Sample records for functional test procedure

  1. Light duty utility arm phase 2 qualification test procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, G.A.

    1997-01-16

    This Acceptance Test Procedure (ATP) will test and verify that the Exhauster meets the specified functional requirements, safety requirements, operating requirements, and provide a record of the functional test results. The system/functions that will be tested are listed in the scope section of the Acceptance Test Procedure.

  2. 78 FR 21074 - Airworthiness Directives; Bombardier, Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-09

    ... the maintenance requirements manual (MRM) by incorporating procedures for repetitive functional tests... the new tests, removing of the existing procedures for the repetitive functional tests from the MRM...

  3. The interval testing procedure: A general framework for inference in functional data analysis.

    PubMed

    Pini, Alessia; Vantini, Simone

    2016-09-01

    We introduce in this work the Interval Testing Procedure (ITP), a novel inferential technique for functional data. The procedure can be used to test different functional hypotheses, e.g., distributional equality between two or more functional populations, equality of mean function of a functional population to a reference. ITP involves three steps: (i) the representation of data on a (possibly high-dimensional) functional basis; (ii) the test of each possible set of consecutive basis coefficients; (iii) the computation of the adjusted p-values associated to each basis component, by means of a new strategy here proposed. We define a new type of error control, the interval-wise control of the family wise error rate, particularly suited for functional data. We show that ITP is provided with such a control. A simulation study comparing ITP with other testing procedures is reported. ITP is then applied to the analysis of hemodynamical features involved with cerebral aneurysm pathology. ITP is implemented in the fdatest R package. © 2016, The International Biometric Society.

  4. Environmental Test Screening Procedure

    NASA Technical Reports Server (NTRS)

    Zeidler, Janet

    2000-01-01

    This procedure describes the methods to be used for environmental stress screening (ESS) of the Lightning Mapper Sensor (LMS) lens assembly. Unless otherwise specified, the procedures shall be completed in the order listed, prior to performance of the Acceptance Test Procedure (ATP). The first unit, S/N 001, will be subjected to the Qualification Vibration Levels, while the remainder will be tested at the Operational Level. Prior to ESS, all units will undergo Pre-ESS Functional Testing that includes measuring the on-axis and plus or minus 0.95 full field Modulation Transfer Function and Back Focal Length. Next, all units will undergo ESS testing, and then Acceptance testing per PR 460.

  5. Comparison of effects of dry versus wet swallowing on Eustachian tube function via a nine-step inflation/deflation test.

    PubMed

    Adali, M Kemal; Uzun, Cem

    2005-09-01

    The aim of the present study is to evaluate the effect of swallowing type (dry versus wet) on the outcome of a nine-step inflation/deflation tympanometric Eustachian tube function (ETF) test in healthy adults. Fourteen normal healthy volunteers, between 19 and 28 years of age, were included in the study. The nine-step test was performed in two different test procedures: (1) test with dry swallows (dry test procedure) and (2) test with liquid swallows (wet test procedure). If the equilibration of middle-ear (ME) pressure was successful in all the steps of the nine-step test, ETF was considered 'Good'. Otherwise, the test was considered 'Poor', and the test was repeated at a second session. In the dry test procedure, ETF was 'Good' in 21 ears at the first session and in 24 ears after the second session (p > 0.05). However, in the wet test procedure, ETF was 'Good' in 13 ears at the first session and in 21 ears after the second session (p < 0.05). At the first session, ETF was 'Good' in 21 and 13 ears in the dry and wet test procedures, respectively. The difference was statistically significant (p < 0.05). However, after the second session, the overall number of ears with 'Good' tubal function was almost the same in both test procedures (24 ears at dry test procedures versus 21 ears at wet test procedures;p > 0.05). Dry swallowing seems to be more effective for the equilibration of ME pressure. Thus, a single-session dependent evaluation of ETF may be efficient for the dry test procedure of the nine-step test. Swallowing with water may be easier for subjects, but a repetition of the test at a second session may be necessary when the test result is 'Poor'.

  6. Enraf Series 854 advanced technology gauge (ATG) acceptance test procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huber, J.H.

    1996-09-11

    This Acceptance Test Procedure was written to test the Enraf Series 854 Advanced Technology Gauge (ATG) prior to installation in the Tank Farms. The procedure sets various parameters and verifies that the gauge is functional.

  7. Classical Testing in Functional Linear Models.

    PubMed

    Kong, Dehan; Staicu, Ana-Maria; Maity, Arnab

    2016-01-01

    We extend four tests common in classical regression - Wald, score, likelihood ratio and F tests - to functional linear regression, for testing the null hypothesis, that there is no association between a scalar response and a functional covariate. Using functional principal component analysis, we re-express the functional linear model as a standard linear model, where the effect of the functional covariate can be approximated by a finite linear combination of the functional principal component scores. In this setting, we consider application of the four traditional tests. The proposed testing procedures are investigated theoretically for densely observed functional covariates when the number of principal components diverges. Using the theoretical distribution of the tests under the alternative hypothesis, we develop a procedure for sample size calculation in the context of functional linear regression. The four tests are further compared numerically for both densely and sparsely observed noisy functional data in simulation experiments and using two real data applications.

  8. Classical Testing in Functional Linear Models

    PubMed Central

    Kong, Dehan; Staicu, Ana-Maria; Maity, Arnab

    2016-01-01

    We extend four tests common in classical regression - Wald, score, likelihood ratio and F tests - to functional linear regression, for testing the null hypothesis, that there is no association between a scalar response and a functional covariate. Using functional principal component analysis, we re-express the functional linear model as a standard linear model, where the effect of the functional covariate can be approximated by a finite linear combination of the functional principal component scores. In this setting, we consider application of the four traditional tests. The proposed testing procedures are investigated theoretically for densely observed functional covariates when the number of principal components diverges. Using the theoretical distribution of the tests under the alternative hypothesis, we develop a procedure for sample size calculation in the context of functional linear regression. The four tests are further compared numerically for both densely and sparsely observed noisy functional data in simulation experiments and using two real data applications. PMID:28955155

  9. French consensus procedure for assessing cognitive function in Parkinson's disease.

    PubMed

    Dujardin, K; Auzou, N; Lhommée, E; Czernecki, V; Dubois, B; Fradet, A; Maltete, D; Meyer, M; Pineau, F; Schmitt, E; Sellal, F; Tison, F; Vidal, T; Azulay, J-P; Welter, M-L; Corvol, J-C; Durif, F; Rascol, O

    2016-11-01

    One of the objectives of the French expert centers for Parkinson's disease (NS-Park) network was to determine a consensus procedure for assessing cognitive function in patients with Parkinson's. This article presents this procedure and briefly describes the selected tests. A group of 13 experts used the Delphi method for consensus building to define the overall structure and components of the assessment procedure. For inclusion in the battery, tests had to be validated in the French language, require little motor participation, have normative data and be recognized by the international community. Experimental tasks and tests requiring specific devices were excluded. Two possibilities were identified, depending on whether an abbreviated or comprehensive assessment of cognitive function was necessary. For an abbreviated assessment, the experts recommended the Montreal Cognitive Assessment (MoCA) as a screening test for cognitive impairment or dementia. For a comprehensive neuropsychological assessment, the experts recommended assessing global efficiency plus the five main cognitive domains (attention and working memory, executive function, episodic memory, visuospatial function and language) that may be impaired in Parkinson's disease, using two tests for each domain. A common procedure for assessing cognitive function is now available across the French network dedicated to Parkinson's disease, and is recommended for both research and clinical practice. It will also help to promote standardization of the neuropsychological assessment of Parkinson's disease. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. ENRAF Series 854 Advanced Technology Gauge (ATG) with SPU II card for Leak Detector Use Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SMITH, S.G.

    1999-10-21

    The following Acceptance Test Procedure was written to test the ENRAF series 854 ATG with SPU II card prior to installation in the Tank Farms. The procedure sets various parameters and verifies the gauge and alarms functionality.

  11. Test functions for three-dimensional control-volume mixed finite-element methods on irregular grids

    USGS Publications Warehouse

    Naff, R.L.; Russell, T.F.; Wilson, J.D.; ,; ,; ,; ,; ,

    2000-01-01

    Numerical methods based on unstructured grids, with irregular cells, usually require discrete shape functions to approximate the distribution of quantities across cells. For control-volume mixed finite-element methods, vector shape functions are used to approximate the distribution of velocities across cells and vector test functions are used to minimize the error associated with the numerical approximation scheme. For a logically cubic mesh, the lowest-order shape functions are chosen in a natural way to conserve intercell fluxes that vary linearly in logical space. Vector test functions, while somewhat restricted by the mapping into the logical reference cube, admit a wider class of possibilities. Ideally, an error minimization procedure to select the test function from an acceptable class of candidates would be the best procedure. Lacking such a procedure, we first investigate the effect of possible test functions on the pressure distribution over the control volume; specifically, we look for test functions that allow for the elimination of intermediate pressures on cell faces. From these results, we select three forms for the test function for use in a control-volume mixed method code and subject them to an error analysis for different forms of grid irregularity; errors are reported in terms of the discrete L2 norm of the velocity error. Of these three forms, one appears to produce optimal results for most forms of grid irregularity.

  12. POWER-ENHANCED MULTIPLE DECISION FUNCTIONS CONTROLLING FAMILY-WISE ERROR AND FALSE DISCOVERY RATES.

    PubMed

    Peña, Edsel A; Habiger, Joshua D; Wu, Wensong

    2011-02-01

    Improved procedures, in terms of smaller missed discovery rates (MDR), for performing multiple hypotheses testing with weak and strong control of the family-wise error rate (FWER) or the false discovery rate (FDR) are developed and studied. The improvement over existing procedures such as the Šidák procedure for FWER control and the Benjamini-Hochberg (BH) procedure for FDR control is achieved by exploiting possible differences in the powers of the individual tests. Results signal the need to take into account the powers of the individual tests and to have multiple hypotheses decision functions which are not limited to simply using the individual p -values, as is the case, for example, with the Šidák, Bonferroni, or BH procedures. They also enhance understanding of the role of the powers of individual tests, or more precisely the receiver operating characteristic (ROC) functions of decision processes, in the search for better multiple hypotheses testing procedures. A decision-theoretic framework is utilized, and through auxiliary randomizers the procedures could be used with discrete or mixed-type data or with rank-based nonparametric tests. This is in contrast to existing p -value based procedures whose theoretical validity is contingent on each of these p -value statistics being stochastically equal to or greater than a standard uniform variable under the null hypothesis. Proposed procedures are relevant in the analysis of high-dimensional "large M , small n " data sets arising in the natural, physical, medical, economic and social sciences, whose generation and creation is accelerated by advances in high-throughput technology, notably, but not limited to, microarray technology.

  13. ENRAF Series 854 Advanced Technology Gauge (ATG) with SPU ll Card for Leak Detector Use Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SMITH, S.G.

    1999-08-13

    This procedure checks the Enraf gauge received at Hanford is completely functional and has received no shipping damage. This procedure does not certify the gauge operation. The manufacturer certifies gauge operation. This procedure provides acceptance testing for Enraf Series 854 level gauges used to detect leaks in Hanford Waste Storage Tank annuli. The test will verify that the gauge functions according to the manufacturer's instructions and specifications and is properly setup prior to being delivered to the tank farm area. This ATP does not set up the gauge for any specific tank, but is generalized to permit testing the gaugemore » prior to installation package preparation.« less

  14. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices.

    PubMed

    Kraft, Marc

    2008-09-03

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority.

  15. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices

    PubMed Central

    Kraft, Marc

    2008-01-01

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority. PMID:20204095

  16. Pulmonary Screening in Subjects after the Fontan Procedure.

    PubMed

    Liptzin, Deborah R; Di Maria, Michael V; Younoszai, Adel; Narkewicz, Michael R; Kelly, Sarah L; Wolfe, Kelly R; Veress, Livia A

    2018-05-07

    To review the pulmonary findings of the first 51 patients who presented to our interdisciplinary single-ventricle clinic after undergoing the Fontan procedure. We performed an Institutional Review Board-approved retrospective review of 51 patients evaluated following the Fontan procedure. Evaluation included history, physical examination, pulmonary function testing, and 6-minute walk. Descriptive statistics were used to describe the population and testing data. Sixty-one percent of the patients had a pulmonary concern raised during the visit. Three patients had plastic bronchitis. Abnormal lung function testing was present in 46% of patients. Two-thirds (66%) of the patients had significant desaturation during the 6-minute walk test. Patients who underwent a fenestrated Fontan procedure and those who underwent unfenestrated Fontan were compared in terms of saturation and 6-minute walk test results. Sleep concerns were present in 45% of the patients. Pulmonary morbidities are common in patients after Fontan surgery and include plastic bronchitis, abnormal lung function, desaturations with walking, and sleep concerns. Abnormal lung function and obstructive sleep apnea may stress the Fontan circuit and may have implications for cognitive and emotional functioning. A pulmonologist involved in the care of patients after Fontan surgery can assist in screening for comorbidities and recommend interventions. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Evaluation of the CATSIB DIF Procedure in a Pretest Setting

    ERIC Educational Resources Information Center

    Nandakumar, Ratna; Roussos, Louis

    2004-01-01

    A new procedure, CATSIB, for assessing differential item functioning (DIF) on computerized adaptive tests (CATs) is proposed. CATSIB, a modified SIBTEST procedure, matches test takers on estimated ability and controls for impact-induced Type 1 error inflation by employing a CAT version of the IBTEST "regression correction." The…

  18. 42 CFR 493.1449 - Standard; Technical supervisor qualifications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... service in which the laboratory performs high complexity tests or procedures. The director of a laboratory... may perform anatomic and clinical laboratory procedures and tests in all specialties and... tests in the subspecialty of bacteriology, the individual functioning as the technical supervisor must...

  19. Application of modified profile analysis to function testing of the motion/no-motion issue in an aircraft ground-handling simulation. [statistical analysis procedure for man machine systems flight simulation

    NASA Technical Reports Server (NTRS)

    Parrish, R. V.; Mckissick, B. T.; Steinmetz, G. G.

    1979-01-01

    A recent modification of the methodology of profile analysis, which allows the testing for differences between two functions as a whole with a single test, rather than point by point with multiple tests is discussed. The modification is applied to the examination of the issue of motion/no motion conditions as shown by the lateral deviation curve as a function of engine cut speed of a piloted 737-100 simulator. The results of this application are presented along with those of more conventional statistical test procedures on the same simulator data.

  20. Real and Artificial Differential Item Functioning

    ERIC Educational Resources Information Center

    Andrich, David; Hagquist, Curt

    2012-01-01

    The literature in modern test theory on procedures for identifying items with differential item functioning (DIF) among two groups of persons includes the Mantel-Haenszel (MH) procedure. Generally, it is not recognized explicitly that if there is real DIF in some items which favor one group, then as an artifact of this procedure, artificial DIF…

  1. Track/train dynamics test procedure transfer function test

    NASA Technical Reports Server (NTRS)

    Vigil, R. A.

    1975-01-01

    A transfer function vibration test was made on an 80 ton open hopper freight car in an effort to obtain validation data on the car's nonlinear elastic model. Test configuration, handling, test facilities, test operations, and data acquisition/reduction activities necessary to meet the conditions of test requirements are given.

  2. Formulating the Rasch Differential Item Functioning Model under the Marginal Maximum Likelihood Estimation Context and Its Comparison with Mantel-Haenszel Procedure in Short Test and Small Sample Conditions

    ERIC Educational Resources Information Center

    Paek, Insu; Wilson, Mark

    2011-01-01

    This study elaborates the Rasch differential item functioning (DIF) model formulation under the marginal maximum likelihood estimation context. Also, the Rasch DIF model performance was examined and compared with the Mantel-Haenszel (MH) procedure in small sample and short test length conditions through simulations. The theoretically known…

  3. Evaluation plan for space station network interface units

    NASA Technical Reports Server (NTRS)

    Weaver, Alfred C.

    1990-01-01

    Outlined here is a procedure for evaluating network interface units (NIUs) produced for the Space Station program. The procedures should be equally applicable to the data management system (DMS) testbed NIUs produced by Honeywell and IBM. The evaluation procedures are divided into four areas. Performance measurement tools are hardware and software that must be developed in order to evaluate NIU performance. Performance tests are a series of tests, each of which documents some specific characteristic of NIU and/or network performance. In general, these performance tests quantify the speed, capacity, latency, and reliability of message transmission under a wide variety of conditions. Functionality tests are a series of tests and code inspections that demonstrate the functionality of the particular subset of ISO protocols which have been implemented in a given NIU. Conformance tests are a series of tests which would expose whether or not selected features within the ISO protocols are present and interoperable.

  4. Assessing the Item Response Theory with Covariate (IRT-C) Procedure for Ascertaining Differential Item Functioning

    ERIC Educational Resources Information Center

    Tay, Louis; Vermunt, Jeroen K.; Wang, Chun

    2013-01-01

    We evaluate the item response theory with covariates (IRT-C) procedure for assessing differential item functioning (DIF) without preknowledge of anchor items (Tay, Newman, & Vermunt, 2011). This procedure begins with a fully constrained baseline model, and candidate items are tested for uniform and/or nonuniform DIF using the Wald statistic.…

  5. Using Interactive Computing to Expand Intelligence Testing: A Critique and Prospectus.

    ERIC Educational Resources Information Center

    Hunt, Earl; Pellegrino, James

    1985-01-01

    There are economic advantages in using microcomputers as automated testing stations for measuring aptitude and intelligence. Microcomputers also make it possible to expand and modify testing procedures for psychological functions included in conventional tests and to test psychological functions not generally assessed by conventional tests, such…

  6. Intercorrelation of P and Pn Recordings for the North Korean Nuclear Tests

    NASA Astrophysics Data System (ADS)

    Lay, T.; Voytan, D.; Ohman, J.

    2017-12-01

    The relative waveform analysis procedure called Intercorrelation is applied to Pn and P waveforms at regional and teleseismic distances, respectively, for the 5 underground nuclear tests at the North Korean nuclear test site. Intercorrelation is a waveform equalization procedure that parameterizes the effective source function for a given explosion, including the reduced velocity potential convolved with a simplified Green's function that accounts for the free surface reflections (pPn and pP), and possibly additional arrivals such as spall. The source function for one event is convolved with the signal at a given station for a second event, and the recording at the same station for the first event is convolved with the source function for the second event. This procedure eliminates the need to predict the complex receiver function effects at the station, which are typically not well-known for short-period response. The parameters of the source function representation are yield and burial depth, and an explosion source model is required. Here we use the Mueller-Murphy representation of the explosion reduced velocity potential, which explicitly depends on yield and burial depth. We then search over yield and burial depth ranges for both events, constrained by a priori information about reasonable ranges of parameters, to optimize the simultaneous match of multiple station signals for the two events. This procedure, applied to the apparently overburied North Korean nuclear tests (no indications of spall complexity), assuming simple free surface interactions (elastic reflection from a flat surface), provides excellent waveform equalization for all combinations of 5 nuclear tests.

  7. A Study of Platelet Inhibition, Using a 'Point of Care' Platelet Function Test, following Primary Percutaneous Coronary Intervention for ST-Elevation Myocardial Infarction [PINPOINT-PPCI].

    PubMed

    Johnson, Thomas W; Mumford, Andrew D; Scott, Lauren J; Mundell, Stuart; Butler, Mark; Strange, Julian W; Rogers, Chris A; Reeves, Barnaby C; Baumbach, Andreas

    2015-01-01

    Rapid coronary recanalization following ST-elevation myocardial infarction (STEMI) requires effective anti-platelet and anti-thrombotic therapies. This study tested the impact of door to end of procedure ('door-to-end') time and baseline platelet activity on platelet inhibition within 24hours post-STEMI. 108 patients, treated with prasugrel and procedural bivalirudin, underwent Multiplate® platelet function testing at baseline, 0, 1, 2 and 24hours post-procedure. Major adverse cardiac events (MACE), bleeding and stent thrombosis (ST) were recorded. Baseline ADP activity was high (88.3U [71.8-109.0]), procedural time and consequently bivalirudin infusion duration were short (median door-to-end time 55minutes [40-70] and infusion duration 30minutes [20-42]). Baseline ADP was observed to influence all subsequent measurements of ADP activity, whereas door-to-end time only influenced ADP immediately post-procedure. High residual platelet reactivity (HRPR ADP>46.8U) was observed in 75% of patients immediately post-procedure and persisted in 24% of patients at 2hours. Five patients suffered in-hospital MACE (4.6%). Acute ST occurred in 4 patients, all were <120mins post-procedure and had HRPR. No significant bleeding was observed. In a post-hoc analysis, pre-procedural morphine use was associated with significantly higher ADP activity following intervention. Baseline platelet function, time to STEMI treatment and opiate use all significantly influence immediate post-procedural platelet activity.

  8. An Analysis of Individual Differences in Recognizing Monosyllabic Words Under the Speech Intelligibility Index Framework

    PubMed Central

    Shen, Yi; Kern, Allison B.

    2018-01-01

    Individual differences in the recognition of monosyllabic words, either in isolation (NU6 test) or in sentence context (SPIN test), were investigated under the theoretical framework of the speech intelligibility index (SII). An adaptive psychophysical procedure, namely the quick-band-importance-function procedure, was developed to enable the fitting of the SII model to individual listeners. Using this procedure, the band importance function (i.e., the relative weights of speech information across the spectrum) and the link function relating the SII to recognition scores can be simultaneously estimated while requiring only 200 to 300 trials of testing. Octave-frequency band importance functions and link functions were estimated separately for NU6 and SPIN materials from 30 normal-hearing listeners who were naïve to speech recognition experiments. For each type of speech material, considerable individual differences in the spectral weights were observed in some but not all frequency regions. At frequencies where the greatest intersubject variability was found, the spectral weights were correlated between the two speech materials, suggesting that the variability in spectral weights reflected listener-originated factors. PMID:29532711

  9. Safety validation test equipment operation

    NASA Astrophysics Data System (ADS)

    Kurosaki, Tadaaki; Watanabe, Takashi

    1992-08-01

    An overview of the activities conducted on safety validation test equipment operation for materials used for NASA manned missions is presented. Safety validation tests, such as flammability, odor, offgassing, and so forth were conducted in accordance with NASA-NHB-8060.1C using test subjects common with those used by NASA, and the equipment used were qualified for their functions and performances in accordance with NASDA-CR-99124 'Safety Validation Test Qualification Procedures.' Test procedure systems were established by preparing 'Common Procedures for Safety Validation Test' as well as test procedures for flammability, offgassing, and odor tests. The test operation organization chaired by the General Manager of the Parts and Material Laboratory of NASDA (National Space Development Agency of Japan) was established, and the test leaders and operators in the organization were qualified in accordance with the specified procedures. One-hundred-one tests had been conducted so far by the Parts and Material Laboratory according to the request submitted by the manufacturers through the Space Station Group and the Safety and Product Assurance for Manned Systems Office.

  10. The multicategory case of the sequential Bayesian pixel selection and estimation procedure

    NASA Technical Reports Server (NTRS)

    Pore, M. D.; Dennis, T. B. (Principal Investigator)

    1980-01-01

    A Bayesian technique for stratified proportion estimation and a sampling based on minimizing the mean squared error of this estimator were developed and tested on LANDSAT multispectral scanner data using the beta density function to model the prior distribution in the two-class case. An extention of this procedure to the k-class case is considered. A generalization of the beta function is shown to be a density function for the general case which allows the procedure to be extended.

  11. One-sided truncated sequential t-test: application to natural resource sampling

    Treesearch

    Gary W. Fowler; William G. O' Regan

    1974-01-01

    A new procedure for constructing one-sided truncated sequential t-tests and its application to natural resource sampling are described. Monte Carlo procedures were used to develop a series of one-sided truncated sequential t-tests and the associated approximations to the operating characteristic and average sample number functions. Different truncation points and...

  12. Project W-314 acceptance test report HNF-4647 for HNF-4646 241-B pit leak detection ANB-WT-LDSTA-231 for project W-314

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HAMMERS, J.S.

    The purpose of the test was to verify that the AN Tank Farm B Pit Leak Detector components are functionally integrated and operate in accordance with engineering design specifications. The Acceptance Test Procedure HNF-4646,241-AN-B-Pit Leak Detection ANB-WT-LDSTA-231 was conducted between 26 June and 02 July 1999 at the 200E AN Tank Farm. The test has been completed with no open test exceptions. The test was conducted prior to final engineering ''as built'' activities being completed this had no impact on the procedure or test results. All components, identified in the procedure were found to be labeled and identified as writtenmore » in the procedure.« less

  13. A Generalized Logistic Regression Procedure to Detect Differential Item Functioning among Multiple Groups

    ERIC Educational Resources Information Center

    Magis, David; Raiche, Gilles; Beland, Sebastien; Gerard, Paul

    2011-01-01

    We present an extension of the logistic regression procedure to identify dichotomous differential item functioning (DIF) in the presence of more than two groups of respondents. Starting from the usual framework of a single focal group, we propose a general approach to estimate the item response functions in each group and to test for the presence…

  14. Experiments with Cloze Procedure

    ERIC Educational Resources Information Center

    Evans, Gordon; Haastrup, Kirsten

    1976-01-01

    The Nordic Test Development Group prepared proficiency tests of English designed to provide reliable information on which to base decisions as to whether a candidate would be able to function in a job as described or whether he could be trained to do so. Two subtests used a modified cloze procedure. (Author/CFM)

  15. QUEST+: A general multidimensional Bayesian adaptive psychometric method.

    PubMed

    Watson, Andrew B

    2017-03-01

    QUEST+ is a Bayesian adaptive psychometric testing method that allows an arbitrary number of stimulus dimensions, psychometric function parameters, and trial outcomes. It is a generalization and extension of the original QUEST procedure and incorporates many subsequent developments in the area of parametric adaptive testing. With a single procedure, it is possible to implement a wide variety of experimental designs, including conventional threshold measurement; measurement of psychometric function parameters, such as slope and lapse; estimation of the contrast sensitivity function; measurement of increment threshold functions; measurement of noise-masking functions; Thurstone scale estimation using pair comparisons; and categorical ratings on linear and circular stimulus dimensions. QUEST+ provides a general method to accelerate data collection in many areas of cognitive and perceptual science.

  16. The Contribution of Functional Near-Infrared Spectroscopy (fNIRS) to the Presurgical Assessment of Language Function in Children

    ERIC Educational Resources Information Center

    Gallagher, Anne; Beland, Renee; Lassonde, Maryse

    2012-01-01

    Before performing neurosurgery, an exhaustive presurgical assessment is required, usually including an investigation of language cerebral lateralization. Among the available procedures, the intracarotid amobarbital test (IAT) was formerly the most widely used. However, this procedure has many limitations: it is invasive and potentially traumatic,…

  17. 40 CFR 1066.215 - Summary of verification procedures for chassis dynamometers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.215 Summary... judgment. (c) Automated dynamometer verifications and calibrations. In some cases, dynamometers are... specified in this subpart. You may use these automated functions instead of following the procedures we...

  18. Scale Comparability between Nonaccommodated and Accommodated Forms of a Statewide High School Assessment: Assessment Using "l[subscript z]" Person-Fit

    ERIC Educational Resources Information Center

    Seo, Dong Gi; Hao, Shiqi

    2016-01-01

    Differential item/test functioning (DIF/DTF) are routine procedures to detect item/test unfairness as an explanation for group performance difference. However, unequal sample sizes and small sample sizes have an impact on the statistical power of the DIF/DTF detection procedures. Furthermore, DIF/DTF cannot be used for two test forms without…

  19. Comparison of IRT Likelihood Ratio Test and Logistic Regression DIF Detection Procedures

    ERIC Educational Resources Information Center

    Atar, Burcu; Kamata, Akihito

    2011-01-01

    The Type I error rates and the power of IRT likelihood ratio test and cumulative logit ordinal logistic regression procedures in detecting differential item functioning (DIF) for polytomously scored items were investigated in this Monte Carlo simulation study. For this purpose, 54 simulation conditions (combinations of 3 sample sizes, 2 sample…

  20. Effect of Purification Procedures on DIF Analysis in IRTPRO

    ERIC Educational Resources Information Center

    Fikis, David R. J.; Oshima, T. C.

    2017-01-01

    Purification of the test has been a well-accepted procedure in enhancing the performance of tests for differential item functioning (DIF). As defined by Lord, purification requires reestimation of ability parameters after removing DIF items before conducting the final DIF analysis. IRTPRO 3 is a recently updated program for analyses in item…

  1. ENRAF Series 854 Advanced Technology Gauge (ATG) Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HUBER, J.H.

    1999-08-17

    This procedure provides acceptance testing for Enraf Series 854 level gauges used to monitor levels in Hanford Waste Storage Tanks. The test will verify that the gauge functions according to the manufacturer's instructions and specifications and is properly setup prior to being delivered to the tank farm area. This ATP does not set up the gauge for any specific tank, but is generalized to permit testing the gauge prior to installation package preparation.

  2. 75 FR 22846 - Petition for Modification

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-30

    ... establish the requirements and procedures for filing petitions for modification. II. Petition for... dust covers, weekly inspection and functional testing of the complete deluge-type water spray system...: (1) Weekly inspection and functional tests are conducted of its complete deluge- type water spray...

  3. Procedure for estimating stability and control parameters from flight test data by using maximum likelihood methods employing a real-time digital system

    NASA Technical Reports Server (NTRS)

    Grove, R. D.; Bowles, R. L.; Mayhew, S. C.

    1972-01-01

    A maximum likelihood parameter estimation procedure and program were developed for the extraction of the stability and control derivatives of aircraft from flight test data. Nonlinear six-degree-of-freedom equations describing aircraft dynamics were used to derive sensitivity equations for quasilinearization. The maximum likelihood function with quasilinearization was used to derive the parameter change equations, the covariance matrices for the parameters and measurement noise, and the performance index function. The maximum likelihood estimator was mechanized into an iterative estimation procedure utilizing a real time digital computer and graphic display system. This program was developed for 8 measured state variables and 40 parameters. Test cases were conducted with simulated data for validation of the estimation procedure and program. The program was applied to a V/STOL tilt wing aircraft, a military fighter airplane, and a light single engine airplane. The particular nonlinear equations of motion, derivation of the sensitivity equations, addition of accelerations into the algorithm, operational features of the real time digital system, and test cases are described.

  4. Assessment methods for rehabilitation.

    PubMed

    Biefang, S; Potthoff, P

    1995-09-01

    Diagnostics and evaluation in medical rehabilitation should be based on methods that are as objective as possible. In this context quantitative methods are an important precondition. We conducted for the German Pensions Insurance Institutions (which are in charge of the medical and vocational rehabilitation of workers and employees) a survey on assessment methods for rehabilitation which included an evaluation of American literature, with the aim to indicate procedures that can be considered for adaptation in Germany and to define further research requirements. The survey identified: (1) standardized procedures and instrumented tests for the assessment of musculoskeletal, cardiopulmonary and neurophysiological function; (2) personality, intelligence, achievement, neuropsychological and alcoholism screening tests for the assessment of mental or cognitive function; (3) rating scales and self-administered questionnaires for the assessment of Activities of Daily Living and Instrumental Activities of Daily Living (ADL/IADL Scales); (4) generic profiles and indexes as well as disease-specific measures for the assessment of health-related quality of life and health status; and (5) rating scales for vocational assessment. German equivalents or German versions exist only for a part of the procedures identified. Translation and testing of Anglo-Saxon procedures should have priority over the development of new German methods. The following procedures will be taken into account: (a) instrumented tests for physical function, (b) IADL Scales, (c) generic indexes of health-related quality of life, (d) specific quality of life and health status measures for disorders of the circulatory system, metabolic system, digestive organs, respiratory tract and for cancer, and (e) vocational rating scales.

  5. New techniques for test development for tactical auto-pilots using microprocessors

    NASA Astrophysics Data System (ADS)

    Shemeta, E. H.

    1980-07-01

    This paper reports on a demonstration of the application of the method to generate system level tests for a typical tactical missile autopilot. The test algorithms are based on the autopilot control law. When loaded on the tester with appropriate control information, the complete autopilot is tested to establish if the specified control law requirements are met. Thus, the test procedure not only checks to see if the hardware is functional, but also checks the operational software. The technique also uses a 'learning' mode to allow minor timing or functional deviations from the expected responses to be incorporated in the test procedures. A potential application of this test development technique is the extraction of production test data for the various subassemblies. The technique will 'learn' the input-output patterns forming the basis for developement and production tests. If successful, these new techniques should allow the test development process to keep pace with semiconductor progress.

  6. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  7. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  8. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  9. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  10. 49 CFR 40.307 - What is the SAP's function in prescribing the employee's follow-up tests?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What is the SAP's function in prescribing the employee's follow-up tests? 40.307 Section 40.307 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  11. An Alternative Methodology for Creating Parallel Test Forms Using the IRT Information Function.

    ERIC Educational Resources Information Center

    Ackerman, Terry A.

    The purpose of this paper is to report results on the development of a new computer-assisted methodology for creating parallel test forms using the item response theory (IRT) information function. Recently, several researchers have approached test construction from a mathematical programming perspective. However, these procedures require…

  12. Procedures to develop a computerized adaptive test to assess patient-reported physical functioning.

    PubMed

    McCabe, Erin; Gross, Douglas P; Bulut, Okan

    2018-06-07

    The purpose of this paper is to demonstrate the procedures to develop and implement a computerized adaptive patient-reported outcome (PRO) measure using secondary analysis of a dataset and items from fixed-format legacy measures. We conducted secondary analysis of a dataset of responses from 1429 persons with work-related lower extremity impairment. We calibrated three measures of physical functioning on the same metric, based on item response theory (IRT). We evaluated efficiency and measurement precision of various computerized adaptive test (CAT) designs using computer simulations. IRT and confirmatory factor analyses support combining the items from the three scales for a CAT item bank of 31 items. The item parameters for IRT were calculated using the generalized partial credit model. CAT simulations show that reducing the test length from the full 31 items to a maximum test length of 8 items, or 20 items is possible without a significant loss of information (95, 99% correlation with legacy measure scores). We demonstrated feasibility and efficiency of using CAT for PRO measurement of physical functioning. The procedures we outlined are straightforward, and can be applied to other PRO measures. Additionally, we have included all the information necessary to implement the CAT of physical functioning in the electronic supplementary material of this paper.

  13. qPR: An adaptive partial-report procedure based on Bayesian inference.

    PubMed

    Baek, Jongsoo; Lesmes, Luis Andres; Lu, Zhong-Lin

    2016-08-01

    Iconic memory is best assessed with the partial report procedure in which an array of letters appears briefly on the screen and a poststimulus cue directs the observer to report the identity of the cued letter(s). Typically, 6-8 cue delays or 600-800 trials are tested to measure the iconic memory decay function. Here we develop a quick partial report, or qPR, procedure based on a Bayesian adaptive framework to estimate the iconic memory decay function with much reduced testing time. The iconic memory decay function is characterized by an exponential function and a joint probability distribution of its three parameters. Starting with a prior of the parameters, the method selects the stimulus to maximize the expected information gain in the next test trial. It then updates the posterior probability distribution of the parameters based on the observer's response using Bayesian inference. The procedure is reiterated until either the total number of trials or the precision of the parameter estimates reaches a certain criterion. Simulation studies showed that only 100 trials were necessary to reach an average absolute bias of 0.026 and a precision of 0.070 (both in terms of probability correct). A psychophysical validation experiment showed that estimates of the iconic memory decay function obtained with 100 qPR trials exhibited good precision (the half width of the 68.2% credible interval = 0.055) and excellent agreement with those obtained with 1,600 trials of the conventional method of constant stimuli procedure (RMSE = 0.063). Quick partial-report relieves the data collection burden in characterizing iconic memory and makes it possible to assess iconic memory in clinical populations.

  14. qPR: An adaptive partial-report procedure based on Bayesian inference

    PubMed Central

    Baek, Jongsoo; Lesmes, Luis Andres; Lu, Zhong-Lin

    2016-01-01

    Iconic memory is best assessed with the partial report procedure in which an array of letters appears briefly on the screen and a poststimulus cue directs the observer to report the identity of the cued letter(s). Typically, 6–8 cue delays or 600–800 trials are tested to measure the iconic memory decay function. Here we develop a quick partial report, or qPR, procedure based on a Bayesian adaptive framework to estimate the iconic memory decay function with much reduced testing time. The iconic memory decay function is characterized by an exponential function and a joint probability distribution of its three parameters. Starting with a prior of the parameters, the method selects the stimulus to maximize the expected information gain in the next test trial. It then updates the posterior probability distribution of the parameters based on the observer's response using Bayesian inference. The procedure is reiterated until either the total number of trials or the precision of the parameter estimates reaches a certain criterion. Simulation studies showed that only 100 trials were necessary to reach an average absolute bias of 0.026 and a precision of 0.070 (both in terms of probability correct). A psychophysical validation experiment showed that estimates of the iconic memory decay function obtained with 100 qPR trials exhibited good precision (the half width of the 68.2% credible interval = 0.055) and excellent agreement with those obtained with 1,600 trials of the conventional method of constant stimuli procedure (RMSE = 0.063). Quick partial-report relieves the data collection burden in characterizing iconic memory and makes it possible to assess iconic memory in clinical populations. PMID:27580045

  15. A posteriori model validation for the temporal order of directed functional connectivity maps.

    PubMed

    Beltz, Adriene M; Molenaar, Peter C M

    2015-01-01

    A posteriori model validation for the temporal order of neural directed functional connectivity maps is rare. This is striking because models that require sequential independence among residuals are regularly implemented. The aim of the current study was (a) to apply to directed functional connectivity maps of functional magnetic resonance imaging data an a posteriori model validation procedure (i.e., white noise tests of one-step-ahead prediction errors combined with decision criteria for revising the maps based upon Lagrange Multiplier tests), and (b) to demonstrate how the procedure applies to single-subject simulated, single-subject task-related, and multi-subject resting state data. Directed functional connectivity was determined by the unified structural equation model family of approaches in order to map contemporaneous and first order lagged connections among brain regions at the group- and individual-levels while incorporating external input, then white noise tests were run. Findings revealed that the validation procedure successfully detected unmodeled sequential dependencies among residuals and recovered higher order (greater than one) simulated connections, and that the procedure can accommodate task-related input. Findings also revealed that lags greater than one were present in resting state data: With a group-level network that contained only contemporaneous and first order connections, 44% of subjects required second order, individual-level connections in order to obtain maps with white noise residuals. Results have broad methodological relevance (e.g., temporal validation is necessary after directed functional connectivity analyses because the presence of unmodeled higher order sequential dependencies may bias parameter estimates) and substantive implications (e.g., higher order lags may be common in resting state data).

  16. Examining Measurement Invariance and Differential Item Functioning with Discrete Latent Construct Indicators: A Note on a Multiple Testing Procedure

    ERIC Educational Resources Information Center

    Raykov, Tenko; Dimitrov, Dimiter M.; Marcoulides, George A.; Li, Tatyana; Menold, Natalja

    2018-01-01

    A latent variable modeling method for studying measurement invariance when evaluating latent constructs with multiple binary or binary scored items with no guessing is outlined. The approach extends the continuous indicator procedure described by Raykov and colleagues, utilizes similarly the false discovery rate approach to multiple testing, and…

  17. Using Cochran's Z Statistic to Test the Kernel-Smoothed Item Response Function Differences between Focal and Reference Groups

    ERIC Educational Resources Information Center

    Zheng, Yinggan; Gierl, Mark J.; Cui, Ying

    2010-01-01

    This study combined the kernel smoothing procedure and a nonparametric differential item functioning statistic--Cochran's Z--to statistically test the difference between the kernel-smoothed item response functions for reference and focal groups. Simulation studies were conducted to investigate the Type I error and power of the proposed…

  18. 77 FR 28805 - Energy Conservation Program: Test Procedures for Microwave Ovens

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-16

    ...On November 23, 2011, the U.S. Department of Energy (DOE) issued a supplemental notice of proposed rulemaking (SNOPR) to amend the test procedures for microwave ovens. That SNOPR proposed amendments to the DOE test procedure to incorporate provisions from the International Electrotechnical Commission (IEC) Standard 62301, ``Household electrical appliances--Measurement of standby power,'' Edition 2.0 2011-01 (IEC Standard 62301 (Second Edition)). Today's SNOPR proposes additional provisions for measuring the standby mode and off mode energy use of products that combine a microwave oven with other appliance functionality, as well as minor technical clarifications.

  19. Design and implementation of Ada programs to facilitate automated testing

    NASA Technical Reports Server (NTRS)

    Dean, Jack; Fox, Barry; Oropeza, Michael

    1991-01-01

    An automated method utilized to test the software components of COMPASS, an interactive computer aided scheduling system, is presented. Each package of this system introduces a private type, and works to construct instances of that type, along with read and write routines for that type. Generic procedures that can generate test drivers for these functions are given and show how the test drivers can read from a test data file the functions to call, the arguments for those functions, what the anticipated result should be, and whether an exception should be raised for the function given the arguments.

  20. Analyzing the test process using structural coverage

    NASA Technical Reports Server (NTRS)

    Ramsey, James; Basili, Victor R.

    1985-01-01

    A large, commercially developed FORTRAN program was modified to produce structural coverage metrics. The modified program was executed on a set of functionally generated acceptance tests and a large sample of operational usage cases. The resulting structural coverage metrics are combined with fault and error data to evaluate structural coverage. It was shown that in the software environment the functionally generated tests seem to be a good approximation of operational use. The relative proportions of the exercised statement subclasses change as the structural coverage of the program increases. A method was also proposed for evaluating if two sets of input data exercise a program in a similar manner. Evidence was provided that implies that in this environment, faults revealed in a procedure are independent of the number of times the procedure is executed and that it may be reasonable to use procedure coverage in software models that use statement coverage. Finally, the evidence suggests that it may be possible to use structural coverage to aid in the management of the acceptance test processed.

  1. A hierarchical Bayesian approach to adaptive vision testing: A case study with the contrast sensitivity function.

    PubMed

    Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A; Lu, Zhong-Lin; Myung, Jay I

    2016-01-01

    Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias.

  2. A hierarchical Bayesian approach to adaptive vision testing: A case study with the contrast sensitivity function

    PubMed Central

    Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A.; Lu, Zhong-Lin; Myung, Jay I.

    2016-01-01

    Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias. PMID:27105061

  3. Bayesian estimation of the transmissivity spatial structure from pumping test data

    NASA Astrophysics Data System (ADS)

    Demir, Mehmet Taner; Copty, Nadim K.; Trinchero, Paolo; Sanchez-Vila, Xavier

    2017-06-01

    Estimating the statistical parameters (mean, variance, and integral scale) that define the spatial structure of the transmissivity or hydraulic conductivity fields is a fundamental step for the accurate prediction of subsurface flow and contaminant transport. In practice, the determination of the spatial structure is a challenge because of spatial heterogeneity and data scarcity. In this paper, we describe a novel approach that uses time drawdown data from multiple pumping tests to determine the transmissivity statistical spatial structure. The method builds on the pumping test interpretation procedure of Copty et al. (2011) (Continuous Derivation method, CD), which uses the time-drawdown data and its time derivative to estimate apparent transmissivity values as a function of radial distance from the pumping well. A Bayesian approach is then used to infer the statistical parameters of the transmissivity field by combining prior information about the parameters and the likelihood function expressed in terms of radially-dependent apparent transmissivities determined from pumping tests. A major advantage of the proposed Bayesian approach is that the likelihood function is readily determined from randomly generated multiple realizations of the transmissivity field, without the need to solve the groundwater flow equation. Applying the method to synthetically-generated pumping test data, we demonstrate that, through a relatively simple procedure, information on the spatial structure of the transmissivity may be inferred from pumping tests data. It is also shown that the prior parameter distribution has a significant influence on the estimation procedure, given the non-uniqueness of the estimation procedure. Results also indicate that the reliability of the estimated transmissivity statistical parameters increases with the number of available pumping tests.

  4. The child's perspective on discomfort during medical research procedures: a descriptive study.

    PubMed

    Staphorst, Mira S; Benninga, Marc A; Bisschoff, Margriet; Bon, Irma; Busschbach, Jan J V; Diederen, Kay; van Goudoever, Johannes B; Haarman, Eric G; Hunfeld, Joke A M; Jaddoe, Vincent V W; de Jong, Karin J M; de Jongste, Johan C; Kindermann, Angelika; Königs, Marsh; Oosterlaan, Jaap; Passchier, Jan; Pijnenburg, Mariëlle W; Reneman, Liesbeth; Ridder, Lissy de; Tamminga, Hyke G; Tiemeier, Henning W; Timman, Reinier; van de Vathorst, Suzanne

    2017-08-01

    The evaluation of discomfort in paediatric research is scarcely evidence-based. In this study, we make a start in describing children's self-reported discomfort during common medical research procedures and compare this with discomfort during dental check-ups which can be considered as a reference level of a 'minimal discomfort' medical procedure. We exploratory study whether there are associations between age, anxiety-proneness, gender, medical condition, previous experiences and discomfort. We also describe children's suggestions for reducing discomfort. Cross-sectional descriptive study. Paediatric research at three academic hospitals. 357 children with and without illnesses (8-18 years, mean=10.6 years) were enrolled: 307 from paediatric research studies and 50 from dental care. We measured various generic forms of discomfort (nervousness, annoyance, pain, fright, boredom, tiredness) due to six common research procedures: buccal swabs, MRI scans, pulmonary function tests, skin prick tests, ultrasound imaging and venepunctures. Most children reported limited discomfort during the research procedures (means: 1-2.6 on a scale from 1 to 5). Compared with dental check-ups, buccal swab tests, skin prick tests and ultrasound imaging were less discomforting, while MRI scans, venepunctures and pulmonary function tests caused a similar degree of discomfort. 60.3% of the children suggested providing distraction by showing movies to reduce discomfort. The exploratory analyses suggested a positive association between anxiety-proneness and discomfort. The findings of this study support the acceptability of participation of children in the studied research procedures, which stimulates evidence-based research practice. Furthermore, the present study can be considered as a first step in providing benchmarks for discomfort of procedures in paediatric research. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. The child's perspective on discomfort during medical research procedures: a descriptive study

    PubMed Central

    Staphorst, Mira S; Benninga, Marc A; Bisschoff, Margriet; Bon, Irma; Busschbach, Jan J V; Diederen, Kay; van Goudoever, Johannes B; Haarman, Eric G; Hunfeld, Joke A M; Jaddoe, Vincent V W; de Jong, Karin J M; de Jongste, Johan C; Kindermann, Angelika; Königs, Marsh; Oosterlaan, Jaap; Passchier, Jan; Pijnenburg, Mariëlle W; Reneman, Liesbeth; de Ridder, Lissy; Tamminga, Hyke G; Tiemeier, Henning W; Timman, Reinier; van de Vathorst, Suzanne

    2017-01-01

    Objective The evaluation of discomfort in paediatric research is scarcely evidence-based. In this study, we make a start in describing children's self-reported discomfort during common medical research procedures and compare this with discomfort during dental check-ups which can be considered as a reference level of a ‘minimal discomfort’ medical procedure. We exploratory study whether there are associations between age, anxiety-proneness, gender, medical condition, previous experiences and discomfort. We also describe children's suggestions for reducing discomfort. Design Cross-sectional descriptive study. Setting Paediatric research at three academic hospitals. Patients 357 children with and without illnesses (8–18 years, mean=10.6 years) were enrolled: 307 from paediatric research studies and 50 from dental care. Main outcome measures We measured various generic forms of discomfort (nervousness, annoyance, pain, fright, boredom, tiredness) due to six common research procedures: buccal swabs, MRI scans, pulmonary function tests, skin prick tests, ultrasound imaging and venepunctures. Results Most children reported limited discomfort during the research procedures (means: 1–2.6 on a scale from 1 to 5). Compared with dental check-ups, buccal swab tests, skin prick tests and ultrasound imaging were less discomforting, while MRI scans, venepunctures and pulmonary function tests caused a similar degree of discomfort. 60.3% of the children suggested providing distraction by showing movies to reduce discomfort. The exploratory analyses suggested a positive association between anxiety-proneness and discomfort. Conclusions The findings of this study support the acceptability of participation of children in the studied research procedures, which stimulates evidence-based research practice. Furthermore, the present study can be considered as a first step in providing benchmarks for discomfort of procedures in paediatric research. PMID:28765130

  6. A function-based approach to cockpit procedure aids

    NASA Technical Reports Server (NTRS)

    Phatak, Anil V.; Jain, Parveen; Palmer, Everett

    1990-01-01

    The objective of this research is to develop and test a cockpit procedural aid that can compose and present procedures that are appropriate for the given flight situation. The procedure would indicate the status of the aircraft engineering systems, and the environmental conditions. Prescribed procedures already exist for normal as well as for a number of non-normal and emergency situations, and can be presented to the crew using an interactive cockpit display. However, no procedures are prescribed or recommended for a host of plausible flight situations involving multiple malfunctions compounded by adverse environmental conditions. Under these circumstances, the cockpit procedural aid must review the prescribed procedures for the individual malfunction (when available), evaluate the alternatives or options, and present one or more composite procedures (prioritized or unprioritized) in response to the given situation. A top-down function-based conceptual approach towards composing and presenting cockpit procedures is being investigated. This approach is based upon the thought process that an operating crew must go through while attempting to meet the flight objectives given the current flight situation. In order to accomplish the flight objectives, certain critical functions must be maintained during each phase of the flight, using the appropriate procedures or success paths. The viability of these procedures depends upon the availability of required resources. If resources available are not sufficient to meet the requirements, alternative procedures (success paths) using the available resources must be constructed to maintain the critical functions and the corresponding objectives. If no success path exists that can satisfy the critical functions/objectives, then the next level of critical functions/objectives must be selected and the process repeated. Information is given in viewgraph form.

  7. DIFAS: Differential Item Functioning Analysis System. Computer Program Exchange

    ERIC Educational Resources Information Center

    Penfield, Randall D.

    2005-01-01

    Differential item functioning (DIF) is an important consideration in assessing the validity of test scores (Camilli & Shepard, 1994). A variety of statistical procedures have been developed to assess DIF in tests of dichotomous (Hills, 1989; Millsap & Everson, 1993) and polytomous (Penfield & Lam, 2000; Potenza & Dorans, 1995) items. Some of these…

  8. AN EVALUATION OF HEURISTICS FOR THRESHOLD-FUNCTION TEST-SYNTHESIS,

    DTIC Science & Technology

    Linear programming offers the most attractive procedure for testing and obtaining optimal threshold gate realizations for functions generated in...The design of the experiments may be of general interest to students of automatic problem solving; the results should be of interest in threshold logic and linear programming. (Author)

  9. 49 CFR 40.129 - What are the MRO's functions in reviewing laboratory confirmed non-negative drug test results?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What are the MRO's functions in reviewing laboratory confirmed non-negative drug test results? 40.129 Section 40.129 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Medical Review Officers and the Verification Proces...

  10. 49 CFR 40.127 - What are the MRO's functions in reviewing negative test results?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What are the MRO's functions in reviewing negative test results? 40.127 Section 40.127 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Medical Review Officers and the Verification Process § 40.127 What are the MRO's...

  11. Determination of the thermal stability of fluids by tensimetry - Instrumentation and procedure

    NASA Technical Reports Server (NTRS)

    Helmick, Larry S.; Jones, William R., Jr.

    1990-01-01

    A computerized tensimeter and experimental procedure for determination of the thermal decomposition temperature (T sub d) of perfluoro alkylethers were developed and tested. Both the apparatus and the procedure are described in detail. Results of testing with bis(2-ethylhexyl) phthalate and trimethylolpropane triheptanoate demonstrate that the reciprocal of the decomposition temperature is a linear function of the logarithm of the gas volume/heated liquid volume ratio. The T sub d obtained for each compound at a gas volume/heated liquid volume ration of one was similar to the value previously reported using an isoteniscope technique. Results of testing with a polymer of hexafluoropropylene oxide demonstrate that this instrument and procedure can be used to determine the T sub d of perfluoro alkylethers.

  12. Determination of the thermal stability of perfluoroalkylethers by tensimetry: Instrumentation and Procedure

    NASA Technical Reports Server (NTRS)

    Helmick, Larry S.; Jones, William R., Jr.

    1989-01-01

    A computerized tensimeter and experimental procedure for determination of the thermal decomposition temperature (T sub d) of perfluoro alkylethers were developed and tested. Both the apparatus and the procedure are described in detail. Results of testing with bis(2-ethylhexyl) phthalate and trimethylolpropane triheptanoate demonstrate that the reciprocal of the decomposition temperature is a linear function of the logarithm of the gas volume/heated liquid volume ratio. The T sub d obtained for each compound at a gas volume/heated liquid volume ration of one was similar to the value previously reported using an isoteniscope technique. Results of testing with a polymer of hexafluoropropylene oxide demonstrate that this instrument and procedure can be used to determine the T sub d of perfluoroalkylethers.

  13. A posteriori model validation for the temporal order of directed functional connectivity maps

    PubMed Central

    Beltz, Adriene M.; Molenaar, Peter C. M.

    2015-01-01

    A posteriori model validation for the temporal order of neural directed functional connectivity maps is rare. This is striking because models that require sequential independence among residuals are regularly implemented. The aim of the current study was (a) to apply to directed functional connectivity maps of functional magnetic resonance imaging data an a posteriori model validation procedure (i.e., white noise tests of one-step-ahead prediction errors combined with decision criteria for revising the maps based upon Lagrange Multiplier tests), and (b) to demonstrate how the procedure applies to single-subject simulated, single-subject task-related, and multi-subject resting state data. Directed functional connectivity was determined by the unified structural equation model family of approaches in order to map contemporaneous and first order lagged connections among brain regions at the group- and individual-levels while incorporating external input, then white noise tests were run. Findings revealed that the validation procedure successfully detected unmodeled sequential dependencies among residuals and recovered higher order (greater than one) simulated connections, and that the procedure can accommodate task-related input. Findings also revealed that lags greater than one were present in resting state data: With a group-level network that contained only contemporaneous and first order connections, 44% of subjects required second order, individual-level connections in order to obtain maps with white noise residuals. Results have broad methodological relevance (e.g., temporal validation is necessary after directed functional connectivity analyses because the presence of unmodeled higher order sequential dependencies may bias parameter estimates) and substantive implications (e.g., higher order lags may be common in resting state data). PMID:26379489

  14. [Long-term results of the surgical treatment of chronic pancreatitis].

    PubMed

    Padillo Ruiz, F J; Rufián, S; Varo, E; Solorzano, G; Miño, G; Pera Madrazo, C

    1994-08-01

    We analized the long-term results after surgical treatment in 41 patients with chronic pancreatitis. Twenty one of them underwent resection: 19 pancreaticoduodenectomy (11 Whipple procedure and 8 Traverso Longmire); total pancreatectomy (1) and near-total pancreatectomy (1). In the remaining 20 patients a drainage procedure was carried out: Puestow-Duval (5); Partington (7); double derivation: pancreatic and biliar (5); triple derivation: pancreatic, biliar, gastric (2) and Nardi procedure+quisteduodenostomy in one patient. The following were evaluated: persistent pain; chronic alcoholism; nutrition status; exocrine function (syntomatic steatorrea, use of pancreatic enzyme preparation and fecal determination of glucide, protids and lipids) and endocrine function (glucose and insulin levels and glucose oral test). Surgery failed to relieve pain in 15.6% of the patients; failures were associated chronic alcoholism (p < 0.05); 18 patients (44%) required oral pancreatic enzymes. There weren't significant differences between resection and drainage procedures regarding the exocrine function. However, endocrine function was significantly worse (p < 0.05) after pancreaticoduodenectomy than after drainages procedures. Among the late, the endocrine function was better after Partington operation than after the Puestow-Duval.

  15. MyHealthAtVanderbilt: policies and procedures governing patient portal functionality

    PubMed Central

    Rosenbloom, S Trent; Stenner, Shane P; Anders, Shilo; Muse, Sue; Johnson, Kevin B; Jirjis, Jim; Jackson, Gretchen Purcell

    2011-01-01

    Explicit guidelines are needed to develop safe and effective patient portals. This paper proposes general principles, policies, and procedures for patient portal functionality based on MyHealthAtVanderbilt (MHAV), a robust portal for Vanderbilt University Medical Center. We describe policies and procedures designed to govern popular portal functions, address common user concerns, and support adoption. We present the results of our approach as overall and function-specific usage data. Five years after implementation, MHAV has over 129 800 users; 45% have used bi-directional messaging; 52% have viewed test results and 45% have viewed other medical record data; 30% have accessed health education materials; 39% have scheduled appointments; and 29% have managed a medical bill. Our policies and procedures have supported widespread adoption and use of MHAV. We believe other healthcare organizations could employ our general guidelines and lessons learned to facilitate portal implementation and usage. PMID:21807648

  16. Computerized tests to evaluate recovery of cognitive function after deep sedation with propofol and remifentanil for colonoscopy.

    PubMed

    Borrat, Xavier; Ubre, Marta; Risco, Raquel; Gambús, Pedro L; Pedroso, Angela; Iglesias, Aina; Fernandez-Esparrach, Gloria; Ginés, Àngels; Balust, Jaume; Martínez-Palli, Graciela

    2018-03-27

    The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptors of cognitive function. The purpose of the present study was to evaluate the time course of cognitive function recovery after sedation with propofol and remifentanil. A prospective observational double blind clinical study conducted in 34 young healthy adults undergoing elective outpatient colonoscopy under sedation with the combination of propofol and remifentanil using a target controlled infusion system. Cognitive function was measured using a validated battery of computerized cognitive tests (Cogstate™, Melbourne, Australia) at different predefined times: prior to starting sedation (Tbaseline), and then 10 min (T10), 40 min (T40) and 120 min (T120) after the end of colonoscopy. Tests included the assessment of psychomotor function, attention, visual memory and working memory. All colonoscopies were completed (median time: 26 min) without significant adverse events. Patients received a median total dose of propofol and remifentanil of 149 mg and 98 µg, respectively. Psychomotor function and attention declined at T10 but were back to baseline values at T40 for all patients. The magnitude of psychomotor task reduction was large (d = 0.81) however 100% of patients were recovered at T40. Memory related tasks were not affected 10 min after ending sedation. Cognitive impairment in attention and psychomotor function after propofol and remifentanil sedation was significant and large and could be easily detected by computerized cognitive tests. Even though, patients were fully recovered 40 min after ending the procedure. From a cognitive recovery point of view, larger studies should be undertaken to propose adequate criteria for discharge after sedation.

  17. Track/train dynamics test report transfer function test. Volume 1: Test

    NASA Technical Reports Server (NTRS)

    Vigil, R. A.

    1975-01-01

    A description is presented of the transfer function test performed on an open hopper freight car loaded with 80 tons of coal. Test data and a post-test update of the requirements document and test procedure are presented. Included are a statement of the test objective, a description of the test configurations, test facilities, test methods, data acquisition/reduction operations, and a chronological test summary. An index to the data for the three test configurations (X, Y, and Z-axis tests) is presented along with test sequence, run number, test reference, and input parameters.

  18. Acceptance of Personality Interpretations as a Function of Assessment Procedures

    ERIC Educational Resources Information Center

    Snyder, C. R.

    1974-01-01

    The purpose of the two present studies is to ascertain whether differential acceptance of the same general personality interpretation resulted as a function of telling seperate groups of individuals that their interpretation was based on a projective test, an interview, an objective test, or was "generally true of people." (Author)

  19. Explicitly correlated benchmark calculations on C8H8 isomer energy separations: how accurate are DFT, double-hybrid, and composite ab initio procedures?

    NASA Astrophysics Data System (ADS)

    Karton, Amir; Martin, Jan M. L.

    2012-10-01

    Accurate isomerization energies are obtained for a set of 45 C8H8 isomers by means of the high-level, ab initio W1-F12 thermochemical protocol. The 45 isomers involve a range of hydrocarbon functional groups, including (linear and cyclic) polyacetylene, polyyne, and cumulene moieties, as well as aromatic, anti-aromatic, and highly-strained rings. Performance of a variety of DFT functionals for the isomerization energies is evaluated. This proves to be a challenging test: only six of the 56 tested functionals attain root mean square deviations (RMSDs) below 3 kcal mol-1 (the performance of MP2), namely: 2.9 (B972-D), 2.8 (PW6B95), 2.7 (B3PW91-D), 2.2 (PWPB95-D3), 2.1 (ωB97X-D), and 1.2 (DSD-PBEP86) kcal mol-1. Isomers involving highly-strained fused rings or long cumulenic chains provide a 'torture test' for most functionals. Finally, we evaluate the performance of composite procedures (e.g. G4, G4(MP2), CBS-QB3, and CBS-APNO), as well as that of standard ab initio procedures (e.g. MP2, SCS-MP2, MP4, CCSD, and SCS-CCSD). Both connected triples and post-MP4 singles and doubles are important for accurate results. SCS-MP2 actually outperforms MP4(SDQ) for this problem, while SCS-MP3 yields similar performance as CCSD and slightly bests MP4. All the tested empirical composite procedures show excellent performance with RMSDs below 1 kcal mol-1.

  20. Sexual and functional results after creation of a neovagina in women with Mayer-Rokitansky-Küster-Hauser syndrome: a comparison of nonsurgical and surgical procedures.

    PubMed

    Morcel, Karine; Lavoué, Vincent; Jaffre, Frédérique; Paniel, Bernard-Jean; Rouzier, Roman

    2013-07-01

    To compare nonsurgical and surgical procedures for creation of a neovagina in women with Mayer-Rokitansky-Küster-Hauser (MRKH) syndrome in terms of sexual satisfaction. We report a cross-sectional study of 91 women with MRKH syndrome undergoing a neovagina creation procedure. They were members of the French National Association of Women with MRKH syndrome. We analyzed all answers to a questionnaire mailed to each woman. The questionnaire solicited short answers concerning the diagnosis and the neovagina procedure, and included the standardized FSFI (Female Sexual Function Index) questionnaire. All analyses were performed using the chi-squared test and Student's t-test. A p-value of <0.05 was considered statistically significant. Forty women answered the questionnaire. Twenty had been treated by Frank's method (non-surgical group) and 20 had undergone a surgical procedure, sigmoid vaginoplasty (12 cases) or Davidov's technique (8 cases) (surgical group). The mean time after neovagina creation was 7 years (range 1-44 years). The population characteristics did not differ significantly between the nonsurgical and surgical groups. The total FSFI score indicated good and similar functional results in the two groups (25.3±7.5 versus 25.3±8.0). Functional sexual outcomes after nonsurgical and surgical methods were similar. Therefore, the Frank's method should be proposed as first line therapy because it is less invasive than surgical procedures. In the case of failure of this technique or of refusal by the patient, surgical reconstruction may then be offered. Copyright © 2013. Published by Elsevier Ireland Ltd.

  1. Project W-314 acceptance test report HNF-4643 for HNF-4642 241-AN-A valve pit manifold valves and position indication for project W-314

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HAMMERS, J.S.

    1999-09-22

    The purpose of the test was to verify that the AN Tank Farm Manifold Valves can be manually manipulated to the required operating position and that the electrical and visual indications accurately reflect that position. Physical locking devices were also verified to function. The Acceptance Test Procedure HNF-4642, 241-AN-A Valve Pit Manifold Valves and Position Indication was conducted between 23 June and 10 August 1999 at the 200E AN Tank Farm. The test has no open test exceptions. The test was conducted prior to final engineering ''as built'' activities being completed, this had an impact on the procedure and testmore » results, ECN 653752 was written to correct the mismatch between the procedure and actual field conditions. P&ID H-14-100941 was changed via ECN-W-314-4C-120. All components, identified in the procedure, were not found to be labeled and identified as written in the procedure, temporary tags were used for operational identification. A retest of valve ANA-WT-V 318 was required because it was removed from its installed position and modified after testing was completed.« less

  2. The Relationship between Mathematical Induction, Proposition Functions, and Implication Functions

    ERIC Educational Resources Information Center

    Andrew, Lane

    2010-01-01

    In this study, I explored the relationship between mathematical induction ability and proposition and implication functions through a mixed methods approach. Students from three universities (N = 78) and 6 classrooms completed a written assessment testing their conceptual and procedural capabilities with induction and functions. In addition, I…

  3. Effects of Average Signed Area Between Two Item Characteristic Curves and Test Purification Procedures on the DIF Detection via the Mantel-Haenszel Method

    ERIC Educational Resources Information Center

    Wang, Wen-Chung; Su, Ya-Hui

    2004-01-01

    In this study we investigated the effects of the average signed area (ASA) between the item characteristic curves of the reference and focal groups and three test purification procedures on the uniform differential item functioning (DIF) detection via the Mantel-Haenszel (M-H) method through Monte Carlo simulations. The results showed that ASA,…

  4. Two Simple Approaches to Overcome a Problem with the Mantel-Haenszel Statistic: Comments on Wang, Bradlow, Wainer, and Muller (2008)

    ERIC Educational Resources Information Center

    Sinharay, Sandip; Dorans, Neil J.

    2010-01-01

    The Mantel-Haenszel (MH) procedure (Mantel and Haenszel) is a popular method for estimating and testing a common two-factor association parameter in a 2 x 2 x K table. Holland and Holland and Thayer described how to use the procedure to detect differential item functioning (DIF) for tests with dichotomously scored items. Wang, Bradlow, Wainer, and…

  5. Long-term impact of subthalamic stimulation on cognitive function in patients with advanced Parkinson's disease.

    PubMed

    Acera, M; Molano, A; Tijero, B; Bilbao, G; Lambarri, I; Villoria, R; Somme, J; Ruiz de Gopegui, E; Gabilondo, I; Gomez-Esteban, J C

    2017-07-13

    The aim of this study was to evaluate the effects of deep brain stimulation of the subthalamic nucleus (DBS-SN) on cognitive function in patients with Parkinson's disease (PD) 5 years after surgery. We conducted a prospective study including 50 patients with PD who underwent DBS-SN (62.5% were men; mean age of 62.2±8.2 years; mean progression time of 14.1±6.3 years). All patients were assessed before the procedure and at one year after surgery; 40 patients were further followed up until the 5-year mark. Follow-up assessments included the following neuropsychological tests: Mini-Mental State Examination (MMSE), Mattis Dementia Rating Scale (MDRS), letter-number sequencing of the WAIS-III (WAIS-III-LN), clock-drawing test, Rey auditory verbal learning test (RAVLT), Benton Visual Retention Test (BVRT), Judgment of Line Orientation (JLO) test, FAS Phonemic Verbal Fluency Test, Stroop test, and the Montgomery-Asberg Depression Rating Scale (MADRS). Patients were found to score lower on the MMSE (-0.89%), clock-drawing test (-2.61%), MDRS (-1.72%), and especially phonemic (-13.28%) and sematic verbal fluency tests (-12.40%) at one year after surgery. Delayed recall on the RAVLT worsened one year after the procedure (-10.12%). At 5 years, impairment affected mainly verbal fluency; scores decreased an additional 16.10% and 16.60% in semantic and phonemic verbal fluency, respectively. Moderate decreases were observed in immediate recall (-16.87%), WAIS-III-LN (-16.67%), and JLO test (-11.56%). In our sample, DBS-SN did not result in global cognitive impairment 5 years after surgery. Verbal function was found to be significantly impaired one year after the procedure. Impaired learning and visuospatial function may be attributed to degeneration associated with PD. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. A novel tablet computer platform for advanced language mapping during awake craniotomy procedures.

    PubMed

    Morrison, Melanie A; Tam, Fred; Garavaglia, Marco M; Golestanirad, Laleh; Hare, Gregory M T; Cusimano, Michael D; Schweizer, Tom A; Das, Sunit; Graham, Simon J

    2016-04-01

    A computerized platform has been developed to enhance behavioral testing during intraoperative language mapping in awake craniotomy procedures. The system is uniquely compatible with the environmental demands of both the operating room and preoperative functional MRI (fMRI), thus providing standardized testing toward improving spatial agreement between the 2 brain mapping techniques. Details of the platform architecture, its advantages over traditional testing methods, and its use for language mapping are described. Four illustrative cases demonstrate the efficacy of using the testing platform to administer sophisticated language paradigms, and the spatial agreement between intraoperative mapping and preoperative fMRI results. The testing platform substantially improved the ability of the surgeon to detect and characterize language deficits. Use of a written word generation task to assess language production helped confirm areas of speech apraxia and speech arrest that were inadequately characterized or missed with the use of traditional paradigms, respectively. Preoperative fMRI of the analogous writing task was also assistive, displaying excellent spatial agreement with intraoperative mapping in all 4 cases. Sole use of traditional testing paradigms can be limiting during awake craniotomy procedures. Comprehensive assessment of language function will require additional use of more sophisticated and ecologically valid testing paradigms. The platform presented here provides a means to do so.

  7. 14 CFR 21.129 - Tests: propellers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Tests: propellers. 21.129 Section 21.129... PROCEDURES FOR PRODUCTS AND PARTS Production Under Type Certificate § 21.129 Tests: propellers. Each person... functional test to determine if it operates properly throughout the normal range of operation. ...

  8. 14 CFR 21.129 - Tests: propellers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Tests: propellers. 21.129 Section 21.129... PROCEDURES FOR PRODUCTS AND PARTS Production Under Type Certificate § 21.129 Tests: propellers. Each person... functional test to determine if it operates properly throughout the normal range of operation. ...

  9. 21 CFR 809.10 - Labeling for in vitro diagnostic products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... principles of the procedure. Explain concisely, with chemical reactions and techniques involved, if...) Instruments: (i) Use or function. (ii) Installation procedures and special requirements. (iii) Principles of... product testing prior to full commercial marketing (for example, for use on specimens derived from humans...

  10. Validation of the MEPDG transfer functions using the LTPP test sections in Georgia task 2 interim report.

    DOT National Transportation Integrated Search

    2013-07-16

    The Georgia Department of Transportation (GDOT) is transitioning from empirical design procedures to the MEPDG : procedure for designing new and rehabilitated highway pavements. GDOT currently uses the 1972 AASHTO Interim : Guide for Design of Paveme...

  11. Innovative Use of Thighplasty to Improve Prosthesis Fit and Function in a Transfemoral Amputee.

    PubMed

    Kuiken, Todd A; Fey, Nicholas P; Reissman, Timothy; Finucane, Suzanne B; Dumanian, Gregory A

    2018-01-01

    Excess residual limb fat is a common problem that can impair prosthesis control and negatively impact gait. In the general population, thighplasty and liposuction are commonly performed for cosmetic reasons but not specifically to improve function in amputees. The objective of this study was to determine if these procedures could enhance prosthesis fit and function in an overweight above-knee amputee. We evaluated the use of these techniques on a 50-year-old transfemoral amputee who was overweight. The patient underwent presurgical imaging and tests to measure her residual limb tissue distribution, socket-limb interface stiffness, residual femur orientation, lower-extremity function, and prosthesis satisfaction. A medial thighplasty procedure with circumferential liposuction was performed, during which 2,812 g (6.2 lbs.) of subcutaneous fat and skin was removed from her residual limb. Imaging was repeated 5 months postsurgery; functional assessments were repeated 9 months postsurgery. The patient demonstrated notable improvements in socket fit and in performing most functional and walking tests. Her comfortable walking speed increased 13.3%, and her scores for the Sit-to-Stand and Four Square Step tests improved over 20%. Femur alignment in her socket changed from 8.13 to 4.14 degrees, and analysis showed a marked increase in the socket-limb interface stiffness. This study demonstrates the potential of using a routine plastic surgery procedure to modify the intrinsic properties of the limb and to improve functional outcomes in overweight or obese transfemoral amputees. This technique is a potentially attractive option compared with multiple reiterations of sockets, which can be time-consuming and costly.

  12. Least-squares/parabolized Navier-Stokes procedure for optimizing hypersonic wind tunnel nozzles

    NASA Technical Reports Server (NTRS)

    Korte, John J.; Kumar, Ajay; Singh, D. J.; Grossman, B.

    1991-01-01

    A new procedure is demonstrated for optimizing hypersonic wind-tunnel-nozzle contours. The procedure couples a CFD computer code to an optimization algorithm, and is applied to both conical and contoured hypersonic nozzles for the purpose of determining an optimal set of parameters to describe the surface geometry. A design-objective function is specified based on the deviation from the desired test-section flow-field conditions. The objective function is minimized by optimizing the parameters used to describe the nozzle contour based on the solution to a nonlinear least-squares problem. The effect of the changes in the nozzle wall parameters are evaluated by computing the nozzle flow using the parabolized Navier-Stokes equations. The advantage of the new procedure is that it directly takes into account the displacement effect of the boundary layer on the wall contour. The new procedure provides a method for optimizing hypersonic nozzles of high Mach numbers which have been designed by classical procedures, but are shown to produce poor flow quality due to the large boundary layers present in the test section. The procedure is demonstrated by finding the optimum design parameters for a Mach 10 conical nozzle and a Mach 6 and a Mach 15 contoured nozzle.

  13. Assessment of Differential Item Functioning in Testlet-Based Items Using the Rasch Testlet Model

    ERIC Educational Resources Information Center

    Wang, Wen-Chung; Wilson, Mark

    2005-01-01

    This study presents a procedure for detecting differential item functioning (DIF) for dichotomous and polytomous items in testlet-based tests, whereby DIF is taken into account by adding DIF parameters into the Rasch testlet model. Simulations were conducted to assess recovery of the DIF and other parameters. Two independent variables, test type…

  14. Using Differential Item Functioning Procedures to Explore Sources of Item Difficulty and Group Performance Characteristics.

    ERIC Educational Resources Information Center

    Scheuneman, Janice Dowd; Gerritz, Kalle

    1990-01-01

    Differential item functioning (DIF) methodology for revealing sources of item difficulty and performance characteristics of different groups was explored. A total of 150 Scholastic Aptitude Test items and 132 Graduate Record Examination general test items were analyzed. DIF was evaluated for males and females and Blacks and Whites. (SLD)

  15. A Review of ETS Differential Item Functioning Assessment Procedures: Flagging Rules, Minimum Sample Size Requirements, and Criterion Refinement. Research Report. ETS RR-12-08

    ERIC Educational Resources Information Center

    Zwick, Rebecca

    2012-01-01

    Differential item functioning (DIF) analysis is a key component in the evaluation of the fairness and validity of educational tests. The goal of this project was to review the status of ETS DIF analysis procedures, focusing on three aspects: (a) the nature and stringency of the statistical rules used to flag items, (b) the minimum sample size…

  16. 14 CFR 21.129 - Tests: propellers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Tests: propellers. 21.129 Section 21.129... PROCEDURES FOR PRODUCTS AND PARTS Production Under Type Certificate Only § 21.129 Tests: propellers. Each... acceptable functional test to determine if it operates properly throughout the normal range of operation. ...

  17. Performance of Density Functional Theory Procedures for the Calculation of Proton-Exchange Barriers: Unusual Behavior of M06-Type Functionals.

    PubMed

    Chan, Bun; Gilbert, Andrew T B; Gill, Peter M W; Radom, Leo

    2014-09-09

    We have examined the performance of a variety of density functional theory procedures for the calculation of complexation energies and proton-exchange barriers, with a focus on the Minnesota-class of functionals that are generally highly robust and generally show good accuracy. A curious observation is that M05-type and M06-type methods show an atypical decrease in calculated barriers with increasing proportion of Hartree-Fock exchange. To obtain a clearer picture of the performance of the underlying components of M05-type and M06-type functionals, we have investigated the combination of MPW-type and PBE-type exchange and B95-type and PBE-type correlation procedures. We find that, for the extensive E3 test set, the general performance of the various hybrid-DFT procedures improves in the following order: PBE1-B95 → PBE1-PBE → MPW1-PBE → PW6-B95. As M05-type and M06-type procedures are related to PBE1-B95, it would be of interest to formulate and examine the general performance of an alternative Minnesota DFT method related to PW6-B95.

  18. Lageos assembly operation plan

    NASA Technical Reports Server (NTRS)

    Brueger, J.

    1975-01-01

    Guidelines and constraints procedures for LAGEOS assembly, operation, and design performance are given. Special attention was given to thermal, optical, and dynamic analysis and testing. The operation procedures illustrate the interrelation and sequence of tasks in a flow diagram. The diagram also includes quality assurance functions for verification of operation tasks.

  19. Perspectives on the Pure-Tone Audiogram.

    PubMed

    Musiek, Frank E; Shinn, Jennifer; Chermak, Gail D; Bamiou, Doris-Eva

    The pure-tone audiogram, though fundamental to audiology, presents limitations, especially in the case of central auditory involvement. Advances in auditory neuroscience underscore the considerably larger role of the central auditory nervous system (CANS) in hearing and related disorders. Given the availability of behavioral audiological tests and electrophysiological procedures that can provide better insights as to the function of the various components of the auditory system, this perspective piece reviews the limitations of the pure-tone audiogram and notes some of the advantages of other tests and procedures used in tandem with the pure-tone threshold measurement. To review and synthesize the literature regarding the utility and limitations of the pure-tone audiogram in determining dysfunction of peripheral sensory and neural systems, as well as the CANS, and to identify other tests and procedures that can supplement pure-tone thresholds and provide enhanced diagnostic insight, especially regarding problems of the central auditory system. A systematic review and synthesis of the literature. The authors independently searched and reviewed literature (journal articles, book chapters) pertaining to the limitations of the pure-tone audiogram. The pure-tone audiogram provides information as to hearing sensitivity across a selected frequency range. Normal or near-normal pure-tone thresholds sometimes are observed despite cochlear damage. There are a surprising number of patients with acoustic neuromas who have essentially normal pure-tone thresholds. In cases of central deafness, depressed pure-tone thresholds may not accurately reflect the status of the peripheral auditory system. Listening difficulties are seen in the presence of normal pure-tone thresholds. Suprathreshold procedures and a variety of other tests can provide information regarding other and often more central functions of the auditory system. The audiogram is a primary tool for determining type, degree, and configuration of hearing loss; however, it provides the clinician with information regarding only hearing sensitivity, and no information about central auditory processing or the auditory processing of real-world signals (i.e., speech, music). The pure-tone audiogram offers limited insight into functional hearing and should be viewed only as a test of hearing sensitivity. Given the limitations of the pure-tone audiogram, a brief overview is provided of available behavioral tests and electrophysiological procedures that are sensitive to the function and integrity of the central auditory system, which provide better diagnostic and rehabilitative information to the clinician and patient. American Academy of Audiology

  20. Use of GDNF-Releasing Nanofiber Nerve Guide Conduits for the Repair of Conus Medullaris/Cauda Equina Injury in the Non-Human Primate

    DTIC Science & Technology

    2013-10-01

    functional assessments using locomotor testing, urodynamic recordings, electromyography of the pelvic floor , and pain behavioral testing. At 18...selection, trained staff to perform the behavioral screening and evaluation, as well as successfully implementing our procedures for animal enrollment and...to the start of surgical procedures, each enrolled rhesus macaque underwent extensive screening and training . Behavioral records and profiles were

  1. Which routine test for kidney function?

    PubMed Central

    Parkin, A; Smith, H C; Brocklebank, J T

    1989-01-01

    Eighty measurements of plasma creatinine concentration, height:creatinine ratio, and plasma beta 2 microglobulin concentration were made on 72 children (age 4 months-18.5 years) with known renal disease. Results were compared with simultaneous measurements of glomerular filtration rate using plasma clearance of 51Cr edetic acid to assess the performance of each test as an initial screening procedure of renal insufficiency. Height:creatinine index less than 2.1 was found to have a higher sensitivity and predictive value of a normal result than the other tests and is therefore the preferred test for a screening procedure. PMID:2510609

  2. ROC and Loss Function Analysis in Sequential Testing

    ERIC Educational Resources Information Center

    Muijtjens, Arno M. M.; Van Luijk, Scheltus J.; Van Der Vleuten, Cees P. M.

    2006-01-01

    Sequential testing is applied to reduce costs in SP-based tests (OSCEs). Initially, all candidates take a screening test consisting of a part of the OSCE. Candidates who fail the screen sit the complete test, whereas those who pass the screen are qualified as a pass of the complete test. The procedure may result in a reduction of testing…

  3. Steepest descent method implementation on unconstrained optimization problem using C++ program

    NASA Astrophysics Data System (ADS)

    Napitupulu, H.; Sukono; Mohd, I. Bin; Hidayat, Y.; Supian, S.

    2018-03-01

    Steepest Descent is known as the simplest gradient method. Recently, many researches are done to obtain the appropriate step size in order to reduce the objective function value progressively. In this paper, the properties of steepest descent method from literatures are reviewed together with advantages and disadvantages of each step size procedure. The development of steepest descent method due to its step size procedure is discussed. In order to test the performance of each step size, we run a steepest descent procedure in C++ program. We implemented it to unconstrained optimization test problem with two variables, then we compare the numerical results of each step size procedure. Based on the numerical experiment, we conclude the general computational features and weaknesses of each procedure in each case of problem.

  4. The Mark 3 Haploscope

    NASA Technical Reports Server (NTRS)

    Decker, T. A.; Williams, R. E.; Kuether, C. L.; Logar, N. D.; Wyman-Cornsweet, D.

    1975-01-01

    A computer-operated binocular vision testing device was developed as one part of a system designed for NASA to evaluate the visual function of astronauts during spaceflight. This particular device, called the Mark 3 Haploscope, employs semi-automated psychophysical test procedures to measure visual acuity, stereopsis, phoria, fixation disparity, refractive state and accommodation/convergence relationships. Test procedures are self-administered and can be used repeatedly without subject memorization. The Haploscope was designed as one module of the complete NASA Vision Testing System. However, it is capable of stand-alone operation. Moreover, the compactness and portability of the Haploscope make possible its use in a broad variety of testing environments.

  5. Liver Function Tests Following Irreversible Electroporation of Liver Tumors: Experience in 174 Procedures.

    PubMed

    Froud, Tatiana; Venkat, Shree R; Barbery, Katuzka J; Gunjan, Arora; Narayanan, Govindarajan

    2015-09-01

    Irreversible electroporation (IRE) is a relatively new ablation modality that uses electric currents to cause cell death. It is commonly used to treat primary and secondary liver tumors in patients with normal liver function and preexisting cirrhosis. Retrospective analysis of 205 procedures sought to evaluate changes in liver function after IRE. Liver function tests (LFTs) results before and after IRE were evaluated from 174 procedures in 124 patients. Aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase (ALKP), and total bilirubin levels were analyzed. The study was Health Insurance Portability and Accountability Act compliant and institutional review board approved. Informed consent was waived. Changes in LFT results after IRE were compared with baseline and were followed up over time to see if they resolved. Changes were compared with volume of ablation. The greatest perturbations were in transaminase levels. The levels increased sharply within 24 hours after IRE in 129 (74.1%) procedures to extreme levels (more than 20 times the upper limit of normal in one-third of cases). Resolution occurred in 95% and was demonstrated to have occurred by a mean of approximately 10 weeks, many documented as early as 7 days after procedure. ALKP levels elevated in 10% procedures, was slower to increase, and was less likely to resolve. Total bilirubin level demonstrated 2 different patterns of elevation--early and late--and similar to ALKP, it was more likely to remain elevated. There was no increased risk in patients with cirrhosis or cholangiocarcinoma. There was no correlation of levels with volume of ablation. IRE results in significant abnormalities in LFT results, but in most of the cases, these are self-limiting, do not preclude treatment, and are similar to the changes seen after radiofrequency and cryoablation in the liver. Copyright © 2015. Published by Elsevier Inc.

  6. Validated Test Method 1316: Liquid-Solid Partitioning as a Function of Liquid-to-Solid Ratio in Solid Materials Using a Parallel Batch Procedure

    EPA Pesticide Factsheets

    Describes procedures written based on the assumption that they will be performed by analysts who are formally trained in at least the basic principles of chemical analysis and in the use of the subject technology.

  7. Proof of concept test plan.

    DOT National Transportation Integrated Search

    2008-06-05

    This document is the Proof of Concept (POC) Test Plan and procedures that will be used : to verify that hardware and application functionality meet the requirements of the U.S. : Department of Transportation (USDOT) Next Generation 9-1-1 Initiative (...

  8. Experimental determination of the particle motions associated with the low order acoustic modes in enclosures

    NASA Technical Reports Server (NTRS)

    Byrne, K. P.; Marshall, S. E.

    1983-01-01

    A procedure for experimentally determining, in terms of the particle motions, the shapes of the low order acoustic modes in enclosures is described. The procedure is based on finding differentiable functions which approximate the shape functions of the low order acoustic modes when these modes are defined in terms of the acoustic pressure. The differentiable approximating functions are formed from polynomials which are fitted by a least squares procedure to experimentally determined values which define the shapes of the low order acoustic modes in terms of the acoustic pressure. These experimentally determined values are found by a conventional technique in which the transfer functions, which relate the acoustic pressures at an array of points in the enclosure to the volume velocity of a fixed point source, are measured. The gradient of the function which approximates the shape of a particular mode in terms of the acoustic pressure is evaluated to give the mode shape in terms of the particle motion. The procedure was tested by using it to experimentally determine the shapes of the low order acoustic modes in a small rectangular enclosure.

  9. Payload and Components Real-Time Automated Test System (PACRATS), Data Acquisition of Leak Rate and Pressure Data Test Procedure

    NASA Technical Reports Server (NTRS)

    Rinehart, Maegan L.

    2011-01-01

    The purpose of this activity is to provide the Mechanical Components Test Facility (MCTF) with the capability to obtain electronic leak test and proof pressure data, Payload and Components Real-time Automated Test System (PACRATS) data acquisition software will be utilized to display real-time data. It will record leak rates and pressure/vacuum level(s) simultaneously. This added functionality will provide electronic leak test and pressure data at specified sampling frequencies. Electronically stored data will provide ES61 with increased data security, analysis, and accuracy. The tasks performed in this procedure are to verify PACRATS only, and are not intended to provide verifications for MCTF equipment.

  10. Functional Analysis and Treatment of Multiply Controlled Inappropriate Mealtime Behavior

    ERIC Educational Resources Information Center

    Bachmeyer, Melanie H.; Piazza, Cathleen C.; Fredrick, Laura D.; Reed, Gregory K.; Rivas, Kristi D.; Kadey, Heather J.

    2009-01-01

    Functional analyses identified children whose inappropriate mealtime behavior was maintained by escape and adult attention. Function-based extinction procedures were tested individually and in combination. Attention extinction alone did not result in decreases in inappropriate mealtime behavior or a significant increase in acceptance. By contrast,…

  11. On one-sided filters for spectral Fourier approximations of discontinuous functions

    NASA Technical Reports Server (NTRS)

    Wei, Cai; Gottlieb, David; Shu, Chi-Wang

    1991-01-01

    The existence of one-sided filters, for spectral Fourier approximations of discontinuous functions, which can recover spectral accuracy up to discontinuity from one side, was proved. A least square procedure was also used to construct such a filter and test it on several discontinuous functions numerically.

  12. Significance tests for functional data with complex dependence structure.

    PubMed

    Staicu, Ana-Maria; Lahiri, Soumen N; Carroll, Raymond J

    2015-01-01

    We propose an L 2 -norm based global testing procedure for the null hypothesis that multiple group mean functions are equal, for functional data with complex dependence structure. Specifically, we consider the setting of functional data with a multilevel structure of the form groups-clusters or subjects-units, where the unit-level profiles are spatially correlated within the cluster, and the cluster-level data are independent. Orthogonal series expansions are used to approximate the group mean functions and the test statistic is estimated using the basis coefficients. The asymptotic null distribution of the test statistic is developed, under mild regularity conditions. To our knowledge this is the first work that studies hypothesis testing, when data have such complex multilevel functional and spatial structure. Two small-sample alternatives, including a novel block bootstrap for functional data, are proposed, and their performance is examined in simulation studies. The paper concludes with an illustration of a motivating experiment.

  13. Ethanol-reinforced responding by AA and ANA rats following the sucrose-substitution initiation procedure.

    PubMed

    Files, F J; Denning, C E; Hyytia, P; Kiianmaa, K; Samson, H H

    1997-06-01

    Ethanol-reinforced responding was initiated in male AA and ANA rats using the sucrose-substitution procedure. Before the initiation procedure, a homecage, two-bottle preference test was conducted. The rats were then trained to respond on an Fixed-Ratio 1 schedule with sucrose reinforcement. Over sessions, ethanol was added gradually to the sucrose solution as the concentration of sucrose was reduced until 10% ethanol (v/v) alone functioned as the reinforcer for lever pressing. The schedule of reinforcement was then increased to Fixed-Ratio 4. Next, the ethanol concentration presented as the reinforcer was increased over weeks to 15%, 20%, 30%, and then returned to 10%. A second homecage test was then performed. The results showed that the AA and ANA lines differed significantly on preference and intake (g/kg) during the homecage preference tests. There was a significant increase in preference during the second homecage test. During sucrose substitution, initial large differences in responding were observed between the lines. When the ethanol concentration was increased, intake (grams per kilogram) increased for the AA line but not for the ANA line. These effects were a function of no change in responding by the AA rats as concentration was increased and a decrease in responding by the ANA rats at the higher concentrations (20% and 30%). Taken together, data indicate that ethanol can function as a positive reinforcer for the behavior of AA and ANA rats. Even though 10% ethanol functioned as a reinforcer similarly for the two lines, ethanol intake in the AA line was significantly greater at the higher concentrations of ethanol, suggesting that ethanol functioned as a qualitatively different reinforcer for the AA rats, compared with the ANA rats.

  14. Controlling Type I Error Rates in Assessing DIF for Logistic Regression Method Combined with SIBTEST Regression Correction Procedure and DIF-Free-Then-DIF Strategy

    ERIC Educational Resources Information Center

    Shih, Ching-Lin; Liu, Tien-Hsiang; Wang, Wen-Chung

    2014-01-01

    The simultaneous item bias test (SIBTEST) method regression procedure and the differential item functioning (DIF)-free-then-DIF strategy are applied to the logistic regression (LR) method simultaneously in this study. These procedures are used to adjust the effects of matching true score on observed score and to better control the Type I error…

  15. 40 CFR 53.62 - Test procedure: Full wind tunnel test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... accuracy of 5 percent or better (e.g., hot-wire anemometry). For the wind speeds specified in table F-2 of... candidate sampler as a function of aerodynamic particle diameter (Dae) on semi-logarithmic graph paper where...

  16. 40 CFR 53.62 - Test procedure: Full wind tunnel test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... accuracy of 5 percent or better (e.g., hot-wire anemometry). For the wind speeds specified in table F-2 of... candidate sampler as a function of aerodynamic particle diameter (Dae) on semi-logarithmic graph paper where...

  17. 40 CFR 53.62 - Test procedure: Full wind tunnel test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... accuracy of 5 percent or better (e.g., hot-wire anemometry). For the wind speeds specified in table F-2 of... candidate sampler as a function of aerodynamic particle diameter (Dae) on semi-logarithmic graph paper where...

  18. 40 CFR 53.62 - Test procedure: Full wind tunnel test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... accuracy of 5 percent or better (e.g., hot-wire anemometry). For the wind speeds specified in table F-2 of... candidate sampler as a function of aerodynamic particle diameter (Dae) on semi-logarithmic graph paper where...

  19. Comparison on testability of visual acuity, stereo acuity and colour vision tests between children with learning disabilities and children without learning disabilities in government primary schools.

    PubMed

    Abu Bakar, Nurul Farhana; Chen, Ai-Hong

    2014-02-01

    Children with learning disabilities might have difficulties to communicate effectively and give reliable responses as required in various visual function testing procedures. The purpose of this study was to compare the testability of visual acuity using the modified Early Treatment Diabetic Retinopathy Study (ETDRS) and Cambridge Crowding Cards, stereo acuity using Lang Stereo test II and Butterfly stereo tests and colour perception using Colour Vision Test Made Easy (CVTME) and Ishihara's Test for Colour Deficiency (Ishihara Test) between children in mainstream classes and children with learning disabilities in special education classes in government primary schools. A total of 100 primary school children (50 children from mainstream classes and 50 children from special education classes) matched in age were recruited in this cross-sectional comparative study. The testability was determined by the percentage of children who were able to give reliable respond as required by the respective tests. 'Unable to test' was defined as inappropriate response or uncooperative despite best efforts of the screener. The testability of the modified ETDRS, Butterfly stereo test and Ishihara test for respective visual function tests were found lower among children in special education classes ( P < 0.001) but not in Cambridge Crowding Cards, Lang Stereo test II and CVTME. Non verbal or "matching" approaches were found to be more superior in testing visual functions in children with learning disabilities. Modifications of vision testing procedures are essential for children with learning disabilities.

  20. Image-guided intervention in the coagulopathic patient.

    PubMed

    Kohli, Marc; Mayo-Smith, William; Zagoria, Ronald; Sandrasegaran, Kumar

    2016-04-01

    Determining practice parameters for interventional procedures is challenging due to many factors including unreliable laboratory tests to measure bleeding risk, variable usage of standardized terminology for adverse events, poorly defined standards for administration of blood products, and the growing numbers of anticoagulant and antiplatelet medications. We aim to address these and other issues faced by radiologists performing invasive procedures through a review of available literature, and experiential guidance from three academic medical centers. We discuss the significant limitations with respect to using prothrombin-time and international normalized ratio to measure bleeding risk, especially in patients with synthetic defects due to liver function. Factors affecting platelet function including the impact of uremia; recent advances in laboratory testing, including platelet function testing; and thromboelastography are also discussed. A review of the existing literature of fresh-frozen plasma replacement therapy is included. The literature regarding comorbidities affecting coagulation including malignancy, liver failure, and uremia are also reviewed. Finally, the authors present a set of recommendations for laboratory thresholds, corrective transfusions, as well as withholding and restarting medications.

  1. 10 CFR 50.59 - Changes, tests, and experiments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Changes, tests, and experiments. 50.59 Section 50.59..., Limitations, and Conditions of Licenses and Construction Permits § 50.59 Changes, tests, and experiments. (a..., the facility or procedures that affects a design function, method of performing or controlling the...

  2. 10 CFR 50.59 - Changes, tests, and experiments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Changes, tests, and experiments. 50.59 Section 50.59..., Limitations, and Conditions of Licenses and Construction Permits § 50.59 Changes, tests, and experiments. (a..., the facility or procedures that affects a design function, method of performing or controlling the...

  3. Psychophysical contrast calibration

    PubMed Central

    To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli

    2013-01-01

    Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843

  4. Chemical, Biological, and Radiological Contamination Survivability: Material Effects Testing

    DTIC Science & Technology

    2012-06-22

    form that can be compared to pretest and posttest functional performance data. If Soldiers are desired, ensure a Test Schedule and Review Committee...test execution. f. The material’s performance specification should also be reviewed before planning test execution. For example , the...test data, and conformance with specified test and operating procedures cannot be overemphasized. 3.1 Test Planning. 3.1.1 Pretest Preparation

  5. Functional Testing Communication Equipment (Avionics).

    DTIC Science & Technology

    1980-07-31

    Yes No . Comment : 2. Were the facilities, test equipment, instrumentation, and support accommodations adequate to accomplish the test objectives...Yes No . Comment : 3. Have all data collected been reviewed for correctness and completeness? Yes No . Comment : 4. Were the test results compromised in...any way due to insufficient test planning? Yes No . Comment : 5. Were the test results compromised in any way due to test performance procedures? Yes No

  6. Surveillance system and method having an adaptive sequential probability fault detection test

    NASA Technical Reports Server (NTRS)

    Herzog, James P. (Inventor); Bickford, Randall L. (Inventor)

    2005-01-01

    System and method providing surveillance of an asset such as a process and/or apparatus by providing training and surveillance procedures that numerically fit a probability density function to an observed residual error signal distribution that is correlative to normal asset operation and then utilizes the fitted probability density function in a dynamic statistical hypothesis test for providing improved asset surveillance.

  7. Surveillance system and method having an adaptive sequential probability fault detection test

    NASA Technical Reports Server (NTRS)

    Bickford, Randall L. (Inventor); Herzog, James P. (Inventor)

    2006-01-01

    System and method providing surveillance of an asset such as a process and/or apparatus by providing training and surveillance procedures that numerically fit a probability density function to an observed residual error signal distribution that is correlative to normal asset operation and then utilizes the fitted probability density function in a dynamic statistical hypothesis test for providing improved asset surveillance.

  8. Surveillance System and Method having an Adaptive Sequential Probability Fault Detection Test

    NASA Technical Reports Server (NTRS)

    Bickford, Randall L. (Inventor); Herzog, James P. (Inventor)

    2008-01-01

    System and method providing surveillance of an asset such as a process and/or apparatus by providing training and surveillance procedures that numerically fit a probability density function to an observed residual error signal distribution that is correlative to normal asset operation and then utilizes the fitted probability density function in a dynamic statistical hypothesis test for providing improved asset surveillance.

  9. Validated Test Method 1314: Liquid-Solid Partitioning as a Function of Liquid-Solid Ratio for Constituents in Solid Materials Using An Up-Flow Percolation Column Procedure

    EPA Pesticide Factsheets

    Describes procedures written based on the assumption that they will be performed by analysts who are formally trained in at least the basic principles of chemical analysis and in the use of the subject technology.

  10. The gradational step test for assessing cardiorespiratory capacity : an experimental evaluation of treadmill and step test procedures.

    DOT National Transportation Integrated Search

    1964-01-01

    "Physical fitness" - the potential capacity for making adequate functional adjustments to increased metabolic demands - is most meaningful and accurately assessed in the laboratory by making physiological measurements on the experimental subject whil...

  11. Decisions that Make a Difference in Detecting Differential Item Functioning

    ERIC Educational Resources Information Center

    Sireci, Stephen G.; Rios, Joseph A.

    2013-01-01

    There are numerous statistical procedures for detecting items that function differently across subgroups of examinees that take a test or survey. However, in endeavouring to detect items that may function differentially, selection of the statistical method is only one of many important decisions. In this article, we discuss the important decisions…

  12. EMC system test performance on Spacelab

    NASA Astrophysics Data System (ADS)

    Schwan, F.

    1982-07-01

    Electromagnetic compatibility testing of the Spacelab engineering model is discussed. Documentation, test procedures (including data monitoring and test configuration set up) and performance assessment approach are described. Equipment was assembled into selected representative flight configurations. The physical and functional interfaces between the subsystems were demonstrated within the integration and test sequence which culminated in the flyable configuration Long Module plus one Pallet.

  13. A Statistical Analysis of Brain Morphology Using Wild Bootstrapping

    PubMed Central

    Ibrahim, Joseph G.; Tang, Niansheng; Rowe, Daniel B.; Hao, Xuejun; Bansal, Ravi; Peterson, Bradley S.

    2008-01-01

    Methods for the analysis of brain morphology, including voxel-based morphology and surface-based morphometries, have been used to detect associations between brain structure and covariates of interest, such as diagnosis, severity of disease, age, IQ, and genotype. The statistical analysis of morphometric measures usually involves two statistical procedures: 1) invoking a statistical model at each voxel (or point) on the surface of the brain or brain subregion, followed by mapping test statistics (e.g., t test) or their associated p values at each of those voxels; 2) correction for the multiple statistical tests conducted across all voxels on the surface of the brain region under investigation. We propose the use of new statistical methods for each of these procedures. We first use a heteroscedastic linear model to test the associations between the morphological measures at each voxel on the surface of the specified subregion (e.g., cortical or subcortical surfaces) and the covariates of interest. Moreover, we develop a robust test procedure that is based on a resampling method, called wild bootstrapping. This procedure assesses the statistical significance of the associations between a measure of given brain structure and the covariates of interest. The value of this robust test procedure lies in its computationally simplicity and in its applicability to a wide range of imaging data, including data from both anatomical and functional magnetic resonance imaging (fMRI). Simulation studies demonstrate that this robust test procedure can accurately control the family-wise error rate. We demonstrate the application of this robust test procedure to the detection of statistically significant differences in the morphology of the hippocampus over time across gender groups in a large sample of healthy subjects. PMID:17649909

  14. Sexual function in women following transvaginal mesh procedures for the treatment of pelvic organ prolapse.

    PubMed

    Liang, Ching-Chung; Lo, Tsia-Shu; Tseng, Ling-Hong; Lin, Yi-Hao; Lin, Yu-Jr; Chang, Shuenn-Dhy

    2012-10-01

    Synthetic mesh kits recently adopted in pelvic reconstructive surgeries have achieved great surgical efficacy, but the effects of transvaginal synthetic mesh procedures on women's sexual function are still controversial. This study was conducted to demonstrate sexual function in women before and after surgery with transvaginal mesh (TVM) repair for pelvic organ prolapse (POP). A total of 93 sexually active women scheduled for correcting POP with synthetic mesh kits were recruited. In addition to urogynecological history, pelvic examination by the Pelvic Organ Prolapse Quantification system, and urodynamic testing, consenting participants were asked to complete the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12) to evaluate sexual function before and after surgery. At the 3-month urodynamic studies, among the 25 patients with coexistent urodynamic stress incontinence (USI) who had undergone a concomitant transobturator suburethral tape procedure (TOT), 1 (4 %) had persistent USI; 8 of 68 (11.8 %) patients with a negative pessary test developed postoperative USI. Six-month prolapse recurrence rates following TVM alone and TVM with concomitant TOT were 9 and 12 %, respectively. The total PISQ-12 score after surgery showed worse results in the TVM alone group but not in the TVM with concomitant TOT group. The individual scores of PISQ-12 after surgery demonstrated prolapse-related items improved in both TVM groups; sexual function worsened in dyspareunia and behavior domains. Our data revealed that transvaginal synthetic mesh procedures for the treatment of POP generated favorable clinical outcomes, but situations might worsen in dyspareunia and behavior domains, thereby invoking a negative emotional reaction during intercourse after surgery.

  15. Effect of Septorhinoplasty on Olfactory Function: Assessment Using the Brief Smell Identification Test.

    PubMed

    Dengiz, Ramazan; Haytoğlu, Süheyl; Görgülü, Orhan; Doğru, Mehmet; Arıkan, Osman Kürşat

    2015-03-01

    Septorhinoplasty (SRP), one of the most commonly performed rhinologic surgery procedures, can affect olfactory function; however, the findings of studies investigating smell following SRP are controversial. We used a culturally adapted modified Brief Smell Identification Test (B-SIT) to investigate the long- and short-term effects of SRP on olfactory function. We enrolled 59 patients admitted to the Ear-Nose-Throat Clinic, who were complaining of external nasal deformity and nasal obstruction. Functional SRP was performed on all cases. The B-SIT was administered prior to surgery and at 4 and 12 weeks post-surgery. The smell identification score (SIS) reflected the number of correct answers. In addition, we investigated the effects of gender and smoking on olfactory function and whether the SRP procedure changed these associations. The mean preoperative, 4-week, and 12-week postoperative SISs were 10.15±1.30, 10.21±1.52, and 10.92±0.95, respectively. The difference between the preoperative and 4-week postoperative SISs was not statistically significant; however, the 12-week postoperative score was significantly different from the preoperative and 4-week postoperative scores. Furthermore, the repeated measures analysis according to gender and smoking habit revealed a significant difference between the 4-and 12-week postoperative SISs. One patient developed postoperative anosmia; however, the patient recovered in the 12-week postoperative period. SRP surgery is a safe procedure in terms of olfactory function. In addition, olfactory function may increase following surgery as a result of improved nasal airflow.

  16. Representation of the Physiological Factors Contributing to Postflight Changes in Functional Performance Using Motion Analysis Software

    NASA Technical Reports Server (NTRS)

    Parks, Kelsey

    2010-01-01

    Astronauts experience changes in multiple physiological systems due to exposure to the microgravity conditions of space flight. To understand how changes in physiological function influence functional performance, a testing procedure has been developed that evaluates both astronaut postflight functional performance and related physiological changes. Astronauts complete seven functional and physiological tests. The objective of this project is to use motion tracking and digitizing software to visually display the postflight decrement in the functional performance of the astronauts. The motion analysis software will be used to digitize astronaut data videos into stick figure videos to represent the astronauts as they perform the Functional Tasks Tests. This project will benefit NASA by allowing NASA scientists to present data of their neurological studies without revealing the identities of the astronauts.

  17. Framework for adaptive multiscale analysis of nonhomogeneous point processes.

    PubMed

    Helgason, Hannes; Bartroff, Jay; Abry, Patrice

    2011-01-01

    We develop the methodology for hypothesis testing and model selection in nonhomogeneous Poisson processes, with an eye toward the application of modeling and variability detection in heart beat data. Modeling the process' non-constant rate function using templates of simple basis functions, we develop the generalized likelihood ratio statistic for a given template and a multiple testing scheme to model-select from a family of templates. A dynamic programming algorithm inspired by network flows is used to compute the maximum likelihood template in a multiscale manner. In a numerical example, the proposed procedure is nearly as powerful as the super-optimal procedures that know the true template size and true partition, respectively. Extensions to general history-dependent point processes is discussed.

  18. Determination of right ventricular ejection fraction in children with cystic fibrosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piepsz, A.; Ham, H.R.; Millet, E.

    1987-01-01

    The radionuclide right ventricular ejection fraction (RVEF) determined by means of Krypton-81m represents a simple, noninvasive, and accurate procedure to quantify the right ventricular contractility. This procedure was applied to 25 young patients with cystic fibrosis. The RVEF tended to decrease with the progression of the lung disease, as assessed by the clinical S-K score, the degree of the defects on lung scintigraphy, the PaO/sub 2/, and the lung function tests. However, the decrease of RVEF in patients with marked lung function tests. However, the decrease of RVEF in patients with marked lung involvement was moderate, and terminal lung diseasemore » was sometimes associated with normal right heart contractility.« less

  19. Analysis of Two Advanced Smoothing Algorithms.

    DTIC Science & Technology

    1985-09-01

    59 B. METHODOLOGY . ......... ........... 60 6 C. TESTING AND RESULTS ---- LINEAR UNDERLYING FUNCTION...SMOOTHING ALGORITHMS ...... .................... 94 A. GENERAL ......... ....................... .. 94 B. METHODOLOGY ............................ .95 C...to define succinctly. 59 B. METHODOLOGY There is no established procedure to follow in testing the efficiency and effectiveness of a smoothing

  20. Relationship between histopathological changes in post partum renal biopsies and renal function tests of African women with early onset pre-eclampsia.

    PubMed

    Khedun, S M; Naicker, T; Moodley, J

    2000-05-01

    To improve the diagnostic accuracy of concurrent renal disease in hypertension of pregnancy, biopsy evaluation is essential. In addition, establishing underlying renal disease is important for prognosis on future pregnancies. We therefore designed a study to determine the diagnostic yield of postpartum renal biopsy and the nature and frequency of complications associated with this procedure. Also, to determine relationships, if any, between renal function tests and ultrastructural and histopathological findings. Fifty renal biopsies were performed in the immediate postpartum period in black African women with early onset pre-eclampsia. Each biopsy specimen was placed in a separate container and coded so that sampling was unknown to the electron microscopist. Each biopsy specimen was divided into three parts, and processed and stained for light, fluorescent and transmission electron microscopy using conventional techniques. Renal tissue biopsies were adequate for diagnostic purposes in all cases. There were no complications in any of the 50 patients studied. Ultrastructural examination confirmed the light microscopy findings. In addition the ultrastructural findings showed intramembranous deposits, foot process fusion and mesangial deposits. In 16 patients with normal renal function tests; the biopsies evaluation from these patients showed ultrastructural changes. In the remaining 34 patients with abnormal renal function tests of varying severity; biopsy evaluation from these patients showed both ultrastructural and histopathological changes. Renal biopsy procedure is safe, and ultrastructural and histological findings obtained from postpartum renal biopsies are more informative than the routine renal function tests.

  1. A Note on Three Statistical Tests in the Logistic Regression DIF Procedure

    ERIC Educational Resources Information Center

    Paek, Insu

    2012-01-01

    Although logistic regression became one of the well-known methods in detecting differential item functioning (DIF), its three statistical tests, the Wald, likelihood ratio (LR), and score tests, which are readily available under the maximum likelihood, do not seem to be consistently distinguished in DIF literature. This paper provides a clarifying…

  2. An Extension of the Chi-Square Procedure for Non-NORMAL Statistics, with Application to Solar Neutrino Data

    NASA Astrophysics Data System (ADS)

    Sturrock, P. A.

    2008-01-01

    Using the chi-square statistic, one may conveniently test whether a series of measurements of a variable are consistent with a constant value. However, that test is predicated on the assumption that the appropriate probability distribution function (pdf) is normal in form. This requirement is usually not satisfied by experimental measurements of the solar neutrino flux. This article presents an extension of the chi-square procedure that is valid for any form of the pdf. This procedure is applied to the GALLEX-GNO dataset, and it is shown that the results are in good agreement with the results of Monte Carlo simulations. Whereas application of the standard chi-square test to symmetrized data yields evidence significant at the 1% level for variability of the solar neutrino flux, application of the extended chi-square test to the unsymmetrized data yields only weak evidence (significant at the 4% level) of variability.

  3. Procedural and declarative memory performance, and the memory consolidation function of sleep, in recent and abstinent Ecstasy/MDMA users

    PubMed Central

    Blagrove, Mark; Seddon, Jennifer; George, Sophie; Parrott, Andrew C.; Stickgold, Robert; Walker, Matthew; Jones, Katy; Morgan, Michael J.

    2013-01-01

    This study assessed the effects of ecstasy/MDMA on declarative memory (Rivermead Behavioral Memory task - RBMT), on procedural learning (Finger Tapping Task - FTT), and on the memory consolidation function of sleep for these two tasks. Testing occurred in 2 afternoon testing sessions, 24 hours apart so that a full period of sleep was allowed between them. Groups were: Non-drug taking Controls (n=24); Recent Ecstasy/MDMA users, who had taken ecstasy and/or MDMA 2–3 days before the first testing session (n=25), and Abstinent Ecstasy/MDMA users, who had not taken ecstasy/MDMA for at least 8 days before the first session (n=17). The recent ecstasy/MDMA users performed significantly worse than controls on the RBMT (mean recall 76.1% of control group recall), but did not differ from controls on FTT performance. Correspondingly there was a significant regression between the continuous variable of recency of ecstasy/MDMA use and RBMT performance. However, there was an interaction between ecstasy/MDMA use and subsequent other drug use. Controls had similar RBMT scores to recent ecstasy/MDMA users who did not take other drugs 48 – 24 hours before testing, but scored significantly better than recent ecstasy/MDMA users who took various other drugs (mainly cannabis) 48 – 24 hours before testing. For both tasks the control, recent ecstasy/MDMA and abstinent ecstasy/MDMA users did not differ in their change of performance across 24 hours; there was thus no evidence that ecstasy/MDMA impairs the memory consolidation function of sleep for either declarative or procedural memory. For participants in the two ecstasy/MDMA groups greater lifetime consumption of ecstasy tablets was associated with significantly more deficits in procedural memory. Furthermore, greater lifetime consumption of ecstasy tablets and of cocaine, were also associated with significantly more deficits in declarative memory. PMID:20615932

  4. Procedure for quantitative determination of effectiveness of photoinduced destruction of malignant tumors

    NASA Astrophysics Data System (ADS)

    Bizyuk, S. A.; Istomin, Yu. P.; Dzhagarov, B. M.

    2006-07-01

    We have developed a procedure for analysis of the functional status of blood vessels in tumor tissues using computer-assisted color scanning of tumor slices and also for a quantitative assessment of the effectiveness of photoinduced destruction of tumor tissues in animal experiments. Its major advantage is direct determination of the size of the tumor necrosis zone. The procedure has been tested in an experiment on three strains of malignant tumors with different morphologies.

  5. 34 CFR 462.11 - What must an application contain?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the methodology and procedures used to measure the reliability of the test. (h) Construct validity... previous test, and results from validity, reliability, and equating or standard-setting studies undertaken... NRS educational functioning levels (content validity). Documentation of the extent to which the items...

  6. Comparison on testability of visual acuity, stereo acuity and colour vision tests between children with learning disabilities and children without learning disabilities in government primary schools

    PubMed Central

    Abu Bakar, Nurul Farhana; Chen, Ai-Hong

    2014-01-01

    Context: Children with learning disabilities might have difficulties to communicate effectively and give reliable responses as required in various visual function testing procedures. Aims: The purpose of this study was to compare the testability of visual acuity using the modified Early Treatment Diabetic Retinopathy Study (ETDRS) and Cambridge Crowding Cards, stereo acuity using Lang Stereo test II and Butterfly stereo tests and colour perception using Colour Vision Test Made Easy (CVTME) and Ishihara's Test for Colour Deficiency (Ishihara Test) between children in mainstream classes and children with learning disabilities in special education classes in government primary schools. Materials and Methods: A total of 100 primary school children (50 children from mainstream classes and 50 children from special education classes) matched in age were recruited in this cross-sectional comparative study. The testability was determined by the percentage of children who were able to give reliable respond as required by the respective tests. ‘Unable to test’ was defined as inappropriate response or uncooperative despite best efforts of the screener. Results: The testability of the modified ETDRS, Butterfly stereo test and Ishihara test for respective visual function tests were found lower among children in special education classes (P < 0.001) but not in Cambridge Crowding Cards, Lang Stereo test II and CVTME. Conclusion: Non verbal or “matching” approaches were found to be more superior in testing visual functions in children with learning disabilities. Modifications of vision testing procedures are essential for children with learning disabilities. PMID:24008790

  7. Evaluation of Suited and Unsuited Human Functional Strength Using Multipurpose, Multiaxial Isokinetic Dynamometer

    NASA Technical Reports Server (NTRS)

    Aghazadeh, Fred

    2005-01-01

    The objective of the planned summer research was to develop a procedure to determine the isokinetic functional strength of suited and unsuited participants in order to estimate the coefficient of micro-gravity suit on human strength. To accomplish this objective, the Anthropometry and Biomechanics Facility's Multipurpose, Multiaxial Isokinetic dynamometer (MMID) was used. Development of procedure involved selection and testing of seven routines to be tested on MMID. We conducted the related experiments and collected the data for 12 participants. In addition to the above objective, we developed a procedure to assess the fatiguing characteristics of suited and unsuited participants using EMG technique. We collected EMG data on 10 participants while performing a programmed routing on MMID. EMG data along with information on the exerted forces, effector speed, number of repetitions, and duration of each routine were recorded for further analysis. Finally, gathering and tabulation Of data for various human strengths for updating of MSIS (HSIS) strength requirement, which started in summer 2003, also continued.

  8. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  9. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  10. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  11. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  12. 40 CFR 798.6050 - Functional observational battery.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... observational battery is a noninvasive procedure designed to detect gross functional deficits in young adults.... This battery of tests is not intended to provide a detailed evaluation of neurotoxicity. It is designed... such factors as the comparative metabolism of the chemical and species sensitivity to the toxic effects...

  13. [The structural functional analysis of functioning of day-hospitals of the Russian Federation].

    PubMed

    2012-01-01

    The article deals with the results of structural functional analysis of functioning of day-hospitals in the Russian Federation. The dynamic analysis is presented concerning day-hospitals' network, capacity; financial support, beds stock structure, treated patients structure, volumes of diagnostic tests and curative procedures. The need in developing of population medical care in conditions of day-hospitals is demonstrated.

  14. Recent lung imaging studies. [Effectiveness for diagnosis of chronic obstructive pulmonary disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taplin, G.V.; Chopra, S.K.

    1976-01-01

    Radionuclide lung imaging procedures have been available for 11 years but only the perfusion examination has been used extensively and mainly for the diagnosis of pulmonary embolism (P.E.). Its ability to reveal localized ischemia makes it a valuable test of regional lung function as well as a useful diagnostic aid in P.E. Although it had been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as amore » means of distinguishing P.E. from COPD. In this review emphasis is placed on our recent experience with both of these inhalation procedures in comparison with pulmonary function tests and roentgenography for the early detection of COPD in population studies. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imaging for a functional diagnosis of P.E. Two new developments in regional lung diffusion imaging, performed after the inhalation of radioactive gases and/or rapidly absorbed radioaerosols are described. The experimental basis for their potential clinical application in pulmonary embolism detection is presented.« less

  15. [Surgical treatment of normal pressure hydrocephalus].

    PubMed

    Svendsen, F; Hugdahl, K; Wester, K

    2001-05-30

    Normal pressure hydrocephalus (NPH) is an important diagnosis to keep in mind, i.e. the possibility that NPH and not a neurodegenerative disease causes the patient's symptoms with ataxia, urinary incontinence and dementia. Clinical improvement, sometimes a complete reversal of the symptoms, may be seen after a simple surgical procedure. This prospective study was performed by testing eight consecutively shunted patients with a walking test and a cognitive test battery pre- and postoperatively. Improvement 3-4 months after the shunting procedure suggests that NPH was present in six of eight patients. Walking ability was improved after surgery, also in patients with severe dementia. Severe dementia caused by NPH is hardly reversible, though cognitive tests may indicate some improvement. However, early surgical treatment of NPH in patients not suffering from a dementia according to the Mini Mental Status Test may bring improvement in some cognitive functions. Patients with both clinical and radiological signs of normal pressure hydrocephalus should be offered a shunting procedure.

  16. 14 CFR 120.203 - General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... applicable to employers by this subpart. (c) Employer responsibility. As an employer, you are responsible for... employees who perform safety-sensitive functions in aviation. (b) Alcohol testing procedures. Each employer...

  17. Models and analysis for multivariate failure time data

    NASA Astrophysics Data System (ADS)

    Shih, Joanna Huang

    The goal of this research is to develop and investigate models and analytic methods for multivariate failure time data. We compare models in terms of direct modeling of the margins, flexibility of dependency structure, local vs. global measures of association, and ease of implementation. In particular, we study copula models, and models produced by right neutral cumulative hazard functions and right neutral hazard functions. We examine the changes of association over time for families of bivariate distributions induced from these models by displaying their density contour plots, conditional density plots, correlation curves of Doksum et al, and local cross ratios of Oakes. We know that bivariate distributions with same margins might exhibit quite different dependency structures. In addition to modeling, we study estimation procedures. For copula models, we investigate three estimation procedures. the first procedure is full maximum likelihood. The second procedure is two-stage maximum likelihood. At stage 1, we estimate the parameters in the margins by maximizing the marginal likelihood. At stage 2, we estimate the dependency structure by fixing the margins at the estimated ones. The third procedure is two-stage partially parametric maximum likelihood. It is similar to the second procedure, but we estimate the margins by the Kaplan-Meier estimate. We derive asymptotic properties for these three estimation procedures and compare their efficiency by Monte-Carlo simulations and direct computations. For models produced by right neutral cumulative hazards and right neutral hazards, we derive the likelihood and investigate the properties of the maximum likelihood estimates. Finally, we develop goodness of fit tests for the dependency structure in the copula models. We derive a test statistic and its asymptotic properties based on the test of homogeneity of Zelterman and Chen (1988), and a graphical diagnostic procedure based on the empirical Bayes approach. We study the performance of these two methods using actual and computer generated data.

  18. Certification of highly complex safety-related systems.

    PubMed

    Reinert, D; Schaefer, M

    1999-01-01

    The BIA has now 15 years of experience with the certification of complex electronic systems for safety-related applications in the machinery sector. Using the example of machining centres this presentation will show the systematic procedure for verifying and validating control systems using Application Specific Integrated Circuits (ASICs) and microcomputers for safety functions. One section will describe the control structure of machining centres with control systems using "integrated safety." A diverse redundant architecture combined with crossmonitoring and forced dynamization is explained. In the main section the steps of the systematic certification procedure are explained showing some results of the certification of drilling machines. Specification reviews, design reviews with test case specification, statistical analysis, and walk-throughs are the analytical measures in the testing process. Systematic tests based on the test case specification, Electro Magnetic Interference (EMI), and environmental testing, and site acceptance tests on the machines are the testing measures for validation. A complex software driven system is always undergoing modification. Most of the changes are not safety-relevant but this has to be proven. A systematic procedure for certifying software modifications is presented in the last section of the paper.

  19. Design of an x-ray telescope optics for XEUS

    NASA Astrophysics Data System (ADS)

    Graue, Roland; Kampf, Dirk; Wallace, Kotska; Lumb, David; Bavdaz, Marcos; Freyberg, Michael

    2017-11-01

    The X-ray telescope concept for XEUS is based on an innovative high performance and light weight Silicon Pore Optics technology. The XEUS telescope is segmented into 16 radial, thermostable petals providing the rigid optical bench structure of the stand alone XRay High Precision Tandem Optics. A fully representative Form Fit Function (FFF) Model of one petal is currently under development to demonstrate the outstanding lightweight telescope capabilities with high optically effective area. Starting from the envisaged system performance the related tolerance budgets were derived. These petals are made from ceramics, i.e. CeSiC. The structural and thermal performance of the petal shall be reported. The stepwise alignment and integration procedure on petal level shall be described. The functional performance and environmental test verification plan of the Form Fit Function Model and the test set ups are described in this paper. In parallel to the running development activities the programmatic and technical issues wrt. the FM telescope MAIT with currently 1488 Tandem Optics are under investigation. Remote controlled robot supported assembly, simultaneous active alignment and verification testing and decentralised time effective integration procedures shall be illustrated.

  20. Diagnostic Tests and Criterion-Referenced Assessments: Their Contribution to the Resolution of Pupil Learning Difficulties.

    ERIC Educational Resources Information Center

    Simpson, Mary; Arnold, Brian

    1983-01-01

    Suggests that failure to learn is often the result of inappropriateness of level of instruction and deficiencies in instructional procedures and educational strategies, and differentiates between the functions of criterion referenced tests and diagnostic tests. Results are reported from two studies of the teaching of osmosis and photosynthesis.…

  1. An approach for Ewing test selection to support the clinical assessment of cardiac autonomic neuropathy.

    PubMed

    Stranieri, Andrew; Abawajy, Jemal; Kelarev, Andrei; Huda, Shamsul; Chowdhury, Morshed; Jelinek, Herbert F

    2013-07-01

    This article addresses the problem of determining optimal sequences of tests for the clinical assessment of cardiac autonomic neuropathy (CAN). We investigate the accuracy of using only one of the recommended Ewing tests to classify CAN and the additional accuracy obtained by adding the remaining tests of the Ewing battery. This is important as not all five Ewing tests can always be applied in each situation in practice. We used new and unique database of the diabetes screening research initiative project, which is more than ten times larger than the data set used by Ewing in his original investigation of CAN. We utilized decision trees and the optimal decision path finder (ODPF) procedure for identifying optimal sequences of tests. We present experimental results on the accuracy of using each one of the recommended Ewing tests to classify CAN and the additional accuracy that can be achieved by adding the remaining tests of the Ewing battery. We found the best sequences of tests for cost-function equal to the number of tests. The accuracies achieved by the initial segments of the optimal sequences for 2, 3 and 4 categories of CAN are 80.80, 91.33, 93.97 and 94.14, and respectively, 79.86, 89.29, 91.16 and 91.76, and 78.90, 86.21, 88.15 and 88.93. They show significant improvement compared to the sequence considered previously in the literature and the mathematical expectations of the accuracies of a random sequence of tests. The complete outcomes obtained for all subsets of the Ewing features are required for determining optimal sequences of tests for any cost-function with the use of the ODPF procedure. We have also found two most significant additional features that can increase the accuracy when some of the Ewing attributes cannot be obtained. The outcomes obtained can be used to determine the optimal sequences of tests for each individual cost-function by following the ODPF procedure. The results show that the best single Ewing test for diagnosing CAN is the deep breathing heart rate variation test. Optimal sequences found for the cost-function equal to the number of tests guarantee that the best accuracy is achieved after any number of tests and provide an improvement in comparison with the previous ordering of tests or a random sequence. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Orion Ammonia Boiler System Preflight Test Preparations

    NASA Technical Reports Server (NTRS)

    Levitt, Julia L.

    2017-01-01

    The Environmental Controls and Life Support Systems (ECLSS) branch at Kennedy Space Center (KSC) is currently undergoing preparations for ground testing of the Orion Multi-Purpose Crew Vehicle (MPCV) to prepare its subsystems for EM-1 (Exploration Mission-1). EM-1, Orions second unmanned flight, is a three-week long lunar mission during which the vehicle will complete a 6-day retrograde lunar orbit before returning to Earth. This paper focuses on the work done during the authors 16-week internship with the Mechanical Engineering Branch of KSCs Engineering Directorate. The authors project involved assisting with the preparations for testing the Orion MPCVs ammonia boiler system. The purpose of the ammonia boiler system is to keep the spacecraft sufficiently cool during the reentry portion of its mission, from service module (SM) separation to post-landing. This system is critical for keeping both the spacecraft (avionics and electronics) and crew alive during reentry, thus a successful test of the system is essential to the success of EM-1. XXXX The author was able to draft a detailed outline of the procedure for the ammonia system functional test. More work will need to be done on the vehicle power-up and power-down portions of the procedure, but the ammonia system testing portion of the procedure is thorough and includes vehicle test configurations, vehicle commands, and GSE. The author was able to compile a substantial list of questions regarding the ammonia system functional test with the help of her mentors. A significant number of these questions were answered in the teleconferences with Lockheed Martin.

  3. Engineering calculations for communications satellite systems planning

    NASA Technical Reports Server (NTRS)

    Martin, C. H.; Gonsalvez, D. J.; Levis, C. A.; Wang, C. W.

    1983-01-01

    Progress is reported on a computer code to improve the efficiency of spectrum and orbit utilization for the Broadcasting Satellite Service in the 12 GHz band for Region 2. It implements a constrained gradient search procedure using an exponential objective function based on aggregate signal to noise ratio and an extended line search in the gradient direction. The procedure is tested against a manually generated initial scenario and appears to work satisfactorily. In this test it was assumed that alternate channels use orthogonal polarizations at any one satellite location.

  4. Syntactic Categorization in French-Learning Infants

    ERIC Educational Resources Information Center

    Shi, Rushen; Melancon, Andreane

    2010-01-01

    Recent work showed that infants recognize and store function words starting from the age of 6-8 months. Using a visual fixation procedure, the present study tested whether French-learning 14-month-olds have the knowledge of syntactic categories of determiners and pronouns, respectively, and whether they can use these function words for…

  5. Assessing cognitive function in clinical trials: latest developments and future directions.

    PubMed

    Wesnes, Keith

    2002-01-01

    Properly developed automated test systems are of value for assessing changes in cognitive function in clinical trials. Besides the other advantages that automation brings to trials, such as increased reliability and utility, it is shown that such systems are also more sensitive to change in cognitive function than traditional nonautomated procedures. Data from a variety of topical areas in drug development are presented to illustrate the added value such techniques have brought. The latest developments in automation include remote testing via the Internet and telephone.

  6. Modification of the Mantel-Haenszel and Logistic Regression DIF Procedures to Incorporate the SIBTEST Regression Correction

    ERIC Educational Resources Information Center

    DeMars, Christine E.

    2009-01-01

    The Mantel-Haenszel (MH) and logistic regression (LR) differential item functioning (DIF) procedures have inflated Type I error rates when there are large mean group differences, short tests, and large sample sizes.When there are large group differences in mean score, groups matched on the observed number-correct score differ on true score,…

  7. An automated miniaturized Haploscope for testing binocular visual function

    NASA Technical Reports Server (NTRS)

    Decker, T. A.; Williams, R. E.; Kuether, C. L.; Wyman-Cornsweet, D.

    1976-01-01

    A computer-controlled binocular vision testing device has been developed as one part of a system designed for NASA to test the vision of astronauts during spaceflight. The device, called the Mark III Haploscope, utilizes semi-automated psychophysical test procedures to measure visual acuity, stereopsis, phorias, fixation disparity and accommodation/convergence relationships. All tests are self-administered, yield quantitative data and may be used repeatedly without subject memorization. Future applications of this programmable, compact device include its use as a clinical instrument to perform routine eye examinations or vision screening, and as a research tool to examine the effects of environment or work-cycle upon visual function.

  8. Confidence intervals for the first crossing point of two hazard functions.

    PubMed

    Cheng, Ming-Yen; Qiu, Peihua; Tan, Xianming; Tu, Dongsheng

    2009-12-01

    The phenomenon of crossing hazard rates is common in clinical trials with time to event endpoints. Many methods have been proposed for testing equality of hazard functions against a crossing hazards alternative. However, there has been relatively few approaches available in the literature for point or interval estimation of the crossing time point. The problem of constructing confidence intervals for the first crossing time point of two hazard functions is considered in this paper. After reviewing a recent procedure based on Cox proportional hazard modeling with Box-Cox transformation of the time to event, a nonparametric procedure using the kernel smoothing estimate of the hazard ratio is proposed. The proposed procedure and the one based on Cox proportional hazard modeling with Box-Cox transformation of the time to event are both evaluated by Monte-Carlo simulations and applied to two clinical trial datasets.

  9. Multicenter study of pectus excavatum, final report: complications, static/exercise pulmonary function, and anatomic outcomes.

    PubMed

    Kelly, Robert E; Mellins, Robert B; Shamberger, Robert C; Mitchell, Karen K; Lawson, M Louise; Oldham, Keith T; Azizkhan, Richard G; Hebra, Andre V; Nuss, Donald; Goretsky, Michael J; Sharp, Ronald J; Holcomb, George W; Shim, Walton K T; Megison, Stephen M; Moss, R Lawrence; Fecteau, Annie H; Colombani, Paul M; Cooper, Dan; Bagley, Traci; Quinn, Amy; Moskowitz, Alan B; Paulson, James F

    2013-12-01

    A multicenter study of pectus excavatum was described previously. This report presents our final results. Patients treated surgically at 11 centers were followed prospectively. Each underwent a preoperative evaluation with CT scan, pulmonary function tests, and body image survey. Data were collected about associated conditions, complications, and perioperative pain. One year after treatment, patients underwent repeat chest CT scan, pulmonary function tests, and body image survey. A subset of 50 underwent exercise pulmonary function testing. Of 327 patients, 284 underwent Nuss procedure and 43 underwent open procedure without mortality. Of 182 patients with complete follow-up (56%), 18% had late complications, similarly distributed, including substernal bar displacement in 7% and wound infection in 2%. Mean initial CT scan index of 4.4 improved to 3.0 post operation (severe >3.2, normal = 2.5). Computed tomography index improved at the deepest point (xiphoid) and also upper and middle sternum. Pulmonary function tests improved (forced vital capacity from 88% to 93%, forced expiratory volume in 1 second from 87% to 90%, and total lung capacity from 94% to 100% of predicted (p < 0.001 for each). VO2 max during peak exercise increased by 10.1% (p = 0.015) and O2 pulse by 19% (p = 0.007) in 20 subjects who completed both pre- and postoperative exercise tests. There is significant improvement in lung function at rest and in VO2 max and O2 pulse after surgical correction of pectus excavatum, with CT index >3.2. Operative correction significantly reduces CT index and markedly improves the shape of the entire chest, and can be performed safely in a variety of centers. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Electrophysiological assessment of the effects of obstructive sleep apnea on cognition.

    PubMed

    Gelir, Ethem; Başaran, Cenk; Bayrak, Sibel; Yağcıoğlu, Süha; Budak, Murat Timur; Fırat, Hikmet; Ungan, Pekcan

    2014-01-01

    We used electrophysiological measures to investigate the effects of obstructive sleep apnea on attention, learning, and memory. Thirty subjects (OSA group, n = 15, control group n = 15) participated in n-back tests, accompanied by P300 recordings, to investigate working memory and attention. The mirror-drawing test was used to study procedural memory, and the trail-making test (TMT) was used to evaluate divided attention and executive function. No significant group difference in reaction time was found in the 0-back and 1-back tests. In the 2-back test, reaction times of patients were longer than those of the control group. No P300 wave was obtained in the OSA group in any (0-, 1-, or 2-back) n-back test. In contrast, in the control group, significant P300 waves were recorded except for the 2-back test. The mirror-drawing scores were unaffected by sleep apnea. There was no difference between groups in the TMT-A test on any of the trials. Although no group difference was found in the first or second trials of the TMT-B test, OSA patients were less successful in learning on the third trial. According to our study results, OSA affects attention and executive function adversely however, we could not detect a significant effect on working or procedural memory.

  11. Assessment of cardiovascular function following transcatheter aortic valve implantation based on six-minute walk test.

    PubMed

    Chodór, Piotr; Wilczek, Krzysztof; Zielińska, Teresa; Przybylski, Roman; Głowacki, Jan; Włoch, Łukasz; Zembala, Marian; Kalarus, Zbigniew

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) is presently a recognized treatment mo-dality for patients with severe aortic stenosis ineligible for surgery. It reduces mortality as compared to the conservative treatment. It is further expected from this therapy to improve quality of life by improving of the cardiovascular function performance. The aim of this study is to compare patients' cardiovascular system efficiency in the 6-minute walk test (6MWT) made before and after TAVI and at the 6-12-month follow-up. From January 2009 until February 2012, in the Silesian Center for Heart Diseases in Zabrze, TAVI was performed in 104 patients. Eighty-two patients who underwent 6MWT before surgery were qualified for the analysis. The average age of the patients was 76.0 ± 9.17 years, women made 45.1%. The risk of surgical treatment according to the Logistic Euroscore averaged 22.76 ± 12.63%, and by the Society of Thoracic Surgeons - 5.55 ± 3.34%. The 6MWT was performed within 1 month before the TAVI procedure, up to a month after the procedure and during the 6-12-month follow-up. The 6-minute walk test after TAVI was performed by 64 patients, and after 6-12 month follow-up by 46 patients. The average distance in 6MWT increased from 268.4 ± 89.0 m before treat-ment to 290.0 ± 98.2 m after the procedure (p = 0.008) and 276.1 ± 93.5 m to 343.1 ± 96.7 m after 6-12 months (p < 0.0001). Transcatheter aortic valve implantation procedures significantly improve function of the cardiovascular system evaluated by the 6MWT in 1- and 6-12-month observations. (Cardiol J 2017; 24, 2: 167-175).

  12. Ultrasonic interface level analyzer shop test procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    STAEHR, T.W.

    1999-05-24

    The Royce Instrument Corporation Model 2511 Interface Level Analyzer (URSILLA) system uses an ultrasonic ranging technique (SONAR) to measure sludge depths in holding tanks. Three URSILLA instrument assemblies provided by the W-151 project are planned to be used during mixer pump testing to provide data for determining sludge mobilization effectiveness of the mixer pumps and sludge settling rates. The purpose of this test is to provide a documented means of verifying that the functional components of the three URSILLA instruments operate properly. Successful completion of this Shop Test Procedure (STP) is a prerequisite for installation in the AZ-101 tank. Themore » objective of the test is to verify the operation of the URSILLA instruments and to verify data collection using a stand alone software program.« less

  13. 21 CFR 874.1800 - Air or water caloric stimulator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... vestibular function testing of a patient's body balance system. The vestibular stimulation of the...) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in...

  14. Natural disease history of mouse models for limb girdle muscular dystrophy types 2D and 2F

    PubMed Central

    Putker, K.; Tanganyika-de Winter, C. L.; Boertje-van der Meulen, J. W.; van Vliet, L.; Overzier, M.; Plomp, J. J.; Aartsma-Rus, A.; van Putten, M.

    2017-01-01

    Limb-girdle muscular dystrophy types 2D and 2F (LGMD 2D and 2F) are autosomal recessive disorders caused by mutations in the alpha- and delta sarcoglycan genes, respectively, leading to severe muscle weakness and degeneration. The cause of the disease has been well characterized and a number of animal models are available for pre-clinical studies to test potential therapeutic interventions. To facilitate transition from drug discovery to clinical trials, standardized procedures and natural disease history data were collected for these mouse models. Implementing the TREAD-NMD standardized operating procedures, we here subjected LGMD2D (SGCA-null), LGMD2F (SGCD-null) and wild type (C57BL/6J) mice to five functional tests from the age of 4 to 32 weeks. To assess whether the functional test regime interfered with disease pathology, sedentary groups were taken along. Muscle physiology testing of tibialis anterior muscle was performed at the age of 34 weeks. Muscle histopathology and gene expression was analysed in skeletal muscles and heart. Muscle histopathology and gene expression was analysed in skeletal muscles and heart. Mice successfully accomplished the functional tests, which did not interfere with disease pathology. Muscle function of SGCA- and SGCD-null mice was impaired and declined over time. Interestingly, female SGCD-null mice outperformed males in the two and four limb hanging tests, which proved the most suitable non-invasive tests to assess muscle function. Muscle physiology testing of tibialis anterior muscle revealed lower specific force and higher susceptibility to eccentric-induced damage in LGMD mice. Analyzing muscle histopathology and gene expression, we identified the diaphragm as the most affected muscle in LGMD strains. Cardiac fibrosis was found in SGCD-null mice, being more severe in males than in females. Our study offers a comprehensive natural history dataset which will be useful to design standardized tests and future pre-clinical studies in LGMD2D and 2F mice. PMID:28797108

  15. Item Parameter Invariance of the Kaufman Adolescent and Adult Intelligence Test across Male and Female Samples

    ERIC Educational Resources Information Center

    Immekus, Jason C.; Maller, Susan J.

    2009-01-01

    The Kaufman Adolescent and Adult Intelligence Test (KAIT[TM]) is an individually administered test of intelligence for individuals ranging in age from 11 to 85+ years. The item response theory-likelihood ratio procedure, based on the two-parameter logistic model, was used to detect differential item functioning (DIF) in the KAIT across males and…

  16. Children's self reported discomforts as participants in clinical research.

    PubMed

    Staphorst, Mira S; Hunfeld, Joke A M; van de Vathorst, Suzanne; Passchier, Jan; van Goudoever, Johannes B

    2015-10-01

    There is little empirical evidence on children's subjective experiences of discomfort during clinical research procedures. Therefore, Institutional Review Boards have limited empirical information to guide their decision-making on discomforts for children in clinical research. To get more insight into what children's discomforts are during clinical research procedures, we interviewed a group of children on this topic and also asked for suggestions to reduce possible discomforts. Forty-six children (aged 6-18) participating in clinical research studies (including needle-related procedures, food provocation tests, MRI scans, pulmonary function tests, questionnaires) were interviewed about their experiences during the research procedures. Thematic analysis was used to analyze the interviews. The discomforts of the interviewed children could be divided into two main groups: physical and mental discomforts. The majority experienced physical discomforts during the research procedures: pain, shortness of breath, nausea, itchiness, and feeling hungry, which were often caused by needle procedures, some pulmonary procedures, and food provocation tests. Mental discomforts included anxiousness because of anticipated pain and not knowing what to expect from a research procedure, boredom and tiredness during lengthy research procedures and waiting, and embarrassment during Tanner staging. Children's suggestions to reduce the discomforts of the research procedures were providing distraction (e.g. watching a movie or listening to music), providing age-appropriate information and shortening the duration of lengthy procedures. Our study shows that children can experience various discomforts during research procedures, and it provides information about how these discomforts can be reduced according to them. Further research is needed with larger samples to study the number of children that experience these mentioned discomforts during research procedures in a quantitative way. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. New approach to canonical partition functions computation in Nf=2 lattice QCD at finite baryon density

    NASA Astrophysics Data System (ADS)

    Bornyakov, V. G.; Boyda, D. L.; Goy, V. A.; Molochkov, A. V.; Nakamura, Atsushi; Nikolaev, A. A.; Zakharov, V. I.

    2017-05-01

    We propose and test a new approach to computation of canonical partition functions in lattice QCD at finite density. We suggest a few steps procedure. We first compute numerically the quark number density for imaginary chemical potential i μq I . Then we restore the grand canonical partition function for imaginary chemical potential using the fitting procedure for the quark number density. Finally we compute the canonical partition functions using high precision numerical Fourier transformation. Additionally we compute the canonical partition functions using the known method of the hopping parameter expansion and compare results obtained by two methods in the deconfining as well as in the confining phases. The agreement between two methods indicates the validity of the new method. Our numerical results are obtained in two flavor lattice QCD with clover improved Wilson fermions.

  18. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: METSAT A1 Signal Processor (P/N 1331670-2, S/N F03)

    NASA Technical Reports Server (NTRS)

    Lund, D.

    1998-01-01

    This report presents a description of tests performed, and the test data, for the A1 METSAT Signal Processor Assembly PN: 1331679-2, S/N F03. This assembly was tested in accordance with AE-26754, "METSAT Signal Processor Scan Drive Test and Integration Procedure." The objective is to demonstrate functionality of the signal processor prior to instrument integration.

  19. Validation of a New Procedure for Impedance Eduction in Flow

    NASA Technical Reports Server (NTRS)

    Watson, W. R.; Jones, M. G.

    2010-01-01

    A new impedance eduction procedure is validated by comparing the educed impedance spectrum to that of an older but well-tested eduction procedure. The older procedure requires the installation of a microphone array in the liner test section but the new procedure removes this requirement. A 12.7-mm stainless steel plate and a conventional liner consisting of a perforated plate bonded to a honeycomb core are tested. Test data is acquired from a grazing flow, impedance tube facility for a range of source frequencies and mean flow Mach numbers for which only plane waves are cut on. For the stainless steel plate, the educed admittance spectrum using the new procedure shows an improvement over that of the old procedure. This improvement shows up primarily in the educed conductance spectrum. Both eduction procedures show discrepancies in educed admittance in the mid-frequency range. Indications are that this discrepancy is triggered by an inconsistency between the measured eduction data (that contains boundary layer effects) and the two eduction models (for which the boundary layer is neglected). For the conventional liner, both eduction procedures are in very good agreement with each other. Small discrepancies occur for one or two frequencies in the mid-frequency range and for frequencies beyond the cut on frequency of higher-order duct modes. This discrepancy in the midfrequency range occurs because an automated optimizer is used to educe the impedance and the objective function used by the optimizer is extremely flat and therefore sensitive to initial starting values. The discrepancies at frequencies beyond the cut on frequency of higher order duct modes are due to the assumption of only plane waves in the impedance eduction model, although higher order modes are propagating in the impedance tube facility.

  20. Two-loads Method for Distinguishing among the Muscle Force, Velocity, and Power Producing Capacities

    PubMed Central

    Jaric, Slobodan

    2016-01-01

    It has been generally accepted that muscles could have different mechanical capacities, such as those for producing high force (F), velocity (V), and power (P) outputs. Nevertheless, the standard procedures of the evaluation of muscle function both in research and routine testing are typically conducted under a single mechanical condition, such as under a single external load. Therefore, the observed outcomes do not allow for distinguishing among the different muscle capacities. As a result, the outcomes of most of the routine testing procedures have been of limited informational value, while a number of debated issues in research have originated from arbitrarily interpreted experimental findings regarding specific muscle capacities. A solution for the discussed problem could be based on the approximately linear and exceptionally strong F-V relationship typically observed from various functional tasks performed under different external loads. These findings allow for the 'two-loads method' proposed in this Current Opinion: the functional movement tasks (e.g., maximum jumping, cycling, running, pushing, lifting, or throwing) should be tested against just 2 distinctive external loads. Namely, the F-V relationship determined by 2 pairs of the F and V data could provide the parameters depicting the maximum F (i.e., the F-intercept), V (V-intercept), and P (calculated from the product of F and V) output of the tested muscles. Therefore, the proposed two-loads method applied in both research and routine testing could provide a deeper insight into the mechanical properties and function of the tested muscles and resolve a number of debated issues in the literature. PMID:27075326

  1. An evaluation of generalization of mands during functional communication training.

    PubMed

    Falcomata, Terry S; Wacker, David P; Ringdahl, Joel E; Vinquist, Kelly; Dutt, Anuradha

    2013-01-01

    The primary purpose of this study was to evaluate the generalization of mands during functional communication training (FCT) and sign language training across functional contexts (i.e., positive reinforcement, negative reinforcement). A secondary purpose was to evaluate a training procedure based on stimulus control to teach manual signs. During the treatment evaluation, we implemented sign language training in 1 functional context (e.g., positive reinforcement by attention) while continuing the functional analysis conditions in 2 other contexts (e.g., positive reinforcement by tangible item; negative reinforcement by escape). During the generalization evaluation, we tested for the generalization of trained mands across functional contexts (i.e., positive reinforcement; negative reinforcement) by implementing extinction in the 2 nontarget contexts. The results suggested that the stimulus control training procedure effectively taught manual signs and treated destructive behavior. Specific patterns of generalization of trained mands and destructive behavior also were observed. © Society for the Experimental Analysis of Behavior.

  2. Narrative Skills in Young Adults with High-Functioning Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Rollins, Pamela Rosenthal

    2014-01-01

    In this study, the author investigated narrative performances of 10 high-functioning young adults with Autism Spectrum Disorders (ASD) across personal and storybook narratives. Narratives were elicited with genre-specific procedures and then transcribed and scored using the narrative scoring scheme (NSS). One-tailed paired-sample t tests were…

  3. Identifying reprioritization response shift in a stroke caregiver population: a comparison of missing data methods.

    PubMed

    Sajobi, Tolulope T; Lix, Lisa M; Singh, Gurbakhshash; Lowerison, Mark; Engbers, Jordan; Mayo, Nancy E

    2015-03-01

    Response shift (RS) is an important phenomenon that influences the assessment of longitudinal changes in health-related quality of life (HRQOL) studies. Given that RS effects are often small, missing data due to attrition or item non-response can contribute to failure to detect RS effects. Since missing data are often encountered in longitudinal HRQOL data, effective strategies to deal with missing data are important to consider. This study aims to compare different imputation methods on the detection of reprioritization RS in the HRQOL of caregivers of stroke survivors. Data were from a Canadian multi-center longitudinal study of caregivers of stroke survivors over a one-year period. The Stroke Impact Scale physical function score at baseline, with a cutoff of 75, was used to measure patient stroke severity for the reprioritization RS analysis. Mean imputation, likelihood-based expectation-maximization imputation, and multiple imputation methods were compared in test procedures based on changes in relative importance weights to detect RS in SF-36 domains over a 6-month period. Monte Carlo simulation methods were used to compare the statistical powers of relative importance test procedures for detecting RS in incomplete longitudinal data under different missing data mechanisms and imputation methods. Of the 409 caregivers, 15.9 and 31.3 % of them had missing data at baseline and 6 months, respectively. There were no statistically significant changes in relative importance weights on any of the domains when complete-case analysis was adopted. But statistical significant changes were detected on physical functioning and/or vitality domains when mean imputation or EM imputation was adopted. There were also statistically significant changes in relative importance weights for physical functioning, mental health, and vitality domains when multiple imputation method was adopted. Our simulations revealed that relative importance test procedures were least powerful under complete-case analysis method and most powerful when a mean imputation or multiple imputation method was adopted for missing data, regardless of the missing data mechanism and proportion of missing data. Test procedures based on relative importance measures are sensitive to the type and amount of missing data and imputation method. Relative importance test procedures based on mean imputation and multiple imputation are recommended for detecting RS in incomplete data.

  4. A versatile test for equality of two survival functions based on weighted differences of Kaplan-Meier curves.

    PubMed

    Uno, Hajime; Tian, Lu; Claggett, Brian; Wei, L J

    2015-12-10

    With censored event time observations, the logrank test is the most popular tool for testing the equality of two underlying survival distributions. Although this test is asymptotically distribution free, it may not be powerful when the proportional hazards assumption is violated. Various other novel testing procedures have been proposed, which generally are derived by assuming a class of specific alternative hypotheses with respect to the hazard functions. The test considered by Pepe and Fleming (1989) is based on a linear combination of weighted differences of the two Kaplan-Meier curves over time and is a natural tool to assess the difference of two survival functions directly. In this article, we take a similar approach but choose weights that are proportional to the observed standardized difference of the estimated survival curves at each time point. The new proposal automatically makes weighting adjustments empirically. The new test statistic is aimed at a one-sided general alternative hypothesis and is distributed with a short right tail under the null hypothesis but with a heavy tail under the alternative. The results from extensive numerical studies demonstrate that the new procedure performs well under various general alternatives with a caution of a minor inflation of the type I error rate when the sample size is small or the number of observed events is small. The survival data from a recent cancer comparative study are utilized for illustrating the implementation of the process. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Behavioral phenotyping of mice in pharmacological and toxicological research.

    PubMed

    Karl, Tim; Pabst, Reinhard; von Hörsten, Stephan

    2003-07-01

    The evaluation of behavioral effects is an important component for the in vivo screening of drugs or potentially toxic compounds in mice. Ideally, such screening should be composed of monitoring general health, sensory functions, and motor abilities, right before specific behavioral domains are tested. A rational strategy in the design and procedure of testing as well as an effective composition of different well-established and reproducible behavioral tests can minimize the risk of false positive and false negative results in drug screening. In the present review we describe such basic considerations in planning experiments, selecting strains of mice, and propose groups of behavioral tasks suitable for a reliable detection of differences in specific behavioral domains in mice. Screening of general health and neurophysiologic functions (reflexes, sensory abilities) and motor function (pole test, wire hang test, beam walking, rotarod, accelerod, and footprint) as well as specific hypothesis-guided testing in the behavioral domains of learning and memory (water maze, radial maze, conditioned fear, and avoidance tasks), emotionality (open field, hole board, elevated plus maze, and object exploration), nociception (tail flick, hot plate), psychiatric-like conditions (porsolt swim test, acoustic startle response, and prepulse inhibition), and aggression (isolation-induced aggression, spontaneous aggression, and territorial aggression) are described in further detail. This review is designed to describe a general approach, which increases reliability of behavioral screening. Furthermore, it provides an overview on a selection of specific procedures suitable for but not limited to behavioral screening in pharmacology and toxicology.

  6. Interaction Models for Functional Regression.

    PubMed

    Usset, Joseph; Staicu, Ana-Maria; Maity, Arnab

    2016-02-01

    A functional regression model with a scalar response and multiple functional predictors is proposed that accommodates two-way interactions in addition to their main effects. The proposed estimation procedure models the main effects using penalized regression splines, and the interaction effect by a tensor product basis. Extensions to generalized linear models and data observed on sparse grids or with measurement error are presented. A hypothesis testing procedure for the functional interaction effect is described. The proposed method can be easily implemented through existing software. Numerical studies show that fitting an additive model in the presence of interaction leads to both poor estimation performance and lost prediction power, while fitting an interaction model where there is in fact no interaction leads to negligible losses. The methodology is illustrated on the AneuRisk65 study data.

  7. Acceptance-test report for El Toro Library solar heating and cooling demonstration project (SHAC no. 1501)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    A partial acceptance test was conducted on the El Toro Library Solar Energy System, and the detailed results of the various mode acceptance tests are given. All the modes tested function as designed. Collector array efficiencies were calculated at approximately 40%. Chiller COP was estimated at .50, with chiller loop flow rates approximately 85 to 90% of design flow. The acceptance test included visual inspection, preoperational testing and procedure verification, operational mode checkout, and performance testing. (LEW)

  8. Simple procedure for phase-space measurement and entanglement validation

    NASA Astrophysics Data System (ADS)

    Rundle, R. P.; Mills, P. W.; Tilma, Todd; Samson, J. H.; Everitt, M. J.

    2017-08-01

    It has recently been shown that it is possible to represent the complete quantum state of any system as a phase-space quasiprobability distribution (Wigner function) [Phys. Rev. Lett. 117, 180401 (2016), 10.1103/PhysRevLett.117.180401]. Such functions take the form of expectation values of an observable that has a direct analogy to displaced parity operators. In this work we give a procedure for the measurement of the Wigner function that should be applicable to any quantum system. We have applied our procedure to IBM's Quantum Experience five-qubit quantum processor to demonstrate that we can measure and generate the Wigner functions of two different Bell states as well as the five-qubit Greenberger-Horne-Zeilinger state. Because Wigner functions for spin systems are not unique, we define, compare, and contrast two distinct examples. We show how the use of these Wigner functions leads to an optimal method for quantum state analysis especially in the situation where specific characteristic features are of particular interest (such as for spin Schrödinger cat states). Furthermore we show that this analysis leads to straightforward, and potentially very efficient, entanglement test and state characterization methods.

  9. Continuing challenges for computer-based neuropsychological tests.

    PubMed

    Letz, Richard

    2003-08-01

    A number of issues critical to the development of computer-based neuropsychological testing systems that remain continuing challenges to their widespread use in occupational and environmental health are reviewed. Several computer-based neuropsychological testing systems have been developed over the last 20 years, and they have contributed substantially to the study of neurologic effects of a number of environmental exposures. However, many are no longer supported and do not run on contemporary personal computer operating systems. Issues that are continuing challenges for development of computer-based neuropsychological tests in environmental and occupational health are discussed: (1) some current technological trends that generally make test development more difficult; (2) lack of availability of usable speech recognition of the type required for computer-based testing systems; (3) implementing computer-based procedures and tasks that are improvements over, not just adaptations of, their manually-administered predecessors; (4) implementing tests of a wider range of memory functions than the limited range now available; (5) paying more attention to motivational influences that affect the reliability and validity of computer-based measurements; and (6) increasing the usability of and audience for computer-based systems. Partial solutions to some of these challenges are offered. The challenges posed by current technological trends are substantial and generally beyond the control of testing system developers. Widespread acceptance of the "tablet PC" and implementation of accurate small vocabulary, discrete, speaker-independent speech recognition would enable revolutionary improvements to computer-based testing systems, particularly for testing memory functions not covered in existing systems. Dynamic, adaptive procedures, particularly ones based on item-response theory (IRT) and computerized-adaptive testing (CAT) methods, will be implemented in new tests that will be more efficient, reliable, and valid than existing test procedures. These additional developments, along with implementation of innovative reporting formats, are necessary for more widespread acceptance of the testing systems.

  10. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., measurement accuracy, and cut-off. 53.53 Section 53.53 Protection of Environment ENVIRONMENTAL PROTECTION..., measurement accuracy, and cut-off. (a) Overview. This test procedure is designed to evaluate a candidate... measurement accuracy, coefficient of variability measurement accuracy, and the flow rate cut-off function. The...

  11. A harmonic pulse testing method for leakage detection in deep subsurface storage formations

    NASA Astrophysics Data System (ADS)

    Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan

    2015-06-01

    Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

  12. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: METSAT A1 Signal Processor (P/N: 1331670-2, S/N: F04)

    NASA Technical Reports Server (NTRS)

    Lund, D.

    1998-01-01

    This report presents a description of the tests performed, and the test data, for the A1 METSAT Signal Processor Assembly PN: 1331679-2, S/N F04. The assembly was tested in accordance with AE-26754, "METSAT Signal Processor Scan Drive Test and Integration Procedure." The objective is to demonstrate functionality of the signal processor prior to instrument integration.

  13. A Powerful Test for Comparing Multiple Regression Functions.

    PubMed

    Maity, Arnab

    2012-09-01

    In this article, we address the important problem of comparison of two or more population regression functions. Recently, Pardo-Fernández, Van Keilegom and González-Manteiga (2007) developed test statistics for simple nonparametric regression models: Y(ij) = θ(j)(Z(ij)) + σ(j)(Z(ij))∊(ij), based on empirical distributions of the errors in each population j = 1, … , J. In this paper, we propose a test for equality of the θ(j)(·) based on the concept of generalized likelihood ratio type statistics. We also generalize our test for other nonparametric regression setups, e.g, nonparametric logistic regression, where the loglikelihood for population j is any general smooth function [Formula: see text]. We describe a resampling procedure to obtain the critical values of the test. In addition, we present a simulation study to evaluate the performance of the proposed test and compare our results to those in Pardo-Fernández et al. (2007).

  14. Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

    PubMed

    Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L

    2002-01-01

    To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p < 0.001, p = 0.002, and p = 0.009, respectively) after stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

  15. Development and Initial Evaluation of an Acceptance Testing Procedure for Air Supply and Distribution Systems in New Army Facilities

    DTIC Science & Technology

    1988-09-01

    Unfortunately, although current construction practices can produce functional HVAC systems that provide adequate heating and cooling , they do not guarantee...developed by interviewing heating, ventilating, and air-conditioning ( HVAC ) profes- sionals, reviewing technical literature, and consolidating these...for recording this information. A glossary of possibly unfamiliar HVAC terms is included. An informal evaluation of the procedure showed that

  16. A leading edge heating array and a flat surface heating array - operation, maintenance and repair manual

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A general description of the leading edge/flat surface heating array is presented along with its components, assembly instructions, installation instructions, operation procedures, maintenance instructions, repair procedures, schematics, spare parts lists, engineering drawings of the array, and functional acceptance test log sheets. The proper replacement of components, correct torque values, step-by-step maintenance instructions, and pretest checkouts are described.

  17. Guidelines for software inspections

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Quality control inspections are software problem finding procedures which provide defect removal as well as improvements in software functionality, maintenance, quality, and development and testing methodology is discussed. The many side benefits include education, documentation, training, and scheduling.

  18. Advancing Autonomous Operations for Deep Space Vehicles

    NASA Technical Reports Server (NTRS)

    Haddock, Angie T.; Stetson, Howard K.

    2014-01-01

    Starting in Jan 2012, the Advanced Exploration Systems (AES) Autonomous Mission Operations (AMO) Project began to investigate the ability to create and execute "single button" crew initiated autonomous activities [1]. NASA Marshall Space Flight Center (MSFC) designed and built a fluid transfer hardware test-bed to use as a sub-system target for the investigations of intelligent procedures that would command and control a fluid transfer test-bed, would perform self-monitoring during fluid transfers, detect anomalies and faults, isolate the fault and recover the procedures function that was being executed, all without operator intervention. In addition to the development of intelligent procedures, the team is also exploring various methods for autonomous activity execution where a planned timeline of activities are executed autonomously and also the initial analysis of crew procedure development. This paper will detail the development of intelligent procedures for the NASA MSFC Autonomous Fluid Transfer System (AFTS) as well as the autonomous plan execution capabilities being investigated. Manned deep space missions, with extreme communication delays with Earth based assets, presents significant challenges for what the on-board procedure content will encompass as well as the planned execution of the procedures.

  19. Cosmetic surgery procedures as luxury goods: measuring price and demand in facial plastic surgery.

    PubMed

    Alsarraf, Ramsey; Alsarraf, Nicole W; Larrabee, Wayne F; Johnson, Calvin M

    2002-01-01

    To evaluate the relationship between cosmetic facial plastic surgery procedure price and demand, and to test the hypothesis that these procedures function as luxury goods in the marketplace, with an upward-sloping demand curve. Data were derived from a survey that was sent to every (N = 1727) active fellow, member, or associate of the American Academy of Facial Plastic and Reconstructive Surgery, assessing the costs and frequency of 4 common cosmetic facial plastic surgery procedures (face-lift, brow-lift, blepharoplasty, and rhinoplasty) for 1999 and 1989. An economic analysis was performed to assess the relationship of price and demand for these procedures. A significant association was found between increasing surgeons' fees and total charges for cosmetic facial plastic surgery procedures and increasing demand for these procedures, as measured by their annual frequency (P

  20. Integrated Advanced Microwave Sounding Unit-A(AMSU-A). Engineering Test Report: METSAT A1 Signal Processor, (P/N 1331670-2, S /N F05)

    NASA Technical Reports Server (NTRS)

    Lund, D.

    1998-01-01

    This report presents a description of the tests performed, and the test data, for the AI METSAT Signal Processor Assembly P/N 1331670-2, S/N F05. The assembly was tested in accordance with AE-26754, "METSAT Signal Processor Scan Drive and Integration Procedure." The objective is to demonstrate functionality of the signal processor prior to instrument integration.

  1. Task-switching cost and repetition priming: two overlooked confounds in the first-set procedure of the Sternberg paradigm and how they affect memory set-size effects.

    PubMed

    Jou, Jerwen

    2014-10-01

    Subjects performed Sternberg-type memory recognition tasks (Sternberg paradigm) in four experiments. Category-instance names were used as learning and testing materials. Sternberg's original experiments demonstrated a linear relation between reaction time (RT) and memory-set size (MSS). A few later studies found no relation, and other studies found a nonlinear relation (logarithmic) between the two variables. These deviations were used as evidence undermining Sternberg's serial scan theory. This study identified two confounding variables in the fixed-set procedure of the paradigm (where multiple probes are presented at test for a learned memory set) that could generate a MSS RT function that was either flat or logarithmic rather than linearly increasing. These two confounding variables were task-switching cost and repetition priming. The former factor worked against smaller memory sets and in favour of larger sets whereas the latter factor worked in the opposite way. Results demonstrated that a null or a logarithmic RT-to-MSS relation could be the artefact of the combined effects of these two variables. The Sternberg paradigm has been used widely in memory research, and a thorough understanding of the subtle methodological pitfalls is crucial. It is suggested that a varied-set procedure (where only one probe is presented at test for a learned memory set) is a more contamination-free procedure for measuring the MSS effects, and that if a fixed-set procedure is used, it is worthwhile examining the RT function of the very first trials across the MSSs, which are presumably relatively free of contamination by the subsequent trials.

  2. Asphalt compatibility testing using the automated Heithaus titration test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pauli, A.T.

    1996-12-31

    The Heithaus titration test or variations of the test have been used for over 35 years to predict compatibilities of blends of asphalts from different crude sources. Asphalt compatibility is determined from three calculated parameters that measure the state of peptization of an asphalt or asphalt blend. The parameter p{sub a} is a measure of the peptizability of the asphaltenes. The parameter p{sub a} is a measure of the peptizing power of the maltenes, and the parameter P, derived from p{sub a} and p{sub o} values, is a measure of the overall state of peptization of the asphalt or asphaltmore » blend. In Heithaus original procedure, samples of asphalt were dissolved in toluene and titrated with n-heptane in order to initiate flocculation. The onset of flocculation was detected either by photography or by spotting a filter paper with a small amount of the titrated solution. Recently, an {open_quotes}automated{close_quotes} procedure, after Hotier and Robin, has been developed for use with asphalt. In the automated method UV-visible spectrophotometric detection measures the onset of flocculation as a peak with the percent transmittance plotted as a function of the volume of titrating solvent added to a solution of asphalt. The automated procedure has proven to be less operator dependent and much faster than the original Heithaus procedure. Results from the automated procedure show the data to be consistent with results from the original, {open_quotes}classical{close_quotes} Heithaus procedure.« less

  3. Procedure to select test organisms for environmental risk assessment of genetically modified crops in aquatic systems.

    PubMed

    Hilbeck, Angelika; Bundschuh, Rebecca; Bundschuh, Mirco; Hofmann, Frieder; Oehen, Bernadette; Otto, Mathias; Schulz, Ralf; Trtikova, Miluse

    2017-11-01

    For a long time, the environmental risk assessment (ERA) of genetically modified (GM) crops focused mainly on terrestrial ecosystems. This changed when it was scientifically established that aquatic ecosystems are exposed to GM crop residues that may negatively affect aquatic species. To assist the risk assessment process, we present a tool to identify ecologically relevant species usable in tiered testing prior to authorization or for biological monitoring in the field. The tool is derived from a selection procedure for terrestrial ecosystems with substantial but necessary changes to adequately consider the differences in the type of ecosystems. By using available information from the Water Framework Directive (2000/60/EC), the procedure can draw upon existing biological data on aquatic systems. The proposed procedure for aquatic ecosystems was tested for the first time during an expert workshop in 2013, using the cultivation of Bacillus thuringiensis (Bt) maize as the GM crop and 1 stream type as the receiving environment in the model system. During this workshop, species executing important ecological functions in aquatic environments were identified in a stepwise procedure according to predefined ecological criteria. By doing so, we demonstrated that the procedure is practicable with regard to its goal: From the initial long list of 141 potentially exposed aquatic species, 7 species and 1 genus were identified as the most suitable candidates for nontarget testing programs. Integr Environ Assess Manag 2017;13:974-979. © 2017 SETAC. © 2017 SETAC.

  4. Effects of laser procedure for female urodynamic stress incontinence on pad weight, urodynamics, and sexual function.

    PubMed

    Tien, Yi-Wen; Hsiao, Sheng-Mou; Lee, Chien-Nan; Lin, Ho-Hsiung

    2017-03-01

    The impact of the IncontiLase TM procedure on lower urinary tract symptoms (LUTS) remains unclear. Our aim was to evaluate the effects of the IncontiLase TM procedure for urodynamic stress incontinence (USI). All consecutive women with USI prospectively underwent the IncontiLase TM procedure. Urodynamic studies, pad testing, LUTS, and sexual function questionnaires were assessed before and after treatment. Thirty-five women underwent the IncontiLase TM procedure. Among the 28 women with baseline pad weights >1 g, 11 (39.3 %) were objectively cured and 11 (39.3 %) improved. Among the 18 women with mild USI (i.e., baseline pad weight 1-10 g), nine (50 %) were cured and five (27.8 %) improved. Among ten women with baseline pad weight >10 g, two (20 %) were cured and six (60 %) improved. Among the 32 women with complete questionnaire data at 6 months, seven (21.9 %) were subjectively cured, and four (12.5 %) improved. Regarding LUTS, the majority of domains on the King's Health Questionnaire and female sexual desire and function exhibited significant improvements. Forty percent (12/30) of the partners of these patients felt their sexual function had improved at 6 months. Nonetheless, urodynamic values did not differ across the timeline. The effect of the IncontiLase TM procedure for mild USI was moderate at 6-month follow-up but was not effective for pad weight >10 g. Moreover, it improved LUTS, quality of life, QoL, and sexual function of both partners. Further studies should be performed to assess long-term sustained efficacy.

  5. Restoring penis sensation in patients with low spinal cord lesions: the role of the remaining function of the dorsal nerve in a unilateral or bilateral TOMAX procedure.

    PubMed

    Overgoor, Max L E; Braakhekke, Jan P; Kon, Moshe; De Jong, Tom P V M

    2015-04-01

    The recently developed TOMAX-procedure restores unilateral genital sensation, improving sexual health in men with a low spinal lesion (LSL). It connects one dorsal nerve of the penis (DNP) to the intact ipsilateral ilioinguinal nerve. We proposed bilateral neurotization for full sensation of the glans but this entails cutting both DNPs, risking patients' erection/ejaculation ability. The objective was to select patients for a bilateral TOMAX-procedure by measuring remaining DNP function, and perform the first bilateral cases. In 30 LSL patients with no penile- but normal groin sensation selected for a unilateral TOMAX-procedure the integrity of the sacral-reflex-arc and DNP function was tested pre-operatively using bilateral needle electromyography (EMG)-bulbocavernosus reflex (BCR) measurements, and an interview about reflex erections (RE) ability. In 13 spina bifida- and 17 spinal cord injury patients [median age 29.5 years (range 13-59 years), spinal lesion T12 (incomplete) to sacral], seven (23%) patients reported RE, four (57%) with intact BCR, and of nine (30%) patients with intact BCR, four reported RE (44%). Even patients with a LSL and no penile sensation can have signs of remaining DNP function, but cutting both DNPs to restore full glans sensation in a bilateral TOMAX-procedure might interfere with their RE/ejaculation. To avoid this risk, we propose a selecting-protocol for a unilateral- or bilateral procedure using RE and BCR measurements. Using this protocol, three patients were bilaterally operated with promising preliminary results. Full sensation of the glans could lead to further improvement in sexual function. © 2014 Wiley Periodicals, Inc.

  6. Esophageal function testing: Billing and coding update.

    PubMed

    Khan, A; Massey, B; Rao, S; Pandolfino, J

    2018-01-01

    Esophageal function testing is being increasingly utilized in diagnosis and management of esophageal disorders. There have been several recent technological advances in the field to allow practitioners the ability to more accurately assess and treat such conditions, but there has been a relative lack of education in the literature regarding the associated Common Procedural Terminology (CPT) codes and methods of reimbursement. This review, commissioned and supported by the American Neurogastroenterology and Motility Society Council, aims to summarize each of the CPT codes for esophageal function testing and show the trends of associated reimbursement, as well as recommend coding methods in a practical context. We also aim to encourage many of these codes to be reviewed on a gastrointestinal (GI) societal level, by providing evidence of both discrepancies in coding definitions and inadequate reimbursement in this new era of esophageal function testing. © 2017 John Wiley & Sons Ltd.

  7. Alterations in Upper Extremity Motor Function in Soldiers during Acute High Altitude Exposure,

    DTIC Science & Technology

    1988-03-01

    sensitive or controversial items. a°. Encl ALLEN CYMERIAN, Ph.D. c, ARD . SGRD-UEZ ( ) - THRU Chief, Admin Svc Br FROM Commander DATE A p odk CMT 2 TO ak 2...Function orientation and familiarization with all the tests and procedures. Prior to actual sea-level collections , each subject underwent two UEMA

  8. 49 CFR 40.301 - What is the SAP's function in the follow-up evaluation of an employee?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What is the SAP's function in the follow-up evaluation of an employee? 40.301 Section 40.301 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  9. 49 CFR 40.301 - What is the SAP's function in the follow-up evaluation of an employee?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What is the SAP's function in the follow-up evaluation of an employee? 40.301 Section 40.301 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  10. 49 CFR 40.301 - What is the SAP's function in the follow-up evaluation of an employee?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What is the SAP's function in the follow-up evaluation of an employee? 40.301 Section 40.301 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  11. 49 CFR 40.301 - What is the SAP's function in the follow-up evaluation of an employee?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What is the SAP's function in the follow-up evaluation of an employee? 40.301 Section 40.301 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  12. 49 CFR 40.301 - What is the SAP's function in the follow-up evaluation of an employee?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What is the SAP's function in the follow-up evaluation of an employee? 40.301 Section 40.301 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Substance Abuse Professionals and...

  13. Exploring Crossing Differential Item Functioning by Gender in Mathematics Assessment

    ERIC Educational Resources Information Center

    Ong, Yoke Mooi; Williams, Julian; Lamprianou, Iasonas

    2015-01-01

    The purpose of this article is to explore crossing differential item functioning (DIF) in a test drawn from a national examination of mathematics for 11-year-old pupils in England. An empirical dataset was analyzed to explore DIF by gender in a mathematics assessment. A two-step process involving the logistic regression (LR) procedure for…

  14. Antegrade continence enemas improve quality of life in patients with medically-refractory encopresis.

    PubMed

    Church, Joseph T; Simha, Sidd; Wild, Laurie C; Teitelbaum, Daniel H; Ehrlich, Peter F

    2017-05-01

    Fecal incontinence is a socially debilitating problem for many children. We hypothesized that in selected patients with medically-refractory encopresis, placement of an appendicostomy or cecostomy tube for administration of antegrade continence enemas (ACE) would improve quality of life (QOL). We reviewed all patients with encopresis who underwent appendicostomy or cecostomy placement from 2003 to 2014 at our institution. We contacted subjects' parents by phone and administered 3 surveys: a survey reflecting current stooling habits, a disease-specific QOL survey, and the PedsQL™ QOL survey. QOL surveys were completed twice by parents, once reflecting pre-operative QOL, then again reflecting current QOL. Pre-procedure and post-procedure scores were compared by paired t-test. Ten patients underwent appendicostomy/cecostomy for encopresis. Eight completed phone surveys. All procedures were performed laparoscopically. All patients experienced fecal soiling pre-operatively, whereas 5/8 surveyed patients (63%) noted complete resolution of soiling post-procedure (p<0.01). General and disease-specific QOL improved from pre-procedure to post-procedure in the following domains: social habits, physical activity, ability to spend the night elsewhere, feeling, and overall QOL (p<0.05). PedsQL™ scores improved significantly in physical functioning, social functioning, and overall functioning (p<0.05). Antegrade continence enemas significantly improve quality of life in patients with medically-refractory encopresis, likely related to resolution of soiling. 4. Copyright © 2017. Published by Elsevier Inc.

  15. Ghost suppression in image restoration filtering

    NASA Technical Reports Server (NTRS)

    Riemer, T. E.; Mcgillem, C. D.

    1975-01-01

    An optimum image restoration filter is described in which provision is made to constrain the spatial extent of the restoration function, the noise level of the filter output and the rate of falloff of the composite system point-spread away from the origin. Experimental results show that sidelobes on the composite system point-spread function produce ghosts in the restored image near discontinuities in intensity level. By redetermining the filter using a penalty function that is zero over the main lobe of the composite point-spread function of the optimum filter and nonzero where the point-spread function departs from a smoothly decaying function in the sidelobe region, a great reduction in sidelobe level is obtained. Almost no loss in resolving power of the composite system results from this procedure. By iteratively carrying out the same procedure even further reductions in sidelobe level are obtained. Examples of original and iterated restoration functions are shown along with their effects on a test image.

  16. ESTIMATION OF FUNCTIONALS OF SPARSE COVARIANCE MATRICES.

    PubMed

    Fan, Jianqing; Rigollet, Philippe; Wang, Weichen

    High-dimensional statistical tests often ignore correlations to gain simplicity and stability leading to null distributions that depend on functionals of correlation matrices such as their Frobenius norm and other ℓ r norms. Motivated by the computation of critical values of such tests, we investigate the difficulty of estimation the functionals of sparse correlation matrices. Specifically, we show that simple plug-in procedures based on thresholded estimators of correlation matrices are sparsity-adaptive and minimax optimal over a large class of correlation matrices. Akin to previous results on functional estimation, the minimax rates exhibit an elbow phenomenon. Our results are further illustrated in simulated data as well as an empirical study of data arising in financial econometrics.

  17. ESTIMATION OF FUNCTIONALS OF SPARSE COVARIANCE MATRICES

    PubMed Central

    Fan, Jianqing; Rigollet, Philippe; Wang, Weichen

    2016-01-01

    High-dimensional statistical tests often ignore correlations to gain simplicity and stability leading to null distributions that depend on functionals of correlation matrices such as their Frobenius norm and other ℓr norms. Motivated by the computation of critical values of such tests, we investigate the difficulty of estimation the functionals of sparse correlation matrices. Specifically, we show that simple plug-in procedures based on thresholded estimators of correlation matrices are sparsity-adaptive and minimax optimal over a large class of correlation matrices. Akin to previous results on functional estimation, the minimax rates exhibit an elbow phenomenon. Our results are further illustrated in simulated data as well as an empirical study of data arising in financial econometrics. PMID:26806986

  18. Functional and morphological differences following Monarc and TVT-O procedures.

    PubMed

    Huang, W-C; Yang, S-H; Yang, J-M; Tzeng, C-R

    2012-12-01

    To explore function of the lower urinary tract and morphology of tape and urethra following Monarc or TVT-O suburethral tape placement for urodynamic stress incontinence (USI). We recruited prospectively women undergoing either Monarc or TVT-O placement for USI. Before and 3 months after the procedure, participants were evaluated by a question-directed interview, the measures of Sandvik Incontinence Severity Index (SISI), Incontinence Bother Scale (IBS), Ingelman-Sundberg Score (ISS) and short forms of Urogenital Distress Inventory (UDI-6) and Incontinence Impact Questionnaire (IIQ-7), physical examination, a cough stress test and 4D ultrasound investigation. The primary outcome was participants' responses to clinical assessments and the secondary outcome was ultrasound findings. A total of 67 women with Monarc procedures and 60 women with TVT-O procedures completed the survey both preoperatively and 3 months postoperatively. There were significant improvements in scores of SISI, IBS, ISS, UDI-6 and IIQ-7 after both Monarc and TVT-O procedures. At the 3-month follow-up, both procedures had similar success rates, SISI scores, IBS scores, ISS scores, UDI-6 scores and IIQ-7 scores, and similar incidences of postoperative voiding difficulty and overactive bladder symptoms. After Bonferroni correction, all ultrasound parameters representing tape location, tape tension and urethral mobility were similar between the two procedures. At short-term follow-up, Monarc and TVT-O procedures are comparable in both functional outcome of the lower urinary tract and morphology on ultrasound as assessed by parameters representing tape location, tape tension and urethral mobility. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  19. 10 CFR 430.23 - Test procedures for the measurement of energy and water consumption.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... (thereby providing materially inaccurate comparative data), a manufacturer must obtain a waiver in... designed to be activated by a lack of door openings shall not be functional during the energy test. B. The... comparative data), a manufacturer must obtain a waiver in accordance with the relevant provisions of 10 CFR...

  20. 10 CFR 430.23 - Test procedures for the measurement of energy and water consumption.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... (thereby providing materially inaccurate comparative data), a manufacturer must obtain a waiver in... designed to be activated by a lack of door openings shall not be functional during the energy test. B. The... comparative data), a manufacturer must obtain a waiver in accordance with the relevant provisions of 10 CFR...

  1. 10 CFR 430.23 - Test procedures for the measurement of energy and water consumption.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... (thereby providing materially inaccurate comparative data), a manufacturer must obtain a waiver in... designed to be activated by a lack of door openings shall not be functional during the energy test. B. The... comparative data), a manufacturer must obtain a waiver in accordance with the relevant provisions of 10 CFR...

  2. 77 FR 35446 - Self-Regulatory Organizations; BATS Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-13

    ..., maintain, and enforce certain written policies and procedures reasonably designed to comply with the rule...'') (amending Rules 201 and 200 of Regulation SHO to adopt a short sale price test restriction and ``short...'' functionality in connection with the short sale price test restriction; see also, Rule 11.13, which codifies in...

  3. Functional Reading Test Results; Maryland Assessment of State Goals in Reading. Maryland Accountability Program Year IV, School Year 1976-1977.

    ERIC Educational Resources Information Center

    Maryland State Dept. of Education, Baltimore.

    The 1973 statewide (Maryland) educational accountability plan, for which this report was compiled, called for the development and establishment of statewide and local goals in reading, writing, and mathematics; a comprehensive and uniform statewide testing program; procedures for collecting data on student, home, community, and school…

  4. A Monte Carlo Study of an Iterative Wald Test Procedure for DIF Analysis

    ERIC Educational Resources Information Center

    Cao, Mengyang; Tay, Louis; Liu, Yaowu

    2017-01-01

    This study examined the performance of a proposed iterative Wald approach for detecting differential item functioning (DIF) between two groups when preknowledge of anchor items is absent. The iterative approach utilizes the Wald-2 approach to identify anchor items and then iteratively tests for DIF items with the Wald-1 approach. Monte Carlo…

  5. 20 CFR 416.1406 - Testing modifications to the disability determination procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... completed the medical portion of the case review and any applicable residual functional capacity assessment... specializes in a field of medicine appropriate to the child's impairment(s), evaluates the claim of such child...

  6. 20 CFR 416.1406 - Testing modifications to the disability determination procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... completed the medical portion of the case review and any applicable residual functional capacity assessment... specializes in a field of medicine appropriate to the child's impairment(s), evaluates the claim of such child...

  7. 20 CFR 416.1406 - Testing modifications to the disability determination procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... completed the medical portion of the case review and any applicable residual functional capacity assessment... specializes in a field of medicine appropriate to the child's impairment(s), evaluates the claim of such child...

  8. 20 CFR 416.1406 - Testing modifications to the disability determination procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... completed the medical portion of the case review and any applicable residual functional capacity assessment... specializes in a field of medicine appropriate to the child's impairment(s), evaluates the claim of such child...

  9. Tests of Fit for Asymmetric Laplace Distributions with Applications on Financial Data

    NASA Astrophysics Data System (ADS)

    Fragiadakis, Kostas; Meintanis, Simos G.

    2008-11-01

    New goodness-of-fit tests for the family of asymmetric Laplace distributions are constructed. The proposed tests are based on a weighted integral incorporating the empirical characteristic function of suitably standardized data, and can be written in a closed form appropriate for computer implementation. Monte Carlo results show that the new procedure are competitive with classical goodness-of-fit methods. Applications with financial data are also included.

  10. Procedural learning and dyslexia.

    PubMed

    Nicolson, R I; Fawcett, A J; Brookes, R L; Needle, J

    2010-08-01

    Three major 'neural systems', specialized for different types of information processing, are the sensory, declarative, and procedural systems. It has been proposed (Trends Neurosci., 30(4), 135-141) that dyslexia may be attributable to impaired function in the procedural system together with intact declarative function. We provide a brief overview of the increasing evidence relating to the hypothesis, noting that the framework involves two main claims: first that 'neural systems' provides a productive level of description avoiding the underspecificity of cognitive descriptions and the overspecificity of brain structural accounts; and second that a distinctive feature of procedural learning is its extended time course, covering from minutes to months. In this article, we focus on the second claim. Three studies-speeded single word reading, long-term response learning, and overnight skill consolidation-are reviewed which together provide clear evidence of difficulties in procedural learning for individuals with dyslexia, even when the tasks are outside the literacy domain. The educational implications of the results are then discussed, and in particular the potential difficulties that impaired overnight procedural consolidation would entail. It is proposed that response to intervention could be better predicted if diagnostic tests on the different forms of learning were first undertaken. 2010 John Wiley & Sons, Ltd.

  11. Estimation of the Operating Characteristics when the Test Information of the Old Test is not Constant II: Simple Sum Procedure of the Conditional P.D.F. Approach/Normal Approach Method Using Three Subtests of the Old Test. Research Report 80-4.

    ERIC Educational Resources Information Center

    Samejima, Fumiko

    The rationale behind the method of estimating the operating characteristics of discrete item responses when the test information of the Old Test is not constant was presented previously. In the present study, two subtests of the Old Test, i.e. Subtests 1, and 2, each of which has a different non-constant test information function, are used in…

  12. Integrated Advance Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: EOS AMSU-A1 and AMSU-A2 Receivers Assemblies

    NASA Technical Reports Server (NTRS)

    2000-01-01

    This test report presents the test data of the EOS AMSU-A Flight Model No.1 (FM-1) receiver subsystem. The tests are performed per the Acceptance Test Procedure for the AMSU-A Reseiver Subsystem, AE-26002/6A. The functional performance tests are conducted either at the component or subsystem level. While the component-level tests are performed over the entire operating temperature range predicted by thermal analysis, the subsystem-level test are conducted at ambient temperature only.

  13. Nonlinear viscoelastic characterization of structural adhesives

    NASA Technical Reports Server (NTRS)

    Rochefort, M. A.; Brinson, H. F.

    1983-01-01

    Measurements of the nonliner viscoelastic behavior of two adhesives, FM-73 and FM-300, are presented and discussed. Analytical methods to quantify the measurements are given and fitted into a framework of an accelerated testing and analysis procedure. The single integral model used is shown to function well and is analogous to a time-temperature stress-superposition procedure (TTSSP). Advantages and disadvantages of the creep power law method used in this study are given.

  14. Size effect and cylinder test on several commercial explosives

    NASA Astrophysics Data System (ADS)

    Souers, P. Clark; Lauderbach, Lisa; Moua, Kou; Garza, Raul

    2012-03-01

    Some size (diameter) effect and the Cylinder test results for Kinepak (ammonium nitrate/nitromethane), Semtex 1, Semtex H and urea nitrate are presented. Cylinder test data appears normal despite faster sound speeds in the copper wall. Most explosives come to steady state in the Cylinder test as expected, but Kinepak shows a steadily increasing wall velocity with distance down the cylinder. Some data on powder densities as a function of loading procedure are also given.

  15. Waste retrieval sluicing system data acquisition system acceptance test report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bevins, R.R.

    1998-07-31

    This document describes the test procedure for the Project W-320 Tank C-106 Sluicing Data Acquisition System (W-320 DAS). The Software Test portion will test items identified in the WRSS DAS System Description (SD), HNF-2115. Traceability to HNF-2115 will be via a reference that follows in parenthesis, after the test section title. The Field Test portion will test sensor operability, analog to digital conversion, and alarm setpoints for field instrumentation. The W-320 DAS supplies data to assist thermal modeling of tanks 241-C-106 and 241-AY-102. It is designed to be a central repository for information from sources that would otherwise have tomore » be read, recorded, and integrated manually. Thus, completion of the DAS requires communication with several different data collection devices and output to a usable PC data formats. This test procedure will demonstrate that the DAS functions as required by the project requirements stated in Section 3 of the W-320 DAS System Description, HNF-2115.« less

  16. Acquisition of Motor and Cognitive Skills through Repetition in Typically Developing Children

    PubMed Central

    Magallón, Sara; Narbona, Juan; Crespo-Eguílaz, Nerea

    2016-01-01

    Background Procedural memory allows acquisition, consolidation and use of motor skills and cognitive routines. Automation of procedures is achieved through repeated practice. In children, improvement in procedural skills is a consequence of natural neurobiological development and experience. Methods The aim of the present research was to make a preliminary evaluation and description of repetition-based improvement of procedures in typically developing children (TDC). Ninety TDC children aged 6–12 years were asked to perform two procedural learning tasks. In an assembly learning task, which requires predominantly motor skills, we measured the number of assembled pieces in 60 seconds. In a mirror drawing learning task, which requires more cognitive functions, we measured time spent and efficiency. Participants were tested four times for each task: three trials were consecutive and the fourth trial was performed after a 10-minute nonverbal interference task. The influence of repeated practice on performance was evaluated by means of the analysis of variance with repeated measures and the paired-sample test. Correlation coefficients and simple linear regression test were used to examine the relationship between age and performance. Results TDC achieved higher scores in both tasks through repetition. Older children fitted more pieces than younger ones in assembling learning and they were faster and more efficient at the mirror drawing learning task. Conclusions These findings indicate that three consecutive trials at a procedural task increased speed and efficiency, and that age affected basal performance in motor-cognitive procedures. PMID:27384671

  17. Acquisition of Motor and Cognitive Skills through Repetition in Typically Developing Children.

    PubMed

    Magallón, Sara; Narbona, Juan; Crespo-Eguílaz, Nerea

    2016-01-01

    Procedural memory allows acquisition, consolidation and use of motor skills and cognitive routines. Automation of procedures is achieved through repeated practice. In children, improvement in procedural skills is a consequence of natural neurobiological development and experience. The aim of the present research was to make a preliminary evaluation and description of repetition-based improvement of procedures in typically developing children (TDC). Ninety TDC children aged 6-12 years were asked to perform two procedural learning tasks. In an assembly learning task, which requires predominantly motor skills, we measured the number of assembled pieces in 60 seconds. In a mirror drawing learning task, which requires more cognitive functions, we measured time spent and efficiency. Participants were tested four times for each task: three trials were consecutive and the fourth trial was performed after a 10-minute nonverbal interference task. The influence of repeated practice on performance was evaluated by means of the analysis of variance with repeated measures and the paired-sample test. Correlation coefficients and simple linear regression test were used to examine the relationship between age and performance. TDC achieved higher scores in both tasks through repetition. Older children fitted more pieces than younger ones in assembling learning and they were faster and more efficient at the mirror drawing learning task. These findings indicate that three consecutive trials at a procedural task increased speed and efficiency, and that age affected basal performance in motor-cognitive procedures.

  18. Functional retrograde amnesia: a quantitative case study.

    PubMed

    Schacter, D L; Wang, P L; Tulving, E; Freedman, M

    1982-01-01

    The memory impairment of a patient suffering from functional retrograde amnesia was assessed both during the amnesic episode and after its termination. The patient's performance on a task tapping semantic memory was nearly identical on the two test occasions, but his performance on a task tapping episodic memory substantially changed across test sessions. Cueing procedures revealed that in spite of the patient's restricted access to episodic memory during the amnesic period, a relatively intact "island" of episodic memories could be uncovered. The distinction between episodic and semantic memory, as well as the relation between organic and functional retrograde amnesia, are discussed in light of the case study.

  19. The two-sample problem with induced dependent censorship.

    PubMed

    Huang, Y

    1999-12-01

    Induced dependent censorship is a general phenomenon in health service evaluation studies in which a measure such as quality-adjusted survival time or lifetime medical cost is of interest. We investigate the two-sample problem and propose two classes of nonparametric tests. Based on consistent estimation of the survival function for each sample, the two classes of test statistics examine the cumulative weighted difference in hazard functions and in survival functions. We derive a unified asymptotic null distribution theory and inference procedure. The tests are applied to trial V of the International Breast Cancer Study Group and show that long duration chemotherapy significantly improves time without symptoms of disease and toxicity of treatment as compared with the short duration treatment. Simulation studies demonstrate that the proposed tests, with a wide range of weight choices, perform well under moderate sample sizes.

  20. Item Response Theory with Covariates (IRT-C): Assessing Item Recovery and Differential Item Functioning for the Three-Parameter Logistic Model

    ERIC Educational Resources Information Center

    Tay, Louis; Huang, Qiming; Vermunt, Jeroen K.

    2016-01-01

    In large-scale testing, the use of multigroup approaches is limited for assessing differential item functioning (DIF) across multiple variables as DIF is examined for each variable separately. In contrast, the item response theory with covariate (IRT-C) procedure can be used to examine DIF across multiple variables (covariates) simultaneously. To…

  1. An investigation of several numerical procedures for time-asymptotic compressible Navier-Stokes solutions

    NASA Technical Reports Server (NTRS)

    Rudy, D. H.; Morris, D. J.; Blanchard, D. K.; Cooke, C. H.; Rubin, S. G.

    1975-01-01

    The status of an investigation of four numerical techniques for the time-dependent compressible Navier-Stokes equations is presented. Results for free shear layer calculations in the Reynolds number range from 1000 to 81000 indicate that a sequential alternating-direction implicit (ADI) finite-difference procedure requires longer computing times to reach steady state than a low-storage hopscotch finite-difference procedure. A finite-element method with cubic approximating functions was found to require excessive computer storage and computation times. A fourth method, an alternating-direction cubic spline technique which is still being tested, is also described.

  2. Procurement Without Problems: Preparing the RFP.

    ERIC Educational Resources Information Center

    Epstein, Susan Baerg

    1983-01-01

    Discussion of factors contributing to successful procurement of automated library system focuses on preparation of Request for Proposal (RFP) and elements included in the RFP--administrative requirements, functional requirements, performance requirements, reliability requirements, testing procedures, standardized response language, location table,…

  3. 40 CFR 60.424 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to conduct the run, liter/min. B=acid density (a function of acid strength and temperature), g/cc. C=acid strength, decimal fraction. K1/4=conversion factor, 0.0808 (Mg-min-cc)/(g-hr-liter) [0.0891 (ton...

  4. 40 CFR 60.424 - Test methods and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to conduct the run, liter/min. B=acid density (a function of acid strength and temperature), g/cc. C=acid strength, decimal fraction. K1/4=conversion factor, 0.0808 (Mg-min-cc)/(g-hr-liter) [0.0891 (ton...

  5. 40 CFR 60.424 - Test methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... to conduct the run, liter/min. B=acid density (a function of acid strength and temperature), g/cc. C=acid strength, decimal fraction. K1/4=conversion factor, 0.0808 (Mg-min-cc)/(g-hr-liter) [0.0891 (ton...

  6. Statistically generated weighted curve fit of residual functions for modal analysis of structures

    NASA Technical Reports Server (NTRS)

    Bookout, P. S.

    1995-01-01

    A statistically generated weighting function for a second-order polynomial curve fit of residual functions has been developed. The residual flexibility test method, from which a residual function is generated, is a procedure for modal testing large structures in an external constraint-free environment to measure the effects of higher order modes and interface stiffness. This test method is applicable to structures with distinct degree-of-freedom interfaces to other system components. A theoretical residual function in the displacement/force domain has the characteristics of a relatively flat line in the lower frequencies and a slight upward curvature in the higher frequency range. In the test residual function, the above-mentioned characteristics can be seen in the data, but due to the present limitations in the modal parameter evaluation (natural frequencies and mode shapes) of test data, the residual function has regions of ragged data. A second order polynomial curve fit is required to obtain the residual flexibility term. A weighting function of the data is generated by examining the variances between neighboring data points. From a weighted second-order polynomial curve fit, an accurate residual flexibility value can be obtained. The residual flexibility value and free-free modes from testing are used to improve a mathematical model of the structure. The residual flexibility modal test method is applied to a straight beam with a trunnion appendage and a space shuttle payload pallet simulator.

  7. A manual therapy and exercise approach to meralgia paresthetica in pregnancy: a case report

    PubMed Central

    Skaggs, Clayton D.; Winchester, Brett A.; Vianin, Michael; Prather, Heidi

    2006-01-01

    Abstract Objective To present a case of a pregnant patient with meralgia paresthetica who improved using manual therapy and exercise procedures. Clinical Features A 22-year-old patient in the sixteenth week of pregnancy had low back pain, bilateral anterolateral thigh paresthesia and groin pain for a duration of 1 month. She had no motor deficits in either lower extremity and her reflexes were intact. As a standard clinic procedure, a battery of functional tests were performed including: active straight leg raise, long dorsal ligament test, and the pelvic pain provocation procedure. Based on her clinical history and physical responses to the aforementioned functional tests, the diagnosis of meralgia paresthetica was deduced. Intervention and Outcome Treatment was provided at 6 visits over a 6-week period where the patient underwent evaluation, manual intervention, and exercise prescription. Active Release Technique (ART) was performed to the restricted right sacroiliac (SIJ) complex and quadratus lumborum muscles. ART and post-isometric relaxation were applied to the illiopsoas muscles. The home exercise program consisted of pelvic/low back mobility, stabilization and relaxation exercises. After 6 treatments, the patient reported complete resolution of low back pain and left lower extremity symptoms and a 90% improvement in the right thigh symptoms. At her one-year follow-up, the patient reported no further complications and the absence of pain. Conclusions Manual therapy and exercises may serve as an effective treatment protocol for pregnant patients experiencing low back pain complicated by paresthesia. Because these conservative procedures offer a low-risk intervention, additional clinical studies are warranted to further study this treatment. PMID:19674679

  8. Probability density function approach for compressible turbulent reacting flows

    NASA Technical Reports Server (NTRS)

    Hsu, A. T.; Tsai, Y.-L. P.; Raju, M. S.

    1994-01-01

    The objective of the present work is to extend the probability density function (PDF) tubulence model to compressible reacting flows. The proability density function of the species mass fractions and enthalpy are obtained by solving a PDF evolution equation using a Monte Carlo scheme. The PDF solution procedure is coupled with a compression finite-volume flow solver which provides the velocity and pressure fields. A modeled PDF equation for compressible flows, capable of treating flows with shock waves and suitable to the present coupling scheme, is proposed and tested. Convergence of the combined finite-volume Monte Carlo solution procedure is discussed. Two super sonic diffusion flames are studied using the proposed PDF model and the results are compared with experimental data; marked improvements over solutions without PDF are observed.

  9. A Procedure for High Resolution Satellite Imagery Quality Assessment

    PubMed Central

    Crespi, Mattia; De Vendictis, Laura

    2009-01-01

    Data products generated from High Resolution Satellite Imagery (HRSI) are routinely evaluated during the so-called in-orbit test period, in order to verify if their quality fits the desired features and, if necessary, to obtain the image correction parameters to be used at the ground processing center. Nevertheless, it is often useful to have tools to evaluate image quality also at the final user level. Image quality is defined by some parameters, such as the radiometric resolution and its accuracy, represented by the noise level, and the geometric resolution and sharpness, described by the Modulation Transfer Function (MTF). This paper proposes a procedure to evaluate these image quality parameters; the procedure was implemented in a suitable software and tested on high resolution imagery acquired by the QuickBird, WorldView-1 and Cartosat-1 satellites. PMID:22412312

  10. Resampling-Based Empirical Bayes Multiple Testing Procedures for Controlling Generalized Tail Probability and Expected Value Error Rates: Focus on the False Discovery Rate and Simulation Study

    PubMed Central

    Dudoit, Sandrine; Gilbert, Houston N.; van der Laan, Mark J.

    2014-01-01

    Summary This article proposes resampling-based empirical Bayes multiple testing procedures for controlling a broad class of Type I error rates, defined as generalized tail probability (gTP) error rates, gTP(q, g) = Pr(g(Vn, Sn) > q), and generalized expected value (gEV) error rates, gEV(g) = E[g(Vn, Sn)], for arbitrary functions g(Vn, Sn) of the numbers of false positives Vn and true positives Sn. Of particular interest are error rates based on the proportion g(Vn, Sn) = Vn/(Vn + Sn) of Type I errors among the rejected hypotheses, such as the false discovery rate (FDR), FDR = E[Vn/(Vn + Sn)]. The proposed procedures offer several advantages over existing methods. They provide Type I error control for general data generating distributions, with arbitrary dependence structures among variables. Gains in power are achieved by deriving rejection regions based on guessed sets of true null hypotheses and null test statistics randomly sampled from joint distributions that account for the dependence structure of the data. The Type I error and power properties of an FDR-controlling version of the resampling-based empirical Bayes approach are investigated and compared to those of widely-used FDR-controlling linear step-up procedures in a simulation study. The Type I error and power trade-off achieved by the empirical Bayes procedures under a variety of testing scenarios allows this approach to be competitive with or outperform the Storey and Tibshirani (2003) linear step-up procedure, as an alternative to the classical Benjamini and Hochberg (1995) procedure. PMID:18932138

  11. Improving balance, mobility, and dual-task performance in an adolescent with cerebral palsy: A case report.

    PubMed

    Fisher-Pipher, Sarah; Kenyon, Lisa K; Westman, Marci

    2017-07-01

    Improving functional mobility is often a desired outcome for adolescents with cerebral palsy (CP). Traditional neurorehabilitation approaches are frequently directed at impairments; however, improvements may not be carried over into functional mobility. The purpose of this case report was to describe the examination, intervention, and outcomes of a task-oriented physical therapy intervention program to improve dynamic balance, functional mobility, and dual-task performance in an adolescent with CP. The participant was a 15-year-old girl with spastic triplegic CP (Gross Motor Classification System Level II). Examination procedures included the Canadian Occupational Performance Measure, 6-minute walk test, Muscle Power Sprint Test, 10 x 5-meter sprint test, Timed Up and Down Stairs Test, Gross Motor Function Measure, Gillette Functional Assessment Questionnaire, and functional lower extremity strength tests. Intervention focused on task-oriented dynamic balance and mobility tasks that incorporated coordination and speed demands as well as task-specific lower extremity and trunk strengthening activities. Dual task demands were integrated into all intervention activities. Post-intervention testing revealed improvements in cardiovascular endurance, anaerobic power, agility, stair climbing, gross motor skills, and mobility. The participant appeared to benefit from a task-oriented program to improve dynamic balance, functional mobility, and dual-task performance.

  12. A sup-score test for the cure fraction in mixture models for long-term survivors.

    PubMed

    Hsu, Wei-Wen; Todem, David; Kim, KyungMann

    2016-12-01

    The evaluation of cure fractions in oncology research under the well known cure rate model has attracted considerable attention in the literature, but most of the existing testing procedures have relied on restrictive assumptions. A common assumption has been to restrict the cure fraction to a constant under alternatives to homogeneity, thereby neglecting any information from covariates. This article extends the literature by developing a score-based statistic that incorporates covariate information to detect cure fractions, with the existing testing procedure serving as a special case. A complication of this extension, however, is that the implied hypotheses are not typical and standard regularity conditions to conduct the test may not even hold. Using empirical processes arguments, we construct a sup-score test statistic for cure fractions and establish its limiting null distribution as a functional of mixtures of chi-square processes. In practice, we suggest a simple resampling procedure to approximate this limiting distribution. Our simulation results show that the proposed test can greatly improve efficiency over tests that neglect the heterogeneity of the cure fraction under the alternative. The practical utility of the methodology is illustrated using ovarian cancer survival data with long-term follow-up from the surveillance, epidemiology, and end results registry. © 2016, The International Biometric Society.

  13. Short-term effect of TVT-SECUR procedure on quality of life and sexual function in women with stress urinary incontinence.

    PubMed

    Tang, Xiang; Zhu, Lan; Zhong, Wen; Li, Bin; Lang, Jinghe

    2013-01-01

    To investigate whether patient quality of life and sexual function are improved after the tension-free vaginal tape SECUR (TVT-S) procedure (H-type). Prospective study (Canadian Task Force classification II-3). Single-center hospital. Thirty-three women with stress urinary incontinence (SUI) (high urethral mobility) and no concomitant pelvic floor prolapse underwent TVT-S between October 2009 and October 2011. TVT-S procedure. Before and after surgery(6 and 12 months), all patients completed the Chinese version of the Incontinence Quality of Life Questionnaire (I-QOL). In addition, 28 sexually active patients who underwent the TVT-S procedure completed the short-form Pelvic Organ Prolapse/Urinary Incontinence Sexual Function Questionnaire (PISQ-12) before and after surgery (6 and 12 months). We used a paired t test to compare I-QOL scores before and after surgery. The Wilcoxon signed-rank test was used to compare the preoperative and postoperative PISQ scores. The objective cure rate was 78% (26 of 33 patients) at 12 months after surgery. The objective improvement rate was 12.1% (4 of 33 patients). The subjective satisfaction rate was 90%. Three operations (9.1%) were considered failures. Two patients underwent a TVT procedure after TVT-S because of recurrence. No patients reported severe pain; the mean (SD) visual analog scale pain score was 1.8 (1.2) after surgery. Only 1 patient (3%) was found to have sling erosion at 12 months postoperatively. The I-QOL score was 28.3 (14.2) before surgery and increased to 69.5 (18.9) at 12 months after the TVT-S procedure. The I-QOL score improved significantly after surgery (p <.001). The total PISQ-12 score at 6 months after surgery in all sexually active patients was 33.82 (0.87), compared with 31.57 (1.20) before surgery (p <.05). Physical domain scores on the PISQ-12 demonstrated significant improvement, increasing from 12.61 (0.75) to 14.36 (0.49) (p <.05). No significant difference was found between I-QOL and PISQ-12 scores at 6 and 12 months after surgery. There was no significant difference in total PISQ-12 scores in premenopausal patients before and after surgery (p >.05). Although the objective cure rate was not high, the TVT-S procedure is a minimally invasive, safe, and effective surgical procedure for treatment of SUI (high urethral mobility) and can improve the quality of life and sexual function in women with SUI. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  14. A Comparison of Item Exposure Control Procedures with the Generalized Partial Credit Model

    ERIC Educational Resources Information Center

    Sanchez, Edgar Isaac

    2008-01-01

    To enhance test security of high stakes tests, it is vital to understand the way various exposure control strategies function under various IRT models. To that end the present dissertation focused on the performance of several exposure control strategies under the generalized partial credit model with an item pool of 100 and 200 items. These…

  15. Instruction manual model 600F, data transmission test set

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Information necessary for the operation and maintenance of the Model 600F Data Transmission Test Set is presented. A description is contained of the physical and functional characteristics; pertinent installation data; instructions for operating the equipment; general and detailed principles of operation; preventive and corrective maintenance procedures; and block, logic, and component layout diagrams of the equipment and its major component assemblies.

  16. Bayesian model checking: A comparison of tests

    NASA Astrophysics Data System (ADS)

    Lucy, L. B.

    2018-06-01

    Two procedures for checking Bayesian models are compared using a simple test problem based on the local Hubble expansion. Over four orders of magnitude, p-values derived from a global goodness-of-fit criterion for posterior probability density functions agree closely with posterior predictive p-values. The former can therefore serve as an effective proxy for the difficult-to-calculate posterior predictive p-values.

  17. Effects of High-Flux versus Low-Flux Membranes on Pulmonary Function Tests in Hemodialysis Patients.

    PubMed

    Momeni, Ali; Rouhi, Hamid; Kiani, Glareh; Amiri, Masoud

    2013-01-01

    Several studies have been carried out to evaluate the effects of dialysis on pulmonary function tests (PFT). Dialysis procedure may reduce lung volumes and capacities or cause hypoxia; however, to the best of our knowledge, there is no previous study evaluating the effects of membrane type (high flux vs. low flux) on PFT in these patients. The aim of this study was the evaluation of this relationship. In this cross-sectional study, 43 hemodialysis patients without pulmonary disease were enrolled. In these patients dialysis was conducted by low-and high-flux membranes and before and after the procedure, spirometry was done and the results were evaluated by t-test and chi square test. The mean age of patients was 56.34 years. Twenty-three of them were female (53.5%). Type of membrane (high flux vs. low flux) had no effect on spirometry results of patients despite the significant decrease in the body weight during the dialysis session. High flux membrane had no advantage over low flux membrane in terms of improvement in spirometry findings; thus, we could not offer these expensive membranes for this purpose.

  18. Efficient fractal-based mutation in evolutionary algorithms from iterated function systems

    NASA Astrophysics Data System (ADS)

    Salcedo-Sanz, S.; Aybar-Ruíz, A.; Camacho-Gómez, C.; Pereira, E.

    2018-03-01

    In this paper we present a new mutation procedure for Evolutionary Programming (EP) approaches, based on Iterated Function Systems (IFSs). The new mutation procedure proposed consists of considering a set of IFS which are able to generate fractal structures in a two-dimensional phase space, and use them to modify a current individual of the EP algorithm, instead of using random numbers from different probability density functions. We test this new proposal in a set of benchmark functions for continuous optimization problems. In this case, we compare the proposed mutation against classical Evolutionary Programming approaches, with mutations based on Gaussian, Cauchy and chaotic maps. We also include a discussion on the IFS-based mutation in a real application of Tuned Mass Dumper (TMD) location and optimization for vibration cancellation in buildings. In both practical cases, the proposed EP with the IFS-based mutation obtained extremely competitive results compared to alternative classical mutation operators.

  19. Quantification of the Upper Extremity Motor Functions of Stroke Patients Using a Smart Nine-Hole Peg Tester

    PubMed Central

    Marik, Anikó Rita; Fazekas, Gábor

    2018-01-01

    This paper introduces a smart nine-hole peg tester (s-9HPT), which comprises a standard nine-hole peg test pegboard, but with light-emitting diodes (LEDs) next to each hole. The s-9HPT still supports the traditional nine-hole peg test operating mode, in which the order of the peg placement and removal can be freely chosen. Considering this, the s-9HPT was used in lab research to analyze the traditional procedure and possible new procedures. As this analysis required subjects with similar levels of dexterity, measurement data from 16 healthy subjects (seven females, nine males, 25–80 years old) were used. We consequently found that illuminating the LEDs in various patterns facilitated guided tests of diverse complexity levels. Next, to demonstrate the clinical application of the s-9HPT, the improvement in the hand dexterity of 12 hospitalized stroke patients (45–80 years old, six females and six males) was monitored during their rehabilitation. Here, we used traditional and guided tests validated by healthy subjects. Consequently, improvements were found to be patient specific. At the beginning of rehabilitation, traditional tests suitably indicate improvements, while guided tests are beneficial following improvements in motor functions. Further, the guided tests motivated certain patients, meaning the rehabilitation was more effective for these individuals. PMID:29850001

  20. Test Operations Procedure (TOP) 6-3-044. Optical Transfer Function

    DTIC Science & Technology

    2009-07-27

    Mounting Fixtures As required Alignment Periscope See section 4.1.6 TOP 6-3-040 27 July 2009 3 3. REQUIRED TEST CONDITIONS. 3.1 Pre-test...carefully selected. The stabilized cast iron lathe bed type, typically 2-3 m long, provides adequate support for mounting the various assemblies...combined size and weight of some vehicle mounted sights, a special mounting fixture , perhaps including a periscopic system may be required. It is

  1. Understanding Rasch Measurement: Rasch Techniques for Detecting Bias in Performance Assessments: An Example Comparing the Performance of Native and Non-native Speakers on a Test of Academic English.

    ERIC Educational Resources Information Center

    Elder, Catherine; McNamara, Tim; Congdon, Peter

    2003-01-01

    Used Rasch analytic procedures to study item bias or differential item functioning in both dichotomous and scalar items on a test of English for academic purposes. Results for 139 college students on a pilot English language test model the approach and illustrate the measurement challenges posed by a diagnostic instrument to measure English…

  2. Portable apparatus with CRT display for nondestructive testing of concrete by the ultrasonic pulse method

    NASA Technical Reports Server (NTRS)

    Manta, G.; Gurau, Y.; Nica, P.; Facacaru, I.

    1974-01-01

    The development of methods for the nondestructive study of concrete structures is discussed. The nondestructive test procedure is based on the method of ultrasonic pulse transmission through the material. The measurements indicate that the elastic properties of concrete or other heterogeneous materials are a function of the rate of ultrasonic propagation. Diagrams of the test equipment are provided. Mathematical models are included to support the theoretical aspects.

  3. Occupational Survey Report, Cardiopulmonary Laboratory, AFSC 4H0X1, OSSN: 2541

    DTIC Science & Technology

    2004-02-01

    patients within facility 97 E0211 Set up humidifiers 97 E0175 Instruct patients in use of incentive spirometers 97 A0031 Obtain sputum samples 97 A0026...D0137 Calibrate pulmonary function testing equipment 100 D0150 Perform routine spirometry tests 100 D0146 Perform lung diffusion tests 100 A0042 Perform...consultations, or procedures 31 D0150 Perform routine spirometry tests 23 35 TABLE A2 REPRESENTATIVE TASKS PERFORMED BY MEMBERS IN THE SUPERVISION AND

  4. Use of Metallic Endosseous Implants as a Tooth Substitute.

    DTIC Science & Technology

    1979-06-01

    exposed in the oral cavity and placed in function with the opposing dentition iBACKGROUND The development of a dental implant that will serve as a...contract year was spent in testing the dental implant as a single tooth replacement. The ultimate goal of this implant study was to develop a free-standing...to read and sign an informed consent form. SURGICAL PROCEDURES The dental implant was inserted into the edentulous area using the exact procedures as

  5. APPROACHES TO ASSESSING THE VALIDITY OF A FUNCTIONAL OBSERVATIONAL BATTERY

    EPA Science Inventory

    With the growing importance of neurobehavioral assessments at the preliminary stage of chemical testing, it is critical that the screening procedures utilized be valid indicators of neurobehavioral dysfunction in addition to being sensitive, specific, and reliable. fforts in this...

  6. Project W-320 acceptance test report for AY-farm electrical distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bevins, R.R.

    1998-04-02

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the AY-Farm Electrical Distribution System functions as required by the design criteria. This test is divided into three parts to support the planned construction schedule; Section 8 tests Mini-Power Pane AY102-PPI and the EES; Section 9 tests the SSS support systems; Section 10 tests the SSS and the Multi-Pak Group Control Panel. This test does not include the operation of end-use components (loads) supplied from the distribution system. Tests of the end-use components (loads) will be performed by other W-320 ATPs.

  7. Impairment in proverb interpretation as an executive function deficit in patients with amnestic mild cognitive impairment and early Alzheimer's disease.

    PubMed

    Leyhe, Thomas; Saur, Ralf; Eschweiler, Gerhard W; Milian, Monika

    2011-01-01

    Proverb interpretation is assumed to reflect executive functions. We hypothesized that proverb interpretation is impaired in patients with amnestic mild cognitive impairment (aMCI) diagnosed as single-domain impairment by common neuropsychological testing. We compared performance in a proverb interpretation test in single-domain aMCI patients and patients with early Alzheimer's disease (EAD). The groups with aMCI and EAD performed significantly worse than healthy controls. Both patient groups gave concrete answers with a similar frequency. However, patients with EAD tended to give senseless answers more frequently. Our data suggest that in patients diagnosed as single-domain aMCI, deterioration of executive functions is detectable with subtle and appropriate neuropsychological testing. Implementation of these procedures may improve the early prediction of AD.

  8. SDO FlatSat Facility

    NASA Technical Reports Server (NTRS)

    Amason, David L.

    2008-01-01

    The goal of the Solar Dynamics Observatory (SDO) is to understand and, ideally, predict the solar variations that influence life and society. It's instruments will measure the properties of the Sun and will take hifh definition images of the Sun every few seconds, all day every day. The FlatSat is a high fidelity electrical and functional representation of the SDO spacecraft bus. It is a high fidelity test bed for Integration & Test (I & T), flight software, and flight operations. For I & T purposes FlatSat will be a driver to development and dry run electrical integration procedures, STOL test procedures, page displays, and the command and telemetry database. FlatSat will also serve as a platform for flight software acceptance and systems testing for the flight software system component including the spacecraft main processors, power supply electronics, attitude control electronic, gimbal control electrons and the S-band communications card. FlatSat will also benefit the flight operations team through post-launch flight software code and table update development and verification and verification of new and updated flight operations products. This document highlights the benefits of FlatSat; describes the building of FlatSat; provides FlatSat facility requirements, access roles and responsibilities; and, and discusses FlatSat mechanical and electrical integration and functional testing.

  9. Kernel Machine SNP-set Testing under Multiple Candidate Kernels

    PubMed Central

    Wu, Michael C.; Maity, Arnab; Lee, Seunggeun; Simmons, Elizabeth M.; Harmon, Quaker E.; Lin, Xinyi; Engel, Stephanie M.; Molldrem, Jeffrey J.; Armistead, Paul M.

    2013-01-01

    Joint testing for the cumulative effect of multiple single nucleotide polymorphisms grouped on the basis of prior biological knowledge has become a popular and powerful strategy for the analysis of large scale genetic association studies. The kernel machine (KM) testing framework is a useful approach that has been proposed for testing associations between multiple genetic variants and many different types of complex traits by comparing pairwise similarity in phenotype between subjects to pairwise similarity in genotype, with similarity in genotype defined via a kernel function. An advantage of the KM framework is its flexibility: choosing different kernel functions allows for different assumptions concerning the underlying model and can allow for improved power. In practice, it is difficult to know which kernel to use a priori since this depends on the unknown underlying trait architecture and selecting the kernel which gives the lowest p-value can lead to inflated type I error. Therefore, we propose practical strategies for KM testing when multiple candidate kernels are present based on constructing composite kernels and based on efficient perturbation procedures. We demonstrate through simulations and real data applications that the procedures protect the type I error rate and can lead to substantially improved power over poor choices of kernels and only modest differences in power versus using the best candidate kernel. PMID:23471868

  10. Comprehensive evaluation of lung allograft function in infants after lung and heart-lung transplantation.

    PubMed

    Hayes, Don; Naguib, Aymen; Kirkby, Stephen; Galantowicz, Mark; McConnell, Patrick I; Baker, Peter B; Kopp, Benjamin T; Lloyd, Eric A; Astor, Todd L

    2014-05-01

    Limited data exist on methods to evaluate allograft function in infant recipients of lung and heart-lung transplants. At our institution, we developed a procedural protocol in coordination with pediatric anesthesia where infants were sedated to perform infant pulmonary function testing, computed tomography imaging of the chest, and flexible fiberoptic bronchoscopy with transbronchial biopsies. A retrospective review was performed of children aged younger than 1 year who underwent lung or heart-lung transplantation at our institution to assess the effect of this procedural protocol in the evaluation of infant lung allografts. Since 2005, 5 infants have undergone thoracic transplantation (3 heart-lung, 2 lung). At time of transplant, the mean ± standard deviation age was 7.2 ± 2.8 months (range, 3-11 months). Of 24 procedural sessions performed to evaluate lung allografts, 83% (20 of 24) were considered surveillance where the patients were completely asymptomatic. Of the surveillance procedures, 80% were performed as an outpatient, whereas 20% were done as inpatients during the lung or heart-lung transplant post-operative period before discharge home. Sedation was performed with propofol alone (23 of 24) or in addition to ketamine (1 of 24) infusion; mean sedation time was 141 ± 39 minutes (range, 70-214) minutes. Of the 16 outpatient procedures, patients were discharged after 14 (88%) on the same day, and after 2 (12%) were admitted for observation, with 1 being due to transportation issues and the other due to fever during the observation period. A comprehensive procedural protocol to evaluate allograft function in infant lung and heart-lung transplant recipients was performed safely as an outpatient. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  11. Implementation Considerations for Multisite Clinical Trials with Cognitive Neuroscience Tasks

    PubMed Central

    Keefe, Richard S. E.; Harvey, Philip D.

    2008-01-01

    Multisite clinical trials aimed at cognitive enhancement across various neuropsychiatric conditions have employed standard neuropsychological tests as outcome measures. While these tests have enjoyed wide clinical use and have proven reliable and predictive of functional disability, a number of implementation challenges have arisen when these tests are used in clinical trials. These issues are likely to be magnified in future studies when cognitive neuroscience (CN) procedures are explored in these trials, because in their current forms CN procedures are less standardized and more difficult to teach and monitor. For multisite trials, we anticipate that the most challenging issues will include assuring tester competence, monitoring tester performance, specific challenges with complex assessment methods, and having resources available for adequate monitoring of data quality. Suggestions for overcoming these implementation challenges are offered. PMID:18495645

  12. PDF approach for compressible turbulent reacting flows

    NASA Technical Reports Server (NTRS)

    Hsu, A. T.; Tsai, Y.-L. P.; Raju, M. S.

    1993-01-01

    The objective of the present work is to develop a probability density function (pdf) turbulence model for compressible reacting flows for use with a CFD flow solver. The probability density function of the species mass fraction and enthalpy are obtained by solving a pdf evolution equation using a Monte Carlo scheme. The pdf solution procedure is coupled with a compressible CFD flow solver which provides the velocity and pressure fields. A modeled pdf equation for compressible flows, capable of capturing shock waves and suitable to the present coupling scheme, is proposed and tested. Convergence of the combined finite-volume Monte Carlo solution procedure is discussed, and an averaging procedure is developed to provide smooth Monte-Carlo solutions to ensure convergence. Two supersonic diffusion flames are studied using the proposed pdf model and the results are compared with experimental data; marked improvements over CFD solutions without pdf are observed. Preliminary applications of pdf to 3D flows are also reported.

  13. Incorporating Data Link Messaging into a Multi-function Display for General Aviation Aircraft

    NASA Technical Reports Server (NTRS)

    Adams, Catherine A.; Murdoch, Jennifer L.

    2006-01-01

    One objective of the Small Aircraft Transportation System (SATS) Project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated system and separation responsibilities to general aviation (GA) pilots. This paper describes the development of a research multi-function display (MFD) to support the interaction between pilots and an automated Airport Management Module (AMM). Preliminary results of simulation and flight tests indicate that adding the responsibility of monitoring other traffic for self-separation does not increase pilots subjective workload levels. Pilots preferred using the enhanced MFD to execute flight procedures, reporting improved situation awareness over conventional instrument flight rules (IFR) procedures.

  14. Development and evaluation of the impulse transfer function technique

    NASA Technical Reports Server (NTRS)

    Mantus, M.

    1972-01-01

    The development of the test/analysis technique known as the impulse transfer function (ITF) method is discussed. This technique, when implemented with proper data processing systems, should become a valuable supplement to conventional dynamic testing and analysis procedures that will be used in the space shuttle development program. The method can relieve many of the problems associated with extensive and costly testing of the shuttle for transient loading conditions. In addition, the time history information derived from impulse testing has the potential for being used to determine modal data for the structure under investigation. The technique could be very useful in determining the time-varying modal characteristics of structures subjected to thermal transients, where conventional mode surveys are difficult to perform.

  15. Interdisciplinary Development of an Improved Emergency Department Procedural Work Surface Through Iterative Design and Use Testing in Simulated and Clinical Environments.

    PubMed

    Zhang, Xiao C; Bermudez, Ana M; Reddy, Pranav M; Sarpatwari, Ravi R; Chheng, Darin B; Mezoian, Taylor J; Schwartz, Victoria R; Simmons, Quinneil J; Jay, Gregory D; Kobayashi, Leo

    2017-03-01

    A stable and readily accessible work surface for bedside medical procedures represents a valuable tool for acute care providers. In emergency department (ED) settings, the design and implementation of traditional Mayo stands and related surface devices often limit their availability, portability, and usability, which can lead to suboptimal clinical practice conditions that may affect the safe and effective performance of medical procedures and delivery of patient care. We designed and built a novel, open-source, portable, bedside procedural surface through an iterative development process with use testing in simulated and live clinical environments. The procedural surface development project was conducted between October 2014 and June 2016 at an academic referral hospital and its affiliated simulation facility. An interdisciplinary team of emergency physicians, mechanical engineers, medical students, and design students sought to construct a prototype bedside procedural surface out of off-the-shelf hardware during a collaborative university course on health care design. After determination of end-user needs and core design requirements, multiple prototypes were fabricated and iteratively modified, with early variants featuring undermattress stabilizing supports or ratcheting clamp mechanisms. Versions 1 through 4 underwent 2 hands-on usability-testing simulation sessions; version 5 was presented at a design critique held jointly by a panel of clinical and industrial design faculty for expert feedback. Responding to select feedback elements over several surface versions, investigators arrived at a near-final prototype design for fabrication and use testing in a live clinical setting. This experimental procedural surface (version 8) was constructed and then deployed for controlled usability testing against the standard Mayo stands in use at the study site ED. Clinical providers working in the ED who opted to participate in the study were provided with the prototype surface and just-in-time training on its use when performing bedside procedures. Subjects completed the validated 10-point System Usability Scale postshift for the surface that they had used. The study protocol was approved by the institutional review board. Multiple prototypes and recursive design revisions resulted in a fully functional, portable, and durable bedside procedural surface that featured a stainless steel tray and intuitive hook-and-lock mechanisms for attachment to ED stretcher bed rails. Forty-two control and 40 experimental group subjects participated and completed questionnaires. The median System Usability Scale score (out of 100; higher scores associated with better usability) was 72.5 (interquartile range [IQR] 51.3 to 86.3) for the Mayo stand; the experimental surface was scored at 93.8 (IQR 84.4 to 97.5 for a difference in medians of 17.5 (95% confidence interval 10 to 27.5). Subjects reported several usability challenges with the Mayo stand; the experimental surface was reviewed as easy to use, simple, and functional. In accordance with experimental live environment deployment, questionnaire responses, and end-user suggestions, the project team finalized the design specification for the experimental procedural surface for open dissemination. An iterative, interdisciplinary approach was used to generate, evaluate, revise, and finalize the design specification for a new procedural surface that met all core end-user requirements. The final surface design was evaluated favorably on a validated usability tool against Mayo stands when use tested in simulated and live clinical settings. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  16. Studies of the Use of Electrochemical Impedance Spectroscopy to Characterize and Assess the Performance of Lacquers Used to Protect Aluminum Sheet and Can Ends

    NASA Astrophysics Data System (ADS)

    Ali, Mohammad

    This study involved investigating the feasibility of using Electrochemical Impedance Spectroscopy to assess the performance of coatings used to protect aluminum in beverage containers, and developing an accelerated testing procedure. In the preliminary investigation, tests were performed to ensure that the EIS systems at hand are capable, functional and consistent. This was followed by EIS testing of kitchen-aluminum foil and high-impedance epoxy polymer as a baseline for chemically-active and chemically-inert systems. The ability of EIS to differentiate between intact and flawed coatings was tested by investigating deliberately damaged coatings. The effects of varying the pH and oxygen content on the performance of the coated aluminum samples were also tested. From this investigation, it has been concluded that EIS can be used to differentiate between intact and flawed coatings and detect corrosion before it is visually observable. Signatures of corrosion have been recorded and a preliminary testing procedure has been drawn.

  17. 40 CFR 90.708 - Cumulative Sum (CumSum) procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... is 5.0×σ, and is a function of the standard deviation, σ. σ=is the sample standard deviation and is... individual engine. FEL=Family Emission Limit (the standard if no FEL). F=.25×σ. (2) After each test pursuant...

  18. Testing manifest monotonicity using order-constrained statistical inference.

    PubMed

    Tijmstra, Jesper; Hessen, David J; van der Heijden, Peter G M; Sijtsma, Klaas

    2013-01-01

    Most dichotomous item response models share the assumption of latent monotonicity, which states that the probability of a positive response to an item is a nondecreasing function of a latent variable intended to be measured. Latent monotonicity cannot be evaluated directly, but it implies manifest monotonicity across a variety of observed scores, such as the restscore, a single item score, and in some cases the total score. In this study, we show that manifest monotonicity can be tested by means of the order-constrained statistical inference framework. We propose a procedure that uses this framework to determine whether manifest monotonicity should be rejected for specific items. This approach provides a likelihood ratio test for which the p-value can be approximated through simulation. A simulation study is presented that evaluates the Type I error rate and power of the test, and the procedure is applied to empirical data.

  19. Scatter of X-rays on polished surfaces

    NASA Technical Reports Server (NTRS)

    Hasinger, G.

    1981-01-01

    In investigating the dispersion properties of telescope mirrors used in X-ray astronomy, the slight scattering characteristics of X-ray radiation by statistically rough surfaces were examined. The mathematics and geometry of scattering theory are described. The measurement test assembly is described and results of measurements on samples of plane mirrors are given. Measurement results are evaluated. The direct beam, the convolution of the direct beam and the scattering halo, curve fitting by the method of least squares, various autocorrelation functions, results of the fitting procedure for small scattering, and deviations in the kernel of the scattering distribution are presented. A procedure for quality testing of mirror systems through diagnosis of rough surfaces is described.

  20. Visual-Accommodation Trainer/Tester

    NASA Technical Reports Server (NTRS)

    Randle, Robert J., Jr.

    1986-01-01

    Ophthalmic instrument tests and helps develop focusing ability. Movable stage on a fixed base permits adjustment of effective target position as perceived by subject. Various apertures used to perform tests and training procedures. Ophthalmic instrument provides four functions: it measures visual near and far points; provides focus stimulus in vision research; measures visual-accommodation resting position; can be used to train for volitional control of person's focus response.

  1. Conservativeness in Rejection of the Null Hypothesis when Using the Continuity Correction in the MH Chi-Square Test in DIF Applications

    ERIC Educational Resources Information Center

    Paek, Insu

    2010-01-01

    Conservative bias in rejection of a null hypothesis from using the continuity correction in the Mantel-Haenszel (MH) procedure was examined through simulation in a differential item functioning (DIF) investigation context in which statistical testing uses a prespecified level [alpha] for the decision on an item with respect to DIF. The standard MH…

  2. Comparing light sensitivity, linearity and step response of electronic cameras for ophthalmology.

    PubMed

    Kopp, O; Markert, S; Tornow, R P

    2002-01-01

    To develop and test a procedure to measure and compare light sensitivity, linearity and step response of electronic cameras. The pixel value (PV) of digitized images as a function of light intensity (I) was measured. The sensitivity was calculated from the slope of the P(I) function, the linearity was estimated from the correlation coefficient of this function. To measure the step response, a short sequence of images was acquired. During acquisition, a light source was switched on and off using a fast shutter. The resulting PV was calculated for each video field of the sequence. A CCD camera optimized for the near-infrared (IR) spectrum showed the highest sensitivity for both, visible and IR light. There are little differences in linearity. The step response depends on the procedure of integration and read out.

  3. Variability in source sediment contributions by applying different statistic test for a Pyrenean catchment.

    PubMed

    Palazón, L; Navas, A

    2017-06-01

    Information on sediment contribution and transport dynamics from the contributing catchments is needed to develop management plans to tackle environmental problems related with effects of fine sediment as reservoir siltation. In this respect, the fingerprinting technique is an indirect technique known to be valuable and effective for sediment source identification in river catchments. Large variability in sediment delivery was found in previous studies in the Barasona catchment (1509 km 2 , Central Spanish Pyrenees). Simulation results with SWAT and fingerprinting approaches identified badlands and agricultural uses as the main contributors to sediment supply in the reservoir. In this study the <63 μm sediment fraction from the surface reservoir sediments (2 cm) are investigated following the fingerprinting procedure to assess how the use of different statistical procedures affects the amounts of source contributions. Three optimum composite fingerprints were selected to discriminate between source contributions based in land uses/land covers from the same dataset by the application of (1) discriminant function analysis; and its combination (as second step) with (2) Kruskal-Wallis H-test and (3) principal components analysis. Source contribution results were different between assessed options with the greatest differences observed for option using #3, including the two step process: principal components analysis and discriminant function analysis. The characteristics of the solutions by the applied mixing model and the conceptual understanding of the catchment showed that the most reliable solution was achieved using #2, the two step process of Kruskal-Wallis H-test and discriminant function analysis. The assessment showed the importance of the statistical procedure used to define the optimum composite fingerprint for sediment fingerprinting applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. [Effectiveness of a cognitive-motorphysiotherapeutical therapy intervention in institutionalized older adults with mild cognitive impairment and mild dementia].

    PubMed

    Menezes, Alessandra Vieira; Aguiar, Alessandra da Silva de; Alves, Elysama Fernandes; Quadros, Layse Biz de; Bezerra, Poliana Penasso

    2016-11-01

    The aim of this study was to investigate the effectiveness of four months of cognitive-motor physiotherapy intervention, with a single weekly visit, on cognitive function, mobility and functional independence of institutionalized elderly individuals with mild cognitive impairment and mild dementia. In a controlled clinical trial, 15 subjects were allocated to experimental and control groups. Regarding the assessment of the subjects the following instruments were applied: Mini-Mental State Examination, Clinical Dementia Rating Scale, Verbal Fluency Test and Frontal Assessment Battery for analyzing cognitive functions; Berg Balance Scale and Timed Up and Go Test to verify mobility, and; Barthel Scale and Pfeffer Index for measurement of functional independence. The statistical procedures involved the application of Student's t-test with a 5% significance threshold. With respect to the results, the experimental group performed better only in mobility-related tests at the end of the intervention (p < 0.05). The proposed intervention showed efficacy on mobility, but not on cognition and functional independence. The short period of time and low weekly basis may be related to the results obtained.

  5. mfpa: Extension of mfp using the ACD covariate transformation for enhanced parametric multivariable modeling.

    PubMed

    Royston, Patrick; Sauerbrei, Willi

    2016-01-01

    In a recent article, Royston (2015, Stata Journal 15: 275-291) introduced the approximate cumulative distribution (acd) transformation of a continuous covariate x as a route toward modeling a sigmoid relationship between x and an outcome variable. In this article, we extend the approach to multivariable modeling by modifying the standard Stata program mfp. The result is a new program, mfpa, that has all the features of mfp plus the ability to fit a new model for user-selected covariates that we call fp1( p 1 , p 2 ). The fp1( p 1 , p 2 ) model comprises the best-fitting combination of a dimension-one fractional polynomial (fp1) function of x and an fp1 function of acd ( x ). We describe a new model-selection algorithm called function-selection procedure with acd transformation, which uses significance testing to attempt to simplify an fp1( p 1 , p 2 ) model to a submodel, an fp1 or linear model in x or in acd ( x ). The function-selection procedure with acd transformation is related in concept to the fsp (fp function-selection procedure), which is an integral part of mfp and which is used to simplify a dimension-two (fp2) function. We describe the mfpa command and give univariable and multivariable examples with real data to demonstrate its use.

  6. Executive functions deficit in mild cognitive impairment.

    PubMed

    Traykov, Latchezar; Raoux, Nadine; Latour, Florence; Gallo, Livia; Hanon, Olivier; Baudic, Sophie; Bayle, Catherine; Wenisch, Emilie; Remy, Philippe; Rigaud, Anne-Sophie

    2007-12-01

    To investigate whether patients diagnosed with amnestic mild cognitive impairment (MCI) have also impairment in attention/executive functions, and therefore to clarify whether all subcomponents of executive control are equally affected in MCI. MCI refers to the transitional state between normal aging and dementia. Amnestic MCI is characterized by impaired episodic memory, although subtle impairment of executive functions has been noted on neuropsychologic tests. We investigated 20 MCI patients and 20 normal controls using episodic memory, attention/executive functions, language, and praxis tests. MCI patients had significantly lower scores on all measures of the Free and Cued Selective Reminding Test (P<0.05 to 0.01) than controls. Furthermore, MCI had a greater number of perseverations (P<0.01) on Modified Card Sorting Test and the lowest performance on the Stroop Test (P<0.02). Our findings showed impairment in episodic memory performance in MCI as compared with that of controls. In addition, MCI patients had problems with response inhibition, switching, and cognitive flexibility, which encompass various aspects of executive functions. This suggests that MCI may be identified by using a more detailed procedure for the assessment of cognitive decline than the evaluation of memory alone.

  7. Quantitative methods in assessment of neurologic function.

    PubMed

    Potvin, A R; Tourtellotte, W W; Syndulko, K; Potvin, J

    1981-01-01

    Traditionally, neurologists have emphasized qualitative techniques for assessing results of clinical trials. However, in recent years qualitative evaluations have been increasingly augmented by quantitative tests for measuring neurologic functions pertaining to mental state, strength, steadiness, reactions, speed, coordination, sensation, fatigue, gait, station, and simulated activities of daily living. Quantitative tests have long been used by psychologists for evaluating asymptomatic function, assessing human information processing, and predicting proficiency in skilled tasks; however, their methodology has never been directly assessed for validity in a clinical environment. In this report, relevant contributions from the literature on asymptomatic human performance and that on clinical quantitative neurologic function are reviewed and assessed. While emphasis is focused on tests appropriate for evaluating clinical neurologic trials, evaluations of tests for reproducibility, reliability, validity, and examiner training procedures, and for effects of motivation, learning, handedness, age, and sex are also reported and interpreted. Examples of statistical strategies for data analysis, scoring systems, data reduction methods, and data display concepts are presented. Although investigative work still remains to be done, it appears that carefully selected and evaluated tests of sensory and motor function should be an essential factor for evaluating clinical trials in an objective manner.

  8. Concepts in health evaluation of commercial and industrial chemicals

    NASA Technical Reports Server (NTRS)

    Mcnamara, B. P.

    1975-01-01

    A method is described for determining no toxic effect exposure levels based on short-term testing of industrial and commercial chemicals. Procedures for monitoring all organs and body functions for the presence or absence of toxicological effects are demonstrated using various laboratory animals.

  9. Cryptography: Cracking Codes.

    ERIC Educational Resources Information Center

    Myerscough, Don; And Others

    1996-01-01

    Describes an activity whose objectives are to encode and decode messages using linear functions and their inverses; to use modular arithmetic, including use of the reciprocal for simple equation solving; to analyze patterns and make and test conjectures; to communicate procedures and algorithms; and to use problem-solving strategies. (ASK)

  10. Alternative Strategies in Assessing Special Education Needs

    ERIC Educational Resources Information Center

    Dykeman, Bruce F.

    2006-01-01

    The conventional use of standardized testing within a discrepancy analysis model is reviewed. The Response-to-Intervention (RTI) process is explained, along with descriptions of assessment procedures within RTI: functional assessment, authentic assessment, curriculum-based measurement, and play-based assessment. Psychometric issues relevant to RTI…

  11. Higher doses of (+)MK-801 (dizocilpine) induced mortality and procedural but not cognitive deficits in delayed testing in the active place avoidance with reversal on the Carousel.

    PubMed

    Lobellová, V; Brichtová, E; Petrásek, T; Valeš, K; Stuchlík, A

    2015-01-01

    Schizophrenia is a devastating disorder affecting 1 % of the world's population. An important role in the study of this disease is played by animal models. Since there is evidence that acute psychotic episodes can have consequences on later cognitive functioning, the present study has investigated the effects of a single systemic application of higher doses of (+)MK-801 (3 mg/kg and 5 mg/kg) to adult male Long-Evans rats from the Institute's breeding colony on delayed testing in the active place avoidance task with reversal on the Carousel (a rotating arena). Besides significant mortality due to the injections, a disruption of procedural functions in active place avoidance, after the dose 5 mg/kg was observed. It was concluded that Long-Evans rats from our breeding colony do not represent a suitable biomodel for studying the effects of single high-dose NMDA antagonists.

  12. A procedure for scaling sensory attributes based on multidimensional measurements: application to sensory sharpness of kitchen knives

    NASA Astrophysics Data System (ADS)

    Takatsuji, Toshiyuki; Tanaka, Ken-ichi

    1996-06-01

    A procedure is derived by which sensory attributes can be scaled as a function of various physical and/or chemical properties of the object to be tested. This procedure consists of four successive steps: (i) design and experiment, (ii) fabrication of specimens according to the design parameters, (iii) assessment of a sensory attribute using sensory evaluation and (iv) derivation of the relationship between the parameters and the sensory attribute. In these steps an experimental design using orthogonal arrays, analysis of variance and regression analyses are used strategically. When a specimen with the design parameters cannot be physically fabricated, an alternative specimen having parameters closest to the design is selected from a group of specimens which can be physically made. The influence of the deviation of actual parameters from the desired ones is also discussed. A method of confirming the validity of the regression equation is also investigated. The procedure is applied to scale the sensory sharpness of kitchen knives as a function of the edge angle and the roughness of the cutting edge.

  13. Constraining response output on conjunctive fixed-ratio 1 fixed-time reinforcement schedules: Effects on the postreinforcement pause.

    PubMed

    Lopez, F; Pereira, C

    1985-03-01

    Two experiments used response-restriction procedures in order to test the independence of the factors determining response rate and the factors determining the size of the postreinforcement pause on interval schedules. Responding was restricted by response-produced blackout or by retracting the lever. In Experiment 1 with a Conjunctive FR 1 FT schedule, the blackout procedure reduced the postreinforcement pause more than the lever-retraction procedure did, and both procedures produced shorter pauses than did the schedule without response restriction. In Experiment 2 the interreinforcement interval was also manipulated, and the size of the pause was an increasing function of the interreinforcement interval, but the rate of increase was lower than that produced by fixed interval schedules of comparable interval durations. The assumption of functional independence of the postreinforcement pause and terminal rate in fixed interval schedules is questioned since data suggest that pause reductions resulted from constraining variation in response number compared to equivalent periodic schedules in which response number was allowed to vary. Copyright © 1985. Published by Elsevier B.V.

  14. Impairment in Proverb Interpretation as an Executive Function Deficit in Patients with Amnestic Mild Cognitive Impairment and Early Alzheimer's Disease

    PubMed Central

    Leyhe, Thomas; Saur, Ralf; Eschweiler, Gerhard W.; Milian, Monika

    2011-01-01

    Background/Aims Proverb interpretation is assumed to reflect executive functions. We hypothesized that proverb interpretation is impaired in patients with amnestic mild cognitive impairment (aMCI) diagnosed as single-domain impairment by common neuropsychological testing. Methods We compared performance in a proverb interpretation test in single-domain aMCI patients and patients with early Alzheimer's disease (EAD). Results The groups with aMCI and EAD performed significantly worse than healthy controls. Both patient groups gave concrete answers with a similar frequency. However, patients with EAD tended to give senseless answers more frequently. Conclusions Our data suggest that in patients diagnosed as single-domain aMCI, deterioration of executive functions is detectable with subtle and appropriate neuropsychological testing. Implementation of these procedures may improve the early prediction of AD. PMID:22163233

  15. The effect of ursodeoxycholic acid in liver functional restoration of patients with obstructive jaundice after endoscopic treatment: a prospective, randomized, and controlled study.

    PubMed

    Fekaj, Enver; Gjata, Arben; Maxhuni, Mehmet

    2013-09-22

    In patients with obstructive jaundice, multi-organ dysfunction may develop. This trial is a prospective, open-label, randomized, and controlled study with the objective to evaluate the effect of ursodeoxycholic acid in liver functional restoration in patients with obstructive jaundice after endoscopic treatment. The aim of this study is to evaluate the effect of ursodeoxycholic acid in liver functional restoration of patients with obstructive jaundice after endoscopic treatment. The hypothesis of this trial is that patients with obstructive jaundice, in which will be administered UDCA, in the early phase after endoscopic intervention will have better and faster functional restoration of the liver than patients in the control group.Patients with obstructive jaundice, randomly, will be divided into two groups: (A) test group in which will be administered ursodeoxycholic acid twenty-four hours after endoscopic procedure and will last fourteen days, and (B) control group.Serum-testing will include determination of bilirubin, alanine transaminase, aspartate transaminase, gama-glutamil transpeptidase, alkaline phosphatase, albumin, and cholesterol levels. These parameters will be determined one day prior endoscopic procedure, and on the third, fifth, seventh, tenth, twelfth and fourteenth days after endoscopic intervention. This trial is a prospective, open-label, randomized, and controlled study to asses the effect of ursodeoxycholic acid in liver functional restoration of patients with obstructive jaundice in the early phase after endoscopic treatment.

  16. Traceable measurements of the electrical parameters of solid-state lighting products

    NASA Astrophysics Data System (ADS)

    Zhao, D.; Rietveld, G.; Braun, J.-P.; Overney, F.; Lippert, T.; Christensen, A.

    2016-12-01

    In order to perform traceable measurements of the electrical parameters of solid-state lighting (SSL) products, it is necessary to technically adequately define the measurement procedures and to identify the relevant uncertainty sources. The present published written standard for SSL products specifies test conditions, but it lacks an explanation of how adequate these test conditions are. More specifically, both an identification of uncertainty sources and a quantitative uncertainty analysis are absent. This paper fills the related gap in the present written standard. New uncertainty sources with respect to conventional lighting sources are determined and their effects are quantified. It shows that for power measurements, the main uncertainty sources are temperature deviation, power supply voltage distortion, and instability of the SSL product. For current RMS measurements, the influence of bandwidth, shunt resistor, power supply source impedance and ac frequency flatness are significant as well. The measurement uncertainty depends not only on the test equipment but is also a function of the characteristics of the device under test (DUT), for example, current harmonics spectrum and input impedance. Therefore, an online calculation tool is provided to help non-electrical experts. Following our procedures, unrealistic uncertainty estimations, unnecessary procedures and expensive equipment can be prevented.

  17. 40 CFR 600.111-80 - Test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Test procedures. 600.111-80 Section... Model Year Automobiles-Test Procedures § 600.111-80 Test procedures. (a) The test procedures to be...-78 of this chapter, as applicable. (The evaporative and refueling loss portions of the test procedure...

  18. 40 CFR 600.111-93 - Test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Test procedures. 600.111-93 Section... Model Year Automobiles-Test Procedures § 600.111-93 Test procedures. (a) The test procedures to be... loss portion of the test procedure may be omitted unless specifically required by the Administrator...

  19. An automatic identification procedure to promote the use of FES-cycling training for hemiparetic patients.

    PubMed

    Ambrosini, Emilia; Ferrante, Simona; Schauer, Thomas; Ferrigno, Giancarlo; Molteni, Franco; Pedrocchi, Alessandra

    2014-01-01

    Cycling induced by Functional Electrical Stimulation (FES) training currently requires a manual setting of different parameters, which is a time-consuming and scarcely repeatable procedure. We proposed an automatic procedure for setting session-specific parameters optimized for hemiparetic patients. This procedure consisted of the identification of the stimulation strategy as the angular ranges during which FES drove the motion, the comparison between the identified strategy and the physiological muscular activation strategy, and the setting of the pulse amplitude and duration of each stimulated muscle. Preliminary trials on 10 healthy volunteers helped define the procedure. Feasibility tests on 8 hemiparetic patients (5 stroke, 3 traumatic brain injury) were performed. The procedure maximized the motor output within the tolerance constraint, identified a biomimetic strategy in 6 patients, and always lasted less than 5 minutes. Its reasonable duration and automatic nature make the procedure usable at the beginning of every training session, potentially enhancing the performance of FES-cycling training.

  20. 105KE Basin Area Radiation Monitor System (ARMS) Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KINKEL, C.C.

    1999-12-14

    This procedure is intended for the Area Radiation Monitoring System, ARMS, that is replacing the existing Programmable Input-Output Processing System, PIOPS, radiation monitoring system in the 105KE basin. The new system will be referred to as the 105KE ARMS, 105KE Area Radiation Monitoring System. This ATP will ensure calibration integrity of the 105KE radiation detector loops. Also, this ATP will test and document the display, printing, alarm output, alarm acknowledgement, upscale check, and security functions. This ATP test is to be performed after completion of the 105KE ARMS installation. The alarm outputs of the 105KE ARMS will be connected tomore » the basin detector alarms, basin annunciator system, and security Alarm Monitoring System, AMS, located in the 200 area Central Alarm Station (CAS).« less

  1. Type testing the Model 6600 plus automatic TLD reader.

    PubMed

    Velbeck, K J; Luo, L Z; Streetz, K L

    2006-01-01

    The Harshaw Model 6600 Plus is a reader with a capacity for 200 TLD cards or 800 extremity cards. The new unit integrates more functionality, and significantly automates the QC and calibration process compared to the Model 6600. The Model 6600 Plus was tested against the IEC 61066 (1991-2012) procedures using Harshaw TLD-700H and TLD-600H, LiF:Mg,Cu,P based TLD Cards. An overview of the type testing procedures is presented. These include batch homogeneity, detection threshold, reproducibility, linearity, self-irradiation, residue, light effects on dosemeter, light leakage to reader, voltage and frequency, dropping and reader stability. The new TLD reader was found to meet all the IEC criteria by large margins and appears well suited for whole body, extremity and environmental dosimetry applications, with a high degree of dosimetric performance.

  2. Vibration and noise analysis of a gear transmission system

    NASA Technical Reports Server (NTRS)

    Choy, F. K.; Qian, W.; Zakrajsek, J. J.; Oswald, F. B.

    1993-01-01

    This paper presents a comprehensive procedure to predict both the vibration and noise generated by a gear transmission system under normal operating conditions. The gearbox vibrations were obtained from both numerical simulation and experimental studies using a gear noise test rig. In addition, the noise generated by the gearbox vibrations was recorded during the experimental testing. A numerical method was used to develop linear relationships between the gearbox vibration and the generated noise. The hypercoherence function is introduced to correlate the nonlinear relationship between the fundamental noise frequency and its harmonics. A numerical procedure was developed using both the linear and nonlinear relationships generated from the experimental data to predict noise resulting from the gearbox vibrations. The application of this methodology is demonstrated by comparing the numerical and experimental results from the gear noise test rig.

  3. Health maintenance facility: Dental equipment requirements

    NASA Technical Reports Server (NTRS)

    Young, John; Gosbee, John; Billica, Roger

    1991-01-01

    The objectives were to test the effectiveness of the Health Maintenance Facility (HMF) dental suction/particle containment system, which controls fluids and debris generated during simulated dental treatment, in microgravity; to test the effectiveness of fiber optic intraoral lighting systems in microgravity, while simulating dental treatment; and to evaluate the operation and function of off-the-shelf dental handheld instruments, namely a portable dental hand drill and temporary filling material, in microgravity. A description of test procedures, including test set-up, flight equipment, and the data acquisition system, is given.

  4. Laboratory testing of a supercritical helium pump for a magnetic refrigerator

    NASA Technical Reports Server (NTRS)

    Wang, Pao-Lien

    1988-01-01

    A supercritical helium testing system for a magnetic refrigerator has been built. Details of the supercritical helium pump, the test system, and the test instrumentation are given. Actual pump tests were not run during this ASEE term because of delivery problems associated with the required pump flow meter. Consequently, efforts were directed on preliminary design of the magnetic refrigeration system for the pump. The first concern with the magnetic refrigerator design was determining how to effectively make use of the pump. A method to incorporate the supercritical helium pump into a magnetic refrigerator was determined by using a computer model. An illustrated example of this procedure is given to provide a tool for sizing the magnetic refrigerator system as a function of the pump size. The function of the computer model and its operation are also outlined and discussed.

  5. 40 CFR 600.111-08 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Test procedures. 600.111-08 Section... Emission Test Procedures § 600.111-08 Test procedures. This section describes test procedures for the FTP, highway fuel economy test (HFET), US06, SC03, and the cold temperature FTP tests. Perform testing...

  6. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Carpenter, K. H.

    1974-01-01

    The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.

  7. 13C Methacetin Breath Test for Assessment of Microsomal Liver Function: Methodology and Clinical Application.

    PubMed

    Gorowska-Kowolik, Katarzyna; Chobot, Agata; Kwiecien, Jaroslaw

    2017-01-01

    Assessment of the liver function, and the need of constant monitoring of the organ's capacity, concerns not only patients with primary liver diseases, but also those at risk of hepatopathies secondary to other chronic diseases. Most commonly, the diagnostics is based on measurements of static biochemical parameters, which allow us to draw conclusions only indirectly about the function and the degree of damage of the organ. On the other hand, liver biopsy is an invasive procedure and therefore it is associated with a considerable risk of complications. Dynamic tests enable us to assess quantitatively the organ's functional reserve by analyzing the kinetics of the metabolization of the substrate by the liver. In practice applied are breath tests using substances such as aminopyrine, caffeine, methacetin, erythromycin (for assessment of the microsomal function); phenylalanine, galactose (for assessment of the cytosolic function); methionine, octanoate, ketoisocaproic acid (for assessment of the mitochondrial function). The test with 13 C methacetin belongs to the best described and most widely applied methods in noninvasive liver function assessment. Due to the rising availability of this method, knowledge concerning its limitations and controversies regarding the methodology, as well as its usefulness in chosen groups of patients, seems to be vital.

  8. 8s, a numerical simulator of the challenging optical calibration of the E-ELT adaptive mirror M4

    NASA Astrophysics Data System (ADS)

    Briguglio, Runa; Pariani, Giorgio; Xompero, Marco; Riccardi, Armando; Tintori, Matteo; Lazzarini, Paolo; Spanò, Paolo

    2016-07-01

    8s stands for Optical Test TOwer Simulator (with 8 read as in italian 'otto'): it is a simulation tool for the optical calibration of the E-ELT deformable mirror M4 on its test facility. It has been developed to identify possible criticalities in the procedure, evaluate the solutions and estimate the sensitivity to environmental noise. The simulation system is composed by the finite elements model of the tower, the analytic influence functions of the actuators, the ray tracing propagation of the laser beam through the optical surfaces. The tool delivers simulated phasemaps of M4, associated with the current system status: actuator commands, optics alignment and position, beam vignetting, bench temperature and vibrations. It is possible to simulate a single step of the optical test of M4 by changing the system parameters according to a calibration procedure and collect the associated phasemap for performance evaluation. In this paper we will describe the simulation package and outline the proposed calibration procedure of M4.

  9. A Procedural Electroencephalogram Simulator for Evaluation of Anesthesia Monitors.

    PubMed

    Petersen, Christian Leth; Görges, Matthias; Massey, Roslyn; Dumont, Guy Albert; Ansermino, J Mark

    2016-11-01

    Recent research and advances in the automation of anesthesia are driving the need to better understand electroencephalogram (EEG)-based anesthesia end points and to test the performance of anesthesia monitors. This effort is currently limited by the need to collect raw EEG data directly from patients. A procedural method to synthesize EEG signals was implemented in a mobile software application. The application is capable of sending the simulated signal to an anesthesia depth of hypnosis monitor. Systematic sweeps of the simulator generate functional monitor response profiles reminiscent of how network analyzers are used to test electronic components. Three commercial anesthesia monitors (Entropy, NeuroSENSE, and BIS) were compared with this new technology, and significant response and feature variations between the monitor models were observed; this includes reproducible, nonmonotonic apparent multistate behavior and significant hysteresis at light levels of anesthesia. Anesthesia monitor response to a procedural simulator can reveal significant differences in internal signal processing algorithms. The ability to synthesize EEG signals at different anesthetic depths potentially provides a new method for systematically testing EEG-based monitors and automated anesthesia systems with all sensor hardware fully operational before human trials.

  10. Statistical analysis of particle trajectories in living cells

    NASA Astrophysics Data System (ADS)

    Briane, Vincent; Kervrann, Charles; Vimond, Myriam

    2018-06-01

    Recent advances in molecular biology and fluorescence microscopy imaging have made possible the inference of the dynamics of molecules in living cells. Such inference allows us to understand and determine the organization and function of the cell. The trajectories of particles (e.g., biomolecules) in living cells, computed with the help of object tracking methods, can be modeled with diffusion processes. Three types of diffusion are considered: (i) free diffusion, (ii) subdiffusion, and (iii) superdiffusion. The mean-square displacement (MSD) is generally used to discriminate the three types of particle dynamics. We propose here a nonparametric three-decision test as an alternative to the MSD method. The rejection of the null hypothesis, i.e., free diffusion, is accompanied by claims of the direction of the alternative (subdiffusion or superdiffusion). We study the asymptotic behavior of the test statistic under the null hypothesis and under parametric alternatives which are currently considered in the biophysics literature. In addition, we adapt the multiple-testing procedure of Benjamini and Hochberg to fit with the three-decision-test setting, in order to apply the test procedure to a collection of independent trajectories. The performance of our procedure is much better than the MSD method as confirmed by Monte Carlo experiments. The method is demonstrated on real data sets corresponding to protein dynamics observed in fluorescence microscopy.

  11. Thyroid and parathyroid imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandler, M.P.; Patton, J.A.; Partain, C.L.

    1986-01-01

    This book describes the numerous modalities currently used in the diagnosis and treatment of both thyroid and parathyroid disorders. Each modality is fully explained and then evaluated in terms of benefits and limitations in the clinical context. Contents: Production and Quality Control of Radiopharmaceutics Used for Diagnosis and Therapy in Thyroid and Parathyroid Disorders. Basic Physics. Nuclear Instrumentation. Radioimmunoassay: Thyroid Function Tests. Quality Control. Embryology, Anatomy, Physiology, and Thyroid Function Studies. Scintigraphic Thyroid Imaging. Neonatal and Pediatric Thyroid Imaging. Radioiodine Thyroid Uptake Measurement. Radioiodine Treatment of Thyroid Disorders. Radiation Dosimetry of Diagnostic Procedures. Radiation Safety Procedures for High-Level I-131 Therapies.more » X-Ray Fluorescent Scanning. Thyroid Sonography. Computed Tomography in Thyroid Disease. Magnetic Resonance Imaging in Thyroid Disease. Parathyroid Imaging.« less

  12. 40 CFR 1033.315 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Test procedures. 1033.315 Section 1033... Programs § 1033.315 Test procedures. (a) Test procedures. Use the test procedures described in subpart F of this part, except as specified in this section. (1) You may ask to use other test procedures. We will...

  13. 40 CFR 1033.315 - Test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Test procedures. 1033.315 Section 1033... Programs § 1033.315 Test procedures. (a) Test procedures. Use the test procedures described in subpart F of this part, except as specified in this section. (1) You may ask to use other test procedures. We will...

  14. 40 CFR 1033.315 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Test procedures. 1033.315 Section 1033... Programs § 1033.315 Test procedures. (a) Test procedures. Use the test procedures described in subpart F of this part, except as specified in this section. (1) You may ask to use other test procedures. We will...

  15. The Function Acquisition Speed Test (FAST): A Behavior Analytic Implicit Test for Assessing Stimulus Relations

    ERIC Educational Resources Information Center

    O'Reilly, Anthony; Roche, Bryan; Ruiz, Maria; Tyndall, Ian; Gavin, Amanda

    2012-01-01

    Subjects completed a baseline stimulus matching procedure designed to produce two symmetrical stimulus relations; A1-B1 and A2-B2. Using A1, B1, and two novel stimuli, subjects were then trained to produce a common key-press response for two stimuli and a second key-press response for two further stimuli across two blocks of response training.…

  16. On testing an unspecified function through a linear mixed effects model with multiple variance components

    PubMed Central

    Wang, Yuanjia; Chen, Huaihou

    2012-01-01

    Summary We examine a generalized F-test of a nonparametric function through penalized splines and a linear mixed effects model representation. With a mixed effects model representation of penalized splines, we imbed the test of an unspecified function into a test of some fixed effects and a variance component in a linear mixed effects model with nuisance variance components under the null. The procedure can be used to test a nonparametric function or varying-coefficient with clustered data, compare two spline functions, test the significance of an unspecified function in an additive model with multiple components, and test a row or a column effect in a two-way analysis of variance model. Through a spectral decomposition of the residual sum of squares, we provide a fast algorithm for computing the null distribution of the test, which significantly improves the computational efficiency over bootstrap. The spectral representation reveals a connection between the likelihood ratio test (LRT) in a multiple variance components model and a single component model. We examine our methods through simulations, where we show that the power of the generalized F-test may be higher than the LRT, depending on the hypothesis of interest and the true model under the alternative. We apply these methods to compute the genome-wide critical value and p-value of a genetic association test in a genome-wide association study (GWAS), where the usual bootstrap is computationally intensive (up to 108 simulations) and asymptotic approximation may be unreliable and conservative. PMID:23020801

  17. On testing an unspecified function through a linear mixed effects model with multiple variance components.

    PubMed

    Wang, Yuanjia; Chen, Huaihou

    2012-12-01

    We examine a generalized F-test of a nonparametric function through penalized splines and a linear mixed effects model representation. With a mixed effects model representation of penalized splines, we imbed the test of an unspecified function into a test of some fixed effects and a variance component in a linear mixed effects model with nuisance variance components under the null. The procedure can be used to test a nonparametric function or varying-coefficient with clustered data, compare two spline functions, test the significance of an unspecified function in an additive model with multiple components, and test a row or a column effect in a two-way analysis of variance model. Through a spectral decomposition of the residual sum of squares, we provide a fast algorithm for computing the null distribution of the test, which significantly improves the computational efficiency over bootstrap. The spectral representation reveals a connection between the likelihood ratio test (LRT) in a multiple variance components model and a single component model. We examine our methods through simulations, where we show that the power of the generalized F-test may be higher than the LRT, depending on the hypothesis of interest and the true model under the alternative. We apply these methods to compute the genome-wide critical value and p-value of a genetic association test in a genome-wide association study (GWAS), where the usual bootstrap is computationally intensive (up to 10(8) simulations) and asymptotic approximation may be unreliable and conservative. © 2012, The International Biometric Society.

  18. Internal quality control: planning and implementation strategies.

    PubMed

    Westgard, James O

    2003-11-01

    The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.

  19. Profile local linear estimation of generalized semiparametric regression model for longitudinal data.

    PubMed

    Sun, Yanqing; Sun, Liuquan; Zhou, Jie

    2013-07-01

    This paper studies the generalized semiparametric regression model for longitudinal data where the covariate effects are constant for some and time-varying for others. Different link functions can be used to allow more flexible modelling of longitudinal data. The nonparametric components of the model are estimated using a local linear estimating equation and the parametric components are estimated through a profile estimating function. The method automatically adjusts for heterogeneity of sampling times, allowing the sampling strategy to depend on the past sampling history as well as possibly time-dependent covariates without specifically model such dependence. A [Formula: see text]-fold cross-validation bandwidth selection is proposed as a working tool for locating an appropriate bandwidth. A criteria for selecting the link function is proposed to provide better fit of the data. Large sample properties of the proposed estimators are investigated. Large sample pointwise and simultaneous confidence intervals for the regression coefficients are constructed. Formal hypothesis testing procedures are proposed to check for the covariate effects and whether the effects are time-varying. A simulation study is conducted to examine the finite sample performances of the proposed estimation and hypothesis testing procedures. The methods are illustrated with a data example.

  20. Functional analysis screening for multiple topographies of problem behavior.

    PubMed

    Bell, Marlesha C; Fahmie, Tara A

    2018-04-23

    The current study evaluated a screening procedure for multiple topographies of problem behavior in the context of an ongoing functional analysis. Experimenters analyzed the function of a topography of primary concern while collecting data on topographies of secondary concern. We used visual analysis to predict the function of secondary topographies and a subsequent functional analysis to test those predictions. Results showed that a general function was accurately predicted for five of six (83%) secondary topographies. A specific function was predicted and supported for a subset of these topographies. The experimenters discuss the implication of these results for clinicians who have limited time for functional assessment. © 2018 Society for the Experimental Analysis of Behavior.

  1. 10 CFR Appendix A to Part 851 - Worker Safety and Health Functional Areas

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... requirements to research and development laboratory type operations consistent with the DOE level of protection... safety policies and procedures to ensure that pressure systems are designed, fabricated, tested... must include the following: (1) Design drawings, sketches, and calculations must be reviewed and...

  2. 10 CFR Appendix A to Part 851 - Worker Safety and Health Functional Areas

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... requirements to research and development laboratory type operations consistent with the DOE level of protection... safety policies and procedures to ensure that pressure systems are designed, fabricated, tested... must include the following: (1) Design drawings, sketches, and calculations must be reviewed and...

  3. 10 CFR Appendix A to Part 851 - Worker Safety and Health Functional Areas

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... requirements to research and development laboratory type operations consistent with the DOE level of protection... safety policies and procedures to ensure that pressure systems are designed, fabricated, tested... must include the following: (1) Design drawings, sketches, and calculations must be reviewed and...

  4. Connected commercial vehicles — retrofit safety device kit project : safety applications performance and functional test plan and procedure.

    DOT National Transportation Integrated Search

    2014-03-01

    Connected vehicle wireless data communications can enable safety applications that may reduce injuries and fatalities. Cooperative vehicle-to-vehicle (V2V) safety applications will be effective only if a high fraction of vehicles are equipped. Deploy...

  5. 40 CFR 600.111-08 - Test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Test procedures. 600.111-08 Section... Emission Test Procedures § 600.111-08 Test procedures. This section provides test procedures for the FTP, highway, US06, SC03, and the cold temperature FTP tests. Testing shall be performed according to test...

  6. Image-Based Patient-Specific Ventricle Models with Fluid-Structure Interaction for Cardiac Function Assessment and Surgical Design Optimization

    PubMed Central

    Tang, Dalin; Yang, Chun; Geva, Tal; del Nido, Pedro J.

    2010-01-01

    Recent advances in medical imaging technology and computational modeling techniques are making it possible that patient-specific computational ventricle models be constructed and used to test surgical hypotheses and replace empirical and often risky clinical experimentation to examine the efficiency and suitability of various reconstructive procedures in diseased hearts. In this paper, we provide a brief review on recent development in ventricle modeling and its potential application in surgical planning and management of tetralogy of Fallot (ToF) patients. Aspects of data acquisition, model selection and construction, tissue material properties, ventricle layer structure and tissue fiber orientations, pressure condition, model validation and virtual surgery procedures (changing patient-specific ventricle data and perform computer simulation) were reviewed. Results from a case study using patient-specific cardiac magnetic resonance (CMR) imaging and right/left ventricle and patch (RV/LV/Patch) combination model with fluid-structure interactions (FSI) were reported. The models were used to evaluate and optimize human pulmonary valve replacement/insertion (PVR) surgical procedure and patch design and test a surgical hypothesis that PVR with small patch and aggressive scar tissue trimming in PVR surgery may lead to improved recovery of RV function and reduced stress/strain conditions in the patch area. PMID:21344066

  7. Cognitive Function Before and After Left Heart Catheterization.

    PubMed

    Scott, David A; Evered, Lisbeth; Maruff, Paul; MacIsaac, Andrew; Maher, Sarah; Silbert, Brendan S

    2018-03-10

    Hospital procedures have been associated with cognitive change in older patients. This study aimed to document the prevalence of mild cognitive impairment in individuals undergoing left heart catheterization (LHC) before the procedure and the incidence of cognitive decline to 3 months afterwards. We conducted a prospective, observational, clinical investigation of elderly participants undergoing elective LHC. Cognition was assessed using a battery of written tests and a computerized cognitive battery before the LHC and then at 3 months afterwards. The computerized tests were also administered at 24 hours (or discharge) and 7 days after LHC. A control group of 51 community participants was recruited to calculate cognitive decline using the Reliable Change Index. Of 437 participants, mild cognitive impairment was identified in 226 (51.7%) before the procedure. Computerized tests detected an incidence of cognitive decline of 10.0% at 24 hours and 7.5% at 7 days. At 3 months, written tests detected an incidence of cognitive decline of 13.1% and computerized tests detected an incidence of 8.5%. Cognitive decline at 3 months using written tests was associated with increasing age, whereas computerized tests showed cognitive decline was associated with baseline amnestic mild cognitive impairment, diabetes mellitus, and prior coronary stenting. More than half the patients aged >60 years presenting for LHC have mild cognitive impairment. LHC is followed by cognitive decline in 8% to 13% of individuals at 3 months after the procedure. Subtle cognitive decline both before and after LHC is common and may have important clinical implications. URL: www.anzctr.org.au. Unique identifier: ACTRN12607000051448. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  8. 40 CFR 600.111-08 - Test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Test procedures. 600.111-08 Section... Model Year Automobiles-Test Procedures § 600.111-08 Test procedures. This section provides test procedures for the FTP, highway, US06, SC03, and the cold temperature FTP tests. Testing shall be performed...

  9. The optimal power puzzle: scrutiny of the monotone likelihood ratio assumption in multiple testing.

    PubMed

    Cao, Hongyuan; Sun, Wenguang; Kosorok, Michael R

    2013-01-01

    In single hypothesis testing, power is a non-decreasing function of type I error rate; hence it is desirable to test at the nominal level exactly to achieve optimal power. The puzzle lies in the fact that for multiple testing, under the false discovery rate paradigm, such a monotonic relationship may not hold. In particular, exact false discovery rate control may lead to a less powerful testing procedure if a test statistic fails to fulfil the monotone likelihood ratio condition. In this article, we identify different scenarios wherein the condition fails and give caveats for conducting multiple testing in practical settings.

  10. Validating Coherence Measurements Using Aligned and Unaligned Coherence Functions

    NASA Technical Reports Server (NTRS)

    Miles, Jeffrey Hilton

    2006-01-01

    This paper describes a novel approach based on the use of coherence functions and statistical theory for sensor validation in a harsh environment. By the use of aligned and unaligned coherence functions and statistical theory one can test for sensor degradation, total sensor failure or changes in the signal. This advanced diagnostic approach and the novel data processing methodology discussed provides a single number that conveys this information. This number as calculated with standard statistical procedures for comparing the means of two distributions is compared with results obtained using Yuen's robust statistical method to create confidence intervals. Examination of experimental data from Kulite pressure transducers mounted in a Pratt & Whitney PW4098 combustor using spectrum analysis methods on aligned and unaligned time histories has verified the effectiveness of the proposed method. All the procedures produce good results which demonstrates how robust the technique is.

  11. Development and characterization of a pre-treatment procedure to eliminate human monoclonal antibody therapeutic drug and matrix interference in cell-based functional neutralizing antibody assays.

    PubMed

    Xu, Weifeng; Jiang, Hao; Titsch, Craig; Haulenbeek, Jonathan R; Pillutla, Renuka C; Aubry, Anne-Françoise; DeSilva, Binodh S; Arnold, Mark E; Zeng, Jianing; Dodge, Robert W

    2015-01-01

    Biological therapeutics can induce an undesirable immune response resulting in the formation of anti-drug antibodies (ADA), including neutralizing antibodies (NAbs). Functional (usually cell-based) NAb assays are preferred to determine NAb presence in patient serum, but are often subject to interferences from numerous serum factors, such as growth factors and disease-related cytokines. Many functional cell-based NAb assays are essentially drug concentration assays that imply the presence of NAbs by the detection of small changes in functional drug concentration. Any drug contained in the test sample will increase the total amount of drug in the assay, thus reducing the sensitivity of NAb detection. Biotin-drug Extraction with Acid Dissociation (BEAD) has been successfully applied to extract ADA, thereby removing drug and other interfering factors from human serum samples. However, to date there has been no report to estimate the residual drug level after BEAD treatment when the drug itself is a human monoclonal antibody; mainly due to the limitation of traditional ligand-binding assays. Here we describe a universal BEAD optimization procedure for human monoclonal antibody (mAb) drugs by using a LC-MS/MS method to simultaneously measure drug (a mutant human IgG4), NAb positive control (a mouse IgG), and endogenous human IgGs as an indicator of nonspecific carry-over in the BEAD eluate. This is the first report demonstrating that residual human mAb drug level in clinical sample can be measured after BEAD pre-treatment, which is critical for further BEAD procedure optimization and downstream immunogenicity testing. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Performance optimization of helicopter rotor blades

    NASA Technical Reports Server (NTRS)

    Walsh, Joanne L.

    1991-01-01

    As part of a center-wide activity at NASA Langley Research Center to develop multidisciplinary design procedures by accounting for discipline interactions, a performance design optimization procedure is developed. The procedure optimizes the aerodynamic performance of rotor blades by selecting the point of taper initiation, root chord, taper ratio, and maximum twist which minimize hover horsepower while not degrading forward flight performance. The procedure uses HOVT (a strip theory momentum analysis) to compute the horse power required for hover and the comprehensive helicopter analysis program CAMRAD to compute the horsepower required for forward flight and maneuver. The optimization algorithm consists of the general purpose optimization program CONMIN and approximate analyses. Sensitivity analyses consisting of derivatives of the objective function and constraints are carried out by forward finite differences. The procedure is applied to a test problem which is an analytical model of a wind tunnel model of a utility rotor blade.

  13. Comparing preference assessments: selection- versus duration-based preference assessment procedures.

    PubMed

    Kodak, Tiffany; Fisher, Wayne W; Kelley, Michael E; Kisamore, April

    2009-01-01

    In the current investigation, the results of a selection- and a duration-based preference assessment procedure were compared. A Multiple Stimulus With Replacement (MSW) preference assessment [Windsor, J., Piché, L. M., & Locke, P. A. (1994). Preference testing: A comparison of two presentation methods. Research in Developmental Disabilities, 15, 439-455] and a variation of a Free-Operant (FO) preference assessment procedure [Roane, H. S., Vollmer, T. R., Ringdahl, J. E., & Marcus, B. A. (1998). Evaluation of a brief stimulus preference assessment. Journal of Applied Behavior Analysis, 31, 605-620] were conducted with four participants. A reinforcer assessment was conducted to determine which preference assessment procedure identified the item that produced the highest rates of responding. The items identified as most highly preferred were different across preference assessment procedures for all participants. Results of the reinforcer assessment showed that the MSW identified the item that functioned as the most effective reinforcer for two participants.

  14. FGWAS: Functional genome wide association analysis.

    PubMed

    Huang, Chao; Thompson, Paul; Wang, Yalin; Yu, Yang; Zhang, Jingwen; Kong, Dehan; Colen, Rivka R; Knickmeyer, Rebecca C; Zhu, Hongtu

    2017-10-01

    Functional phenotypes (e.g., subcortical surface representation), which commonly arise in imaging genetic studies, have been used to detect putative genes for complexly inherited neuropsychiatric and neurodegenerative disorders. However, existing statistical methods largely ignore the functional features (e.g., functional smoothness and correlation). The aim of this paper is to develop a functional genome-wide association analysis (FGWAS) framework to efficiently carry out whole-genome analyses of functional phenotypes. FGWAS consists of three components: a multivariate varying coefficient model, a global sure independence screening procedure, and a test procedure. Compared with the standard multivariate regression model, the multivariate varying coefficient model explicitly models the functional features of functional phenotypes through the integration of smooth coefficient functions and functional principal component analysis. Statistically, compared with existing methods for genome-wide association studies (GWAS), FGWAS can substantially boost the detection power for discovering important genetic variants influencing brain structure and function. Simulation studies show that FGWAS outperforms existing GWAS methods for searching sparse signals in an extremely large search space, while controlling for the family-wise error rate. We have successfully applied FGWAS to large-scale analysis of data from the Alzheimer's Disease Neuroimaging Initiative for 708 subjects, 30,000 vertices on the left and right hippocampal surfaces, and 501,584 SNPs. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Improving the Sandia Test Protocols with Advanced Inverter Functionality Testing of INV3, VV11, FW21, and L/HVRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Dean

    2013-11-01

    Sandia National Laboratories has created a test protocol for IEC TR 61850-90-7 advanced distributed energy resource (DER) functions, titled "Test Protocols for Advanced Inverter Interoperability Functions," often referred to as the Sandia Test Protocols. This document is currently in draft form, but has been shared with stakeholders around the world with the ultimate goal of collaborating to create a consensus set of test protocols which can be then incorporated into an International Electrotechnical Commission (IEC) and/or Underwriters Laboratories (UL) certification standard. The protocols are designed to ensure functional interoperability of DER (primarily photovoltaic (PV) inverters and energy storage systems) asmore » specified by the IEC technical report through communication and electrical tests. In this report, Sandia exercises the electrical characterization portion of the test protocols for four functions: constant power factor (INV3), volt-var (VV11), frequency-watt (FW21), and Low and High Voltage Ride Through (L/HVRT). The goal of the tests reported here was not to characterize the performance of the equipment under test (EUT), but rather to (a) exercise the draft Sandia Test Protocols in order to identify any revisions needed in test procedures, conditions, or equipment and (b) gain experience with state-of-the-art DER equipment to determine if the tests put unrealistic or overly aggressive requirements on EUT operation. In performing the work according to the current versions of the protocols, Sandia was able to identify weaknesses in the current versions and suggest improvements to the test protocols.« less

  16. Estimation of the Operating Characteristics When the Test Information of the Old Test Is Not Constant. II. Simple Sum Procedure of the Conditional P.D.F. Approach/Normal Approach Method Using Three Subtests of the Old Test, Number 2

    DTIC Science & Technology

    1981-07-01

    Samejima, RR-79-1), suggests that it will be more fruitful to observe the square root of an information function, rather than the information...II44 t&4 ~4J44 AJ.ISN.a -64- 0I 44 0- -J- .00 c;i 0* 0 cIJ II Ys c0 r.M A.LISN30 -65- IV-8 the estimated density functions, g*(r*) , will affect the...Yukihiro NoguchiFaculty of Education Department of Psychology University of Tokyo Elliot Hall Bongo , Bumkyoku 75 East River Road Tokyo, Japan ŕ

  17. REFLEX MODIFICATION: AN APPROACH TO INCORPORATE INTO A DEVELOPMENTAL NEUROTOXICITY (DNT) STUDY DESIGN WITH COMMERCIAL EQUIPMENT.

    EPA Science Inventory

    Reflex modification (RM) of the startle response is a very useful tool for testing sensory function and the integrity of a well-defined complement of neural circuits. Advantages of this procedure include the ability to rapidly acquire objective measurements and differentiate sen...

  18. Liquid rocket valve assemblies

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design and operating characteristics of valve assemblies used in liquid propellant rocket engines are discussed. The subjects considered are as follows: (1) valve selection parameters, (2) major design aspects, (3) design integration of valve subassemblies, and (4) assembly of components and functional tests. Information is provided on engine, stage, and spacecraft checkout procedures.

  19. Possible alternative to European Pharmacopoeia's method of analysis Test for Fc Function of Immunoglobulin (2.7.9) by using tetanus toxoid as antigen.

    PubMed

    Perez-del-Pulgar, S; Lopez, M; Gensana, M; Jorquera, J I

    2006-08-01

    Preparations of intravenous immunoglobulins must keep functional integrity throughout the purification process. In order to assess Fc fragment functionality, the European Pharmacopoeia proposes the Test for Fc function of immunoglobulin (2.7.9), which is based on a rubella antigen of high titre. Sometimes, such antigen is difficult to obtain. In the present study, we develop the same assay using tetanus toxoid instead of rubella antigen, adapting the procedure for the use of tetanus toxoid. The comparison between rubella-based and tetanus-based assays showed that the slopes of the haemolysis curves were higher if red blood cells had been sensitised with the rubella antigen than with tetanus toxoid. Nonetheless, the tetanus-based assay gave satisfactory results and it could be a good alternative antigen target.

  20. A Bayesian approach to parameter and reliability estimation in the Poisson distribution.

    NASA Technical Reports Server (NTRS)

    Canavos, G. C.

    1972-01-01

    For life testing procedures, a Bayesian analysis is developed with respect to a random intensity parameter in the Poisson distribution. Bayes estimators are derived for the Poisson parameter and the reliability function based on uniform and gamma prior distributions of that parameter. A Monte Carlo procedure is implemented to make possible an empirical mean-squared error comparison between Bayes and existing minimum variance unbiased, as well as maximum likelihood, estimators. As expected, the Bayes estimators have mean-squared errors that are appreciably smaller than those of the other two.

  1. An evaluation of the hemiplegic subject based on the Bobath approach. Part III. A validation study.

    PubMed

    Arsenault, A B; Dutil, E; Lambert, J; Corriveau, H; Guarna, F; Drouin, G

    1988-01-01

    Sixty-two hemiplegic subjects were treated with the Bobath approach for a period of three months. During this time they were evaluated on three occasions. The testing battery consisted of a Bobath evaluation, the Brunnstrom scale, the Fugl-Meyer test, the Upper Extremity Functional Test (UEFT) and the Present Pain Intensity (PPI) of the McGill pain questionnaire. A Friedman analysis of variance showed that, except for pain, all the protocols used disclosed significant progress (p less than 0.001) over time in terms of motor recovery. Except for pain, the results of the Bobath evaluation were significantly correlated (Spearman's Rho, p less than 0.001) with the results of the other testing procedures. It is concluded that the new Bobath evaluation proposed in a previous paper is as sensitive in depicting progress in motor recovery over time as are the other testing procedures used. Furthermore, this new evaluation seems to be measuring similar properties to the other tests. However, pain (PPI) appears not to be an important dependent variable.

  2. Operation and performance of the Ciba-Corning 512 coagulation monitor during parabolic flight

    NASA Technical Reports Server (NTRS)

    Gocke, Robyn; Lloyd, Charles W.; Greenthaner, Nancy K.

    1991-01-01

    The goal was to assess the functionality and evaluate the procedures and operations required to operate the Ciba-Corning 512 Coagulation Monitor during parabolic flight. This monitor determines the clotting characteristics of blood. The analyzer operates by laser detection of the cessation of blood flow in a capillary channel within a test cartridge. Test simulator results were excellent for both pre-and post-flight. In-flight results were not obtained due to the warm-up time required for the simulator. Since this is an electronic function only, the expected results on the simulator would be the same in zero-g.

  3. Random analysis of bearing capacity of square footing using the LAS procedure

    NASA Astrophysics Data System (ADS)

    Kawa, Marek; Puła, Wojciech; Suska, Michał

    2016-09-01

    In the present paper, a three-dimensional problem of bearing capacity of square footing on random soil medium is analyzed. The random fields of strength parameters c and φ are generated using LAS procedure (Local Average Subdivision, Fenton and Vanmarcke 1990). The procedure used is re-implemented by the authors in Mathematica environment in order to combine it with commercial program. Since the procedure is still tested the random filed has been assumed as one-dimensional: the strength properties of soil are random in vertical direction only. Individual realizations of bearing capacity boundary-problem with strength parameters of medium defined the above procedure are solved using FLAC3D Software. The analysis is performed for two qualitatively different cases, namely for the purely cohesive and cohesive-frictional soils. For the latter case the friction angle and cohesion have been assumed as independent random variables. For these two cases the random square footing bearing capacity results have been obtained for the range of fluctuation scales from 0.5 m to 10 m. Each time 1000 Monte Carlo realizations have been performed. The obtained results allow not only the mean and variance but also the probability density function to be estimated. An example of application of this function for reliability calculation has been presented in the final part of the paper.

  4. Dynamic Stiffness Transfer Function of an Electromechanical Actuator Using System Identification

    NASA Astrophysics Data System (ADS)

    Kim, Sang Hwa; Tahk, Min-Jea

    2018-04-01

    In the aeroelastic analysis of flight vehicles with electromechanical actuators (EMAs), an accurate prediction of flutter requires dynamic stiffness characteristics of the EMA. The dynamic stiffness transfer function of the EMA with brushless direct current (BLDC) motor can be obtained by conducting complicated mathematical calculations of control algorithms and mechanical/electrical nonlinearities using linearization techniques. Thus, system identification approaches using experimental data, as an alternative, have considerable advantages. However, the test setup for system identification is expensive and complex, and experimental procedures for data collection are time-consuming tasks. To obtain the dynamic stiffness transfer function, this paper proposes a linear system identification method that uses information obtained from a reliable dynamic stiffness model with a control algorithm and nonlinearities. The results of this study show that the system identification procedure is compact, and the transfer function is able to describe the dynamic stiffness characteristics of the EMA. In addition, to verify the validity of the system identification method, the simulation results of the dynamic stiffness transfer function and the dynamic stiffness model were compared with the experimental data for various external loads.

  5. High-order time-marching reinitialization for regional level-set functions

    NASA Astrophysics Data System (ADS)

    Pan, Shucheng; Lyu, Xiuxiu; Hu, Xiangyu Y.; Adams, Nikolaus A.

    2018-02-01

    In this work, the time-marching reinitialization method is extended to compute the unsigned distance function in multi-region systems involving arbitrary number of regions. High order and interface preservation are achieved by applying a simple mapping that transforms the regional level-set function to the level-set function and a high-order two-step reinitialization method which is a combination of the closest point finding procedure and the HJ-WENO scheme. The convergence failure of the closest point finding procedure in three dimensions is addressed by employing a proposed multiple junction treatment and a directional optimization algorithm. Simple test cases show that our method exhibits 4th-order accuracy for reinitializing the regional level-set functions and strictly satisfies the interface-preserving property. The reinitialization results for more complex cases with randomly generated diagrams show the capability our method for arbitrary number of regions N, with a computational effort independent of N. The proposed method has been applied to dynamic interfaces with different types of flows, and the results demonstrate high accuracy and robustness.

  6. The Effect of the Extinction Procedure in Function-Based Intervention

    ERIC Educational Resources Information Center

    Janney, Donna M.; Umbreit, John; Ferro, Jolenea B.; Liaupsin, Carl J.; Lane, Kathleen L.

    2013-01-01

    In this study, we examined the contribution of the extinction procedure in function-based interventions implemented in the general education classrooms of three at-risk elementary-aged students. Function-based interventions included antecedent adjustments, reinforcement procedures, and function-matched extinction procedures. Using a combined ABC…

  7. 10 CFR 431.154 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Test procedures. 431.154 Section 431.154 Energy DEPARTMENT... EQUIPMENT Commercial Clothers Washers Test Procedures § 431.154 Test procedures. The test procedures for residential clothes washers in Appendix J1 to subpart B of part 430 of this title shall be used to test...

  8. Supercritical tests of a self-optimizing, variable-Camber wind tunnel model

    NASA Technical Reports Server (NTRS)

    Levinsky, E. S.; Palko, R. L.

    1979-01-01

    A testing procedure was used in a 16-foot Transonic Propulsion Wind Tunnel which leads to optimum wing airfoil sections without stopping the tunnel for model changes. Being experimental, the optimum shapes obtained incorporate various three-dimensional and nonlinear viscous and transonic effects not included in analytical optimization methods. The method is a closed-loop, computer-controlled, interactive procedure and employs a Self-Optimizing Flexible Technology wing semispan model that conformally adapts the airfoil section at two spanwise control stations to maximize or minimize various prescribed merit functions subject to both equality and inequality constraints. The model, which employed twelve independent hydraulic actuator systems and flexible skins, was also used for conventional testing. Although six of seven optimizations attempted were at least partially convergent, further improvements in model skin smoothness and hydraulic reliability are required to make the technique fully operational.

  9. Identifying fMRI Model Violations with Lagrange Multiplier Tests

    PubMed Central

    Cassidy, Ben; Long, Christopher J; Rae, Caroline; Solo, Victor

    2013-01-01

    The standard modeling framework in Functional Magnetic Resonance Imaging (fMRI) is predicated on assumptions of linearity, time invariance and stationarity. These assumptions are rarely checked because doing so requires specialised software, although failure to do so can lead to bias and mistaken inference. Identifying model violations is an essential but largely neglected step in standard fMRI data analysis. Using Lagrange Multiplier testing methods we have developed simple and efficient procedures for detecting model violations such as non-linearity, non-stationarity and validity of the common Double Gamma specification for hemodynamic response. These procedures are computationally cheap and can easily be added to a conventional analysis. The test statistic is calculated at each voxel and displayed as a spatial anomaly map which shows regions where a model is violated. The methodology is illustrated with a large number of real data examples. PMID:22542665

  10. Office procedures for quantitative assessment of olfactory function.

    PubMed

    Doty, Richard L

    2007-01-01

    Despite the importance of the sense of smell for establishing the flavor of foods and beverages, as well as protecting against environmental dangers, this primary sensory system is commonly ignored by the rhinologist. In this article basic issues related to practical measurement of olfactory function in the clinic are described and examples of the application of the two most common paradigms for such measurement--odor identification and detection--are presented. A listing is made of the 27 olfactory tests currently used clinically, along with their strengths and weaknesses. A brief review of common nasosinus-related disorders for which quantitative olfactory testing has been performed is provided. Although many psychophysical tests are available for quantifying olfactory loss, it is apparent that a number are limited in terms of practicality, sensitivity, and reliability. In general, sensitivity and reliability are positively correlated with test length. Given the strengths of the more reliable forced-choice pyschophysical tests and the limitations of electrophysiological tests, the common distinction between "subjective" and "objective" tests is misleading and should not be used. Complete recovery of olfactory function, as measured quantitatively, rarely follows surgical or medical interventions in patients with rhinosinusitis. Given the availability of practical clinical olfactory tests, the modern rhinologist can easily quantify cranial nerve (CN) I function. The application of such tests has led to a new understanding of the effects of nasal disease on olfactory function. Except in cases of total or near-total nasal obstruction, olfactory and airway patency measures usually are unrelated, in accord with the concept that rhinosinusitis primarily influences olfactory function by apoptotic pathological changes within the olfactory neuroepithelium.

  11. On the Crack Bifurcation and Fanning of Crack Growth Data

    NASA Technical Reports Server (NTRS)

    Forman, Royce G.; Zanganeh, Mohammad

    2015-01-01

    Crack growth data obtained from ASTM load shedding method for different R values show some fanning especially for aluminum alloys. It is believed by the authors and it has been shown before that the observed fanning is due to the crack bifurcation occurs in the near threshold region which is a function of intrinsic properties of the alloy. Therefore, validity of the ASTM load shedding test procedure and results is confirmed. However, this position has been argued by some experimentalists who believe the fanning is an artifact of the test procedure and thus the obtained results are invalid. It has been shown that using a special test procedure such as using compressively pre-cracked specimens will eliminate the fanning effect. Since not using the fanned data fit can result in a significantly lower calculated cyclic life, design of a component, particularly for rotorcraft and propeller systems will considerably be impacted and therefore this study is of paramount importance. In this effort both test procedures i.e. ASTM load shedding and the proposed compressive pre-cracking have been used to study the fatigue crack growth behavior of compact tension specimens made of aluminum alloy 2524-T3. Fatigue crack growth paths have been closely observed using SEM machines to investigate the effects of compression pre-cracking on the crack bifurcation behavior. The results of this study will shed a light on resolving the existing argument by better understanding of near threshold fatigue crack growth behavior.

  12. Phylogenomics of plant genomes: a methodology for genome-wide searches for orthologs in plants

    PubMed Central

    Conte, Matthieu G; Gaillard, Sylvain; Droc, Gaetan; Perin, Christophe

    2008-01-01

    Background Gene ortholog identification is now a major objective for mining the increasing amount of sequence data generated by complete or partial genome sequencing projects. Comparative and functional genomics urgently need a method for ortholog detection to reduce gene function inference and to aid in the identification of conserved or divergent genetic pathways between several species. As gene functions change during evolution, reconstructing the evolutionary history of genes should be a more accurate way to differentiate orthologs from paralogs. Phylogenomics takes into account phylogenetic information from high-throughput genome annotation and is the most straightforward way to infer orthologs. However, procedures for automatic detection of orthologs are still scarce and suffer from several limitations. Results We developed a procedure for ortholog prediction between Oryza sativa and Arabidopsis thaliana. Firstly, we established an efficient method to cluster A. thaliana and O. sativa full proteomes into gene families. Then, we developed an optimized phylogenomics pipeline for ortholog inference. We validated the full procedure using test sets of orthologs and paralogs to demonstrate that our method outperforms pairwise methods for ortholog predictions. Conclusion Our procedure achieved a high level of accuracy in predicting ortholog and paralog relationships. Phylogenomic predictions for all validated gene families in both species were easily achieved and we can conclude that our methodology outperforms similarly based methods. PMID:18426584

  13. Phase-Based Adaptive Estimation of Magnitude-Squared Coherence Between Turbofan Internal Sensors and Far-Field Microphone Signals

    NASA Technical Reports Server (NTRS)

    Miles, Jeffrey Hilton

    2015-01-01

    A cross-power spectrum phase based adaptive technique is discussed which iteratively determines the time delay between two digitized signals that are coherent. The adaptive delay algorithm belongs to a class of algorithms that identifies a minimum of a pattern matching function. The algorithm uses a gradient technique to find the value of the adaptive delay that minimizes a cost function based in part on the slope of a linear function that fits the measured cross power spectrum phase and in part on the standard error of the curve fit. This procedure is applied to data from a Honeywell TECH977 static-engine test. Data was obtained using a combustor probe, two turbine exit probes, and far-field microphones. Signals from this instrumentation are used estimate the post-combustion residence time in the combustor. Comparison with previous studies of the post-combustion residence time validates this approach. In addition, the procedure removes the bias due to misalignment of signals in the calculation of coherence which is a first step in applying array processing methods to the magnitude squared coherence data. The procedure also provides an estimate of the cross-spectrum phase-offset.

  14. Identifying and exploiting trait-relevant tissues with multiple functional annotations in genome-wide association studies

    PubMed Central

    Zhang, Shujun

    2018-01-01

    Genome-wide association studies (GWASs) have identified many disease associated loci, the majority of which have unknown biological functions. Understanding the mechanism underlying trait associations requires identifying trait-relevant tissues and investigating associations in a trait-specific fashion. Here, we extend the widely used linear mixed model to incorporate multiple SNP functional annotations from omics studies with GWAS summary statistics to facilitate the identification of trait-relevant tissues, with which to further construct powerful association tests. Specifically, we rely on a generalized estimating equation based algorithm for parameter inference, a mixture modeling framework for trait-tissue relevance classification, and a weighted sequence kernel association test constructed based on the identified trait-relevant tissues for powerful association analysis. We refer to our analytic procedure as the Scalable Multiple Annotation integration for trait-Relevant Tissue identification and usage (SMART). With extensive simulations, we show how our method can make use of multiple complementary annotations to improve the accuracy for identifying trait-relevant tissues. In addition, our procedure allows us to make use of the inferred trait-relevant tissues, for the first time, to construct more powerful SNP set tests. We apply our method for an in-depth analysis of 43 traits from 28 GWASs using tissue-specific annotations in 105 tissues derived from ENCODE and Roadmap. Our results reveal new trait-tissue relevance, pinpoint important annotations that are informative of trait-tissue relationship, and illustrate how we can use the inferred trait-relevant tissues to construct more powerful association tests in the Wellcome trust case control consortium study. PMID:29377896

  15. Cyclic Hardness Test PHYBALCHT: A New Short-Time Procedure to Estimate Fatigue Properties of Metallic Materials

    NASA Astrophysics Data System (ADS)

    Kramer, Hendrik; Klein, Marcus; Eifler, Dietmar

    Conventional methods to characterize the fatigue behavior of metallic materials are very time and cost consuming. That is why the new short-time procedure PHYBALCHT was developed at the Institute of Materials Science and Engineering at the University of Kaiserslautern. This innovative method requires only a planar material surface to perform cyclic force-controlled hardness indentation tests. To characterize the cyclic elastic-plastic behavior of the test material the change of the force-indentation-depth-hysteresis is plotted versus the number of indentation cycles. In accordance to the plastic strain amplitude the indentation-depth width of the hysteresis loop is measured at half minimum force and is called plastic indentation-depth amplitude. Its change as a function of the number of cycles of indentation can be described by power-laws. One of these power-laws contains the hardening-exponentCHT e II , which correlates very well with the amount of cyclic hardening in conventional constant amplitude fatigue tests.

  16. Clinical-scale validation of a new efficient procedure for cryopreservation of ex vivo expanded cord blood hematopoietic stem and progenitor cells.

    PubMed

    Duchez, Pascale; Rodriguez, Laura; Chevaleyre, Jean; De La Grange, Philippe Brunet; Ivanovic, Zoran

    2016-12-01

    Survival of ex vivo expanded hematopoietic stem cells (HSC) and progenitor cells is low with the standard cryopreservation procedure. We recently showed that the efficiency of cryopreservation of these cells may be greatly enhanced by adding a serum-free xeno-free culture medium (HP01 Macopharma), which improves the antioxidant and biochemical properties of the cryopreservation solution. Here we present the clinical-scale validation of this cryopreservation procedure. The hematopoietic cells expanded in clinical-scale cultures were cryopreserved applying the new HP01-based procedure. The viability, apoptosis rate and number of functional committed progenitors (methyl-cellulose colony forming cell test), short-term repopulating HSCs (primary recipient NSG mice) and long-term HSCs (secondary recipient NSG mice) were tested before and after thawing. The efficiency of clinical-scale procedure reproduced the efficiency of cryopreservation obtained earlier in miniature sample experiments. Furthermore, the full preservation of short- and long-term HSCs was obtained in clinical scale conditions. Because the results obtained in clinical-scale volume are comparable to our earlier results in miniature-scale cultures, the clinical-scale procedure should be considered validated. It allows cryopreservation of the whole ex vivo expanded culture content, conserving full short- and long-term HSC activity. Copyright © 2016 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  17. Effect of a novel mobilization with movement procedure on anterolateral ankle impingement - A case report.

    PubMed

    Anandkumar, Sudarshan

    2018-07-01

    This case report describes a 50-year-old male who presented with right anterolateral ankle pain managed unsuccessfully with rest, medications, bracing, injection, physical therapy, and massage therapy. Clinical diagnosis of anterolateral ankle impingement was based on concordant symptom reproduction with palpatory tenderness and a positive lateral synovial impingement test. This case report is a potential first time description of the successful management of anterolateral ankle impingement utilizing a novel Mulligan's mobilization with movement procedure (consisting of internal rotation of the distal tibia) and taping with immediate improvements noted in pain, range of motion, and function. The patient was seen twice a week and was discharged after four treatment sessions. A follow-up after 4 months revealed that the patient was pain free and fully functional.

  18. Incorporating data link messaging into a multi-function display to support the Small Aircraft Transportation System (SATS) and the self-separation of general aviation aircraft.

    PubMed

    Adams, Catherine A; Murdoch, Jennifer L; Consiglio, Maria C; Williams, Daniel M

    2007-07-01

    One objective of the Small Aircraft Transportation System (SATS) Project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated system and separation responsibilities to general aviation (GA) pilots. This paper describes the development of a research multi-function display (MFD) to support the interaction between pilots and an automated Airport Management Module (AMM). Preliminary results of simulation and flight tests indicate that adding the responsibility of monitoring other traffic for self-separation does not increase pilots' subjective workload levels. Pilots preferred using the enhanced MFD to execute flight procedures, reporting improved situation awareness (SA) over conventional instrument flight rules (IFR) procedures.

  19. 40 CFR 63.694 - Testing methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Testing methods and procedures. 63.694....694 Testing methods and procedures. (a) This section specifies the testing methods and procedures... this subpart, the testing methods and procedures are specified in paragraph (b) of this section. (2) To...

  20. 40 CFR 86.425-78 - Test procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Test procedures. 86.425-78 Section 86... Later New Motorcycles, General Provisions § 86.425-78 Test procedures. (a) Motorcycle emission test procedures are found in subpart F. (b) The Administrator may prescribe emission test procedures for any...

  1. 40 CFR 86.425-78 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Test procedures. 86.425-78 Section 86... Later New Motorcycles, General Provisions § 86.425-78 Test procedures. (a) Motorcycle emission test procedures are found in subpart F. (b) The Administrator may prescribe emission test procedures for any...

  2. 40 CFR 86.425-78 - Test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Test procedures. 86.425-78 Section 86... Later New Motorcycles, General Provisions § 86.425-78 Test procedures. (a) Motorcycle emission test procedures are found in subpart F. (b) The Administrator may prescribe emission test procedures for any...

  3. 40 CFR 600.111-93 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Test procedures. 600.111-93 Section... Emission Regulations for 1978 and Later Model Year Automobiles-Test Procedures § 600.111-93 Test procedures. (a) The test procedures to be followed for generation of the city fuel economy data are those...

  4. 40 CFR 90.508 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Test procedures. 90.508 Section 90.508....508 Test procedures. (a) For nonroad engines subject to the provisions of this subpart, the prescribed test procedures are the appropriate small SI engine test procedures as described in subpart E of this...

  5. 40 CFR 89.508 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Test procedures. 89.508 Section 89.508... Test procedures. (a)(1) For nonroad engines subject to the provisions of this subpart, the prescribed test procedures are the nonroad engine 8-mode test procedure as described in subpart E of this part...

  6. 40 CFR 600.111-80 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Test procedures. 600.111-80 Section... Emission Regulations for 1978 and Later Model Year Automobiles-Test Procedures § 600.111-80 Test procedures. (a) The test procedures to be followed for generation of the city fuel economy data are those...

  7. 21 CFR 355.70 - Testing procedures for fluoride dentifrice drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Testing procedures for fluoride dentifrice drug... Procedures § 355.70 Testing procedures for fluoride dentifrice drug products. (a) A fluoride dentifrice drug... tests: Enamel solubility reduction or fluoride enamel uptake. The testing procedures for these...

  8. 21 CFR 355.70 - Testing procedures for fluoride dentifrice drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Testing procedures for fluoride dentifrice drug... Procedures § 355.70 Testing procedures for fluoride dentifrice drug products. (a) A fluoride dentifrice drug... tests: Enamel solubility reduction or fluoride enamel uptake. The testing procedures for these...

  9. NASA Summer Faculty Fellowship Program 2004, Volumes 1 and 2

    NASA Technical Reports Server (NTRS)

    Hyman, William A. (Editor); Sickorez, Donn G. (Editor); Leveritt, Dawn M. (Editor)

    2005-01-01

    The objective of the planned summer research was to develop a procedure to determine the isokinetic functional strength of suited and unsuited participants in order to estimate the coefficient of micro-gravity suit on human strength. To accomplish this objective, the Anthropometry and Biomechanics Facility Multipurpose, Multiaxial Isokinetic dynamometer (MMID) was used. Development of procedure involved selection and testing of seven routines to be tested on MMID. We conducted the related experiments and collected the data for 12 participants. In addition to the above objective, we developed a procedure to assess the fatiguing characteristics of suited and unsuited participants using EMG technique. We collected EMG data on 10 participants while performing a programmed routing on MMID. EMG data along with information on the exerted forces, effector speed, number of repetitions, and duration of each routine were recorded for further analysis. Finally, gathering and tabulation Of data for various human strengths for updating of MSIS (HSIS) strength requirement, which started in summer 2003, also continued.

  10. Dynamic testing in schizophrenia: does training change the construct validity of a test?

    PubMed

    Wiedl, Karl H; Schöttke, Henning; Green, Michael F; Nuechterlein, Keith H

    2004-01-01

    Dynamic testing typically involves specific interventions for a test to assess the extent to which test performance can be modified, beyond level of baseline (static) performance. This study used a dynamic version of the Wisconsin Card Sorting Test (WCST) that is based on cognitive remediation techniques within a test-training-test procedure. From results of previous studies with schizophrenia patients, we concluded that the dynamic and static versions of the WCST should have different construct validity. This hypothesis was tested by examining the patterns of correlations with measures of executive functioning, secondary verbal memory, and verbal intelligence. Results demonstrated a specific construct validity of WCST dynamic (i.e., posttest) scores as an index of problem solving (Tower of Hanoi) and secondary verbal memory and learning (Auditory Verbal Learning Test), whereas the impact of general verbal capacity and selective attention (Verbal IQ, Stroop Test) was reduced. It is concluded that the construct validity of the test changes with dynamic administration and that this difference helps to explain why the dynamic version of the WCST predicts functional outcome better than the static version.

  11. Standard operating procedures (SOPs): reason for, types of, adequacy, approval, and deviations from and revisions to.

    PubMed

    Isaman, V; Thelin, R

    1995-09-01

    Standard Operating Procedures (SOPs) are required in order to comply with the Good Laboratory Practice Standards (GLPS) as promulgated in the Federal Insecticide, Fungicide and Rodenticide Act (FIFRA) 40 CFR Part 160. Paragraph 160.81 (a) states: "A testing facility shall have standard operating procedures in writing setting forth study methods that management is satisfied are adequate to insure the quality and integrity of the data generated in the course of a study." Types of SOPs include administrative and personnel, analyses, substances, quality assurance and records, test system, equipment, and field related. All SOPs must be adequate in scope to describe the function in sufficient detail such that the study data are reproducible. All SOPs must be approved by a management level as described in a corporate organization chart. Signatures for SOP responsibility, authorship, and Quality Assurance review adds strength and accountability to the SOP. In the event a procedure or method is performed differently from what is stated in the SOP, an SOP deviation is necessary. As methods and procedures are improved, SOP revisions are necessary to maintain SOP adequacy and applicability. The replaced SOP is put into a historical SOP file and all copies of the replaced SOPs are destroyed.

  12. Comparisons of the Impact Responses of a 1/5-Scale Model and a Full-Scale Crashworthy Composite Fuselage Section

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Fasanella, Edwin L.; Lyle, Karen H.

    2003-01-01

    A 25-fps vertical drop test of a 1/5-scale model composite fuselage section was conducted to replicate a previous test of a full-scale fuselage section. The purpose of the test was to obtain experimental data characterizing the impact response of the 1/5-scale model fuselage section for comparison with the corresponding full-scale data. This comparison is performed to assess the scaling procedures and to determine if scaling effects are present. For the drop test, the 1/5-scale model fuselage section was configured in a similar manner as the full-scale section, with lead masses attached to the floor through simulated seat rails. Scaled acceleration and velocity responses are compared and a general assessment of structural damage is made. To further quantify the data correlation, comparisons of the average acceleration data are made as a function of floor location and longitudinal position. Also, the percentage differences in the velocity change (area under the acceleration curve) and the velocity change squared (proportional to kinetic energy) are compared as a function of floor location. Finally, correlation coefficients are calculated for corresponding 1/5- and full-scale data channels and these values are plotted versus floor location. From a scaling perspective, the differences between the 1/5- and full-scale tests are relatively small, indicating that appropriate scaling procedures were used in fabricating the test specimens and in conducting the experiments. The small differences in the scaled test data are attributed to minor scaling anomalies in mass, potential energy, and impact attitude.

  13. Influence of mechanical cell salvage on red blood cell aggregation, deformability, and 2,3-diphosphoglycerate in patients undergoing cardiac surgery with cardiopulmonary bypass.

    PubMed

    Gu, Y John; Vermeijden, Wytze J; de Vries, Adrianus J; Hagenaars, J Ans M; Graaff, Reindert; van Oeveren, Willem

    2008-11-01

    Mechanical cell salvage is increasingly used during cardiac surgery. Although this procedure is considered safe, it is unknown whether it affects the red blood cell (RBC) function, especially the RBC aggregation, deformability, and the contents of 2,3-diphosphoglycerate (2,3-DPG). This study examines the following: (1) whether the cell salvage procedure influences RBC function; and (2) whether retransfusion of the salvaged blood affects RBC function in patients. Forty patients undergoing cardiac surgery with cardiopulmonary bypass were randomly allocated to a cell saver group (n = 20) or a control group (n = 20). In the cell saver group, the blood aspirated from the wound area and the residual blood from the heart-lung machine were processed with a continuous-flow cell saver before retransfusion. In the control group this blood was retransfused without processing. The RBC aggregation and deformability were measured with a laser-assisted optical rotational cell analyzer and 2,3,-DPG by conventional laboratory test. The cell saver procedure did not influence the RBC aggregation but significantly reduced the RBC deformability (p = 0.007) and the content of RBC 2,3-DPG (p = 0.032). However, in patients receiving the processed blood, their intraoperative and postoperative RBC aggregation, deformability, and 2,3-DPG content did not differ from those of the control patients. Both groups of patients had a postoperative drop of RBC function as a result of hemodilution. The mechanical cell salvage procedure reduces the RBC deformability and the cell 2,3-DPG content. Retransfusion of the processed blood by cell saver does not further compromise the RBC function in patients undergoing cardiac surgery with cardiopulmonary bypass.

  14. Toddler test or procedure preparation

    MedlinePlus

    Preparing toddler for test/procedure; Test/procedure preparation - toddler; Preparing for a medical test or procedure - toddler ... Before the test, know that your child will probably cry. Even if you prepare, your child may feel some discomfort or ...

  15. Identification of potential neuromotor mechanisms of manual therapy in patients with musculoskeletal disablement: rationale and description of a clinical trial.

    PubMed

    Fisher, Beth E; Davenport, Todd E; Kulig, Kornelia; Wu, Allan D

    2009-05-21

    Many health care practitioners use a variety of hands-on treatments to improve symptoms and disablement in patients with musculoskeletal pathology.Research to date indirectly suggests a potentially broad effect of manual therapy on the neuromotor processing of functional behavior within the supraspinal central nervous system (CNS) in a manner that may be independent of modification at the level of local spinal circuits. However, the effect of treatment speed, as well as the specific mechanism and locus of CNS changes, remain unclear. We developed a placebo-controlled, randomized study to test the hypothesis that manual therapy procedures directed to the talocrural joint in individuals with post-acute ankle sprain induce a change in corticospinal excitability that is relevant to improve the performance of lower extremity functional behavior. This study is designed to identify potential neuromotor changes associated with manual therapy procedures directed to the appendicular skeleton, compare the relative effect of treatment speed on potential neuromotor effects of manual therapy procedures, and determine the behavioral relevance of potential neuromotor effects of manual therapy procedures. http://www.clinicaltrials.gov identifier NCT00847769.

  16. Evaluative procedures to detect, characterize, and assess the severity of diabetic neuropathy.

    PubMed

    Dyck, P J

    1991-01-01

    Minimal criteria for diabetic neuropathy need to be defined and universally applied. Standardized evaluative procedures need to be agreed and normal ranges determined from healthy volunteers. Types and stages of neuropathy should be established and assessments performed on representative populations of both Type 1 and Type 2 diabetic patients. Potential minimal criteria include absent ankle reflexes and vibratory sensation, and abnormalities of nerve conduction. However, the preferred criterion is the identification of more than two statistically defined abnormalities among symptoms and deficits, nerve conduction, quantitative sensory examination or quantitative autonomic examination. Various evaluative procedures are available. Symptoms should be assessed and scores can be assigned to neurological deficits. However, assessments of nerve conduction provide the most specific, objective, sensitive, and repeatable procedures, although these may be the least meaningful. Many techniques are available for quantitative sensory examination, but are poorly standardized and normal values are not available. For quantitative autonomic examination, tests are available for the adequacy of cardiovascular and peripheral vascular reflexes and increasingly for other autonomic functions. In any assessment of nerve function the conditions should be optimized and standardized, and stimuli defined. Specific instructions should be given and normal ranges established in healthy volunteers.

  17. Identification of potential neuromotor mechanisms of manual therapy in patients with musculoskeletal disablement: rationale and description of a clinical trial

    PubMed Central

    Fisher, Beth E; Davenport, Todd E; Kulig, Kornelia; Wu, Allan D

    2009-01-01

    Background Many health care practitioners use a variety of hands-on treatments to improve symptoms and disablement in patients with musculoskeletal pathology. Research to date indirectly suggests a potentially broad effect of manual therapy on the neuromotor processing of functional behavior within the supraspinal central nervous system (CNS) in a manner that may be independent of modification at the level of local spinal circuits. However, the effect of treatment speed, as well as the specific mechanism and locus of CNS changes, remain unclear. Methods/Design We developed a placebo-controlled, randomized study to test the hypothesis that manual therapy procedures directed to the talocrural joint in individuals with post-acute ankle sprain induce a change in corticospinal excitability that is relevant to improve the performance of lower extremity functional behavior. Discussion This study is designed to identify potential neuromotor changes associated with manual therapy procedures directed to the appendicular skeleton, compare the relative effect of treatment speed on potential neuromotor effects of manual therapy procedures, and determine the behavioral relevance of potential neuromotor effects of manual therapy procedures. Trial Registration identifier NCT00847769. PMID:19460169

  18. Acoustic emission testing of composite vessels under sustained loading

    NASA Technical Reports Server (NTRS)

    Lark, R. F.; Moorhead, P. E.

    1978-01-01

    Acoustic emission (AE) tests have been conducted on small-diameter Kevlar 49/epoxy pressure vessels subjected to long-term sustained load-to-failure tests. Single-cycle burst tests were used as a basis for determining the test pressure in the sustained-loading tests. AE data from two vessel locations were compared. The data suggest that AE from vessel wall-mounted transducers is quite different for identical vessels subjected to the same pressure loading. AE from boss-mounted transducers yielded relatively consistent values. These values were not a function of time for vessel failure. The development of an AE test procedure for predicting the residual service life or integrity of composite vessels is discussed.

  19. Transformations of Mathematical and Stimulus Functions

    PubMed Central

    Ninness, Chris; Barnes-Holmes, Dermot; Rumph, Robin; McCuller, Glen; Ford, Angela M; Payne, Robert; Ninness, Sharon K; Smith, Ronald J; Ward, Todd A; Elliott, Marc P

    2006-01-01

    Following a pretest, 8 participants who were unfamiliar with algebraic and trigonometric functions received a brief presentation on the rectangular coordinate system. Next, they participated in a computer-interactive matching-to-sample procedure that trained formula-to-formula and formula-to-graph relations. Then, they were exposed to 40 novel formula-to-graph tests and 10 novel graph-to-formula tests. Seven of the 8 participants showed substantial improvement in identifying formula-to-graph relations; however, in the test of novel graph-to-formula relations, participants tended to select equations in their factored form. Next, we manipulated contextual cues in the form of rules regarding mathematical preferences. First, we informed participants that standard forms of equations were preferred over factored forms. In a subsequent test of 10 additional novel graph-to-formula relations, participants shifted their selections to favor equations in their standard form. This preference reversed during 10 more tests when financial reward was made contingent on correct identification of formulas in factored form. Formula preferences and transformation of novel mathematical and stimulus functions are discussed. PMID:17020211

  20. 40 CFR 86.884-5 - Test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Test procedures. 86.884-5 Section 86... New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-5 Test procedures. The procedures described in this and subsequent sections will be the test program to determine the conformity of engines...

  1. 40 CFR 86.608-98 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Test procedures. 86.608-98 Section 86... New Light-Duty Vehicles, Light-Duty Trucks, and Heavy-Duty Vehicles § 86.608-98 Test procedures. (a) The prescribed test procedures are the Federal Test Procedure, as described in subpart B of this part...

  2. 40 CFR 86.608-98 - Test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Test procedures. 86.608-98 Section 86... Auditing of New Light-Duty Vehicles, Light-Duty Trucks, and Heavy-Duty Vehicles § 86.608-98 Test procedures. (a) The prescribed test procedures are the Federal Test Procedure, as described in subpart B and/or...

  3. 14 CFR Appendix F to Part 23 - Test Procedure

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Test Procedure F Appendix F to Part 23...—Test Procedure Part I—Acceptable Test Procedure for Self-Extinguishing Materials for Showing Compliance With §§ 23.853, 23.855, and 23.1359 Acceptable test procedure for self-extinguishing materials for...

  4. 40 CFR 600.111-08 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Test procedures. 600.111-08 Section... Emission Regulations for 1978 and Later Model Year Automobiles-Test Procedures § 600.111-08 Test procedures. This section provides test procedures for the FTP, highway, US06, SC03, and the cold temperature FTP...

  5. 14 CFR Appendix F to Part 23 - Test Procedure

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Test Procedure F Appendix F to Part 23...—Test Procedure Part I—Acceptable Test Procedure for Self-Extinguishing Materials for Showing Compliance With §§ 23.853, 23.855, and 23.1359 Acceptable test procedure for self-extinguishing materials for...

  6. 40 CFR 86.884-5 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Test procedures. 86.884-5 Section 86... Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-5 Test procedures. The procedures described in this and subsequent sections will be the test program to determine the conformity of engines with the...

  7. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Test procedures and standards. 51.357... Requirements § 51.357 Test procedures and standards. Written test procedures and pass/fail standards shall be established and followed for each model year and vehicle type included in the program. (a) Test procedure...

  8. Automatic Nanodesign Using Evolutionary Techniques

    NASA Technical Reports Server (NTRS)

    Globus, Al; Saini, Subhash (Technical Monitor)

    1998-01-01

    Many problems associated with the development of nanotechnology require custom designed molecules. We use genetic graph software, a new development, to automatically evolve molecules of interest when only the requirements are known. Genetic graph software designs molecules, and potentially nanoelectronic circuits, given a fitness function that determines which of two molecules is better. A set of molecules, the first generation, is generated at random then tested with the fitness function, Subsequent generations are created by randomly choosing two parent molecules with a bias towards high scoring molecules, tearing each molecules in two at random, and mating parts from the mother and father to create two children. This procedure is repeated until a satisfactory molecule is found. An atom pair similarity test is currently used as the fitness function to evolve molecules similar to existing pharmaceuticals.

  9. Reliability, robustness, and reproducibility in mouse behavioral phenotyping: a cross-laboratory study

    PubMed Central

    Mandillo, Silvia; Tucci, Valter; Hölter, Sabine M.; Meziane, Hamid; Banchaabouchi, Mumna Al; Kallnik, Magdalena; Lad, Heena V.; Nolan, Patrick M.; Ouagazzal, Abdel-Mouttalib; Coghill, Emma L.; Gale, Karin; Golini, Elisabetta; Jacquot, Sylvie; Krezel, Wojtek; Parker, Andy; Riet, Fabrice; Schneider, Ilka; Marazziti, Daniela; Auwerx, Johan; Brown, Steve D. M.; Chambon, Pierre; Rosenthal, Nadia; Tocchini-Valentini, Glauco; Wurst, Wolfgang

    2008-01-01

    Establishing standard operating procedures (SOPs) as tools for the analysis of behavioral phenotypes is fundamental to mouse functional genomics. It is essential that the tests designed provide reliable measures of the process under investigation but most importantly that these are reproducible across both time and laboratories. For this reason, we devised and tested a set of SOPs to investigate mouse behavior. Five research centers were involved across France, Germany, Italy, and the UK in this study, as part of the EUMORPHIA program. All the procedures underwent a cross-validation experimental study to investigate the robustness of the designed protocols. Four inbred reference strains (C57BL/6J, C3HeB/FeJ, BALB/cByJ, 129S2/SvPas), reflecting their use as common background strains in mutagenesis programs, were analyzed to validate these tests. We demonstrate that the operating procedures employed, which includes open field, SHIRPA, grip-strength, rotarod, Y-maze, prepulse inhibition of acoustic startle response, and tail flick tests, generated reproducible results between laboratories for a number of the test output parameters. However, we also identified several uncontrolled variables that constitute confounding factors in behavioral phenotyping. The EUMORPHIA SOPs described here are an important start-point for the ongoing development of increasingly robust phenotyping platforms and their application in large-scale, multicentre mouse phenotyping programs. PMID:18505770

  10. Assessment of driving after stroke--a pluridisciplinary task.

    PubMed

    Ponsford, A-S; Viitanen, M; Lundberg, C; Johansson, K

    2008-03-01

    The aim of the study was to analyze the assessment procedure and identify predictors for the team decision when assessing fitness to drive a car after stroke. The material used was a retrospective data set with 200 stroke clients from Queen Elisabeth's Foundation Mobility Centre at Banstead UK. Fifty-four percent of clients were considered fit to continue driving where 9% could resume driving after car adaptation and training. Important factors for the outcome were vision (acuity and field), neuropsychological functions (divided attention), and track and/or on road test (reaction time, anticipation, speed, and positioning). Cognitive impairment was the main problem in those who failed the driving test and judged not fit for continued driving. Car adaptation, mainly comprising infrared transmitted secondary controls together with automatic transmission was recommended in 35% of the cases. The contribution of different specialist groups appears to be necessary for an effective evaluation, but the assessment procedure can be done more cost-effectively by dividing it into two separate parts and removing certain subtests. The in-car track test is an important part of the assessment procedure with a high face validity and could in many cases make it unnecessary to perform in-traffic tests with unsafe drivers. Car adaptation is often necessary for a client with pronounced hemi-paresis and a full road test can for those only be performed after training the use of car controls.

  11. LAPR: An experimental aircraft pushbroom scanner

    NASA Technical Reports Server (NTRS)

    Wharton, S. W.; Irons, J. I.; Heugel, F.

    1980-01-01

    A three band Linear Array Pushbroom Radiometer (LAPR) was built and flown on an experimental basis by NASA at the Goddard Space Flight Center. The functional characteristics of the instrument and the methods used to preprocess the data, including radiometric correction, are described. The radiometric sensitivity of the instrument was tested and compared to that of the Thematic Mapper and the Multispectral Scanner. The radiometric correction procedure was evaluated quantitatively, using laboratory testing, and qualitatively, via visual examination of the LAPR test flight imagery. Although effective radiometric correction could not yet be demonstrated via laboratory testing, radiometric distortion did not preclude the visual interpretation or parallel piped classification of the test imagery.

  12. Functional and effective brain connectivity for discrimination between Alzheimer's patients and healthy individuals: A study on resting state EEG rhythms.

    PubMed

    Blinowska, Katarzyna J; Rakowski, Franciszek; Kaminski, Maciej; De Vico Fallani, Fabrizio; Del Percio, Claudio; Lizio, Roberta; Babiloni, Claudio

    2017-04-01

    This exploratory study provided a proof of concept of a new procedure using multivariate electroencephalographic (EEG) topographic markers of cortical connectivity to discriminate normal elderly (Nold) and Alzheimer's disease (AD) individuals. The new procedure was tested on an existing database formed by resting state eyes-closed EEG data (19 exploring electrodes of 10-20 system referenced to linked-ear reference electrodes) recorded in 42 AD patients with dementia (age: 65.9years±8.5 standard deviation, SD) and 42 Nold non-consanguineous caregivers (age: 70.6years±8.5 SD). In this procedure, spectral EEG coherence estimated reciprocal functional connectivity while non-normalized directed transfer function (NDTF) estimated effective connectivity. Principal component analysis and computation of Mahalanobis distance integrated and combined these EEG topographic markers of cortical connectivity. The area under receiver operating curve (AUC) indexed the classification accuracy. A good classification of Nold and AD individuals was obtained by combining the EEG markers derived from NDTF and coherence (AUC=86%, sensitivity=0.85, specificity=0.70). These encouraging results motivate a cross-validation study of the new procedure in age- and education-matched Nold, stable and progressing mild cognitive impairment individuals, and de novo AD patients with dementia. If cross-validated, the new procedure will provide cheap, broadly available, repeatable over time, and entirely non-invasive EEG topographic markers reflecting abnormal cortical connectivity in AD patients diagnosed by direct or indirect measurement of cerebral amyloid β and hyperphosphorylated tau peptides. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  13. Effects of environmental and pharmacological manipulations on a novel delayed nonmatching-to-sample 'working memory' procedure in unrestrained rhesus monkeys.

    PubMed

    Hutsell, Blake A; Banks, Matthew L

    2015-08-15

    Working memory is a domain of 'executive function.' Delayed nonmatching-to-sample (DNMTS) procedures are commonly used to examine working memory in both human laboratory and preclinical studies. The aim was to develop an automated DNMTS procedure maintained by food pellets in rhesus monkeys using a touch-sensitive screen attached to the housing chamber. Specifically, the DNMTS procedure was a 2-stimulus, 2-choice recognition memory task employing unidimensional discriminative stimuli and randomized delay interval presentations. DNMTS maintained a delay-dependent decrease in discriminability that was independent of the retention interval distribution. Eliminating reinforcer availability during a single delay session or providing food pellets before the session did not systematically alter accuracy, but did reduce total choices. Increasing the intertrial interval enhanced accuracy at short delays. Acute Δ(9)-THC pretreatment produced delay interval-dependent changes in the forgetting function at doses that did not alter total choices. Acute methylphenidate pretreatment only decreased total choices. All monkeys were trained to perform NMTS at the 1s training delay within 60 days of initiating operant touch training. Furthermore, forgetting functions were reliably delay interval-dependent and stable over the experimental period (∼6 months). Consistent with previous studies, increasing the intertrial interval improved DNMTS performance, whereas Δ(9)-THC disrupted DNMTS performance independent of changes in total choices. Overall, the touchscreen-based DNMTS procedure described provides an efficient method for training and testing experimental manipulations on working memory in unrestrained rhesus monkeys. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Bon-EV: an improved multiple testing procedure for controlling false discovery rates.

    PubMed

    Li, Dongmei; Xie, Zidian; Zand, Martin; Fogg, Thomas; Dye, Timothy

    2017-01-03

    Stability of multiple testing procedures, defined as the standard deviation of total number of discoveries, can be used as an indicator of variability of multiple testing procedures. Improving stability of multiple testing procedures can help to increase the consistency of findings from replicated experiments. Benjamini-Hochberg's and Storey's q-value procedures are two commonly used multiple testing procedures for controlling false discoveries in genomic studies. Storey's q-value procedure has higher power and lower stability than Benjamini-Hochberg's procedure. To improve upon the stability of Storey's q-value procedure and maintain its high power in genomic data analysis, we propose a new multiple testing procedure, named Bon-EV, to control false discovery rate (FDR) based on Bonferroni's approach. Simulation studies show that our proposed Bon-EV procedure can maintain the high power of the Storey's q-value procedure and also result in better FDR control and higher stability than Storey's q-value procedure for samples of large size(30 in each group) and medium size (15 in each group) for either independent, somewhat correlated, or highly correlated test statistics. When sample size is small (5 in each group), our proposed Bon-EV procedure has performance between the Benjamini-Hochberg procedure and the Storey's q-value procedure. Examples using RNA-Seq data show that the Bon-EV procedure has higher stability than the Storey's q-value procedure while maintaining equivalent power, and higher power than the Benjamini-Hochberg's procedure. For medium or large sample sizes, the Bon-EV procedure has improved FDR control and stability compared with the Storey's q-value procedure and improved power compared with the Benjamini-Hochberg procedure. The Bon-EV multiple testing procedure is available as the BonEV package in R for download at https://CRAN.R-project.org/package=BonEV .

  15. The Effect of ODC-Free Cleaning Techniques on Bearing Lifetimes in the Parched Elastohydrodynamic Regime

    NASA Technical Reports Server (NTRS)

    Jones, William R., Jr.; Toddy, Thomas J.; Predmore, Roamer; Shogrin, Bradley; Herrera-Fierro Pilar

    1997-01-01

    A parched elastohydrodynamic rig was used to determine relative bearing lifetimes as a function of cleaning procedures in a series of accelerated tests. Two ODC-free cleaning procedures (super critical CO2 and ultraviolet-ozone) were compared to a CFC-113 control. Bearings (52100 steel) were run in the counter rotating mode (equivalent to 4600 rpm) with a full complement (i.e. no retainer) and a single charge of lubricant (Krytox 143 AC). Test conditions included: an air atmosphere, 445N load, approx. 1.0 GPa mean Hertz stress. There was approximately a 50% reduction in life with bearings cleaned with UV/ozone and a 70% reduction in life with SFE CO2 when compared to the Freon control. Possible reasons for these decreases in lifetimes are presented.

  16. The Effect of ODC-Free Cleaning Techniques on Bearing Lifetimes in the Parched Elastohydrodynamic Regime

    NASA Technical Reports Server (NTRS)

    Jones, William R., Jr.; Toddy, Thomas J.; Predmore, Roamer; Shogrin, Bradley; Herrera-Fierro, Pilar

    1996-01-01

    A parched elastohydrodynamic rig was used to determine relative bearing lifetimes as a function of cleaning procedures in a series of accelerated tests. Two ODC-free cleaning procedures (super critical CO2 and ultraviolet-ozone) were compared to a CFC-113 control. Bearings (52100 steel) were run in the counter rotating mode (equivalent to 4600 rpm) with a full complement (i.e. no retainer) and a single charge of lubricant (Krytox 143 AC). Test conditions included: an air atmosphere, 445 N load, approx. 1.0 GPa mean Hertz stress. There was approximately a 50% reduction in life with bearings cleaned with UV/ozone and a 70% reduction in life with SFE CO2 when compared to the Freon control. Possible reasons for these decreases in lifetimes are presented.

  17. The Potential of Environmental Sensors for Improving the Mobility Performance of Mainstream Blind Students. Final Report.

    ERIC Educational Resources Information Center

    Weisgerber, Robert A.; deHaas, Carla

    The report describes an effort to develop and test instructional materials, techniques and procedures - ESSETS (environmental sensing, selection, evaluation and training system) - for teaching functionally blind young adults to use electronic travel aids (ETAs). Considered are development of training guidelines, field site selection and instructor…

  18. Least Squares Metric, Unidimensional Scaling of Multivariate Linear Models.

    ERIC Educational Resources Information Center

    Poole, Keith T.

    1990-01-01

    A general approach to least-squares unidimensional scaling is presented. Ordering information contained in the parameters is used to transform the standard squared error loss function into a discrete rather than continuous form. Monte Carlo tests with 38,094 ratings of 261 senators, and 1,258 representatives demonstrate the procedure's…

  19. Visual Pathway Deficit in Female Fragile X Premutation Carriers: A Potential Endophenotype

    ERIC Educational Resources Information Center

    Keri, Szabolcs; Benedek, Gyorgy

    2009-01-01

    Previous studies indicated impaired magnocellular (M) and relatively spared parvocellular (P) visual pathway functioning in patients with fragile X syndrome. In this study, we assessed M and P pathways in 22 female fragile X premutation carriers with normal intelligence and in 20 healthy non-carrier controls. Testing procedure included visual…

  20. Operationalizing Levels of Academic Mastery Based on Vygotsky's Theory: The Study of Mathematical Knowledge

    ERIC Educational Resources Information Center

    Nezhnov, Peter; Kardanova, Elena; Vasilyeva, Marina; Ludlow, Larry

    2015-01-01

    The present study tested the possibility of operationalizing levels of knowledge acquisition based on Vygotsky's theory of cognitive growth. An assessment tool (SAM-Math) was developed to capture a hypothesized hierarchical structure of mathematical knowledge consisting of procedural, conceptual, and functional levels. In Study 1, SAM-Math was…

  1. Life sciences laboratory breadboard simulations for shuttle

    NASA Technical Reports Server (NTRS)

    Taketa, S. T.; Simmonds, R. C.; Callahan, P. X.

    1975-01-01

    Breadboard simulations of life sciences laboratory concepts for conducting bioresearch in space were undertaken as part of the concept verification testing program. Breadboard simulations were conducted to test concepts of and scope problems associated with bioresearch support equipment and facility requirements and their operational integration for conducting manned research in earth orbital missions. It emphasized requirements, functions, and procedures for candidate research on crew members (simulated) and subhuman primates and on typical radioisotope studies in rats, a rooster, and plants.

  2. Human Engineering Procedures Guide

    DTIC Science & Technology

    1981-09-01

    Evaluation (CGE) 175 3.9-25 Sample Technical Order Functional 193 Evaluation Form 3.9-26 Sample Test Participant History Record 201 3.Q-27 Sample...4 TO furict. evaluation 5 HFTEMAN 0 6 Env and pert. mecas. equipment g 7 System records review * * 8 Test part. history record 0 * * 9 Interview~s 0...local air flow in the range of 0 to 1000 ft/minute. This device is most useful for determining crew comfort conditions. g) Hygrometer or Psychrometer

  3. SWI 1.10 Testing Process

    NASA Technical Reports Server (NTRS)

    Stokes, LeBarian

    2009-01-01

    This procedure establishes a system for performing testing in the Six-Degree-Of-Freedom Dynamic Test System (SDTS). Testing includes development and verification testing of customer supplied Test Articles (TAs) and other testing requirements, as requested. This procedure applies to all SDTS testing operations and equipment. The procedure provides an overview of testing performed in the SDTS including test identification requirements, test planning and procedure development, test and performance inspection, test data analysis, and test report generation.

  4. Advances in the indirect, descriptive, and experimental approaches to the functional analysis of problem behavior.

    PubMed

    Wightman, Jade; Julio, Flávia; Virués-Ortega, Javier

    2014-05-01

    Experimental functional analysis is an assessment methodology to identify the environmental factors that maintain problem behavior in individuals with developmental disabilities and in other populations. Functional analysis provides the basis for the development of reinforcement-based approaches to treatment. This article reviews the procedures, validity, and clinical implementation of the methodological variations of functional analysis and function-based interventions. We present six variations of functional analysis methodology in addition to the typical functional analysis: brief functional analysis, single-function tests, latency-based functional analysis, functional analysis of precursors, and trial-based functional analysis. We also present the three general categories of function-based interventions: extinction, antecedent manipulation, and differential reinforcement. Functional analysis methodology is a valid and efficient approach to the assessment of problem behavior and the selection of treatment strategies.

  5. Uncertainty Analysis of Inertial Model Attitude Sensor Calibration and Application with a Recommended New Calibration Method

    NASA Technical Reports Server (NTRS)

    Tripp, John S.; Tcheng, Ping

    1999-01-01

    Statistical tools, previously developed for nonlinear least-squares estimation of multivariate sensor calibration parameters and the associated calibration uncertainty analysis, have been applied to single- and multiple-axis inertial model attitude sensors used in wind tunnel testing to measure angle of attack and roll angle. The analysis provides confidence and prediction intervals of calibrated sensor measurement uncertainty as functions of applied input pitch and roll angles. A comparative performance study of various experimental designs for inertial sensor calibration is presented along with corroborating experimental data. The importance of replicated calibrations over extended time periods has been emphasized; replication provides independent estimates of calibration precision and bias uncertainties, statistical tests for calibration or modeling bias uncertainty, and statistical tests for sensor parameter drift over time. A set of recommendations for a new standardized model attitude sensor calibration method and usage procedures is included. The statistical information provided by these procedures is necessary for the uncertainty analysis of aerospace test results now required by users of industrial wind tunnel test facilities.

  6. Communication skills in individuals with spastic diplegia.

    PubMed

    Lamônica, Dionísia Aparecida Cusin; Paiva, Cora Sofia Takaya; Abramides, Dagma Venturini Marques; Biazon, Jamile Lozano

    2015-01-01

    To assess communication skills in children with spastic diplegia. The study included 20 subjects, 10 preschool children with spastic diplegia and 10 typical matched according to gender, mental age, and socioeconomic status. Assessment procedures were the following: interviews with parents, Stanford - Binet method, Gross Motor Function Classification System, Observing the Communicative Behavior, Vocabulary Test by Peabody Picture, Denver Developmental Screening Test II, MacArthur Development Inventory on Communicative Skills. Statistical analysis was performed using the values of mean, median, minimum and maximum value, and using Student's t-test, Mann-Whitney test, and Paired t-test. Individuals with spastic diplegia, when compared to their peers of the same mental age, presented no significant difference in relation to receptive and expressive vocabulary, fine motor skills, adaptive, personal-social, and language. The most affected area was the gross motor skills in individuals with spastic cerebral palsy. The participation in intervention procedures and the pairing of participants according to mental age may have approximated the performance between groups. There was no statistically significant difference in the comparison between groups, showing appropriate communication skills, although the experimental group has not behaved homogeneously.

  7. 75 FR 47817 - Notice of Availability: Test Tools and Test Procedures Approved for the Office of the National...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Notice of Availability: Test Tools and Test Procedures.... SUMMARY: This notice announces the availability of test tools and test procedures approved by the National... certification program. The approved test tools and test procedures are identified on the ONC Web site at: http...

  8. 77 FR 64343 - Notice of Availability: Test Tools and Test Procedures Approved for the Office of the National...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Notice of Availability: Test Tools and Test Procedures.... SUMMARY: This notice announces the availability of test tools and test procedures approved by the National... test tools and test procedures are identified on the ONC Web site at: http://www.healthit.gov/policy...

  9. Benchmarking Procedures for High-Throughput Context Specific Reconstruction Algorithms

    PubMed Central

    Pacheco, Maria P.; Pfau, Thomas; Sauter, Thomas

    2016-01-01

    Recent progress in high-throughput data acquisition has shifted the focus from data generation to processing and understanding of how to integrate collected information. Context specific reconstruction based on generic genome scale models like ReconX or HMR has the potential to become a diagnostic and treatment tool tailored to the analysis of specific individuals. The respective computational algorithms require a high level of predictive power, robustness and sensitivity. Although multiple context specific reconstruction algorithms were published in the last 10 years, only a fraction of them is suitable for model building based on human high-throughput data. Beside other reasons, this might be due to problems arising from the limitation to only one metabolic target function or arbitrary thresholding. This review describes and analyses common validation methods used for testing model building algorithms. Two major methods can be distinguished: consistency testing and comparison based testing. The first is concerned with robustness against noise, e.g., missing data due to the impossibility to distinguish between the signal and the background of non-specific binding of probes in a microarray experiment, and whether distinct sets of input expressed genes corresponding to i.e., different tissues yield distinct models. The latter covers methods comparing sets of functionalities, comparison with existing networks or additional databases. We test those methods on several available algorithms and deduce properties of these algorithms that can be compared with future developments. The set of tests performed, can therefore serve as a benchmarking procedure for future algorithms. PMID:26834640

  10. Preschooler test or procedure preparation

    MedlinePlus

    Preparing preschoolers for test/procedure; Test/procedure preparation - preschooler ... Preparing children for medical tests can reduce their anxiety. It can also make them less likely to cry and resist the procedure. Research shows that ...

  11. 77 FR 4203 - Energy Conservation Program: Test Procedures for General Service Fluorescent Lamps, General...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-27

    ...On September 14, 2011, the U.S. Department of Energy (DOE) issued a notice of proposed rulemaking (NOPR) to amend the test procedures for general service fluorescent lamps (GSFLs), general service incandescent lamps (GSILs), and incandescent reflector lamps (IRLs). That proposed rulemaking serves as the basis for today's action. DOE is amending its test procedures for GSFLs and GSILs established under the Energy Policy and Conservation Act (EPCA). DOE is not amending in this final rule the existing test procedure for IRLs established under EPCA. For GSFLs and GSILs, DOE is updating several references to the industry standards referenced in DOE's test procedures. DOE is also establishing a lamp lifetime test procedure for GSILs. These test procedures also provide the protocols upon which the Federal Trade Commission bases its energy guide label for these products. DOE's review of the GSFL, GSIL, and IRL test procedures fulfills the EPCA requirement that DOE review test procedures for all covered products at least once every seven years.

  12. A comparison of physical and psychological features of responders and non-responders to cervical facet blocks in chronic whiplash

    PubMed Central

    2013-01-01

    Background Cervical facet block (FB) procedures are often used as a diagnostic precursor to radiofrequency neurotomies (RFN) in the management of chronic whiplash associated disorders (WAD). Some individuals will respond to the FB procedures and others will not respond. Such responders and non-responders provided a sample of convenience to question whether there were differences in their physical and psychological features. This information may inform future predictive studies and ultimately the clinical selection of patients for FB procedures. Methods This cross-sectional study involved 58 individuals with chronic WAD who responded to cervical FB procedures (WAD_R); 32 who did not respond (WAD_NR) and 30 Healthy Controls (HC)s. Measures included: quantitative sensory tests (pressure; thermal pain thresholds; brachial plexus provocation test); nociceptive flexion reflex (NFR); motor function (cervical range of movement (ROM); activity of the superficial neck flexors during the cranio-cervical flexion test (CCFT). Self-reported measures were gained from the following questionnaires: neuropathic pain (s-LANSS); psychological distress (General Health Questionnaire-28), post-traumatic stress (PDS) and pain catastrophization (PCS). Individuals with chronic whiplash attended the laboratory once the effects of the blocks had abated and symptoms had returned. Results Following FB procedures, both WAD groups demonstrated generalized hypersensitivity to all sensory tests, decreased neck ROM and increased superficial muscle activity with the CCFT compared to controls (p < 0.05). There were no significant differences between WAD groups (all p > 0.05). Both WAD groups demonstrated psychological distress (GHQ-28; p < 0.05), moderate post-traumatic stress symptoms and pain catastrophization. The WAD_NR group also demonstrated increased medication intake and elevated PCS scores compared to the WAD_R group (p < 0.05). Conclusions Chronic WAD responders and non-responders to FB procedures demonstrate a similar presentation of sensory disturbance, motor dysfunction and psychological distress. Higher levels of pain catastrophization and greater medication intake were the only factors found to differentiate these groups. PMID:24188899

  13. Test Operations Procedure (TOP) 03-2-827 Test Procedures for Video Target Scoring Using Calibration Lights

    DTIC Science & Technology

    2016-04-04

    Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Test Operations Procedure (TOP) 03-2-827 Test Procedures for Video Target Scoring Using...ABSTRACT This Test Operations Procedure (TOP) describes typical equipment and procedures to setup and operate a Video Target Scoring System (VTSS) to...lights. 15. SUBJECT TERMS Video Target Scoring System, VTSS, witness screens, camera, target screen, light pole 16. SECURITY

  14. Radioaerosol lung imaging in chronic obstructive pulmonary disease. Comparison with pulmonary function tests and roentgenography. [/sup 113m/In, /sup 99m/Tc, /sup 133/Xe tracer techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramanna, L.; Tashkin, D.P.; Taplin, G.V.

    1975-11-01

    Seventy subjects with either no, mild, or definite evidence of pulmonary abnormality on screening studies volunteered to have detailed pulmonary function tests (PFTs), respiratory questionnaires, physical examinations, and /sup 113m/indium aerosol-inhalation lung imaging performed. Also, 22 and 52 of these subjects underwent /sup 133/xenon ventilation and lung perfusion imaging with /sup 99m/technetium-labelled macroaggregated albumin, and 56 had chest x-ray examinations performed. Results of the radionuclide lung-imaging procedures were compared with those of conventional PFTs and other clinical diagnostic procedures used to identify chronic obstructive pulmonary disease (COPD). Abnormal radioaerosol patterns were found in 32 of 33 subjects with abnormal findingsmore » on PFTs, whereas results of PFTs were abnormal in only 32 of 46 subjects with abnormal aerosol deposition. Aerosol lung images were abnormal more frequently than respiratory questionnaire responses, findings on physical examination, chest x-ray films, and perfusion lung images and with approximately the same frequency as /sup 133/xenon ventilation scintiscans. These results suggest that radioaerosol lung imaging may be a more sensitive indicator of early COPD than other diagnostic procedures, including maximal midexpiratory flow rates, single-breath nitrogen washout, and closing volume. Further studies are required to determine the physiologic and pathologic significance of isolated aerosol lung-imaging abnormalities.« less

  15. Effects of paired-object affordance in search tasks across the adult lifespan.

    PubMed

    Wulff, Melanie; Stainton, Alexandra; Rotshtein, Pia

    2016-06-01

    The study investigated the processes underlying the retrieval of action information about functional object pairs, focusing on the contribution of procedural and semantic knowledge. We further assessed whether the retrieval of action knowledge is affected by task demands and age. The contribution of procedural knowledge was examined by the way objects were selected, specifically whether active objects were selected before passive objects. The contribution of semantic knowledge was examined by manipulating the relation between targets and distracters. A touchscreen-based search task was used testing young, middle-aged, and elderly participants. Participants had to select by touching two targets among distracters using two search tasks. In an explicit action search task, participants had to select two objects which afforded a mutual action (e.g., functional pair: hammer-nail). Implicit affordance perception was tested using a visual color-matching search task; participants had to select two objects with the same colored frame. In both tasks, half of the colored targets also afforded an action. Overall, middle-aged participants performed better than young and elderly participants, specifically in the action task. Across participants in the action task, accuracy was increased when the distracters were semantically unrelated to the functional pair, while the opposite pattern was observed in the color task. This effect was enhanced with increased age. In the action task all participants utilized procedural knowledge, i.e., selected the active object before the passive object. This result supports the dual-route account from vision to action. Semantic knowledge contributed to both the action and the color task, but procedural knowledge associated with the direct route was primarily retrieved when the task was action-relevant. Across the adulthood lifespan, the data show inverted U-shaped effects of age on the retrieval of action knowledge. Age also linearly increased the involvement of the indirect (semantic) route and the integration of information of the direct and the indirect routes in selection processes. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Evaluation of stereoscopic display with visual function and interview

    NASA Astrophysics Data System (ADS)

    Okuyama, Fumio

    1999-05-01

    The influence of binocular stereoscopic (3D) television display on the human eye were compared with one of a 2D display, using human visual function testing and interviews. A 40- inch double lenticular display was used for 2D/3D comparison experiments. Subjects observed the display for 30 minutes at a distance 1.0 m, with a combination of 2D material and one of 3D material. The participants were twelve young adults. Main optometric test with visual function measured were visual acuity, refraction, phoria, near vision point, accommodation etc. The interview consisted of 17 questions. Testing procedures were performed just before watching, just after watching, and forty-five minutes after watching. Changes in visual function are characterized as prolongation of near vision point, decrease of accommodation and increase in phoria. 3D viewing interview results show much more visual fatigue in comparison with 2D results. The conclusions are: 1) change in visual function is larger and visual fatigue is more intense when viewing 3D images. 2) The evaluation method with visual function and interview proved to be very satisfactory for analyzing the influence of stereoscopic display on human eye.

  17. Hypothesis tests for stratified mark-specific proportional hazards models with missing covariates, with application to HIV vaccine efficacy trials.

    PubMed

    Sun, Yanqing; Qi, Li; Yang, Guangren; Gilbert, Peter B

    2018-05-01

    This article develops hypothesis testing procedures for the stratified mark-specific proportional hazards model with missing covariates where the baseline functions may vary with strata. The mark-specific proportional hazards model has been studied to evaluate mark-specific relative risks where the mark is the genetic distance of an infecting HIV sequence to an HIV sequence represented inside the vaccine. This research is motivated by analyzing the RV144 phase 3 HIV vaccine efficacy trial, to understand associations of immune response biomarkers on the mark-specific hazard of HIV infection, where the biomarkers are sampled via a two-phase sampling nested case-control design. We test whether the mark-specific relative risks are unity and how they change with the mark. The developed procedures enable assessment of whether risk of HIV infection with HIV variants close or far from the vaccine sequence are modified by immune responses induced by the HIV vaccine; this question is interesting because vaccine protection occurs through immune responses directed at specific HIV sequences. The test statistics are constructed based on augmented inverse probability weighted complete-case estimators. The asymptotic properties and finite-sample performances of the testing procedures are investigated, demonstrating double-robustness and effectiveness of the predictive auxiliaries to recover efficiency. The finite-sample performance of the proposed tests are examined through a comprehensive simulation study. The methods are applied to the RV144 trial. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. On the v-representabilty problem in density functional theory: Application to non-interacting systems

    DOE PAGES

    Dane, Markus; Gonis, Antonios

    2016-07-05

    Based on a computational procedure for determining the functional derivative with respect to the density of any antisymmetric N-particle wave function for a non-interacting system that leads to the density, we devise a test as to whether or not a wave function known to lead to a given density corresponds to a solution of a Schrödinger equation for some potential. We examine explicitly the case of non-interacting systems described by Slater determinants. Here, numerical examples for the cases of a one-dimensional square-well potential with infinite walls and the harmonic oscillator potential illustrate the formalism.

  19. Assessment of grammar optimizes language tasks for the intracarotid amobarbital procedure.

    PubMed

    Połczyńska, Monika; Kuhn, Taylor; You, S Christine; Walshaw, Patricia; Curtiss, Susan; Bookheimer, Susan

    2017-11-01

    A previous study showed that assessment of language laterality could be improved by adding grammar tests to the recovery phase of the intracarotid amobarbital procedure (IAP) (Połczyńska et al. 2014). The aim of this study was to further investigate the extent to which grammar tests lateralize language function during the recovery phase of the IAP in a larger patient sample. Forty patients with drug-resistant epilepsy (14 females, thirty-two right-handed, mean age 38.5years, SD=10.6) participated in this study. On EEG, 24 patients had seizures originating in the left hemisphere (LH), 13 in the right hemisphere (RH), and 4 demonstrated mixed seizure origin. Thirty participants (75%) had bilateral injections, and ten (25%) had unilateral injections (five RH and five LH). Based on results from the encoding phase, we segregated our study participants to a LH language dominant and a mixed dominance group. In the recovery phase of the IAP, the participants were administered a new grammar test (the CYCLE-N) and a standard language test. We analyzed the laterality index measure and effect sizes in the two tests. In the LH-dominant group, the CYCLE-N generated more profound language deficits in the recovery phase than the standard after injection to either hemisphere (p<0.001). At the same time, the laterality index for the grammar tasks was still higher than for the standard tests. Critically, the CYCLE-N administered in the recovery phase was nearly as effective as the standard tests given during the encoding phase. The results may be significant for individuals with epilepsy undergoing IAP. The grammar tests may be a highly efficient measure for lateralizing language function in the recovery phase. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Statistical grand rounds: a review of analysis and sample size calculation considerations for Wilcoxon tests.

    PubMed

    Divine, George; Norton, H James; Hunt, Ronald; Dienemann, Jacqueline

    2013-09-01

    When a study uses an ordinal outcome measure with unknown differences in the anchors and a small range such as 4 or 7, use of the Wilcoxon rank sum test or the Wilcoxon signed rank test may be most appropriate. However, because nonparametric methods are at best indirect functions of standard measures of location such as means or medians, the choice of the most appropriate summary measure can be difficult. The issues underlying use of these tests are discussed. The Wilcoxon-Mann-Whitney odds directly reflects the quantity that the rank sum procedure actually tests, and thus it can be a superior summary measure. Unlike the means and medians, its value will have a one-to-one correspondence with the Wilcoxon rank sum test result. The companion article appearing in this issue of Anesthesia & Analgesia ("Aromatherapy as Treatment for Postoperative Nausea: A Randomized Trial") illustrates these issues and provides an example of a situation for which the medians imply no difference between 2 groups, even though the groups are, in fact, quite different. The trial cited also provides an example of a single sample that has a median of zero, yet there is a substantial shift for much of the nonzero data, and the Wilcoxon signed rank test is quite significant. These examples highlight the potential discordance between medians and Wilcoxon test results. Along with the issues surrounding the choice of a summary measure, there are considerations for the computation of sample size and power, confidence intervals, and multiple comparison adjustment. In addition, despite the increased robustness of the Wilcoxon procedures relative to parametric tests, some circumstances in which the Wilcoxon tests may perform poorly are noted, along with alternative versions of the procedures that correct for such limitations. 

  1. 40 CFR 92.506 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Test procedures. 92.506 Section 92.506... and Audit Programs § 92.506 Test procedures. (a)(1) For locomotives and locomotive engines subject to the provisions of this subpart, the prescribed test procedures are those procedures described in...

  2. Comparing adaptive procedures for estimating the psychometric function for an auditory gap detection task.

    PubMed

    Shen, Yi

    2013-05-01

    A subject's sensitivity to a stimulus variation can be studied by estimating the psychometric function. Generally speaking, three parameters of the psychometric function are of interest: the performance threshold, the slope of the function, and the rate at which attention lapses occur. In the present study, three psychophysical procedures were used to estimate the three-parameter psychometric function for an auditory gap detection task. These were an up-down staircase (up-down) procedure, an entropy-based Bayesian (entropy) procedure, and an updated maximum-likelihood (UML) procedure. Data collected from four young, normal-hearing listeners showed that while all three procedures provided similar estimates of the threshold parameter, the up-down procedure performed slightly better in estimating the slope and lapse rate for 200 trials of data collection. When the lapse rate was increased by mixing in random responses for the three adaptive procedures, the larger lapse rate was especially detrimental to the efficiency of the up-down procedure, and the UML procedure provided better estimates of the threshold and slope than did the other two procedures.

  3. Bottom-up laboratory testing of the DKIST Visible Broadband Imager (VBI)

    NASA Astrophysics Data System (ADS)

    Ferayorni, Andrew; Beard, Andrew; Cole, Wes; Gregory, Scott; Wöeger, Friedrich

    2016-08-01

    The Daniel K. Inouye Solar Telescope (DKIST) is a 4-meter solar observatory under construction at Haleakala, Hawaii [1]. The Visible Broadband Imager (VBI) is a first light instrument that will record images at the highest possible spatial and temporal resolution of the DKIST at a number of scientifically important wavelengths [2]. The VBI is a pathfinder for DKIST instrumentation and a test bed for developing processes and procedures in the areas of unit, systems integration, and user acceptance testing. These test procedures have been developed and repeatedly executed during VBI construction in the lab as part of a "test early and test often" philosophy aimed at identifying and resolving issues early thus saving cost during integration test and commissioning on summit. The VBI team recently completed a bottom up end-to-end system test of the instrument in the lab that allowed the instrument's functionality, performance, and usability to be validated against documented system requirements. The bottom up testing approach includes four levels of testing, each introducing another layer in the control hierarchy that is tested before moving to the next level. First the instrument mechanisms are tested for positioning accuracy and repeatability using a laboratory position-sensing detector (PSD). Second the real-time motion controls are used to drive the mechanisms to verify speed and timing synchronization requirements are being met. Next the high-level software is introduced and the instrument is driven through a series of end-to-end tests that exercise the mechanisms, cameras, and simulated data processing. Finally, user acceptance testing is performed on operational and engineering use cases through the use of the instrument engineering graphical user interface (GUI). In this paper we present the VBI bottom up test plan, procedures, example test cases and tools used, as well as results from test execution in the laboratory. We will also discuss the benefits realized through completion of this testing, and share lessons learned from the bottoms up testing process.

  4. Rocket Propulsion 21 Steering Committee Meeting (RP21) NASA In-Space Propulsion Update

    NASA Technical Reports Server (NTRS)

    Klem, Mark

    2015-01-01

    In-house Support of NEXT-C Contract Status Thruster NEXT Long Duration Test post-test destructive evaluation in progress Findings will be used to verify service life models identify potential design improvements Cathode heater fabrication initiated for cyclic life testing Thruster operating algorithm definition verification initiated to provide operating procedures for mission users High voltage propellant isolator life test voluntarily terminated after successfully operating 51,200 h Power processor unit (PPU) Replaced all problematic stacked multilayer ceramic dual inline pin capacitors within PPU Test bed Rebuilt installed discharge power supply primary power board Completed full functional performance characterization Final test report in progress Transferred PPU Testbed to contractor to support prototype design effort.

  5. Digital avionics systems - Overview of FAA/NASA/industry-wide briefing

    NASA Technical Reports Server (NTRS)

    Larsen, William E.; Carro, Anthony

    1986-01-01

    The effects of incorporating digital technology into the design of aircraft on the airworthiness criteria and certification procedures for aircraft are investigated. FAA research programs aimed at providing data for the functional assessment of aircraft which use digital systems for avionics and flight control functions are discussed. The need to establish testing, assurance assessment, and configuration management technologies to insure the reliability of digital systems is discussed; consideration is given to design verification, system performance/robustness, and validation technology.

  6. Melodic interval perception by normal-hearing listeners and cochlear implant users

    PubMed Central

    Luo, Xin; Masterson, Megan E.; Wu, Ching-Chih

    2014-01-01

    The perception of melodic intervals (sequential pitch differences) is essential to music perception. This study tested melodic interval perception in normal-hearing (NH) listeners and cochlear implant (CI) users. Melodic interval ranking was tested using an adaptive procedure. CI users had slightly higher interval ranking thresholds than NH listeners. Both groups' interval ranking thresholds, although not affected by root note, significantly increased with standard interval size and were higher for descending intervals than for ascending intervals. The pitch direction effect may be due to a procedural artifact or a difference in central processing. In another test, familiar melodies were played with all the intervals scaled by a single factor. Subjects rated how in tune the melodies were and adjusted the scaling factor until the melodies sounded the most in tune. CI users had lower final interval ratings and less change in interval rating as a function of scaling factor than NH listeners. For CI users, the root-mean-square error of the final scaling factors and the width of the interval rating function were significantly correlated with the average ranking threshold for ascending rather than descending intervals, suggesting that CI users may have focused on ascending intervals when rating and adjusting the melodies. PMID:25324084

  7. 40 CFR 92.125 - Pre-test procedures and preconditioning.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Pre-test procedures and... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...

  8. 40 CFR 92.125 - Pre-test procedures and preconditioning.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Pre-test procedures and... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...

  9. 40 CFR 92.125 - Pre-test procedures and preconditioning.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Pre-test procedures and... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...

  10. 40 CFR 92.125 - Pre-test procedures and preconditioning.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Pre-test procedures and... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...

  11. Functional outcomes after shoulder resection: the patient's perspective.

    PubMed

    Stevens, Nicole M; Kim, H Mike; Armstrong, April D

    2015-09-01

    Resection arthroplasty is a salvage procedure used for the treatment of deep-seated infections after total shoulder arthroplasty, hemiarthroplasty, and reverse total shoulder arthroplasty. Previous studies have reported a 50% to 66% rate of pain relief after resection arthroplasty but with significant functional limitations. Our study aimed to qualify the perspective of the patients on their limitations and satisfaction with resection arthroplasty. A retrospective record review of resection arthroplasties performed between September 2003 and December 2012 yielded 14 patients, and 7 completed the survey. The patients completed surveys with the focus on the "patient perspective." Functional scores, including American Shoulder and Elbow Surgeons, Simple Shoulder Test, Disabilities of the Arm, Shoulder, and Hand (DASH), DASH work, and DASH sports, were determined. Pain reduction and functional outcomes were similar to past reports of resection arthroplasty. Five of the 7 patients (71%) reported satisfaction with their resection arthroplasty, and 6 of the 7 patients (86%) would undergo the procedure again if given the choice. Five of the 7 patients (71%) were able to most of activities of daily living. Patients in our study were generally satisfied with their resection arthroplasty. Resection arthroplasty is a reasonable option for treatment of deep-seated periprosthetic infections or for patients with multiple previous failed procedures for total shoulder arthroplasty, hemiarthroplasty. and reverse shoulder arthroplasty. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Effects of handcuffs on neuropsychological testing: Implications for criminal forensic evaluations.

    PubMed

    Biddle, Christine M; Fazio, Rachel L; Dyshniku, Fiona; Denney, Robert L

    2018-01-01

    Neuropsychological evaluations are increasingly performed in forensic contexts, including in criminal settings where security sometimes cannot be compromised to facilitate evaluation according to standardized procedures. Interpretation of nonstandardized assessment results poses significant challenges for the neuropsychologist. Research is limited in regard to the validation of neuropsychological test accommodation and modification practices that deviate from standard test administration; there is no published research regarding the effects of hand restraints upon neuropsychological evaluation results. This study provides preliminary results regarding the impact of restraints on motor functioning and common neuropsychological tests with a motor component. When restrained, performance on nearly all tests utilized was significantly impacted, including Trail Making Test A/B, a coding test, and several tests of motor functioning. Significant performance decline was observed in both raw scores and normative scores. Regression models are also provided in order to help forensic neuropsychologists adjust for the effect of hand restraints on raw scores of these tests, as the hand restraints also resulted in significant differences in normative scores; in the most striking case there was nearly a full standard deviation of discrepancy.

  13. 16 CFR 1610.6 - Test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test procedure. 1610.6 Section 1610.6... FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.6 Test procedure. The test procedure is divided into two... according to paragraph (b)(1) of this section. (a) Step 1—Testing in the original state. (1) Tests shall be...

  14. 16 CFR 1610.6 - Test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Test procedure. 1610.6 Section 1610.6... FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.6 Test procedure. The test procedure is divided into two... according to paragraph (b)(1) of this section. (a) Step 1—Testing in the original state. (1) Tests shall be...

  15. 16 CFR 1610.6 - Test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Test procedure. 1610.6 Section 1610.6... FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.6 Test procedure. The test procedure is divided into two... according to paragraph (b)(1) of this section. (a) Step 1—Testing in the original state. (1) Tests shall be...

  16. Is my bottom-up uncertainty estimation on metal measurement adequate?

    NASA Astrophysics Data System (ADS)

    Marques, J. R.; Faustino, M. G.; Monteiro, L. R.; Ulrich, J. C.; Pires, M. A. F.; Cotrim, M. E. B.

    2018-03-01

    Is the estimated uncertainty under GUM recommendation associated with metal measurement adequately estimated? How to evaluate if the measurement uncertainty really covers all uncertainty that is associated with the analytical procedure? Considering that, many laboratories frequently underestimate or less frequently overestimate uncertainties on its results; this paper presents the evaluation of estimated uncertainties on two ICP-OES procedures of seven metal measurements according to GUM approach. Horwitz function and proficiency tests scaled standard uncertainties were used in this evaluation. Our data shows that most elements expanded uncertainties were from two to four times underestimated. Possible causes and corrections are discussed herein.

  17. Structural Tailoring of Advanced Turboprops (STAT)

    NASA Technical Reports Server (NTRS)

    Brown, Kenneth W.

    1988-01-01

    This interim report describes the progress achieved in the structural Tailoring of Advanced Turboprops (STAT) program which was developed to perform numerical optimizations on highly swept propfan blades. The optimization procedure seeks to minimize an objective function, defined as either direct operating cost or aeroelastic differences between a blade and its scaled model, by tuning internal and external geometry variables that must satisfy realistic blade design constraints. This report provides a detailed description of the input, optimization procedures, approximate analyses and refined analyses, as well as validation test cases for the STAT program. In addition, conclusions and recommendations are summarized.

  18. Effects of a modified technique for TVT-O positioning on postoperative pain: single-blind randomized study.

    PubMed

    Tommaselli, Giovanni A; Formisano, Carmen; Di Carlo, Costantino; Fabozzi, Annamaria; Nappi, Carmine

    2012-09-01

    One of the most frequent and distressing complications of the tension-free vaginal tape obturator (TVT-O) procedure for stress urinary incontinence (SUI) is groin pain, which may be related to the surgical technique or to the tape. The aim of this study was to evaluate the impact of a more limited dissection and a more medial trocar trajectory in TVT-O positioning on postoperative pain. Seventy-two SUI patients were randomized to undergo TVT-O either with the traditional technique (group A) or a modified procedure (reduced paraurethral dissection and a more medial trocar trajectory) (group B). Visual analog scale pain scores 12 h, 24 h, and 1 month after the procedure, number of analgesic vials, objective cure rate, and patient functional and quality of life scores 6 months after the procedure were evaluated. Data were analyzed by the Student's t test for parametric variables, the Mann-Whitney U and Wilcoxon tests for nonparametric variables, and Fisher's exact test for categorical variables. Pain scores were significantly lower in group B compared with group A 24 h after surgery (P = 0.01). Pain scores significantly decreased from 12-24 h postoperatively to 1 month follow-up in both groups (P < 0.001). No significant differences were observed in the number of analgesic vials administered, cure rates, and questionnaire scores between the two groups. More limited dissection and a more medial trocar trajectory of TVT-O seem to reduce postoperative groin pain at 24 h after the procedure, but not the analgesic requirement.

  19. Environmental Control Subsystem Development

    NASA Technical Reports Server (NTRS)

    Laidlaw, Jacob; Zelik, Jonathan

    2017-01-01

    Kennedy Space Center's Launch Pad 39B, part of Launch Complex 39, is currently undergoing construction to prepare it for NASA's Space Launch System missions. The Environmental Control Subsystem, which provides the vehicle with an air or nitrogen gas environment, required development of its local and remote display screens. The remote displays, developed by NASA contractors and previous interns, were developed without complete functionality; the remote displays were revised, adding functionality to over 90 displays. For the local displays, multiple test procedures were developed to assess the functionality of the screens, as well as verify requirements. One local display screen was also developed.

  20. Neural networks for function approximation in nonlinear control

    NASA Technical Reports Server (NTRS)

    Linse, Dennis J.; Stengel, Robert F.

    1990-01-01

    Two neural network architectures are compared with a classical spline interpolation technique for the approximation of functions useful in a nonlinear control system. A standard back-propagation feedforward neural network and a cerebellar model articulation controller (CMAC) neural network are presented, and their results are compared with a B-spline interpolation procedure that is updated using recursive least-squares parameter identification. Each method is able to accurately represent a one-dimensional test function. Tradeoffs between size requirements, speed of operation, and speed of learning indicate that neural networks may be practical for identification and adaptation in a nonlinear control environment.

  1. 40 CFR 63.945 - Test methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Test methods and procedures. 63.945...) National Emission Standards for Surface Impoundments § 63.945 Test methods and procedures. (a) Procedure...) The test shall be conducted in accordance with the procedures specified in Method 21 of 40 CFR part 60...

  2. 77 FR 24341 - Energy Conservation Program: Test Procedures for Residential Clothes Washers; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-24

    ... Program: Test Procedures for Residential Clothes Washers; Correction AGENCY: Office of Energy Efficiency... final rule establishing new and amended test procedures for residential clothes washers, published in... Energy (DOE) erroneously referenced the new test procedure, rather than the currently effective test...

  3. 40 CFR 92.125 - Pre-test procedures and preconditioning.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Pre-test procedures and preconditioning... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.125 Pre-test procedures and preconditioning. (a) Locomotive testing. (1) Determine engine lubricating...

  4. Clinical and functional outcomes after 2 years in the early detection and intervention for the prevention of psychosis multisite effectiveness trial.

    PubMed

    McFarlane, William R; Levin, Bruce; Travis, Lori; Lucas, F Lee; Lynch, Sarah; Verdi, Mary; Williams, Deanna; Adelsheim, Steven; Calkins, Roderick; Carter, Cameron S; Cornblatt, Barbara; Taylor, Stephan F; Auther, Andrea M; McFarland, Bentson; Melton, Ryan; Migliorati, Margaret; Niendam, Tara; Ragland, J Daniel; Sale, Tamara; Salvador, Melina; Spring, Elizabeth

    2015-01-01

    To test effectiveness of the Early Detection, Intervention, and Prevention of Psychosis Program in preventing the onset of severe psychosis and improving functioning in a national sample of at-risk youth. In a risk-based allocation study design, 337 youth (age 12-25) at risk of psychosis were assigned to treatment groups based on severity of positive symptoms. Those at clinically higher risk (CHR) or having an early first episode of psychosis (EFEP) were assigned to receive Family-aided Assertive Community Treatment (FACT); those at clinically lower risk (CLR) were assigned to receive community care. Between-groups differences on outcome variables were adjusted statistically according to regression-discontinuity procedures and evaluated using the Global Test Procedure that combined all symptom and functional measures. A total of 337 young people (mean age: 16.6) were assigned to the treatment group (CHR + EFEP, n = 250) or comparison group (CLR, n = 87). On the primary variable, positive symptoms, after 2 years FACT, were superior to community care (2 df, p < .0001) for both CHR (p = .0034) and EFEP (p < .0001) subgroups. Rates of conversion (6.3% CHR vs 2.3% CLR) and first negative event (25% CHR vs 22% CLR) were low but did not differ. FACT was superior in the Global Test (p = .0007; p = .024 for CHR and p = .0002 for EFEP, vs CLR) and in improvement in participation in work and school (p = .025). FACT is effective in improving positive, negative, disorganized and general symptoms, Global Assessment of Functioning, work and school participation and global outcome in youth at risk for, or experiencing very early, psychosis. © The Author 2014. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center.

  5. Brain lateralization and neural plasticity for musical and cognitive abilities in an epileptic musician

    PubMed Central

    Trujillo-Pozo, Isabel; Martín-Monzón, Isabel; Rodríguez-Romero, Rafael

    2013-01-01

    The use of intracarotid propofol procedure (IPP) when assessing musical lateralization has not been reported in literature up to now. This procedure (similar to Wada Test) has provided the opportunity to investigate not only lateralization of language and memory functions on epileptic patients but also offers a functional mapping approach with superior spatial and temporal resolution to analyze the lateralization of musical abilities. Findings in literature suggest that musical training modifies functional and structural brain organization. We studied hemispheric lateralization in a professional musician, a 33 years old woman with refractory left medial temporal lobe (MTL) epilepsy (TLE). A longitudinal neuropsychological study was performed over a period of 21 months. Before epilepsy surgery, musical abilities, language and memory were tested during IPP by means of a novel and exhaustive neuropsychological battery focusing on the processing of music. We used a selection of stimuli to analyze listening, score reading, and tempo discrimination. Our results suggested that IPP is an excellent method to determine not only language, semantic, and episodic memory, but also musical dominance in a professional musician who may be candidate for epilepsy surgery. Neuropsychological testing revealed that right hemisphere's patient is involved in semantic and episodic musical memory processes, whereas her score reading and tempo processing require contribution from both hemispheres. At one-year follow-up, outcome was excellent with respect to seizures and professional skills, meanwhile cognitive abilities improved. These findings indicate that IPP helps to predict who might be at risk for postoperative musical, language, and memory deficits after epilepsy surgery. Our research suggests that musical expertise and epilepsy critically modifies long-term memory processes and induces brain structural and functional plasticity. PMID:24367312

  6. Initial clinical experience with a novel biodegradable ring in patients with functional tricuspid insufficiency: Kalangos Biodegradable Tricuspid Ring.

    PubMed

    Burma, O; Ustunsoy, H; Davutoglu, V; Celkan, M A; Kazaz, H; Pektok, E

    2007-08-01

    Tricuspid annuloplasty procedures have been widely performed in clinics for many years. The Kalangos Biodegradable Tricuspid Ring (Kalangos Biodegradable Tricuspid Ring, Bioring SA, Lonay, Switzerland) is a novel prosthesis for the treatment of tricuspid insufficiency. The aim of this study was to evaluate the clinical and echocardiographic results of this novel prosthesis for functional tricuspid insufficiency. Between October 2005 and May 2006, 15 patients with the diagnosis of moderate or severe functional tricuspid insufficiency were treated by implantation of a Kalangos Biodegradable Tricuspid Ring. All patients were evaluated clinically and by echocardiography preoperatively, and control tests were performed at the end of the 1st and 6th month following surgery. Moderate and severe insufficiency was documented in 11 and 4 patients, respectively, in the preoperative tests. 1 and 6 months after surgery, 4 patients had trace and 1 patient had mild tricuspid insufficiency, while 10 patients had none. At the 1st and 6th month follow-up, systolic pulmonary arterial pressure, right atrial dimension and right ventricular diastolic diameter were found to be significantly lower than the preoperative values ( P < 0.0001). The right atrial diameter and tricuspid valve area had decreased significantly at the end of the 1st month; however, no significant difference was found between the 1st and 6th month tests ( P > 0.05). Three-quarters of the annuloplasty ring had degraded at 6 months. No complications related to the prosthesis or the procedure occurred within this period. Kalangos Biodegradable Ring is a promising prosthesis in patients with functional tricuspid insufficiency, with encouraging initial results.

  7. A procedure of landscape services assessment based on mosaics of patches and boundaries.

    PubMed

    Martín de Agar, Pilar; Ortega, Marta; de Pablo, Carlos L

    2016-09-15

    We develop a procedure for assessing the environmental value of landscape mosaics that simultaneously considers the values of land use patches and the values of the boundaries between them. These boundaries indicate the ecological interactions between the patches. A landscape mosaic is defined as a set of patches and the boundaries between them and corresponds to a spatial pattern of ecological interactions. The procedure is performed in two steps: (i) an environmental assessment of land use patches by means of a function that integrates values based on the goods and services the patches provide, and (ii) an environmental valuation of mosaics using a function that integrates the environmental values of their patches and the types and frequencies of the boundaries between them. This procedure allows us to measure how changes in land uses or in their spatial arrangement cause variations in the environmental value of landscape mosaics and therefore in that of the whole landscape. The procedure was tested in the Sierra Norte of Madrid (central Spain). The results show that the environmental values of the landscape depend not only on the land use patches but also on the values associated with the pattern of the boundaries within the mosaics. The results also highlight the importance of the boundaries between land use patches as determinants of the goods and services provided by the landscape. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. One normal void and residual following MUS surgery is all that is necessary in most patients.

    PubMed

    Ballard, Paul; Shawer, Sami; Anderson, Colette; Khunda, Aethele

    2018-04-01

    There is considerable variation worldwide on how the assessment of voiding function is performed following midurethral sling (MUS) surgery. There is potentially a financial cost, and reduction in efficiency when patient discharge is delayed. Using our current practice of two normal void and residual (V&R) readings before discharge, the aim of this retrospective study was to evaluate the likelihood of an abnormal second V&R test if the first V&R test was normal in order to determine if a policy of discharge after only one satisfactory V&R test is reasonable. Data from 400 patients who had had MUS surgery with or without other procedures were collected. Our unit protocol included two consecutive voids of greater than 200 ml with residuals less than 150 ml before discharge. The patients were divided into the following groups: MUS only, MUS plus anterior colporrhaphy (AR) plus any other procedures (MUS/AR), and MUS with any non-AR procedures (MUS+). Complete datasets were available for 335 patients. Once inadequate tests (low volume voids <200 ml) had been excluded (28% overall), the likelihood of an abnormal second V&R test if the first test was normal was 7.1% overall, but 3.6% for MUS, 11.5% for MUS/AR and 8.6% for MUS+. The findings in the MUS-only group indicate that it is probably safe to discharge patients after one satisfactory V&R test, as long as safety measures such as 'open access' are available so that patients have unhindered readmission if problems arise.

  9. The minimal ice water caloric test compared with established vestibular caloric test procedures.

    PubMed

    Schmäl, Frank; Lübben, Björn; Weiberg, Kerstin; Stoll, Wolfgang

    2005-01-01

    Caloric testing of the vestibular labyrinth is usually performed by classical caloric test procedures (CCTP) using water warmed to 30 degrees C and 44 degrees C. Ice water irrigation (4 degrees C) is usually not performed, although it might be useful as a bedside test. To verify the validity of the Minimal Ice Water Caloric Test (MIWCT), comparative video-oculographic investigations were performed in 22 healthy subjects using ice water (0.5 ml, 1.0 ml, 2 ml), CCTP, and cold air (27 degrees C). Frequency, amplitude, slow phase velocity (SPV), the onset, and the duration of nystagmus were documented. After addition of three ice cubes, the temperature of conventional tap water (16 degrees C) fell within 13 min to 4 degrees C. In pessimum position the subjects demonstrated no nystagmus response. Compared to CCTP, MIWCT was associated with a significantly later onset of nystagmus and a significant prolongation of the nystagmus reaction. In contrast to air stimulation (27 degrees C), a significant Spearman's correlation was noted between MIWCT (1 and 2 ml) and established CCTP in respect of essential nystagmus parameters (frequency, amplitude and SPV). Furthermore, MIWCT (0.5 and 1 ml) showed a higher sensitivity and specificity with regard to the detection of canal paresis based on Jongkees' formula compared to stimulation with air 27 degrees C. Thus, MIWCT appears to be a suitable procedure for bedside investigation of vestibular function outside the vestibular laboratory, e.g. in a hospital ward, where bedridden patients with vertigo occasionally require vestibular testing.

  10. 40 CFR 1066.840 - Highway fuel economy test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Highway fuel economy test procedure... Highway fuel economy test procedure. This section describes the procedure for the highway fuel economy test (HFET). This test involves emission sampling and fuel economy measurement for certain vehicles as...

  11. 76 FR 65631 - Energy Conservation Program: Test Procedures for Microwave Ovens

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-24

    ... Conservation Program: Test Procedures for Microwave Ovens AGENCY: Office of Energy Efficiency and Renewable... (DOE) has initiated a test procedure rulemaking to develop active mode testing methodologies for... Federal Register a final rule for the microwave oven test procedure rulemaking (July TP repeal final rule...

  12. 78 FR 63823 - Energy Conservation Program: Test Procedures for Television Sets

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... Conservation Program: Test Procedures for Television Sets AGENCY: Office of Energy Efficiency and Renewable... Energy (DOE) issued a notice of proposed rulemaking (NOPR) to establish a new test procedure for... additional testing and proposed amendments to the TV test procedure in its March 12, 2013 supplemental notice...

  13. 78 FR 38455 - Energy Conservation Program: Test Procedures for Electric Motors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-26

    ... Conservation Program: Test Procedures for Electric Motors; Proposed Rule #0;#0;Federal Register / Vol. 78, No... 431 [Docket No. EERE-2012-BT-TP-0043] RIN 1904-AC89 Energy Conservation Program: Test Procedures for... establishing definitions, specifying testing set-up procedures necessary to test, and extending DOE's existing...

  14. 76 FR 50145 - Energy Conservation Program: Test Procedures for Residential Clothes Dryers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-12

    ... EERE-2011-BT-TP-0054] RIN 1904-AC63 Energy Conservation Program: Test Procedures for Residential...: Request for information. SUMMARY: The U.S. Department of Energy (DOE) has initiated a test procedure... clothes dryer test procedure. DOE will address the issues surrounding testing of automatic cycle...

  15. 78 FR 62488 - Energy Conservation Program: Compliance Date for the Dehumidifier Test Procedure

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... Conservation Program: Compliance Date for the Dehumidifier Test Procedure AGENCY: Office of Energy Efficiency.... Department of Energy (DOE) proposes to revise the compliance date for the dehumidifier test procedures... manufacturers to test using only the active mode provisions in the test procedure for dehumidifiers currently...

  16. 40 CFR 61.304 - Test methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Test methods and procedures. 61.304... Emissions From Benzene Transfer Operations § 61.304 Test methods and procedures. (a) The procedures for... testing equipment shall be prepared and installed as specified in the appropriate test methods. (2) The...

  17. 40 CFR 61.304 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Test methods and procedures. 61.304... Emissions From Benzene Transfer Operations § 61.304 Test methods and procedures. (a) The procedures for... testing equipment shall be prepared and installed as specified in the appropriate test methods. (2) The...

  18. 40 CFR 61.304 - Test methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Test methods and procedures. 61.304... Emissions From Benzene Transfer Operations § 61.304 Test methods and procedures. (a) The procedures for... testing equipment shall be prepared and installed as specified in the appropriate test methods. (2) The...

  19. 40 CFR 61.304 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Test methods and procedures. 61.304... Emissions From Benzene Transfer Operations § 61.304 Test methods and procedures. (a) The procedures for... testing equipment shall be prepared and installed as specified in the appropriate test methods. (2) The...

  20. 40 CFR 61.304 - Test methods and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Test methods and procedures. 61.304... Emissions From Benzene Transfer Operations § 61.304 Test methods and procedures. (a) The procedures for... testing equipment shall be prepared and installed as specified in the appropriate test methods. (2) The...

  1. 40 CFR 86.1227-96 - Test procedures; overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Test procedures; overview. 86.1227-96... Emission Test Procedures for New Gasoline-Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.1227-96 Test procedures; overview. (a) The overall test consists...

  2. Statistical correlation of structural mode shapes from test measurements and NASTRAN analytical values

    NASA Technical Reports Server (NTRS)

    Purves, L.; Strang, R. F.; Dube, M. P.; Alea, P.; Ferragut, N.; Hershfeld, D.

    1983-01-01

    The software and procedures of a system of programs used to generate a report of the statistical correlation between NASTRAN modal analysis results and physical tests results from modal surveys are described. Topics discussed include: a mathematical description of statistical correlation, a user's guide for generating a statistical correlation report, a programmer's guide describing the organization and functions of individual programs leading to a statistical correlation report, and a set of examples including complete listings of programs, and input and output data.

  3. High-level neutron coincidence counter maintenance manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included.

  4. A Procedure to Detect Item Bias Present Simultaneously in Several Items

    DTIC Science & Technology

    1991-04-25

    exhibit a coherent and major biasing influence at the test level. In partic- ular, this can be true even if each individual item displays only a minor...response functions (IRFs) without the use of item parameter estimation algorithms when the sample size is too small for their use. Thissen, Steinberg...convention). A random sample of examinees is drawn from each group, and a test of N items is administered to them. Typically it is suspected that a

  5. 40 CFR 90.411 - Post-test analyzer procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...

  6. 40 CFR 90.411 - Post-test analyzer procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...

  7. 40 CFR 90.411 - Post-test analyzer procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...

  8. 40 CFR 90.411 - Post-test analyzer procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...

  9. 40 CFR 90.411 - Post-test analyzer procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Post-test analyzer procedures. 90.411... Test Procedures § 90.411 Post-test analyzer procedures. (a) Perform a HC hang-up check within 60...), the test is void. (d) Read and record the post-test data specified in § 90.405(e). (e) For a valid...

  10. Sexing California Clapper Rails using morphological measurements

    USGS Publications Warehouse

    Overton, Cory T.; Casazza, Michael L.; Takekawa, John Y.; Rohmer, Tobias M.

    2009-01-01

    California Clapper Rails (Rallus longirostris obsoletus) have monomorphic plumage, a trait that makes identification of sex difficult without extensive behavioral observation or genetic testing. Using 31 Clapper Rails (22 females, 9 males), caught in south San Francisco Bay, CA, and using easily measurable morphological characteristics, we developed a discriminant function to distinguish sex. We then validated this function on 33 additional rails. Seven morphological measurements were considered, resulting in three which were selected in the discriminate function: culmen length, tarsometatarsus length, and flat wing length. We had no classification errors for the development or testing datasets either with resubstitution or cross-validation procedures. Male California Clapper Rails were 6-22% larger than females for individual morphological traits, and the largest difference was in body mass.  Variables in our discriminant function closely match variables developed for sexing Clapper Rails of Gulf Coast populations. However, a universal discriminant function to sex all Clapper Rail subspecies is not likely because of large and inconsistent differences in morphological traits among subspecies. 

  11. The Role of Context in the Categorization of Hybrid Toy Stimuli by 18-Month-Olds

    ERIC Educational Resources Information Center

    Mareschal, Denis; Tan, Seok Hui

    2008-01-01

    Using a sequential touching procedure, we examined whether 18-month-olds could use different categorization strategies adaptively as a function of context. Infants were presented with test toys of land animals (quadrupeds), cars, and hybrids made by recombining car parts with animal parts. Infants who experienced a context emphasizing a taxonomic…

  12. 49 CFR 40.25 - Must an employer check on the drug and alcohol testing record of employees it is intending to use...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL..., you must, after obtaining an employee's written consent, request the information about the employee... the employee to perform safety-sensitive functions. (b) You must request the information listed in...

  13. Response Latency as a Function of Hypothesis-Testing Strategies in Concept Identification

    ERIC Educational Resources Information Center

    Fink, Richard T.

    1972-01-01

    The ability of M. Levine's subset-sampling assumptions to account for the decrease in response latency following the trial of the last error was investigated by employing a distributed stimulus set composed of four binary dimensions and a procedure which required Ss to make an overt response in order to sample each dimension. (Author)

  14. Squared Euclidean distance: a statistical test to evaluate plant community change

    Treesearch

    Raymond D. Ratliff; Sylvia R. Mori

    1993-01-01

    The concepts and a procedure for evaluating plant community change using the squared Euclidean distance (SED) resemblance function are described. Analyses are based on the concept that Euclidean distances constitute a sample from a population of distances between sampling units (SUs) for a specific number of times and SUs. With different times, the distances will be...

  15. Conceptual design and feasibility evaluation model of a 10 to the 8th power bit oligatomic mass memory. Volume 3: Operation manual

    NASA Technical Reports Server (NTRS)

    Horst, R. L.; Nordstrom, M. J.

    1972-01-01

    An operation manual is presented for the oligatomic mass memory feasibility model. It includes a brief description of the memory and exerciser units, a description of the controls and their functions, the operating procedures, the test points and adjustments, and the circuit diagram.

  16. Techniques for recognizing identity of several response functions from the data of visual inspection

    NASA Astrophysics Data System (ADS)

    Nechval, Nicholas A.

    1996-08-01

    The purpose of this paper is to present some efficient techniques for recognizing from the observed data whether several response functions are identical to each other. For example, in an industrial setting the problem may be to determine whether the production coefficients established in a small-scale pilot study apply to each of several large- scale production facilities. The techniques proposed here combine sensor information from automated visual inspection of manufactured products which is carried out by means of pixel-by-pixel comparison of the sensed image of the product to be inspected with some reference pattern (or image). Let (a1, . . . , am) be p-dimensional parameters associated with m response models of the same type. This study is concerned with the simultaneous comparison of a1, . . . , am. A generalized maximum likelihood ratio (GMLR) test is derived for testing equality of these parameters, where each of the parameters represents a corresponding vector of regression coefficients. The GMLR test reduces to an equivalent test based on a statistic that has an F distribution. The main advantage of the test lies in its relative simplicity and the ease with which it can be applied. Another interesting test for the same problem is an application of Fisher's method of combining independent test statistics which can be considered as a parallel procedure to the GMLR test. The combination of independent test statistics does not appear to have been used very much in applied statistics. There does, however, seem to be potential data analytic value in techniques for combining distributional assessments in relation to statistically independent samples which are of joint experimental relevance. In addition, a new iterated test for the problem defined above is presented. A rejection of the null hypothesis by this test provides some reason why all the parameters are not equal. A numerical example is discussed in the context of the proposed procedures for hypothesis testing.

  17. A Quantitative Review of Functional Analysis Procedures in Public School Settings

    ERIC Educational Resources Information Center

    Solnick, Mark D.; Ardoin, Scott P.

    2010-01-01

    Functional behavioral assessments can consist of indirect, descriptive and experimental procedures, such as a functional analysis. Although the research contains numerous examples demonstrating the effectiveness of functional analysis procedures, experimental conditions are often difficult to implement in classroom settings and analog conditions…

  18. ωB97X-V: A 10-parameter, range-separated hybrid, generalized gradient approximation density functional with nonlocal correlation, designed by a survival-of-the-fittest strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mardirossian, Narbe; Head-Gordon, Martin

    2013-12-18

    A 10-parameter, range-separated hybrid (RSH), generalized gradient approximation (GGA) density functional with nonlocal correlation (VV10) is presented in this paper. Instead of truncating the B97-type power series inhomogeneity correction factors (ICF) for the exchange, same-spin correlation, and opposite-spin correlation functionals uniformly, all 16 383 combinations of the linear parameters up to fourth order (m = 4) are considered. These functionals are individually fit to a training set and the resulting parameters are validated on a primary test set in order to identify the 3 optimal ICF expansions. Through this procedure, it is discovered that the functional that performs best onmore » the training and primary test sets has 7 linear parameters, with 3 additional nonlinear parameters from range-separation and nonlocal correlation. The resulting density functional, ωB97X-V, is further assessed on a secondary test set, the parallel-displaced coronene dimer, as well as several geometry datasets. Finally and furthermore, the basis set dependence and integration grid sensitivity of ωB97X-V are analyzed and documented in order to facilitate the use of the functional.« less

  19. Lung imaging in pulmonary disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taplin, G.V.; Chopra, S.K.

    1976-01-01

    Although it has been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as a means of distinguishing pulmonary embolism (P.E.) from COPD is reported. Recent experience is reported with the use of both of these procedures in comparison with pulmonary function tests for the early detection of COPD in population studies and also in P.E. suspects. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imagingmore » in the differential diagnosis of P.E. Finally, this paper is concerned with new developments in regional lung diffusion imaging following the inhalation of radioactive gases and rapidly absorbed radioaerosols. Their experimental basis is presented and their potential clinical applications in pulmonary embolism are discussed. As a result of these investigations, a functional (V/P) diagnosis of pulmonary embolism in patients may be possible in the near future with a sequential radioaerosol inhalation procedure alone.« less

  20. Thoracoscopic laser pneumoplasty in the treatment of diffuse bullous emphysema.

    PubMed

    Wakabayashi, A

    1995-10-01

    Thoracoscopic laser pneumoplasty in the treatment of diffuse bullous emphysema by means of a contact neodymium:yttrium-aluminum garnet laser was evaluated by a retrospective analysis of the first consecutive 500 procedures in 443 patients. The indication for thoracoscopic laser pneumoplasty was intractable dyspnea. Advanced age (mean age, 67 years), high oxygen dependency (70%), steroid use (46%), and markedly diminished physical capacity (2% bedridden and 27% wheelchair-bound) were noted. Thoracoscopic laser pneumoplasty was carried out under general anesthesia and one-lung ventilation. Type 3 bullae (381 procedures) were contracted by contact neodymium:yttrium-aluminum garnet laser and type 4 bullae (199 procedures) excised. The operative mortality rate was 4.8%. Subjective improvement was reported by 87% of the patients. Follow-up functional evaluation was available in 229 patients, which showed highly significant improvement. A comparison of preoperative and postoperative functional tests between type 3 and 4 bullae patients showed no significant difference, except the latter had higher decrease in airway resistance, residual volume, and total lung capacity. Thoracoscopic laser pneumoplasty is an effective treatment for both type 3 and 4 bullous emphysema with an acceptable risk.

  1. Preharvest food safety.

    PubMed

    Childers, A B; Walsh, B

    1996-07-23

    Preharvest food safety is essential for the protection of our food supply. The production and transport of livestock and poultry play an integral part in the safety of these food products. The goals of this safety assurance include freedom from pathogenic microorganisms, disease, and parasites, and from potentially harmful residues and physical hazards. Its functions should be based on hazard analysis and critical control points from producer to slaughter plant with emphasis on prevention of identifiable hazards rather than on removal of contaminated products. The production goal is to minimize infection and insure freedom from potentially harmful residues and physical hazards. The marketing goal is control of exposure to pathogens and stress. Both groups should have functional hazard analysis and critical control points management programs which include personnel training and certification of producers. These programs must cover production procedures, chemical usage, feeding, treatment practices, drug usage, assembly and transportation, and animal identification. Plans must use risk assessment principles, and the procedures must be defined. Other elements would include preslaughter certification, environmental protection, control of chemical hazards, live-animal drug-testing procedures, and identification of physical hazards.

  2. Minimization of a Class of Matrix Trace Functions by Means of Refined Majorization.

    ERIC Educational Resources Information Center

    Kiers, Henk A. L.; ten Berge, Jos M. F.

    1992-01-01

    A procedure is described for minimizing a class of matrix trace functions, which is a refinement of an earlier procedure for minimizing the class of matrix trace functions using majorization. Several trial analyses demonstrate that the revised procedure is more efficient than the earlier majorization-based procedure. (SLD)

  3. 40 CFR 60.675 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Test methods and procedures. 60.675... Mineral Processing Plants § 60.675 Test methods and procedures. (a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in...

  4. 40 CFR 60.644 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Test methods and procedures. 60.644... Gas Processing: SO2 Emissions § 60.644 Test methods and procedures. (a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test...

  5. 14 CFR Appendix F to Part 23 - Test Procedure

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Test Procedure F Appendix F to Part 23...—Test Procedure Acceptable test procedure for self-extinguishing materials for showing compliance with... as sandwich panels, may not be separated for a test. The specimen thickness must be no thicker than...

  6. 40 CFR 94.109 - Test procedures for Category 3 marine engines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Test procedures for Category 3 marine... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE COMPRESSION-IGNITION ENGINES Test Procedures § 94.109 Test procedures for Category 3 marine engines. (a) Gaseous emissions shall be measured using the test...

  7. 40 CFR 94.109 - Test procedures for Category 3 marine engines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Test procedures for Category 3 marine... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM MARINE COMPRESSION-IGNITION ENGINES Test Procedures § 94.109 Test procedures for Category 3 marine engines. (a) Gaseous emissions shall be measured using the test...

  8. 40 CFR 60.503 - Test methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Test methods and procedures. 60.503... Terminals § 60.503 Test methods and procedures. (a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of...

  9. 40 CFR 60.503 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Test methods and procedures. 60.503... Terminals § 60.503 Test methods and procedures. (a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of...

  10. 40 CFR 60.503 - Test methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Test methods and procedures. 60.503... Terminals § 60.503 Test methods and procedures. (a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of...

  11. 40 CFR 60.503 - Test methods and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Test methods and procedures. 60.503... Terminals § 60.503 Test methods and procedures. (a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of...

  12. 40 CFR 60.503 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Test methods and procedures. 60.503... Terminals § 60.503 Test methods and procedures. (a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of...

  13. Pre-operative endoscopic ultrasonography can optimise the management of patients undergoing laparoscopic cholecystectomy with abnormal liver function tests as the sole risk factor for choledocholithiasis: a prospective study.

    PubMed

    Meroni, E; Bisagni, P; Bona, S; Fumagalli, U; Zago, M; Rosati, R; Malesci, A

    2004-01-01

    Pre-operative endosonography has been proposed as a cost-effective procedure in the management of patients who undergo laparoscopic cholecystectomy having an intermediate risk of common bile duct stones. We prospectively evaluated the impact of pre-operative endosonography on the management of patients facing laparoscopic cholecystectomy with abnormal liver function tests as the sole risk factor for choledocolithiasis. Among 587 consecutive patients scheduled for laparoscopic cholecystectomy, 47 (8%) patients having one or more abnormal liver function tests but a normal appearance of common bile duct at abdominal ultrasound, underwent pre-operative endosonography. In patients with endosonography-detected common bile duct stones, a pre-operative endoscopic retrograde cholangiography was performed, or an intra-operative endoscopic retrograde cholangiography was scheduled. In all endosonography-negative patients, an intra-operative trans-cystic cholangiography was performed. Endosonography detected common bile duct stones in nine patients (19%) but only in five of them stones were radiologically confirmed (PPV 0.55). Endosonography-detected stones were confirmed in four of four (100%) patients in whom cholangiography was performed within 1 week, but only in one of five (20%) patients in whom radiology was further delayed (P < 0.05). In three of four cases (75%), stones detected at endosonography but not confirmed at X-rays, were smaller than 2.0 mm. Among 38 patients with negative endosonography, common bile duct stones were found in two patients (NPV 0.95), whereas unplanned endoscopic stone extraction was needed only in one patient (NPV 0.97). Pre-operative endosonography can spare unnecessary pre-operative endoscopic retrograde cholangiography as well as inappropriate scheduling of intra-operative endoscopic retrograde cholangiography in patients undergoing laparoscopic cholecystectomy with abnormal liver function tests. To maximise the impact of endosonography on the management of these patients, the procedure should be performed immediately before laparoscopic cholecystectomy.

  14. 77 FR 65941 - Energy Conservation Program: Test Procedures for Residential Dishwashers, Dehumidifiers, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-31

    ...The U.S. Department of Energy (DOE) establishes new test procedures for residential dishwashers and dehumidifiers, and amends the currently applicable test procedure for conventional cooking products under the Energy Policy and Conservation Act. The new test procedures include provisions for measuring standby mode and off mode energy consumption, and update the provisions for measuring active mode energy consumption and, for dishwashers, water consumption. This final rule also amends the certification, compliance, and enforcement requirements for dishwashers, dehumidifiers and conventional cooking products, amends certain provisions in the currently applicable dishwasher test procedure, and eliminates an obsolete energy efficiency metric in the dishwasher test procedure and provisions in the cooking products test procedure that have become obsolete due to the elimination of standing pilot lights.

  15. Rapid recovery of high content phytosterols from corn silk.

    PubMed

    Zhang, Haiyan; Cao, Xiaowan; Liu, Yong; Shang, Fude

    2017-10-18

    Phytosterols have important physiological and officinal function. An efficient ultrasonic assisted extraction, purification and crystallization procedure of phytosterols was established from corn silk for the first time. The orthogonal test was applied to optimize the process parameters and a maximum phytosterols recovery as high as 10.5886 mg/g was achieved by ultrasonic treatment for 55 min with liquid-solid ratio of 12:1 at 35 °C, 220 w. The ultrasonic extraction temperature (T, °C) has the most significant effect on extraction yield of phytosterols. An orthogonal crystallization test was performed and the optimal conditions [crystallization temperature of 8 °C, time of 12 h and solid-liquid ratio of 1:1 (g/ml)] afforded maximum phytosterols purity of 92.76 ± 0.43%. An efficient extraction and crystallization procedure was established.

  16. New robust statistical procedures for the polytomous logistic regression models.

    PubMed

    Castilla, Elena; Ghosh, Abhik; Martin, Nirian; Pardo, Leandro

    2018-05-17

    This article derives a new family of estimators, namely the minimum density power divergence estimators, as a robust generalization of the maximum likelihood estimator for the polytomous logistic regression model. Based on these estimators, a family of Wald-type test statistics for linear hypotheses is introduced. Robustness properties of both the proposed estimators and the test statistics are theoretically studied through the classical influence function analysis. Appropriate real life examples are presented to justify the requirement of suitable robust statistical procedures in place of the likelihood based inference for the polytomous logistic regression model. The validity of the theoretical results established in the article are further confirmed empirically through suitable simulation studies. Finally, an approach for the data-driven selection of the robustness tuning parameter is proposed with empirical justifications. © 2018, The International Biometric Society.

  17. 16 CFR § 1610.6 - Test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Test procedure. § 1610.6 Section § 1610.6... FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.6 Test procedure. The test procedure is divided into two... according to paragraph (b)(1) of this section. (a) Step 1—Testing in the original state. (1) Tests shall be...

  18. The emergence of autoclitic frames in atypically and typically developing children as a function of multiple exemplar instruction.

    PubMed

    Luke, Nicole; Greer, R Douglas; Singer-Dudek, Jessica; Keohane, Dolleen-Day

    2011-01-01

    In two experiments, we tested the effect of multiple exemplar instruction (MEI) for training sets on the emergence of autoclitic frames for spatial relations for novel tacts and mands. In Experiment 1, we used a replicated pre- and post-intervention probe design with four students with significant learning disabilities to test for acquisition of four autoclitic frames with novel tacts and mands before and after MEI. The untaught topographies emerged for all participants. In Experiment 2, we used a multiple probe design to test the effects of the MEI procedures on the same responses in four typically developing, bilingual students. The novel usage emerged for all participants. In the latter experiment, the children demonstrated untaught usage of mand or tact frames regardless of whether they were taught to respond in either listener or speaker functions alone or across listener and speaker functions. The findings are discussed in terms of the role of MEI in the formation of abstractions.

  19. 5-inch-size liquid crystal flat panel display evaluation test by flight simulator

    NASA Astrophysics Data System (ADS)

    Kawahara, Hiroyasu; Watanabe, Akira; Wakairo, Kaoru; Udagawa, Tomoyuki; Kurihara, Yoichiro

    An evaluation test is conducted on the function, performance, and display format of a 5x5 inch flat panel display (FPD) in a flight simulator. The FPD utilizes a color liquid crystal panel that is compact and lightweight and has excellent visibility. The simulator evaluation test is carried out in sequence with the conventional takeoff and landing to altitude, and then conversion to STOL procedures for flight path and subsequent approach and landing. It is shown that the liquid crystal display could be employed as a satisfactory indicator for aircraft instrumentation.

  20. Pyrotechnic hazards classification and evaluation program. Phase 3, segments 1-4: Investigation of sensitivity test methods and procedures for pyrotechnic hazards evaluation and classification, part A

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The findings, conclusions, and recommendations relative to the investigations conducted to evaluate tests for classifying pyrotechnic materials and end items as to their hazard potential are presented. Information required to establish an applicable means of determining the potential hazards of pyrotechnics is described. Hazard evaluations are based on the peak overpressure or impulse resulting from the explosion as a function of distance from the source. Other hazard classification tests include dust ignition sensitivity, impact ignition sensitivity, spark ignition sensitivity, and differential thermal analysis.

Top