical vapor deposition. Experimentally, sensors encapsulated with 30,000 cSt silicone oil and 27 μm PA-D show good performance for 6 weeks in 77 °C saline with >99 % of original sensitivity, corresponding to an extrapolated lifetime of around 21 months in 37 °C saline. This work shows that, with proper designs, such a packaging method can preserve the original pressure sensor sensitivity without offset, validated throughout accelerated lifetime tests. In experiments, wires on the prototypes are used for external electronics but it is found that they contributed to early failures, which would be absent in real wireless versions, indicating a potential for even longer lifetimes. Finally, a verified model is presented to predict the pressure sensor sensitivity of parylene-on-oil packaging with and without the presence of a bubble in the oil.
A Percutaneously Implantable Fetal Pacemaker
Zhou, Li; Vest, Adriana N.; Chmait, Ramen H.; Bar-Cohen, Yaniv; Pruetz, Jay; Silka, Michael; Zheng, Kaihui; Peck, Ray; Loeb, Gerald E.
2015-01-01
A miniaturized, self-contained pacemaker that could be implanted with a minimally invasive technique would dramatically improve the survival rate for fetuses that develop hydrops fetalis as a result of congenital heart block. We are currently validating a device that we developed to address this bradyarrhythmia. Preclinical studies in a fetal sheep model are underway to demonstrate that the device can be implanted via a minimally invasive approach, can mechanically withstand the harsh bodily environment, can induce effective contractions of the heart muscle with an adequate safety factor, and can successfully operate for the required device lifetime of three months using the previously-developed closed loop transcutaneous recharging system. PMID:25570982
Power harvesting using PZT ceramics embedded in orthopedic implants.
Chen, Hong; Liu, Ming; Jia, Chen; Wang, Zihua
2009-09-01
Battery lifetime has been the stumbling block for many power-critical or maintenance-free real-time embedded applications, such as wireless sensors and orthopedic implants. Thus a piezoelectric material that could convert human motion into electrical energy provides a very attractive solution for clinical implants. In this work, we analyze the power generation characteristics of stiff lead zirconate titanate (PZT) ceramics and the equivalent circuit through extensive experiments. Our experimental framework allows us to explore many important design considerations of such a PZT-based power generator. Overall we can achieve a PZT element volume of 0.5 x 0.5 x 1.8 cm, which is considerably smaller than the results reported so far. Finally, we outline the application of our PZT elements in a total knee replacement (TKR) implant.
Long-Term Production and Delivery of Human Growth Hormone In vivo
NASA Astrophysics Data System (ADS)
Heartlein, Michael W.; Roman, Victoria A.; Jiang, Ji-Lei; Sellers, Joan W.; Zuliani, Antoinette M.; Treco, Douglas A.; Selden, Richard F.
1994-11-01
The application of somatic cell gene therapy to large patient populations will require the development of safe and practical approaches to the generation and characterization of genetically manipulated cells. Transkaryotic implantation is a gene therapy system based on the production of clonal strains of engineered primary and secondary cells, using nonviral methods. We demonstrate here that, on implantation, these clonal cell strains stably and reproducibly deliver pharmacologic quantities of protein for the lifetime of the experimental animals.
Endocardial Energy Harvesting by Electromagnetic Induction.
Zurbuchen, Adrian; Haeberlin, Andreas; Bereuter, Lukas; Pfenniger, Alois; Bosshard, Simon; Kernen, Micha; Philipp Heinisch, Paul; Fuhrer, Juerg; Vogel, Rolf
2018-02-01
cardiac pacemakers require regular medical follow-ups to ensure proper functioning. However, device replacements due to battery depletion are common and account for ∼25% of all implantation procedures. Furthermore, conventional pacemakers require pacemaker leads which are prone to fractures, dislocations or isolation defects. The ensuing surgical interventions increase risks for the patients and costs that need to be avoided. in this study, we present a method to harvest energy from endocardial heart motions. We developed a novel generator, which converts the heart's mechanical into electrical energy by electromagnetic induction. A mathematical model has been introduced to identify design parameters strongly related to the energy conversion efficiency of heart motions and fit the geometrical constraints for a miniaturized transcatheter deployable device. The implemented final design was tested on the bench and in vivo. the mathematical model proved an accurate method to estimate the harvested energy. For three previously recorded heart motions, the model predicted a mean output power of 14.5, 41.9, and 16.9 μW. During an animal experiment, the implanted device harvested a mean output power of 0.78 and 1.7 μW at a heart rate of 84 and 160 bpm, respectively. harvesting kinetic energy from endocardial motions seems feasible. Implanted at an energetically favorable location, such systems might become a welcome alternative to extend the lifetime of cardiac implantable electronic device. the presented endocardial energy harvesting concept has the potential to turn pacemakers into battery- and leadless systems and thereby eliminate two major drawbacks of contemporary systems.
Wireless implantable electronic platform for chronic fluorescent-based biosensors.
Valdastri, Pietro; Susilo, Ekawahyu; Förster, Thilo; Strohhöfer, Christof; Menciassi, Arianna; Dario, Paolo
2011-06-01
The development of a long-term wireless implantable biosensor based on fluorescence intensity measurement poses a number of technical challenges, ranging from biocompatibility to sensor stability over time. One of these challenges is the design of a power efficient and miniaturized electronics, enabling the biosensor to move from bench testing to long term validation, up to its final application in human beings. In this spirit, we present a wireless programmable electronic platform for implantable chronic monitoring of fluorescent-based autonomous biosensors. This system is able to achieve extremely low power operation with bidirectional telemetry, based on the IEEE802.15.4-2003 protocol, thus enabling over three-year battery lifetime and wireless networking of multiple sensors. During the performance of single fluorescent-based sensor measurements, the circuit drives a laser diode, for sensor excitation, and acquires the amplified signals from four different photodetectors. In vitro functionality was preliminarily tested for both glucose and calcium monitoring, simply by changing the analyte-binding protein of the biosensor. Electronics performance was assessed in terms of timing, power consumption, tissue exposure to electromagnetic fields, and in vivo wireless connectivity. The final goal of the presented platform is to be integrated in a complete system for blood glucose level monitoring that may be implanted for at least one year under the skin of diabetic patients. Results reported in this paper may be applied to a wide variety of biosensors based on fluorescence intensity measurement.
Robustness up to 400°C of the passivation of c-Si by p-type a-Si:H thanks to ion implantation
NASA Astrophysics Data System (ADS)
Defresne, A.; Plantevin, O.; Roca i Cabarrocas, Pere
2016-12-01
Heterojunction solar cells based on crystalline silicon (c-Si) passivated by hydrogenated amorphous silicon (a-Si:H) thin films are one of the most promising architectures for high energy conversion efficiency. Indeed, a-Si:H thin films can passivate both p-type and n-type wafers and can be deposited at low temperature (<200°C) using PECVD. However, such passivation layers, in particular p-type a-Si:H, show a dramatic degradation in passivation quality above 200°C. Yet, annealing at 300 - 400°C the TCO layer and metallic contacts is highly desirable to reduce the contact resistance as well as the TCO optical absorption. In this work, we show that as expected, ion implantation (5 - 30 keV) introduces defects at the c-Si/a-Si:H interface which strongly degrade the effective lifetime, down to a few micro-seconds. However, the passivation quality can be restored and lifetime values can be improved up to 2 ms over the initial value with annealing. We show here that effective lifetimes above 1 ms can be maintained up to 380°C, opening up the possibility for higher process temperatures in silicon heterojunction device fabrication.
De Vries, N E; Laurendeau, C; Lafuma, A; Berdeaux, G; Nuijts, R M M A
2010-04-01
To estimate the lifetime cost consequences for society and the National Health Service (NHS) of bilateral monofocal (SI40NB) or multifocal (ReSTOR or Array-SA40) intraocular lense (IOL) implantation after cataract surgery. Public hospital in the Netherlands. A Markov model simulated three cohorts of patients followed 69 until 100 years of age, or death. Spectacle independence rates for each IOL were adjusted to the results of a randomized clinical trial that compared monofocal and multifocal Array-SA40 IOL implants, together with a prospective cohort of patients implanted with ReSTOR. Adjustment was performed using the propensity score method in a multivariate analysis. Resource consumption was estimated from a dedicated Dutch survey. Dutch unit costs were applied to spectacles, cataract surgery, IOLs, visits to ophthalmologists, optometrists, transport, and spectacle cleaning materials. Cost discounted at 4% and undiscounted economic results were calculated. Spectacle independence rates were 86.0% for ReSTOR, 8.7% for monofocal IOLs, and 8.5% for Array-SA40. Patients lived without needing spectacles for 12.9 years after ReSTOR, for 1.4 years after monofocal IOLs, and 1.3 years after Array-SA40. ReSTOR patients bought 6.4 fewer pairs of spectacles than monofocal patients. Lifetime discounted cost consequences for the society were ReSTOR euro3969, monofocal IOLs euro4123, and Array-SA40 euro5326. Corresponding costs for the NHS were euro2415, euro2555, and euro2556, respectively. ReSTOR IOLs provided higher levels of spectacle independence than monofocal SI40NB or multifocal Array-SA40 IOLs resulting in savings, compared to a monofocal, over the period modelled of euro315 for society and euro140 for the NHS.
External unit for a semi-implantable middle ear hearing device.
Garverick, S L; Kane, M; Ko, W H; Maniglia, A J
1997-06-01
A miniaturized, low-power external unit has been developed for the clinical trials of a semi-implantable middle ear electromagnetic hearing device (SIMEHD) which uses radio-frequency telemetry to couple sound signals to the internal unit. The external unit is based on a commercial hearing aid which provides proven audio amplification and compression. Its receiver is replaced by an application-specific integrated circuit (ASIC) which: 1) adjusts the direct-current bias of the audio input according to its peak value; 2) converts the audio signal to a one-bit digital form using sigma-delta modulation; 3) modulates the sigma-delta output with a radio-frequency (RF) oscillator; and 4) drives the external RF coil and tuning capacitor using a field-effect transistor operated in class D. The external unit functions as expected and has been used to operate bench-top tests to the SIMEHD. Measured current consumption is 1.65-2.15 mA, which projects to a battery lifetime of about 15 days. Bandwidth is 6 kHz and harmonic distortion is about 2%.
Effects of impurities on the biodegradation behavior of pure magnesium
NASA Astrophysics Data System (ADS)
Lee, Ji-Young; Han, Gilsoo; Kim, Yu-Chan; Byun, Ji-Young; Jang, Jae-il; Seok, Hyun-Kwang; Yang, Seok-Jo
2009-12-01
The corrosion behavior of pure magnesium that has different content ratio of impurities (such as Fe/Mn ratio) in Hanks' solution was investigated in order to tailor the lifetime of biodegradable implant made of pure magnesium. Two distinct stages of corrosion were observed: a slow corrosion rate stage and a subsequent fast corrosion rate stage. The first stage was characterized by uniform corrosion that produced magnesium hydroxide and calcium phosphate film on a magnesium surface, resulting in a slow corrosion rate. The second stage with an abrupt increase in the corrosion rate was induced by Fe precipitates and was stimulated by an increase in the Fe/Mn ratio. This corrosion was developed to a preferred crystallographic pitting corrosion where the pits propagated along the preferred crystallographic plane and several layers of Mg planes with narrow interplanar space remained uncorroded. From this study, it is expected that the lifetime of the biodegradable implant made of pure Mg can be tailored by controlling the amount and ratio of the impurities.
Harrison, Noel; Field, John R; Quondamatteo, Fabio; Curtin, William; McHugh, Peter E; Mc Donnell, Pat
2014-09-01
A new surface architecture for cementless orthopaedic implants (OsteoAnchor), which incorporates a multitude of tiny anchor features for enhancing primary fixation, was tested in an ovine hemi-arthroplasty pilot study. Test animals were implanted with a hip stem component incorporating the OsteoAnchor surface architecture produced using additive layer manufacturing and control animals were implanted with stems containing a standard plasma sprayed titanium coating. Intra-operative surgeon feedback indicated that superior primary fixation was achieved for the OsteoAnchor stems and rapid return to normal gait and load bearing was observed post-operation. Following a 16-week recovery time, histological evaluation of the excised femurs revealed in-growth of healthy bone into the porous structure of the OsteoAnchor stems. Bone in-growth was not achieved for the plasma sprayed stems. These results indicate the potential for the OsteoAnchor surface architecture to enhance both the initial stability and long term lifetime of cementless orthopaedic implants. Copyright © 2014 Elsevier Ltd. All rights reserved.
Tam, Derrick Y; Hughes, Avery; Fremes, Stephen E; Youn, Saerom; Hancock-Howard, Rebecca L; Coyte, Peter C; Wijeysundera, Harindra C
2018-05-01
Although transcatheter aortic valve implantation has been shown to be noninferior to surgical aortic valve replacement in patients with severe aortic stenosis at intermediate surgical risk, the cost-effectiveness of this strategy in this population is unknown. Our objective was to conduct a cost-utility analysis comparing transcatheter aortic valve implantation with surgical aortic valve replacement in the population with intermediate risk severe aortic stenosis. A fully probabilistic Markov model with 30-day cycles was constructed from the Canadian third-party payer's perspective to estimate the difference in cost and effectiveness (measured as quality-adjusted life years) of transcatheter aortic valve implantation versus surgical aortic valve replacement for intermediate-risk patients over a lifetime time horizon, discounted at 1.5% per annum. Clinical trial data from The Placement of Aortic Transcatheter Valve 2 informed the efficacy inputs. Costs (adjusted to 2016 Canadian dollars) were obtained from the Canadian Institute of Health Information and the Ontario Schedule of Benefits. Incremental cost-effectiveness ratios were calculated. In the base-case analysis, total lifetime costs for transcatheter aortic valve implantation were $10,548 higher than surgical aortic valve replacement but added 0.23 quality-adjusted life years, for an incremental cost-effectiveness ratio of $46,083/quality-adjusted life-years gained. Deterministic 1-way analyses showed that the incremental cost-effectiveness ratio was sensitive to rates of complications and cost of the transcatheter aortic valve implantation prosthesis. There was moderate-to-high parameter uncertainty; transcatheter aortic valve implantation was the preferred option in only 52.7% and 55.4% of the simulations at a $50,000 and $100,000 per quality-adjusted life years willingness-to-pay thresholds, respectively. On the basis of current evidence, transcatheter aortic valve implantation may be cost-effective for the treatment of severe aortic stenosis in patients with intermediate surgical risk. There remains moderate-to-high uncertainty surrounding the base-case incremental cost-effectiveness ratio. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Sankaran, K. J.; Srinivasu, K.; Yeh, C. J.; Thomas, J. P.; Drijkoningen, S.; Pobedinskas, P.; Sundaravel, B.; Leou, K. C.; Leung, K. T.; Van Bael, M. K.; Schreck, M.; Lin, I. N.; Haenen, K.
2017-06-01
The field electron emission (FEE) properties of nitrogen-incorporated nanocrystalline diamond films were enhanced due to Li-ion implantation/annealing processes. Li-ion implantation mainly induced the formation of electron trap centers inside diamond grains, whereas post-annealing healed the defects and converted the a-C phase into nanographite, forming conduction channels for effective transport of electrons. This resulted in a high electrical conductivity of 11.0 S/cm and enhanced FEE performance with a low turn-on field of 10.6 V/μm, a high current density of 25.5 mA/cm2 (at 23.2 V/μm), and a high lifetime stability of 1,090 min for nitrogen incorporated nanocrystalline diamond films.
Implantable batteryless device for on-demand and pulsatile insulin administration
NASA Astrophysics Data System (ADS)
Lee, Seung Ho; Lee, Young Bin; Kim, Byung Hwi; Lee, Cheol; Cho, Young Min; Kim, Se-Na; Park, Chun Gwon; Cho, Yong-Chan; Choy, Young Bin
2017-04-01
Many implantable systems have been designed for long-term, pulsatile delivery of insulin, but the lifetime of these devices is limited by the need for battery replacement and consequent replacement surgery. Here we propose a batteryless, fully implantable insulin pump that can be actuated by a magnetic field. The pump is prepared by simple-assembly of magnets and constituent units and comprises a drug reservoir and actuator equipped with a plunger and barrel, each assembled with a magnet. The plunger moves to noninvasively infuse insulin only when a magnetic field is applied on the exterior surface of the body. Here we show that the dose is easily controlled by varying the number of magnet applications. Also, pump implantation in diabetic rats results in profiles of insulin concentration and decreased blood glucose levels similar to those observed in rats treated with conventional subcutaneous insulin injections.
[Cost Analysis of Cochlear Implantation in Adults].
Raths, S; Lenarz, T; Lesinski-Schiedat, A; Flessa, S
2016-04-01
The number of implantation of cochlear implants has steadily risen in recent years. Reasons for this are an extension of indication criteria, demographic change, increased quality of life needs and greater acceptance. The consequences are rising expenditure for statutory health insurance (SHI) for cochlear implantation. A detailed calculation of lifetime costs from SHI's perspective for postlingually deafened adolescents and adults is essential in estimating future cost developments. Calculations are based on accounting data from the Hannover Medical School. With regard to further life expectancy, average costs of preoperative diagnosis, surgery, rehabilitation, follow-ups, processor upgrades and electrical maintenance were discounted to their present value at age of implantation. There is an inverse relation between cost of unilateral cochlear implantation and age of initial implantation. From SHI's perspective, the intervention costs between 36,001 and 68,970 € ($ 42,504-$ 81,429). The largest cost components are initial implantation and processor upgrades. Compared to the UK the cost of cochlear implantation in Germany seems to be significantly lower. In particular the costs of, rehabilitation and maintenance in Germany cause only a small percentage of total costs. Also, the costs during the first year of treatment seem comparatively low. With regard to future spending of SHI due to implant innovations and associated extension of indication, increasing cost may be suspected. © Georg Thieme Verlag KG Stuttgart · New York.
Optima HD Imax: Molecular Implant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tieger, D. R.; Splinter, P. R.; Hsieh, T. J.
2008-11-03
Molecular implantation offers semiconductor device manufacturers multiple advantages over traditional high current ion implanters. The dose multiplication due to implanting more than one atom per molecule and the transport of beams at higher energies relative to the effective particle energies result in significant throughput enhancements without risk of energy contamination. The Optima HD Imax is introduced with molecular implant capability and the ability to reach up to 4.2 keV effective {sup 11}B from octadecaborane (B{sub 18}H{sub 22}). The ion source and beamline are optimized for molecular species ionization and transport. The beamline is coupled to the Optima HD mechanically scannedmore » endstation. The use of spot beam technology with ionized molecules maximizes the throughput potential and produces uniform implants with fast setup time and with superior angle control. The implanter architecture is designed to run multiple molecular species; for example, in addition to B{sub 18}H{sub 22} the system is capable of implanting carbon molecules for strain engineering and shallow junction engineering. Source lifetime data and typical operating conditions are described both for high dose, memory applications such as dual poly gate as well as lower energy implants for source drain extension and contact implants. Throughputs have been achieved in excess of 50 wafers per hour at doses up to 1x10{sup 16} ions/cm{sup 2} and for energies as low as 1 keV.« less
NASA Astrophysics Data System (ADS)
Uedono, A.; Wei, L.; Tanigawa, S.; Suzuki, R.; Ohgaki, H.; Mikado, T.; Ohji, Y.
1993-12-01
The positron annihilation in a metal-oxide semiconductor was studied by using a pulsed monoenergetic positron beam. Lifetime spectra of positrons were measured as a function of incident positron energy for a polycrystalline Si(100 nm)/SiO2(400 nm)/Si specimen. Applying a gate voltage between the polycrystalline Si film and the Si substrate, positrons implanted into the specimen were accumulated at the SiO2/Si interface. From the measurements, it was found that the annihilation probability of ortho-positronium (ortho-Ps) drastically decreased at the SiO2/Si interface. The observed inhibition of the Ps formation was attributed to an interaction between positrons and defects at the SiO2/Si interface.
Inorganic-organic thin implant coatings deposited by lasers.
Sima, Felix; Davidson, Patricia M; Dentzer, Joseph; Gadiou, Roger; Pauthe, Emmanuel; Gallet, Olivier; Mihailescu, Ion N; Anselme, Karine
2015-01-14
The lifetime of bone implants inside the human body is directly related to their osseointegration. Ideally, future materials should be inspired by human tissues and provide the material structure-function relationship from which synthetic advanced biomimetic materials capable of replacing, repairing, or regenerating human tissues can be produced. This work describes the development of biomimetic thin coatings on titanium implants to improve implant osseointegration. The assembly of an inorganic-organic biomimetic structure by UV laser pulses is reported. The structure consists of a hydroxyapatite (HA) film grown onto a titanium substrate by pulsed-laser deposition (PLD) and activated by a top fibronectin (FN) coating deposited by matrix-assisted pulsed laser evaporation (MAPLE). A pulsed KrF* laser source (λ = 248 nm, τ = 25 ns) was employed at fluences of 7 and 0.7J/cm(2) for HA and FN transfer, respectively. Films approximately 1500 and 450 nm thick were obtained for HA and FN, respectively. A new cryogenic temperature-programmed desorption mass spectrometry analysis method was employed to accurately measure the quantity of immobilized protein. We determined that less than 7 μg FN per cm(2) HA surface is adequate to improve adhesion, spreading, and differentiation of osteoprogenitor cells. We believe that the proposed fabrication method opens the door to combining and immobilizing two or more inorganic and organic materials on a solid substrate in a well-defined manner. The flexibility of this method enables the synthesis of new hybrid materials by simply tailoring the irradiation conditions according to the thermo-physical properties of the starting materials.
Marques, Isabella da Silva Vieira; Alfaro, Maria Fernanda; Saito, Miki Taketomi; da Cruz, Nilson Cristino; Takoudis, Christos; Landers, Richard; Mesquita, Marcelo Ferraz; Nociti Junior, Francisco Humberto; Mathew, Mathew T.; Sukotjo, Cortino; Barão, Valentim Adelino Ricardo
2016-01-01
Biofunctionalized surfaces for implants are currently receiving much attention in the health care sector. Our aims were (1) to create bioactive Ti-coatings doped with Ca, P, Si, and Ag produced by microarc oxidation (MAO) to improve the surface properties of biomedical implants, (2) to investigate the TiO2 layer stability under wear and corrosion, and (3) to evaluate human mesenchymal stem cells (hMSCs) responses cultured on the modified surfaces. Tribocorrosion and cell experiments were performed following the MAO treatment. Samples were divided as a function of different Ca/P concentrations and treatment duration. Higher Ca concentration produced larger porous and harder coatings compared to the untreated group (p < 0.001), due to the presence of rutile structure. Free potentials experiments showed lower drops (−0.6 V) and higher coating lifetime during sliding for higher Ca concentration, whereas lower concentrations presented similar drops (−0.8 V) compared to an untreated group wherein the drop occurred immediately after the sliding started. MAO-treated surfaces improved the matrix formation and osteogenic gene expression levels of hMSCs. Higher Ca/P ratios and the addition of Ag nanoparticles into the oxide layer presented better surface properties, tribocorrosive behavior, and cell responses. MAO is a promising technique to enhance the biological, chemical, and mechanical properties of dental implant surfaces. PMID:27514370
Marques, Isabella da Silva Vieira; Alfaro, Maria Fernanda; Saito, Miki Taketomi; da Cruz, Nilson Cristino; Takoudis, Christos; Landers, Richard; Mesquita, Marcelo Ferraz; Nociti Junior, Francisco Humberto; Mathew, Mathew T; Sukotjo, Cortino; Barão, Valentim Adelino Ricardo
2016-09-11
Biofunctionalized surfaces for implants are currently receiving much attention in the health care sector. Our aims were (1) to create bioactive Ti-coatings doped with Ca, P, Si, and Ag produced by microarc oxidation (MAO) to improve the surface properties of biomedical implants, (2) to investigate the TiO2 layer stability under wear and corrosion, and (3) to evaluate human mesenchymal stem cells (hMSCs) responses cultured on the modified surfaces. Tribocorrosion and cell experiments were performed following the MAO treatment. Samples were divided as a function of different Ca/P concentrations and treatment duration. Higher Ca concentration produced larger porous and harder coatings compared to the untreated group (p < 0.001), due to the presence of rutile structure. Free potentials experiments showed lower drops (-0.6 V) and higher coating lifetime during sliding for higher Ca concentration, whereas lower concentrations presented similar drops (-0.8 V) compared to an untreated group wherein the drop occurred immediately after the sliding started. MAO-treated surfaces improved the matrix formation and osteogenic gene expression levels of hMSCs. Higher Ca/P ratios and the addition of Ag nanoparticles into the oxide layer presented better surface properties, tribocorrosive behavior, and cell responses. MAO is a promising technique to enhance the biological, chemical, and mechanical properties of dental implant surfaces.
Silicone Molding and Lifetime Testing of Peripheral Nerve Interfaces for Neuroprostheses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupte, Kimaya; Tolosa, Vanessa
Implantable peripheral nerve cuffs have a large application in neuroprostheses as they can be used to restore sensation to those with upper limb amputations. Modern day prosthetics, while lessening the pain associated with phantom limb syndrome, have limited fine motor control and do not provide sensory feedback to patients. Sensory feedback with prosthetics requires communication between the nervous system and limbs, and is still a challenge to accomplish with amputees. Establishing this communication between the peripheral nerves in the arm and artificial limbs is vital as prosthetics research aims to provide sensory feedback to amputees. Peripheral nerve cuffs restore sensationmore » by electrically stimulating certain parts of the nerve in order to create feeling in the hand. Cuff electrodes have an advantage over standard electrodes as they have high selective stimulation by bringing the electrical interface close to the neural tissue in order to selectively activate targeted regions of a peripheral nerve. In order to further improve the selective stimulation of these nerve cuffs, there is need for finer spatial resolution among electrodes. One method to achieve a higher spatial resolution is to increase the electrode density on the cuff itself. Microfabrication techniques can be used to achieve this higher electrode density. Using L-Edit, a layout editor, microfabricated peripheral nerve cuffs were designed with a higher electrode density than the current model. This increase in electrode density translates to an increase in spatial resolution by at least one order of magnitude. Microfabricated devices also have two separate components that are necessary to understand before implantation: lifetime of the device and assembly to prevent nerve damage. Silicone molding procedures were optimized so that devices do not damage nerves in vivo, and lifetime testing was performed on test microfabricated devices to determine their lifetime in vivo. Future work of this project would include fabricating some of the designed devices and seeing how they compare to the current cuffs in terms of their electrical performance, lifetime, shape, and mechanical properties.« less
Microelectronic bioinstrumentation systems
NASA Technical Reports Server (NTRS)
Ko, W. H.; Hynecek, J.
1975-01-01
The possibility of using RF fields to power biologically implanted transmitters used in biomedical experiments was investigated. This approach would be especially useful when animal subjects are strapped in chairs or confined in cages. A telemetry system using an external source of energy has the additional advantage of not being limited in operation by battery lifetime and can therefore operate for virtually infinite lengths of time. A description of a system based on this principle is given. Progress in the development of battery-driven transmitters is also reported, including an ingestible temperature telemetry system and a resistance-to-pulse frequency convertor for implantable temperature telemetry systems.
NASA Astrophysics Data System (ADS)
Sankaran, K. J.; Manoharan, D.; Sundaravel, B.; Lin, I. N.
2016-09-01
Multienergy Au-ion implantation enhanced the electrical conductivity of heterogranular structured diamond films grown on Au-coated Si substrates to a high level of 5076.0 (Ω cm)-1 and improved the field electron emission (FEE) characteristics of the films to low turn-on field of 1.6 V/μm, high current density of 5.4 mA/cm2 (@ 2.65 V/μm), and high lifetime stability of 1825 min. The catalytic induction of nanographitic phases in the films due to Au-ion implantation and the formation of diamond-to-Si eutectic interface layer due to Au-coating on Si together encouraged the efficient conducting channels for electron transport, thereby improved the FEE characteristics of the films.
Roxby, Daniel N; Nham Tran; Pak-Lam Yu; Nguyen, Hung T
2016-08-01
Implanted biomedical devices typically last a number of years before their batteries are depleted and a surgery is required to replace them. A Microbial Fuel Cell (MFC) is a device which by using bacteria, directly breaks down sugars to generate electricity. Conceptually there is potential to continually power implanted medical devices for the lifetime of a patient. To investigate the practical potential of this technology, H-Cell Dual Chamber MFCs were evaluated with two different growth solutions and measurements recorded for maximum power output both of individual MFCs and connected MFCs. Using Luria-Bertani media and connecting MFCs in a hybrid series and parallel arrangement with larger membrane sizes showed the highest power output and the greatest potential for replacing implanted batteries.
Laurendeau, C; Lafuma, A; Berdeaux, G
2009-09-01
To compare the lifetime costs of freeing astigmatic patients from spectacles after bilateral cataract surgery implanting toric intraocular lenses (IOLs: i.e., Acrysof Toric) versus monofocal IOLs, in France, Italy, Germany and Spain. A Markov model followed patient cohorts from cataract surgery until death. Prevalence rates of patients not needing spectacles and the types of spectacles prescribed for those requiring them were obtained from clinical trials and national surveys. The economic perspective was societal. Mortality rates were incorporated into the model. Discount rates were applied. A sensitivity analysis was performed on non-discounted costs. Fewer patients with toric IOLs needed spectacles for distance vision than patients with monofocal IOLs. With monofocal IOLs more than 66% of patients needed complex spectacles compared to less than 25% implanted with toric IOLs. In France and Italy, toric IOLs reduced overall costs relative to otherwise high spectacle costs after cataract surgery. Savings were 897.0 euros (France), 822.5 euros (Germany), 895.8 euros (Italy) and 391.6 euros (Spain), without discounting. On applying a 3% discount rate the costs became 691.7 euros, 646.4 euros, 693.9 euros and 308.2 euros, respectively. Bilateral toric IOL implants in astigmatic patients decreased spectacle dependence for distance vision and the need for complex spectacles. The economic consequences for patients depended on the national spectacle costs usually incurred after cataract surgery.
Song, Kwangsun; Han, Jung Hyun; Yang, Hyung Chae; Nam, Kwang Il; Lee, Jongho
2017-06-15
Medical electronic implants can significantly improve people's health and quality of life. These implants are typically powered by batteries, which usually have a finite lifetime and therefore must be replaced periodically using surgical procedures. Recently, subdermal solar cells that can generate electricity by absorbing light transmitted through skin have been proposed as a sustainable electricity source to power medical electronic implants in bodies. However, the results to date have been obtained with animal models. To apply the technology to human beings, electrical performance should be characterized using human skin covering the subdermal solar cells. In this paper, we present electrical performance results (up to 9.05mW/cm 2 ) of the implantable solar cell array under 59 human skin samples isolated from 10 cadavers. The results indicate that the power densities depend on the thickness and tone of the human skin, e.g., higher power was generated under thinner and brighter skin. The generated power density is high enough to operate currently available medical electronic implants such as pacemakers that require tens of microwatt. Copyright © 2016 Elsevier B.V. All rights reserved.
In vivo Characterization of Amorphous Silicon Carbide As a Biomaterial for Chronic Neural Interfaces
Knaack, Gretchen L.; McHail, Daniel G.; Borda, German; Koo, Beomseo; Peixoto, Nathalia; Cogan, Stuart F.; Dumas, Theodore C.; Pancrazio, Joseph J.
2016-01-01
Implantable microelectrode arrays (MEAs) offer clinical promise for prosthetic devices by enabling restoration of communication and control of artificial limbs. While proof-of-concept recordings from MEAs have been promising, work in animal models demonstrates that the obtained signals degrade over time. Both material robustness and tissue response are acknowledged to have a role in device lifetime. Amorphous Silicon carbide (a-SiC), a robust material that is corrosion resistant, has emerged as an alternative encapsulation layer for implantable devices. We systematically examined the impact of a-SiC coating on Si probes by immunohistochemical characterization of key markers implicated in tissue-device response. After implantation, we performed device capture immunohistochemical labeling of neurons, astrocytes, and activated microglia/macrophages after 4 and 8 weeks of implantation. Neuron loss and microglia activation were similar between Si and a-SiC coated probes, while tissue implanted with a-SiC displayed a reduction in astrocytes adjacent to the probe. These results suggest that a-SiC has a similar biocompatibility profile as Si, and may be suitable for implantable MEA applications as a hermetic coating to prevent material degradation. PMID:27445672
Knaack, Gretchen L; McHail, Daniel G; Borda, German; Koo, Beomseo; Peixoto, Nathalia; Cogan, Stuart F; Dumas, Theodore C; Pancrazio, Joseph J
2016-01-01
Implantable microelectrode arrays (MEAs) offer clinical promise for prosthetic devices by enabling restoration of communication and control of artificial limbs. While proof-of-concept recordings from MEAs have been promising, work in animal models demonstrates that the obtained signals degrade over time. Both material robustness and tissue response are acknowledged to have a role in device lifetime. Amorphous Silicon carbide (a-SiC), a robust material that is corrosion resistant, has emerged as an alternative encapsulation layer for implantable devices. We systematically examined the impact of a-SiC coating on Si probes by immunohistochemical characterization of key markers implicated in tissue-device response. After implantation, we performed device capture immunohistochemical labeling of neurons, astrocytes, and activated microglia/macrophages after 4 and 8 weeks of implantation. Neuron loss and microglia activation were similar between Si and a-SiC coated probes, while tissue implanted with a-SiC displayed a reduction in astrocytes adjacent to the probe. These results suggest that a-SiC has a similar biocompatibility profile as Si, and may be suitable for implantable MEA applications as a hermetic coating to prevent material degradation.
Energy harvesting for human wearable and implantable bio-sensors.
Mitcheson, Paul D
2010-01-01
There are clear trade-offs between functionality, battery lifetime and battery volume for wearable and implantable wireless-biosensors which energy harvesting devices may be able to overcome. Reliable energy harvesting has now become a reality for machine condition monitoring and is finding applications in chemical process plants, refineries and water treatment works. However, practical miniature devices that can harvest sufficient energy from the human body to power a wireless bio-sensor are still in their infancy. This paper reviews the options for human energy harvesting in order to determine power availability for harvester-powered body sensor networks. The main competing technologies for energy harvesting from the human body are inertial kinetic energy harvesting devices and thermoelectric devices. These devices are advantageous to some other types as they can be hermetically sealed. In this paper the fundamental limit to the power output of these devices is compared as a function of generator volume when attached to a human whilst walking and running. It is shown that the kinetic energy devices have the highest fundamental power limits in both cases. However, when a comparison is made between the devices using device effectivenesses figures from previously demonstrated prototypes presented in the literature, the thermal device is competitive with the kinetic energy harvesting device when the subject is running and achieves the highest power density when the subject is walking.
Concentration of point defects in 4H-SiC characterized by a magnetic measurement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, B.; Jia, R. X., E-mail: rxjia@mail.xidian.edu.cn; Wang, Y. T.
A magnetic method is presented to characterize the concentration of point defects in silicon carbide. In this method, the concentration of common charged point defects, which is related to the density of paramagnetic centers, is determined by fitting the paramagnetic component of the specimen to the Brillouin function. Several parameters in the Brillouin function can be measured such as: the g-factor can be obtained from electron spin resonance spectroscopy, and the magnetic moment of paramagnetic centers can be obtained from positron lifetime spectroscopy combined with a first-principles calculation. To evaluate the characterization method, silicon carbide specimens with different concentrations ofmore » point defects are prepared with aluminum ion implantation. The fitting results of the densities of paramagnetic centers for the implanted doses of 1 × 10{sup 14} cm{sup −2}, 1 × 10{sup 15} cm{sup −2} and 1 × 10{sup 16} cm{sup −2} are 6.52 × 10{sup 14}/g, 1.14 × 10{sup 15}/g and 9.45 × 10{sup 14}/g, respectively. The same trends are also observed for the S-parameters in the Doppler broadening spectra. It is shown that this method is an accurate and convenient way to obtain the concentration of point defects in 4H-SiC.« less
Hanada, Takashi; Yorozu, Atsunori; Shinya, Yukiko; Kuroiwa, Nobuko; Ohashi, Toshio; Saito, Shiro; Shigematsu, Naoyuki
2016-01-01
To broaden the current understanding of radiation exposure and risk and to provide concrete evidence of radiation safety related to (125)I seed implantation. Direct radiation exposure measurements were obtained from dosimeters provided to 25 patients who underwent (125)I seed implantation, along with their family members. The estimated lifetime exposure dose and the precaution time for holding children near the patient's chest were calculated in two study periods. During the first and second study period, the mean estimated lifetime exposure doses were, respectively, 7.61 (range: 0.45, 20.21) mSv and 6.84 (range: 0.41, 19.20) mSv for patients, and 0.19 (range: 0.02, 0.54) mSv and 0.25 (range: 0.04, 1.00) mSv for family members. The mean ratios of first and second period measurements were 1.05 (range: 0.44, 3.18) for patients and 1.82 (range: 0.21, 7.04) for family members. The corresponding absolute differences between first and second period measurements were -0.77 (range: -11.40, 7.63) mSv and 0.06 (range: -0.26, 0.79) mSv, respectively. Assuming a dose limit of 1 mSv, the precaution times for holding a child every day of the first and second periods were 250.9 (range: 71.3, 849.4) min and 275.2 (range: 75.0, 883.4) min, respectively. Assuming a dose limit of 0.5 mSv, the corresponding precaution times were 179.0 (range: 35.6, 811.5) min and 178.9 (range: 37.5, 1131.8) min, respectively. Our study demonstrated low radiation exposures to family members of patients undergoing (125)I prostate implantation. It was clear that (125)I seed implantation did not pose a threat to the safety of family members. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
El-Anwar, Mohamed I.; El-Taftazany, Eman A.; Hamed, Hamdy A.; ElHay, Mohamed A. Abd
2017-01-01
AIM: This study aimed to compare the stresses generated by using two or four root form dental implants supporting mandibular overdentures that were retained with ball and locator attachments. METHODS: Under ANSYS environment, four 3D finite element models were prepared. These models simulated complete overdentures supported by two or four implants with either ball or locator attachments as a connection mechanism. The models’ components were created by CAD/CAM package then were imported to ANSYS. Load of 100 N was applied at the right premolar/molar region vertically and at an oblique angle of 110° from lingual direction. RESULTS: Within the conditions of this research, in all cases, it was found that cortical and cancellous bone regions were the least to be stressed. Also, the ball attachment produced higher stresses. CONCLUSION: Caps deformation and stresses are negligible in cases of using locator attachment in comparison to ball attachments. This may indicate longer lifetime and less repair/maintenance operations in implant overdentures retained by locator attachments. Although the study revealed that bone was insensitive to a number of implants or attachment type, it may be recommended to use two implants in the canine region than using four, where the locator attachments were found to be better. PMID:28507636
El-Anwar, Mohamed I; El-Taftazany, Eman A; Hamed, Hamdy A; ElHay, Mohamed A Abd
2017-04-15
This study aimed to compare the stresses generated by using two or four root form dental implants supporting mandibular overdentures that were retained with ball and locator attachments. Under ANSYS environment, four 3D finite element models were prepared. These models simulated complete overdentures supported by two or four implants with either ball or locator attachments as a connection mechanism. The models' components were created by CAD/CAM package then were imported to ANSYS. Load of 100 N was applied at the right premolar/molar region vertically and at an oblique angle of 110° from lingual direction. Within the conditions of this research, in all cases, it was found that cortical and cancellous bone regions were the least to be stressed. Also, the ball attachment produced higher stresses. Caps deformation and stresses are negligible in cases of using locator attachment in comparison to ball attachments. This may indicate longer lifetime and less repair/maintenance operations in implant overdentures retained by locator attachments. Although the study revealed that bone was insensitive to a number of implants or attachment type, it may be recommended to use two implants in the canine region than using four, where the locator attachments were found to be better.
Saunders, James E; Barrs, David M; Gong, Wenfeng; Wilson, Blake S; Mojica, Karen; Tucci, Debara L
2015-09-01
Cochlear implantation (CI) is a common intervention for severe-to-profound hearing loss in high-income countries, but is not commonly available to children in low resource environments. Owing in part to the device costs, CI has been assumed to be less economical than deaf education for low resource countries. The purpose of this study is to compare the cost effectiveness of the two interventions for children with severe-to-profound sensorineural hearing loss (SNHL) in a model using disability adjusted life years (DALYs). Cost estimates were derived from published data, expert opinion, and known costs of services in Nicaragua. Individual costs and lifetime DALY estimates with a 3% discounting rate were applied to both two interventions. Sensitivity analysis was implemented to evaluate the effect on the discounted cost of five key components: implant cost, audiology salary, speech therapy salary, number of children implanted per year, and device failure probability. The costs per DALY averted are $5,898 and $5,529 for CI and deaf education, respectively. Using standards set by the WHO, both interventions are cost effective. Sensitivity analysis shows that when all costs set to maximum estimates, CI is still cost effective. Using a conservative DALY analysis, both CI and deaf education are cost-effective treatment alternatives for severe-to-profound SNHL. CI intervention costs are not only influenced by the initial surgery and device costs but also by rehabilitation costs and the lifetime maintenance, device replacement, and battery costs. The major CI cost differences in this low resource setting were increased initial training and infrastructure costs, but lower medical personnel and surgery costs.
NASA Astrophysics Data System (ADS)
Melican, Mora Carolynne
Various surface treatments and coating materials have been tested for use on metal alloy orthopaedic implants. Their purpose has been to enhance the bioactivity of the implant surfaces, and thus to increase the rate and degree of bony attachment in vivo in an attempt to hasten recovery time, increase implant service lifetime, and lessen pain associated with loosened orthopaedic implants. A series of in vivo and in vitro studies were performed to determine the influence of different implant surfaces including porous metal surfaces with varied porosity with depth, resorbable and non-resorbable plasma-sprayed hydroxyapatite (HA) coatings, and finally HA coatings with an adsorbed layer of human recombinant bone morphogenetic protein (rhBMP-2), an osteoinductive protein. Textured as-cast metal surfaces produced by investment casting in three dimensionally printed ceramic molds have exhibited superior bony ingrowth and attachment. Plasma-sprayed HA coatings have been shown to be appropriate substrates for osteoblast proliferation (particularly on highly crystalline HA) and stem cell proliferation (particularly on less crystalline HA). Less crystalline HA coatings have shown promise as delivery systems for different levels of rhBMP-2. The osteoinductive protein has been shown to remain active after delivery to the system, and was most effective when delivered in concentrations ranging from 30 to 50 ng/ml. Combinations of these surface treatments for metal implant surfaces warrant further investigation.
Security and privacy issues in implantable medical devices: A comprehensive survey.
Camara, Carmen; Peris-Lopez, Pedro; Tapiador, Juan E
2015-06-01
Bioengineering is a field in expansion. New technologies are appearing to provide a more efficient treatment of diseases or human deficiencies. Implantable Medical Devices (IMDs) constitute one example, these being devices with more computing, decision making and communication capabilities. Several research works in the computer security field have identified serious security and privacy risks in IMDs that could compromise the implant and even the health of the patient who carries it. This article surveys the main security goals for the next generation of IMDs and analyzes the most relevant protection mechanisms proposed so far. On the one hand, the security proposals must have into consideration the inherent constraints of these small and implanted devices: energy, storage and computing power. On the other hand, proposed solutions must achieve an adequate balance between the safety of the patient and the security level offered, with the battery lifetime being another critical parameter in the design phase. Copyright © 2015 Elsevier Inc. All rights reserved.
Mulcahy, Daniel M.; Garner, Gerald W.
1999-01-01
Male polar bears (Ursus maritimus) have not been successfully instrumented with satellite transmitters because they readily shed collar-mounted transmitters. Seven male polar bears were captured on the pack ice off the northern coast of Alaska and surgically implanted with satellite transmitters with percutaneous antennae into the subcutaneous space of the dorsal cervical region. Transmitters failed prematurely with lifetimes of 30-161 days (x̄ = 97 days). Efforts to relocate implanted bears after transmitters failed were not successful. The mean number of location solutions per transmitter was 204 (range 118-369). An average of 10% and 19% of the locations were accurate to <150 m and to 150-350 m, respectively. Our successful tracking of male polar bears, the high quality of locations obtained from transmitters with percutaneous antennae implanted in the subcutaneous space, and the low visibility of such units make further technical development worthwhile if the reason for premature failure of the transmitters can be determined.
Tribocorrosion behaviour of anodic treated titanium surfaces intended for dental implants
NASA Astrophysics Data System (ADS)
Alves, A. C.; Oliveira, F.; Wenger, F.; Ponthiaux, P.; Celis, J.-P.; Rocha, L. A.
2013-10-01
Tribocorrosion plays an important role in the lifetime of metallic implants. Once implanted, biomaterials are subjected to micro-movements in aggressive biological fluids. Titanium is widely used as an implant material because it spontaneously forms a compact and protective nanometric thick oxide layer, mainly TiO2, in ambient air. That layer provides good corrosion resistance, and very low toxicity, but its low wear resistance is a concern. In this work, an anodizing treatment was performed on commercial pure titanium to form a homogeneous thick oxide surface layer in order to provide bioactivity and improve the biological, chemical and mechanical properties. Anodizing was performed in an electrolyte containing β-glycerophosphate and calcium acetate. The influence of the calcium acetate content on the tribocorrosion behaviour of the anodized material was studied. The concentration of calcium acetate in the electrolyte was found to largely affect the crystallographic structure of the resulting oxide layer. Better tribocorrosion behaviour was noticed on increasing the calcium acetate concentration.
NASA Astrophysics Data System (ADS)
Xu, Huijing; Weltman Hirschberg, Ahuva; Scholten, Kee; Berger, Theodore William; Song, Dong; Meng, Ellis
2018-02-01
Objective. The success of a cortical prosthetic device relies upon its ability to attain resolvable spikes from many neurons in particular neural networks over long periods of time. Traditionally, lifetimes of neural recordings are greatly limited by the body’s immune response against the foreign implant which causes neuronal death and glial scarring. This immune reaction is posited to be exacerbated by micromotion between the implant, which is often rigid, and the surrounding, soft brain tissue, and attenuates the quality of recordings over time. Approach. In an attempt to minimize the foreign body response to a penetrating neural array that records from multiple brain regions, Parylene C, a flexible, biocompatible polymer was used as the substrate material for a functional, proof-of-concept neural array with a reduced elastic modulus. This probe array was designed and fabricated to have 64 electrodes positioned to match the anatomy of the rat hippocampus and allow for simultaneous recordings between two cell-body layers of interest. A dissolvable brace was used for deep-brain penetration of the flexible array. Main results. Arrays were electrochemically characterized at the benchtop, and a novel insertion technique that restricts acute insertion injury enabled accurate target placement of four, bare, flexible arrays to greater than 4 mm deep into the rat brain. Arrays were tested acutely and in vivo recordings taken intra-operatively reveal spikes in both targeted regions of the hippocampus with spike amplitudes and noise levels similar to those recorded with microwires. Histological staining of a sham array implanted for one month reveals limited astrocytic scarring and neuronal death around the implant. Significance. This work represents one of the first examples of a penetrating polymer probe array that records from individual neurons in structures that lie deep within the brain.
Mechanical stability of Ti6Al4V implant material after femtosecond laser irradiation
NASA Astrophysics Data System (ADS)
Symietz, Christian; Lehmann, Erhard; Gildenhaar, Renate; Hackbarth, Andreas; Berger, Georg; Krüger, Jörg
2012-07-01
The surface of a titanium alloy (Ti6Al4V) implant material was covered with a bioactive calcium alkali phosphate ceramic with the aim to accelerate the healing and to form a stronger bond to living bone tissue. To fix the ceramic powder we used a femtosecond laser, which causes a thin surface melting of the metal. It is a requirement to prove that the laser irradiation would not reduce the lifetime of implants. Here we present the results of mechanical stability tests, determined by the rotating bending fatigue strength of sample rods. After describing the sample surfaces and their modifications caused by the laser treatment we give evidence for an unchanged mechanical stability. This applies not only to the ceramic fixation but also to a comparatively strong laser ablation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moutanabbir, O.; Scholz, R.; Goesele, U.
We present a detailed study of the thermal evolution of H ion-induced vacancy related complexes and voids in bulk GaN implanted under ion-cut conditions. By using transmission electron microscopy, we found that the damage band in as-implanted GaN is decorated with a high density of nanobubbles of approx1-2 nm in diameter. Variable energy Doppler broadening spectroscopy showed that this band contains vacancy clusters and voids. In addition to vacancy clusters, the presence of V{sub Ga}, V{sub Ga}-H{sub 2}, and V{sub Ga}V{sub N} complexes was evidenced by pulsed low-energy positron lifetime spectroscopy. Subtle changes upon annealing in these vacancy complexes weremore » also investigated. As a general trend, a growth in open-volume defects is detected in parallel to an increase in both size and density of nanobubbles. The observed vacancy complexes appear to be stable during annealing. However, for temperatures above 450 deg. C, unusually large lifetimes were measured. These lifetimes are attributed to the formation of positronium in GaN. Since the formation of positronium is not possible in a dense semiconductor, our finding demonstrates the presence of sufficiently large open-volume defects in this temperature range. Based on the Tao-Eldrup model, the average lattice opening during thermal annealing was quantified. We found that a void diameter of 0.4 nm is induced by annealing at 600 deg. C. The role of these complexes in the subsurface microcracking is discussed.« less
Scanning electron microscope fractography of induced fatigue-damaged saline breast implants.
Brandon, H J; Jerina, K L; Savoy, T L; Wolf, C J
2006-01-01
Breast implant strength and durability is presently an important topic in biomaterials science. Research studies are being conducted to determine the mechanisms and rates of failure in order to assess the in vivo performance of breast implants. Fatigue life is a measure of breast implant durability since fatigue failure is a potential in vivo failure mechanism. This study describes the characterization of the fracture surface morphology of breast implant shell regions that have failed due to cyclic fatigue. Saline breast implants were fatigue tested to failure using a laboratory apparatus in which flat plates cyclically compressed the implants. The implants were unimplanted control devices of both textured and smooth saline implants. The failure surfaces of the fatigued shells were examined using scanning electron microscopy (SEM). The morphological features of the failure surfaces are described for implants with short and long fatigue lifetimes. The details of both the inside and outside surfaces of the shell at the failure location are described. Two different modes of failure were observed in both the textured and smooth shells. These modes depend on the magnitude of the cyclic load and corresponding number of fatigue cycles at failure. The first mode is a tear in the shell of about 18 mm in length, and the second mode is a pinhole approximately 1 mm in diameter. Details of the surface morphology for these two types of failure modes and shell thickness data are presented herein. There was no significant change in the crosslink density of the shell as a result of fatigue.
Lukina, Maria; Orlova, Anna; Shirmanova, Marina; Shirokov, Daniil; Pavlikov, Anton; Neubauer, Antje; Studier, Hauke; Becker, Wolfgang; Zagaynova, Elena; Yoshihara, Toshitada; Tobita, Seiji; Shcheslavskiy, Vladislav
2017-02-15
The study of metabolic and oxygen states of cells in a tumor in vivo is crucial for understanding of the mechanisms responsible for tumor development and provides background for the relevant tumor's treatment. Here, we show that a specially designed implantable fiber-optic probe provides a promising tool for optical interrogation of metabolic and oxygen states of a tumor in vivo. In our experiments, the excitation light from a ps diode laser source is delivered to the sample through an exchangeable tip via a multimode fiber, and the emission light is transferred to the detector by another multimode fiber. Fluorescence lifetime of a nicotinamid adenine dinucleotide (NAD(P)H) and phosphorescence lifetime of an oxygen sensor based on an iridium (III) complex of enzothienylpyridine (BTPDM1) are explored both in model experiment in solutions and in living mice.
Fardal, Øystein; Grytten, Jostein; Martin, John; Ellingsen, Stig; Fardal, Patrick; Heasman, Peter; Linden, Gerard J
2018-05-16
Little is known about the financial costs that smoking adds to the life-time treatment of periodontal disease. The total life-time cost of periodontal treatment was modelled using data from private periodontal practice. The costs of initial and supportive therapy, re-treatment and tooth replacements (with bridgework or implants) were identified using average dental charges from the American Dental Association survey. Smoking costs at $6 and $10 for 20 cigarettes were compared to the costs of life-time periodontal treatment for stable and unstable compliant patients. Smoking added 8.8% to the financial cost of the life-time cost of periodontal therapy in stable maintenance patients, 40.1% in patients who needed one extra maintenance visit and 71.4% in patients who needed two extra maintenance visits per year in addition to added re-treatment. The cost of smoking far exceeded the cost of periodontal treatment; For patients who smoked 10 to 40 cigarettes per day at the cost of $6 or $10 a pack, the cost of smoking exceeded the cost of life-time periodontal treatment by between 2.7 and 17.9 times. Smoking 40 cigarettes at $10 a packet for 3.4 years would pay for the entire life-time cost of periodontal treatment. Smoking adds considerable extra financial costs to the life-time treatment of periodontal diseases. The cost of smoking itself exceeds the cost of periodontal therapy. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.
Protracted treatment with corticosterone reduces breeding success in a long-lived bird.
Nelson, Bethany F; Daunt, Francis; Monaghan, Pat; Wanless, Sarah; Butler, Adam; Heidinger, Britt J; Newell, Mark; Dawson, Alistair
2015-01-01
Determining the physiological mechanisms underpinning life-history decisions is essential for understanding the constraints under which life-history strategies can evolve. In long-lived species, where the residual reproductive value of breeders is high, adult survival is a key contributor to lifetime reproductive success. We therefore expect that when adult survival is compromised during reproduction, mechanisms will evolve to redirect resources away from reproduction, with implications for reproductive hormones, adult body mass, nest attendance behaviour and breeding success. We investigated whether manipulating corticosterone, to simulate exposure to an environmental stressor, affected the secretion of prolactin and breeding success in the black-legged kittiwake Rissa tridactyla. We used implanted Alzet® osmotic pumps to administer corticosterone to incubating kittiwakes at a constant rate over a period of approximately 8days. Manipulated birds were compared with sham implanted birds and control birds, which had no implants. There was no significant difference in the body mass of captured individuals at the time of implantation and implant removal. Corticosterone-implanted males showed lower nest attendance during the chick rearing period compared to sham-implanted males; the opposite pattern was found in females. Corticosterone treated birds showed a marginally significant reduction in breeding success compared to sham-implanted individuals, with all failures occurring at least 1week after implant removal. However, prolactin concentrations at implant removal were not significantly different from initial values. We were unable to measure the profile of change in corticosterone during the experiment. However, our results suggest a delayed effect of elevated corticosterone on breeding success rather than an immediate suppression of prolactin concentrations causing premature failure. Copyright © 2014 Elsevier Inc. All rights reserved.
Multidisciplinary approach for in-deep assessment of joint prosthesis failure.
Tessarolo, F; Caola, I; Piccoli, F; Dorigotti, P; Demattè, E; Molinari, M; Malavolta, M; Barbareschi, M; Caciagli, P; Nollo, G
2009-01-01
In spite of advancement in biomaterials and biomechanics, in development of new osteo-integrative materials and coatings, and in macro- micro- component design, a non negligible fraction of the implanted prosthesis fails before the expected lifetime. A prospective observational clinical study has been conducted to define and apply a set of experimental techniques to in-deep assess the failure of joint prosthesis. Microbiological, histological and micro-structural techniques were implemented to specifically address phenomena occurring at the tissue-implant interface. Results obtained from 27 cases of prosthetic joint failure are discussed in terms of sensitivity and specificity. A procedural flow-chart is finally proposed for the assessment of joint prosthesis failure.
Prototype to product—developing a commercially viable neural prosthesis
NASA Astrophysics Data System (ADS)
Seligman, Peter
2009-12-01
The Cochlear implant or 'Bionic ear' is a device that enables people who do not get sufficient benefit from a hearing aid to communicate with the hearing world. The Cochlear implant is not an amplifier, but a device that electrically stimulates the auditory nerve in a way that crudely mimics normal hearing, thus providing a hearing percept. Many recipients are able to understand running speech without the help of lipreading. Cochlear implants have reached a stage of maturity where there are now 170 000 recipients implanted worldwide. The commercial development of these devices has occurred over the last 30 years. This development has been multidisciplinary, including audiologists, engineers, both mechanical and electrical, histologists, materials scientists, physiologists, surgeons and speech pathologists. This paper will trace the development of the device we have today, from the engineering perspective. The special challenges of designing an active device that will work in the human body for a lifetime will be outlined. These challenges include biocompatibility, extreme reliability, safety, patient fitting and surgical issues. It is emphasized that the successful development of a neural prosthesis requires the partnership of academia and industry.
Prototype to product-developing a commercially viable neural prosthesis.
Seligman, Peter
2009-12-01
The Cochlear implant or 'Bionic ear' is a device that enables people who do not get sufficient benefit from a hearing aid to communicate with the hearing world. The Cochlear implant is not an amplifier, but a device that electrically stimulates the auditory nerve in a way that crudely mimics normal hearing, thus providing a hearing percept. Many recipients are able to understand running speech without the help of lipreading. Cochlear implants have reached a stage of maturity where there are now 170 000 recipients implanted worldwide. The commercial development of these devices has occurred over the last 30 years. This development has been multidisciplinary, including audiologists, engineers, both mechanical and electrical, histologists, materials scientists, physiologists, surgeons and speech pathologists. This paper will trace the development of the device we have today, from the engineering perspective. The special challenges of designing an active device that will work in the human body for a lifetime will be outlined. These challenges include biocompatibility, extreme reliability, safety, patient fitting and surgical issues. It is emphasized that the successful development of a neural prosthesis requires the partnership of academia and industry.
NASA Astrophysics Data System (ADS)
Krsjak, Vladimir; Degmova, Jarmila; Sojak, Stanislav; Slugen, Vladimir
2018-02-01
Fe-12 wt% Cr model alloy samples were implanted by 250 keV He2+ ions to three different fluencies (3 × 1017, 9 × 1017 and 1.5 × 1018 cm-2) at T < 100 °C. In a depth profile manner, the implantation impact according to defined peak profile was investigated using variable energy slow positrons, with the primary focus on the 2-13 dpa region. The obtained data were compared to published data on Optifer IX steel samples [1] irradiated in the frame of a two-years irradiation program of the Swiss Spallation Neutron Source. Bi-modal defect distribution represented by two defect components in positron lifetime spectrum reveals two distinct helium bubbles growth mechanisms. While at the lower helium production rate of the spallation environment, the bubbles grow primarily by migration and coalescence, at the high production rates of helium in the implanted samples, the results indicate this growth is driven by Ostwald ripening mechanism. A competitive growth process via emission of interstitial atoms (clusters) is discussed in terms of low-temperature He implantations.
NASA Astrophysics Data System (ADS)
Sinsuebphon, Nattawut; Rudkouskaya, Alena; Barroso, Margarida; Intes, Xavier
2016-02-01
Targeted drug delivery is a critical aspect of successful cancer therapy. Assessment of dynamic distribution of the drug provides relative concentration and bioavailability at the target tissue. The most common approach of the assessment is intensity-based imaging, which only provides information about anatomical distribution. Observation of biomolecular interactions can be performed using Förster resonance energy transfer (FRET). Thus, FRET-based imaging can assess functional distribution and provide potential therapeutic outcomes. In this study, we used wide-field lifetime-based FRET imaging for the study of early functional distribution of transferrin delivery in breast cancer tumor models in small animals. Transferrin is a carrier for cancer drug delivery. Its interaction with its receptor is within a few nanometers, which is suitable for FRET. Alexa Fluor® 700 and Alexa Fluor® 750 were conjugated to holo-transferrin which were then administered via tail vein injection to the mice implanted with T47D breast cancer xenografts. Images were continuously acquired for 60 minutes post-injection. The results showed that transferrin was primarily distributed to the liver, the urinary bladder, and the tumor. The cellular uptake of transferrin, which was indicated by the level of FRET, was high in the liver but very low in the urinary bladder. The results also suggested that the fluorescence intensity and FRET signals were independent. The liver showed increasing intensity and increasing FRET during the observation period, while the urinary bladder showed increasing intensity but minimal FRET. Tumors gave varied results corresponding to their FRET progression. These results were relevant to the biomolecular events that occurred in the animals.
Cozma, Romică Sebastian; Dima-Cozma, Lucia Corina; Rădulescu, Luminiţa Mihaela; Hera, Maria Cristina; Mârţu, Cristian; Olariu, Raluca; Cobzeanu, Bogdan Mihail; Bitere, Oana Roxana; Cobzeanu, Mihail Dan
2018-01-01
Patients with hearing loss who underwent cochlear implantation can present symptomatic or asymptomatic vestibular damages earlier or later after the surgery. The vestibular permanent lesions could be acute, produced by surgical trauma or could be progressive due to local morphological changes made by the presence of the portelectrode in the inner ear (fibrosis related, ossification, basilar membrane distortion, endolymphatic hydrops). Besides histopathological findings in inner ear of cochlear implanted patients, the vestibular permanent damages could be found by assessment of clinical vestibular status. This study reports the sensorial vestibular functional findings for adults in cochlear implanted ears related to the electrode insertion type (cochleostomy or round window approach) and comparing to non-implanted deaf ears. A total of 20 adult patients with 32 cochlear implanted ears (12 patients with binaural cochlear implant and eight with monoaural) were selected for postoperatory vestibular examination by cervical and ocular vestibular myogenic potentials and vestibular caloric tests. The same tests were made for a control group of 22 non-implanted deaf ears. Functional testing results were reported related to the electrode insertion approach. For the cochleostomy group, we found different deficits: in 40% for saccular function, 44% for utricular function, and 12% horizontal canal dysfunction. In round window group, the deficit was present in 14.29% for saccular function, 28.57% for utricular function, and 28.58% for horizontal canal. In 46.88% of implanted ears, the vestibular function was completely preserved on all tested sensors. In conclusion, the vestibular functional status after inner ear surgery presents sensorial damages in 53.12% ears compare with the vestibular dysfunction existing in 50% of deaf non-operated ears. Round window insertion allows for better conservation of the vestibular function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sochman, Jan; Peregrin, Jan H.; Rocek, Miloslav
Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z andmore » 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.« less
Characterization of a transmission positron/positronium converter for antihydrogen production
NASA Astrophysics Data System (ADS)
Aghion, S.; Amsler, C.; Ariga, T.; Bonomi, G.; Brusa, R. S.; Caccia, M.; Caravita, R.; Castelli, F.; Cerchiari, G.; Comparat, D.; Consolati, G.; Demetrio, A.; Di Noto, L.; Doser, M.; Ereditato, A.; Evans, C.; Ferragut, R.; Fesel, J.; Fontana, A.; Gerber, S.; Giammarchi, M.; Gligorova, A.; Guatieri, F.; Haider, S.; Hinterberger, A.; Holmestad, H.; Kellerbauer, A.; Krasnický, D.; Lagomarsino, V.; Lansonneur, P.; Lebrun, P.; Malbrunot, C.; Mariazzi, S.; Matveev, V.; Mazzotta, Z.; Müller, S. R.; Nebbia, G.; Nedelec, P.; Oberthaler, M.; Pacifico, N.; Pagano, D.; Penasa, L.; Petracek, V.; Povolo, L.; Prelz, F.; Prevedelli, M.; Ravelli, L.; Resch, L.; Rienäcker, B.; Robert, J.; Røhne, O. M.; Rotondi, A.; Sacerdoti, M.; Sandaker, H.; Santoro, R.; Scampoli, P.; Simon, M.; Smestad, L.; Sorrentino, F.; Testera, G.; Tietje, I. C.; Widmann, E.; Yzombard, P.; Zimmer, C.; Zmeskal, J.; Zurlo, N.; Andersen, S. L.; Chevallier, J.; Uggerhøj, U. I.; Lyckegaard, F.
2017-09-01
In this work a characterization study of forward emission from a thin, meso-structured silica positron/positronium (Ps) converter following implantation of positrons in light of possible antihydrogen production is presented. The target consisted of a ∼1 μm thick ultraporous silica film e-gun evaporated onto a 20 nm carbon foil. The Ps formation and emission was studied via Single Shot Positron Annihilation Lifetime Spectroscopy measurements after implantation of pulses with 3 - 4 ·107 positrons and 10 ns temporal width. The forward emission of implanted positrons and secondary electrons was investigated with a micro-channel plate - phosphor screen assembly, connected either to a CCD camera for imaging of the impinging particles, or to a fast photomultiplier tube to extract information about their time of flight. The maximum Ps formation fraction was estimated to be ∼10%. At least 10% of the positrons implanted with an energy of 3.3 keV are forward-emitted with a scattering angle smaller than 50° and maximum kinetic energy of 1.2 keV. At least 0.1-0.2 secondary electrons per implanted positron were also found to be forward-emitted with a kinetic energy of a few eV. The possible application of this kind of positron/positronium converter for antihydrogen production is discussed.
Experimental studies of irradiated and hydrogen implantation damaged reactor steels
NASA Astrophysics Data System (ADS)
Slugeň, Vladimír; Pecko, Stanislav; Sojak, Stanislav
2016-01-01
Radiation degradation of nuclear materials can be experimentally simulated via ion implantation. In our case, German reactor pressure vessel (RPV) steels were studied by positron annihilation lifetime spectroscopy (PALS). This unique non-destructive method can be effectively applied for the evaluation of microstructural changes and for the analysis of degradation of reactor steels due to neutron irradiation and proton implantation. Studied specimens of German reactor pressure vessel steels are originally from CARINA/CARISMA program. Eight specimens were measured in as-received state and two specimens were irradiated by neutrons in German experimental reactor VAK (Versuchsatomkraftwerk Kahl) in the 1980s. One of the specimens which was in as-received and neutron irradiated condition was also used for simulation of neutron damage by hydrogen nuclei implantation. Defects with the size of about 1-2 vacancies with relatively small contribution (with intensity on the level of 20-40 %) were observed in "as-received" steels. A significant increase in the size of the induced defects due to neutron damage was observed in the irradiated specimens resulting in 2-3 vacancies. The size and intensity of defects reached a similar level as in the specimens irradiated in the nuclear reactor due to the implantation of hydrogen ions with energies of 100 keV (up to the depth <500 nm).
NASA Astrophysics Data System (ADS)
Pecko, Stanislav; Sojak, Stanislav; Slugeň, Vladimír
2014-09-01
Commercial German reactor pressure vessel (RPV) steels were studied by positron annihilation lifetime spectroscopy (PALS). This unique non-destructive method can be effectively applied for the evaluation of microstructural changes and for the analysis of degradation of reactor steels due to neutron irradiation and proton implantation. Studied specimens of German reactor pressure vessel steels are originally from CARINA/CARISMA program. Eight specimens were measured in as-received state and two specimens were irradiated by neutrons in German experimental reactor VAK (Versuchsatomkraftwerk Kahl) in the 1980s. One of the specimens which was also in as-received and neutron irradiated condition was also used for simulation of neutron damage by hydrogen nuclei implantation. Defects with the size of about 1-2 vacancies with relatively small contribution (with intensity on the level of 20-40%) were observed in "as-received" steels. A significant increase in the size of the induced defects due to neutron damage was observed at a level of 2-3 vacancies in the irradiated specimens. The size and intensity of defects reached a similar level as in the specimens irradiated in nuclear reactor due to hydrogen ions implantation with energy of 100 keV (up to the depth <500 nm). This could confirm the ability to simulate neutron damage by ion implantation.
Eap, Sandy; Keller, Laetitia; Schiavi, Jessica; Huck, Olivier; Jacomine, Leandro; Fioretti, Florence; Gauthier, Christian; Sebastian, Victor; Schwinté, Pascale; Benkirane-Jessel, Nadia
2015-01-01
New-generation implants focus on robust, durable, and rapid tissue regeneration to shorten recovery times and decrease risks of postoperative complications for patients. Herein, we describe a new-generation thick nanofibrous implant functionalized with active containers of growth factors and stem cells for regenerative nanomedicine. A thick electrospun poly(ε-caprolactone) nanofibrous implant (from 700 μm to 1 cm thick) was functionalized with chitosan and bone morphogenetic protein BMP-7 as growth factor using layer-by-layer technology, producing fish scale-like chitosan/BMP-7 nanoreservoirs. This extracellular matrix-mimicking scaffold enabled in vitro colonization and bone regeneration by human primary osteoblasts, as shown by expression of osteocalcin, osteopontin, and bone sialoprotein (BSPII), 21 days after seeding. In vivo implantation in mouse calvaria defects showed significantly more newly mineralized extracellular matrix in the functionalized implant compared to a bare scaffold after 30 days' implantation, as shown by histological scanning electron microscopy/energy dispersive X-ray microscopy study and calcein injection. We have as well bifunctionalized our BMP-7 therapeutic implant by adding human mesenchymal stem cells (hMSCs). The activity of this BMP-7-functionalized implant was again further enhanced by the addition of hMSCs to the implant (living materials), in vivo, as demonstrated by the analysis of new bone formation and calcification after 30 days' implantation in mice with calvaria defects. Therefore, implants functionalized with BMP-7 nanocontainers associated with hMSCs can act as an accelerator of in vivo bone mineralization and regeneration.
Zou, Duohong; Wu, Yiqun; Wang, Xu Dong; Huang, Wei; Zhang, Zhiyong; Zhang, Zhiyuan
2014-10-01
The aim of this study was to evaluate oral function rehabilitation in patients with hypohidrotic ectodermal dysplasia (HED) using implant-supported prostheses based on bone augmentation. From September 2005 and March 2009, 25 HED patients were chosen for clinical data analysis in this study. The criteria for patient selection included the following: the display of clinical features of HED, the number of congenitally missing teeth (>5), the patient age (>16 years), the patient's willingness, and the patient's tolerance for bone graft surgery and implant placement. Follow-up evaluations were initiated from the time of implant prosthetic placement and scheduled annually for 3-5 years. The effects of oral function reconstruction were assessed based on the cumulative survival and success rates of implants, the health of the peri-implant area, and the degree of patient satisfaction. Twenty-five HED patients received 169 conventional implants and 10 zygomatic implants (179 total implants). During 3-5 years of post-loading evaluations, 5 of the 179 implants failed and 3 implants were removed. The 3-year success and cumulative survival rates were 97.2% and 98.3%, respectively. Furthermore, periodontal probing and radiographic assessments showed that the 3-year incidence of peri-implantitis was 4.5%. Finally, HED patients expressed high degrees of satisfaction with their facial contours, masticatory function, pronunciation ability, and comfort with the implant-supported prostheses. The results of this 3- to 5-year retrospective study indicate that the oral function of HED patients can be effectively reconstructed using bone augmentation and implant-supported prostheses; however, longer term results are warranted in the future.
Yousif, Aziz; Kelly, Shawn K
2016-08-01
There has been a push for a greater number of channels in implantable neuroprosthetic devices; but, that number has largely been limited by current hermetic packaging technology. Microfabricated packaging is becoming reality, but a standard testing system is needed to prepare these devices for clinical trials. Impedance measurements of electrodes built into the packaging layers may give an early warning of device failure and predict device lifetime. Because the impedance magnitudes of such devices can be on the order of gigaohms, a versatile system was designed to accommodate ultra-high impedances and allow future integrated circuit implementation in current neural prosthetic technologies. Here we present the circuitry, control software, and preliminary testing results of our designed system.
FOREIGN BODY REACTION TO BIOMATERIALS
Anderson, James M.; Rodriguez, Analiz; Chang, David T.
2008-01-01
The foreign body reaction composed of macrophages and foreign body giant cells is the end-stage response of the inflammatory and wound healing responses following implantation of a medical device, prosthesis, or biomaterial. A brief, focused overview of events leading to the foreign body reaction is presented. The major focus of this review is on factors that modulate the interaction of macrophages and foreign body giant cells on synthetic surfaces where the chemical, physical, and morphological characteristics of the synthetic surface are considered to play a role in modulating cellular events. These events in the foreign body reaction include protein adsorption, monocyte/macrophage adhesion, macrophage fusion to form foreign body giant cells, consequences of the foreign body response on biomaterials, and cross-talk between macrophages/foreign body giant cells and inflammatory/wound healing cells. Biomaterial surface properties play an important role in modulating the foreign body reaction in the first two to four weeks following implantation of a medical device, even though the foreign body reaction at the tissue/material interface is present for the in vivo lifetime of the medical device. An understanding of the foreign body reaction is important as the foreign body reaction may impact the biocompatibility (safety) of the medical device, prosthesis, or implanted biomaterial and may significantly impact short- and long-term tissue responses with tissue-engineered constructs containing proteins, cells, and other biological components for use in tissue engineering and regenerative medicine. Our perspective has been on the inflammatory and wound healing response to implanted materials, devices, and tissue-engineered constructs. The incorporation of biological components of allogeneic or xenogeneic origin as well as stem cells into tissue-engineered or regenerative approaches opens up a myriad of other challenges. An in depth understanding of how the immune system interacts with these cells and how biomaterials or tissue-engineered constructs influences these interactions may prove pivotal to the safety, biocompatibility, and function of the device or system under consideration. PMID:18162407
Shang, Jianyuan; Geva, Eitan
2007-04-26
The quenching rate of a fluorophore attached to a macromolecule can be rather sensitive to its conformational state. The decay of the corresponding fluorescence lifetime autocorrelation function can therefore provide unique information on the time scales of conformational dynamics. The conventional way of measuring the fluorescence lifetime autocorrelation function involves evaluating it from the distribution of delay times between photoexcitation and photon emission. However, the time resolution of this procedure is limited by the time window required for collecting enough photons in order to establish this distribution with sufficient signal-to-noise ratio. Yang and Xie have recently proposed an approach for improving the time resolution, which is based on the argument that the autocorrelation function of the delay time between photoexcitation and photon emission is proportional to the autocorrelation function of the square of the fluorescence lifetime [Yang, H.; Xie, X. S. J. Chem. Phys. 2002, 117, 10965]. In this paper, we show that the delay-time autocorrelation function is equal to the autocorrelation function of the square of the fluorescence lifetime divided by the autocorrelation function of the fluorescence lifetime. We examine the conditions under which the delay-time autocorrelation function is approximately proportional to the autocorrelation function of the square of the fluorescence lifetime. We also investigate the correlation between the decay of the delay-time autocorrelation function and the time scales of conformational dynamics. The results are demonstrated via applications to a two-state model and an off-lattice model of a polypeptide.
Becker, B S; Bolton, J D
1997-12-01
Artificial hip joints have an average lifetime of 10 years due to aseptic loosening of the femoral stem attributed to polymeric wear debris; however, there is a steadily increasing demand from younger osteoarthritis patients aged between 15 and 40 year for a longer lasting joint of 25 years or more. Compliant layers incorporated into the acetabular cup generate elastohydrodynamic lubrication conditions between the bearing surfaces, reduce joint friction coefficients and wear debris production and could increase the average life of total hip replacements, and other human load-bearing joint replacements, i.e. total knee replacements. Poor adhesion between a fully dense substrate and the compliant layer has so far prevented any further exploitation. This work investigated the possibility of producing porous metallic, functionally gradient type acetabular cups using powder metallurgy techniques - where a porous surface was supported by a denser core - into which the compliant layers could be incorporated. The corrosion behaviour and mechanical properties of three biomedically approved alloys containing two levels of total porosity (>30% and <10%) were established, resulting in Ti-6Al-4V being identified as the most promising biocompatible functionally graded material, not only for this application but for other hard-tissue implants.
Eap, Sandy; Keller, Laetitia; Schiavi, Jessica; Huck, Olivier; Jacomine, Leandro; Fioretti, Florence; Gauthier, Christian; Sebastian, Victor; Schwinté, Pascale; Benkirane-Jessel, Nadia
2015-01-01
New-generation implants focus on robust, durable, and rapid tissue regeneration to shorten recovery times and decrease risks of postoperative complications for patients. Herein, we describe a new-generation thick nanofibrous implant functionalized with active containers of growth factors and stem cells for regenerative nanomedicine. A thick electrospun poly(ε-caprolactone) nanofibrous implant (from 700 μm to 1 cm thick) was functionalized with chitosan and bone morphogenetic protein BMP-7 as growth factor using layer-by-layer technology, producing fish scale-like chitosan/BMP-7 nanoreservoirs. This extracellular matrix-mimicking scaffold enabled in vitro colonization and bone regeneration by human primary osteoblasts, as shown by expression of osteocalcin, osteopontin, and bone sialoprotein (BSPII), 21 days after seeding. In vivo implantation in mouse calvaria defects showed significantly more newly mineralized extracellular matrix in the functionalized implant compared to a bare scaffold after 30 days’ implantation, as shown by histological scanning electron microscopy/energy dispersive X-ray microscopy study and calcein injection. We have as well bifunctionalized our BMP-7 therapeutic implant by adding human mesenchymal stem cells (hMSCs). The activity of this BMP-7-functionalized implant was again further enhanced by the addition of hMSCs to the implant (living materials), in vivo, as demonstrated by the analysis of new bone formation and calcification after 30 days’ implantation in mice with calvaria defects. Therefore, implants functionalized with BMP-7 nanocontainers associated with hMSCs can act as an accelerator of in vivo bone mineralization and regeneration. PMID:25709432
Gold, Michael R; Padhiar, Amie; Mealing, Stuart; Sidhu, Manpreet K; Tsintzos, Stelios I; Abraham, William T
2017-03-01
This study investigated the cost effectiveness of early cardiac resynchronization therapy (CRT) implantation among patients with mild heart failure (HF). The differential cost effectiveness between CRT using a defibrillator (CRT-Ds) and CRT using a pacemaker (CRT-P) was also assessed. Cardiac resynchronization has been shown to be cost effective in New York Heart Association (NYHA) functional classes III/IV but is less studied in class II HF. The incremental costs of early CRT implementation in mild HF compared with the costs potentially avoided because of delaying disease progression to advanced HF are also unknown. Finally, combined biventricular pacing and defibrillator (CRT-D) devices are more expensive than biventricular pacemakers (CRT-P), but the relative cost effectiveness is controversial. Data from the 5-year follow-up phase of REVERSE (REsynchronization reVErses Remodeling in Systolic Left vEntricular Dysfunction) were used. The economics were evaluated from the U.S. Medicare perspective based on published clinical projections. Probabilistic estimates yielded $8,840/quality-adjusted life year (QALY) gained (95% confidence interval [CI]: $6,705 to $10,804/QALY gained) for CRT-ON versus CRT-OFF (i.e., programmed "ON" or "OFF" at pre-specified post-implantation timings) and $43,678/QALY gained for CRT-D versus CRT-P (95% CI: $35,164 to $53,589/QALY gained) over the patient's lifetime. Results were robust to choice of patient subgroup and alterations of ±10% to key model parameters. An "early" CRT-D class II strategy totaled $95,292 compared with $91,511 for a "late" implantation. An "early" implant offered on average 1.00 year of additional survival for $3,781, resulting in an ICER of $3,795/LY gained. This study demonstrates CRT cost effectiveness in mild HF. The incremental CRT-D costs are justified by the anticipated benefits, despite increased procurement costs and shorter generator longevities. "Early" CRT-D implants have essential cost parity with "late" implants while increasing the patient's survival. (REsynchronization reVErses Remodeling in Systolic Left vEntricular Dysfunction [REVERSE]; NCT00271154). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bieth, C.; Bouly, J. L.; Curdy, J. C.; Kantas, S.; Sortais, P.; Sole, P.; Vieux-Rochaz, J. L.
2000-02-01
The electron cyclotron resonance (ECR) ion sources were originally developed for high energy physic applications. They are used as injectors on linear accelerators and cyclotrons to further increase the particle energy via high charge state ions. This ECR technology is well suited for sources placed on a high voltage platform where ac power available is limited by insulated transformers. The PANTECHNIK family of ion source with its wide range of ion beam (various charge states with various beam currents) offers new possibilities and perspectives in the field of ion implantation. In addition to all these possibilities, the PANTECHNIK ion sources have many other advantages like: a very long lifetime without maintenance expense, good stability, efficiency of ionization close to 100% (this improves the lifetime of the pumping system and other equipment), the possibility of producing ion beams with different energies, and a very good reproducibility. The main characteristics of sources like Nanogan or SuperNanogan will be recalled. We will especially present the results obtained with the new Microgan 10 GHz source that can be optimized for the production of high currents of monocharged ion, including reactive gas like BF3 (2 mA e of B+) or medium currents of low charge state like 0.5 mA e of Ar4+. The latest results obtained with Microgan 10 GHz show that it is possible to drive the source up to 30 mA e of total current, with an emittance of 150 π mm mrad at 40 kV and also to maintain the production of multicharged ions like Ar8+.
Er, Nilay; Alkan, Alper; Ilday, Serim; Bengu, Erman
2018-06-01
The dental implant drilling procedure is an essential step for implant surgery, and frictional heat in bone during drilling is a key factor affecting the success of an implant. The aim of this study was to increase the dental implant drill lifetime and performance by using heat- and wear-resistant protective coatings to decrease the alveolar bone temperature caused by the dental implant drilling procedure. Commercially obtained stainless steel drills were coated with titanium aluminum nitride, diamond-like carbon, titanium boron nitride, and boron nitride coatings via magnetron-sputter deposition. Drilling was performed on bovine femoral cortical bone under the conditions mimicking clinical practice. Tests were performed under water-assisted cooling and under the conditions when no cooling was applied. Coated drill performances and durabilities were compared with those of three commonly used commercial drills with surfaces made from zirconia, black diamond. and stainless steel. Protective coatings with boron nitride, titanium boron nitride, and diamond-like carbon have significantly improved drill performance and durability. In particular, boron nitride-coated drills have performed within safe bone temperature limits for 50 drillings even when no cooling is applied. Titanium aluminium nitride coated drills did not show any improvement over commercially obtained stainless steel drills. Surface modification using heat- and wear-resistant coatings is an easy and highly effective way to improve implant drill performance and durability, which can improve the surgical procedure and the postsurgical healing period. The noteworthy success of different types of coatings is novel and likely to be applicable to various other medical systems.
A Hermetic Wireless Subretinal Neurostimulator for Vision Prostheses
Shire, Douglas B.; Chen, Jinghua; Doyle, Patrick; Gingerich, Marcus D.; Cogan, Stuart F.; Drohan, William A.; Behan, Sonny; Theogarajan, Luke; Wyatt, John L.; Rizzo, Joseph F.
2016-01-01
A miniaturized, hermetically encased, wirelessly operated retinal prosthesis has been developed for preclinical studies in the Yucatan minipig, and includes several design improvements over our previously reported device. The prosthesis attaches conformally to the outside of the eye and electrically drives a microfabricated thin-film polyimide array of sputtered iridium oxide film electrodes. This array is implanted into the subretinal space using a customized ab externo surgical technique. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip and discrete circuit components. Feedthroughs in the case connect the stimulator chip to secondary power and data receiving coils on the eye and to the electrode array under the retina. Long-term in vitro pulse testing of the electrodes projected a lifetime consistent with typical devices in industry. The final assembly was tested in vitro to verify wireless operation of the system in physiological saline using a custom RF transmitter and primary coils. Stimulation pulse strength, duration, and frequency were programmed wirelessly from a Peripheral Component Interconnect eXtensions for Instrumentation (PXI) computer. Operation of the retinal implant has been verified in two pigs for up to five and a half months by detecting stimulus artifacts generated by the implanted device. PMID:21859595
Biocompatible medical implant materials with binding sites for a biodegradable drug-delivery system
Al-Dubai, Haifa; Pittner, Gisela; Pittner, Fritz; Gabor, Franz
2011-01-01
Feasibility studies have been carried out for development of a biocompatible coating of medical implant materials allowing the binding of biodegradable drug-delivery systems in a way that their reloading might be possible. These novel coatings, able to bind biodegradable nanoparticles, may serve in the long run as drug carriers to mediate local pharmacological activity. After biodegradation of the nanoparticles, the binding sites could be reloaded with fresh drug-delivering particles. As a suitable receptor system for the nanoparticles, antibodies are anchored. The design of the receptor is of great importance as any bio- or chemorecognitive interaction with other components circulating in the blood has to be avoided. Furthermore, the binding between receptor and the particles has to be strong enough to keep them tightly bound during their lifetime, but on the other hand allow reloading after final degradation of the particles. The nanoparticles suggested as a drug-delivery system for medical implants can be loaded with different pharmaceuticals such as antibiotics, growth factors, or immunosuppressives. This concept may enable the changing of medication, even after implantation of the medical device, if afforded by patients’ needs. PMID:24198488
Providência, Rui; Candeias, Rui; Morais, Carlos; Reis, Hipólito; Elvas, Luís; Sanfins, Vitor; Farinha, Sara; Eggington, Simon; Tsintzos, Stelios
2014-05-06
To estimate the short- and long-term financial impact of early referral for implantable loop recorder diagnostic (ILR) versus conventional diagnostic pathway (CDP) in the management of unexplained syncope (US) in the Portuguese National Health Service (PNHS). A Markov model was developed to estimate the expected number of hospital admissions due to US and its respective financial impact in patients implanted with ILR versus CDP. The average cost of a syncope episode admission was estimated based on Portuguese cost data and landmark papers. The financial impact of ILR adoption was estimated for a total of 197 patients with US, based on the number of syncope admissions per year in the PNHS. Sensitivity analysis was performed to take into account the effect of uncertainty in the input parameters (hazard ratio of death; number of syncope events per year; probabilities and unit costs of each diagnostic test; probability of trauma and yield of diagnosis) over three-year and lifetime horizons. The average cost of a syncope event was estimated to be between 1,760€ and 2,800€. Over a lifetime horizon, the total discounted costs of hospital admissions and syncope diagnosis for the entire cohort were 23% lower amongst patients in the ILR group compared with the CDP group (1,204,621€ for ILR, versus 1,571,332€ for CDP). The utilization of ILR leads to an earlier diagnosis and lower number of syncope hospital admissions and investigations, thus allowing significant cost offsets in the Portuguese setting. The result is robust to changes in the input parameter values, and cost savings become more pronounced over time.
Galvin, Karyn Louise; Holland, Jennifer Frances; Hughes, Kathryn Clare
2014-01-01
First, to document a broad range of functional outcomes of bilateral implantation for young children through young adults at a postoperative point at which stable outcomes could be expected. Second, to evaluate the relationship between functional outcomes and age at bilateral implantation and time between implants. A study-specific questionnaire was administered to parents in an interview 3.5 years or more after sequential (n = 50) or simultaneous (n = 7) implants were received by their child. Median age at bilateral implantation was 4.1 years (range 0.7 to 19.8) and time between implants was 2.7 years (range 0.0 to 16.7). On the basis of parent report, 72% of the sequentially implanted children and young adults found it easy/only "a bit difficult" to adapt to the second implant, and were "happily wearing both implants together most of the time" by 6 months or before; 26% had not adapted, with both implants not worn most of the time or worn as a parental requirement. Seventy-two percent of sequentially implanted children and young adults had a positive attitude toward the second implant, including 9 whose early postoperative attitude was negative or neutral. The majority of children and young adults preferred bilateral implants (70%) and used the two full time (72%), while around half demonstrated similar performance with each implant alone. The proportion of nonusers or very minimal users of the second implant was just 9%. Eighty-eight percent of parents reported superior performance with bilateral versus a unilateral implant (n = 40), or that only bilateral implants were worn (n = 10) so performance could not be compared. The most commonly identified areas of superiority were localization, less need for repetition, and increased responsiveness. In balancing risks and costs with benefits, most parents (86%) considered the second implant worthwhile. Regarding the relationship between outcomes and demographic factors, the group achieving similar performance with each implant alone was younger at bilateral implantation and had less time between implants, and the group bilaterally implanted before 3.5 years of age (who also had less than 2 years between implants) had a higher proportion of positive outcomes on all functional outcome measures. Overall, the results indicate primarily positive functional outcomes for children and young adults receiving bilateral implants at all ages, including when the delay between implants is long. The results are important for evidence-based preoperative counseling, which helps families to make informed decisions and develop appropriate expectations. The results are also important for the development of clinical management practices that support and encourage the minority of recipients who have difficulty adapting to bilateral implants or achieving full-time use.
Implant Removal After Internal Fixation of a Femoral Neck Fracture: Effects on Physical Functioning.
Zielinski, Stephanie M; Heetveld, Martin J; Bhandari, Mohit; Patka, Peter; Van Lieshout, Esther M M
2015-09-01
The effect of implant removal after internal fixation of a femoral neck fracture on physical functioning was analyzed. Characteristics of patients who had their implant removed were studied, as it is currently unknown from which type of patients implants are removed and what effect removal has on function. Secondary cohort study alongside a randomized controlled trial. Multicenter study in 14 hospitals. Patients who had their implant removed after internal fixation of a femoral neck fracture are compared with patients who did not. Patient characteristics and quality of life (Short Form 12, Western Ontario McMaster Osteoarthritis Index) were compared. Matched pairs were selected based on patient/fracture characteristics and prefracture physical functioning. Of 162 patients, 37 (23%) had their implant removed. These patients were younger (median age: 67 vs. 72 years, P = 0.024) and more often independently ambulatory prefracture (100% vs. 84%, P = 0.008) than patients who did not. They more often had evident implant back-out on x-rays (54% vs. 34%, P = 0.035), possibly related to a higher rate of Pauwels 3 fractures (41% vs. 22%, P = 0.032). In time, quality of life improved more in implant removal patients [+2 vs. -4 points, Short Form 12 (physical component), P = 0.024; +9 vs. 0 points, Western Ontario McMaster Osteoarthritis Index, P = 0.019]. Implant removal after internal fixation of a femoral neck fracture positively influenced quality of life. Implant removal patients were younger and more often independently ambulatory prefracture, more often had a Pauwels 3 fracture, and an evident implant back-out. Implant removal should be considered liberally for these patients if pain persists or functional recovery is unsatisfactory. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Wiefferink, Carin H; Rieffe, Carolien; Ketelaar, Lizet; Frijns, Johan H M
2012-06-01
The purpose of the present study was to compare children with a cochlear implant and normal hearing children on aspects of emotion regulation (emotion expression and coping strategies) and social functioning (social competence and externalizing behaviors) and the relation between emotion regulation and social functioning. Participants were 69 children with cochlear implants (CI children) and 67 normal hearing children (NH children) aged 1.5-5 years. Parents answered questionnaires about their children's language skills, social functioning, and emotion regulation. Children also completed simple tasks to measure their emotion regulation abilities. Cochlear implant children had fewer adequate emotion regulation strategies and were less socially competent than normal hearing children. The parents of cochlear implant children did not report fewer externalizing behaviors than those of normal hearing children. While social competence in normal hearing children was strongly related to emotion regulation, cochlear implant children regulated their emotions in ways that were unrelated with social competence. On the other hand, emotion regulation explained externalizing behaviors better in cochlear implant children than in normal hearing children. While better language skills were related to higher social competence in both groups, they were related to fewer externalizing behaviors only in cochlear implant children. Our results indicate that cochlear implant children have less adequate emotion-regulation strategies and less social competence than normal hearing children. Since they received their implants relatively recently, they might eventually catch up with their hearing peers. Longitudinal studies should further explore the development of emotion regulation and social functioning in cochlear implant children. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
DE Caluwé, Eva; VAN DE Bruaene, Alexander; Willems, Rik; Troost, Els; Gewillig, Marc; Rega, Filip; Budts, Werner
2016-09-01
Children from mothers with systemic lupus erythematosus are frequently born with congenital heart block. This study aimed at evaluating long-term outcome because long-term data are scarce. In the database of pediatric and congenital heart disease (University Hospitals Leuven), 19 children from systemic lupus erythematosus mothers and who were born with or developed atrioventricular block were identified. All records were reviewed for disease course and outcome. Median follow-up time was 7 years (interquartile ranges [IQR] 4.5-13 years). One child had no heart block at birth and developed only a first-degree block during follow-up. One had a second-degree heart block and developed a complete heart block. Seventeen patients (89%) were born with a complete heart block. Seventeen patients (89%) needed a definitive pacemaker. In all, epicardial leads were used at first implantation. Eighty-two percent received their pacemaker in the first year of life. The first battery had a median lifetime of 5 years (IQR 3.5-5 years), the second 6 years (IQR 4.5-6.3 years), and the third 5 years (IQR 5-6 years). Note that 47% of patients needed a lead replacement due to lead problems. Only one pericardial tamponade after pacemaker implantation. No device or lead infections occurred. The left ventricular systolic function at latest follow-up was normal for all. No patients died. In children with heart block born from systemic lupus erythematosus mothers, an early need for pacemaker implantation was documented. The overall battery life was acceptable, but there was a high need for lead replacement. Complication rate was low. Late outcome was good. © 2016 Wiley Periodicals, Inc.
Functional and Histological Effects of Chronic Neural Electrode Implantation.
Sahyouni, Ronald; Chang, David T; Moshtaghi, Omid; Mahmoodi, Amin; Djalilian, Hamid R; Lin, Harrison W
2017-04-01
Permanent injury to the cranial nerves can often result in a substantial reduction in quality of life. Novel and innovative interventions can help restore form and function in nerve paralysis, with bioelectric interfaces among the more promising of these approaches. The foreign body response is an important consideration for any bioelectric device as it influences the function and effectiveness of the implant. The purpose of this review is to describe tissue and functional effects of chronic neural implantation among the different categories of neural implants and highlight advances in peripheral and cranial nerve stimulation. Data Sources : PubMed, IEEE, and Web of Science literature search. Review Methods : A review of the current literature was conducted to examine functional and histologic effects of bioelectric interfaces for neural implants. Bioelectric devices can be characterized as intraneural, epineural, perineural, intranuclear, or cortical depending on their placement relative to nerves and neuronal cell bodies. Such devices include nerve-specific stimulators, neuroprosthetics, brainstem implants, and deep brain stimulators. Regardless of electrode location and interface type, acute and chronic histological, macroscopic and functional changes can occur as a result of both passive and active tissue responses to the bioelectric implant. A variety of chronically implantable electrodes have been developed to treat disorders of the peripheral and cranial nerves, to varying degrees of efficacy. Consideration and mitigation of detrimental effects at the neural interface with further optimization of functional nerve stimulation will facilitate the development of these technologies and translation to the clinic. 3.
Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula
Sierraalta, Marianella; Vivas, Jose L.; Razzoog, Michael E.; Wang, Rui-Feng
2012-01-01
Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to that of conventional cast frameworks. Material and Methods. Fifteen casts fabricated from a single edentulous CAD/CAM surgical guide were separated in two groups and resin patterns simulating the framework for a fixed complete denture developed. Five casts were sent to dental laboratories to invest, cast in a Palladium-Gold alloy and fit the framework. Ten casts had the resin pattern scanned for fabrication of milled bars in Titanium. Using measuring software, positions of implant replicas in the definitive model were recorded. The three dimensional spatial orientation of each implant replica was matched to the implant replica. Results. Results demonstrated the mean vertical gap of the Cast framework was 0.021 (+0.004) mm and 0.012 (0.002) mm determined by fixed and unfixed best-fit matching coordinate system. For Titanium frameworks they were 0.0037 (+0.0028) mm and 0.0024 (+0.0005) mm, respectively. Conclusions. Milled one-piece Titanium fixed complete denture frameworks provided a more accurate precision of fit then traditional cast frameworks. PMID:22550486
NASA Astrophysics Data System (ADS)
Yucesoy, Deniz T.; Hnilova, Marketa; Boone, Kyle; Arnold, Paul M.; Snead, Malcolm L.; Tamerler, Candan
2015-04-01
Implant-associated infections can have severe effects on the longevity of implant devices and they also represent a major cause of implant failures. Treating these infections associated with implants by antibiotics is not always an effective strategy due to poor penetration rates of antibiotics into biofilms. Additionally, emerging antibiotic resistance poses serious concerns. There is an urge to develop effective antibacterial surfaces that prevent bacterial adhesion and proliferation. A novel class of bacterial therapeutic agents, known as antimicrobial peptides (AMPs), are receiving increasing attention as an unconventional option to treat septic infection, partly due to their capacity to stimulate innate immune responses and for the difficulty of microorganisms to develop resistance towards them. While host and bacterial cells compete in determining the ultimate fate of the implant, functionalization of implant surfaces with AMPs can shift the balance and prevent implant infections. In the present study, we developed a novel chimeric peptide to functionalize the implant material surface. The chimeric peptide simultaneously presents two functionalities, with one domain binding to a titanium alloy implant surface through a titanium-binding domain while the other domain displays an antimicrobial property. This approach gains strength through control over the bio-material interfaces, a property built upon molecular recognition and self-assembly through a titanium alloy binding domain in the chimeric peptide. The efficiency of chimeric peptide both in-solution and absorbed onto titanium alloy surface was evaluated in vitro against three common human host infectious bacteria, Streptococcus mutans, Staphylococcus epidermidis, and Escherichia coli. In biological interactions such as occur on implants, it is the surface and the interface that dictate the ultimate outcome. Controlling the implant surface by creating an interface composed chimeric peptides may therefore open up new possibilities to modify the implant site and tailor it to a desirable bioactivity.
Di Carlo, Costantino; Sansone, Anna; De Rosa, Nicoletta; Gargano, Virginia; Tommaselli, Giovanni Antonio; Nappi, Carmine; Bifulco, Giuseppe
2014-01-01
The aim of the study was to determine the impact of etonogestrel (ENG)-implant used for contraceptive purpose on Quality of life (QoL) and on sexual function (FSF) of healthy Italian women. The Female Sexual Function Index (FSFI) questionnaire and the Short Form-36 (SF-36) validated questionnaire were administered at baseline, 3 and 6 months after insertion of Nexplanon. The implant seems to have a positive impact on QoL after the first three months of therapy. Users showed an improved general health status and physical role status. The implant did not show negative effects on libido and on sexual function. In the first three months of treatment, users experienced a temporary reduction of vitality, mental health, social functioning and emotional role functioning, which seem to disappear after six months of therapy.
Atluri, Pavan; Fairman, Alexander S.; MacArthur, John W.; Goldstone, Andrew B.; Cohen, Jeffrey E.; Howard, Jessica L.; Zalewski, Christyna M.; Shudo, Yasuhiro; Woo, Y. Joseph
2014-01-01
Background Continuous flow left ventricular assist devices (CF LVAD) are being implanted with increasing frequency for end-stage heart failure. At the time of LVAD implant, a large proportion of patients have pulmonary hypertension, right ventricular (RV) dysfunction, and tricuspid regurgitation (TR). RV dysfunction and TR can exacerbate renal dysfunction, hepatic dysfunction, coagulopathy, edema, and even prohibit isolated LVAD implant. Repairing TR mandates increased cardiopulmonary bypass time and bicaval cannulation, which should be reserved for the time of orthotopic heart transplantation. We hypothesized that CF LVAD implant would improve pulmonary artery pressures, enhance RV function, and minimize TR, obviating need for surgical tricuspid repair. Methods One hundred fourteen continuous flow LVADs implanted from 2005 through 2011 at a single center, with medical management of functional TR, were retrospectively analyzed. Pulmonary artery pressures were measured immediately prior to and following LVAD implant. RV function and TR were graded according to standard echocardiographic criteria, prior to, immediately following, and long-term following LVAD. Results There was a significant improvement in post-VAD mean pulmonary arterial pressures (26.6 ± 4.9 vs. 30.2 ± 7.4 mmHg, p = 0.008) with equivalent loading pressures (CVP = 12.0 ± 4.0 vs. 12.1 ± 5.1 p = NS). RV function significantly improved, as noted by right ventricular stroke work index (7.04 ± 2.60 vs. 6.05 ± 2.54, p = 0.02). There was an immediate improvement in TR grade and RV function following LVAD implant, which was sustained long term. Conclusion Continuous flow LVAD implant improves pulmonary hypertension, RV function, and tricuspid regurgitation. TR may be managed nonoperatively during CF LVAD implant. PMID:24118109
Mangano, Francesco; Mangano, Carlo; Piattelli, Adriano; Iezzi, Giovanna
2017-01-01
Direct metal laser sintering (DMLS) is an additive manufacturing technique that allows the fabrication of dental implants layer by layer through the laser fusion of titanium microparticles. The surface of DMLS implants is characterized by a high open porosity with interconnected pores of different sizes; therefore, it has the potential to enhance and accelerate bone healing. To date, however, there are no histologic/histomorphometric studies in the literature evaluating the interface between bone and DMLS implants in the long-term. To evaluate the interface between bone and DMLS implants retrieved after 5 years of functional loading. Two fractured DMLS implants were retrieved from the human jaws, using a 5 mm trephine bur. Both the implants were clinically stable and functioned regularly before fracture. The specimens were processed for histologic/histomorphometric evaluation; the bone-to-implant contact (BIC%) was calculated. Compact, mature lamellar bone was found over most of the DMLS implants in close contact with the implant surface; the histomorphometric evaluation showed a mean BIC% of 66.1% (±4.5%). The present histologic/histomorphometric study showed that DMLS implants were well integrated in bone, after 5 years of loading, with the peri-implant bone undergoing continuous remodeling at the interface.
Piattelli, Adriano
2017-01-01
Background Direct metal laser sintering (DMLS) is an additive manufacturing technique that allows the fabrication of dental implants layer by layer through the laser fusion of titanium microparticles. The surface of DMLS implants is characterized by a high open porosity with interconnected pores of different sizes; therefore, it has the potential to enhance and accelerate bone healing. To date, however, there are no histologic/histomorphometric studies in the literature evaluating the interface between bone and DMLS implants in the long-term. Purpose To evaluate the interface between bone and DMLS implants retrieved after 5 years of functional loading. Methods Two fractured DMLS implants were retrieved from the human jaws, using a 5 mm trephine bur. Both the implants were clinically stable and functioned regularly before fracture. The specimens were processed for histologic/histomorphometric evaluation; the bone-to-implant contact (BIC%) was calculated. Results Compact, mature lamellar bone was found over most of the DMLS implants in close contact with the implant surface; the histomorphometric evaluation showed a mean BIC% of 66.1% (±4.5%). Conclusions The present histologic/histomorphometric study showed that DMLS implants were well integrated in bone, after 5 years of loading, with the peri-implant bone undergoing continuous remodeling at the interface. PMID:28929117
Minority-carrier lifetime in InP as a function of light bias
NASA Technical Reports Server (NTRS)
Yater, Jane A.; Weinberg, I.; Jenkins, Phillip P.; Landis, Geoffrey A.
1995-01-01
Minority-carrier lifetime in InP is studied as a function of doping level and laser intensity using time-resolved photoluminescence. A continuous wave diode laser illuminates bulk InP and acts as a light bias, injecting a steady-state concentration of carriers. A 200 ps laser pulse produces a small transient signal on top of the steady-state luminescence, allowing lifetime to be measured directly as a function of incident intensity. For p-InP, lifetime increases with light bias up to a maximum value. Bulk recombination centers are presumably filled to saturation, allowing minority carriers to live longer. The saturation bias scales with dopant concentration for a particular dopant species. As light bias is increased for n-InP, minority-carrier lifetime increases slightly but then decreases, suggesting radiative recombination as a dominant decay mechanism.
A Satellite Mortality Study to Support Space Systems Lifetime Prediction
NASA Technical Reports Server (NTRS)
Fox, George; Salazar, Ronald; Habib-Agahi, Hamid; Dubos, Gregory
2013-01-01
Estimating the operational lifetime of satellites and spacecraft is a complex process. Operational lifetime can differ from mission design lifetime for a variety of reasons. Unexpected mortality can occur due to human errors in design and fabrication, to human errors in launch and operations, to random anomalies of hardware and software or even satellite function degradation or technology change, leading to unrealized economic or mission return. This study focuses on data collection of public information using, for the first time, a large, publically available dataset, and preliminary analysis of satellite lifetimes, both operational lifetime and design lifetime. The objective of this study is the illustration of the relationship of design life to actual lifetime for some representative classes of satellites and spacecraft. First, a Weibull and Exponential lifetime analysis comparison is performed on the ratio of mission operating lifetime to design life, accounting for terminated and ongoing missions. Next a Kaplan-Meier survivor function, standard practice for clinical trials analysis, is estimated from operating lifetime. Bootstrap resampling is used to provide uncertainty estimates of selected survival probabilities. This study highlights the need for more detailed databases and engineering reliability models of satellite lifetime that include satellite systems and subsystems, operations procedures and environmental characteristics to support the design of complex, multi-generation, long-lived space systems in Earth orbit.
Fiber-based time-resolved fluorescence and phosphorescence spectroscopy of tumors
NASA Astrophysics Data System (ADS)
Shirmanova, M.; Lukina, M.; Orlova, A.; Studier, H.; Zagaynova, E.; Becker, W.; Shcheslavskiy, V.
2017-07-01
The study of metabolic and oxygen states of cells in a tumor in vivo is crucial for understanding of the mechanisms responsible for the tumor development and provides background for the relevant tumor's treatment. Here, we show that a specially designed implantable fiber-optical probe provides a promising tool for optical interrogation of metabolic and oxygen states of a tumor in vivo. In our experiments, the excitation light from a ps diode laser source is delivered to the sample through an exchangeable tip via a multimode fiber, and the emission light is transferred to the detector by another multimode fiber. Fluorescence lifetime of nicotinamid adenine dinucleotide (NAD(P)H) and phosphorescence lifetime of an oxygen sensor based on iridium (III) complex of enzothienylpyridine (BTPDM1) are explored both in model experiment in solutions, and in living mice. The luminescence spectroscopy data is substantiated with immunohistochemistry experiments. To the best of our knowledge, the measurements of both metabolic status and oxygenation of tumor in vivo by fluorescence/phosphorescence lifetime spectroscopy with a fiber-optic probe are done for the first time.
Slot, Wim; Raghoebar, Gerry M; Cune, Marco S; Vissink, Arjan; Meijer, Henny J A
2016-12-01
To compare a four- and six-implant maxillary overdenture after an observation period of 5 years. Fifty subjects with functional problems concerning their maxillary denture, who had ample bone volume in the anterior region to place four or six implants, were included and randomly assigned to either group. Implant and overdenture survival, clinical performance, marginal bone loss and patient satisfaction were assessed. Forty-six patients completed the 5-year follow-up. One implant failed in the six implants group (99.2% survival) and none in the four implants group (100% survival). No overdentures had to be replaced during the observation period and the number of complications was limited. Clinical function was good, with no difference in clinical parameters between the groups. Mean marginal bone resorption was 0.50 ± 0.37 and 0.52 ± 0.43 mm in the four and six implant group respectively. In patients with functional complaints of their maxillary denture, bar-supported overdentures on four implants in the anterior maxillary region were not inferior to overdentures supported by six implants after 5 years of function. Implant survival and patient satisfaction were high, clinical parameters favourable, bone loss and complications to the denture were minor in both groups (Clinical trial registration number: NTR2969). © 2016 The Authors. Journal of Clinical Periodontology Published by John Wiley & Sons Ltd.
Antimicrobial and Antifouling Polymeric Agents for Surface Functionalization of Medical Implants.
Zeng, Qiang; Zhu, Yiwen; Yu, Bingran; Sun, Yujie; Ding, Xiaokang; Xu, Chen; Wu, Yu-Wei; Tang, Zhihui; Xu, Fu-Jian
2018-05-09
Combating implant-associated infections is an urgent demand due to the increasing numbers in surgical operations such as joint replacements and dental implantations. Surface functionalization of implantable medical devices with polymeric antimicrobial and antifouling agents is an efficient strategy to prevent bacterial fouling and associated infections. In this work, antimicrobial and antifouling branched polymeric agents (GPEG and GEG) were synthesized via ring-opening reaction involving gentamicin and ethylene glycol species. Due to their rich primary amine groups, they can be readily coated on the polydopamine-modified implant (such as titanium) surfaces. The resultant surface coatings of Ti-GPEG and Ti-GEG produce excellent in vitro antibacterial efficacy toward both Staphylococcus aureus and Escherichia coli, while Ti-GPEG exhibit better antifouling ability. Moreover, the infection model with S. aureus shows that implanted Ti-GPEG possessed excellent antibacterial and antifouling ability in vivo. This study would provide a promising strategy for the surface functionalization of implantable medical devices to prevent implant-associated infections.
Radiative lifetimes and cooling functions for astrophysically important molecules
NASA Astrophysics Data System (ADS)
Tennyson, Jonathan; Hulme, Kelsey; Naim, Omree K.; Yurchenko, Sergei N.
2016-02-01
Extensive line lists generated as part of the ExoMol project are used to compute lifetimes for individual rotational, rovibrational and rovibronic excited states, and temperature-dependent cooling functions by summing over all dipole-allowed transitions for the states concerned. Results are presented for SiO, CaH, AlO, ScH, H2O and methane. The results for CH4 are particularly unusual with four excited states with no dipole-allowed decay route and several others, where these decays lead to exceptionally long lifetimes. These lifetime data should be useful in models of masers and estimates of critical densities, and can provide a link with laboratory measurements. Cooling functions are important in stellar and planet formation.
Maló, Paulo; Friberg, Bertil; Polizzi, Giovanni; Gualini, Federico; Vighagen, Torbjörn; Rangert, Bo
2003-01-01
Immediate/early implant function means great benefits for patients and therapists because treatment time and cost can be substantially reduced. This concept has become an accepted alternative for complete arch fixed restorations in the mandible, and clinical documentation is emerging for other indications. The purpose of this prospective clinical multicenter study was to evaluate the outcome of implants placed in incisor, canine, and premolar regions in maxillas or mandibles. Implants were loaded with provisional crowns and bridges on the same day or within a few days and were followed up for 1 year during function. Four centers treated 76 patients each in need of an implant-retained prosthesis in the anterior and premolar regions in the maxilla or mandible. A total of 116 titanium implants with machined surfaces (Brånemark System , Nobel Biocare AB, Gothenburg, Sweden) were placed: 74 in maxillas and 42 in mandibles. Eighty-seven prostheses were made, of which 63 were single crowns and 24 were bridges (supported by 53 splinted implants). Twenty-two implants in 14 patients were placed in fresh extraction sites. The goal with the preparation and insertion technique was to achieve good primary implant stability and a minimum implant insertion torque of 30 Ncm before the implant was completely seated. The occlusion was adjusted to eliminate direct contact with the provisional prostheses. After 6 months, the patients received their permanent prostheses. Sixty-seven patients were followed for 1 year. Five implants were lost in five patients, three in the maxilla and two in the mandible. Four of the lost implants were single-tooth replacements and one was splinted. The cumulative survival rate (CSR) was 95.7% for all implants after 1 year and 93.7% and 98.1% for single-tooth and splinted implants, respectively. There were no implant losses in the extraction sites. The CSR of 96% at 1 year indicates that immediate function of Brånemark System implants placed in incisor to premolar regions in both jaws is a viable concept. More failures occurred with single-tooth replacements (6.3%) than with splinted implants (1.9%).
Zhang, Lei; Ding, Qian; Liu, Cunrui; Sun, Yannan; Xie, Qiufei; Zhou, Yongsheng
2016-01-01
This systematic review attempted to determine the survival rate of implants placed in bone flaps in jaw rehabilitation and the functional gains and the most common complications related to these implants. An electronic search was undertaken of PubMed, EMBASE, and CNKI records from 1990 through July 2014. Two independent examiners read the titles and abstracts of the results to identify studies that met the inclusion criteria. Subsequently, the reference lists of the selected publications were hand searched. Descriptive statistics were used to report all data related to the survival rate of implants placed in bone flaps in jaw rehabilitation, the functional gains, and complications. A total of 20 studies were included for systematic review without repetition. The mean follow-up time after implant placement ranged from 1.75 to 9.5 years. Within the limitations of available studies, the survival rate of implants placed in bone flaps in jaw rehabilitation ranged from 82.4% to 100%. Of the 20 included studies, 15 reported a survival rate higher than 90%. The cumulative survival rate was 93.2%, with the longest follow-up time being 12.9 years. The most common complications related to these implants were peri-implant bone resorption or peri-implant inflammation, and peri-implant soft tissue proliferation. The main factors associated with the survival rate of implants in bone flaps were reported as time of implant placement and radiotherapy. Despite some persistent soft tissue problems and implant loss, most patients reached a satisfactory functional and esthetic outcome, as evaluated by clinical examination and subjectively by the patients at interview. Implant-supported dental prosthetic rehabilitation in reconstructed jaws improved the quality of life in terms of speech, nutrition, oral competence, and facial appearance. Placement of implants in bone flaps in jaw rehabilitation was demonstrated to be a reliable technique with a high survival rate. Multicentered randomized controlled clinical trials and longer clinical studies should be undertaken in this area.
Possible sources of neuroprotection following subretinal silicon chip implantation in RCS rats
NASA Astrophysics Data System (ADS)
Pardue, Machelle T.; Phillips, Michael J.; Yin, Hang; Fernandes, Alcides; Cheng, Yian; Chow, Alan Y.; Ball, Sherry L.
2005-03-01
Current retinal prosthetics are designed to stimulate existing neural circuits in diseased retinas to create a visual signal. However, implantation of retinal prosthetics may create a neurotrophic environment that also leads to improvements in visual function. Possible sources of increased neuroprotective effects on the retina may arise from electrical activity generated by the prosthetic, mechanical injury due to surgical implantation, and/or presence of a chronic foreign body. This study evaluates these three neuroprotective sources by implanting Royal College of Surgeons (RCS) rats, a model of retinitis pigmentosa, with a subretinal implant at an early stage of photoreceptor degeneration. Treatment groups included rats implanted with active and inactive devices, as well as sham-operated. These groups were compared to unoperated controls. Evaluation of retinal function throughout an 18 week post-implantation period demonstrated transient functional improvements in eyes implanted with an inactive device at 6, 12 and 14 weeks post-implantation. However, the number of photoreceptors located directly over or around the implant or sham incision was significantly increased in eyes implanted with an active or inactive device or sham-operated. These results indicate that in the RCS rat localized neuroprotection of photoreceptors from mechanical injury or a chronic foreign body may provide similar results to subretinal electrical stimulation at the current output evaluated here.
Scientific evaluation and pricing of medical devices and associated procedures in France.
Gilard, Martine; Debroucker, Frederique; Dubray, Claude; Allioux, Yves; Aper, Eliane; Barat-Leonhardt, Valérie; Brami, Michèle; Carbonneil, Cédric; Chartier-Kastler, Emmanuel; Coqueblin, Claire; Fare, Sandrine; Giri, Isabelle; Goehrs, Jean-Marie; Levesque, Karine; Maugendre, Philippe; Parquin, François; Sales, Jean-Patrick; Szwarcensztein, Karine
2013-01-01
Medical devices are many and various, ranging from tongue spatulas to implantable or invasive devices and imaging machines; their lifetimes are short, between 18 months and 5 years, due to incessant incremental innovation; and they are operator-dependent: in general, the clinical user performs a fitting procedure (hip implant or pacemaker), a therapeutic procedure using a non-implantable invasive device (arrhythmic site ablation probe, angioplasty balloon, extension spondyloplasty system, etc.) or follow-up of an active implanted device (long-term follow-up of an implanted cardiac defibrillator or of a deep brain stimulator in Parkinson's patients). A round-table held during the XXVIII(th) Giens Workshops meeting focused on the methodology of scientific evaluation of medical devices and the associated procedures with a view to their pricing and financing by the French National Health Insurance system. The working hypothesis was that the available data-set was sufficient for and compatible with scientific evaluation with clinical benefit. Post-registration studies, although contributing to the continuity of assessment, were not dealt with. Moreover, the focus was restricted to devices used in health establishments, where the association between devices and technical medical procedures is optimally representative. An update of the multiple regulatory protocols governing medical devices and procedures is provided. Issues more specifically related to procedures as such, to non-implantable devices and to innovative devices are then dealt with, and the proposals and discussion points raised at the round-table for each of these three areas are presented. © 2013 Société Française de Pharmacologie et de Thérapeutique.
Economic Analysis of Screening Strategies for Rupture of Silicone Gel Breast Implants
Chung, Kevin C.; Malay, Sunitha; Shauver, Melissa J.; Kim, H. Myra
2012-01-01
Background In 2006, the U.S. Food and Drug Administration (FDA) recommended screening of all women with silicone gel breast implants with magnetic resonance imaging (MRI) three years after implantation and every two years thereafter to assess their integrity. The cost for these serial examinations over the lifetime of the breast implants is an added burden to insurance payers and to women. We perform an economic analysis to determine the most optimal screening strategies by considering the diagnostic accuracy of the screening tests, the costs of the tests and subsequent implant removal. Methods We determined aggregate/pooled values for sensitivity and specificity of the screening tests ultrasound (US) and MRI in detecting silicone breast implant ruptures from the data obtained from published literature. We compiled costs, based on Medicare reimbursements for 2011, for the following elements: imaging modalities, anesthesia and 3 surgical treatment options for detected ruptures. We used decision tree to compare three alternate screening strategies of US only, MRI only and US followed by MRI in asymptomatic and symptomatic women. Results The cost per rupture of screening and management of rupture with US in asymptomatic women was $1,090, whereas in symptomatic women it was $1,622. Similar cost for MRI in asymptomatic women was $2,067, whereas in symptomatic women it was $2,143. Similar cost for US followed by MRI in asymptomatic women was $637, whereas in symptomatic women it was $2,908. Conclusion Screening with US followed by MRI was optimal for asymptomatic women and screening with US was optimal for symptomatic women. PMID:22743887
Romanos, Georgios E
2014-01-01
There are benefits to be derived from the use of advanced surgical protocols in conjunction with immediate functional loading using various dental implant designs and implant-abutment connections. Clinical protocols with simultaneous bone grafting, immediate implant placement, and/or sinus augmentations when a shortened treatment period is needed are included in this report, with the aim of providing understanding of the main protocol characteristics and prerequisites for long-term success in implant dentistry. This article presents three clinical cases that illustrate possibilities for advanced immediate loading using different implant designs. It demonstrates treatment of severe bone defects and the facilitation of placing implants in regenerated bone that can be immediately loaded.
Wetzels, Jan Willem; Koole, Ron; Meijer, Gert J; de Haan, Anton F J; Merkx, Matthias A W; Speksnijder, Caroline M
2016-04-01
The timing of placement as well as the functional benefit of interforaminal implants in edentulous patients treated for oral cancer is unclear. Fifty-six patients were recruited at 2 institutions. In 1 institution, interforaminal implants were placed during ablative surgery, the other institution used conventional prosthodontics with optional placement of implants postsurgery (postponed-placement). Masticatory performance, bite force, and subjective masticatory function were assessed before and 6 months, 1 year, and 5 years after surgery. Implant-retained overdentures (IODs) demonstrated the highest bite force and the least problems with solid food and food choice. Masticatory performance was equal for IODs and conventional dentures. After 5 years, IODs from patients in the during-ablative-surgery cohort tend to have higher bite force and masticatory performance than those from patients in the postponed-placement cohort. IODs produce the highest overall masticatory function. Implant placement during ablative surgery seems to be functionally beneficial. © 2016 Wiley Periodicals, Inc. Head Neck 38: E2103-E2111, 2016. © 2016 Wiley Periodicals, Inc.
Kelly, J Robert; Rungruanganunt, Patchnee
2016-01-01
Zirconia is being widely used, at times apparently by simply copying a metal design into ceramic. Structurally, ceramics are sensitive to both design and processing (fabrication) details. The aim of this work was to examine four computer-aided design/computer-assisted manufacture (CAD/CAM) abutments using a modified International Standards Organization (ISO) implant fatigue protocol to determine performance as a function of design and processing. Two full zirconia and two hybrid (Ti-based) abutments (n = 12 each) were tested wet at 15 Hz at a variety of loads to failure. Failure probability distributions were examined at each load, and when found to be the same, data from all loads were combined for lifetime analysis from accelerated to clinical conditions. Two distinctly different failure modes were found for both full zirconia and Ti-based abutments. One of these for zirconia has been reported clinically in the literature, and one for the Ti-based abutments has been reported anecdotally. The ISO protocol modification in this study forced failures in the abutments; no implant bodies failed. Extrapolated cycles for 10% failure at 70 N were: full zirconia, Atlantis 2 × 10(7) and Straumann 3 × 10(7); and Ti-based, Glidewell 1 × 10(6) and Nobel 1 × 10(21). Under accelerated conditions (200 N), performance differed significantly: Straumann clearly outperformed Astra (t test, P = .013), and the Glidewell Ti-base abutment also outperformed Atlantis zirconia at 200 N (Nobel ran-out; t test, P = .035). The modified ISO protocol in this study produced failures that were seen clinically. The manufacture matters; differences in design and fabrication that influence performance cannot be discerned clinically.
White, Sean M.; Pittman, Chelsea R.; Hingorani, Ryan; Arora, Rajan; Esipova, Tatiana V.; Vinogradov, Sergei A.; Hughes, Christopher C.W.; Choi, Bernard
2014-01-01
Achieving adequate vascularization within implanted engineered tissues is a significant obstacle to maintaining viability and functionality. In vitro prevascularization of engineered tissues has been explored as a potential solution to this challenge. The traditional paradigm of in vitro prevascularization is to implant an engineered tissue with a preformed vascular network that is perfused after anastomosis with the host circulation. We investigated the efficacy of this strategy by implanting cell-dense prevascularized tissues created via cell-mediated contraction and composed of collagen and a collagen-fibrin mixture into dorsal window chambers surgically prepared on immunocompromised mice. We found that host-implant anastomosis takes place in 2–6 days and that perfusion of vessels within the implants is subsequently restricted by thrombosis. However, by day 7, a functional vascular network composed of host and implant vessels developed. Prevascularization enhanced intra-implant pO2 significantly as early as 2 days postimplantation, reaching a maximum of 55 mmHg by day 8, which was significantly greater than the maximum within cellularized control tissues (18 mmHg). By day 14, collagen tissues supported ∼0.51×109 implanted and host-derived cells per mL. Our findings elucidate key features of in vitro prevascularization that can be used toward the design of larger and more functionally complex engineered tissues. PMID:24593148
Yucesoy, Deniz T; Hnilova, Marketa; Boone, Kyle; Arnold, Paul M; Snead, Malcolm L; Tamerler, Candan
2015-04-01
Implant-associated infections can have severe effects on the longevity of implant devices and they also represent a major cause of implant failures. Treating these infections associated with implants by antibiotics is not always an effective strategy due to poor penetration rates of antibiotics into biofilms. Additionally, emerging antibiotic resistance poses serious concerns. There is an urge to develop effective antibacterial surfaces that prevent bacterial adhesion and proliferation. A novel class of bacterial therapeutic agents, known as antimicrobial peptides (AMP's), are receiving increasing attention as an unconventional option to treat septic infection, partly due to their capacity to stimulate innate immune responses and for the difficulty of microorganisms to develop resistance towards them. While host- and bacterial- cells compete in determining the ultimate fate of the implant, functionalization of implant surfaces with antimicrobial peptides can shift the balance and prevent implant infections. In the present study, we developed a novel chimeric peptide to functionalize the implant material surface. The chimeric peptide simultaneously presents two functionalities, with one domain binding to a titanium alloy implant surface through a titanium-binding domain while the other domain displays an antimicrobial property. This approach gains strength through control over the bio-material interfaces, a property built upon molecular recognition and self-assembly through a titanium alloy binding domain in the chimeric peptide. The efficiency of chimeric peptide both in-solution and absorbed onto titanium alloy surface was evaluated in vitro against three common human host infectious bacteria, S. mutans, S. epidermidis , and E. coli . In biological interactions such as occurs on implants, it is the surface and the interface that dictate the ultimate outcome. Controlling the implant surface by creating an interface composed chimeric peptides may therefore open up new possibilities to cover the implant site and tailor it to a desirable bioactivity.
NASA Astrophysics Data System (ADS)
Kojima, Kazunobu; Takashima, Shinya; Edo, Masaharu; Ueno, Katsunori; Shimizu, Mitsuaki; Takahashi, Tokio; Ishibashi, Shoji; Uedono, Akira; Chichibu, Shigefusa F.
2017-06-01
The photoluminescences of ion-implanted (I/I) and epitaxial Mg-doped GaN (GaN:Mg) are compared. The intensities and lifetimes of the near-band-edge and ultraviolet luminescences associated with a MgGa acceptor of I/I GaN:Mg were significantly lower and shorter than those of the epilayers, respectively. Simultaneously, the green luminescence (GL) became dominant. These emissions were quenched far below room temperature. The results indicate the generation of point defects common to GL and nonradiative recombination centers (NRCs) by I/I. Taking the results of positron annihilation measurement into account, N vacancies are the prime candidate to emit GL and create NRCs with Ga vacancies, (VGa) m (VN) n , as well as to inhibit p-type conductivity.
NASA Astrophysics Data System (ADS)
Dunn, James P.; Rolland, James L.; Grim, James S.; Machado, Reinaldo M.; Hartz, Christopher L.
2006-11-01
A beta level evaluation of the GASGUARD® SAS GGT Arsine ion implant dopant supply developed by Air Products and Chemicals, Inc. was conducted by Atmel Corporation. The evaluation included characterization of the normalized wafer yield, mass spectra, ionization efficiency, flow rate, beam current, extraction of usable material and cylinder lifetime. This new and novel sub-atmospheric dopant gas delivery system utilizes a unique electrochemical process, which can generate, on demand, high flows of arsine at a constant 400 torr pressure while limiting net inventory of arsine to only 1 gram. This paper illustrates how Atmel Corporation evaluated and released this new arsine dopant delivery system for commercial production and verified high delivery capacity, resulting in reduced gas costs and increased cylinder life compared to the traditional adsorbent based technology.
[Management of hearing impairment in adults].
Frachet, Bruno; Poncet-Wallet, Christine; Ernst, Imilie; Quéruel, Françoise; Eshraghi, Adrien
2009-10-20
Hearing impairment, mainly the deafness with possible distortions, assorted with tinnitus concerns about 4 million of the French population. It can be of variable severity. Deafness is an invisible disability until we must answer a question. The permanent improvement of the computer and microelectronics sciences benefit to the prosthetic devices: cochlear implants compensate for complete hearing loss, hearing aids are hidden by being miniaturized, being partially or totally implantable. The management of disability is not limited to this material part: human assistance and assistive devices are part of the armory. Rest to continue and to increase the financial support. This claim is obviously not specific to disability hearing although the hearing aid is only refunded 138 Euro per device for a unit cost from 1300 Euro to 2500 Euro with an observed lifetime of 4 or 5 years.
Basic concepts and techniques of dental implants.
Tagliareni, Jonathan M; Clarkson, Earl
2015-04-01
Dental implants provide completely edentulous and partial edentulous patients the function and esthetics they had with natural dentition. It is critical to understand and apply predictable surgical principles when treatment planning and surgically restoring edentulous spaces with implants. This article defines basic implant concepts that should be meticulously followed for predictable results when treating patients and restoring dental implants. Topics include biological and functional considerations, biomechanical considerations, preoperative assessments, medical history and risk assessments, oral examinations, radiographic examinations, contraindications, and general treatment planning options. Copyright © 2015 Elsevier Inc. All rights reserved.
Ten-year NEDO BVAD development program: moving forward to the clinical arena.
Motomura, Tadashi; Okubo, Hisashi; Oda, Takeshi; Ogawa, Daisuke; Okahisa, Toshiya; Igo, Stephen; Shinohara, Toshiyuki; Yamamoto, Yoshiro; Noguchi, Chikaya; Ishizuka, Tsukasa; Okamoto, Eiji; Nosé, Yukihiko
2006-01-01
Since 1995, the Baylor Group has been developing a totally implantable NEDO BVAD system. This 10-year program was completed in March 2005, and preparation for clinical trials is underway. This article summarizes the entire 10-year NEDO program and describes the strategy for clinical trials. The project aimed to achieve: (1) dual centrifugal pumps with the ability of full biventricular support, (2) a compact system implantable into small adults, (3) a totally implantable system with transcutaneous energy transmission system (TETS), (4) a durable system with a lifetime of over 5 years, and (5) a system free of thrombus and with minimal hemolysis. The final goals are to complete preclinical system evaluations and commence the clinical trials in the near future. In vitro studies have demonstrated a pump capacity of over 8.5 l/min and an Index of Hemolysis of <0.004 g/100 l. The pump-bearing life expectancy was over 5 years. To date, eight pumps endured in vivo studies of over 3 months without complications, including thromboembolic events. The in vitro endurance studies of eight pumps are longer than 1 year. There were no mechanical malfunctions or pump failure. A stepwise clinical trial is being planned: Step1, a wearable BVAD/VAD will be clinically studied; Step 2, the BVAD/VAD will be implanted intracorporeally without TETS; and, Step 3, a totally implantable system will be clinically evaluated. The NEDO BVAD system has completed preclinical testing. Clinical trial preparation is underway.
An all-diamond, hermetic electrical feedthrough array for a retinal prosthesis.
Ganesan, Kumaravelu; Garrett, David J; Ahnood, Arman; Shivdasani, Mohit N; Tong, Wei; Turnley, Ann M; Fox, Kate; Meffin, Hamish; Prawer, Steven
2014-01-01
The interface between medical implants and the human nervous system is rapidly becoming more and more complex. This rise in complexity is driving the need for increasing numbers of densely packed electrical feedthrough to carry signals to and from implanted devices. This is particularly crucial in the field of neural prosthesis where high resolution stimulating or recording arrays near peripheral nerves or in the brain could dramatically improve the performance of these devices. Here we describe a flexible strategy for implementing high density, high count arrays of hermetic electrical feedthroughs by forming conducting nitrogen doped nanocrystalline diamond channels within an insulating polycrystalline diamond substrate. A unique feature of these arrays is that the feedthroughs can themselves be used as stimulating electrodes for neural tissue. Our particular application is such a feedthrough, designed as a component of a retinal implant to restore vision to the blind. The hermeticity of the feedthroughs means that the array can also form part of an implantable capsule which can interface directly with internal electronic chips. The hermeticity of the array is demonstrated by helium leak tests and electrical and electrochemical characterisation of the feedthroughs is described. The nitrogen doped nanocrystalline diamond forming the electrical feedthroughs is shown to be non-cyctotoxic. New fabrication strategies, such as the one described here, combined with the exceptional biostability of diamond can be exploited to generate a range of biomedical implants that last for the lifetime of the user without fear of degradation.
Distribution of lifetimes for coronal soft X-ray bright points
NASA Technical Reports Server (NTRS)
Golub, L.; Krieger, A. S.; Vaiana, G. S.
1976-01-01
The lifetime 'spectrum' of X-ray bright points (XBPs) is measured for a sample of 300 such features using soft X-ray images obtained with the S-054 X-ray spectrographic telescope aboard Skylab. 'Spectrum' here is defined as a function which gives the relative number of XBPs having a specific lifetime as a function of lifetime. The results indicate that a two-lifetime exponential can be fit to the decay curves of XBPs, that the spectrum is heavily weighted toward short lifetimes, and that the number of features lasting 20 to 30 hr or more is greater than expected. A short-lived component with an average lifetime of about 8 hr and a long-lived 1.5-day component are consistently found along with a few features lasting 50 hr or more. An examination of differences among the components shows that features lasting 2 days or less have a broad heliocentric-latitude distribution while nearly all the longer-lived features are observed within 30 deg of the solar equator.
Implanted depleted uranium fragments cause soft tissue sarcomas in the muscles of rats.
Hahn, Fletcher F; Guilmette, Raymond A; Hoover, Mark D
2002-01-01
In this study, we determined the carcinogenicity of depleted uranium (DU) metal fragments containing 0.75% titanium in muscle tissues of rats. The results have important implications for the medical management of Gulf War veterans who were wounded with DU fragments and who retain fragments in their soft tissues. We compared the tissue reactions in rats to the carcinogenicity of a tantalum metal (Ta), as a negative foreign-body control, and to a colloidal suspension of radioactive thorium dioxide ((232)Th), Thorotrast, as a positive radioactive control. DU was surgically implanted in the thigh muscles of male Wistar rats as four squares (2.5 x 2.5 x 1.5 mm or 5.0 x 5.0 x 1.5 mm) or four pellets (2.0 x 1.0 mm diameter) per rat. Ta was similarly implanted as four squares (5.0 x 5.0 x 1.1 mm) per rat. Thorotrast was injected at two sites in the thigh muscles of each rat. Control rats had only a surgical implantation procedure. Each treatment group included 50 rats. A connective tissue capsule formed around the metal implants, but not around the Thorotrast. Radiographs demonstrated corrosion of the DU implants shortly after implantation. At later times, rarifactions in the radiographic profiles correlated with proliferative tissue responses. After lifetime observation, the incidence of soft tissue sarcomas increased significantly around the 5.0 x 5.0 mm squares of DU and the positive control, Thorotrast. A slightly increased incidence occurred in rats implanted with the 2.5 x 2.5 mm DU squares and with 5.0 x 5.0 mm squares of Ta. No tumors were seen in rats with 2.0 x 1.0 mm diameter DU pellets or in the surgical controls. These results indicate that DU fragments of sufficient size cause localized proliferative reactions and soft tissue sarcomas that can be detected with radiography in the muscles of rats. PMID:11781165
Paniello, Randal C; Brookes, Sarah; Bhatt, Neel K; Bijangi-Vishehsaraei, Khadijeh; Zhang, Hongji; Halum, Stacey
2017-12-08
Muscle progenitor cells (MPCs) can be isolated from muscle samples and grown to a critical mass in culture. They have been shown to survive and integrate when implanted into rat laryngeal muscles. In this study, the ability of MPC implants to enhance adductor function of reinnervated thyroarytenoid muscles was tested in a canine model. Animal study. Sternocleidomastoid muscle samples were harvested from three canines. Muscle progenitor cells were isolated and cultured to 10 7 cells over 4 to 5 weeks, then implanted into right thyroarytenoid muscles after ipsilateral recurrent laryngeal nerve transection and repair. The left sides underwent the same nerve injury, but no cells were implanted. Laryngeal adductor force was measured pretreatment and again 6 months later, and the muscles were harvested for histology. Muscle progenitor cells were successfully cultured from all dogs. Laryngeal adductor force measurements averaged 60% of their baseline pretreatment values in nonimplanted controls, 98% after implantation with MPCs, and 128% after implantation with motor endplate-enhanced MPCs. Histology confirmed that the implanted MPCs survived, became integrated into thyroarytenoid muscle fibers, and were in close contact with nerve endings, suggesting functional innervation. Muscle progenitor cells were shown to significantly enhance adductor function in this pilot canine study. Patient-specific MPC implantation could potentially be used to improve laryngeal function in patients with vocal fold paresis/paralysis, atrophy, and other conditions. Further experiments are planned. NA. Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Bai, Yixin; Zhou, Rui; Cao, Jianyun; Wei, Daqing; Du, Qing; Li, Baoqiang; Wang, Yaming; Jia, Dechang; Zhou, Yu
2017-07-01
The sub-microporous microarc oxidation (MAO) coating covered Ti implant with micro-scale gouges has been fabricated via a multi-step MAO process to overcome the compromised bone-implant integration. The as-prepared implant has been further mediated by post-heat treatment to compare the effects of -OH functional group and the nano-scale orange peel-like morphology on osseointegration. The bone regeneration, bone-implant contact interface, and biomechanical push-out force of the modified Ti implant have been discussed thoroughly in this work. The greatly improved push-out force for the MAO coated Ti implants with micro-scale gouges could be attributed to the excellent mechanical interlocking effect between implants and biologically meshed bone tissues. Attributed to the -OH functional group which promotes synostosis between the biologically meshed bone and the gouge surface of implant, the multi-step MAO process could be an effective strategy to improve the osseointegration of Ti implant. Copyright © 2017 Elsevier B.V. All rights reserved.
Wong, Z C; Fan, W Y; Chwee, T S; Sullivan, Michael B
2017-08-09
Fluorescence lifetimes were evaluated using TD-DFT under different approximations for the emitting molecule and various exchange-correlation functionals, such as B3LYP, BMK, CAM-B3LYP, LC-BLYP, M06, M06-2X, M11, PBE0, ωB97, ωB97X, LC-BLYP*, and ωB97X* where the range-separation parameters in the last two functionals were tuned in a non-empirical fashion. Changes in the optimised molecular geometries between the ground and electronically excited states were found to affect the quality of the calculated lifetimes significantly, while the inclusion of vibronic features led to further improvements over the assumption of a vertical electronic transition. The LC-BLYP* functional was found to return the most accurate fluorescence lifetimes with unsigned errors that are mostly within 1.5 ns of experimental values.
SPINELLI, D.; DE VICO, G.; SCHIAVETTI, R.; BONINO, M.; POZZI, A.; BOLLERO, P.; BARLATTANI, A.
2010-01-01
SUMMARY The severe atrophy of the jaws are a challenging therapeutic problem, since the increase in bone is necessary to allow the placement of a sufficient number of implants. Combining immediate functionalization with the concept of guided surgery they combine the advantages offered by the innovative surgical and prosthetic implant technique (All-on-Four®) with those of computer-assisted planning in cases of severe bone atrophy. The method used in this case report, combines these two concepts in a surgical and prosthetic protocol safe and effective for the immediate function of 4 implants to support a fixed prosthesis in completely edentulous subjects. The integration of technology with immediate function with the concept of computer-guided surgery for implant placement and rehabilitation of completely edentulous jaws is now a predictable treatment modality with implant survival comparable to the traditional protocols. PMID:23285381
Rasouli, Rahimeh; Barhoum, Ahmed; Uludag, Hasan
2018-05-10
The emerging field of nanostructured implants has enormous scope in the areas of medical science and dental implants. Surface nanofeatures provide significant potential solutions to medical problems by the introduction of better biomaterials, improved implant design, and surface engineering techniques such as coating, patterning, functionalization and molecular grafting at the nanoscale. This review is of an interdisciplinary nature, addressing the history and development of dental implants and the emerging area of nanotechnology in dental implants. After a brief introduction to nanotechnology in dental implants and the main classes of dental implants, an overview of different types of nanomaterials (i.e. metals, metal oxides, ceramics, polymers and hydrides) used in dental implant together with their unique properties, the influence of elemental compositions, and surface morphologies and possible applications are presented from a chemical point of view. In the core of this review, the dental implant materials, physical and chemical fabrication techniques and the role of nanotechnology in achieving ideal dental implants have been discussed. Finally, the critical parameters in dental implant design and available data on the current dental implant surfaces that use nanotopography in clinical dentistry have been discussed.
The effect of process conditions on the performance of epitaxial InP solar cells
NASA Technical Reports Server (NTRS)
Borrego, J. M.; Ghandi, S. K.
1991-01-01
Indium phosphide solar cells have a higher resistance to electron irradiation than Si or GaAs cells of comparable junction depth. As a result, there is much interest in the use of this material for space applications. Cells of this material were made in bulk InP by a number of techniques, including ion implantation, direct diffusion in sealed ampoules, and by open tube diffusion. However, it is generally considered that the epitaxial approach will be superior to all of these techniques. The epitaxy of InP is considerably more difficult than that of gallium arsenide, for a number of reasons. Perhaps the most important is the fact that the native oxides of Indium are extremely difficult to remove, as compared to that of Gallium. In addition, thermal treatments for the desorption of these oxides often result in the formation of phosphorus vacancies and free indium on the surface. Thus, inadequate sample preparation before epitaxy, poor reactor cleaning procedures, or poor transition procedures between the growth of successive layers, all give rise to trap phenomena and to high interface recombination velocities. Moreover, the lifetime of the grown material is dominated by the occurrence of native defects, so that it is a strong function of growth parameters. These problems are of special interest to the fabrication of solar cells, where long life-time, combined with the absence of traps, is highly desirable. A study of this problem is described using a non-invasive diagnostic technique which was developed.
Song, In-Seok; Lee, Mi-Ran; Ryu, Jae-Jun; Lee, Ui-Lyong
Dental implants positioned in severely atrophied anterior maxillae require esthetic or functional compromises. This case report describes the rehabilitation of a severely atrophied alveolar ridge with a three-dimensional (3D) computer-aided design/computer-aided manufacture (CAD/CAM) surgical guide. A 50-year-old woman had a severely atrophied anterior maxilla with unfavorably positioned dental implants. Functional and esthetic prosthodontic restoration was difficult to achieve. An anterior segmental osteotomy was planned to reposition the dental implants. A 3D surgical guide was designed for precise relocation of the segment. The surgical guide firmly grasped the impression copings of the dental implants, minimizing surgical errors. Three-dimensional gingival simulation was used preoperatively to estimate the appropriate position of the gingiva. Rigid fixation to the surrounding bone allowed immobilization of the implant-bone segment. Satisfactory esthetic and functional outcomes were attained 6 months after surgery. Finally, a severely atrophied alveolar ridge with unfavorably positioned dental implants was recovered with minimal esthetic and functional deterioration using gingival simulation and a 3D CAD/CAM surgical guide.
Pellicer-Chover, Hilario; Cervera-Ballester, Juan; Peñarrocha-Oltra, David; Bagán, Leticia; Peñarrocha-Diago, María
2016-01-01
Background To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm length of the zygomatic implants 12 months after prosthetic delivery. Results Twenty-two patients participated in the study, receiving 22 prostheses anchored on 148 implants (44 were zygomatic and 94 were conventional implants). The mean right and left prosthetic arm length was 5.9±2.4 mm and 6.1±2.7 mm, respectively, with no statistically significant differences between them (p=0.576). The mean scores referred to comfort/retention, speech, functionality and overall satisfaction were high - no correlation being found between prosthetic arm length and patient satisfaction (p=0.815). Conclusions No relationship could be identified between prosthetic arm length (palatal position) and patient satisfaction. Key words:Zygomatic implants, patient satisfaction, zygomatic prosthesis, prosthetic arm length. PMID:26946206
Aburahma, Samah K; Alzoubi, Firas Q; Hammouri, Hanan M; Masri, Amira
2015-02-01
To evaluate clinical outcomes, quality-adjusted life years (QALY), cost effectiveness and cost utility associated with VNS therapy in children with refractory epilepsy in a developing country. Retrospective review of all children who underwent VNS implantation at King Abdullah University Hospital and Jordan University Hospital in Jordan. Twenty eight patients (16 males) had implantation of the VNS therapy system between the years 2007 and 2011. Mean age at implantation was 9.4 years. Mean duration of epilepsy prior to implantation was 6.5 years. The most common seizure type was generalized tonic clonic seizures. Fifteen patients showed a 50% or more reduction in seizure frequency. There was a significant reduction in total number of seizures (p=0.002) and emergency room (ER) visits (p=0.042) after VNS therapy. Atonic seizures were more likely to respond than generalized tonic clonic seizures, p=0.034. Direct hospital costs prior to VNS implantation were analyzed in relation to ER visits and intensive care unit (ICU) admissions. Cost savings per patient did reduce the financial burden of the device by about 30%. There was a QALY gain per lifetime of 3.78 years for children and 1 year for adolescents. Response to VNS implantation in Jordan was favorable and similar to what has been previously reported. QALY gain and cost per QALY analysis were encouraging. Cost savings were related to reduction in seizure severity. In circumstances of limited resources as in developing countries, targeting patients with frequent utilization of health services would improve cost effectiveness. Copyright © 2014 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Hahn, Michael; Busse, Björn; Procop, Mathias; Zustin, Jozef; Amling, Michael; Katzer, Alexander
2017-10-01
Most resurfacing systems are manufactured from cobalt-chromium alloys with metal-on-metal (MoM) bearing couples. Because the quantity of particulate metal and corrosion products which can be released into the periprosthetic milieu is greater in MoM bearings than in metal-on-polyethylene (MoP) bearings, it is hypothesized that the quantity and distribution of debris released by the MoM components induce a compositional change in the periprosthetic bone. To determine the validity of this claim, nondestructive µ-X-ray fluorescence analysis was carried out on undecalcified histological samples from 13 femoral heads which had undergone surface replacement. These samples were extracted from the patients after gradient time points due to required revision surgery. Samples from nonintervened femoral heads as well as from a MoP resurfaced implant served as controls. Light microscopy and µ-X-ray fluorescence analyses revealed that cobalt debris was found not only in the soft tissue around the prosthesis and the bone marrow, but also in the mineralized bone tissue. Mineralized bone exposed to surface replacements showed significant increases in cobalt concentrations in comparison with control specimens without an implant. A maximum cobalt concentration in mineralized hard tissue of up to 380 ppm was detected as early as 2 years after implantation. Values of this magnitude are not found in implants with a MoP surface bearing until a lifetime of more than 20 years. This study demonstrates that hip resurfacing implants with MoM bearings present a potential long-term health risk due to rapid cobalt ion accumulation in periprosthetic hard tissue. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1855-1862, 2017. © 2016 Wiley Periodicals, Inc.
MEYNARDI, F.; PASQUALINI, M.E.; ROSSI, F.; DAL CARLO, L.; NARDONE, M.; BAGGI, L.
2016-01-01
SUMMARY Purpose To assess the changes in bacterial profile along the transmucosal path of healing screws placed immediately after insertion of two-piece endosseus implants during the 4-month osseointegration phase, in absence of functional load. Materials and methods Two site-specific samples were collected at the peri-implant mucosa of the healing screws of 80 two-piece implants, for a total of 640 samples. Implants placement was performed following a single protocol with flapless technique, in order to limit bacterial contamination of the surgical site. Identical healing screws (5 mm diameter/4 mm height) were used for each of the 80 implants. During the 4 months of the study, the patients followed a standard oral care regimen with no special hygiene maneuvers at the collection sites. Results The present research documents that during the 4-month period prior to application of function load the bacterial profile of all sites exhibited a clear prevalence of cocci at the interface between implant neck and osteoalveolar crest margin. Conclusions A potentially pathogenic bacterial flora developed only along the peri-implant transmucosal path. PMID:28280528
Characterisation of irradiation-induced defects in ZnO single crystals
NASA Astrophysics Data System (ADS)
Prochazka, I.; Cizek, J.; Lukac, F.; Melikhova, O.; Valenta, J.; Havranek, V.; Anwand, W.; Skuratov, V. A.; Strukova, T. S.
2016-01-01
Positron annihilation spectroscopy (PAS) combined with optical methods was employed for characterisation of defects in the hydrothermally grown ZnO single crystals irradiated by 167 MeV Xe26+ ions to fluences ranged from 3×1012 to 1×1014 cm-2. The positron lifetime (LT), Doppler broadening as well as slow-positron implantation spectroscopy (SPIS) techniques were involved. The ab-initio theoretical calculations were utilised for interpretation of LT results. The optical transmission and photoluminescence measurements were conducted, too. The virgin ZnO crystal exhibited a single component LT spectrum with a lifetime of 182 ps which is attributed to saturated positron trapping in Zn vacancies associated with hydrogen atoms unintentionally introduced into the crystal during the crystal growth. The Xe ion irradiated ZnO crystals have shown an additional component with a longer lifetime of ≈ 360 ps which comes from irradiation-induced larger defects equivalent in size to clusters of ≈10 to 12 vacancies. The concentrations of these clusters were estimated on the basis of combined LT and SPIS data. The PAS data were correlated with irradiation induced changes seen in the optical spectroscopy experiments.
NASA Astrophysics Data System (ADS)
Ling, C. C.; Shek, Y. F.; Huang, A. P.; Fung, S.; Beling, C. D.
1999-02-01
Positron-lifetime spectroscopy has been used to investigate the electric-field distribution occurring at the Au-semi-insulating GaAs interface. Positrons implanted from a 22Na source and drifted back to the interface are detected through their characteristic lifetime at interface traps. The relative intensity of this fraction of interface-trapped positrons reveals that the field strength in the depletion region saturates at applied biases above 50 V, an observation that cannot be reconciled with a simple depletion approximation model. The data, are, however, shown to be fully consistent with recent direct electric-field measurements and the theoretical model proposed by McGregor et al. [J. Appl. Phys. 75, 7910 (1994)] of an enhanced EL2+ electron-capture cross section above a critical electric field that causes a dramatic reduction of the depletion region's net charge density. Two theoretically derived electric field profiles, together with an experimentally based profile, are used to estimate a positron mobility of ~95+/-35 cm2 V-1 s-1 under the saturation field. This value is higher than previous experiments would suggest, and reasons for this effect are discussed.
Walter, Kimberly N; Petry, Nancy M
2016-05-01
This cross-sectional study evaluated lifetime prevalence of suicide attempts in 170 HIV/AIDS patients with substance use disorders and the impact of suicide attempt history on subjective indices of quality of life and objective indices of cognitive and physical functioning. All patients met the diagnostic criteria for past-year cocaine or opioid use disorders and 27% of patients also had co-occurring alcohol use disorders. Compared to their counterparts without a history of a suicide attempt, patients with a history of a suicide attempt (n = 60, 35.3%) had significantly poorer emotional and cognitive quality of life scores (ps < .05), but not physical, social, or functional/global quality-of-life scores. Lifetime suicide attempt status was unrelated to objective indices of cognitive functioning, but there was a non-significant trend (p = .07) toward lower viral loads in those with a lifetime suicide attempt relative to those without. The findings indicate that suicide attempt histories are prevalent among HIV/AIDS patients with substance use disorders and relate to poorer perceived emotional and cognitive quality of life, but not objective functioning. HIV/AIDS patients with substance use disorders should be screened for lifetime histories of suicide attempts and offered assistance to improve perceived emotional and cognitive functioning. © The Author(s) 2016.
Chang, Po-Chun; Seol, Yang-Jo; Goldstein, Steven A.; Giannobile, William V.
2014-01-01
Purpose It is currently a challenge to determine the biomechanical properties of the hard tissue–dental implant interface. Recent advances in intraoral imaging and tomographic methods, such as microcomputed tomography (micro-CT), provide three-dimensional details, offering significant potential to evaluate the bone-implant interface, but yield limited information regarding osseointegration because of physical scattering effects emanating from metallic implant surfaces. In the present study, it was hypothesized that functional apparent moduli (FAM), generated from functional incorporation of the peri-implant structure, would eliminate the radiographic artifact–affected layer and serve as a feasible means to evaluate the biomechanical dynamics of tissue-implant integration in vivo. Materials and Methods Cylindric titanium mini-implants were placed in osteotomies and osteotomies with defects in rodent maxillae. The layers affected by radiographic artifacts were identified, and the pattern of tissue-implant integration was evaluated from histology and micro-CT images over a 21-day observation period. Analyses of structural information, FAM, and the relationship between FAM and interfacial stiffness (IS) were done before and after eliminating artifacts. Results Physical artifacts were present within a zone of about 100 to 150 μm around the implant in both experimental defect situations (osteotomy alone and osteotomy + defect). All correlations were evaluated before and after eliminating the artifact-affected layers, most notably during the maturation period of osseointegration. A strong correlation existed between functional bone apparent modulus and IS within 300 μm at the osteotomy defects (r > 0.9) and functional composite tissue apparent modulus in the osteotomy defects (r > 0.75). Conclusion Micro-CT imaging and FAM were of value in measuring the temporal process of tissue-implant integration in vivo. This approach will be useful to complement imaging technologies for longitudinal monitoring of osseointegration. PMID:23377049
Seo, Songwon; Lee, Dal Nim; Jin, Young Woo; Lee, Won Jin; Park, Sunhoo
2018-05-11
Risk projection models estimating the lifetime cancer risk from radiation exposure are generally based on exposure dose, age at exposure, attained age, gender and study-population-specific factors such as baseline cancer risks and survival rates. Because such models have mostly been based on the Life Span Study cohort of Japanese atomic bomb survivors, the baseline risks and survival rates in the target population should be considered when applying the cancer risk. The survival function used in the risk projection models that are commonly used in the radiological protection field to estimate the cancer risk from medical or occupational exposure is based on all-cause mortality. Thus, it may not be accurate for estimating the lifetime risk of high-incidence but not life-threatening cancer with a long-term survival rate. Herein, we present the lifetime attributable risk (LAR) estimates of all solid cancers except thyroid cancer, thyroid cancer, and leukemia except chronic lymphocytic leukemia in South Korea for lifetime exposure to 1 mGy per year using the cancer-free survival function, as recently applied in the Fukushima health risk assessment by the World Health Organization. Compared with the estimates of LARs using an overall survival function solely based on all-cause mortality, the LARs of all solid cancers except thyroid cancer, and thyroid cancer evaluated using the cancer-free survival function, decreased by approximately 13% and 1% for men and 9% and 5% for women, respectively. The LAR of leukemia except chronic lymphocytic leukemia barely changed for either gender owing to the small absolute difference between its incidence and mortality. Given that many cancers have a high curative rate and low mortality rate, using a survival function solely based on all-cause mortality may cause an overestimation of the lifetime risk of cancer incidence. The lifetime fractional risk was robust against the choice of survival function.
Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns
Buergers, Ralf; Ziebolz, Dirk; Roediger, Matthias
2015-01-01
PURPOSE This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: 5.9 ± 2.2 years), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required. PMID:26330981
Artificial vision: needs, functioning, and testing of a retinal electronic prosthesis.
Chader, Gerald J; Weiland, James; Humayun, Mark S
2009-01-01
Hundreds of thousands around the world have poor vision or no vision at all due to inherited retinal degenerations (RDs) like retinitis pigmentosa (RP). Similarly, millions suffer from vision loss due to age-related macular degeneration (AMD). In both of these allied diseases, the primary target for pathology is the retinal photoreceptor cells that dysfunction and die. Secondary neurons though are relatively spared. To replace photoreceptor cell function, an electronic prosthetic device can be used such that retinal secondary neurons receive a signal that simulates an external visual image. The composite device has a miniature video camera mounted on the patient's eyeglasses, which captures images and passes them to a microprocessor that converts the data to an electronic signal. This signal, in turn, is transmitted to an array of electrodes placed on the retinal surface, which transmits the patterned signal to the remaining viable secondary neurons. These neurons (ganglion, bipolar cells, etc.) begin processing the signal and pass it down the optic nerve to the brain for final integration into a visual image. Many groups in different countries have different versions of the device, including brain implants and retinal implants, the latter having epiretinal or subretinal placement. The device furthest along in development is an epiretinal implant sponsored by Second Sight Medical Products (SSMP). Their first-generation device had 16 electrodes with human testing in a Phase 1 clinical trial beginning in 2002. The second-generation device has 60+ electrodes and is currently in Phase 2/3 clinical trial. Increased numbers of electrodes are planned for future versions of the device. Testing of the device's efficacy is a challenge since patients admitted into the trial have little or no vision. Thus, methods must be developed that accurately and reproducibly record small improvements in visual function after implantation. Standard tests such as visual acuity, visual field, electroretinography, or even contrast sensitivity may not adequately capture some aspects of improvement that relate to a better quality of life (QOL). Because of this, some tests are now relying more on "real-world functional capacity" that better assesses possible improvement in aspects of everyday living. Thus, a new battery of tests have been suggested that include (1) standard psychophysical testing, (2) performance in tasks that are used in real-life situations such as object discrimination, mobility, etc., and (3) well-crafted questionnaires that assess the patient's own feelings as to the usefulness of the device. In the Phase 1 trial of the SSMP 16-electrode device, six subjects with severe RP were implanted with ongoing, continuing testing since then. First, it was evident that even limited sight restoration is a slow, learning process that takes months for improvement to become evident. However, light perception was restored in all six patients. Moreover, all subjects ultimately saw discrete phosphenes and could perform simple visual spatial and motion tasks. As mentioned above, a Phase 2/3 trial is now ongoing with a 60+ device. A 250+ device is on the drawing board, and one with over 1000 electrodes is being planned. Each has the possibility of significantly improving a patient's vision and QOL, being smaller and safer in design and lasting for the lifetime of the patient. From theoretical modeling, it is estimated that a device with approximately 1000 electrodes could give good functional vision, i.e., face recognition and reading ability. This could be a reality within 5-10 years from now. In summary, no treatments are currently available for severely affected patients with RP and dry AMD. An electrical prosthetic device appears to offer hope in replacing the function of degenerating or dead photoreceptor neurons. Devices with new, sophisticated designs and increasing numbers of electrodes could allow for long-term restoration of functional sight in patients with improvement in object recognition, mobility, independent living, and general QOL.
Cost Analysis of Ceramic Heads in Primary Total Hip Arthroplasty.
Carnes, Keith J; Odum, Susan M; Troyer, Jennifer L; Fehring, Thomas K
2016-11-02
The advent of adverse local tissue reactions seen in metal-on-metal bearings, and the recent recognition of trunnionosis, have led many surgeons to recommend ceramic-on-polyethylene articulations for primary total hip arthroplasty. However, to our knowledge, there has been little research that has considered whether the increased cost of ceramic provides enough benefit over cobalt-chromium to justify its use. The primary purpose of this study was to compare the cost-effectiveness of ceramic-on-polyethylene implants and metal-on-polyethylene implants in patients undergoing total hip arthroplasty. Markov decision modeling was used to determine the ceramic-on-polyethylene implant revision rate necessary to be cost-effective compared with the revision rate of metal-on-polyethylene implants across a range of patient ages and implant costs. A different set of Markov models was used to estimate the national cost burden of choosing ceramic-on-polyethylene implants over metal-on-polyethylene implants for primary total hip arthroplasties. The Premier Research Database was used to identify 20,398 patients who in 2012 were ≥45 years of age and underwent a total hip arthroplasty with either a ceramic-on-polyethylene implant or a metal-on-polyethylene implant. The cost-effectiveness of ceramic heads is highly dependent on the cost differential between ceramic and metal femoral heads and the age of the patient. At a cost differential of $325, ceramic-on-polyethylene bearings are cost-effective for patients <85 years of age. At a cost differential of $600, it is cost-effective to utilize ceramic-on-polyethylene bearings in patients <65 years of age, and, at a differential of $1,003, ceramic-on-polyethylene bearings are not cost-effective at any age. The ability to recoup the initial increased expenditure of ceramic heads through a diminished lifetime revision cost is dependent on the price premium for ceramic and the age of the patient. A wholesale switch to ceramic bearings regardless of age or cost differential may result in an economic burden to the health system. Economic and decision analysis, Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis.
Ferlauto, Laura; Airaghi Leccardi, Marta Jole Ildelfonsa; Chenais, Naïg Aurelia Ludmilla; Gilliéron, Samuel Charles Antoine; Vagni, Paola; Bevilacqua, Michele; Wolfensberger, Thomas J; Sivula, Kevin; Ghezzi, Diego
2018-03-08
Retinal prostheses have been developed to fight blindness in people affected by outer retinal layer dystrophies. To date, few hundred patients have received a retinal implant. Inspired by intraocular lenses, we have designed a foldable and photovoltaic wide-field epiretinal prosthesis (named POLYRETINA) capable of stimulating wireless retinal ganglion cells. Here we show that within a visual angle of 46.3 degrees, POLYRETINA embeds 2215 stimulating pixels, of which 967 are in the central area of 5 mm, it is foldable to allow implantation through a small scleral incision, and it has a hemispherical shape to match the curvature of the eye. We demonstrate that it is not cytotoxic and respects optical and thermal safety standards; accelerated ageing shows a lifetime of at least 2 years. POLYRETINA represents significant progress towards the improvement of both visual acuity and visual field with the same device, a current challenging issue in the field.
NASA Astrophysics Data System (ADS)
Uedono, A.; Inumiya, S.; Matsuki, T.; Aoyama, T.; Nara, Y.; Ishibashi, S.; Ohdaira, T.; Suzuki, R.; Miyazaki, S.; Yamada, K.
2007-09-01
Vacancy-fluorine complexes in metal-oxide semiconductors (MOS) with high-k gate dielectrics were studied using a positron annihilation technique. F+ ions were implanted into Si substrates before the deposition of gate dielectrics (HfSiON). The shift of threshold voltage (Vth) in MOS capacitors and an increase in Fermi level position below the HfSiON/Si interface were observed after F+ implantation. Doppler broadening spectra of the annihilation radiation and positron lifetimes were measured before and after HfSiON fabrication processes. From a comparison between Doppler broadening spectra and those obtained by first-principles calculation, the major defect species in Si substrates after annealing treatment (1050 °C, 5 s) was identified as vacancy-fluorine complexes (V3F2). The origin of the Vth shift in the MOS capacitors was attributed to V3F2 located in channel regions.
Lifetime depression history and sexual function in women at midlife.
Cyranowski, Jill M; Bromberger, Joyce; Youk, Ada; Matthews, Karen; Kravitz, Howard M; Powell, Lynda H
2004-12-01
We examined the association between lifetime depression history and sexual function in a community-based sample of midlife women. Specifically, 914 women aged 42-52 who were participants in the Study of Women's Health Across the Nation completed a self-report assessment of their sexual behaviors, sexual desire, sexual arousal, and sexual satisfaction over the past 6 months. On the basis of the Structured Clinical Interview for the DSM-IV , participants were categorized into 1 of 3 lifetime major depressive disorder (MDD) history groups: no MDD history, single episode MDD, and recurrent MDD. In line with previous reports, women with a history of recurrent MDD reported experiencing less frequent sexual arousal, less physical pleasure, and less emotional satisfaction within their current sexual relationships. Although the groups did not differ in their reported frequency of sexual desire or partnered sexual behaviors, lifetime depression history was associated with increased rates of self-stimulation (masturbation). Associations between lifetime depression history and lower levels of physical pleasure within partnered sexual relationships and higher rates of masturbation remained significant following control for current depressive symptoms, study site, marital status, psychotropic medication use, and lifetime history of anxiety or substance abuse/dependence disorder. Future research is needed to characterize the temporal and etiologic relationships among lifetime depressive disorder, current mood state, and sexual function in women across the lifespan.
Baltacıoğlu, Esra; Korkmaz, Fatih Mehmet; Bağış, Nilsun; Aydın, Güven; Yuva, Pınar; Korkmaz, Yavuz Tolga; Bağış, Bora
2014-01-01
This case report presents an implant-aided prosthetic treatment in which peri-implant plastic surgery techniques were applied in combination to satisfactorily attain functional aesthetic expectations. Peri-implant plastic surgery enables the successful reconstruction and restoration of the balance between soft and hard tissues and allows the option of implant-aided fixed prosthetic rehabilitation. PMID:25489351
Vallejo-Heligon, Suzana G; Brown, Nga L; Reichert, William M; Klitzman, Bruce
2016-01-01
Continuous glucose sensors offer the promise of tight glycemic control for insulin dependent diabetics; however, utilization of such systems has been hindered by issues of tissue compatibility. Here we report on the in vivo performance of implanted glucose sensors coated with Dexamethasone-loaded (Dex-loaded) porous coatings employed to mediate the tissue-sensor interface. Two animal studies were conducted to (1) characterize the tissue modifying effects of the porous Dex-loaded coatings deployed on sensor surrogate implants and (2) investigate the effects of the same coatings on the in vivo performance of Medtronic MiniMed SOF-SENSOR™ glucose sensors. The tissue response to implants was evaluated by quantifying macrophage infiltration, blood vessel formation, and collagen density around implants. Sensor function was assessed by measuring changes in sensor sensitivity and time lag, calculating the Mean Absolute Relative Difference (MARD) for each sensor treatment, and performing functional glucose challenge test at relevant time points. Implants treated with porous Dex-loaded coatings diminished inflammation and enhanced vascularization of the tissue surrounding the implants. Functional sensors with Dex-loaded porous coatings showed enhanced sensor sensitivity over a 21-day period when compared to controls. Enhanced sensor sensitivity was accompanied with an increase in sensor signal lag and MARD score. These results indicate that Dex-loaded porous coatings were able to elicit an attenuated tissue response, and that such tissue microenvironment could be conducive towards extending the performance window of glucose sensors in vivo. In the present article, a coating to extend the functionality of implantable glucose sensors in vivo was developed. Our study showed that the delivery of an anti-inflammatory agent with the presentation of micro-sized topographical cues from coatings may lead to improved long-term glucose sensor function in vivo. We believe that improved function of sensors treated with the novel coatings was a result of the observed decreases in inflammatory cell density and increases in vessel density of the tissue adjacent to the devices. Furthermore, extending the in vivo functionality of implantable glucose sensors may lead to greater adoption of these devices by diabetic patients. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Femoral stem incorporating a diamond cubic lattice structure: Design, manufacture and testing.
Jetté, Bruno; Brailovski, Vladimir; Dumas, Mathieu; Simoneau, Charles; Terriault, Patrick
2018-01-01
The current total hip prostheses with dense femoral stems are considerably stiffer than the host bones, which leads to such long-term complications as aseptic loosening, and eventually, the need for a revision. Consequently, the lifetime of the implantation does not match the lifetime expectation of young patients. A femoral stem design featuring a porous structure is proposed to lower its stiffness and allow bone tissue ingrowth. The porous structure is based on a diamond cubic lattice in which the pore size and the strut thickness are selected to meet the biomechanical requirements of the strength and the bone ingrowth. A porous stem and its fully dense counterpart are produced by laser powder-bed fusion using Ti-6Al-4V alloy. To evaluate the stiffness reduction, static testing based on the ISO standard 7206-4 is performed. The experimental results recorded by digital image correlation are analyzed and compared to the numerical model. The numerical and experimental force-displacement characteristics of the porous stem show a 31% lower stiffness as compared to that of its dense counterpart. Moreover, the correlation analysis of the total displacement and equivalent strain fields allows the preliminary validation of the numerical model of the porous stem. Finally, the analysis of the surface-to-volume and the strength-to-stiffness ratios of diamond lattice structures allow the assessment of their potential as biomimetic constructs for load-bearing orthopaedic implants. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cehreli, Murat Cavit; Uysal, Serdar; Akca, Kivanc
2010-06-01
Documentation of early loading of mandibular overdentures supported by different implant systems is scarce. This study aimed to compare the biologic and prosthetic outcome of mandibular overdentures supported by unsplinted early-loaded one- and two-stage oral implants after 5 years of function. Twenty-eight consecutive patients were screened following an inclusion and exclusion criteria, and randomly allocated to treatment groups. Ball-retained mandibular overdentures were fabricated on two unsplinted Straumann (Institut Straumann AG, Basel, Switzerland) and Brånemark (Nobel Biocare AB, Göteborg, Sweden) dental implants and subjected to an early-loading protocol. During the 5-year period, prosthetic complications were recorded. At 5-years of function, plaque, peri-implant inflammation, bleeding, and calculus index scores were recorded, and standard periapical radiographs were obtained from each implant for measurement of marginal bone loss. All implants survived during the observation period. The peri-implant inflammation, bleeding, and calculus index scores around Straumann and Brånemark implants were similar (p > .05). The marginal bone loss around Brånemark implants (1.21 +/- 0.1) was higher than Straumann implants (0.73 +/- 0.06) at 5 years of function (p = .002). Kaplan-Meier tests revealed that 1- and 5-year survival of overdentures on Straumann and Brånemark implants were similar (p = .85). Wear of the ball abutment in the Brånemark group was higher than in the Straumann group (p < .05). Complications regarding the retainer and the need for occlusal adjustments were higher in the Straumann group (p < .05). Chi-square test revealed that the frequency of retightening of the retainer was higher in the Straumann group than in the Brånemark group (p < .05). Mandibular overdentures supported by unsplinted early-loaded Straumann and Brånemark implants lead to similar peri-implant soft tissue and prosthetic outcomes, although higher marginal bone loss could be observed around Brånemark implants after 5 years.
Oshima, Masamitsu; Inoue, Kaoru; Nakajima, Kei; Tachikawa, Tetsuhiko; Yamazaki, Hiromichi; Isobe, Tomohide; Sugawara, Ayaka; Ogawa, Miho; Tanaka, Chie; Saito, Masahiro; Kasugai, Shohei; Takano-Yamamoto, Teruko; Inoue, Takashi; Tezuka, Katsunari; Kuboki, Takuo; Yamaguchi, Akira; Tsuji, Takashi
2014-01-01
Bio-hybrid artificial organs are an attractive concept to restore organ function through precise biological cooperation with surrounding tissues in vivo. However, in bio-hybrid artificial organs, an artificial organ with fibrous connective tissues, including muscles, tendons and ligaments, has not been developed. Here, we have enveloped with embryonic dental follicle tissue around a HA-coated dental implant, and transplanted into the lower first molar region of a murine tooth-loss model. We successfully developed a novel fibrous connected tooth implant using a HA-coated dental implant and dental follicle stem cells as a bio-hybrid organ. This bio-hybrid implant restored physiological functions, including bone remodelling, regeneration of severe bone-defect and responsiveness to noxious stimuli, through regeneration with periodontal tissues, such as periodontal ligament and cementum. Thus, this study represents the potential for a next-generation bio-hybrid implant for tooth loss as a future bio-hybrid artificial organ replacement therapy. PMID:25116435
NASA Astrophysics Data System (ADS)
Makhov, D. V.; Lewis, Laurent J.
2005-05-01
The positron lifetimes for various vacancy clusters in silicon are calculated within the framework of the two-component electron-positron density functional theory. The effect of the trapped positron on the electron density and on the relaxation of the structure is investigated. Our calculations show that, contrary to the usual assumption, the positron-induced forces do not compensate in general for electronic inward forces. Thus, geometry optimization is required in order to determine positron lifetime accurately. For the monovacancy and the divacancy, the results of our calculations are in good agreement with the experimental positron lifetimes, suggesting that this approach gives good estimates of positron lifetimes for larger vacancy clusters, required for their correct identification with positron annihilation spectroscopy. As an application, our calculations show that fourfold trivacancies and symmetric fourfold tetravacancies have positron lifetimes similar to monovacancies and divacancies, respectively, and can thus be confused in the interpretation of positron annihilation experiments.
Nanotechnology for dental implants.
Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo
2013-01-01
With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.
Zou, Duohong; Wang, Feng; Wu, Yiqun; Huang, Wei; Zhang, Chenping; Zhang, Zhiyuan
2015-01-01
To evaluate the performance of dental implant-supported telescopic crown (TC)-retained overdentures to restore the oral function of patients who have insufficient jawbone volume resulting from tumor resection or trauma. From January 2004 to December 2008, implant-supported TC-retained overdentures were used to restore the oral function of patients with severe bony defects resulting from tumor resection or trauma. Clinical data, including implant success and survival rates, biologic and mechanical complications, prosthodontic maintenance efforts, and patient satisfaction, were analyzed annually after delivery of the final prostheses. Twenty-four patients were treated, and a total of 88 implants were inserted to support TC-retained overdentures. The mean modified plaque index of implants remained low (<20%), and the majority of implants (>76.3%) in the study showed the absence of bleeding on probing at follow-up visits. Peri-implant marginal bone loss (MBL) ranged from 0.8 to 1.2 mm. There was no statistically significant difference in the MBL between maxillary and mandibular implants (P = .43). The implant success rate was 100% after 5 years, and the prosthodontic maintenance and complication rate was 0.22 times per year. More than 90% of patients were satisfied with the restoration of their oral function using TCs. Based on our study of 24 patients treated with TC-retained overdentures, it appears that this treatment may be a viable option for patients with insufficient jawbone volume.
Luo, Xin; Fu, Qian-Jie; Galvin, John J.
2007-01-01
The present study investigated the ability of normal-hearing listeners and cochlear implant users to recognize vocal emotions. Sentences were produced by 1 male and 1 female talker according to 5 target emotions: angry, anxious, happy, sad, and neutral. Overall amplitude differences between the stimuli were either preserved or normalized. In experiment 1, vocal emotion recognition was measured in normal-hearing and cochlear implant listeners; cochlear implant subjects were tested using their clinically assigned processors. When overall amplitude cues were preserved, normal-hearing listeners achieved near-perfect performance, whereas listeners with cochlear implant recognized less than half of the target emotions. Removing the overall amplitude cues significantly worsened mean normal-hearing and cochlear implant performance. In experiment 2, vocal emotion recognition was measured in listeners with cochlear implant as a function of the number of channels (from 1 to 8) and envelope filter cutoff frequency (50 vs 400 Hz) in experimental speech processors. In experiment 3, vocal emotion recognition was measured in normal-hearing listeners as a function of the number of channels (from 1 to 16) and envelope filter cutoff frequency (50 vs 500 Hz) in acoustic cochlear implant simulations. Results from experiments 2 and 3 showed that both cochlear implant and normal-hearing performance significantly improved as the number of channels or the envelope filter cutoff frequency was increased. The results suggest that spectral, temporal, and overall amplitude cues each contribute to vocal emotion recognition. The poorer cochlear implant performance is most likely attributable to the lack of salient pitch cues and the limited functional spectral resolution. PMID:18003871
Chang, Y-M; Pan, Y-H; Shen, Y-F; Chen, J-K; ALDeek, N F; Wei, F-C
2016-12-01
We have evaluated the survival of dental implants placed in vascularised fibular flap onlay grafts placed over marginal mandibulectomies and the effects on marginal bone loss of different types of soft tissue around implants under functional loading. From 2001-2009 we studied a total of 11 patients (1 woman and10 men), three of whom had had ameloblastoma and eight who had had squamous cell carcinomas resected. A total of 38 dental implants were placed either at the time of transfer of the vascularised fibular ostoseptocutaneous flaps (nine patients with 30 implants) or secondarily (two patients with eight implants). Four patients were given palatal mucosal grafts to replace intraoral skin flaps around the dental implants (n=13), and the other seven had the skin flaps around the dental implants thinned (n=25) at the second stage of implantation of the osteointegrated teeth. All vascularised fibular osteoseptocutaneous flaps were successfully transferred, and all implants survived a mean (range) of 73 (33-113) months after occlusal functional loading. The mean (SD) marginal bone loss was 0.5 (0.3) mm on both mesial and distal sides in patients who had palatal mucosal grafts, but 1.8 (1.6) mm, and 1.7 (1.5) mm, respectively, on the mesial and distal sides in the patients who had had thinning of their skin flaps. This difference is significant (p=0.008) with less resorption of bone in the group who had palatal mucosal grafts. Palatal mucosa around the implants helps to reduce resorption of bone after functional loading of implants. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Shor, Erez; Shoham, Shy; Levenberg, Shulamit
2016-03-01
Spinal cord injury is a devastating medical condition. Recent developments in pre-clinical and clinical research have started to yield neural implants inducing functional recovery after spinal cord transection injury. However, the functional performance of the transplants was assessed using histology and behavioral experiments which are unable to study cell dynamics and the therapeutic response. Here, we use neurophotonic tools and optogenetic probes to investigate cellular level morphology and activity characteristics of neural implants over time at the cellular level. These methods were used in-vitro and in-vivo, in a mouse spinal cord injury implant model. Following previous attempts to induce recovery after spinal cord injury, we engineered a pre-vascularized implant to obtain better functional performance. To image network activity of a construct implanted in a mouse spinal cord, we transfected the implant to express GCaMP6 calcium activity indicators and implanted these constructs under a spinal cord chamber enabling 2-photon chronic in vivo neural activity imaging. Activity and morphology analysis image processing software was developed to automatically quantify the behavior of the neural and vascular networks. Our experimental results and analyses demonstrate that vascularized and non-vascularized constructs exhibit very different morphologic and activity patterns at the cellular level. This work enables further optimization of neural implants and also provides valuable tools for continuous cellular level monitoring and evaluation of transplants designed for various neurodegenerative disease models.
Dehennis, Andrew; Mortellaro, Mark A; Ioacara, Sorin
2015-07-29
Continuous glucose monitoring (CGM), which enables real-time glucose display and trend information as well as real-time alarms, can improve glycemic control and quality of life in patients with diabetes mellitus. Previous reports have described strategies to extend the useable lifetime of a single sensor from 1-2 weeks to 28 days. The present multisite study describes the characterization of a sensing platform achieving 90 days of continuous use for a single, fully implanted sensor. The Senseonics CGM system is composed of a long-term implantable glucose sensor and a wearable smart transmitter. Study subjects underwent subcutaneous implantation of sensors in the upper arm. Eight-hour clinic sessions were performed every 14 days, during which sensor glucose values were compared against venous blood lab reference measurements collected every 15 minutes using mean absolute relative differences (MARDs). All subjects (mean ± standard deviation age: 43.5 ± 11.0 years; with 10 sensors inserted in men and 14 in women) had type 1 diabetes mellitus. Most (22 of 24) sensors reported glucose values for the entire 90 days. The MARD value was 11.4 ± 2.7% (range, 8.1-19.5%) for reference glucose values between 40-400 mg/dl. There was no significant difference in MARD throughout the 90-day study (P = .31). No serious adverse events were noted. The Senseonics CGM, composed of an implantable sensor, external smart transmitter, and smartphone app, is the first system that uses a single sensor for continuous display of accurate glucose values for 3 months. © 2015 Diabetes Technology Society.
Dental-Implantate und ihre Werkstoffe
NASA Astrophysics Data System (ADS)
Newesely, Heinrich
1983-07-01
Some new trends in materials for dental implants, which also effect in the operative techniques and implant design, are described. Advantages and shortcomings of the different material types are exemplified and correlated with their bioinert resp. bioactive functions. The practical interest in metallic implants focussed in titanium resp. oxide ceramics in the ceramic field, whereas the special goal of implant research follows from the improvement of the bioactive principle with loaded calcium phosphate implants.
Gelb, David; McAllister, Bradley; Nummikoski, Pirkka; Del Fabbro, Massimo
2013-01-01
The aim of this study was to evaluate the clinical and radiographic long-term outcomes of dental implants with an anodized TiUnite surface, placed in routine clinical practice. Two clinical centers participated in the study. One hundred and seven implants (80 in the maxilla and 27 in the mandible) in 52 patients were followed in the long term. Both one- and two-stage techniques were used for 38 and 69 implants, respectively. Thirty-eight single tooth restorations and 22 fixed partial prostheses were delivered, according to a delayed loading protocol, within 4 to 12 months since implant placement. All implants were stable at insertion and at the long-term follow-up visit, which occurred between 7 and 8 years of functional loading. The mean followup was 7.33 ± 0.47 years. The mean marginal bone level change at the long-term followup as compared to baseline was 1.49 ± 1.03 mm. No implant failure occurred. Healthy peri-implant mucosa was found around 95% of implants, whereas 91% of implants showed no visible plaque at the implant surfaces at the long-term followup. The study showed that dental implants with the TiUnite anodized surface demonstrate excellent long-term clinical and radiographic outcomes. PMID:23533412
Salaria, Sanjeev Kumar; Sharma, Isha; Brar, Navjot Kaur; Kaur, Satwant
2018-01-01
Dental implant is being considered successful if the patient is pleased with both of its functional and esthetic outcome. As implant complications (such as peri-implantitis, inappropriate implant position, wrong angulation, and implant location too close to anatomical structures) have been frequently encountered in dental practice, therefore, thorough knowledge to manage such complications is the key prerequisite to prevent the failure of implant. The present case report discussed the etiology, diagnosis of early peri-implantitis, and periodontal abscess with their successful management through periodontal regeneration and diode laser-assisted therapy.
Lifetime achievement patterns, retirement and life satisfaction of gifted aged women.
Holahan, C K
1981-11-01
The relationship of lifetime achievement patterns and retirement to life satisfaction for gifted aging women was investigated. Participants were 352 women in Terman's study of the gifted who were surveyed in 1977 at a mean age of 66. Lifetime achievement pattern was defined by either homemaker, job, or career work history. Dependent variables included health, happiness, life satisfaction, work attitudes, ambitions and aspirations, and participation in leisure activities. Results showed variations on life satisfaction measures as a function of lifetime career, with job holders generally less satisfied. There was a significant interaction between marital status and work pattern on overall life satisfaction suggesting an additive negative effect on the older woman of loss of spouse and a work history of working for income alone. Activity involvement varied as a function of retirement status and was differentially related to life satisfaction as a function of retirement status and career pattern.
NASA Astrophysics Data System (ADS)
Ono, Junichi; Takada, Shoji; Saito, Shinji
2015-06-01
An analytical method based on a three-time correlation function and the corresponding two-dimensional (2D) lifetime spectrum is developed to elucidate the time-dependent couplings between the multi-timescale (i.e., hierarchical) conformational dynamics in heterogeneous systems such as proteins. In analogy with 2D NMR, IR, electronic, and fluorescence spectroscopies, the waiting-time dependence of the off-diagonal peaks in the 2D lifetime spectra can provide a quantitative description of the dynamical correlations between the conformational motions with different lifetimes. The present method is applied to intrinsic conformational changes of substrate-free adenylate kinase (AKE) using long-time coarse-grained molecular dynamics simulations. It is found that the hierarchical conformational dynamics arise from the intra-domain structural transitions among conformational substates of AKE by analyzing the one-time correlation functions and one-dimensional lifetime spectra for the donor-acceptor distances corresponding to single-molecule Förster resonance energy transfer experiments with the use of the principal component analysis. In addition, the complicated waiting-time dependence of the off-diagonal peaks in the 2D lifetime spectra for the donor-acceptor distances is attributed to the fact that the time evolution of the couplings between the conformational dynamics depends upon both the spatial and temporal characters of the system. The present method is expected to shed light on the biological relationship among the structure, dynamics, and function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ono, Junichi; Takada, Shoji; Department of Biophysics, Graduate School of Science, Kyoto University, Kyoto 606-8502
2015-06-07
An analytical method based on a three-time correlation function and the corresponding two-dimensional (2D) lifetime spectrum is developed to elucidate the time-dependent couplings between the multi-timescale (i.e., hierarchical) conformational dynamics in heterogeneous systems such as proteins. In analogy with 2D NMR, IR, electronic, and fluorescence spectroscopies, the waiting-time dependence of the off-diagonal peaks in the 2D lifetime spectra can provide a quantitative description of the dynamical correlations between the conformational motions with different lifetimes. The present method is applied to intrinsic conformational changes of substrate-free adenylate kinase (AKE) using long-time coarse-grained molecular dynamics simulations. It is found that the hierarchicalmore » conformational dynamics arise from the intra-domain structural transitions among conformational substates of AKE by analyzing the one-time correlation functions and one-dimensional lifetime spectra for the donor-acceptor distances corresponding to single-molecule Förster resonance energy transfer experiments with the use of the principal component analysis. In addition, the complicated waiting-time dependence of the off-diagonal peaks in the 2D lifetime spectra for the donor-acceptor distances is attributed to the fact that the time evolution of the couplings between the conformational dynamics depends upon both the spatial and temporal characters of the system. The present method is expected to shed light on the biological relationship among the structure, dynamics, and function.« less
Soft tissue sealing around dental implants based on histological interpretation.
Atsuta, Ikiru; Ayukawa, Yasunori; Kondo, Ryosuke; Oshiro, Wakana; Matsuura, Yuri; Furuhashi, Akihiro; Tsukiyama, Yoshihiro; Koyano, Kiyoshi
2016-01-01
The aim of this study was to provide an overview on the biology and soft tissue sealing around dental implants and teeth. This is a narrative review performed through scientific articles published between 1977 and 2014, indexed in MEDLINE and PubMed databases. The study selected articles that focused on epithelial sealing around dental implant or teeth with cell biology and histology of soft tissue. Implant therapy has been widely applied in dental rehabilitation for many years, with predictable long-term results. The longevity and functionality of dental implants is dependent on both osseointegration around the implant body and the establishment of a soft tissue barrier that protects the underlying hard tissue structures and the implant itself. The health and stability of the peri-implant mucosa also affects the esthetics of the implant. The healing and maintenance of the epithelial and connective tissues around implants are increasingly recognized as being fundamental to implant success. However, there has been little research into the function or formation of the soft tissue seal around dental implants, and the roles of this unique mucosal interface remain unclear. This narrative review explores the extent of the current knowledge of soft tissue barriers around implants from both a basic and clinical perspective, and aims to consolidate this knowledge and highlight the most pertinent questions relating to this area of research. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.; Lalonde, Kaylah
2012-01-01
Purpose To evaluate the family environments of children with cochlear implants and to examine relationships between family environment and post-implant language development and executive function. Method Forty-five families of children with cochlear implants completed a self-report family environment questionnaire (FES) and an inventory of executive function (BRIEF/BRIEF-P). Children’s receptive vocabulary (PPVT-4) and global language skills (PLS-4/CELF-4) were also evaluated. Results The family environments of children with cochlear implants differed from those of normal-hearing children, but not in clinically significant ways. Language development and executive function were found to be atypical, but not uncharacteristic of this clinical population. Families with higher levels of self-reported control had children with smaller vocabularies. Families reporting a higher emphasis on achievement had children with fewer executive function and working memory problems. Finally, families reporting a higher emphasis on organization had children with fewer problems related to inhibition. Conclusions Some of the variability in cochlear implantation outcomes that have protracted periods of development is related to family environment. Because family environment can be modified and enhanced by therapy or education, these preliminary findings hold promise for future work in helping families to create robust language-learning environments that can maximize their child’s potential with a cochlear implant. PMID:22232387
Immediate functional loading of single implants: a multicenter study with 4 years of follow-up
Raes, Filiep; Eccellente, Tammaro; Lenzi, Carolina; Ortolani, Michele; Luongo, Giuseppe; Mangano, Carlo; Mangano, Francesco
2018-01-01
Background. In the current scientific literature there are only few studies on the immediate functional loading of single implants. The aim of the present present study was to evaluate the 4-year survival rate, complication rate and peri-implant marginal bone loss (PIMBL) of immediately loaded single implants inserted in healed ridges and fresh post-extraction sites. Methods. Six centers were involved in this prospective study. The surgical and prosthetic protocol was defined in detail, before the start of recruiting patients. Recruitment of patients and performance of surgeries took place between February 2012 and February 2013. Criteria for inclusion were single-tooth gaps in healed ridges and fresh post-extraction sockets. All the fixtures (Anyridge®, Megagen Corporation, Gyeongbuk, South Korea) were functionally loaded immediately after insertion and followed for a period of 4 years. Outcome measures were implant survival, complications and PIMBL. Results. Forty-six patients (18‒73 years of age) were selected. In total, 57 fixtures were placed (10 in fresh post-extraction sockets). After 4 years of functional loading, only one fixture was lost; therefore, high survival rates (97.6% patient-based; 98.1% implant-based) were reported. In addition, a limited incidence of biologic (4.8% patient-based; 3.8% implant-based) and prosthetic (9.7% patient-based; 7.6% implant-based) complications was reported. The overall 4-year PIMBL amounted to 0.38±0.21 mm (healed ridges: 0.4±0.21 mm; fresh post-extraction sockets: 0.33±0.20 mm). Conclusion. Loading single implants immediately seems to be a highly successful treatment modality. However, long-term data are needed to confirm these positive outcomes. PMID:29732018
Surface characteristics of clinically used dental implant screws
NASA Astrophysics Data System (ADS)
Han, Myung-Ju; Choe, Han-Cheol; Chung, Chae-Heon
2005-12-01
Surface alteration of implant screws after function may be associated with mechanicalffailure. This type of metal fatigue appears to be the most common cause of structural failure. The purpose of this study was to evaluate surface alteration of implant screws after function through an examination of used and unused implant screws via scanning electron microscopy (SEM). In this study, abutment screws (Steri-oss, 3i, USA), gold retaining screws (3i, USA), and titanium retaining screws (3i, USA) were retrieved from patients, New, unused abutment, and retaining screws were prepared for a control group. Each of the old, used screws was retrieved with a screwdriver. The retrieved implant complex of a Steri-oss system was also prepared for this study. SEM investigation and energy dispersive spectroscopy (EDS) analysis of the abutment and retaining screws were then performed, as well as SEM investigation of a cross-sectioned sample of the retrieved implant complex in the case of new, unused implant screws, as-manufactured circumferential grooves were regularly examined and screw threads were sharply maintained. Before ultrasonic cleansing of old, used implant screws, there was a large amount of debris accumulation and corrosion products. After ultrasonic cleansing of old, used implant screws, circumferential grooves were examined were found to be randomly deepened and scratching increased. Also, dull screw fhreads were observed. More surface alterations after function were observed in titanium screws than in gold screws. Furthermore, more surface alteration was observed when the screws were retrieved with a driver than without a driver. These surface alterations after function may result in screw instability. Regular cleansing and exchange of screws is therefore recommended. We also recommend the use of gold screws over titanium screws, and careful manipulation of the driver.
Watzak, Georg; Zechner, Werner; Tangl, Stefan; Vasak, Christoph; Donath, Karl; Watzek, Georg
2006-04-01
The purpose of this study was to determine the peri-implant soft tissue dimension (PSD) and peri-implant bone level (BL) of dental implants with different designs and surface modifications after functional loading without oral hygiene. Three types of dental implants were placed in the posterior jaws of adult baboons, three of the same design per quadrant, and fitted with fixed partial dentures. After 1.5 years of functional loading and plaque accumulation, all implants showed severe peri-implant mucositis and comparatively high BL. A histomorphometric evaluation of the sulcus depth (SD), the dimension of the junctional epithelium (JE) and the connective tissue contact (CTC) resulted in no significant differences between the three implant designs, neither in the maxilla nor in the mandible (P>0.05). The sum of SD, JE and CTC forming the PSD was nearly the same in the maxilla (commercially pure titanium, CpTi: 3.5 mm 2.9/4.1 confidence interval (CI); titanium plasma sprayed (TPS): 3.5 mm 2.9/4.2 CI; sand blasted acid-etched (GBAE): 3.2 mm 2.7/3.9 CI) and in the mandible (CpTi: 3.2 mm 2.6/3.8 CI; TPS: 3.2 mm 2.6/3.8 CI; GBAE: 3.2 mm 2.7/3.9 CI; P>0.05). There was no difference in BL around the three implant designs (maxilla: CpTi: 0.9 mm 0.5/1.6 CI; TPS: 0.9 mm 0.5/1.5CI; GBAE: 0.9 mm 0.5/1.6 CI; mandible: CpTi: 0.8 mm 0.5/1.2 CI; TPS: 0.6 mm 0.4/0.9 CI; GBAE: 0.7 mm 0.5/1.1 CI; P>0.05). Overall, the data presented did not show any significant differences in peri-implant soft tissue conditions in baboons. Moreover, plaque accumulation and propagation of peri-implant mucositis after 1.5 years of functional loading was not influenced by implant design and surface modifications in baboons.
Pietrzak, Robert H.; Goldstein, Risë B.; Southwick, Steven M.; Grant, Bridget F.
2011-01-01
Background/Objectives Trauma exposure and posttraumatic stress disorder (PTSD) may increase risk for medical conditions in older adults. We present findings on past-year medical conditions associated with lifetime trauma exposure, and full and partial PTSD, in a nationally representative sample of U.S. older adults. Design, Setting, Participants, and Measurements Face-to-face diagnostic interviews were conducted with 9,463 adults aged 60 and older in the Wave 2 National Epidemiologic Survey on Alcohol and Related Conditions. Logistic regression analyses adjusting for sociodemographics and psychiatric comorbidity evaluated associations between PTSD status and past-year medical disorders; linear regression models evaluated associations with past-month physical functioning. Results After adjustment for sociodemographic characteristics and comorbid lifetime mood, anxiety, substance use, attention-deficit/hyperactivity, and personality disorders, respondents with lifetime PTSD were more likely than trauma controls to report being diagnosed by a healthcare professional with hypertension, angina pectoris, tachycardia, other heart disease, stomach ulcer, gastritis, and arthritis (odds ratios [ORs]=1.3–1.8); they also scored lower on a measure of physical functioning than controls and respondents with partial PTSD. Respondents with lifetime partial PTSD were more likely than controls to report past-year diagnoses of gastritis (OR=1.7), angina pectoris (OR=1.5), and arthritis (OR=1.4), and reported worse physical functioning. Number of lifetime traumatic event types was associated with most of the medical conditions assessed; adjustment for these events reduced the magnitudes of and rendered non-significant most associations between PTSD status and medical conditions. Conclusion Older adults with lifetime PTSD have elevated rates of several physical health conditions, many of which are chronic disorders of aging, and poorer physical functioning. Older adults with lifetime partial PTSD have elevated rates of gastritis, angina pectoris, and arthritis, and poorer physical functioning. PMID:22283516
An Implanted Upper-Extremity Neuroprosthesis Using Myoelectric Control
Kilgore, Kevin L.; Hoyen, Harry A.; Bryden, Anne M.; Hart, Ronald L.; Keith, Michael W.; Peckham, P. Hunter
2009-01-01
Purpose The purpose of this study was evaluate the potential of a second-generation implantable neuroprosthesis that provides improved control of hand grasp and elbow extension for individuals with cervical level spinal cord injury. The key feature of this system is that users control their stimulated function through electromyographic (EMG) signals. Methods The second-generation neuroprosthesis consists of 12 stimulating electrodes, 2 EMG signal recording electrodes, an implanted stimulator-telemeter device, an external control unit, and a transmit/receive coil. The system was implanted in a single surgical procedure. Functional outcomes for each subject were evaluated in the domains of body functions and structures, activity performance, and societal participation. Results Three individuals with C5/C6 spinal cord injury received system implantation with subsequent prospective evaluation for a minimum of 2 years. All 3 subjects demonstrated that EMG signals can be recorded from voluntary muscles in the presence of electrical stimulation of nearby muscles. Significantly increased pinch force and grasp function was achieved for each subject. Functional evaluation demonstrated improvement in at least 5 activities of daily living using the Activities of Daily Living Abilities Test. Each subject was able to use the device at home. There were no system failures. Two of 6 EMG electrodes required surgical revision because of suboptimal location of the recording electrodes. Conclusions These results indicate that a neuroprosthesis with implanted myoelectric control is an effective method for restoring hand function in midcervical level spinal cord injury. Type of study/level of evidence Therapeutic IV. PMID:18406958
Comparative Study of Intramedullary Hammertoe Fixation.
Obrador, Caterina; Losa-Iglesias, Marta; Becerro-de-Bengoa-Vallejo, Ricardo; Kabbash, Christina A
2018-04-01
Temporary Kirschner wire fixation (K-wire) is a widely used, low-cost fixation method for the correction of hammertoe deformity. Reported complications associated with K-wires prompted the development of new implants over the past decade. However, there is a lack of literature on comparative studies analyzing functional outcomes using validated questionnaires. The purpose of this study was to analyze functional outcomes in patients who had undergone proximal interphalangeal joint fusion using 2 types of intramedullary implant, the Smart Toe and the TenFuse, and to compare them with the outcomes in patients treated with standard K-wire fixation. A retrospective review of operative hammertoe correction by a single surgeon was performed in 96 patients followed for more than 12 months. Functional outcome was assessed using the Foot Function Index (FFI), the Short Form 36 (SF-36), and the 10-point visual analog scale (VAS) validated questionnaires. Complications and fusion rates were also evaluated. Several patients in the study underwent corrections in different toes; thus, a total of 186 toes were included in the study. From these, 65 toes (34.9%) were treated with K-wire fixation, 94 (50.5%) with Smart Toe titanium implant, and 27 (14.5%) with TenFuse allograft implant. No statistically significant differences in functional outcome and incidence of complications were observed among the 3 fixation groups, although the 2 intramedullary implants were associated with greater fusion rates and patient satisfaction. Breakage of the Smart Toe implant was significantly higher than that of the other fixations, with 10.6% of implants breaking within the first year postoperatively. SF-36 and VAS scores decreased 12 months after surgery for the 3 types of fixation, with no statistically significant differences observed. The use of Smart Toe and TenFuse implants provided operative outcomes comparable to those obtained using a K-wire fixation and slightly better patient satisfaction. Our results suggest that utilization of these implants for hammertoe correction was a reasonable choice that provided good alignment, pain reduction, and improved function at final follow-up. However, they are more expensive than K-wires. For this reason, in-depth cost-benefit studies would be required to justify their use as a standard treatment. Level III, comparative series.
NASA Technical Reports Server (NTRS)
Neudeck, Philip G.
1998-01-01
Minority carrier lifetimes in epitaxial 4H-SiC p-n junction diodes were measured via an analysis of reverse recovery switching characteristics. Behavior of reverse recovery storage time (t(sub s)) as a function of initial ON-state forward current (I(sub f)) and OFF-state reverse current (I(sub R)) followed well-documented trends which have been observed for decades in silicon p-n rectifiers. Average minority carrier (hole) lifetimes (tau(sub p)) calculated from plots of t(sub s) vs I(sub R)/I(sub F) strongly decreased with decreasing device area. Bulk and perimeter components of average hole lifetimes were separated by plotting tau(sub p) as a function of device perimeter-to-area ratio (P/A). This plot reveals that perimeter recombination is dominant in these devices, whose areas are all less than 1 square mm. The bulk minority carrier (hole) lifetime extracted from the 1/Tau(sub p) vs P/A plot is approximately 0.7 microns, well above the 60 ns to 300 ns average lifetimes obtained when perimeter recombination effects are ignored in the analysis. Given the fact that there has been little previous investigation of bipolar diode and transistor performance as a function of perimeter-to-area ratio, this work raises the possibility that perimeter recombination may be partly responsible for poor effective minority carrier lifetimes and limited performance obtained in many previous SiC bipolar junction devices.
NASA Astrophysics Data System (ADS)
Wlodarczyk, Jakub; Kierdaszuk, Borys
2005-08-01
Decays of tyrosine fluorescence in protein-ligand complexes are described by a model of continuous distribution of fluorescence lifetimes. Resulted analytical power-like decay function provides good fits to highly complex fluorescence kinetics. Moreover, this is a manifestation of so-called Tsallis q-exponential function, which is suitable for description of the systems with long-range interactions, memory effect, as well as with fluctuations of the characteristic lifetime of fluorescence. The proposed decay functions were applied to analysis of fluorescence decays of tyrosine in a protein, i.e. the enzyme purine nucleoside phosphorylase from E. coli (the product of the deoD gene), free in aqueous solution and in a complex with formycin A (an inhibitor) and orthophosphate (a co-substrate). The power-like function provides new information about enzyme-ligand complex formation based on the physically justified heterogeneity parameter directly related to the lifetime distribution. A measure of the heterogeneity parameter in the enzyme systems is provided by a variance of fluorescence lifetime distribution. The possible number of deactivation channels and excited state mean lifetime can be easily derived without a priori knowledge of the complexity of studied system. Moreover, proposed model is simpler then traditional multi-exponential one, and better describes heterogeneous nature of studied systems.
NASA Astrophysics Data System (ADS)
Żurek, Józef; Kaleta, Ryszard; Zieja, Mariusz
2016-06-01
The forecasting of reliability and life of aeronautical hardware requires recognition of many and various destructive processes that deteriorate the health/maintenance status thereof. The aging of technical components of aircraft as an armament system proves of outstanding significance to reliability and safety of the whole system. The aging process is usually induced by many and various factors, just to mention mechanical, biological, climatic, or chemical ones. The aging is an irreversible process and considerably affects (i.e. reduces) reliability and lifetime of aeronautical equipment. Application of the characteristic function of the aging process is suggested to predict reliability and lifetime of aeronautical hardware. An increment in values of diagnostic parameters is introduced to formulate then, using the characteristic function and after some rearrangements, the partial differential equation. An analytical dependence for the characteristic function of the aging process is a solution to this equation. With the inverse transformation applied, the density function of the aging of aeronautical hardware is found. Having found the density function, one can determine the aeronautical equipment's reliability and lifetime. The in-service collected or the life tests delivered data are used to attain this goal. Coefficients in this relationship are found using the likelihood function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Żurek, Józef; Kaleta, Ryszard; Zieja, Mariusz
2016-06-08
The forecasting of reliability and life of aeronautical hardware requires recognition of many and various destructive processes that deteriorate the health/maintenance status thereof. The aging of technical components of aircraft as an armament system proves of outstanding significance to reliability and safety of the whole system. The aging process is usually induced by many and various factors, just to mention mechanical, biological, climatic, or chemical ones. The aging is an irreversible process and considerably affects (i.e. reduces) reliability and lifetime of aeronautical equipment. Application of the characteristic function of the aging process is suggested to predict reliability and lifetime ofmore » aeronautical hardware. An increment in values of diagnostic parameters is introduced to formulate then, using the characteristic function and after some rearrangements, the partial differential equation. An analytical dependence for the characteristic function of the aging process is a solution to this equation. With the inverse transformation applied, the density function of the aging of aeronautical hardware is found. Having found the density function, one can determine the aeronautical equipment’s reliability and lifetime. The in-service collected or the life tests delivered data are used to attain this goal. Coefficients in this relationship are found using the likelihood function.« less
Nickenig, Hans-Joachim; Wichmann, Manfred; Schlegel, Karl Andreas; Nkenke, Emeka; Eitner, Stephan
2009-06-01
The purpose of this split-mouth study was to compare macro- and microstructure implant surfaces at the marginal bone level during a stress-free healing period and under functional loading. From January to February 2006, 133 implants (70 rough-surfaced microthreaded implants and 63 machined-neck implants) were inserted in the mandible of 34 patients with Kennedy Class I residual dentitions and followed until February 2008. The marginal bone level was radiographically determined, using digitized panoramic radiographs, at four time points: at implant placement (baseline level), after the healing period, after 6 months of functional loading, and at the end of follow-up. The median follow-up time was 1.9 (range: 1.9-2.1) years. The machined-neck group had a mean crestal bone loss of 0.5 mm (range: 0-2.3) after the healing period, 0.8 mm after 6 months (range: 0-2.4), and 1.1 mm (range: 0-3) at the end of follow-up. The rough-surfaced microthreaded implant group had a mean bone loss of 0.1 mm (range: -0.4-2) after the healing period, 0.4 mm (range: 0-2.1) after 6 months, and 0.5 mm (range: 0-2.1) at the end of follow-up. The two implant types showed significant differences in marginal bone levels (healing period: P=0.01; end of follow-up: P<0.01). Radiographic evaluation of marginal bone levels adjacent to machined-neck or rough-surfaced microthreaded implants showed that implants with the microthreaded design caused minimal changes in crestal bone levels during healing (stress-free) and under functional loading.
Positron Emission Tomography in Cochlear Implant and Auditory Brainstem Implant Recipients.
ERIC Educational Resources Information Center
Miyamoto, Richard T.; Wong, Donald
2001-01-01
Positron emission tomography imaging was used to evaluate the brain's response to auditory stimulation, including speech, in deaf adults (five with cochlear implants and one with an auditory brainstem implant). Functional speech processing was associated with activation in areas classically associated with speech processing. (Contains five…
Biological response on a titanium implant-grade surface functionalized with modular peptides☆
Yazici, H.; Fong, H.; Wilson, B.; Oren, E.E.; Amos, F.A.; Zhang, H.; Evans, J.S.; Snead, M.L.; Sarikaya, M.; Tamerler, C.
2015-01-01
Titanium (Ti) and its alloys are among the most successful implantable materials for dental and orthopedic applications. The combination of excellent mechanical and corrosion resistance properties makes them highly desirable as endosseous implants that can withstand a demanding biomechanical environment. Yet, the success of the implant depends on its osteointegration, which is modulated by the biological reactions occurring at the interface of the implant. A recent development for improving biological responses on the Ti-implant surface has been the realization that bifunctional peptides can impart material binding specificity not only because of their molecular recognition of the inorganic material surface, but also through their self-assembly and ease of biological conjugation properties. To assess peptide-based functionalization on bioactivity, the present authors generated a set of peptides for implant-grade Ti, using cell surface display methods. Out of 60 unique peptides selected by this method, two of the strongest titanium binding peptides, TiBP1 and TiBP2, were further characterized for molecular structure and adsorption properties. These two peptides demonstrated unique, but similar molecular conformations different from that of a weak binder peptide, TiBP60. Adsorption measurements on a Ti surface revealed that their disassociation constants were 15-fold less than TiBP60. Their flexible and modular use in biological surface functionalization were demonstrated by conjugating them with an integrin recognizing peptide motif, RGDS. The functionalization of the Ti surface by the selected peptides significantly enhanced the bioactivity of osteoblast and fibroblast cells on implant-grade materials. PMID:23159566
Lahens, Bradley; Neiva, Rodrigo; Tovar, Nick; Alifarag, Adham M; Jimbo, Ryo; Bonfante, Estevam A; Bowers, Michelle M; Cuppini, Marla; Freitas, Helora; Witek, Lukasz; Coelho, Paulo G
2016-10-01
A bone drilling concept, namely osseodensification, has been introduced for the placement of endosteal implants to increase primary stability through densification of the osteotomy walls. This study investigated the effect of osseodensification on the initial stability and early osseointegration of conical and parallel walled endosteal implants in low density bone. Five male sheep were used. Three implants were inserted in the ilium, bilaterally, totaling 30 implants (n=15 conical, and n=15 parallel). Each animal received 3 implants of each type, inserted into bone sites prepared as follows: (i) regular-drilling (R: 2mm pilot, 3.2mm, and 3.8mm twist drills), (ii) clockwise osseodensification (CW), and (iii) counterclockwise (CCW) osseodensification drilling with Densah Bur (Versah, Jackson, MI, USA): 2.0mm pilot, 2.8mm, and 3.8mm multi-fluted burs. Insertion torque as a function of implant type and drilling technique, revealed higher values for osseodensification relative to R-drilling, regardless of implant macrogeometry. A significantly higher bone-to-implant contact (BIC) for both osseodensification techniques (p<0.05) was observed compared to R-drilling. There was no statistical difference in BIC as a function of implant type (p=0.58), nor in bone-area-fraction occupancy (BAFO) as a function of drilling technique (p=0.22), but there were higher levels of BAFO for parallel than conic implants (p=0.001). Six weeks after surgery, new bone formation along with remodeling sites was observed for all groups. Bone chips in proximity with the implants were seldom observed in the R-drilling group, but commonly observed in the CW, and more frequently under the CCW osseodensification technique. In low-density bone, endosteal implants present higher insertion torque levels when placed in osseodensification drilling sites, with no osseointegration impairment compared to standard subtractive drilling methods. Copyright © 2016 Elsevier Ltd. All rights reserved.
Long-Term Implanted cOFM Probe Causes Minimal Tissue Reaction in the Brain
Hochmeister, Sonja; Asslaber, Martin; Kroath, Thomas; Pieber, Thomas R.; Sinner, Frank
2014-01-01
This study investigated the histological tissue reaction to long-term implanted cerebral open flow microperfusion (cOFM) probes in the frontal lobe of the rat brain. Most probe-based cerebral fluid sampling techniques are limited in application time due to the formation of a glial scar that hinders substance exchange between brain tissue and the probe. A glial scar not only functions as a diffusion barrier but also alters metabolism and signaling in extracellular brain fluid. cOFM is a recently developed probe-based technique to continuously sample extracellular brain fluid with an intact blood-brain barrier. After probe implantation, a 2 week healing period is needed for blood-brain barrier reestablishment. Therefore, cOFM probes need to stay in place and functional for at least 15 days after implantation to ensure functionality. Probe design and probe materials are optimized to evoke minimal tissue reaction even after a long implantation period. Qualitative and quantitative histological tissue analysis revealed no continuous glial scar formation around the cOFM probe 30 days after implantation and only a minor tissue reaction regardless of perfusion of the probe. PMID:24621608
NASA Astrophysics Data System (ADS)
Czan, Andrej; Babík, Ondrej; Miklos, Matej; Záušková, Lucia; Mezencevová, Viktória
2017-10-01
Since most of the implant surface is in direct contact with bone tissue, shape and integrity of said surface has great influence on successful osseointegration. Among other characteristics that predetermine titanium of different grades of pureness as ideal biomaterial, titanium shows high mechanical strength making precise miniature machining increasingly difficult. Current titanium-based implants are often anodized due to colour coding. This anodized layer has important functional properties for right usage and also bio-compatibility of dental implants. Physical method of anodizing and usage of anodizing mediums has a significant influence on the surface quality and itself functionality. However, basic requirement of the dental implant with satisfactory properties is quality of machined surface before anodizing. Roughness, for example, is factor affecting of time length of anodizing operation and so whole productivity. The paper is focused on monitoring of surface and area characteristics, such as roughness or surface integrity after different cutting conditions of miniature machining of dental implants and their impact on suitability for creation of satisfactory anodized layer with the correct biocompatible functional properties.
Maniewicz, Sabrina; Buser, Ramona; Duvernay, Elena; Vazquez, Lydia; Loup, Angelica; Perneger, Thomas V; Schimmel, Martin; Müller, Frauke
To describe the survival rate and peri-implant bone loss in very old patients dependent for their activities of daily living (ADL), treated with mandibular two-implant overdentures (IODs) in the context of a previously reported randomized controlled trial. A total of 19 patients received two interforaminal Straumann implants (Regular Neck, 4.1 mm diameter, 8 mm length) that were subsequently loaded with Locator attachments, transforming their preexisting inferior conventional denture into an IOD. The primary outcome measures were implant survival rate and radiographically assessed peri-implant bone loss. Secondary outcome measures included peri-implant probing depth and Plaque Index scores, as well as implant mobility. Nutritional state (body mass index and blood markers) and cognitive state (Mini-Mental State Examination) were also analyzed. The patient cohort comprised eight men and 11 women with a mean age of 85.7 ± 6.6 years. The implant survival rate up to 5 years was 94.7%, with one early and one late implant failure. The mean loss of peri-implant bone height was 0.17 mm per year (95% confidence interval: 0.09 to 0.24; P < .001). Peri-implant probing depth and Plaque Index scores were low and stable during the first 2 years, and thereafter increased continuously. Correlation analysis suggests that a reduced cognitive function and nutritional state are not a particular risk factor for accelerated peri-implant bone loss. The high implant survival and acceptable peri-implant health suggest that neither age nor dependency for the ADLs is a contraindication for the placement of implants. Nevertheless, close monitoring of the patients concerning a potential further functional decline precluding denture management and performing oral hygiene measures is advised.
Rich, Shanit; Levinger, Miriam; Werner, Shirli; Adelman, Cahtia
2013-08-01
The cochlear implant has revolutionized functioning with severe-to-profound sensori-neural loss. A deaf child implanted at an early age with good habilitation may have good language abilities and function well in daily life. As the implanted child grows up, managing in the world of hearing people may become more complex. During adolescence, the teenager copes with many issues, including identity, socialization with the peer group, and managing in the school setting. These issues may be even more challenging for the adolescents using a cochlear implant. This study was designed to shed light on how adolescents with cochlear implants experience coping with the issues mentioned. Twelve teenagers (14-18 years old), fairly similar to the entire adolescent implanted population at the center at which the study was conducted, participated in the study. They had been unilaterally or bilaterally implanted at differing ages. The participants filled out a questionnaire dealing with their functioning in the educational setting, their social preferences and functioning, and their identity as hearing or deaf. The results were analyzed using the principles of thematic analysis. At school, some reported better achievements than others but they all expressed some difficulty functioning in class mainly in situations involving several speakers. From a social point of view, some reported a preference for association with normal hearing peers, whereas others favored hard-of-hearing friends, and one had no preference. Of those who touched on the topic of self-identity, one referred to herself as deaf, eight defined themselves as hard-of-hearing, and two consider themselves hearing. From the responses of these teenagers, it is clear that adolescents with cochlear implants are a heterogeneous group. Parents and teachers should be aware that adolescents with implants, even when successful academically, may experience difficulties in the classroom setting. Most of the participants in this study learning in a mainstream setting, preferred social relationships with hearing peers (to hard of hearing/deaf). The responses of these adolescents with cochlear implants support the conjecture that they have both a hearing identity and a deaf identity, which may be expressed at varying intensities depending on the situation at the time. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Bringing Hearing to the Deaf--Cochlear Implants: a Technical and Personal Account
NASA Astrophysics Data System (ADS)
Shipsey, Ian
2006-04-01
Cochlear implants are the first device to successfully restore neural function. They have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. In this talk the physiology of natural hearing will be reviewed from the perspective of a physicist, and the function of cochlear implants will be described in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. The social implications of cochlear implantation and the future outlook for auditory prostheses will also be discussed.
Zygoma Implant-Supported Prosthetic Rehabilitation of a Patient After Bilateral Maxillectomy.
Celakil, Tamer; Ayvalioglu, Demet Cagil; Sancakli, Erkan; Atalay, Belir; Doganay, Ozge; Kayhan, Kivanc Bektas
2015-10-01
Maxillectomy defects may vary from localized to extensive soft and hard tissue loss. In addition to physical and psychologic damages, functional and aesthetic aspects must be restored. This clinical report describes the rehabilitation of a patient with a zygoma implant-supported obturator prosthesis caused by a subtotal bilateral maxillectomy due to a squamous oral cell carcinoma. Prosthetic rehabilitation of this patient was performed after zygoma implant surgery. A maxillary obturator prosthesis supported by 2 osseointegrated zygoma implants was fabricated. Despite limited mouth opening and anatomic deficiencies, the patient's aesthetic and functional demands were fulfilled.
Fugazzotto, P A; Kirsch, A; Ackermann, K L; Neuendorff, G
1999-01-01
Numerous problems have been reported following various therapies used to attach natural teeth to implants beneath a fixed prosthesis. This study documents the results of 843 consecutive patients treated with 1,206 natural tooth/implant-supported prostheses utilizing 3,096 screw-fixed attachments. After 3 to 14 years in function, only 9 intrusion problems were noted. All problems were associated with fractured or lost screws. This report demonstrates the efficacy of such a treatment approach when a natural tooth/implant-supported fixed prosthesis is contemplated.
Combined tooth-implant-supported telescopic prostheses in a midterm follow-up of > 2 years.
Joda, Tim
2013-01-01
The aim of this trial was to evaluate telescopic-retained prostheses on teeth and implants. Ten patients with a mean of 2.8 teeth received strategic implants to achieve triangular/quadrangular support. Survival and complication rates were estimated for telescopic abutments and prostheses. After a mean observation period of > 2 years, no abutment was lost and all prostheses were in function. Complication rates were low, and maintenance services were limited to minor interventions. Combined tooth-implant-retained telescopic prostheses improve prosthetic support and offer successful function over a midterm period in patients with a severely reduced dentition.
The Use of Implants to Improve Removable Partial Denture Function.
Pimentel, Marcele Jardim; Arréllaga, Juan Pablo; Bacchi, Ataís; Del Bel Cury, Altair A
2014-12-01
The oral rehabilitation with conventional removable partial dentures in Kennedy class I patients allows continuous bone resorption, dislodgment of the prosthesis during the mastication caused by the resilience of the mucosa, and rotation of the prosthesis. Thus, the associations of distal implants become an attractive modality of treatment for these patients. This case report presented an association of removable partial dentures, milled crowns and osseointegrated implants to rehabilitate a partial edentulous patient. A removable partial denture associated with implants and metal-ceramic milled crowns can offer excellent esthetics, and will improve function and biomechanics, at a reduced cost.
Sohn, Dong-Seok; Kim, Woo-Sung; Lee, Won-Hyuk; Jung, Heui-Seung; Shin, Im-Hee
2010-10-01
The aim of this retrospective study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of 9 years of functioning (mean: 55.8 months; range: 5-108 months). The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and 1 private dental clinic. A total of 122 sintered porous-surfaced implants--Endopore (Innova Life Sciences, Toronto, Ontario, Canada)--were placed in the edentulous posterior mandibles. Two diameter sizes (4.1 and 5.0 mm) and 4 lengths (5.0, 7.0, 9.0, and 12.0 mm) were used. All implants were restored with fixed prostheses. One hundred three implants were splinted and 21 implants were nonsplinted. Panoramic views and periapical radiographs were taken at the time of the first, postoperative, crown placement, and following checkup visits. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the χ² test. The survival rate of the 4.1-mm-diameter implants was 100% and 91.2% for the 5.0-mm-diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (P = 0.005). The survival rates of both the 5.0-mm and 7.0-mm-length implants were 100%. The survival rate of the 9.0-mm-length implants was 97.9% and for the 12.0-mm-length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the nonsplinted prostheses but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was <1.0. When the crown-to-implant ratio was between 1.0 and 1.4, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (P = 0.048). The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of 9 years of functioning in the edentulous posterior mandibles.
Bio-Functional Design, Application and Trends in Metallic Biomaterials
Yang, Ke; Zhou, Changchun; Fan, Hongsong; Fan, Yujiang; Jiang, Qing; Song, Ping; Fan, Hongyuan; Chen, Yu; Zhang, Xingdong
2017-01-01
Introduction of metals as biomaterials has been known for a long time. In the early development, sufficient strength and suitable mechanical properties were the main considerations for metal implants. With the development of new generations of biomaterials, the concepts of bioactive and biodegradable materials were proposed. Biological function design is very import for metal implants in biomedical applications. Three crucial design criteria are summarized for developing metal implants: (1) mechanical properties that mimic the host tissues; (2) sufficient bioactivities to form bio-bonding between implants and surrounding tissues; and (3) a degradation rate that matches tissue regeneration and biodegradability. This article reviews the development of metal implants and their applications in biomedical engineering. Development trends and future perspectives of metallic biomaterials are also discussed. PMID:29271916
Bio-Functional Design, Application and Trends in Metallic Biomaterials.
Yang, Ke; Zhou, Changchun; Fan, Hongsong; Fan, Yujiang; Jiang, Qing; Song, Ping; Fan, Hongyuan; Chen, Yu; Zhang, Xingdong
2017-12-22
Introduction of metals as biomaterials has been known for a long time. In the early development, sufficient strength and suitable mechanical properties were the main considerations for metal implants. With the development of new generations of biomaterials, the concepts of bioactive and biodegradable materials were proposed. Biological function design is very import for metal implants in biomedical applications. Three crucial design criteria are summarized for developing metal implants: (1) mechanical properties that mimic the host tissues; (2) sufficient bioactivities to form bio-bonding between implants and surrounding tissues; and (3) a degradation rate that matches tissue regeneration and biodegradability. This article reviews the development of metal implants and their applications in biomedical engineering. Development trends and future perspectives of metallic biomaterials are also discussed.
The power of sound: miniaturized medical implants with ultrasonic links
NASA Astrophysics Data System (ADS)
Wang, Max L.; Chang, Ting Chia; Charthad, Jayant; Weber, Marcus J.; Arbabian, Amin
2017-05-01
Miniaturized wirelessly powered implants capable of operating and communicating deep in the body are necessary for the next-generation of diagnostics and therapeutics. A major challenge in developing these minimally invasive implants is the tradeoff between device size, functionality, and operating depth. Here, we review two different wireless powering methods, inductive and ultrasonic power transfer, examine how to analyze their power transfer efficiency, and evaluate their potential for powering implantable medical devices. In particular, we show how ultrasonic wireless power transfer can address these challenges due to its safety, low attenuation, and millimeter wavelengths in the body. Finally, we demonstrate two ultrasonically powered implants capable of active power harvesting and bidirectional communication for closed-loop operation while functioning through multiple centimeters of tissue.
Ravald, Nils; Dahlgren, Simon; Teiwik, Anders; Gröndahl, Kerstin
2013-10-01
To study the long-term outcome of implant survival rate, soft and hard tissue conditions and prosthetic status in a group of individuals treated with either Astra Tech TiOblast or Brånemark turned implants supporting a full-arch bridge. Edentulous patients treated with either Astra Tech TiOblast surface or Brånemark turned implants were recalled for examination after 12-15 years. Out of initially 66 patients 46 were available for examination. Intra-oral radiographs were taken for bone level assessments. Clinical prosthetic conditions, number of surviving implants, implant stability, plaque scores, probing pocket depths, bleeding and pus after probing were recorded. Analyses of bone level changes during the total observation period were performed. Three patients in the Astra Tech group lost totally eight implants and five patients in the Brånemark group lost 10 implants during the total observation period. No statistically significant difference in implant loss or bone level change was found. Sixteen per cent of Astra Tech and 29% of Brånemark patients showed at least one implant with ≥2 mm bone loss after the first year in function. The corresponding prevalence on implant level was 6% and 5% respectively. No significant differences were found between the other examined variables. Two patients showed prosthetic complications of the supra construction in need of repair. Seven bridges had minor ceramic chippings. Treatment with Astra Tech TiOblast implants and Brånemark turned implants supporting full-arch bridges showed generally good clinical results with low numbers of implants with marginal bone loss indicative of peri-implantitis. No significant differences were found between the implant systems after 12-15 years in function. © 2012 John Wiley & Sons A/S.
A study on setting of the fatigue limit of temporary dental implants.
Kim, M H; Cho, E J; Lee, J W; Kim, E K; Yoo, S H; Park, C W
2017-07-01
A temporary dental implant is a medical device which is temporarily used to support a prosthesis such as an artificial tooth used for restoring patient's masticatory function during implant treatment. It is implanted in the oral cavity to substitute for the role of tooth. Due to the aging and westernization of current Korean society, the number of tooth extraction and implantation procedures is increasing, leading to an increase in the use and development of temporary dental implants. Because an implant performs a masticatory function in place of a tooth, a dynamic load is repeatedly put on the implant. Thus, the fatigue of implants is reported to be the most common causes of the fracture thereof. According to the investigation and analysis of the current domestic and international standards, the standard for fatigue of implant fixtures is not separately specified. Although a test method for measuring the fatigue is suggested in an ISO standard, it is a standard for permanent dental implants. Most of the test standards for Korean manufacturers and importers apply 250 N or more based on the guidance for the safety and performance evaluation of dental implants. Therefore, this study is intended to figure out the fatigue standard which can be applied to temporary dental implants when measuring the fatigue according to the test method suggested in the permanent dental implant standard. The results determined that suitable fatigue standards of temporary dental implants should be provided by each manufacturer rather than applying 250 N. This study will be useful for the establishment of the fatigue standards and fatigue test methods of the manufacturers and importers of temporary dental implants.
Zafiropoulos, Gregory-George; Hoffman, Oliver
2011-01-01
Dental implants as abutments for full-arch restorations are a well-documented treatment modality. This report presents a case in which the patient was treated initially with fixed restorations supported by either implants or natural teeth and subsequently treated with a removable implant/telescopic crown-supported overdenture. Advantages and disadvantages of each approach are described and discussed. While the fixed restoration resulted in a functionally satisfactory treatment outcome, the patient was displeased with the esthetic appearance. The main concern was the unnaturally long tooth shape necessary to compensate for the insufficient alveolar ridge height. Replacement of the existing restoration with an implant-supported removable overdenture led to a functionally and esthetically acceptable result. When deciding whether to use a fixed or removable implant-supported full-arch restoration, a multitude of factors must be considered. Due to the possible need for additional surgical steps to enhance the esthetic appearance surrounding fixed restorations, removable implant-supported partial dentures often are the better choice.
On stress/strain shielding and the material stiffness paradigm for dental implants.
Korabi, Raoof; Shemtov-Yona, Keren; Rittel, Daniel
2017-10-01
Stress shielding considerations suggest that the dental implant material's compliance should be matched to that of the host bone. However, this belief has not been confirmed from a general perspective, either clinically or numerically. To characterize the influence of the implant stiffness on its functionality using the failure envelope concept that examines all possible combinations of mechanical load and application angle for selected stress, strain and displacement-based bone failure criteria. Those criteria represent bone yielding, remodeling, and implant primary stability, respectively MATERIALS AND METHODS: We performed numerical simulations to generate failure envelopes for all possible loading configurations of dental implants, with stiffness ranging from very low (polymer) to extremely high, through that of bone, titanium, and ceramics. Irrespective of the failure criterion, stiffer implants allow for improved implant functionality. The latter reduces with increasing compliance, while the trabecular bone experiences higher strains, albeit of an overall small level. Micromotions remain quite small irrespective of the implant's stiffness. The current paradigm favoring reduced implant material's stiffness out of concern for stress or strain shielding, or even excessive micromotions, is not supported by the present calculations, that point exactly to the opposite. © 2017 Wiley Periodicals, Inc.
A long-lived tritiated titanium target for fast neutron production
NASA Astrophysics Data System (ADS)
Hughey, B. J.
1995-03-01
Diagnostic techniques using neutron beams have a broad spectrum of applications in advanced manufacturing, explosives and contraband detection, medicine, and industry. The most suitable nuclear reaction for producing large fluxes of fast neutrons at low bombarding energy is the H(d,n)-3 He-4, i.e. d-T, reaction. The lifetime of currently used d-T neutron generators is limited by the gradual evolution of tritium gas from the target during bombardment. This paper is a report of work in progress to develop a method for inhibiting the replacement of tritium with beam deuterons and thus preventing the evolution of tritium gas leading to reduced neutron yield. It is anticipated that tritiated target lifetime can be increased by at least an order of magnitude by using a range-thin tritiated titanium target mounted on a substrate with a high hydrogen diffusivity, such as niobium. Lifetime can be further enhanced by increasing the deuteron beam bombarding energy from the typical value of 200 keV to 600 keV. The results of experiments demonstrating the effect of hydrogen diffusion coefficient on concentration of implanted beam deuterons in candidate substrate materials (Cu, Pd, and Nb) are presented, and issues relevant to the fabrication of a tritiated titanium target on a niobium substrate are discussed.
Zhao, Meng-li; Liu, Xiao-qi; Cao, Ye; Li, Xi-fei; Li, De-jun; Sun, Xue-liang; Gu, Han-qing; Wan, Rong-xin
2016-01-01
Low hydrophilicity of graphene is one of the major obstacles for biomaterials application. To create some hydrophilic groups on graphene is addressed this issue. Herein, COOH+ ion implantation modified graphene (COOH+/graphene) and COOH functionalized graphene were designed by physical ion implantation and chemical methods, respectively. The structure and surface properties of COOH+/graphene and COOH functionalized graphene were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), and contact angle measurement. Compared with graphene, COOH+/graphene and COOH functionalized graphene revealed improvement of cytocompatibility, including in vitro cell viability and morphology. More importantly, COOH+/graphene exhibited better improvement effects than functionalized graphene. For instance, COOH+/graphene with 1 × 1018 ions/cm2 showed the best cell-viability, proliferation and stretching. This study demonstrated that ion implantation can better improve the cytocompatibility of the graphene. PMID:27845420
Waters, Allison M; Forrest, Kylee; Peters, Rosie-Mae; Bradley, Brendan P; Mogg, Karin
2015-03-01
Children of parents with emotional disorders have an increased risk for developing anxiety and depressive disorders. Yet the mechanisms that contribute to this increased risk are poorly understood. The present study aimed to examine attention biases in children as a function of maternal lifetime emotional disorders and maternal attention biases. There were 134 participants, including 38 high-risk children, and their mothers who had lifetime emotional disorders; and 29 low-risk children, and their mothers without lifetime emotional disorders. Mothers and children completed a visual probe task with emotional face pairs presented for 500 ms. Attention bias in children did not significantly differ solely as a function of whether or not their mothers had lifetime emotional disorders. However, attention bias in high-risk children was significantly related to their mothers' attention bias. Specifically, children of mothers with lifetime emotional disorders showed a greater negative attention bias if their mothers had a greater tendency to direct attention away from positive information. This study was cross-sectional in nature, and therefore unable to assess long-term predictive effects. Also, just one exposure duration of 500 ms was utilised. Attention bias for negative information is greater in offspring of mothers who have lifetime emotional disorders and a reduced positive bias, which could be a risk marker for the development of emotional disorders in children.
Auther, A M; McLaughlin, D; Carrión, R E; Nagachandran, P; Correll, C U; Cornblatt, B A
2012-12-01
Clinical and epidemiological studies suggest an association between cannabis use and psychosis but this relationship remains controversial. Clinical high-risk (CHR) subjects (age 12-22 years) with attenuated positive symptoms of psychosis (CHR+, n=101) were compared to healthy controls (HC, n=59) on rates of substance use, including cannabis. CHR+ subjects with and without lifetime cannabis use (and abuse) were compared on prodromal symptoms and social/role functioning at baseline. Participants were followed an average of 2.97 years to determine psychosis conversion status and functional outcome. At baseline, CHR+ subjects had significantly higher rates of lifetime cannabis use than HC. CHR+ lifetime cannabis users (n=35) were older (p=0.015, trend), more likely to be Caucasian (p=0.002), less socially anhedonic (p<0.001) and had higher Global Functioning: Social (GF:Social) scores (p<0.001) than non-users (n=61). CHR+ cannabis users continued to have higher social functioning than non-users at follow-up (p<0.001) but showed no differences in role functioning. A small sample of CHR+ cannabis abusers (n=10) showed similar results in that abusers were older (p=0.008), less socially anhedonic (p=0.017, trend) and had higher baseline GF:Social scores (p=0.006) than non-abusers. Logistic regression analyses revealed that conversion to psychosis in CHR+ subjects (n=15) was not related to lifetime cannabis use or abuse. The current data do not indicate that low to moderate lifetime cannabis use is a major contributor to psychosis or poor social and role functioning in clinical high-risk youth with attenuated positive symptoms of psychosis.
A contact mechanics model for ankle implants with inclusion of surface roughness effects
NASA Astrophysics Data System (ADS)
Hodaei, M.; Farhang, K.; Maani, N.
2014-02-01
Total ankle replacement is recognized as one of the best procedures to treat painful arthritic ankles. Even though this method can relieve patients from pain and reproduce the physiological functions of the ankle, an improper design can cause an excessive amount of metal debris due to wear, causing toxicity in implant recipient. This paper develops a contact model to treat the interaction of tibia and talus implants in an ankle joint. The contact model describes the interaction of implant rough surfaces including both elastic and plastic deformations. In the model, the tibia and the talus surfaces are viewed as macroscopically conforming cylinders or conforming multi-cylinders containing micrometre-scale roughness. The derived equations relate contact force on the implant and the minimum mean surface separation of the rough surfaces. The force is expressed as a statistical integral function of asperity heights over the possible region of interaction of the roughness of the tibia and the talus implant surfaces. A closed-form approximate equation relating contact force and minimum separation is used to obtain energy loss per cycle in a load-unload sequence applied to the implant. In this way implant surface statistics are related to energy loss in the implant that is responsible for internal void formation and subsequent wear and its harmful toxicity to the implant recipient.
Custom implant design for large cranial defects.
Marreiros, Filipe M M; Heuzé, Y; Verius, M; Unterhofer, C; Freysinger, W; Recheis, W
2016-12-01
The aim of this work was to introduce a computer-aided design (CAD) tool that enables the design of large skull defect (>100 [Formula: see text]) implants. Functional and aesthetically correct custom implants are extremely important for patients with large cranial defects. For these cases, preoperative fabrication of implants is recommended to avoid problems of donor site morbidity, sufficiency of donor material and quality. Finally, crafting the correct shape is a non-trivial task increasingly complicated by defect size. We present a CAD tool to design such implants for the neurocranium. A combination of geometric morphometrics and radial basis functions, namely thin-plate splines, allows semiautomatic implant generation. The method uses symmetry and the best fitting shape to estimate missing data directly within the radiologic volume data. In addition, this approach delivers correct implant fitting via a boundary fitting approach. This method generates a smooth implant surface, free of sharp edges that follows the main contours of the boundary, enabling accurate implant placement in the defect site intraoperatively. The present approach is evaluated and compared to existing methods. A mean error of 89.29 % (72.64-100 %) missing landmarks with an error less or equal to 1 mm was obtained. In conclusion, the results show that our CAD tool can generate patient-specific implants with high accuracy.
An implanted 8-channel array coil for high-resolution macaque MRI at 3T
Janssens, T.; Keil, B.; Farivar, R.; McNab, J.A.; Polimeni, J. R.; Gerits, A.; Arsenault, J.T.; Wald, L. L.; Vanduffel, W.
2012-01-01
An 8-channel receive coil array was constructed and implanted adjacent to the skull in a male rhesus monkey in order to improve the sensitivity of (functional) brain imaging. The permanent implant was part of an acrylic headpost assembly and only the coil element loop wires were implanted. The tuning, matching, and preamplifier circuitry was connected via a removable external assembly. Signal-to-noise ratio (SNR) and noise amplification for parallel imaging were compared to a single-, 4-, and 8-channel external receive-only coil routinely used for macaque fMRI. In vivo measurements showed significantly improved SNR within the brain for the implanted versus the external coils. Within a region-of-interest covering the cerebral cortex, we observed a 5.4-, 3.6-fold, and 3.4-fold increase in SNR compared to the external single-, 4-, and 8-channel coil, respectively. In the center of the brain, the implanted array maintained a 2.4×, 2.5×, and 2.1× higher SNR, respectively compared to the external coils. The array performance was evaluated for anatomical, diffusion tensor and functional brain imaging. This study suggests that a stable implanted phased-array coil can be used in macaque MRI to substantially increase the spatial resolution for anatomical, diffusion tensor, and functional imaging. PMID:22609793
Tan, Xiao Wei; Goh, Tze Wei; Saraswathi, P.; Nyein, Chan Lwin; Setiawan, Melina; Riau, Andri; Lakshminarayanan, R.; Liu, Shouping; Tan, Donald; Beuerman, Roger W.
2014-01-01
Titanium (Ti) is a promising candidate biomaterial for an artificial corneal skirt. Antimicrobial peptide (AMP) immobilization may improve the bactericidal effect of the Ti substrate. In this study, we tested the bactericidal efficacy of a functionalized Ti surface in a rabbit keratitis model. A corneal stromal pocket was created by a femtosecond laser. The Ti films were then inserted into the pocket, and Staphylococcus aureus or Pseudomonas aeruginosa was inoculated into the pocket above the implant films. The corneas with Ti-AMP implants were compared with the corneas implanted with unprotected Ti by slit lamp observation and anterior segment optical coherence tomography (AS-OCT). Inflammatory responses were evaluated by bacterium counting, hematoxylin-eosin staining, and immunostaining. There was a lower incidence and a lesser extent of infection on rabbit corneas with Ti-AMP implants than on those with unprotected Ti implants. The bactericidal effect of AMP against S. aureus was comparable to that of postoperative prophylactic antibiotic treatment; hence, SESB2V AMP bound to the Ti implant provided functional activity in vivo, but its efficacy was greater against S. aureus than against P. aeruginosa. This work suggests that SESB2V AMP can be successfully functionalized in a rabbit keratitis model to prevent perioperative corneal infection. PMID:24957820
Tsui, Hung-Chang; Chen, Chi-Hsien; Wu, Ying-Hsuan; Chiang, Hung-Che; Chen, Bing-Yu; Guo, Yue Leon
2018-05-01
Pulmonary function is known to be affected by acute and subacute exposure to ambient air pollution. However, the impacts of lifetime exposure to air pollution on the pulmonary function of children have been inconsistent. The present study investigated the impact of lifetime residential exposure to intermediate levels of air pollution on the pulmonary function of schoolchildren. In 2011, a survey of children aged 6-15 years was conducted in 44 schools in Taiwan. Atopic history, residential history, and environmental factors were recorded. Spirograms were obtained from a random sample of children without asthma. A total of 535 girls and 481 boys without a history of asthma were enrolled. Lifetime residential exposure to air pollutants, including particulate matter with an aerodynamic diameter less than 10 μm (PM 10 ), ozone (O 3 ), sulfur dioxide (SO 2 ), nitrogen dioxide (NO 2 ), and carbon monoxide (CO), was estimated using the kriging method, based on monitored data from the Taiwan Environmental Protection Administration. Multiple linear regression was used to analyze the association between lifetime air pollution exposure and pulmonary function, after adjustment for potential confounders and recent exposure. After adjustment for 7-day average air pollutant levels, a 10 μg/m 3 increase in PM 10 was related to reductions in the forced expiratory volume in 1 s (-2.00%; 95% confidence interval [CI] -3.09% to -0.90%), forced vital capacity (-1.86%; CI: -2.96% to -0.75%), and maximal midexpiratory flow (-2.28%; CI: -4.04% to -0.51%). These associations were independent of the other pollutants. Lifetime exposure to 25-85 μg/m 3 of PM 10 has negative impacts on the pulmonary function of children. Copyright © 2017 Elsevier Ltd. All rights reserved.
Borges Radaelli, Manuel Tomás; Idogava, Henrique Takashi; Spazzin, Aloisio Oro; Noritomi, Pedro Yoshito; Boscato, Noéli
2018-04-30
An occlusal device is frequently recommended for patients with bruxism to protect implant-supported restorations and prevent marginal bone loss. Scientific evidence to support this treatment is lacking. The purpose of this 3-dimensional (3D) finite element study was to evaluate the influence of an acrylic resin occlusal device, implant length, and insertion depth on stress distribution with functional and parafunctional loadings. Computer-aided design software was used to construct 8 models. The models were composed of a mandibular bone section including the second premolar and first and second molars. Insertion depths (bone level and 2 mm subcrestal) were simulated at the first molar. Three natural antagonist maxillary teeth and the placement or not of an occlusal device were simulated. Functional (200-N axial and 10-N oblique) and parafunctional (1000-N axial and 25-N oblique) forces were applied. Finite element analysis (FEA) was used to determine the maximum principal stress for the cortical and trabecular bone and von Mises for implant and prosthetic abutment. Stress concentration was observed at the abutment-implant and the implant-bone interfaces. Occlusal device placement changed the pattern of stress distribution and reduced stress levels from parafunctional loading in all structures, except in the trabecular bone. Implants with subcrestal insertion depths had reduced stress at the implant-abutment interface and cortical bone around the implant abutment, while the stress increased in the bone in contact with the implant. Parafunctional loading increased the stress levels in all structures when compared with functional loading. An occlusal device resulted in the lowest stress levels at the abutment and implant and the most favorable stress distribution between the cortical and trabecular bone. Under parafunctional loading, an occlusal device was more effective in reducing stress distribution for longer implants inserted at bone level. Subcrestally, implant insertion yielded the most favorable biomechanical conditions at the abutment-implant interface and at the coronal surface of the cortical bone, mainly when there was no occlusal device. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Renal Function Changes Following Left Ventricular Assist Device Implantation.
Daimee, Usama A; Wang, Meng; Papernov, Anna; Sherazi, Saadia; McNitt, Scott; Vidula, Himabindu; Chen, Leway; Alexis, Jeffrey D; Kutyifa, Valentina
2017-12-15
Limited data assessing the clinical significance of post-left ventricular assist device (LVAD) in renal function are available. We aimed to investigate the impact of changes in renal function after LVAD implantation on subsequent long-term outcomes. We followed 184 patients with HeartMate II LVADs implanted between May 2008 and November 2014. Serial assessment of renal function, was performed at baseline and at day 1, day 7, 1 month, 3 months, 6 months, 1 year, and 2 years after implantation. Effects of 1-month GFR and changes in GFR from baseline to 1 month on long-term mortality and hospital re-admission were evaluated. There were 30 patients with GFR <45 (low), 44 with GFR 45 to 59 (intermediate), and 110 with GFR ≥60 (normal) at baseline. Only patients with baseline GFR <45 experienced significant improvement in GFR after 2 years of follow-up (p = 0.012). At 1 month, a higher GFR category was significantly associated with a 31% reduction in mortality (hazard ratio [HR] 0.69, CI 0.49 to 0.98, p = 0.036), but not re-admission. Patients with baseline low and intermediate GFR who had no improvement in renal function category at 1 month experienced significantly greater risk of mortality (HR 1.95, CI 1.10 to 3.43, p = 0.022) and re-admission (HR 1.75, CI 1.07 to 2.84, p = 0.025), relative to patients whose GFR was normal at baseline and 1 month. In conclusion, renal function after LVAD implantation improves in patients with GFR <45. Change in renal function from baseline to 1 month after implantation is a powerful marker of long-term outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Fadli, A.; Akbar, F.; Prabowo, A.; Hidayah, P. H.
2018-04-01
Hydroxyapatite (HA) is a mineral form of naturally occurring apatite calcium with Ca10(PO4)6(OH)2 formula. One of the major innovations in the field of bone reconstruction is to apply HA as a surface coating on a mechanically strong implant metal and to improve the stability of bone implants thereby increasing the lifetime of the metal implants. Pure hydroxyapatite has poor mechanical properties so it is necessary to add sago starch as a binder to combine the strength and hardness of metal surfaces with bioactive properties of hydroxyapatite by Dip Coating method. Stainless steel 316L is the most commonly used alloy as an implant for bones and teeth due to its excellent corrosion and oxidation resistance and is easily formed. In this study, hydroxyapatite coatings used fixed variables as hydroxyapatite mass (10 grams), aquades mass (20 grams), dipping time (20 seconds), and calcination conditions (800°C, 1 hour). The variables are sago starch mass (1, 1.25, 1.5 gram) and stirring time (16, 20, 24 hours). The shear strength value is higher in the addition of 1.25, 10, 20, and again in the binder ratio of 1.5; 10; 20. The addition of stirring time causes a decrease in shear strength. The highest shear strength value obtained was 3.07 MPa. The layer attached to the substrate is a hydroxyapatite with a composition of 99.4% as evidenced by the results of XRD analysis.
Enhanced Magnetization of Cobalt Defect Clusters Embedded in TiO2-δ Films.
Cortie, David L; Khaydukov, Yury; Keller, Thomas; Sprouster, David J; Hughes, Jacob S; Sullivan, James P; Wang, Xiaolin L; Le Brun, Anton P; Bertinshaw, Joel; Callori, Sara J; Aughterson, Robert; James, Michael; Evans, Peter J; Triani, Gerry; Klose, Frank
2017-03-15
High magnetizations are desirable for spintronic devices that operate by manipulating electronic states using built-in magnetic fields. However, the magnetic moment in promising dilute magnetic oxide nanocomposites is very low, typically corresponding to only fractions of a Bohr magneton for each dopant atom. In this study, we report a large magnetization formed by ion implantation of Co into amorphous TiO 2-δ films, producing an inhomogeneous magnetic moment, with certain regions producing over 2.5 μ B per Co, depending on the local dopant concentration. Polarized neutron reflectometry was used to depth-profile the magnetization in the Co:TiO 2-δ nanocomposites, thus confirming the pivotal role of the cobalt dopant profile inside the titania layer. X-ray photoemission spectra demonstrate the dominant electronic state of the implanted species is Co 0 , with a minor fraction of Co 2+ . The detected magnetizations have seldom been reported before and lie near the upper limit set by Hund's rules for Co 0 , which is unusual because the transition metal's magnetic moment is usually reduced in a symmetric 3D crystal-field environment. Low-energy positron annihilation lifetime spectroscopy indicates that defect structures within the titania layer are strongly modified by the implanted Co. We propose that a clustering motif is promoted by the affinity of the positively charged implanted species to occupy microvoids native to the amorphous host. This provides a seed for subsequent doping and nucleation of nanoclusters within an unusual local environment.
Kerkhoffs, Wolfgang; Schumacher, Oliver; Meyns, Bart; Verbeken, Erik; Leunens, Veerle; Bollen, Hilde; Reul, Helmut
2004-10-01
The design concept and first in vitro and in vivo results of a long-term implantable ventricular assist device system based on a microaxial blood pump are presented. The blood-immersed parts of the pump consist of a single-stage impeller and a proximally integrated microelectric motor. Both parts are surrounded by a pump housing currently made of polycarbonate to allow visible access to the blood-exposed parts. A titanium inflow cage attached to the tip of the housing is directly implanted into the left ventricular apex. The outflow of the pump is connected to the descending aorta by means of an e-PTFE graft. The overall dimensions of the device are 12 mm in outer diameter and about 50 mm in length. The calculated lifetime of the device is up to 2 years. The system underwent long-term durability tests, hydraulic performance tests, dynamic stability tests, and in vitro hemolysis and thrombogenicity tests. Furthermore, animal tests have been performed in adult Dorset sheep. In a first series, the pump has been placed extracorporeally; in a second series, the pump was completely implanted. Mean duration of the animal experiments of the second series was 31 days (range 8-110 days, n=14); no anticoagulation was administered over the whole test period. Blood data revealed no significant changes in blood cell counts, ionogram, or any other value. No end-organ dysfunction induced by long-term support could be observed, nor did the pathology reveal any evidence of thromboembolic complications.
Friedl, Alexander; Bauer, Wilhelm; Rom, Maximilian; Kivaranovic, Danijel; Lüftenegger, Werner; Brössner, Clemens
2016-01-14
To investigate erectile function and sexuality before/after implantation of the ATOMS device including continence outcome, pain perception and co-morbidities. We collected data from 34 patients (2010-2014) who were provided with an ATOMS implant due to mild or moderate stress urinary incontinence (SUI) after radical prostatectomy (RPE), transurethral resection (TURP) or radiotherapy. Previous failed implants were no contraindication. Sexuality was evaluated with the International Index of Erectile Function (IIEF-5). The Visual Analog Scale (VAS) and Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) were used to analyse pain perception. Results regarding continence, influence of co-morbidities and drug intake were interpreted. IIEF-5 score increased 6 months after ATOMS implantation with a mean difference of 2.18 (Cl: 1.22, 3.14), p < 0,001). Non-sexually active patients had the greatest benefit. However, 50% of patients achieved a mean IIEF-5 of 10.1 and 38% of patients reported a new onset of sexual activity at follow up (mean IIEF-5 score of 12.9). This is in accordance with reduced SUI and absence of persistent pain syndrome. Overall success rate regarding 24h pad-use was 88% (no pad rate 38%). Previous failed implants did not influence results but diabetes, obesity and drug intake (beta-blockers, antidepressants) led to poorer outcomes. Sexuality and erectile function improves significantly 6 months after ATOMS implantation. We postulate that reduced SUI (also during sexual activity) and absence of chronic pain are the improving factors. ATOMS should be offered to men with mild to moderate SUI who are interested in regaining their erectile function and sexual activity.
Davis, Ross; Sparrow, Owen; Cosendai, Gregoire; Burridge, Jane H; Wulff, Christian; Turk, Ruth; Schulman, Joseph
2008-10-01
To investigate the feasibility of implanting microstimulators to deliver programmed nerve stimulation for sequenced muscle activation to recover arm-hand functions. By using a minimally invasive procedure and local anesthesia, 5 to 7 microstimulators can be safely and comfortably implanted adjacent to targeted radial nerve branches in the arm and forearm of 7 subjects with poststroke paresis. The microstimulators' position should remain stable with no tissue infection and can be programmed to produce effective personalized functional muscle activity with no discomfort for a preliminary 12-week study. Clinical testing, before and after the study, is reported in the accompanying study. Microstimulator implantations in a sterile operating room. Seven adults, with poststroke hemiparesis of 12 months or more. Under local anesthesia, a stimulating probe was inserted to identify radial nerve branches. Microstimulators were inserted by using an introducer and were retrievable for 6 days by attached suture. Each device was powered via a radiofrequency link from 2 external cuff coils connected to a control unit. To achieve low threshold values at the target sites with minimal implant discomfort. Microstimulators and external equipment were monitored over 12 weeks of exercise. Seven subjects were implanted with 41 microstimulators, 5 to 7 per subject, taking 3.5 to 6 hours. Implantation pain levels were 20% more than anticipated. No infections or microstimulator failures occurred. Mean nerve thresholds ranged between 4.0 to 7.7 microcoulomb/cm(2)/phase over 90 days, indicating that cathodes were within 2 to 4 mm of target sites. In 1 subject, 2 additional microstimulators were inserted. Microstimulators were safely implanted with no infection or failure. The system was reliable and programmed effectively to perform exercises at home for functional restoration.
Matveyenko, Aleksey V; Georgia, Senta; Bhushan, Anil; Butler, Peter C
2010-11-01
Embryonic stem cell therapy has been proposed as a therapeutic strategy to restore β-cell mass and function in T1DM. Recently, a group from Novocell (now ViaCyte) reported successful development of glucose-responsive islet-like structures after implantation of pancreatic endoderm (PE) derived from human embryonic stem cells (hESC) into immune-deficient mice. Our objective was to determine whether implantation of hESC-derived pancreatic endoderm from Novocell into athymic nude rats results in development of viable glucose-responsive pancreatic endocrine tissue. Athymic nude rats were implanted with PE derived from hESC either via implantation into the epididymal fat pads or by subcutaneous implantation into TheraCyte encapsulation devices for 20 wk. Blood glucose, weight, and human insulin/C-peptide secretion were monitored by weekly blood draws. Graft β-cell function was assessed by a glucose tolerance test, and graft morphology was assessed by immunohistochemistry and immunofluorescence. At 20 wk postimplantation, epididymal fat-implanted PE progressed to develop islet-like structures in 50% of implants, with a mean β-cell fractional area of 0.8 ± 0.3%. Human C-peptide and insulin were detectable, but at very low levels (C-peptide = 50 ± 26 pmol/l and insulin = 15 ± 7 pmol/l); however, there was no increase in human C-peptide/insulin levels after glucose challenge. There was no development of viable pancreatic tissue or meaningful secretory function when human PE was implanted in the TheraCyte encapsulation devices. These data confirm that islet-like structures develop from hESC differentiated to PE by the protocol developed by NovoCell. However, the extent of endocrine cell formation and secretory function is not yet sufficient to be clinically relevant.
Restoring Ovarian Endocrine Function with Encapsulated Ovarian Allograft in Immune Competent Mice
David, Anu; Day, James Ronald; Cichon, Alexa Leigh; Lefferts, Adam; Cascalho, Marilia; Shikanov, Ariella
2017-01-01
Premature ovarian insufficiency (POI) is a major complication of cytotoxic treatments due to extreme ovarian sensitivity to chemotherapy and radiation. In pediatric cancer patients modern therapy has improved the long-term survival to over 80% in the United States. However, these cancer survivors face long-term health problems related to treatment toxicity. In female cancer survivors POI leads to sterility, along with the consequences of estrogen deficiency such as premature osteopenia, muscle wasting, accelerated cardiovascular diseases and a vast array of other health and developmental problems. These long-lasting effects are particularly significant for young girls reaching puberty. As such, restoring ovarian endocrine function is paramount in this population. In the present study, we evaluated the feasibility of restoring ovarian endocrine function in ovariectomized mice by transplanting syngeneic and allogeneic ovarian tissue encapsulated in alginate capsules or TheraCyte®. Histological analysis of the implants retrieved after 7 and 30 days' post implantation showed follicular development up to the secondary and antral stages in both syngeneic and allogeneic implants. Implantation of syngeneic and allogeneic ovarian grafts encapsulated in TheraCyte devices restored ovarian endocrine function, which was confirmed by decreased serum FSH levels from 60 to 70 ng/mL in ovariectomized mice to 30–40 ng/mL 30 days after implantation. Absence of allo-MHC—specific IgG and IgM antibodies in the sera of implanted mice with allogeneic ovarian tissue encapsulated in TheraCyte indicate that the implants did not evoke an allo-immune response, while the allogeneic controls were rejected 21 days after implantation. Our results show that TheraCyte effectively isolates the graft from immune recognition but also supports follicular growth. PMID:28028710
Restoring Ovarian Endocrine Function with Encapsulated Ovarian Allograft in Immune Competent Mice.
David, Anu; Day, James Ronald; Cichon, Alexa Leigh; Lefferts, Adam; Cascalho, Marilia; Shikanov, Ariella
2017-07-01
Premature ovarian insufficiency (POI) is a major complication of cytotoxic treatments due to extreme ovarian sensitivity to chemotherapy and radiation. In pediatric cancer patients modern therapy has improved the long-term survival to over 80% in the United States. However, these cancer survivors face long-term health problems related to treatment toxicity. In female cancer survivors POI leads to sterility, along with the consequences of estrogen deficiency such as premature osteopenia, muscle wasting, accelerated cardiovascular diseases and a vast array of other health and developmental problems. These long-lasting effects are particularly significant for young girls reaching puberty. As such, restoring ovarian endocrine function is paramount in this population. In the present study, we evaluated the feasibility of restoring ovarian endocrine function in ovariectomized mice by transplanting syngeneic and allogeneic ovarian tissue encapsulated in alginate capsules or TheraCyte ® . Histological analysis of the implants retrieved after 7 and 30 days' post implantation showed follicular development up to the secondary and antral stages in both syngeneic and allogeneic implants. Implantation of syngeneic and allogeneic ovarian grafts encapsulated in TheraCyte devices restored ovarian endocrine function, which was confirmed by decreased serum FSH levels from 60 to 70 ng/mL in ovariectomized mice to 30-40 ng/mL 30 days after implantation. Absence of allo-MHC-specific IgG and IgM antibodies in the sera of implanted mice with allogeneic ovarian tissue encapsulated in TheraCyte indicate that the implants did not evoke an allo-immune response, while the allogeneic controls were rejected 21 days after implantation. Our results show that TheraCyte effectively isolates the graft from immune recognition but also supports follicular growth.
Matveyenko, Aleksey V.; Georgia, Senta; Bhushan, Anil
2010-01-01
Embryonic stem cell therapy has been proposed as a therapeutic strategy to restore β-cell mass and function in T1DM. Recently, a group from Novocell (now ViaCyte) reported successful development of glucose-responsive islet-like structures after implantation of pancreatic endoderm (PE) derived from human embryonic stem cells (hESC) into immune-deficient mice. Our objective was to determine whether implantation of hESC-derived pancreatic endoderm from Novocell into athymic nude rats results in development of viable glucose-responsive pancreatic endocrine tissue. Athymic nude rats were implanted with PE derived from hESC either via implantation into the epididymal fat pads or by subcutaneous implantation into TheraCyte encapsulation devices for 20 wk. Blood glucose, weight, and human insulin/C-peptide secretion were monitored by weekly blood draws. Graft β-cell function was assessed by a glucose tolerance test, and graft morphology was assessed by immunohistochemistry and immunofluorescence. At 20 wk postimplantation, epididymal fat-implanted PE progressed to develop islet-like structures in 50% of implants, with a mean β-cell fractional area of 0.8 ± 0.3%. Human C-peptide and insulin were detectable, but at very low levels (C-peptide = 50 ± 26 pmol/l and insulin = 15 ± 7 pmol/l); however, there was no increase in human C-peptide/insulin levels after glucose challenge. There was no development of viable pancreatic tissue or meaningful secretory function when human PE was implanted in the TheraCyte encapsulation devices. These data confirm that islet-like structures develop from hESC differentiated to PE by the protocol developed by NovoCell. However, the extent of endocrine cell formation and secretory function is not yet sufficient to be clinically relevant. PMID:20587750
Manzoor, Behzad; Suleiman, Mahmood; Palmer, Richard M
2013-01-01
The crestal bone level around a dental implant may influence its strength characteristics by offering protection against mechanical failures. Therefore, the present study investigated the effect of simulated bone loss on modes, loads, and cycles to failure in an in vitro model. Different amounts of bone loss were simulated: 0, 1.5, 3.0, and 4.5 mm from the implant head. Forty narrow-diameter (3.0-mm) implant-abutment assemblies were tested using compressive bending and cyclic fatigue testing. Weibull and accelerated life testing analysis were used to assess reliability and functional life. Statistical analyses were performed using the Fisher-Exact test and the Spearman ranked correlation. Compressive bending tests showed that the level of bone loss influenced the load-bearing capacity of implant-abutment assemblies. Fatigue testing showed that the modes, loads, and cycles to failure had a statistically significant relationship with the level of bone loss. All 16 samples with bone loss of 3.0 mm or more experienced horizontal implant body fractures. In contrast, 14 of 16 samples with 0 and 1.5 mm of bone loss showed abutment and screw fractures. Weibull and accelerated life testing analysis indicated a two-group distribution: the 0- and 1.5-mm bone loss samples had better functional life and reliability than the 3.0- and 4.5-mm samples. Progressive bone loss had a significant effect on modes, loads, and cycles to failure. In addition, bone loss influenced the functional life and reliability of the implant-abutment assemblies. Maintaining crestal bone levels is important in ensuring biomechanical sustainability and predictable long-term function of dental implant assemblies.
Coelho, Daniel H; Hammerschlag, Paul E; Bat-Chava, Yael; Kohan, Darius
2009-06-01
The Cochlear Implant Function Index (CIFI) is created to assess adult cochlear implant (CI) auditory effectiveness in real world situations. Our objective is to evaluate the CIFI as a reliable psychometric tool to assess 1) reliance on visual assistance, 2) telephone use, 3) communication at work, 4) 'hearing' in noise, 5) in groups, and 6) in large room settings. Based upon Guttman scaling properties, the CIFI elicits implanted respondent's functional level with auditory independence from Level 1 (still requiring signing) to level 4 (without any help beyond CI). A blinded, retrospective questionnaire is anonymously answered by cochlear implant recipients. CI centers of tertiary care medical centers, CI support group, and an interactive web page of a hearing and speech center in a large metropolitan region. 245 respondents from a varied adult CI population implanted for one month to 19 years prior to answering the questionnaire. An assessment tool of CI function. A coefficient of reproducibility (CR) for the Guttman scale format equal or greater than 0.90, indicating good scalability. CR in the CIFI was above 0.90. Effective scalability and mean scores from 2.5 to 3.5 for the six areas examined (1.00-4.00) were achieved. The psychometric properties of this user friendly survey demonstrate consistently good scalability. Based on these findings, the CIFI provides a validated tool that can be used for systematic comparisons between groups of patients or for follow-up outcomes in patients who use cochlear implants. Further study is indicated to correlate CIFI scores with sound and speech perception scores. Copyright 2009 John Wiley & Sons, Ltd.
Schröder, Tim; Trusheim, Matthew E.; Walsh, Michael; Li, Luozhou; Zheng, Jiabao; Schukraft, Marco; Sipahigil, Alp; Evans, Ruffin E.; Sukachev, Denis D.; Nguyen, Christian T.; Pacheco, Jose L.; Camacho, Ryan M.; Bielejec, Edward S.; Lukin, Mikhail D.; Englund, Dirk
2017-01-01
The controlled creation of defect centre—nanocavity systems is one of the outstanding challenges for efficiently interfacing spin quantum memories with photons for photon-based entanglement operations in a quantum network. Here we demonstrate direct, maskless creation of atom-like single silicon vacancy (SiV) centres in diamond nanostructures via focused ion beam implantation with ∼32 nm lateral precision and <50 nm positioning accuracy relative to a nanocavity. We determine the Si+ ion to SiV centre conversion yield to be ∼2.5% and observe a 10-fold conversion yield increase by additional electron irradiation. Low-temperature spectroscopy reveals inhomogeneously broadened ensemble emission linewidths of ∼51 GHz and close to lifetime-limited single-emitter transition linewidths down to 126±13 MHz corresponding to ∼1.4 times the natural linewidth. This method for the targeted generation of nearly transform-limited quantum emitters should facilitate the development of scalable solid-state quantum information processors. PMID:28548097
Schroder, Tim; Trusheim, Matthew E.; Walsh, Michael; ...
2017-05-26
The controlled creation of defect centre—nanocavity systems is one of the outstanding challenges for efficiently interfacing spin quantum memories with photons for photon-based entanglement operations in a quantum network. Here we demonstrate direct, maskless creation of atom-like single silicon vacancy (SiV) centres in diamond nanostructures via focused ion beam implantation with ~32 nm lateral precision and <50 nm positioning accuracy relative to a nanocavity. We determine the Si+ ion to SiV centre conversion yield to be ~2.5% and observe a 10-fold conversion yield increase by additional electron irradiation. Low-temperature spectroscopy reveals inhomogeneously broadened ensemble emission linewidths of ~51 GHz andmore » close to lifetime-limited single-emitter transition linewidths down to 126±13 MHz corresponding to ~1.4 times the natural linewidth. Furthermore, this method for the targeted generation of nearly transform-limited quantum emitters should facilitate the development of scalable solid-state quantum information processors.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schroder, Tim; Trusheim, Matthew E.; Walsh, Michael
The controlled creation of defect centre—nanocavity systems is one of the outstanding challenges for efficiently interfacing spin quantum memories with photons for photon-based entanglement operations in a quantum network. Here we demonstrate direct, maskless creation of atom-like single silicon vacancy (SiV) centres in diamond nanostructures via focused ion beam implantation with ~32 nm lateral precision and <50 nm positioning accuracy relative to a nanocavity. We determine the Si+ ion to SiV centre conversion yield to be ~2.5% and observe a 10-fold conversion yield increase by additional electron irradiation. Low-temperature spectroscopy reveals inhomogeneously broadened ensemble emission linewidths of ~51 GHz andmore » close to lifetime-limited single-emitter transition linewidths down to 126±13 MHz corresponding to ~1.4 times the natural linewidth. Furthermore, this method for the targeted generation of nearly transform-limited quantum emitters should facilitate the development of scalable solid-state quantum information processors.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deschamps, F., E-mail: frederic.deschamps@igr.fr; Elias, D., E-mail: elias@igr.fr; Goere, D., E-mail: goere@igr.fr
2011-10-15
Purpose: To compare retrospectively the safety and efficacy of percutaneous and surgical implantations of port-catheters for intra-arterial hepatic chemotherapy (IAHC). Materials and Methods: Between January 2004 and December 2008, 126 consecutive patients (mean age 58 years) suffering from liver colorectal metastases were referred for intra-arterial hepatic chemotherapy (IAHC). Port-catheters were percutaneously implanted (P) through femoral access with the patient under conscious sedation when no other surgery was planned or were surgically implanted (S) when laparotomy was performed for another purpose. We report the implantation success rate, primary functionality, functionality after revision, and complications of IAHC. Results: The success rates ofmore » implantation were 97% (n = 65 of 67) for P and 98% (n = 58 of 59) for S. One hundred eleven patients received IAHC in our institution (n = 56P and n = 55S). Primary functionality was the same for P and S (4.80 vs. 4.82 courses), but functionality after revision was significantly higher for P (9.18 vs. 5.95 courses, p = 0.004) than for S. Forty-five complications occurred during 516 courses for P and 28 complications occurred during 331 courses for S. The rates of discontinuation of IAHC linked to complications of the port-catheters were 21% (n = 12 of 56) for P and 34% (n = 19 of 55) for S. Conclusion: Overall, significantly better functionality and similar complication rates occurred after P versus S port-catheters.« less
Language and Psychosocial Functioning among Deaf Learners with and without Cochlear Implants
ERIC Educational Resources Information Center
Marschark, Marc; Machmer, Elizabeth; Spencer, Linda J.; Borgna, Georgianna; Durkin, Andreana; Convertino, Carol
2018-01-01
Various studies have examined psychosocial functioning and language abilities among deaf children with and without cochlear implants (CIs). Few, however, have explored how relations among those abilities might change with age and setting. Most relevant studies also have failed to consider that psychosocial functioning among both CI users and…
Thomas, Biju B; Zhu, Danhong; Zhang, Li; Thomas, Padmaja B; Hu, Yuntao; Nazari, Hossein; Stefanini, Francisco; Falabella, Paulo; Clegg, Dennis O; Hinton, David R; Humayun, Mark S
2016-05-01
To determine the safety, survival, and functionality of human embryonic stem cell-derived RPE (hESC-RPE) cells seeded on a polymeric substrate (rCPCB-RPE1 implant) and implanted into the subretinal (SR) space of Royal College of Surgeons (RCS) rats. Monolayers of hESC-RPE cells cultured on parylene membrane were transplanted into the SR space of 4-week-old RCS rats. Group 1 (n = 46) received vitronectin-coated parylene membrane without cells (rMSPM+VN), group 2 (n = 59) received rCPCB-RPE1 implants, and group 3 (n = 13) served as the control group. Animals that are selected based on optical coherence tomography screening were subjected to visual function assays using optokinetic (OKN) testing and superior colliculus (SC) electrophysiology. At approximately 25 weeks of age (21 weeks after surgery), the eyes were examined histologically for cell survival, phagocytosis, and local toxicity. Eighty-seven percent of the rCPCB-RPE1-implanted animals showed hESC-RPE survivability. Significant numbers of outer nuclear layer cells were rescued in both group 1 (rMSPM+VN) and group 2 (rCPCB-RPE1) animals. A significantly higher ratio of rod photoreceptor cells to cone photoreceptor cells was found in the rCPCB-RPE1-implanted group. Animals with rCPCB-RPE1 implant showed hESC-RPE cells containing rhodopsin-positive particles in immunohistochemistry, suggesting phagocytic function. Superior colliculus mapping data demonstrated that a significantly higher number of SC sites responded to light stimulus at a lower luminance threshold level in the rCPCB-RPE1-implanted group. Optokinetic data suggested both implantation groups showed improved visual acuity. These results demonstrate the safety, survival, and functionality of the hESC-RPE monolayer transplantation in an RPE dysfunction rat model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moon, Ho-Jin; Yun, Young-Pil; Han, Choong-Wan
2011-09-23
Highlights: {yields} We examine bone metabolism of engineered alendronate attached to Ti surfaces. {yields} Alendronate-immobilized Ti enhances activation of osteoblast differentiation. {yields} Alendronate-immobilized Ti inhibits osteoclast differentiation. {yields} Alendronate-immobilized Ti may be a bioactive implant with dual functions. -- Abstract: The failure of orthopedic and dental implants has been attributed mainly to loosening of the implant from host bone, which may be due to weak bonding of the implant material to bone tissue. Titanium (Ti) is used in the field of orthopedic and dental implants because of its excellent biocompatibility and outstanding mechanical properties. Therefore, in the field of materialsmore » science and tissue engineering, there has been extensive research to immobilize bioactive molecules on the surface of implant materials in order to provide the implants with improved adhesion to the host bone tissue. In this study, chemically active functional groups were introduced on the surface of Ti by a grafting reaction with heparin and then the Ti was functionalized by immobilizing alendronate onto the heparin-grafted surface. In the MC3T3-E1 cell osteogenic differentiation study, the alendronate-immobilized Ti substrates significantly enhanced alkaline phosphatase activity (ALP) and calcium content. Additionally, nuclear factor kappa B ligand (RANKL)-induced osteoclast differentiation of RAW264.7 cells was inhibited with the alendronate-immobilized Ti as confirmed by TRAP analysis. Real time PCR analysis showed that mRNA expressions of osteocalcin and osteopontin, which are markers for osteogenesis, were upregulated in MC3T3-E1 cells cultured on alendronate-immobilized Ti. The mRNA expressions of TRAP and Cathepsin K, markers for osteoclastogenesis, in RAW264.7 cells cultured on alendronate-immobilized Ti were down-regulated. Our study suggests that alendronate-immobilized Ti may be a bioactive implant with dual functions to enhance osteoblast differentiation and to inhibit osteoclast differentiation simultaneously.« less
Dynamic quadrupole interactions in semiconductors
NASA Astrophysics Data System (ADS)
Dang, Thien Thanh; Schell, Juliana; Lupascu, Doru C.; Vianden, Reiner
2018-04-01
The time differential perturbed angular correlation, TDPAC, technique has been used for several decades to study electric quadrupole hyperfine interactions in semiconductors such as dynamic quadrupole interactions (DQI) resulting from after-effects of the nuclear decay as well as static quadrupole interactions originating from static defects around the probe nuclei such as interstitial ions, stresses in the crystalline structure, and impurities. Nowadays, the quality of the available semiconductor materials is much better, allowing us to study purely dynamic interactions. We present TDPAC measurements on pure Si, Ge, GaAs, and InP as a function of temperature between 12 K and 110 K. The probe 111In (111Cd) was used. Implantation damage was recovered by thermal annealing. Si experienced the strongest DQI with lifetime, τg, increasing with rising temperature, followed by Ge. In contrast, InP and GaAs, which have larger band gaps and less electron concentration than Si and Ge in the same temperature range, presented no DQI. The results obtained also allow us to conclude that indirect band gap semiconductors showed the dynamic interaction, whereas the direct band gap semiconductors, restricted to GaAs and InP, did not.
Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H
2017-05-03
Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model determined that, compared with conventional bearings, DM implants can be cost-saving for routine primary total hip arthroplasty, from the societal perspective, if newer-generation DM implants meet specific economic and clinical benchmarks. The differences between these thresholds and the performance of other contemporary bearings were frequently quite narrow. The results have potential application to the postmarket surveillance of newer-generation DM components. Economic and decision analysis Level III. See Instructions for Authors for a complete description of levels of evidence.
Butler, Michael W; Leppert, Lynda L; Dufty, Alfred M
2010-01-01
Stressors encountered during avian development may affect an individual's phenotype, including immunocompetence, growth, and feather quality. We examined effects of simulated chronic low-level stress on American kestrel (Falco sparverius) nestlings. Continuous release of corticosterone, a hormone involved in the stress response, can model chronic stress in birds. We implanted 13-d-old males with either corticosterone-filled implants or shams and measured their growth, immune function, and feather coloration. We found no significant differences between groups at the end of the weeklong exposure period in morphometrics (mass, tarsus, wing length, and asymmetry), immunocompetence (cutaneous immunity, heterophil/lymphocyte ratio, and humoral immunity), or feather coloration. One week subsequent to implant removal, however, differences were detected. Sham-implanted birds had significantly longer wings and a reduced level of cutaneous immune function compared with those of birds given corticosterone-filled implants. Therefore, increases of only 2 ng/mL in basal corticosterone titer can have small but measurable effects on subsequent avian development.
Pozzi, Alessandro; Arcuri, Lorenzo; Moy, Peter K
2018-03-01
The growing interest in minimally invasive implant placement and delivery of a prefabricated provisional prosthesis immediately, thus minimizing "time to teeth," has led to the development of numerous 3-dimensional (3D) planning software programs. Given the enhancements associated with fully digital workflows, such as better 3D soft-tissue visualization and virtual tooth rendering, computer-guided implant surgery and immediate function has become an effective and reliable procedure. This article describes how modern implant planning software programs provide a comprehensive digital platform that enables efficient interplay between the surgical and restorative aspects of implant treatment. These new technologies that streamline the overall digital workflow allow transformation of the digital wax-up into a personalized, CAD/CAM-milled provisional restoration. Thus, collaborative digital workflows provide a novel approach for time-efficient delivery of a customized, screw-retained provisional restoration on the day of implant surgery, resulting in improved predictability for immediate function in the partially edentate patient.
Gaiarsa, Guilherme Pelosini; dos Reis, Paulo Roberto; Mattar, Rames; Silva, Jorge dos Santos; Fernandez, Túlio Diniz
2015-01-01
ABSTRACT Objective: To compare the functional results of ankle fractures treated with metallic and absorbable plates. Twenty patients were randomized into two groups (metallic and absorbable implant groups) and followed prospectively. In the immediate postoperative period, patients were immobilized with plaster casts for one week, which was replaced by a removable cast for another four weeks. Partial weight-bearing was allowed after three weeks, and full weight-bearing after six weeks. Functional recovery was similar in both groups. At six months, three patients in the metallic group complained of local pain, and had their implants removed. One patient in the absorbable group exhibited early dehiscence of the suture and underwent debridement and suturing with good evolution. The American Orthopaedic Foot and Ankle Society (AOFAS) score was similar between the two groups after six and nine months of follow-up. The absorbable implants showed clinical and functional results that were similar to those of metallic implants. Level of Evidence II, Prospective Comparative Study. PMID:26981035
Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.
Bernhart, Gunda; Koob, Andreas; Schmitter, Marc; Gabbert, Olaf; Stober, Thomas; Rammelsberg, Peter
2012-08-01
The objective of this retrospective study was to compare biological and technical complications of implant-supported and tooth-implant-supported double crown-retained dentures (DCRDs) with those of tooth-supported DCRDs. Sixty-three DCRDs were monitored. One study group included 16 prostheses with a combination of implants and natural teeth as double crowns (ti group), whereas in the second study group, 19 dentures were retained exclusively on implants (ii group); a third study group with 28 exclusively tooth-supported dentures served as controls (tt group). Tooth loss, implant failure, and technical complications (loss of retention of primary crown, abutment screw loosening, loss of facing, fracture of resin denture teeth and fracture of saddle resin) were analysed. During the observation period of 24 months, no implants or teeth were lost in the ti group and three technical complications were recorded. In the ii group, two implants were lost, two cases of peri-implantitis occurred and four technical complications were observed. In the tt group, two cases of tooth loss and seven technical complications were observed. At the time of the last examination, all prostheses of the ti group and the ii group were functional. Patients of these two study groups reported high satisfaction with both function and aesthetics with no significant difference between the two groups. Treatment with DCRDs showed comparable results in the three study groups. The 2-year results indicate that double crowns can be recommended for implant and combined tooth-implant-retained dentures.
Energy acceptance and on momentum aperture optimization for the Sirius project
NASA Astrophysics Data System (ADS)
Dester, P. S.; Sá, F. H.; Liu, L.
2017-07-01
A fast objective function to calculate Touschek lifetime and on momentum aperture is essential to explore the vast search space of strength of quadrupole and sextupole families in Sirius. Touschek lifetime is estimated by using the energy aperture (dynamic and physical), RF system parameters and driving terms. Non-linear induced betatron oscillations are considered to determine the energy aperture. On momentum aperture is estimated by using a chaos indicator and resonance crossing considerations. Touschek lifetime and on momentum aperture constitute the objective function, which was used in a multi-objective genetic algorithm to perform an optimization for Sirius.
Daviss, W Burleson; Diler, Rasim S
2014-11-01
To examine potential predictors of lifetime suicidal behaviors (SBs) in adolescents with ADHD. Participants were 101 adolescents with ADHD aged 11 to 18 years, evaluated for lifetime SB and psychopathology with semistructured interviews, and for lifetime trauma exposure, parent-child conflict, ADHD symptoms, and functional impairment with child, parent, and teacher ratings. Controlling for the effects of age, female sex, and comorbid depressive and other disorders, lifetime SB (n = 28) remained significantly associated (p = .001) with parent-child conflict, and to a lesser extent (p < .05) with impairment in nonacademic domains of function and breadth of exposure to victimization events. Measures related to past and current ADHD symptoms and signs were not associated with lifetime SB. Apart from depression, clinicians should pay particular attention to parent-child conflict, victimization trauma, and social impairment rather than levels of ADHD symptoms when weighing the likelihood of SB in youth with ADHD. © 2012 SAGE Publications.
Analysis of positron lifetime spectra in polymers
NASA Technical Reports Server (NTRS)
Singh, Jag J.; Mall, Gerald H.; Sprinkle, Danny R.
1988-01-01
A new procedure for analyzing multicomponent positron lifetime spectra in polymers was developed. It requires initial estimates of the lifetimes and the intensities of various components, which are readily obtainable by a standard spectrum stripping process. These initial estimates, after convolution with the timing system resolution function, are then used as the inputs for a nonlinear least squares analysis to compute the estimates that conform to a global error minimization criterion. The convolution integral uses the full experimental resolution function, in contrast to the previous studies where analytical approximations of it were utilized. These concepts were incorporated into a generalized Computer Program for Analyzing Positron Lifetime Spectra (PAPLS) in polymers. Its validity was tested using several artificially generated data sets. These data sets were also analyzed using the widely used POSITRONFIT program. In almost all cases, the PAPLS program gives closer fit to the input values. The new procedure was applied to the analysis of several lifetime spectra measured in metal ion containing Epon-828 samples. The results are described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schrof, Julian; Müller, Ralph; Reedy, Robert C.
2015-07-28
Boron diffusivity reduction in extrinsically doped silicon was investigated in the context of a process combination consisting of BBr3 furnace diffusion and preceding Phosphorus ion implantation. The implantation of Phosphorus leads to a substantial blocking of Boron during the subsequent Boron diffusion. First, the influences of ion implantation induced point defects as well as the initial P doping on B diffusivity were studied independently. Here, it was found that not the defects created during ion implantation but the P doping itself results in the observed B diffusion retardation. The influence of the initial P concentration was investigated in more detailmore » by varying the P implantation dose. A secondary ion mass spectrometry (SIMS) analysis of the BSG layer after the B diffusion revealed that the B diffusion retardation is not due to potential P content in the BSG layer but rather caused by the n-type doping of the crystalline silicon itself. Based on the observations the B diffusion retardation was classified into three groups: (i) no reduction of B diffusivity, (ii) reduced B diffusivity, and (iii) blocking of the B diffusion. The retardation of B diffusion can well be explained by the phosphorus doping level resulting in a Fermi level shift and pairing of B and P ions, both reducing the B diffusivity. Besides these main influences, there are probably additional transient phenomena responsible for the blocking of boron. Those might be an interstitial transport mechanism caused by P diffusion that reduces interstitial concentration at the surface or the silicon/BSG interface shift due to oxidation during the BBr3 diffusion process. Lifetime measurements revealed that the residual (non-blocked) B leads to an increased dark saturation current density in the P doped region. Nevertheless, electrical quality is on a high level and was further increased by reducing the B dose as well as by removing the first few nanometers of the silicon surface after the BBr3 diffusion« less
Successful pacing using a batteryless sunlight-powered pacemaker.
Haeberlin, Andreas; Zurbuchen, Adrian; Schaerer, Jakob; Wagner, Joerg; Walpen, Sébastien; Huber, Christoph; Haeberlin, Heinrich; Fuhrer, Juerg; Vogel, Rolf
2014-10-01
Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P < 0.001). Finally, a batteryless single-chamber pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Long, Jason P.; Hollister, Scott J.; Goldstein, Steven A.
2012-01-01
While contemporary prosthetic devices restore some function to individuals who have lost a limb, there are efforts to develop bio-integrated prostheses to improve functionality. A critical step in advancing this technology will be to securely attach the device to remnant bone. To investigate mechanisms for establishing robust implant fixation in bone while undergoing loading, we previously used a topology optimization scheme to develop optimized orthopaedic implants and then fabricated selected designs from titanium (Ti)-alloy with selective laser sintering (SLS) technology. In the present study, we examined how implant architecture and mechanical stimulation influence osseointegration within an in vivo environment. To do this, we evaluated three implant designs (two optimized and one non-optimized) using a unique in vivo model that applied cyclic, tension/ compression loads to the implants. Eighteen (six per implant design) adult male canines had implants surgically placed in their proximal, tibial metaphyses. Experimental duration was 12 weeks; daily loading (peak load of ±22N for 1000 cycles) was applied to one of each animal’s bilateral implants for the latter six weeks. Following harvest, osseointegration was assessed by non-destructive mechanical testing, micro-computed tomography (microCT) and back-scatter scanning electron microscopy (SEM). Data revealed that implant loading enhanced osseointegration by significantly increasing construct stiffness, peri-implant trabecular morphology, and percentages of interface connectivity and bone ingrowth. While this experiment did not demonstrate a clear advantage associated with the optimized implant designs, osseointegration was found to be significantly influenced by aspects of implant architecture. PMID:22951278
Long, Jason P; Hollister, Scott J; Goldstein, Steven A
2012-10-11
While contemporary prosthetic devices restore some function to individuals who have lost a limb, there are efforts to develop bio-integrated prostheses to improve functionality. A critical step in advancing this technology will be to securely attach the device to remnant bone. To investigate mechanisms for establishing robust implant fixation in bone while undergoing loading, we previously used a topology optimization scheme to develop optimized orthopedic implants and then fabricated selected designs from titanium (Ti)-alloy with selective laser sintering (SLS) technology. In the present study, we examined how implant architecture and mechanical stimulation influence osseointegration within an in vivo environment. To do this, we evaluated three implant designs (two optimized and one non-optimized) using a unique in vivo model that applied cyclic, tension/compression loads to the implants. Eighteen (six per implant design) adult male canines had implants surgically placed in their proximal, tibial metaphyses. Experimental duration was 12 weeks; daily loading (peak load of ±22 N for 1000 cycles) was applied to one of each animal's bilateral implants for the latter six weeks. Following harvest, osseointegration was assessed by non-destructive mechanical testing, micro-computed tomography (microCT) and back-scatter scanning electron microscopy (SEM). Data revealed that implant loading enhanced osseointegration by significantly increasing construct stiffness, peri-implant trabecular morphology, and percentages of interface connectivity and bone ingrowth. While this experiment did not demonstrate a clear advantage associated with the optimized implant designs, osseointegration was found to be significantly influenced by aspects of implant architecture. Copyright © 2012 Elsevier Ltd. All rights reserved.
Razaghi, Reza; Biglari, Hasan; Karimi, Alireza
2017-05-01
The long-term application of dental prostheses inside the bone has a narrow relation to its biomechanical performance. Chewing is the most complicated function of a dental implant as it implements different forces to the implant at various directions. Therefore, a suitable holistic modelling of the jaw bone, implant, food, muscles, and their forces would be deemed significant to figure out the durability as well as functionality of a dental implant while chewing. So far, two approaches have been proposed to employ the muscle forces into the Finite Element (FE) models, i.e. Muscle Equivalent Force (MEF) and trajectory. This study aimed at propounding a new three-dimensional dynamic FE model based on two muscle forces modelling approaches in order to investigate the stresses and deformations in the dental prosthesis as well as maxillary bone during the time of chewing a cornflakes bio. The results revealed that both contact and the maximum von Mises stress in the implant and bones for trajectory approach considerably exceed those of the MEF. The maximum stresses, moreover, are located around the neck of implant which should be both clinically and structurally strong enough to functionally maintain the bone-implant interface. In addition, a higher displacement due to compressive load is observed for the implant head in trajectory approach. The results suggest the benefits provided by trajectory approach since MEF approach would significantly underestimate the stresses and deformations in both the dental prosthesis and bones.
Vestibulo-ocular and vestibulospinal function before and after cochlear implant surgery
NASA Technical Reports Server (NTRS)
Black, F. O.; Lilly, D. J.; Peterka, R. J.; Fowler, L. P.; Simmons, F. B.
1987-01-01
Vestibular function in cochlear implant candidates varies from normal to total absence of function. In patients with intact vestibular function preoperatively, invasion of the otic capsule places residual vestibular function at risk. Speech-processing strategies that result in large amplitude electrical transients or strategies that employ high amplitude broad frequency carrier signals have the potential for disrupting vestibular function. Five patients were tested with and without electrical stimulation via cochlear electrodes. Two patients experienced subjective vestibular effects that were quickly resolved. No long-term vestibular effects were noted for the two types of second generation cochlear implants evaluated. Histopathological findings from another patient, who had electrically generated vestibular reflex responses to intramodiolar electrodes, indicated that responses elicited were a function of several variables including electrode location, stimulus intensity, stimulus amplitude, and stimulus frequency. Differential auditory, vestibulocolic, and vestibulospinal reflexes were demonstrated from the same electrode as a function of stimulus amplitude, frequency, and duration.
2015-10-01
function for individuals with cervical SCI. This study will utilize the “networked neuroprosthesis” (NNP). The NNP system is completely implanted...individuals with cervical SCI. We have completed a clinical feasibility study of a neuroprosthesis that provides myoelectrically-controlled hand...by this proposal) cervical level spinal cord injured subjects and evaluate the resulting improvement in upper extremity function. Compare functional
Gruenbaum, S M; Skinner, J L
2011-08-21
The vibrational spectroscopy of hydration water in dilauroylphosphatidylcholine lipid multi-bilayers is investigated using molecular dynamics simulations and a mixed quantum/classical model for the OD stretch spectroscopy of dilute HDO in H(2)O. FTIR absorption spectra, and isotropic and anisotropic pump-probe decay curves have been measured experimentally as a function of the hydration level of the lipid multi-bilayer, and our goal is to make connection with these experiments. To this end, we use third-order response functions, which allow us to include non-Gaussian frequency fluctuations, non-Condon effects, molecular rotations, and a fluctuating vibrational lifetime, all of which we believe are important for this system. We calculate the response functions using existing transition frequency and dipole maps. From the experiments it appears that there are two distinct vibrational lifetimes corresponding to HDO molecules in different molecular environments. In order to obtain these lifetimes, we consider a simple two-population model for hydration water hydrogen bonds. Assuming a different lifetime for each population, we then calculate the isotropic pump-probe decay, fitting to experiment to obtain the two lifetimes for each hydration level. With these lifetimes in hand, we then calculate FTIR spectra and pump-probe anisotropy decay as a function of hydration. This approach, therefore, permits a consistent calculation of all observables within a unified computational scheme. Our theoretical results are all in qualitative agreement with experiment. The vibrational lifetime of lipid-associated OD groups is found to be systematically shorter than that of the water-associated population, and the lifetimes of each population increase with decreasing hydration, in agreement with previous analysis. Our theoretical FTIR absorption spectra successfully reproduce the experimentally observed red-shift with decreasing lipid hydration, and we confirm a previous interpretation that this shift results from the hydrogen bonding of water to the lipid phosphate group. From the pump-probe anisotropy decay, we confirm that the reorientational motions of water molecules slow significantly as hydration decreases, with water bound in the lipid carbonyl region undergoing the slowest rotations. © 2011 American Institute of Physics
Gruenbaum, S. M.; Skinner, J. L.
2011-01-01
The vibrational spectroscopy of hydration water in dilauroylphosphatidylcholine lipid multi-bilayers is investigated using molecular dynamics simulations and a mixed quantum∕classical model for the OD stretch spectroscopy of dilute HDO in H2O. FTIR absorption spectra, and isotropic and anisotropic pump-probe decay curves have been measured experimentally as a function of the hydration level of the lipid multi-bilayer, and our goal is to make connection with these experiments. To this end, we use third-order response functions, which allow us to include non-Gaussian frequency fluctuations, non-Condon effects, molecular rotations, and a fluctuating vibrational lifetime, all of which we believe are important for this system. We calculate the response functions using existing transition frequency and dipole maps. From the experiments it appears that there are two distinct vibrational lifetimes corresponding to HDO molecules in different molecular environments. In order to obtain these lifetimes, we consider a simple two-population model for hydration water hydrogen bonds. Assuming a different lifetime for each population, we then calculate the isotropic pump-probe decay, fitting to experiment to obtain the two lifetimes for each hydration level. With these lifetimes in hand, we then calculate FTIR spectra and pump-probe anisotropy decay as a function of hydration. This approach, therefore, permits a consistent calculation of all observables within a unified computational scheme. Our theoretical results are all in qualitative agreement with experiment. The vibrational lifetime of lipid-associated OD groups is found to be systematically shorter than that of the water-associated population, and the lifetimes of each population increase with decreasing hydration, in agreement with previous analysis. Our theoretical FTIR absorption spectra successfully reproduce the experimentally observed red-shift with decreasing lipid hydration, and we confirm a previous interpretation that this shift results from the hydrogen bonding of water to the lipid phosphate group. From the pump-probe anisotropy decay, we confirm that the reorientational motions of water molecules slow significantly as hydration decreases, with water bound in the lipid carbonyl region undergoing the slowest rotations. PMID:21861584
DEALING WITH DENTAL IMPLANT FAILURES
Levin, Liran
2008-01-01
An implant-supported restoration offers a predictable treatment for tooth replacement. Reported success rates for dental implants are high. Nevertheless, failures that mandate immediate implant removal do occur. The consequences of implant removal jeopardize the clinician's efforts to accomplish satisfactory function and esthetics. For the patient, this usually involves further cost and additional procedures. The aim of this paper is to describe different methods and treatment modalities to deal with dental implant failure. The main topics for discussion include identifying the failing implant, implants replacing failed implants at the exact site, and the use of other restorative options. When an implant fails, a tailor made treatment plan should be provided to each patient according to all relevant variables. Patients should be informed regarding all possible treatment modalities following implant failure and give their consent to the most appropriate treatment option for them. PMID:19089213
Lifetime Costs of Prophylactic Mastectomies and Reconstruction versus Surveillance.
Mattos, David; Gfrerer, Lisa; Reish, Richard G; Hughes, Kevin S; Cetrulo, Curtis; Colwell, Amy S; Winograd, Jonathan M; Yaremchuk, Michael J; Austen, William G; Liao, Eric C
2015-12-01
The past decade has seen an increasing prevalence of prophylactic mastectomy with decreasing ages of patients treated for breast cancer. Data are limited on the fiscal impacts of contralateral prophylactic mastectomy trends, and no study has compared bilateral prophylactic mastectomy with reconstruction to surveillance in high-risk patients. Lifetime third-party payer costs over 30 years were estimated with 2013 Medicare reimbursement rates. Costs were estimated for patients choosing contralateral or bilateral prophylactic mastectomy versus surveillance, with immediate reconstructions using a single-stage implant, tissue expander, or perforator-based free flap approach. Published cancer incidence rates predicted the percentage of surveillance patients that would require mastectomies. Sensitivity analyses were conducted that varied cost growth, discount rate, cancer incidence rate, and other variables. Lifetime costs and present values (3 percent discount rate) were estimated. Lifetime prophylactic mastectomy costs were lower than surveillance costs, $1292 to $1993 lower for contralateral prophylactic mastectomy and $15,668 to $21,342 lower for bilateral prophylactic mastectomy, depending on the reconstruction. Present value estimates were slightly higher for contralateral prophylactic mastectomy over contralateral surveillance but still cost saving for bilateral prophylactic mastectomy compared with bilateral surveillance. Present value estimates are also cost saving for contralateral prophylactic mastectomy when the modeled contralateral breast cancer incidence rate is increased to at least 0.6 percent per year. These findings are consistent with contralateral and bilateral prophylactic mastectomy being cost saving in many scenarios, regardless of the reconstructive option chosen. They suggest that physicians and patients should continue to receive flexibility in deciding how best to proceed clinically in each case.
[Self-expandable metallic biliary endoprosthesis in malignant obstructive jaundice].
Güitrón-Cantú, Alfredo; Adalid-Martínez, Raúl; Gutiérrez-Bermúdez, José A
2005-01-01
Implantation of metallic stents for malignant biliary strictures has been recognized to be effective alternatives. To show our experience in metallic stents for palliation of malignant biliary strictures. Seventy three patients (38 males, 35 females, mean age 64.26) with malignant biliary strictures have been treated by implantation of metallic stents. Causes of obstruction were pancreatic carcinoma (23/73, 31.5%), bile duct carcinoma (31/73, 42.5%), carcinoma of ampula of Vater (11/73, 15%) and Klatskin tumor (3/73, 4.1%). Endoscopic procedure was successful in all cases. Neither procedure-related morbidity nor mortality was observed. Life surviving curve was 9 months and showed significant difference (p < 0.0071) in patients with carcinoma of ampula of Vater. Self-expanding metal endoprosthesis is a recognized method of palliation in malignant biliary obstruction. It efficiently relieves jaundice and generally improves comfort and nutritional status during the patient's remaining lifetime. The metallic stents are advantageous in patients surviving 6 months or less.
NASA Astrophysics Data System (ADS)
Megherbi, M. L.; Pezzimenti, F.; Dehimi, L.; Rao, S.; Della Corte, F. G.
2015-07-01
In this work different experimental current-voltage behaviours of several Al implanted 4H-SiC p-i-n diodes are investigated by means of numerical simulations in a wide range of currents and temperatures. Some devices for which recombination and tunneling are the dominant current processes at all biases are classified as "leaky" diodes. The well behaved diodes, instead, show good rectifying characteristics with a current conduction due to tunneling below 1.7 V, recombination between 1.7 V and 2.5 V, and diffusion processes above 2.5 V. At higher current regimes, a series resistance in excess of 1 mΩ cm2 becomes the main current limiting factor. Depending on the relative weight between the contact resistances and the internal diode resistance, different temperature dependencies of the current are obtained. A good agreement between numerical and measured data is achieved employing temperature-dependent carrier lifetime and mobility as fitting parameters.
Switchable Polymer Based Thin Film Coils as a Power Module for Wireless Neural Interfaces.
Kim, S; Zoschke, K; Klein, M; Black, D; Buschick, K; Toepper, M; Tathireddy, P; Harrison, R; Solzbacher, F
2007-05-01
Reliable chronic operation of implantable medical devices such as the Utah Electrode Array (UEA) for neural interface requires elimination of transcutaneous wire connections for signal processing, powering and communication of the device. A wireless power source that allows integration with the UEA is therefore necessary. While (rechargeable) micro batteries as well as biological micro fuel cells are yet far from meeting the power density and lifetime requirements of an implantable neural interface device, inductive coupling between two coils is a promising approach to power such a device with highly restricted dimensions. The power receiving coils presented in this paper were designed to maximize the inductance and quality factor of the coils and microfabricated using polymer based thin film technologies. A flexible configuration of stacked thin film coils allows parallel and serial switching, thereby allowing to tune the coil's resonance frequency. The electrical properties of the fabricated coils were characterized and their power transmission performance was investigated in laboratory condition.
In situ regeneration of bioactive coatings enabled by an evolved Staphylococcus aureus sortase A
NASA Astrophysics Data System (ADS)
Ham, Hyun Ok; Qu, Zheng; Haller, Carolyn A.; Dorr, Brent M.; Dai, Erbin; Kim, Wookhyun; Liu, David R.; Chaikof, Elliot L.
2016-04-01
Surface immobilization of bioactive molecules is a central paradigm in the design of implantable devices and biosensors with improved clinical performance capabilities. However, in vivo degradation or denaturation of surface constituents often limits the long-term performance of bioactive films. Here we demonstrate the capacity to repeatedly regenerate a covalently immobilized monomolecular thin film of bioactive molecules through a two-step stripping and recharging cycle. Reversible transpeptidation by a laboratory evolved Staphylococcus aureus sortase A (eSrtA) enabled the rapid immobilization of an anti-thrombogenic film in the presence of whole blood and permitted multiple cycles of film regeneration in vitro that preserved its biological activity. Moreover, eSrtA transpeptidation facilitated surface re-engineering of medical devices in situ after in vivo implantation through removal and restoration film constituents. These studies establish a rapid, orthogonal and reversible biochemical scheme to regenerate selective molecular constituents with the potential to extend the lifetime of bioactive films.
Wireless Microstimulators for Neural Prosthetics
Sahin, Mesut; Pikov, Victor
2016-01-01
One of the roadblocks in the field of neural prosthetics is the lack of microelectronic devices for neural stimulation that can last a lifetime in the central nervous system. Wireless multi-electrode arrays are being developed to improve the longevity of implants by eliminating the wire interconnects as well as the chronic tissue reactions due to the tethering forces generated by these wires. An area of research that has not been sufficiently investigated is a simple single-channel passive microstimulator that can collect the stimulus energy that is transmitted wirelessly through the tissue and immediately convert it into the stimulus pulse. For example, many neural prosthetic approaches to intraspinal microstimulation require only a few channels of stimulation. Wired spinal cord implants are not practical for human subjects because of the extensive flexions and rotations that the spinal cord experiences. Thus, intraspinal microstimulation may be a pioneering application that can benefit from submillimetersize floating stimulators. Possible means of energizing such a floating microstimulator, such as optical, acoustic, and electromagnetic waves, are discussed. PMID:21488815
Pileggi, Antonello; Molano, R Damaris; Ricordi, Camillo; Zahr, Elsie; Collins, Jill; Valdes, Rafael; Inverardi, Luca
2006-05-15
Transplantation of pancreatic islets for the treatment of type 1 diabetes allows for physiologic glycemic control and insulin-independence when sufficient islets are implanted via the portal vein into the liver. Intrahepatic islet implantation requires specific infrastructure and expertise, and risks inherent to the procedure include bleeding, thrombosis, and elevation of portal pressure. Additionally, the relatively higher drug metabolite concentrations in the liver may contribute to the delayed loss of graft function of recent clinical trials. Identification of alternative implantation sites using biocompatible devices may be of assistance improving graft outcome. A desirable bioartificial pancreas should be easy to implant, biopsy, and retrieve, while allowing for sustained graft function. The subcutaneous (SC) site may require a minimally invasive procedure performed under local anesthesia, but its use has been hampered so far by lack of early vascularization, induction of local inflammation, and mechanical stress on the graft. Chemically diabetic rats received syngeneic islets into the liver or SC into a novel biocompatible device consisting of a cylindrical stainless-steel mesh. The device was implanted 40 days prior to islet transplantation to allow embedding by connective tissue and neovascularization. Reversal of diabetes and glycemic control was monitored after islet transplantation. Syngeneic islets transplanted into a SC, neovascularized device restored euglycemia and sustained function long-term. Removal of graft-bearing devices resulted in hyperglycemia. Explanted grafts showed preserved islets and intense vascular networks. Ease of implantation, biocompatibility, and ability to maintain long-term graft function support the potential of our implantable device for cellular-based reparative therapies.
New developments in functional medical textiles and their mechanism of action
USDA-ARS?s Scientific Manuscript database
Functional medical textiles are undergoing a revolution in structural design. Medical textiles as non-implantables, implantables, and extracorporeals, are playing central roles in healthcare improvements enhancing and prolonging the quality of life. Developments in the design of materials that funct...
Multicompartment Drug Release System for Dynamic Modulation of Tissue Responses.
Morris, Aaron H; Mahal, Rajwant S; Udell, Jillian; Wu, Michelle; Kyriakides, Themis R
2017-10-01
Pharmacological modulation of responses to injury is complicated by the need to deliver multiple drugs with spatiotemporal resolution. Here, a novel controlled delivery system containing three separate compartments with each releasing its contents over different timescales is fabricated. Core-shell electrospun fibers create two of the compartments in the system, while electrosprayed spheres create the third. Utility is demonstrated by targeting the foreign body response to implants because it is a dynamic process resulting in implant failure. Sequential delivery of a drug targeting nuclear factor-κB (NF-κB) and an antifibrotic is characterized in in vitro experiments. Specifically, macrophage fusion and p65 nuclear translocation in the presence of releasate or with macrophages cultured on the surfaces of the constructs are evaluated. In addition, releasate from pirfenidone scaffolds is shown to reduce transforming growth factor-β (TGF-β)-induced pSMAD3 nuclear localization in fibroblasts. In vivo, drug eluting constructs successfully mitigate macrophage fusion at one week and fibrotic encapsulation in a dose-dependent manner at four weeks, demonstrating effective release of both drugs over different timescales. Future studies can employ this system to improve and prolong implant lifetimes, or load it with other drugs to modulate other dynamic processes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Scholten, Kee; Meng, Ellis
2018-06-15
Closed-loop drug delivery promises autonomous control of pharmacotherapy through the continuous monitoring of biomarker levels. For decades, researchers have strived for portable closed-loop systems capable of treating ambulatory patients with chronic conditions such as diabetes mellitus. After years of development, the first of these systems have left the laboratory and entered commercial use. This long-awaited advance reflects recent development of chronically stable implantable biosensors able to accurately measure biomarker levels in vivo. This review discusses the role of implantable biosensors in closed-loop drug delivery applications, with the intent to provide a resource for engineers and researchers studying such systems. We provide an overview of common biosensor designs and review the principle challenges in implementing long indwelling sensors: namely device sensitivity, selectivity, and lifetime. This review examines novel advances in transducer design, biological interface, and material biocompatibility, with a focus on recent academic and commercial work which provide successful strategies to overcome perennial challenges. This review focuses primarily on the topics of closed-loop glucose control and continuous glucose monitoring biosensors, which make up the overwhelming majority of published research in this area. We conclude with an overview of recent advances in closed-loop systems targeting applications outside blood glucose management. Copyright © 2018 Elsevier B.V. All rights reserved.
Wang, Ning; Burugapalli, Krishna; Wijesuriya, Shavini; Far, Mahshid Yazdi; Song, Wenhui; Moussy, Francis; Zheng, Yudong; Ma, Yanxuan; Wu, Zhentao; Li, Kang
2014-01-01
The aim of this study was to introduce bioactivity to the electrospun coating for implantable glucose biosensors. Coaxial fibre membranes having polyurethane as the core and gelatin as the shell were produced using a range of polyurethane concentrations (2, 4, 6 & 8% wt/v) while keeping gelatin concentration (10% wt/v) constant in 2,2,2-trifluoroethanol. The gelatin shell was stabilized using glutaraldehyde vapour. The formation of core-shell structure was confirmed using TEM, SEM and FTIR. The coaxial fibre membranes showed uniaxial tensile properties intermediate to that of the pure polyurethane and the gelatin fibre membranes. The gelatin shell increased hydrophilicity and glucose transport flux across the coaxial fibre membranes. The coaxial fibre membranes having small fibre diameter (541 nm) and a thick gelatin shell (52%) did not affect the sensor sensitivity, but decreased sensor’s linearity in the long run. In contrast, thicker coaxial fibre membranes (1133 nm) having a thin gelatin shell (34%) maintained both sensitivity and linearity till 84 days of the study period. To conclude, polyurethane-gelatin co-axial fibre membranes, due to their faster permeability to glucose, tailorable mechanical properties and bioactivity are potential candidates for coatings to favourably modify the host responses to extend the reliable in vivo lifetime of implantable glucose biosensors. PMID:24346001
NASA Astrophysics Data System (ADS)
Li, Jing; Ye, Jiandong; Ren, Fangfang; Tang, Dongming; Yang, Yi; Tang, Kun; Gu, Shulin; Zhang, Rong; Zheng, Youdou
2017-03-01
The demand for high efficiency intermediate band (IB) solar cells is driving efforts in producing high quality IB photovoltaic materials. Here, we demonstrate ZnTe:O highly mismatched alloys synthesized by high dose ion implantation and pulsed laser melting exhibiting optically active IB states and efficient sub-gap photoresponse, as well as investigate the effect of pulsed laser melting on the structural and optical recovery in detail. The structural evolution and vibrational dynamics indicates a significant structural recovery of ZnTe:O alloys by liquid phase epitaxy during pulsed laser melting process, but laser irradiation also aggravates the segregation of Te in ZnTe:O alloys. A distinct intermediate band located at 1.8 eV above valence band is optically activated as evidenced by photoluminescence, absorption and photoresponse characteristics. The carrier dynamics indicates that carriers in the IB electronic states have a relatively long lifetime, which is beneficial for the fast separation of carriers excited by photons with sub-gap energy and thus the improved overall conversion efficiency. The reproducible capability of implantation and laser annealing at selective area enable the realization of high efficient lateral junction solar cells, which can ensure extreme light trapping and efficient charge separation.
Capella, Maria del Mar; Prat, Gemma; Forero, Diego A.; López-Vera, Silvia; Navarro, José Francisco
2017-01-01
Background Lifetime suicide attempts in patients with comorbidity between psychotic disorders and Substance Use Disorder (SUD), known as dual diagnosis, was associated with a worse clinical and cognitive state, poor prognosis and premature death. However, to date no previous study has examined the cognitive performance of these patients considering as independent the presence or absence of lifetime suicide attempts. Methods We explore executive functioning differences between suicide attempters and non-attempters in dual schizophrenia (DS) patients and the possible related factors for both executive performance and current suicide risk. Fifty DS male patients in remission of SUD and clinically stables, 24 with and 26 without lifetime suicide attempts, were evaluated. We considered Z scores for all neuropsychological tests and a composite summary score for both premorbid IQ and executive functioning. Results DS patients showed low performance in set-shifting, planning and problem solving tasks. Those with suicide attempts presented lower composite summary scores, together with worse problem solving skills and decision-making, compared with non-attempters. However, after controlling for alcohol dependence, only differences in decision-making remained. Executive functioning was related to the premorbid intelligence quotient, and several clinical variables (duration, severity, months of abstinence and relapses of SUD, global functioning and negative symptoms). A relationship between current suicide risk, and first-degree relatives with SUD, insight and positive symptoms was also found. Conclusions Our results suggest that problem solving and, especially, decision-making tasks might be sensitive to cognitive impairment of DS patients related to presence of lifetime suicide attempts. The assessment of these executive functions and cognitive remediation therapy when necessary could be beneficial for the effectiveness of treatment in patients with DS. However, further research is needed to expand our findings and overcome some limitations of this study. PMID:28099526
Adan, Ana; Capella, Maria Del Mar; Prat, Gemma; Forero, Diego A; López-Vera, Silvia; Navarro, José Francisco
2017-01-01
Lifetime suicide attempts in patients with comorbidity between psychotic disorders and Substance Use Disorder (SUD), known as dual diagnosis, was associated with a worse clinical and cognitive state, poor prognosis and premature death. However, to date no previous study has examined the cognitive performance of these patients considering as independent the presence or absence of lifetime suicide attempts. We explore executive functioning differences between suicide attempters and non-attempters in dual schizophrenia (DS) patients and the possible related factors for both executive performance and current suicide risk. Fifty DS male patients in remission of SUD and clinically stables, 24 with and 26 without lifetime suicide attempts, were evaluated. We considered Z scores for all neuropsychological tests and a composite summary score for both premorbid IQ and executive functioning. DS patients showed low performance in set-shifting, planning and problem solving tasks. Those with suicide attempts presented lower composite summary scores, together with worse problem solving skills and decision-making, compared with non-attempters. However, after controlling for alcohol dependence, only differences in decision-making remained. Executive functioning was related to the premorbid intelligence quotient, and several clinical variables (duration, severity, months of abstinence and relapses of SUD, global functioning and negative symptoms). A relationship between current suicide risk, and first-degree relatives with SUD, insight and positive symptoms was also found. Our results suggest that problem solving and, especially, decision-making tasks might be sensitive to cognitive impairment of DS patients related to presence of lifetime suicide attempts. The assessment of these executive functions and cognitive remediation therapy when necessary could be beneficial for the effectiveness of treatment in patients with DS. However, further research is needed to expand our findings and overcome some limitations of this study.
Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries
Singh, Charanpreet; Wong, Cynthia S.; Wang, Xungai
2015-01-01
Vascular implants belong to a specialised class of medical textiles. The basic purpose of a vascular implant (graft and stent) is to act as an artificial conduit or substitute for a diseased artery. However, the long-term healing function depends on its ability to mimic the mechanical and biological behaviour of the artery. This requires a thorough understanding of the structure and function of an artery, which can then be translated into a synthetic structure based on the capabilities of the manufacturing method utilised. Common textile manufacturing techniques, such as weaving, knitting, braiding, and electrospinning, are frequently used to design vascular implants for research and commercial purposes for the past decades. However, the ability to match attributes of a vascular substitute to those of a native artery still remains a challenge. The synthetic implants have been found to cause disturbance in biological, biomechanical, and hemodynamic parameters at the implant site, which has been widely attributed to their structural design. In this work, we reviewed the design aspect of textile vascular implants and compared them to the structure of a natural artery as a basis for assessing the level of success as an implant. The outcome of this work is expected to encourage future design strategies for developing improved long lasting vascular implants. PMID:26133386
Effect of cochlear implantation on middle ear function: A three-month prospective study.
Wasson, Joseph D; Campbell, Luke; Chambers, Scott; Hampson, Amy; Briggs, Robert J S; O'Leary, Stephen J
2018-05-01
To determine if cochlear implantation has a delayed effect on the middle ear conductive hearing mechanism by measuring laser Doppler vibrometry (LDV) of the tympanic membrane (TM) in both implanted and contralateral control ears preoperatively and 3 months postoperatively, and then comparing the relative change in LDV outcome measures between implanted and control ears. Prospective cohort study. Eleven preoperative adult unilateral cochlear implant recipients in previously unoperated ears with normal anatomy and aerated temporal bones were included in this study. The magnitude and phase angle of umbo velocity transfer function in response to air- conduction (AC) stimulus, and the magnitude of umbo velocity in response to bone- conduction (BC) stimulus were measured in the implant ear and the contralateral control ear preoperatively and 3 months postoperatively and compared. No significant changes in the magnitude or phase angle of TM velocity in response to either AC or BC stimulus were observed in the implanted ear relative to the contralateral control ear 3 months following cochlear implantation. From the results of LDV measurements, it can be said that cochlear implantation has no significant delayed effect on the middle ear conductive mechanism. 4. Laryngoscope, 128:1207-1212, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Evidence-based guidelines for recommending cochlear implantation for postlingually deafened adults.
Leigh, Jaime R; Moran, Michelle; Hollow, Rodney; Dowell, Richard C
2016-01-01
Adult selection criteria for cochlear implantation have been developed based on analysis of the post-operative performance of a large group of postlingually deafened adults. Original criteria published in 2004 were reviewed and amended to reflect outcomes currently being achieved by implant recipients. Retrospective review of 12-month post-operative speech perception performance of adults implanted at the Eye and Ear Hospital, Melbourne, Australia. A total of 382 postlingually deafened adults, using a Freedom, Nucleus 5, or CI422 Slim Straight cochlear implant were used to create a comparative set of data. Revised guidelines suggest that adults with postlingual hearing loss can now be considered cochlear implant candidates if they obtain scores of up to 55% for open-set phonemes in quiet in the ear to be implanted. Functional benefit may vary depending on the recipients' contralateral hearing. This study supports the provision of cochlear implants to candidates with significant residual hearing when at least one ear meets the criterion outlined above. Patient-specific counseling is required to ensure the potential to benefit predicted by the current model is acceptable to the individual patient and their family. Counseling regarding functional benefit must take into consideration hearing in the contralateral ear.
Catelas, Isabelle; Lehoux, Eric A; Hurda, Ian; Baskey, Stephen J; Gala, Luca; Foster, Ryan; Kim, Paul R; Beaulé, Paul E
2015-12-01
Early adverse tissue reactions around metal-on-metal (MoM) hip replacements, especially pseudotumors, are a major concern. Because the causes and pathomechanisms of these pseudotumors remain largely unknown, clinical monitoring of patients with MoM bearings is challenging. The purpose of this study was to compare the lymphocyte subpopulations in peripheral blood from patients with a failed MoM hip implant with and without a pseudotumor and patients with a well-functioning MoM hip implant without a pseudotumor. Potential differences in the systemic immune response are expected to reflect local differences in the periprosthetic tissues. Consenting patients who underwent a revision of a failed MoM hip implant at The Ottawa Hospital (TOH) from 2011 to 2014, or presented with a well-functioning MoM hip implant for a postoperative clinical followup at TOH from 2012 to 2013, were recruited for this study, unless they met any of the exclusion criteria (including diagnosed conditions that can affect peripheral blood lymphocyte subpopulations). Patients with a failed implant were divided into two groups: those with a pseudotumor (two hip resurfacings and five total hip arthroplasties [THAs]) and those without a pseudotumor (10 hip resurfacings and two THAs). Patients with a well-functioning MoM hip implant (nine resurfacings and three THAs) at 5 or more years postimplantation and who did not have a pseudotumor as demonstrated sonographically served as the control group. Peripheral blood subpopulations of T cells (specifically T helper [Th] and cytotoxic T [Tc]), B cells, natural killer (NK) cells, memory T and B cells as well as type 1 (expressing interferon-γ) and type 2 (expressing interleukin-4) Th and Tc cells were analyzed by flow cytometry after immunostaining. Serum concentrations of cobalt and chromium were measured by inductively coupled plasma-mass spectrometry. The mean percentages of total memory T cells and, specifically, memory Th and memory Tc cells were lower in patients with a failed MoM hip implant with a pseudotumor than in both patients with a failed implant without a pseudotumor and patients with a well-functioning implant without a pseudotumor (memory Th cells: 29% ± 5% [means ± SD] versus 55% ± 17%, d = 1.8, 95% confidence interval [CI] [1.2, 2.5] and versus 48% ± 14%, d = 1.6, 95% CI [1.0, 2.2], respectively; memory Tc cells: 18% ± 5% versus 45% ± 14%, d = 2.3, 95% CI [1.5, 3.1] and versus 41% ± 12%, d = 2.3, 95% CI [1.5, 3.1], respectively; p < 0.001 in all cases). The mean percentage of memory B cells was also lower in patients with a failed MoM hip implant with a pseudotumor than in patients with a well-functioning implant without a pseudotumor (12% ± 8% versus 29% ± 16%, d = 1.3, 95% CI [0.7, 1.8], p = 0.025). In addition, patients with a failed MoM hip implant with a pseudotumor had overall lower percentages of type 1 Th cells than both patients with a failed implant without a pseudotumor and patients with a well-functioning implant without a pseudotumor (5.5% [4.9%-5.8%] [median with interquartile range] versus 8.7% [6.5%-10.2%], d = 1.4, 95% CI [0.8, 2.0] and versus 9.6% [6.4%-11.1%], d = 1.6, 95% CI [1.0, 2.2], respectively; p ≤ 0.010 in both cases). Finally, serum cobalt concentrations in patients with a failed MoM hip implant with a pseudotumor were overall higher than those in patients with a well-functioning implant without a pseudotumor (5.8 µg/L [2.9-17.0 µg/L] versus 0.9 µg/L [0.6-1.3 µg/L], d = 2.2, 95% CI [1.4, 2.9], p < 0.001). Overall, results suggest the presence of a type IV hypersensitivity reaction, with a predominance of type 1 Th cells, in patients with a failed MoM hip implant with a pseudotumor. The lower percentages of memory T cells (specifically Th and Tc) as well as type 1 Th cells in peripheral blood of patients with a failed MoM hip implant with a pseudotumor could potentially become diagnostic biomarkers for the detection of pseudotumors. Although implant design (hip resurfacing or THA) did not seem to affect the results, as suggested by the scatter of the data with respect to this parameter, future studies with additional patients could include the analysis of implant design in addition to correlations with histological analyses of specific Th subsets in periprosthetic tissues.
Degree of bioresorbable vascular scaffold expansion modulates loss of essential function.
Ferdous, Jahid; Kolachalama, Vijaya B; Kolandaivelu, Kumaran; Shazly, Tarek
2015-10-01
Drug-eluting bioresorbable vascular scaffolds (BVSs) have the potential to restore lumen patency, enable recovery of the native vascular environment, and circumvent late complications associated with permanent endovascular devices. To ensure therapeutic effects persist for sufficient times prior to scaffold resorption and resultant functional loss, many factors dictating BVS performance must be identified, characterized and optimized. While some factors relate to BVS design and manufacturing, others depend on device deployment and intrinsic vascular properties. Importantly, these factors interact and cannot be considered in isolation. The objective of this study is to quantify the extent to which degree of radial expansion modulates BVS performance, specifically in the context of modifying device erosion kinetics and evolution of structural mechanics and local drug elution. We systematically varied degree of radial expansion in model BVS constructs composed of poly dl-lactide-glycolide and generated in vitro metrics of device microstructure, degradation, erosion, mechanics and drug release. Experimental data permitted development of computational models that predicted transient concentrations of scaffold-derived soluble species and drug in the arterial wall, thus enabling speculation on the short- and long-term effects of differential expansion. We demonstrate that degree of expansion significantly affects scaffold properties critical to functionality, underscoring its relevance in BVS design and optimization. Bioresorbable vascular scaffold (BVS) therapy is beginning to transform the treatment of obstructive artery disease, owing to effective treatment of short term vessel closure while avoiding long term consequences such as in situ, late stent thrombosis - a fatal event associated with permanent implants such as drug-eluting stents. As device scaffolding and drug elution are temporary for BVS, the notion of using this therapy in lieu of existing, clinically approved devices seems attractive. However, there is still a limited understanding regarding the optimal lifetime and performance characteristics of erodible endovascular implants. Several engineering criteria must be met and clinical endpoints confirmed to ensure these devices are both safe and effective. In this manuscript, we sought to establish general principles for the design and deployment of erodible, drug-eluting endovascular scaffolds, with focus on how differential expansion can modulate device performance. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Use of Metallic Endosseous Implants as a Tooth Substitute.
1979-06-01
exposed in the oral cavity and placed in function with the opposing dentition iBACKGROUND The development of a dental implant that will serve as a...contract year was spent in testing the dental implant as a single tooth replacement. The ultimate goal of this implant study was to develop a free-standing...to read and sign an informed consent form. SURGICAL PROCEDURES The dental implant was inserted into the edentulous area using the exact procedures as
Brägger, U; Aeschlimann, S; Bürgin, W; Hämmerle, C H; Lang, N P
2001-02-01
The aim of this study was to compare the frequency of biological and technical complications with fixed partial dentures (FPDs) on implants, teeth and as mixed tooth-implant supported FPDs over 4 to 5 years of function. All implants belonged to the ITI Dental Implant System. Group I-I (implant FPD) included 33 patients with 40 FPDs, group T-T (tooth FPDs) 40 patients with 58 FPDs, group I-T (mixed tooth-implant FPDs) 15 with 18 FPD. Of the bridge abutments 144 were teeth and 105 were implants. The median number of units replaced by the FPDs was 3 (range 2-14). The mean age of the patients was 55.7 years (range 23-83). Complete failures resulted in the loss of one FPD in each group. Two implants were lost due to fracture secondarily to development of a bone defect. One tooth had a vertical fracture and 1 tooth was lost due to periodontitis. Biological complications (peri-implantitis, PPD > or = 5 mm and BOP+) occurred at 9.6% (10) of the implants. This number was, however, reduced to 5% if the threshold for definition of peri-implantitis was set at PPD > or = 6 mm and BOP+. Biological complications occurred in 11.8% (17) of the abutment teeth (NS compared to implants); 2.8% (4) had secondary caries, 4.9% (7) endodontic problems and 4.1% (6) had periodontitis (PPD > or = 5 mm, BOP+). Ten out of 32 patients with a general health problem indicated a biological complication, whereas 9 out of 53 patients with no general health problem had a biological complication (chi 2: NS). Statistically significantly more technical complications were found in FPDs on implants (chi 2, P < or = 0.05). The technical complications were associated with bruxism. Out of 10 bruxers 6 had a technical complication whereas 13 out of 75 non-bruxers had such a complication (chi 2 < or = 0.01). Extensions were associated with more technical complications (13 out of 35 with extensions versus 9 out of 81 without). In conclusion, favourable clinical conditions were found at tooth and implant abutments after 4-5 years of function. Loss of FPD over 4-5 years occurred at a similar rate with mixed, implant or tooth supported reconstructions. Significantly more porcelain fractures were found in FPDs on implants. Impaired general health status was not significantly associated with more biological failures but bruxism as well as extensions were associated with more technical failures.
Ertugay, Serkan; Kemal, Hatice S; Kahraman, Umit; Engin, Catagay; Nalbantgil, Sanem; Yagdi, Tahir; Ozbaran, Mustafa
2017-07-01
Significant mitral regurgitation (MR) is thought to decrease after left ventricular assist device (LVAD) implantation, and therefore repair of mitral valve is not indicated in current practice. However, residual moderate and severe MR leads to pulmonary artery pressure increase, thereby resulting in right ventricular (RV) dysfunction during follow-up. We examined the impact of residual MR on systolic function of the right ventricle by echocardiography after LVAD implantation. This study included 90 patients (mean age: 51.7 ± 10.9 years, 14.4% female) who underwent LVAD implantation (HeartMate II = 21, HeartWare = 69) in a single center between December 2010 and June 2014. Echocardiograms obtained at 3-6 months and over after implantation were analyzed retrospectively. RV systolic function was graded as normal, mild, moderate, and severely depressed. MR (≥moderate) was observed in 43 and 44% of patients at early and late period, respectively. Systolic function of the RV was severely depressed in 16 and 9% of all patients. Initial analysis (mean duration of support 174.3 ± 42.5 days) showed a statistically significant correlation between less MR and improved systolic function of RV (P = 0.01). Secondary echocardiographic analysis (following a mean duration of support of 435.1 ± 203 days) was also statistically significant for MR degree and RV systolic dysfunction (P = 0.008). Residual MR after LVAD implantation may cause deterioration of RV systolic function and cause right-sided heart failure symptoms. Repair of severe MR, in selected patients such as those with severe pulmonary hypertension and depressed RV, may be considered to improve the patient's clinical course during pump support. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Short-term risk of falling after cochlear implantation.
Stevens, Madelyn N; Baudhuin, Jacqueline E; Hullar, Timothy E
2014-01-01
Cochlear implantation is a highly effective intervention for hearing loss, but insertion of an implant into the cochlea is often accompanied by loss of residual hearing function. Sometimes, postoperative testing also shows loss of function in the semicircular canals or otolith organs. The effect of this loss on equilibrium, particularly in the short term following surgery, and the risk of falling due to this loss is unknown. We prospectively measured balance in 16 consecutive adult cochlear implant patients before and 2 weeks after surgery. Subjects stood on a foam pad with eyes closed, feet together and arms at the side. The length of time over which this posture could be maintained was recorded up to a maximum value of 30 s indicating normal performance. Ten of 16 subjects reached a maximal time on preoperative testing. Nine of 16 subjects lost balance function after surgery. Four of the 10 subjects with normal preoperative balance function lost function. Subjects older than the age of 60 were more likely to lose balance function than younger subjects. We used previously published values relating balance performance on foam to risk of falling to calculate the fall risk among our subjects. The relative risk of falling increased after surgery by more than threefold in some patients. Imbalance after cochlear implantation may be much more common, particularly in the short term, than previously appreciated. This imbalance is accompanied by an increased risk of falling in many patients. Careful preoperative counseling before implantation and postoperative therapeutic intervention to improve comfort and reduce the chance of falling may be warranted, particularly in patients at a risk for injuries from falls (level of evidence: 2b). © 2014 S. Karger AG, Basel.
Positron Lifetime Study on the As-Prepared Cd-Doped Pb-1212 Superconductive Oxides
NASA Astrophysics Data System (ADS)
Zhou, X. Y.; Zhou, X. Y.; Zhao, W. C.; Jin, H.; Cao, L. Z.; Zhai, L. H.; Han, R. D.
1997-12-01
The positron lifetime as a function of the Cd content x was measured for the as-prepared samples of (Pb1 - xCdx)Sr2(Y0.5Ca0.5)Cu2Oy. A constant long-lived lifetime was observed for all samples. The intensity of the long-lived lifetimes has an obvious decrease starting at x = 0.3 and indicated the existence of an impurity phase in the sample with x = 0.3. The monotonous decrease of the bulk lifetime for the single-phase samples implies that Cd mainly substitutes for Pb. The changes of the microstructure with Cd content were discussed.
Pacemakers and implantable cardioverter defibrillators--general and anesthetic considerations.
Rapsang, Amy G; Bhattacharyya, Prithwis
2014-01-01
A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia), special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
NASA Technical Reports Server (NTRS)
Neudeck, Philip G.
1998-01-01
Minority carrier lifetimes in epitaxial 4H-SiC p(+)-n junction diodes were measured via an analysis of reverse recovery switching characteristics. Behavior of reverse recovery storage time (t(s)) as a function of initial ON-state forward current (I(F)) and OFF-state reverse current (I(R)) followed well-documented trends which have been observed for decades in silicon p-n rectifiers. Average minority carrier (hole) lifetimes (tau(p)) calculated from plots of t(s) vs I(R)/I(F) strongly decreased with decreasing device area. Bulk and perimeter components of average hole lifetimes were separated by plotting 1/tau(p) as a function of device perimeter-to- area ratio (P/A). This plot reveals that perimeter recombination is dominant in these devices, whose areas are all less than 1 sq mm. The bulk minority carrier (hole) lifetime extracted from the 1/tau(p) vs P/A plot is approximately 0.7 micro-s, well above the 60 ns to 300 ns average iit'eptimes obtained when perimeter recombination effects are ignored in the analysis. Given the fact that there has been little previous investigation of bipolar diode and transistor performance as a function of perimeter-to-area ratio, this work raises the possibility that perimeter recombination may be partly responsible for poor effective minority carrier lifetimes and limited performance obtained in many previous SiC bipolar junction devices.
Flow in prosthetic heart valves: state-of-the-art and future directions.
Yoganathan, Ajit P; Chandran, K B; Sotiropoulos, Fotis
2005-12-01
Since the first successful implantation of a prosthetic heart valve four decades ago, over 50 different designs have been developed including both mechanical and bioprosthetic valves. Today, the most widely implanted design is the mechanical bileaflet, with over 170,000 implants worldwide each year. Several different mechanical valves are currently available and many of them have good bulk forward flow hemodynamics, with lower transvalvular pressure drops, larger effective orifice areas, and fewer regions of forward flow stasis than their earlier-generation counterparts such as the ball-and-cage and tilting-disc valves. However, mechanical valve implants suffer from complications resulting from thrombus deposition and patients implanted with these valves need to be under long-term anti-coagulant therapy. In general, blood thinners are not needed with bioprosthetic implants, but tissue valves suffer from structural failure with, an average life-time of 10-12 years, before replacement is needed. Flow-induced stresses on the formed elements in blood have been implicated in thrombus initiation within the mechanical valve prostheses. Regions of stress concentration on the leaflets during the complex motion of the leaflets have been implicated with structural failure of the leaflets with bioprosthetic valves. In vivo and in vitro experimental studies have yielded valuable information on the relationship between hemodynamic stresses and the problems associated with the implants. More recently, Computational Fluid Dynamics (CFD) has emerged as a promising tool, which, alongside experimentation, can yield insights of unprecedented detail into the hemodynamics of prosthetic heart valves. For CFD to realize its full potential, however, it must rely on numerical techniques that can handle the enormous geometrical complexities of prosthetic devices with spatial and temporal resolution sufficiently high to accurately capture all hemodynamically relevant scales of motion. Such algorithms do not exist today and their development should be a major research priority. For CFD to further gain the confidence of valve designers and medical practitioners it must also undergo comprehensive validation with experimental data. Such validation requires the use of high-resolution flow measuring tools and techniques and the integration of experimental studies with CFD modeling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayedh, H. M.; Svensson, B. G.; Hallén, A.
The carbon vacancy (V{sub C}) is a prevailing point defect in high-purity 4H-SiC epitaxial layers, and it plays a decisive role in controlling the charge carrier lifetime. One concept of reducing the V{sub C}-concentration is based on carbon self-ion implantation in a near surface layer followed by thermal annealing. This leads to injection of carbon interstitials (C{sub i}'s) and annihilation of V{sub C}'s in the epi-layer “bulk”. Here, we show that the excess of C atoms introduced by the self-ion implantation plays a negligible role in the V{sub C} annihilation. Actually, employing normalized implantation conditions with respect to displaced Cmore » atoms, other heavier ions like Al and Si are found to be more efficient in annihilating V{sub C}'s. Concentrations of V{sub C} below ∼2 × 10{sup 11} cm{sup −3} can be reached already after annealing at 1400 °C, as monitored by deep-level transient spectroscopy. This corresponds to a reduction in the V{sub C}-concentration by about a factor of 40 relative to the as-grown state of the epi-layers studied. The negligible role of the implanted species itself can be understood from simulation results showing that the concentration of displaced C atoms exceeds the concentration of implanted species by two to three orders of magnitude. The higher efficiency for Al and Si ions is attributed to the generation of collision cascades with a sufficiently high energy density to promote C{sub i}-clustering and reduce dynamic defect annealing. These C{sub i}-related clusters will subsequently dissolve during the post-implant annealing giving rise to enhanced C{sub i} injection. However, at annealing temperatures above 1500 °C, thermodynamic equilibrium conditions start to apply for the V{sub C}-concentration, which limit the net effect of the C{sub i} injection, and a competition between the two processes occurs.« less
A New Lifetime Distribution with Bathtube and Unimodal Hazard Function
NASA Astrophysics Data System (ADS)
Barriga, Gladys D. C.; Louzada-Neto, Francisco; Cancho, Vicente G.
2008-11-01
In this paper we propose a new lifetime distribution which accommodate bathtub-shaped, unimodal, increasing and decreasing hazard function. Some special particular cases are derived, including the standard Weibull distribution. Maximum likelihood estimation is considered for estimate the tree parameters present in the model. The methodology is illustrated in a real data set on industrial devices on a lite test.
Liquid metal ion source and alloy
Clark, Jr., William M.; Utlaut, Mark W.; Behrens, Robert G.; Szklarz, Eugene G.; Storms, Edmund K.; Santandrea, Robert P.; Swanson, Lynwood W.
1988-10-04
A liquid metal ion source and alloy, wherein the species to be emitted from the ion source is contained in a congruently vaporizing alloy. In one embodiment, the liquid metal ion source acts as a source of arsenic, and in a source alloy the arsenic is combined with palladium, preferably in a liquid alloy having a range of compositions from about 24 to about 33 atomic percent arsenic. Such an alloy may be readily prepared by a combustion synthesis technique. Liquid metal ion sources thus prepared produce arsenic ions for implantation, have long lifetimes, and are highly stable in operation.
Peter, Burghard
Immediate loading has proven to be a predictable modality for restorations with titanium dental implants. An increasing number of articles indicate that zirconia implants might osseointegrate to a similar extent in this context. This 5-year case report describes an outpatient maxillary restoration with eight immediately loaded zirconia implants. Implantation followed extensive bone augmentation. At the 5-year follow-up, all implants were still well osseointegrated clinically and radiologically. No major bone loss or peri-implantitis had occurred in spite of temporary insufficient patient compliance. More research and studies are needed to confirm these results.
Agata, Hideki; Sándor, George K.; Haimi, Suvi
2011-01-01
ABSTRACT Objectives The aim of this study was to compare microbiological, histological, and mechanical findings from tissues around osseointergrated dental implants in patients who had undergone tumour resection and subsequent bone grafting with non bone grafted patients without a history of oral cancer and to develop an effective tool for the monitoring of the peri-implant tissues. A third aim was to assess and compare the masticatory function of the two patient groups after reconstruction with dental implants. Material and Methods A total of 20 patients were divided into 2 groups. The first group was edentulous and treated with dental implants without the need for bone grafting. The second edentulous group, with a history of oral cancer involving the mandible, received onlay bone grafts with concurrent placement of dental implants. Microbiological, histological, mechanical and biochemical assessment methods, crevicular fluid flow rate, hygiene-index, implant mobility, and the masticatory function were analysed and compared in both patient groups. Results The microbiological examinations showed no evidence of the three most common pathogenic bacteria: Porphyromonas gingivalis, Prevotella intermedius, Actinobacillus actinomycetencomitans. A causal relationship between specific microbes and peri-implant inflammation could not be found. All biopsies in both patient groups revealed early signs of soft tissue peri-implant inflammation. Conclusions The crevicular fluid volume and grade of gingival inflammation around the dental implants were related. Peri-implant tissue findings were similar in the two patient groups despite the history of oral cancer and the need for bone grafting at the time of dental implant placement. PMID:24421999
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shin, Chang Seouk; School of Mechanical Engineering, Pusan National University, Pusan 609-735; Lee, Byoung-Seob
2016-02-15
The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1–10 mm{sup 2}. The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation withmore » an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research.« less
Carlsson, Gunnar E
2014-08-01
To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results.
2014-01-01
PURPOSE To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. MATERIALS AND METHODS Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. RESULTS Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. CONCLUSION In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results. PMID:25177466
Occlusal contact of fixed implant prostheses using functional bite impression technique.
Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro
2015-02-01
Functional bite impression (FBI) has been described as a definitive impression made under occlusal force after functional generated path (FGP) recording. This study compared the accuracy of occlusal contact of implant-fixed prostheses using the FBI technique and the conventional impression technique. Twelve subjects, each missing a single premolar or molar, were selected for this study. The conditions of the occlusal contacts were identified by the modified transillumination method. The occlusal contact condition was determined by comparing the rate of change in the occlusal contact area of the implant-fixed prostheses and both adjacent teeth before and after occlusal adjustment. The rate of change in the occlusal contact area using the FBI technique was 96%, and the rate using the conventional technique was 54%. The occlusal contact of implant prostheses using the FBI technique revealed better accuracy than that of the conventional technique. Regarding the FBI technique, a precise and functional prosthesis could be produced by completing the maxillomandibular registration, impression, and FGP at the same time.
NASA Astrophysics Data System (ADS)
Kato, Kentaro; Matsuki, Hidetoshi; Sato, Fumihiro; Satoh, Tadakuni; Handa, Nobuyasu
2009-04-01
Functional electrical stimulation (FES) is the therapy used for the rehabilitation of lost movement function by applying electrical stimulation (ES) to paralyzed extremities. To realize ES, we adapted the implanted direct feeding method (DFM). In this method, small implanted stimulators are placed under the skin at a depth of 10-20 mm and stimulus energy and signals for controlling devices are applied to them by a mounted system using magnetic coupling. This method has the merits of having no percutaneous points and high-precision stimulation. However, since the mounted system and implanted elements are separated, it is necessary to add feedback information from inside the body to confirm the system operation for safety therapy or to rehabilitate motor function smoothly. Satisfying both restrictions, we propose the magnetic connective dual resonance (MCDR) antenna, which has two resonance circuits. Adding the LC serial circuit to the LC parallel circuit gives the sending function. In this paper, we report the principle of the MCDR antenna and verify its duplex communication ability through communication experiment. This antenna enables DFM of FES to rehabilitate more complex movements.
Hollow fibers - Their applications to the study of mammalian cell function
NASA Technical Reports Server (NTRS)
Hymer, W. C.; Angeline, M.; Harkness, J.; Chu, M.; Grindleland, R.
1984-01-01
The use of hollow fiber technology in cell culture and transplantation is examined. The morphologies of encapsulated pituitary cells before and after implantation into the rat are defined. Implantation experiments using hollow fibers to study mammalian cell functions are described. Consideration is given to examining somatotroph, prolactin, prostrate, fibroblast, and retinal cell functions. These experiments demonstrate that hollow fiber technology is applicable for studying mammalian cell functions.
Laurito, Domenica; Lamazza, Luca; Spink, Michael J.; De Biase, Alberto
2012-01-01
Summary Aims The success of maxillary and mandibular tissue supported implant prostheses varies in the literature, and the ideal protocol may be elusive from given the numerous studies. The oral rehabilitation option is an alternative to conventional dentures and should improve function, satisfaction, and retention. The purpose of this review article is to clarify these questions. Methods The search of literature reviews English non-anecdotal implant overdentures articles from 1991 to 2011. Results The results display an aggregate comprehensive list of categorical variables from the literature review. Overall success of maxillary and mandibular implant overdenture was respectively, 86.6% and 95.8%. Conclusion The literature indicates that the implant overdenture prosthesis provides predictable results – enhanced stability, function and a high-degree of satisfaction compared to conventional removable dentures. PMID:22783448
Apostolopoulos, Peter; Darby, Ivan
2017-04-01
Ridge preservation is any procedure that takes place at the time of, or shortly after an extraction, to minimise resorption of the ridge and maximise bone formation within the socket. The aim of this project is to investigate the outcome of implant treatment following ridge preservation and compare it to an ungrafted implant control group. Following ethics approval, an electronic and manual search of patient records was conducted, and appropriate cases of implant placement following a ridge preservation procedure were identified. Forty-two patients with 51 implants at ridge-preserved sites were examined by one author (PA) with the following parameters assessed at each implant: pocket probing depth, bleeding on probing, presence/absence of plaque and radiographic bone loss. Clinical and radiographic findings were compared to an ungrafted implant control group and analysed by years in function. There was a 100% survival rate of implants in ridge-preserved sites. In the majority of cases, ridge preservation was performed in the anterior maxilla with a flap raised and the use of deproteinised bovine bone mineral and collagen membrane materials. The mean time in function was 31 (±24) months with a range of 2-102 months. Differences in the mean PPD, BOP, plaque index and radiographic bone loss were not statistically significant between implants at ridge-preserved or ungrafted sites. The overall success rate was around 58% for ungrafted implants and around 51% for implants in ridge-preserved sites. However, this difference was not statistically significant. In this retrospective study, implant placement at ridge-preserved sites was a predictable procedure that led to very high survival rates and similar success rates to implant placement at ungrafted sites. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Block, Andrew R; Marek, Ryan J; Ben-Porath, Yossef S; Kukal, Deborah
2017-01-01
Spinal cord stimulation (SCS) has variable effectiveness in controlling chronic pain. Previous research has demonstrated that psychosocial factors are associated with diminished results of SCS. The objective of this investigation is to examine associations between pre-implant psychological functioning as measured by the Minnesota Multiphasic Personality Inventory-2-Restructured Form (MMPI-2-RF) and SCS outcomes. SCS candidates at two sites (total N = 319) completed the MMPI-2-RF and measures of pain, emotional distress, and functional ability as part of a pre-implant psychological evaluation. At an average of 5 months post-implant, patients completed the measures of pain and emotional distress a second time. Poorer SCS outcomes and poorer patient satisfaction were associated with higher pre-implant MMPI-2-RF scores on scales used to assess emotional dysfunction, somatic/cognitive complaints, and interpersonal problems. Ways through which pre-implant psychological evaluations of spinal cord stimulator candidates can be informed by MMPI-2-RF findings are discussed. © The Author(s) 2015.
Optimum gradient material for a functionally graded dental implant using metaheuristic algorithms.
Sadollah, Ali; Bahreininejad, Ardeshir
2011-10-01
Despite dental implantation being a great success, one of the key issues facing it is a mismatch of mechanical properties between engineered and native biomaterials, which makes osseointegration and bone remodeling problematical. Functionally graded material (FGM) has been proposed as a potential upgrade to some conventional implant materials such as titanium for selection in prosthetic dentistry. The idea of an FGM dental implant is that the property would vary in a certain pattern to match the biomechanical characteristics required at different regions in the hosting bone. However, matching the properties does not necessarily guarantee the best osseointegration and bone remodeling. Little existing research has been reported on developing an optimal design of an FGM dental implant for promoting long-term success. Based upon remodeling results, metaheuristic algorithms such as the genetic algorithms (GAs) and simulated annealing (SA) have been adopted to develop a multi-objective optimal design for FGM implantation design. The results are compared with those in literature. Copyright © 2011 Elsevier Ltd. All rights reserved.
Capacitive Feedthroughs for Medical Implants
Grob, Sven; Tass, Peter A.; Hauptmann, Christian
2016-01-01
Important technological advances in the last decades paved the road to a great success story for electrically stimulating medical implants, including cochlear implants or implants for deep brain stimulation. However, there are still many challenges in reducing side effects and improving functionality and comfort for the patient. Two of the main challenges are the wish for smaller implants on one hand, and the demand for more stimulation channels on the other hand. But these two aims lead to a conflict of interests. This paper presents a novel design for an electrical feedthrough, the so called capacitive feedthrough, which allows both reducing the size, and increasing the number of included channels. Capacitive feedthroughs combine the functionality of a coupling capacitor and an electrical feedthrough within one and the same structure. The paper also discusses the progress and the challenges of the first produced demonstrators. The concept bears a high potential in improving current feedthrough technology, and could be applied on all kinds of electrical medical implants, even if its implementation might be challenging. PMID:27660602
Capacitive Feedthroughs for Medical Implants.
Grob, Sven; Tass, Peter A; Hauptmann, Christian
2016-01-01
Important technological advances in the last decades paved the road to a great success story for electrically stimulating medical implants, including cochlear implants or implants for deep brain stimulation. However, there are still many challenges in reducing side effects and improving functionality and comfort for the patient. Two of the main challenges are the wish for smaller implants on one hand, and the demand for more stimulation channels on the other hand. But these two aims lead to a conflict of interests. This paper presents a novel design for an electrical feedthrough, the so called capacitive feedthrough, which allows both reducing the size, and increasing the number of included channels. Capacitive feedthroughs combine the functionality of a coupling capacitor and an electrical feedthrough within one and the same structure. The paper also discusses the progress and the challenges of the first produced demonstrators. The concept bears a high potential in improving current feedthrough technology, and could be applied on all kinds of electrical medical implants, even if its implementation might be challenging.
Fabrication of fixed implant prostheses using function bite impression technique (FBI technique).
Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro; Kurtz, Kenneth S
2012-10-01
The patient was partially edentulous, lacking both the first mandibular molars. The FBI and the conventional impression technique were used for the fabrication of implant-fixed prosthesis replacing the right and left molars, respectively. In the FBI technique, the definitive impression was made under occlusal force and functionally generated path (FGP) recording at the same time. The right and left occlusal contact areas were compared after completing the implant-fixed prosthesis rehabilitation. It has been suggested that accuracy of the impression and maxillomandibular registration is necessary to ensure a satisfactory long-term clinical outcome. The transfer of the exact position of the implants to the working cast is even more important because implants lack the mobility of natural teeth. There are displacement differences between implants and natural teeth under occlusal force. The FBI technique may compensate for this difference in accuracy. Using the FBI technique, a precise prosthesis could be produced by completing simultaneously the maxillomandibular registration, impression and FGP. Copyright © 2012 Japan Prosthodontic Society. All rights reserved.
Prosthetic management of malpositioned implant using custom cast abutment
Chatterjee, Aishwarya; Ragher, Mallikarjuna; Patil, Sanket; Chatterjee, Debopriya; Dandekeri, Savita; Prabhu, Vishnu
2015-01-01
Two cases are reported with malpositioned implants. Both the implants were placed 6–7 months back. They had osseointegrated well with the surrounding bone. However, they presented severe facial inclination. Case I was restored with custom cast abutment with an auto polymerizing acrylic gingival veneer. Case II was restored with custom cast UCLA type plastic implant abutment. Ceramic was directly fired on the custom cast abutments. The dual treatment strategy resulted in functional and esthetic restorations despite facial malposition of the implants. PMID:26538957
Current trends in dental implants
Gaviria, Laura; Salcido, John Paul; Guda, Teja
2014-01-01
Tooth loss is very a very common problem; therefore, the use of dental implants is also a common practice. Although research on dental implant designs, materials and techniques has increased in the past few years and is expected to expand in the future, there is still a lot of work involved in the use of better biomaterials, implant design, surface modification and functionalization of surfaces to improve the long-term outcomes of the treatment. This paper provides a brief history and evolution of dental implants. It also describes the types of implants that have been developed, and the parameters that are presently used in the design of dental implants. Finally, it describes the trends that are employed to improve dental implant surfaces, and current technologies used for the analysis and design of the implants. PMID:24868501
Lei, Rong; Jiang, Hongshan; Hu, Fan; Yan, Jin; Zhu, Shuifang
2017-02-01
Leaf chlorosis induced by plant virus infection has a short fluorescence lifetime, which reflects damaged photosynthetic complexes and degraded chloroplasts. Plant viruses often induce chlorosis and necrosis, which are intimately related to photosynthetic functions. Chlorophyll fluorescence lifetime measurement is a valuable noninvasive tool for analyzing photosynthetic processes and is a sensitive indicator of the environment surrounding the fluorescent molecules. In this study, our central goal was to explore the effect of viral infection on photosynthesis by employing chlorophyll fluorescence lifetime imaging (FLIM), steady-state fluorescence, non-photochemical quenching (NPQ), transmission electron microscopy (TEM), and pigment analysis. The data indicated that the chlorophyll fluorescence lifetime of chlorotic leaves was significantly shorter than that of healthy control leaves, and the fitted short lifetime component of chlorophyll fluorescence of chlorotic leaves was dominant. This dominant short lifetime component may result from damage to the structure of thylakoid, which was confirmed by TEM. The NPQ value of chlorotic leaves was slightly higher than that of healthy green leaves, which can be explained by increased neoxanthin, lutein and violaxanthin content relative to chlorophyll a. The difference in NPQ is slight, but FLIM can provide simple and direct characterization of PSII structure and photosynthetic function. Therefore, this technique shows great potential as a simple and rapid method for studying mechanisms of plant virus infection.
A new method for measuring the neutron lifetime using an in situ neutron detector
Morris, Christopher L.; Adamek, Evan Robert; Broussard, Leah Jacklyn; ...
2017-05-30
Here, we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons (UCN), which provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We also used an active detector that can be lowered into the trap to measure the neutron distribution as a function of height and measure the influence of marginally trapped UCN on the neutron lifetime measurement. Additionally, measurements have demonstrated phase-space evolution and its effect on the lifetime measurement.
A new method for measuring the neutron lifetime using an in situ neutron detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morris, Christopher L.; Adamek, Evan Robert; Broussard, Leah Jacklyn
Here, we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons (UCN), which provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We also used an active detector that can be lowered into the trap to measure the neutron distribution as a function of height and measure the influence of marginally trapped UCN on the neutron lifetime measurement. Additionally, measurements have demonstrated phase-space evolution and its effect on the lifetime measurement.
Maxillary implant-retained partial overdenture with Dolder bar attachment: a clinical report.
Kim, Hyeongil; Buhite, Robert J; Monaco, Edward A
2015-03-01
This article describes a technique for maintaining a maxillary Kennedy III partial removable dental prosthesis design in a patient who had non-restorable failing abutments by replacing the abutments with dental implants. Two implants were placed immediately after extraction of the abutment teeth in the anterior maxilla. After the implants were fully integrated, a Dolder bar attachment was fitted onto the implants. A new maxillary partial removable dental prosthesis was fabricated using the implants and the remaining natural teeth as abutments to restore function and esthetics. With the aid of dental implants, this Kennedy III maxillary removable dental prosthesis design could provide additional retention and support by promoting cross-arch stability and tissue, implant and tooth support. The patient's satisfaction was significantly increased.
Aulakh, Tajeshwar S; Jayasekera, Narlaka; Singh, Rohit; Patel, Amit; Roulahamin, Nick; Kuiper, Jan H; Richardson, James B
2015-06-01
Metal-on-metal hip resurfacing is undertaken worldwide. This procedure helps preserve femoral bone stock and allows patients to return to high activity sports. Most outcome studies are individual surgeon case series from single centers where the results and outcomes are evaluated by the same surgeon. One method of increasing the external validity of a follow-up study is to have a multi-centre study design with independent assessment of the outcomes. We present an independent assessment of eleven year follow-up of hip resurfacing outcomes from an international hip resurfacing register. The purpose of this study was to assess: Implant survival at maximum follow-up for revision due to any reason, implant survival at maximum follow-up for revision due to major causes of failure, hip function following hip resurfacing and factors affecting hip function, effect of gender and age on hip function and implant survival, effect of femoral component size on hip function and implant survival. 4535 patients (5000 hips) entered into the registry during 1997-2002 were studied. In summary, at a maximum follow-up of 11 years hip resurfacing has a good implant survival of 96.2% and excellent post-operative function. This is excellent given the international and multisurgeon nature of this cohort where majority of the surgeons were in their learning curve.
GARGARI, M.; PRETE, V.; PUJIA, M.; CERUSO, F. M.
2013-01-01
SUMMARY Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year. Objective The aim of this study is to compare functional efficiency and patients satisfaction between tooth-supported and implant-supported overdenture through a questionnaire that accurately reflects the real concerns of patients with dental prosthesis. Methods Forty-three patients were selected from the out patient clinic, Department of Dentistry “Fra G.B. Orsenigo Ospedale San Pietro F.B.F.”, Rome, Italy. Their age were ranging from 61 to 83 years. Eighteen patients were rehabilitated with overdentures supported by natural teeth and twenty-five with overdentures implant-supported. Discussion and Result The questionnaire proposed one year after the insertion of the prosthetis has showed that there isn’t difference statistically significant in terms of function, phonetics and aesthetics between overdenture implant-supported and tooth-supported. Conclusions The results of the questionnaire showed that the patients generally had a high level of satisfaction concern to the masticatory function, esthetics and phonetics. In addition, on average, they haven’t difficulty in removal and insertion of the denture and in oral hygiene. They haven’t in both groups problems related to fractures. PMID:23741602
Gargari, M; Prete, V; Pujia, M; Ceruso, F M
2012-10-01
Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year. The aim of this study is to compare functional efficiency and patients satisfaction between tooth-supported and implant-supported overdenture through a questionnaire that accurately reflects the real concerns of patients with dental prosthesis. Forty-three patients were selected from the out patient clinic, Department of Dentistry "Fra G.B. Orsenigo Ospedale San Pietro F.B.F.", Rome, Italy. Their age were ranging from 61 to 83 years. Eighteen patients were rehabilitated with overdentures supported by natural teeth and twenty-five with overdentures implant-supported. DISCUSSION AND RESULT: The questionnaire proposed one year after the insertion of the prosthetis has showed that there isn't difference statistically significant in terms of function, phonetics and aesthetics between overdenture implant-supported and tooth-supported. The results of the questionnaire showed that the patients generally had a high level of satisfaction concern to the masticatory function, esthetics and phonetics. In addition, on average, they haven't difficulty in removal and insertion of the denture and in oral hygiene. They haven't in both groups problems related to fractures.
An open circuit voltage decay system for performing injection dependent lifetime spectroscopy
NASA Astrophysics Data System (ADS)
Lacouture, Shelby; Schrock, James; Hirsch, Emily; Bayne, Stephen; O'Brien, Heather; Ogunniyi, Aderinto A.
2017-09-01
Of all of the material parameters associated with a semiconductor, the carrier lifetime is by far the most complex and dynamic, being a function of the dominant recombination mechanism, the equilibrium number of carriers, the perturbations in carriers (e.g., carrier injection), and the temperature, to name the most prominent variables. The carrier lifetime is one of the most important parameters in bipolar devices, greatly affecting conductivity modulation, on-state voltage, and reverse recovery. Carrier lifetime is also a useful metric for device fabrication process control and material quality. As it is such a dynamic quantity, carrier lifetime cannot be quoted in a general range such as mobility; it must be measured. The following describes a stand-alone, wide-injection range open circuit voltage decay system with unique lifetime extraction algorithms. The system is initially used along with various lifetime spectroscopy techniques to extract fundamental recombination parameters from a commercial high-voltage PIN diode.
Nagel, Thomas; Kelly, Daniel J
2013-04-01
The biomechanical functionality of articular cartilage is derived from both its biochemical composition and the architecture of the collagen network. Failure to replicate this normal Benninghoff architecture in regenerating articular cartilage may in turn predispose the tissue to failure. In this article, the influence of the maturity (or functionality) of a tissue-engineered construct at the time of implantation into a tibial chondral defect on the likelihood of recapitulating a normal Benninghoff architecture was investigated using a computational model featuring a collagen remodeling algorithm. Such a normal tissue architecture was predicted to form in the intact tibial plateau due to the interplay between the depth-dependent extracellular matrix properties, foremost swelling pressures, and external mechanical loading. In the presence of even small empty defects in the articular surface, the collagen architecture in the surrounding cartilage was predicted to deviate significantly from the native state, indicating a possible predisposition for osteoarthritic changes. These negative alterations were alleviated by the implantation of tissue-engineered cartilage, where a mature implant was predicted to result in the formation of a more native-like collagen architecture than immature implants. The results of this study highlight the importance of cartilage graft functionality to maintain and/or re-establish joint function and suggest that engineering a tissue with a native depth-dependent composition may facilitate the establishment of a normal Benninghoff collagen architecture after implantation into load-bearing defects.
Uterine biology in pigs and sheep
2012-01-01
There is a dialogue between the developing conceptus (embryo-fetus and associated placental membranes) and maternal uterus which must be established during the peri-implantation period for pregnancy recognition signaling, implantation, regulation of gene expression by uterine epithelial and stromal cells, placentation and exchange of nutrients and gases. The uterus provide a microenvironment in which molecules secreted by uterine epithelia or transported into the uterine lumen represent histotroph required for growth and development of the conceptus and receptivity of the uterus to implantation. Pregnancy recognition signaling mechanisms sustain the functional lifespan of the corpora lutea (CL) which produce progesterone, the hormone of pregnancy essential for uterine functions that support implantation and placentation required for a successful outcome of pregnancy. It is within the peri-implantation period that most embryonic deaths occur due to deficiencies attributed to uterine functions or failure of the conceptus to develop appropriately, signal pregnancy recognition and/or undergo implantation and placentation. With proper placentation, the fetal fluids and fetal membranes each have unique functions to ensure hematotrophic and histotrophic nutrition in support of growth and development of the fetus. The endocrine status of the pregnant female and her nutritional status are critical for successful establishment and maintenance of pregnancy. This review addresses the complexity of key mechanisms that are characteristic of successful reproduction in sheep and pigs and gaps in knowledge that must be the subject of research in order to enhance fertility and reproductive health of livestock species. PMID:22958877
Koca, Omer Lutfi; Eskitascioglu, Gurcan; Usumez, Aslihan
2005-01-01
Implants placed in the posterior maxilla have lower success rates compared to implants placed in other oral regions. Inadequate bone levels have been suggested as a reason for this differential success rate. The purpose of this study was to determine the amount and localization of functional stresses in implants and adjacent bone locations when the implants were placed in the posterior maxilla in proximity to the sinus using finite element analysis (FEA). A 3-dimensional finite element model of a maxillary posterior section of bone (Type 3) was used in this study. Different bony dimensions were generated to perform nonlinear calculations. A single-piece 4.1x10-mm screw-shaped dental implant system (ITI solid implant) was modeled and inserted into atrophic maxillary models with crestal bone heights of 4, 5, 7, 10, or 13 mm. In some models the implant penetrated the sinus floor. Cobalt-Chromium (Wiron 99) was used as the crown framework material placed onto the implant, and porcelain was used for occlusal surface of the crown. A total average occlusal force (vertical load) of 300 N was applied at the palatal cusp (150 N) and mesial fossa (150 N) of the crown. The implant and superstructure were simulated in finite element software (Pro/Engineer 2000i program). For the porcelain superstructure for bone levels, maximum von Mises stress values were observed on the mesial fossae and palatal cusp. For the bone structure, the maximum von Mises stress values were observed in the palatal cortical bone adjacent to the implant neck. There was no stress within the spongy bone. High stresses occurred within the implants for all bone levels. The maximum von Mises stresses in the implants were localized in the neck of implants for 4- and 5-mm bone levels, but for 7-, 10-, and 13-mm bone levels more even stresses occurred within the implants.
Crater function moments: Role of implanted noble gas atoms
NASA Astrophysics Data System (ADS)
Hobler, Gerhard; Maciążek, Dawid; Postawa, Zbigniew
2018-04-01
Spontaneous pattern formation by energetic ion beams is usually explained in terms of surface-curvature dependent sputtering and atom redistribution in the target. Recently, the effect of ion implantation on surface stability has been studied for nonvolatile ion species, but for the case of noble gas ion beams it has always been assumed that the implanted atoms can be neglected. In this work, we show by molecular dynamics (MD) and Monte Carlo (MC) simulations that this assumption is not valid in a wide range of implant conditions. Sequential-impact MD simulations are performed for 1-keV Ar, 2-keV Kr, and 2-keV Xe bombardments of Si, starting with a pure single-crystalline Si target and running impacts until sputtering equilibrium has been reached. The simulations demonstrate the importance of the implanted ions for crater-function estimates. The atomic volumes of Ar, Kr, and Xe in Si are found to be a factor of two larger than in the solid state. To extend the study to a wider range of energies, MC simulations are performed. We find that the role of the implanted ions increases with the ion energy although the increase is attenuated for the heavier ions. The analysis uses the crater function formalism specialized to the case of sputtering equilibrium.
Hayes, Galina; Gibson, Tom; Moens, Noel M M; Nykamp, Stephanie; Wood, Darren; Foster, Robert; Lerer, Asaf
2016-01-01
Gentamicin impregnated collagen sponge (GICS) can be used to treat intra-articular surgical site infections. High local concentrations of gentamicin can be reached for short periods; however the collagen vehicle may persist for much longer periods. We wished to determine the effect of sponge implantation on joint inflammation and renal function. Eighteen medium sized mixed breed research dogs of hound type were randomized to two groups; arthroscopic implantation of GICS at gentamicin dose = 6 mg/kg (n = 9) or sham operation (n = 9). Endpoints consisted of joint inflammation measured by synovial fluid cell counts and cytokine concentrations; lameness measured by force plate asymmetry indices; and renal function measured by glomerular filtration rate (GFR) study. The prevalence of lesions associated with aminoglycoside nephrotoxicity was assessed by renal biopsy and transmission electron microscopy. Gentamicin impregnated collagen sponge implantation caused joint inflammation (p <0.01), lameness (p = 0.04), and decreased GFR (p = 0.04). No difference was observed in the prevalence of renal lesions on biopsy between the treatment and control groups (p = 0.49). Gentamicin impregnated collagen sponge implantation causes joint inflammation and lameness as well as GFR reductions at the dose assessed. Gentamicin impregnated collagen sponge are not recommended for intra-articular implantation in dogs.
Jacobs, R; van Steenberghe, D
1991-01-01
To clarify more of the tactile function of oral implants, both an interocclusal thickness detection and discrimination task were carried out in 4 different test conditions on 37 patients: t (tooth)/t, i (implant)/t, i/i and d (denture)/o (overdenture supported by implants). For the interocclusal detection of steel foils, the 50% detection threshold level (RL) in the 4 conditions was 20, 48, 64 and 108 microns, respectively, which indicates significant differences. The ability to discriminate interdental thickness differences was tested with a 0.2 and 1.0 mm standard. It was evaluated as the 75% discrimination level (DL). In the 0.2 mm discrimination task, corresponding DL-values for the t/t, i/t, i/i and d/o condition were 25, 55, 66 and 134 microns, whereas the 1.0 mm standard gave values of 193, 293, 336 and 348 microns, respectively. All results differed significantly from each other (p less than 0.05) except for the i/i-d/o comparison of the 1.0 mm discrimination task where the difference was negligible. The present findings indicate that the tactile sensibility of implants is reduced with regard to natural teeth. Remaining receptors of the peri-implant tissues might play a compensatory role in the decreased exteroceptive function.
The clavicle hook plate for Neer type II lateral clavicle fractures.
Renger, R J; Roukema, G R; Reurings, J C; Raams, P M; Font, J; Verleisdonk, E J M M
2009-09-01
To evaluate functional and radiologic outcome in patients with a Neer type II lateral clavicle fracture treated with the clavicle hook plate. Multicenter retrospective study. Five level I and II trauma centers. Forty-four patients, average age 38.4 years (18-66 years), with a Neer type II lateral clavicle fracture treated with the clavicle hook plate between January 1, 2003, and December 31, 2006. Open reduction and internal fixation with the clavicle hook plate. Removal of all 44 implants after consolidation at a mean of 8.4 months (2-33 months) postoperatively. At an average follow-up of 27.4 months (13-48 months), functional outcome was assessed with the Constant-Murley scoring system. Radiographs were taken to evaluate consolidation and to determine the distance between the coracoid process and the clavicle. The average Constant score was 92.4 (74-100). The average distance between the coracoid process and the clavicle was 9.8 mm (7.3-14.8 mm) compared with 9.4 mm (6.9-14.3 mm) on the contralateral nonoperative side. We observed 1 dislocation of an implant (2.2%), 2 cases of pseudarthrosis (4.5%), 2 superficial wound infections (4.5%), 2 patients with hypertrophic scar tissue (4.5%), and 3 times an acromial osteolysis (6.8%). Thirty patients (68%) reported discomfort due to the implant. These implant-related complaints and the acromial osteolysis disappeared after removal of the hook plate. With all the patients, direct functional aftercare was possible. The clavicle hook plate is a suitable implant for Neer type II clavicle fractures. The advantage of this osteosynthesis is the possibility of immediate functional aftercare. We observed a high percentage of discomfort due to the implant; therefore, we advise to remove the implant as soon as consolidation has taken place.
Hasin, Tal; Grupper, Avishay; Dillon, John J; Maleszewski, Joseph J; Li, Zhuo; Topilsky, Yan; Frantz, Robert P; Edwards, Brooks S; Pereira, Naveen L; Maltais, Simon; Stulak, John M; Joyce, Lyle; Daly, Richard; Park, Soon J; Kushwaha, Sudhir S
Renal function improves early after left ventricular assist device (LVAD) implantation but later decline has been observed. We sought to determine the occurrence and evaluate possible causes for this decline. In 62 consecutive patients with HeartMateII LVAD with available calculated glomerular filtration rate (GFR, ml/min/1.73 m) 1 year after implant, GFR was assessed repeatedly and possible predictors for decline from 3 to 12 months were investigated. Post-mortem renal specimens for patients supported with an LVAD were evaluated. GFR 54.5 ± 19.5 at admission increased to 66.4 ± 22.3 preoperatively and to 79.2 ± 30.1 ~1 month after implantation. Subsequently at ~3 months GFR declined to 74.7 ± 25.4, at ~6 months to 68.8 ± 23.1, and ~1 year after implant to 63.9 ± 17.7. Glomerular filtration rate at 1 year was significantly lower (p < 0.0001, p < 0.0001, p = 0.005) than GFR 1, 3, and 6 months after implant. Early rise in GFR after surgery was not associated with late decline. Shorter bypass time (β = -0.09, p = 0.048) and higher albumin 3 months after LVAD (β = 14.4, p = 0.025) were significantly associated with less later decline in GFR. Arteriosclerosis was identified in autopsy renal specimens. In conclusion, early gains in renal function after LVAD implant are not sustained in many patients. Patient, device, and operative factors may influence long-term renal function in these patients.
Increased osteoblast and decreased Staphylococcus epidermidis functions on nanophase ZnO and TiO2.
Colon, Gabriel; Ward, Brian C; Webster, Thomas J
2006-09-01
Many engineers and surgeons trace implant failure to poor osseointegration (or the bonding of an orthopedic implant to juxtaposed bone) and/or bacteria infection. By using novel nanotopographies, researchers have shown that nanostructured ceramics, carbon fibers, polymers, metals, and composites enhance osteoblast adhesion and calcium/phosphate mineral deposition. However, the function of bacteria on materials with nanostructured surfaces remains largely uninvestigated. This is despite the fact that during normal surgical insertion of an orthopedic implant, bacteria from the patient's own skin and/or mucosa enters the wound site. These bacteria (namely, Staphylococcus epidermidis) irreversibly adhere to an implant surface while various physiological stresses induce alterations in the bacterial growth rate leading to biofilm formation. Because of their integral role in determining the success of orthopedic implants, the objective of this in vitro study was to examine the functions of (i) S. epidermidis and (ii) osteoblasts (or bone-forming cells) on ZnO and titania (TiO(2)), which possess nanostructured compared to microstructured surface features. ZnO is a well-known antimicrobial agent and TiO(2) readily forms on titanium once implanted. Results of this study provided the first evidence of decreased S. epidermidis adhesion on ZnO and TiO(2) with nanostructured when compared with microstructured surface features. Moreover, compared with microphase formulations, results of this study showed increased osteoblast adhesion, alkaline phosphatase activity, and calcium mineral deposition on nanophase ZnO and TiO(2). In this manner, this study suggests that nanophase ZnO and TiO(2) may reduce S. epidermidis adhesion and increase osteoblast functions necessary to promote the efficacy of orthopedic implants.
Li, Tao; Zhang, Yongqiang; Shao, Bo; Gao, Yuan; Zhang, Chen; Cao, Qiang; Kong, Liang
2015-12-01
Dental implants have been widely used in the last few decades. However, patients with insufficient bone height need reconstructive surgeries before implant insertion. The distraction implant (DI) has been invented to simplify the treatment procedure, but the shortcomings of DIs have limited their clinical use. We incorporated biodegradable polyester into a novel DI called the partially biodegradable distraction implant (PBDI). The purpose of this study was to assess the radiological, histological, and biomechanical properties of the PBDI in animal models. PBDIs were manufactured and inserted into the atrophied mandibles of nine dogs. Box-shaped alveolar bones were segmented and distracted. The dogs were randomly divided into three groups that were sacrificed 1, 2, and 3 months after the implant insertion. Actual augmentation height (AAH) of the bone segments was measured to evaluate the effect of distraction. X-ray examination and micro-CT reconstruction and analysis were used to evaluate the regenerated bone in the distraction gap and bone around the functional element. Histological sections were used to evaluate the osseointegration and absorption of the PBDI. Fatigue tests were used to evaluate the biomechanical properties of the PBDI. Little change was found in AAH among the three groups. X-ray examination and micro-CT reconstruction showed good growth of regenerated bone in the distraction gap. Alveolar bone volume around the functional element increased steadily. No obvious bone absorption occurred in the alveolar crest around PBDI. Three months after distraction, the functional element achieved osseointegration, and the support element began to be absorbed. All PBDIs survived the fatigue test. The PBDI is a novel and reliable dental implant. It becomes a conventional implant after the absorption of the support element and the removal of the distraction screw. It is a promising replacement for conventional implants in patients with insufficient alveolar bone height. © 2014 Wiley Periodicals, Inc.
Urban, Istvan; Jovanovic, Sascha A; Buser, Daniel; Bornstein, Michael M
2015-01-01
The objective of this study was to assess implant therapy after a staged guided bone regeneration procedure in the anterior maxilla by lateralization of the nasopalatine nerve and vessel bundle. Neurosensory function following augmentative procedures and implant placement, assessed using a standardized questionnaire and clinical examination, were the primary outcome variables measured. This retrospective study included patients with a bone defect in the anterior maxilla in need of horizontal and/or vertical ridge augmentation prior to dental implant placement. The surgical sites were allowed to heal for at least 6 months before placement of dental implants. All patients received fixed implant-supported restorations and entered into a tightly scheduled maintenance program. In addition to the maintenance program, patients were recalled for a clinical examination and to fill out a questionnaire to assess any changes in the neurosensory function of the nasopalatine nerve at least 6 months after function. Twenty patients were included in the study from February 2001 to December 2010. They received a total of 51 implants after augmentation of the alveolar crest and lateralization of the nasopalatine nerve. The follow-up examination for questionnaire and neurosensory assessment was scheduled after a mean period of 4.18 years of function. None of the patients examined reported any pain, they did not have less or an altered sensation, and they did not experience a "foreign body" feeling in the area of surgery. Overall, 6 patients out of 20 (30%) showed palatal sensibility alterations of the soft tissues in the region of the maxillary canines and incisors resulting in a risk for a neurosensory change of 0.45 mucosal teeth regions per patient after ridge augmentation with lateralization of the nasopalatine nerve. Regeneration of bone defects in the anterior maxilla by horizontal and/or vertical ridge augmentation and lateralization of the nasopalatine nerve prior to dental implant placement is a predictable surgical technique. Whether or not there were clinically measurable impairments of neurosensory function, the patients did not report them or were not bothered by them.
Ya, Huiyuan; Chen, Qiufang; Wang, Weidong; Chen, Wanguang; Qin, Guangyong; Jiao, Zhen
2012-01-01
The stimulation effect that some beneficial agronomic qualities have exhibited in present-generation plants have also been observed due to ion implantation on plants. However, there is relatively little knowledge regarding the molecular mechanism of the stimulation effects of ion-beam implantation. In order to extend our current knowledge about the functional genes related to this stimulation effect, we have reported a comprehensive microarray analysis of the transcriptome features of the promoted-growth rice seedlings germinating from seeds implanted by a low-energy N+ beam. The results showed that 351 up-regulated transcripts and 470 down-regulated transcripts, including signaling proteins, kinases, plant hormones, transposable elements, transcription factors, non-coding protein RNA (including miRNA), secondary metabolites, resistance proteins, peroxidase and chromatin modification, are all involved in the stimulating effects of ion-beam implantation. The divergences of the functional catalog between the vacuum and ion implantation suggest that ion implantation is the principle cause of the ion-beam implantation biological effects, and revealed the complex molecular networks required to adapt to ion-beam implantation stress in plants, including enhanced transposition of transposable elements, promoted ABA biosynthesis and changes in chromatin modification. Our data will extend the current understanding of the molecular mechanisms and gene regulation of stimulation effects. Further research on the candidates reported in this study should provide new insights into the molecular mechanisms of biological effects induced by ion-beam implantation. PMID:22843621
[Quenched fluorescein: a reference dye for instrument response function of TCSPC].
Pan, Hai-feng; Ding, Jing-xin; Liang, Rong-rong; Tao, Zhan-dong; Liu, Meng-wei; Zhang, San-jun; Xu, Jian-hua
2014-08-01
Measuring the instrument response function (IRF) and fitting by reconvolution algorithms are routines to improve time resolution in fluorescence lifetime measurements. Iodide ions were successfully used to quench the fluorescence of fluorescein in this study. By systematically adding saturated NaI water solution in basic fluorescein solution, the lifetimes of fluorescein were reduced from 4 ns to 24 ps. The quenched lifetime of fluorescein obtained from the analysis of Time-Correlated Single Photon Counting (TCSPC) measurement agrees well with that from femtosecond frequency up-conversion measurement. In time resolved excitation spectra measurements, the IRF should be measured at various detection wavelengths providing scattring materials are used. This study could not only reduce the complexity of IRF measurement, but also avoid the existing color effect in system. This study should have wide applications in time resolved fluorescence spectroscopy and fluorescence lifetime imaging.
Cochlear implants and ex vivo BDNF gene therapy protect spiral ganglion neurons.
Rejali, Darius; Lee, Valerie A; Abrashkin, Karen A; Humayun, Nousheen; Swiderski, Donald L; Raphael, Yehoash
2007-06-01
Spiral ganglion neurons often degenerate in the deaf ear, compromising the function of cochlear implants. Cochlear implant function can be improved by good preservation of the spiral ganglion neurons, which are the target of electrical stimulation by the implant. Brain derived neurotrophic factor (BDNF) has previously been shown to enhance spiral ganglion survival in experimentally deafened ears. Providing enhanced levels of BDNF in human ears may be accomplished by one of several different methods. The goal of these experiments was to test a modified design of the cochlear implant electrode that includes a coating of fibroblast cells transduced by a viral vector with a BDNF gene insert. To accomplish this type of ex vivo gene transfer, we transduced guinea pig fibroblasts with an adenovirus with a BDNF gene cassette insert, and determined that these cells secreted BDNF. We then attached BDNF-secreting cells to the cochlear implant electrode via an agarose gel, and implanted the electrode in the scala tympani. We determined that the BDNF expressing electrodes were able to preserve significantly more spiral ganglion neurons in the basal turns of the cochlea after 48 days of implantation when compared to control electrodes. This protective effect decreased in the higher cochlear turns. The data demonstrate the feasibility of combining cochlear implant therapy with ex vivo gene transfer for enhancing spiral ganglion neuron survival.
NASA Astrophysics Data System (ADS)
Monsees, Thomas
2016-08-01
With regard to biocompatibility, the cardinal requirement for dental implants and other medical devices that are in long-term contact with tissue is that the material does not cause any adverse effect to the patient. To warrant stability and function of the implant, proper osseointegration is a further prerequisite. Cells interact with the implant surface as the interface between bulk material and biological tissue. Whereas structuring, deposition of a thin film or other modifications of the surface are crucial parameters in determining favorable adhesion of cells, corrosion of metal surfaces and release of ions can affect cell viability. Both parameters are usually tested using in vitro cytotoxicity and adhesion assays with bone or fibroblasts cells. For bioactive surface modifications, further tests should be considered for biocompatibility evaluation. Depending on the type of modification, this may include analysis of specific cell functions or the determination of antimicrobial activities. The latter is of special importance as bacteria and yeast present in the oral cavity can be introduced during the implantation process and this may lead to chronic infections and implant failure. An antimicrobial coating of the implant is a way to avoid that. This review describes the essential biocompatibility assays for evaluation of new implant materials required by ISO 10993 and also gives an overview on recent test methods for specific coatings of dental implants.
Wireless Power Transfer Strategies for Implantable Bioelectronics.
Agarwal, Kush; Jegadeesan, Rangarajan; Guo, Yong-Xin; Thakor, Nitish V
2017-01-01
Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.
Schoonbeek, Rosanne C; Takebayashi, Satoshi; Aoki, Chikashi; Shimaoka, Toru; Harris, Matthew A; Fu, Gregory L; Kim, Timothy S; Dori, Yoav; McGarvey, Jeremy; Litt, Harold; Bouma, Wobbe; Zsido, Gerald; Glatz, Andrew C; Rome, Jonathan J; Gorman, Robert C; Gorman, Joseph H; Gillespie, Matthew J
2016-10-01
Pulmonary insufficiency is the nexus of late morbidity and mortality after transannular patch repair of tetralogy of Fallot. This study aimed to establish the feasibility of implantation of the novel Medtronic Harmony transcatheter pulmonary valve (hTPV) and to assess its effect on pulmonary insufficiency and ventricular function in an ovine model of chronic postoperative pulmonary insufficiency. Thirteen sheep underwent baseline cardiac magnetic resonance imaging, surgical pulmonary valvectomy, and transannular patch repair. One month after transannular patch repair, the hTPV was implanted, followed by serial magnetic resonance imaging and computed tomography imaging at 1, 5, and 8 month(s). hTPV implantation was successful in 11 animals (85%). There were 2 procedural deaths related to ventricular fibrillation. Seven animals survived the entire follow-up protocol, 5 with functioning hTPV devices. Two animals had occlusion of hTPV with aneurysm of main pulmonary artery. A strong decline in pulmonary regurgitant fraction was observed after hTPV implantation (40.5% versus 8.3%; P=0.011). Right ventricular end diastolic volume increased by 49.4% after transannular patch repair (62.3-93.1 mL/m 2 ; P=0.028) but was reversed to baseline values after hTPV implantation (to 65.1 mL/m 2 at 8 months, P=0.045). Both right ventricular ejection fraction and left ventricular ejection fraction were preserved after hTPV implantation. hTPV implantation is feasible, significantly reduces pulmonary regurgitant fraction, facilitates right ventricular volume improvements, and preserves biventricular function in an ovine model of chronic pulmonary insufficiency. This percutaneous strategy could potentially offer an alternative for standard surgical pulmonary valve replacement in dilated right ventricular outflow tracts, permitting lower risk, nonsurgical pulmonary valve replacement in previously prohibitive anatomies. © 2016 American Heart Association, Inc.
Energy Savings Lifetimes and Persistence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffman, Ian M.; Schiller, Steven R.; Todd, Annika
2016-02-01
This technical brief explains the concepts of energy savings lifetimes and savings persistence and discusses how program administrators use these factors to calculate savings for efficiency measures, programs and portfolios. Savings lifetime is the length of time that one or more energy efficiency measures or activities save energy, and savings persistence is the change in savings throughout the functional life of a given efficiency measure or activity. Savings lifetimes are essential for assessing the lifecycle benefits and cost effectiveness of efficiency activities and for forecasting loads in resource planning. The brief also provides estimates of savings lifetimes derived from amore » national collection of costs and savings for electric efficiency programs and portfolios.« less
Salgado, Dawn M; Quinlan, Kristen J; Zlotnick, Caron
2007-01-01
There is a dearth of literature examining the relationship between trauma-related experiences, PTSD, and lifetime polysubstance dependence among incarcerated women. A sample of 69 treatment-seeking incarcerated women with current PTSD and comorbid substance use disorder (PTSD-SUD) were recruited from a northeastern state medium-security prison. Women with lifetime polysubstance dependence (PTSD-SUD/LPD; n = 33) were compared to women with no lifetime polysubstance dependence (PTSD-SUD only; n = 36) across a range of features; trauma characteristics (e.g., number of traumas, type of trauma), associated symptoms (e.g., dissociation, anxiety), severity of substance use and psychosocial functioning. Women with PTSD and lifetime polysubstance dependence reported greater severity of drug and alcohol use, increased exposure to traumatic events (i.e., general disasters, crime-related events), and increased prevalence of PTSDrelated symptoms (i.e., derealization, survivor guilt). Trends also suggest that PTSD-SUD/LPD women are more likely to experience dissociation, anxiety, and sexual problems than PTSD-SUD respondents. Treatment-related implications are discussed.
Sreeram, Roopa Rani S; Prasad, L Krishna; Chakravarthi, P Srinivas; Devi, Naga Neelima; Kattimani, Vivekanand S; Sreeram, Sanjay Krishna
2015-08-01
Missing teeth lead to loss of structural balance, inefficient function, poor aesthetics and psychological effects on human beings, which needs restoration for normal contour, function and aesthetics. Several natural or synthetic substitutes are being used for replacement of missing tooth since centuries. Implants are the latest modality of replacement. So, the study was aimed to assess clinical success rate of Hi-Tec implant; which is economical and new in market. Results of the study will help clinician for appropriate implant selection. The study included 10 patients from 19 to 31 years and needed restoration of missing mandibular first molar. Restoration had done using Hi Tec Single-tooth implants with metal-ceramic single crown prosthesis after three months of osseointegration. The implants were evaluated clinically (bleeding on probing, probing depth, implant mobility- periotest) and radiographically (marginal bone loss and peri-implant radiolucency) for six years. The observers were blinded for the duration of the study to prevent bias. All the patients had uneventful post-surgical healing. No bleeding on probing, Implant mobility, peri-implant radiolucency with minimal marginal bone loss and constant probing depths were observed well within the normal range during follow-up periods. Two stage single-tooth Hi Tec implant restoration can be used as a successful treatment modality for replacing mandibular first molar in an economic way. However, these results were obtained after 6 years of follow up with a smaller sample size, so long term multi center studies with a larger sample size is recommended for the predictability of success rate conclusively.
Wei, Niu; Bin, Shi; Jing, Zhou; Wei, Sun; Yingqiong, Zhao
2014-06-01
To evaluate the short- and mid-term effects of commercial pure (cp) titanium implant surface topography on osseointegration, bone-regenerative potential and mechanical retention in the human maxilla and mandible. 32 micro-implants with the same geometry but with four different surface treatments were implanted in the maxilla and mandible of eight patients. Each patient received four micro-implants, one of each type. Percentage of bone-to-implant contact analysis and histological evaluation was carried 3, 6 and 12 weeks after implantation. Furthermore, reverse removal torque tests were conducted 3 and 6 weeks after implantation to analyze functional bone attachment. Implant surfaces tested were: machined, grit-blasted, acid-etched, and grit-blasted with acid-etch. One-way ANOVA was performed using the multiple comparison Fisher's test to determine significance of observed differences among test groups. The level of significance was established at 5% (P < 0.05). Mean and standard deviations of the test groups were calculated. Surface roughness had a significant correlation with the evolution of bone regeneration. The surfaces with roughness Ra approximately 4 microim (grit-blasted and grit-blasted with acid-etch), showed rapid tissue colonization compared to machine and acid-etched surfaces. The results of reverse removal torque tests confirmed a significant correlation between surface roughness and functional bone attachment. Grit-blasted and grit-blasted with acid etched surfaces showed higher retention values compared to machine and acid-etched implants. This finding was supported by higher bone-to-implant contact observed for rougher surfaces (grit-blasted and grit-blasted with acid etching).
De Faveri, Sara; Maggiolini, Emma; Miele, Ermanno; De Angelis, Francesco; Cesca, Fabrizia; Benfenati, Fabio; Fadiga, Luciano
2014-01-01
The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes - over time - compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses.
NASA Astrophysics Data System (ADS)
Richter, Asta; Anwand, Wolfgang; Chen, Chun-Liang; Böttger, Roman
2017-10-01
Helium implanted tungsten-titanium ODS alloys are investigated using positron annihilation spectroscopy and nanoindentation. Titanium reduces the brittleness of the tungsten alloy, which is manufactured by mechanical alloying. The addition of Y2O3 nanoparticles increases the mechanical properties at elevated temperature and enhances irradiation resistance. Helium ion implantation was applied to simulate irradiation effects on these materials. The irradiation was performed using a 500 kV He ion implanter at fluences around 5 × 1015 cm-2 for a series of samples both at room temperature and at 600 °C. The microstructure and mechanical properties of the pristine and irradiated W-Ti-ODS alloy are compared with respect to the titanium and Y2O3 content. Radiation damage is studied by positron annihilation spectroscopy analyzing the lifetime and the Doppler broadening. Three types of helium-vacancy defects were detected after helium irradiation in the W-Ti-ODS alloy: small defects with high helium-to-vacancy ratio (low S parameter) for room temperature irradiation, larger open volume defects with low helium-to-vacancy ratio (high S parameter) at the surface and He-vacancy complexes pinned at nanoparticles deeper in the material for implantation at 600 °C. Defect induced hardness was studied by nanoindentation. A drastic hardness increase is observed after He ion irradiation both for room temperature and elevated irradiation temperature of 600 °C. The Ti alloyed tungsten-ODS is more affected by the hardness increase after irradiation compared to the pure W-ODS alloy.
Enhanced Magnetization of Cobalt Defect Clusters Embedded in TiO 2-δ Films
Cortie, David L.; Khaydukov, Yury; Keller, Thomas; ...
2017-02-23
High magnetizations are desirable for spintronic devices that operate by manipulating electronic states using built-in magnetic fields. However, the magnetic moment in promising dilute magnetic oxide nanocomposites is very low, typically corresponding to only fractions of a Bohr magneton for each dopant atom. In this study, we report a large magnetization formed by ion implantation of Co into amorphous TiO 2-δ films, producing an inhomogeneous magnetic moment, with certain regions producing over 2.5 μ B per Co, depending on the local dopant concentration. Polarized neutron reflectometry was used to depth-profile the magnetization in the Co:TiO 2-δ nanocomposites, thus confirming themore » pivotal role of the cobalt dopant profile inside the titania layer. X-ray photoemission spectra demonstrate the dominant electronic state of the implanted species is Co 0, with a minor fraction of Co 2+. The detected magnetizations have seldom been reported before and lie near the upper limit set by Hund’s rules for Co 0, which is unusual because the transition metal’s magnetic moment is usually reduced in a symmetric 3D crystal-field environment. Low-energy positron annihilation lifetime spectroscopy indicates that defect structures within the titania layer are strongly modified by the implanted Co. We propose that a clustering motif is promoted by the affinity of the positively charged implanted species to occupy microvoids native to the amorphous host. This provides a seed for subsequent doping and nucleation of nanoclusters within an unusual local environment.« less
Functional outcome of vocal fold medialization thyroplasty with a hydroxyapatite implant.
Storck, Claudio; Brockmann, Meike; Schnellmann, Elvira; Stoeckli, Sandro J; Schmid, Stephan
2007-06-01
Unilateral vocal fold paralysis can cause a persistent incomplete glottal closure during phonation, resulting in impaired voice function. The aim of this study was to evaluate functional results of medialization thyroplasty using a hydroxyapatite implant (VoCoM). Prospective observational cohort study. Between 1999 and 2003, a total of 26 patients (19 men, 7 women) undergoing medialization thyroplasty using a hydroxyapatite implant because of unilateral vocal fold paralysis were enrolled in the study. To evaluate voice function, the following parameters were measured preoperatively and postoperatively: mean fundamental frequency, mean sound pressure level, frequency and amplitude range (voice range profile), and maximum phonation time. A perceptual assessment of hoarseness was conducted using the Roughness, Breathiness, Hoarseness scale. Furthermore, the magnitude of voice related impairment of the patient's communication skills was rated on a 7-point scale. A combined parameter called the Voice Dysfunction Index (VDI) was used to rate vocal performance. All patients showed a statistically significant improvement in the VDI, in perceptual voice analysis, in maximum phonation time, and in the dynamic range of voice. One patient experienced a postoperative wound hemorrhage as a minor complication. No further complications or implant extrusions were observed. Medialization thyroplasty using a hydroxyapatite implant is a secure and efficient phonosurgical procedure. Voice quality and patient satisfaction improve significantly after treatment.
2016-10-01
platysma muscle (top red) and trapezius muscle (bottom blue). Bottom Clamshell Side View Cooled water flows through tubing Rubber Tubing Plastic...Enclosure Top View Top Clamshell Top View Side View Top View Cooled water flows through tubing Rubber Tubing Plastic Enclosure Figure 3. Descriptive...typical of the uptake of implanted neuromodulation devices [e.g. cochlear implants, bladder implants, hand neuroprosthesis]. This approach maximizes
Investigation of hydrogen interaction with defects in zirconia
NASA Astrophysics Data System (ADS)
Melikhova, O.; Kuriplach, J.; Čížek, J.; Procházka, I.; Brauer, G.; Anwand, W.
2010-04-01
Defect studies of a ZrO2 + 9 mol. % Y2O3 single crystal were performed in this work using a high resolution positron lifetime spectroscopy combined with slow positron implantation spectroscopy. In order to elucidate the nature of positron trapping sites observed experimentally, the structural relaxations of several types of vacancy-like defects in zirconia were performed and positron characteristics for them were calculated. Relaxed atomic configurations of studied defects were obtained by means of ab initio pseudopotential method within the supercell approach. Theoretical calculations indicated that neither oxygen vacancies nor their neutral complexes with substitute yttrium atoms are capable of positron trapping. On the other hand, zirconium vacancies are deep positron traps and are most probably responsible for the saturated positron trapping observed in yttria stabilized zirconia single crystals. However, the calculated positron lifetime for zirconium vacancy is apparently longer than the experimental value corresponding to a single-component spectrum measured for the cubic ZrO2 + 9 mol. % Y2O3 single crystal. It was demonstrated that this effect can be explained by hydrogen trapped in zirconium vacancies. On the basis of structure relaxations, we found that zirconium vacancy - hydrogen complexes represent deep positron traps with the calculated lifetime close to the experimental one. In zirconium vacancy - hydrogen complexes the hydrogen atom forms an O-H bond with one of the nearest neighbour oxygen atoms. The calculated bond length is close to 1 Å.
Positron annihilation in SiO 2-Si studied by a pulsed slow positron beam
NASA Astrophysics Data System (ADS)
Suzuki, R.; Ohdaira, T.; Uedono, A.; Kobayashi, Y.
2002-06-01
Positron and positronium (Ps) behavior in SiO 2-Si have been studied by means of positron annihilation lifetime spectroscopy (PALS) and age-momentum correlation (AMOC) spectroscopy with a pulsed slow positron beam. The PALS study of SiO 2-Si samples, which were prepared by a dry-oxygen thermal process, revealed that the positrons implanted in the Si substrate and diffused back to the interface do not contribute to the ortho-Ps long-lived component, and the lifetime spectrum of the interface has at least two components. From the AMOC study, the momentum distribution of the ortho-Ps pick-off annihilation in SiO 2, which shows broader momentum distribution than that of crystalline Si, was found to be almost the same as that of free positron annihilation in SiO 2. A varied interface model was proposed to interpret the results of the metal-oxide-semiconductor (MOS) experiments. The narrow momentum distribution found in the n-type MOS with a negative gate bias voltage could be attributed to Ps formation and rapid spin exchange in the SiO 2-Si interface. We have developed a two-dimensional positron lifetime technique, which measures annihilation time and pulse height of the scintillation gamma-ray detector for each event. Using this technique, the positronium behavior in a porous SiO 2 film, grown by a sputtering method, has been studied.
The fate of paternal mitochondria in marmoset pre-implantation embryos.
Luetjens, C M; Wesselmann, R
2008-06-01
Sperm-derived mitochondria are integrated into the oocyte at fertilization but seem to vanish during the early cleavage phase. The developmental potential of pre-implantation embryos seems to be closely related to their ability to induce degeneration of these mitochondria, but the mechanisms underlying their loss of function are not yet understood. This study focuses on the fate of paternal mitochondria in pre-implantation embryos. Stimulation, collection and in vitro culture of oocytes from Callithrix jacchus, allows the study of the destiny of paternal mitochondria by utilizing immunostaining of pre-implantation embryos, fluorescence and laserscanning microscopy. Live pre-implantation embryos were stained with a fluorescence indicator reflecting mitochondrial membrane potential. Evidence indicating the loss of mitochondrial function was not found nor that apoptosis pathways were involved in the disappearance of paternally derived mitochondria. These findings may have implications for mitochondrially inherited diseases and could lead to new strategies for improving assisted reproduction.
Neuroprotective effect of subretinal implants in the RCS rat.
Pardue, Machelle T; Phillips, Michael J; Yin, Hang; Sippy, Brian D; Webb-Wood, Sarah; Chow, Alan Y; Ball, Sherry L
2005-02-01
Retinal prosthetics have been designed to interface with the neural retina by electrically stimulating the remaining retinal circuits after photoreceptor degeneration. However, the electrical stimulation provided by the subretinal implant may also stimulate neurotrophic factors that provide neuroprotection to the retina. This study was undertaken to determine whether electrical stimulation from a subretinal photodiode-based implant has a neuroprotective effect on photoreceptors in the RCS rat, a model of photoreceptor degeneration. Eyes of RCS rats were implanted with an active or inactive device or underwent sham surgery before photoreceptor degeneration. Outer retinal function was assessed with electroretinogram (ERG) recordings weekly until 8 weeks after surgery, at which time retinal tissue was collected and processed for morphologic assessment, including photoreceptor cell counts and retinal layer thickness. At 4 to 6 weeks after surgery, the ERG responses in the active-implant eyes were 30% to 70% greater in b-wave amplitude than the responses from eyes implanted with inactive devices, those undergoing sham surgery, or the nonsurgical control eyes. At 8 weeks after surgery the ERG responses from active-implant eyes were not significantly different from the control groups. However, the number of photoreceptors in eyes implanted with the active or inactive device was significantly greater in the regions over and around the implant versus sham-surgical and nonsurgical control eyes. These results suggest that subretinal electrical stimulation provides temporary preservation of retinal function in the RCS rat. In addition, implantation of an active or inactive device into the subretinal space causes morphologic preservation of photoreceptors in the RCS rat until 8 weeks after surgery. Further studies are needed to determine whether the correlation of neuropreservation with subretinal implantation is due to electrical stimulation and/or a mechanical presence of the implant in the subretinal space.
NASA Astrophysics Data System (ADS)
Mihailescu, Ion N.; Ristoscu, Carmen; Bigi, Adriana; Mayer, Isaac
Calcium phosphates (CaPs) are alternative substitutes for human bones and so primary candidates for the manufacture of medical implants. Unfortunately, they do not withstand stress in bulk. To overcome this obstacle, a solution was developed to cover metallic implants with functional biomimetic layers.
21 CFR 874.3695 - Mandibular implant facial prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mandibular implant facial prosthesis. 874.3695 Section 874.3695 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... intended to be implanted for use in the functional reconstruction of mandibular deficits. The device is...
21 CFR 874.3695 - Mandibular implant facial prosthesis.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Mandibular implant facial prosthesis. 874.3695 Section 874.3695 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... intended to be implanted for use in the functional reconstruction of mandibular deficits. The device is...
Immediate loading of titanium hexed screw-type implants in the edentulous patient: case report.
Calvo, M P; Muller, E; Garg, A K
2000-01-01
Histologic and histomorphometric studies in both animals and humans have shown that more rapid and greater bone-to-implant contact can be achieved with implants that incorporate certain surface characteristics compared with the original machined-surface implants. Such findings are significant because various implant designs may allow the fixtures to sufficiently resist functional loading sooner than originally thought. The case report presented here indicates that immediate loading of hexed titanium screw-type implants in the anterior mandible can lead to successful osseointegration and clinical outcome. The number of implants placed, their distribution, and the type of rigid connection are critical considerations for immediate loading. A bone height that can accommodate dental implants > or = 10 mm long is recommended. Biomechanically, the implants to be immediately loaded must be stable and resistant to macromovement to ensure good osseointegration.
Modelling lifetime cost consequences of ReSTOR® in cataract surgery in four European countries
Lafuma, Antoine; Berdeaux, Gilles
2008-01-01
Background To compare the lifetime costs of liberating patients from spectacles after cataract surgery by implanting the multifocal intraocular lens (IOL) 'ReSTOR®' versus monofocal IOLs in France, Italy, Germany and Spain. Methods A Markov model was created to follow patient cohorts from cataract surgery until death. Prevalence rates of patients not needing spectacles after cataract surgery were obtained from clinical trials. Resource utilisation included implant surgery, IOLs, spectacles, visits to ophthalmologists and eye centres, transport, and time lost by patients. Economic perspectives were those of Society and Sickness Funds (SFs). Results The mean number of spectacles purchased after ReSTOR® was 1.34–1.61 and after monofocal IOLs 6.05–7.27. From the societal perspective, total cost estimates discounted by 3% were between €3,551 and €4,052 with ReSTOR® compared to €3,989 and €5,548 with monofocal IOLs. Undiscounted savings related to ReSTOR® ranged from €815 to €2,164. From the SFs' perspective total cost estimates discounted by 3% were between €2,150 and €2,524 with ReSTOR® compared to €2,324 and €2,610 with monofocal IOLs. Savings related to ReSTOR®, once costs discounted, ranged from €61 to €219. Discount and spectacle freedom prevalence rates were the most sensitive parameters. Conclusion The bulk of the savings related to ReSTOR® were realized outside the SF. From both a societal and SF perspective, savings, after a 3% discounting, achieved by liberating patients from spectacles counterbalanced the initially higher cost of ReSTOR®. ReSTOR® is a cost saving alternative to spectacles for patients requiring cataract surgery. PMID:18627594
Philibert, Robert A; Beach, Steven R H; Gunter, Tracy D; Todorov, Alexandre A; Brody, Gene H; Vijayendran, Meeshanthini; Elliott, Lilly; Hollenbeck, Nancy; Russell, Daniel; Cutrona, Carolyn
2011-07-01
Major depression (MD) is often associated with disturbances of the hypothalamic/pituitary/thyroid (HPT) axis. Unfortunately, whether this association is secondary to common underlying genetic variation or whether the MD-associated disturbances in HPT function are chronic or state-dependent is unknown. To examine these questions, we genotyped 12 single nucleotide polymorphisms identified in previous genome wide association analyses of thyroid function in DNA contributed by 1,555 subjects from three longitudinal ethnically diverse studies that are well-characterized for lifetime MD and thyroid function. We then examined associations between genetic variants and key outcomes of thyroid stimulating hormone, free thyroxine (FT4) and depression. We confirmed prior findings that two variants in deiodinase 1 (DIO1), including a variant in the 3'UTR of DIO1 (rs11206244), were associated with altered FT4 levels in both White and African American subjects. We also found that rs11206244 genotype was associated with lifetime MD in White female subjects, in particular those from high-risk cohorts. However, we found no association of current FT4 levels with lifetime MD in either ethnic group. We conclude that genetic variation influencing thyroid function is a risk factor for MD. Given the evidence from prior studies, further investigations of role of HPT variation in etiology and treatment of MD are indicated. Copyright © 2011 Wiley-Liss, Inc.
Philibert, Robert A.; Beach, Steven R. H.; Gunter, Tracy D.; Todorov, Alexandre A.; Brody, Gene H.; Vijayendran, Meeshanthini; Elliott, Lilly; Hollenbeck, Nancy; Russell, Daniel; Cutrona, Carolyn
2011-01-01
Major depression (MD) is often associated with disturbances of the hypothalamic/pituitary/thyroid (HPT) axis. Unfortunately, whether this association is secondary to common underlying genetic variation or whether the MD-associated disturbances in HPT function are chronic or state-dependent is unknown. To examine these questions, we genotyped 12 single nucleotide polymorphisms identified in previous genome wide association analyses of thyroid function in DNA contributed by 1555 subjects from three longitudinal ethnically diverse studies that are well-characterized for lifetime major depression and thyroid function. We then examined associations between genetic variants and key outcomes of thyroid stimulating hormone (TSH), free thyroxine (FT4) and depression. We confirmed prior findings that two variants in deiodinase 1 (DIO1), including a variant in the 3’ UTR of DIO1 (rs11206244), were associated with altered free thyroxine (FT4) levels in both White and African American subjects. We also found that rs11206244 genotype was associated with lifetime MD in White female subjects, in particular those from high-risk cohorts. However, we found no association of current FT4 levels with lifetime MD in either ethnic group. We conclude that genetic variation influencing thyroid function is a risk factor for MD. Given the evidence from prior studies, further investigations of role of HPT variation in etiology and treatment of MD are indicated. PMID:21563302
Engen, Steinar; Saether, Bernt-Erik
2017-01-01
In a stable environment, evolution maximizes growth rates in populations that are not density regulated and the carrying capacity in the case of density regulation. In a fluctuating environment, evolution maximizes a function of growth rate, carrying capacity and environmental variance, tending to r-selection and K-selection under large and small environmental noise, respectively. Here we analyze a model in which birth and death rates depend on density through the same function but with independent strength of density dependence. As a special case, both functions may be linear, corresponding to logistic dynamics. It is shown that evolution maximizes a function of the deterministic growth rate r 0 and the lifetime reproductive success (LRS) R 0 , both defined at small densities, as well as the environmental variance. Under large noise this function is dominated by r 0 and average lifetimes are small, whereas R 0 dominates and lifetimes are larger under small noise. Thus, K-selection is closely linked to selection for large R 0 so that evolution tends to maximize LRS in a stable environment. Consequently, different quantities (r 0 and R 0 ) tend to be maximized at low and high densities, respectively, favoring density-dependent changes in the optimal life history. © 2016 The Author(s). Evolution © 2016 The Society for the Study of Evolution.
Ring, Andrej; Langer, Stefan; Tilkorn, Daniel; Goertz, Ole; Henrich, Lena; Stricker, Ingo; Steinau, Hans-Ulrich; Steinstraesser, Lars; Hauser, Joerg
2010-09-28
Formation of encapsulating, avascular fibrous tissue is deemed to decrease implant's biocompatibility and versatility. We investigated whether plasma-mediated collagen coating possesses the ability to enhance neovascularization in the vicinity of silicone implants. Plasma-treated collagen-I-coated silicone samples were placed into the dorsal skinfold chambers of female balb/c mice (n = 10). Conventional silicone served as control (n = 10). Intravital microscopy was performed within implant's surrounding tissue on days 1, 5, and 10. Functional vessel density, intervascular distance, vessel diameter, microvascular permeability, red blood cell velocity, and leukocyte-endothelium interaction were determined. Enhanced angiogenesis in the tissue surrounding plasma-pretreated collagen-coated implants was noted. Significant increase of functional vessel density due to vascular new development was observed (t test, P < .05). Analyses of microvascular permeability and red blood cell velocity displayed stable perfusion of the vascular network neighboring the surface-modified implants. Intensified vascularity due to induced angiogenesis and neovascularization in the tissue surrounding plasma-collagen-coated samples were observed. These results indicate that plasma-mediated collagen coating might be a promising technology in order to improve the biocompatibility and versatility of silicone implants.
Ring, Andrej; Langer, Stefan; Tilkorn, Daniel; Goertz, Ole; Henrich, Lena; Stricker, Ingo; Steinau, Hans-Ulrich; Steinstraesser, Lars; Hauser, Joerg
2010-01-01
Objective: Formation of encapsulating, avascular fibrous tissue is deemed to decrease implant's biocompatibility and versatility. We investigated whether plasma-mediated collagen coating possesses the ability to enhance neovascularization in the vicinity of silicone implants. Methods: Plasma-treated collagen-I–coated silicone samples were placed into the dorsal skinfold chambers of female balb/c mice (n = 10). Conventional silicone served as control (n = 10). Intravital microscopy was performed within implant's surrounding tissue on days 1, 5, and 10. Functional vessel density, intervascular distance, vessel diameter, microvascular permeability, red blood cell velocity, and leukocyte-endothelium interaction were determined. Results: Enhanced angiogenesis in the tissue surrounding plasma-pretreated collagen-coated implants was noted. Significant increase of functional vessel density due to vascular new development was observed (t test, P < .05). Analyses of microvascular permeability and red blood cell velocity displayed stable perfusion of the vascular network neighboring the surface-modified implants. Conclusion: Intensified vascularity due to induced angiogenesis and neovascularization in the tissue surrounding plasma-collagen–coated samples were observed. These results indicate that plasma-mediated collagen coating might be a promising technology in order to improve the biocompatibility and versatility of silicone implants. PMID:20936137
Durability of implanted electrodes and leads in an upper-limb neuroprosthesis.
Kilgore, Kevin L; Peckham, P Hunter; Keith, Michael W; Montague, Fred W; Hart, Ronald L; Gazdik, Martha M; Bryden, Anne M; Snyder, Scott A; Stage, Thomas G
2003-01-01
Implanted neuroprosthetic systems have been successfully used to provide upper-limb function for over 16 years. A critical aspect of these implanted systems is the safety, stability, and-reliability of the stimulating electrodes and leads. These components are (1) the stimulating electrode itself, (2) the electrode lead, and (3) the lead-to-device connector. A failure in any of these components causes the direct loss of the capability to activate a muscle consistently, usually resulting in a decrement in the function provided by the neuroprosthesis. Our results indicate that the electrode, lead, and connector system are extremely durable. We analyzed 238 electrodes that have been implanted as part of an upper-limb neuroprosthesis. Each electrode had been implanted at least 3 years, with a maximum implantation time of over 16 years. Only three electrode-lead failures and one electrode infection occurred, for a survival rate of almost 99 percent. Electrode threshold measurements indicate that the electrode response is stable over time, with no evidence of electrode migration or continual encapsulation in any of the electrodes studied. These results have an impact on the design of implantable neuroprosthetic systems. The electrode-lead component of these systems should no longer be considered a weak technological link.
NASA Astrophysics Data System (ADS)
Suzuki, Kunihiro
2009-04-01
Ion implantation profiles are expressed by the Pearson function with first, second, third, and fourth moment parameters of Rp, ΔRp, γ, and β. We derived an analytical model for these profile moments by solving a Lindhard-Scharf-Schiott (LSS) integration equation using perturbation approximation. This analytical model reproduces Monte Carlo data that were well calibrated to reproduce a vast experimental database. The extended LSS theory is vital for instantaneously predicting ion implantation profiles with any combination of incident ions and substrate atoms including their energy dependence.
Šćepanović, Miodrag; Todorović, Aleksandar; Marković, Aleksa; Patrnogić, Vesna; Miličić, Biljana; Moufti, Adel M; Mišić, Tijana
2015-05-01
This 1-year cohort study investigated stability and peri-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures. Each of 30 edentulous patients received 4 mini dental implants (1.8 mm × 13 mm) in the interforaminal mandibular region. The implants were immediately loaded with pre-made overdentures. Outcome measures included implant stability and bone resorption. Implant stability was measured using the Periotest Classic(®) device immediately after placement and on the 3rd and 6th weeks and the 4th, 6th and 12th months postoperatively. The peri-implant marginal bone level (PIBL) was evaluated at the implant's mesial and distal sides from the polished platform to the marginal crest. Radiographs were taken using a tailored film holder to reproducibly position the X-ray tube at the 6th week, 4th and 12th months postoperatively. The primary stability (Periotest value, PTV) measured -0.27 ± 3.41 on a scale of -8 to + 50 (lower PTV reflects higher stability). The secondary stability decreased significantly until week 6 (mean PTV = 7.61 ± 7.05) then increased significantly reaching (PTV = 6.17 ± 6.15) at 12 months. The mean PIBL measured -0.40 mm after 1 year of functional loading, with no statistically significant differences at the various follow-ups (p = 0.218). Mini dental implants placed into the interforaminal region could achieve a favorable primary stability for immediate loading. The follow-up Periotest values fluctuated, apparently reflecting the dynamics of bone remodeling, with the implants remaining clinically stable (98.3%) after 1 year of function. The 1-year bone resorption around immediately loaded MDIs is within the clinically acceptable range for standard implants. Copyright © 2014 Elsevier GmbH. All rights reserved.
Wearable Wireless Telemetry System for Implantable Bio-MEMS Sensors
NASA Technical Reports Server (NTRS)
Simons, Rainee N.; Miranda, Felix A.; Wilson, Jeffrey D.; Simons, Renita E.
2006-01-01
In this paper, a telemetry and contact-less powering system consisting of an implantable bio-MEMS sensor with a miniature printed square spiral chip antenna and an external wearable garment with printed loop antenna is investigated. The wearable garment pick-up antenna and the implantable chip antenna are in close proximity to each other and hence couple inductively through their near-fields and behave as the primary and the secondary circuits of a transformer, respectively. The numerical and experimental results are graphically presented, and include the design parameter values as a function of the geometry, the relative RF magnetic near-field intensity as a function of the distance and angle, and the current density on the strip conductors, for the implantable chip antenna.
Depth resolved investigations of boron implanted silicon
NASA Astrophysics Data System (ADS)
Sztucki, M.; Metzger, T. H.; Milita, S.; Berberich, F.; Schell, N.; Rouvière, J. L.; Patel, J.
2003-01-01
We have studied the depth distribution and structure of defects in boron implanted silicon (0 0 1). Silicon wafers were implanted with a boron dose of 6×10 15 ions/cm -2 at 32 keV and went through different annealing treatments. Using diffuse X-ray scattering at grazing incidence and exit angles we are able to distinguish between different kinds of defects (point defect clusters and extrinsic stacking faults on {1 1 1} planes) and to determine their depth distribution as a function of the thermal budget. Cross-section transmission electron microscopy was used to gain complementary information. In addition we have determined the strain distribution caused by the boron implantation as a function of depth from rocking curve measurements.
Soft Tissue Grafting Around Teeth and Implants.
Deeb, George R; Deeb, Janina Golob
2015-08-01
The presence of healthy attached tissue at the tooth and implant soft tissue interface correlates with long-term success and stability in function and esthetics. There are several soft tissue grafting procedures that increase the volume of keratinized tissue and provide coverage on both teeth and implants. Many of these techniques can be used in conjunction with implant placement, or after placement as a means of salvage. This article describes the techniques for augmentation of keratinized tissue as well as root and implant coverage. These tools should be in the armamentarium of oral and maxillofacial surgeons providing implant services. Copyright © 2015 Elsevier Inc. All rights reserved.
Hempel, John Martin
2015-12-01
The use of porous polyethylene in reconstructive surgery of the auricle is becoming increasingly accepted. This is a single-stage procedure providing pleasing cosmetic rehabilitation. Further advantages are the possibility of early implantation and the lack of complications caused by harvesting costal cartilage. Additional hearing restoration using middle ear implants allows functional rehabilitation at an early stage. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Use of Metallic Endosseous Implants as a Tooth Substitute
1975-11-25
is exposed in the oral cavity and placed in function with the opposing dentition. BACKGROUND An appraisal of published work in the field of dental ...implant reveals that the dental literature abounds with articles concerned with the use of implants. The reports are mainly of clinical procedures and...metallic blades driven into the bone to become an anchor for prosthetic appliances. A complete critical review of the literature on dental implants was
Executive Functioning and Speech-Language Skills Following Long-Term Use of Cochlear Implants
ERIC Educational Resources Information Center
Kronenberger, William G.; Colson, Bethany G.; Henning, Shirley C.; Pisoni, David B.
2014-01-01
Neurocognitive processes such as executive functioning (EF) may influence the development of speech-language skills in deaf children after cochlear implantation in ways that differ from normal-hearing, typically developing children. Conversely, spoken language abilities and experiences may also exert reciprocal effects on the development of EF.…
Todt, Ingo; Basta, Dietmar; Ernst, Arne
2008-01-01
To investigate the impact of different cochleostomy techniques on vestibular receptor integrity and vertigo after cochlear implantation. Retrospective cohort study. A total of 62 patients (17 to 84 years of age) underwent implantation via an anterior or round window insertion approach. Two groups of cochlear implant patients were compared with respect to their pre- and postoperative vestibular function and the occurrence of postoperative vertigo. The data were related to the different cochleostomy techniques. The patients were tested by a questionnaire (dizziness handicap inventory, DIH), caloric irrigation (vestibulo-ocular reflex, VOR) for the function of the lateral SCC and by vestibular evoked myogenic potential (VEMP) recordings for saccular function. Significant differences of postoperative VEMP responses (50% vs 13%) and electromystagmography (ENG) results (42.9% vs 9.4%) were found with respect to the 2 different insertion techniques. The number of patients with vertigo after the surgery as evidenced by DHI (23% vs 12.5%) was significantly different. The used round window approach for electrode insertion should be preferred to decrease the risk of loss of vestibular function and the occurrence of vertigo.
Xue, Ligang; Mikkelsen, Kristian Handberg
2013-03-01
The objective of this study was to assess the dose accuracy of NovoPen® 5 in delivering low, medium and high doses of insulin before and after simulated lifetime use. A secondary objective was to evaluate the durability of the pen and its memory function under various stress conditions designed to simulate conditions that may be encountered in everyday use of an insulin pen. All testing was conducted according to International Organization for Standardization guideline 11608-1, 2000 for pen injectors. Dose accuracy was measured for the delivery of 1 unit (U) (10 mg), 30 U (300 mg) and 60 U (600 mg) test medium in standard, cool and hot conditions and before and after simulated lifetime use. Dose accuracy was also tested after preconditioning in dry heat storage; cold storage; damp cyclical heat; shock, bump and vibration; free fall and after electrostatic charge and radiated field test. Memory function was tested under all temperature and physical conditions. NovoPen 5 maintained dosing accuracy and memory function at minimum, medium and maximum doses in standard, cool and hot conditions, stress tests and simulated lifetime use. The pens remained intact and retained dosing accuracy and a working memory function at all doses after exposure to variations in temperature and after physical challenge. NovoPen 5 was accurate at all doses tested and under various functionality tests. Its durable design ensured that the dose accuracy and memory function were retained under conditions of stress likely to be encountered in everyday use.
Berberi, Antoine N; Sabbagh, Joseph M; Aboushelib, Moustafa N; Noujeim, Ziad F; Salameh, Ziad A
2014-01-01
The aim of present investigation was to evaluate marginal bone level after 5-year follow-up of implants placed in healed ridges and fresh extraction sockets in maxilla with immediate loading protocol. Thirty-six patients in need of a single-tooth replacement in the anterior maxilla received 42 Astra Tech implants (Astra Tech Implant system™, Dentsply Implants, Mölndal, Sweden). Implants were placed either in healed ridges (group I) or immediately into fresh extraction sockets (group II). Implants were restored and placed into functional loading immediately by using a prefabricated abutment. Marginal bone level relative to the implant reference point was recorded at implant placement, crown cementation, 12, 36, and 60 months following loading using intra-oral radiographs. Measurements were made on the mesial and distal sides of each implant. Overall, two implants were lost from the group II, before final crown cementation: they were excluded from the study. The mean change in marginal bone loss (MBL) after implant placement was 0.26 ± 0.161 mm for 1 year, and 0.26 ± 0.171 mm for 3 years, and 0.21 ± 0.185 mm for 5 years in extraction sockets and was 0.26 ± 0.176 mm for 1 year and 0.21 ± 0.175 mm for 3 years, and 0.19 ± 0.172 mm for 5 years in healed ridges group. Significant reduction of marginal bone was more pronounced in implants inserted in healed ridges (P < 0.041) compared to fresh surgical extraction sockets (P < 0.540). Significant MBL was observed on the mesial side of the implant after cementation of the provisional (P < 0.007) and after 12 months (P < 0.034) compared to the distal side which remained stable for 3 and 5 years observation period. Within the limitations of this study, responses of local bone to immediately loaded implants placed either in extraction sockets or healed ridges were similar. Functional loading technique by using prefabricated abutment placed during the surgery time seems to maintain marginal bone around implant in both healed and fresh extraction sites.
Should children who use cochlear implants wear hearing aids in the opposite ear?
Ching, T Y; Psarros, C; Hill, M; Dillon, H; Incerti, P
2001-10-01
The aim of this study was to investigate 1) whether a hearing aid needs to be adjusted differently depending on whether a child wears a cochlear implant or another hearing aid in the contralateral ear; 2) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural interference; and 3) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural benefits in speech perception, localization, and communicative functioning in real life. Sixteen children participated in this study. All children used a Nucleus 22 or Nucleus 24 cochlear implant system programmed with the SPEAK strategy in one ear. The hearing aid amplification requirements in the nonimplanted ear of these children were determined using two procedures. A paired comparison technique was used to identify the frequency response that was best for speech intelligibility in quiet, and a loudness balancing technique was used to match the loudness of speech in the ear with a hearing aid to that with a cochlear implant. Eleven of the 16 children participated in the investigation of binaural effects. Performance in speech perception, localization, and communicative functioning was assessed under four aided conditions: cochlear implant with hearing aid as worn, cochlear implant alone, hearing aid alone, and cochlear implant with hearing aid adjusted according to individual requirements. Fifteen of the 16 children whose amplification requirements were determined preferred a hearing aid frequency response that was within +/-6 dB/octave of the NAL-RP prescription. On average, the children required 6 dB more gain than prescribed to balance the loudness of the implanted ear for a speech signal presented at 65 dB SPL. For all 11 children whose performance was evaluated for investigating binaural effects, there was no indication of significantly poorer performance under bilaterally aided conditions compared with unilaterally aided conditions. On average, there were significant benefits in speech perception, localization, and aural/oral function when the children used cochlear implants with adjusted hearing aids than when they used cochlear implants alone. All individuals showed benefits in at least one of the measures. Hearing aids for children who also use cochlear implants can be selected using the NAL-RP prescription. Adjustment of hearing aid gain to match loudness in the implanted ear can facilitate integration of signals from both ears, leading to better speech perception. Given that there are binaural advantages from using cochlear implants with hearing aids in opposite ears, clinicians should advise parents and other professionals about these potential advantages, and facilitate bilateral amplification by adjusting hearing aids after stable cochlear implant MAPs are established.
Wei, Fulan; Song, Tieli; Ding, Gang; Xu, Junji; Liu, Yi; Liu, Dayong; Fan, Zhipeng; Zhang, Chunmei
2013-01-01
Our previous proof-of-concept study showed the feasibility of regenerating the dental stem cell-based bioengineered tooth root (bio-root) structure in a large animal model. Here, we used allogeneic dental mesenchymal stem cells to regenerate bio-root, and then installed a crown on the bio-root to restore tooth function. A root shape hydroxyapatite tricalcium phosphate scaffold containing dental pulp stem cells was covered by a Vc-induced periodontal ligament stem cell sheet and implanted into a newly generated jaw bone implant socket. Six months after implantation, a prefabricated porcelain crown was cemented to the implant and subjected to tooth function. Clinical, radiological, histological, ultrastructural, systemic immunological evaluations and mechanical properties were analyzed for dynamic changes in the bio-root structure. The regenerated bio-root exhibited characteristics of a normal tooth after 6 months of use, including dentinal tubule-like and functional periodontal ligament-like structures. No immunological response to the bio-roots was observed. We developed a standard stem cell procedure for bio-root regeneration to restore adult tooth function. This study is the first to successfully regenerate a functional bio-root structure for artificial crown restoration by using allogeneic dental stem cells and Vc-induced cell sheet, and assess the recipient immune response in a preclinical model. PMID:23363023
Eap, Sandy; Bécavin, Thibault; Keller, Laetitia; Kökten, Tunay; Fioretti, Florence; Weickert, Jean-Luc; Deveaux, Etienne; Benkirane-Jessel, Nadia; Kuchler-Bopp, Sabine
2014-03-01
Current strategies for jaw reconstruction require multiple procedures, to repair the bone defect, to offer sufficient support, and to place the tooth implant. The entire procedure can be painful and time-consuming, and the desired functional repair can be achieved only when both steps are successful. The ability to engineer combined tooth and bone constructs, which would grow in a coordinated fashion with the surrounding tissues, could potentially improve the clinical outcomes and also reduce patient suffering. A unique nanofibrous and active implant for bone-tooth unit regeneration and also the innervation of this bioengineered tooth are demonstrated. A nanofibrous polycaprolactone membrane is functionalized with neural growth factor, along with dental germ, and tooth innervation follows. Such innervation allows complete functionality and tissue homeostasis of the tooth, such as dentinal sensitivity, odontoblast function, masticatory forces, and blood flow. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ERIC Educational Resources Information Center
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.; Lalonde, Kaylah
2012-01-01
Purpose: To evaluate the family environments of children with cochlear implants and to examine relationships between family environment and postimplant language development and executive function. Method: Forty-five families of children with cochlear implants completed a self-report family environment questionnaire (Family Environment Scale-Fourth…
Celik, Onder; Acet, Mustafa; Celik, Sudenaz; Sahin, Levent; Koc, Onder; Celik, Nilufer
2017-06-01
As with other organs endometrial functions are altered with the advancing age. Age related decrease in reproductive functions leads to decline in the number of oocytes retrieved and the synthesis of endometrial receptivity molecules. Despite the significant improvement in assisted reproductive technologies we do not have so many options to enhance endometrial receptivity. Due to lack of drugs having endometrium receptivity enhancement properties, oocyte donation seems to be the only solution for women with implantation failure. The euploid oocytes come from young and healthy donors may overcome age associated endometrial receptivity defect. Nevertheless, many reasons restrict us from using oocyte donation in women with implantation failure. We, therefore, hypothesized that by mimicking a young blastocyst's effect on endometrium, the transfer of genuine embryos and implantation-promoting compounds together might be the new treatment option for infertile women with recurrent implantation failure. Artificial beads, MI or GV oocytes, and empty zona can be used as a container for intrauterine replacement of implantation-promoting compounds. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pombo Castro, María; Luaces Rey, Ramón; Arenaz Búa, Jorge; Santana-Mora, Urbano; López-Cedrún Cembranos, José Luís
2013-10-01
Oral manifestations in ectodermal dysplasia include oligodontia, alveolar ridges hypoplasia, and others. Due to the special conditions in terms of unhealthy teeth and lack of bone, implant-supported rehabilitation seems to offer the most satisfactory outcome. A 27-year-old male diagnosed with ectodermal dysplasia was referred to our department for oral rehabilitation. Oral manifestations included oligodontia, maxillary and mandibular atrophy, mandibular alveolar ridge with knife-edge morphology, and conical teeth. Treatment planning consisted of a Le Fort I osteotomy with interpositional grafts, bilateral sinus lift, and placement of maxillary and mandibular inlay and onlay corticocancellous grafts, using autologous iliac crest bone. In the second surgery, all remaining teeth were removed and 11 endosteal implants were placed. Six months after implant placement, a bimaxillary fixed implant-supported prosthesis was delivered, maintaining a satisfactory esthetic and functional result after a 2-year follow-up. The use of combined preprosthetic techniques allows the placement of endosteal implants and a fixed implant-supported prosthesis in patients with oligodontia and ectodermal dysplasia, providing an esthetic and functional oral rehabilitation.
Deep brain stimulation with a pre-existing cochlear implant: Surgical technique and outcome.
Eddelman, Daniel; Wewel, Joshua; Wiet, R Mark; Metman, Leo V; Sani, Sepehr
2017-01-01
Patients with previously implanted cranial devices pose a special challenge in deep brain stimulation (DBS) surgery. We report the implantation of bilateral DBS leads in a patient with a cochlear implant. Technical nuances and long-term interdevice functionality are presented. A 70-year-old patient with advancing Parkinson's disease and a previously placed cochlear implant for sensorineural hearing loss was referred for placement of bilateral DBS in the subthalamic nucleus (STN). Prior to DBS, the patient underwent surgical removal of the subgaleal cochlear magnet, followed by stereotactic MRI, frame placement, stereotactic computed tomography (CT), and merging of imaging studies. This technique allowed for successful computational merging, MRI-guided targeting, and lead implantation with acceptable accuracy. Formal testing and programming of both the devices were successful without electrical interference. Successful DBS implantation with high resolution MRI-guided targeting is technically feasible in patients with previously implanted cochlear implants by following proper precautions.
Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser
2013-01-01
The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for vertical positioning between groups B and R. The P-value for rotational positioning between groups A and B and between groups A and R was <.001. No significant differences were found for rotational positioning between groups B and R. The results of the study confirmed that implant systems differ in precision of fit. Vertical precision between paired implant components is a function of joint type and the tightening force applied to the guide pin. The magnitude of vertical displacement with applied torque is greater for conical connections than for butt joint connections. The rotational freedom between paired components is unique to the implant system and is presumably related to the machining tolerances specified by the manufacturer. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Lindsay, Alistair C; Harron, Katie; Jabbour, Richard J; Kanyal, Ritesh; Snow, Thomas M; Sawhney, Paramvir; Alpendurada, Francisco; Roughton, Michael; Pennell, Dudley J; Duncan, Alison; Di Mario, Carlo; Davies, Simon W; Mohiaddin, Raad H; Moat, Neil E
2016-07-01
Cardiovascular magnetic resonance (CMR) can provide important structural information in patients undergoing transcatheter aortic valve implantation. Although CMR is considered the standard of reference for measuring ventricular volumes and mass, the relationship between CMR findings of right ventricular (RV) function and outcomes after transcatheter aortic valve implantation has not previously been reported. A total of 190 patients underwent 1.5 Tesla CMR before transcatheter aortic valve implantation. Steady-state free precession sequences were used for aortic valve planimetry and to assess ventricular volumes and mass. Semiautomated image analysis was performed by 2 specialist reviewers blinded to patient treatment. Patient follow-up was obtained from the Office of National Statistics mortality database. The median age was 81.0 (interquartile range, 74.9-85.5) years; 50.0% were women. Impaired RV function (RV ejection fraction ≤50%) was present in 45 (23.7%) patients. Patients with RV dysfunction had poorer left ventricular ejection fractions (42% versus 69%), higher indexed left ventricular end-systolic volumes (96 versus 40 mL), and greater indexed left ventricular mass (101 versus 85 g/m(2); P<0.01 for all) than those with normal RV function. Median follow-up was 850 days; 21 of 45 (46.7%) patients with RV dysfunction died, compared with 43 of 145 (29.7%) patients with normal RV function (P=0.035). After adjustment for significant baseline variables, both RV ejection fraction ≤50% (hazard ratio, 2.12; P=0.017) and indexed aortic valve area (hazard ratio, 4.16; P=0.025) were independently associated with survival. RV function, measured on preprocedural CMR, is an independent predictor of mortality after transcatheter aortic valve implantation. CMR assessment of RV function may be important in the risk stratification of patients undergoing transcatheter aortic valve implantation. © 2016 American Heart Association, Inc.
Effect of Age and Renal Function on Survival After Left Ventricular Assist Device Implantation.
Muslem, Rahatullah; Caliskan, Kadir; Akin, Sakir; Yasar, Yunus E; Sharma, Kavita; Gilotra, Nisha A; Kardys, Isabella; Houston, Brian; Whitman, Glenn; Tedford, Ryan J; Hesselink, Dennis A; Bogers, Ad J J C; Manintveld, Olivier C; Russell, Stuart D
2017-12-15
Left ventricular assist devices (LVAD) are increasingly used, especially as destination therapy in in older patients. The aim of this study was to evaluate the effect of age on renal function and mortality in the first year after implantation. A retrospective multicenter cohort study was conducted, evaluating all LVAD patients implanted in the 2 participating centers (age ≥18 years). Patients were stratified according to the age groups <45, 45-54, 55-64, and ≥65 years old. Overall, 241 patients were included (mean age 52.4 ± 12.9 years, 76% males, 33% destination therapy). The mean estimated Glomerular Filtration Rate (eGFR) at 1 year was 85, 72, 69, and 49 mL/min per 1.73 m 2 in the age groups <45(n = 65, 27%), 45-54(n = 52, 22%), 55-64(n = 87, 36%), and ≥65 years (n = 37, 15%) p <0.001)), respectively. Older age and lower eGFR at baseline (p <0.01) were independent predictors of worse renal function at 1 year. The 1-year survival post-implantation was 79%,84%, 68%, and 54% for those in the age group <45, 45-54, 55-64 and ≥65 years (Log-rank p = 0.003). Older age, lower eGFR and, INTERMACS class I were independent predictors of 1-year mortality. Furthermore, older patients (age > 60 years) with an impaired renal function (eGFR <55 mL/min per 1.73 m 2 ) had a 5-fold increased hazard ratio for mortality during the first year after implantation (p <0.001). In conclusion, age >60 years is an independent predictor for an impaired renal function and mortality. Older age combined with reduced renal function pre-implantation had a cumulative adverse effect on survival in patients receiving a LVAD. Copyright © 2017 Elsevier Inc. All rights reserved.
Dailey, Bruno; Jordan, Laurence; Blind, Olivier; Tavernier, Bruno
2009-01-01
The passive fit of a superstructure on implant abutments is essential to success. One source of error when using a tapered cone-screw internal connection may be the difference between the tightening torque level applied to the abutments by the laboratory technician compared to that applied by the treating clinician. The purpose of this study was to measure the axial displacement of tapered cone-screw abutments into implants and their replicas as a function of the tightening torque level. Twenty tapered cone-screw abutments were selected. Two groups were created: 10 abutments were secured into 10 implants, and 10 abutments were secured into 10 corresponding implant replicas. Each abutment was tightened in increasing increments of 5 Ncm, from 0 Ncm to 45 Ncm, with a torque controller. The length of each sample was measured repeatedly with an Electronic Digital Micrometer. The mean axial displacement for the implant group and the replica group was calculated. The data were analyzed by the Mann-Whitney and Spearman tests. For both groups, there was always an axial displacement of the abutment upon each incremental application of torque. The mean axial displacement values varied between 7 and 12 microm for the implant group and between 6 and 21 microm for the replica group at each 5-Ncm increment. From 0 to 45 Ncm, the total mean axial displacement values were 89 microm for the implant group and 122 microm for the replica group. There was a continuous axial displacement of the abutments into implants and implant replicas when the applied torque was raised from 0 to 45 Ncm. Torque applied above the level recommended by the manufacturer increased the difference in displacement between the two groups.
Tribology of alternative bearings.
Fisher, John; Jin, Zhongmin; Tipper, Joanne; Stone, Martin; Ingham, Eileen
2006-12-01
The tribological performance and biological activity of the wear debris produced has been compared for highly cross-linked polyethylene, ceramic-on-ceramic, metal-on-metal, and modified metal bearings in a series of in vitro studies from a single laboratory. The functional lifetime demand of young and active patients is 10-fold greater than the estimated functional lifetime of traditional polyethylene. There is considerable interest in using larger diameter heads in these high demand patients. Highly cross-linked polyethylene show a four-fold reduction in functional biological activity. Ceramic-on-ceramic bearings have the lowest wear rates and least reactive wear debris. The functional biological activity is 20-fold lower than with highly cross-linked polyethylene. Hence, ceramic-on-ceramic bearings address the tribological lifetime demand of highly active patients. Metal-on-metal bearings have substantially lower wear rates than highly cross-linked polyethylene and wear decreases with head diameter. Bedding in wear is also lower with reduced radial clearance. Differential hardness ceramic-on-metal bearings and the application of ceramic-like coatings reduce metal wear and ion levels.
Energy scavenging sources for biomedical sensors.
Romero, E; Warrington, R O; Neuman, M R
2009-09-01
Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limitations due to battery lifetime and size. A trade-off of these two factors has typically governed the size, useful life and capabilities of an autonomous system. Energy generation from sources such as motion, light and temperature gradients has been established as commercially viable alternatives to batteries for human-powered flashlights, solar calculators, radio receivers and thermal-powered wristwatches, among others. Research on energy harvesting from human activities has also addressed the feasibility of powering wearable or implantable systems. Biomedical sensors can take advantage of human-based activities as the energy source for energy scavengers. This review describes the state of the art of energy scavenging technologies for powering sensors and instrumentation of physiological variables. After a short description of the human power and the energy generation limits, the different transduction mechanisms, recent developments and challenges faced are reviewed and discussed.
Amet, Edward M; Uehlein, Chris
2013-12-01
The goal of modern implant dentistry is to return patients to oral health in a rapid and predictable fashion, following a diagnostically driven treatment plan. If only a limited number of implants can be placed, or some fail and the prosthetic phase of implant dentistry is chosen to complete the patient's treatment, the final outcome may result in partial patient satisfaction and is commonly referred to as a "compromise." Previous All-on-4 implant treatment for the patient presented here resulted in a compromise, with an inadequate support system for the mandibular prosthesis and a maxillary complete denture with poor esthetics. The patient was unable to function adequately and also was disappointed with the resulting appearance. Correction of the compromised treatment consisted of bilateral inferior alveolar nerve elevation and repositioning without bone removal for lateral transposition, to gain room for rescue implants for a totally implant-supported and stabilized prosthesis. Treatment time to return the patient to satisfactory comfort, function, facial esthetics, and speech was approximately 2 weeks. The definitive mandibular prosthesis was designed for total implant support and stability with patient retrievability. Adequate space between the mandibular bar system and the soft tissue created a high water bridge effect for self-cleansing. Following a short interim mandibular healing period, the maxillary sinuses were bilaterally grafted to compensate for bone inadequacies and deficiencies for future maxillary implant reconstruction. © 2013 by the American College of Prosthodontists.
Lindeberg, Heli; Burchmore, Richard J S; Kennedy, Malcolm W
2017-03-01
Uterine secretory proteins protect the uterus and conceptuses against infection, facilitate implantation, control cellular damage resulting from implantation, and supply pre-implantation embryos with nutrients. Unlike in humans, the early conceptus of the European polecat ( Mustela putorius ; ferret) grows and develops free in the uterus until implanting at about 12 days after mating. We found that the proteins appearing in polecat uteri changed dramatically with time leading to implantation. Several of these proteins have also been found in pregnant uteri of other eutherian mammals. However, we found a combination of two increasingly abundant proteins that have not been recorded before in pre-placentation uteri. First, the broad-spectrum proteinase inhibitor α 2 -macroglobulin rose to dominate the protein profile by the time of implantation. Its functions may be to limit damage caused by the release of proteinases during implantation or infection, and to control other processes around sites of implantation. Second, lipocalin-1 (also known as tear lipocalin) also increased substantially in concentration. This protein has not previously been recorded as a uterine secretion in pregnancy in any species. If polecat lipocalin-1 has similar biological properties to that of humans, then it may have a combined function in antimicrobial protection and transporting or scavenging lipids. The changes in the uterine secretory protein repertoire of European polecats is therefore unusual, and may be representative of pre-placentation supportive uterine secretions in mustelids (otters, weasels, badgers, mink, wolverines) in general.
Mangano, Francesco; Raspanti, Mario; Maghaireh, Hassan; Mangano, Carlo
2017-12-17
Purpose . The aim of this scanning electron microscope (SEM) study was to investigate the interface between the bone and a novel nanostructured calcium-incorporated dental implant surface in humans. Methods . A dental implant (Anyridge ® , Megagen Implant Co., Gyeongbuk, South Korea) with a nanostructured calcium-incorporated surface (Xpeed ® , Megagen Implant Co., Gyeongbuk, South Korea), which had been placed a month earlier in a fully healed site of the posterior maxilla (#14) of a 48-year-old female patient, and which had been subjected to immediate functional loading, was removed after a traumatic injury. Despite the violent trauma that caused mobilization of the fixture, its surface appeared to be covered by a firmly attached, intact tissue; therefore, it was subjected to SEM examination. The implant surface of an unused nanostructured calcium-incorporated implant was also observed under SEM, as control. Results . The surface of the unused implant showed a highly-structured texture, carved by irregular, multi-scale hollows reminiscent of a fractal structure. It appeared perfectly clean and devoid of any contamination. The human specimen showed trabecular bone firmly anchored to the implant surface, bridging the screw threads and filling the spaces among them. Conclusions . Within the limits of this human histological report, the sample analyzed showed that the nanostructured calcium-incorporated surface was covered by new bone, one month after placement in the posterior maxilla, under an immediate functional loading protocol.
Sun, Xu; Zhai, Jun-Jiang; Liao, Jian; Teng, Min-Hua; Tian, Ai; Liang, Xing
2014-01-01
Objectives: To evaluate masticatory efficiency (ME) and oral health-related quality of life (OHRQoL) in patients rehabilitated with implant-retained mandibular overdentures. Methods: In this randomized controlled clinical trial, 50 edentulous patients visiting the Implant Center and Department of Prosthodontics, West China College of Stomatology, Sichuan University, Chengdu, China between June 2010 and June 2012 were selected and received 2 implant-retained mandibular overdenture treatments. All patients were rehabilitated with maxillary complete dentures. The ME and OHRQoL were determined both one month before the mandibular complete denture was anchored to the osseointegrated implants, and 6 months after anchoring. Paired t-tests were used to compare means of ME, and oral health impact profile-49 (OHIP-49) domains scores between pre- and post-implant. Linear regression models were utilized to seek correlations between ME and OHIP domains scores. Results: The ME increased from pre- to post-implant retained mandibular overdentures significantly (p<0.001). The total OHIP score and 4 subscales scores were changed significantly from pre- to post-implant; namely, functional limitation, psychological discomfort, physical disability, and physical pain. The total OHIP score, functional limitation, physical disability, and physical pain subscale scores were related to ME. Conclusion: Implant-retained mandibular over dentures can significantly improve patients’ ME and OHRQoL. The improvement in OHRQoL is mainly because of the improved ME. An improved chewing experience, and pain relief also contributes to improvement of OHRQoL. PMID:25316463
Osseoperception in Dental Implants: A Systematic Review.
Mishra, Sunil Kumar; Chowdhary, Ramesh; Chrcanovic, Bruno Ramos; Brånemark, Per-Ingvar
2016-04-01
Replacement of lost teeth has significant functional and psychosocial effects. The capability of osseointegrated dental implants to transmit a certain amount of sensibility is still unclear. The phenomenon of developing a certain amount of tactile sensibility through osseointegrated dental implants is called osseoperception. The aim of this article is to evaluate the available literature to find osseoperception associated with dental implants. To identify suitable literature, an electronic search was performed using Medline and PubMed database. Articles published in English and articles whose abstract is available in English were included. The articles included in the review were based on osseoperception, tactile sensation, and neurophysiological mechanoreceptors in relation to dental implants. Articles on peri-implantitis and infection-related sensitivity were not included. Review articles without the original data were excluded, although references to potentially pertinent articles were noted for further follow-up. The phenomenon of osseoperception remains a matter of debate, so the search strategy mainly focused on articles on osseoperception and tactile sensibility of dental implants. This review presents the histological, neurophysiological, and psychophysical evidence of osseoperception and also the role of mechanoreceptors in osseoperception. The literature on osseoperception in dental implants is very scarce. The initial literature search resulted in 90 articles, of which 81 articles that fulfilled the inclusion criteria were included in this systematic review. Patients restored with implant-supported prostheses reported improved tactile and motor function when compared with patients wearing complete dentures. © 2016 by the American College of Prosthodontists.
Intramedullary Mg2Ag nails augment callus formation during fracture healing in mice.
Jähn, Katharina; Saito, Hiroaki; Taipaleenmäki, Hanna; Gasser, Andreas; Hort, Norbert; Feyerabend, Frank; Schlüter, Hartmut; Rueger, Johannes M; Lehmann, Wolfgang; Willumeit-Römer, Regine; Hesse, Eric
2016-05-01
Intramedullary stabilization is frequently used to treat long bone fractures. Implants usually remain unless complications arise. Since implant removal can become technically very challenging with the potential to cause further tissue damage, biodegradable materials are emerging as alternative options. Magnesium (Mg)-based biodegradable implants have a controllable degradation rate and good tissue compatibility, which makes them attractive for musculoskeletal research. Here we report for the first time the implantation of intramedullary nails made of an Mg alloy containing 2% silver (Mg2Ag) into intact and fractured femora of mice. Prior in vitro analyses revealed an inhibitory effect of Mg2Ag degradation products on osteoclast differentiation and function with no impair of osteoblast function. In vivo, Mg2Ag implants degraded under non-fracture and fracture conditions within 210days and 133days, respectively. During fracture repair, osteoblast function and subsequent bone formation were enhanced, while osteoclast activity and bone resorption were decreased, leading to an augmented callus formation. We observed a widening of the femoral shaft under steady state and regenerating conditions, which was at least in part due to an uncoupled bone remodeling. However, Mg2Ag implants did not cause any systemic adverse effects. These data suggest that Mg2Ag implants might be promising for intramedullary fixation of long bone fractures, a novel concept that has to be further investigated in future studies. Biodegradable implants are promising alternatives to standard steel or titanium implants to avoid implant removal after fracture healing. We therefore developed an intramedullary nail using a novel biodegradable magnesium-silver-alloy (Mg2Ag) and investigated the in vitro and in vivo effects of the implants on bone remodeling under steady state and fracture healing conditions in mice. Our results demonstrate that intramedullary Mg2Ag nails degrade in vivo over time without causing adverse effects. Importantly, radiographs, μCT and bone histomorphometry revealed a significant increase in callus size due to an augmented bone formation rate and a reduced bone resorption in fractures supported by Mg2Ag nails, thereby improving bone healing. Thus, intramedullary Mg2Ag nails are promising biomaterials for fracture healing to circumvent implant removal. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Meston, Cindy M.; Lorenz, Tierney A.
2012-01-01
Physiological responses to sexual stimuli may contribute to the increased rate of sexual problems seen in women with childhood sexual abuse (CSA) histories. We compared two physiological stress responses as predictors of sexual function and satisfaction, sympathetic nervous system (SNS) activation and cortisol in women with (CSA, N = 136) and without CSA histories (NSA, N = 102). In CSA survivors, cortisol response to sexual stimuli did not significantly predict sexual functioning; however, in NSA women, cortisol increases were associated with poorer sexual functioning, and decreases with higher functioning. For women with CSA histories, lower SNS activity was associated with poorer sexual functioning. For CSA survivors with low lifetime trauma, lower SNS activity was associated with higher sexual satisfaction; for women with high lifetime trauma, the reverse was true. Decreased SNS activity during sexual stimuli predicted higher sexual functioning in NSA women with low lifetime exposure to traumatic events, but lower sexual functioning in those with high exposure. Differences between women with and without CSA histories in the association between cortisol and SNS response and sexual functioning and satisfaction suggests that CSA causes disruptions in both short and long-term stress responses to sexual stimuli that perpetuate into adulthood. PMID:24748915
Krennmair, Gerald; Seemann, Rudolf; Fazekas, Andres; Ewers, Rolf; Piehslinger, Eva
2012-01-01
To determine patient satisfaction and preference for implant-supported mandibular overdentures (IOD) retained with ball or Locator attachments. In addition, peri-implant conditions and prosthodontic maintenance efforts for the final attachments were evaluated after 1 year of function. In this crossover clinical trial, 20 edentulous patients were recruited to receive two mandibular implants in the canine region and were provided with implant-retained mandibular overdentures and new complete maxillary dentures. Implant-retained mandibular overdentures were stabilized with either ball attachments or Locator attachments, in random order. After 3 months of function, the attachments in the existing denture were changed. Questionnaires on satisfaction/complaints with the prostheses were administered at baseline (with the old dentures) and after 3 months of function with each attachment, thus providing for an intraindividual comparison. The decision for the final attachment chosen was based on the patient's preference. For the definitive attachment, peri-implant conditions (peri-implant marginal bone resorption, pocket depth, and Plaque Index, Gingival Index, and Bleeding Index) as well as prosthodontic maintenance efforts and satisfaction score were evaluated after an insertion period of 1 year. Nineteen (95%) patients completed the study (1 dropout). Patient satisfaction improved significantly (P<.05) from baseline (old dentures) to the new prostheses retained with each of the two attachment types for all domains of satisfaction. However, there were no differences between ball or Locator attachment for any items of satisfaction evaluated and neither attachment had a significant patient preference. No differences for peri-implant parameters or for patient satisfaction were noted between the definitive attachments (ball, n=10; Locator, n=9) after 1 year. Although the overall incidence rate of prosthodontic maintenance did not significantly differ between both retention modalities, the Locator attachment required more postinsertion aftercare (activation of retention) than the ball anchors.
Mordenfeld, Arne; Lindgren, Christer; Hallman, Mats
2016-10-01
Straumann® BoneCeramic™ is a synthetic biphasic calcium phosphate (BCP) aimed for sinus floor augmentation. Long-term follow-up of implants placed in BCP after sinus augmentation is still missing. The primary aim of the study was to compare survival rates and marginal bone loss of Straumann SLActive implants placed in either BCP (test) or Bio-Oss® (DBB) (control) after sinus floor augmentation. The secondary aim was to calculate graft sinus height at different time points. Bilateral sinus floor augmentation was performed in a split mouth model. Eleven patients (mean age 67 years) received 100% BCP on one side and 100% DBB on the contralateral side. After 8 months of graft healing, 62 Straumann SLActive implants were placed. After 5 years of functional loading (6 years after augmentation) of implants, marginal bone levels and grafted sinus height were measured, and implant survival and success rates were calculated. After 5 years of loading, all prosthetic constructions were in function although two implants were lost in each grafting material. The overall implant survival rate was 93.5% (91.7% for BCP, 91.3% for DBB, and 100% for residual bone). The success rates were 83.3% and 91.3% for BCP and DBB, respectively. There was no statistically significant difference in mean marginal bone level after 5 years between BCP (1.4 ± 1.2 mm) and DBB (1.0 ± 0.7 mm). Graft height reduction (GHR) after 6 years was limited to 6.6% for BCP and 5.8% for DBB. In this limited RCT study, the choice of biomaterial used for sinus floor augmentation did not seem to have any impact on survival rates and marginal bone level of the placed implants after 5 years of functional loading and GHR was minimal. © 2015 Wiley Periodicals, Inc.
Cooper, Lyndon F; Stanford, Clark; Feine, Jocelyne; McGuire, Michael
2016-07-01
Single-tooth implant restorations are commonly used to replace anterior maxillary teeth. The esthetic, functional, and biologic outcomes are, in part, a function of the abutment and crown. The purpose of this clinical study was to describe the implant, abutment, and crown survival and complication rates for CAD/CAM zirconia abutment and lithium disilicate crown restorations for single-tooth implants. As part of a broader prospective investigation that enrolled and treated 141 participants comparing tissue responses at the conical interface (CI; AstraTech OsseoSpeed), flat-to-flat interface (FI; NobelSpeedy), and platform-switch interface (PS; NanoTite Certain Prevail) of single-tooth implants, computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia abutments (ATLANTIS Abutment) and cemented lithium disilicate (e.max) crowns were used in the restoration of all implants. After 2.4 years in function (3 years after implant placement), the implant, abutment, and crown of 110 participants were evaluated. Technical and biologic complications were recorded. Demographic results were tabulated as percentages with mean values and standard deviations. Abutment survival was calculated with the Kaplan-Meier method. After 2.4 years, no abutments or crowns had been lost. Abutment complications (screw loosening, screw fracture, fracture) were absent for all 3 implant groups. Crown complications were limited to 2 crowns debonding and 1 with excess cement (2.5%). Five biological complications (4.0%) were recorded. The overall complication rate was 6.5%. CAD/CAM zirconia abutments restored with cemented lithium disilicate crowns demonstrated high survival on 3 different implant-abutment interface designs. No abutment or abutment screw fracture occurred. The technical complications observed after 2.4 years were minor and reversible. The use of CAD/CAM zirconia abutments with cemented lithium disilicate crowns is associated with high technical and biologic success at 2.4 years. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Public perceptions of dental implants: a qualitative study.
Wang, Guihua; Gao, Xiaoli; Lo, Edward C M
2015-07-01
Dental implants have become a popular option for treating partially dentate or edentulous patients. Information on dental implants is widely available in the public domain and is disseminated through industries and dental practitioners at various levels/disciplines. This qualitative study aimed to evaluate the public's information acquisition and their perceptions of dental implants and the effects of these on their care-seeking and decision making. A purposive sample of 28 adults were recruited to join six focus groups. To be eligible, one must be 35-64 years of age, had never been engaged in dentally related jobs, had at least one missing tooth, and had heard about dental implant but never received dental implant or entered into any dental consultation regarding dental implants. All of the focus groups discussions were transcribed verbatim and subjected to thematic content analysis following a grounded theory approach. Participants acquired information on dental implants through various means, such as patient information boards, printed advertisements, social media, and personal connections. They expected dental implants to restore the patients' appearance, functions, and quality of life to absolute normality. They regarded dental implants as a panacea for all cases of missing teeth, overestimated their functions and longevity, and underestimated the expertise needed to carry out the clinical procedures. They were deterred from seeking dental implant treatment by the high price, invasive procedures, risks, and complications. Members of the public were exposed to information of varying quality and had some unrealistic expectations regarding dental implants. Such perceptions may shape their care-seeking behaviours and decision-making processes in one way or another. The views and experiences gathered in this qualitative study could assist clinicians to better understand the public's perspectives, facilitate constructive patient-dentist communication, and contribute to the creation of positive clinical experiences in implant dentistry. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.
Fang, Hui; Zhao, Jianing; Yu, Ki Jun; Song, Enming; Farimani, Amir Barati; Chiang, Chia-Han; Jin, Xin; Xue, Yeguang; Xu, Dong; Du, Wenbo; Seo, Kyung Jin; Zhong, Yiding; Yang, Zijian; Won, Sang Min; Fang, Guanhua; Choi, Seo Woo; Chaudhuri, Santanu; Huang, Yonggang; Alam, Muhammad Ashraful; Viventi, Jonathan; Aluru, N R; Rogers, John A
2016-10-18
Materials that can serve as long-lived barriers to biofluids are essential to the development of any type of chronic electronic implant. Devices such as cardiac pacemakers and cochlear implants use bulk metal or ceramic packages as hermetic enclosures for the electronics. Emerging classes of flexible, biointegrated electronic systems demand similar levels of isolation from biofluids but with thin, compliant films that can simultaneously serve as biointerfaces for sensing and/or actuation while in contact with the soft, curved, and moving surfaces of target organs. This paper introduces a solution to this materials challenge that combines (i) ultrathin, pristine layers of silicon dioxide (SiO 2 ) thermally grown on device-grade silicon wafers, and (ii) processing schemes that allow integration of these materials onto flexible electronic platforms. Accelerated lifetime tests suggest robust barrier characteristics on timescales that approach 70 y, in layers that are sufficiently thin (less than 1 μm) to avoid significant compromises in mechanical flexibility or in electrical interface fidelity. Detailed studies of temperature- and thickness-dependent electrical and physical properties reveal the key characteristics. Molecular simulations highlight essential aspects of the chemistry that governs interactions between the SiO 2 and surrounding water. Examples of use with passive and active components in high-performance flexible electronic devices suggest broad utility in advanced chronic implants.
Modifications of Ti-6Al-4V surfaces by direct-write laser machining of linear grooves
NASA Astrophysics Data System (ADS)
Ulerich, Joseph P.; Ionescu, Lara C.; Chen, Jianbo; Soboyejo, Winston O.; Arnold, Craig B.
2007-02-01
As patients who receive orthopedic implants live longer and opt for surgery at a younger age, the need to extend the in vivo lifetimes of these implants has grown. One approach is to pattern implant surfaces with linear grooves, which elicit a cellular response known as contact guidance. Lasers provide a unique method of generating these surface patterns because they are capable of modifying physical and chemical properties over multiple length scales. In this paper we explore the relationship between surface morphology and laser parameters such as fluence, pulse overlap (translation distance), number of passes, and machining environment. We find that using simple procedures involving multiple passes it is possible to manipulate groove properties such as depth, shape, sub-micron roughness, and chemical composition of the Ti-6Al-4V oxide layer. Finally, we demonstrate this procedure by machining several sets of grooves with the same primary groove parameters but varied secondary characteristics. The significance of the secondary groove characteristics is demonstrated by preliminary cell studies indicating that the grooves exhibit basic features of contact guidance and that the cell proliferation in these grooves are significantly altered despite their similar primary characteristics. With further study it will be possible to use specific laser parameters during groove formation to create optimal physical and chemical properties for improved osseointegration.
Ion Implantation of Perfluoropolyether-Lubricated Surfaces for Improved Tribological Performance
NASA Technical Reports Server (NTRS)
Shogrin, Brad
1998-01-01
For over 30 years, perfluoropolyethers (PFPE's) have been the liquid lubricants of choice for space applications because of their proven tribological performance and desirable properties, such as low vapor pressure and a wide liquid temperature range. These oils are used in such space mechanisms as gyroscopes, scanning mirrors, actuators, and filter wheels. In the past few years, there have been several incidents during which PFPE-lubricated space mechanisms have shown anomalous behavior. These anomalies are thought to be the result of PFPE degradation. Investigative research focused on understanding and modeling the degradation of PFPE lubricants has shown that PFPE's degrade and lose their desirable properties while under boundary-lubricated, sliding/rolling contacts and at elevated temperatures. These performance deficiencies are strongly dependent on the surface chemistry and reactivity of the lubricated contacts, which dictate the formation of harmful catalytic by-products. One way to inhibit tribo-induced degradation may be to use passivated surfaces that do not promote the formation of harmful by-products. Such a passivated surface would inhibit PFPE degradation and increase the lifetime of the lubricated mechanism. Ion implantation is one such passivation technique. This surface-treatment technique can modify the surface properties of materials without affecting either the properties or dimensions of the bulk material beneath the treated layer. By introducing a foreign species into a submicron surface layer, ion implantation can induce unique surface microstructures.
NASA Astrophysics Data System (ADS)
Lee, Heui Chang; Ejserholm, Fredrik; Gaire, Janak; Currlin, Seth; Schouenborg, Jens; Wallman, Lars; Bengtsson, Martin; Park, Kinam; Otto, Kevin J.
2017-06-01
Objective. Flexible neural probes are hypothesized to reduce the chronic foreign body response (FBR) mainly by reducing the strain-stress caused by an interplay between the tethered probe and the brain’s micromotion. However, a large discrepancy of Young’s modulus still exists (3-6 orders of magnitude) between the flexible probes and the brain tissue. This raises the question of whether we need to bridge this gap; would increasing the probe flexibility proportionally reduce the FBR? Approach. Using novel off-stoichiometry thiol-enes-epoxy (OSTE+) polymer probes developed in our previous work, we quantitatively evaluated the FBR to four types of probes with different softness: silicon (~150 GPa), polyimide (1.5 GPa), OSTE+Hard (300 MPa), and OSTE+Soft (6 MPa). Main results. We observed a significant reduction in the fluorescence intensity of biomarkers for activated microglia/macrophages and blood-brain barrier (BBB) leakiness around the three soft polymer probes compared to the silicon probe, both at 4 weeks and 8 weeks post-implantation. However, we did not observe any consistent differences in the biomarkers among the polymer probes. Significance. The results suggest that the mechanical compliance of neural probes can mediate the degree of FBR, but its impact diminishes after a hypothetical threshold level. This infers that resolving the mechanical mismatch alone has a limited effect on improving the lifetime of neural implants.
Cui, Zhiwei; Tian, Yi-Xing; Yue, Wen; Yang, Lei; Li, Qunyang
2016-01-01
Artificial total hip arthroplasty (THA) is one of the most effective orthopaedic surgeries that has been used for decades. However, wear of the articulating surfaces is one of the key failure causes limiting the lifetime of total hip implant. In this paper, Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) were employed to explore the composition and formation mechanism of the tribo-layer on the articulating surfaces of metal-on-polyethylene (MoPE) implants retrieved from patients. Results showed that, in contrast to conventional understanding, the attached tribo-layer contained not only denatured proteins but also a fraction of polymer particles. The formation of the tribo-layer was believed to relate to lubrication regime, which was supposed to be largely affected by the nature of the ultra-high-molecule-weight-polyethylene (UHMWPE). Wear and formation of tribo-layer could be minimized in elasto-hydrodynamic lubrication (EHL) regime when the UHMWPE was less stiff and have a morphology containing micro-pits; whereas the wear was more severe and tribo-layer formed in boundary lubrication. Our results and analyses suggest that enhancing interface lubrication may be more effective on reducing wear than increasing the hardness of material. This finding may shed light on the design strategy of artificial hip joints. PMID:27345704
NASA Astrophysics Data System (ADS)
Cui, Zhiwei; Tian, Yi-Xing; Yue, Wen; Yang, Lei; Li, Qunyang
2016-06-01
Artificial total hip arthroplasty (THA) is one of the most effective orthopaedic surgeries that has been used for decades. However, wear of the articulating surfaces is one of the key failure causes limiting the lifetime of total hip implant. In this paper, Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) were employed to explore the composition and formation mechanism of the tribo-layer on the articulating surfaces of metal-on-polyethylene (MoPE) implants retrieved from patients. Results showed that, in contrast to conventional understanding, the attached tribo-layer contained not only denatured proteins but also a fraction of polymer particles. The formation of the tribo-layer was believed to relate to lubrication regime, which was supposed to be largely affected by the nature of the ultra-high-molecule-weight-polyethylene (UHMWPE). Wear and formation of tribo-layer could be minimized in elasto-hydrodynamic lubrication (EHL) regime when the UHMWPE was less stiff and have a morphology containing micro-pits; whereas the wear was more severe and tribo-layer formed in boundary lubrication. Our results and analyses suggest that enhancing interface lubrication may be more effective on reducing wear than increasing the hardness of material. This finding may shed light on the design strategy of artificial hip joints.
Fang, Hui; Yu, Ki Jun; Song, Enming; Farimani, Amir Barati; Chiang, Chia-Han; Jin, Xin; Xu, Dong; Du, Wenbo; Seo, Kyung Jin; Zhong, Yiding; Yang, Zijian; Won, Sang Min; Fang, Guanhua; Choi, Seo Woo; Chaudhuri, Santanu; Huang, Yonggang; Alam, Muhammad Ashraful; Viventi, Jonathan; Aluru, N. R.; Rogers, John A.
2016-01-01
Materials that can serve as long-lived barriers to biofluids are essential to the development of any type of chronic electronic implant. Devices such as cardiac pacemakers and cochlear implants use bulk metal or ceramic packages as hermetic enclosures for the electronics. Emerging classes of flexible, biointegrated electronic systems demand similar levels of isolation from biofluids but with thin, compliant films that can simultaneously serve as biointerfaces for sensing and/or actuation while in contact with the soft, curved, and moving surfaces of target organs. This paper introduces a solution to this materials challenge that combines (i) ultrathin, pristine layers of silicon dioxide (SiO2) thermally grown on device-grade silicon wafers, and (ii) processing schemes that allow integration of these materials onto flexible electronic platforms. Accelerated lifetime tests suggest robust barrier characteristics on timescales that approach 70 y, in layers that are sufficiently thin (less than 1 μm) to avoid significant compromises in mechanical flexibility or in electrical interface fidelity. Detailed studies of temperature- and thickness-dependent electrical and physical properties reveal the key characteristics. Molecular simulations highlight essential aspects of the chemistry that governs interactions between the SiO2 and surrounding water. Examples of use with passive and active components in high-performance flexible electronic devices suggest broad utility in advanced chronic implants. PMID:27791052
NASA Astrophysics Data System (ADS)
Coskun, Ulas C.; Lam, Sandra; Sun, Yuansheng; Liao, Shih-Chu Jeff; George, Steven C.; Barbieri, Beniamino
2017-02-01
Phosphorescence probes can have significantly long lifetimes, on the order of micro- to milli-seconds or longer. In addition, environmental changes can affect the lifetimes of these phosphorescence probes. Thus, Phosphorescence Lifetime Imaging Microscopy (PLIM) is a very useful tool to localize the phosphorescence probes based on their lifetimes to study the variance in the lifetimes due to the micro environmental changes. Since the probes respond to the biologically relevant parameters like oxygen concentration, they can be used to study various biologically relevant processes like cellular metabolism, protein interaction etc. In this case, we study the effects of oxygen on Oxyphor G4 with PLIM. Since The Oxyphor G4 can be quenched by O2, it is a good example of such a probe and has a lifetime around 250us. Here we present the digital frequency domain PLIM technique and study the lifetime of the Oxyphor G4 as a function of the O2 concentration. The lifetime data are successfully presented in a phasor plot for various O2 concentrations and are consistent with the time domain data. Overall, we can analyze the oxygen consumption of varying cells using this technique.
Mann, Kenneth A; Miller, Mark A; Goodheart, Jacklyn R; Izant, Timothy H; Cleary, Richard J
2014-03-01
Biological adaptation following placement of a total knee replacements (TKRs) affects peri-implant bone mineral density (BMD) and implant fixation. We quantified the proximal tibial bone strain and implant-bone micro-motion for functioning postmortem retrieved TKRs and assessed the strain/micro-motion relationships with chronological (donor age and time in service) and patient (body weight and BMD) factors. Twenty-two tibial constructs were functionally loaded to one body weight (60% medial/40% lateral), and the bone strains and tray/bone micro-motions were measured using a digital image correlation system. Donors with more time in service had higher bone strains (p = 0.044), but there was not a significant (p = 0.333) contribution from donor age. Donors with lower peri-implant BMD (p = 0.0039) and higher body weight (p = 0.0286) had higher bone strains. Long term implants (>11 years) had proximal bone strains 900 µϵ that were almost twice as high as short term (<5 years) implants 570 µϵ. Micro-motion was greater for younger donors (p = 0.0161) and longer time in service (p = 0.0008). Increased bone strain with long term in vivo service could contribute to loosening of TKRs by failure of the tibial peri-implant bone. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Samberg, Meghan E.; Cohen, Paul H.; Wysk, Richard A.; Monteiro-Riviere, Nancy A.
2012-01-01
Nanomaterials play a significant role in biomedical research and applications due to their unique biological, mechanical, and electrical properties. In recent years, they have been utilised to improve the functionality and reliability of a wide range of implantable medical devices ranging from well-established orthopaedic residual hardware devices (e.g. hip implants) that can repair defects in skeletal systems to emerging tissue engineering scaffolds that can repair or replace organ functions. This review summarizes the applications and efficacies of these nanomaterials that include synthetic or naturally occurring metals, polymers, ceramics, and composites in orthopaedic implants, the largest market segment of implantable medical devices. The importance of synergistic engineering techniques that can augment or enhance the performance of nanomaterial applications in orthopaedic implants is also discussed,, the focus being on a low intensity direct electric current (LIDC) stimulation technology to promote the long-term antibacterial efficacy of oligodynamic metal-based surfaces by ionization, while potentially accelerating tissue growth and osseointegration. While many nanomaterials have clearly demonstrated their ability to provide more effective implantable medical surfaces, further decisive investigations are necessary before they can translate into medically safe and commercially viable clinical applications. The paper concludes with a discussion about some of the critical impending issues with the application of nanomaterials-based technologies in implantable medical devices, and potential directions to address these. PMID:23335493
Immediate implants placed into infected sockets: a case report with 3-year follow-up.
Naves, Marina de Melo; Horbylon, Bruna Zacharias; Gomes, Camila de Freitas; Menezes, Helder Henrique Machado de; Bataglion, César; Magalhães, Denildo de
2009-01-01
The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.
NASA Astrophysics Data System (ADS)
Wang, Chun; Brunton, Emma; Haghgooie, Saman; Cassells, Kahli; Lowery, Arthur; Rajan, Ramesh
2013-08-01
Objective. Cortical neural prostheses with implanted electrode arrays have been used to restore compromised brain functions but concerns remain regarding their long-term stability and functional performance. Approach. Here we report changes in electrode impedance and stimulation thresholds for a custom-designed electrode array implanted in rat motor cortex for up to three months. Main Results. The array comprises four 2000 µm long electrodes with a large annular stimulating surface (7860-15700 µm2) displaced from the penetrating insulated tip. Compared to pre-implantation in vitro values there were three phases of impedance change: (1) an immediate large increase of impedance by an average of two-fold on implantation; (2) a period of continued impedance increase, albeit with considerable variability, which reached a peak at approximately four weeks post-implantation and remained high over the next two weeks; (3) finally, a period of 5-6 weeks when impedance stabilized at levels close to those seen immediately post-implantation. Impedance could often be temporarily decreased by applying brief trains of current stimulation, used to evoke motor output. The stimulation threshold to induce observable motor behaviour was generally between 75-100 µA, with charge density varying from 48-128 µC cm-2, consistent with the lower current density generated by electrodes with larger stimulating surface area. No systematic change in thresholds occurred over time, suggesting that device functionality was not compromised by the factors that caused changes in electrode impedance. Significance. The present results provide support for the use of annulus electrodes in future applications in cortical neural prostheses.
Sarı, Cenk; Baştuğ, Serdal; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Akçay, Murat; Aslan, Abdullah Nabi; Bayram, Nihal Akar; Bozkurt, Engin
2015-01-01
Introduction Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. Aim We want to share our experience with transcatheter aortic valve implantation in patients with a preexisting functional mitral valve prosthesis and describe a series of important technical and pre-procedural details. Material and methods At our center, 135 patients with symptomatic severe aortic stenosis were treated with transcatheter aortic valve implantation. Six of them with a preexisting mitral valve prosthesis received an Edwards SAPIEN XT valve through the transfemoral route. Results Transcatheter aortic valve implantation was performed successfully in all 6 patients without any deformation of the cobalt-chromium/steel stents of the aortic valve bioprosthesis. Also no distortion or malfunction in the mitral valve prosthesis was observed after the procedure. There were no complications during the hospitalization period. Post-procedural echocardiography revealed no or mild aortic paravalvular regurgitation and normal valve function in all the patients. In addition, serial echocardiographic examination demonstrated that both the stability and function of the aortic and mitral prosthetic valves were normal without any deterioration in the gradients and the degree of the regurgitation at long-term follow-ups. Conclusions Our experience confirms that transcatheter aortic valve implantation is technically feasible in patients with previous mitral valve replacement but comprehensive evaluation of patients by multimodal imaging techniques such as transesophageal echocardiography and multislice computed tomography is mandatory for a successful and safe procedure. PMID:26677380
Cheng, Ying; Ren, Mingming; Niu, Yanyan; Qiao, Jianhua; Aneba, S; Chorvat, D; Chorvatova, A
2009-12-01
The primary function of cardiac mitochondria is the production of ATP to support heart contraction. Examination of the mitochondrial redox state is therefore crucially important to sensitively detect early signs of mitochondrial function in pathophysiological conditions, such as ischemia, diabetes and heart failure. We study fingerprinting of mitochondrial metabolic oxidative state in living cardiomyocytes with spectrally-resolved fluorescence lifetime spectroscopy of NAD(P)H, the principal electron donor in mitochondrial respiration responsible for vital ATP supply. Here NAD(P)H is studied as a marker for non-invasive fluorescent probing of the mitochondrial function. NAD(P) H fluorescence is recorded in cardiac cells following excitation with 375nm UV-light and detection by spectrally-resolved time-correlated single photon counting (TCSPC), based on the simultaneous measurement of the fluorescence spectra and fluorescence lifetimes. Modulation of NADH production and/or mitochondrial respiration is tested to study dynamic characteristics of NAD(P) H fluorescence decay. Our results show that at least a 3-exponential decay model, with 0.4-0.7ns, 1.2-1.9ns and 8.0-13. Ons lifetime pools is necessary to describe cardiomyocyte autofluorescence (AF) within 420-560nm spectral range. Increased mitochondrial NADH production by ketone bodies enhanced the fluorescence intensity, without significant change in fluorescent lifetimes. Rotenone, the inhibitor of Complex I of the mitochondrial respiratory chain, increased AF intensity and shortened the average fluorescence lifetime. Dinitrophenol (DNP), an uncoupling agent of the mitochondrial oxidative phosphorylation, lowered AF intensity, broadened the spectral shoulder at 520 nm and increased the average fluorescence lifetime. These effects are comparable to the study of NADH fluorescence decay in vitro. In the present contribution we demonstrated that spectrally-resolved fluorescence lifetime technique provides promising new tool for analysis of mitochondrial NAD(P) H fluorescence with good reproducibility in living cardiomyocytes. This approach will enhance our knowledge about cardiomyocyte oxidative metabolism and/or its dysfunction at a cellular level. In the future, this approach can prove helpful in the clinical diagnosis and treatment of mitochondrial disorder.
Surgical and Technical Modalities for Hearing Restoration in Ear Malformations.
Dazert, Stefan; Thomas, Jan Peter; Volkenstein, Stefan
2015-12-01
Malformations of the external and middle ear often go along with an aesthetic and functional handicap. Independent of additional aesthetic procedures, a successful functional hearing restoration leads to a tremendous gain in quality of life for affected patients. The introduction of implantable hearing systems (bone conduction and middle ear devices) offers new therapeutic options in this field. We focus on functional rehabilitation of patients with malformations, either by surgical reconstruction or the use of different implantable hearing devices, depending on the disease itself and the severity of malformation as well as hearing impairment. Patients with an open ear canal and minor malformations are good candidates for surgical hearing restoration of middle ear structures with passive titanium or autologous implants. In cases with complete fibrous or bony atresia of the ear canal, the most promising functional outcome and gain in quality of life can be expected with an active middle ear implant or a bone conduction device combined with a surgical aesthetic rehabilitation in a single or multi-step procedure. Although the surgical procedure for bone conduction devices is straightforward and safe, more sophisticated operations for active middle ear implants (e.g., Vibrant Soundbridge, MED-EL, Innsbruck, Austria) provide an improved speech discrimination in noise and the ability of sound localization compared with bone conduction devices where the stimulation reaches both cochleae. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, Thomas J.; Myjak, Mitchell J.
At the request of the U.S. Army Corps of Engineers, Portland District, researchers from Pacific Northwest National Laboratory investigated the use of an application-specific integrated circuit (ASIC) to reduce the weight and volume of Juvenile Salmon Acoustic Telemetry System (JSATS) transmitters while retaining current functionality. Review of the design of current JSATS transmitters identified components that could be replaced by an ASIC while retaining the function of the current transmitter and offering opportunities to extend function if desired. ASIC design alternatives were identified that could meet transmitter weight and volume targets of 200 mg and 100 mm3. If alternatives tomore » the cylindrical batteries used in current JSATS transmitters can be identified, it could be possible to implant ASIC-based JSATS transmitters by injection rather than surgery. Using criteria for the size of fish suitable for surgical implantation of current JSATS transmitters, it was concluded that fish as small as 70 mm in length could be implanted with an ASIC-based transmitter, particularly if implantation by injection became feasible.« less
Gervais, Pauline; Hébert, Réjean; Lamontagne, Julie; Tousignant, Michel
2011-12-01
The objectives of the study were to identify the adjustments made during the implantation and the conditions favouring or limiting the SMAF utilisation. A multiqualitative quote was developed. The Functional autonomy measurement system (SMAF) was implanted in 11 French medico-social establishments. Analyses were made with the mixed type thematic method from Miles and Huberman. Principal adjustments that have been made during implantation concern the informatics assistance and clinical support. Strategic, organizational and individual factors explained adhesion level of actors and the subsequent flow of implantation. Establishment of SMAF and of the software eSMAF® in the medico-social establishments rests on a certain number of conditions which could be identified during the study. These conditions made it possible to work out structured recommendations for future implementations.
Moisture dependence of positron lifetime in Kevlar-49
NASA Technical Reports Server (NTRS)
Singh, Jag J.; Holt, William H.; Mock, Willis, Jr.
1984-01-01
Because of filamentary character of Kevlar-49 aramid fibers, there is some concern about the moisture uptake and its effect on plastic composites reinforced with Kevlar-49 fibers. As part of continuing studies of positron lifetime in polymers, we have measured positron lifetime spectra in Kevlar-49 fibers as a function of their moisture content. The long lifetime component intensities are rather low, being only of the order of 2-3 percent. The measured values of long component lifetimes at various moisture levels in the specimens are as follows: 2072 +/- 173 ps (dry); 2013 +/- 193 ps (20.7 percent saturation); 1665 +/- 85 ps (25.7 percent saturation); 1745 +/- 257 ps (32.1 percent saturation); and 1772 +/- 217 ps (100 percent saturation). It is apparent that the long component lifetime at first decreases and then increases as the specimen moisture content increases. These results have been compared with those inferred from Epon-815 and Epon-815/K-49 composite data.
Sweat, Noah W; Bates, Larry W; Hendricks, Peter S
2016-01-01
Developing methods for improving creativity is of broad interest. Classic psychedelics may enhance creativity; however, the underlying mechanisms of action are unknown. This study was designed to assess whether a relationship exists between naturalistic classic psychedelic use and heightened creative problem-solving ability and if so, whether this is mediated by lifetime mystical experience. Participants (N = 68) completed a survey battery assessing lifetime mystical experience and circumstances surrounding the most memorable experience. They were then administered a functional fixedness task in which faster completion times indicate greater creative problem-solving ability. Participants reporting classic psychedelic use concurrent with mystical experience (n = 11) exhibited significantly faster times on the functional fixedness task (Cohen's d = -.87; large effect) and significantly greater lifetime mystical experience (Cohen's d = .93; large effect) than participants not reporting classic psychedelic use concurrent with mystical experience. However, lifetime mystical experience was unrelated to completion times on the functional fixedness task (standardized β = -.06), and was therefore not a significant mediator. Classic psychedelic use may increase creativity independent of its effects on mystical experience. Maximizing the likelihood of mystical experience may need not be a goal of psychedelic interventions designed to boost creativity.
Guo, Wenzhong; Hong, Wei; Zhang, Bin; Chen, Yuzhong; Xiong, Naixue
2014-01-01
Mobile security is one of the most fundamental problems in Wireless Sensor Networks (WSNs). The data transmission path will be compromised for some disabled nodes. To construct a secure and reliable network, designing an adaptive route strategy which optimizes energy consumption and network lifetime of the aggregation cost is of great importance. In this paper, we address the reliable data aggregation route problem for WSNs. Firstly, to ensure nodes work properly, we propose a data aggregation route algorithm which improves the energy efficiency in the WSN. The construction process achieved through discrete particle swarm optimization (DPSO) saves node energy costs. Then, to balance the network load and establish a reliable network, an adaptive route algorithm with the minimal energy and the maximum lifetime is proposed. Since it is a non-linear constrained multi-objective optimization problem, in this paper we propose a DPSO with the multi-objective fitness function combined with the phenotype sharing function and penalty function to find available routes. Experimental results show that compared with other tree routing algorithms our algorithm can effectively reduce energy consumption and trade off energy consumption and network lifetime. PMID:25215944
Verbal Processing Speed and Executive Functioning in Long-Term Cochlear Implant Users
ERIC Educational Resources Information Center
AuBuchon, Angela M.; Pisoni, David B.; Kronenberger, William G.
2015-01-01
Purpose: The purpose of this study was to report how "verbal rehearsal speed" (VRS), a form of covert speech used to maintain verbal information in working memory, and another verbal processing speed measure, perceptual encoding speed, are related to 3 domains of executive function (EF) at risk in cochlear implant (CI) users: verbal…
Lee, Ga Yeon; Park, Sung-Ji; Kim, Sujin; Choi, Namgyung; Jeong, Dong Seop; Jeon, Eun-Seok; Lee, Young Tak
2014-01-01
Left ventricular assist device (LVAD) is a good treatment option for the patients ineligible for cardiac transplantation. Several studies have demonstrated that a ventricular assist device improves the quality of life and prognosis of the patients with end-stage heart failure. A 75-yr-old man debilitated with New York Heart Association (NYHA) functional class III-IV due to severe left ventricular systolic dysfunction received LVAD implantation as a destination therapy. The patient was discharged with improved functional status (NYHA functional class II) after appropriate cardiac rehabilitation and education about how to manage the device and potential emergency situations. This is the first case of successful continuous-flow LVAD implantation as a destination therapy in Korea.
Societal and Family Lifetime Cost of Dementia: Implications for Policy.
Jutkowitz, Eric; Kane, Robert L; Gaugler, Joseph E; MacLehose, Richard F; Dowd, Bryan; Kuntz, Karen M
2017-10-01
To estimate the cost of dementia and the extra cost of caring for someone with dementia over the cost of caring for someone without dementia. We developed an evidence-based mathematical model to simulate disease progression for newly diagnosed individuals with dementia. Data-driven trajectories of cognition, function, and behavioral and psychological symptoms were used to model disease progression and predict costs. Using modeling, we evaluated lifetime and annual costs of individuals with dementia, compared costs of those with and without clinical features of dementia, and evaluated the effect of reducing functional decline or behavioral and psychological symptoms by 10% for 12 months (implemented when Mini-Mental State Examination score ≤21). Mathematical model. Representative simulated U.S. incident dementia cases. Value of informal care, out-of-pocket expenditures, Medicaid expenditures, and Medicare expenditures. From time of diagnosis (mean age 83), discounted total lifetime cost of care for a person with dementia was $321,780 (2015 dollars). Families incurred 70% of the total cost burden ($225,140), Medicaid accounted for 14% ($44,090), and Medicare accounted for 16% ($52,540). Costs for a person with dementia over a lifetime were $184,500 greater (86% incurred by families) than for someone without dementia. Total annual cost peaked at $89,000, and net cost peaked at $72,400. Reducing functional decline or behavioral and psychological symptoms by 10% resulted in $3,880 and $680 lower lifetime costs than natural disease progression. Dementia substantially increases lifetime costs of care. Long-lasting, effective interventions are needed to support families because they incur the most dementia cost. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.
Influence of ion-implanted profiles on the performance of GaAs MESFET's and MMIC amplifiers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pavlidis, D.; Cazaux, J.L.; Graffeuil, J.
1988-04-01
The RF small-signal performance of GaAs MESFET's and MMIC amplifiers as a function of various ion-implanted profiles is theoretically and experimentally investigated. Implantation energy, dose, and recess depth influence are theoretically analyzed with the help of a specially developed device simulator. The performance of MMIC amplifiers processed with various energies, doses, recess depths, and bias conditions is discussed and compared to experimental characteristics. Some criteria are finally proposed for the choice of implantation conditions and process in order to optimize the characteristics of ion-implanted FET's and to realize process-tolerant MMIC amplifiers.
Phacoemulsification and implantation of an accommodating IOL after PRK.
Aslanides, loannis M; Plainis, Sotiris; Kumar, Vinod; Ginis, Harilaos
2006-01-01
To present a case of phacoemulsification and implantation of an accommodating intraocular lens (IOL) in a patient with cataract formation after previous refractive surgery. A 50-year-old man, who initially had photorefractive keratectomy to correct moderate myopia, developed a cataract in one eye. He subsequently underwent phacoemulsification and implantation of a 1CU accommodating IOL, as he wished to remain spectacle independent. The patient's distance vision was fully restored. However, accommodative function, which was assessed using subjective and novice objective techniques, was only partially restored. Although the accommodating IOL fully restored the patient's distance vision, accommodative function was only partially restored.
Kitterick, Padraig; DeBold, Lisa; Weal, Mark; Clarke, Nicholas; Newberry, Eva; Aubert, Lisa
2016-01-01
Introduction Many resources are required to provide postoperative care to patients who receive a cochlear implant. The implant service commits to lifetime follow-up. The patient commits to regular adjustment and rehabilitation appointments in the first year and annual follow-up appointments thereafter. Offering remote follow-up may result in more stable hearing, reduced patient travel expense, time and disruption, more empowered patients, greater equality in service delivery and more freedom to optimise the allocation of clinic resources. Methods and analysis This will be a two-arm feasibility randomised controlled trial (RCT) involving 60 adults using cochlear implants with at least 6 months device experience in a 6-month clinical trial of remote care. This project will design, implement and evaluate a person-centred long-term follow-up pathway for people using cochlear implants offering a triple approach of remote and self-monitoring, self-adjustment of device and a personalised online support tool for home speech recognition testing, information, self-rehabilitation, advice, equipment training and troubleshooting. The main outcome measure is patient activation. Secondary outcomes are stability and quality of hearing, stability of quality of life, clinic resources, patient and clinician experience, and any adverse events associated with remote care. We will examine the acceptability of remote care to service users and clinicians, the willingness of participants to be randomised, and attrition rates. We will estimate numbers required to plan a fully powered RCT. Ethics and dissemination Ethical approval was received from North West—Greater Manchester South Research Ethics Committee (15/NW/0860) and the University of Southampton Research Governance Office (ERGO 15329). Results Results will be disseminated in the clinical and scientific communities and also to the patient population via peer-reviewed research publications both online and in print, conference and meeting presentations, posters, newsletter articles, website reports and social media. Trial registration number ISRCTN14644286; Pre-results. PMID:27178980
Cost-Utility Analysis of Cochlear Implantation in Australian Adults.
Foteff, Chris; Kennedy, Steven; Milton, Abul Hasnat; Deger, Melike; Payk, Florian; Sanderson, Georgina
2016-06-01
Sequential and simultaneous bilateral cochlear implants are emerging as appropriate treatment options for Australian adults with sensory deficits in both cochleae. Current funding of Australian public hospitals does not provide for simultaneous bilateral cochlear implantation (CI) as a separate surgical procedure. Previous cost-effectiveness studies of sequential and simultaneous bilateral CI assumed 100% of unilaterally treated patients' transition to a sequential bilateral CI. This assumption does not place cochlear implantation in the context of the generally treated population. When mutually exclusive treatment options exist, such as unilateral CI, sequential bilateral CI, and simultaneous bilateral CI, the mean costs of the treated populations are weighted in the calculation of incremental cost-utility ratios. The objective was to evaluate the cost-utility of bilateral hearing aids (HAs) compared with unilateral, sequential, and simultaneous bilateral CI in Australian adults with bilateral severe to profound sensorineural hearing loss. Cost-utility analysis of secondary sources input to a Markov model. Australian health care perspective, lifetime horizon with costs and outcomes discounted 5% annually. Bilateral HAs as treatment for bilateral severe to profound sensorineural hearing loss compared with unilateral, sequential, and simultaneous bilateral CI. Incremental costs per quality adjusted life year (AUD/QALY). When compared with bilateral hearing aids the incremental cost-utility ratio for the CI treatment population was AUD11,160/QALY. The incremental cost-utility ratio was weighted according to the number of patients treated unilaterally, sequentially, and simultaneously, as these were mutually exclusive treatment options. No peer-reviewed articles have reported the incremental analysis of cochlear implantation in a continuum of care for surgically treated populations with bilateral severe to profound sensorineural hearing loss. Unilateral, sequential, and simultaneous bilateral CI were cost-effective when compared with bilateral hearing aids. Technologies that reduce the total number of visits for a patient could introduce additional cost efficiencies into clinical practice.
Microfluidic Actuation of Carbon Nanotube Fibers for Neural Recordings
NASA Astrophysics Data System (ADS)
Vercosa, Daniel G.
Implantable devices to record and stimulate neural circuits have led to breakthroughs in neuroscience; however, technologies capable of electrical recording at the cellular level typically rely on rigid metals that poorly match the mechanical properties of soft brain tissue. As a result these electrodes often cause extensive acute and chronic injury, leading to short electrode lifetime. Recently, flexible electrodes such as Carbon Nanotube fibers (CNTf) have emerged as an attractive alternative to conventional electrodes and studies have shown that these flexible electrodes reduce neuro-inflammation and increase the quality and longevity of neural recordings. Insertion of these new compliant electrodes, however, remains challenge. The stiffening agents necessary to make the electrodes rigid enough to be inserted increases device footprint, which exacerbates brain damage during implantation. To overcome this challenge we have developed a novel technology to precisely implant and actuate high-performance, flexible carbon nanotube fiber (CNTf) microelectrodes without using a stiffening agents or shuttles. Instead, our technology uses drag forces within a microfluidic device to drive electrodes into tissue while minimizing the amount of fluid that is ejected into the tissue. In vitro experiments in brain phantoms, show that microfluidic actuated CNTf can be implanted at least 4.5 mm depth with 30 microm precision, while keeping the total volume of fluid ejected below 0.1 microL. As proof of concept, we inserted CNTfs in the small cnidarian Hydra littoralis and observed compound action potentials corresponding to contractions and in agreement with the literature. Additionally, brain slices extracted from transgenic mice were used to show that our device can be used to record spontaneous and light evoked activity from the cortex and deep brain regions such as the thalamic reticular nucleus (TRN). Overall our microfluidic actuation technology provides a platform for implanting and actuating flexible electrodes that significantly reduces damage during insertion.
Integrating Microtissues in Nanofiber Scaffolds for Regenerative Nanomedicine
Keller, Laetitia; Wagner, Quentin; Offner, Damien; Eap, Sandy; Musset, Anne-Marie; Arruebo, Manuel; Kelm, Jens M.; Schwinté, Pascale; Benkirane-Jessel, Nadia
2015-01-01
A new generation of biomaterials focus on smart materials incorporating cells. Here, we describe a novel generation of synthetic nanofibrous implant functionalized with living microtissues for regenerative nanomedicine. The strategy designed here enhances the effectiveness of therapeutic implants compared to current approaches used in the clinic today based on single cells added to the implant. PMID:28793604
Jarvis, J C; Salmons, S
2001-01-01
The design of an implantable neuromuscular stimulator represents a trade-off in which the desire to maximise functionality and operational life competes with the need for the implanted device to be small, reliable, safe, and easy to use. In this introduction and overview we consider the basic problems and the different approaches to their solution.
Zimel, Melissa N; Farfalli, German L; Zindman, Alexandra M; Riedel, Elyn R; Morris, Carol D; Boland, Patrick J; Healey, John H
2016-02-01
Patients with failed distal femoral megaprostheses often have bone loss that limits reconstructive options and contributes to the high failure rate of revision surgery. The Compress(®) Compliant Pre-stress (CPS) implant can reconstruct the femur even when there is little remaining bone. It differs from traditional stemmed prostheses because it requires only 4 to 8 cm of residual bone for fixation. Given the poor long-term results of stemmed revision constructs, we sought to determine the failure rate and functional outcomes of the CPS implant in revision surgery. (1) What is the cumulative incidence of mechanical and other types of implant failure when used to revise failed distal femoral arthroplasties placed after oncologic resection? (2) What complications are characteristic of this prosthesis? (3) What function do patients achieve after receiving this prosthesis? We retrospectively reviewed 27 patients who experienced failure of a distal femoral prosthesis and were revised to a CPS implant from April 2000 to February 2013. Indications for use included a minimum 2.5 mm cortical thickness of the remaining proximal femur, no prior radiation, life expectancy > 10 years, and compliance with protected weightbearing for 3 months. The cumulative incidence of failure was calculated for both mechanical (loss of compression between the implant anchor plug and spindle) and other failure modes using a competing risk analysis. Failure was defined as removal of the CPS implant. Followup was a minimum of 2 years or until implant removal. Median followup for patients with successful revision arthroplasty was 90 months (range, 24-181 months). Functional outcomes were measured with the Musculoskeletal Tumor Society (MSTS) functional assessment score. The cumulative incidence of mechanical failure was 11% (95% confidence interval [CI], 4%-33%) at both 5 and 10 years. These failures occurred early at a median of 5 months. The cumulative incidence of other failures was 18% (95% CI, 7%-45%) at 5 and 10 years, all of which were deep infection. Three patients required secondary operations for cortical insufficiency proximal to the anchor plug in bone not spanned by the CPS implant and unrelated to the prosthesis. Median MSTS score was 27 (range, 24-30). Revision distal femoral replacement arthroplasty after a failed megaprosthesis is often difficult as a result of a lack of adequate bone. Reconstruction with the CPS implant has an 11% failure rate at 10 years. Our results are promising and demonstrate the durable fixation provided by the CPS implant. Further studies to compare the CPS prosthesis and other reconstruction options with respect to survival and functional outcomes are warranted. Level IV, therapeutic study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schrof, Julian, E-mail: julian.schrof@ise.fraunhofer.de; Müller, Ralph; Benick, Jan
2015-07-28
Boron diffusivity reduction in extrinsically doped silicon was investigated in the context of a process combination consisting of BBr{sub 3} furnace diffusion and preceding Phosphorus ion implantation. The implantation of Phosphorus leads to a substantial blocking of Boron during the subsequent Boron diffusion. First, the influences of ion implantation induced point defects as well as the initial P doping on B diffusivity were studied independently. Here, it was found that not the defects created during ion implantation but the P doping itself results in the observed B diffusion retardation. The influence of the initial P concentration was investigated in moremore » detail by varying the P implantation dose. A secondary ion mass spectrometry (SIMS) analysis of the BSG layer after the B diffusion revealed that the B diffusion retardation is not due to potential P content in the BSG layer but rather caused by the n-type doping of the crystalline silicon itself. Based on the observations the B diffusion retardation was classified into three groups: (i) no reduction of B diffusivity, (ii) reduced B diffusivity, and (iii) blocking of the B diffusion. The retardation of B diffusion can well be explained by the phosphorus doping level resulting in a Fermi level shift and pairing of B and P ions, both reducing the B diffusivity. Besides these main influences, there are probably additional transient phenomena responsible for the blocking of boron. Those might be an interstitial transport mechanism caused by P diffusion that reduces interstitial concentration at the surface or the silicon/BSG interface shift due to oxidation during the BBr{sub 3} diffusion process. Lifetime measurements revealed that the residual (non-blocked) B leads to an increased dark saturation current density in the P doped region. Nevertheless, electrical quality is on a high level and was further increased by reducing the B dose as well as by removing the first few nanometers of the silicon surface after the BBr{sub 3} diffusion.« less
Potential of Wake-Up Radio-Based MAC Protocols for Implantable Body Sensor Networks (IBSN)—A Survey
Karuppiah Ramachandran, Vignesh Raja; Ayele, Eyuel D.; Meratnia, Nirvana; Havinga, Paul J. M.
2016-01-01
With the advent of nano-technology, medical sensors and devices are becoming highly miniaturized. Consequently, the number of sensors and medical devices being implanted to accurately monitor and diagnose a disease is increasing. By measuring the symptoms and controlling a medical device as close as possible to the source, these implantable devices are able to save lives. A wireless link between medical sensors and implantable medical devices is essential in the case of closed-loop medical devices, in which symptoms of the diseases are monitored by sensors that are not placed in close proximity of the therapeutic device. Medium Access Control (MAC) is crucial to make it possible for several medical devices to communicate using a shared wireless medium in such a way that minimum delay, maximum throughput, and increased network life-time are guaranteed. To guarantee this Quality of Service (QoS), the MAC protocols control the main sources of limited resource wastage, namely the idle-listening, packet collisions, over-hearing, and packet loss. Traditional MAC protocols designed for body sensor networks are not directly applicable to Implantable Body Sensor Networks (IBSN) because of the dynamic nature of the radio channel within the human body and the strict QoS requirements of IBSN applications. Although numerous MAC protocols are available in the literature, the majority of them are designed for Body Sensor Network (BSN) and Wireless Sensor Network (WSN). To the best of our knowledge, there is so far no research paper that explores the impact of these MAC protocols specifically for IBSN. MAC protocols designed for implantable devices are still in their infancy and one of their most challenging objectives is to be ultra-low-power. One of the technological solutions to achieve this objective so is to integrate the concept of Wake-up radio (WuR) into the MAC design. In this survey, we present a taxonomy of MAC protocols based on their use of WuR technology and identify their bottlenecks to be used in IBSN applications. Furthermore, we present a number of open research challenges and requirements for designing an energy-efficient and reliable wireless communication protocol for IBSN. PMID:27916822
Potential of Wake-Up Radio-Based MAC Protocols for Implantable Body Sensor Networks (IBSN)-A Survey.
Karuppiah Ramachandran, Vignesh Raja; Ayele, Eyuel D; Meratnia, Nirvana; Havinga, Paul J M
2016-11-29
With the advent of nano-technology, medical sensors and devices are becoming highly miniaturized. Consequently, the number of sensors and medical devices being implanted to accurately monitor and diagnose a disease is increasing. By measuring the symptoms and controlling a medical device as close as possible to the source, these implantable devices are able to save lives. A wireless link between medical sensors and implantable medical devices is essential in the case of closed-loop medical devices, in which symptoms of the diseases are monitored by sensors that are not placed in close proximity of the therapeutic device. Medium Access Control (MAC) is crucial to make it possible for several medical devices to communicate using a shared wireless medium in such a way that minimum delay, maximum throughput, and increased network life-time are guaranteed. To guarantee this Quality of Service (QoS), the MAC protocols control the main sources of limited resource wastage, namely the idle-listening, packet collisions, over-hearing, and packet loss. Traditional MAC protocols designed for body sensor networks are not directly applicable to Implantable Body Sensor Networks (IBSN) because of the dynamic nature of the radio channel within the human body and the strict QoS requirements of IBSN applications. Although numerous MAC protocols are available in the literature, the majority of them are designed for Body Sensor Network (BSN) and Wireless Sensor Network (WSN). To the best of our knowledge, there is so far no research paper that explores the impact of these MAC protocols specifically for IBSN. MAC protocols designed for implantable devices are still in their infancy and one of their most challenging objectives is to be ultra-low-power. One of the technological solutions to achieve this objective so is to integrate the concept of Wake-up radio (WuR) into the MAC design. In this survey, we present a taxonomy of MAC protocols based on their use of WuR technology and identify their bottlenecks to be used in IBSN applications. Furthermore, we present a number of open research challenges and requirements for designing an energy-efficient and reliable wireless communication protocol for IBSN.
Baumhauer, Judith F; Singh, Dishan; Glazebrook, Mark; Blundell, Chris; De Vries, Gwyneth; Le, Ian L D; Nielsen, Dominic; Pedersen, M Elizabeth; Sakellariou, Anthony; Solan, Matthew; Wansbrough, Guy; Younger, Alastair S E; Daniels, Timothy
2016-05-01
Although a variety of great toe implants have been tried in an attempt to maintain toe motion, the majority have failed with loosening, malalignment/dislocation, implant fragmentation and bone loss. In these cases, salvage to arthrodesis is more complicated and results in shortening of the ray or requires structural bone graft to reestablish length. This prospective study compared the efficacy and safety of this small (8/10 mm) hydrogel implant to the gold standard of a great toe arthrodesis for advanced-stage hallux rigidus. In this prospective, randomized non-inferiority study, patients from 12 centers in Canada and the United Kingdom were randomized (2:1) to a synthetic cartilage implant or first metatarsophalangeal (MTP) joint arthrodesis. VAS pain scale, validated outcome measures (Foot and Ankle Ability Measure [FAAM] sport scale), great toe active dorsiflexion motion, secondary procedures, radiographic assessment, and safety parameters were evaluated. Analysis was performed using intent-to-treat (ITT) and modified ITT (mITT) methodology. The primary endpoint for the study consisted of a single composite endpoint using the 3 primary study outcomes (pain, function, and safety). The individual subject's outcome was considered a success if all of the following criteria were met: (1) improvement (decrease) from baseline in VAS pain of ≥30% at 12 months; (2) maintenance of function from baseline in FAAM sports subscore at 12 months; and (3) absence of major safety events at 2 years. The proportion of successes in each group was determined and 1-sided 95% confidence interval for the difference between treatment groups was calculated. Noninferiority of the implant to arthrodesis was considered statistically significant if the 1-sided 95% lower confidence interval was greater than the equivalence limit (<15%). A total of 236 patients were initially enrolled; 17 patients withdrew prior to randomization, 17 patients withdrew after randomization, and 22 were nonrandomized training patients, leaving 152 implant and 50 arthrodesis patients. Standard demographics and baseline outcomes were similar for both groups. VAS pain scores decreased significantly in both the implant and arthrodesis groups from baseline at 12 and 24 months. Similarly, the FAAM sports and activity of daily living subscores improved significantly at 12 and 24 months in both groups. First MTP active dorsiflexion motion improvement was 6.2 degrees (27.3%) after implant placement and was maintained at 24 months. Subsequent secondary surgeries occurred in 17 (11.2%) implant patients (17 procedures) and 6 (12.0%) arthrodesis patients (7 procedures). Fourteen (9.2%) implants were removed and converted to arthrodesis, and 6 (12.0%) arthrodesis patients (7 procedures [14%]) had isolated screws or plate and screw removal. There were no cases of implant fragmentation, wear, or bone loss. When analyzing the ITT and mITT population for the primary composite outcome of VAS pain, function (FAAM sports), and safety, there was statistical equivalence between the implant and arthrodesis groups. A prospective, randomized (2:1), controlled, noninferiority clinical trial was performed to compare the safety and efficacy of a small synthetic cartilage bone implant to first MTP arthrodesis in patients with advanced-stage hallux rigidus. This study showed equivalent pain relief and functional outcomes. The synthetic implant was an excellent alternative to arthrodesis in patients who wished to maintain first MTP motion. The percentage of secondary surgical procedures was similar between groups. Less than 10% of the implant group required revision to arthrodesis at 2 years. Level I, prospective randomized study. © The Author(s) 2016.
Biology of teeth and implants: Host factors - pathology, regeneration, and the role of stem cells.
Eggert, F-Michael; Levin, Liran
2018-01-01
In chronic periodontitis and peri-implantitis, cells of the innate and adaptive immune systems are involved directly in the lesions within the tissues of the patient. Absence of a periodontal ligament around implants does not prevent a biologic process similar to that of periodontitis from affecting osseointegration. Our first focus is on factors in the biology of individuals that are responsible for the susceptibility of such individuals to chronic periodontitis and to peri-implantitis. Genetic factors are of significant importance in susceptibility to these diseases. Genetic factors of the host affect the composition of the oral microbiome in the same manner that they influence other microbiomes, such as those of the intestines and of the lungs. Our second focus is on the central role of stem cells in tissue regeneration, in the functioning of innate and adaptive immune systems, and in metabolism of bone. Epithelial cell rests of Malassez (ERM) are stem cells of epithelial origin that maintain the periodontal ligament as well as the cementum and alveolar bone associated with the ligament. The tissue niche within which ERM are found extends into the supracrestal areas of collagen fiber-containing tissues of the gingivae above the bony alveolar crest. Maintenance and regeneration of all periodontal tissues involves the activity of a variety of stem cells. The success of dental implants indicates that important groups of stem cells in the periodontium are active to enable that biologic success. Successful replantation of avulsed teeth and auto-transplantation of teeth is comparable to placing dental implants, and so must also involve periodontal stem cells. Biology of teeth and biology of implants represents the biology of the various stem cells that inhabit specialized niches within the periodontal tissues. Diverse biologic processes must function together successfully to maintain periodontal health. Osseointegration of dental implants does not involve formation of cementum or collagen fibers inserted into cementum - indicating that some stem cells are not active around dental implants or their niches are not available. Investigation of these similarities and differences between teeth and implants will help to develop a better understanding of the biology and physiologic functioning of the periodontium.
NH2+ implantations induced superior hemocompatibility of carbon nanotubes.
Guo, Meixian; Li, Dejun; Zhao, Mengli; Zhang, Yiteng; Deng, Xiangyun; Geng, Dongsheng; Li, Ruying; Sun, Xueliang; Gu, Hanqing; Wan, Rongxin
2013-05-01
NH2+ implantation was performed on multiwalled carbon nanotubes (MWCNTs) prepared by chemical vapor deposition. The hemocompatibility of MWCNTs and NH2+-implanted MWCNTs was evaluated based on in vitro hemolysis, platelet adhesion, and kinetic-clotting tests. Compared with MWCNTs, NH2+-implanted MWCNTs displayed more perfect platelets and red blood cells in morphology, lower platelet adhesion rate, lower hemolytic rate, and longer kinetic blood-clotting time. NH2+-implanted MWCNTs with higher fluency of 1 × 1016 ions/cm2 led to the best thromboresistance, hence desired hemocompatibility. Fourier transfer infrared and X-ray photoelectron spectroscopy analyses showed that NH2+ implantation caused the cleavage of some pendants and the formation of some new N-containing functional groups. These results were responsible for the enhanced hemocompatibility of NH2+-implanted MWCNTs.
Moberly, Aaron C; Harris, Michael S; Boyce, Lauren; Nittrouer, Susan
2017-04-14
Models of speech recognition suggest that "top-down" linguistic and cognitive functions, such as use of phonotactic constraints and working memory, facilitate recognition under conditions of degradation, such as in noise. The question addressed in this study was what happens to these functions when a listener who has experienced years of hearing loss obtains a cochlear implant. Thirty adults with cochlear implants and 30 age-matched controls with age-normal hearing underwent testing of verbal working memory using digit span and serial recall of words. Phonological capacities were assessed using a lexical decision task and nonword repetition. Recognition of words in sentences in speech-shaped noise was measured. Implant users had only slightly poorer working memory accuracy than did controls and only on serial recall of words; however, phonological sensitivity was highly impaired. Working memory did not facilitate speech recognition in noise for either group. Phonological sensitivity predicted sentence recognition for implant users but not for listeners with normal hearing. Clinical speech recognition outcomes for adult implant users relate to the ability of these users to process phonological information. Results suggest that phonological capacities may serve as potential clinical targets through rehabilitative training. Such novel interventions may be particularly helpful for older adult implant users.
Harris, Michael S.; Boyce, Lauren; Nittrouer, Susan
2017-01-01
Purpose Models of speech recognition suggest that “top-down” linguistic and cognitive functions, such as use of phonotactic constraints and working memory, facilitate recognition under conditions of degradation, such as in noise. The question addressed in this study was what happens to these functions when a listener who has experienced years of hearing loss obtains a cochlear implant. Method Thirty adults with cochlear implants and 30 age-matched controls with age-normal hearing underwent testing of verbal working memory using digit span and serial recall of words. Phonological capacities were assessed using a lexical decision task and nonword repetition. Recognition of words in sentences in speech-shaped noise was measured. Results Implant users had only slightly poorer working memory accuracy than did controls and only on serial recall of words; however, phonological sensitivity was highly impaired. Working memory did not facilitate speech recognition in noise for either group. Phonological sensitivity predicted sentence recognition for implant users but not for listeners with normal hearing. Conclusion Clinical speech recognition outcomes for adult implant users relate to the ability of these users to process phonological information. Results suggest that phonological capacities may serve as potential clinical targets through rehabilitative training. Such novel interventions may be particularly helpful for older adult implant users. PMID:28384805
Asgharzadeh Shirazi, H; Ayatollahi, M R; Asnafi, A
2017-05-01
In a dental implant system, the value of stress and its distribution plays a pivotal role on the strength, durability and life of the implant-bone system. A typical implant consists of a Titanium core and a thin layer of biocompatible material such as the hydroxyapatite. This coating has a wide range of clinical applications in orthopedics and dentistry due to its biocompatibility and bioactivity characteristics. Low bonding strength and sudden variation of mechanical properties between the coating and the metallic layers are the main disadvantages of such common implants. To overcome these problems, a radial distributed functionally graded biomaterial (FGBM) was proposed in this paper and the effect of material property on the stress distribution around the dental implant-bone interface was studied. A three-dimensional finite element simulation was used to illustrate how the use of radial FGBM dental implant can reduce the maximum von Mises stress and, also the stress shielding effect in both the cortical and cancellous bones. The results, of course, give anybody an idea about optimized behaviors that can be achieved using such materials. The finite element solver was validated by familiar methods and the results were compared to previous works in the literature.
Badar, Muhammad; Lünsdorf, Heinrich; Evertz, Florian; Rahim, Muhammad Imran; Glasmacher, Birgit; Hauser, Hansjörg; Mueller, Peter P
2013-07-01
Magnesium alloys have been proposed as prospective degradable implant materials. To elucidate the complex interactions between the corroding implants and the tissue, magnesium implants were analyzed in a mouse model and the response was compared to that induced by Ti and by the resorbable polymer polyglactin, respectively. One month after implantation, distinct traces of corrosion were apparent but the magnesium implants were still intact, whereas resorbable polymeric wound suture implants were already fragmented. Analysis of magnesium implants 2weeks after implantation by energy-dispersive X-ray spectroscopy indicated that magnesium, oxygen, calcium and phosphate were present at the implant surface. One month after implantation, the element composition of the outermost layer of the implant was indicative of tissue without detectable levels of magnesium, indicating a protective barrier function of this organic layer. In agreement with this notion, gene expression patterns in the surrounding tissue were highly similar for all implant materials investigated. However, high-resolution imaging using energy-filtered transmission electron microscopy revealed magnesium-containing microparticles in the tissue in the proximity of the implant. The release of such corrosion particles may contribute to the accumulation of calcium phosphate in the nearby tissue and to bone conductive activities of magnesium implants. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Speirs, M; Van Hooreweder, B; Van Humbeeck, J; Kruth, J-P
2017-06-01
Selective laser melting (SLM) is an additive manufacturing technique able to produce complex functional parts via successively melting layers of metal powder. This process grants the freedom to design highly complex scaffold components to allow bone ingrowth and aid mechanical anchorage. This paper investigates the compression fatigue behaviour of three different unit cells (octahedron, cellular gyroid and sheet gyroid) of SLM nitinol scaffolds. It was found that triply periodic minimal surfaces display superior static mechanical properties in comparison to conventional octahedron beam lattice structures at identical volume fractions. Fatigue resistance was also found to be highly geometry dependent due to the effects of AM processing techniques on the surface topography and notch sensitivity. Geometries minimising nodal points and the staircase effect displayed the greatest fatigue resistance when normalized to yield strength. Furthermore oxygen analysis showed a large oxygen uptake during SLM processing which must be altered to meet ASTM medical grade standards and may significantly reduce fatigue life. These achieved fatigue properties indicate that NiTi scaffolds produced via SLM can provide sufficient mechanical support over an implants lifetime within stress range values experienced in real life. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chamerski, Kordian; Stopa, Marcin; Jelen, Piotr; Lesniak, Magdalena; Sitarz, Maciej; Filipecki, Jacek
2018-03-01
Silicone oil is the one of the artificial materials used in vitreoretinal surgery for retinal detachment treatment. Since the silicone oil is sometimes applied along with intraocular lens (IOL) implantation the direct influence of silicone oil on the artificial implant should be taken into account. Presented study was performed in order to determine the time-dependent impact of silicone oil on hydrogel based ophthalmic materials. Two kinds of IOLs based on hydroxyethyl 2-methacrylate (HEMA) hydrogel material were immersed in silicone oil based on linear poly(dimethylsiloxane) (PDMS). Incubation in oil medium was performed in 37 °C for 1, 3 and 6 months. After appropriate period of the incubation samples were examined by means of FTIR-ATR method as the technique of surface study as well as Positron Annihilation Lifetime Spectroscopy (PALS) as the method of internal structure investigation. Results obtained during the study revealed that silicone oil is not capable to penetrate the internal structure of investigated materials and its impact has come down to interaction with the samples surfaces only.
Long-Term Biostability of Self-Assembling Protein Polymers in the Absence of Covalent Crosslinking
Sallach, Rory E.; Cui, Wanxing; Balderrama, Fanor; Martinez, Adam W.; Wen, Jing; Haller, Carolyn A.; Taylor, Jeannette V.; Wright, Elizabeth R.; Long, Robert C.; Chaikof, Elliot L.
2009-01-01
Unless chemically crosslinked, matrix proteins, such as collagen or silk, display a limited lifetime in vivo with significant degradation observed over a period of weeks. Likewise, amphiphilic peptides, lipopeptides, or glycolipids that self-assemble through hydrophobic interactions to form thin films, fiber networks, or vesicles do not demonstrate in vivo biostability beyond a few days. We report herein that a self-assembling, recombinant elastin-mimetic triblock copolymer elicited minimal inflammatory response and displayed robust in vivo stability for periods exceeding 1 year, in the absence of either chemical or ionic crosslinking. Specifically, neither a significant inflammatory response nor calcification was observed upon implantation of test materials into the peritoneal cavity or subcutaneous space of a mouse model. Moreover, serial quantitative magnetic resonance imaging, evaluation of pre- and post-explant ultrastructure by cryo-high resolution scanning electron microscopy, and an examination of implant mechanical responses revealed substantial preservation of form, material architecture, and biomechanical properties, providing convincing evidence of a non-chemically or ionically crosslinked protein polymer system that exhibits long-term stability in vivo. PMID:19854505
Tissue response to aqueous drainage in a functioning Molteno implant.
Loeffler, K U; Jay, J L
1988-01-01
The tissue reaction to a functioning Molteno implant has been studied by light microscopy and by scanning and transmission electron microscopy. The material was obtained from an aphakic 83-year-old human eye which required enucleation because of intractable bullous keratopathy, despite well controlled intraocular pressure. The tissue response around the silicone rubber tube was that of simple fibroblastic activity. Around the implant, however, there was fibrous tissue in which necrotic cell debris was prominent. No significant inflammation was observed in this tissue, but the choroid beneath the implant showed a focal inflammatory cell infiltrate. The morphology suggests that the tissue around all surfaces of the implant (450 mm2) is exposed to aqueous, which seems to have a toxic effect on the encapsulating connective tissue. The changes seen in the tissue exposed to draining aqueous are similar to those described in experimental studies of the effect of aqueous on cell growth in tissue culture. Images PMID:3342217
Correlation of CsK2Sb photocathode lifetime with antimony thickness
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mamun, M. A.; Hernandez-Garcia, C.; Poelker, M.
CsK2Sb photocathodes with quantum efficiency on the order of 10% at 532 nm, and lifetime greater than 90 days at low voltage, were successfully manufactured via co-deposition of alkali species emanating from an effusion source. Photocathodes were characterized as a function of antimony layer thickness and alkali consumption, inside a vacuum chamber that was initially baked, but frequently vented without re-baking. Photocathode lifetime measured at low voltage is correlated with the antimony layer thickness. Photocathodes manufactured with comparatively thick antimony layers exhibited the best lifetime. We speculate that the antimony layer serves as a reservoir, or sponge, for the alkali.
Zhang, Li; Zhou, Qing; Song, Wen; Wu, Kaimin; Zhang, Yumei; Zhao, Yimin
2017-10-11
Surface functionalization by small interfering RNA (siRNA) is a novel strategy for improved implant osseointegration. A gene delivery system with safety and high transfection activity is a crucial factor for an siRNA-functionalized implant to exert its biological function. To this end, polyethylene glycol (PEG) and polyethylenimine (PEI) dual-functionalized graphene oxide (GO; nGO-PEG-PEI) may present a promising siRNA vector. In this study, nanosized nGO-PEG-PEI was prepared and optimized for siRNA delivery. Titania nanotubes (NTs) fabricated by anodic oxidation were biomodified with nGO-PEG-PEI/siRNA by cathodic electrodeposition, designated as NT-GPP/siRNA. NT-GPP/siRNA possessed benign cytocompatibility, as evaluated by cell adhesion and proliferation. Cellular uptake and knockdown efficiency of the NT-GPP/siRNA were assessed by MC3T3-E1 cells, which exhibited high siRNA delivery efficiency and sustained target gene silencing. Casein kinase-2 interacting protein-1 (Ckip-1) is a negative regulator of bone formation. siRNA-targeting Ckip-1 (siCkip-1) was introduced to the implant, and a series of in vitro and in vivo experiments were carried out to evaluate the osteogenic capacity of NT-GPP/siCkip-1. NT-GPP/siCkip-1 dramatically improved the in vitro osteogenic differentiation of MC3T3-E1 cells in terms of improved osteogenesis-related gene expression, and increased alkaline phosphatase (ALP) production, collagen secretion, and extracellular matrix (ECM) mineralization. Moreover, NT-GPP/siCkip-1 led to apparently enhanced in vivo osseointegration, as indicated by histological staining and EDX line scanning. Collectively, these findings suggest that NT-GPP/siRNA represents a practicable and promising approach for implant functionalization, showing clinical potential for dental and orthopedic applications.
DLTPulseGenerator: A library for the simulation of lifetime spectra based on detector-output pulses
NASA Astrophysics Data System (ADS)
Petschke, Danny; Staab, Torsten E. M.
2018-01-01
The quantitative analysis of lifetime spectra relevant in both life and materials sciences presents one of the ill-posed inverse problems and, hence, leads to most stringent requirements on the hardware specifications and the analysis algorithms. Here we present DLTPulseGenerator, a library written in native C++ 11, which provides a simulation of lifetime spectra according to the measurement setup. The simulation is based on pairs of non-TTL detector output-pulses. Those pulses require the Constant Fraction Principle (CFD) for the determination of the exact timing signal and, thus, the calculation of the time difference i.e. the lifetime. To verify the functionality, simulation results were compared to experimentally obtained data using Positron Annihilation Lifetime Spectroscopy (PALS) on pure tin.
Functionally graded bioactive coatings: From fabrication to testing
NASA Astrophysics Data System (ADS)
Foppiano, Silvia
Every year about half a million Americans undergo total joint replacement surgery of some kind. This number is expected to steadily increase in the future. About 20% of these patients will need a revision surgery because of implant failure, with a significant increase in health care cost. Current implant materials for load bearing applications must be strong enough to support the loads involved in daily activities, and bioinert, to limit reactivity in the body that may cause inflammatory and other adverse reactions. Metal alloys are typically used as materials for load bearing implants and rely on mechanical interlocking to achieve fixation which can be improved by using bone cements. To improve implant osteointegration, metal implants have been coated with a bone-like mineral: hydroxyapatite (HA). The plasma spray technique is commonly used to apply the HA coating. Such implants do not require the use of bone cement. Plasma sprayed HA coated implants are FDA approved and currently on the market, but their properties are not reproducible or reliable. Thus, coating delamination can occur. Our research group developed a novel family of bioactive glasses which were enameled onto titanium alloy using a functionally graded approach. We stratified the coating with different glass compositions to fulfill different functions. We coupled a first glass layer, with a good CTE match to the alloy, with a second layer of bioactive glass obtaining a functionally graded bioactive coating (FGC). In this thesis for the first time the cytocompatibility of novel bioactive glasses, and their functionally graded coatings on Ti6Al4V, was studied with an in vitro bone model (MC3T3-E1.4 mouse preosteblast cells). The novel bioactive glasses are cytocompatible and no compositional change is required. The fabrication process is reproducible, introduces a small (average 6 vol%) amount of crystallization, which does not significantly affect bioactivity in SBF as tested. The coatings are cytocompatible, but should be preconditioned in SBF prior to their use. Preconditioning stabilizes the coatings, eliminates possible contaminants introduced during processing and handling, and yields dissolution products capable of inducing specific gene expression (e.g. Runx-2). Future research will involve identification of such dissolution products as well as in vivo testing.
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management. PMID:15247993
Zwaan, Jakob; Vanden Bogaerde, Leonardo; Sahlin, Herman; Sennerby, Lars
2016-01-01
Purpose: To study the clinical/radiographic outcomes and stability of a tapered implant design with a hydrophilic surface when placed in the maxilla using various protocols and followed for one year. Methods: Ninety-seven consecutive patients treated as part of daily routine in two clinics with 163 tapered implants in healed sites, in extraction sockets and together with bone augmentation procedures in the maxilla were evaluated after one year in function. Individual healing periods varying from 0 to 6 months had been used. Insertion torque (IT) and resonance frequency analysis (RFA) measurements were made at baseline. Follow-up RFA registrations were made after 6 and 12 months of loading. The marginal bone levels were measured in intraoral radiographs from baseline and after 12 months. A reference group consisting of 163 consecutive straight maxillary implants was used for the comparison of baseline IT and RFA measurements. Results: Five implants failed before loading, giving an implant survival rate of 96.9% and a prosthesis survival rate of 99.4% after one year. The mean marginal bone loss after one year was 0.5 mm (SD 0.4). The mean IT was statistically significantly higher for tapered than for straight reference implants (41.3 ± 12.0 Ncm vs 33.6 ± 12.5 Ncm, p < 0.001). The tapered implants showed a statistically insignificantly higher mean ISQ value than the straight references implants (73.7 ± 6.4 ISQ vs 72.2 ± 8.0 ISQ, p=0.119). There was no correlation between IT and marginal bone loss. There was a correlation between IT and RFA measurements (p < 0.001). Conclusion: The tapered implant showed a high survival rate and minimal marginal bone loss after one year in function when using various protocols for placement. The tapered implant showed significantly higher insertion torque values than straight reference implants. PMID:28077972
A Glucose Fuel Cell for Implantable Brain–Machine Interfaces
Rapoport, Benjamin I.; Kedzierski, Jakub T.; Sarpeshkar, Rahul
2012-01-01
We have developed an implantable fuel cell that generates power through glucose oxidation, producing steady-state power and up to peak power. The fuel cell is manufactured using a novel approach, employing semiconductor fabrication techniques, and is therefore well suited for manufacture together with integrated circuits on a single silicon wafer. Thus, it can help enable implantable microelectronic systems with long-lifetime power sources that harvest energy from their surrounds. The fuel reactions are mediated by robust, solid state catalysts. Glucose is oxidized at the nanostructured surface of an activated platinum anode. Oxygen is reduced to water at the surface of a self-assembled network of single-walled carbon nanotubes, embedded in a Nafion film that forms the cathode and is exposed to the biological environment. The catalytic electrodes are separated by a Nafion membrane. The availability of fuel cell reactants, oxygen and glucose, only as a mixture in the physiologic environment, has traditionally posed a design challenge: Net current production requires oxidation and reduction to occur separately and selectively at the anode and cathode, respectively, to prevent electrochemical short circuits. Our fuel cell is configured in a half-open geometry that shields the anode while exposing the cathode, resulting in an oxygen gradient that strongly favors oxygen reduction at the cathode. Glucose reaches the shielded anode by diffusing through the nanotube mesh, which does not catalyze glucose oxidation, and the Nafion layers, which are permeable to small neutral and cationic species. We demonstrate computationally that the natural recirculation of cerebrospinal fluid around the human brain theoretically permits glucose energy harvesting at a rate on the order of at least 1 mW with no adverse physiologic effects. Low-power brain–machine interfaces can thus potentially benefit from having their implanted units powered or recharged by glucose fuel cells. PMID:22719888
De Faveri, Sara; Maggiolini, Emma; Miele, Ermanno; De Angelis, Francesco; Cesca, Fabrizia; Benfenati, Fabio; Fadiga, Luciano
2014-01-01
The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes – over time – compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses. PMID:24782757
Nickenig, Hans-Joachim; Wichmann, Manfred; Happe, Arndt; Zöller, Joachim E; Eitner, Stephan
2013-10-01
The purpose of this split-mouth study was to compare macro- and microstructure implant surfaces at the marginal bone level over five years of functional loading. From January to February 2006, 133 implants (70 rough-surfaced microthreaded implants and 63 machined-neck implants) were inserted in the mandible of 34 patients with Kennedy Class I residual dentitions and followed until December 2011. Marginal bone level was radiographically determined at six time points: implant placement (baseline), after the healing period, after six months, and at two years, three years, and five years follow-up. Median follow-up time was 5.2 years (range: 5.1-5.4). The machined-neck group had a mean crestal bone loss of 0.5 mm (0.0-2.3) after the healing period, 1.1 mm (0.0-3.0) at two years follow-up, and 1.4 mm (0.0-2.9) at five years follow-up. The rough-surfaced microthreaded implant group had a mean bone loss of 0.1 mm (-0.4 to 2.0) after the healing period, 0.5 mm (0.0-2.1) at two years follow-up, and 0.7 mm (0.0-2.3) at five years follow-up. The two implant types showed significant differences in marginal bone levels. Rough-surfaced microthreaded design caused significantly less loss of crestal bone levels under long-term functional loading in the mandible when compared to machined-neck implants. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Cakir, Onur; Kazancioglu, Hakki Oguz; Celik, Gozde; Deger, Sabire; Ak, Gulsum
2014-07-01
The aim of this study was to compare the satisfaction and quality of life (QoL) in a group of patients using mandibular complete dentures, implant-retained overdentures, removable partial dentures (RPDs), or implant-supported fixed partial dentures (FPDs). A total of 116 patients (aged 36 to 81, mean age 58 ± 10.03 years) were assigned to four groups (n = 29) and treated with mandibular implant-retained overdentures, implant-supported FPDs (two implants/three unit FPDs), conventional complete dentures, or RPDs. The groups were well matched in terms of gender, age, and the edentulous period. All patients had edentulous maxillary arches and completely or partially edentulous mandibles. All prostheses were mandibular prostheses. The OHIP-14, OHQoL-UK, and SF-36 surveys were used to determine QoL before implant surgery and 1 year after prosthetic treatment. The baseline and 1-year data from 116 patients were analyzed. A significant improvement was found among the QoL scales for all groups (p < 0.05). The most significant improvement was found in the implant-retained overdenture group (15.67 ± 2.47), while the least improvement was found among the implant-supported FPD group (5.14 ± 2.08). The SF-36 test revealed no differences between the before and after treatment scores for general health, pain, vitality, social function, and physical function difficulties (p > 0.05). The only significant difference was found for mental health (p = 0.011). A positive influence on oral health-related QoL was observed in all groups. The QoL values were the most improved in the implant-retained overdenture group. © 2014 by the American College of Prosthodontists.
Functionalization of titanium dioxide nanotubes with biomolecules for biomedical applications.
Oliveira, Weslley F; Arruda, Isabel R S; Silva, Germana M M; Machado, Giovanna; Coelho, Luana C B B; Correia, Maria T S
2017-12-01
Titanium (Ti) and its alloys are extensively used in the manufacture of implants because they have biocompatibility. The production of a nanostructured surface can be achieved by means of titanium dioxide nanotubes (TNTs) which can have dimensions equivalent to the nanometric components of human bone, in addition to increasing the efficiency of such implants. The search is ongoing for ways to improve the performance of these TNTs in terms of their functionalization through coating these nanotubular matrices with biomolecules. The biocompatibility of the functionalized TNTs can be improved by promoting rapid osseointegration, by preventing the adhesion of bacteria on such surfaces and/or by promoting a more sustained local release of drugs that are loaded into such TNTs. In addition to the implants, these nanotubular matrices have been used in the manufacture of high-performance biosensors capable of immobilizing principally enzymes on their surfaces, which has possible use in disease diagnosis. The objective of this review is to show the main techniques of immobilization of biomolecules in TNTs, evidencing the most recent applications of bioactive molecules that have been functionalized in the nanotubular matrices for use in implants and biosensors. This surveillance also proposes a new class of biomolecules that can be used to functionalize these nanostructured surfaces, lectins. Copyright © 2017 Elsevier B.V. All rights reserved.
Guan, Binbin; Wang, Haorong; Xu, Ruiqing; Zheng, Guoying; Yang, Jie; Liu, Zihao; Cao, Man; Wu, Mingyao; Song, Jinhua; Li, Neng; Li, Ting; Cai, Qing; Yang, Xiaoping; Li, Yanqiu; Zhang, Xu
2016-01-01
Direct metal laser sintering is a technology that allows the fabrication of titanium (Ti) implants with a functional gradation of porosity and surface roughness according to three-dimensional (3D) computer data. The surface roughness of direct metal laser sintered titanium (DMLS-Ti) implants may provide abundant binding sites for bacteria. Bacterial colonization and subsequent biofilm formation can cause unsatisfactory cell adhesion and implant-related infections. To prevent such infections, a novel phase-transited lysozyme (PTL) was utilized as an initial functional layer to simply and effectively prime DMLS-Ti surfaces for subsequent coating with antibacterial multilayers. The purpose of the present study was to establish a surface with dual biological functionality. The minocycline-loaded polyelectrolyte multilayers of hyaluronic acid (HA) and chitosan (CS) formed via a layer-by-layer (LbL) self-assembly technique on PTL-functionalized DMLS-Ti were designed to inhibit pathogenic microbial infections while allowing the DMLS-Ti itself and the modified coatings to retain acceptable biocompatibility. The experimental results indicate that the DMLS-Ti and the hydrogel treated surfaces can inhibit early bacterial adhesion while completely preserving osteoblast functions. This design is expected to gain considerable interest in the medical field and to have good potential for applications in multifunctional DMLS-Ti implants. PMID:27821857
Guan, Binbin; Wang, Haorong; Xu, Ruiqing; Zheng, Guoying; Yang, Jie; Liu, Zihao; Cao, Man; Wu, Mingyao; Song, Jinhua; Li, Neng; Li, Ting; Cai, Qing; Yang, Xiaoping; Li, Yanqiu; Zhang, Xu
2016-11-08
Direct metal laser sintering is a technology that allows the fabrication of titanium (Ti) implants with a functional gradation of porosity and surface roughness according to three-dimensional (3D) computer data. The surface roughness of direct metal laser sintered titanium (DMLS-Ti) implants may provide abundant binding sites for bacteria. Bacterial colonization and subsequent biofilm formation can cause unsatisfactory cell adhesion and implant-related infections. To prevent such infections, a novel phase-transited lysozyme (PTL) was utilized as an initial functional layer to simply and effectively prime DMLS-Ti surfaces for subsequent coating with antibacterial multilayers. The purpose of the present study was to establish a surface with dual biological functionality. The minocycline-loaded polyelectrolyte multilayers of hyaluronic acid (HA) and chitosan (CS) formed via a layer-by-layer (LbL) self-assembly technique on PTL-functionalized DMLS-Ti were designed to inhibit pathogenic microbial infections while allowing the DMLS-Ti itself and the modified coatings to retain acceptable biocompatibility. The experimental results indicate that the DMLS-Ti and the hydrogel treated surfaces can inhibit early bacterial adhesion while completely preserving osteoblast functions. This design is expected to gain considerable interest in the medical field and to have good potential for applications in multifunctional DMLS-Ti implants.
NASA Astrophysics Data System (ADS)
Guan, Binbin; Wang, Haorong; Xu, Ruiqing; Zheng, Guoying; Yang, Jie; Liu, Zihao; Cao, Man; Wu, Mingyao; Song, Jinhua; Li, Neng; Li, Ting; Cai, Qing; Yang, Xiaoping; Li, Yanqiu; Zhang, Xu
2016-11-01
Direct metal laser sintering is a technology that allows the fabrication of titanium (Ti) implants with a functional gradation of porosity and surface roughness according to three-dimensional (3D) computer data. The surface roughness of direct metal laser sintered titanium (DMLS-Ti) implants may provide abundant binding sites for bacteria. Bacterial colonization and subsequent biofilm formation can cause unsatisfactory cell adhesion and implant-related infections. To prevent such infections, a novel phase-transited lysozyme (PTL) was utilized as an initial functional layer to simply and effectively prime DMLS-Ti surfaces for subsequent coating with antibacterial multilayers. The purpose of the present study was to establish a surface with dual biological functionality. The minocycline-loaded polyelectrolyte multilayers of hyaluronic acid (HA) and chitosan (CS) formed via a layer-by-layer (LbL) self-assembly technique on PTL-functionalized DMLS-Ti were designed to inhibit pathogenic microbial infections while allowing the DMLS-Ti itself and the modified coatings to retain acceptable biocompatibility. The experimental results indicate that the DMLS-Ti and the hydrogel treated surfaces can inhibit early bacterial adhesion while completely preserving osteoblast functions. This design is expected to gain considerable interest in the medical field and to have good potential for applications in multifunctional DMLS-Ti implants.
Silverton, Natalie A; Patel, Ravi; Zimmerman, Josh; Ma, Jianing; Stoddard, Greg; Selzman, Craig; Morrissey, Candice K
2018-02-15
To determine whether intraoperative measures of right ventricular (RV) function using transesophageal echocardiography are associated with subsequent RV failure after left ventricular assist device (LVAD) implantation. Retrospective, nonrandomized, observational study. Single tertiary-level, university-affiliated hospital. The study comprised 100 patients with systolic heart failure undergoing elective LVAD implantation. Transesophageal echocardiographic images before and after cardiopulmonary bypass were analyzed to quantify RV function using tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (S'), fractional area change (FAC), RV global longitudinal strain, and RV free wall strain. A chart review was performed to determine which patients subsequently developed RV failure (right ventricular assist device placement or prolonged inotrope requirement ≥14 days). Nineteen patients (19%) subsequently developed RV failure. Postbypass FAC was the only measure of RV function that distinguished between the RV failure and non-RV failure groups (21.2% v 26.5%; p = 0.04). The sensitivity, specificity, and area under the curve of an abnormal RV FAC (<35%) for RV failure after LVAD implantation were 84%, 20%, and 0.52, respectively. No other intraoperative measure of RV function was associated with subsequent RV failure. RV failure increased ventilator time, intensive care unit and hospital length of stay, and mortality. Intraoperative measures of RV function such as tricuspid annular plane systolic excursion, tricuspid annular systolic velocity, and RV strain were not associated with RV failure after LVAD implantation. Decreased postbypass FAC was significantly associated with RV failure but showed poor discrimination. Copyright © 2018 Elsevier Inc. All rights reserved.
Aronoff, Justin M.; Padilla, Monica; Fu, Qian-Jie; Landsberger, David M.
2015-01-01
Contralateral masking is the phenomenon where a masker presented to one ear affects the ability to detect a signal in the opposite ear. For normal hearing listeners, contralateral masking results in masking patterns that are both sharper and dramatically smaller in magnitude than ipsilateral masking. The goal of this study was to investigate whether medial olivocochlear (MOC) efferents are needed for the sharpness and relatively small magnitude of the contralateral masking function. To do this, bilateral cochlear implant patients were tested because, by directly stimulating the auditory nerve, cochlear implants circumvent the effects of the MOC efferents. The results indicated that, as with normal hearing listeners, the contralateral masking function was sharper than the ipsilateral masking function. However, although there was a reduction in the magnitude of the contralateral masking function compared to the ipsilateral masking function, it was relatively modest. This is in sharp contrast to the results of normal hearing listeners where the magnitude of the contralateral masking function is greatly reduced. These results suggest that MOC function may not play a large role in the sharpness of the contralateral masking function but may play a considerable role in the magnitude of the contralateral masking function. PMID:25798581
Arabnejad Khanoki, Sajad; Pasini, Damiano
2012-03-01
Revision surgeries of total hip arthroplasty are often caused by a deficient structural compatibility of the implant. Two main culprits, among others, are bone-implant interface instability and bone resorption. To address these issues, in this paper we propose a novel type of implant, which, in contrast to current hip replacement implants made of either a fully solid or a foam material, consists of a lattice microstructure with nonhomogeneous distribution of material properties. A methodology based on multiscale mechanics and design optimization is introduced to synthesize a graded cellular implant that can minimize concurrently bone resorption and implant interface failure. The procedure is applied to the design of a 2D left implanted femur with optimized gradients of relative density. To assess the manufacturability of the graded cellular microstructure, a proof-of-concept is fabricated by using rapid prototyping. The results from the analysis are used to compare the optimized cellular implant with a fully dense titanium implant and a homogeneous foam implant with a relative density of 50%. The bone resorption and the maximum value of interface stress of the cellular implant are found to be over 70% and 50% less than the titanium implant while being 53% and 65% less than the foam implant.
Clinical outcomes of implant therapy in ectodermal dysplasia patients: a systematic review.
Wang, Y; He, J; Decker, A M; Hu, J C; Zou, D
2016-08-01
The purpose of this review was to determine the outcome of oral function reconstruction in ectodermal dysplasia (ED) patients who have received dental implant therapy. A search was made of the PubMed and Web of Science databases; key words used were "(ectodermal dysplasia) AND (implant OR implants)", with supplementary retrieval key words "dental implant", "zygomatic implant", "anodontia", and "edentulous". Patient age, use of bone graft, implant site, type of implant, and survival rate of the implants were included in the subsequent data analysis. Forty-five articles published between 1988 and October 2015 were included in this analysis. The cases of a total of 96 patients were retrieved (22 children and 74 adults); these patients received a total of 701 implants. Fourteen implants were removed during a median follow-up time of 24 months. The 24-month implant survival rate was 97.9% in adult subjects and 98.6% in children. Sixty-eight percent of adult patients underwent bone augmentation prior to implant placement. Based on this review, dental implants are commonly used in the oral reconstruction of ED patients. However, long-term data on bone augmentation and implant success are needed, as well as additional clinical evidence on bone resorption, the esthetic outcomes of implant therapy, and physiological considerations in ED patients. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Davis, Timothy J.; Gifford, René H.
2018-01-01
Purpose: The primary purpose of this study was to derive spatial release from masking (SRM) performance-azimuth functions for bilateral cochlear implant (CI) users to provide a thorough description of SRM as a function of target/distracter spatial configuration. The secondary purpose of this study was to investigate the effect of the microphone…
Executive Functioning Skills in Preschool-Age Children with Cochlear Implants
ERIC Educational Resources Information Center
Beer, Jessica; Kronenberger, William G.; Castellanos, Irina; Colson, Bethany G.; Henning, Shirley C.; Pisoni, David B.
2014-01-01
Purpose: The purpose of this study was to determine whether deficits in executive functioning (EF) in children with cochlear implants (CIs) emerge as early as the preschool years. Method: Two groups of children ages 3 to 6 years participated in this cross-sectional study: 24 preschoolers who had CIs prior to 36 months of age and 21 preschoolers…
Soft Tissue Surgical Procedures for Optimizing Anterior Implant Esthetics
Ioannou, Andreas L.; Kotsakis, Georgios A.; McHale, Michelle G.; Lareau, Donald E.; Hinrichs, James E.; Romanos, Georgios E.
2015-01-01
Implant dentistry has been established as a predictable treatment with excellent clinical success to replace missing or nonrestorable teeth. A successful esthetic implant reconstruction is predicated on two fundamental components: the reproduction of the natural tooth characteristics on the implant crown and the establishment of soft tissue housing that will simulate a healthy periodontium. In order for an implant to optimally rehabilitate esthetics, the peri-implant soft tissues must be preserved and/or augmented by means of periodontal surgical procedures. Clinicians who practice implant dentistry should strive to achieve an esthetically successful outcome beyond just osseointegration. Knowledge of a variety of available techniques and proper treatment planning enables the clinician to meet the ever-increasing esthetic demands as requested by patients. The purpose of this paper is to enhance the implant surgeon's rationale and techniques beyond that of simply placing a functional restoration in an edentulous site to a level whereby an implant-supported restoration is placed in reconstructed soft tissue, so the site is indiscernible from a natural tooth. PMID:26124837
ERIC Educational Resources Information Center
Leigh, Irene W.; Maxwell-McCaw, Deborah; Bat-Chava, Yael; Christiansen, John B.
2009-01-01
The number of children who have received cochlear implants (CIs) has increased dramatically in the past two decades. In view of potential concerns about their psychosocial adjustment, our aim was to assess the effect of implants on the adolescents' psychosocial functioning among a group of 57 deaf adolescents with and without CIs, using published…
[Use of porous titanium nickelide dental implants].
Radkevich, A A; Galonskiĭ, V G; Gantimurov, A A
2013-01-01
The paper presents the results of 20 years clinical experience in dental prosthetics with the use of porous titanium nickelide dental implants. Implants were placed in 565 patients aged 15-17 years. Long-term results analysis showed restorations to function properly after mean follow-up period of 8 years in 435 patients (78.2%) proving this material to be clinically successful.
NASA Astrophysics Data System (ADS)
Patel, J. R.
2002-06-01
Stacking faults in boron-implanted silicon give rise to streaks or rods of scattered x-ray intensity normal to the stacking fault plane. We have used the diffuse scattering rods to follow the growth of faults as a function of time when boron-implanted silicon is annealed in the range 925 - 1025 C.
Antimicrobial surfaces for craniofacial implants: state of the art.
Actis, Lisa; Gaviria, Laura; Guda, Teja; Ong, Joo L
2013-04-01
In an attempt to regain function and aesthetics in the craniofacial region, different biomaterials, including titanium, hydroxyapatite, biodegradable polymers and composites, have been widely used as a result of the loss of craniofacial bone. Although these materials presented favorable success rates, osseointegration and antibacterial properties are often hard to achieve. Although bone-implant interactions are highly dependent on the implant's surface characteristics, infections following traumatic craniofacial injuries are common. As such, poor osseointegration and infections are two of the many causes of implant failure. Further, as increasingly complex dental repairs are attempted, the likelihood of infection in these implants has also been on the rise. For these reasons, the treatment of craniofacial bone defects and dental repairs for long-term success remains a challenge. Various approaches to reduce the rate of infection and improve osseointegration have been investigated. Furthermore, recent and planned tissue engineering developments are aimed at improving the implants' physical and biological properties by improving their surfaces in order to develop craniofacial bone substitutes that will restore, maintain and improve tissue function. In this review, the commonly used biomaterials for craniofacial bone restoration and dental repair, as well as surface modification techniques, antibacterial surfaces and coatings are discussed.
Verbal Working Memory in Children With Cochlear Implants
Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.
2017-01-01
Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747
Berberi, Antoine N.; Sabbagh, Joseph M.; Aboushelib, Moustafa N.; Noujeim, Ziad F.; Salameh, Ziad A.
2014-01-01
Purpose: The aim of present investigation was to evaluate marginal bone level after 5-year follow-up of implants placed in healed ridges and fresh extraction sockets in maxilla with immediate loading protocol. Materials and Methods: Thirty-six patients in need of a single-tooth replacement in the anterior maxilla received 42 Astra Tech implants (Astra Tech Implant system™, Dentsply Implants, Mölndal, Sweden). Implants were placed either in healed ridges (group I) or immediately into fresh extraction sockets (group II). Implants were restored and placed into functional loading immediately by using a prefabricated abutment. Marginal bone level relative to the implant reference point was recorded at implant placement, crown cementation, 12, 36, and 60 months following loading using intra-oral radiographs. Measurements were made on the mesial and distal sides of each implant. Results: Overall, two implants were lost from the group II, before final crown cementation: they were excluded from the study. The mean change in marginal bone loss (MBL) after implant placement was 0.26 ± 0.161 mm for 1 year, and 0.26 ± 0.171 mm for 3 years, and 0.21 ± 0.185 mm for 5 years in extraction sockets and was 0.26 ± 0.176 mm for 1 year and 0.21 ± 0.175 mm for 3 years, and 0.19 ± 0.172 mm for 5 years in healed ridges group. Significant reduction of marginal bone was more pronounced in implants inserted in healed ridges (P < 0.041) compared to fresh surgical extraction sockets (P < 0.540). Significant MBL was observed on the mesial side of the implant after cementation of the provisional (P < 0.007) and after 12 months (P < 0.034) compared to the distal side which remained stable for 3 and 5 years observation period. Conclusions: Within the limitations of this study, responses of local bone to immediately loaded implants placed either in extraction sockets or healed ridges were similar. Functional loading technique by using prefabricated abutment placed during the surgery time seems to maintain marginal bone around implant in both healed and fresh extraction sites. PMID:24550840
Complications in implant dentistry
Hanif, Ayesha; Qureshi, Saima; Sheikh, Zeeshan; Rashid, Haroon
2017-01-01
After tooth loss, an individual may seek tooth replacement so that his/her function and esthetics could be restored. Clinical prosthodontics, during the past decade, has significantly improved and developed according to the advancements in the science and patient's demands and needs. Conventional options in prosthodontics for substituting a missing single tooth include the removable partial denture, partial and full coverage bridgework, and resin-bonded bridgework. Dental implants have gained increasing popularity over the years as they are capable of restoring the function to near normal in both partial and completely edentulous arches. With substantial evidence available, fixed implant-supported prosthesis are fully acknowledged as a reliable treatment option for the replacement of single or multiple missing teeth nowadays. While dental implants are increasingly becoming the choice of replacement for missing teeth, the impediments associated with them are progressively emerging too. PMID:28435381
Huang, Jiahua; Zhou, Hai; Zhang, Binbin; Ding, Biao
2015-09-01
This article develops a new failure database software for orthopaedics implants based on WEB. The software is based on B/S mode, ASP dynamic web technology is used as its main development language to achieve data interactivity, Microsoft Access is used to create a database, these mature technologies make the software extend function or upgrade easily. In this article, the design and development idea of the software, the software working process and functions as well as relative technical features are presented. With this software, we can store many different types of the fault events of orthopaedics implants, the failure data can be statistically analyzed, and in the macroscopic view, it can be used to evaluate the reliability of orthopaedics implants and operations, it also can ultimately guide the doctors to improve the clinical treatment level.
The “curved lead pathway” method to enable a single lead to reach any two intracranial targets
NASA Astrophysics Data System (ADS)
Ding, Chen-Yu; Yu, Liang-Hong; Lin, Yuan-Xiang; Chen, Fan; Lin, Zhang-Ya; Kang, De-Zhi
2017-01-01
Deep brain stimulation is an effective way to treat movement disorders, and a powerful research tool for exploring brain functions. This report proposes a “curved lead pathway” method for lead implantation, such that a single lead can reach in sequence to any two intracranial targets. A new type of stereotaxic system for implanting a curved lead to the brain of human/primates was designed, the auxiliary device needed for this method to be used in rat/mouse was fabricated and verified in rat, and the Excel algorithm used for automatically calculating the necessary parameters was implemented. This “curved lead pathway” method of lead implantation may complement the current method, make lead implantation for multiple targets more convenient, and expand the experimental techniques of brain function research.
Eto, Shuichi; Miyamoto, Hiroshi; Shobuike, Takeo; Noda, Iwao; Akiyama, Takayuki; Tsukamoto, Masatsugu; Ueno, Masaya; Someya, Shinsuke; Kawano, Shunsuke; Sonohata, Motoki; Mawatari, Masaaki
2015-09-01
Antibacterial silver with hydroxyapatite (Ag-HA) is a promising coating material for imparting antibacterial properties to implants. We previously reported that 3% (w/w) silver with HA (3% Ag-HA) has both antibacterial activity and osteoconductivity. In this study, we investigated the effects of Ag-HA on the in vitro osteoblast function and the in vivo anchorage strength and osteoconductivity of implants. Production of the osteoblast marker alkaline phosphatase, but not cytotoxicity, was observed in cells of the osteoblast cell line MC3T3-E1 cultured on the 3% Ag-HA-coated surface. These results were similar to those observed with silver-free HA coating. In contrast, a significant high level of cytotoxicity was observed when the cells were cultured on a 50% Ag-HA-coated surface. The anchorage strength of implants inserted into the femur of Sprague-Dawley (SD) rats was enhanced by coating the implants with 3% Ag-HA. On the 3% Ag-HA-coated surface, both metaphyseal and diaphyseal areas were largely covered with new bone and had adequate osteoconductivity. These results suggest that 3% Ag-HA, like conventional HA, promotes osteogenesis by supporting osteoblast viability and function and thereby contributes to sufficient anchorage strength of implants. Application of 3% Ag-HA, which combines the osteoconductivity of HA and the antibacterial activity of silver, to prosthetic joints will help prevent postoperative infections. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Zygomatic implant-retained fixed complete denture for an elderly patient.
Baig, Mirza Rustum; Rajan, Gunaseelan; Yunus, Norsiah
2012-06-01
Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics. © 2011 The Gerodontology Society and John Wiley & Sons A/S.
Developmental Effects of Family Environment on Outcomes in Pediatric Cochlear Implant Recipients
Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.
2012-01-01
Objective To examine and compare the family environment of preschool- and school-age children with cochlear implants and assess its influence on children’s executive function and spoken language skills. Study Design Retrospective between-subjects design. Setting Outpatient research laboratory. Patients Prelingually deaf children with cochlear implants and no additional disabilities, and their families. Intervention(s) Cochlear implantation and speech-language therapy. Main Outcome Measures Parents completed the Family Environment Scale and the Behavior Rating Inventory of Executive Function (or the preschool version). Children were tested using the Peabody Picture Vocabulary Test-4 and either the Preschool Language Scales-4 or the Clinical Evaluation of Language Fundamentals–4. Results The family environments of children with cochlear implants differed from normative data obtained from hearing children, but average scores were within one standard deviation of norms on all subscales. Families of school-age children reported higher levels of control than those of preschool-age children. Preschool-age children had fewer problems with emotional control when families reported higher levels of support and lower levels of conflict. School-age children had fewer problems with inhibition but more problems with shifting of attention when families reported lower levels of conflict. School-age children’s receptive vocabularies were enhanced by families with lower levels of control and higher levels of organization. Conclusions Family environment and its relation to language skills and executive function development differed across the age groups in this sample of children with cochlear implants. Because family dynamics is one developmental/environmental factor that can be altered with therapy and education, the present results have important clinical implications for family-based interventions for deaf children with cochlear implants. PMID:23151776
Sorcin is involved during embryo implantation via activating VEGF/PI3K/Akt pathway in mice.
Gupta, Kanchan; Sirohi, Vijay Kumar; Kumari, Suparna; Shukla, Vinay; Manohar, Murli; Popli, Pooja; Dwivedi, Anila
2018-02-01
Our earlier studies have demonstrated the cyclic variation and also the altered expression of sorcin in endometrium during early-to-mid-secretory phase transition in women with unexplained infertility. The current study was undertaken to establish the functional role of sorcin in endometrial receptivity in mice. Results indicated that sorcin was highly expressed during the window of implantation in mice and functional blockage of sorcin caused significant reduction in number of implanted blastocyst. The receptivity markers (i.e.Integrin β3, HBEGF, IGFBP1, WNT4 and Cyclin E)) were found to be downregulated in sorcin knocked down uterine horn on day 5 as compared to untreated horn. The reduced attachment and expansion of BeWo spheroids on RL95-2 endometrial cells with sorcin knock down, in in vitro model of endometrium-trophoblast interaction further supported these findings. Uterine sorcin expression pattern during estrous cycle and in delayed implantation mice model suggested the upregulation of sorcin by estrogen. The functional blockade of sorcin induced the intracellular Ca +2 levels in endometrial epithelial cells (EECs), which indicated that altered Ca +2 homeostasis might be responsible for implantation failure. Sorcin silencing led to significant reduction in the expression of angiogenic factor VEGF and its downstream effector molecules i.e. PI3K, Akt and NOS. The migratory and invasive properties of HUVECs were abrogated by anti-VEGF or by adding culture media from sorcin blocked EECs, which indicated that sorcin might mediate angiogenesis during implantation. Taken together, sorcin is involved in the regulation of Ca +2 -mediated angiogenesis via VEGF/PI3K/Akt pathway in endometrial cells and plays a crucial role in preparing the endometrium for implantation. © 2018 Society for Endocrinology.
Current aspects in reconstructive surgery for nasal cavity and paranasal sinus cancer
NASA Astrophysics Data System (ADS)
Shtin, V. I.; Novikov, V. A.; Gjunter, V. E.; Choinzonov, E. L.; Ryabova, A. I.; Sirkashev, V. A.; Surkova, P. V.; Vasilev, R. V.; Menkova, E. N.
2017-09-01
Tumors of the nasal cavity and paranasal sinuses present a challenge to treat them. A combination of surgery and radiation therapy can improve treatment outcomes in 49-56% [1, 2] of the patients with locally advanced nasal cavity and paranasal sinus cancer. The midface reconstruction poses a formidable challenge to the reconstructive surgeon due to the region's complex skeletal and soft-tissue anatomy. The rehabilitation program including the reconstruction of the resected orbital walls using the porous and mesh implants from titanium nickelid (TiNi) was developed at the Cancer Research institute jointly with the Research Institute of Medical Materials. The technique was proven effective, allowing the natural position of the eye and visual function to be preserved in 90% [1-3] of the patients. A long period of reparative processes and risk of developing inflammation in the implant area, as well as the need to decrease length of surgery, contributed to the development of a novel approach to repairing the midface bone structures using the implant based on the microporous wire and TiNi mesh. Eighteen patients with nasal cavity and paranasal sinus cancer were treated using the combined thin implants. The novel technique allowed the time of the implant installation to be reduced to 5-10 min. The structure of the implant contributed to prevention of inflammatory processes in 97% [1, 2] of cases. Thus, the natural position of the eyeball and visual function were preserved in 100% [1, 3, 4] of patients. The use of the TiNi implants in reconstructive surgery for patients with nasal cavity and paranasal sinus cancer led to reduced time of surgery and rehabilitation, increased level of social adaptation of patients and improved cosmetic and functional results.
Gillard, Pieter; Hilbrands, Robert; Van de Velde, Ursule; Ling, Zhidong; Lee, Da Hae; Weets, Ilse; Gorus, Frans; De Block, Christophe; Kaufman, Leonard; Mathieu, Chantal; Pipeleers, Daniel; Keymeulen, Bart
2013-11-01
Previous work has shown a correlation between β-cell number in cultured islet cell grafts and their ability to induce C-peptide secretion after intraportal implantation in C-peptide-negative type1 diabetic patients. In this cross-sectional study, we examined the minimal functional β-cell mass (FBM) in the implant that induces metabolic improvement. Glucose clamps assessed FBM in 42 recipients with established implants. C-peptide release during each phase was expressed as percentage of healthy control values. Its relative magnitude during a second hyperglycemic phase was most discriminative and therefore selected as a parameter to be correlated with metabolic effects. Recipients with functioning β-cell implants exhibited average FBM corresponding to 18% of that in normal control subjects (interquartile range 10-33%). Its relative magnitude negatively correlated with HbA1c levels (r = -0.47), daily insulin dose (r = -0.75), and coefficient of variation of fasting glycemia (CVfg) (r = -0.78, retained in multivariate analysis). A correlation between FBM and CVfg <25% appeared from the receiver operating characteristic curve (0.97 [95% CI 0.93-1.00]). All patients with FBM >37% exhibited CVfg <25% and a >50% reduction of their pretransplant CVfg; this occurred in none with FBM <5%. Implants with FBM >18% reduced CVfg from a median pretransplant value of 46 to <25%. Glucose clamping assesses the degree of restoration in FBM achieved by islet cell implants. Values >37% of normal control subjects appear needed to reduce glycemic variability in type 1 diabetic recipients. Further studies should examine whether the test can help guide decisions on additional islet cell transplants and on adjusting or stopping immunotherapy.
Mehl, N S; Srisuwatanasagul, S; Swangchan-Uthai, T; Sirivaidyapong, S; Khalid, M
2017-01-01
Effect of a GnRH-agonist (deslorelin) was studied on reproductive function and ovarian luteinizing hormone receptor (LHR) and follicle stimulating hormone receptor (FSHR) expression in prepubertal female cats that were either implanted with 4.7-mg deslorelin (implanted: n = 6) or not (controls: n = 18) or ovariohysterectomized at prepubertal age (prepubertal OVH: n = 6). Body weights, fecal estradiol, and sexual behavior of implanted and control cats were monitored for 48 weeks followed by collection of ovaries and uteri. Ovaries and uteri were collected from control cats at follicular, luteal, and inactive stage (n = 6/group) and from prepubertal OVH cats at prepubertal age. Ovaries and uteri were analyzed for anatomical/histological characteristics. Ovaries were also analyzed for LHR and FSHR expression. Statistical analysis showed higher (P ≤ 0.05) body weight in control than implanted cats only during 22nd to 26th weeks of the study. Estrus was observed in control cats only. Deslorelin reduced (P ≤ 0.05) ovarian weight and number of antral follicles but did not affect endometrial thickness and gland diameter. However, myometrial thickness of implanted cats was significantly lower than control cats at follicular and luteal stage. Ovarian LHR mRNA expression was lower (P ≤ 0.05) in implanted cats than control cats at follicular stage. FSHR mRNA and LHR protein expression did not differ among the three groups. FSHR protein expression was lower (P ≤ 0.05) in prepubertal OVH cats and was not affected by deslorelin. In conclusion, deslorelin suppresses reproductive function in prepubertal female cats for at least 48 weeks possibly through a change in the ovarian mRNA expression of LHR. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shipsey, Ian
In his talk, Shipsey will discuss the cochlear implant, the first device to successfully allow the profoundly deaf to regain some sense of hearing. A cochlear implant is a small electronic apparatus. Unlike a normal hearing aid, which amplifies sound, a cochlear implant is surgically implanted behind the ear where it converts sound waves into electrical impulses. These implants have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. Shipsey will discuss the physiology of natural hearing from the perspective of a physicist. He willmore » also touch on the function of cochlear implants in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. Finally, Shipsey will address the social implications of cochlear implantation and the future outlook for auditory prostheses.« less
Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature.
Hasan, Istabrak; Bourauel, Christoph; Mundt, Torsten; Stark, Helmut; Heinemann, Friedhelm
2014-02-01
In recent years, the application of small-diameter and mini dental implants to support removable and fixed prosthesis has dramatically increased. However, the success of these implants under functional biting forces and the reaction of the bone around them need to be analyzed. This review was aimed to present studies that deal with the fatigue life of small-diameter and mini dental implants under normal biting force, and their survival rate. The numerical and experimental studies concluded that an increase in the risk of bone damage or implant failure may be assumed in critical clinical situations and implants with <3 mm diameter have a risk of fracture in clinical practice. The survival rate of the small-diameter and mini dental implants over 5 years was 98.3-99.4%.
Klueh, Ulrike; Antar, Omar; Qiao, Yi; Kreutzer, Donald L.
2014-01-01
The concept of increased blood vessel (BV) density proximal to glucose sensors implanted in the interstitial tissue increases the accuracy and lifespan of sensors is accepted, despite limited existing experimental data. Interestingly, there is no previous data or even conjecture in the literature on the role of lymphatic vessels (LV) alone, or in combination with BV, in enhancing continuous glucose monitoring (CGM) in vivo. To investigate the impact of inducing vascular networks (BV and LV) at sites of glucose sensor implantation, we utilized adenovirus based local gene therapy of vascular endothelial cell growth factor-A (VEGF-A) to induce vessels at sensor implantation sites. The results of these studies demonstrated that 1) VEGF-A based local gene therapy increases vascular networks (blood vessels and lymphatic vessels) at sites of glucose sensor implantation; and 2) this local increase of vascular networks enhances glucose sensor function in vivo from 7 days to greater than 28 days post sensor implantation. This data provides “proof of concept” for the effective usage of local angiogenic factor (AF) gene therapy in mammalian models in an effort to extend CGM in vivo. It also supports the practice of a variety of viral and non-viral vectors as well as gene products (e.g. anti-inflammatory and anti-fibrosis genes) to engineer “implant friendly tissues” for the usage with implantable glucose sensors as well as other implantable devices. PMID:24243850
Soft tissue wound healing around teeth and dental implants.
Sculean, Anton; Gruber, Reinhard; Bosshardt, Dieter D
2014-04-01
To provide an overview on the biology and soft tissue wound healing around teeth and dental implants. This narrative review focuses on cell biology and histology of soft tissue wounds around natural teeth and dental implants. The available data indicate that: (a) Oral wounds follow a similar pattern. (b) The tissue specificities of the gingival, alveolar and palatal mucosa appear to be innately and not necessarily functionally determined. (c) The granulation tissue originating from the periodontal ligament or from connective tissue originally covered by keratinized epithelium has the potential to induce keratinization. However, it also appears that deep palatal connective tissue may not have the same potential to induce keratinization as the palatal connective tissue originating from an immediately subepithelial area. (d) Epithelial healing following non-surgical and surgical periodontal therapy appears to be completed after a period of 7–14 days. Structural integrity of a maturing wound between a denuded root surface and a soft tissue flap is achieved at approximately 14-days post-surgery. (e) The formation of the biological width and maturation of the barrier function around transmucosal implants requires 6–8 weeks of healing. (f) The established peri-implant soft connective tissue resembles a scar tissue in composition, fibre orientation, and vasculature. (g) The peri-implant junctional epithelium may reach a greater final length under certain conditions such as implants placed into fresh extraction sockets versus conventional implant procedures in healed sites. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cebrian-Carretero, José L.; Sobrino, José A.; Yu, Tomás; Burgueño-García, Miguel
2014-01-01
The reconstruction of maxillomandibular defects secondary to oral cancer surgery, represent a great challenge for Maxillofacial surgeons. During the last decades the reconstructive surgery has experimented a big advance due to the development of the microsurgical techniques. At present, we are able to reconstruct complex defects using free flaps that provide both soft and bone tissue. Fibula, iliac crest and scapula free flaps have been the three classic options for the maxillomandibular reconstruction owing to the amount of bone that this flaps provide, allowing the posterior dental rehabilitation with implants. Today, our objective it is not only the aesthetic reconstruction, but also the functional reconstruction of the patients enhancing their life quality. Guided implant surgery in free flap reconstructed patients has become an essential tool, helping to define the exact position of the dental implant in the flap. In this way it is possible to look for the areas with better bone conditions, avoiding the osteosynthesis material used to fixate the flap with the native bone and deciding the best biomechanical option, in terms of number and situation of the implants, for the future dental prostheses. In summary, using the guided implant surgery, it is possible to design an exact and predictable dental implant rehabilitation in patients with oral cancer who are reconstructed with free microvascular flap, resulting in an optimal aesthetic and functional result. Key words:Oral cancer, mandibulectomy, maxillectomy, microvascular reconstruction, fibula flap, dental implant, guided surgery. PMID:25129241