Sample records for functionally graded rotating

  1. Free Vibration Characteristics of Functionally Graded Pre-twisted Conical Shells under Rotation

    NASA Astrophysics Data System (ADS)

    Das, Apurba; Karmakar, Amit

    2017-06-01

    This article deals with effect of rotation and pretwist angle on free vibration characteristics of functionally graded conical shells. The dynamic equilibrium equation is derived from Lagrange's equation neglecting the Coriolis effect for moderate rotational speeds. The materials properties of conical shell are varied with a power-law distribution of the volume fractions of their constituents through its thickness. Convergence studies are performed in respect of mesh sizes, and comparisons of the present solutions and those reported in open literature are provided to substantiate the accuracy of the proposed method. Computer codes developed to obtain the numerical results for the combined effects of twist angle and rotational speed on the natural frequencies of functionally graded conical shells. The mode shapes for a typical laminate configuration under different conditions are also illustrated. Numerical results are obtained for the non-dimensional fundamental (NDFF) and second frequencies (NDSF).

  2. Graded-index fibers, Wigner-distribution functions, and the fractional Fourier transform.

    PubMed

    Mendlovic, D; Ozaktas, H M; Lohmann, A W

    1994-09-10

    Two definitions of a fractional Fourier transform have been proposed previously. One is based on the propagation of a wave field through a graded-index medium, and the other is based on rotating a function's Wigner distribution. It is shown that both definitions are equivalent. An important result of this equivalency is that the Wigner distribution of a wave field rotates as the wave field propagates through a quadratic graded-index medium. The relation with ray-optics phase space is discussed.

  3. Ultrasound and Functional Assessment of Transtendinous Repairs of Partial-Thickness Articular-Sided Rotator Cuff Tears.

    PubMed

    Ostrander, Roger V; Klauser, Jeffrey M; Menon, Sanjay; Hackel, Joshua G

    2017-03-01

    Partial-thickness articular-sided rotator cuff tears are a frequent source of shoulder pain. Despite conservative measures, some patients continue to be symptomatic and require surgical management. However, there is some controversy as to which surgical approach results in the best outcomes for grade 3 tears. The purpose of this study was to evaluate repair integrity and the clinical results of patients treated with transtendinous repair of high-grade partial-thickness articular-sided rotator cuff tears. Our hypothesis was that transtendinous repairs would result in reliable healing and acceptable functional outcomes. Case series; Level of evidence, 4. Twenty patients with a minimum follow-up of 2 years were included in the study. All patients underwent arthroscopic repair of high-grade partial-thickness rotator cuff tears utilizing a transtendinous technique by a single surgeon. At latest follow-up, the repair integrity was evaluated using ultrasound imaging, and functional scores were calculated. Ultrasound evaluation demonstrated that 18 of 20 patients had complete healing with a normal-appearing rotator cuff. Two patients had a minor residual partial tear. Sixteen of 20 patients had no pain on visual analog scale. Four patients complained of mild intermittent residual pain. All patients were rated as "excellent" by both the University of California at Los Angeles Shoulder Score and the Simple Shoulder Test. The transtendon technique for the repair of articular-sided high-grade partial rotator cuff tears results in reliable tendon healing and excellent functional outcomes.

  4. Modified L'Episcopo tendon transfers for irreparable rotator cuff tears: 5-year follow-up.

    PubMed

    Gerhardt, Christian; Lehmann, Lars; Lichtenberg, Sven; Magosch, Peter; Habermeyer, Peter

    2010-06-01

    Patients with posterosuperior cuff tears lose functional external rotation of the shoulder. Latissimus dorsi and teres major transfer is performed to restore external rotation. Twenty patients with a mean age was 55.8 +/- 6 years underwent this procedure and were examined at averages of 24.7 (n = 17) and 70.6 (n = 13) months. Two patients did not improve presumably because of failure of the transfer. The Constant and Murley score increased from 55.6 to 90.4 after 2 years and to 87.9 after 5 years. The mean active flexion increased from 119.4 degrees to 169.3 degrees and reached 170 degrees after 5 years, and mean external rotation increased from 12 degrees to 35 degrees , finally reaching 23 degrees . The grade of cuff arthritis progressed from initially Grade 1 in 17% and Grade 2 in 28% to Grade 2 in 8%, Grade 3 in 69%, and Grade 4 in 15% at final followup. The acromiohumeral distance increased from 4.5 mm to 6 mm and decreased to 3.8 mm after 5 years. Electromyographic analysis showed activity during isometric internal and external rotation in the transferred muscle in all patients. The L'Episcopo procedure can restore shoulder function, but cuff arthropathy may progress. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  5. Arthroscopic repair of partial-thickness and small full-thickness rotator cuff tears: tendon quality as a prognostic factor for repair integrity.

    PubMed

    Chung, Seok Won; Kim, Jae Yoon; Yoon, Jong Pil; Lyu, Seong Hwa; Rhee, Sung Min; Oh, Se Bong

    2015-03-01

    The healing failure rate is high for partial-thickness or small full-thickness rotator cuff tears. To retrospectively evaluate and compare outcomes after arthroscopic repair of high-grade partial-thickness and small full-thickness rotator cuff tears and factors affecting rotator cuff healing. Cohort study; Level of evidence, 3. Included in the study were 55 consecutive patients (mean age, 57.9 ± 7.2 years) who underwent arthroscopic repair for high-grade partial-thickness (n = 34) and small full-thickness (n = 21) rotator cuff tears. The study patients also underwent magnetic resonance imaging (MRI) preoperatively and computed tomography arthrography (CTA) at least 6 months postoperatively, and their functional outcomes were evaluated preoperatively and at the last follow-up (>24 months). All partial-thickness tears were repaired after being converted to full-thickness tears; thus, the repair process was almost the same as for small full-thickness tears. The tendinosis of the torn tendon was graded from the MRI images using a 4-point scale, and the reliabilities were assessed. The outcomes between high-grade partial-thickness tears that were converted to small full-thickness tears and initially small full-thickness tears were compared, and factors affecting outcomes were evaluated. The inter- and intraobserver reliabilities of the tendinosis grade were good (intraclass correlation coefficient, 0.706 and 0.777, respectively). Failure to heal as determined by CTA was observed in 12 patients with a high-grade partial-thickness tear (35.3%; complete failure in 4 and partial failure in 8) and in 3 patients with a small full-thickness tear (14.3%; complete failure in 1 and partial failure in 2). The patients with high-grade partial-thickness rotator cuff tears showed a higher tendinosis grade than did those with small full-thickness tears (P = .014), and the severity of the tendinosis was related to the failure to heal (P = .037). Tears with a higher tendinosis grade showed a 7.64-times higher failure rate (95% CI, 1.43-36.04) than did those with a lower tendinosis grade (P = .013). All functional outcome scores improved after surgery (all P < .001); however, there was no difference between groups. The high-grade partial-thickness rotator cuff tears showed more severe tendinosis compared with the small full-thickness tears in this study. Contrary to previous impressions that tear size or fatty infiltration is the factor that most influences healing, tendinosis severity assessed by preoperative MRI was the only factor associated with failure to heal, given the numbers available for analysis, in patients with partial-thickness and small full-thickness rotator cuff tears. Surgeons should pay more attention to tendon quality during repair surgery or rehabilitation in smaller rotator cuff tears, especially in high-grade partial-thickness tears with severe tendinosis. © 2014 The Author(s).

  6. [The clinical effect of anti-rotation reduction internal fixator on the treatment of fresh thoracolumbar spine fracture].

    PubMed

    Pan, Xianming; Quan, Yi; Tan, Yingjun; Zhang, Bo; Wang, Yuanshan; Huang, Tong; Ma, Zehui; Liao, Dongfa; Li, Ting; Liu, Jinbiao

    2005-03-15

    To evaluate the effect of self-designed anti-rotation reduction internal fixator (ARRIF) on treating different spine segment fracture. From August 1999 to March 2003, 76 patients(48 males and 28 females, aged from 22 to 59 with an average of 34.1) with thoracolumbar fracture were operatively treated by ARRIF. The follow-up period ranged from 6 to 21 months (15 months in average). Classification according to injury segment: flexion compression fracture 27 cases, burst fracture 42 cases, flexion distraction injury 3 cases, flexion revolving type fracture dislocation 2 cases, shear force type dislocation 2 cases. Classification according Frankel's grade: A grade 16 cases, B grade 15 cases, C grade 27 cases, D grade 10 cases, E grade 8 cases. Operation duration, volume of bleeding, incidence post-operation complication and effect of reduction-fixation were observed. The operation duration of ARRIF was 1.2 h in average, and there was about 200 ml volume of bleeding during operation. The nerve function showed one Frankel's grade improvement after operation were as follows: A grade 8 cases (50%), B grade 11 cases (73.3%), C grade 20 cases (74.1%), D grade 3 cases (30%); 2 Frankel's E cases have no nerve function changes. The nerve function damage have no aggravation in all the patients, the postoperation Cobb's angle was averagely corrected 22 degrees. The horizontal displacement of dislocation vertebrae was averagely corrected 28% in sagittal plane, the statistical analysis had significant variance (P < 0.01). ARRIF had no complications of the breakage of screws and rods. ARRIF proves to be a valid internal fixator in reducing and fixing different thoracic lumbar segment spine fracture.

  7. Functional evaluation of patient after arthroscopic repair of rotator cuff tear.

    PubMed

    Kumar, Rohit; Jadhav, Umesh

    2014-06-01

    Rotator cuff tear is a common problem either after trauma or after degenerative tear in old age group. Arthroscopic repair is the current concept of rotator cuff repair. Here, we are trying to evaluate the functional outcome after arthroscopic repair of full thickness rotator cuff tear (single row) in Indian population. Twenty five patients (14 males and 11 females) who underwent arthroscopic repair of full thickness rotator cuff tear at a single institution were included in the study. Postoperatively patient's shoulder was rated according to UCLA score, pain was graded according to the visual analog score. The range of motion was analysed and documented. The mean age of the patients were 50.48 years. The preoperative VAS score mode was 7 and post operative VAS was 1 (p value <0.001). The UCLA grading was good in 80% (n = 20), fair in 12% (n = 3), excellent in 8% (n = 2) and poor results were seen in none of the patients. The mean UCLA improved from a score of 15.84 to 30.28 with a p value <0.001. Mean postoperative forward flexion was 161.6°, mean abduction was 147.6° and mean external rotation was 45.4°. Arthroscopic repair is a good procedure for full thickness rotator cuff tear with minimal complications. The newer double row repair claims to be biomechanically superior with faster healing rates without functional advantages, hence we used a single row repair considering the Indian population and the cost effectiveness of the surgery with good to excellent results.

  8. The incidence and effect of fatty atrophy, positive tangent sign, and rotator cuff tears on outcomes after total shoulder arthroplasty.

    PubMed

    Choate, W Stephen; Shanley, Ellen; Washburn, Richard; Tolan, Stefan J; Salim, Tariq I; Tadlock, Josh; Shealy, Elizabeth C; Long, Catherine D; Crawford, Ashley E; Kissenberth, Michael J; Lonergan, Keith T; Hawkins, Richard J; Tokish, John M

    2017-12-01

    Treatment choices for total shoulder arthroplasty (TSA) in the absence of full-thickness rotator cuff tears (RCTs) are not clearly defined in current literature. This study investigated the prevalence and effect of preoperative partial-thickness RCTs and muscular degenerative changes on postoperative outcomes after TSA. Medical records and magnetic resonance imaging studies were reviewed for patients who underwent TSA for primary glenohumeral osteoarthritis with minimum 2-year follow-up to determine preoperative tear classification, Goutallier grade, and supraspinatus tangent sign. Postoperative pain on the visual analog scale, range of motion, and patient outcomes scores were obtained to correlate preoperative RCT status, Goutallier grading, tangent sign, and postoperative outcomes. Patients with full-thickness RCT on preoperative magnetic resonance imaging were excluded. Forty-five patients met all inclusion criteria (average age, 65 ± 10 years; average follow-up, 43 months). Of the patients undergoing TSA, 40% had a significant (>50% thickness) partial RCT. Grade 3 to 4 Goutallier changes were noted in 22% of all patients, and 13% demonstrated grade 3 to 4 changes in the context of no tear. Positive tangent sign was present in 7% of all patients. The preoperative Goutallier grade of the infraspinatus was significantly negatively correlated with postoperative forward elevation (P = .02) and external rotation (P = .05), but rotator cuff pathology, including tear status, Goutallier grade, and the presence of a tangent sign, did not correlate with postoperative functional outcome scores. Even in the absence of a full-thickness RCT, rotator cuff atrophy, fatty infiltration, and partial thickness tearing are common findings. Although postoperative range of motion is correlated to Goutallier changes of the infraspinatus, rotator cuff pathology is not correlated to outcomes after TSA; therefore, one may proceed with TSA without concern of their effect on postoperative outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Vibration analysis of a rotating functionally graded tapered microbeam based on the modified couple stress theory by DQEM

    NASA Astrophysics Data System (ADS)

    Ghadiri, Majid; Shafiei, Navvab; Alireza Mousavi, S.

    2016-09-01

    Due to having difficulty in solving governing nonlinear differential equations of a non-uniform microbeam, a few numbers of authors have studied such fields. In the present study, for the first time, the size-dependent vibration behavior of a rotating functionally graded (FG) tapered microbeam based on the modified couple stress theory is investigated using differential quadrature element method (DQEM). It is assumed that physical and mechanical properties of the FG microbeam are varying along the thickness that will be defined as a power law equation. The governing equations are determined using Hamilton's principle, and DQEM is presented to obtain the results for cantilever and propped cantilever boundary conditions. The accuracy and validity of the results are shown in several numerical examples. In order to display the influence of size on the first two natural frequencies and consequently changing of some important microbeam parameters such as material length scale, rate of cross section, angular velocity and gradient index of the FG material, several diagrams and tables are represented. The results of this article can be used in designing and optimizing elastic and rotary-type micro-electro-mechanical systems like micro-motors and micro-robots including rotating parts.

  10. Rotator cuff muscle degeneration and tear severity related to myogenic, adipogenic, and atrophy genes in human muscle.

    PubMed

    Shah, Shivam A; Kormpakis, Ioannis; Cavinatto, Leonardo; Killian, Megan L; Thomopoulos, Stavros; Galatz, Leesa M

    2017-12-01

    Large rotator cuff tear size and advanced muscle degeneration can affect reparability of tears and compromise tendon healing. Clinicians often rely on direct measures of rotator cuff tear size and muscle degeneration from magnetic resonance imaging (MRI) to determine whether the rotator cuff tear is repairable. The objective of this study was to identify the relationship between gene expression changes in rotator cuff muscle degeneration to standard data available to clinicians. Radiographic assessment of preoperative rotator cuff tear severity was completed for 25 patients with varying magnitudes of rotator cuff tears. Tear width and retraction were measured using MRI, and Goutallier grade, tangent (tan) sign, and Thomazeau grade were determined. Expression of myogenic-, adipogenic-, atrophy-, and metabolism-related genes in biopsied muscles were correlated with tear width, tear retraction, Goutallier grade, tan sign, and Thomazeau grade. Tear width positively correlated with Goutallier grade in both the supraspinatus (r = 0.73) and infraspinatus (r = 0.77), along with tan sign (r = 0.71) and Thomazeau grade (r = 0.68). Decreased myogenesis (Myf5), increased adipogenesis (CEBPα, Lep, Wnt10b), and decreased metabolism (PPARα) correlated with radiographic assessments. Gene expression changes suggest that rotator cuff tears lead to a dramatic molecular response in an attempt to maintain normal muscle tissue, increase adipogenesis, and decrease metabolism. Fat accumulation and muscle atrophy appear to stem from endogenous changes rather than from changes mediated by infiltrating cells. Results suggest that chronic unloading of muscle, induced by rotator cuff tear, disrupts muscle homeostasis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2808-2814, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Nonlinear Buckling Analysis of Functionally Graded Graphene Reinforced Composite Shallow Arches with Elastic Rotational Constraints under Uniform Radial Load.

    PubMed

    Huang, Yonghui; Yang, Zhicheng; Liu, Airong; Fu, Jiyang

    2018-05-28

    The buckling behavior of functionally graded graphene platelet-reinforced composite (FG-GPLRC) shallow arches with elastic rotational constraints under uniform radial load is investigated in this paper. The nonlinear equilibrium equation of the FG-GPLRC shallow arch with elastic rotational constraints under uniform radial load is established using the Halpin-Tsai micromechanics model and the principle of virtual work, from which the critical buckling load of FG-GPLRC shallow arches with elastic rotational constraints can be obtained. This paper gives special attention to the effect of the GPL distribution pattern, weight fraction, geometric parameters, and the constraint stiffness on the buckling load. The numerical results show that all of the FG-GPLRC shallow arches with elastic rotational constraints have a higher buckling load-carrying capacity compared to the pure epoxy arch, and arches of the distribution pattern X have the highest buckling load among four distribution patterns. When the GPL weight fraction is constant, the thinner and larger GPL can provide the better reinforcing effect to the FG-GPLRC shallow arch. However, when the value of the aspect ratio is greater than 4, the flakiness ratio is greater than 103, and the effect of GPL's dimensions on the buckling load of the FG-GPLRC shallow arch is less significant. In addition, the buckling model of FG-GPLRC shallow arch with elastic rotational constraints is changed as the GPL distribution patterns or the constraint stiffness changes. It is expected that the method and the results that are presented in this paper will be useful as a reference for the stability design of this type of arch in the future.

  12. Shoulder abduction and external rotation restoration with nerve transfer.

    PubMed

    Kostas-Agnantis, Ioannis; Korompilias, Anastasios; Vekris, Marios; Lykissas, Marios; Gkiatas, Ioannis; Mitsionis, Gregory; Beris, Alexander

    2013-03-01

    In upper brachial plexus palsy patients, loss of shoulder function and elbow flexion is obvious as the result of paralysed muscles innervated by the suprascapular, axillary and musculocutaneus nerve. Shoulder stabilisation, restoration of abduction and external rotation are important as more distal functions will be affected by the shoulder situation. Between 2005 and 2011, eleven patients with upper type brachial plexus palsy were operated on with triceps nerve branch transfer to anterior axillary nerve branch and spinal accessory nerve transfer to the suprascapular nerve for shoulder abduction and external rotation restoration. Nine patients met the inclusion criteria for the study. All patients were men with ages ranged from 21 to 35 years (average, 27.4 years). The interval between injury and surgery ranged from 4 to 11 months (average, 7.2 months). Atrophy of the supraspinatus, infraspinatus and deltoid muscle and subluxation at the glenohumeral joint was obvious in all patients preoperatively. During the pre-op examination all patients had at least muscle grading 4 on the triceps muscle. The mean post-operative value of shoulder abduction was 112.2° (range: 60-170°) while preoperatively none of the patients was able for abduction (p<0.001). The mean post-operative value of shoulder external rotation was 66° (range: 35-110°) while preoperatively none of them was able for external rotation (p<0.001). Postoperative values of shoulder abduction were significantly better that those of external rotation (p=0.0004). The postoperative average muscle grading for shoulder abduction according the MRC scale was 3.6±0.5 and for the shoulder external rotation was 3.2±0.4. Combined nerve transfer by using the spinal accessory nerve for suprascapular nerve neurotisation and one of the triceps nerve branches for axillary nerve and teres minor branch neurotisation is an excellent choice for shoulder abduction and external rotation restoration. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. [Kinematics of the healthy and arthritic hip joint during walking. A study of 136 subjects].

    PubMed

    Dujardin, F; Aucouturier, T; Bocquet, G; Duparc, F; Weber, J; Thomine, J M

    1998-11-01

    The study aimed to analyze the spatiotemporal parameters and 3-dimensional pelvic and hip kinematic components during gait in two groups: patients with a primitive osteoarthritis of the hip and control normal subjects. The study included 51 patients, ranged from 42 to 81 years, and 86 normal subjects. Gait analysis was performed using the optoelectronic system VICON with 5 cameras in free-speed conditions. Functional grading of the patients was assessed by Lequesne's score. Thickness of the hip cartilage was measured on pelvis AP radiograph. A preliminary study was performed to measure reliability of the data on 11 patients. At the initial stage of osteoarthritis, speed, cadence, stride length and hip flexion-extension motion appeared as very close to normal data. After this initial stage, there was a statistical relationship between these parameters and arthritis functional grading. Pelvis rotation around the vertical axis did not change according to severity of functional grading. The mean value of this component of pelvis motion was 10 degrees in the pathological group, whereas it was 8 degrees in the female normal group, and 7 degrees in the male group. There were no significant relationship between radiographical thickness of hip cartilage and functional grading of patients or gait parameters. This study demonstrates that spatiotemporal gait parameters and kinematic data appear as quantitative index which could be used in future studies. It also shows that pelvic rotation is greater in pathological group than in normal subjects, even in the extreme beginning of the hip osteoarthritis. This particularity can be explained as a very early consequence of the arthritis or, in the opposite, as risk factor.

  14. Significant consequences of heat generation/absorption and homogeneous-heterogeneous reactions in second grade fluid due to rotating disk

    NASA Astrophysics Data System (ADS)

    Hayat, Tasawar; Qayyum, Sumaira; Alsaedi, Ahmed; Ahmad, Bashir

    2018-03-01

    Flow of second grade fluid by a rotating disk with heat and mass transfer is discussed. Additional effects of heat generation/absorption are also analyzed. Flow is also subjected to homogeneous-heterogeneous reactions. The convergence of computed solution is assured through appropriate choices of initial guesses and auxiliary parameters. Investigation is made for the effects of involved parameters on velocities (radial, axial, tangential), temperature and concentration. Skin friction and Nusselt number are also analyzed. Graphical results depict that an increase in viscoelastic parameter enhances the axial, radial and tangential velocities. Opposite behavior of temperature is observed for larger values of viscoelastic and heat generation/absorption parameters. Concentration profile is increasing function of Schmidt number, viscoelastic parameter and heterogeneous reaction parameter. Magnitude of skin friction and Nusselt number are enhanced for larger viscoelastic parameter.

  15. A study of safety and tolerability of rotatory vestibular input for preschool children

    PubMed Central

    Su, Wen-Ching; Lin, Chin-Kai; Chang, Shih-Chung

    2015-01-01

    The objectives of this study were to determine a safe rotatory vestibular stimulation input for preschool children and to study the effects of grade level and sex of preschool children during active, passive, clockwise, and counterclockwise rotation vestibular input. This study adopted purposive sampling with 120 children from three kindergarten levels (K1, K2, and K3) in Taiwan. The subjects ranged in age from 46 to 79 months of age (mean: 62.1 months; standard deviation =9.60). This study included testing with four types of vestibular rotations. The number, duration, and speed of rotations were recorded. The study found that the mean number of active rotations was 10.28; the mean duration of rotation was 24.17 seconds; and the mean speed was 2.29 seconds per rotation. The mean number of passive rotations was 23.04. The differences in number of rotations in clockwise, counterclockwise, active, and passive rotations were not statistically significant. Sex and grade level were not important related factors in the speed and time of active rotation. Different sexes, rotation methods (active, passive), and grades made significant differences in the number of rotations. The safety and tolerability of rotatory vestibular stimulation input data obtained in this study can provide useful reference data for therapists using sensory integration therapy. PMID:25657579

  16. An ultrasound evaluation of laryngeal mask airway position in pediatric patients: an observational study.

    PubMed

    Kim, Jeongmin; Kim, Ji Young; Kim, Won Oak; Kil, Hae Keum

    2015-02-01

    In children, the laryngeal mask airway (LMA) is frequently displaced within the hypopharynx, resulting in repositioning of the device. When the tip of the LMA is placed in the esophageal inlet, the arytenoids are moved ventrally. When the LMA is rotated or deviated, the ventral movement of the arytenoids may result in asymmetric elevation of an arytenoid cartilage, which can be detected with ultrasound (US). In this study, we sought to estimate the incidence of LMA malposition detected with US in pediatric patients. The primary end point was to compare the incidence of LMA malposition between US and fiber optic bronchoscopy (FOB). The secondary end points were to find the interrelationship between US-detected and FOB-detected malposition of the LMA and to locate the diagnostic performance of US in detecting LMA malposition. In this observational study, 100 consecutive children were included. After anesthetic induction, US evaluation was performed before and after LMA insertion to obtain the glottic image on the anterior neck. FOB was performed to assess LMA position (FOB LMA grade and LMA rotation grade). With a post-LMA US image, the symmetry of the arytenoid cartilages was evaluated. Asymmetrical elevation of an arytenoid cartilage in reference to the glottic midline and the opposite arytenoid cartilage was graded as 0 to 3 (US arytenoid grade). The interrelationships between US arytenoid grade and FOB LMA grade or LMA rotation grade were assessed. The incidence of asymmetrical elevation of an arytenoid was 50% (95% confidence interval [CI], 40%-60%). On FOB, the incidence of LMA malposition was 78% (95% CI, 69%-86%), and that of LMA rotation was 43% (95% CI, 33%-53%). The incidence of LMA malposition was higher with FOB (P < 0.0001), but the incidence of rotation was similar (P = 0.395). US arytenoid grade did not correlate with FOB LMA grade (P = 0.611) but showed a significant correlation with LMA rotation grade (P < 0.0001; 95% CI, 60%-83%). To detect a rotated LMA, US had a sensitivity of 93% (95% CI, 81%-98%) and a specificity of 82% (95% CI, 70%-91%). The positive and negative predictive values were 80% (95% CI, 66%-90%) and 94% (95% CI, 83%-99%), respectively. The accuracy was 87% (95% CI, 79%-93%). Although US could not detect the suboptimal depth of an LMA, US has promise of being an accurate tool in detecting a rotated LMA.

  17. The Grades That Clinical Teachers Give Students Modifies the Grades They Receive

    ERIC Educational Resources Information Center

    Paget, Michael; Brar, Gurbir; Veale, Pamela; Busche, Kevin; Coderre, Sylvain; Woloschuk, Wayne; McLaughlin, Kevin

    2018-01-01

    Prior studies have shown a correlation between the grades students receive and how they rate their teacher in the classroom. In this study, the authors probe this association on clinical rotations and explore potential mechanisms. All In-Training Evaluation Reports (ITERs) for students on mandatory clerkship rotations from April 1, 2013 to January…

  18. Time-dependent changes after latissimus dorsi transfer: tenodesis or tendon transfer?

    PubMed

    Erşen, Ali; Ozben, Hakan; Demirhan, Mehmet; Atalar, Ata Can; Kapıcıoğlu, Mehmet

    2014-12-01

    Transfer of the latissimus dorsi tendon to the posterosuperior part of the rotator cuff is an option in active patients with massive rotator cuff tears to restore shoulder elevation and external rotation. However, it is unknown whether this treatment prevents progression of cuff tear arthropathy. The purpose of this study was to determine whether the observed improvement in shoulder function in the early postoperative period with latissimus dorsi tendon transfer for irreparable rotator cuff tears will be permanent or will deteriorate in the midterm period (at 1-5 years after surgery). During a 6-year period, we performed 11 latissimus dorsi tendon transfers in 11 patients for patients with massive, irreparable, chronic tears of the posterosuperior part of the rotator cuff (defined as > 5 cm supraspinatus and infraspinatus tendon tears with Goutallier Grade 3 to 4 fatty infiltration on MRI), for patients who were younger than 65 years of age, and had high functional demands and intact subscapularis function. No patients were lost to followup; minimum followup was 12 months (median, 33 months; range, 12-62 months). The mean patient age was 55 years (median, 53 years; range, 47-65 years). Shoulder forward elevation, external rotation, and Constant-Murley and American Shoulder and Elbow Surgeons scores were assessed. Pain was assessed by a 0- to 10-point visual analog scale. Acromiohumeral distance and cuff tear arthropathy (staged according to the Hamada classification) were evaluated on radiographs. Shoulder forward elevation, external rotation, Constant-Murley scores, and American Shoulder and Elbow Surgeons scores improved at 6 months. However, although shoulder motion values and Constant-Murley scores remained unchanged between the 6-month and latest evaluations, American Shoulder and Elbow Surgeons scores decreased in this period (median, 71; range, 33-88 versus median, 68; range, 33-85; p = 0.009). Visual analog scale scores improved between the preoperative and 6-month evaluations but then worsened (representing worse pain) between the 6-month and latest evaluations (median, 2; range, 0-5 versus median, 2; range, 1-6; p = 0.034), but scores at latest followup were still lower than preoperative values (median, 7; range, 4-8; p = 0.003). Although acromiohumeral distance values were increased at 6 months (median, 8 mm; range, 6-10 mm; p = 0.023), the values at latest followup (median, 8 mm; range, 5-10 mm) were no different from the preoperative ones (mean, 7 mm; range, 6-9 mm; p > 0.05). According to Hamada classification, all patients were Grade 1 both pre- and postoperatively, except one who was Grade 3 at latest followup. The latissimus dorsi tendon transfer may improve shoulder function in irreparable massive rotator cuff tears. However, because the tenodesis effect loses its strength with time, progression of the arthropathy should be expected over time. Nevertheless, latissimus dorsi tendon transfer may help to delay the need for reverse shoulder arthroplasty for these patients. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.

  19. Functional Outcomes and Predictors of Failure After Rotator Cuff Repair During Total Shoulder Arthroplasty.

    PubMed

    Livesey, Michael; Horneff, John G; Sholder, Daniel; Lazarus, Mark; Williams, Gerald; Namdari, Surena

    2018-05-01

    A well-functioning rotator cuff is necessary for successful anatomic total shoulder arthroplasty (TSA). This study evaluated patients who underwent concomitant TSA and rotator cuff repair (RCR) for functional outcomes, revision rates, and predictors of poor results. Retrospective chart review was conducted to identify patients who underwent TSA and RCR. Demographic data, rotator cuff tear and RCR characteristics, range of motion, and radiographs were recorded. Minimum 2-year functional outcomes were obtained. Predictors of reoperation and/or poor clinical results were determined. Forty-five patients met inclusion criteria (22 high-grade partial-thickness and 23 full-thickness tears). Fourteen (31%) patients were labeled as having a poor result; 8 (18%) patients required reoperation. There was a significant difference between the acromiohumeral interval preoperatively and immediately postoperatively (P=.013). However, at maximum radiographic follow-up, the acromiohumeral interval was not significantly different from preoperative values (P=.86). Patients with a preoperative acromiohumeral interval of less than 8 mm had an increased rate of cuff-related reoperation (P=.003). Although concomitant TSA and RCR is a reasonable consideration, 31% of patients had a poor clinical result. An acromiohumeral interval of less than 8 mm was a predictor of cuff-related reoperation and may be an indication to consider reverse arthroplasty in the setting of joint arthrosis with a rotator cuff tear. [Orthopedics. 2018; 41(3):e334-e339.]. Copyright 2018, SLACK Incorporated.

  20. Grade Inflation in Medical Student Radiation Oncology Clerkships: Missed Opportunities for Feedback?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grover, Surbhi, E-mail: surbhi.grover@uphs.upenn.edu; Swisher-McClure, Samuel; Sosnowicz, Stasha

    Purpose: To test the hypothesis that medical student radiation oncology elective rotation grades are inflated and cannot be used to distinguish residency applicants. Methods and Materials: The records of 196 applicants to a single radiation oncology residency program in 2011 and 2012 were retrospectively reviewed. The grades for each rotation in radiation oncology were collected and converted to a standardized 4-point grading scale (honors, high pass, pass, fail). Pass/fail grades were scored as not applicable. The primary study endpoint was to compare the distribution of applicants' grades in radiation oncology with their grades in medicine, surgery, pediatrics, and obstetrics/gynecology core clerkships.more » Results: The mean United States Medical Licensing Examination Step 1 score of the applicants was 237 (range, 188-269), 43% had additional Masters or PhD degrees, and 74% had at least 1 publication. Twenty-nine applicants were graded for radiation oncology rotations on a pass/fail basis and were excluded from the final analysis. Of the remaining applicants (n=167), 80% received the highest possible grade for their radiation oncology rotations. Grades in radiation oncology were significantly higher than each of the other 4 clerkships studied (P<.001). Of all applicants, 195 of 196 matched into a radiation oncology residency. Higher grades in radiation oncology were associated with significantly higher grades in the pediatrics core clerkship (P=.002). However, other medical school performance metrics were not significantly associated with higher grades in radiation oncology. Conclusions: Although our study group consists of a selected group of radiation oncology applicants, their grades in radiation oncology clerkships were highly skewed toward the highest grades when compared with grades in other core clerkships. Student grading in radiation oncology clerkships should be re-evaluated to incorporate more objective and detailed performance metrics to allow for meaningful feedback to trainees and to better evaluate residency applicants to radiation oncology.« less

  1. Real-time sonoelastography in the diagnosis of rotator cuff tendinopathy.

    PubMed

    Lee, Sang-Uk; Joo, Sun Young; Kim, Sun Ki; Lee, Sang-Ho; Park, Sung-Ryeoll; Jeong, Changhoon

    2016-05-01

    Real-time sonoelastography can be used to assess tissue elasticity. The present study evaluated the relationship between tendon stiffness on sonoelastography and the magnetic resonance imaging (MRI) tendinosis grade in patients with rotator cuff tendinopathy. The study included 39 patients with chronic pain and no history of trauma or rotator cuff tear. The supraspinatus tendons were graded according to MRI findings (grade 0, normal; grade 1, mild tendinosis; grade 2, moderate tendinosis; grade 3, marked tendinosis), and the subcutaneous fat-to-tendon (Fat/T) and gel pad-to-tendon (Pad/T) strain ratios were assessed. We used the trend test to analyze the relationship of the MRI grade with the Fat/T strain ratio and the Pad/T strain ratio. Of the 39 patients, 9 had grade 0, 17 had grade 1, 12 had grade 2, and 1 had grade 3 tendinosis. The mean real-time elastography Fat/T and Pad/T strain ratios were 2.92 ± 2.13 and 20.77 ± 21.78 in patients with grade 0 tendinosis, 4.08 ± 4.09 and 21.78 ± 17.16 in patients with grade 1 tendinosis, 13.48 ± 10.19 and 83.00 ± 48.26 in patients with grade 2 tendinosis, and 12.3 ± 0.00 and 16.58 ± 0.00 in patients with grade 3 tendinosis, respectively. The Fat/T and Pad/T strain ratios were positively associated with the MRI grade (P <.001). The MRI tendinosis grade is associated with stiffness assessed using sonoelastography in patients with rotator cuff tendinopathy. Therefore, sonoelastography might be a useful diagnostic tool for supraspinatus tendinopathy. Level III; Diagnostic Study. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. Vibration analysis of rotating functionally graded Timoshenko microbeam based on modified couple stress theory under different temperature distributions

    NASA Astrophysics Data System (ADS)

    Ghadiri, Majid; Shafiei, Navvab

    2016-04-01

    In this study, thermal vibration of rotary functionally graded Timoshenko microbeam has been analyzed based on modified couple stress theory considering temperature change in four types of temperature distribution on thermal environment. Material properties of FG microbeam are supposed to be temperature dependent and vary continuously along the thickness according to the power-law form. The axial forces are also included in the model as the thermal and true spatial variation due to the rotation. Governing equations and boundary conditions have been derived by employing Hamiltonian's principle. The differential quadrature method is employed to solve the governing equations for cantilever and propped cantilever boundary conditions. Validations are done by comparing available literatures and obtained results which indicate accuracy of applied method. Results represent effects of temperature changes, different boundary conditions, nondimensional angular velocity, length scale parameter, different boundary conditions, FG index and beam thickness on fundamental, second and third nondimensional frequencies. Results determine critical values of temperature changes and other essential parameters which can be applicable to design micromachines like micromotor and microturbine.

  3. Single-stage Reconstruction of Elbow Flexion Associated with Massive Soft-Tissue Defect Using the Latissimus Dorsi Muscle Bipolar Rotational Transfer

    PubMed Central

    Cuéllar, Vanessa G.; Ghiassi, Alidad; Sharpe, Frances

    2016-01-01

    Introduction: In the upper extremity, the latissimus dorsi muscle can be used as an ipsilateral rotational muscle flap for soft-tissue coverage or functional reconstruction of arm and elbow. Patients who have both major soft-tissue loss and functional deficits can be successfully treated with a single-stage functional latissimus dorsi rotational muscle transfer that provides simultaneous soft-tissue coverage and functional reconstruction. Methods: Our data base was queried for all patients undergoing a rotational latissimus dorsi muscle transfer for simultaneous soft-tissue coverage and functional reconstruction of elbow flexion. Four patients were identified. A chart review documented the mechanism of injury, associated injuries, soft-tissue defect size, number of surgical procedures, length of follow-up, last elbow range of motion, and flexion strength. Results: Four patients with loss of elbow flexion due to traumatic loss of the anterior compartment muscles and the overlying soft tissue underwent simultaneous soft-tissue coverage and elbow flexorplasty using the ipsilateral latissimus dorsi as a bipolar muscle rotational tissue transfer. All flaps survived and had a recovery of Medical Research Council Grade 4/5 elbow flexion strength. No additional procedures were required for elbow flexion. The surgical technique is described and supplemented with surgical technique video and patient outcome. Conclusions: This patient series augments the data provided in other series supporting the safety and efficacy of this procedure which provides both soft-tissue coverage and functional restoration of elbow flexion as a single-stage procedure in the setting of massive traumatic soft-tissue loss of the arm. PMID:27757363

  4. Single-stage Reconstruction of Elbow Flexion Associated with Massive Soft-Tissue Defect Using the Latissimus Dorsi Muscle Bipolar Rotational Transfer.

    PubMed

    Stevanovic, Milan V; Cuéllar, Vanessa G; Ghiassi, Alidad; Sharpe, Frances

    2016-09-01

    In the upper extremity, the latissimus dorsi muscle can be used as an ipsilateral rotational muscle flap for soft-tissue coverage or functional reconstruction of arm and elbow. Patients who have both major soft-tissue loss and functional deficits can be successfully treated with a single-stage functional latissimus dorsi rotational muscle transfer that provides simultaneous soft-tissue coverage and functional reconstruction. Our data base was queried for all patients undergoing a rotational latissimus dorsi muscle transfer for simultaneous soft-tissue coverage and functional reconstruction of elbow flexion. Four patients were identified. A chart review documented the mechanism of injury, associated injuries, soft-tissue defect size, number of surgical procedures, length of follow-up, last elbow range of motion, and flexion strength. Four patients with loss of elbow flexion due to traumatic loss of the anterior compartment muscles and the overlying soft tissue underwent simultaneous soft-tissue coverage and elbow flexorplasty using the ipsilateral latissimus dorsi as a bipolar muscle rotational tissue transfer. All flaps survived and had a recovery of Medical Research Council Grade 4/5 elbow flexion strength. No additional procedures were required for elbow flexion. The surgical technique is described and supplemented with surgical technique video and patient outcome. This patient series augments the data provided in other series supporting the safety and efficacy of this procedure which provides both soft-tissue coverage and functional restoration of elbow flexion as a single-stage procedure in the setting of massive traumatic soft-tissue loss of the arm.

  5. Grading apical vertebral rotation without a computed tomography scan: a clinically relevant system based on the radiographic appearance of bilateral pedicle screws.

    PubMed

    Upasani, Vidyadhar V; Chambers, Reid C; Dalal, Ali H; Shah, Suken A; Lehman, Ronald A; Newton, Peter O

    2009-08-01

    Bench-top and retrospective analysis to assess vertebral rotation based on the appearance of bilateral pedicle screws in patients with adolescent idiopathic scoliosis (AIS). To develop a clinically relevant radiographic grading system for evaluating postoperative thoracic apical vertebral rotation that would correlate with computed tomography (CT) measures of rotation. The 3-column vertebral body control provided by bilateral pedicle screws has enabled scoliosis surgeons to develop advanced techniques of direct vertebral derotation. Our ability to accurately quantify spinal deformity in the axial plane, however, continues to be limited. Trigonometry was used to define the relationship between the position of bilateral pedicle screws and vertebral rotation. This relationship was validated using digital photographs of a bench-top model. The mathematical relationships were then used to calculate vertebral rotation from standing postoperative, posteroanterior radiographs in AIS patients and correlated with postoperative CT measures of rotation. Fourteen digital photographs of the bench-top model were independently analyzed twice by 3 coauthors. The mathematically calculated degree of rotation was found to correlate significantly with the actual degree of rotation (r = 0.99; P < 0.001) and the intra- and interobserver reliability for these measurements were both excellent (kappa = 0.98 and kappa = 0.97, respectively). In the retrospective analysis of 17 AIS patients, the average absolute difference between the radiographic measurement of rotation and the CT measure was only 1.9 degrees +/- 2.0 degrees (r = 0.92; P < 0.001). Based on these correlations a simple radiographic grading system for postoperative apical vertebral rotation was developed. An accurate assessment of vertebral rotation can be performed radiographically, using screw lengths and screw tip-to-rod distances of bilateral segmental pedicle screws and a trigonometric calculation. These data support the use of a simple radiographic grading system to approximate apical vertebral rotation in AIS patients treated with bilateral apical pedicle screws.

  6. Student Interests and Attitude Change toward Drug Educators as a Function of Sex and Role Interaction.

    ERIC Educational Resources Information Center

    Cotten-Huston, Annie L.

    1982-01-01

    Focused on recorded tapes and sex-role interaction of 12 sessions on drug abuse. Subjects were 247 seventh-grade males and females. Communicators (males and females) made two presentations with roles rotated according to ex-addict/learned specialist. Results indicated female and male students were influenced most by female specialist…

  7. Posterolateral Corner Reconstruction using the Anatomical Two-Tailed Graft Technique: Clinical Outcomes in the Multiligament Injured Knee.

    PubMed

    Woodmass, Jarret M; Sanders, Thomas L; Johnson, Nick R; Wu, Isabella T; Krych, Aaron J; Stuart, Michael J; Levy, Bruce A

    2018-02-14

    Injury to the posterolateral corner (PLC) of the knee can lead to both varus and rotational instability. Multiple PLC reconstruction techniques have been described, including one-tailed graft (fibula-based constructs) or two-tailed graft (combined fibula- and tibia-based constructs). The purpose of our study was to evaluate the clinical outcomes of anatomical two-tailed graft reconstruction of the PLC in the setting of multiligament knee injuries (MKLIs) with grade III varus instability. Patients were identified through a prospective MLKI database between 2004 and 2013. Patients who received fibular collateral ligament and PLC reconstructions using a two-tailed graft and had a minimum follow-up of 2 years were included. Patients were assessed for clinical laxity grade, range of motion, and functional outcomes using Lysholm and International Knee Documentation Committee (IKDC) scores. Twenty patients (16 male, 4 female) with a mean age of 30.7 (range: 16-52) and a mean follow-up of 52.2 months (range: 24-93 months) were included. Knee dislocation (KD) grades included: 4 KD-1, 10 KD 3-L, 5 KD-4, and 1 KD-5. No patients had isolated PLC injuries. Mean IKDC and Lysholm score were 73.1 ± 25.8 and 78 ± 26, respectively. Mean range of motion was -1.1 to 122.8. In full extension, two patients (10%) had grade 1 laxity to varus stress. In 30 degrees of knee flexion, five (25%) patients had grade 1 laxity, and two (10%) had grade 2 laxity. Anatomical two-tailed PLC reconstruction can reliably restore varus stability when performed on patients with MLKIs and type C posterolateral instability with hyperextension external rotation recurvatum deformity. Satisfactory functional outcome scores were achieved in the majority of patients. This study supports the use of an anatomical two-tailed PLC reconstruction in the multiligament injured knee. The level of evidence is IV, case series. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. Prognostic Factors Affecting Rotator Cuff Healing After Arthroscopic Repair in Small to Medium-sized Tears.

    PubMed

    Park, Ji Soon; Park, Hyung Jun; Kim, Sae Hoon; Oh, Joo Han

    2015-10-01

    Small and medium-sized rotator cuff tears usually have good clinical and anatomic outcomes. However, healing failure still occurs in some cases. To evaluate prognostic factors for rotator cuff healing in patients with only small to medium-sized rotator cuff tears. Case-control study; Level of evidence, 3. Data were prospectively collected from 339 patients with small to medium-sized rotator cuff tears who underwent arthroscopic repair by a single surgeon between March 2004 and August 2012 and who underwent magnetic resonance imaging or computed tomographic arthrography at least 1 year after surgery. The mean age of the patients was 59.8 years (range, 39-80 years), and the mean follow-up time was 20.8 months (range, 12-66 months). The functional evaluation included the visual analog scale (VAS) for pain, American Shoulder and Elbow Surgeons score, Constant-Murley score, and Simple Shoulder Test. Postoperative VAS for pain and functional scores improved significantly compared with preoperative values (P < .001). Forty-five healing failures occurred (13.3%), and fatty degeneration of the infraspinatus muscle, tear size (anteroposterior dimension), and age were significant factors affecting rotator cuff healing (P < .001, = .018, and = .011, respectively) in multivariate logistic regression analysis. Grade II and higher infraspinatus fatty degeneration correlated with a higher failure rate. The failure rate was also significantly higher in patients with a tear >2 cm in size (34.2%) compared with patients with a tear ≤2 cm (10.6%) (P < .001). A receiver operating characteristic curve was used to determine the predictive cut-off value for the oldest age and the largest tear size for successful healing, which were calculated as 69 years and 2 cm, respectively, with a specificity of 90%. In small to medium-sized rotator cuff tears, grade II fatty degeneration of the infraspinatus muscle according to the Goutallier classification could be a reference point for successful healing, and anatomic outcomes might be better if repair is performed before the patient is 69 years old and the tear size exceeds 2 cm. © 2015 The Author(s).

  9. Are pain location and physical examinations useful in locating a tear site of the rotator cuff?

    PubMed

    Itoi, Eiji; Minagawa, Hiroshi; Yamamoto, Nobuyuki; Seki, Nobutoshi; Abe, Hidekazu

    2006-02-01

    Pain is the most common symptom of patients with rotator cuff tendinopathy, but little is known about the relationship between the site of pain and the site of cuff pathologic lesions. Also, accuracies of physical examinations used to locate a tear by assessing the muscle strength seem to be affected by the threshold for muscle weakness, but no studies have been reported regarding the efficacies of physical examinations in reference to their threshold. Pain location is useful in locating a tear site. Efficacies of physical examinations to evaluate the function of the cuff muscles depend on the threshold for muscle weakness. Case series; Level of evidence, 4. The authors retrospectively reviewed the clinical charts of 160 shoulders of 149 patients (mean age, 53 years) with either rotator cuff tears (140 shoulders) or cuff tendinitis (20 shoulders). The location of pain was recorded on a standardized form with 6 different areas. The diagnostic accuracies of the following tests were assessed with various thresholds for muscle weakness: supraspinatus test, the external rotation strength test, and the lift-off test. Lateral and anterior portions of the shoulder were the most common sites of pain regardless of existence of tear or tear location. The supraspinatus test was most accurate when it was assessed to have positive results with the muscle strength less than manual muscle testing grade 5, whereas the lift-off test was most accurate with a threshold less than grade 3. The external rotation strength test was most accurate with a threshold of less than grade 4+. The authors conclude that pain location is not useful in locating the site of a tear, whereas the physical examinations aiming to locate the tear site are clinically useful when assessed to have positive results with appropriate threshold for muscle weakness.

  10. Changes in Lower Limb Strength and Function Following Lumbar Spinal Mobilization.

    PubMed

    Yuen, Tsoi Sze; Lam, Pui Yu; Lau, Mei Yan; Siu, Wai Lam; Yu, Ka Man; Lo, Chi Ngai; Ng, Joseph

    2017-10-01

    The purpose of this study was to investigate whether grade III passive lumbar rotational mobilization on L2-3 can improve hip flexor strength and performance in the single-leg triple-hop test in asymptomatic young adults. Twenty-four participants (12 men, 12 women) aged from 19 to 26 years who were positive in the hip flexor "break" test were recruited in this study. They were randomly allocated to the treatment group or sham group. Isometric hip flexor torque (N·m) and single-leg triple-hop distance (cm) were measured before and after a passive lumbar rotational mobilization or a sham intervention. After the intervention, both the treatment and sham groups exhibited a significant increase in longest hop distance (P = .040 and .044, respectively). The treatment group had a significantly higher (3.41 ± 5.44%) positive percentage change in torque than the sham group (-2.36 ± 5.81%) (P = .02). The study results indicated a potential effect of grade III passive lumbar rotational mobilization in improving hip flexor strength. However, whether the improvement in hopping performance was the result of a treatment effect or a learning effect could not be determined. Copyright © 2017. Published by Elsevier Inc.

  11. Speed of recovery after arthroscopic rotator cuff repair.

    PubMed

    Kurowicki, Jennifer; Berglund, Derek D; Momoh, Enesi; Disla, Shanell; Horn, Brandon; Giveans, M Russell; Levy, Jonathan C

    2017-07-01

    The purpose of this study was to delineate the time taken to achieve maximum improvement (plateau of recovery) and the degree of recovery observed at various time points (speed of recovery) for pain and function after arthroscopic rotator cuff repair. An institutional shoulder surgery registry query identified 627 patients who underwent arthroscopic rotator cuff repair between 2006 and 2015. Measured range of motion, patient satisfaction, and patient-reported outcome measures were analyzed for preoperative, 3-month, 6-month, 1-year, and 2-year intervals. Subgroup analysis was performed on the basis of tear size by retraction grade and number of anchors used. As an entire group, the plateau of maximum recovery for pain, function, and motion occurred at 1 year. Satisfaction with surgery was >96% at all time points. At 3 months, 74% of improvement in pain and 45% to 58% of functional improvement were realized. However, only 22% of elevation improvement was achieved (P < .001). At 6 months, 89% of improvement in pain, 81% to 88% of functional improvement, and 78% of elevation improvement were achieved (P < .001). Larger tears had a slower speed of recovery for Single Assessment Numeric Evaluation scores, forward elevation, and external rotation. Smaller tears had higher motion and functional scores across all time points. Tear size did not influence pain levels. The plateau of maximum recovery after rotator cuff repair occurred at 1 year with high satisfaction rates at all time points. At 3 months, approximately 75% of pain relief and 50% of functional recovery can be expected. Larger tears have a slower speed of recovery. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Quantitative assessment of fat infiltration in the rotator cuff muscles using water-fat MRI.

    PubMed

    Nardo, Lorenzo; Karampinos, Dimitrios C; Lansdown, Drew A; Carballido-Gamio, Julio; Lee, Sonia; Maroldi, Roberto; Ma, C Benjamin; Link, Thomas M; Krug, Roland

    2014-05-01

    To evaluate a chemical shift-based fat quantification technique in the rotator cuff muscles in comparison with the semiquantitative Goutallier fat infiltration classification (GC) and to assess their relationship with clinical parameters. The shoulders of 57 patients were imaged using a 3T MR scanner. The rotator cuff muscles were assessed for fat infiltration using GC by two radiologists and an orthopedic surgeon. Sequences included oblique-sagittal T1-, T2-, and proton density-weighted fast spin echo, and six-echo gradient echo. The iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) was used to measure fat fraction. Pain and range of motion of the shoulder were recorded. Fat fraction values were significantly correlated with GC grades (P < 0.0001, κ >0.9) showing consistent increase with GC grades (grade = 0, 0%-5.59%; grade = 1, 1.1%-9.70%; grade = 2, 6.44%-14.86%; grade = 3, 15.25%-17.77%; grade = 4, 19.85%-29.63%). A significant correlation between fat infiltration of the subscapularis muscle quantified with IDEAL versus 1) deficit in internal rotation (Spearman Rank Correlation Coefficient [SRC] = 0.39, 95% confidence interval [CI] 0.13-0.60, P < 0.01) and 2) pain (SRC coefficient = 0.313, 95% CI 0.049-0.536, P = 0.02) was found but was not seen between the clinical parameters and GC grades. Additionally, only quantitative fat infiltration measures of the supraspinatus muscle were significantly correlated with a deficit in abduction (SRC coefficient = 0.45, 95% CI 0.20-0.60, P < 0.01). An accurate and highly reproducible fat quantification in the rotator cuff muscles using water-fat magnetic resonance imaging (MRI) techniques is possible and significantly correlates with shoulder pain and range of motion. Copyright © 2013 Wiley Periodicals, Inc.

  13. Quantitative Assessment of Fat Infiltration in the Rotator Cuff Muscles using water-fat MRI

    PubMed Central

    Nardo, Lorenzo; Karampinos, Dimitrios C.; Lansdown, Drew A.; Carballido-Gamio, Julio; Lee, Sonia; Maroldi, Roberto; Ma, C. Benjamin; Link, Thomas M.; Krug, Roland

    2013-01-01

    Purpose To evaluate a chemical shift-based fat quantification technique in the rotator cuff muscles in comparison with the semi-quantitative Goutallier fat infiltration classification (GC) and to assess their relationship with clinical parameters. Materials and Methods The shoulders of 57 patients were imaged using a 3T MR scanner. The rotator cuff muscles were assessed for fat infiltration using GC by two radiologists and an orthopedic surgeon. Sequences included oblique-sagittal T1-, T2- and proton density-weighted fast spin echo, and six-echo gradient echo. The iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) was used to measure fat fraction. Pain and range of motion of the shoulder were recorded. Results Fat fraction values were significantly correlated with GC grades (p< 0.0001, kappa>0.9) showing consistent increase with GC grades (grade=0, 0%–5.59%; grade=1, 1.1%–9.70%; grade=2, 6.44%–14.86%; grade=3, 15.25%–17.77%; grade=4, 19.85%–29.63%). A significant correlation between fat infiltration of the subscapularis muscle quantified with IDEAL versus a) deficit in internal rotation (Spearman Rank Correlation Coefficient=0.39, 95% CI 0.13–0.60, p<0.01) and b) pain (Spearman Rank Correlation coefficient=0.313, 95% CI 0.049–0.536, p=0.02) was found but was not seen between the clinical parameters and GC grades. Additionally, only quantitative fat infiltration measures of the supraspinatus muscle were significantly correlated with a deficit in abduction (Spearman Rank Correlation Coefficient=0.45, 95% CI 0.20–0.60, p<0.01). Conclusion We concluded that an accurate and highly reproducible fat quantification in the rotator cuff muscles using water-fat MRI techniques is possible and significantly correlates with shoulder pain and range of motion. PMID:24115490

  14. Mobile-bearing knees reduce rotational asymmetric wear.

    PubMed

    Ho, Fang-Yuan; Ma, Hon-Ming; Liau, Jiann-Jong; Yeh, Chuan-Ren; Huang, Chun-Hsiung

    2007-09-01

    Polyethylene wear of bearing components is the most common long-term complication in total knee arthroplasty. One would anticipate differing kinematics would generate different wear patterns (including wear type, degree, and symmetry) on the articulating surface of mobile-bearing and fixed-bearing inserts. Because mobile-bearing designs facilitate movement of the insert relative to the tray when the knee rotates, we hypothesized mobile-bearing designs would reduce the incidence of rotational asymmetric wear. We examined 51 worn tibial inserts, including 15 from mobile-bearing rotating-platform posterior-cruciate-sacrificing dished prostheses and 36 from fixed-bearing posterior-cruciate-retaining flat prostheses, which were retrieved at revision surgery with an average implantation time of 115 months. We divided wear types into low-grade wear (burnishing, abrasion, and cold flow) and high-grade wear (scratching, pitting, metal embedding, and delamination) to assess wear degree of polyethylene. To assess symmetry of wear, the insert surface was divided into medial and lateral sides and each side was further divided into three equal zones along the anteroposterior direction. Low-grade wear was more common in mobile-bearing knees, whereas high-grade wear was more common in fixed-bearing knees. We identified no internal/external rotational asymmetric wear or anteroposterior asymmetric wear in mobile-bearing knees.

  15. The prospective evaluation of changes in fatty infiltration and shoulder strength in nonsurgically treated rotator cuff tears.

    PubMed

    Nakamura, Yoshihiro; Yokoya, Shin; Harada, Yohei; Shiraishi, Katsunori; Adachi, Nobuo; Ochi, Mitsuo

    2017-07-01

    The purpose of this study was to evaluate the relationship of fatty infiltration in rotator cuff muscles and shoulder strength in rotator cuff tears and these changes during nonsurgical treatment. Fifty-three shoulders from 47 patients (mean age: 69.9 years) diagnosed with rotator cuff tears by magnetic resonance imaging (MRI) were treated nonsurgically. The degrees of fatty infiltration in supraspinatus (SSP) and infraspinatus (ISP) muscles were graded by the modified Goutallier classification (grade 0-1, grade 2-3, or grade 4). The isometric strength of the abductors (Abd) and external rotators (ER) were examined with a hand dynamometer. We analyzed the correlation of the modified Goutallier classification in SSP and ISP muscles with the strength of Abd and ER at initial visit. In addition, MRI and strength tests were repeated after 24 ± 6 months, and changes in fatty infiltration and strength were examined. Fatty infiltration of SSP and ISP muscles had a negative correlation with the strengths of Abd and ER at initial visit, respectively. Six of 45 shoulders (SSP grade: 0-3) and 7 of 43 shoulders (ISP grade: 0-3) had progression of fatty infiltration. Predictive factor of a progression of fatty infiltration during follow-up was decreased initial strength of Abd. There was no significant change in the strength of Abd, and the strength of ER showed significant improvement between the initial and post-treatment measurements. Even in the subgroup that had progression of fatty infiltration at follow-up, the strength of Abd and ER did not decrease significantly. Although fatty infiltration of the rotator cuff muscles exhibited a negative correlation with muscle strength, fatty infiltration and muscle weakness did not progress at the same rate. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  16. Evaluation of a modified knee rotation angle in MRI scans with and without trochlear dysplasia: a parameter independent of knee size and trochlear morphology.

    PubMed

    Dornacher, Daniel; Trubrich, Angela; Guelke, Joachim; Reichel, Heiko; Kappe, Thomas

    2017-08-01

    Regarding TT-TG in knee realignment surgery, two aspects have to be considered: first, there might be flaws in using absolute values for TT-TG, ignoring the knee size of the individual. Second, in high-grade trochlear dysplasia with a dome-shaped trochlea, measurement of TT-TG has proven to lack precision and reliability. The purpose of this examination was to establish a knee rotation angle, independent of the size of the individual knee and unaffected by a dysplastic trochlea. A total of 114 consecutive MRI scans of knee joints were analysed by two observers, retrospectively. Of these, 59 were obtained from patients with trochlear dysplasia, and another 55 were obtained from patients presenting with a different pathology of the knee joint. Trochlear dysplasia was classified into low grade and high grade. TT-TG was measured according to the method described by Schoettle et al. In addition, a modified knee rotation angle was assessed. Interobserver reliability of the knee rotation angle and its correlation with TT-TG was calculated. The knee rotation angle showed good correlation with TT-TG in the readings of observer 1 and observer 2. Interobserver correlation of the parameter showed excellent values for the scans with normal trochlea, low-grade and high-grade trochlear dysplasia, respectively. All calculations were statistically significant (p < 0.05). The knee rotation angle might meet the requirements for precise diagnostics in knee realignment surgery. Unlike TT-TG, this parameter seems not to be affected by a dysplastic trochlea. In addition, the dimensionless parameter is independent of the knee size of the individual. II.

  17. Long-term outcome of accessory nerve to suprascapular nerve transfer in obstetric brachial plexus lesion: functional, morphological, and electrophysiological results.

    PubMed

    Gmeiner, Matthias; Topakian, Raffi; Göschl, Manuel; Wurm, Sarah; Holzinger, Anita; van Ouwerkerk, Willem J R; Holl, Kurt

    2015-09-01

    An accessory to suprascapular nerve (XIN-SSN) transfer is considered in patients with obstetric brachial plexus lesion who fail to recover active shoulder external rotation. The aim of this study was to evaluate the quality of extraplexal suprascapular nerve neurotization and to perform a detailed analysis of the infraspinatus muscle (IM) and shoulder external rotation. A XIN-SSN transfer was performed in 14 patients between 2000 and 2007. Patients had been operated at the age of 3.7 ± 2.8 years. Follow-up examinations were conducted up to 8.5 ± 2.5 years. Magnetic resonance imaging was performed to investigate muscle trophism. Fatty muscle degeneration of the IM was classified according to the Goutallier classification. We conducted nerve conduction velocity studies of the suprascapular nerve and needle electromyography of the IM to assess pathologic spontaneous activity and interference patterns. Active glenohumeral shoulder external rotation and global shoulder function were evaluated using the Mallet score. Postoperatively, growth of the IM increased equally on the affected and unaffected sides, although significant differences of muscle thickness persisted over time. There was only grade 1 or 2 fatty degeneration pre- and postoperatively. Electromyography of the IM revealed a full interference pattern in all except one patient, and there was no pathological spontaneous activity. Glenohumeral external rotation as well as global shoulder function increased significantly. Our results indicate that the anastomosis after XIN-SSN transfer is functional and that successful reinnervation of the infraspinatus muscle may enable true glenohumeral active external rotation.

  18. Functional Outcome and Healing of Large and Massive Rotator Cuff Tears Repaired With a Load-Sharing Rip-Stop Construct.

    PubMed

    Noyes, Matthew P; Ladermann, Alexandre; Denard, Patrick J

    2017-09-01

    To prospectively review functional outcomes and healing rates of large and massive rotator cuff tears repaired with a load-sharing rip-stop (LSRS) technique. Twenty-one consecutive patients underwent arthroscopic rotator cuff repair with an LSRS construct between January and December 2014. Seventeen patients with a minimum of 2 years' follow-up were included. Four patients did not complete clinical evaluations and functional outcome scores at a minimum of 2 years' follow-up and were lost to follow-up. Ultrasound imaging was used to assess for rotator cuff healing at a minimum of 6 months postoperatively. Range of motion, strength, and functional outcome scores were evaluated at final follow-up. Mean active forward elevation improved from 109° preoperatively to 153° postoperatively, and mean supraspinatus strength improved by 1 strength grade, from 3.5 preoperatively to 4.4 postoperatively. When we compared preoperative and postoperative values, the American Shoulder and Elbow Surgeons score improved from 40.8 to 89.5, the Single Assessment Numeric Evaluation score improved from 32.8 to 83.1, the Simple Shoulder Test score improved from 3.8 to 10.3, and the pain score on a visual analog scale decreased from 4.8 to 0.8 (P < .001). Of 17 patients, 13 (82%) were satisfied with their outcomes. Ultrasound evaluation 6 months after surgery showed complete healing in 53%, partial healing in 29%, and no healing in 18%. The LSRS construct showed satisfactory functional outcomes with reasonable healing rates in an otherwise challenging subset of rotator cuff tears. This construct may be an alternative for tears not amenable to double-row repair. Level IV, therapeutic case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Rotator Cuff Repair in Adolescent Athletes.

    PubMed

    Azzam, Michael G; Dugas, Jeffrey R; Andrews, James R; Goldstein, Samuel R; Emblom, Benton A; Cain, E Lyle

    2018-04-01

    Rotator cuff tears are rare injuries in adolescents but cause significant morbidity if unrecognized. Previous literature on rotator cuff repairs in adolescents is limited to small case series, with few data to guide treatment. Adolescent patients would have excellent functional outcome scores and return to the same level of sports participation after rotator cuff repair but would have some difficulty with returning to overhead sports. Case series; Level of evidence 4. A retrospective search of the practice's billing records identified all patients participating in at least 1 sport who underwent rotator cuff repair between 2006 and 2014 with an age <18 years at the time of surgery and a minimum follow-up of 2 years. Clinical records were evaluated for demographic information, and telephone follow-up was obtained regarding return to play, performance, other surgery and complications, a numeric pain rating scale (0-10) for current shoulder pain, American Shoulder and Elbow Surgeons (ASES) Shoulder Assessment Form, and the Western Ontario Rotator Cuff Index. Thirty-two consecutive adolescent athletes (28 boys and 4 girls) with a mean age of 16.1 years (range, 13.2-17.9 years) met inclusion criteria. Twenty-nine patients (91%) had a traumatic event, and 27 of these patients (93%) had no symptoms before the trauma. The most common single tendon injury was to the supraspinatus (21 patients, 66%), of which 2 were complete tendon tears, 1 was a bony avulsion of the tendon, and 18 were high-grade partial tears. Fourteen patients (56%) underwent single-row repair of their rotator cuff tear, and 11 (44%) underwent double-row repair. All subscapularis injuries were repaired in open fashion, while all other tears were repaired arthroscopically. Twenty-seven patients (84%) completed the outcome questionnaires at a mean 6.2 years after surgery (range, 2-10 years). The mean ASES score was 93 (range, 65-100; SD = 9); mean Western Ontario Rotator Cuff Index, 89% (range, 60%-100%; SD = 13%); and mean numeric pain rating, 0.3 (range, 0-3; SD = 0.8). Overall, 25 patients (93%) returned to the same level of play or higher. Among overhead athletes, 13 (93%) were able to return to the same level of play, but 8 (57%) were forced to change positions. There were no surgical complications, but 2 patients did undergo a subsequent operation. Surgical repair of high-grade partial-thickness and complete rotator cuff tears yielded successful outcomes among adolescents, with excellent functional outcomes at midterm follow-up. However, overhead athletes may have difficulty playing the same position after surgery.

  20. The dishonest dean's letter: an analysis of 532 dean's letters from 99 U.S. medical schools.

    PubMed

    Edmond, M; Roberson, M; Hasan, N

    1999-09-01

    To quantify the censure of potentially negative information in dean's letters. Concordance between 532 dean's letters and the corresponding transcripts was determined for six variables (failing grade in a preclinical course, marginal preclinical course grade, failing grade for a clinical rotation, marginal clinical rotation grade, leave of absence, and requirement to repeat an entire year of medical school). The evaluated variables were not found in the dean's letters 27% to 50% of the time that they were present on the transcripts. In three of nine instances (33%), a failing grade in a clinical rotation was not included. Four students had been required to repeat an entire year, but this was noted in only two cases. In toto, 35 of 104 (34%) of the variables identified on the transcripts were not reported. In addition, deans were significantly less likely to report a student's USMLE 1 score if the score was at or below the 20th percentile (p = .03). Some deans suppress negative information in their letters and potentially obfuscate the residency selection process.

  1. Defensive Gin-Trap Closure Response of Tenebrionid Beetle, Zophobas atratus, Pupae

    PubMed Central

    Ichikawa, Toshio; Kurauchi, Toshiaki; Yamawaki, Yoshifumi

    2012-01-01

    Pupae of the beetle Zophobas atratus Fab. (Coleoptera: Tenebrionidae) have jaws called gin traps on the lateral margin of their jointed abdominal segments. When a weak tactile stimulation was applied to the intersegmental region between the two jaws of a gin trap in a resting pupa, the pupa rapidly closed and reopened single or multiple gin traps adjacent to the stimulated trap for 100200 ms. In response to a strong stimulation, a small or large rotation of the abdominal segments occurred after the rapid closure of the traps. Analyses of trajectory patterns of the last abdominal segment during the rotations revealed that the rotational responses were graded and highly variable with respect to the amplitudes of their horizontal and vertical components. The high variability of these rotational responses is in contrast with the low variability (or constancy) of abdominal rotations induced by the tactile stimulation of cephalic and thoracic appendages. Since the closed state of the gin traps lasts only for a fraction of a second, the response may mainly function to deliver a “painful” stimulus to an attacker rather than to cause serious damage. PMID:23448309

  2. Defensive gin-trap closure response of tenebrionid beetle, Zophobas atratus, pupae.

    PubMed

    Ichikawa, Toshio; Kurauchi, Toshiaki; Yamawaki, Yoshifumi

    2012-01-01

    Pupae of the beetle Zophobas atratus Fab. (Coleoptera: Tenebrionidae) have jaws called gin traps on the lateral margin of their jointed abdominal segments. When a weak tactile stimulation was applied to the intersegmental region between the two jaws of a gin trap in a resting pupa, the pupa rapidly closed and reopened single or multiple gin traps adjacent to the stimulated trap for 100200 ms. In response to a strong stimulation, a small or large rotation of the abdominal segments occurred after the rapid closure of the traps. Analyses of trajectory patterns of the last abdominal segment during the rotations revealed that the rotational responses were graded and highly variable with respect to the amplitudes of their horizontal and vertical components. The high variability of these rotational responses is in contrast with the low variability (or constancy) of abdominal rotations induced by the tactile stimulation of cephalic and thoracic appendages. Since the closed state of the gin traps lasts only for a fraction of a second, the response may mainly function to deliver a "painful" stimulus to an attacker rather than to cause serious damage.

  3. Post-operative rotator cuff integrity, based on Sugaya's classification, can reflect abduction muscle strength of the shoulder.

    PubMed

    Yoshida, Masahito; Collin, Phillipe; Josseaume, Thierry; Lädermann, Alexandre; Goto, Hideyuki; Sugimoto, Katumasa; Otsuka, Takanobu

    2018-01-01

    Magnetic resonance (MR) imaging is common in structural and qualitative assessment of the rotator cuff post-operatively. Rotator cuff integrity has been thought to be associated with clinical outcome. The purpose of this study was to evaluate the inter-observer reliability of cuff integrity (Sugaya's classification) and assess the correlation between Sugaya's classification and the clinical outcome. It was hypothesized that Sugaya's classification would show good reliability and good correlation with the clinical outcome. Post-operative MR images were taken two years post-operatively, following arthroscopic rotator cuff repair. For assessment of inter-rater reliability, all radiographic evaluations for the supraspinatus muscle were done by two orthopaedic surgeons and one radiologist. Rotator cuff integrity was classified into five categories, according to Sugaya's classification. Fatty infiltration was graded into four categories, based on the Fuchs' classification grading system. Muscle hypotrophy was graded as four grades, according to the scale proposed by Warner. The clinical outcome was assessed according to the constant scoring system pre-operatively and 2 years post-operatively. Of the sixty-two consecutive patients with full-thickness rotator cuff tears, fifty-two patients were reviewed in this study. These subjects included twenty-three men and twenty-nine women, with an average age of fifty-seven years. In terms of the inter-rater reliability between orthopaedic surgeons, Sugaya's classification showed the highest agreement [ICC (2.1) = 0.82] for rotator cuff integrity. The grade of fatty infiltration and muscle atrophy demonstrated good agreement, respectively (0.722 and 0.758). With regard to the inter-rater reliability between orthopaedic surgeon and radiologist, Sugaya's classification showed good reliability [ICC (2.1) = 0.70]. On the other hand, fatty infiltration and muscle hypotrophy classifications demonstrated fair and moderate agreement [ICC (2.1) = 0.39 and 0.49]. Although no significant correlation was found between overall post-operative constant score and Sugaya's classification, Sugaya's classification indicated significant correlation with the muscle strength score. Sugaya's classification showed repeatability and good agreement between the orthopaedist and radiologist, who are involved in the patient care for the rotator cuff tear. Common classification of rotator cuff integrity with good reliability will give appropriate information for clinicians to improve the patient care of the rotator cuff tear. This classification also would be helpful to predict the strength of arm abduction in the scapular plane. IV.

  4. [Surgical treatment of pronation and supination external rotation trimalleolar fractures].

    PubMed

    Xu, Ye-qing; Zhan, Bei-lei; He, Fei-xiong; Wei, Hong-da

    2008-04-01

    To explore the operative method and its clinical effects of pronation and supination external rotation trimalleolar fractures. From March 2000 to July 2006,42 patients of the pronation and supination external rotation trimalleolar fractures treated with open reduction and internal fixation. Thirty-one were males and 11 were females,with an average age of 40.5 years (from 19 to 76 years). Four cases were open fractures and 38 cases close fractures. The fractures were classified as pronation-external rotation (grade IV) injury in 18 cases and supination-external rotation (grade IV)in 24 cases according to the system of Lauge-Hansen. The time of injury to operation was 2 hours to 27 days. The medial, lateral and posterior malleolus were exposed by standard anteromedial and Gatellier-Chastang approaches. The reduction and internal fixation started with the posterior,then the medial and the lateral malleolus and distal tibiofibular syndesmosis in sequence. The anteroposterior, lateral and mostise X-ray films were taken after operation. All the patients were followed up for an average time of 13.5 months(from 6 to 24 months). The time of union was from 12 to 16 weeks. The results were excellent in 20,good in 16, fair in 4 and poor in 2 cases according to Baird-Jackson ankle scoring system based on pain, stability, walking ability,range of motion and radiological manifestations. The excellent and good rate was 85.7%. There were no infection,malunion and nonunion of the fractures except that the inserted screw to distal tibiofibular syndesmosis was broken in 1 case. The key of operative treatment is to restore the anatomy of ankle and to regain the ankle function maximally.

  5. Quadratic Solid⁻Shell Finite Elements for Geometrically Nonlinear Analysis of Functionally Graded Material Plates.

    PubMed

    Chalal, Hocine; Abed-Meraim, Farid

    2018-06-20

    In the current contribution, prismatic and hexahedral quadratic solid⁻shell (SHB) finite elements are proposed for the geometrically nonlinear analysis of thin structures made of functionally graded material (FGM). The proposed SHB finite elements are developed within a purely 3D framework, with displacements as the only degrees of freedom. Also, the in-plane reduced-integration technique is combined with the assumed-strain method to alleviate various locking phenomena. Furthermore, an arbitrary number of integration points are placed along a special direction, which represents the thickness. The developed elements are coupled with functionally graded behavior for the modeling of thin FGM plates. To this end, the Young modulus of the FGM plate is assumed to vary gradually in the thickness direction, according to a volume fraction distribution. The resulting formulations are implemented into the quasi-static ABAQUS/Standard finite element software in the framework of large displacements and rotations. Popular nonlinear benchmark problems are considered to assess the performance and accuracy of the proposed SHB elements. Comparisons with reference solutions from the literature demonstrate the good capabilities of the developed SHB elements for the 3D simulation of thin FGM plates.

  6. Possible ambiguities when testing viscosity in compendial monographs - characterisation of grades of cellulose ethers.

    PubMed

    Doelker, E

    2010-10-01

    The European Pharmacopoeia (Ph. Eur.) monographs for the water-soluble cellulose ethers require viscosity determination, either in the "Tests" section or in the non-mandatory "Functionality-related characteristics" section. Although the derivatives are chemically closely related and used for similar applications, the viscosity tests strongly differ. Some monographs generically speak of the rotating viscometer method (2.2.10) and a fixed shear rate (e.g. 10 s-1), which would necessitate an absolute measuring system, while others recommend the capillary viscometer method for product grades of less than 600 mPa∙s and the rotating viscometer method and given operating conditions for grades of higher nominal viscosity. Viscometer methods also differ between the United States Pharmacopeia/National Formulary (USP/NF) and the Japanese Pharmacopoeia (JP) monographs. In addition, for some cellulose ethers the tests sometimes diverge from one pharmacopoeia to the other, although the three compendiums are in a harmonisation process. But the main issue is that the viscometer methods originally employed by the product manufacturers are often not those described in the corresponding monographs and generally vary from one manufacturer to the other. The aim of this study was therefore to investigate whether such a situation could invalidate the present pharmacopoeial requirements. 2 per cent solutions of several viscosity grades of hydroxyethylcellulose, hypromellose and methylcellulose were prepared and their (apparent) viscosity determined using both relative and absolute viscometer methods. The viscometer method used not only affects the measured viscosity but experimental values generally do not correspond to the product nominal viscosities. It emerges that, in contrast to Newtonian solutions (i.e. those of grades of up to ca. 50 mPa∙s nominal viscosity), some of the viscometer methods currently specified in the monographs are not able unambiguously to characterise the grades exhibiting non-Newtonian behaviour. It is also concluded that, unless the various manufacturers redefine their product viscosity grades using a single compendial test, two strategies could be adopted, both based on the operating conditions specified in the labeling (i.e those of the manufacturer), the test appearing either in the mandatory section if this is acceptable to the pharmacopoeia (like in some USP/NF monographs) or, for the Ph. Eur., in the "Functionality-related characteristics" section.

  7. The Effects of Using Google SketchUp on the Mental Rotation Skills of Eighth Grade Students

    ERIC Educational Resources Information Center

    Erkoc, Mehmet Fatih; Gecu, Zeynep; Erkoc, Cigdem

    2013-01-01

    The aim of this study is to investigate the effectiveness of Google SketchUp, which is a computer aided design (CAD) software, on the Mental Rotation Skills of eighth grade students. For this purpose, in the spring semester of the 2011-2012 academic year, a treatment was conducted with 62 students comprised of 8A and 8B classes in the GSD…

  8. Depth vs. Breadth: Talent Management for Special Warfare

    DTIC Science & Technology

    2016-12-01

    discuss the relevant aspects of how competitive sports teams think about and manage the inevitable churn of their most talented players ; I will...leadership—the research determines that the current method of rotating field grade officers through key jobs every 12–24 months is antithetical to the...interviews with former four- star commanders and Defense Department leadership—the research determines that the current method of rotating field grade

  9. CONSERVATIVE MANAGEMENT OF AN ISOLATED GRADE III LATERAL COLLATERAL LIGAMENT INJURY IN AN ADOLESCENT MULTI-SPORT ATHLETE: A CASE REPORT

    PubMed Central

    Haddad, M. Alex; Budich, Justin M.; Eckenrode, Brian J.

    2016-01-01

    ABSTRACT Study design Case report Background Isolated, grade III lateral collateral ligament knee injuries are an uncommon traumatic injury with little guidance available in the literature for conservative management and prognosis for return to sport. The purpose of this case report is to describe the clinical decision-making in both differential diagnosis and physical therapy management of an isolated grade III lateral collateral ligament sprain in an adolescent multi-sport high school athlete. Case Description A 16 year-old male, high school, multi-sport athlete (cross country, wrestling, track and field) sustained a traumatic knee injury during a wrestling match when his involved lower extremity was forcefully externally rotated by his opponent. Initial clinical presentation revealed pain and increased laxity with varus stress testing of the left knee, which was subsequently identified via MRI as a complete lateral collateral ligament rupture (grade III). A conservative physical therapy program was developed targeting the active and neuromuscular subsystems, theorized to compensate for the lack of an intact lateral collateral ligament. Outcomes The subject attended 18 visits of physical therapy over a period of 12 weeks. His rehabilitation program focused on functional strengthening of the posterolateral corner, enhancement of neuromuscular control, and graded progression to sports specific drills. Return to play decisions were based on a combination of lower extremity functional performance measures, condition specific outcome measures and subjective performance on sports specific tasks. At discharge from physical therapy, he reported 0/10 pain, scored a 76/80 on the Lower Extremity Functional Scale, and was able to return to competitive track and field events. Discussion Few descriptions in the literature exist for the conservative management of isolated, grade III lateral collateral ligament injuries. A program of selective functional strengthening, proprioceptive training, and graded sport specific activities may allow these individuals to return to sport with conservative management. Levels of Evidence 4 (Single Case Report) PMID:27525183

  10. Application of a computer model to predict optimum slaughter end points for different biological types of feeder cattle.

    PubMed

    Williams, C B; Bennett, G L

    1995-10-01

    A bioeconomic model was developed to predict slaughter end points of different genotypes of feeder cattle, where profit/rotation and profit/day were maximized. Growth, feed intake, and carcass weight and composition were simulated for 17 biological types of steers. Distribution of carcass weight and proportion in four USDA quality and five USDA yield grades were obtained from predicted carcass weights and composition. Average carcass value for each genotype was calculated from these distributions under four carcass pricing systems that varied from value determined on quality grade alone to value determined on yield grade alone. Under profitable market conditions, rotation length was shorter and carcass weights lighter when the producer's goal was maximum profit/day, compared with maximum profit/rotation. A carcass value system based on yield grade alone resulted in greater profit/rotation and in lighter and leaner carcasses than a system based on quality grade alone. High correlations ( > .97) were obtained between breed profits obtained with different sets of input/output prices and carcass price discount weight ranges. This suggests that breed rankings on the basis of breed profits may not be sensitive to changes in input/output market prices. Steers that were on a grower-stocker system had leaner carcasses, heavier optimum carcass weight, greater profits, and less variation in optimum carcass weights between genotypes than steers that were started on a high-energy finishing diet at weaning. Overall results suggest that breed choices may change with different carcass grading and value systems and postweaning production systems. This model has potential to provide decision support in marketing fed cattle.

  11. Early postoperative repair status after rotator cuff repair cannot be accurately classified using questionnaires of patient function and isokinetic strength evaluation.

    PubMed

    Colliver, Jessica; Wang, Allan; Joss, Brendan; Ebert, Jay; Koh, Eamon; Breidahl, William; Ackland, Timothy

    2016-04-01

    This study investigated if patients with an intact tendon repair or partial-thickness retear early after rotator cuff repair display differences in clinical evaluations and whether early tendon healing can be predicted using these assessments. We prospectively evaluated 60 patients at 16 weeks after arthroscopic supraspinatus repair. Evaluation included the Oxford Shoulder Score, 11-item version of the Disabilities of the Arm, Shoulder and Hand, visual analog scale for pain, 12-item Short Form Health Survey, isokinetic strength, and magnetic resonance imaging (MRI). Independent t tests investigated clinical differences in patients based on the Sugaya MRI rotator cuff classification system (grades 1, 2, or 3). Discriminant analysis determined whether intact repairs (Sugaya grade 1) and partial-thickness retears (Sugaya grades 2 and 3) could be predicted. No differences (P < .05) existed in the clinical or strength measures. Although discriminant analysis revealed the 11-item version of the Disabilities of the Arm, Shoulder and Hand produced a 97% true-positive rate for predicting partial thickness retears, it also produced a 90% false-positive rate whereby it incorrectly predicted a retear in 90% of patients whose repair was intact. The ability to discriminate between groups was enhanced with up to 5 variables entered; however, only 87% of the partial-retear group and 36% of the intact-repair group were correctly classified. No differences in clinical scores existed between patients stratified by the Sugaya MRI classification system at 16 weeks. An intact repair or partial-thickness retear could not be accurately predicted. Our results suggest that correct classification of healing in the early postoperative stages should involve imaging. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Chebyshev collocation approach for vibration analysis of functionally graded porous beams based on third-order shear deformation theory

    NASA Astrophysics Data System (ADS)

    Wattanasakulpong, Nuttawit; Chaikittiratana, Arisara; Pornpeerakeat, Sacharuck

    2018-06-01

    In this paper, vibration analysis of functionally graded porous beams is carried out using the third-order shear deformation theory. The beams have uniform and non-uniform porosity distributions across their thickness and both ends are supported by rotational and translational springs. The material properties of the beams such as elastic moduli and mass density can be related to the porosity and mass coefficient utilizing the typical mechanical features of open-cell metal foams. The Chebyshev collocation method is applied to solve the governing equations derived from Hamilton's principle, which is used in order to obtain the accurate natural frequencies for the vibration problem of beams with various general and elastic boundary conditions. Based on the numerical experiments, it is revealed that the natural frequencies of the beams with asymmetric and non-uniform porosity distributions are higher than those of other beams with uniform and symmetric porosity distributions.

  13. Power calculation of grading device in desintegrator

    NASA Astrophysics Data System (ADS)

    Bogdanov, V. S.; Semikopenko, I. A.; Vavilov, D. V.

    2018-03-01

    This article describes the analytical method of measuring the secondary power consumption, necessitated by the installation of a grading device in the peripheral part of the grinding chamber in the desintegrator. There is a calculation model for defining the power input of the disintegrator increased by the extra power demand, required to rotate the grading device and to grind the material in the area between the external row of hammers and the grading device. The work has determined the inertia moments of a cylindrical section of the grading device with armour plates. The processing capacity of the grading device is adjusted to the conveying capacity of the auger feeder. The grading device enables one to increase the concentration of particles in the peripheral part of the grinding chamber and the amount of interaction between particles and armour plates as well as the number of colliding particles. The perforated sections provide the output of the ground material with the proper size granules, which together with the effects of armour plates, improves the efficiency of grinding. The power demand to rotate the grading device does not exceed the admissible value.

  14. [MRI of the rotator cuff: evaluation of a new symptomatologic classification].

    PubMed

    Tavernier, T; Walch, G; Noël, E; Lapra, C; Bochu, M

    1995-05-01

    The different classifications use for the rotator cuff pathology seem to be incomplete. We propose a new classification with many advantages: 1) Differentiate the tendinopathy between less serious (grade 2A) and serious (grade 2B). 2) Recognize the intra-tendinous cleavage of the infra-spinatus associated with complete tear of the supra-spinatus. 3) Differentiate partial and complete tears of the supra-spinatus. We established this classification after a retrospective study of 42 patients operated on for a rotator cuff pathology. Every case had had a preoperative MRI. This classification is simple, reliable, especially for the associated intra tendinous cleavage.

  15. The efficacy of oral non-steroidal anti-inflammatory drugs for rotator cuff tendinopathy: a systematic review and meta-analysis.

    PubMed

    Boudreault, Jennifer; Desmeules, François; Roy, Jean-Sébastien; Dionne, Clermont; Frémont, Pierre; Macdermid, Joy C

    2014-04-01

    To conduct a systematic review and meta-analysis on the efficacy of oral non-steroidal anti-inflammatory drugs for rotator cuff tendinopathy. Systematic review. A literature search was conducted in 4 databases for randomized controlled trials published until 05/2013, comparing the efficacy of oral anti-inflammatory drugs to any other intervention. Studies characteristics were extracted using a standardized form and the methodological quality was evaluated. Results were summarized qualitatively or quantitatively. The mean methodological score of the 12 included studies was 53.6 ± 8.8%. The majority of studies included acute cases and were underpowered to detect differences in adverse events. Compared to a placebo, oral non-steroidal anti-inflammatory drugs were found to provide short-term pain relief (pooled mean difference: -2.69; 95% confidence interval: -1.96 to -3.41) but not function. Oral anti-inflammatory- drugs and corticosteroids injections have similar short-term efficacy in terms of pain reduction as well as in function (pooled standardized mean difference: 0.09; 95% confidence interval: -0.25 to 0.44). Low to moderate grade evidence exists regarding the efficacy of non-steroidal anti-inflammatory drugs for rotator cuff tendinopathy. Oral anti-inflammatory drugs are effective in reducing short-term pain but not function. In terms of pain and function, oral anti-inflammatory drugs in the short term are as effective as corticosteroid injections.

  16. Mobility, strength, and fitness after a graded activity program for patients with subacute low back pain. A randomized prospective clinical study with a behavioral therapy approach.

    PubMed

    Lindström, I; Ohlund, C; Eek, C; Wallin, L; Peterson, L E; Nachemson, A

    1992-06-01

    Patients with nonspecific mechanical low back pain (n = 103), examined by an orthopaedic surgeon and a social worker, were randomized to an activity group (n = 51) and a control group (n = 52). Patients with defined orthopaedic, medical, or psychiatric diagnoses were excluded before randomization. No patients were excluded due to place of birth or difficulties in speaking or understanding the Swedish language. The purpose of the study was to compare mobility, strength and fitness after traditional care and after traditional care plus a graded activity program with a behavioral therapy approach. A graded activity program, with a behavioral therapy approach was given under the guidance of a physical therapist. The endpoint of the graded activity program was return to work. This program significantly increased mobility, strength, and fitness more than could be explained by only a time recovery effect, especially in males. The patients in the activity group returned to work earlier than did the patients in the control group. Spinal rotation, abdominal muscle endurance time and lifting capacity were significantly correlated to rate of return to work. Traditional care plus a graded activity program were superior to only traditional care, evaluated in terms of mobility, strength and fitness. The graded activity program proved to be a successful method of restoring occupational function and facilitating return to work in subacute low back pain patients. The patients in the graded activity program learned that it is safe to move, while regaining function.

  17. Hip Joint Effusion-Synovitis Is Associated With Hip Pain and Sports/Recreation Function in Female Professional Ballet Dancers.

    PubMed

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Cook, Jill

    2018-03-23

    To compare hip joint effusion-synovitis prevalence in professional ballet dancers with nondancing athletes and to evaluate the relationship between effusion-synovitis and clinical measures and cartilage defects. Case-control study. Elite ballet and sport. Forty-nine professional ballet dancers and 49 age-matched and sex-matched athletes. Group (dancers/athletes), sex, age, years of training, Copenhagen Hip and Groin Outcome Scores (HAGOSs), hip rotation range of motion (ROM), generalized joint hypermobility (GJH), and hip cartilage defect scores. Hip joint effusion-synovitis (absent, grade 1 = 2-4 mm, grade 2 = >4 mm) scored with 3-Tesla magnetic resonance imaging. Hip joint effusion-synovitis was found in 22 (45%) dancers and 13 (26.5%) athletes (P = 0.06). Grade 2 effusion-synovitis was only found in dancers (n = 8, r = 0.31, P = 0.009). The prevalence of effusion-synovitis was similar in men (n = 11, 26%) and women (n = 24, 43%, P = 0.09). Female dancers with effusion-synovitis had lower HAGOS pain (r = 0.63, P = 0.001) and sports/recreation scores (r = 0.66, P = 0.001) compared with those without effusion-synovitis. The HAGOS scores were not related to effusion-synovitis in male dancers or female and male athletes (P > 0.01 for all). Effusion-synovitis was not related to hip ROM, GJH, or cartilage defect scores (P > 0.05 for all). Hip joint effusion-synovitis was related to higher levels of pain and lower sports/recreation function in female ballet dancers. Effusion-synovitis was not related to hip rotation ROM, GJH or cartilage defects. Larger sized joint effusion-synovitis was exclusively found in dancers.

  18. [Manipulative reduction and percutaneous Kirschner wire internal fixation for grade IV supination-external rotation ankle fractures].

    PubMed

    Li, Jia; Sun, Jin-Ke; Wang, Chen-Lin

    2017-06-25

    To investigate surgical skills and clinical effects of manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures. From May 2013 to October 2016, 35 patients with grade IV supination-external rotation ankle fractures were treated with percutaneous Kirschner wire internal fixation, involving 22 males and 13 females with an average age of 38.2 years ranged from 18 to 65 years old. The time from injury to operation ranged from 2 h to 10 d with an average of 5 d. Reduction quality was assessed by Burwell-Charnley radiological criteria. Baird-Jackson ankle scoring system was used to assess clinical effects. Thirty-three patients were followed up from 10 to 28 months with an average of 14 months. Fracture healing time ranged from 10 to 18 weeks with an average of 12 weeks. According to Burwell-Charnley radiological criteria, 30 cases were obtained anatomic reduction, 3 cases moderate. According to Baird-Jackson ankle scoring system, total score was 93.8±5.4, 17 cases got excellent result, 12 good, 2 fair and 2 poor. Manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures has advantages of reliable efficacy, less complications. But higher require techniques were required for closed reduction. It is not suitable for severe crushed fracture and compressive articular surface fracture.

  19. Comparison of 2 oral ultrasonography contrast agents: simethicone-coated cellulose and simethicone-water rotation in improving pancreatic visualization.

    PubMed

    Ishigami, Kousei; Abu-Yousef, Dina M; Kao, Simon C S; Abu-Yousef, Monzer M

    2014-06-01

    The purpose of this study was to prospectively compare the efficacy of 2 oral ultrasonography (US) contrast agents (simethicone-water rotation [SWR] and simethicone-coated cellulose [SCC]) in improving visualization of the pancreas. Two sessions (SWR and SCC) of transabdominal US studies were performed on 38 healthy volunteers. In each session, US images were obtained in precontrast supine and upright positions and postcontrast supine and upright positions. The visualization of the pancreas was graded on a scale of 1 to 5 (1 = nonvisualization, 5 = excellent visualization), grading the head, body, and tail separately. In the supine position, SWR significantly improved the visualization of the pancreatic head, body, and tail, whereas there were no significant differences between SCC and precontrast images. Simethicone-water rotation showed significantly better visualization than SCC. The average scores of the head, body, and tail of the pancreas that graded 4 or more were 15.8% of precontrast, 21.1% of SCC, and 50% of SWR. In the upright position, both SWR and SCC significantly improved the visualization of the pancreas, except for the pancreatic body on SCC. There were no significant differences between SWR and SCC. The average scores that graded 4 or more were 26.3% of precontrast, 57.9% of SCC, and 65.8% of SWR. Simethicone-water rotation was more effective than SCC in improving the visualization of the pancreas.

  20. Therapeutic outcomes of muscular advancement by an arthroscopic-assisted modified Debeyre-Patte procedure for irreparable large and massive rotator cuff tears.

    PubMed

    Morihara, Toru; Kida, Yoshikazu; Furukawa, Ryuhei; Sukenari, Tsuyoshi; Kabuto, Yukichi; Kurokawa, Masao; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2018-05-01

    In cases of the large or massive rotator cuff tears, retear rates after rotator cuff repairs remain high. We introduced an arthroscopic-assisted modified Debeyre-Patte procedure which enables to decrease the tension of torn rotator cuff by sliding supraspinatus and infraspinatus laterally keeping fascia connection to the rhomboids. The objective of this study was to examine the clinical outcomes and retear rates after an arthroscopic-assisted modified Debeyre-Patte procedure for irreparable large and massive rotator cuff tears. Thirty-three rotator cuff tear patients (34 shoulders) were selected. These patients underwent arthroscopic-assisted modified Debeyre-Patte procedures and were observed postoperatively for at least 24 months. Magnetic resonance imaging (MRI) was used to evaluate the preoperative location of the torn rotator cuff stump and fatty infiltration of the muscles composing the rotator cuff, as well as the repaired rotator cuffs. Shoulder functional evaluations through the use of the Constant and Murley scores and the University of California Los Angeles (UCLA) shoulder score were compared before and after surgery, and the preoperative global fatty degeneration index (GFDI) was compared between retear and healed shoulders. MRI showed that 77% of shoulders were healed and 23% exhibited retear postoperatively. The mean preoperative GFDI was 1.99 among the 26 healed shoulders and 2.54 among the 8 retear shoulders (p < .05). When the Goutallier's classification was grade 3 or lower for all 3 cuff muscles for fatty infiltration, the retear rate was 14.3%. The mean Constant and Murley scores in healed and retear groups respectively improved from 34.7 ± 15.8, 30.0 ± 15.1 points (p = 0.47) preoperatively to 70.8 ± 8.3, 53.9 ± 14.0 points (p < .001), and UCLA scores in healed and retear groups from 13.8 ± 3.9, 12.4 ± 5.0 points (p = 0.46) preoperatively to 32.8 ± 2.7, 28.4 ± 3.6 points (p < .001). The clinical outcomes of healed shoulders after the arthroscopic-assisted modified Debeyre-Patte procedure were favorable. If the torn rotator cuff stump is retracted near the glenoid fossa, and the rotator cuff muscle scored Goutallier grade 3 or lower, this modified Debeyre-Patte procedure would be a viable option. Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  1. A case of iatrogenic stress? Results of the RCOG August rotation survey.

    PubMed

    Cooke, M; Morris, E

    2014-10-01

    Although there are a number of studies of patient safety during the August rotation, they often focus on newly qualified doctors. It remains unclear whether negative impacts are due to doctors' inexperience, lack of technical skill or other aspects of rotation. This study used an electronic survey to seek the views of doctors working in obstetrics and gynaecology in the UK. A total of 1,879 responses were received. The August rotation was felt to be a stressful time, with a negative effect on patient care (82%) and safety (73%), lasting up to 1 month (62%). Although reducing services was thought to be helpful, there was strong support for staggering the rotation by grade (80%). This would ensure availability of doctors to cover services during the induction period, which should improve patient care and reduce staff stress. In addition, intensive skills training for junior staff and a supportive culture during the 1st month could optimise the integration and performance of doctors of all grades.

  2. Owner Evaluation of a CORA-Based Leveling Osteotomy for Treatment of Cranial Cruciate Ligament Injury in Dogs.

    PubMed

    Kishi, Erin N; Hulse, Don

    2016-05-01

    To evaluate a center of rotation of angulation (CORA)-based leveling osteotomy for cranial cruciate ligament injury in dogs. Retrospective case series. Dogs (n=70). Medical records (March 2011 to March 2012) of dogs diagnosed with a cranial cruciate ligament (CCL) injury treated with a CORA-based leveling osteotomy and stabilized using a bone plate and headless compression screw were reviewed. Radiographs were reviewed for tibial plateau angle and radiographic healing at final evaluation graded on a 5-point scale. Follow-up for a minimum of 6 months postoperatively was conducted by owner completion of a questionnaire regarding their dog's function after surgery. Based on owner responses, clinical outcomes were established. CORA-based leveling osteotomy was used for 70 stifles with CCL injury. The mean time to final radiographic recheck was 107 days (range, 32-424 days). Radiographic healing scores were 42 dogs (69%) with grade 4, 17 dogs (28%) with grade 3, and 2 dogs (3%) with grade 2. The mean time to follow-up was 11.9 months (range 6-18 months). Fifty-four of the 70 (77%) dogs had full function, 13 (19%) had acceptable function, and 3 (4%) had unacceptable function. Complications occurred in 11 stifles (16%), including 3 incisional, 6 late-onset meniscal tears, and 2 implant related. The described method of a CORA-based leveling osteotomy can be successfully performed for treatment of CCL injury in dogs. At the time of mid-term and long-term owner follow-up, most dogs in this case series had returned to full function. © Copyright 2016 by The American College of Veterinary Surgeons.

  3. Radiographic progression of arthritic changes in shoulders with degenerative rotator cuff tears.

    PubMed

    Chalmers, Peter N; Salazar, Dane H; Steger-May, Karen; Chamberlain, Aaron M; Stobbs-Cucchi, Georgia; Yamaguchi, Ken; Keener, Jay D

    2016-11-01

    Very little longitudinal information has been available regarding the relationship of cuff tears and arthritis. The purpose of this study was to determine the midterm risk of and risk factors for rotator cuff tear arthropathy progression in a cohort of subjects with an asymptomatic rotator cuff tear. Baseline (visit 1), 5-year (visit 2), and most recent follow-up (visit 3) radiographs were reviewed in a cohort of 105 subjects enrolled for longitudinal surveillance of asymptomatic degenerative rotator cuff tears and 33 controls. The radiographs were assessed in a blinded, randomized fashion by 3 observers who graded glenohumeral arthritic changes using the Hamada scores, Samilson-Prieto (SPO) scores, and acromiohumeral interval (AHI). Osteoarthritis (SPO classification), cuff tear arthropathy (Hamada classification), and AHI progressed between visits 1 and 3 (median, 8 years; P < .001 in all cases). SPO progression was not significantly different for partial- vs. full-thickness vs. control baseline tear types (P = .19). Both full-thickness and partial-thickness tears had greater progression in Hamada scores than controls did in the first 5 years of follow-up (P = .02 and P = .03, respectively), but scores did not differ between partial- and full-thickness tears. Tears with and without enlargement did not differ in progression in SPO grade, Hamada grade, or AHI. Glenohumeral arthritic changes progress significantly but remain minimal within an 8-year period in early to moderate degenerative cuff disease. Whereas the presence of a rotator cuff tear influences progression in Hamada grade, the magnitude of radiographic progression is not influenced by tear severity or enlargement at midterm time points. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Quantitative and Qualitative Change in Children's Mental Rotation Performance

    ERIC Educational Resources Information Center

    Geiser, Christian; Lehmann, Wolfgang; Corth, Martin; Eid, Michael

    2008-01-01

    This study investigated quantitative and qualitative changes in mental rotation performance and solution strategies with a focus on sex differences. German children (N = 519) completed the Mental Rotations Test (MRT) in the 5th and 6th grades (interval: one year; age range at time 1: 10-11 years). Boys on average outperformed girls on both…

  5. Observation and Analysis of N[subscript 2]O Rotation-Vibration Spectra: A Physical Chemistry Laboratory Experiment

    ERIC Educational Resources Information Center

    Bryant, Mark S.; Reeve, Scott W.; Burns, William A.

    2008-01-01

    The linear molecule N[subscript 2]O is presented as an alternative gas-phase species for the ubiquitous undergraduate physical chemistry rotation-vibration spectroscopy experiment. Utilizing a 0.5 cm[superscript -1] resolution teaching grade FTIR spectrometer, 15 vibrational bands, corresponding to 1229 rotation-vibration transitions, have been…

  6. Reverse shoulder arthroplasty with a cementless short metaphyseal humeral implant without a stem: clinical and radiologic outcomes in prospective 2- to 7-year follow-up study.

    PubMed

    Levy, Ofer; Narvani, Ali; Hous, Nir; Abraham, Ruben; Relwani, Jai; Pradhan, Riten; Bruguera, Juan; Sforza, Giuseppe; Atoun, Ehud

    2016-08-01

    Reverse shoulder prostheses are increasingly used in recent years for treatment of glenohumeral arthropathy with deficient rotator cuff. Bone preservation is becoming a major goal in shoulder replacement surgery. Metaphyseal humeral components without a stem were developed to minimize bone resection and preserve bone. This study evaluated the clinical and radiologic outcomes at 2 to 7 years using a novel short metaphyseal reverse total shoulder arthroplasty (rTSA) prosthesis without a diaphyseal stem. Between 2005 and 2010, 102 consecutive patients underwent rTSA with this implant, and 98 (20 men, 78 women) were available for follow-up. Mean age was 74.4 years (range, 38-93 years). Indications were cuff tear arthropathy, 65; fracture sequelae, 12; rheumatoid arthritis, 13; failed rotator cuff repair, 3; cuff deficiency with loosening of anatomic prosthesis, 3; and acute trauma, 2; with 17 of these as revisions. Patients' satisfaction (Subjective Shoulder Value) improved from 8 of 100 to 85 of 100. The Constant score improved from 14 to 59 (age- and sex-adjusted, 86; P < .0001). Range of motion improved from 47° to 129° in elevation, 10° to 51° in external rotation, and 21° to 65° in internal rotation. Radiographic analysis showed no lucencies, subsidence, or stress shielding around the humeral or glenoid components. Glenoid notching was found in 21 patients (18 grade 1-2; 3 grade 3). The short metaphyseal rTSA design without a diaphyseal stem shows encouraging short- to midterm results, with excellent pain relief and shoulder function, restoration of good active range of motion, and high patient satisfaction scores. The design of this implant seems to result in improved rotational movements, low incidence of glenoid notching, and no implant loosening, subsidence, or stress shielding. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Rehabilitation after a grade III latissimus dorsi tear of a soccer player: A case report.

    PubMed

    Fysentzou, Christodoulos

    2016-11-21

    Latissimus dorsi, grade III tendon tears are an uncommon injury. There are very few cases reported in the literature, but most importantly, no cases could be found that relate to soccer. To present a successful, non-operative rehabilitation program for a professional athlete, after a grade III latissimus dorsi tear. A 37 year old healthy, elite professional soccer goalkeeper was injured during a championship game. The athlete fell on his left side with an outstretched and externally rotated upper extremity in order to catch a ball that was going very close to the left pole of his goal-post. After on-field and off-field clinical examinations, the diagnosis was a left latissimus dorsi tendon tear which was later confirmed by MRI as a grade III tear. During the first two weeks, intervention consisted of anti-inflammatory treatment and light therapeutic exercises. As the pain was subsiding and the strength was returning, the treatment shifted to purely strengthening and functional training. Four weeks after the injury, the athlete presented with pain 0/10 in all functional activities and full ROM in both active and passive movements. Before discharge, the athlete underwent a sport specific training program, without any complains, that cleared him to participate in normal training with the rest of the team. Three months after the injury the strength of the player's left shoulder was 5/5 in all movements. The protocol used yielded an accelerated return to sport (soccer) and function compared with other published research after a grade III latissimus dorsi tendon tear. One year later, the goalkeeper was still playing in the same competitive level without any re-injuries or complains, which means that this treatment protocol withstood the test of time.

  8. Inertial rotation measurement with atomic spins: From angular momentum conservation to quantum phase theory

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Yuan, H.; Tang, Z.; Quan, W.; Fang, J. C.

    2016-12-01

    Rotation measurement in an inertial frame is an important technology for modern advanced navigation systems and fundamental physics research. Inertial rotation measurement with atomic spin has demonstrated potential in both high-precision applications and small-volume low-cost devices. After rapid development in the last few decades, atomic spin gyroscopes are considered a promising competitor to current conventional gyroscopes—from rate-grade to strategic-grade applications. Although it has been more than a century since the discovery of the relationship between atomic spin and mechanical rotation by Einstein [Naturwissenschaften, 3(19) (1915)], research on the coupling between spin and rotation is still a focus point. The semi-classical Larmor precession model is usually adopted to describe atomic spin gyroscope measurement principles. More recently, the geometric phase theory has provided a different view of the rotation measurement mechanism via atomic spin. The theory has been used to describe a gyroscope based on the nuclear spin ensembles in diamond. A comprehensive understanding of inertial rotation measurement principles based on atomic spin would be helpful for future applications. This work reviews different atomic spin gyroscopes and their rotation measurement principles with a historical overlook. In addition, the spin-rotation coupling mechanism in the context of the quantum phase theory is presented. The geometric phase is assumed to be the origin of the measurable rotation signal from atomic spins. In conclusion, with a complete understanding of inertial rotation measurements using atomic spin and advances in techniques, wide application of high-performance atomic spin gyroscopes is expected in the near future.

  9. An analytical method for free vibration analysis of functionally graded beams with edge cracks

    NASA Astrophysics Data System (ADS)

    Wei, Dong; Liu, Yinghua; Xiang, Zhihai

    2012-03-01

    In this paper, an analytical method is proposed for solving the free vibration of cracked functionally graded material (FGM) beams with axial loading, rotary inertia and shear deformation. The governing differential equations of motion for an FGM beam are established and the corresponding solutions are found first. The discontinuity of rotation caused by the cracks is simulated by means of the rotational spring model. Based on the transfer matrix method, then the recurrence formula is developed to get the eigenvalue equations of free vibration of FGM beams. The main advantage of the proposed method is that the eigenvalue equation for vibrating beams with an arbitrary number of cracks can be conveniently determined from a third-order determinant. Due to the decrease in the determinant order as compared with previous methods, the developed method is simpler and more convenient to analytically solve the free vibration problem of cracked FGM beams. Moreover, free vibration analyses of the Euler-Bernoulli and Timoshenko beams with any number of cracks can be conducted using the unified procedure based on the developed method. These advantages of the proposed procedure would be more remarkable as the increase of the number of cracks. A comprehensive analysis is conducted to investigate the influences of the location and total number of cracks, material properties, axial load, inertia and end supports on the natural frequencies and vibration mode shapes of FGM beams. The present work may be useful for the design and control of damaged structures.

  10. Magnetic field induced flow pattern reversal in a ferrofluidic Taylor-Couette system

    PubMed Central

    Altmeyer, Sebastian; Do, Younghae; Lai, Ying-Cheng

    2015-01-01

    We investigate the dynamics of ferrofluidic wavy vortex flows in the counter-rotating Taylor-Couette system, with a focus on wavy flows with a mixture of the dominant azimuthal modes. Without external magnetic field flows are stable and pro-grade with respect to the rotation of the inner cylinder. More complex behaviors can arise when an axial or a transverse magnetic field is applied. Depending on the direction and strength of the field, multi-stable wavy states and bifurcations can occur. We uncover the phenomenon of flow pattern reversal as the strength of the magnetic field is increased through a critical value. In between the regimes of pro-grade and retrograde flow rotations, standing waves with zero angular velocities can emerge. A striking finding is that, under a transverse magnetic field, a second reversal in the flow pattern direction can occur, where the flow pattern evolves into pro-grade rotation again from a retrograde state. Flow reversal is relevant to intriguing phenomena in nature such as geomagnetic reversal. Our results suggest that, in ferrofluids, flow pattern reversal can be induced by varying a magnetic field in a controlled manner, which can be realized in laboratory experiments with potential applications in the development of modern fluid devices. PMID:26687638

  11. Magnetic field induced flow pattern reversal in a ferrofluidic Taylor-Couette system.

    PubMed

    Altmeyer, Sebastian; Do, Younghae; Lai, Ying-Cheng

    2015-12-21

    We investigate the dynamics of ferrofluidic wavy vortex flows in the counter-rotating Taylor-Couette system, with a focus on wavy flows with a mixture of the dominant azimuthal modes. Without external magnetic field flows are stable and pro-grade with respect to the rotation of the inner cylinder. More complex behaviors can arise when an axial or a transverse magnetic field is applied. Depending on the direction and strength of the field, multi-stable wavy states and bifurcations can occur. We uncover the phenomenon of flow pattern reversal as the strength of the magnetic field is increased through a critical value. In between the regimes of pro-grade and retrograde flow rotations, standing waves with zero angular velocities can emerge. A striking finding is that, under a transverse magnetic field, a second reversal in the flow pattern direction can occur, where the flow pattern evolves into pro-grade rotation again from a retrograde state. Flow reversal is relevant to intriguing phenomena in nature such as geomagnetic reversal. Our results suggest that, in ferrofluids, flow pattern reversal can be induced by varying a magnetic field in a controlled manner, which can be realized in laboratory experiments with potential applications in the development of modern fluid devices.

  12. Grade inflation at a north american college of veterinary medicine: 1985-2006.

    PubMed

    Rush, Bonnie R; Elmore, Ronnie G; Sanderson, Michael W

    2009-01-01

    Grade inflation, an upward shift in student grade-point averages without a similar rise in achievement, is considered pervasive by most experts in post-secondary education in the United States. Grade-point averages (GPAs) at US universities have increased by roughly 0.15 points per decade since the 1960s, with a 0.6-point increase since 1967. In medical education, grade inflation has been documented and is particularly evident in the clinical setting. The purpose of this study was to evaluate grade inflation over a 22-year period in a college of veterinary medicine. Academic records from 2,060 students who graduated from the College of Veterinary Medicine at Kansas State University between 1985 and 2006 were evaluated, including cumulative GPAs earned during pre-clinical professional coursework, during clinical rotations, and at graduation. Grade inflation was documented at a rate of approximately 0.2 points per decade at this college of veterinary medicine. The difference in mean final GPA between the minimum (1986) and maximum (2003) years of graduation was 0.47 points. Grade inflation was similar for didactic coursework (years 1-3) and clinical rotations (final year). Demographic shifts, student qualifications, and tuition do not appear to have contributed to grade inflation over time. A change in academic standards and student evaluation of teaching may have contributed to relaxed grading standards, and technology in the classroom may have led to higher (earned) grades as a result of improved student learning.

  13. The Analysis of Adhesively Bonded Advanced Composite Joints Using Joint Finite Elements

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.

    2012-01-01

    The design and sizing of adhesively bonded joints has always been a major bottleneck in the design of composite vehicles. Dense finite element (FE) meshes are required to capture the full behavior of a joint numerically, but these dense meshes are impractical in vehicle-scale models where a course mesh is more desirable to make quick assessments and comparisons of different joint geometries. Analytical models are often helpful in sizing, but difficulties arise in coupling these models with full-vehicle FE models. Therefore, a joint FE was created which can be used within structural FE models to make quick assessments of bonded composite joints. The shape functions of the joint FE were found by solving the governing equations for a structural model for a joint. By analytically determining the shape functions of the joint FE, the complex joint behavior can be captured with very few elements. This joint FE was modified and used to consider adhesives with functionally graded material properties to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. Furthermore, proof-of-concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint. Furthermore, the capability to model non-linear adhesive constitutive behavior with large rotations was developed, and progressive failure of the adhesive was modeled by re-meshing the joint as the adhesive fails. Results predicted using the joint FE was compared with experimental results for various joint configurations, including double cantilever beam and single lap joints.

  14. Modeling and analyzing flow of third grade nanofluid due to rotating stretchable disk with chemical reaction and heat source

    NASA Astrophysics Data System (ADS)

    Hayat, T.; Ahmad, Salman; Khan, M. Ijaz; Alsaedi, A.

    2018-05-01

    This article addresses flow of third grade nanofluid due to stretchable rotating disk. Mass and heat transports are analyzed through thermophoresis and Brownian movement effects. Further the effects of heat generation and chemical reaction are also accounted. The obtained ODE's are tackled computationally by means of homotopy analysis method. Graphical outcomes are analyzed for the effects of different variables. The obtained results show that velocity reduces through Reynolds number and material parameters. Temperature and concentration increase with Brownian motion and these decrease by Reynolds number.

  15. Reverse shoulder arthroplasty for deltoid-deficient shoulder following latissimus dorsi flap transfer. Case report.

    PubMed

    Dosari, Mohamed Al Ateeq Al; Hameed, Shamsi; Mukhtar, Khalid; Elmhiregh, Aissam

    2017-01-01

    The usual indication for reverse shoulder arthroplasty is glenohumeral arthritis with inadequate rotator cuff and intact deltoid muscle. We report here a case of reverse shoulder arthroplasty using a lattisimus dorsi flap in a patient with deltoid-deficient shoulder following a gunshot injury. The patient was an otherwise healthy 51-year-old male with a history of gunshot injury of the left shoulder 2006. Upon presentation in 2011, the patient had a loss of most of his shoulder bony and muscular structures. Due to deltoid muscle deficiency, the patient underwent Lattisimus Dorsi muscle flap followed by reverse shoulder arthroplasty in order to establish an upper limb function. Upon discharge, 11days after the surgery, the patient was able to achieve 150° flexion and 90° abduction while in the supine position and 45° in each direction, while sitting. He was able to perform internal rotation (behind back) up to the level of the L1 vertebra, assisted active abduction of 90°, and external rotation of 20°. Power tests showed power of grade 4/5 for both shoulder flexion and extension and grade 2+/5 for both abduction and adduction. At the last follow up one year after the operation, The patient still had passive pain-free full range of motion, but no progress in active range of motion beyond that upon discharge. Reverse shoulder arthroplasty after Latissmus dori flap in patient with deltoid deficient shoulders can be a successful and reproducible approach to treat such conditions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Magnetic anisotropy at material interfaces

    NASA Astrophysics Data System (ADS)

    Greene, Peter Kevin

    In this dissertation, a comprehensive set of depth dependent magnetic measurements, as well as structural characterizations, were carried out on the Co/Pd multilayer system. The first-order reversal curve (FORC) technique is applied extensively to identify reversal mechanisms and different reversal phases within the material. In particular, the extension of the FORC technique to x-ray magnetic circular dichroism (XMCD) as a surface sensitive technique that identifies reversible magnetization change was performed for the first time. Polarized neutron reflectivity (PNR) was also used to directly measure the magnetization as a function of depth. The effects of deposition pressure grading within the Co/Pd multilayers were investigated. Structures were graded with three distinct pressure regions. FORC analysis shows that not only does increasing the deposition pressure increase the coercivity and effective anisotropy within that region, but also the order in which the pressure is changed also affects the entire structure. Layers grown at high sputtering pressures tend to reverse via domain wall pinning and rotation while those grown at lower pressures reverse via rapid domain wall propagation laterally across the film. Having high pressure layers underneath low pressure layers causes disorder to vertically propagate and lessen the induced anisotropy gradient. This analysis is confirmed by depth dependent magnetization profiles obtain from PNR. Continuously pressure-graded Co/Pd multilayers were then sputtered at two incident angles onto porous aluminum oxide templates with different pore aspect ratios. The effects of pressure grading versus uniform low pressure deposition is studied, as well as the effect of the angle of the incident deposition flux. The coercivity of the pressure graded perpendicular flux sample is compared to the low pressure sample. Additionally the effect of deposition angle and pore sidewall deposition is investigated. It is shown that sidewall deposition strongly affects the reversal behavior. As another way to induce a vertical anisotropy gradient, Co/Pd multilayers were bombarded with Ar+ ions at different energies and fluences. The effects of the depth dependent structural damage as a function of irradiation conditions were investigated. It is shown that the structural damage weakens the perpendicular anisotropy of the surface layers, causing a tilting of the surface magnetic moment into the plane of the film. The surface behavior is explicitly measured and shown to have a significant tilting angle in the top 5 nm depending on irradiation energy and fluence. Continuing the study of vertical anisotropy gradients in Co/Pd multilayers, multilayers with varied Co thickness were studied. Four films with varying Co thickness profiles were created and then patterned into nanodot arrays with diameters between 700 nm and 70 nm. The different films were graded continuously, or in stacks with varying Co thicknesses. An anisotropy gradient is shown to be established in the graded samples, and the switching field is lowered as a result. Furthermore, in the continuously graded samples the magnetization reversal behavior is fundamentally different from all other samples. The thermal energy barriers are measured in the uniform and continuously graded samples, yielding similar results. Finally, the establishment of exchange anisotropy at the ferromagnet / antiferromagnet (FM/AFM) interface in the epitaxial Fe/CoO system is investigated as a function of AFM thickness. The establishment of frozen AFM moments is analyzed using the FORC technique. The FORC technique combined with vector coil measurements also shows the transition from rotatable AFM to pinned AFM moments and suggests a mechanism of winding domain walls within the bulk AFM. (Abstract shortened by UMI.).

  17. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    ERIC Educational Resources Information Center

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  18. Factors associated with clinical and structural outcomes after arthroscopic rotator cuff repair with a suture bridge technique in medium, large, and massive tears.

    PubMed

    Choi, Sungwook; Kim, Myung Ku; Kim, Gyeong Min; Roh, Young-Ho; Hwang, Im Kyung; Kang, Hyunseong

    2014-11-01

    This study was conducted to evaluate clinical outcomes, maintenance of repair integrity, and retear rate after arthroscopic rotator cuff repair by a suture bridge technique among patients with medium, large, and massive rotator cuff tears. We evaluated 147 patients who had undergone arthroscopic rotator cuff repair. Clinical and functional evaluations were performed with the Constant and University of California-Los Angeles scores. All patients were confirmed to have magnetic resonance imaging evidence of tendon healing at least 12 months postoperatively. The average postoperative time to follow-up magnetic resonance imaging was 23.4 months (range, 12-48 months). A total of 25 (17.0%) retears were observed. All clinical outcome scores were improved significantly at follow-up. Larger intraoperative tear sizes were correlated with higher retear rates. The incidence of retear was also higher in cases in which the preoperative fatty degeneration grade was higher. The incidence of retear increased with age and in the heavy worker group (e.g., farmers, carriers, car mechanics) but was not statistically significant. Arthroscopic rotator cuff repair by a suture bridge technique yields improvements in clinical outcome measures and a relatively high degree of patient satisfaction despite the fact that repair integrity is not maintained in many cases. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. The development of confocal arthroscopy as optical histology for rotator cuff tendinopathy.

    PubMed

    Wu, J-P; Walton, M; Wang, A; Anderson, P; Wang, T; Kirk, T B; Zheng, M H

    2015-09-01

    MRI, ultrasound and video arthroscopy are traditional imaging technologies for noninvasive or minimal invasive assessment of the rotator cuff tendon pathology. However, these imaging modalities do not have sufficient resolution to demonstrate the pathology of rotator cuff tendons at a microstructural level. Therefore, they are insensitive to low-level tendon diseases. Although traditional histology can be used to analyze the physiology of rotator cuff tendons, it requires biopsy that traumatizes the rotator cuff, thus, potentially comprising the mechanical properties of tendons. Besides, it cannot offer real-time histological information. Confocal endoscopy offers a way to assess the microstructural disorder in tissues without biopsy. However, the application of this useful technique for detecting low-level tendon diseases has been restricted by using clinical grade fluorescent contrast agent to acquire high-resolution microstructural images of tendons. In this study, using a clinical grade sodium fluorescein contrast agent, we have reported the development of confocal arthroscopy for optical histological assessment without biopsy. The confocal arthroscopic technique was able to demonstrate rotator cuff tendinopathy in human cadavers, which appeared macroscopically normal under video arthroscopic examinations. The tendinopathy status of the rotator cuff tendons was confirmed by corresponding traditional histology. The development of confocal arthroscopy may provide a minimally invasive imaging technique for real-time histology of rotator cuff without the need for tissue biopsy. This technique has the potential for surgeons to gain in real time the histological information of rotator cuff tendons, which may assist planning repair strategies and potentially improve intervention outcomes. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  20. Satisfactory knee function after single-stage posterolateral corner reconstruction in the multi-ligament injured/dislocated knee using the anatomic single-graft technique.

    PubMed

    Sanders, Thomas L; Johnson, Nick R; Pareek, Ayoosh; Krych, Aaron J; Marx, Robert G; Stuart, Michael J; Levy, Bruce A

    2018-04-01

    Increasing importance has been placed on the posterolateral corner (PLC) in maintaining varus and rotational stability of the knee. The goal of this study was to evaluate knee function and clinical stability following a single-graft PLC reconstruction technique and identify factors associated with poor knee function. This study identified patients with a multi-ligament knee injury between 2006 and 2013. Patients who received a single-graft fibular collateral ligament and PLC reconstruction with a single-stage surgery during the study period and had a minimum follow-up of 2 years after surgery were included. Functional outcomes were assessed using Lysholm and IKDC scores. Varus and rotational knee laxity and range of motion were assessed using physical examination. The final study cohort included 61 patients who underwent PLC reconstruction using a single-graft technique. The mean IKDC score was 74.1 (± 22.3) and the mean Lysholm score was 80.3 (± 21.8) at mean follow-up of 3.8 years (range 2-9 years). Mean range of motion at final follow-up measured from 0° to 126° [range flexion: 95-145, range extension: 0-5]. Fifty-eight patients (95%) had grade 0 varus laxity in full knee extension, and 54 patients (88.5%) had grade 0 varus laxity at 30° of knee flexion. Female gender was associated with a lower postoperative IKDC score (p = 0.04). Surgical treatment of the PLC using a single-graft technique can result in satisfactory knee function and stable physical examination findings at minimum 2 years after surgery. Female gender was predictive of poor knee function after PLC reconstruction. Surgical treatment of PLC injuries should be individualized based on the timing of surgery, specific injured knee structures, and physical examination findings. This study helps validate the use of a single-graft technique for PLC reconstruction and can be used to help counsel patients about expected knee function after surgical treatment of PLC injuries. Level of evidence IV.

  1. Determinants of image quality of rotational angiography for on-line assessment of frame geometry after transcatheter aortic valve implantation.

    PubMed

    Rodríguez-Olivares, Ramón; El Faquir, Nahid; Rahhab, Zouhair; Maugenest, Anne-Marie; Van Mieghem, Nicolas M; Schultz, Carl; Lauritsch, Guenter; de Jaegere, Peter P T

    2016-07-01

    To study the determinants of image quality of rotational angiography using dedicated research prototype software for motion compensation without rapid ventricular pacing after the implantation of four commercially available catheter-based valves. Prospective observational study including 179 consecutive patients who underwent transcatheter aortic valve implantation (TAVI) with either the Medtronic CoreValve (MCS), Edward-SAPIEN Valve (ESV), Boston Sadra Lotus (BSL) or Saint-Jude Portico Valve (SJP) in whom rotational angiography (R-angio) with motion compensation 3D image reconstruction was performed. Image quality was evaluated from grade 1 (excellent image quality) to grade 5 (strongly degraded). Distinction was made between good (grades 1, 2) and poor image quality (grades 3-5). Clinical (gender, body mass index, Agatston score, heart rate and rhythm, artifacts), procedural (valve type) and technical variables (isocentricity) were related with the image quality assessment. Image quality was good in 128 (72 %) and poor in 51 (28 %) patients. By univariable analysis only valve type (BSL) and the presence of an artefact negatively affected image quality. By multivariate analysis (in which BMI was forced into the model) BSL valve (Odds 3.5, 95 % CI [1.3-9.6], p = 0.02), presence of an artifact (Odds 2.5, 95 % CI [1.2-5.4], p = 0.02) and BMI (Odds 1.1, 95 % CI [1.0-1.2], p = 0.04) were independent predictors of poor image quality. Rotational angiography with motion compensation 3D image reconstruction using a dedicated research prototype software offers good image quality for the evaluation of frame geometry after TAVI in the majority of patients. Valve type, presence of artifacts and higher BMI negatively affect image quality.

  2. Tensile strength/yield strength (TS/YS) ratios of high-strength steel (HSS) reinforcing bars

    NASA Astrophysics Data System (ADS)

    Tavio, Anggraini, Retno; Raka, I. Gede Putu; Agustiar

    2018-05-01

    The building codes such as American Concrete Institute (ACI) 318M-14 and Standard National Indonesia (SNI) 2847:2013 require that the ratio of tensile strength (TS) and yield strength (YS) should not less than 1.25. The requirement is based on the assumption that a capability of a structural member to develop inelastic rotation capacity is a function of the length of the yield region. This paper reports an investigation on various steel grades, namely Grades 420, 550, 650, and 700 MPa, to examine the impact of different TS/YS ratios if it is less or greater than the required value. Grades 550, 650, and 700 MPa were purposely selected with the intention to examine if these higher grades are still promising to be implemented in special structural systems since they are prohibited by the building codes for longitudinal reinforcement, whereas Grade 420 MPa bars are the maximum limit of yield strength of reinforcing bars that is allowable for longitudinal reinforcement of special structural systems. Tensile tests of these steel samples were conducted under displacement controlled mode to capture the complete stress-strain curves and particularly the post-yield response of the steel bars. From the study, it can be concluded that Grade 420 performed higher TS/YS ratios and they were able to reach up to more than 1.25. However, the High Strength Still (HSS) bars (Grades 550, 600, and 700 MPa) resulted in lower TS/YS ratios (less than 1.25) compared with those of Grade 420 MPa.

  3. Processing and Characterization of Functionally Graded Aluminum (A319)—SiCp Metallic Composites by Centrifugal Casting Technique

    NASA Astrophysics Data System (ADS)

    Jayakumar, E.; Jacob, Jibin C.; Rajan, T. P. D.; Joseph, M. A.; Pai, B. C.

    2016-08-01

    Functionally graded materials (FGM) are successfully adopted for the design and fabrication of engineering components with location-specific properties. The present study describes the processing and characterization of A319 Aluminum functionally graded metal matrix composites (FGMMC) with 10 and 15 wt pct SiCp reinforcements. The liquid stir casting method is used for composite melt preparation followed by FGMMC formation by vertical centrifugal casting method. The process parameters used are the mold preheating temperature of 523 K (250 °C), melt pouring temperature of 1013 K (740 °C), and mold rotation speed of 1300 rpm. The study analyzes the distribution and concentration of reinforcement particles in the radial direction of the FGMMC disk along with the effects of gradation on density, hardness, mechanical strength, the variation in coefficient of thermal expansion and the wear resistance properties at different zones. Microstructures of FGMMC reveal an outward radial gradient distribution of reinforcements forming different zones. Namely, matrix-rich inner, transition, particles-rich outer, and chill zone of a few millimeters thick at the outer most periphery of the casting are formed. From 10-FGM, a radial shift in the position of SiCp maxima is observed in 15-FGM casting. The mechanical characterization depicts enhanced properties for the particle-rich zone. The hardness shows a graded nature in correlation with particle concentration and a maximum of 94.4 HRB has been obtained at the particle-rich region of 15-FGM. In the particle-rich zone, the lowest CTE value of 20.1 µm/mK is also observed with a compressive strength of 650 MPa and an ultimate tensile strength of 279 MPa. The wear resistance is higher at the particle-rich zone of the FGMMC.

  4. Optimal Pelvic Incidence Minus Lumbar Lordosis Mismatch after Long Posterior Instrumentation and Fusion for Adult Degenerative Scoliosis.

    PubMed

    Zhang, Hao-Cong; Zhang, Zi-Fang; Wang, Zhao-Han; Cheng, Jun-Yao; Wu, Yun-Chang; Fan, Yi-Ming; Wang, Tian-Hao; Wang, Zheng

    2017-08-01

    To evaluate the influence of Scoliosis Research Society (SRS)-Schwab sagittal modifiers of pelvic incidence minus lumbar lordosis mismatch (PI-LL) on clinical outcomes for adult degenerative scoliosis (ADS) after long posterior instrumentation and fusion. This was a single-institute, retrospective study. From 2012 to 2014, 44 patients with ADS who underwent posterior instrumentation and fusion treatment were reviewed. Radiological evaluations were investigated by standing whole spine (posteroanterior and lateral views) X-ray and all radiological measurements, including Cobb's angle, LL, PI, and the grading of vertebral rotation, were performed by two experienced surgeons who were blind to the operations. The patients were divided into three groups based on postoperative PI-LL and the classification of the SRS-Schwab: 0 grade PI-LL (<10°, n = 13); + grade PI-LL (10°-20°, n = 19); and ++ grade PI-LL (>20°, n = 12). The clinical outcomes were assessed according to Japanese Orthopaedic Association (JOA) score, Oswestry Disability Index (ODI), Visual Analog Scale (VAS), Lumbar Stiffness Disability Index (LSDI), and complications. Other characteristic data of patients were also collected, including intraoperative blood loss, operative time, length of hospital stay, complications, number of fusion levels, and number of decompressions. The mean operative time, blood loss, and hospital stay were 284.5 ± 30.2 min, 1040.5 ± 1207.6 mL, and 14.5 ± 1.9 day. At the last follow-up (2.6 ± 0.6 years), the radiological and functional parameters, except the grading of vertebral rotation, were all significantly improved in comparison with preoperative results (P < 0.05), but it was obvious that an ideal PI-LL (≤10°) was not achieved in some patients. Significant differences were only observed among the three groups in the ODI and LSDI. Patients with + grade PI-LL seemed to have the best surgical outcome compared to those with 0 and ++ grade PI-LL, with the lowest ODI score (+ grade vs 0 grade, 17.3 ± 4.9 vs 26.0 ± 5.4; + grade vs ++ grade, 17.3 ± 4.9 vs 32.4 ± 7.3; P < 0.05) and lower LSDI (+ grade vs 0 grade, 1.6 ± 1.0 vs 3.5 ± 0.5, P < 0.05; + grade vs ++ grade, 1.6 ± 1.0 vs 0.6 ± 0.5, P > 0.05). A Pearson correlation analysis further demonstrated that LSDI was negatively associated with PI-LL. Furthermore, the incidence rate of postoperative complications was lower in patients with + grade PI-LL (1/19, 5.26%) than that in patients with 0 (2/13, 15.4%) and ++ grade PI-LL (3/12, 25%). Our present study suggest that the ideal PI-LL may be between 10° and 20° in ADS patients after long posterior instrumentation and fusion. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  5. Influence of Non-linear Radiation Heat Flux on Rotating Maxwell Fluid over a Deformable Surface: A Numerical Study

    NASA Astrophysics Data System (ADS)

    Mustafa, M.; Mushtaq, A.; Hayat, T.; Alsaedi, A.

    2018-04-01

    Mathematical model for Maxwell fluid flow in rotating frame induced by an isothermal stretching wall is explored numerically. Scale analysis based boundary layer approximations are applied to simplify the conservation relations which are later converted to similar forms via appropriate substitutions. A numerical approach is utilized to derive similarity solutions for broad range of Deborah number. The results predict that velocity distributions are inversely proportional to the stress relaxation time. This outcome is different from that observed for the elastic parameter of second grade fluid. Unlike non-rotating frame, the solution curves are oscillatory decaying functions of similarity variable. As angular velocity enlarges, temperature rises and significant drop in the heat transfer coefficient occurs. We note that the wall slope of temperature has an asymptotically decaying profile against the wall to ambient ratio parameter. From the qualitative view point, temperature ratio parameter and radiation parameter have similar effect on the thermal boundary layer. Furthermore, radiation parameter has a definite role in improving the cooling process of the stretching boundary. A comparative study of current numerical computations and those from the existing studies is also presented in a limiting case. To our knowledge, the phenomenon of non-linear radiation in rotating viscoelastic flow due to linearly stretched plate is just modeled here.

  6. Subacromial injection of autologous platelet-rich plasma versus corticosteroid for the treatment of symptomatic partial rotator cuff tears.

    PubMed

    Shams, Ahmed; El-Sayed, Mohamed; Gamal, Osama; Ewes, Waled

    2016-12-01

    Rotator cuff tears are one of the most common causes of chronic shoulder pain and disability. They significantly affect the quality of life. Reduced pain and improved function are the goals of conventional therapy, which includes relative rest, pain therapy, physical therapy, corticosteroid injections and surgical intervention. Tendons have a relative avascular nature; hence, their regenerative potential is limited. There is some clinical evidence that the application of autologous platelets may help to revascularize the area of injury in rotator cuff pathologies. This prospective randomized controlled study was done to evaluate the results of subacromial injection of platelet-rich plasma (PRP) versus corticosteroid injection therapy in 40 patients with symptomatic partial rotator cuff tears. All patients were assessed before injection, 6 weeks, 3 and 6 months after injection, using the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), the Constant-Murley Score (CMS), the Simple Shoulder Test (SST) and a Visual Analog Scale (VAS) for pain. An MRI was performed before and 6 months after the injection for all the included patients and was graded on 0-5 scale. Both injection groups showed statistically significantly better clinical outcomes over time compared with those before injection. There was a statistically significant difference between RPP group and corticosteroid group 12 weeks after injection, regarding VAS, ASES, CMS and SST in favor of the RPP group. MRI showed an overall slight nonsignificant improvement in grades of tendinopathy/tear in both groups, however, without statistically significant differences between the two groups. PRP injections showed earlier better results as compared to corticosteroid injections, although statistically significant better results after 6 months could not be found. Therefore, subacromial RPP injection could be considered as a good alternative to corticosteroid injection, especially in patients with a contraindication to corticosteroid administration. II.

  7. Kinetics of throwing arm joints and the trunk motion during an overarm distance throw by skilled Japanese elementary school boys.

    PubMed

    Kobayashi, Yasuto; Ae, Michiyoshi; Miyazaki, Akiyo; Fujii, Norihisa; Iiboshi, Akira; Nakatani, Hideki

    2016-09-01

    The purpose of this study was to investigate joint kinetics of the throwing arms and role of trunk motion in skilled elementary school boys during an overarm distance throw. Throwing motions of 42 boys from second, fourth, and sixth grade were videotaped with three high-speed cameras operating at 300 fps. Seven skilled boys from each grade were selected on the basis of throwing distance for three-dimensional kinetic analysis. Joint forces, torques, and torque powers of the throwing arm joints were calculated from reconstructed three-dimensional coordinate data smoothed at cut-off frequencies of 10.5-15 Hz and by the inverse dynamics method. Throwing distance and ball velocity significantly increased with school grade. The angular velocity of elbow extension before ball release increased with school grade, although no significant increase between the grades was observed in peak extension torque of elbow joint. The joint torque power of shoulder internal/external rotation tended to increase with school grade. When teaching the overarm throw, elementary school teachers should observe large backward twisting of trunk during the striding phase and should keep in mind that young children, such as second graders (age 8 years), will be unable to effectively utilise shoulder external/internal rotation during the throwing phase.

  8. The Association Between Rotator Cuff Muscle Fatty Infiltration and Glenoid Morphology in Glenohumeral Osteoarthritis.

    PubMed

    Donohue, Kenneth W; Ricchetti, Eric T; Ho, Jason C; Iannotti, Joseph P

    2018-03-07

    Glenoid morphology and rotator cuff muscle quality are important anatomic factors that can impact longevity of the glenoid component following total shoulder arthroplasty (TSA). We hypothesized that rotator cuff muscle fatty infiltration is associated with increased pathologic glenoid bone loss in glenohumeral osteoarthritis (OA). We retrospectively reviewed 190 preoperative computed tomography (CT) scans of 175 patients (mean age, 66 years; range, 44 to 90 years) who underwent TSA for the treatment of primary glenohumeral OA. Two-dimensional orthogonal CT images were reformatted in the plane of the scapula from 3-dimensional images. Pathologic joint-line medialization was defined with use of the glenoid vault model. Pathologic glenoid version was measured directly. Glenoid morphology was graded according to a modified Walch classification (subtypes A1, A2, B1, B2, B3, C1, and C2). Rotator cuff muscle fatty infiltration was assessed and assigned a Goutallier score on the sagittal CT slice just medial to the spinoglenoid notch for each muscle. There was a significant difference in the Goutallier score for the supraspinatus, infraspinatus, and teres minor muscles between Walch subtypes (p ≤ 0.05). High-grade posterior rotator cuff muscle fatty infiltration was present in 55% (21) of 38 B3 glenoids compared with 8% (3) of 39 A1 glenoids. Increasing joint-line medialization was associated with increasing fatty infiltration of all rotator cuff muscles (p ≤ 0.05). Higher fatty infiltration of the infraspinatus, teres minor, and combined posterior rotator cuff muscles was associated with increasing glenoid retroversion (p ≤ 0.05). After controlling for joint-line medialization and retroversion, B3 glenoids were more likely to have fatty infiltration of the supraspinatus and infraspinatus muscles than B2 glenoids were. High-grade rotator cuff muscle fatty infiltration is associated with B3 glenoids, increased pathologic glenoid retroversion, and increased joint-line medialization. Additional studies are needed to determine the causal relationship between these muscle changes and glenoid wear, whether these muscle changes independently affect clinical and radiographic outcomes in anatomic TSA, and whether fatty infiltration can improve postoperatively with correction of pathologic version and/or joint-line restoration. This study investigates the association between different patterns of glenoid bone loss and rotator cuff muscle fatty infiltration. Both factors have been shown to affect clinical outcome following TSA.

  9. Pseudoparalysis From a Massive Rotator Cuff Tear Is Reliably Reversed With an Arthroscopic Rotator Cuff Repair in Patients Without Preoperative Glenohumeral Arthritis.

    PubMed

    Denard, Patrick J; Lädermann, Alexandre; Brady, Paul C; Narbona, Pablo; Adams, Christopher R; Arrigoni, Paolo; Huberty, Dave; Zlatkin, Michael B; Sanders, Timothy G; Burkhart, Stephen S

    2015-10-01

    Pseudoparalysis is defined as active forward flexion less than 90° with full passive motion. There is controversy about the ideal surgical management of a massive rotator cuff tear with pseudoparalysis. The purpose of this study was to prospectively analyze the ability to reverse pseudoparalysis with an arthroscopic rotator cuff repair (ARCR). The hypothesis was that in the absence of substantial glenohumeral arthritis, preoperative fatty infiltration of grade 3 or higher and an acromiohumeral interval (AHI) of less than 7 mm would not prevent reversal of pseudoparalysis with an ARCR. Case series; Level of evidence, 4. A prospective multicenter study of ARCR performed for preoperative pseudoparalysis was conducted. The minimum follow-up was 1 year. The mean patient age was 63 years, and pseudoparalysis was present for a mean of 4.2 months preoperatively. Preoperative radiographic evaluation included plain film evaluation of the AHI and Hamada classification and MRI evaluation of fatty degeneration and rotator cuff retraction. Functional outcome was determined by the Simple Shoulder Test (SST), American Shoulder and Elbow Surgeons (ASES) Shoulder Score, visual analog scale (VAS), and subjective shoulder value (SSV). Of the 58 patients enrolled, 56 had at least 1 year of follow-up. Mean active forward flexion improved from 47° preoperatively to 159° postoperatively (P < .001). Statistically significant improvements were seen in the SST (from 2.8 preoperatively to 10.1 postoperatively), SSV (from 28 to 83), ASES Shoulder Score (from 37 to 88), and VAS (from 5.7 to 1.1) (P < .001). Pseudoparalysis was reversed in 53 of 56 patients (95%). There was no difference in the rate of reversal of pseudoparalysis between those patients with an AHI of less than 7 mm (88.2%) and those with an AHI of 7 mm or more (96.9%) (P =.289). Pseudoparalysis was reversed in all 8 of the patients with fatty degeneration of grade 3 or higher in 1 or more of the rotator cuff muscles. ARCR can lead to reversal of preoperative pseudoparalysis in patients with minimal preoperative glenohumeral arthritis. ARCR is a viable first line of treatment for patients with pseudoparalysis in the absence of advanced glenohumeral arthritis. © 2015 The Author(s).

  10. Spatial transformation abilities and their relation to later mathematics performance.

    PubMed

    Frick, Andrea

    2018-04-10

    Using a longitudinal approach, this study investigated the relational structure of different spatial transformation skills at kindergarten age, and how these spatial skills relate to children's later mathematics performance. Children were tested at three time points, in kindergarten, first grade, and second grade (N = 119). Exploratory factor analyses revealed two subcomponents of spatial transformation skills: one representing egocentric transformations (mental rotation and spatial scaling), and one representing allocentric transformations (e.g., cross-sectioning, perspective taking). Structural equation modeling suggested that egocentric transformation skills showed their strongest relation to the part of the mathematics test tapping arithmetic operations, whereas allocentric transformations were strongly related to Numeric-Logical and Spatial Functions as well as geometry. The present findings point to a tight connection between early mental transformation skills, particularly the ones requiring a high level of spatial flexibility and a strong sense for spatial magnitudes, and children's mathematics performance at the beginning of their school career.

  11. Fatty degeneration of the rotator cuff muscles on pre- and postoperative CT arthrography (CTA): is the Goutallier grading system reliable?

    PubMed

    Lee, Eugene; Choi, Jung-Ah; Oh, Joo Han; Ahn, Soyeon; Hong, Sung Hwan; Chai, Jee Won; Kang, Heung Sik

    2013-09-01

    To retrospectively evaluate fatty degeneration (FD) of rotator cuff muscles on CTA using Goutallier's grading system and quantitative measurements with comparison between pre- and postoperative states. IRB approval was obtained for this study. Two radiologists independently reviewed pre- and postoperative CTAs of 43 patients (24 males and 19 females, mean age, 58.1 years) with 46 shoulders confirmed as full-thickness tears with random distribution. FD of supraspinatus, infraspinatus/teres minor, and subscapularis was assessed using Goutallier's system and by quantitative measurements of Hounsfield units (HUs) on sagittal images. Changes in FD grades and HUs were compared between pre- and postoperative CTAs and analyzed with respect to preoperative tear size and postoperative cuff integrity. The correlations between qualitative grades and quantitative measurements and their inter-observer reliabilities were also assessed. There was statistically significant correlation between FD grades and HU measurements of all muscles on pre- and postoperative CTA (p < 0.05). Inter-observer reliability of fatty degeneration grades were excellent to substantial on both pre- and postoperative CTA in supraspinatus (0.8685 and 0.8535) and subscapularis muscles (0.7777 and 0.7972), but fair in infraspinatus/teres minor muscles (0.5791 and 0.5740); however, quantitative Hounsfield units measurements showed excellent reliability for all muscles (ICC: 0.7950 and 0.9346 for SST, 0.7922 and 0.8492 for SSC, and 0.9254 and 0.9052 for IST/TM). No muscle showed improvement of fatty degeneration after surgical repair on qualitative and quantitative assessments; there was no difference in changes of fatty degeneration after surgical repair according to preoperative tear size and post-operative cuff integrity (p > 0.05). The average dose-length product (DLP, mGy · cm) was 365.2 mGy · cm (range, 323.8-417.2 mGy · cm) and estimated average effective dose was 5.1 mSv. Goutallier grades correlated well with HUs of rotator cuff muscles. Reliability was excellent for both systems, except for FD grade of IST/TM muscles, which may be more reliably assessed using quantitative measurements.

  12. Factors Predictive of Healing in Large Rotator Cuff Tears: Is It Possible to Predict Retear Preoperatively?

    PubMed

    Jeong, Ho Yeon; Kim, Hwan Jin; Jeon, Yoon Sang; Rhee, Yong Girl

    2018-03-01

    Many studies have identified risk factors that cause retear after rotator cuff repair. However, it is still questionable whether retears can be predicted preoperatively. To determine the risk factors related to retear after arthroscopic rotator cuff repair and to evaluate whether it is possible to predict the occurrence of retear preoperatively. Case-control study; Level of evidence, 3. This study enrolled 112 patients who underwent arthroscopic rotator cuff repair with single-row technique for a large-sized tear, defined as a tear with a mediolateral length of 3 to 5 cm. All patients underwent routine magnetic resonance imaging (MRI) at 9 months postoperatively to assess tendon integrity. The sample included 61 patients (54.5%) in the healed group and 51 (45.5%) in the retear group. In multivariate analysis, the independent predictors of retears were supraspinatus muscle atrophy ( P < .001) and fatty infiltration of the infraspinatus ( P = .027), which could be preoperatively measured by MRI. A significant difference was found between the two groups in sex, the acromiohumeral interval, tendon tension, and preoperative or intraoperative mediolateral tear length and musculotendinous junction position in univariate analysis. However, these variables were not independent predictors in multivariate analysis. The cutoff values of occupation ratio of supraspinatus and fatty infiltration of the infraspinatus were 43% and grade 2, respectively. The occupation ratio of supraspinatus <43% and grade ≥2 fatty infiltration of the infraspinatus were the strongest predictors of retear, with an area under the curve of 0.908, sensitivity of 98.0%, and specificity of 83.6% (accuracy = 90.2%). In patients with large rotator cuff tears, it was possible to predict the retear before rotator cuff repair regardless of intraoperative factors. The retear could be predicted most effectively when the occupation ratio of supraspinatus was <43% or the fatty infiltration of infraspinatus was grade ≥2. Predicting retear preoperatively may help surgeons determine proper treatment and predict the postoperative prognosis.

  13. Evaluation of tillage, cover crop, & herbicide effects on weed control, yield and grade in peanut?

    USDA-ARS?s Scientific Manuscript database

    Peanut production continues to play a large role in agriculture in the Southeastern United States and weed challenges persist. Therefore, it is important to reduce weed competition in peanut to protect yield and grade. With traditional use of herbicides for weed control in peanut and rotational crop...

  14. Functional and oncological outcome after surgical resection of the scapula and clavicle for primary chondrosarcoma.

    PubMed

    Nota, S P F T; Russchen, M J A M; Raskin, K A; Mankin, H J; Hornicek, F J; Schwab, J H

    2017-04-01

    The scapula is a relatively common site for chondrosarcoma to develop in contrary to the clavicle, which is rarely affected by these tumors. The aim of this study is to determine the functional and oncological outcome for patients treated operatively for scapular or clavicular chondrosarcoma. In this single-center retrospective study, we included a sample of 20 patients that received the diagnosis of a primary chondrosarcoma of the scapula or clavicle. Of the surviving patients, the functional function was assessed using the DASH and the PROMIS Physical Function-Upper Extremity. Patients were longitudinally tracked for their oncological outcome. All patients were followed for at least 2 years or until death. The mean age of the cohort was 47 years. Eighteen patients suffered from a chondrosarcoma of the scapula, and in 2 patients, the tumor was located in the clavicle. Metastasis, local recurrence and a higher tumor grade were all associated with a decreased overall survival. For the patients with a chondrosarcoma of the scapula, the average DASH score was 16 ± 16 and the mean PROMIS Physical Function-Upper Extremity score was 48 ± 10. Patients with both an intact rotator cuff and glenoid had a better physical function. Upper extremity function after (partial) scapulectomy varied depending on whether the glenoid was spared and whether a functioning shoulder abductor remained. When the resection spared these structures, then excellent functional outcomes were reported. Oncologic outcomes depended upon the grade of the tumor and whether local recurrence and metastases occurred.

  15. Asymptomatic Elite Adolescent Tennis Players' Signs of Tendinosis in Their Dominant Shoulder Compared With Their Nondominant Shoulder

    PubMed Central

    Johansson, Fredrik R.; Skillgate, Eva; Adolfsson, Anders; Jenner, Göran; DeBri, Edin; Swärdh, Leif; Cools, Ann M.

    2015-01-01

    Context Tennis is an asymmetric overhead sport with specific muscle-activation patterns, especially eccentrically in the rotator cuff. Magnetic resonance imaging (MRI) findings in asymptomatic adolescent elite tennis players have not previously been reported. Objective The first aim of the study was to describe MRI findings regarding adaptations or abnormalities, as well as muscle cross-sectional area (CSA), of the rotator cuff. The second aim of the study was to investigate the rotator cuff based on the interpretation of the MRI scans as normal versus abnormal, with the subdivision based on the grade of tendinosis, and its association with eccentric rotator cuff strength in the dominant arm (DA) of the asymptomatic elite adolescent tennis player. Setting Testing environment at the radiology department of Medicinsk Röntgen AB. Patients or Other Participants Thirty-five asymptomatic elite tennis players (age = 17.4 ± 2.7 years) were selected based on ranking and exposure time. Intervention(s) We assessed MRI scans and measured the CSA of the rotator cuff muscle. The non-DA (NDA) was used as a control. In addition, eccentric testing of the external rotators of the DA was performed with a handheld dynamometer. Results The DA and NDA displayed different frequencies of infraspinatus tendinosis (grade 1 changes) (P < .05). Rotator cuff measurements revealed larger infraspinatus and teres minor CSA (P < .05) in the DA than in the NDA. Mean eccentric external-rotation strength in the DA stratified by normal tendon and tendinosis was not different between groups (P = .723). Conclusions Asymptomatic adolescent elite tennis players demonstrated infraspinatus tendinosis more frequently in the DA than in the NDA. Clinicians must recognize these tendon changes in order to modify conditioning and performance programs appropriately. PMID:26651279

  16. Functional model of biological neural networks.

    PubMed

    Lo, James Ting-Ho

    2010-12-01

    A functional model of biological neural networks, called temporal hierarchical probabilistic associative memory (THPAM), is proposed in this paper. THPAM comprises functional models of dendritic trees for encoding inputs to neurons, a first type of neuron for generating spike trains, a second type of neuron for generating graded signals to modulate neurons of the first type, supervised and unsupervised Hebbian learning mechanisms for easy learning and retrieving, an arrangement of dendritic trees for maximizing generalization, hardwiring for rotation-translation-scaling invariance, and feedback connections with different delay durations for neurons to make full use of present and past informations generated by neurons in the same and higher layers. These functional models and their processing operations have many functions of biological neural networks that have not been achieved by other models in the open literature and provide logically coherent answers to many long-standing neuroscientific questions. However, biological justifications of these functional models and their processing operations are required for THPAM to qualify as a macroscopic model (or low-order approximate) of biological neural networks.

  17. Half forehead reconstruction with a single rotational scalp flap for dermatofibrosarcoma protuberans treatment.

    PubMed

    Mori, Stefano; Di Monta, Gianluca; Marone, Ugo; Chiofalo, Maria Grazia; Caracò, Corrado

    2012-05-06

    Dermatofibrosarcoma protuberans (DFSP) is a soft tissue neoplasm of intermediate to low-grade malignancy. Although metastasis rarely occurs, DFSP has a locally aggressive behavior with a high recurrence rate. In the head and neck area, resection involving a wide margin of healthy tissue can be difficult because of functional and cosmetic considerations. We describe a novel reconstructive method for half forehead defects with an innovative single local wide scalp flap following excision of DFSP with a 3 cm margin of healthy tissue. Two patients underwent wide resection of forehead DFSP and reconstruction with a single rotational scalp flap. The scalp flap blood supply was provided from three main vessels: the superficial temporal artery, occipital artery and posterior auricular artery. No early or late complications were observed in either patient with no local recurrence after 18 months of follow-up. The donor area could be closed primarily in both cases and the flaps survived completely. This innovative technique allowed a radical excision of forehead DFSP with sufficient healthy margins, thus potentially decreasing tumor recurrence rate. Reconstruction was achieved avoiding microsurgery, skin expanders and large skin grafts. Moreover, all main reconstructive criteria, such as functional and cosmetic tissue characteristics, were completely fulfilled.

  18. Magnetic resonance imaging classification of haemodialysis-related amyloidosis of the shoulder: risk factors and arthroscopic treatment.

    PubMed

    Ando, Akira; Hagiwara, Yoshihiro; Sekiguchi, Takuya; Koide, Masashi; Kanazawa, Kenji; Watanabe, Takashi; Itoi, Eiji

    2017-07-01

    This study proposed new magnetic resonance imaging (MRI) of haemodialysis shoulders (HDS) focusing on the changes of the rotator cuff, and rotator interval and risk factors for the development of HDS were examined. Eighty-five shoulders in 72 patients with a chief complaint of shoulder pain during haemodialysis and at least 10 years of haemodialysis were included. They were classified into 5 groups based on the thickness of the rotator cuff and conditions of rotator interval. Clinical and radiological findings in each grade were examined, and risk factors for the development of HDS were evaluated. Arthroscopic surgeries were performed on 22 shoulders in 20 patients, and arthroscopic findings were also evaluated. Positive correlations for the development of HDS were observed in duration of haemodialysis, positive hepatitis C virus (HCV) infection, and previous haemodialysis-related orthopaedic surgery (P < 0.001, respectively). Strong correlations were observed between positive HCV and the progression of HDS (odds ratio 24.8, 95 % confidence interval 5.7-107.6). Arthroscopically, progression of the surrounding soft tissue degeneration was observed, and operative times were lengthened depending on the progression of MRI grading. A new MRI classification of HDS which may be helpful when considering arthroscopic surgeries has been proposed. Positive HCV infection was strongly associated with the progression of HDS on MRI. Conditions of the rotator interval and the rotator cuff based on the MRI classification should be examined when treating HDS patients. III.

  19. Latissimus Dorsi and Teres Major Transfer With Reverse Shoulder Arthroplasty Restores Active Motion and Reduces Pain for Posterosuperior Cuff Dysfunction.

    PubMed

    Shi, Lewis L; Cahill, Kirk E; Ek, Eugene T; Tompson, Jeffrey D; Higgins, Laurence D; Warner, Jon J P

    2015-10-01

    In patients with rotator cuff dysfunction, reverse shoulder arthroplasty can restore active forward flexion, but it does not provide a solution for the lack of active external rotation because of infraspinatus and the teres minor dysfunction. A modified L'Episcopo procedure can be performed in the same setting wherein the latissimus dorsi and teres major tendons are transferred to the lateral aspect of proximal humerus in an attempt to restore active external rotation. (1) Do latissimus dorsi and teres major tendon transfers with reverse shoulder arthroplasty improve external rotation function in patients with posterosuperior rotator cuff dysfunction? (2) Do patients experience less pain and have improved outcome scores after surgery? (3) What are the complications associated with reverse shoulder arthroplasty with latissimus dorsi and teres major transfer? Between 2007 and 2010, we treated all patients undergoing shoulder arthroplasty who had a profound external rotation lag sign and advanced fatty degeneration of the posterosuperior rotator cuff (infraspinatus plus teres minor) with this approach. A total of 21 patients (mean age 66 years; range, 58-82 years) were treated this way and followed for a minimum of 2 years (range, 26-81 months); none was lost to followup, and all have been seen in the last 5 years. We compared pre- and postoperative ranges of motion, pain, and functional status; scores were drawn from chart review. We also categorized major and minor complications. Active forward flexion improved from 56° ± 36° to 120° ± 38° (mean difference: 64° [95% confidence interval {CI}, 45°-83°], p < 0.001). Active external rotation with the arm adducted improved from 6° ± 16° to 38° ± 14° (mean difference: 30° [95% CI, 21°-39°], p < 0.001); active external rotation with the arm abducted improved from 19° ± 25° to 74° ± 22° (mean difference: 44° [95% CI, 22°-65°], p < 0.001). Pain visual analog score improved from 8.4 ± 2.3 to 1.7 ± 2.1 (mean difference: -6.9 [95% CI, -8.7 to -5.2], p < 0.001), and Single Assessment Numeric Evaluation score improved from 28% ± 21% to 80% ± 24% (mean difference: 46% [95% CI, 28%-64%], p < 0.001). There were six major complications, five of which were treated operatively. Overall, three patients' latissimus and teres major transfer failed based on persistent lack of external rotation. In patients with posterior and superior cuff deficiency, reverse shoulder arthroplasty combined with latissimus dorsi and teres major transfer through a single deltopectoral incision can reliably increase active forward flexion and external rotation. Patients experience pain relief and functional improvement but have a high rate of complications; therefore, we recommend the procedure be limited to patients indicated for reverse who have profound external rotation loss and a high grade of infraspinatus/teres minor fatty atrophy. Level IV, therapeutic study.

  20. Arthroscopic repair of traumatic isolated subscapularis tendon lesions (Lafosse Type III or IV): a prospective magnetic resonance imaging-controlled case series with 1 year of follow-up.

    PubMed

    Grueninger, Patrick; Nikolic, Nikola; Schneider, Joerg; Lattmann, Thomas; Platz, Andreas; Chmiel, Corinne; Meier, Christoph

    2014-06-01

    The purpose of this study was to prospectively assess the efficacy of arthroscopic repair of isolated high-grade subscapularis (SSC) tendon lesions by means of clinical follow-up combined with magnetic resonance imaging investigations. Between January 2008 and September 2010, 11 patients (9 men and 2 women; mean age, 45 ± 10 years) with Lafosse type III or IV traumatic isolated SSC tendon lesions underwent arthroscopic repair including tenodesis of the long head of the biceps tendon. All patients were preoperatively assessed by clinical examination (Constant-Murley score [CMS]) and contrast-enhanced magnetic resonance arthrography. At 1 year of follow-up, specific clinical SSC tests, the CMS, and the loss of external rotation were evaluated. A native magnetic resonance investigation was performed to assess the structural integrity of the repair. The SSC muscle was compared with its preoperative condition regarding fatty infiltration and size (cross-sectional area). Patient satisfaction was graded from 1 (poor) to 4 (excellent). The mean time interval from trauma to surgery was 3.7 months. A concomitant lesion of the biceps tendon was observed in 10 patients (91%). The mean CMS improved from 44 to 89 points (P < .001). The functional tests showed a significant increase in strength (P < .05) (belly-press test, 4.8 v 2.9; lift-off test, 4.8 v 2.9). The mean loss of external rotation at 0° of abduction was 10° compared with the contralateral side (P < .05). Patient satisfaction was high. Magnetic resonance imaging evaluation showed complete structural integrity of the tendon repair in all studies. The SSC showed a significant decrease in fatty infiltration and increase in the cross-sectional area. Arthroscopic repair of higher-grade isolated SSC lesions provides reliable tendon healing accompanied by excellent functional results 1 year after surgery. Level IV, prospective therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Sonographic assessment of the subscapularis after reverse shoulder arthroplasty: impact of tendon integrity on shoulder function.

    PubMed

    Dedy, Nicolas J; Gouk, Conor J; Taylor, Fraser J; Thomas, Michael; Tan, S L Ezekiel

    2018-06-01

    The deltopectoral approach for reverse shoulder arthroplasty (RSA) requires subscapularis tenotomy or lesser tuberosity osteotomy. Whether the subscapularis should be repaired at the conclusion of the procedure remains controversial. The present study sonographically assessed the subscapularis after RSA and evaluated the effect of tendon integrity on functional outcome. All patients who had undergone RSA in the Gold Coast University Hospital between 2005 and 2016 were included. Sonography was performed by a blinded examiner. Function was assessed using the Disabilities of the Arm, Shoulder and Hand, the Constant-Murley, and Oxford Shoulder scores. Internal rotation ability was recorded on a 6-point scale. The study included 43 patients (48 shoulders). Median length of follow-up was 19 months (range, 4-132 months). On sonography, the subscapularis was graded intact in 6 shoulders (13%), intact with mild attenuation in 16 (33%), severely attenuated in 15 (31%), and not intact or absent in 11 (23%). Differences in Disabilities of the Arm, Shoulder and Hand, Constant-Murley, or Oxford Shoulder scores between intact and attenuated or absent subscapularis shoulders were not significant. Internal rotation scores were significantly higher in the intact and mildly attenuated tendon group than in the absent tendon group (U = 1.0, P = .001 and U = 28.5, P = .007, respectively). The present work is the first long-term outcome study of RSA using sonography to assess the subscapularis. Subscapularis integrity did not appear to have a measurable effect on patient outcome as measured by standard scores but was important for internal rotation ability after RSA. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  2. Phonon impedance matching: minimizing interfacial thermal resistance of thin films

    NASA Astrophysics Data System (ADS)

    Polanco, Carlos; Zhang, Jingjie; Ghosh, Avik

    2014-03-01

    The challenge to minimize interfacial thermal resistance is to allow a broad band spectrum of phonons, with non-linear dispersion and well defined translational and rotational symmetries, to cross the interface. We explain how to minimize this resistance using a frequency dependent broadening matrix that generalizes the notion of acoustic impedance to the whole phonon spectrum including symmetries. We show how to ``match'' two given materials by joining them with a single atomic layer, with a multilayer material and with a graded superlattice. Atomic layer ``matching'' requires a layer with a mass close to the arithmetic mean (or spring constant close to the harmonic mean) to favor high frequency phonon transmission. For multilayer ``matching,'' we want a material with a broadening close to the geometric mean to maximize transmission peaks. For graded superlattices, a continuous sequence of geometric means translates to an exponentially varying broadening that generates a wide-band antireflection coating for both the coherent and incoherent limits. Our results are supported by ``first principles'' calculations of thermal conductance for GaAs / Gax Al1 - x As / AlAs thin films using the Non-Equilibrium Greens Function formalism coupled with Density Functional Perturbation Theory. NSF-CAREER (QMHP 1028883), NSF-IDR (CBET 1134311), XSEDE.

  3. Effects of Two Practice Style Formats on Fifth Grade Students' Motor Skill Performance and Task Engagement

    ERIC Educational Resources Information Center

    Chatoupis, Constantine C.; Vagenas, George

    2017-01-01

    We investigated the effectiveness of two teaching formats that fall under the canopy of Mosston and Ashworth's (2008) practice style, on fifth grade students' motor skill performance and task engagement. Both formats are also known as station teaching or learning centers. In the teacher-rotated format (TR), the teacher decides the amount of time…

  4. Comparison of Two Small-Group Learning Methods in 12th-Grade Physics Classes Focusing on Intrinsic Motivation and Academic Performance

    ERIC Educational Resources Information Center

    Berger, Roland; Hanze, Martin

    2009-01-01

    Twelfth-grade physics classes with 344 students participated in a quasi-experimental study comparing two small-group learning settings. In the jigsaw classroom, in contrast to the cyclical rotation method, teaching expectancy as well as resource interdependence is established. The study is based on the self-determination theory of motivation,…

  5. A musculoskeletal model of low grade connective tissue inflammation in patients with thyroid associated ophthalmopathy (TAO): the WOMED concept of lateral tension and its general implications in disease

    PubMed Central

    Moncayo, Roy; Moncayo, Helga

    2007-01-01

    Background Low level connective tissue inflammation has been proposed to play a role in thyroid associated ophthalmopathy (TAO). The aim of this study was to investigate this postulate by a musculoskeletal approach together with biochemical parameters. Methods 13 patients with TAO and 16 controls were examined. Erythrocyte levels of Zn, Cu, Ca2+, Mg, and Fe were determined. The musculoskeletal evaluation included observational data on body posture with emphasis on the orbit-head region. The angular foot position in the frontal plane was quantified following gait observation. The axial orientation of the legs and feet was evaluated in an unloaded supine position. Functional propioceptive tests based on stretch stimuli were done by using foot inversion and foot rotation. Results Alterations in the control group included neck tilt in 3 cases, asymmetrical foot angle during gait in 2, and a reaction to foot inversion in 5 cases. TAO patients presented facial asymmetry with displaced eye fissure inclination (mean 9.1°) as well as tilted head-on-neck position (mean 5.7°). A further asymmetry feature was external rotation of the legs and feet (mean 27°). Both foot inversion as well as foot rotation induced a condition of neuromuscular deficit. This condition could be regulated by gentle acupressure either on the lateral abdomen or the lateral ankle at the acupuncture points gall bladder 26 or bladder 62, respectively. In 5 patients, foot rotation produced a phenomenon of moving toes in the contra lateral foot. In addition foot rotation was accompanied by an audible tendon snapping. Lower erythrocyte Zn levels and altered correlations between Ca2+, Mg, and Fe were found in TAO. Conclusion This whole body observational study has revealed axial deviations and body asymmetry as well as the phenomenon of moving toes in TAO. The most common finding was an arch-like displacement of the body, i.e. eccentric position, with foot inversion and head tilt to the contra lateral side and tendon snapping. We propose that eccentric muscle action over time can be the basis for a low grade inflammatory condition. The general implications of this model and its relations to Zn and Se will be discussed. PMID:17319961

  6. Effect of Modeling-Based Activities Developed Using Virtual Environments and Concrete Objects on Spatial Thinking and Mental Rotation Skills

    ERIC Educational Resources Information Center

    Yurt, Eyup; Sunbul, Ali Murat

    2012-01-01

    In this study, the effect of modeling based activities using virtual environments and concrete objects on spatial thinking and mental rotation skills was investigated. The study was designed as a pretest-posttest model with a control group, which is one of the experimental research models. The study was carried out on sixth grade students…

  7. Treatment of segmental tibial fractures with supercutaneous plating.

    PubMed

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  8. Evidence for minimally invasive therapies in the management of chronic calcific tendinopathy of the rotator cuff: a systematic review and meta-analysis.

    PubMed

    Louwerens, Jan K G; Sierevelt, Inger N; van Noort, Arthur; van den Bekerom, Michel P J

    2014-08-01

    This meta-analysis assessed the short-term to midterm effectiveness of minimally invasive treatments in the management of calcifying tendinopathy of the shoulder cuff, a common source of chronic shoulder pain that leads to pain, a decreased active range of motion, and loss of muscular strength. When conservative therapies fail, minimally invasive treatment options can be considered before resulting to surgery. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed to conduct this review. A systematic literature search was conducted in May 2013 to identify all studies that examined the short-term to midterm effectiveness of minimally invasive treatments for chronic calcifying tendinopathy. The primary end points were identified as function, pain, and total resorption rates. Grades of Recommendation Assessment, Development and Evaluation (GRADE) was used to assess the quality of evidence. Included were 20 studies (1544 participants). Common methodological flaws were related to randomization. In general, there is moderate-quality GRADE evidence that high-energy extracorporeal shockwave therapy has a significant effect on pain relief and functional status compared with other interventions. There is variable-quality GRADE evidence on the efficiency of other interventions. High-energy extracorporeal shockwave therapy is the most thoroughly investigated minimally invasive treatment option in the short-term to midterm and has proven to be a safe and effective treatment. Ultrasound-guided needling is safe but has not been proven to be more effective than an ultrasound-guided subacromial corticosteroid injection in recent level I research, and further research will have to prove its effectiveness. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  9. Platelet-rich plasma in arthroscopic rotator cuff repair: a meta-analysis of randomized controlled trials.

    PubMed

    Zhao, Jia-Guo; Zhao, Li; Jiang, Yan-Xia; Wang, Zeng-Liang; Wang, Jia; Zhang, Peng

    2015-01-01

    The purpose of this study was to appraise the retear rate and clinical outcomes of platelet-rich plasma use in patients undergoing arthroscopic full-thickness rotator cuff repair. We searched the Cochrane Library, PubMed, and EMBASE databases for randomized controlled trials comparing the outcomes of arthroscopic rotator cuff surgery with or without the use of platelet-rich plasma. Methodological quality was assessed by the Detsky quality scale. When there was no high heterogeneity, we used a fixed-effects model. Dichotomous variables were presented as risk ratios (RRs) with 95% confidence intervals (CIs), and continuous data were measured as mean differences with 95% CIs. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system was used to assess the quality of evidence for each individual outcome. Eight randomized controlled trials were included, with the sample size ranging from 28 to 88. Overall methodological quality was high. Fixed-effects analysis showed that differences were not significant between the 2 groups in retear rate (RR, 0.94; 95% CI, 0.70 to 1.25; P = .66), Constant score (mean difference, 1.12; 95% CI, -1.38 to 3.61; P = .38), and University of California at Los Angeles (UCLA) score (mean difference, -0.68; 95% CI, -2.00 to 0.65; P = .32). The strength of GRADE evidence was categorized respectively as low for retear, moderate for Constant score, and low for UCLA shoulder score. Our meta-analysis does not support the use of platelet-rich plasma in the arthroscopic repair of full-thickness rotator cuff tears over repairs without platelet-rich plasma because of similar retear rates and clinical outcomes. Level II, meta-analysis of Level I and II randomized controlled trials. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. Half forehead reconstruction with a single rotational scalp flap for dermatofibrosarcoma protuberans treatment

    PubMed Central

    2012-01-01

    Background Dermatofibrosarcoma protuberans (DFSP) is a soft tissue neoplasm of intermediate to low-grade malignancy. Although metastasis rarely occurs, DFSP has a locally aggressive behavior with a high recurrence rate. In the head and neck area, resection involving a wide margin of healthy tissue can be difficult because of functional and cosmetic considerations. We describe a novel reconstructive method for half forehead defects with an innovative single local wide scalp flap following excision of DFSP with a 3 cm margin of healthy tissue. Methods Two patients underwent wide resection of forehead DFSP and reconstruction with a single rotational scalp flap. The scalp flap blood supply was provided from three main vessels: the superficial temporal artery, occipital artery and posterior auricular artery. Results No early or late complications were observed in either patient with no local recurrence after 18 months of follow-up. The donor area could be closed primarily in both cases and the flaps survived completely. Conclusion This innovative technique allowed a radical excision of forehead DFSP with sufficient healthy margins, thus potentially decreasing tumor recurrence rate. Reconstruction was achieved avoiding microsurgery, skin expanders and large skin grafts. Moreover, all main reconstructive criteria, such as functional and cosmetic tissue characteristics, were completely fulfilled. PMID:22559860

  11. The Kinematics and Spondylosis of the Lumbar Spine Vary Depending on the Levels of Motion Segments in Individuals With Low Back Pain.

    PubMed

    Basques, Bryce A; Espinoza Orías, Alejandro A; Shifflett, Grant D; Fice, Michael P; Andersson, Gunnar B; An, Howard S; Inoue, Nozomu

    2017-07-01

    A prospective cohort study. The aim of this study was to identify associations of spondylotic and kinematic changes with low back pain (LBP). The ability to characterize and differentiate the biomechanics of both the symptomatic and asymptomatic lumbar spine is crucial to alleviate the sparse literature on the association of lumbar spine biomechanics and LBP. Lumbar dynamic plain radiographs (flexion-extension), dynamic computed tomography (CT) scanning (axial rotation, disc height), and magnetic resonance imaging (MRI, disc and facet degeneration grades) were obtained for each subject. These parameters were compared between symptomatic and control groups using Student t test and multivariate logistic regression, which controlled for patient age and sex and identified spinal parameters that were independently associated with symptomatic LBP. Disc grade and mean segmental motion by level were tested by one-way analysis of variance (ANOVA). Ninety-nine volunteers (64 asymptomatic/35 LBP) were prospectively recruited. Mean age was 37.3 ± 10.1 years and 55% were male. LBP showed association with increased L5/S1 translation [odds ratio (OR) 1.63 per mm, P = 0.005], decreased flexion-extension motion at L1/L2 (OR 0.87 per degree, P = 0.036), L2/L3 (OR 0.88 per degree, P = 0.036), and L4/L5 (OR 0.87 per degree, P = 0.020), increased axial rotation at L4/L5 (OR 2.11 per degree, P = 0.032), decreased disc height at L3/L4 (OR 0.52 per mm, P = 0.008) and L4/L5 (OR 0.37 per mm, p < 0.001), increased disc grade at all levels (ORs 2.01-12.33 per grade, P = 0.001-0.026), and increased facet grade at L4/L5 (OR 4.99 per grade, P = 0.001) and L5/S1 (OR 3.52 per grade, P = 0.004). Significant associations were found between disc grade and kinematic parameters (flexion-extension motion, axial rotation, and translation) at L4/L5 (P = 0.001) and L5/S1 (P < 0.001), but not at other levels (P > 0.05). In symptomatic individuals, L4/L5 and L5/S1 levels were affected by spondylosis and kinematic changes. This study clarifies the relationships between kinematic alterations and LBP, mostly observed at the above-mentioned segments. N/A.

  12. Agricultural produce grading and sorting system using color CCD and new color identification algorithm

    NASA Astrophysics Data System (ADS)

    Wang, Dongsheng; Zou, Jizuo; Yang, Yunping; Dong, Jianhua; Zhang, Yuanxiang

    1996-10-01

    A high-speed automatic agricultural produce grading and sorting system using color CCD and new color identification algorithm has been developed. In a typical application, the system can sort almonds into tow output grades according to their color. Almonds ar rich in 18 kinds of amino acids and 13 kinds of micro minerals and vitamins and can be made into almond drink. In order to ensure the drink quality, almonds must be sorted carefully before being made into a drink. Using this system, almonds can be sorted into two grades: up to grade and below grade almonds or foreign materials. A color CCD inspects the almonds passing on a conveyor of rotating rollers, a color identification algorithm grades almonds and distinguishes foreign materials from almonds. Employing an elaborately designed mechanism, the below grade almonds and foreign materials can be removed effectively from the raw almonds. This system can be easily adapted for inspecting and sorting other kinds of agricultural produce such as peanuts, beans tomatoes and so on.

  13. Spatial ability mediates the gender difference in middle school students' science performance.

    PubMed

    Ganley, Colleen M; Vasilyeva, Marina; Dulaney, Alana

    2014-01-01

    Prior research has demonstrated a male advantage in spatial skills and science achievement. The present research integrated these findings by testing the potential role of spatial skills in gender differences in the science performance of eighth-grade students (13-15 years old). In (N = 113), the findings showed that mental rotation ability mediated gender differences in physical science and technology/engineering test scores. In (N = 73,245), science performance was examined in a state population of eighth-grade students. As in , the results revealed larger gender differences on items that showed higher correlations with mental rotation. These findings underscore the importance of considering spatial training interventions aimed at reducing gender differences in the science performance of school-aged children. © 2014 The Authors. Child Development © 2014 Society for Research in Child Development, Inc.

  14. SPORT: Radiographic Predictors of Clinical Outcomes Following Operative or Non-operative Treatment of Degenerative Spondylolisthesis

    PubMed Central

    Pearson, Adam M.; Lurie, Jon D.; Blood, Emily A.; Frymoyer, John W.; Braeutigam, Heike; An, Howard; Girardi, Federico P.; Weinstein, James N.

    2009-01-01

    STUDY DESIGN Subgroup analyses according to treatment received. OBJECTIVES To evaluate whether baseline radiographic findings predicted outcomes in patients with degenerative spondylolisthesis (DS). SUMMARY OF BACKGROUND DATA The SPORT combined randomized and observational DS cohorts. METHODS The Meyerding listhesis grade was determined on the neutral radiograph (n=222). Patients were classified as having low disk height if disk height was less than 5 mm. Flexion-extension radiographs (n=185) were evaluated for mobility. Those with greater than 10° rotation or 4mm translation were considered Hypermobile. Changes in outcome measures were compared between listhesis (Grade 1 vs. Grade 2), disk height (Low vs. Normal) and mobility (Stable vs. Hypermobile) groups using longitudinal regression models adjusted for potential confounders. Outcome measures included SF-36 bodily pain (BP) and physical function (PF) scales, Oswestry disability index (ODI), stenosis bothersomeness index (SBI), and low back pain bothersomeness scale. RESULTS Overall, 86% had a Grade 1 listhesis, 78% had Normal disk height, and 73% were Stable. Baseline symptom severity was similar between groups. Overall, surgery patients improved more than patients treated non-operatively. At one year, outcomes were similar in surgery patients across listhesis, disk height, and mobility groups (ODI: Grade 1 -23.7 vs. Grade 2 -23.3, p=0.90; Normal disk height-23.5 vs. Low disk height -21.9, p=0.66; Stable -21.6 vs. Hypermobile -25.2, p=0.30). Among those treated nonoperatively, Grade 1 patients improved more than Grade 2 patients (BP +13.1 vs. -4.9, p=0.019; ODI -8.0 vs. +4.8, p=0.010 at 1 year), and Hypermobile patients improved more than Stable patients (ODI -15.2 vs -6.6, p=0.041; SBI -7.8 vs -2.7, p=0.002 at 1 year). DISCUSSION Regardless of listhesis grade, disk height or mobility, patients who had surgery improved more than those treated non-operatively. These differences were due, in part, to differences in non-operative outcomes, which were better in patients classified as Grade 1 or Hypermobile. PMID:19050582

  15. Factors affecting rotator cuff healing after arthroscopic repair: osteoporosis as one of the independent risk factors.

    PubMed

    Chung, Seok Won; Oh, Joo Han; Gong, Hyun Sik; Kim, Joon Yub; Kim, Sae Hoon

    2011-10-01

    The prognostic factors associated with structural outcome after arthroscopic rotator cuff repair have not yet been fully determined. The hypothesis of this study was that bone mineral density (BMD) is an important prognostic factor affecting rotator cuff healing after arthroscopic cuff repair. Cohort study; Level of evidence, 3. Among 408 patients who underwent arthroscopic repair for full-thickness rotator cuff tear between January 2004 and July 2008, 272 patients were included whose postoperative cuff integrity was verified by computed tomography arthrography (CTA) or ultrasonography (USG) and simultaneously who were evaluated by various functional outcome instruments. The mean age at the time of operation was 59.5 ± 7.9 years. Postoperative CTA or USG was performed at a mean 13.0 ± 5.1 months after surgery, and the mean follow-up period was 37.2 ± 10.0 months (range, 24-65 months). The clinical, structural, and surgery-related factors affecting cuff integrity including BMD were analyzed using both univariate and multivariate analysis. Evaluation of postoperative cuff integrity was performed by musculoskeletal radiologists who were unaware of the present study. The failure rate of rotator cuff healing was 22.8% (62 of 272). The failure rate was significantly higher in patients with lower BMD (P < .001); older age (P < .001); female gender (P = .03); larger tear size (P < .001); higher grade of fatty infiltration (FI) of the supraspinatus, infraspinatus, and subscapularis (all P < .001); diabetes mellitus (P = .02); shorter acromiohumeral distance (P < .001); and associated biceps procedure (P < .001). However, in the multivariate analysis, only BMD (P = .001), FI of the infraspinatus (P = .01), and the amount of retraction (P = .03) showed a significant relationship with cuff healing failure following arthroscopic rotator cuff repair. Bone mineral density, as well as FI of the infraspinatus and amount of retraction, was an independent determining factor affecting postoperative rotator cuff healing. Further studies with prospective, randomized, and controlled design are needed to confirm the relationship between BMD and postoperative rotator cuff healing.

  16. Time-dependent flow model of a generalized Burgers' fluid with fractional derivatives through a cylindrical domain: An exact and numerical approach

    NASA Astrophysics Data System (ADS)

    Safdar, Rabia; Imran, M.; Khalique, Chaudry Masood

    2018-06-01

    Exact solutions for velocity field and tangential stress for rotational flow of a generalized Burgers' fluid within an infinite circular pipe are derived by using the methods of Laplace and finite Hankel transformations. Firstly we take the position of fluid at rest and then the fluid flow due to the rotation of the pipe around the axis of flow having time dependant angular velocity. The exact solutions are presented in terms of the generalized Ga,b,c (., t) -functions. The corresponding results can be freely specified for the same results of Burgers', Oldroyd B, Maxwell, second grade and Newtonian fluids (performing the same motion) as particular cases of the results obtained earlier. The impact of the different parameters, individually and in comparison, are represented by graphical demonstrations. Secondly the numerical solutions for velocity and stress are also obtained with the help of Laplace transformation, Gaver Stehfest's algorithm and MATHCAD. Finally a comparison of both methods for the same problem is done and shows the consistency of results.

  17. Long-term outcome of pronation-external rotation ankle fractures treated with syndesmotic screws only.

    PubMed

    Lambers, Kaj T A; van den Bekerom, Michel P J; Doornberg, Job N; Stufkens, Sjoerd A S; van Dijk, C Niek; Kloen, Peter

    2013-09-04

    There is sparse information in the literature on the outcome of Maisonneuve-type pronation-external rotation ankle fractures treated with syndesmotic screws. The primary aim of this study was to determine the long-term results of such treatment of these fractures as indicated by standardized patient-based and physician-based outcome measures. The secondary aim was to identify predictors of the outcome with use of bivariate and multivariate statistical analysis. Fifty patients with pronation-external rotation (predominantly Maisonneuve) fractures were treated with open reduction and internal fixation of the syndesmosis utilizing only one or two screws. The results were evaluated at a mean of twenty-one years after the fracture utilizing three standardized outcomes instruments: (1) the Foot and Ankle Ability Measure (FAAM), (2) the American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot scale, and (3) the Center for Epidemiologic Studies-Depression (CES-D) Scale. Osteoarthritis was graded according to the van Dijk and revised Takakura radiographic scoring systems. Bivariate and multivariate analyses were performed to identify predictors of long-term outcome. Forty-four (92%) of forty-eighty patients had good or excellent AOFAS scores, and forty-four (90%) of forty-nine had good or excellent FAAM scores. Arthrodesis for severe osteoarthritis was performed in two patients. Radiographic evidence of osteoarthritis was observed in twenty-four (49%) of forty-nine patients. Multivariate analysis identified pain as the most important independent predictor of long-term ankle function as indicated by the AOFAS and FAAM scores, explaining 91% and 53% of the variation in scores, respectively. Analysis of pain as the dependent variable in bivariate analyses revealed that depression, ankle range of motion, and a subsequent surgery were significantly correlated with higher pain scores. No firm conclusions could be drawn after multivariate analysis of predictors of pain. Long-term functional outcomes at a mean of twenty-one years after pronation-external rotation ankle fractures treated with one or two syndesmotic screws were good to excellent in the great majority of patients despite substantial radiographic evidence of osteoarthritis in one-half of the patients. The most important predictor of long-term functional outcome was patient-reported pain rather than physician-reported function or posttraumatic osteoarthritis. There was no significant association between radiographic signs of posttraumatic osteoarthritis and perceived pain in the present series.

  18. The extrudate swell of HDPE: Rheological effects

    NASA Astrophysics Data System (ADS)

    Konaganti, Vinod Kumar; Ansari, Mahmoud; Mitsoulis, Evan; Hatzikiriakos, Savvas G.

    2017-05-01

    The extrudate swell of an industrial grade high molecular weight high-density polyethylene (HDPE) in capillary dies is studied experimentally and numerically using the integral K-BKZ constitutive model. The non-linear viscoelastic flow properties of the polymer resin are studied for a broad range of large step shear strains and high shear rates using the cone partitioned plate (CPP) geometry of the stress/strain controlled rotational rheometer. This allowed the determination of the rheological parameters accurately, in particular the damping function, which is proven to be the most important in simulating transient flows such as extrudate swell. A series of simulations performed using the integral K-BKZ Wagner model with different values of the Wagner exponent n, ranging from n=0.15 to 0.5, demonstrates that the extrudate swell predictions are extremely sensitive to the Wagner damping function exponent. Using the correct n-value resulted in extrudate swell predictions that are in excellent agreement with experimental measurements.

  19. X-ray diffraction, IR spectroscopy and thermal characterization of partially hydrolyzed guar gum.

    PubMed

    Mudgil, Deepak; Barak, Sheweta; Khatkar, B S

    2012-05-01

    Guar gum was hydrolyzed using cellulase from Aspergillus niger at 5.6 pH and 50°C temperature. Hydrolyzed guar gum sample was characterized using Fourier transform infrared spectroscopy, differential scanning calorimetry, thermogravimetric analysis, X-ray diffraction, dilute solution viscometry and rotational viscometry. Viscometry analysis of native guar gum showed a molecular weight of 889742.06, whereas, after enzymatic hydrolysis, the resultant product had a molecular weight of 7936.5. IR spectral analysis suggests that after enzymatic hydrolysis of guar gum there was no major transformation of functional group. Thermal analysis revealed no major change in thermal behavior of hydrolyzed guar gum. It was shown that partial hydrolysis of guar gum could be achieved by inexpensive and food grade cellulase (Aspergillus niger) having commercial importance and utilization as a functional soluble dietary fiber for food industry. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Patellofemoral pain and asymmetrical hip rotation.

    PubMed

    Cibulka, Michael T; Threlkeld-Watkins, Julie

    2005-11-01

    Patellofemoral joint problems are the most common overuse injury of the lower extremity, and altered femoral or hip rotation may play a role in patellofemoral pain. The purpose of this case report is to describe the evaluation of and intervention for a patient with asymmetrical hip rotation and patellofemoral pain. The patient was a 15-year-old girl with an 8-month history of anterior right knee pain, without known trauma or injury. Prior to intervention, her score on the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) was 24%. Right hip medial (internal) rotation was less than left hip medial rotation, and manual muscle testing showed weakness of the right hip internal rotator and abductor muscles. The intervention was aimed at increasing right hip medial rotation, improving right hip muscle strength (eg, the muscle force exerted by a muscle or a group of muscles to overcome a resistance), and eliminating anterior right knee pain. After 6 visits (14 days), passive left and right hip medial rotations were symmetrical, and her right hip internal rotator and abductor muscle grades were Good plus. Her WOMAC score was 0%. The patient had right patellofemoral pain and an uncommon pattern of asymmetrical hip rotation, with diminished hip medial rotation and excessive hip lateral (external) rotation on the right side. The patient's outcomes suggest that femoral or hip joint asymmetry may be related to patellofemoral joint pain.

  1. Does The Sun Rotate Around The Earth Or Does The Earth Rotate Around the Sun? An Important Key to Evaluating Science Education

    NASA Astrophysics Data System (ADS)

    Isobe, S.

    2006-08-01

    The Japan Spaceguard Association, Tokyo, Japan Sciences are continuously developing. This is a good situation for the sciences, but when one tries to teach scientific results, it is hard to decide which levels of science should be taught in schools. The point to evaluate is not only the quality of scientific accuracy, but also the method with which school students of different scientific abilities study scientific results. In astronomy, an important question, which is "Does the Sun rotate around the Earth or does the Earth rotate around the Sun?" can be used to evaluate student abilities. Scientifically, it is obvious that the latter choice is the better answer, but it is not so obvious for the lower-grade students and also for the lower-ability students even in the higher grades. If one sees daily the sky without scientific knowledge, one has an impression of "the Sun rotates around the Earth," and for his rest of his life he will not see any problem. If one wants to be a scientist, though, he should know that "the Earth rotates around the Sun" before reaching university level. If he will become a physical scientist, he should understand that it is not correct to say "the Earth rotates around the Sun," but he should know that the Earth rotates around the center of gravity of the solar system. A similar type of question is "has the Earth the shape of a sphere, or a pear, or a geoid?" There are many teachers with varying ranges of students who do not understand the proper level of science instruction. When students of lower capacity are instructed to understand concepts with the higher degrees of sophistication, they can easily lose their interest in the sciences. This happens in many countries, especially in Japan, where there are many different types of people with different jobs. We, as educators, should appreciate that the students can be interested in any given scientific idea, no matter what level of sophistication it is.

  2. Management of acetabular fractures with modified posterior approach to spare external hip rotators.

    PubMed

    Sarlak, Ahmet Y; Selek, Ozgur; Inanir, Murat; Musaoglu, Resul; Baran, Tuncay

    2014-04-01

    In the present study the quality of reduction and incidence of complications in hip external rotator sparing modified posterior approach was assessed in both simple and complex acetabular fractures. This retrospective study includes 37 patients (38 hips) with a mean age of 42.1 years (range 21-60), that had been treated for displaced acetabular fractures from June 2007 through May 2011. They were reviewed at a mean of 3 years (20-67 months). The fractures were classified according to the Letournel-Judet classification. Anatomic reduction and stable fixation of the fracture with less than 2mm residual displacement was achieved in 28 of 38 hips. At the final follow up the patients were evaluated clinically according to Merle d'Aubigne and Postel scoring system which had been modified by Matta and radiologically based on the criteria described by Matta. The clinical results were excellent in 20, good in 8, fair in 8, and poor 2 hips. Complications included two superficial local wound infection and 10 heterotopic ossification with 7 of the cases having grade I heterotopic ossification. Avascular necrosis of the femoral head was not seen in any of the 38 hips. One patient with preoperative sciatic nerve palsy had complete recovery of neurologic function. There were no cases of deep vein thrombosis or pulmonary embolism. The functional outcome was satisfactory in most of the cases and comparable with other larger series. Using the limited part of Henry's sciatic nerve exposure skin incision - working in the plane between gluteus maximus and the tensor fascia lata as in the classical Gibson approach and two portal external rotator hip sparing approach resulted in good fracture reduction without approach related complications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Graded motor imagery and the impact on pain processing in a case of CRPS.

    PubMed

    Walz, Andrea D; Usichenko, Taras; Moseley, G Lorimer; Lotze, Martin

    2013-03-01

    Graded motor imagery (GMI) shows promising results for patients with complex regional pain syndrome (CRPS). In a case with chronic unilateral CRPS type I, we applied GMI for 6 weeks and recorded clinical parameters and cerebral activation using functional magnetic resonance imaging (fMRI; pre-GMI, after each GMI block, and after 6 mo). Changes in fMRI activity were mapped during movement execution in areas associated with pain processing. A healthy participant served as a control for habituation effects. Pain intensity decreased over the course of GMI, and relief was maintained at follow-up. fMRI during movement execution revealed marked changes in S1 and S2 (areas of discriminative pain processing), which seemed to be associated with pain reduction, but none in the anterior insula and the anterior cingulate cortex (areas of affective pain processing). After mental rotation training, the activation intensity of the posterior parietal cortex was reduced to one third. Our case report develops a design capable of differentiating cerebral changes associated with behavioral therapy of CRPS type I study.

  4. Quasi-radial modes of rotating stars in general relativity

    NASA Astrophysics Data System (ADS)

    Yoshida, Shin'ichirou; Eriguchi, Yoshiharu

    2001-04-01

    By using the Cowling approximation, quasi-radial modes of rotating general relativistic stars are computed along equilibrium sequences from non-rotating to maximally rotating models. The eigenfrequencies of these modes are decreasing functions of the rotational frequency. The eigenfrequency curve of each mode as a function of the rotational frequency has discontinuities, which arise from the avoided crossing with other curves of axisymmetric modes.

  5. Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears.

    PubMed

    Zhang, Chun-Gang; Zhao, De-Wei; Wang, Wei-Ming; Ren, Ming-Fa; Li, Rui-Xin; Yang, Sheng; Liu, Yu-Peng

    2010-11-01

    For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of ≤ 45° into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Gap formation for the transtendon single-row repair was significantly smaller (P < 0.05) when compared with the double-row repair for the first cycle ((1.74 ± 0.38) mm vs. (2.86 ± 0.46) mm, respectively) and the last cycle ((3.77 ± 0.45) mm vs. (5.89 ± 0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P < 0.05) when compared with the double-row repair. Also, it had a higher mean ultimate tensile load and stiffness. For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation.

  6. Asymptomatic rotator cuff tears: Patient demographics and baseline shoulder function

    PubMed Central

    Keener, Jay D.; Steger-May, Karen; Stobbs, Georgia; Yamaguchi, Ken

    2010-01-01

    Background The purpose of this study is to characterize the demographic features and physical function of subjects with asymptomatic rotator cuff tears and to compare their shoulder function to controls with an intact rotator cuff. Materials and Methods 196 subjects with an asymptomatic rotator cuff tear and 54 subjects with an intact rotator cuff presenting with a painful rotator cuff tear in the contralateral shoulder were enrolled. Various demographic features, shoulder function (ASES score and SST score), range of motion and strength were compared. Results The demographic features of the study and control groups were similar. Hand dominance was associated with the presence of shoulder pain (p < .05). Subjects with an intact rotator cuff had greater but clinically insignificant ASES (p < .05) and SST scores (p < .05) than those with an asymptomatic tear. No differences in functional scores, range of motion or strength were seen between partial (n=61) and full-thickness tears (n=135). Of the full-thickness tears, 36 (27%) were classified as small, 85 (63%) as medium and 14 (10%) as large tears. No differences were seen in functional scores between full-thickness tears of various sizes. Conclusions When asymptomatic, a rotator cuff tear is associated with a clinically insignificant loss of shoulder function compared to those with an intact rotator cuff. Therefore, a clinically detectable decline in shoulder function may indicate an “at-risk” asymptomatic tear. The presence of pain is important in cuff deficient shoulders for creating a measurable loss of shoulder function. Hand dominance appears to be an important risk factor for pain. PMID:21030274

  7. Polycrystalline (TbXY1-X)2O3 Faraday rotator.

    PubMed

    Ikesue, Akio; Aung, Yan Lin; Makikawa, Shinji; Yahagi, Akira

    2017-11-01

    We have succeeded for the first time in synthesizing an optical grade (Tb X Y 1-X ) 2 O 3 (X=0.5-1.0) ceramic Faraday rotator, which greatly exceeds the basic characteristics of the commercial terbium gallium garnet (TGG) (Tb 3 Ga 5 O 12 ) crystal. The Faraday rotation angle increased as the Tb concentration increased, and the Verdet constant increased from 2.1 (82  rad T -1  m -1 at X=0.5) to 3.8 times (154  rad T -1  m -1 at X=1.0) than the TGG single crystal, which is regarded as highest class. Therefore, it is possible to minimize the Faraday rotator length and the magnet in building an optical isolator. It was also confirmed that its optical quality was very comparable to the commercial TGG crystal.

  8. [Intramedullary nailing of the tibia with the expert tibia nail].

    PubMed

    Hansen, Matthias; El Attal, René; Blum, Jochen; Blauth, Michael; Rommens, Pol Maria

    2009-12-01

    Restoration of axis, length, and rotation of the lower leg. Sufficient primary stability of the osteosynthesis for functional aftercare. Early functional aftercare to maintain joint mobility. Good bony healing in closed and open fractures. All closed and open fractures of the tibia and complete lower leg fractures (AO 42). Certain extraarticular fractures of the proximal and distal tibia (AO 41 A2/A3; AO 43 A1/A2/A3). Segmental fractures of the tibia. Certain intraarticular fractures of the tibia with use of additional implants (AO 41 C1/C2; AO 43 C1/C2). Stabilization during and after segmental bone transport or callus distraction of the tibia. Patients in poor general condition (e.g., bedridden). Flexion of the knee of less than 90 degrees . Infection in the nail's insertion area. Infection of the tibial cavity. Complex articular fractures of the proximal or distal tibia with joint depression. Closed reduction of the fracture. If necessary, use of reduction clamps through additional stab incisions or open surgical procedures. In some cases, additional osteosynthesis procedures are necessary (e.g., screws). Positioning of the patient may be performed on a radiolucent table or a traction table. Opening of the proximal tibia in line with the medullary canal. Cannulated or noncannulated insertion of the Expert Tibia Nail((R)) with or without reaming of the medullary canal depending on the fracture type and soft-tissue condition. Control of axis, length, and rotation. Distal interlocking with the radiolucent drill and proximal interlocking with the targeting device. Immediate mobilization of ankle joint and knee joint. Depending on the type of fracture, mobilization with 20 kg partial weight bearing or pain-dependent full weight bearing with crutches. X-ray control 6 weeks postoperatively and increased weight bearing depending on the fracture status. In a prospective, international multicentric study, 181 patients with 186 fractures were included between July 2004 and May 2005. 57 of these fractures (30.7%) initially were graded open, 15 of them grade I, 32 grade II, and ten grade III. Most of the fractures (36%) were shaft fractures. After 1 year, 146 patients (81%) could be evaluated clinically and radiologically. The overall pseudarthrosis rate was 12.2% (18.2% for open and 9.7% for closed fractures). The risk for secondary operations or revisions (including dynamization of the nail) was 18.8%. Without consideration of dynamization procedures, revisions were necessary in only 5.4% of all patients. The risk for varus, valgus or antecurvation malalignment of more than 5 degrees in any plane on radiologic long leg views was 4.3% for shaft fractures, 1.5% for distal fractures, and 13.6% for proximal fractures. The implant-specific risk for bolt breakage was 3.2%.

  9. Factors affecting femoral rotational angle based on the posterior condylar axis in gap-based navigation-assisted total knee arthroplasty for valgus knee.

    PubMed

    Lee, Sung-Sahn; Lee, Yong-In; Kim, Dong-Uk; Lee, Dae-Hee; Moon, Young-Wan

    2018-01-01

    Achieving proper rotational alignment of the femoral component in total knee arthroplasty (TKA) for valgus knee is challenging because of lateral condylar hypoplasia and lateral cartilage erosion. Gap-based navigation-assisted TKA enables surgeons to determine the angle of femoral component rotation (FCR) based on the posterior condylar axis. This study evaluated the possible factors that affect the rotational alignment of the femoral component based on the posterior condylar axis. Between 2008 and 2016, 28 knees were enrolled. The dependent variable for this study was FCR based on the posterior condylar axis, which was obtained from the navigation system archives. Multiple regression analysis was conducted to identify factors that might predict FCR, including body mass index (BMI), Kellgren-Lawrence grade (K-L grade), lateral distal femoral angles obtained from the navigation system and radiographs (NaviLDFA, XrayLDFA), hip-knee-ankle (HKA) axis, lateral gap under varus stress (LGVS), medial gap under valgus stress (MGVS), and side-to-side difference (STSD, MGVS - LGVS). The mean FCR was 6.1° ± 2.0°. Of all the potentially predictive factors evaluated in this study, only NaviLDFA (β = -0.668) and XrayLDFA (β = -0.714) predicted significantly FCR. The LDFAs, as determined using radiographs and the navigation system, were both predictive of the rotational alignment of the femoral component based on the posterior condylar axis in gap-based TKA for valgus knee. A 1° increment with NaviLDFA led to a 0.668° decrement in FCR, and a 1° increment with XrayLDFA led to a 0.714° decrement. This suggests that symmetrical lateral condylar hypoplasia of the posterior and distal side occurs in lateral compartment end-stage osteoarthritis with valgus deformity.

  10. Posterior corrective surgery for moderate to severe focal kyphosis in the thoracolumbar spine: 57 cases with minimum 3 years follow-up.

    PubMed

    Zeng, Yan; Qu, Xiaochen; Chen, Zhongqiang; Yang, Xiaoxi; Guo, Zhaoqing; Qi, Qiang; Li, Weishi; Sun, Chuiguo

    2017-07-01

    To evaluate the radiological and clinical outcomes of the corrective surgery for patients with moderate to severe focal kyphosis in thoracolumbar spine. Fifty-seven patients with moderate to severe focal kyphosis of the thoracolumbar spine underwent apical segmental resection osteotomy with dual axial rotation correction at our hospital. There were 30 male and 27 female patients. The mean age was 34.3 years. The kyphosis level radiographs were obtained from each patient before surgery, immediately after surgery and at follow-up. Local kyphosis and scoliosis Cobb angles were measured. Full-spine standing radiographs were obtained before surgery and at follow-up, and the spine sagittal and coronal balance were evaluated. The height of patients, the Frankel grading system for neurological functions, the Oswestry disability index for life quality, the visual analogue score for back pain and the patient satisfactory index for satisfaction to surgery were applied before surgery and at follow-up. The radiological and clinical outcomes were further analyzed in different sub-groups of patients according to etiology, severity of kyphosis, age, level of kyphosis apex, Frankel grade before surgery, and complications. The average follow-up time of patients was 46.1 months. The average kyphosis angle reduced from 94.6° before surgery to 31.0° immediately after surgery, and remained at 34.4° at follow-up. The sagittal balance of the spine, height of patients, Frankel grading, Oswestry disability index and visual analogue score were improved. The patient satisfactory index (PSI) showed a satisfied rate of 91.2%. The correction rate was significantly higher in patients with kyphosis angle less than 95° and age less than 35 years. The clinical improvement rate was significantly higher in patient with kyphosis apex at lower thoracic spine or thoracolumbar segment, Frankel grade E before surgery and no complication group. The incidence of intra-operative and early stage complications was 38.6%, and the incidence of instrumentation failure was 10.5%. The most severe complication was transient spinal cord injury, and the incidence was 7.0%. All complications got good relief after appropriate intervention. Apical segmental resection osteotomy with dual axial rotation correction is an effective procedure to treat moderate to severe focal kyphosis, the prevention of serious neurological complications is fundamental to achieve the ideal clinical results.

  11. Ultrasound-guided shoulder MR arthrography: comparison of rotator interval and posterior approach.

    PubMed

    Ogul, Hayri; Bayraktutan, Ummugulsum; Ozgokce, Mesut; Tuncer, Kutsi; Yuce, Ihsan; Yalcin, Ahmet; Pirimoglu, Berhan; Sagsoz, Erdem; Kantarci, Mecit

    2014-01-01

    The purpose of this study was to prospectively evaluate the two different ultrasound-guided injection techniques for magnetic resonance (MR) arthrography of the shoulder. This study included 100 patients [50 rotator interval group (n=50) vs. 50 posterior approach group (n=50)]. All procedures were performed by the same radiologist. The two injection techniques were compared. The discomfort during and after arthrography was evaluated. Extraarticular contrast media extravasation was graded according to the MRI findings. The number of injection attempts, effect of contrast media extravasation rate on diagnostic quality and procedure times were recorded. There were no significant difference between the posterior and rotator interval puncture groups with regard to pain (P=.915), procedure times (P=.401) or attempt scores (P=.182). There were significantly more contrast media extravasations with rotator interval approach than posterior approach (P<.05). Both techniques were successful and well tolerated by patients. Posterior injection technique provided a more effective route with decreased extravasation rate and easier approach compared to the rotator interval approach. © 2014.

  12. Indications for reverse total shoulder arthroplasty in rotator cuff disease.

    PubMed

    Drake, Gregory N; O'Connor, Daniel P; Edwards, T Bradley

    2010-06-01

    Reverse total shoulder arthroplasty (RTSA) was introduced to treat rotator cuff tear arthropathy but is now used to treat a variety of problems. Although its use has expanded substantially since the FDA's approval in 2004, the appropriateness in patients with rotator cuff disease is unclear. We review the use of RTSA in patients with rotator cuff disease to (1) describe classification of rotator cuff tear reparability and the concept of a balanced shoulder; (2) explore the theory behind RTSA design relative to rotator cuff arthropathy; (3) discuss the indications and contraindications for RTSA; and (4) review published outcomes of RTSA for rotator cuff arthropathy. We performed a selective review of the literature on the use of RTSA in the treatment of rotator cuff disease. Modern RTSA designs restore deltoid tension and a functional fulcrum to the rotator cuff deficient shoulder, which allows recovery of active shoulder elevation and effectively restores function in short- and medium-term followup studies. In short-term followup the RTSA relieves symptoms and restores function for patients with cuff tear arthropathy and irreparable rotator cuff tears with pseudoparalysis (preserved deltoid contraction but loss of active elevation). Severely impaired deltoid function, an isolated supraspinatus tear, and the presence of full active shoulder elevation with a massive rotator cuff tear and arthritis are contraindications to RTSA. For properly selected patients who have symptomatic and disabling rotator cuff deficiency, RTSA can result in life-changing improvements in pain, motion, function, and patient satisfaction. Level V therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  13. Quilt Block Symmetries

    ERIC Educational Resources Information Center

    Roscoe, Matt B.; Zephyrs, Joe

    2016-01-01

    Geometric transformations have long been topics of middle school mathematics. Generations of middle school students have learned to reflect, rotate, and translate geometric objects. Historically, though, the mathematics of "movement" might have been considered a departure from other more central middle-grades geometric content areas,…

  14. Functional form for plasma velocity in a rapidly rotating tokamak discharge

    DOE PAGES

    Burrell, Keith H.; Chrystal, C. olin

    2014-07-25

    A recently developed technique using charge exchange spectroscopy determines the ion poloidal rotation in tokamak plasmas from the poloidal variation in the toroidal angular rotation speed. The basis for this technique is the functional form for the plasma velocity calculated from the equilibrium equations. The initial development of this technique utilized the functional form determined for conditions where the ion toroidal rotation speed is much smaller than the ion thermal speed. There are cases, however, where the toroidal rotation can be comparable to the ion thermal speed, especially for high atomic number impurities. Furthermore, the present paper extends the previousmore » analysis to this high rotation speed case and demonstrates how to extract the poloidal rotation speed from measurements of the toroidal angular rotation speed at two points on a flux surface.« less

  15. Design of electrostatically levitated micromachined rotational gyroscope based on UV-LIGA technology

    NASA Astrophysics Data System (ADS)

    Cui, Feng; Chen, Wenyuan; Su, Yufeng; Zhang, Weiping; Zhao, Xiaolin

    2004-12-01

    The prevailing micromachined vibratory gyroscope typically has a proof mass connected to the substrate by a mechanical suspension system, which makes it face a tough challenge to achieve tactical or inertial grade performance levels. With a levitated rotor as the proof mass, a micromachined rotational gyroscope will potentially have higher performance than vibratory gyroscope. Besides working as a moment rebalance dual-axis gyroscope, the micromachined rotational gyroscope based on a levitated rotor can simultaneously work as a force balance tri-axis accelerometer. Micromachined rotational gyroscope based on an electrostatically levitated silicon micromachined rotor has been notably developed. In this paper, factors in designing a rotational gyro/accelerometer based on an electrostatically levitated disc-like rotor, including gyroscopic action of micro rotor, methods of stable levitation, micro displacement detection and control, rotation drive and speed control, vacuum packaging and microfabrication, are comprehensively considered. Hence a design of rotational gyro/accelerometer with an electroforming nickel rotor employing low cost UV-LIGA technology is presented. In this design, a wheel-like flat rotor is proposed and its basic dimensions, diameter and thickness, are estimated according to the required loading capability. Finally, its micromachining methods based on UV-LIGA technology and assembly technology are discussed.

  16. Comparison between Conventional MR Arthrograhphy and Abduction and External Rotation MR Arthrography in Revealing Tears of the Antero-Inferior Glenoid Labrum

    PubMed Central

    Choi, Jung-Ah; Suh, Sang-il; Kim, Baek Hyun; Cha, Sang Hoon; Lee, Ki Yeol; Lee, Chang Hee

    2001-01-01

    Objective To compare, in terms of their demonstration of tears of the anterior glenoid labrum, oblique axial MR arthrography obtained with the patient's shoulder in the abduction and external rotation (ABER) position, with conventional axial MR arthrography obtained with the patient's arm in the neutral position. Materials and Methods MR arthrography of the shoulder, including additional oblique axial sequences with the patient in the ABER position, was performed in 30 patients with a clinical history of recurrent anterior shoulder dislocation. The degree of anterior glenoid labral tear or defect was evaluated in both the conventional axial and the ABER position by two radiologists. Decisions were reached by consensus, and a three-point scale was used: grade 1=normal; grade 2=probable tear, diagnosed when subtle increased signal intensity in the labrum was apparent; grade 3=definite tear/defect, when a contrast material-filled gap between the labrum and the glenoid rim or deficient labrum was present. The scores for each imaging sequence were averaged and to compare conventional axial and ABER position scans, Student's t test was performed. Results In 21 (70%) of 30 patients, the same degree of anterior instability was revealed by both imaging sequences. Eight (27%) had a lower grade in the axial position than in the ABER position, while one (3%) had a higher grade in the axial position. Three whose axial scan was grade 1 showed only equivocal evidence of tearing, but their ABER-position scan, in which a contrast material-filled gap between the labrum and the glenoid rim was present, was grade 3. The average grade was 2.5 (SD=0.73) for axial scans and 2.8 (SD=0.46) for the ABER position. The difference between axial and ABER-position scans was statistically significant (p<0.05). Conclusion MR arthrography with the patient's shoulder in the ABER position is more efficient than conventional axial scanning in revealing the degree of tear or defect of the anterior glenoid labrum. When equivocal features are seen at conventional axial MR arthrography, oblique axial imaging in the ABER position is helpful. PMID:11754329

  17. [Pattern of paralysis and reconstructive operations after traumatic brachial plexus lesions].

    PubMed

    Rühmann, O; Schmolke, S; Carls, J; Wirth, C J

    2002-12-01

    The aim of this study was to evaluate persistent patterns of paralysis after traumatic brachial plexus lesions. As a result, consecutive reconstructive operations according to our differential therapy concept are presented. Between 04/1994 and 12/2000 in 104 patients with brachial plexus palsy, the grade of muscle power of the affected upper extremities was evaluated prospectively. The neuromuscular patterns of defect showed, in most cases, insufficient muscle power grades of 0-2 for the deltoid muscle (90%), supraspinatus muscle (82%), infraspinatus muscle (93%), elbow flexors (67% to 77%), hand and finger extensors (69% to 71%), and the abductor and extensors of the thumb (67% to 70%). In corresponding frequency, the following operations were performed between 04/1994 and 06/2002: shoulder arthrodesis (n 26), trapezius transfer (n 80), rotation osteotomy of humerus (n 10), triceps to biceps transposition (n 11), transposition of forearm flexors or extensors/Steindler operation (n 12), latissimus transfer (n 7), pectoralis transfer (n 1), teres major transfer (n 1), transposition of forearm flexors to the tendons of extensor digitorum (n 19) and of the extensor pollicis longus (n 9), and wrist arthrodesis (n 5). On malfunction of muscles following brachial plexus lesions, taking into account the individual neuromuscular defect, passive joint function, and bony deformities, different procedures such as muscle transposition, arthrodesis, and corrective osteotomy can be performed to improve function of the upper extremity.

  18. [The effects of hook plates on the subacromial space--a clinical and MRT study].

    PubMed

    Hackenberger, J; Schmidt, J; Altmann, T

    2004-01-01

    The analysis of middle- and long-term results after treatment of acromioclavicular joint injuries with a hook plate as a temporary implant and a comparison of the results with those described in literature have been made. In a retrospective study we were able to conduct follow-up examinations on 28 out of 39 Tossy III patients (72 %) who received surgical treatment using a hook plate according to Dreithaler. Examinations took place on average 3.0 (1.2-5.6) years after surgery. A special focus of attention was the effect of the hook plate on the subacromial space. Accordingly, physical examination was supplemented by sonography of the shoulder as well as comparative bilateral shoulder MRI. 86 % of our patients expressed satisfaction with the functional outcome of surgery as opposed to 54 % concerning its cosmetic result. In shoulder sonography no patient turned out to have suffered a higher grade rotator cuff lesion, whereas age-related degenerative alterations were found in 46 % of the patients. Instability under load was found in 7 patients (25 %). Among these were 3 with severe instability (11 %). 2 patients (7 %) were found to have a permanent subluxation of the acromioclavicular joint with partial range of motion impairment. All scores monitored (DASH, Taft, Constant-Murley) on average returned good to excellent results. MRI scans displayed no case of higher grade rotator cuff lesion. In accordance with the findings of ultrasound imaging a higher incidence of extraarticular ossification was found as well as, in some cases, arthrosis of the acromioclavicular joint. In our opinion, the hook plate designed by Dreithaler is easy to handle and serves as a qualified implant for temporary stabilisation of the acromioclavicular joint with middle- and long-term good to excellent results.

  19. The severity of the long head biceps tendinopathy in patients with chronic rotator cuff tears: macroscopic versus microscopic results.

    PubMed

    Wu, Po-Ting; Jou, I-Ming; Yang, Cheng-Chang; Lin, Chii-Jeng; Yang, Chyun-Yu; Su, Fong-Chin; Su, Wei-Ren

    2014-08-01

    This study investigated the histopathology of the long head of biceps (LHB) tendon and correlated the findings with the macroscopic appearances of the LHB and the size of rotator cuff tears (RCTs) in patients with chronic RCTs. We compared biopsy specimens from LHBs in 34 patients with chronic RCTs and grossly normal LHBs in 8 patients undergoing shoulder hemiarthroplasty (controls). Duration of preoperative symptoms, the severity of RCTs, and macroscopic appearance of LHBs were recorded, classified, and compared with the histologic grading and apoptosis index of terminal deoxynucleotide transferase-mediated biotin-deoxy uridine triphosphate nick-end labeling (TUNEL) assays of LHBs. In the RCT group, there were 8 partial-thickness tears with 5 macroscopic LHB lesions, 12 full-thickness tears with 8 macroscopic LHB lesions, and 14 massive tears with 13 macroscopic LHB lesions. There were 6 LHB subluxations. However, the macroscopic grading and the symptom duration were not correlated with the severity of the histology. In patients with massive tears, no matter what the macroscopic appearance of the LHB, the proportion of end-stage (grade 4) histologic LHB tendinopathy significantly increased (85.7%, P < .05) compared with patients with other types of RCTs. There was a consistently high incidence of advanced LHB histology (grade 3 or higher) in each classification of RCTs (75.0%-100.0%). The 8 patients in the control group showed milder histopathology (grade 1 or 2). The apoptosis index significantly increased as the tendinopathy progressed (P < .05). The macroscopic pathology of LHB may not fully reflect the severity of tendinopathy, and the coexisting size of RCTs plays a role in the severity of LHB tendinopathy. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  20. The Theory of Propellers I : Determination of the Circulation Function and the Mass Coefficient for Dual-Rotating Propellers

    NASA Technical Reports Server (NTRS)

    Theodorsen, Theodore

    1944-01-01

    Values of the circulation function have been obtained for dual-rotating propellers. Numerical values are given for four, eight, and twelve-blade dual-rotating propellers and for advance ratios from 2 to about 6. In addition, the circulation function has been determine for single-rotating propellers for the higher values of the advance ratio. The mass coefficient, another quantity of significance in propeller theory, has been introduced.

  1. Arthroscopic Subacromial Spacer Implantation in Patients With Massive Irreparable Rotator Cuff Tears: Clinical and Radiographic Results of 39 Retrospectives Cases.

    PubMed

    Deranlot, Julien; Herisson, Olivier; Nourissat, Geoffroy; Zbili, David; Werthel, Jean David; Vigan, Marie; Bruchou, Francois

    2017-09-01

    To evaluate the clinical and radiographic outcome of a biodegradable subacromial spacer in the treatment of massive irreparable rotator cuff tear. Between January 2011 and December 2014, all shoulders with symptomatic massive irreparable rotator cuff tears treated at our institution with arthroscopic implantation of a biodegradable subacromial spacer followed for at least 1 year were included in our series. Patients with osteoarthritis ≥ grade 3 in the Hamada classification were excluded. Outcome measures included pre- and postoperative, range of motion, Constant score, acromiohumeral distance, and Hamada classification on anteroposterior and lateral radiographs. Thirty-nine consecutive shoulders (37 patients) met the inclusion criteria. The mean age of patients was 69.8 (53-84) years. At the last follow-up (mean 32.8 ± 12.4 months), range of motion was significantly increased for all patients in anterior elevation (from 130° to 160°, P = .02), abduction (from 100° to 160°, P = .01), and external rotation (from 30° to 45°, P = .0001). The mean Constant score was also significantly (P < .001) improved from 44.8 (±15.2) preoperatively to 76.0 (±17.1) at the last follow-up. The mean acromiohumeral distance significantly (P = .002) decreased from 8.2 mm (±3.4) to 6.2 mm (±3.1) at the last follow-up. The Hamada score progressed of 1 radiographic stage in 4 shoulders (15%) and progressed of 3 stages in 2 (4%), whereas the other 32 shoulders remained stable. No intra- or postoperative complications were found except for 1 patient who required a revision for spacer migration. Arthroscopic implantation of a subacromial spacer for irreparable rotator cuff tear leads to significant improvement in shoulder function at a minimum of 1 year postoperatively. Level IV, therapeutic case series; treatment study. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Examining the microtexture evolution in a hole-edge punched into 780 MPa grade hot-rolled steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, J.H.; Kim, M.S.

    The deformation behavior in the hole-edge of 780 MPa grade hot-rolled steel during the punching process was investigated via microstructure characterization and computational simulation. Microstructure characterization was conducted to observe the edges of punched holes through the thickness direction, and electron back-scattered diffraction (EBSD) was used to analyze the heterogeneity of the deformation. Finite element analysis (FEA) that could account for a ductile fracture criterion was conducted to simulate the deformation and fracture behaviors of 780 MPa grade hot-rolled steel during the punching process. Calculation of rotation rate fields at the edges of the punched holes during the punching processmore » revealed that metastable orientations in Euler space were confined to specific orientation groups. Rotation-rate fields effectively explained the stability of the initial texture components in the hole-edge region during the punching process. A visco-plastic self-consistent (VPSC) polycrystal model was used to calculate the microtexture evolution in the hole-edge region during the punching process. FEA revealed that the heterogeneous effective strain was closely related to the heterogeneity of the Kernel average misorientation (KAM) distribution in the hole-edge region. A simulation of the deformation microtexture evolution in the hole-edge region using a VPSC model was in good agreement with the experimental results. - Highlights: •We analyzed the microstructure in a hole-edge punched in HR 780HB steel. •Rotation rate fields revealed the stability of the initial texture components. •Heterogeneous effective stain was closely related to the KAM distribution. •VPSC model successfully simulated the deformation microtexture evolution.« less

  3. Diagnostic accuracy of noncontrast MRI for detection of glenohumeral cartilage lesions: a prospective comparison to arthroscopy.

    PubMed

    VanBeek, Corinne; Loeffler, Bryan J; Narzikul, Alexa; Gordon, Victoria; Rasiej, Michael J; Kazam, Jonathan K; Abboud, Joseph A

    2014-07-01

    The purpose of this study was to determine the prevalence of glenohumeral articular cartilage lesions in patients with rotator cuff tendinopathy and to assess the accuracy of noncontrast magnetic resonance imaging (MRI) in detecting these defects compared with the "gold standard" of arthroscopy. Noncontrast MRI studies obtained in 84 consecutive patients undergoing shoulder arthroscopy for rotator cuff tendinopathy (mean age, 54.8 years; range, 17-82 years) were prospectively evaluated for glenohumeral cartilage lesions. Two fellowship-trained, experienced musculoskeletal radiologists were blinded from the arthroscopic findings and independently evaluated the glenoid and humeral head cartilage on 2 separate occasions. At arthroscopy, cartilage lesions of the humeral head were detected in 23 patients (frequency, 27.4%), and glenoid cartilage lesions were found in 20 patients (frequency, 23.8%). For detection of a humeral lesion on MRI, the radiologists' combined accuracy was 78%, sensitivity was 43%, and specificity was 91%. The combined accuracy for detection of glenoid lesions on MRI was 84%, sensitivity was 53%, and specificity was 93%. Combining the readers, low-grade lesions (International Cartilage Repair Society grades 1 and 2) of the glenoid and humerus were read as negative on MRI in 63% and 86% of cases, respectively. Overall accuracy of noncontrast MRI for detection of glenohumeral articular cartilage lesions is good; however, interpretation is reader dependent, and accuracy is significantly reduced for detection of low-grade lesions. On the basis of these findings, we recommend that patients with rotator cuff tendinopathy undergoing arthroscopy be informed that the presence and severity of cartilage lesions may be underestimated on MRI. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  4. Estimation of ligament strains and joint moments in the ankle during a supination sprain injury.

    PubMed

    Wei, Feng; Fong, Daniel Tik-Pui; Chan, Kai-Ming; Haut, Roger C

    2015-01-01

    This study presents the ankle ligament strains and ankle joint moments during an accidental injury event diagnosed as a grade I anterior talofibular ligament (ATaFL) sprain. A male athlete accidentally sprained his ankle while performing a cutting motion in a laboratory setting. The kinematic data were input to a three-dimensional rigid-body foot model for simulation analyses. Maximum strains in 20 ligaments were evaluated in simulations that investigated various combinations of the reported ankle joint motions. Temporal strains in the ATaFL and the calcaneofibular ligament (CaFL) were then compared and the three-dimensional ankle joint moments were evaluated from the model. The ATaFL and CaFL were highly strained when the inversion motion was simulated (10% for ATaFL and 12% for CaFL). These ligament strains were increased significantly when either or both plantarflexion and internal rotation motions were added in a temporal fashion (up to 20% for ATaFL and 16% for CaFL). Interestingly, at the time strain peaked in the ATaFL, the plantarflexion angle was not large but apparently important. This computational simulation study suggested that an inversion moment of approximately 23 N m plus an internal rotation moment of approximately 11 N m and a small plantarflexion moment may have generated a strain of 15-20% in the ATaFL to produce a grade I ligament injury in the athlete's ankle. This injury simulation study exhibited the potentially important roles of plantarflexion and internal rotation, when combined with a large inversion motion, to produce a grade I ATaFL injury in the ankle of this athlete.

  5. Getting Parents Involved.

    ERIC Educational Resources Information Center

    Butts, Vickie; Finch, Patty A.

    1985-01-01

    Describes a parental involvement program in reading, writing, and human education. The project consists of caring for Clifford, a stuffed toy dog, on a rotated basis by first grade students. Books and pet care items accompany Clifford and provide an opportunity for parent and child to work together. (ML)

  6. Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament tension.

    PubMed

    Walde, T A; Bussert, J; Sehmisch, S; Balcarek, P; Stürmer, K M; Walde, H J; Frosch, K H

    2010-12-01

    Femoral malrotation in total knee arthroplasty is correlated to an increased number of revisions. Anatomic landmarks such as Whiteside line, posterior condyle axis and transepicondylar axis are used for determining femoral component rotation. The femoral rotation achieved with the anatomical landmarks is compared to the femoral rotation achieved by a navigated ligament tension-based tibia-first technique. Ninety-three consecutive patients with gonarthritis were prospectively enrolled. Intraoperatively the anatomical landmarks for femoral rotation and the achieved femoral rotation using a navigated tension-based tibia-first technique were determined and stored for further comparison. A pre- and postoperative functional diagram displaying the extension and flexion and varus or valgus positions was also part of the evaluation. Using anatomical landmarks the rotational errors ranged from 12.2° of internal rotation to 15.5° of external rotation from parallel to the tibial resection surface at 90° flexion. A statistical significant improved femoral rotation was achieved using the ligament tension-based method with a rotational error ranged from 3.0° of internal rotation to 2.4° of external rotation. The functional analyses demonstrated statistical significant lower varus/valgus deviations within the flexion range and an improved maximum varus deviation at 90° flexion using the ligament tension-based method. Compared to the anatomical landmarks a balanced, almost parallel flexion gap was achieved using a navigation technique taking the ligament tension of the knee joint into account. As a result the improved femoral rotation was demonstrated by the functional evaluation. Unilateral overloading of the polyethylene inlay and unilateral instability can thus be avoided. Copyright © 2009 Elsevier B.V. All rights reserved.

  7. Passive contribution of the rotator cuff to abduction and joint stability.

    PubMed

    Tétreault, Patrice; Levasseur, Annie; Lin, Jenny C; de Guise, Jacques; Nuño, Natalia; Hagemeister, Nicola

    2011-11-01

    The purpose of this study is to compare shoulder joint biomechanics during abduction with and without intact non-functioning rotator cuff tissue. A cadaver model was devised to simulate the clinical findings seen in patients with a massive cuff tear. Eight full upper limb shoulder specimens were studied. Initially, the rotator cuff tendons were left intact, representing a non-functional rotator cuff, as seen in suprascapular nerve paralysis or in cuff repair with a patch. Subsequently, a massive rotator cuff tear was re-created. Three-dimensional kinematics and force requirements for shoulder abduction were analyzed for each condition using ten abduction cycles in the plane of the scapula. Mediolateral displacements of the glenohumeral rotation center (GHRC) during abduction with an intact non-functioning cuff were minimal, but massive cuff tear resulted in significant lateral displacement of the GHRC (p < 0.013). Similarly, massive cuff tear caused increased superior migration of the GHRC during abduction compared with intact non-functional cuff (p < 0.01). From 5 to 30° of abduction, force requirements were significantly less with an intact non-functioning cuff than with massive cuff tear (p < 0.009). During abduction, an intact but non-functioning rotator cuff resulted in decreased GHRC displacement in two axes as well as lowered the force requirement for abduction from 5 to 30° as compared with the results following a massive rotator cuff tear. This provides insight into the potential biomechanical effect of repairing massive rotator cuff tears with a biological or synthetic "patch," which is a new treatment for massive cuff tear.

  8. How much vertical displacement of the symphysis indicates instability after pelvic injury?

    PubMed

    Golden, Robert D; Kim, Hyunchul; Watson, Jeffrey D; Oliphant, Bryant W; Doro, Christopher; Hsieh, Adam H; Osgood, Greg M; O'Toole, Robert V

    2013-02-01

    Measures of pubic symphyseal widening are used by at least two classification systems as determinants of injury grade. Recent work has challenged the commonly used parameter of 2.5 cm of pubic symphysis as an accurate marker of pelvic injury grade and has suggested a role of rotation in the flexion-extension plane as a determinant of pelvic stability. We investigated pelvic stability in the flexion-extension plane to determine a threshold of rotational displacement of the hemipelvis above which the potential for instability exists. Cadaveric specimens were mounted onto a servohydraulic biaxial testing machine and subjected to a vertically directed flexion moment. Position of hemipelvis was recorded using a three-dimensional motion capture system and video recording. Displacement of the pubic symphysis and changes in length and position of the sacrospinous and sacrotuberous ligaments were recorded. Amount of force applied was measured and recorded. A yield point was determined as the first point at which the force plot exhibited a decrease in force and was correlated to the corresponding displacement. The mean vertical displacement of the pubic symphysis at the yield point was 16 mm (95% confidence interval, 11-22 mm). Mean sacrospinous ligament strain at yield point was 4% (range, 1.0-9.5%). Pelves with vertical rotational symphyseal displacement of less than 11 mm can reasonably be expected to have rotational stability in the flexion-extension plane. Those with displacement of greater than 22 mm can be expected to have lost some integrity regarding resistance to pelvic flexion. These values may allow clinicians to infer pelvic stability from amount of vertical symphyseal displacement.

  9. Rigid rotators. [deriving the time-independent energy states associated with rotational motions of the molecule

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The two-particle, steady-state Schroedinger equation is transformed to center of mass and internuclear distance vector coordinates, leading to the free particle wave equation for the kinetic energy motion of the molecule and a decoupled wave equation for a single particle of reduced mass moving in a spherical potential field. The latter describes the vibrational and rotational energy modes of the diatomic molecule. For fixed internuclear distance, this becomes the equation of rigid rotator motion. The classical partition function for the rotator is derived and compared with the quantum expression. Molecular symmetry effects are developed from the generalized Pauli principle that the steady-state wave function of any system of fundamental particles must be antisymmetric. Nuclear spin and spin quantum functions are introduced and ortho- and para-states of rotators, along with their degeneracies, are defined. Effects of nuclear spin on entropy are deduced. Next, rigid polyatomic rotators are considered and the partition function for this case is derived. The patterns of rotational energy levels for nonlinear molecules are discussed for the spherical symmetric top, for the prolate symmetric top, for the oblate symmetric top, and for the asymmetric top. Finally, the equilibrium energy and specific heat of rigid rotators are derived.

  10. Absence of sex differences in mental rotation performance in autism spectrum disorder.

    PubMed

    Rohde, Melanie S; Georgescu, Alexandra L; Vogeley, Kai; Fimmers, Rolf; Falter-Wagner, Christine M

    2017-08-01

    Mental rotation is one of the most investigated cognitive functions showing consistent sex differences. The 'Extreme Male Brain' hypothesis attributes the cognitive profile of individuals with autism spectrum disorder to an extreme version of the male cognitive profile. Previous investigations focused almost exclusively on males with autism spectrum disorder with only limited implications for affected females. This study is the first testing a sample of 12 female adults with high-functioning autism spectrum disorder compared to 14 males with autism spectrum disorder, 12 typically developing females and 14 typically developing males employing a computerised version of the mental rotation test. Reaction time and accuracy served as dependent variables. Their linear relationship with degree of rotation allows separation of rotational aspects of the task, indicated by slopes of the psychometric function, and non-rotational aspects, indicated by intercepts of the psychometric function. While the typical and expected sex difference for rotational task aspects was corroborated in typically developing individuals, no comparable sex difference was found in autism spectrum disorder individuals. Autism spectrum disorder and typically developing individuals did not differ in mental rotation performance. This finding does not support the extreme male brain hypothesis of autism.

  11. [Arthroscopic double-row reconstruction of high-grade subscapularis tendon tears].

    PubMed

    Plachel, F; Pauly, S; Moroder, P; Scheibel, M

    2018-04-01

    Reconstruction of tendon integrity to maintain glenohumeral joint centration and hence to restore shoulder functional range of motion and to reduce pain. Isolated or combined full-thickness subscapularis tendon tears (≥upper two-thirds of the tendon) without both substantial soft tissue degeneration and cranialization of the humeral head. Chronic tears of the subscapularis tendon with higher grade muscle atrophy, fatty infiltration, and static decentration of the humeral head. After arthroscopic three-sided subscapularis tendon release, two double-loaded suture anchors are placed medially to the humeral footprint. Next to the suture passage, the suture limbs are tied and secured laterally with up to two knotless anchors creating a transosseous-equivalent repair. The affected arm is placed in a shoulder brace with 20° of abduction and slight internal rotation for 6 weeks postoperatively. Rehabilitation protocol including progressive physical therapy from a maximum protection phase to a minimum protection phase is required. Overhead activities are permitted after 6 months. While previous studies have demonstrated superior biomechanical properties and clinical results after double-row compared to single-row and transosseous fixation techniques, further mid- to long-term clinical investigations are needed to confirm these findings.

  12. Functionally Graded Multifunctional Hybrid Composites for Extreme Environments

    DTIC Science & Technology

    2010-02-01

    Develop multifunctional FGHC with multiple layers: a ceramic thermal barrier layer, a graded ceramic /metal composite (GCMeC) layer and a high...AFOSR-MURI Functionally Graded Hybrid Composites Actively Cooled PMC White (UIUC) FGHC Fabrication Team Graded Ceramic Metal Composites (GCMeC...Composites Fabrication and Characterization of Bulk Ceramic MAX Phase and MAX–Metal Composites AFOSR-MURI Functionally Graded Hybrid Composites Mn

  13. Grading of Student's Attainment: Purposes and Functions.

    ERIC Educational Resources Information Center

    Lysne, Anders

    1984-01-01

    Traces the history of grading and discusses the complex problem of evaluation and grading of student achievement. Reviews the various reference measures and notes the type of functions grades are supposed to serve. Cites seven alternatives to traditional grading. Concludes that "grades are the tail that wags the dog." (BRR)

  14. From platelet-rich plasma to the reverse prosthesis: controversies in treating rotator cuff pathology.

    PubMed

    Craig, Edward V; Galatz, Leesa M; Sperling, John W

    2014-01-01

    Rotator cuff pathology and tearing remains a common cause of shoulder pain and disability. Although little controversy and disagreement exists regarding the treatment of small to moderate size tears in good quality tissue without retraction, there is difficulty in agreeing on the ideal treatment of the largest tears, particularly because those tears may be accompanied by widely variable levels of pain and function. Clinical decision making is made more difficult because of the variable presentations observed in patients with a documented full-thickness rotator cuff tear: some have good function and no pain, some have good function and pain, some have poor function and no pain, and some have both poor function and pain. The role of biologics as an adjunct in treating most rotator cuff tears remains unclear, with ongoing exploration of the roles of stem cells, growth factors, and platelet-rich plasma. In patients with unreconstructable tears with marked weakness in external rotation but good elevation, a latissimus transfer may restore rotation. Patches may play a role in partial repairs while serving as both a lattice for healing and a biomechanical anchoring point for sutures. In patients with massive tears and arthritis and in many who have rotator cuff insufficiency, pseudoparalysis, or anterosuperior escape without arthritis, reverse shoulder arthroplasty has led to improvements in pain and strength and revolutionized the treatment of rotator cuff tears.

  15. Light diffraction studies of single muscle fibers as a function of fiber rotation.

    PubMed Central

    Gilliar, W G; Bickel, W S; Bailey, W F

    1984-01-01

    Light diffraction patterns from single glycerinated frog semitendinosus muscle fibers were examined photographically and photoelectrically as a function of diffraction angle and fiber rotation. The total intensity diffraction pattern indicates that the order maxima change both position and intensity periodically as a function of rotation angle. The total diffracted light, light diffracted above and below the zero-order plane, and light diffracted into individual orders gives information about the fiber's longitudinal and rotational structure and its noncylindrical symmetry. Images FIGURE 2 PMID:6611174

  16. Evaluation of an exercise concept focusing on eccentric strength training of the rotator cuff for patients with subacromial impingement syndrome.

    PubMed

    Bernhardsson, Susanne; Klintberg, Ingrid Hultenheim; Wendt, Gunilla Kjellby

    2011-01-01

    To evaluate the effect on pain intensity and function of an exercise concept focusing on specific eccentric strength training of the rotator cuff in patients with subacromial impingement syndrome. Single-subject research design with baseline and treatment phases (AB design). Home-based training programme supervised and supported by visits to physiotherapy clinic. Ten patients, mean (SD) age 54 (8.6) years, symptom duration 12 (9.1) months. Daily eccentric strengthening exercises of the rotator cuff during 12 weeks. Pain intensity, assessed with a visual analogue scale, and function, using the Patient-Specific Functional Scale. Shoulder function evaluated with the Constant score, and shoulder-related quality of life evaluated with the Western Ontario Rotator Cuff Index. Pain intensity decreased significantly in eight of the ten subjects. Function improved significantly in all ten subjects. Constant score increased in nine subjects and Western Ontario Rotator Cuff Index increased in seven subjects. Mean Constant score for the whole group increased significantly from 44 to 69 points (P = 0.008). Mean Western Ontario Rotator Cuff Index increased from 51 to 71% (P = 0.021). A 12-week eccentric strengthening programme targeting the rotator cuff and incorporating scapular control and correct movement pattern can be effective in decreasing pain and increasing function in patients with subacromial impingement syndrome. A randomized controlled trial is necessary to provide stronger evidence of the method.

  17. Adolescents born prematurely with isolated grade 2 haemorrhage in the early 1990s face increased risks of learning challenges.

    PubMed

    Vohr, Betty R; Allan, Walter; Katz, Karol H; Schneider, Karen; Tucker, Richard; Ment, Laura R

    2014-10-01

    To compare the impact of low-grade haemorrhage on neurocognitive function in 16-year-old adolescents born preterm, by grade of intraventricular haemorrhage, and term controls. We evaluated 338 preterm adolescents (birth weight 600-1250 g) for intelligence, executive function and memory tasks. Eleven had grade 3-4 haemorrhage, 44 had grade 2, 31 had grade 1, and 251 had no haemorrhage. Group comparisons were made with 102 term age-matched controls, and regression models used to identify the risk that low-grade haemorrhage posed for cognitive, executive function and memory deficits. Preterm adolescents with grade 2 haemorrhage had higher deficit rates of verbal intelligence, receptive vocabulary, phonemic fluency, cognitive flexibility and phonological fluency than preterm adolescents with grade 1 or no haemorrhage, compared with term controls. After excluding preterm adolescents with both grade 2 haemorrhage and cystic periventricular leukomalacia, those with isolated grade 2 haemorrhage remained at greater risk of cognitive and executive function deficits than term controls and of cognitive deficits than preterm adolescents with no haemorrhage. Our findings suggest that preterm adolescents born in the early 1990s with isolated grade 2 haemorrhage are at increased risk of learning challenges, including cognitive and executive function deficits. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  18. Dinosaur Day!

    ERIC Educational Resources Information Center

    Nakamura, Sandra; Baptiste, H. Prentice

    2006-01-01

    In this article, the authors describe how they capitalized on their first-grade students' love of dinosaurs by hosting a fun-filled Dinosaur Day in their classroom. On Dinosaur Day, students rotated through four dinosaur-related learning stations that integrated science content with art, language arts, math, and history in a fun and time-efficient…

  19. Chinese American and Caucasian American Family Interaction Patterns in Spatial Rotation Puzzle Solutions.

    ERIC Educational Resources Information Center

    Hutsinger, Carol S.; Jose, Paul E.

    1995-01-01

    Examined sociocultural influences on mathematics achievement. First generation Chinese American and Caucasian American mother-father-daughter triads were audiotaped as the fifth- and sixth-grade girls solved a spatial puzzle. Chinese American triads were quieter, more respectful, more serious, and more orderly, whereas Caucasian American triads…

  20. Deficiency in Mental Rotation of Upper and Lower-Limbs in Patients With Multiple Sclerosis and Its Relation With Cognitive Functions.

    PubMed

    Azin, Mahdieh; Zangiabadi, Nasser; Moghadas Tabrizi, Yousef; Iranmanesh, Farhad; Baneshi, Mohammad Reza

    2016-08-01

    Mental rotation is a cognitive motor process which was impaired in different neurologic disorders. We investigated whether there were deficits in response pattern, reaction time and response accuracy rate of mental rotation in multiple sclerosis (MS) patients compared to healthy subjects and whether cognitive dysfunctions in MS patients were correlated with mental rotation deficits. Moreover, we showed whether there was a difference between upper and lower-limbs mental rotation in MS patients. Thirty-five MS patients and 25 healthy subjects performed hand mental rotation (HMR) and foot mental rotation (FMR) tasks. Visual information processing speed, spatial learning and memory ability, and visuospatial processing were assessed by Symbol Digit Modalities Test (SDMT), Brief Visuospatial Memory Test-Revised (BVMT-R), and Judgment of Line Orientation Test (JLO) respectively in MS patients. Reaction time for both hand and foot stimuli increased, and response accuracy rate for hand stimuli decreased in MS patients compared to healthy subjects, but response pattern of mental rotation in MS patients persisted. Similar to healthy subjects, MS patients performed upper-limbs mental rotation more easily than a lower-limbs mental rotation with more speed and response accuracy rate. Reaction time and response accuracy rate were correlated with the mentioned cognitive functions. MS patients made use of the correct response pattern for problem solving of increasing orientation from upright stimuli. Reaction time and response accuracy rate altered in these patients and this alteration might occur along with impairment in motor planning. Subjects' better responding to hand stimuli was due to more familiarity with hand stimuli. The correlation of mental rotation ability with cognitive functions indicates the possible role of cognitive functions in mental rotation.

  1. Functional asymmetry of gait in children and youth with low-grade scoliosis.

    PubMed

    Nowotny-Czupryna, Olga; Nowotny, Janusz; Brzek, Anna; Czupryna, Krzysztof

    2006-04-28

    Background. Compensation for abnormal alignment of body parts in scoliosis may occur above or below the pelvis. This manifests as dislocation of body parts or changes in the angular composition of the lower limbs. Compensation for unbalanced body arrangement through changes in pelvic tilt and lower limb joints are typically reflected in the gait pattern of the person with scoliosis. The aim of our research was to determine whether and how improper body arrangement in the frontal plane is reflected in the gait pattern of children and youth with lower degree scolioses. Material and method. Children and youth with scolioses of varying grade were examined. In addition to photogrammetric body posture examination, three-dimensional gait analysis was performed during particular gait phases. For each examined child the results of this analysis were compared to the posture parameters. Results. Varying signs of gait asymmetry were observed in the whole group of children and youth with scoliosis. The symptoms were connected with both general gait attributes (unisommetry and unisochrony) and further gait markers. The most obvious changes were observed in pelvis rotation during the swing phase and excessive pelvis elevation during the mid-stance phase. These deviations did not correlate significantly with the results of the static examination. Conclusions. The gait asymmetries observed in children and youth with low-grade scoliosis are non-specific, and probably depend on the individual capabilities of each person to compensate for deficiencies.

  2. Simplified model of statistically stationary spacecraft rotation and associated induced gravity environments

    NASA Technical Reports Server (NTRS)

    Fichtl, G. H.; Holland, R. L.

    1978-01-01

    A stochastic model of spacecraft motion was developed based on the assumption that the net torque vector due to crew activity and rocket thruster firings is a statistically stationary Gaussian vector process. The process had zero ensemble mean value, and the components of the torque vector were mutually stochastically independent. The linearized rigid-body equations of motion were used to derive the autospectral density functions of the components of the spacecraft rotation vector. The cross-spectral density functions of the components of the rotation vector vanish for all frequencies so that the components of rotation were mutually stochastically independent. The autospectral and cross-spectral density functions of the induced gravity environment imparted to scientific apparatus rigidly attached to the spacecraft were calculated from the rotation rate spectral density functions via linearized inertial frame to body-fixed principal axis frame transformation formulae. The induced gravity process was a Gaussian one with zero mean value. Transformation formulae were used to rotate the principal axis body-fixed frame to which the rotation rate and induced gravity vector were referred to a body-fixed frame in which the components of the induced gravity vector were stochastically independent. Rice's theory of exceedances was used to calculate expected exceedance rates of the components of the rotation and induced gravity vector processes.

  3. One-Dimensional and Two-Dimensional Analytical Solutions for Functionally Graded Beams with Different Moduli in Tension and Compression

    PubMed Central

    Li, Xue; Dong, Jiao

    2018-01-01

    The material considered in this study not only has a functionally graded characteristic but also exhibits different tensile and compressive moduli of elasticity. One-dimensional and two-dimensional mechanical models for a functionally graded beam with a bimodular effect were established first. By taking the grade function as an exponential expression, the analytical solutions of a bimodular functionally graded beam under pure bending and lateral-force bending were obtained. The regression from a two-dimensional solution to a one-dimensional solution is verified. The physical quantities in a bimodular functionally graded beam are compared with their counterparts in a classical problem and a functionally graded beam without a bimodular effect. The validity of the plane section assumption under pure bending and lateral-force bending is analyzed. Three typical cases that the tensile modulus is greater than, equal to, or less than the compressive modulus are discussed. The result indicates that due to the introduction of the bimodular functionally graded effect of the materials, the maximum tensile and compressive bending stresses may not take place at the bottom and top of the beam. The real location at which the maximum bending stress takes place is determined via the extreme condition for the analytical solution. PMID:29772835

  4. Newton Algorithms for Analytic Rotation: An Implicit Function Approach

    ERIC Educational Resources Information Center

    Boik, Robert J.

    2008-01-01

    In this paper implicit function-based parameterizations for orthogonal and oblique rotation matrices are proposed. The parameterizations are used to construct Newton algorithms for minimizing differentiable rotation criteria applied to "m" factors and "p" variables. The speed of the new algorithms is compared to that of existing algorithms and to…

  5. Platelet rich plasma in arthroscopic rotator cuff repair: a prospective RCT study, 2-year follow-up.

    PubMed

    Randelli, Pietro; Arrigoni, Paolo; Ragone, Vincenza; Aliprandi, Alberto; Cabitza, Paolo

    2011-06-01

    Local application of autologous platelet rich plasma (PRP) improves tendon healing in patients undergoing arthroscopic rotator cuff repair. Prospective, randomized, controlled, double blind study; considering an alpha level of 5%, a power of 80%, 22 patients for group are needed. Fifty-three patients who underwent shoulder arthroscopy for the repair of a complete rotator cuff tear were randomly divided into 2 groups, using a block randomization procedure. A treatment group (N = 26) consisted of those who received an intraoperative application of PRP in combination with an autologous thrombin component. A control group (N = 27) consisted of those who did not receive that treatment. Patients were evaluated with validated outcome scores. A magnetic resonance image (MRI) was performed in all cases at more than 1 year post-op. All patients had the same accelerated rehabilitation protocol. The 2 groups were homogeneous. The pain score in the treatment group was lower than the control group at 3, 7, 14, and 30 days after surgery (P < .05). On the Simple Shoulder Test (SST), University of California (UCLA), and Constant scores, strength in external rotation, as measured by a dynamometer, were significantly higher in the treatment group than the control group at 3 months after surgery (strength in external rotation [SER]: 3 ± 1.6 vs 2.1 ± 1.3 kg; SST: 8.9 ± 2.2 vs 7.1 ± 2.7; UCLA: 26.9 ± 3 vs 24.2 ± 4.9; Constant: 65 ± 9 vs 57.8 ± 11; P < .05). There was no difference between the 2 groups after 6, 12, and 24 months. The follow-up MRI showed no significant difference in the healing rate of the rotator cuff tear. In the subgroup of grade 1 and 2 tears, with less retraction, SER in the PRP group was significant higher at 3, 6, 12, and 24 months postoperative (P < .05). The results of our study showed autologous PRP reduced pain in the first postoperative months. The long-term results of subgroups of grade 1 and 2 tears suggest that PRP positively affected cuff rotator healing. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  6. Functional rotation induced by alternating protonation states in the multidrug transporter AcrB: all-atom molecular dynamics simulations.

    PubMed

    Yamane, Tsutomu; Murakami, Satoshi; Ikeguchi, Mitsunori

    2013-10-29

    The multidrug transporter AcrB actively exports a wide variety of noxious compounds using proton-motive force as an energy source in Gram-negative bacteria. AcrB adopts an asymmetric structure comprising three protomers with different conformations that are sequentially converted during drug export; these cyclic conformational changes during drug export are referred to as functional rotation. To investigate functional rotation driven by proton-motive force, all-atom molecular dynamics simulations were performed. Using different protonation states for the titratable residues in the middle of the transmembrane domain, our simulations revealed the correlation between the specific protonation states and the side-chain configurations. Changing the protonation state for Asp408 induced a spontaneous structural transition, which suggests that the proton translocation stoichiometry may be one proton per functional rotation cycle. Furthermore, our simulations demonstrate that alternating the protonation states in the transmembrane domain induces functional rotation in the porter domain, which is primarily responsible for drug transport.

  7. Dispersion relations of elastic waves in one-dimensional piezoelectric/piezomagnetic phononic crystal with functionally graded interlayers.

    PubMed

    Guo, Xiao; Wei, Peijun; Lan, Man; Li, Li

    2016-08-01

    The effects of functionally graded interlayers on dispersion relations of elastic waves in a one-dimensional piezoelectric/piezomagnetic phononic crystal are studied in this paper. First, the state transfer equation of the functionally graded interlayer is derived from the motion equation by the reduction of order (from second order to first order). The transfer matrix of the functionally graded interlayer is obtained by solving the state transfer equation with the spatial-varying coefficient. Based on the transfer matrixes of the piezoelectric slab, the piezomagnetic slab and the functionally graded interlayers, the total transfer matrix of a single cell is obtained. Further, the Bloch theorem is used to obtain the resultant dispersion equations of in-plane and anti-plane Bloch waves. The dispersion equations are solved numerically and the numerical results are shown graphically. Five kinds of profiles of functionally graded interlayers between a piezoelectric slab and a piezomagnetic slab are considered. It is shown that the functionally graded interlayers have evident influences on the dispersion curves and the band gaps. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Hall effects on unsteady MHD reactive flow of second grade fluid through porous medium in a rotating parallel plate channel

    NASA Astrophysics Data System (ADS)

    Krishna, M. Veera; Swarnalathamma, B. V.

    2017-07-01

    We considered the transient MHD flow of a reactive second grade fluid through porous medium between two infinitely long horizontal parallel plates when one of the plate is set into uniform accelerated motion in the presence of a uniform transverse magnetic field under Arrhenius reaction rate. The governing equations are solved by Laplace transform technique. The effects of the pertinent parameters on the velocity, temperature are discussed in detail. The shear stress and Nusselt number at the plates are also obtained analytically and computationally discussed with reference to governing parameters.

  9. Mathematical Minute: Rotating a Function Graph

    ERIC Educational Resources Information Center

    Bravo, Daniel; Fera, Joseph

    2013-01-01

    Using calculus only, we find the angles you can rotate the graph of a differentiable function about the origin and still obtain a function graph. We then apply the solution to odd and even degree polynomials.

  10. Examining issues of underrepresented minority students in introductory physics

    NASA Astrophysics Data System (ADS)

    Watkins, Jessica Ellen

    In this dissertation we examine several issues related to the retention of under-represented minority students in physics and science. In the first section, we show that in calculus-based introductory physics courses, the gender gap on the FCI is diminished through the use of interactive techniques, but in lower-level introductory courses, the gap persists, similar to reports published at other institutions. We find that under-represented racial minorities perform similar to their peers with comparable academic preparation on conceptual surveys, but their average exam grades and course grades are lower. We also examine student persistence in science majors; finding a significant relationship between pedagogy in an introductory physics course and persistence in science. In the second section, we look at student end-of-semester evaluations and find that female students rate interactive teaching methods a full point lower than their male peers. Looking more deeply at student interview data, we find that female students report more social issues related to the discussions in class and both male and female students cite feeling pressure to obtain the correct answer to clicker questions. Finally, we take a look an often-cited claim for gender differences in STEM participation: cognitive differences explain achievement differences in physics. We examine specifically the role of mental rotations in physics achievement and problem-solving, viewing mental rotations as a tool that students can use on physics problems. We first look at student survey results for lower-level introductory students, finding a low, but significant correlation between performance on a mental rotations test and performance in introductory physics courses. In contrast, we did not find a significant relationship for students in the upper-level introductory course. We also examine student problem-solving interviews to investigate the role of mental rotations on introductory problems.

  11. Optical system components for navigation grade fiber optic gyroscopes

    NASA Astrophysics Data System (ADS)

    Heimann, Marcus; Liesegang, Maximilian; Arndt-Staufenbiel, Norbert; Schröder, Henning; Lang, Klaus-Dieter

    2013-10-01

    Interferometric fiber optic gyroscopes belong to the class of inertial sensors. Due to their high accuracy they are used for absolute position and rotation measurement in manned/unmanned vehicles, e.g. submarines, ground vehicles, aircraft or satellites. The important system components are the light source, the electro optical phase modulator, the optical fiber coil and the photodetector. This paper is focused on approaches to realize a stable light source and fiber coil. Superluminescent diode and erbium doped fiber laser were studied to realize an accurate and stable light source. Therefor the influence of the polarization grade of the source and the effects due to back reflections to the source were studied. During operation thermal working conditions severely affect accuracy and stability of the optical fiber coil, which is the sensor element. Thermal gradients that are applied to the fiber coil have large negative effects on the achievable system accuracy of the optic gyroscope. Therefore a way of calculating and compensating the rotation rate error of a fiber coil due to thermal change is introduced. A simplified 3 dimensional FEM of a quadrupole wound fiber coil is used to determine the build-up of thermal fields in the polarization maintaining fiber due to outside heating sources. The rotation rate error due to these sources is then calculated and compared to measurement data. A simple regression model is used to compensate the rotation rate error with temperature measurement at the outside of the fiber coil. To realize a compact and robust optical package for some of the relevant optical system components an approach based on ion exchanged waveguides in thin glass was developed. This waveguides are used to realize 1x2 and 1x4 splitter with fiber coupling interface or direct photodiode coupling.

  12. Differential Item Functioning by Gender on a Large-Scale Science Performance Assessment: A Comparison across Grade Levels.

    ERIC Educational Resources Information Center

    Holweger, Nancy; Taylor, Grace

    The fifth-grade and eighth-grade science items on a state performance assessment were compared for differential item functioning (DIF) due to gender. The grade 5 sample consisted of 8,539 females and 8,029 males and the grade 8 sample consisted of 7,477 females and 7,891 males. A total of 30 fifth grade items and 26 eighth grade items were…

  13. Relationship between Spatial Abilities, Mental Rotation and Functional Anatomy Learning

    ERIC Educational Resources Information Center

    Guillot, Aymeric; Champely, Stephane; Batier, Christophe; Thiriet, Patrice; Collet, Christian

    2007-01-01

    This study investigated the relationship between visuo-spatial representation, mental rotation (MR) and functional anatomy examination results. A total of 184 students completed the Group Embedded Figures Test (GEFT), Mental Rotation Test (MRT) and Gordon Test of Visual Imagery Control. The time spent on personal assignment was also considered.…

  14. A modified variational method for nonlinear vibration analysis of rotating beams including Coriolis effects

    NASA Astrophysics Data System (ADS)

    Tian, Jiajin; Su, Jinpeng; Zhou, Kai; Hua, Hongxing

    2018-07-01

    This paper presents a general formulation for nonlinear vibration analysis of rotating beams. A modified variational method combined with a multi-segment partitioning technique is employed to derive the free and transient vibration behaviors of the rotating beams. The strain energy and kinetic energy functional are formulated based on the order truncation principle of the fully geometrically nonlinear beam theory. The Coriolis effects as well as nonlinear effects due to the coupling of bending-stretching, bending-twist and twist-stretching are taken into account. The present method relaxes the need to explicitly meet the requirements of the boundary conditions for the admissible functions, and allows the use of any linearly independent, complete basis functions as admissible functions for rotating beams. Moreover, the method is readily used to deal with the nonlinear transient vibration problems for rotating beams subjected to dynamic loads. The accuracy, convergence and efficiency of the proposed method are examined by numerical examples. The influences of Coriolis and centrifugal forces on the vibration behaviors of the beams with various hub radiuses and slenderness ratios and rotating at different angular velocities are also investigated.

  15. The role of axis embedding on rigid rotor decomposition analysis of variational rovibrational wave functions.

    PubMed

    Szidarovszky, Tamás; Fábri, Csaba; Császár, Attila G

    2012-05-07

    Approximate rotational characterization of variational rovibrational wave functions via the rigid rotor decomposition (RRD) protocol is developed for Hamiltonians based on arbitrary sets of internal coordinates and axis embeddings. An efficient and general procedure is given that allows employing the Eckart embedding with arbitrary polyatomic Hamiltonians through a fully numerical approach. RRD tables formed by projecting rotational-vibrational wave functions into products of rigid-rotor basis functions and previously determined vibrational eigenstates yield rigid-rotor labels for rovibrational eigenstates by selecting the largest overlap. Embedding-dependent RRD analyses are performed, up to high energies and rotational excitations, for the H(2) (16)O isotopologue of the water molecule. Irrespective of the embedding chosen, the RRD procedure proves effective in providing unambiguous rotational assignments at low energies and J values. Rotational labeling of rovibrational states of H(2) (16)O proves to be increasingly difficult beyond about 10,000 cm(-1), close to the barrier to linearity of the water molecule. For medium energies and excitations the Eckart embedding yields the largest RRD coefficients, thus providing the largest number of unambiguous rotational labels.

  16. Practice-based learning experience to develop residents as clinical faculty members.

    PubMed

    Slazak, Erin M; Zurick, Gina M

    2009-07-01

    A practice-based learning experience designed to expose postgraduate year 1 (PGY1) and 2 (PGY2) residents to and prepare them for a career as clinical faculty is described. A practice-based learning experience was designed to give PGY1 and PGY2 residents exposure to the responsibilities of a clinical faculty member, integrating clinical practice, preceptor duties, and other academia-related responsibilities. The learning experience is a four-week, elective rotation for PGY1 and PGY2 residents. The rotation is designed to correspond to a four-week advanced pharmacy practice experience (APPE) rotation, allowing the resident to work continuously with the same one or two APPE students for the entire rotation. The resident is required to design and implement a rotation for the students and provide clinical services while integrating students into daily tasks, facilitating topic and patient discussions, evaluating assignments, providing constructive feedback, and assigning a final rotation grade. The resident also attends all academic and committee meetings and teaching obligations with his or her residency director, if applicable. The resident is mentored by the residency director throughout all phases of the rotation and is evaluated using goals and objectives tailored to this experience. The development of a formal, structured rotation to give postgraduate residents experience as a preceptor provided an opportunity for residents to further explore their interests in academia and allowed them to serve as a primary preceptor while being guided and evaluated by a mentor.

  17. Effect of weak rotation on large-scale circulation cessations in turbulent convection.

    PubMed

    Assaf, Michael; Angheluta, Luiza; Goldenfeld, Nigel

    2012-08-17

    We investigate the effect of weak rotation on the large-scale circulation (LSC) of turbulent Rayleigh-Bénard convection, using the theory for cessations in a low-dimensional stochastic model of the flow previously studied. We determine the cessation frequency of the LSC as a function of rotation, and calculate the statistics of the amplitude and azimuthal velocity fluctuations of the LSC as a function of the rotation rate for different Rayleigh numbers. Furthermore, we show that the tails of the reorientation PDF remain unchanged for rotating systems, while the distribution of the LSC amplitude and correspondingly the cessation frequency are strongly affected by rotation. Our results are in close agreement with experimental observations.

  18. "Shapes for Kids!" Life Fitness for Grades 5 through 12

    ERIC Educational Resources Information Center

    Talley, Julie Stiles

    2004-01-01

    This article describes an exercise program for children. "Shapes for Kids," takes the same 30-minute approach at the Curves workout for women. The program is set up using 20 stations, which rotate upper-body work, abdominal exercises, lower-body work, and cardiovascular exercises. Some stations combine more than one component. Children change…

  19. Mechanical and biological properties of the micro-/nano-grain functionally graded hydroxyapatite bioceramics for bone tissue engineering.

    PubMed

    Zhou, Changchun; Deng, Congying; Chen, Xuening; Zhao, Xiufen; Chen, Ying; Fan, Yujiang; Zhang, Xingdong

    2015-08-01

    Functionally graded materials (FGM) open the promising approach for bone tissue repair. In this study, a novel functionally graded hydroxyapatite (HA) bioceramic with micrograin and nanograin structure was fabricated. Its mechanical properties were tailored by composition of micrograin and nanograin. The dynamic mechanical analysis (DMA) indicated that the graded HA ceramics had similar mechanical property compared to natural bones. Their cytocompatibility was evaluated via fluorescent microscopy and MTT colorimetric assay. The viability and proliferation of rabbit bone marrow mesenchymal stem cells (BMSCs) on ceramics indicated that this functionally graded HA ceramic had better cytocompatibility than conventional HA ceramic. This study demonstrated that functionally graded HA ceramics create suitable structures to satisfy both the mechanical and biological requirements of bone tissues. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Do Magnetic Resonance Imaging Characteristics of Full-Thickness Rotator Cuff Tears Correlate With Sleep Disturbance?

    PubMed

    Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S

    2017-11-01

    Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.

  1. Abnormalities of mental rotation of hands associated with speed of information processing and executive function in chronic schizophrenic patients.

    PubMed

    Mazhari, Shahrzad; Moghadas Tabrizi, Yousef

    2014-06-01

    Deficits in mental imagery ability have been reported in patients with schizophrenia. However, there is scarce evidence about the correlation between impairment in mental rotation and other cognitive deficits in the patients. The aim of this study was to assess mental rotation ability, along with other measures of cognitive function in patients with schizophrenia. The performance of 29 patients with schizophrenia was compared with 29 healthy controls. Mental rotation was measured with the Hand Rotation Task, and cognitive functions were measured with the Brief Assessment of Cognition in Schizophrenia (BACS). On Hand Rotation Task, the patients were significantly slower and less accurate compared to controls. Moreover, mental rotation accuracy was significantly correlated with all the BACS domains except verbal memory. In multiple regression analysis, the two BACS subscales, Tower of London and Symbol Coding tasks, were significant predictors and accounted for 41% of the variance in accuracy in the patients. These results support previous findings showing dysfunction of the posterior parietal cortex in schizophrenia, which is involved in general mental rotation, as well as other cognitive processes. © 2014 The Authors. Psychiatry and Clinical Neurosciences © 2014 Japanese Society of Psychiatry and Neurology.

  2. Evaluating Sermons: The Function of Grades in Teaching Preaching

    ERIC Educational Resources Information Center

    Helsel, Carolyn Browning

    2017-01-01

    What are grades doing in a homiletics classroom? This article traces the function of grades through the broader history of the educational system in the United States and then makes suggestions for how grades can be used more effectively in teaching preaching. Beginning in the nineteenth century, teachers used grades to rank and motivate students,…

  3. ALBI versus Child-Pugh grading systems for liver function in patients with hepatocellular carcinoma.

    PubMed

    Na, Seong K; Yim, Sun Y; Suh, Sang J; Jung, Young K; Kim, Ji H; Seo, Yeon S; Yim, Hyung J; Yeon, Jong E; Byun, Kwan S; Um, Soon H

    2018-04-01

    The prognostic performance of the albumin-bilirubin (ALBI) grade in hepatocellular carcinoma (HCC) as an objective method of assessing liver function was investigated. Data from 2099 patients with HCC in Korea were collected and analyzed retrospectively. The discriminative performance of ALBI grade was compared with Child-Pugh (C-P) grade for different stages or treatments. The median follow up duration was 16.2 months (range: 1.0-124.9). The median survival times were 49.7 months for C-P grade A (65.8%), 12.4 months for C-P grade B (25.5%), and 4.2 months for C-P grade C (8.6%) (P < 0.001). The median survival times were 84.2 months for ALBI grade 1 (32.8%), 25.5 months for ALBI grade 2 (53.5%), and 7.7 months for ALBI grade 3 (13.7%) (P < 0.001). In early UICC stages, ALBI grade showed better discriminative performance than C-P grade. In curative treatments, ALBI grade also showed better discriminative performance than C-P grade (Harrell's C: 0.624 (C-P grade) vs 0.667 [ALBI grade]). ALBI grade provided better prognostic performance in survival analysis and better distribution of the grades than C-P grade in HCC, suggesting that ALBI grade could be a good alternative grading system for liver function in patients with HCC. © 2018 Wiley Periodicals, Inc.

  4. A lateralization of function approach to sex differences in spatial ability: a reexamination.

    PubMed

    Rilea, Stacy L

    2008-07-01

    The current study assessed the lateralization of function hypothesis (Rilea, S. L., Roskos-Ewoldsen, B., & Boles, D. (2004). Sex differences in spatial ability: A lateralization of function approach. Brain and Cognition, 56, 332-343) which suggested that it was the interaction of brain organization and the type of spatial task that led to sex differences in spatial ability. A second purpose was to evaluate explanations for their unexpected findings on the mental rotation task. In Experiment 1, participants completed the Water Level, Paper Folding, and mental rotation tasks (using an object-based or self-based perspective), presented bilaterally. Sex differences were only observed on the Water Level Task; a right hemisphere advantage was observed on Water Level and mental rotation tasks. In Experiment 2, a human stick figure or a polygon was mentally rotated. Men outperformed women when rotating polygons, but not when rotating stick figures. Men demonstrated a right hemisphere advantage when rotating polygons; women showed no hemisphere differences for either stimulus. Thus, hemisphere processing, task complexity, and stimulus type may influence performance for men and women across different spatial measures.

  5. A method to deconvolve stellar rotational velocities II. The probability distribution function via Tikhonov regularization

    NASA Astrophysics Data System (ADS)

    Christen, Alejandra; Escarate, Pedro; Curé, Michel; Rial, Diego F.; Cassetti, Julia

    2016-10-01

    Aims: Knowing the distribution of stellar rotational velocities is essential for understanding stellar evolution. Because we measure the projected rotational speed v sin I, we need to solve an ill-posed problem given by a Fredholm integral of the first kind to recover the "true" rotational velocity distribution. Methods: After discretization of the Fredholm integral we apply the Tikhonov regularization method to obtain directly the probability distribution function for stellar rotational velocities. We propose a simple and straightforward procedure to determine the Tikhonov parameter. We applied Monte Carlo simulations to prove that the Tikhonov method is a consistent estimator and asymptotically unbiased. Results: This method is applied to a sample of cluster stars. We obtain confidence intervals using a bootstrap method. Our results are in close agreement with those obtained using the Lucy method for recovering the probability density distribution of rotational velocities. Furthermore, Lucy estimation lies inside our confidence interval. Conclusions: Tikhonov regularization is a highly robust method that deconvolves the rotational velocity probability density function from a sample of v sin I data directly without the need for any convergence criteria.

  6. Gender, ethnicity and smoking affect pain and function in patients with rotator cuff tears.

    PubMed

    Maher, Anthony; Leigh, Warren; Brick, Matt; Young, Simon; Millar, James; Walker, Cameron; Caughey, Michael

    2017-09-01

    This study is a collation of baseline demographic characteristics of those presenting for rotator cuff repair in New Zealand, and exploration of associations with preoperative function and pain. Data were obtained from the New Zealand Rotator Cuff Registry; a multicentre, nationwide prospective cohort of rotator cuff repairs undertaken from 1 March 2009 until 31 December 2010. A total of 1383 patients were included in the study. This required complete demographic information, preoperative Flex-SF (functional score) and pain scores. Following univariate analysis, a multivariate model was used. The average age was 58 years (69% males and 11% smokers). New Zealand Europeans made up 90% and Maori 5%. The average preoperative Flex-SF was significantly lower (poorer function) in those over 65 years, females, smokers and Maori, in the non-dominant patients, using a multivariate model. Average preoperative pain scores were significantly worse (higher scores) in females, Maori, Polynesians, smokers, using a multivariate model. This is the largest reported prospective cohort of patients presenting for rotator cuff surgery. Results can be used to understand the effect of rotator cuff tears on the different patients, for example Maori patients who are under-represented, present younger, with more pain and poorer function. © 2017 Royal Australasian College of Surgeons.

  7. Post-traumatic subtalar osteoarthritis: which grading system should we use?

    PubMed

    de Muinck Keizer, Robert-Jan O; Backes, Manouk; Dingemans, Siem A; Goslings, J Carel; Schepers, Tim

    2016-09-01

    To assess and compare post-traumatic osteoarthritis following intra-articular calcaneal fractures, one must have a reliable grading system that consistently grades the post-traumatic changes of the joint. A reliable grading system aids in the communication between treating physicians and improves the interpretation of research. To date, there is no consensus on what grading system to use in the evaluation of post-traumatic subtalar osteoarthritis. The objective of this study was to determine and compare the inter- and intra-rater reliability of two grading systems for post-traumatic subtalar osteoarthritis. Four observers evaluated 50 calcaneal fractures at least one year after trauma on conventional oblique lateral, internally and externally rotated views, and graded post-traumatic subtalar osteoarthritis using the Kellgren and Lawrence Grading Scale (KLGS) and the Paley Grading System (PGS). Inter- and intra-rater reliability were calculated and compared. The inter-rater reliability showed an intra-class correlation (ICC) of 0.54 (95 % CI 0.40-0.67) for the KLGS and an ICC of 0.41 (95 % CI 0.26 - 0.57) for the PGS. This difference was not statistically significant. The intra-rater reliability showed a mean weighted kappa of 0.62 for both the KLGS and the PGS. There is no statistically significant difference in reliability between the Kellgren and Lawrence Grading System (KLGS) and the Paley Grading System (PGS). The PGS allows for an easy two-step approach making it easy for everyday clinical purposes. For research purposes however, the more detailed and widely used KLGS seems preferable.

  8. Rotor Noise due to Blade-Turbulence Interaction.

    NASA Astrophysics Data System (ADS)

    Ishimaru, Kiyoto

    The time-averaged intensity density function of the acoustic radiation from rotating blades is derived by replacing blades with rotating dipoles. This derivation is done under the following turbulent inflow conditions: turbulent ingestion with no inlet strut wakes, inflow turbulence elongation and contraction with no inlet strut wakes, and inlet strut wakes. Dimensional analysis reveals two non-dimensional parameters which play important roles in generating the blade-passing frequency tone and its multiples. The elongation and contraction of inflow turbulence has a strong effect on the generation of the blade-passing frequency tone and its multiples. Increasing the number of rotor blades widens the peak at the blade-passing frequency and its multiples. Increasing the rotational speed widens the peak under the condition that the non-dimensional parameter involving the rotational speed is fixed. The number of struts and blades should be chosen so that (the least common multiple of them)(.)(rotational speed) is in the cutoff range of Sears' function, in order to minimize the effect of the mean flow deficit on the time averaged intensity density function. The acoustic intensity density function is not necessarily stationary even if the inflow turbulence is homogeneous and isotropic. The time variation of the propagation path due to the rotation should be considered in the computation of the intensity density function; for instance, in the present rotor specification, the rotor radius is about 0.3 m and the rotational speed Mach number is about 0.2.

  9. Inferring probabilistic stellar rotation periods using Gaussian processes

    NASA Astrophysics Data System (ADS)

    Angus, Ruth; Morton, Timothy; Aigrain, Suzanne; Foreman-Mackey, Daniel; Rajpaul, Vinesh

    2018-02-01

    Variability in the light curves of spotted, rotating stars is often non-sinusoidal and quasi-periodic - spots move on the stellar surface and have finite lifetimes, causing stellar flux variations to slowly shift in phase. A strictly periodic sinusoid therefore cannot accurately model a rotationally modulated stellar light curve. Physical models of stellar surfaces have many drawbacks preventing effective inference, such as highly degenerate or high-dimensional parameter spaces. In this work, we test an appropriate effective model: a Gaussian Process with a quasi-periodic covariance kernel function. This highly flexible model allows sampling of the posterior probability density function of the periodic parameter, marginalizing over the other kernel hyperparameters using a Markov Chain Monte Carlo approach. To test the effectiveness of this method, we infer rotation periods from 333 simulated stellar light curves, demonstrating that the Gaussian process method produces periods that are more accurate than both a sine-fitting periodogram and an autocorrelation function method. We also demonstrate that it works well on real data, by inferring rotation periods for 275 Kepler stars with previously measured periods. We provide a table of rotation periods for these and many more, altogether 1102 Kepler objects of interest, and their posterior probability density function samples. Because this method delivers posterior probability density functions, it will enable hierarchical studies involving stellar rotation, particularly those involving population modelling, such as inferring stellar ages, obliquities in exoplanet systems, or characterizing star-planet interactions. The code used to implement this method is available online.

  10. Rotation-robust math symbol recognition and retrieval using outer contours and image subsampling

    NASA Astrophysics Data System (ADS)

    Zhu, Siyu; Hu, Lei; Zanibbi, Richard

    2013-01-01

    This paper presents an unified recognition and retrieval system for isolated offline printed mathematical symbols for the first time. The system is based on nearest neighbor scheme and uses modified Turning Function and Grid Features to calculate the distance between two symbols based on Sum of Squared Difference. An unwrap process and an alignment process are applied to modify Turning Function to deal with the horizontal and vertical shift caused by the changing of staring point and rotation. This modified Turning Function make our system robust against rotation of the symbol image. The system obtains top-1 recognition rate of 96.90% and 47.27% Area Under Curve (AUC) of precision/recall plot on the InftyCDB-3 dataset. Experiment result shows that the system with modified Turning Function performs significantly better than the system with original Turning Function on the rotated InftyCDB-3 dataset.

  11. Functionally Graded Adhesives for Composite Joints

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    Adhesives with functionally graded material properties are being considered for use in adhesively bonded joints to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. An enhanced joint finite element, which uses an analytical formulation to obtain exact shape functions, is used to model the joint. Furthermore, proof of concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint.

  12. A Compact X-Ray System for Macromolecular Crystallography. 5

    NASA Technical Reports Server (NTRS)

    Gubarev, Mikhail; Ciszak, Ewa; Ponomarev, Igor; Joy, Marshall

    2000-01-01

    We describe the design and performance of a high flux x-ray system for macromolecular crystallography that combines a microfocus x-ray generator (40 gm FWHM spot size at a power level of 46.5Watts) and a 5.5 mm focal distance polycapillary optic. The Cu K(sub alpha) X-ray flux produced by this optimized system is 7.0 times above the X-ray flux previously reported. The X-ray flux from the microfocus system is also 3.2 times higher than that produced by the rotating anode generator equipped with a long focal distance graded multilayer monochromator (Green optic; CMF24-48-Cu6) and 30% less than that produced by the rotating anode generator with the newest design of graded multilayer monochromator (Blue optic; CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 Watts, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42,540 reflections collected at ambient temperature from a lysozyme crystal yielded R(sub sym) 5.0% for the data extending to 1.7A, and 4.8% for the complete set of data to 1.85A. The amplitudes of the reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model.

  13. Construction of the Non-Rigid Earth Rotation Series

    NASA Astrophysics Data System (ADS)

    Pashkevich, V. V.

    2007-01-01

    Last years a lot of attempts to derive a high-precision theory of the non-rigid Earth rotation are carried out. For these purposes different transfer functions are used. Usually these transfer functions are applied to the series representing the nutation in the longitude and the obliquity of the rigid Earth rotation with respect to the ecliptic of date. The aim of this investigation is a construction of new high-precision non-rigid Earth rotation series (SN9000), dynamically adequate to the DE404/LE404 ephemeris over 2000 time span years, which are presented as functions of the Euler angles Ψ, θ and φ with respect to the fixed ecliptic plane and equinox J2000.0.

  14. Bringing nursing science to the classroom: a collaborative project.

    PubMed

    Reams, Susan; Bashford, Carol

    2009-01-01

    This project resulted as a collaborative effort on the part of a public school system and nursing faculty. The fifth grade student population utilized in this study focused on the skeletal, muscular, digestive, circulatory, respiratory, and nervous systems as part of their school system's existing science and health curriculum. The intent of the study was to evaluate the impact on student learning outcomes as a result of nursing-focused, science-based, hands-on experiential activities provided by nursing faculty in the public school setting. An assessment tool was created for pretesting and posttesting to evaluate learning outcomes resulting from the intervention. Over a two day period, six classes consisting of 25 to 30 students each were divided into three equal small groups and rotated among three interactive stations. Students explored the normal function of the digestive system, heart, lungs, and skin. Improvement in learning using the pretest and posttest assessment tools were documented.

  15. Low birefringent magneto-optical waveguides fabricated via organic-inorganic sol-gel process

    NASA Astrophysics Data System (ADS)

    Choueikani, F.; Royer, F.; Douadi, S.; Skora, A.; Jamon, D.; Blanc, D.; Siblini, A.

    2009-09-01

    This paper is devoted to the study and the characterization of novel magneto-optical waveguides prepared via organic-inorganic sol-gel process. Thin silica/zirconia films doped with magnetic nanoparticles were coated on glass substrate using dip-coating technique. After annealing, samples were UV-treated. Two different techniques were used to measure their properties: m-lines spectroscopy and free space ellipsometry. Results evidence low refractive index waveguides that combine a low modal birefringence (2×10-4) with a Faraday rotation around 15 °/cm (φ = 0.1%). The low birefringence is obtained with a soft UV treatment and a graded intrinsic anisotropy is evidenced for films thicker than 5 μm. Therefore, we prove that the organic-inorganic sol-gel approach is very promising to realize magneto-optical waveguides with a non-reciprocal functionality such as TE-TM mode conversion.

  16. Career Exploration, Level 1. Career-Centered Curriculum for Vocational Complexes in Mississippi.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Div. of Vocational and Technical Education.

    Spanning grades 7 and 8, the level 1 document focuses on the broad exploration of careers and introduces the student to the world of work through simulated laboratory and real life experiences. Career clusters are reviewed, encouraging exploration of self in relation to academic and vocational education. Students are rotated through six six-week…

  17. Monitoring of visually graded structural lumber

    Treesearch

    David E. Kretschmann; James W. Evans; Linda Brown

    To satisfy the increased demand for forest products, much of the future timber supply is expected to be derived from improved trees grown on managed plantations. This fast-grown resource will tend to be harvested in short-age rotations and will contain higher proportions of juvenile wood compared with wood in current harvests. As a result, current allowable properties...

  18. 40 CFR 1066.310 - Coastdown procedures for heavy-duty vehicles.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... or road must not be excessive (considering factors such as road safety standards and effects on the.... To calculate the force due to grade use Section 11.5 of SAE J2263. (2) You must reach a top speed of... rotational inertia of the wheels and tires. (iii) Calculate the road-load force for each measurement interval...

  19. 40 CFR 1066.310 - Coastdown procedures for heavy-duty vehicles.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... or road must not be excessive (considering factors such as road safety standards and effects on the.... To calculate the force due to grade use Section 11.5 of SAE J2263. (2) You must reach a top speed of... rotational inertia of the wheels and tires. (iii) Calculate the road-load force for each measurement interval...

  20. Long-term changes in soil organic carbon and nitrogen under semiarid tillage and cropping practices

    USDA-ARS?s Scientific Manuscript database

    Understanding long-term changes in soil organic carbon (SOC) and total soil nitrogen (TSN) is important for evaluating C fluxes and optimizing N management. We evaluated long-term SOC and TSN changes under dryland rotations for historical stubble-mulch (HSM) and graded terrace (GT) plots on a clay l...

  1. Assessment of Diastolic Function in Single Ventricle Patients Following the Fontan Procedure

    PubMed Central

    Margossian, Renee; Sleeper, Lynn A.; Pearson, Gail D.; Barker, Piers C.; Mertens, Luc; Quartermain, Michael D.; Su, Jason T.; Shirali, Girish; Chen, Shan; Colan, Steven D.

    2016-01-01

    Objectives Patients with functional single ventricles (FSV) following the Fontan procedure have abnormal cardiac mechanics. We sought to determine factors that influence diastolic function and to describe associations of diastolic function with current clinical status. Methods Echocardiograms were obtained as part of the Pediatric Heart Network Fontan Cross-Sectional Study. Diastolic function grade (DFG) was assessed as normal (grade 0), impaired relaxation (grade 1), pseudonormalization (grade 2), restrictive (grade 3). Studies were also classified dichotomously (restrictive pattern present or absent). Relationships between DFG and pre-Fontan variables (e.g., ventricular morphology, age at Fontan, history of volume-unloading surgery), and current status (e.g., systolic function, valvar regurgitation, exercise performance) were explored. Results DFG was calculable in 326/546 subjects (60%); mean age = 11.7±3.3 years. Overall, 32% of patients had grade 0, 9% grade 1, 37% grade 2, and 22% grade 3. Although there was no association between ventricular morphology and DFG, there was an association between ventricular morphology and E’, which was lowest in those with right ventricular morphology (p<.001); this association remained significant when using z-scores adjusted for age (p=<.001). DFG was associated with achieving maximal effort on exercise testing (p=.004); the majority (64%) of those not achieving maximal effort had DFG 2 or 3.No additional significant associations of DFG with laboratory or clinical measures were identified. Conclusion Assessment of diastolic function by current algorithms results in a high percentage of patients with abnormal DFG, but we found few clinically or statistically significant associations. This may imply a lack of impact of abnormal diastolic function upon clinical outcome in this cohort, or may indicate that the methodology may not be applicable to pediatric FSV patients. PMID:27624592

  2. Barn owls maximize head rotations by a combination of yawing and rolling in functionally diverse regions of the neck.

    PubMed

    Krings, Markus; Nyakatura, John A; Boumans, Mark L L M; Fischer, Martin S; Wagner, Hermann

    2017-07-01

    Owls are known for their outstanding neck mobility: these birds can rotate their heads more than 270°. The anatomical basis of this extraordinary neck rotation ability is not well understood. We used X-ray fluoroscopy of living owls as well as forced neck rotations in dead specimens and computer tomographic (CT) reconstructions to study how the individual cervical joints contribute to head rotation in barn owls (Tyto furcata pratincola). The X-ray data showed the natural posture of the neck, and the reconstructions of the CT-scans provided the shapes of the individual vertebrae. Joint mobility was analyzed in a spherical coordinate system. The rotational capability was described as rotation about the yaw and roll axes. The analyses suggest a functional division of the cervical spine into several regions. Most importantly, an upper region shows high rolling and yawing capabilities. The mobility of the lower, more horizontally oriented joints of the cervical spine is restricted mainly to the roll axis. These rolling movements lead to lateral bending, effectively resulting in a side shift of the head compared with the trunk during large rotations. The joints in the middle of the cervical spine proved to contribute less to head rotation. The analysis of joint mobility demonstrated how owls might maximize horizontal head rotation by a specific and variable combination of yawing and rolling in functionally diverse regions of the neck. © 2017 Anatomical Society.

  3. The science of rotator cuff tears: translating animal models to clinical recommendations using simulation analysis.

    PubMed

    Mannava, Sandeep; Plate, Johannes F; Tuohy, Christopher J; Seyler, Thorsten M; Whitlock, Patrick W; Curl, Walton W; Smith, Thomas L; Saul, Katherine R

    2013-07-01

    The purpose of this article is to review basic science studies using various animal models for rotator cuff research and to describe structural, biomechanical, and functional changes to muscle following rotator cuff tears. The use of computational simulations to translate the findings from animal models to human scale is further detailed. A comprehensive review was performed of the basic science literature describing the use of animal models and simulation analysis to examine muscle function following rotator cuff injury and repair in the ageing population. The findings from various studies of rotator cuff pathology emphasize the importance of preventing permanent muscular changes with detrimental results. In vivo muscle function, electromyography, and passive muscle-tendon unit properties were studied before and after supraspinatus tenotomy in a rodent rotator cuff injury model (acute vs chronic). Then, a series of simulation experiments were conducted using a validated computational human musculoskeletal shoulder model to assess both passive and active tension of rotator cuff repairs based on surgical positioning. Outcomes of rotator cuff repair may be improved by earlier surgical intervention, with lower surgical repair tensions and fewer electromyographic neuromuscular changes. An integrated approach of animal experiments, computer simulation analyses, and clinical studies may allow us to gain a fundamental understanding of the underlying pathology and interpret the results for clinical translation.

  4. Generalized Constitutive-Based Theoretical and Empirical Models for Hot Working Behavior of Functionally Graded Steels

    NASA Astrophysics Data System (ADS)

    Vanini, Seyed Ali Sadough; Abolghasemzadeh, Mohammad; Assadi, Abbas

    2013-07-01

    Functionally graded steels with graded ferritic and austenitic regions including bainite and martensite intermediate layers produced by electroslag remelting have attracted much attention in recent years. In this article, an empirical model based on the Zener-Hollomon (Z-H) constitutive equation with generalized material constants is presented to investigate the effects of temperature and strain rate on the hot working behavior of functionally graded steels. Next, a theoretical model, generalized by strain compensation, is developed for the flow stress estimation of functionally graded steels under hot compression based on the phase mixture rule and boundary layer characteristics. The model is used for different strains and grading configurations. Specifically, the results for αβγMγ steels from empirical and theoretical models showed excellent agreement with those of experiments of other references within acceptable error.

  5. Large isosymmetric reorientation of oxygen octahedra rotation axes in epitaxially strained perovskites.

    PubMed

    Rondinelli, James M; Coh, Sinisa

    2011-06-10

    Using first-principles density functional theory calculations, we discover an anomalously large biaxial strain-induced octahedral rotation axis reorientation in orthorhombic perovskites with tendency towards rhombohedral symmetry. The transition between crystallographically equivalent (isosymmetric) structures with different octahedral rotation magnitudes originates from strong strain-octahedral rotation coupling available to perovskites and the energetic hierarchy among competing octahedral tilt patterns. By elucidating these criteria, we suggest many functional perovskites would exhibit the transition in thin film form, thus offering a new landscape in which to tailor highly anisotropic electronic responses.

  6. The Effect of Glenohumeral Internal-Rotation Deficit on Functional Rotator-Strength Ratio in Adolescent Overhead Athletes.

    PubMed

    Guney, Hande; Harput, Gulcan; Colakoglu, Filiz; Baltaci, Gul

    2016-02-01

    Glenohumeral (GH) internal-rotation deficit (GIRD) and lower eccentric external-rotator (ER) to concentric internal-rotator (IR) strength (ER:IR) ratio have been documented as risk factors for shoulder injuries, but there is no information on whether GIRD has an adverse effect on ER:IR ratio in adolescent overhead athletes. The aim of this study was to investigate the effects of GIRD on functional ER:IR ratio of the adolescent overhead athletes. Cross-sectional study. University research laboratory. 52 adolescent overhead athletes. To determine GIRD, the range of GH IR and ER motion was measured with a digital inclinometer. An isokinetic dynamometer was used to assess eccentric and concentric IR and ER muscle strength of the dominant and nondominant shoulders. One-way ANCOVA where sport type was set as a covariate was used to analyze the difference between athletes with and without GIRD. After standardized examinations of all shoulders, the athletes were divided into 2 groups, shoulders with (n = 27) and without GIRD (n = 25). There was a significant difference between groups in functional ER:IR ratio (P < .001). Athletes with GIRD had lower ER:IR ratio (0.56) than athletes without GIRD (0.83). As GIRD has an adverse effect on functional ratio of the shoulder-rotator muscles, interventions for adolescent overhead athletes should include improving GH-rotation range of motion.

  7. Rotation of a Single Acetylene Molecule on Cu(001) by Tunneling Electrons in STM

    NASA Astrophysics Data System (ADS)

    Shchadilova, Yulia E.; Tikhodeev, Sergei G.; Paulsson, Magnus; Ueba, Hiromu

    2013-11-01

    We study the elementary processes behind one of the pioneering works on scanning tunneling microscope controlled reactions of single molecules [Stipe et al., Phys. Rev. Lett. 81, 1263 (1998)]. Using the Keldysh-Green function approach for the vibrational generation rate in combination with density functional theory calculations to obtain realistic parameters we reproduce the experimental rotation rate of an acetylene molecule on a Cu(100) surface as a function of bias voltage and tunneling current. This combined approach allows us to identify the reaction coordinate mode of the acetylene rotation and its anharmonic coupling with the C-H stretch mode. We show that three different elementary processes, the excitation of C-H stretch, the overtone ladder climbing of the hindered rotational mode, and the combination band excitation together explain the rotation of the acetylene molecule on Cu(100).

  8. Functional status and failed rotator cuff repair predict outcomes after arthroscopic-assisted latissimus dorsi transfer for irreparable massive rotator cuff tears.

    PubMed

    Castricini, Roberto; De Benedetto, Massimo; Familiari, Filippo; De Gori, Marco; De Nardo, Pasquale; Orlando, Nicola; Gasparini, Giorgio; Galasso, Olimpio

    2016-04-01

    Arthroscopic-assisted latissimus dorsi tendon transfer (LDTT) has been recently introduced for treatment of irreparable, posterosuperior massive rotator cuff tears. We sought to evaluate the functional outcomes of this technique and to check for possible outcome predictors. The study reviewed 86 patients (aged 59.8 ± 5.9 years) who underwent an arthroscopic-assisted latissimus dorsi tendon transfer after 36.4 ± 9 months of follow-up. Of these, 14 patients (16.3%) sustained an irreparable massive rotator cuff tear after a failed arthroscopic rotator cuff repair. The Constant and Murley score (CMS) was used to assess patients' functionality preoperatively and at follow-up. As a group, the CMS improved with surgery from 35.5 ± 6.1 to 69.5 ± 12.3 (P < .001). A lower preoperative CMS and a previous failed rotator cuff repair resulted in lower postoperative range of motion (P = .044 and P = .007, respectively) and CMS (P = .042 and P = .018, respectively). A previous rotator cuff repair resulted in lower satisfaction with surgery (P = .009). Gender and age did not affect the clinical outcomes. Our results support the effectiveness of arthroscopic-assisted LDTT in the treatment of patients with an irreparable, posterosuperior massive rotator cuff tears in pain relief, functional recovery, and postoperative satisfaction. Patients with lower preoperative CMS and a history of failed rotator cuff repair have a greater likelihood of having a lower clinical result. However, the favorable values of summary postoperative scores do not exclude these patients as candidates for arthroscopic-assisted LDTT. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Degree of tendon degeneration and stage of rotator cuff disease.

    PubMed

    Jo, Chris Hyunchul; Shin, Won Hyoung; Park, Ji Wan; Shin, Ji Sun; Kim, Ji Eun

    2017-07-01

    While tendon degeneration has been known to be an important cause of rotator cuff disease, few studies have objectively proven the association of tendon degeneration and rotator cuff disease. The purpose of this study was to investigate changes of tendon degeneration with respect to the stage of rotator cuff disease. A total of 48 patients were included in the study: 12 with tendinopathy, 12 with a partial-thickness tear (pRCT), 12 with a full-thickness tear (fRCT), and 12 as the control. A full-thickness supraspinatus tendon sample was harvested en bloc from the middle portion between the lateral edge and the musculotendinous junction of the tendon using a biopsy punch with a diameter of 3 mm. Harvested samples were evaluated using a semi-quantitative grading scale with 7 parameters after haematoxylin and eosin staining. There was no significant difference in age, gender, symptom duration, and Kellgren-Lawrence grade between the groups except for the global fatty degeneration index. All of the seven parameters were significantly different between the groups and could be categorized as follows: early responders (fibre structure and arrangement), gradual responder (rounding of the nuclei), after-tear responders (cellularity, vascularity, and stainability), and late responder (hyalinization). The total degeneration scores were not significantly different between the control (6.08 ± 1.16) and tendinopathy (6.67 ± 1.83) (n.s.). However, the score of pRCT group (10.42 ± 1.31) was greater than that of tendinopathy (P < 0.001), and so was the score of fRCT (12.33 ± 1.15) than that of pRCT (p = 0.009). This study showed that the degeneration of supraspinatus tendon increases as the stage of rotator cuff disease progresses from tendinopathy to pRCT, and then to fRCT. The degree of degeneration of tendinopathy was not different from that of normal but aged tendons, and significant tendon degeneration began from the stage of pRCT. The clinical relevance of the study is that strategies and goals of the treatment for rotator cuff disease should be specific to its stage, in order to prevent disease progression for tendinopathy and pRCT, as well to restore the structural integrity for fRCT. Diagnostic, Level I.

  10. Profile of isokinetic eccentric-to-concentric strength ratios of shoulder rotator muscles in elite female team handball players.

    PubMed

    Andrade, Marilia Dos Santos; Fleury, Anna Maria; de Lira, Claudio Andre Barbosia; Dubas, Joao Paulo; da Silva, Antonio Carlos

    2010-05-01

    The purpose of this study was to establish the isokinetic profile of shoulder rotator muscles strength in female handball players. Twenty-seven handball players performed concentric and eccentric strength tests of both dominant and non-dominant upper limbs on an isokinetic dynamometer. Internal and external rotator muscles peak torque was assessed at 1.05, 3.14, and 5.23 rad . s(-1) in concentric mode and at 3.14 and 5.23 rad . s(-1) in eccentric mode. Concentric balance ratio and functional ratio were obtained. Bi-lateral deficiency was compared. Concentric strength for internal and external rotation was significantly greater for the dominant than for the non-dominant limb for all speeds (P < or = 0.0001). For eccentric actions, internal rotator muscles were stronger in the dominant than the non-dominant limb (P < or = 0.0001) at both speeds. Concentric balance and functional balance ratios did not differ between sides at 3.14 rad . s(-1) (P = 0.1631), but at 5.23 rad . s(-1) the functional balance ratio in the dominant limb was lower than for the non-dominant limb (P = 0.0500). Although the dominant side was stronger than the non-dominant side, balance concentric ratios remained the same, with only the functional strength ratio different at 5.23 rad . s(-1). Our results suggest that concentric strength exercises be used for internal and external rotators on the non-dominant side, and functional exercise that improves eccentric rotation strength for prevention programmes.

  11. The Contribution of Executive Functions to Narrative Writing in Fourth Grade Children

    ERIC Educational Resources Information Center

    Drijbooms, Elise; Groen, Margriet A.; Verhoeven, Ludo

    2015-01-01

    The present study investigated the contribution of executive functions to narrative writing in fourth grade children, and evaluated to what extent executive functions contribute differentially to different levels of narrative composition. The written skills of 102 Dutch children in fourth grade were assessed using a narrative picture-elicitation…

  12. Green's formula and variational principles for cosmic-ray transport with application to rotating and shearing flows

    NASA Technical Reports Server (NTRS)

    Webb, G. M.; Jokipii, J. R.; Morfill, G. E.

    1994-01-01

    Green's theorem and Green's formula for the diffusive cosmic-ray transport equation in relativistic flows are derived. Green's formula gives the solution of the transport equation in terms of the Green's function of the adjoint transport equation, and in terms of distributed sources throughout the region R of interest, plus terms involving the particle intensity and streaming on the boundary. The adjoint transport equation describes the time-reversed particle transport. An Euler-Lagrange variational principle is then obtained for both the mean scattering frame distribution function f, and its adjoint f(dagger). Variations of the variational functional with respect to f(dagger) yield the transport equation, whereas variations of f yield the adjoint transport equation. The variational principle, when combined with Noether's theorem, yields the conservation law associated with Green's theorem. An investigation of the transport equation for steady, azimuthal, rotating flows suggests the introduction of a new independent variable H to replace the comoving frame momentum variable p'. For the case of rigid rotating flows, H is conserved and is shown to be analogous to the Hamiltonian for a bead on a rigidly rotating wire. The variable H corresponds to a balance between the centrifugal force and the particle inertia in the rotating frame. The physical interpretation of H includes a discussion of nonrelativistic and special relativistic rotating flows as well as the cases of aziuthal, differentially rotating flows about Schwarzs-child and Kerr black holes. Green's formula is then applied to the problem of the acceleration of ultra-high-energy cosmic rays by galactic rotation. The model for galactic rotation assumes an angular velocity law Omega = Omega(sub 0)(omega(sub 0)/omega), where omega denotes radial distance from the axis of rotation. Green's functions for the galactic rotation problem are used to investigate the spectrum of accelerated particles arising from monoenergetic and truncated power-law sources. We conclude that it is possible to accelerate particles beyond the knee by galactic rotation, but not in sufficient number to adequately explain the observed spectrum.

  13. The Study of Leukocyte Functions in a Rotating Wall Vessel

    NASA Technical Reports Server (NTRS)

    Trial, JoAnn

    1998-01-01

    The objective of this study was to investigate the behavior of leukocytes under free-fall conditions in a rotating wall vessel. In such a vessel, the tendency of a cell to fall in response to gravity is opposed by the rotation of the vessel and the culture medium within, keeping the cells in suspension without fluid shear. Previous reports indicated that such functions as lymphocyte migration through collagen matrix or monocyte cytokine secretion are altered under these conditions, and these changes correlate with similar functional defects of cultured cells seen during spaceflight.

  14. Reactivity to stress and the cognitive components of math disability in grade 1 children.

    PubMed

    MacKinnon McQuarrie, Maureen A; Siegel, Linda S; Perry, Nancy E; Weinberg, Joanne

    2014-01-01

    This study investigated the relationship among working memory, processing speed, math performance, and reactivity to stress in 83 Grade 1 children. Specifically, 39 children with math disability (MD) were compared to 44 children who are typically achieving (TA) in mathematics. It is the first study to use a physiological index of stress (salivary cortisol levels) to measure children's reactivity while completing tasks that assess the core components of MD: working memory for numbers, working memory for words, digits backward, letter number sequence, digit span forward, processing speed for numbers and words, block rotation, and math tasks. Grade 1 children with MD obtained significantly lower scores on the letter number sequence and quantitative concepts tasks. Higher levels of reactivity significantly predicted poorer performance on the working memory for numbers, working memory for words, and quantitative concepts tasks for Grade 1 children, regardless of math ability. Grade 1 children with MD and higher reactivity had significantly lower scores on the letter number sequence task than the children with MD and low reactivity. The findings suggest that high reactivity impairs performance in working memory and math tasks in Grade 1 children, and young children with high reactivity may benefit from interventions aimed at lowering anxiety in stressful situations, which may improve learning. © Hammill Institute on Disabilities 2012.

  15. Reactivity to Stress and the Cognitive Components of Math Disability in Grade 1 Children

    PubMed Central

    MacKinnon McQuarrie, Maureen A.; Siegel, Linda S.; Perry, Nancy E.; Weinberg, Joanne

    2016-01-01

    This study investigated the relationship among working memory, processing speed, math performance, and reactivity to stress in 83 Grade 1 children. Specifically, 39 children with math disability (MD) were compared to 44 children who are typically achieving (TA) in mathematics. It is the first study to use a physiological index of stress (salivary cortisol levels) to measure children’s reactivity while completing tasks that assess the core components of MD: working memory for numbers, working memory for words, digits backward, letter number sequence, digit span forward, processing speed for numbers and words, block rotation, and math tasks. Grade 1 children with MD obtained significantly lower scores on the letter number sequence and quantitative concepts tasks. Higher levels of reactivity significantly predicted poorer performance on the working memory for numbers, working memory for words, and quantitative concepts tasks for Grade 1 children, regardless of math ability. Grade 1 children with MD and higher reactivity had significantly lower scores on the letter number sequence task than the children with MD and low reactivity. The findings suggest that high reactivity impairs performance in working memory and math tasks in Grade 1 children, and young children with high reactivity may benefit from interventions aimed at lowering anxiety in stressful situations, which may improve learning. PMID:23124381

  16. Assessment of Liver Function in Patients With Hepatocellular Carcinoma: A New Evidence-Based Approach—The ALBI Grade

    PubMed Central

    Johnson, Philip J.; Berhane, Sarah; Kagebayashi, Chiaki; Satomura, Shinji; Teng, Mabel; Reeves, Helen L.; O'Beirne, James; Fox, Richard; Skowronska, Anna; Palmer, Daniel; Yeo, Winnie; Mo, Frankie; Lai, Paul; Iñarrairaegui, Mercedes; Chan, Stephen L.; Sangro, Bruno; Miksad, Rebecca; Tada, Toshifumi; Kumada, Takashi; Toyoda, Hidenori

    2015-01-01

    Purpose Most patients with hepatocellular carcinoma (HCC) have associated chronic liver disease, the severity of which is currently assessed by the Child-Pugh (C-P) grade. In this international collaboration, we identify objective measures of liver function/dysfunction that independently influence survival in patients with HCC and then combine these into a model that could be compared with the conventional C-P grade. Patients and Methods We developed a simple model to assess liver function, based on 1,313 patients with HCC of all stages from Japan, that involved only serum bilirubin and albumin levels. We then tested the model using similar cohorts from other geographical regions (n = 5,097) and other clinical situations (patients undergoing resection [n = 525] or sorafenib treatment for advanced HCC [n = 1,132]). The specificity of the model for liver (dys)function was tested in patients with chronic liver disease but without HCC (n = 501). Results The model, the Albumin-Bilirubin (ALBI) grade, performed at least as well as the C-P grade in all geographic regions. The majority of patients with HCC had C-P grade A disease at presentation, and within this C-P grade, ALBI revealed two classes with clearly different prognoses. Its utility in patients with chronic liver disease alone supported the contention that the ALBI grade was indeed an index of liver (dys)function. Conclusion The ALBI grade offers a simple, evidence-based, objective, and discriminatory method of assessing liver function in HCC that has been extensively tested in an international setting. This new model eliminates the need for subjective variables such as ascites and encephalopathy, a requirement in the conventional C-P grade. PMID:25512453

  17. Disentangling rotational velocity distribution of stars

    NASA Astrophysics Data System (ADS)

    Curé, Michel; Rial, Diego F.; Cassetti, Julia; Christen, Alejandra

    2017-11-01

    Rotational speed is an important physical parameter of stars: knowing the distribution of stellar rotational velocities is essential for understanding stellar evolution. However, rotational speed cannot be measured directly and is instead the convolution between the rotational speed and the sine of the inclination angle vsin(i). The problem itself can be described via a Fredhoml integral of the first kind. A new method (Curé et al. 2014) to deconvolve this inverse problem and obtain the cumulative distribution function for stellar rotational velocities is based on the work of Chandrasekhar & Münch (1950). Another method to obtain the probability distribution function is Tikhonov regularization method (Christen et al. 2016). The proposed methods can be also applied to the mass ratio distribution of extrasolar planets and brown dwarfs (in binary systems, Curé et al. 2015). For stars in a cluster, where all members are gravitationally bounded, the standard assumption that rotational axes are uniform distributed over the sphere is questionable. On the basis of the proposed techniques a simple approach to model this anisotropy of rotational axes has been developed with the possibility to ``disentangling'' simultaneously both the rotational speed distribution and the orientation of rotational axes.

  18. Soil microbial biomass and function are altered by 12 years of crop rotation

    NASA Astrophysics Data System (ADS)

    McDaniel, Marshall D.; Grandy, A. Stuart

    2016-11-01

    Declines in plant diversity will likely reduce soil microbial biomass, alter microbial functions, and threaten the provisioning of soil ecosystem services. We examined whether increasing temporal plant biodiversity in agroecosystems (by rotating crops) can partially reverse these trends and enhance soil microbial biomass and function. We quantified seasonal patterns in soil microbial biomass, respiration rates, extracellular enzyme activity, and catabolic potential three times over one growing season in a 12-year crop rotation study at the W. K. Kellogg Biological Station LTER. Rotation treatments varied from one to five crops in a 3-year rotation cycle, but all soils were sampled under a corn year. We hypothesized that crop diversity would increase microbial biomass, activity, and catabolic evenness (a measure of functional diversity). Inorganic N, the stoichiometry of microbial biomass and dissolved organic C and N varied seasonally, likely reflecting fluctuations in soil resources during the growing season. Soils from biodiverse cropping systems increased microbial biomass C by 28-112 % and N by 18-58 % compared to low-diversity systems. Rotations increased potential C mineralization by as much as 53 %, and potential N mineralization by 72 %, and both were related to substantially higher hydrolase and lower oxidase enzyme activities. The catabolic potential of the soil microbial community showed no, or slightly lower, catabolic evenness in more diverse rotations. However, the catabolic potential indicated that soil microbial communities were functionally distinct, and microbes from monoculture corn preferentially used simple substrates like carboxylic acids, relative to more diverse cropping systems. By isolating plant biodiversity from differences in fertilization and tillage, our study illustrates that crop biodiversity has overarching effects on soil microbial biomass and function that last throughout the growing season. In simplified agricultural systems, relatively small increases in crop diversity can have large impacts on microbial community size and function, with cover crops appearing to facilitate the largest increases.

  19. Understanding the Importance of the Teres Minor for Shoulder Function: Functional Anatomy and Pathology.

    PubMed

    Williams, Matthew D; Edwards, Thomas Bradley; Walch, Gilles

    2018-03-01

    Although the teres minor is often overlooked in a normal shoulder, it becomes a key component in maintaining shoulder function when other rotator cuff tendons fail. The teres minor maintains a balanced glenohumeral joint and changes from an insignificant to the most significant external rotator in the presence of major rotator cuff pathology. The presence or absence of the teres minor provides prognostic information on the outcomes of reverse total shoulder arthroplasty and tendon transfers. Clinical tests include the Patte test, the Neer dropping sign, the external rotation lag sign, and the Hertel drop sign. Advanced imaging of the teres minor can be used for classification using the Walch system. Understanding the function and pathology surrounding the teres minor is paramount in comprehensive management of the patient with shoulder pathology. Appropriate clinical examination and imaging of the teres minor are important for preoperative stratification and postoperative expectations.

  20. Effect of surface tension on the dynamical behavior of bubble in rotating fluids under low gravity environment

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Tsao, Y. D.; Leslie, Fred W.; Hong, B. B.

    1988-01-01

    Time dependent evolutions of the profile of free surface (bubble shapes) for a cylindrical container partially filled with a Newtonian fluid of constant density, rotating about its axis of symmetry, have been studied. Numerical computations of the dynamics of bubble shapes have been carried out with the following situations: (1) linear functions of spin-up and spin-down in low and microgravity environments, (2) linear functions of increasing and decreasing gravity enviroment in high and low rotating cylidner speeds, (3) step functions of spin-up and spin-down in a low gravity environment, and (4) sinusoidal function oscillation of gravity environment in high and low rotating cylinder speeds. The initial condition of bubble profiles was adopted from the steady-state formulations in which the computer algorithms have been developed by Hung and Leslie (1988), and Hung et al. (1988).

  1. Dynamical behavior of surface tension on rotating fluids in low and microgravity environments

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Tsao, Y. D.; Hong, B. B.; Leslie, F. W.

    1989-01-01

    Consideration is given to the time-dependent evolutions of the free surface profile (bubble shapes) of a cylindrical container, partially filled with a Newtonian fluid of constant density, rotating about its axis of symmetry in low and microgravity environments. The dynamics of the bubble shapes are calculated for four cases: linear time-dependent functions of spin-up and spin-down in low and microgravity, linear time-dependent functions of increasing and decreasing gravity at high and low rotating cylinder speeds, time-dependent step functions of spin-up and spin-down in low gravity, and sinusoidal function oscillation of the gravity environment in high and low rotating cylinder speeds. It is shown that the computer algorithms developed by Hung et al. (1988) may be used to simulate the profile of time-dependent bubble shapes under variations of centrifugal, capillary, and gravity forces.

  2. Space Science for Children: All about the Planets [Videotape].

    ERIC Educational Resources Information Center

    1999

    This 23-minute videotape takes children, grades K-4, on a tour of the nine planets of our solar system and explains vital statistics and interesting facts about each. Key terms such as rotation, revolution, and orbit, are explained. A hands-on activity that can be used to demonstrate how Saturn's moons actually create its beautiful rings is also…

  3. Children Learning to Explain Daily Celestial Motion: Understanding Astronomy across Moving Frames of Reference

    ERIC Educational Resources Information Center

    Plummer, Julia D.; Wasko, Kyle D.; Slagle, Cynthia

    2011-01-01

    This study investigated elementary students' explanations for the daily patterns of apparent motion of the Sun, Moon, and stars. Third-grade students were chosen for this study because this age level is at the lower end of when many US standards documents suggest students should learn to use the Earth's rotation to explain daily celestial motion.…

  4. Blown film extrusion of poly(lactic acid) without melt strength enhancers

    Treesearch

    Sonal S. Karkhanis; Nicole M. Stark; Ronald C. Sabo; Laurent M. Matuana

    2017-01-01

    Processing strategies were developed to manufacture poly(lactic acid) (PLA) blown films without melt strength enhancers (MSEs). The effects of processing temperature on PLA’s melt properties (shear and elongational viscosities), PLA grades, and other processing conditions [ratio of take-up roller to extruder’s rotational screw speeds or processing speed ratio (PSR) and...

  5. The Virtual Museum of Minerals and Molecules: Molecular Visualization in a Virtual Hands-On Museum

    ERIC Educational Resources Information Center

    Barak, Phillip; Nater, Edward A.

    2005-01-01

    The Virtual Museum of Minerals and Molecules (VMMM) is a web-based resource presenting interactive, 3-D, research-grade molecular models of more than 150 minerals and molecules of interest to chemical, earth, plant, and environmental sciences. User interactivity with the 3-D display allows models to be rotated, zoomed, and specific regions of…

  6. Circulant Matrices and Affine Equivalence of Monomial Rotation Symmetric Boolean Functions

    DTIC Science & Technology

    2015-01-01

    definitions , including monomial rotation symmetric (MRS) Boolean functions and affine equivalence, and a known result for such quadratic functions...degree of the MRS is, we have a similar result as [40, Theorem 1.1] for n = 4p (p prime), or squarefree integers n, which along with our Theorem 5.2

  7. Determination of hemispheric dominance with mental rotation using functional transcranial Doppler sonography and FMRI.

    PubMed

    Hattemer, Katja; Plate, Annika; Heverhagen, Johannes T; Haag, Anja; Keil, Boris; Klein, Karl Martin; Hermsen, Anke; Oertel, Wolfgang H; Hamer, Hajo M; Rosenow, Felix; Knake, Susanne

    2011-01-01

    the aim of this study was to investigate specific activation patterns and potential gender differences during mental rotation and to investigate whether functional magnetic resonance imaging (fMRI) and functional transcranial Doppler sonography (fTCD) lateralize hemispheric dominance concordantly. regional brain activation and hemispheric dominance during mental rotation (cube perspective test) were investigated in 10 female and 10 male healthy subjects using fMRI and fTCD. significant activation was found in the superior parietal lobe, at the parieto-occipital border, in the middle and superior frontal gyrus bilaterally, and the right inferior frontal gyrus using fMRI. Men showed a stronger lateralization to the right hemisphere during fMRI and a tendency toward stronger right-hemispheric activation during fTCD. Furthermore, more activation in frontal and parieto-occipital regions of the right hemisphere was observed using fMRI. Hemispheric dominance for mental rotation determined by the 2 methods correlated well (P= .008), but did not show concordant results in every single subject. the neural basis of mental rotation depends on a widespread bilateral network. Hemispheric dominance for mental rotation determined by fMRI and fTCD, though correlating well, is not always concordant. Hemispheric lateralization of complex cortical functions such as spatial rotation therefore should be investigated using multimodal imaging approaches, especially if used clinically as a tool for the presurgical evaluation of patients undergoing neurosurgery. Copyright © 2009 by the American Society of Neuroimaging.

  8. Functional but Inefficient Kinesthetic Motor Imagery in Adolescents with Autism Spectrum Disorder.

    PubMed

    Chen, Ya-Ting; Tsou, Kuo-Su; Chen, Hao-Ling; Wong, Ching-Ching; Fan, Yang-Teng; Wu, Chien-Te

    2018-03-01

    Whether action representation in individuals with autism spectrum disorder (ASD) is deficient remains controversial, as previous studies of action observation or imitation report conflicting results. Here we investigated the characteristics of action representation in adolescents with ASD through motor imagery (MI) using a hand rotation and an object rotation task. Comparable with the typically-developing group, the individuals with ASD were able to spontaneously use kinesthetic MI to perform the hand rotation task, as manifested by the significant biomechanical effects. However, the ASD group performed significantly slower only in the hand rotation task, but not in the object rotation task. The findings suggest that the adolescents with ASD showed inefficient but functional kinesthetic MI, implicating that their action representation might be preserved.

  9. The Ottawa panel clinical practice guidelines for the management of knee osteoarthritis. Part one: introduction, and mind-body exercise programs.

    PubMed

    Brosseau, Lucie; Taki, Jade; Desjardins, Brigit; Thevenot, Odette; Fransen, Marlene; Wells, George A; Imoto, Aline Mizusaki; Toupin-April, Karine; Westby, Marie; Gallardo, Inmaculada C Álvarez; Gifford, Wendy; Laferrière, Lucie; Rahman, Prinon; Loew, Laurianne; Angelis, Gino De; Cavallo, Sabrina; Shallwani, Shirin Mehdi; Aburub, Ala'; Bennell, Kim L; Van der Esch, Martin; Simic, Milena; McConnell, Sara; Harmer, Alison; Kenny, Glen P; Paterson, Gail; Regnaux, Jean-Philippe; Lefevre-Colau, Marie-Martine; McLean, Linda

    2017-05-01

    To identify effective mind-body exercise programs and provide clinicians and patients with updated, high-quality recommendations concerning non-traditional land-based exercises for knee osteoarthritis. A systematic search and adapted selection criteria included comparative controlled trials with mind-body exercise programs for patients with knee osteoarthritis. A panel of experts reached consensus on the recommendations using a Delphi survey. A hierarchical alphabetical grading system (A, B, C+, C, D, D+, D-) was used, based on statistical significance ( P < 0.5) and clinical importance (⩾15% improvement). The four high-quality studies identified demonstrated that various mind-body exercise programs are promising for improving the management of knee osteoarthritis. Hatha Yoga demonstrated significant improvement for pain relief (Grade B) and physical function (Grade C+). Tai Chi Qigong demonstrated significant improvement for quality of life (Grade B), pain relief (Grade C+) and physical function (Grade C+). Sun style Tai Chi gave significant improvement for pain relief (Grade B) and physical function (Grade B). Mind-body exercises are promising approaches to reduce pain, as well as to improve physical function and quality of life for individuals with knee osteoarthritis.

  10. The inaccuracy of surface-measured model-derived tibiofemoral kinematics

    PubMed Central

    Li, Kang; Zheng, Liying; Tashman, Scott; Zhang, Xudong

    2014-01-01

    This study assessed the accuracy of surface-measured OpenSim-derived tibiofemoral kinematics in functional activities. Ten subjects with unilateral, isolated grade II PCL deficiency performed level running and stair ascent. A dynamic stereo radiography (DSX) system and a Vicon motion capture system simultaneously measured their knee or lower extremity movement. Surface marker motion data from the Vicon system were used to create subject-specific models in OpenSim and derive the tibiofemoral kinematics. The surface-measured model-derived tibiofemoral kinematics in all 6 degrees of freedom (DOFs) were then compared with those measured by the DSX as the benchmarks. The differences between surface- and DSX-measured tibiofemoral kinematics were found to be substantial: the overall mean (±SD) RMS differences during running were 9.1±3.2°, 2.0 ± 1.2°, 6.4 ± 4.5° for the flexion-extension, abduction-adduction, and internal-external rotations, and 7.1± 3.2mm, 8.8± 3.7mm, and 1.9± 1.2mm for anterior-posterior, proximal-distal, and medial-lateral translations. The differences were more pronounced in the relatively higher speed running than in stair ascent. It was also found that surface-based measures significantly underestimated the mean as well as inter-subject variability of the differences between PCL-injured and intact knees in abduction-adduction, internal-external rotation, and anterior-posterior translation. PMID:22964018

  11. Examination of concomitant glenohumeral pathologies in patients treated arthroscopically for calcific tendinitis of the shoulder and implications for routine diagnostic joint exploration.

    PubMed

    Lang, Gernot; Izadpanah, Kaywan; Kubosch, Eva Johanna; Maier, Dirk; Südkamp, Norbert; Ogon, Peter

    2017-11-21

    Glenohumeral exploration is routinely performed during arthroscopic removal of rotator cuff calcifications in patients with calcific tendinitis of the shoulder (CTS). However, evidence on the prevalence of intraarticular co-pathologies is lacking and the benefit of glenohumeral exploration remains elusive. The aim of the present study was to assess and quantify intraoperative pathologies during arthroscopic removal of rotator cuff calcifications in order to determine whether standardized diagnostic glenohumeral exploration appears justified in CTS patients. One hundred forty five patients undergoing arthroscopic removal of calcific depots (CD) that failed conservative treatment were included in a retrospective cohort study. Radiographic parameters including number/localization of calcifications and acromial types, intraoperative arthroscopic findings such as configuration of glenohumeral ligaments, articular cartilage injuries, and characteristics of calcifications and sonographic parameters (characteristics/localization of calcification) were recorded. One hundred forty five patients were analyzed. All CDs were removed by elimination with a blunt hook probe via "squeeze-and-stir-technique" assessed postoperatively via conventional X-rays. Neither subacromial decompression nor refixation of the rotator cuff were performed in any patient. Prevalence of glenohumeral co-pathologies, such as partial tears of the proximal biceps tendon (2.1%), superior labral tears from anterior to posterior (SLAP) lesions (1.4%), and/or partial rotator cuff tears (0.7%) was low. Most frequently, glenohumeral articular cartilage was either entirely intact (ICRS grade 0 (humeral head/glenoid): 46%/48%) or showed very mild degenerative changes (ICRS grade 1: 30%/26%). Two patients (1.3%) required intraarticular surgical treatment due to a SLAP lesion type III (n = 1) and an intraarticular rupture of CD (n = 1). Routine diagnostic glenohumeral exploration does not appear beneficial in arthroscopic treatment of CTS due to the low prevalence of intraarticular pathologies which most frequently do not require surgical treatment. Exploration of the glenohumeral joint in arthroscopic removal of CD should only be performed in case of founded suspicion of relevant concomitant intraarticular pathologies.

  12. Four-Component Relativistic Density-Functional Theory Calculations of Nuclear Spin-Rotation Constants: Relativistic Effects in p-Block Hydrides.

    PubMed

    Komorovsky, Stanislav; Repisky, Michal; Malkin, Elena; Demissie, Taye B; Ruud, Kenneth

    2015-08-11

    We present an implementation of the nuclear spin-rotation (SR) constants based on the relativistic four-component Dirac-Coulomb Hamiltonian. This formalism has been implemented in the framework of the Hartree-Fock and Kohn-Sham theory, allowing assessment of both pure and hybrid exchange-correlation functionals. In the density-functional theory (DFT) implementation of the response equations, a noncollinear generalized gradient approximation (GGA) has been used. The present approach enforces a restricted kinetic balance condition for the small-component basis at the integral level, leading to very efficient calculations of the property. We apply the methodology to study relativistic effects on the spin-rotation constants by performing calculations on XHn (n = 1-4) for all elements X in the p-block of the periodic table and comparing the effects of relativity on the nuclear SR tensors to that observed for the nuclear magnetic shielding tensors. Correlation effects as described by the density-functional theory are shown to be significant for the spin-rotation constants, whereas the differences between the use of GGA and hybrid density functionals are much smaller. Our calculated relativistic spin-rotation constants at the DFT level of theory are only in fair agreement with available experimental data. It is shown that the scaling of the relativistic effects for the spin-rotation constants (varying between Z(3.8) and Z(4.5)) is as strong as for the chemical shieldings but with a much smaller prefactor.

  13. Posterior Rotator Cuff Strengthening Using Theraband® in a Functional Diagonal Pattern in Collegiate Baseball Pitchers

    PubMed Central

    Page, Phillip A.; Lamberth, John; Abadie, Ben; Boling, Robert; Collins, Robert; Linton, Russell

    1993-01-01

    The deceleration phase of the pitching mechanism requires forceful eccentric contraction of the posterior rotator cuff. Because traditional isotonic strengthening may not be specific to this eccentric pattern, a more effective and functional means of strengthening the posterior rotator cuff is needed. Twelve collegiate baseball pitchers performed a moderate intensity isotonic dumbbell strengthening routine for 6 weeks. Six of the 12 subjects were randomly assigned to an experimental group and placed on a Theraband® Elastic Band strengthening routine in a functional-diagonal pattern to emphasize the eccentric contraction of the posterior rotator cuff, in addition to the isotonic routine. The control group (n = 6) performed only the isotonic exercises. Both groups were evaluated on a KIN-COM® isokinetic dynamometer in a functional diagonal pattern. Pretest and posttest average eccentric force production of the posterior rotator cuff was compared at two speeds, 60 and 180°/s. Data were analyzed with an analysis of covariance at the .05 level with significance at 60°/s. Values at 180°/s, however, were not significant. Eccentric force production at 60°/s increased more during training in the experimental group (+19.8%) than in the control group (-1.6%). There was no difference in the two groups at 180°/s; both decreased (8 to 15%). Theraband was effective at 60°/s in functional eccentric strengthening of the posterior rotator cuff in the pitching shoulder. ImagesFig 1. PMID:16558251

  14. Outcome of lower trapezius transfer to reconstruct massive irreparable posterior-superior rotator cuff tear.

    PubMed

    Elhassan, Bassem T; Wagner, Eric R; Werthel, Jean-David

    2016-08-01

    Management of massive irreparable posterior-superior rotator cuff tear can be very challenging. This study reports the outcome of the lower trapezius transfer to reconstruct massive irreparable posterior-superior rotator cuff tear. Included were 33 patients with an average age of 53 years (range, 31-66 years). All patients had symptomatic massive irreparable rotator cuff tear that failed conservative or prior surgical treatment and underwent reconstruction with lower trapezius transfer prolonged by Achilles tendon allograft. The tear was considered irreparable based on the magnetic resonance imaging finding of ≥2 full-thickness rotator cuff tears associated with shortening and retraction of the tendon to the level of the glenoid and a high grade of fatty infiltration of the muscles. This was confirmed at the time of the surgery. At an average follow-up of 47 months, 32 patients had significant improvement in pain, subjective shoulder value, and Disabilities of the Arm, Shoulder and Hand score and shoulder range of motion, including flexion, 120°; abduction, 90°; and external rotation 50°. One patient, with a body mass index of 36 kg/m(2), required débridement for an infection and then later underwent shoulder fusion. Patients with >60° of preoperative flexion had more significant gains in their range of motion. Shoulder external rotation improved in all patients regardless of the extent of the preoperative loss of motion. Transfer of the lower trapezius prolonged with Achilles tendon allograft to reconstruct massive irreparable posterior-superior rotator cuff tear may lead to good outcome in most patients, specifically for those who have preoperative flexion of >60°. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. A Compact X-Ray System for Macromolecular Crystallography

    NASA Technical Reports Server (NTRS)

    Gubarev, Mikhail; Ciszak, Ewa; Ponomarev, Igor; Gibson, Walter; Joy, Marshall

    2000-01-01

    We describe the design and performance of a high flux x-ray system for a macromolecular crystallography that combines a microfocus x-ray generator (40 micrometer full width at half maximum spot size at a power level of 46.5 W) and a collimating polycapillary optic. The Cu Ka lpha x-ray flux produced by this optimized system through a 500,um diam orifice is 7.0 times greater than the x-ray flux previously reported by Gubarev et al. [M. Gubarev et al., J. Appl. Crystallogr. 33, 882 (2000)]. The x-ray flux from the microfocus system is also 2.6 times higher than that produced by a rotating anode generator equipped with a graded multilayer monochromator (green optic, Osmic Inc. CMF24-48-Cu6) and 40% less than that produced by a rotating anode generator with the newest design of graded multilayer monochromator (blue optic, Osmic, Inc. CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 W, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42 540 reflections collected at ambient temperature from a lysozyme crystal yielded R(sub sym)=5.0% for data extending to 1.70 A, and 4.8% for the complete set of data to 1.85 A. The amplitudes of the observed reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model.

  16. Rotational movement (circling) in normal humans: sex difference and relationship to hand, foot and eye preference.

    PubMed

    Bracha, H S; Seitz, D J; Otemaa, J; Glick, S D

    1987-05-19

    An endogenous asymmetry in striatal dopaminergic function has been identified in rats, and related to spontaneous and drug-induced circling (rotation, turning). We have developed an electronic device for measuring in humans the same kinds of rotational movements observed in rats. Our data indicate that, without being aware of the type of information being obtained, normal men and women rotate preferentially to the left or to the right during a routine day. Women had higher average rates of rotation than men. Males that were consistently right-sided (left-hemisphere dominant) for hand, foot and eye dominance rotated more to the right than to the left, whereas left-hemisphere dominant females rotated more to the left than to the right. Subjects tested on two occasions, 6 weeks apart, exhibited consistent (significantly correlated) rotational preferences--this was much more evident in left-hemisphere dominant than in mixed dominance individuals. In view of similar animal data, the device used in this study may become a useful and objective means for obtaining quantitative information regarding the status of basal ganglia function in humans.

  17. Misalignment Effect Function Measurement for Oblique Rotation Axes: Counterintuitive Predictions and Theoretical Extensions

    NASA Technical Reports Server (NTRS)

    Ellis, Stephen R.; Adelstein, Bernard D.; Yeom, Kiwon

    2013-01-01

    The Misalignment Effect Function (MEF) describes the decrement in manual performance associated with a rotation between operators' visual display frame of reference and that of their manual control. It now has been empirically determined for rotation axes oblique to canonical body axes and is compared with the MEF previously measured for rotations about canonical axes. A targeting rule, called the Secant Rule, based on these earlier measurements is derived from a hypothetical process and shown to describe some of the data from three previous experiments. It explains the motion trajectories determined for rotations less than 65deg in purely kinematic terms without the need to appeal to a mental rotation process. Further analysis of this rule in three dimensions applied to oblique rotation axes leads to a somewhat surprising expectation that the difficulty posed by rotational misalignment should get harder as the required movement is shorter. This prediction is confirmed. Geometry underlying this rule also suggests analytic extensions for predicting more generally the difficulty of making movements in arbitrary directions subject to arbitrary misalignments.

  18. The rotational barrier in ethane: a molecular orbital study.

    PubMed

    Quijano-Quiñones, Ramiro F; Quesadas-Rojas, Mariana; Cuevas, Gabriel; Mena-Rejón, Gonzalo J

    2012-04-20

    The energy change on each Occupied Molecular Orbital as a function of rotation about the C-C bond in ethane was studied using the B3LYP, mPWB95 functional and MP2 methods with different basis sets. Also, the effect of the ZPE on rotational barrier was analyzed. We have found that σ and π energies contribution stabilize a staggered conformation. The σ(s) molecular orbital stabilizes the staggered conformation while the stabilizes the eclipsed conformation and destabilize the staggered conformation. The π(z) and molecular orbitals stabilize both the eclipsed and staggered conformations, which are destabilized by the π(v) and molecular orbitals. The results show that the method of calculation has the effect of changing the behavior of the energy change in each Occupied Molecular Orbital energy as a function of the angle of rotation about the C-C bond in ethane. Finally, we found that if the molecular orbital energy contribution is deleted from the rotational energy, an inversion in conformational preference occurs.

  19. Centrifugal distortion and the ring puckering vibration in the microwave spectrum of 2,3-dihydrofuran

    NASA Astrophysics Data System (ADS)

    Cervellati, R.; Degli Esposti, A.; Lister, D. G.; Lopez, J. C.; Alonso, J. L.

    1986-10-01

    The microwave spectrum of 2,3-dihydrofuran has been reinvestigated and measurements for the ground and first five excited states of the ring puckering vibration have been extended to higher frequencies and rotational quantum numbers in order to study the vibrational dependence of the rotational and centrifugal distortion constants. The ring puckering potential function derived by Green from the far infrared spectrum does not reproduce the vibrational dependence of the rotational constants well. A slightly different potential function is derived which gives a reasonable fit both to the far infrared spectrum and the rotational constants. This changes the barrier to ring inversion from 1.00 kJ mol -1 to 1.12 kJ mol -1. The vibrational dependence of the centrifugal distortion constants is accounted for satisfactorily by the theory developed by Creswell and Mills. An attempt to reproduce the vibrational dependence of the rotational and centrifugal distortion constants using the ring puckering potential function and a simple model for this vibration has very limited success.

  20. Time-dependent dynamical behavior of surface tension on rotating fluids under microgravity environment

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Tsao, Y. D.; Hong, B. B.; Leslie, F. W.

    1988-01-01

    Time dependent evolutions of the profile of free surface (bubble shapes) for a cylindrical container partially filled with a Newtonian fluid of constant density, rotating about its axis of symmetry, have been studied. Numerical computations of the dynamics of bubble shapes have been carried out with the following situations: (1) linear functions of spin-up and spin-down in low and microgravity environments, (2) step functions of spin-up and spin-down in a low gravity environment, and (3) sinusoidal function oscillation of gravity environment in high and low rotating cylinder speeds.

  1. Shoulder functional ratio in elite junior tennis players.

    PubMed

    Saccol, Michele Forgiarini; Gracitelli, Guilherme Conforto; da Silva, Rogério Teixeira; Laurino, Cristiano Frota de Souza; Fleury, Anna Maria; Andrade, Marília dos Santos; da Silva, Antonio Carlos

    2010-02-01

    To evaluate shoulder rotation strength and compare the functional ratio between shoulders of elite junior tennis players. This cross-sectional study evaluated muscular rotation performance of 40 junior tennis players (26 male and 14 female) with an isokinetic dynamometer. Strength variables of external (ER) and internal rotators (IR) in concentric and eccentric modes were considered. For the peak torque functional ratio, the eccentric strength of the ER and the concentric strength of the IR were calculated. All variables related to IR were significantly higher on the dominant compared to the non-dominant side in males and females (p<0.05), but only boys exhibited this dominance effect in ER (p<0.05 and p<0.001). Regarding functional ratios, they were significantly lower for the dominant shoulder (p<0.001) and below 1.00 for both groups, indicating that the eccentric strength of the ER was not greater than the concentric strength of the IR. Elite junior tennis players without shoulder injury have shoulder rotation muscle strength imbalances that alter the normal functional ratio between rotator cuff muscles. Although these differences do not seem to affect the athletic performance, detection and prevention with exercise programs at an early age are recommended. Crown Copyright 2009. Published by Elsevier Ltd. All rights reserved.

  2. The Ottawa panel clinical practice guidelines for the management of knee osteoarthritis. Part two: strengthening exercise programs.

    PubMed

    Brosseau, Lucie; Taki, Jade; Desjardins, Brigit; Thevenot, Odette; Fransen, Marlene; Wells, George A; Mizusaki Imoto, Aline; Toupin-April, Karine; Westby, Marie; Álvarez Gallardo, Inmaculada C; Gifford, Wendy; Laferrière, Lucie; Rahman, Prinon; Loew, Laurianne; De Angelis, Gino; Cavallo, Sabrina; Shallwani, Shirin Mehdi; Aburub, Ala'; Bennell, Kim L; Van der Esch, Martin; Simic, Milena; McConnell, Sara; Harmer, Alison; Kenny, Glen P; Paterson, Gail; Regnaux, Jean-Philippe; Lefevre-Colau, Marie-Martine; McLean, Linda

    2017-05-01

    To identify effective strengthening exercise programs and provide rehabilitation teams and patients with updated, high-quality recommendations concerning traditional land-based exercises for knee osteoarthritis. A systematic search and adapted selection criteria included comparative controlled trials with strengthening exercise programs for patients with knee osteoarthritis. A panel of experts reached consensus on the recommendations using a Delphi survey. A hierarchical alphabetical grading system (A, B, C+, C, D, D+ or D-) was based on statistical significance ( p < 0.5) and clinical importance (⩾15% improvement). The 26 high-quality studies identified demonstrated that various strengthening exercise programs with/without other types of therapeutic exercises are generally effective for improving knee osteoarthritis management within a six-month period. Strengthening exercise programs demonstrated a significant improvement for pain relief (four Grade A, ten Grade B, two Grade C+), physical function (four Grade A, eight Grade B) and quality of life (three Grade B). Strengthening in combination with other types of exercises (coordination, balance, functional) showed a significant improvement in pain relief (three Grade A, 11 Grade B, eight Grade C+), physical function (two Grade A, four Grade B, three Grade C+) and quality of life (one Grade A, one Grade C+). There are a variety of choices for strengthening exercise programs with positive recommendations for healthcare professionals and knee osteoarthritis patients. There is a need to develop combined behavioral and muscle-strengthening strategies to improve long-term maintenance of regular strengthening exercise programs.

  3. Efficacy of exercise therapy in workers with rotator cuff tendinopathy: a systematic review

    PubMed Central

    Desmeules, François; Boudreault, Jennifer; Dionne, Clermont E.; Frémont, Pierre; Lowry, Véronique; MacDermid, Joy C.; Roy, Jean-Sébastien

    2016-01-01

    Objective: To perform a systematic review of randomized controlled trials (RCTs) on the efficacy of therapeutic exercises for workers suffering from rotator cuff (RC) tendinopathy. Methods: A literature search in four bibliographical databases (Pubmed, CINAHL, EMBASE, and PEDro) was conducted from inception up to February 2015. RCTs were included if participants were workers suffering from RC tendinopathy, the outcome measures included work-related outcomes, and at least one of the interventions under study included exercises. The methodological quality of the studies was evaluated with the Cochrane Risk of Bias Assessment tool. Results: The mean methodological score of the ten included studies was 54.4%±17.2%. Types of workers included were often not defined, and work-related outcome measures were heterogeneous and often not validated. Three RCTs of moderate methodological quality concluded that exercises were superior to a placebo or no intervention in terms of function and return-to-work outcomes. No significant difference was found between surgery and exercises based on the results of two studies of low to moderate methodological quality. One study of low methodological quality, comparing a workplace-based exercise program focusing on the participants' work demands to an exercise program delivered in a clinical setting, concluded that the work-based intervention was superior in terms of function and return-to-work outcomes. Conclusion: There is low to moderate-grade evidence that therapeutic exercises provided in a clinical setting are an effective modality to treat workers suffering from RC tendinopathy and to promote return-to-work. Further high quality studies comparing different rehabilitation programs including exercises in different settings with defined workers populations are needed to draw firm conclusions on the optimal program to treat workers. PMID:27488037

  4. Efficacy of exercise therapy in workers with rotator cuff tendinopathy: a systematic review.

    PubMed

    Desmeules, François; Boudreault, Jennifer; Dionne, Clermont E; Frémont, Pierre; Lowry, Véronique; MacDermid, Joy C; Roy, Jean-Sébastien

    2016-09-30

    To perform a systematic review of randomized controlled trials (RCTs) on the efficacy of therapeutic exercises for workers suffering from rotator cuff (RC) tendinopathy. A literature search in four bibliographical databases (Pubmed, CINAHL, EMBASE, and PEDro) was conducted from inception up to February 2015. RCTs were included if participants were workers suffering from RC tendinopathy, the outcome measures included work-related outcomes, and at least one of the interventions under study included exercises. The methodological quality of the studies was evaluated with the Cochrane Risk of Bias Assessment tool. The mean methodological score of the ten included studies was 54.4%±17.2%. Types of workers included were often not defined, and work-related outcome measures were heterogeneous and often not validated. Three RCTs of moderate methodological quality concluded that exercises were superior to a placebo or no intervention in terms of function and return-to-work outcomes. No significant difference was found between surgery and exercises based on the results of two studies of low to moderate methodological quality. One study of low methodological quality, comparing a workplace-based exercise program focusing on the participants' work demands to an exercise program delivered in a clinical setting, concluded that the work-based intervention was superior in terms of function and return-to-work outcomes. There is low to moderate-grade evidence that therapeutic exercises provided in a clinical setting are an effective modality to treat workers suffering from RC tendinopathy and to promote return-to-work. Further high quality studies comparing different rehabilitation programs including exercises in different settings with defined workers populations are needed to draw firm conclusions on the optimal program to treat workers.

  5. Sex-specific lateralization of event-related potential effects during mental rotation of polygons.

    PubMed

    Pellkofer, Julia; Jansen, Petra; Heil, Martin

    2014-08-06

    Mental rotation performance has been found to produce one of the largest sex differences in cognition. Many theories suggest that this effect should be accompanied by a sex difference in functional cerebral asymmetry, but empirical data are more than equivocal probably because of (a) the use of inappropriate stimuli and (b) insufficient power of most neurophysiological studies. Therefore, sex differences in mental rotation of polygons were investigated in 122 adults. Men outperformed women on mental rotation speed (as well as on response time and accuracy). On the basis of the electrophysiological brain correlates of mental rotation, we observed a bilateral brain activity for men, whereas women's brain activity was clearly lateralized toward the left hemisphere if and only if mental rotation was involved. Thus, sex differences in functional cerebral asymmetry can indeed be observed if appropriate stimuli are used in a sufficiently large sample.

  6. Role of viscous friction in the reverse rotation of a disk.

    PubMed

    de Castro, Pablo; Parisio, Fernando

    2014-07-01

    The mechanical response of a circularly driven disk in a dissipative medium is considered. We focus on the role played by viscous friction in the spinning motion of the disk, especially on the effect called reverse rotation, where the intrinsic and orbital rotations are antiparallel. Contrary to what happens in the frictionless case, where steady reverse rotations are possible, we find that this dynamical behavior may exist only as a transient when dissipation is considered. Whether or not reverse rotations in fact occur depends on the initial conditions and on two parameters, one related to dragging, inertia, and driving, the other associated with the geometric configuration of the system. The critical value of this geometric parameter (separating the regions where reverse rotation is possible from those where it is forbidden) as a function of viscosity is well adjusted by a q-exponential function.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dag, Serkan; Yildirim, Bora; Sabuncuoglu, Baris

    The objective of this study is to develop crack growth analysis methods for functionally graded materials (FGMs) subjected to mode I cyclic loading. The study presents finite elements based computational procedures for both two and three dimensional problems to examine fatigue crack growth in functionally graded materials. Developed methods allow the computation of crack length and generation of crack front profile for a graded medium subjected to fluctuating stresses. The results presented for an elliptical crack embedded in a functionally graded medium, illustrate the competing effects of ellipse aspect ratio and material property gradation on the fatigue crack growth behavior.

  8. Functionally graded Ti6Al4V and Inconel 625 by Laser Metal Deposition

    NASA Astrophysics Data System (ADS)

    Pulugurtha, Syamala R.

    The objective of the current work was to fabricate a crack-free functionally graded Ti6Al4V and Inconel 625 thin wall structure by Laser Metal Deposition (LMD). One potential application for the current material system is the ability to fabricate a functionally graded alloy that can be used in a space heat exchanger. The two alloys, Inconel 625 and Ti6Al4V are currently used for aerospace applications. They were chosen as candidates for grading because functionally grading those combines the properties of high strength/weight ratio of Ti6Al4V and high temperature oxidation resistance of Inconel 625 into one multifunctional material for the end application. However, there were challenges associated with the presence of Ni-Ti intermetallic phases (IMPs). The study focused on several critical areas such as (1) understanding microstructural evolution, (2) reducing macroscopic cracking, and (3) reducing mixing between graded layers. Finite element analysis (FEA) was performed to understand the effect of process conditions on multilayer claddings for simplified material systems such as SS316L and Inconel 625 where complex microstructures did not form. The thermo-mechanical models were developed using Abaqus(TM) (and some of them experimentally verified) to predict temperature-gradients; remelt layer depths and residual stresses. Microstructure evolution along the functionally graded Ti6Al4V and Inconel 625 was studied under different processing and grading conditions. Thermodynamic modeling using Factsage (v 6.1) was used to construct phase diagrams and predict the possible equilibrium major/minor phases (verified experimentally by XRD) that may be present along the functionally graded Ti6Al4V and Inconel 625 thin wall structures.

  9. Higher-Order Theory for Functionally Graded Materials

    NASA Technical Reports Server (NTRS)

    Aboudi, Jacob; Pindera, Marek-Jerzy; Arnold, Steven M.

    1999-01-01

    This paper presents the full generalization of the Cartesian coordinate-based higher-order theory for functionally graded materials developed by the authors during the past several years. This theory circumvents the problematic use of the standard micromechanical approach, based on the concept of a representative volume element, commonly employed in the analysis of functionally graded composites by explicitly coupling the local (microstructural) and global (macrostructural) responses. The theoretical framework is based on volumetric averaging of the various field quantities, together with imposition of boundary and interfacial conditions in an average sense between the subvolumes used to characterize the composite's functionally graded microstructure. The generalization outlined herein involves extension of the theoretical framework to enable the analysis of materials characterized by spatially variable microstructures in three directions. Specialization of the generalized theoretical framework to previously published versions of the higher-order theory for materials functionally graded in one and two directions is demonstrated. In the applications part of the paper we summarize the major findings obtained with the one-directional and two-directional versions of the higher-order theory. The results illustrate both the fundamental issues related to the influence of microstructure on microscopic and macroscopic quantities governing the response of composites and the technologically important applications. A major issue addressed herein is the applicability of the classical homogenization schemes in the analysis of functionally graded materials. The technologically important applications illustrate the utility of functionally graded microstructures in tailoring the response of structural components in a variety of applications involving uniform and gradient thermomechanical loading.

  10. The Rotator Cuff Organ: Integrating Developmental Biology, Tissue Engineering, and Surgical Considerations to Treat Chronic Massive Rotator Cuff Tears.

    PubMed

    Rothrauff, Benjamin B; Pauyo, Thierry; Debski, Richard E; Rodosky, Mark W; Tuan, Rocky S; Musahl, Volker

    2017-08-01

    The torn rotator cuff remains a persistent orthopedic challenge, with poor outcomes disproportionately associated with chronic, massive tears. Degenerative changes in the tissues that comprise the rotator cuff organ, including muscle, tendon, and bone, contribute to the poor healing capacity of chronic tears, resulting in poor function and an increased risk for repair failure. Tissue engineering strategies to augment rotator cuff repair have been developed in an effort to improve rotator cuff healing and have focused on three principal aims: (1) immediate mechanical augmentation of the surgical repair, (2) restoration of muscle quality and contractility, and (3) regeneration of native enthesis structure. Work in these areas will be reviewed in sequence, highlighting the relevant pathophysiology, developmental biology, and biomechanics, which must be considered when designing therapeutic applications. While the independent use of these strategies has shown promise, synergistic benefits may emerge from their combined application given the interdependence of the tissues that constitute the rotator cuff organ. Furthermore, controlled mobilization of augmented rotator cuff repairs during postoperative rehabilitation may provide mechanotransductive cues capable of guiding tissue regeneration and restoration of rotator cuff function. Present challenges and future possibilities will be identified, which if realized, may provide solutions to the vexing condition of chronic massive rotator cuff tears.

  11. Aeroelastic Tailoring of a Plate Wing with Functionally Graded Materials

    NASA Technical Reports Server (NTRS)

    Dunning, Peter D.; Stanford, Bret K.; Kim, H. Alicia; Jutte, Christine V.

    2014-01-01

    This work explores the use of functionally graded materials for the aeroelastic tailoring of a metallic cantilevered plate-like wing. Pareto trade-off curves between dynamic stability (flutter) and static aeroelastic stresses are obtained for a variety of grading strategies. A key comparison is between the effectiveness of material grading, geometric grading (i.e., plate thickness variations), and using both simultaneously. The introduction of material grading does, in some cases, improve the aeroelastic performance. This improvement, and the physical mechanism upon which it is based, depends on numerous factors: the two sets of metallic material parameters used for grading, the sweep of the plate, the aspect ratio of the plate, and whether the material is graded continuously or discretely.

  12. Domain General Mediators of the Relation between Kindergarten Number Sense and First-Grade Mathematics Achievement

    PubMed Central

    Hassinger-Das, Brenna; Jordan, Nancy C.; Glutting, Joseph; Irwin, Casey; Dyson, Nancy

    2013-01-01

    Domain general skills that mediate the relation between kindergarten number sense and first-grade mathematics skills were investigated. Participants were 107 children who displayed low number sense in the fall of kindergarten. Controlling for background variables, multiple regression analyses showed that attention problems and executive functioning both were unique predictors of mathematics outcomes. Attention problems were more important for predicting first-grade calculation performance while executive functioning was more important for predicting first-grade performance on applied problems. Moreover, both executive functioning and attention problems were unique partial mediators of the relationship between kindergarten and first-grade mathematics skills. The results provide empirical support for developing interventions that target executive functioning and attention problems in addition to instruction in number skills for kindergartners with initial low number sense. PMID:24237789

  13. Domain-general mediators of the relation between kindergarten number sense and first-grade mathematics achievement.

    PubMed

    Hassinger-Das, Brenna; Jordan, Nancy C; Glutting, Joseph; Irwin, Casey; Dyson, Nancy

    2014-02-01

    Domain-general skills that mediate the relation between kindergarten number sense and first-grade mathematics skills were investigated. Participants were 107 children who displayed low number sense in the fall of kindergarten. Controlling for background variables, multiple regression analyses showed that both attention problems and executive functioning were unique predictors of mathematics outcomes. Attention problems were more important for predicting first-grade calculation performance, whereas executive functioning was more important for predicting first-grade performance on applied problems. Moreover, both executive functioning and attention problems were unique partial mediators of the relationship between kindergarten and first-grade mathematics skills. The results provide empirical support for developing interventions that target executive functioning and attention problems in addition to instruction in number skills for kindergartners with initial low number sense. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Left ventricular rotation and torsion in patients with perimembranous ventricular septal defect.

    PubMed

    Zhuang, Yan; Yong, Yong-hong; Yao, Jing; Ji, Ling; Xu, Di

    2014-03-01

    Assessment of left ventricular (LV) rotation has become an important approach for quantifying LV function. In this study, we sought to analyze LV rotation and twist using speckle tracking imaging (STI) in adult patients with isolated ventricular septal defects. Using STI, the peak rotation and time to peak rotation of 6 segments in basal and apical short-axis were measured, respectively, in 32 patients with ventricular septal defect and 30 healthy subjects as controls. The global rotation of the 6 segments in basal and apical and LV twist versus time profile were drawn, the peak rotation and twist of LV were calculated. All the time to peak rotation/twist were expressed as a percentage of end-systole (end-systole = 100%). Left ventricular ejection fraction was measured by biplane Simpson method. In patients group, the peak rotation of posterior, inferior, and postsept wall in basal was higher(P ≤ 0.05) and LV twist was also higher (P ≤ 0.05) than healthy controls. There were no significant differences between 2 groups in the peak rotation of the other 9 segments and left ventricular ejection fraction. Different from the control group, the time to peak rotation of the 6 segments in basal were delayed and the global rotation of the base was delayed (P ≤ 0.05) in ventricular septal defect group. Left ventricular volume overload due to ventricular septal defect has significant effect on LV rotation and twist, and LV rotation and twist may be a new index predicting LV systolic function. © 2013, Wiley Periodicals, Inc.

  15. Rotator cuff crepitus: could Codman really feel a cuff tear?

    PubMed

    Ponce, Brent A; Kundukulam, Joseph A; Sheppard, Evan D; Determann, Jason R; McGwin, Gerald; Narducci, Carl A; Crowther, Marshall J

    2014-07-01

    The objective of this study was to assess the accuracy of palpating crepitus to diagnose rotator cuff tears. Seventy consecutive consenting patients who presented with shoulder pain and no previous imaging or surgery on the affected shoulder were prospectively enrolled during a 10-month period. A standardized patient history and examination, including the crepitus test, were recorded in addition to obtaining standard radiographs. Additional imaging after initial evaluation was performed with magnetic resonance imaging and interpreted by a musculoskeletal radiologist blinded to the examination findings. Statistical analysis was used to determine sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the crepitus test in the clinical diagnosis of a rotator cuff tear. Sixty-three patients had histories, examinations, and imaging studies available for analysis. The crepitus test had a sensitivity of 67%, specificity of 80%, PPV of 91%, and NPV of 43% for all types of rotator cuff tears. The sensitivity and specificity for full-thickness or high-grade partial tears was 82% and 73%, respectively; the PPV and NPV were 77% and 79%. Increasing age improved accuracy as the presence of crepitus in patients older than 55 years had a sensitivity of 76%, specificity of 100%, PPV of 100%, and NPV of 38%. The crepitus test has a favorable sensitivity, specificity, PPV, and NPV to assess the integrity of the rotator cuff and may be a useful examination in the clinical diagnosis of a rotator cuff tear. Published by Mosby, Inc.

  16. Visual Vestibular Interaction in the Dynamic Visual Acuity Test during Voluntary Head Rotation

    NASA Technical Reports Server (NTRS)

    Lee, Moo Hoon; Durnford, Simon; Crowley, John; Rupert, Angus

    1996-01-01

    Although intact vestibular function is essential in maintaining spatial orientation, no good screening tests of vestibular function are available to the aviation community. High frequency voluntary head rotation was selected as a vestibular stimulus to isolate the vestibulo-ocular reflex (VOR) from visual influence. A dynamic visual acuity test that incorporates voluntary head rotation was evaluated as a potential vestibular function screening tool. Twenty-seven normal subjects performed voluntary sinusoidal head rotation at frequencies from 0.7-4.0 Hz under three different visual conditions: visually-enhanced VOR, normal VOR, and visually suppressed VOR. Standardized Baily-Lovie chart letters were presented on a computer monitor in front of the subject, who then was asked to read the letters while rotating his head horizontally. The electro-oculogram and dynamic visual acuity score were recorded and analyzed. There were no significant differences in gain or phase shift among three visual conditions in the frequency range of 2.8 to 4.0 Hz. The dynamic visual acuity score shifted less than 0.3 logMAR at frequencies under 2.0 Hz. The dynamic visual acuity test at frequencies a round 2.0 Hz can be recommended for evaluating vestibular function.

  17. In Vivo Shoulder Function After Surgical Repair of a Torn Rotator Cuff

    PubMed Central

    Bey, Michael J.; Peltz, Cathryn D.; Ciarelli, Kristin; Kline, Stephanie K.; Divine, George W.; van Holsbeeck, Marnix; Muh, Stephanie; Kolowich, Patricia A.; Lock, Terrence R.; Moutzouros, Vasilios

    2015-01-01

    Background Surgical repair of a torn rotator cuff is based on the belief that repairing the tear is necessary to restore normal glenohumeral joint (GHJ) mechanics and achieve a satisfactory clinical outcome. Hypothesis Dynamic joint function is not completely restored by rotator cuff repair, thus compromising shoulder function and potentially leading to long-term disability. Study Design Controlled laboratory study and Case series; Level of evidence, 4. Methods Twenty-one rotator cuff patients and 35 control participants enrolled in the study. Biplane radiographic images were acquired bilaterally from each patient during coronal-plane abduction. Rotator cuff patients were tested at 3, 12, and 24 months after repair of a supraspinatus tendon tear. Control participants were tested once. Glenohumeral joint kinematics and joint contact patterns were accurately determined from the biplane radiographic images. Isometric shoulder strength and patient-reported outcomes were measured at each time point. Ultrasound imaging assessed rotator cuff integrity at 24 months after surgery. Results Twenty of 21 rotator cuff repairs appeared intact at 24 months after surgery. The humerus of the patients’ repaired shoulder was positioned more superiorly on the glenoid than both the patients’ contralateral shoulder and the dominant shoulder of control participants. Patient-reported outcomes improved significantly over time. Shoulder strength also increased over time, although strength deficits persisted at 24 months for most patients. Changes over time in GHJ mechanics were not detected for either the rotator cuff patients’ repaired or contralateral shoulders. Clinical outcome was associated with shoulder strength but not GHJ mechanics. Conclusion Surgical repair of an isolated supraspinatus tear may be sufficient to keep the torn rotator cuff intact and achieve satisfactory patient-reported outcomes, but GHJ mechanics and shoulder strength are not fully restored with current repair techniques. Clinical Relevance The study suggests that current surgical repair techniques may be effective for reducing pain but have not yet been optimized for restoring long-term shoulder function. PMID:21737834

  18. The association between menarche, intensity of training and passive joint ROM in young pre-professional female dancers: A longitudinal follow-up study.

    PubMed

    Nili, Steinberg; Shay, Tenenbaum; Myriam, Stern; Aviva, Zeev; Itzhak, Siev-Ner

    2018-05-05

    To determine the association between the status of menarche (yes/no), the intensity of training and the potential to improve passive joint range of motion (ROM) over a 12-month period of dance training. Prospective cohort study. Dance studio. Fifty-nine female dancers aged 12.8 ± 0.5. The dancers were asked about their dance intensity and screened for anthropometric parameters and passive joint ROM in Grades 7 and 8. Along the 12 months of dance training, we found significantly increased ankle-foot en-pointe, hip abduction, and hip external rotation (ER); significantly decreased hip internal rotation (IR); and significant increased hip ER:IR ratio. In Grade 7, 26 dancers (44.1%) reached menarche (Yes menarche); in Grade 8 an additional 23 dancers (39.0%) reached menarche (No/Yes menarche); and 10 dancers (16.9%) had not reached menarche (No menarche). MANOVA (mixed models) with repeated measures to compare joint ROM between the three menarche groups (Yes; No/Yes; No), with h/week dance practice as a co-variant, showed that hip ER, ankle-foot en-pointe, and ER:IR were significantly correlated with h/week in all three menarche groups. Most passive joint ROM can be improved over 12 months of dancing around the age onset of menarche. H/week of dance practice is a main factor contributing to improved hip ER, ankle-foot en-pointe and ER/IR ratio. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. An efficient algorithm for the retarded time equation for noise from rotating sources

    NASA Astrophysics Data System (ADS)

    Loiodice, S.; Drikakis, D.; Kokkalis, A.

    2018-01-01

    This study concerns modelling of noise emanating from rotating sources such as helicopter rotors. We present an accurate and efficient algorithm for the solution of the retarded time equation, which can be used both in subsonic and supersonic flow regimes. A novel approach for the search of the roots of the retarded time function was developed based on considerations of the kinematics of rotating sources and of the bifurcation analysis of the retarded time function. It is shown that the proposed algorithm is faster than the classical Newton and Brent methods, especially in the presence of sources rotating supersonically.

  20. Masks For Deposition Of Aspherical Optical Surfaces

    NASA Technical Reports Server (NTRS)

    Rogers, John R.; Martin, John D.

    1992-01-01

    Masks of improved design developed for use in fabrication of aspherical, rotationally symmetrical surfaces of mirrors, lenses, and lens molds by evaporative deposition onto rotating substrates. In deposition chamber, source and mask aligned with axis of rotation of substrate. Mask shadows source of rotating substrate. Azimuthal opening (as function of radius) in mask proportional to desired thickness (as function of radius) to which material deposited on substrate. Combination of improved masks and modern coating chambers provides optical surfaces comparable or superior to those produced by conventional polishing, computer-controlled polishing, replication from polished molds, and diamond turning, at less cost in material, labor, and capital expense.

  1. Quantum mechanics in rotating-radio-frequency traps and Penning traps with a quadrupole rotating field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abe, K.; Hasegawa, T.

    2010-03-15

    Quantum-mechanical analysis of ion motion in a rotating-radio-frequency (rrf) trap or in a Penning trap with a quadrupole rotating field is carried out. Rrf traps were introduced by Hasegawa and Bollinger [Phys. Rev. A 72, 043404 (2005)]. The classical motion of a single ion in this trap is described by only trigonometric functions, whereas in the conventional linear radio-frequency (rf) traps it is by the Mathieu functions. Because of the simple classical motion in the rrf trap, it is expected that the quantum-mechanical analysis of the rrf traps is also simple compared to that of the linear rf traps. Themore » analysis of Penning traps with a quadrupole rotating field is also possible in a way similar to the rrf traps. As a result, the Hamiltonian in these traps is the same as the two-dimensional harmonic oscillator, and energy levels and wave functions are derived as exact results. In these traps, it is found that one of the vibrational modes in the rotating frame can have negative energy levels, which means that the zero-quantum-number state (''ground'' state) is the highest energy state.« less

  2. Balance Function Disorders

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Researchers at the Balance Function Laboratory and Clinic at the Minneapolis (MN) Neuroscience Institute on the Abbot Northwestern Hospital Campus are using a rotational chair (technically a "sinusoidal harmonic acceleration system") originally developed by NASA to investigate vestibular (inner ear) function in weightlessness to diagnose and treat patients with balance function disorders. Manufactured by ICS Medical Corporation, Schaumberg, IL, the chair system turns a patient and monitors his or her responses to rotational stimulation.

  3. Effect of rotation speed and welding speed on Friction Stir Welding of AA1100 Aluminium alloy

    NASA Astrophysics Data System (ADS)

    Raja, P.; Bojanampati, S.; Karthikeyan, R.; Ganithi, R.

    2018-04-01

    Aluminum AA1100 is the most widely used grade of Aluminium due to its excellent corrosion resistance, high ductility and reflective finish, the selected material was welded with Friction Stir Welding (FSW) process on a CNC machine, using a combination of different tool rotation speed (1500 rpm, 2500 rpm, 3500 rpm) and welding speed (10 mm/min, 30 mm/min, 50 mm/min) as welding parameters. The effect of FSW using this welding parameter was studied by measuring the ultimate tensile strength of the welded joints. A high-speed steel tool was prepared for welding the Aluminium AA1100 alloy having an 8mm shoulder diameter and pin dimension of 4mm diameter and 2.8 mm length. The welded joints were tested using the universal testing machine. It was found that Ultimate Tensile Strength of FSW specimen was highest with a value of 98.08 MPa when the weld was performed at rotation speed of 1500 RPM and welding speed of 50 mm/min.

  4. ARTHROSCOPIC TREATMENT OF FEMOROACETABULAR IMPINGEMENT

    PubMed Central

    Polesello, Giancarlo C.; Queiroz, Marcelo C.; Ono, Nelson K.; Honda, Emerson K.; Guimarāes, Rodrigo P; Junior, Walter Ricioli

    2015-01-01

    Objective: The purpose of this study is to evaluate the short-term follow-up results of arthroscopic treatment of femoroacetabular impingement. Our hypothesis is that arthroscopic treatment results are favorable. Methods: Between August 2003 and August 2007, 28 hips had femoroacetabular impingement treated by hip arthroscopy. The mean age was 34 years, with mean follow-up period of 27 months. Clinical results were graded with the modified Harris hip score, which was measured pre- and postoperatively. Patients had also their internal rotation analyzed. These parameters were calculated by using Wilcoxon's t test for analysis of nonparametric paired samples performed. Results: The mean preoperative Harris Hip Score was 54.2, improving to 94.8 postoperatively (p<0,001). The mean increase was 37.5 points. We had 4 good results (15%) and 24 excellent results (85%). Preoperatively, the patients had a mean internal rotation of 17°, and, postoperatively, 36°. The average internal rotation increase was 19° (p<0,001). Conclusions: The arthroscopic treatment of femoroacetabular impingement presents satisfactory results. PMID:27004177

  5. Tests for Z-direction fiber orientation

    Treesearch

    David W. Vahey; John M. Considine

    2007-01-01

    Fibers that acquire a Z-direction tilt in the forming process help bond adjacent strata of the paper sheet, increasing Z-direction shear and other properties. For certain tests, this manifests itself as a test difference upon 180° in-plane rotation of the sheet. Seven of eight different paper grades ranging in grammage from 73 to 268 g/m2 were found to show this...

  6. Beyond the Professional Development Academy: Teachers' Retention of Discipline-Specific Science Content Knowledge throughout a 3-Year Mathematics and Science Partnership

    ERIC Educational Resources Information Center

    Clary, Renee M.; Elder, Anastasia; Dunne, James; Saebo, Svein; Beard, Debbie; Wax, Charles; Tucker, Deborah L.

    2018-01-01

    The Teacher Academy in the Natural Sciences (TANS) provided middle school (U.S. Grades 6-8) teachers (N = 81) with intensive professional development (PD) in chemistry, geosciences, and physics, with teachers enrolled in one scientific discipline per year. Because some teachers were retained and rotated into different disciplines, the TANS program…

  7. FOREX - an expert system for managing even-aged upland oak forests on steep terrain

    Treesearch

    Chris B. LeDoux; B. Gopalakrishnan; K. Lankalapalli

    1995-01-01

    An expert system, FOREX, was developed to access the data from the database management provided by MANAGE. For a specific site index, the user of FOREX can obtain information on present net worth, optimal thinning entry timing, optimal stand rotation age, diameter at breast height, volume by grade and value of the trees harvested, and based on the cable yarder used,...

  8. Ottawa Panel evidence-based clinical practice guidelines for therapeutic exercise in the management of hip osteoarthritis.

    PubMed

    Brosseau, Lucie; Wells, George A; Pugh, Arlanna G; Smith, Christine Am; Rahman, Prinon; Àlvarez Gallardo, Inmaculada C; Toupin-April, Karine; Loew, Laurianne; De Angelis, Gino; Cavallo, Sabrina; Taki, Jade; Marcotte, Rachel; Fransen, Marlene; Hernandez-Molina, Gabriela; Kenny, Glen P; Regnaux, Jean-Philippe; Lefevre-Colau, Marie-Martine; Brooks, Sydney; Laferriere, Lucie; McLean, Linda; Longchamp, Guy

    2016-10-01

    The primary objective is to identify effective land-based therapeutic exercise interventions and provide evidence-based recommendations for managing hip osteoarthritis. A secondary objective is to develop an Ottawa Panel evidence-based clinical practice guideline for hip osteoarthritis. The search strategy and modified selection criteria from a Cochrane review were used. Studies included hip osteoarthritis patients in comparative controlled trials with therapeutic exercise interventions. An Expert Panel arrived at a Delphi survey consensus to endorse the recommendations. The Ottawa Panel hierarchical alphabetical grading system (A, B, C+, C, D, D+, or D-) considered the study design (level I: randomized controlled trial and level II: controlled clinical trial), statistical significance (p < 0.5), and clinical importance (⩾15% improvement). Four high-quality studies were included, which demonstrated that variations of strength training, stretching, and flexibility exercises are generally effective for improving the management of hip osteoarthritis. Strength training exercises displayed the greatest improvements for pain (Grade A), disability (Grades A and C+), physical function (Grade A), stiffness (Grade A), and range of motion (Grade A) within a short time period (8-24 weeks). Stretching also greatly improved physical function (Grade A), and flexibility exercises improved pain (Grade A), range of motion (Grade A), physical function (Grade A), and stiffness (Grade C+). The Ottawa Panel recommends land-based therapeutic exercise, notably strength training, for management of hip osteoarthritis in reducing pain, stiffness and self-reported disability, and improving physical function and range of motion. © The Author(s) 2015.

  9. Specific features of after-school program quality: associations with children's functioning in middle childhood.

    PubMed

    Pierce, Kim M; Bolt, Daniel M; Vandell, Deborah Lowe

    2010-06-01

    This longitudinal study examined associations between three after-school program quality features (positive staff-child relations, available activities, programming flexibility) and child developmental outcomes (reading and math grades, work habits, and social skills with peers) in Grade 2 and then Grade 3. Participants (n = 120 in Grade 2, n = 91 in Grade 3) attended after-school programs more than 4 days per week, on average. Controlling for child and family background factors and children's prior functioning on the developmental outcomes, positive staff-child relations in the programs were positively associated with children's reading grades in both Grades 2 and 3, and math grades in Grade 2. Positive staff-child relations also were positively associated with social skills in Grade 2, for boys only. The availability of a diverse array of age-appropriate activities at the programs was positively associated with children's math grades and classroom work habits in Grade 3. Programming flexibility (child choice of activities) was not associated with child outcomes.

  10. Topology optimized design of functionally graded piezoelectric ultrasonic transducers

    NASA Astrophysics Data System (ADS)

    Rubio, Wilfredo Montealegre; Buiochi, Flávio; Adamowski, Julio Cezar; Silva, Emílio C. N.

    2010-01-01

    This work presents a new approach to systematically design piezoelectric ultrasonic transducers based on Topology Optimization Method (TOM) and Functionally Graded Material (FGM) concepts. The main goal is to find the optimal material distribution of Functionally Graded Piezoelectric Ultrasonic Transducers, to achieve the following requirements: (i) the transducer must be designed to have a multi-modal or uni-modal frequency response, which defines the kind of generated acoustic wave, either short pulse or continuous wave, respectively; (ii) the transducer is required to oscillate in a thickness extensional mode or piston-like mode, aiming at acoustic wave generation applications. Two kinds of piezoelectric materials are mixed for producing the FGM transducer. Material type 1 represents a PZT-5A piezoelectric ceramic and material type 2 represents a PZT-5H piezoelectric ceramic. To illustrate the proposed method, two Functionally Graded Piezoelectric Ultrasonic Transducers are designed. The TOM has shown to be a useful tool for designing Functionally Graded Piezoelectric Ultrasonic Transducers with uni-modal or multi-modal dynamic behavior.

  11. Socioeconomic inequalities in physical and mental functioning of British, Finnish, and Japanese civil servants: role of job demand, control, and work hours.

    PubMed

    Sekine, Michikazu; Chandola, Tarani; Martikainen, Pekka; Marmot, Michael; Kagamimori, Sadanobu

    2009-11-01

    This study aims to evaluate whether the pattern of socioeconomic inequalities in physical and mental functioning as measured by the Short Form 36 (SF-36) differs among employees in Britain, Finland, and Japan and whether work characteristics contribute to some of the health inequalities. The participants were 7340 (5122 men and 2218 women) British employees, 2297 (1638 men and 659 women) Japanese employees, and 8164 (1649 men and 6515 women) Finnish employees. All the participants were civil servants aged 40-60 years. Both male and female low grade employees had poor physical functioning in all cohorts. British and Japanese male low grade employees tended to have poor mental functioning but the associations were significant only for Japanese men. No consistent employment-grade differences in mental functioning were observed among British and Japanese women. Among Finnish men and women, high grade employees had poor mental functioning. In all cohorts, high grade employees had high control, high demands and long work hours. The grade differences in poor physical functioning and disadvantaged work characteristics among non-manual workers were somewhat smaller in the Finnish cohort than in the British and Japanese cohorts. Low control, high demands, and both short and long work hours were associated with poor functioning. When work characteristics were adjusted for, the socioeconomic differences in poor functioning were mildly attenuated in men, but the differences increased slightly in women. This study reconfirms the generally observed pattern of socioeconomic inequalities in health for physical functioning but not for mental functioning. The role of work characteristics in the relationship between socioeconomic status and health differed between men and women but was modest overall. We suggest that these differences in the pattern and magnitude of grade differences in work characteristics and health among the 3 cohorts may be attributable to the different welfare regimes among the 3 countries.

  12. Socioeconomic Inequalities in Physical and Mental Functioning of British, Finnish, and Japanese Civil Servants: Role of Job Demand, Control, and Work Hours

    PubMed Central

    Chandola, Tarani; Martikainen, Pekka; Marmot, Michael; Kagamimori, Sadanobu

    2009-01-01

    This study aims to evaluate whether the pattern of socioeconomic inequalities in physical and mental functioning as measured by the Short Form 36 (SF-36) differs among employees in Britain, Finland, and Japan and whether work characteristics contribute to some of the health inequalities. The participants were 7340 (5122 men and 2218 women) British employees, 2297 (1638 men and 659 women) Japanese employees, and 8164 (1649 men and 6515 women) Finnish employees. All the participants were civil servants aged 40–60 years. Both male and female low grade employees had poor physical functioning in all cohorts. British and Japanese male low grade employees tended to have poor mental functioning but the associations were significant only for Japanese men. No consistent employment-grade differences in mental functioning were observed among British and Japanese women. Among Finnish men and women, high grade employees had poor mental functioning. In all cohorts, high grade employees had high control, high demands and long work hours. The grade differences in poor physical functioning and disadvantaged work characteristics among non-manual workers were somewhat smaller in the Finnish cohort than in the British and Japanese cohorts. Low control, high demands, and both short and long work hours were associated with poor functioning. When work characteristics were adjusted for, the socioeconomic differences in poor functioning were mildly attenuated in men, but the differences increased slightly in women. This study reconfirms the generally observed pattern of socioeconomic inequalities in health for physical functioning but not for mental functioning. The role of work characteristics in the relationship between socioeconomic status and health differed between men and women but was modest overall. We suggest that these differences in the pattern and magnitude of grade differences in work characteristics and health among the 3 cohorts may be attributable to the different welfare regimes among the 3 countries. PMID:19767137

  13. Computational Study of a Functionally Graded Ceramic-Metallic Armor

    DTIC Science & Technology

    2006-12-15

    UNCLAS –Dist. A - Approved for public release Computational Study of a Functionally Graded Ceramic-Metallic Armor Douglas W. Templeton1, Tara J...efficiency of a postulated FGM ceramic-metallic armor system composed of aluminum nitride (AlN) and aluminum. The study had two primary...2006 2. REPORT TYPE N/ A 3. DATES COVERED - 4. TITLE AND SUBTITLE Computational Study of a Functionally Graded Ceramic-Metallic Armor 5a

  14. Psychological Symptoms Linking Exposure to Community Violence and Academic Functioning in African American Adolescents

    PubMed Central

    Busby, Danielle R.; Lambert, Sharon F.; Ialongo, Nicholas S.

    2013-01-01

    African American adolescents are exposed disproportionately to community violence, increasing their risk for emotional and behavioral symptoms that can detract from learning and undermine academic outcomes. The present study examined whether aggressive behavior and depressive and anxious symptoms mediated the association between exposure to community violence and academic functioning, and if the indirect effects of community violence on academic functioning differed for boys and girls, in a community sample of urban African American adolescents (N = 491; 46.6% female). Structural equation modeling was used to examine the indirect effect of exposure to community violence in grade 6 on grade 8 academic functioning. Results revealed that aggression in grade 7 mediated the association between grade 6 exposure to community violence and grade 8 academic functioning. There were no indirect effects through depressive and anxious symptoms, and gender did not moderate the indirect effect. Findings highlight the importance of targeting aggressive behavior for youth exposed to community violence to not only improve their behavioral adjustment but also their academic functioning. Implications for future research are discussed. PMID:23277294

  15. Social Competence and Social Support as Mediators between Comorbid Depressive and Conduct Problems and Functional Outcomes in Middle School Students

    PubMed Central

    Rockhill, Carol M.; Stoep, Ann Vander; McCauley, Elizabeth; Katon, Wayne J.

    2009-01-01

    This study examined the roles of social competence and social support as potential mediators of the association between psychopathology and functional outcomes in a middle school sample (n=521). Participants were stratified into four psychopathology risk groups (depression only, conduct problems only, comorbid depression and conduct problems, low symptoms) based on screening during early 6th grade. Functional outcomes were 6th grade point average (GPA) and parent rating of global adaptive functioning in their 7th grade student. Low levels of social competence were found to mediate the association between psychiatric symptoms and both lower grades and global functioning, for adolescents with depressive symptoms alone and with comorbid symptoms, but not for those with conduct problems alone. Lack of social support mediated the association between symptoms and lower grades for adolescents with depression alone and comorbid symptoms, but not those with conduct problems alone. These findings suggest that intervention to improve social competence and social support may enhance functional outcomes, especially for youth with depressive symptoms or comorbid depressive and conduct symptoms. PMID:18694594

  16. Bioinspired design of dental multilayers.

    PubMed

    Huang, M; Wang, R; Thompson, V; Rekow, D; Soboyejo, W O

    2007-01-01

    This paper considers the use of bioinspired functionally graded structures in the design of dental multi-layers that are more resistant to sub-surface crack nucleation. Unlike existing dental crown restorations that give rise to high stress concentration, the functionally graded layers (between crown materials and the joins that attach them to dentin) are shown to promote significant reductions in stress and improvements in the critical crack size. Special inspiration is drawn from the low stress concentrations associated with the graded distributions in the dentin-enamel-junction (DEJ). The implications of such functionally graded structures are also discussed for the design of dental restorations.

  17. Reverse shoulder arthroplasty combined with latissimus dorsi transfer using the bone-chip technique.

    PubMed

    Ortmaier, Reinhold; Resch, Herbert; Hitzl, Wolfgang; Mayer, Michael; Blocher, Martina; Vasvary, Imre; Mattiassich, Georg; Stundner, Ottokar; Tauber, Mark

    2014-03-01

    Reverse shoulder arthroplasty (RSA) can restore active elevation in rotator-cuff-deficient shoulders. However, RSA cannot restore active external rotation. The combination of latissimus dorsi transfer with RSA has been reported to restore both active elevation and external rotation. We hypothesised that in the combined procedure, harvesting the latissimus dorsi with a small piece of bone, leads to good tendon integrity, low rupture rates and good clinical outcome. Between 2004 and 2010, 13 patients (13 shoulders) were treated with RSA in combination with latissimus dorsi transfer in a modified manner. The mean follow-up was 65.4 months, and the mean age at index surgery was 71.1 years. All patients had external rotation lag sign and positive hornblower's sign, as well as radiological signs of cuff-tear arthropathy (Hamada 3, 4 or 5) and fatty infiltration grade 3 according to Goutallier et al. on magnetic resonance imaging (MRI). The outcome measures included the Constant Murley Score, University of California-Los Angeles (UCLA) shoulder score, Simple Shoulder Test (SST), visual analogue scale (VAS) and the Activities of Daily Living Requiring External Rotation (ADLER) score. Tendon integrity was evaluated with dynamic ultrasound. All patients were asked at final follow-up to rate their satisfaction as excellent, good, satisfied or dissatisfied. The overall mean Constant-Murley Shoulder Outcome Score (CMS) improved from 20.4 to 64.3 points (p < 0.001). Mean VAS pain score decreased from 6.8 to 1.1 (p < 0.001)., mean UCLA score improved from 7.9 to 26.4 (p < 0.001), mean SST score improved from 2.3 to 7.9 (p < 0.001) and mean postoperative ADLER score was 26 points. The average degree of abduction improved from 45° to 129° (p < 0.001), the average degree of anterior flexion improved from 55° to 138° (p < 0.001) and the average degree of external rotation improved from -16° to 21° (p < 0.001). Eight patients rated their results as very satisfied, three as satisfied and two as dissatisfied. This modified technique, which avoids cutting the pectoralis major tendon and involves harvesting the tendon together with a small piece of bone, leads to good or even better functional results compared with the results reported in the literature, and also has high patient satisfaction and low failure rates.

  18. NMR spin-rotation relaxation and diffusion of methane

    NASA Astrophysics Data System (ADS)

    Singer, P. M.; Asthagiri, D.; Chapman, W. G.; Hirasaki, G. J.

    2018-05-01

    The translational diffusion-coefficient and the spin-rotation contribution to the 1H NMR relaxation rate for methane (CH4) are investigated using MD (molecular dynamics) simulations, over a wide range of densities and temperatures, spanning the liquid, supercritical, and gas phases. The simulated diffusion-coefficients agree well with measurements, without any adjustable parameters in the interpretation of the simulations. A minimization technique is developed to compute the angular velocity for non-rigid spherical molecules, which is used to simulate the autocorrelation function for spin-rotation interactions. With increasing diffusivity, the autocorrelation function shows increasing deviations from the single-exponential decay predicted by the Langevin theory for rigid spheres, and the deviations are quantified using inverse Laplace transforms. The 1H spin-rotation relaxation rate derived from the autocorrelation function using the "kinetic model" agrees well with measurements in the supercritical/gas phase, while the relaxation rate derived using the "diffusion model" agrees well with measurements in the liquid phase. 1H spin-rotation relaxation is shown to dominate over the MD-simulated 1H-1H dipole-dipole relaxation at high diffusivity, while the opposite is found at low diffusivity. At high diffusivity, the simulated spin-rotation correlation time agrees with the kinetic collision time for gases, which is used to derive a new expression for 1H spin-rotation relaxation, without any adjustable parameters.

  19. Thalamic diffusion differences related to cognitive function in white matter lesions.

    PubMed

    Fernández-Andújar, Marina; Soriano-Raya, Juan José; Miralbell, Júlia; López-Cancio, Elena; Cáceres, Cynthia; Bargalló, Núria; Barrios, Maite; Arenillas, Juan Francisco; Toran, Pere; Alzamora, Maite; Clemente, Imma; Dávalos, Antoni; Mataró, Maria

    2014-05-01

    Cerebral white matter lesions (WMLs) are related to cognitive deficits, probably due to a disruption of frontal-subcortical circuits. We explored thalamic diffusion differences related to white matter lesions (WMLs) and their association with cognitive function in middle-aged individuals. Ninety-six participants from the Barcelona-AsIA Neuropsychology Study were included. Participants were classified into groups based on low grade and high grade of periventricular hyperintensities (PVHs) and deep white matter hyperintensities (DWMHs). Tract-Based Spatial Statistics was used to study thalamic diffusion differences between groups. Mean fractional anisotropy (FA) values in significant areas were calculated for each subject and correlated with cognitive performance. Participants with high-grade PVHs and DWMHs showed lower FA thalamic values compared to those with low-grade PVHs and DWMHs, respectively. Decreased FA thalamic values in high-grade DWMHs, but not high-grade PVH, were related to lower levels of performance in psychomotor speed, verbal fluency, and visuospatial skills. Thalamic diffusion differences are related to lower cognitive function only in participants with high-grade DWMHs. These results support the hypothesis that fronto-subcortical disruption is associated with cognitive function only in DWMHs. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. High-grade ovarian cancer secreting effective exosomes in tumor angiogenesis.

    PubMed

    Yi, Huan; Ye, Jun; Yang, Xiao-Mei; Zhang, Li-Wen; Zhang, Zhi-Gang; Chen, Ya-Ping

    2015-01-01

    Ovarian cancer, the most lethal gynecological cancer, related closely to tumor stage. High-grade ovarian cancer always results in a late diagnose and high recurrence, which reduce survival within five years. Until recently, curable therapy is still under research and anti-angiogenesis proves a promising way. Tumor-derived exosomes are essential in tumor migration and metastases such as angiogenesis is enhanced by exosomes. In our study, we have made comparison between high-grade and unlikely high-grade serous ovarian cancer cells on exosomal function of endothelial cells proliferation, migration and tube formation. Exosomes derived from high-grade ovarian cancer have a profound impact on angiogenesis with comparison to unlikely high-grade ovarian cancer. Proteomic profiles revealed some potential proteins involved in exosomal function of angiogenesis such as ATF2, MTA1, ROCK1/2 and so on. Therefore, exosomes plays an influential role in angiogenesis in ovarian serous cancer and also function more effectively in high-grade ovarian cancer cells.

  1. In touch with mental rotation: interactions between mental and tactile rotations and motor responses.

    PubMed

    Lohmann, Johannes; Rolke, Bettina; Butz, Martin V

    2017-04-01

    Although several process models have described the cognitive processing stages that are involved in mentally rotating objects, the exact nature of the rotation process itself remains elusive. According to embodied cognition, cognitive functions are deeply grounded in the sensorimotor system. We thus hypothesized that modal rotation perceptions should influence mental rotations. We conducted two studies in which participants had to judge if a rotated letter was visually presented canonically or mirrored. Concurrently, participants had to judge if a tactile rotation on their palm changed direction during the trial. The results show that tactile rotations can systematically influence mental rotation performance in that same rotations are favored. In addition, the results show that mental rotations produce a response compatibility effect: clockwise mental rotations facilitate responses to the right, while counterclockwise mental rotations facilitate responses to the left. We conclude that the execution of mental rotations activates cognitive mechanisms that are also used to perceive rotations in different modalities and that are associated with directional motor control processes.

  2. Reversibility of Supraspinatus Muscle Atrophy in Tendon-Bone Healing After Arthroscopic Rotator Cuff Repair.

    PubMed

    Park, Yong Bok; Ryu, Ho Young; Hong, Jin Ho; Ko, Young Hoo; Yoo, Jae Chul

    2016-04-01

    To date, there are few reports of the definite reversibility of rotator cuff muscle atrophy after repair. To evaluate the reversibility of rotator cuff muscle atrophy after successful arthroscopic repair. Case series; Level of evidence, 4. Included in this study were 47 patients (mean age, 61.2 ± 7.3 years; range, 49-73 years) who underwent arthroscopic rotator cuff repair as well as magnetic resonance imaging (MRI) preoperatively and at 6-month and last follow-up. Patients who had confirmed rotator cuff healing (grades 1-3 according to the Sugaya classification) on both series of postoperative MRI were enrolled in the study. The mean time from the onset of symptoms to surgery was 24.7 ± 25.6 months (range, 3-120 months). The minimum follow-up was 2 years, and the mean follow-up duration was 41.8 ± 14.4 months. Serial changes in the supraspinatus muscle area on the most matching MRI scans (sagittal-oblique view) were evaluated. The area was measured by 2 independent observers. Both independent observers reported no significant difference in the area of the supraspinatus muscle between the preoperative time point and 6-month follow-up (observer 1: P = .135; observer 2: P = .189). However, there was a significant difference between the 6-month and last follow-up (mean, 41.8 months; observers 1 and 2: P < .001). The serial changes in the area preoperatively and at 6-month and last follow-up were 419.41 ± 122.97 mm(2), 431.76 ± 104.27 mm(2), and 466.73 ± 121.42 mm(2), respectively (observer 1), and 421.01 ± 116.61 mm(2), 432.56 ± 100.78 mm(2), and 469.84 ± 113.80 mm(2), respectively (observer 2). The intraclass correlation coefficient between the 2 observers was 0.988. At final follow-up, the area increase on the medial and lateral aspects of the sagittal-oblique view compared with preoperatively was 13.9% (P < .001) and 11.3% (P < .001), respectively. Fatty infiltration did not change from preoperatively to 6-month follow-up (P > .999) or from 6-month to final follow-up (P = .077). After successful arthroscopic rotator cuff repair, there was a slight (11.3%-13.9%) increase in muscle volume from preoperatively to final follow-up, as seen on serial MRI. Fatty infiltration according to the Goutallier grade was not reversed (P = .077). Some reversibility of supraspinatus muscle atrophy may exist in tendon-bone healing after arthroscopic rotator cuff repair; further follow-up is needed to better elucidate this result. © 2016 The Author(s).

  3. Comparison of the Diagnostic Accuracy of DSC- and Dynamic Contrast-Enhanced MRI in the Preoperative Grading of Astrocytomas.

    PubMed

    Nguyen, T B; Cron, G O; Perdrizet, K; Bezzina, K; Torres, C H; Chakraborty, S; Woulfe, J; Jansen, G H; Sinclair, J; Thornhill, R E; Foottit, C; Zanette, B; Cameron, I G

    2015-11-01

    Dynamic contrast-enhanced MR imaging parameters can be biased by poor measurement of the vascular input function. We have compared the diagnostic accuracy of dynamic contrast-enhanced MR imaging by using a phase-derived vascular input function and "bookend" T1 measurements with DSC MR imaging for preoperative grading of astrocytomas. This prospective study included 48 patients with a new pathologic diagnosis of an astrocytoma. Preoperative MR imaging was performed at 3T, which included 2 injections of 5-mL gadobutrol for dynamic contrast-enhanced and DSC MR imaging. During dynamic contrast-enhanced MR imaging, both magnitude and phase images were acquired to estimate plasma volume obtained from phase-derived vascular input function (Vp_Φ) and volume transfer constant obtained from phase-derived vascular input function (K(trans)_Φ) as well as plasma volume obtained from magnitude-derived vascular input function (Vp_SI) and volume transfer constant obtained from magnitude-derived vascular input function (K(trans)_SI). From DSC MR imaging, corrected relative CBV was computed. Four ROIs were placed over the solid part of the tumor, and the highest value among the ROIs was recorded. A Mann-Whitney U test was used to test for difference between grades. Diagnostic accuracy was assessed by using receiver operating characteristic analysis. Vp_ Φ and K(trans)_Φ values were lower for grade II compared with grade III astrocytomas (P < .05). Vp_SI and K(trans)_SI were not significantly different between grade II and grade III astrocytomas (P = .08-0.15). Relative CBV and dynamic contrast-enhanced MR imaging parameters except for K(trans)_SI were lower for grade III compared with grade IV (P ≤ .05). In differentiating low- and high-grade astrocytomas, we found no statistically significant difference in diagnostic accuracy between relative CBV and dynamic contrast-enhanced MR imaging parameters. In the preoperative grading of astrocytomas, the diagnostic accuracy of dynamic contrast-enhanced MR imaging parameters is similar to that of relative CBV. © 2015 by American Journal of Neuroradiology.

  4. Musculoskeletal disorder risk as a function of vehicle rotation angle during assembly tasks.

    PubMed

    Ferguson, Sue A; Marras, Williams S; Gary Allread, W; Knapik, Gregory G; Vandlen, Kimberly A; Splittstoesser, Riley E; Yang, Gang

    2011-07-01

    Musculoskeletal disorders (MSD) are costly and common problem in automotive manufacturing. The research goal was to quantify MSD exposure as a function of vehicle rotation angle and region during assembly tasks. The study was conducted at the Center for Occupational Health in Automotive Manufacturing (COHAM) Laboratory. Twelve subjects participated in the study. The vehicle was divided into seven regions, (3 interior, 2 underbody and 2 engine regions) representative of work areas during assembly. Three vehicle rotation angles were examined for each region. The standard horizontal assembly condition (0° rotation) was the reference frame. Exposure was assessed on the spine loads and posture, shoulder posture and muscle activity, neck posture and muscle activity as well as wrist posture. In all regions, rotating the vehicle reduced musculoskeletal exposure. In five of the seven regions 45° of vehicle rotation represented the position that reduced MSD exposure most. Two of the seven regions indicated 90° of vehicle rotation had the greatest impact for reducing MSD exposure. This study demonstrated that vehicle rotation shows promise for reducing exposure to risk factors for MDS during automobile assembly tasks. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  5. Comparison of fasciocutaneous V-Y and rotational flaps for defect coverage of sacral pressure sores: a critical single-centre appraisal.

    PubMed

    Djedovic, Gabriel; Metzler, Julia; Morandi, Evi M; Wachter, Tanja; Kühn, Shafreena; Pierer, Gerhard; Rieger, Ulrich M

    2017-12-01

    Pressure sore rates remain high in both nursing homes as well as in hospitals. Numerous surgical options are available for defect coverage in the sacral region. However, objective data is scarce as to whether a specific flap design is superior to another. Here, we aim to compare two fasciocutaneous flap designs for sacral defect coverage: the gluteal rotation flap and the gluteal V-Y flap. All primary sacral pressure sores of grades III-IV that were being covered with gluteal fasciocutaneous rotational or V-Y flaps between January 2008 and December 2014 at our institution were analysed. A total of 41 patients received a total of 52 flaps. Of these, 18 patients received 20 gluteal rotational flaps, and 23 patients received 32 V-Y flaps. Both groups were comparable with regards to demographics, comorbidities and complications. Significantly more V-Y flaps were needed to cover smaller defects. Mean length of hospital stay was significantly prolonged when surgical revision had to be carried out. Both flap designs have proven safe and reliable for defect coverage after sacral pressure sores. Gluteal rotational flaps appear to be more useful for larger defects. Both flap designs facilitate their reuse in case of pressure sore recurrence. Complication rates appear to be comparable in both designs and to the current literature. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  6. Mechanical analysis of non-uniform bi-directional functionally graded intelligent micro-beams using modified couple stress theory

    NASA Astrophysics Data System (ADS)

    Bakhshi Khaniki, Hossein; Rajasekaran, Sundaramoorthy

    2018-05-01

    This study develops a comprehensive investigation on mechanical behavior of non-uniform bi-directional functionally graded beam sensors in the framework of modified couple stress theory. Material variation is modelled through both length and thickness directions using power-law, sigmoid and exponential functions. Moreover, beam is assumed with linear, exponential and parabolic cross-section variation through the length using power-law and sigmoid varying functions. Using these assumptions, a general model for microbeams is presented and formulated by employing Hamilton’s principle. Governing equations are solved using a mixed finite element method with Lagrangian interpolation technique, Gaussian quadrature method and Wilson’s Lagrangian multiplier method. It is shown that by using bi-directional functionally graded materials in nonuniform microbeams, mechanical behavior of such structures could be affected noticeably and scale parameter has a significant effect in changing the rigidity of nonuniform bi-directional functionally graded beams.

  7. Generalization of Jacobi's Decomposition Theorem to the Rotation and Translation of a Solid in a Fluid.

    NASA Astrophysics Data System (ADS)

    Chiang, Rong-Chang

    Jacobi found that the rotation of a symmetrical heavy top about a fixed point is composed of the two torque -free rotations of two triaxial bodies about their centers of mass. His discovery rests on the fact that the orthogonal matrix which represents the rotation of a symmetrical heavy top is decomposed into a product of two orthogonal matrices, each of which represents the torque-free rotations of two triaxial bodies. This theorem is generalized to the Kirchhoff's case of the rotation and translation of a symmetrical solid in a fluid. This theorem requires the explicit computation, by means of theta functions, of the nine direction cosines between the rotating body axes and the fixed space axes. The addition theorem of theta functions makes it possible to decompose the rotational matrix into a product of similar matrices. This basic idea of utilizing the addition theorem is simple but the carry-through of the computation is quite involved and the full proof turns out to be a lengthy process of computing rather long and complex expressions. For the translational motion we give a new treatment. The position of the center of mass as a function of the time is found by a direct evaluation of the elliptic integral by means of a new theta interpretation of Legendre's reduction formula of the elliptic integral. For the complete solution of the problem we have added further the study of the physical aspects of the motion. Based on a complete examination of the all possible manifolds of the steady helical cases it is possible to obtain a full qualitative description of the motion. Many numerical examples and graphs are given to illustrate the rotation and translation of the solid in a fluid.

  8. Rotor noise due to blade-turbulence interaction

    NASA Astrophysics Data System (ADS)

    Ishimaru, K.

    1983-01-01

    The time-averaged intensity density function of the acoustic radiation from rotating blades is derived by replacing blades with rotating dipoles. This derivation is done under the following turbulent inflow conditions: turbulent ingestion with no inlet strut wakes, inflow turbulence elongation and contraction with no inlet strut wakes, and inlet strut wakes. Dimensional analysis reveals two non-dimensional parameters which play important roles in generating the blade-passing frequency tone and its multiples. The elongation and contraction of inflow turbulence has a strong effect on the generation of the blade-passing frequency tone and its multiples. Increasing the number of rotor blades widens the peak at the blade-passing frequency and its multiples. Increasing the rotational speed widens the peak under the condition that the non-dimensional parameter involving the rotational speed is fixed. The number of struts and blades should be chosen so that (the least common multiple of them)-(rotational speed) is in the cutoff range of Sears' function, in order to minimize the effect of the mean flow deficit on the time averaged intensity density function.

  9. 3D finite element models of shoulder muscles for computing lines of actions and moment arms.

    PubMed

    Webb, Joshua D; Blemker, Silvia S; Delp, Scott L

    2014-01-01

    Accurate representation of musculoskeletal geometry is needed to characterise the function of shoulder muscles. Previous models of shoulder muscles have represented muscle geometry as a collection of line segments, making it difficult to account for the large attachment areas, muscle-muscle interactions and complex muscle fibre trajectories typical of shoulder muscles. To better represent shoulder muscle geometry, we developed 3D finite element models of the deltoid and rotator cuff muscles and used the models to examine muscle function. Muscle fibre paths within the muscles were approximated, and moment arms were calculated for two motions: thoracohumeral abduction and internal/external rotation. We found that muscle fibre moment arms varied substantially across each muscle. For example, supraspinatus is considered a weak external rotator, but the 3D model of supraspinatus showed that the anterior fibres provide substantial internal rotation while the posterior fibres act as external rotators. Including the effects of large attachment regions and 3D mechanical interactions of muscle fibres constrains muscle motion, generates more realistic muscle paths and allows deeper analysis of shoulder muscle function.

  10. 3D Finite Element Models of Shoulder Muscles for Computing Lines of Actions and Moment Arms

    PubMed Central

    Webb, Joshua D.; Blemker, Silvia S.; Delp, Scott L.

    2014-01-01

    Accurate representation of musculoskeletal geometry is needed to characterize the function of shoulder muscles. Previous models of shoulder muscles have represented muscle geometry as a collection of line segments, making it difficult to account the large attachment areas, muscle-muscle interactions, and complex muscle fiber trajectories typical of shoulder muscles. To better represent shoulder muscle geometry we developed three-dimensional finite element models of the deltoid and rotator cuff muscles and used the models to examine muscle function. Muscle fiber paths within the muscles were approximated, and moment arms were calculated for two motions: thoracohumeral abduction and internal/external rotation. We found that muscle fiber moment arms varied substantially across each muscle. For example, supraspinatus is considered a weak external rotator, but the three-dimensional model of supraspinatus showed that the anterior fibers provide substantial internal rotation while the posterior fibers act as external rotators. Including the effects of large attachment regions and three-dimensional mechanical interactions of muscle fibers constrains muscle motion, generates more realistic muscle paths, and allows deeper analysis of shoulder muscle function. PMID:22994141

  11. The Relationship Between Body Mass Index and Fatty Infiltration in the Shoulder Musculature.

    PubMed

    Dow, David F; Mehta, Kaushal; Xu, Yuanfang; England, Eric

    Fatty infiltration in the rotator cuff muscles has been well studied in the setting of rotator cuff tendon tears to help predict outcomes of surgical repair. Fatty infiltration in the rotator cuff has also been independently correlated to the variables of age and sex. The purpose of our study was to determine if there is a relationship between body mass index and fatty infiltration in patients with no imaging evidence of rotator cuff tendinosis or tear. Radiology reports of all magnetic resonance imaging examinations of the shoulder were searched over a 2-year period. Studies with imaging findings of rotator cuff tendinosis, partial tear, or full thickness tear were excluded from the study, resulting in a total of 143 patients with normal rotator cuffs who were included in the study. These studies were reviewed by consensus by 2 fellowship-trained musculoskeletal radiologists who used the Goutallier 5-stage scoring system to grade the supraspinatus, infraspinatus, subscapularis, teres minor, teres major, and deltoid muscles. Sex was shown not to be significantly associated with fatty infiltration with the exception of the deltoid muscle, which showed a statistically significant increase in fatty infiltration associated with female sex (P = 0.038). Age was shown to be a statistically significant predictor of fatty infiltration for all 6 muscles (P < 0.05). Body mass index was shown to be a statistically significant predictor of fatty infiltration for all of the evaluated shoulder musculature (P < 0.05) with the exception of the teres minor. Our results suggest that increased body mass index is associated with increased fatty infiltration in the supraspinatus, infraspinatus, subscapularis, teres major, and deltoid muscles. This relationship could help guide the decisions of orthopedic surgeons when considering rotator cuff repair.

  12. Reverse arthroplasty for osteoarthritis and rotator cuff deficiency after previous surgery for recurrent anterior shoulder instability.

    PubMed

    Raiss, Patric; Zeifang, Felix; Pons-Villanueva, Juan; Smithers, Christopher J; Loew, Markus; Walch, Gilles

    2014-07-01

    Osteoarthritis in combination with rotator cuff deficiency following previous shoulder stabilisation surgery and after failed surgical treatment for chronic anterior shoulder dislocation is a challenging condition. The aim of this study was to analyse the results of reverse shoulder arthroplasty in such patients. Thirteen patients with a median follow-up of 3.5 (range two to eight) years and a median age of 70 (range 48-82) years were included. In all shoulders a tear of at least one rotator cuff tendon in combination with osteoarthritis was present at the time of arthroplasty. The Constant score, shoulder flexion and external and internal rotation with the elbow at the side were documented pre-operatively and at the final follow-up. Pre-operative, immediate post-operative and final follow-up radiographs were analysed. All complications and revisions were documented. Twelve patients were either satisfied or very satisfied with the procedure. The median Constant score increased from 26 points pre-operatively to 67 points at the final follow-up (p = 0.001). The median shoulder flexion increased significantly from 70° to 130° and internal rotation from two to four points (p = 0.002). External rotation did not change significantly (p = 0.55). Glenoid notching was present in five cases and was graded as mild in three cases and moderate in two. One complication occurred leading to revision surgery. Reverse arthroplasty leads to high satisfaction rates for patients with osteoarthritis and rotator cuff deficiency who had undergone previous shoulder stabilisation procedures. The improvements in clinical outcome as well as the radiographic results seem to be comparable with those of other studies reporting on the outcome of reverse shoulder arthroplasty for other conditions.

  13. Clinical Outcomes of Conservative Treatment and Arthroscopic Repair of Rotator Cuff Tears: A Retrospective Observational Study.

    PubMed

    Lee, Woo Hyung; Do, Hyun Kyung; Lee, Joong Hoon; Kim, Bo Ram; Noh, Jee Hyun; Choi, Soo Hyun; Chung, Sun Gun; Lee, Shi-Uk; Choi, Ji Eun; Kim, Seihee; Kim, Min Jee; Lim, Jae-Young

    2016-04-01

    To compare the clinical outcomes following conservative treatment and arthroscopic repair in patients with a rotator cuff tear. In this retrospective study, patients aged >50 years with a symptomatic rotator cuff tear were reviewed. The rotator cuff tendons were evaluated using ultrasonography, shoulder magnetic resonance imaging or MR arthrography, and the patients with either a high-grade partial-thickness or small-to-medium-sized (≤3 cm) full-thickness tear were included in this study. The primary outcome measures were a pain assessment score and range of motion (ROM) at 1-year follow-up. The secondary outcomes were the rate of tear progression or retear along with the rate of symptom aggravation after the treatments. A total of 357 patients were enrolled, including 183 patients that received conservative treatment and 174 patients who received an arthroscopic repair. The pain assessment score (p<0.001) and the ROM in forward flexion (p<0.001) were significantly improved in both groups. The ROM in internal rotation did not significantly change after conservative treatment and arthroscopic repair. The pain assessment score and ROM were not significantly different between the two groups. Retear was observed in 9.6% of patients who had an arthroscopic repair and tear progression was found in 6.7% of those who underwent conservative treatment. The proportion of aggravation for pain and ROM did not significantly differ between the two groups. The effectiveness of conservative treatment is not inferior to arthroscopic repair for patients >50 years old with a less than medium-sized rotator cuff tear in a 1-year follow-up period. Further study is warranted to find the optimal combination of conservative treatment for a symptomatic rotator cuff tear.

  14. Oblique rotaton in canonical correlation analysis reformulated as maximizing the generalized coefficient of determination.

    PubMed

    Satomura, Hironori; Adachi, Kohei

    2013-07-01

    To facilitate the interpretation of canonical correlation analysis (CCA) solutions, procedures have been proposed in which CCA solutions are orthogonally rotated to a simple structure. In this paper, we consider oblique rotation for CCA to provide solutions that are much easier to interpret, though only orthogonal rotation is allowed in the existing formulations of CCA. Our task is thus to reformulate CCA so that its solutions have the freedom of oblique rotation. Such a task can be achieved using Yanai's (Jpn. J. Behaviormetrics 1:46-54, 1974; J. Jpn. Stat. Soc. 11:43-53, 1981) generalized coefficient of determination for the objective function to be maximized in CCA. The resulting solutions are proved to include the existing orthogonal ones as special cases and to be rotated obliquely without affecting the objective function value, where ten Berge's (Psychometrika 48:519-523, 1983) theorems on suborthonormal matrices are used. A real data example demonstrates that the proposed oblique rotation can provide simple, easily interpreted CCA solutions.

  15. Revision versus primary arthroscopic rotator cuff repair: a 2-year analysis of outcomes in 360 patients.

    PubMed

    Shamsudin, Aminudin; Lam, Patrick H; Peters, Karin; Rubenis, Imants; Hackett, Lisa; Murrell, George A C

    2015-03-01

    Symptomatic rotator cuff tears are often treated surgically. However, there is a paucity of information regarding the outcomes of revision arthroscopic rotator cuff repairs. To evaluate the outcome of revision arthroscopic rotator cuff surgery when compared with primary arthroscopic rotator cuff surgery in a large cohort of patients. Cohort study; Level of evidence, 3. A consecutive series of 50 revision arthroscopic rotator cuff repairs performed by a single surgeon, with minimum 2-year follow-up, were retrospectively reviewed using prospectively collected data. As a comparison, 3 primary arthroscopic rotator cuff repair cases (primary group; n = 310) were chosen immediately before each revision case, and 3 were chosen after. Standardized patient-ranked outcomes, examiner-determined assessments, and ultrasound-determined rotator cuff integrity were assessed preoperatively at 6 months and at a minimum of 2 years after surgery. The revision group was older (mean age, 63 years; range, 43-80 years) compared with the primary group (mean age, 60 years; range, 18-88 years) (P < .05) and had larger tear size (mean ± SEM) (4.1 ± 0.5 cm(2)) compared with the primary group (3.0 ± 0.2 cm(2)) (P < .05). Two years after surgery, the primary group reported less pain at rest (P < .02), during sleep (P < .05), and with overhead activity (P < .01) compared with the revision group. The primary group had better passive forward flexion (+13°; P < .05), abduction (+18°; P < .01), internal rotation (+2 vertebral levels; P < .001) and also significantly greater supraspinatus strength (+15 N; P < .001), lift-off strength (+9.3 N; P < .05), and adduction strength (+20 N; P < .01) compared with the revision group at 2 years. When compared with the primary group, the revision group was more satisfied with the overall shoulder function before surgery but was less satisfied with their shoulder function than the primary group at 2 years (P < .005). The retear rate for primary rotator cuff repair was 16% at 6 months and 21% at 2 years, while the retear rate for revision rotator cuff repair was 28% at 6 months and deteriorated to 40% at 2 years (P < .05). The short-term clinical outcomes of patients undergoing revision rotator cuff repair were similar to those after primary rotator cuff repair. However, these results did not persist, and by 2 years patients who had revision rotator cuff repair were twice as likely to have retorn compared with those undergoing primary repair. The increase in retear rate in the revision group at 2 years was associated with increased pain, impaired overhead function, less passive motion, weaker strength, and less overall satisfaction with shoulder function. © 2014 The Author(s).

  16. Efficient calculation of nuclear spin-rotation constants from auxiliary density functional theory.

    PubMed

    Zuniga-Gutierrez, Bernardo; Camacho-Gonzalez, Monica; Bendana-Castillo, Alfonso; Simon-Bastida, Patricia; Calaminici, Patrizia; Köster, Andreas M

    2015-09-14

    The computation of the spin-rotation tensor within the framework of auxiliary density functional theory (ADFT) in combination with the gauge including atomic orbital (GIAO) scheme, to treat the gauge origin problem, is presented. For the spin-rotation tensor, the calculation of the magnetic shielding tensor represents the most demanding computational task. Employing the ADFT-GIAO methodology, the central processing unit time for the magnetic shielding tensor calculation can be dramatically reduced. In this work, the quality of spin-rotation constants obtained with the ADFT-GIAO methodology is compared with available experimental data as well as with other theoretical results at the Hartree-Fock and coupled-cluster level of theory. It is found that the agreement between the ADFT-GIAO results and the experiment is good and very similar to the ones obtained by the coupled-cluster single-doubles-perturbative triples-GIAO methodology. With the improved computational performance achieved, the computation of the spin-rotation tensors of large systems or along Born-Oppenheimer molecular dynamics trajectories becomes feasible in reasonable times. Three models of carbon fullerenes containing hundreds of atoms and thousands of basis functions are used for benchmarking the performance. Furthermore, a theoretical study of temperature effects on the structure and spin-rotation tensor of the H(12)C-(12)CH-DF complex is presented. Here, the temperature dependency of the spin-rotation tensor of the fluorine nucleus can be used to identify experimentally the so far unknown bent isomer of this complex. To the best of our knowledge this is the first time that temperature effects on the spin-rotation tensor are investigated.

  17. Understanding neural system dynamics through task modulation and measurement of functional MRI amplitude, latency, and width

    PubMed Central

    Bellgowan, P. S. F.; Saad, Z. S.; Bandettini, P. A.

    2003-01-01

    Estimates of hemodynamic amplitude, delay, and width were combined to investigate system dynamics involved in lexical decision making. Subjects performed a lexical decision task using word and nonword stimuli rotated 0°, 60°, or 120°. Averaged hemodynamic responses to repeated stimulation were fit to a Gamma-variate function convolved with a heavyside function of varying onset and duration to estimate each voxel's activation delay and width. Consistent with prolonged reaction times for the rotated stimuli and nonwords, the motor cortex showed delayed hemodynamic onset for both conditions. Language areas such as the lingual gyrus, middle temporal gyrus, fusiform gyrus, and precuneus all showed delayed hemodynamic onsets to rotated stimuli but not to nonword stimuli. The inferior frontal gyrus showed both increased onset latency for rotated stimuli and a wider hemodynamic response to nonwords, consistent with prolonged processing in this area during the lexical decision task. Phonological processing areas such as superior temporal and angular gyrus showed no delay or width difference for rotated stimuli. These results suggest that phonological routes but not semantic routes to the lexicon can proceed regardless of stimulus orientation. This study demonstrates the utility of estimating hemodynamic delay and width in addition to amplitude allowing for more quantitative measures of brain function such as mental chronometry. PMID:12552093

  18. On families of differential equations on two-torus with all phase-lock areas

    NASA Astrophysics Data System (ADS)

    Glutsyuk, Alexey; Rybnikov, Leonid

    2017-01-01

    We consider two-parametric families of non-autonomous ordinary differential equations on the two-torus with coordinates (x, t) of the type \\overset{\\centerdot}{{x}} =v(x)+A+Bf(t) . We study its rotation number as a function of the parameters (A, B). The phase-lock areas are those level sets of the rotation number function ρ =ρ (A,B) that have non-empty interiors. Buchstaber, Karpov and Tertychnyi studied the case when v(x)=\\sin x in their joint paper. They observed the quantization effect: for every smooth periodic function f(t) the family of equations may have phase-lock areas only for integer rotation numbers. Another proof of this quantization statement was later obtained in a joint paper by Ilyashenko, Filimonov and Ryzhov. This implies a similar quantization effect for every v(x)=a\\sin (mx)+b\\cos (mx)+c and rotation numbers that are multiples of \\frac{1}{m} . We show that for every other analytic vector field v(x) (i.e. having at least two Fourier harmonics with non-zero non-opposite degrees and nonzero coefficients) there exists an analytic periodic function f(t) such that the corresponding family of equations has phase-lock areas for all the rational values of the rotation number.

  19. Specific Features of After-School Program Quality: Associations with Children’s Functioning in Middle Childhood

    PubMed Central

    Bolt, Daniel M.; Vandell, Deborah Lowe

    2010-01-01

    This longitudinal study examined associations between three after-school program quality features (positive staff–child relations, available activities, programming flexibility) and child developmental outcomes (reading and math grades, work habits, and social skills with peers) in Grade 2 and then Grade 3. Participants (n = 120 in Grade 2, n = 91 in Grade 3) attended after-school programs more than 4 days per week, on average. Controlling for child and family background factors and children’s prior functioning on the developmental outcomes, positive staff–child relations in the programs were positively associated with children’s reading grades in both Grades 2 and 3, and math grades in Grade 2. Positive staff–child relations also were positively associated with social skills in Grade 2, for boys only. The availability of a diverse array of age-appropriate activities at the programs was positively associated with children’s math grades and classroom work habits in Grade 3. Programming flexibility (child choice of activities) was not associated with child outcomes. PMID:20336364

  20. Simple mechanism whereby the F1-ATPase motor rotates with near-perfect chemomechanical energy conversion

    PubMed Central

    Saita, Ei-ichiro; Suzuki, Toshiharu; Kinosita, Kazuhiko; Yoshida, Masasuke

    2015-01-01

    F1-ATPase is a motor enzyme in which a central shaft γ subunit rotates 120° per ATP in the cylinder made of α3β3 subunits. During rotation, the chemical energy of ATP hydrolysis (ΔGATP) is converted almost entirely into mechanical work by an elusive mechanism. We measured the force for rotation (torque) under various ΔGATP conditions as a function of rotation angles of the γ subunit with quasi-static, single-molecule manipulation and estimated mechanical work (torque × traveled angle) from the area of the function. The torque functions show three sawtooth-like repeats of a steep jump and linear descent in one catalytic turnover, indicating a simple physical model in which the motor is driven by three springs aligned along a 120° rotation angle. Although the second spring is unaffected by ΔGATP, activation of the first spring (timing of the torque jump) delays at low [ATP] (or high [ADP]) and activation of the third spring delays at high [Pi]. These shifts decrease the size and area of the sawtooth (magnitude of the work). Thus, F1-ATPase responds to the change of ΔGATP by shifting the torque jump timing and uses ΔGATP for the mechanical work with near-perfect efficiency. PMID:26195785

  1. Rotational viscometer for high-pressure high-temperature fluids

    DOEpatents

    Carr, Kenneth R.

    1985-01-01

    The invention is a novel rotational viscometer which is well adapted for use with fluids at high temperatures and/or pressures. In one embodiment, the viscometer includes a substantially non-magnetic tube having a closed end and having an open end in communication with a fluid whose viscosity is to be determined. An annular drive magnet is mounted for rotation about the tube. The tube encompasses and supports a rotatable shaft assembly which carries a rotor, or bob, for insertion in the fluid. Affixed to the shaft are (a) a second magnet which is magnetically coupled to the drive magnet and (b) a third magnet. In a typical operation, the drive magnet is rotated to turn the shaft assembly while the shaft rotor is immersed in the fluid. The viscous drag on the rotor causes the shaft assembly to lag the rotation of the drive magnet by an amount which is a function of the amount of viscous drag. A first magnetic pickup generates a waveform whose phase is a function of the angular position of the drive magnet. A second magnetic pickup generates a waveform whose phase is a function of the angular position of the third magnet. An output is generated indicative of the phase difference between the two waveforms.

  2. Sea-Based Automated Launch and Recovery System Virtual Testbed

    DTIC Science & Technology

    2013-12-02

    integrated with an Extended Kalman Filter to study sensor fusion in a fixed wing aircraft shipboard recovery scenario. 15. SUBJECT TERMS...the sensors and filter performance are graded both on pure estimation error, and by examining the touchdown performance of the aircraft on the ship...v, and w body-axis velocity components of the aircraft , while the velocities applied to the extremities are used to calculate estimated rotational

  3. Quantitative comparison of the pivot shift test results before and after anterior cruciate ligament reconstruction by using the three-dimensional electromagnetic measurement system.

    PubMed

    Nagai, Kanto; Hoshino, Yuichi; Nishizawa, Yuichiro; Araki, Daisuke; Matsushita, Takehiko; Matsumoto, Tomoyuki; Takayama, Koji; Nagamune, Kouki; Kurosaka, Masahiro; Kuroda, Ryosuke

    2015-10-01

    Tibial acceleration during the pivot shift test is a potential quantitative parameter to evaluate rotational laxity of anterior cruciate ligament (ACL) insufficiency. However, clinical application of this measurement has not been fully examined. This study aimed to measure and compare tibial acceleration before and after ACL reconstruction (ACLR) in ACL-injured patients. We hypothesized tibial acceleration would be reduced by ACLR and tibial acceleration would be consistent in the same knee at different time points. Seventy ACL-injured patients who underwent ACLR were enrolled. Tibial acceleration during the pivot shift test was measured using an electromagnetic measurement system before ALCR and at the second-look arthroscopy 1 year post-operatively. Tibial acceleration was compared to clinical grading and between ACL-injured/ACL-reconstructed and contralateral knees. Pre-operative tibial acceleration was increased stepwise with the increase in clinical grading (P < 0.01). Tibial acceleration in ACL-injured knee (1.9 ± 1.2 m/s(2)) was larger than that in the contralateral knee (0.8 ± 0.3 m/s(2), P < 0.01), and reduced to 0.9 ± 0.3 m/s(2) post-operatively (P < 0.01). There was no difference between ACL-reconstructed and contralateral knee (n.s.). Tibial acceleration in contralateral knees was consistent pre- and post-operatively (n.s.). Tibial acceleration measurement demonstrated increased rotational laxity in ACL-injured knees and its reduction by ALCR. Additionally, consistent measurements were obtained in ACL-intact knees at different time points. Therefore, tibial acceleration during the pivot shift test could provide quantitative evaluation of rotational stability before and after ACL reconstruction. III.

  4. Effects of Exercise on Spinal Deformities and Quality of Life in Patients with Adolescent Idiopathic Scoliosis

    PubMed Central

    Anwer, Shahnawaz; Alghadir, Ahmad; Abu Shaphe, Md.; Anwar, Dilshad

    2015-01-01

    Objectives. This systematic review was conducted to examine the effects of exercise on spinal deformities and quality of life in patients with adolescent idiopathic scoliosis (AIS). Data Sources. Electronic databases, including PubMed, CINAHL, Embase, Scopus, Cochrane Register of Controlled Trials, PEDro, and Web of Science, were searched for research articles published from the earliest available dates up to May 31, 2015, using the key words “exercise,” “postural correction,” “posture,” “postural curve,” “Cobb's angle,” “quality of life,” and “spinal deformities,” combined with the Medical Subject Heading “scoliosis.” Study Selection. This systematic review was restricted to randomized and nonrandomized controlled trials on AIS published in English language. The quality of selected studies was assessed by the PEDro scale, the Cochrane Collaboration's tool, and the Grading of Recommendations Assessment, Development, and Evaluation System (GRADE). Data Extraction. Descriptive data were collected from each study. The outcome measures of interest were Cobb angle, trunk rotation, thoracic kyphosis, lumbar kyphosis, vertebral rotation, and quality of life. Data Synthesis. A total of 30 studies were assessed for eligibility. Six of the 9 selected studies reached high methodological quality on the PEDro scale. Meta-analysis revealed moderate-quality evidence that exercise interventions reduce the Cobb angle, angle of trunk rotation, thoracic kyphosis, and lumbar lordosis and low-quality evidence that exercise interventions reduce average lateral deviation. Meta-analysis revealed moderate-quality evidence that exercise interventions improve the quality of life. Conclusions. A supervised exercise program was superior to controls in reducing spinal deformities and improving the quality of life in patients with AIS. PMID:26583083

  5. Double Versus Single Tendon Transfers to Improve Shoulder Function in Brachial Plexus Birth Palsy.

    PubMed

    Greenhill, Dustin A; Smith, William R; Ramsey, F V; Kozin, Scott H; Zlotolow, Dan A

    2017-03-27

    In children with brachial plexus birth palsy (BPBP) undergoing tendon transfers to augment shoulder external rotation, it is unclear whether transfer of the latissimus dorsi with its combined latissimus dorsi and teres major (cLT) versus isolated teres major (iTM) tendon transfer yield different outcomes. Records of patients with BPBP who underwent shoulder tendon transfers to augment external rotation were retrospectively reviewed. Transfer type (cLT or iTM) was considered indiscriminate by virtue of surgeon preference. Modified Mallet Scale (mMS) and Active Movement Scale scores were recorded. Patients with <12 months' follow-up, C7 or lower palsy, humeral osteotomy, shoulder procedure(s) within 8 months, microsurgery within 1 year, or recurrent glenohumeral subluxation confirmed by postoperative imaging were excluded. Matched cohorts were identified within each tendon transfer group to yield similar preoperative shoulder function and glenohumeral alignment status. Outcomes for all tendon transfers as well as differences between cLT and iTM cohorts were analyzed. Among 121 cLT and 34 iTM transfers, 49 cLT and 14 iTM met the inclusion criteria. Subsequent matching of cohorts yielded 28 patients (14 cLT and 14 iTM). Average age at time of transfer was 3.0±1.4 years. Follow-up averaged 4.1±3.1 years. There were no statistically significant preoperative differences between cohorts, thus matching criteria were validated. Regardless of tendon(s) transferred, mMS external rotation improved (2.2 to 3.5, P<0.001), whereas mMS internal rotation decreased (3.8 to 3.2, P<0.001). When comparing matched cohorts, cLT transfer produced a greater mMS external rotation improvement than iTM (2.1 vs. 1.5, respectively; P=0.025). Loss of midline function (defined as mMS external rotation <3) occurred in 5 (35.7%) cLT and 2 (14.3%) iTM patients. Both cLT or iTM transfer are effective at augmenting shoulder external rotation in children with C5-C6 BPBP. Furthermore, cLT transfers may yield a larger improvement in external rotation in certain patients. However, both techniques slightly decrease shoulder internal rotation. Given that more total cLT patients lost midline function among matched cohorts, iTM transfer may still be considered when limited midline function is a concern. Level III.

  6. Acoustic wave propagation in continuous functionally graded plates: an extension of the Legendre polynomial approach.

    PubMed

    Lefebvre, J E; Zhang, V; Gazalet, J; Gryba, T; Sadaune, V

    2001-09-01

    The propagation of guided waves in continuous functionally graded plates is studied by using Legendre polynomials. Dispersion curves, and power and field profiles are easily obtained. Our computer program is validated by comparing our results against other calculations from the literature. Numerical results are also given for a graded semiconductor plate. It is felt that the present method could be of quite practical interest in waveguiding engineering, non-destructive testing of functionally graded materials (FGMs) to identify the best inspection strategies, or by means of a numerical inversion algorithm to determine through-thickness gradients in material parameters.

  7. Graft Utilization in the Bridging Reconstruction of Irreparable Rotator Cuff Tears: A Systematic Review.

    PubMed

    Lewington, Matthew R; Ferguson, Devin P; Smith, T Duncan; Burks, Robert; Coady, Catherine; Wong, Ivan Ho-Bun

    2017-11-01

    Rotator cuff tears are one of the most common conditions affecting the shoulder. Because of the difficulty in managing massive rotator cuff tears and the inability of standard techniques to prevent arthropathy, surgeons have developed several novel techniques to improve outcomes and ideally alter the natural history. To systematically review the existing literature and analyze reported outcomes to evaluate the effectiveness of using a bridging graft reconstruction technique to treat large to massive irreparable rotator cuff tears. Systematic review. A systematic search of PubMed, EMBASE, CINAHL, and CENTRAL was employed with the key terms "tear," "allograft," and "rotator cuff." Eligibility was determined by a 3-phase screening process according to the outlined inclusion/exclusion criteria. Data in relation to the primary and secondary outcomes were summarized. The results were synthesized according to the origin of the graft and the level of evidence. Fifteen studies in total were included in this review: 2 comparative studies and 13 observational case series. Both the biceps tendon and the fascia lata autograft groups had significantly superior structural integrity rates on magnetic resonance imaging at 12-month minimum follow-up when compared with their partial primary repair counterparts (58% vs 26%, P = .036; 79% vs 58%, P < .05), respectively. Multiple noncomparative case series investigating allografts, xenografts, and synthetic materials for bridging reconstruction of large to massive rotator cuff tears demonstrated high structural healing rates (74%-90%, 73%-100%, and 60%-90%, respectively). Additionally, both comparative studies and case series demonstrated a general improvement of patients' functional outcome scores. Using a graft for an anatomic bridging rotator cuff repair results in improved function on objective testing and may be functionally better than nonanatomic or partial repair of large to massive rotator cuff tears. Allograft or xenograft techniques appear to be favorable options, given demonstrated functional improvement, imaging-supported graft survival, and lack of harvest complication risk. More high-quality randomized controlled studies are needed to further assess this technique.

  8. Calculation and word problem-solving skills in primary grades - Impact of cognitive abilities and longitudinal interrelations with task-persistent behaviour.

    PubMed

    Jõgi, Anna-Liisa; Kikas, Eve

    2016-06-01

    Primary school math skills form a basis for academic success down the road. Different math skills have different antecedents and there is a reason to believe that more complex math tasks require better self-regulation. The study aimed to investigate longitudinal interrelations of calculation and problem-solving skills, and task-persistent behaviour in Grade 1 and Grade 3, and the effect of non-verbal intelligence, linguistic abilities, and executive functioning on math skills and task persistence. Participants were 864 students (52.3% boys) from 33 different schools in Estonia. Students were tested twice - at the end of Grade1 and at the end of Grade 3. Calculation and problem-solving skills, and teacher-rated task-persistent behaviour were measured at both time points. Non-verbal intelligence, linguistic abilities, and executive functioning were measured in Grade 1. Cross-lagged structural equation modelling indicated that calculation skills depend on previous math skills and linguistic abilities, while problem-solving skills require also non-verbal intelligence, executive functioning, and task persistence. Task-persistent behaviour in Grade 3 was predicted by previous problem-solving skills, linguistic abilities, and executive functioning. Gender and mother's educational level were added as covariates. The findings indicate that math skills and self-regulation are strongly related in primary grades and that solving complex tasks requires executive functioning and task persistence from children. Findings support the idea that instructional practices might benefit from supporting self-regulation in order to gain domain-specific, complex skill achievement. © 2015 The British Psychological Society.

  9. Spatially homogeneous rotating world models.

    NASA Technical Reports Server (NTRS)

    Ozsvath, I.

    1971-01-01

    The mathematical problem encountered when looking for the simplest expanding and rotating model of the universe without the compactness condition for the space sections is formulated. The Lagrangian function is derived for four different rotating universes simultaneously. These models correspond in a certain sense to Godel's (1950) ?symmetric case.'

  10. Functionally graded biomimetic energy absorption concept development for transportation systems.

    DOT National Transportation Integrated Search

    2014-02-01

    Mechanics of a functionally graded cylinder subject to static or dynamic axial loading is considered, including a potential application as energy absorber. The mass density and stiffness are power functions of the radial coordinate as may be the case...

  11. Evaluation and treatment recommendations for acute injuries to the ankle syndesmosis without associated fracture.

    PubMed

    Miller, Timothy L; Skalak, Timothy

    2014-02-01

    Ankle ligamentous injuries are commonly seen in athletes in a variety of sports. Surveys of physicians and trainers of professional sports teams have identified syndesmotic injuries as among the most difficult to treat. In particular, injuries of the ankle syndesmosis have been strongly linked with a prolonged recovery and increased time to return to play. Due to sudden external rotation with the tibiotalar joint in dorsiflexion, these structures are commonly injured in association with fractures of the distal fibula. Surgery is indicated in cases with associated fractures and ligamentous instability, but optimal treatment for syndesmosis injuries without an associated fracture is less clear. A thorough history and physical examination, as well as appropriate imaging, are necessary to effectively diagnose and classify the injury. For stable injuries, short-term immobilization and functional rehabilitation is recommended. Unstable Grade 2 and 3 injuries require surgical fixation. Debate currently exists over rigid screw fixation versus suture button techniques as the ideal fixation method.

  12. Wear of Spur Gears Having a Dithering Motion and Lubricated with a Perfluorinated Polyether Grease

    NASA Technical Reports Server (NTRS)

    Krantz, Timothy; Oswald, Fred; Handschuh, Robert

    2007-01-01

    Gear contact surface wear is one of the important failure modes for gear systems. Dedicated experiments are required to enable precise evaluations of gear wear for a particular application. The application of interest for this study required evaluation of wear of gears lubricated with a grade 2 perfluorinated polyether grease and having a dithering (rotation reversal) motion. Experiments were conducted using spur gears made from AISI 9310 steel. Wear was measured using a profilometer at test intervals encompassing 10,000 to 80,000 cycles of dithering motion. The test load level was 1.1 GPa maximum Hertz contact stress at the pitch-line. The trend of total wear as a function of test cycles was linear, and the wear depth rate was approximately 1.2 nm maximum wear depth per gear dithering cycle. The observed wear rate was about 600 times greater than the wear rate for the same gears operated at high speed and lubricated with oil.

  13. Calculation of spherical harmonics and Wigner d functions by FFT. Applications to fast rotational matching in molecular replacement and implementation into AMoRe.

    PubMed

    Trapani, Stefano; Navaza, Jorge

    2006-07-01

    The FFT calculation of spherical harmonics, Wigner D matrices and rotation function has been extended to all angular variables in the AMoRe molecular replacement software. The resulting code avoids singularity issues arising from recursive formulas, performs faster and produces results with at least the same accuracy as the original code. The new code aims at permitting accurate and more rapid computations at high angular resolution of the rotation function of large particles. Test calculations on the icosahedral IBDV VP2 subviral particle showed that the new code performs on the average 1.5 times faster than the original code.

  14. Socioeconomic inequalities in physical and mental functioning of Japanese civil servants: explanations from work and family characteristics.

    PubMed

    Sekine, Michikazu; Chandola, Tarani; Martikainen, Pekka; Marmot, Michael; Kagamimori, Sadanobu

    2006-07-01

    Poor physical and mental functioning is more common among people of low socioeconomic status (SES) and those with disadvantaged work and family characteristics. This study aims to clarify whether the SES inequalities in functioning can be explained by the SES differences in work and family characteristics. The subjects were 3787 male and female civil servants, aged 20-65, working in a local government on the west coast of Japan. Logistic regression analysis was performed to examine (1) whether there were employment-grade (SES) differences in poor physical and mental functioning as measured by the Short Form 36 (SF-36) and (2) whether these SES differences were explained by work and family characteristics. In general, low control at work, high demands, low social support, short and long work hours, shift work, being unmarried, high family-to-work conflict and high work-to-family conflict were independently associated with poor physical and mental functioning in both men and women. In men, the age-adjusted odds ratio (OR) of low-grade employees for poor physical functioning was 1.93 (95% confidence interval: 1.38-2.69) in comparison to high-grade employees. The grade difference was mildly attenuated, when adjusted for work and family characteristics (OR = 1.72)(1.20-2.47). The age-adjusted OR of the low-grade employees for poor mental functioning was 1.88 (1.29-2.74). The grade difference was attenuated and no longer significant when adjusted for work and family characteristics (OR = 1.51)(0.99-2.31). Among women, there were no significant grade-differences in poor physical and mental functioning. Although longitudinal research is necessary to clarify the causal nature of these associations, improvements in SES differences in work and family characteristics may be important for reducing SES inequalities in physical and mental functioning among Japanese men. The different patterns of SES inequalities in health between men and women deserve further research.

  15. Measurement of vertebral rotation: Perdriolle versus Raimondi.

    PubMed

    Weiss, H R

    1995-01-01

    The measurement of vertebral rotation according to Perdriolle is widely used in the French-speaking and Anglo-American countries. Even in this measurement technique there may be a relatively high estimation error because of the not very accurate grading in steps of 5 degrees. The measurement according to Raimondi seems to be easier to use and is more accurate, with 2 degrees steps. The purpose of our study was to determine the technical error of both measuring methods. The apex vertebra of 40 curves on 20 anteroposterior (AP) radiographs were measured by using the Perdriolle torsion meter and the Regolo Raimondi. Interrater and intrarater reliability were computed. The thoracic Cobb angle was 43 degrees, the lumbar Cobb angle 36 degrees. The average rotation according to Perdriolle was 19.1 degrees thoracic (SD 11.14), 12.7 degrees lumbar (11.21). Measurement of vertebral rotation according to Raimondi showed an average rotation of 20.25 degrees in the thoracic region (11.40) and 13.4 degrees lumbar (10.92). The intrarater reliability was r = 0.991 (Perdriolle) and r = 0.997 (Raimondi). The average intrarater error was 1.025 degrees in the Perdriolle measurement and 0.4 degrees in the Raimondi measurement. Interrater error was on average 3.112 degrees for the Perdriolle measurement and 3.630 degrees for the Raimondi measurement. This shows that both methods are useful tools for the follow-up of vertebral rotation as projected on standard X-rays for the experienced clinical. The Raimondi ruler is easier to use and is slightly more reliable.

  16. Computation of turbulent rotating channel flow with an algebraic Reynolds stress model

    NASA Technical Reports Server (NTRS)

    Warfield, M. J.; Lakshminarayana, B.

    1986-01-01

    An Algebraic Reynolds Stress Model has been implemented to modify the Kolmogorov-Prandtl eddy viscosity relation to produce an anisotropic turbulence model. The eddy viscosity relation becomes a function of the local turbulent production to dissipation ratio and local turbulence/rotation parameters. The model is used to predict fully-developed rotating channel flow over a diverse range of rotation numbers. In addition, predictions are obtained for a developing channel flow with high rotation. The predictions are compared with the experimental data available. Good predictions are achieved for mean velocity and wall shear stress over most of the rotation speeds tested. There is some prediction breakdown at high rotation (rotation number greater than .10) where the effects of the rotation on turbulence become quite complex. At high rotation and low Reynolds number, the laminarization on the trailing side represents a complex effect of rotation which is difficult to predict with the described models.

  17. A Progression in First-Grade Children's Thinking about Variable and Variable Notation in Functional Relationships

    ERIC Educational Resources Information Center

    Blanton, Maria; Brizuela, Bárbara M.; Gardiner, Angela Murphy; Sawrey, Katie; Newman-Owens, Ashley

    2017-01-01

    Recent research suggests that children in elementary grades have some facility with variable and variable notation in ways that warrant closer attention. We report here on an empirically developed progression in first-grade children's thinking about these concepts in functional relationships. Using learning trajectories research as a framework for…

  18. An anatomically based protocol for the description of foot segment kinematics during gait.

    PubMed

    Leardini, A; Benedetti, M G; Catani, F; Simoncini, L; Giannini, S

    1999-10-01

    To design a technique for the in vivo description of ankle and other foot joint rotations to be applied in routine functional evaluation using non-invasive stereophotogrammetry. Position and orientation of tibia/fibula, calcaneus, mid-foot, 1st metatarsal and hallux segments were tracked during the stance phase of walking in nine asymptomatic subjects. Rigid clusters of reflective markers were used for foot segment pose estimation. Anatomical landmark calibration was applied for the reconstruction of anatomical landmarks. Previous studies have analysed only a limited number of joints or have proposed invasive techniques. Anatomical landmark trajectories were reconstructed in the laboratory frame using data from the anatomical calibration procedure. Anatomical co-ordinate frames were defined using the obtained landmark trajectories. Joint co-ordinate systems were used to calculate corresponding joint rotations in all three anatomical planes. The patterns of the joint rotations were highly repeatable within subjects. Consistent patterns between subjects were also exhibited at most of the joints. The method proposed enables a detailed description of ankle and other foot joint rotations on an anatomical base. Joint rotations can therefore be expressed in the well-established terminology necessary for their clinical interpretation. Functional evaluation of patients affected by foot diseases has recently called for more detailed and non-invasive protocols for the description of foot joint rotations during gait. The proposed method can help clinicians to distinguish between normal and pathological pattern of foot joint rotations, and to quantitatively assess the restoration of normal function after treatment.

  19. Arthroscopic Rotator Cuff Repair With Graft Augmentation of 3-Dimensional Biological Collagen for Moderate to Large Tears: A Randomized Controlled Study.

    PubMed

    Cai, You-Zhi; Zhang, Chi; Jin, Ri-Long; Shen, Tong; Gu, Peng-Cheng; Lin, Xiang-Jin; Chen, Jian-De

    2018-05-01

    Due to the highly organized tissue and avascular nature of the rotator cuff, rotator cuff tears have limited ability to heal after the tendon is reinserted directly on the greater tubercle of the humerus. Consequently, retears are among the most common complications after rotator cuff repair. Augmentation of rotator cuff repairs with patches has been an active area of research in recent years to reduce retear rate. Graft augmentation with 3D collagen could prevent retears of the repaired tendon and improve tendon-bone healing in moderate to large rotator cuff tears. Randomized controlled study; Level of evidence, 2. A prospective, randomized controlled study was performed in a consecutive series of 112 patients age 50 to 85 years who underwent rotator cuff repair with the suture-bridge technique (58 patients, control group) or the suture-bridge technique augmented with 3-dimensional (3D) collagen (54 patients, study group). All patients were followed for 28.2 months (range, 24-36 months). Visual analog scale score for pain, University of California Los Angeles (UCLA) shoulder score, and Constant score were determined. Magnetic resonance imaging was performed pre- and postoperatively (at a minimum of 24 months) to evaluate the integrity of the rotator cuff and the retear rate of the repaired tendon. Three patients in each group had biopsies at nearly 24 months after surgery with histological assessment and transmission electron microscopy. A total of 104 patients completed the final follow-up. At the 12-month follow-up, the UCLA shoulder score was 28.1 ± 1.9 in the study group, which was significantly better than that in the control group (26.9 ± 2.1, P = .002). The Constant score was also significantly better in the study group (87.1 ± 3.2) than in the control group (84.9 ± 4.2, P = .003). However, at the final follow-up, no significant differences were found in the UCLA shoulder scores (29.4 ± 1.9 in the control group and 30.0 ± 1.6 in the study group, P = .052) or Constant scores (89.9 ± 3.2 in the control group and 90.8 ± 3.5 in the study group, P = .18). In terms of structural integrity, more patients in the study group had a favorable type I retear grade (18/51) than in the control group (10/53) ( P = .06). The postoperative retear rate was 34.0% in the control group and 13.7% in the study group, thus indicating a significantly lower retear rate in the study group ( P = .02). Biopsy specimens of the tendon-bone interface in 6 patients revealed more bone formation and more aligned fibers with larger diameters in the study group than in the control group. No intraoperative or postoperative complications were noted in either group. 3D collagen augmentation could provide effective treatment of moderate to large rotator cuff tears, providing substantial functional improvement, and could reduce the retear rate. This technique could also promote new tendon-bone formation, thus exerting a prominent effect on tendon-bone healing.

  20. Functional and structural outcomes of single-row versus double-row versus combined double-row and suture-bridge repair for rotator cuff tears.

    PubMed

    Mihata, Teruhisa; Watanabe, Chisato; Fukunishi, Kunimoto; Ohue, Mutsumi; Tsujimura, Tomoyuki; Fujiwara, Kenta; Kinoshita, Mitsuo

    2011-10-01

    Although previous biomechanical research has demonstrated the superiority of the suture-bridge rotator cuff repair over double-row repair from a mechanical point of view, no articles have described the structural and functional outcomes of this type of procedure. The structural and functional outcomes after arthroscopic rotator cuff repair may be different between the single-row, double-row, and combined double-row and suture-bridge (compression double-row) techniques. Cohort study; Level of evidence, 3. There were 206 shoulders in 201 patients with full-thickness rotator cuff tears that underwent arthroscopic rotator cuff repair. Eleven patients were lost to follow-up. Sixty-five shoulders were repaired using the single-row, 23 shoulders using the double-row, and 107 shoulders using the compression double-row techniques. Clinical outcomes were evaluated at an average of 38.5 months (range, 24-74 months) after rotator cuff repair. Postoperative cuff integrity was determined using Sugaya's classification of magnetic resonance imaging (MRI). The retear rates after arthroscopic rotator cuff repair were 10.8%, 26.1%, and 4.7%, respectively, for the single-row, double-row, and compression double-row techniques. In the subcategory of large and massive rotator cuff tears, the retear rate in the compression double-row group (3 of 40 shoulders, 7.5%) was significantly less than those in the single-row group (5 of 8 shoulders, 62.5%, P < .001) and the double-row group (5 of 12 shoulders, 41.7%, P < .01). Postoperative clinical outcomes in patients with a retear were significantly lower than those in patients without a retear for all 3 techniques. The additional suture bridges decreased the retear rate for large and massive tears. The combination of the double-row and suture-bridge techniques, which had the lowest rate of postoperative retear, is an effective option for arthroscopic repair of the rotator cuff tendons because the postoperative functional outcome in patients with a retear is inferior to that without retear.

  1. Experience with k-epsilon turbulence models for heat transfer computations in rotating

    NASA Technical Reports Server (NTRS)

    Tekriwal, Prabbat

    1995-01-01

    This viewgraph presentation discusses geometry and flow configuration, effect of y+ on heat transfer computations, standard and extended k-epsilon turbulence model results with wall function, low-Re model results (the Lam-Bremhorst model without wall function), a criterion for flow reversal in a radially rotating square duct, and a summary.

  2. Altered functional brain asymmetry for mental rotation: effect of estradiol changes across the menstrual cycle.

    PubMed

    Zhu, Xun; Kelly, Thomas H; Curry, Thomas E; Lal, Chitra; Joseph, Jane E

    2015-09-30

    Mental rotation is a visuospatial task associated with pronounced sex differences. Performance is also affected by gonadal hormones such as testosterone and estradiol. To better understand hormonal modulation of the neural substrates of mental rotation, the present study examined the influence of estradiol using functional MRI. Ten premenopausal women were tested on a 3D mental rotation task during the early follicular and late follicular phases of the menstrual cycle. Change in estradiol between the two phases was confirmed by hormone assays. Brain activation patterns were similar across the two phases, but the change in estradiol had different associations with the two hemispheres. Better performance in the late follicular than the early follicular phase was associated with a pattern of reduced recruitment of the right hemisphere and increased recruitment of the left hemisphere. The increased recruitment of the left hemisphere was directly associated with greater changes in estradiol. Given that the right hemisphere is the dominant hemisphere in visuospatial processing, our results suggest that estradiol is associated with reduced functional asymmetry, consistent with recent accounts of hormonal modulation of neurocognitive function.

  3. Thermo-Electro-Mechanical Analysis of a Curved Functionally Graded Piezoelectric Actuator with Sandwich Structure.

    PubMed

    Yan, Zhi; Zaman, Mostafa; Jiang, Liying

    2011-12-12

    In this work, the problem of a curved functionally graded piezoelectric (FGP) actuator with sandwich structure under electrical and thermal loads is investigated. The middle layer in the sandwich structure is functionally graded with the piezoelectric coefficient g 31 varying continuously along the radial direction of the curved actuator. Based on the theory of linear piezoelectricity, analytical solutions are obtained by using Airy stress function to examine the effects of material gradient and heat conduction on the performance of the curved actuator. It is found that the material gradient and thermal load have significant influence on the electroelastic fields and the mechanical response of the curved FGP actuator. Without the sacrifice of actuation deflection, smaller internal stresses are generated by using the sandwich actuator with functionally graded piezoelectric layer instead of the conventional bimorph actuator. This work is very helpful for the design and application of curved piezoelectric actuators under thermal environment.

  4. Design and testing of a rotational brake with shear thickening fluids

    NASA Astrophysics Data System (ADS)

    Tian, Tongfei; Nakano, Masami

    2017-03-01

    A rotational brake working with shear thickening fluid (STF) was designed and tested in this study. With the optimisation in design, most of the STF in the brake can receive the same shear rate when the brake rotates. The parts of this brake were fabricated with a 3D printer and then assembled manually. Three types of STFs with various carrier fluids and different particles were fabricated and tested with a rheometer. Then the brake with each STF was separately tested with the rheometer. The estimated and measured torques as a function of the angular velocity fit each other well. The stability of the rotational STF brake was investigated in repeated tests, which proved the function of the brake for a long time.

  5. Exploring Novel Spintronic Responses from Advanced Functional Organic Materials

    DTIC Science & Technology

    2015-08-13

    optical properties of different organic molecules, mesogenics and conjugated polymers, mainly poly(3-alkylthiophene)s, have been investigated by Faraday ...of organic media we focused in our part of the project on studies of the Faraday rotation of an array of organic molecules and conjugated polymers...difficult to measure. However, χeem is easy accessible from Faraday rotation measurements. Faraday rotation, the rotation of the plane of polarization

  6. New approach to evaluate rotation of cervical vertebrae

    NASA Astrophysics Data System (ADS)

    Hahn, Matthias

    2001-07-01

    Functional deficits after whiplash injury can be analyzed with a quite novel radiologic method by examination of joint-blocks in C0/1 and C1/2. Thereto the movability of C0, C1 and C2 is determined with three spiral CT-scans of the patient's cervical spine. One series in neutral and one in maximal active lateral right and left rotation each. Previous methods were slice based and time consuming when manually evaluated. We propose a new approach to a computation of these angles in 3D. After a threshold segmentation of bone tissue, a rough 2D classification takes place for C0, C1 and C2 in each rotation series. The center of an axial rotation for each vertebra is gained from the approximation of its center of gravity. The rotation itself is estimated by a cross-correlation of the radial distance functions. From the previous rotation the results are taken to initialize a 3D matching algorithm based on the sum of squared differences in intensity. The optimal match of the vertebrae is computed by means of the multidimensional Powell minimization algorithm. The three translational and three rotational components build a six-dimensional search-space. The vertebrae detection and rotation computation is done fully automatic.

  7. Reaching the limits of mandated self-reporting: clinical logbooks do not predict clerkship performance.

    PubMed

    Huang, Grace C; Almeida, Jacqueline M; Roberts, David H

    2012-01-01

    Logbooks are used by US medical schools to evaluate curricular objectives and meet accreditation requirements, but research supporting their utility is conflicting. The goal of our study was to examine the relationship between volume of clinical rotation experiences as reported in a logbook and clerkship grades within a longitudinal integrated clerkship. We conducted a retrospective cohort study of third-year (clinical) medical students during academic year 2008-2009. We tracked student entries in a pocket-sized logbook (number of clinical encounters per clerkship, total number of exams, and procedures over the academic year). We performed correlation analyses between logbook entries and clerkship grades. We enrolled 36 students, who reported a total of 2992 encounters, 2262 exams, and 2342 procedures. Correlation coefficients between volume of clinical experience and clerkship grades were less than 0.4, indicating low correlation. We found borderline statistical significance for the Neurology, OB/Gyn, and Surgery clerkships. Sensitivity analyses showed little correlation between low-reporting activity and clerkship grades. Even within an integrated longitudinal clerkship framework, our findings are consistent with previous studies showing a negligible relationship between logbooks as an educational process measure and how they relate to educational outcomes.

  8. Is the Sky Falling? Grade Inflation and the Signaling Power of Grades

    ERIC Educational Resources Information Center

    Pattison, Evangeleen; Grodsky, Eric; Muller, Chandra

    2013-01-01

    Grades are the fundamental currency of our educational system; they signal academic achievement and noncognitive skills to parents, employers, postsecondary gatekeepers, and students themselves. Grade inflation compromises the signaling value of grades and undermines their capacity to achieve the functions for which they are intended. We challenge…

  9. The inaccuracy of surface-measured model-derived tibiofemoral kinematics.

    PubMed

    Li, Kang; Zheng, Liying; Tashman, Scott; Zhang, Xudong

    2012-10-11

    This study assessed the accuracy of surface-measured OpenSim-derived tibiofemoral kinematics in functional activities. Ten subjects with unilateral, isolated grade II PCL deficiency performed level running and stair ascent. A dynamic stereo radiography (DSX) system and a Vicon motion capture system simultaneously measured their knee or lower extremity movement. Surface marker motion data from the Vicon system were used to create subject-specific models in OpenSim and derive the tibiofemoral kinematics. The surface-measured model-derived tibiofemoral kinematics in all six degrees of freedom (DOFs) were then compared with those measured by the DSX as the benchmarks. The differences between surface- and DSX-measured tibiofemoral kinematics were found to be substantial: the overall mean (±SD) RMS differences during running were 9.1±3.2°, 2.0±1.2°, and 6.4±4.5° for the flexion-extension, abduction-adduction, and internal-external rotations, respectively, and 7.1±3.2 mm, 8.8±3.7 mm, and 1.9±1.2 mm for anterior-posterior, proximal-distal, and medial-lateral translations, respectively. The differences were more pronounced in relatively higher speed running than in stair ascent. It was also found that surface-based measures significantly underestimated the mean as well as inter-subject variability of the differences between PCL-injured and intact knees in abduction-adduction, internal-external rotations, and anterior-posterior translation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review.

    PubMed

    DeHaan, Alexander M; Axelrad, Thomas W; Kaye, Elizabeth; Silvestri, Lorenzo; Puskas, Brian; Foster, Timothy E

    2012-05-01

    The advantage of single-row versus double-row arthroscopic rotator cuff repair techniques has been a controversial issue in sports medicine and shoulder surgery. There is biomechanical evidence that double-row techniques are superior to single-row techniques; however, there is no clinical evidence that the double-row technique provides an improved functional outcome. When compared with single-row rotator cuff repair, double-row fixation, although biomechanically superior, has no clinical benefit with respect to retear rate or improved functional outcome. Systematic review. The authors reviewed prospective studies of level I or II clinical evidence that compared the efficacy of single- and double-row rotator cuff repairs. Functional outcome scores included the American Shoulder and Elbow Surgeons (ASES) shoulder scale, the Constant shoulder score, and the University of California, Los Angeles (UCLA) shoulder rating scale. Radiographic failures and complications were also analyzed. A test of heterogeneity for patient demographics was also performed to determine if there were differences in the patient profiles across the included studies. Seven studies fulfilled our inclusion criteria. The test of heterogeneity across these studies showed no differences. The functional ASES, Constant, and UCLA outcome scores revealed no difference between single- and double-row rotator cuff repairs. The total retear rate, which included both complete and partial retears, was 43.1% for the single-row repair and 27.2% for the double-row repair (P = .057), representing a trend toward higher failures in the single-row group. Through a comprehensive literature search and meta-analysis of current arthroscopic rotator cuff repairs, we found that the single-row repairs did not differ from the double-row repairs in functional outcome scores. The double-row repairs revealed a trend toward a lower radiographic proven retear rate, although the data did not reach statistical significance. There may be a concerning trend toward higher retear rates in patients undergoing a single-row repair, but further studies are required.

  11. Comparing the Effectiveness of Sagittal Balance, Foraminal Stenosis, and Preoperative Cord Rotation in Predicting Postoperative C5 Palsy.

    PubMed

    Chugh, Arunit J S; Weinberg, Douglas S; Alonso, Fernando; Eubanks, Jason D

    2017-11-01

    Retrospective cohort review. To determine whether preoperative cord rotation is independently correlated with C5 palsy when analyzed alongside measures of sagittal balance and foraminal stenosis. Postoperative C5 palsy is a well-documented complication of cervical procedures with a prevalence of 4%-8%. Recent studies have shown a correlation with preoperative spinal cord rotation. There have been few studies, however, that have examined the role of sagittal balance and foraminal stenosis in the development of C5 palsy. A total of 77 patients who underwent cervical decompression-10 of whom developed C5 palsy-were reviewed. Sagittal balance was assessed using curvature angle and curvature index on radiographs and magnetic resonance image (MRI). Cord rotation was assessed on axial MRI. C4-C5 foraminal stenosis was assessed on sagittal MRI using area measurements and a grading scale. Demographics and information on surgical approach were gathered from chart review. Correlation with C5 palsy was performed by point-biserial, χ, and regression analyses. Point-biserial analysis indicated that only cord rotation showed significance (P<0.01). There was no statistical significance shown with surgical approach, sex, or age. In addition, changes in sagittal balance did not correlate with presence of C5 palsy. Logistic regression model yielded cord rotation as the only significant independent predictor of C5 palsy. For every degree of axial cord rotation, the likelihood ratio for suffering a C5 palsy was 3.93 (95% confidence interval, 2.01-8.66; P<0.05). This supports the independent capability of preoperative cord rotation to predict postoperative C5 palsy. Lack of correlation with measures of neuroforaminal stenosis potentially points to mechanisms other than direct compression as the etiology. In addition, the lack of correlation with postoperative changes in sagittal balance hints that measures of curvature angle and curvature index may not be appropriate to accurately predict this complication. Level 3.

  12. Surgical correction of shoulder rotation deformity in brachial plexus birth palsy: long-term results in 118 patients.

    PubMed

    Hultgren, T; Jönsson, K; Roos, F; Järnbert-Pettersson, H; Hammarberg, H

    2014-10-01

    We present the long-term results of open surgery for internal shoulder rotational deformity in brachial plexus birth palsy (BPBP). From 1997 to 2005, 207 patients (107 females, 100 males, mean age 6.2 (0.6 to 34)) were operated on with subscapularis elongation and/or latissimus dorsi to infraspinatus transfer. Incongruent shoulder joints were relocated. The early results of these patients has been reported previously. We analysed 118 (64 females, 54 males, mean age 15.1 (7.6 to 34)) of the original patient cohort at a mean of 10.4 years (7.0 to 15.1) post-operatively. A third of patients with relocated joints had undergone secondary internal rotational osteotomy of the humerus. A mixed effects models approach was used to evaluate the effects of surgery on shoulder rotation, abduction, and the Mallet score. Independent factors were time (pre-and post-surgery), gender, age, joint category (congruent, relocated, relocated plus osteotomy) and whether or not a transfer had been performed. Data from a previously published short-term evaluation were reworked in order to obtain pre-operative values. The mean improvement in external rotation from pre-surgery to the long-term follow-up was 66.5° (95% confidence interval (CI) 61.5 to 71.6). The internal rotation had decreased by a mean of 22.6° (95% CI -18.7 to -26.5). The mean improvement in the three-grade aggregate Mallet score was 3.1 (95% CI 2.7 to 3.4), from 8.7 (95% CI 8.4 to 9.0) to 11.8 (11.5 to 12.1). Our results show that open subscapularis elongation achieves good long-term results for patients with BPBP and an internal rotation contracture, providing lasting joint congruency and resolution of the trumpet sign, but with a moderate mean loss of internal rotation. ©2014 The British Editorial Society of Bone & Joint Surgery.

  13. Nursing students practice primary fire prevention.

    PubMed

    Lehna, Carlee; Todd, Julie A; Keller, Rachel; Presley, Lynn; Jackson, Jessica; Davis, Stephanie; Hockman, Kristi; Phillips-Payne, Charles; Sauer, Sarah; Wessemeier, Sarah

    2013-09-01

    The purpose of this project was to evaluate a standardized, interactive, home fire safety program for elementary school students. Senior baccalaureate nursing students in their pediatric clinical rotation taught burn prevention techniques using Hazard House, a model house filled with common household fire hazards (Hazard House, 2006, Ref. 1). Elementary school students were encouraged to identify the hazards and discuss ways in which the house could be made safer. Local firemen then briefly presented what to do if a fire occurred, how firemen may look during a rescue, and the importance of working smoke alarms in the home. A pretest-posttest design was used to examine the effectiveness of an educational intervention. The three groups of participants included 128 kindergarten students, 311 students in grades 1-2, and 61 students in grades 3-4. The tests and interventions were tailored appropriately for each age group. There was no difference in pre- and post-test scores for the students in kindergarten and grades 3-4 (p>0.05). However, there was a significant difference for students in grades 1-2 (p<0.001). It is important for nurses to assess for and teach about fire injury prevention to prevent potentially devastating irreversible injuries. The results suggest that the educational intervention was effective in improving the understanding of fire safety for students in grades 1-2. Future studies may need to include a larger sample of students for the other grades. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  14. Acute effects of scapular mobilization in shoulder dysfunction: a double-blind randomized placebo-controlled trial.

    PubMed

    Surenkok, Ozgur; Aytar, Aydan; Baltaci, Gul

    2009-11-01

    The aim of this study was to evaluate the initial effects of scapular mobilization (SM) on shoulder range of motion (ROM), scapular upward rotation, pain, and function. Pretest-posttest for 3 groups (SM, sham, and control). A double-blinded, randomized, placebo-controlled trial was conducted to evaluate the initial effect of the SM at a sports physiotherapy clinic. 39 subjects (22 women, 17 men; mean age 54.30 +/- 14.16 y, age range 20-77 y). A visual analog scale, ROM, scapular upward rotation, and function were assessed before and just after SM. SM (n = 13) consisted of the application of superoinferior gliding, rotations, and distraction to the scapula. The sham (n = 13) condition replicated the treatment condition except for the hand positioning. The control group (n = 13) did not undergo any physiotherapy and rehabilitation program. Pain severity was assessed with a visual analog scale. Scapular upward rotation was measured with a baseline digital inclinometer. Constant Shoulder Score (CSS) was used to measure shoulder function. After SM, we found significant improvements for shoulder ROM, scapular upward rotation, and CSS between pretreatment and posttreatment compared with the sham and control groups. In the sham group, shoulder-ROM values increased or decreased for the shoulder and scapular upward rotation was not changed. Pain, ROM, and physical function of the shoulder were not significantly different in the sham group than in controls (P > .05). SM may be a useful manual therapy technique to apply to participants with a painful limitation of the shoulder. SM increases ROM and decreases pain intensity.

  15. The Correlation between the Fourth Grade Students' Level of Functional Literacy and Metacognitive Awareness

    ERIC Educational Resources Information Center

    Özenç, Emine Gül; Dikici, Hidayet

    2016-01-01

    The present study aims at presenting the relationship between the fourth grade primary school students' level of functional literacy and metacognitive awareness. The study group of the research is made up of 406 fourth grade students attending school during 2015-2016 academic year in Nigde. This study adopts survey model and its data collection…

  16. LEARNING EFFICIENCY AS A FUNCTION OF DEPICTION, VERBALIZATION, GRADE AND SOCIAL CLASS.

    ERIC Educational Resources Information Center

    ROHWER, WILLIAM D., JR.; AND OTHERS

    LEARNING EFFICIENCY AS A FUNCTION OF DEPICTION, VERBALIZATION, GRADE LEVEL, AND SOCIAL CLASS WAS EXPLORED BY ASKING 384 KINDERGARTEN, FIRST-, THIRD-, AND SIXTH-GRADE CHILDREN FROM BOTH MIDDLE-CLASS AND LOWER-CLASS AREAS TO LEARN A LIST OF 24 PAIRED ASSOCIATES. ALL PAIRS WERE PRESENTED PICTORIALLY BY A STUDY-TEST METHOD FOR TWO LEARNING TRIALS. THE…

  17. Concomitant glenohumeral pathologies associated with acute and chronic grade III and grade V acromioclavicular joint injuries.

    PubMed

    Jensen, Gunnar; Millett, Peter J; Tahal, Dimitri S; Al Ibadi, Mireille; Lill, Helmut; Katthagen, Jan Christoph

    2017-08-01

    The purpose of this study was to identify the risk of concomitant glenohumeral pathologies with acromioclavicular joint injuries grade III and V. Patients who underwent arthroscopically-assisted stabilization of acromioclavicular joint injuries grade III or grade V between 01/2007 and 12/2015 were identified in the patient databases of two surgical centres. Gender, age at index surgery, grade of acromioclavicular joint injury (Rockwood III or Rockwood V), and duration between injury and index surgery (classified as acute or chronic) were of interest. Concomitant glenohumeral pathologies were noted and their treatment was classified as debridement or reconstructive procedure. A total of 376 patients (336 male, 40 female) were included. Mean age at time of arthroscopic acromioclavicular joint reconstruction surgery was 42.1 ± 14.0 years. Overall, 201 patients (53%) had one or more concomitant glenohumeral pathologies. Lesions of the biceps tendon complex and rotator cuff were the most common. Forty-five patients (12.0%) had concomitant glenohumeral pathologies that required an additional repair. The remaining 156 patients (41.5%) received a debridement of their concomitant pathologies. Rockwood grade V compared to Rockwood grade III (p = 0.013; odds ratio 1.7), and chronic compared to acute injury were significantly associated with having a concomitant glenohumeral pathology (p = 0.019; odds ratio 1.7). The probability of having a concomitant glenohumeral pathology was also significantly associated with increasing age (p < 0.0001). Concomitant glenohumeral pathologies were observed in 53% of surgically treated patients with an acute or chronic acromioclavicular joint injury of either grade III or V. Twenty-two percent of these patients with concomitant glenohumeral pathologies received an additional dedicated repair procedure. Although a significant difference in occurrence of concomitant glenohumeral pathologies was seen between Rockwood grades III and V, and between acute and chronic lesions, increasing age was identified as the most dominant predictor. Level IV, case series.

  18. The Association Between Sleep Disordered Breathing, Academic Grades, and Cognitive and Behavioral Functioning Among Overweight Subjects During Middle to Late Childhood

    PubMed Central

    Beebe, Dean W.; Ris, M. Douglas; Kramer, Megan E.; Long, Elizabeth; Amin, Raouf

    2010-01-01

    Study Objectives: (1) to determine the associations of sleep disordered breathing (SDB) with behavioral functioning, cognitive test scores, and school grades during middle- to late-childhood, an under-researched developmental period in the SDB literature, and (2) to clarify whether associations between SDB and school grades are mediated by deficits in cognitive or behavioral functioning. Design: Cross-sectional correlative study. Setting: Office/hospital, plus reported functioning at home and at school. Participants: 163 overweight subjects aged 10-16.9 years were divided into 4 groups based upon their obstructive apnea+hypopnea index (AHI) during overnight polysomnography and parent report of snoring: Moderate-Severe OSA (AHI > 5, n = 42), Mild OSA (AHI = 1-5, n = 58), Snorers (AHI < 1 + snoring, n = 26), and No SDB (AHI < 1 and nonsnoring, n = 37). Measurements: Inpatient overnight polysomnography, parent- and self-report of school grades and sleep, parent- and teacher-report of daytime behaviors, and office-based neuropsychological testing. Results: The 4 groups significantly differed in academic grades and parent- and teacher-reported behaviors, particularly inattention and learning problems. These findings remained significant after adjusting for subject sex, race, socioeconomic status, and school night sleep duration. Associations with SDB were confined to reports of behavioral difficulties in real-world situations, and did not extend to office-based neuropsychological tests. Findings from secondary analyses were consistent with, but could not definitively confirm, a causal model in which SDB affects school grades via its impact on behavioral functioning. Conclusions: SDB during middle- to late-childhood is related to important aspects of behavioral functioning, especially inattention and learning difficulties, that may result in significant functional impairment at school. Citation: Beebe DW; Ris MD; Kramer ME; Long E; Amin R. The association between sleep disordered breathing, academic grades, and cognitive and behavioral functioning among overweight subjects during middle to late childhood. SLEEP 2010;33(11):1447-1456. PMID:21102986

  19. Electric dipole moment function of the X1 Sigma/+/ state of CO - Vibration-rotation matrix elements for transitions of gas laser and astrophysical interest

    NASA Technical Reports Server (NTRS)

    Chackerian, C., Jr.

    1976-01-01

    The electric dipole moment function of the ground electronic state of carbon monoxide has been determined by combining numerical solutions of the radial Schrodinger equation with absolute intensity data of vibration-rotation bands. The derived dipole moment function is used to calculate matrix elements of interest to stellar astronomy and of importance in the carbon monoxide laser.

  20. Correlation between hip function and knee kinematics evaluated by three-dimensional motion analysis during lateral and medial side-hopping.

    PubMed

    Itoh, Hiromitsu; Takiguchi, Kohei; Shibata, Yohei; Okubo, Satoshi; Yoshiya, Shinichi; Kuroda, Ryosuke

    2016-09-01

    [Purpose] Kinematic and kinetic characteristics of the limb during side-hopping and hip/knee interaction during this motion have not been clarified. The purposes of this study were to examine the biomechanical parameters of the knee during side hop and analyze its relationship with clinical measurements of hip function. [Subjects and Methods] Eleven male college rugby players were included. A three-dimensional motion analysis system was used to assess motion characteristics of the knee during side hop. In addition, hip range of motion and muscle strength were evaluated. Subsequently, the relationship between knee motion and the clinical parameters of the hip was analyzed. [Results] In the lateral touchdown phase, the knee was positioned in an abducted and externally rotated position, and increasing abduction moment was applied to the knee. An analysis of the interaction between knee motion and hip function showed that range of motion for hip internal rotation was significantly correlated with external rotation angle and external rotation/abduction moments of the knee during the lateral touchdown phase. [Conclusion] Range of motion for hip internal rotation should be taken into consideration for identifying the biomechanical characteristics in the side hop test results.

  1. Correlation between hip function and knee kinematics evaluated by three-dimensional motion analysis during lateral and medial side-hopping

    PubMed Central

    Itoh, Hiromitsu; Takiguchi, Kohei; Shibata, Yohei; Okubo, Satoshi; Yoshiya, Shinichi; Kuroda, Ryosuke

    2016-01-01

    [Purpose] Kinematic and kinetic characteristics of the limb during side-hopping and hip/knee interaction during this motion have not been clarified. The purposes of this study were to examine the biomechanical parameters of the knee during side hop and analyze its relationship with clinical measurements of hip function. [Subjects and Methods] Eleven male college rugby players were included. A three-dimensional motion analysis system was used to assess motion characteristics of the knee during side hop. In addition, hip range of motion and muscle strength were evaluated. Subsequently, the relationship between knee motion and the clinical parameters of the hip was analyzed. [Results] In the lateral touchdown phase, the knee was positioned in an abducted and externally rotated position, and increasing abduction moment was applied to the knee. An analysis of the interaction between knee motion and hip function showed that range of motion for hip internal rotation was significantly correlated with external rotation angle and external rotation/abduction moments of the knee during the lateral touchdown phase. [Conclusion] Range of motion for hip internal rotation should be taken into consideration for identifying the biomechanical characteristics in the side hop test results. PMID:27799670

  2. Preschoolers' Mental Rotation: Sex Differences in Hemispheric Asymmetry

    ERIC Educational Resources Information Center

    Hahn, Nicola; Jansen, Petra; Heil, Martin

    2010-01-01

    Mental rotation performance has been found to produce one of the largest sex differences in cognition accompanied by sex differences in functional cerebral asymmetry. Although sex differences in mental rotation performance can be reliably demonstrated as early as age 5 years old, that is, long before puberty, no data exist as to whether…

  3. Perception of the upright and susceptibility to motion sickness as functions of angle of tilt and angular velocity in off-vertical rotation. [human tolerance to angular accelerations

    NASA Technical Reports Server (NTRS)

    Miller, E. F., II; Graybiel, A.

    1973-01-01

    Motion sickness susceptibility of four normal subjects was measured in terms of duration of exposure necessary to evoke moderate malaise (MIIA) as a function of velocity in a chair rotated about a central axis tilted 10 deg with respect to gravitational upright. The subjects had little or no susceptibility to this type of rotation at 2.5 and 5.0 rpm, but with further increases in rate, the MIIA endpoint was always reached and with ever shorter test durations. Minimal provocative periods for all subjects were found at 15 or 20 rpm. Higher rotational rates dramatically reversed the vestibular stressor effect, and the subjects as a group tended to reach a plateau of relatively low susceptibility at 40 and 45 rpm. At these higher velocities, furthermore, the subjects essentially lost their sensation of being tilted off vertical. In the second half of the study, the effect of tilt angle was varied while the rotation rate was maintained at a constant 17.5 rpm. Two subjects were completely resistant to symptoms of motion sickness when rotated at 2.5 deg off vertical; with greater off-vertical angles, the susceptibility of all subjects increased sharply at first, then tapered off in a manner reflecting a Fechnerian function.

  4. Rotational viscometer for high-pressure, high-temperature fluids

    DOEpatents

    Carr, K.R.

    1983-06-06

    The invention is a novel rotational viscometer which is well adapted for use with fluids at high temperatures and/or pressures. In one embodiment, the viscometer include a substantially non-magnetic tube having a closed end and having an open end in communication with a fluid whose viscosity is to be determined. An annular drive magnet is mounted for rotation about the tube. The tube encompasses and supports a rotatable shaft assembly which carries a rotor, or bob, for insertion in the fluid. Affixed to the shaft are (a) a second magnet which is magnetically coupled to the drive magnet and (b) a third magnet. In a typical operation, the drive magnet is rotated to turn the shaft assembly while the shaft rotor is immersed in the fluid. The viscous drag on the rotor causes the shaft assembly to lag the rotation of the drive magnet by an amount which is a function of the amount of viscous drag. A first magnetic pickup generates a waveform whose phase is a function of the angular position of the drive magnet. A second magnetic pickup generates a waveform whose phase is a function of the angular position of the third magnet. Means are provided to generate an output indicative of the phase difference between the two waveforms. The viscometer is comparatively simple, inexpensive, rugged, and does not require shaft seals.

  5. Slowly rotating homogeneous masses revisited

    NASA Astrophysics Data System (ADS)

    Reina, Borja

    2016-02-01

    Hartle's model for slowly rotating stars has been extensively used to compute equilibrium configurations of slowly rotating stars to second order in perturbation theory in general relativity, given a barotropic equation of state. A recent study based on the modern theory of perturbed matchings concludes that the functions in the (first and second order) perturbation tensors can always be taken as continuous at the surface of the star, except for the second-order function m0. This function presents a jump at the surface of the star proportional to the discontinuity of the energy density there. This concerns only a particular outcome of the model: the change in mass δM. In this paper, the amended change in mass is calculated for the case of constant density stars.

  6. Quality of life measures in glioma patients with different grades: A preliminary study.

    PubMed

    Mahalakshmi, P; Vanisree, A J

    2015-01-01

    Plethora of information exists in the literature on pathology of the glioma while prevailing research data on quality-of-life (QOL) of glioma patients marks dearth thus demanding more studies. In this study, we examined the QOL of different grades of glioma patients among the Chennai population in India. A total of 162 patients with different grades of glioma enrolled from August 2007 to February 2011, at their first contact to Department of Neurology and Neurosurgery, Government General Hospital, Chennai, India were included and their QOL was assessed by European Organization for Research and Treatment of Cancer Core QOL questionnaire (EORTC QLQc-30), EORTC brain cancer module (QLQ BN-20). Both low and high grade glioma (LGG and HGG) patients had poor mean scores in social functioning (87.0), physical functioning (82.0) and emotional functioning (75.2) and role functioning (58.9). The mean scores on cognitive functioning (61.9) and global QOL (60.3) were better. Age, Karnofsky performance status, World Health Organization grades showed significant associations with all functional scales. The percentage values were higher for symptoms of fatigue (76.9%), pain (71.5%), financial difficulties (77.6%) and appetite loss (38.46%) in both LGG and HGG. Similarly, with respect to QLQ-BN20 domains, HGG patients showed more symptoms than low grade with a significant correlation in communication deficit problems (P = 0.02), headache (P = 0.04), seizures (P < 0.01), hair loss (P < 0.05) than the other symptoms. This initial assessment suggests that an increasing burden of symptoms exists, with poor QOL and survival, which has become a major concern in different grades of glioma patients.

  7. Principles and biophysical applications of single particle super-localization and rotational tracking

    NASA Astrophysics Data System (ADS)

    Gu, Yan

    While conventional Single Particle Tracking (SPT) techniques acquire 2D or 3D trajectories of particle probes, we have developed Single Particle Orientation and Rotational Tracking (SPORT) techniques to extract orientation and rotational information. Combined with DIC microscopy, the SPORT technique has been applied in biophysical studies, including membrane diffusion and intracellular transport. The rotational dynamics of nanoparticle vectors on live cell membranes was recorded and its influence on the fate of these nanoparticle vectors was elucidated. The rotational motions of gold nanorods with various surface modifiers were tracked continuously at a temporal resolution of 5 ms under a DIC microscope. We found that the rotational behaviors of gold nanorod vectors are strongly related to their surface charge, specific surface functional groups, and the availability of receptors on cell membranes. The study of rotational Brownian motion of nanoparticles on cell membranes will lead to a better understanding of the mechanisms of drug delivery and provide guidance in designing surface modification strategies for drug delivery vectors under various circumstances. To characterize the rotation mode of surface functionalized gold nanorods on cell membranes, the SPORT technique is combined with the correlation analysis of the bright and dark DIC intensities. The unique capabilities of visualizing and understanding rotational motions of functionalized nanoparticles on live cell membranes allow us to correlate rotational and translational dynamics in unprecedented detail and provide new insights for complex membrane processes, including electrostatic interactions, ligand-receptor binding, and lateral (confined and hopping) diffusion of membrane receptors. Surface-functionalized nanoparticles interact with the membrane in fundamentally different ways and exhibit distinct rotational modes. The early events of particle-membrane approach and attachment are directly visualized for the first time. The rotational dynamics of cargos in both active directional transport and pausing stages of axonal transport was also visualized using high-speed SPORT with a temporal resolution of 2 ms. Both long and short pauses are imaged, and the correlations between the pause duration, the rotational behaviour of the cargo at the pause, and the moving direction after the pause are established. Furthermore, the rotational dynamics leading to switching tracks are visualized in detail. These first-time observations of cargo's rotational dynamics provide new insights on how kinesin and dynein motors take the cargo through the alternating stages of active directional transport and pause. To improve the localization precision of the SPT technique with DIC microscopy, a precise three-dimensional (3D) localization method of spherical gold nanoparticle probes using model-based correlation coefficient mapping was introduced. To accomplish this, a stack of sample images at different z-positions are acquired, and a 3D intensity profile of the probe serving as the model is used to map out the positions of nanoparticles in the sample. By using this model-based correlation imaging method, precise localization can be achieved in imaging techniques with complicated point spread functions (PSF) such as differential interference contrast (DIC) microscopy. The 3D superlocalization method was applied to tracking gold nanospheres during live endocytosis events. Finally, a novel dual-modality imaging technique has been developed to super-localize a single gold nanorod while providing its orientation and rotational information. The super-localization of the gold nanorod can be accomplished by curve fitting the modified bright-field images generated by one of the two beams laterally shifted by the first Nomarski prism in a DIC microscope. The orientation and rotational information is derived from the DIC images of gold nanorods. The new imaging setup has been applied to study the steric hindrance induced by relatively large cargos in the microtubule gliding assay and to track nanocargos in the crowded cellular environment.

  8. Principles and biophysical applications of single particle super-localization and rotational tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gu, Yan

    While conventional Single Particle Tracking (SPT) techniques acquire 2D or 3D trajectories of particle probes, we have developed Single Particle Orientation and Rotational Tracking (SPORT) techniques to extract orientation and rotational information. Combined with DIC microscopy, the SPORT technique has been applied in biophysical studies, including membrane diffusion and intracellular transport. The rotational dynamics of nanoparticle vectors on live cell membranes was recorded and its influence on the fate of these nanoparticle vectors was elucidated. The rotational motions of gold nanorods with various surface modifiers were tracked continuously at a temporal resolution of 5 ms under a DIC microscope. Wemore » found that the rotational behaviors of gold nanorod vectors are strongly related to their surface charge, specific surface functional groups, and the availability of receptors on cell membranes. The study of rotational Brownian motion of nanoparticles on cell membranes will lead to a better understanding of the mechanisms of drug delivery and provide guidance in designing surface modification strategies for drug delivery vectors under various circumstances. To characterize the rotation mode of surface functionalized gold nanorods on cell membranes, the SPORT technique is combined with the correlation analysis of the bright and dark DIC intensities. The unique capabilities of visualizing and understanding rotational motions of functionalized nanoparticles on live cell membranes allow us to correlate rotational and translational dynamics in unprecedented detail and provide new insights for complex membrane processes, including electrostatic interactions, ligand-receptor binding, and lateral (confined and hopping) diffusion of membrane receptors. Surface-functionalized nanoparticles interact with the membrane in fundamentally different ways and exhibit distinct rotational modes. The early events of particle-membrane approach and attachment are directly visualized for the first time. The rotational dynamics of cargos in both active directional transport and pausing stages of axonal transport was also visualized using high-speed SPORT with a temporal resolution of 2 ms. Both long and short pauses are imaged, and the correlations between the pause duration, the rotational behaviour of the cargo at the pause, and the moving direction after the pause are established. Furthermore, the rotational dynamics leading to switching tracks are visualized in detail. These first-time observations of cargo's rotational dynamics provide new insights on how kinesin and dynein motors take the cargo through the alternating stages of active directional transport and pause. To improve the localization precision of the SPT technique with DIC microscopy, a precise three-dimensional (3D) localization method of spherical gold nanoparticle probes using model-based correlation coefficient mapping was introduced. To accomplish this, a stack of sample images at different z-positions are acquired, and a 3D intensity profile of the probe serving as the model is used to map out the positions of nanoparticles in the sample. By using this model-based correlation imaging method, precise localization can be achieved in imaging techniques with complicated point spread functions (PSF) such as differential interference contrast (DIC) microscopy. The 3D superlocalization method was applied to tracking gold nanospheres during live endocytosis events. Finally, a novel dual-modality imaging technique has been developed to super-localize a single gold nanorod while providing its orientation and rotational information. The super-localization of the gold nanorod can be accomplished by curve fitting the modified bright-field images generated by one of the two beams laterally shifted by the first Nomarski prism in a DIC microscope. The orientation and rotational information is derived from the DIC images of gold nanorods. The new imaging setup has been applied to study the steric hindrance induced by relatively large cargos in the microtubule gliding assay and to track nanocargos in the crowded cellular environment.« less

  9. Sex differences in mental rotation with polygons of different complexity: Do men utilize holistic processes whereas women prefer piecemeal ones?

    PubMed

    Heil, Martin; Jansen-Osmann, Petra

    2008-05-01

    Sex differences in mental rotation were investigated as a function of stimulus complexity with a sample size of N = 72. Replicating earlier findings with polygons, mental rotation was faster for males than for females, and reaction time increased with more complex polygons. Additionally, sex differences increased for complex polygons. Most importantly, however, mental rotation speed decreased with increasing complexity for women but did not change for men. Thus, the sex effects reflect a difference in strategy, with women mentally rotating the polygons in an analytic, piecemeal fashion and men using a holistic mode of mental rotation.

  10. Rotation of a Moonless Earth

    NASA Technical Reports Server (NTRS)

    Lissauer, Jack J.; Barnes, Jason W.; Chambers, John E.

    2013-01-01

    We numerically explore the obliquity (axial tilt) variations of a hypothetical moonless Earth. Previous work has shown that the Earth's Moon stabilizes Earth's obliquity such that it remains within a narrow range, between 22.1 deg and 24.5 deg. Without lunar influence, a frequency-map analysis by Laskar et al. showed that the obliquity could vary between 0 deg. and 85 deg. This has left an impression in the astrobiology community that a large moon is necessary to maintain a habitable climate on an Earth-like planet. Using a modified version of the orbital integrator mercury, we calculate the obliquity evolution for moonless Earths with various initial conditions for up to 4 Gyr. We find that while obliquity varies significantly more than that of the actual Earth over 100,000 year timescales, the obliquity remains within a constrained range, typically 20-25 deg. in extent, for timescales of hundreds of millions of years. None of our Solar System integrations in which planetary orbits behave in a typical manner show obliquity accessing more than 65% of the full range allowed by frequency-map analysis. The obliquities of moonless Earths that rotate in the retrograde direction are more stable than those of pro-grade rotators. The total obliquity range explored for moonless Earths with rotation periods shorter than 12 h is much less than that for slower-rotating moonless Earths. A large moon thus does not seem to be needed to stabilize the obliquity of an Earth-like planet on timescales relevant to the development of advanced life.

  11. MODELING FUNCTIONALLY GRADED INTERPHASE REGIONS IN CARBON NANOTUBE REINFORCED COMPOSITES

    NASA Technical Reports Server (NTRS)

    Seidel, G. D.; Lagoudas, D. C.; Frankland, S. J. V.; Gates, T. S.

    2006-01-01

    A combination of micromechanics methods and molecular dynamics simulations are used to obtain the effective properties of the carbon nanotube reinforced composites with functionally graded interphase regions. The multilayer composite cylinders method accounts for the effects of non-perfect load transfer in carbon nanotube reinforced polymer matrix composites using a piecewise functionally graded interphase. The functional form of the properties in the interphase region, as well as the interphase thickness, is derived from molecular dynamics simulations of carbon nanotubes in a polymer matrix. Results indicate that the functional form of the interphase can have a significant effect on all the effective elastic constants except for the effective axial modulus for which no noticeable effects are evident.

  12. Reconstructive operations for the upper limb after brachial plexus palsy.

    PubMed

    Rühmann, Oliver; Schmolke, Stephan; Bohnsack, Michael; Carls, Jörg; Flamme, Christian; Wirth, Carl Joachim

    2004-07-01

    Limited function due to paralysis following brachial plexus lesions can be improved by secondary operations of the bony and soft tissue. Between April 1994 and December 2000, 109 patients suffering from arm-plexus lesions underwent a total of 144 reconstructive operations guided by our concept of integrated therapy. The average age at the time of surgery was 32 years (range: 15-59). The following operations were performed: shoulder arthrodesis (23), trapezius transfer (74), rotation osteotomy of humerus (9), triceps to biceps transposition (9), transposition of forearm flexors or extensors (8), latissimus transfer (7), pectoralis transfer (1), teres major transfer (1), transposition of flexor carpi ulnaris to the tendons of extensor digitorum (10), and wrist arthrodesis (2). Prospectively, in all patients, the grade of muscle power of the affected upper extremity was evaluated prior to surgery. The follow-up period for all 144 operations was, on average, 22 months (range: 6-74). By means of operative measures, almost all patients obtained an improvement of shoulder function (100%) and stability (>90%), elbow flexion (85%), and hand, finger, and thumb (100%). When muscles malfunction after brachial plexus lesions, one should take into account the individual neuromuscular defect, passive joint function, and bony deformities; different procedures such as muscle transpositions, arthrodeses, and corrective osteotomies can then be performed to improve function of the upper extremity. Each form of operative treatment presents patients with certain benefits and all are integrated into a total treatment plan for the affected extremity.

  13. Functional outcome after the Hoffer procedure.

    PubMed

    Murabit, Amera; Gnarra, Maria; O'Grady, Kathleen; Morhart, Michael; Olson, Jaret L

    2013-06-01

    Children with obstetrical brachial plexus injury often develop an internal rotation and adduction contracture about the shoulder as a secondary deformity, resulting in an inability to externally rotate and abduct the shoulder. The Hoffer procedure is evaluated for its potential benefit in improving shoulder abduction and external rotation and its impact on activities of daily living. This is a retrospective review of patients treated in brachial plexus injury clinic who underwent tendon transfer procedures about the shoulder. Preoperative and postoperative active movement and active range of motion were measured and recorded using the Mallet scale and the Active Movement Scale. Twenty patients were included in the study. Average age at time of surgery was 6.35 years. Thirteen patients had primary brachial plexus reconstructive surgery and four patients had concomitant wrist extension tendon transfer procedures. All patients had full passive range of motion preoperatively. The average follow-up period was 25.45 months. Average differences in pre-Hoffer and post-Hoffer Mallet scale scores are as follows: active abduction, 1.20; external rotation, 1.35; hand-to-neck, 1.25; hand-to-back, 0.75; hand-to-mouth, 0.65; and aggregate score, 5.20 (p<0.001 for all). Average differences in relevant pre-Hoffer and post-Hoffer Active Movement Scale scores are as follows: shoulder abduction, 2.10; shoulder external rotation, 4.25; and shoulder internal rotation, -0.80. All patients maintained full range of motion passively; thus, no functional loss was experienced. These results showed very high statistical significance (p<0.001 for all) and clinical significance. Younger patients (≤6 years) and those with better preoperative shoulder flexion and shoulder internal rotation yielded better postoperative results. The Hoffer procedure provides clinically and statistically significant improvement in external rotation and abduction while preserving functional internal rotation range in the child with obstetrical brachial plexus palsy and secondary shoulder deformity. Therapeutic, IV.

  14. Electro-mechanical sine/cosine generator

    NASA Technical Reports Server (NTRS)

    Flagge, B. (Inventor)

    1972-01-01

    An electromechanical device for generating both sine and cosine functions is described. A motor rotates a cylinder about an axis parallel to and a slight distance from the central axis of the cylinder. Two noncontacting displacement sensing devices are placed ninety degrees apart, equal distances from the axis of rotation of the cylinder and short distances above the surface of cylinder. Each of these sensing devices produces an electrical signal proportional to the distance that it is away from the cylinder. Consequently, as the cylinder is rotated the outputs from the two sensing devices are the sine and cosine functions.

  15. Thermomechanical Fractional Model of TEMHD Rotational Flow

    PubMed Central

    Hamza, F.; Abd El-Latief, A.; Khatan, W.

    2017-01-01

    In this work, the fractional mathematical model of an unsteady rotational flow of Xanthan gum (XG) between two cylinders in the presence of a transverse magnetic field has been studied. This model consists of two fractional parameters α and β representing thermomechanical effects. The Laplace transform is used to obtain the numerical solutions. The fractional parameter influence has been discussed graphically for the functions field distribution (temperature, velocity, stress and electric current distributions). The relationship between the rotation of both cylinders and the fractional parameters has been discussed on the functions field distribution for small and large values of time. PMID:28045941

  16. Photoelectric angle converter

    NASA Astrophysics Data System (ADS)

    Podzharenko, Volodymyr A.; Kulakov, Pavlo I.

    2001-06-01

    The photo-electric angle transmitter of rotation is offered, at which the output voltage is linear function of entering magnitude. In a transmitter the linear phototransducer is used on the basis of pair photo diode -- operating amplifier, which output voltage is linear function of the area of an illuminated photosensitive stratum, and modulator of a light stream of the special shape, which ensures a linear dependence of this area from an angle of rotation. The transmitter has good frequent properties and can be used for dynamic measurements of an angular velocity and angle of rotation, in systems of exact drives and systems of autocontrol.

  17. An improved OpenSim gait model with multiple degrees of freedom knee joint and knee ligaments.

    PubMed

    Xu, Hang; Bloswick, Donald; Merryweather, Andrew

    2015-08-01

    Musculoskeletal models are widely used to investigate joint kinematics and predict muscle force during gait. However, the knee is usually simplified as a one degree of freedom joint and knee ligaments are neglected. The aim of this study was to develop an OpenSim gait model with enhanced knee structures. The knee joint in this study included three rotations and three translations. The three knee rotations and mediolateral translation were independent, with proximodistal and anteroposterior translations occurring as a function of knee flexion/extension. Ten elastic elements described the geometrical and mechanical properties of the anterior and posterior cruciate ligaments (ACL and PCL), and the medial and lateral collateral ligaments (MCL and LCL). The three independent knee rotations were evaluated using OpenSim to observe ligament function. The results showed that the anterior and posterior bundles of ACL and PCL (aACL, pACL and aPCL, pPCL) intersected during knee flexion. The aACL and pACL mainly provided force during knee flexion and adduction, respectively. The aPCL was slack throughout the range of three knee rotations; however, the pPCL was utilised for knee abduction and internal rotation. The LCL was employed for knee adduction and rotation, but was slack beyond 20° of knee flexion. The MCL bundles were mainly used during knee adduction and external rotation. All these results suggest that the functions of knee ligaments in this model approximated the behaviour of the physical knee and the enhanced knee structures can improve the ability to investigate knee joint biomechanics during various gait activities.

  18. Passive scalars: Mixing, diffusion, and intermittency in helical and nonhelical rotating turbulence

    NASA Astrophysics Data System (ADS)

    Imazio, P. Rodriguez; Mininni, P. D.

    2017-03-01

    We use direct numerical simulations to compute structure functions, scaling exponents, probability density functions, and effective transport coefficients of passive scalars in turbulent rotating helical and nonhelical flows. We show that helicity affects the inertial range scaling of the velocity and of the passive scalar when rotation is present, with a spectral law consistent with ˜k⊥-1.4 for the passive scalar variance spectrum. This scaling law is consistent with a phenomenological argument [P. Rodriguez Imazio and P. D. Mininni, Phys. Rev. E 83, 066309 (2011), 10.1103/PhysRevE.83.066309] for rotating nonhelical flows, which follows directly from Kolmogorov-Obukhov scaling and states that if energy follows a E (k ) ˜k-n law, then the passive scalar variance follows a law V (k ) ˜k-nθ with nθ=(5 -n ) /2 . With the second-order scaling exponent obtained from this law, and using the Kraichnan model, we obtain anomalous scaling exponents for the passive scalar that are in good agreement with the numerical results. Multifractal intermittency models are also considered. Intermittency of the passive scalar is stronger than in the nonhelical rotating case, a result that is also confirmed by stronger non-Gaussian tails in the probability density functions of field increments. Finally, Fick's law is used to compute the effective diffusion coefficients in the directions parallel and perpendicular to rotation. Calculations indicate that horizontal diffusion decreases in the presence of helicity in rotating flows, while vertical diffusion increases. A simple mean field argument explains this behavior in terms of the amplitude of velocity fluctuations.

  19. Social and Academic Expectations about High School for At-Risk Rural Youth

    ERIC Educational Resources Information Center

    Stein, Gabriela Livas; Hussong, Andrea

    2007-01-01

    This study examines high school expectancies in a sample of at-risk, rural youth, and how these expectancies relate to 8th grade functioning, 9th grade functioning, and 9th grade experiences of high school. A total of 76 eighth-graders and their parents, drawn from a larger study of the transition to high school, participated in interviews the…

  20. Reverse shoulder arthroplasty for massive rotator cuff tear: risk factors for poor functional improvement.

    PubMed

    Hartzler, Robert U; Steen, Brandon M; Hussey, Michael M; Cusick, Michael C; Cottrell, Benjamin J; Clark, Rachel E; Frankle, Mark A

    2015-11-01

    Some patients unexpectedly have poor functional improvement after reverse shoulder arthroplasty (RSA) for massive rotator cuff tear without glenohumeral arthritis. Our aim was to identify risk factors for this outcome. We also assessed the value of RSA for cases with poor functional improvement vs. The study was a retrospective case-control analysis for primary RSA performed for massive rotator cuff tear without glenohumeral arthritis with minimum 2-year follow-up. Cases were defined as Simple Shoulder Test (SST) score improvement of ≤1, whereas controls improved SST score ≥2. Risk factors were chosen on the basis of previous association with poor outcomes after shoulder arthroplasty. Latissimus dorsi tendon transfer results were analyzed as a subgroup. Value was defined as improvement in American Shoulder and Elbow Surgeons (ASES) score per $10,000 hospital cost. In a multivariate binomial logistic regression analysis, neurologic dysfunction (P = .006), age <60 years (P = .02), and high preoperative SST score (P = .03) were independently associated with poor functional improvement. Latissimus dorsi tendon transfer patients significantly improved in active external rotation (-0.3° to 38.7°; P < .01). The value of RSA (ΔASES/$10,000 cost) for cases was 0.8 compared with 17.5 for controls (P < .0001). Young age, high preoperative function, and neurologic dysfunction were associated with poor functional improvement. Surgeons should consider these associations in counseling and selection of patients. Concurrent latissimus dorsi transfer was successful in restoring active external rotation in a subgroup of patients. The critical economic importance of improved patient selection is emphasized by the very low value of the procedure in the case group. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Effects of Asymptomatic Rotator Cuff Pathology On In-Vivo Shoulder Motion and Clinical Outcomes

    PubMed Central

    Baumer, Timothy G.; Dischler, Jack; Mende, Veronica; Zauel, Roger; van Holsbeeck, Marnix; Siegal, Daniel S.; Divine, George; Moutzouros, Vasilios; Bey, Michael J.

    2017-01-01

    Background The incidence of asymptomatic rotator cuff tears has been reported to range from 15–39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. The objective of this study was to assess the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. Methods 46 asymptomatic volunteers (age: 60.3±7.5) with normal shoulder function underwent a clinical ultrasound exam to document the condition of their rotator cuff. The ultrasound imaging identified subjects as healthy (n=14) or pathologic (n=32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex, and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and VAS pain scores. Results Compared to healthy subjects, the subjects with rotator cuff pathology had significantly less abduction (p=0.050) and elevation (p=0.041) strength, their humerus was positioned more inferiorly on the glenoid (p=0.018), and the glenohumeral contact path length was longer (p=0.007). No significant differences were detected in terms of WORC, VAS, ROM, or acromiohumeral distance. Discussion The differences observed between the healthy subjects and subjects with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology. Level of evidence Basic Science Study, Kinesiology PMID:28131679

  2. In Vivo Talocrural Joint Contact Mechanics With Functional Ankle Instability.

    PubMed

    Kobayashi, Takumi; Suzuki, Eiichi; Yamazaki, Naohito; Suzukawa, Makoto; Akaike, Atsushi; Shimizu, Kuniaki; Gamada, Kazuyoshi

    2015-12-01

    Functional ankle instability (FAI) may involve abnormal kinematics and contact mechanics during ankle internal rotation. Understanding of these abnormalities is important to prevent secondary problems in patients with FAI. However, there are no in vivo studies that have investigated talocrural joint contact mechanics during weightbearing ankle internal rotation. The objective of this study to determine talocrural contact mechanics during weightbearing ankle internal rotation in patients with FAI. Twelve male subjects with unilateral FAI (age range, 18-26 years) were enrolled. Computed tomography and fluoroscopic imaging of both lower extremities were obtained during weightbearing passive ankle joint complex rotation. Three-dimensional bone models created from the computed tomographic images were matched to the fluoroscopic images to compute 6 degrees of freedom for talocrural joint kinematics. The closest contact area in the talocrural joint in ankle neutral rotation and maximum internal rotation during either dorsiflexion or plantar flexion was determined using geometric bone models and talocrural joint kinematics data. The closest contact area in the talus shifted anteromedially during ankle dorsiflexion-internal rotation, whereas it shifted posteromedially during ankle plantar flexion-internal rotation. The closest contact area in FAI joints was significantly more medial than that in healthy joints during maximum ankle internal rotation and was associated with excessive talocrural internal rotation or inversion. This study demonstrated abnormal talocrural kinematics and contact mechanics in FAI subjects. Such abnormal kinematics may contribute to abnormal contact mechanics and may increase cartilage stress in FAI joints. Therapeutic, Level IV: cross-sectional case-control study. © 2015 The Author(s).

  3. Nutritional and functional characteristics of seven grades of black tea produced in Turkey.

    PubMed

    Serpen, Arda; Pelvan, Ebru; Alasalvar, Cesarettin; Mogol, Burçe Ataç; Yavuz, Havvana Tuba; Gökmen, Vural; Özcan, Nihat; Özçelik, Beraat

    2012-08-08

    Seven grades of black tea [high-quality black tea (grades 1-3) and low-quality black tea (grades 4-7)], processed by ÇAYKUR Tea Processing Plant (Rize, Turkey), were examined for their proximate composition, dietary fiber, minerals, and water-soluble vitamins as well as total phenolic content, various antioxidant assays, phenolics (flavanols, alkoloids, condensed phenolics, and phenolic acids), chlorophylls, and carotenoids. Some variations, albeit to different extents, were observed (p < 0.05) among these parameters in seven grades of black tea. With respect to proximate composition, dietary fiber was the predominant compound (ranging from 49.68 to 54.31 g/100 g), followed by protein, carbohydrate, and, to a lesser extent, ash, moisture, and fat. Thirteen minerals, four water-soluble vitamins, six flavanols, two alkoloids, three condensed phenolics, one phenolic acid, two chlorophylls, and two carotenoids were identified in the seven grades of black tea. Total phenol content ranged from 7.52 to 8.29 g of gallic acid equivalents (GAE)/100 g, being lowest in grade 6 and highest in grade 1. With regard to antioxidant activities, a large variation in oxygen radical absorbance capacity (ORAC) values was observed among all grades of black tea (ranging from 777 μmol of trolox equivalents (TE)/g in grade 7 to 1210 μmol of TE/g in grade 3). The present work suggests that high- and low-quality black teas should not be distinguished on the basis of their nutritional and functional characteristics. The combination of nutritional compounds together with functional characteristics renders combination effects that provide the characteristic quality of each grade of black tea.

  4. Effects of asymptomatic rotator cuff pathology on in vivo shoulder motion and clinical outcomes.

    PubMed

    Baumer, Timothy G; Dischler, Jack; Mende, Veronica; Zauel, Roger; van Holsbeeck, Marnix; Siegal, Daniel S; Divine, George; Moutzouros, Vasilios; Bey, Michael J

    2017-06-01

    The incidence of asymptomatic rotator cuff tears has been reported to range from 15% to 39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. This study assessed the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. A clinical ultrasound examination was performed in 46 asymptomatic volunteers (age: 60.3 ± 7.5 years) with normal shoulder function to document the condition of their rotator cuff. The ultrasound imaging identified the participants as healthy (n = 14) or pathologic (n = 32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex (Biodex Medical Systems, Inc., Shirley, NY, USA), and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale pain scores. Compared with healthy volunteers, those with rotator cuff pathology had significantly less abduction (P = .050) and elevation (P = .041) strength, their humerus was positioned more inferiorly on the glenoid (P = .018), and the glenohumeral contact path length was longer (P = .007). No significant differences were detected in the Western Ontario Rotator Cuff Index, visual analog scale, range of motion, or acromiohumeral distance. The differences observed between the healthy volunteers and those with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. Asymmetric pelvic and hip rotation in children with bilateral cerebral palsy: uni- or bilateral femoral derotation osteotomy?

    PubMed

    Niklasch, M; Döderlein, L; Klotz, M C; Braatz, F; Wolf, S I; Dreher, T

    2015-02-01

    Internal rotation gait is common among children with bilateral cerebral palsy. However, despite bilaterally increased femoral anteversion asymmetric internal rotation gait is often found. Femoral derotation osteotomy (FDO) is commonly performed bilaterally. Variable functional outcomes are reported especially in cases with mild internal hip rotation during gait and abnormal preoperative pelvic rotation. A major question is if a unilateral treatment of the more involved side in asymmetric cases leads to a comparable or even superior outcome. One hundred and nine children with spastic bilateral CP treated with FDO with pre- and 1-year postoperative 3D gait analysis were retrospectively collected. The asymmetry was calculated from the preoperative difference between both limbs in hip rotation obtained by 3D gait analysis. Twenty-eight children with asymmetry larger than 20° were selected and classified into two groups, according to whether they obtained a unilateral or bilateral FDO. Preoperative clinical examination and pre- and postoperative hip and pelvic rotation in gait analysis on the more and the less involved side did not differ significantly between both groups. Interestingly, in both groups, hip rotation did not change significantly in less-involved limbs, although intraoperative derotation averaged 25°. After unilateral FDO a significant change in pelvic rotation resulted, whereas this was not found after bilateral FDO. The results of this study suggest that unilateral FDO in children with asymmetric internal rotation gait leads to a comparable functional outcome compared to bilateral treatment. Furthermore, it was shown for the first time that considering the asymmetry has a positive effect on pelvic rotation. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. A new framing approach in guideline development to manage different sources of knowledge.

    PubMed

    Lukersmith, Sue; Hopman, Katherine; Vine, Kristina; Krahe, Lee; McColl, Alexander

    2017-02-01

    Contemporary guideline methodology struggles to consider context and information from different sources of knowledge besides quantitative research. Return to work programmes involve multiple components and stakeholders. If the guideline is to be relevant and practical for a complex intervention such as return to work, it is essential to use broad sources of knowledge. This paper reports on a new method in guideline development to manage different sources of knowledge. The method used framing for the return-to-work guidance within the Clinical Practice Guidelines for the Management of Rotator Cuff Syndrome in the Workplace. The development involved was a multi-disciplinary working party of experts including consumers. The researchers considered a broad range of research, expert (practice and experience) knowledge, the individual's and workplace contexts, and used framing with the International Classification of Functioning, Disability and Health. Following a systematic database search on four clinical questions, there were seven stages of knowledge management to extract, unpack, map and pack information to the ICF domains framework. Companion graded recommendations were developed. The results include practical examples, user and consumer guides, flow charts and six graded or consensus recommendations on best practice for return to work intervention. Our findings suggest using framing in guideline methodology with internationally accepted frames such as the ICF is a reliable and transparent framework to manage different sources of knowledge. Future research might examine other examples and methods for managing complexity and using different sources of knowledge in guideline development. © 2016 John Wiley & Sons, Ltd.

  7. Reactive scattering with row-orthonormal hyperspherical coordinates. 4. Four-dimensional-space Wigner rotation function for pentaatomic systems.

    PubMed

    Kuppermann, Aron

    2011-05-14

    The row-orthonormal hyperspherical coordinate (ROHC) approach to calculating state-to-state reaction cross sections and bound state levels of N-atom systems requires the use of angular momentum tensors and Wigner rotation functions in a space of dimension N - 1. The properties of those tensors and functions are discussed for arbitrary N and determined for N = 5 in terms of the 6 Euler angles involved in 4-dimensional space.

  8. The Ottawa panel clinical practice guidelines for the management of knee osteoarthritis. Part three: aerobic exercise programs.

    PubMed

    Brosseau, Lucie; Taki, Jade; Desjardins, Brigit; Thevenot, Odette; Fransen, Marlene; Wells, George A; Mizusaki Imoto, Aline; Toupin-April, Karine; Westby, Marie; Álvarez Gallardo, Inmaculada C; Gifford, Wendy; Laferrière, Lucie; Rahman, Prinon; Loew, Laurianne; De Angelis, Gino; Cavallo, Sabrina; Shallwani, Shirin Mehdi; Aburub, Ala'; Bennell, Kim L; Van der Esch, Martin; Simic, Milena; McConnell, Sara; Harmer, Alison; Kenny, Glen P; Paterson, Gail; Regnaux, Jean-Philippe; Lefevre-Colau, Marie-Martine; McLean, Linda

    2017-05-01

    To identify effective aerobic exercise programs and provide clinicians and patients with updated, high-quality recommendations concerning traditional land-based exercises for knee osteoarthritis. A systematic search and adapted selection criteria included comparative controlled trials with strengthening exercise programs for patients with knee osteoarthritis. A panel of experts reached consensus on the recommendations using a Delphi survey. A hierarchical alphabetical grading system (A, B, C+, C, D, D+, or D-) was used, based on statistical significance ( P < 0.5) and clinical importance (⩾15% improvement). The five high-quality studies included demonstrated that various aerobic training exercises are generally effective for improving knee osteoarthritis within a 12-week period. An aerobic exercise program demonstrated significant improvement for pain relief (Grade B), physical function (Grade B) and quality of life (Grade C+). Aerobic exercise in combination with strengthening exercises showed significant improvement for pain relief (3 Grade A) and physical function (2 Grade A, 2 Grade B). A short-term aerobic exercise program with/without muscle strengthening exercises is promising for reducing pain, improving physical function and quality of life for individuals with knee osteoarthritis.

  9. Computer program to simulate Raman scattering

    NASA Technical Reports Server (NTRS)

    Zilles, B.; Carter, R.

    1977-01-01

    A computer program is described for simulating the vibration-rotation and pure rotational spectrum of a combustion system consisting of various diatomic molecules and CO2 as a function of temperature and number density. Two kinds of spectra are generated: a pure rotational spectrum for any mixture of diatomic and linear triatomic molecules, and a vibrational spectrum for diatomic molecules. The program is designed to accept independent rotational and vibrational temperatures for each molecule, as well as number densities.

  10. Student attendance and academic performance in undergraduate obstetrics/gynecology clinical rotations.

    PubMed

    Deane, Richard P; Murphy, Deirdre J

    2013-12-04

    Student attendance is thought to be an important factor in the academic performance of medical students, in addition to having important regulatory, policy, and financial implications for medical educators. However, this relationship has not been well evaluated within clinical learning environments. To evaluate the relationship between student attendance and academic performance in a medical student obstetrics/gynecology clinical rotation. A prospective cohort study of student attendance at clinical and tutorial-based activities during a full academic year (September 2011 to June 2012) within a publicly funded university teaching hospital in Dublin, Ireland. Students were expected to attend 64 activities (26 clinical activities and 38 tutorial-based activities) but attendance was not mandatory. All 147 fourth-year medical students who completed an 8-week obstetrics/gynecology rotation were included. Student attendance at clinical and tutorial-based activities, recorded using a paper-based logbook. The overall examination score (out of a possible 200 points) was obtained using an 11-station objective structured clinical examination (40 points), an end-of-year written examination comprising 50 multiple-choice questions (40 points) and 6 short-answer questions (40 points), and an end-of-year long-case clinical/oral examination (80 points). Students were required to have an overall score of 100 points (50%) and a minimum of 40 points in the long-case clinical/oral examination (50%) to pass. The mean attendance rate was 89% (range, 39%-100% [SD, 11%], n = 57/64 activities). Male students (84% attendance, P = .001) and students who failed an end-of-year examination previously (84% attendance, P = .04) had significantly lower rates. There was a positive correlation between attendance and overall examination score (r = 0.59 [95% CI, 0.44-0.70]; P < .001). Both clinical attendance (r = 0.50 [95% CI, 0.32-0.64]; P < .001) and tutorial-based attendance (r = 0.57 [95% CI, 0.40-0.70]; P < .001) were positively correlated with overall examination score. The associations persisted after controlling for confounding factors of student sex, age, country of origin, previous failure in an end-of-year examination, and the timing of the rotation during the academic year. Distinction grades (overall score of ≥60%) were present only among students with attendance rates of 80% or higher. The odds of a distinction grade increased with each 10% increase in attendance (adjusted odds ratio, 5.52; 95% CI, 2.17-14.00). The majority of failure grades (6/10 students; 60%) occurred in students with attendance rates lower than 80%. The adjusted odds ratio for failure with attendance rates of 80% or higher was 0.11 (95% CI, 0.02-0.72). Among fourth-year medical students completing an 8-week obstetrics/gynecology clinical rotation, attendance at clinical and tutorial-based activities was positively correlated with overall examination scores. Further research is needed to understand whether the relationship is causal, and whether improving attendance rates can improve academic performance.

  11. Tissue Engineering for Rotator Cuff Repair: An Evidence-Based Systematic Review

    PubMed Central

    Maffulli, Nicola; Longo, Umile Giuseppe; Loppini, Mattia; Berton, Alessandra; Spiezia, Filippo; Denaro, Vincenzo

    2012-01-01

    The purpose of this systematic review was to address the treatment of rotator cuff tears by applying tissue engineering approaches to improve tendon healing, specifically platelet rich plasma (PRP) augmentation, stem cells, and scaffolds. Our systematic search was performed using the combination of the following terms: “rotator cuff”, “shoulder”, “PRP”, “platelet rich plasma”, “stemcells”, “scaffold”, “growth factors”, and “tissue engineering”. No level I or II studies were found on the use of scaffolds and stem cells for rotator cuff repair. Three studies compared rotator cuff repair with or without PRP augmentation. All authors performed arthroscopic rotator cuff repair with different techniques of suture anchor fixation and different PRP augmentation. The three studies found no difference in clinical rating scales and functional outcomes between PRP and control groups. Only one study showed clinical statistically significant difference between the two groups at the 3-month follow up. Any statistically significant difference in the rates of tendon rerupture between the control group and the PRP group was found using the magnetic resonance imaging. The current literature on tissue engineering application for rotator cuff repair is scanty. Comparative studies included in this review suggest that PRP augmented repair of a rotator cuff does not yield improved functional and clinical outcome compared with non-augmented repair at a medium and long-term followup. PMID:25098365

  12. Syndesmotic fixation in supination-external rotation ankle fractures: a prospective randomized study.

    PubMed

    Pakarinen, Harri J; Flinkkilä, Tapio E; Ohtonen, Pasi P; Hyvönen, Pekka H; Lakovaara, Martti T; Leppilahti, Juhana I; Ristiniemi, Jukka Y

    2011-12-01

    This study was designed to assess whether transfixion of an unstable syndesmosis is necessary in supination-external rotation (Lauge-Hansen SE/Weber B)-type ankle fractures. A prospective study of 140 patients with unilateral Lauge-Hansen supination-external rotation type 4 ankle fractures was done. After bony fixation, the 7.5-Nm standardized external rotation (ER) stress test for both ankles was performed under fluoroscopy. A positive stress examination was defined as a difference of more than 2 mm side-to-side in the tibiotalar or tibiofibular clear spaces on mortise radiographs. If the stress test was positive, the patient was randomized to either syndesmotic transfixion with 3.5-mm tricortical screws or no syndesmotic fixation. Clinical outcome was assessed using the Olerud-Molander scoring system, RAND 36-Item Health Survey, and Visual Analogue Scale (VAS) to measure pain and function after a minimum 1-year of followup. Twenty four (17%) of 140 patients had positive standardized 7.5-Nm ER stress tests after malleolar fixation. The stress view was positive three times on tibiotalar clear space, seven on tibiofibular clear space, and 14 times on both tibiotalar and tibiofibular clear spaces. There was no significant difference between the two randomization groups with regards to Olerud-Molander functional score, VAS scale measuring pain and function, or RAND 36-Item Health Survey pain or physical function at 1 year. Relevant syndesmotic injuries are rare in supination-external rotation ankle fractures, and syndesmotic transfixion with a screw did not influence the functional outcome or pain after the 1-year followup compared with no fixation.

  13. Teaching Mathematical Functions Using Geometric Functions Approach and Its Effect on Ninth Grade Students' Motivation

    ERIC Educational Resources Information Center

    Akçakin, Veysel

    2018-01-01

    The purpose of this study is to investigate the effects of using geometric functions approach on 9th grade students' motivation levels toward mathematics in functions unit. Participants of this study were 87 students who were ongoing in the first year of high school in Turkey. In this research, pretest and posttest control group quasiexperimental…

  14. Postoperative physical therapy program for latissimus dorsi and teres major tendons transfer to rotator cuff in children with obstetrical brachial plexus injury.

    PubMed

    Safoury, Yasser A; Eldesoky, Mohamed T; Abutaleb, Enas E; Atteya, Mohamed R; Gabr, Ahmed M

    2017-04-01

    The transfer of latissimus dorsi and teres major tendons to rotator cuff have been developed to rebalance the muscular dysfunction and improve shoulder range of motion in children with obstetrical brachial plexus palsy (OBPP). No previous study reported the ideal postoperative physical therapy program for these cases. The aim of the present study was to design appropriate postoperative physical therapy (PT) program after latissimus dorsi and teres major tendons transfer to rotator cuff in OBPP to improve upper limb function. Time series design. The patients were recruited from outpatient clinic of Kasr EL Aini Hospital, Cairo, Egypt. Forty seven OBPP infants (4.64±1.21 years with a range of 2.5 to 7 years, 21male and26 female) were allocated to one group. All patients had functional limitation in the involved arm due to muscle paralysis and contracture. Twenty-five patients had C5-C6 nerve root lesions while 22 had C5-C6-C7 nerve root lesions. The children underwent the surgical procedures of the transfer of latissimus dorsi and teres major tendons to rotator cuff. After the surgery the children participated in a designed physical therapy program for 6 months. Active shoulder abduction, flexion and external rotation range of motion (ROM) were assessed by electrogoniometer, and functional assessments were measured using the modified Mallet scale. All measurements were taken preoperative, 6 weeks, 3 months, and 6 months postoperatively after the application of the designed PT program. Repeated measure analysis of variance (ANOVA) followed by Bonferroni post-hoc test were used to show the improvement in all measured variables. Analysis revealed that shoulder abduction, flexion and external rotation ROM and shoulder function measured by modified Mallet scale were significantly improved (P<0.0001) after the designed postoperative PT program. It can be concluded that the combination treatment of surgical procedure and the postoperative physical therapy program seem to be effective in improving shoulder and arm functions in children with OBPP. This study describes a detailed physical therapy program after latissimus dorsi and teres major tendons transfer to rotator cuff in OBPP.

  15. Non-rigid Earth rotation series

    NASA Astrophysics Data System (ADS)

    Pashkevich, V. V.

    2008-04-01

    The last years a lot of attempts to derive a high-precision theory of the non-rigid Earth rotation was carried out. For these purposes the different transfer functions are used. Usually these transfer func- tions are applied to the series representing the nutation in longitude and in obliquity of the rigid Earth rotation with respect to the ecliptic of date. The aim of this investigation is a construction of the new high- precision non-rigid Earth rotation series (SN9000), dynamically adequate to the DE404/LE404 ephemeris over 2000 years, which are expressed as a function of Euler angles ψ, θ and φ with respect to the fixed ecliptic plane and equinox J2000.0. The early stages of the previous investigation: 1. The high-precision numerical solution of the rigid Earth rotation have been constructed (V.V.Pashkevich, G.I.Eroshkin and A.Brzezinski, 2004), (V.V.Pashkevich and G.I.Eroshkin, Proceedings of Journees 2004). The initial con- ditions have been calculated from SMART97 (P.Bretagnon, G.Francou, P.Rocher, J.L.Simon,1998). The discrepancies between the numerical solution and the semi-analytical solution SMART97 were obtained in Euler angles over 2000 years with one-day spacing. 2. Investigation of the discrepancies is carried out by the least squares and by the spectral analysis algorithms (V.V.Pashkevich and G.I.Eroshkin, Proceedings of Journees 2005). The high-precision rigid Earth rotation series S9000 are determined (V.V.Pashkevich and G.I.Eroshkin, 2005 ). The next stage of this investigation: 3. The new high-precision non-rigid Earth rotation series (SN9000), which are expressed as a function of Euler angles, are constructed by using the method (P.Bretagnon, P.M.Mathews, J.-L.Simon: 1999) and the transfer function MHB2002 (Mathews, P. M., Herring, T. A., and Buffett B. A., 2002).

  16. Deposition and Characterization of HVOF Thermal Sprayed Functionally Graded Coatings Deposited onto a Lightweight Material

    NASA Astrophysics Data System (ADS)

    Hasan, M.; Stokes, J.; Looney, L.; Hashmi, M. S. J.

    2009-02-01

    There is a significant interest in lightweight materials (like aluminum, magnesium, titanium, and so on) containing a wear resistance coating, in such industries as the automotive industry, to replace heavy components with lighter parts in order to decrease vehicle weight and increase fuel efficiency. Functionally graded coatings, in which the composition, microstructure, and/or properties vary gradually from the bond coat to the top coat, may be applied to lightweight materials, not only to decrease weight, but also to enhance components mechanical properties by ensuring gradual microstructural (changes) together with lower residual stress. In the current work, aluminum/tool-steel functionally graded coatings were deposited onto lightweight aluminum substrates. The graded coatings were then characterized in terms of residual stress and hardness. Results show that residual stress increased with an increase in deposition thickness and a decrease in number of layers. However, the hardness also increased with an increase in deposition thickness and decrease in number of layers. Therefore, an engineer must compromise between the hardness and stress values while designing a functionally graded coating-substrate system.

  17. Three-Dimensional Visualization of Wave Functions for Rotating Molecule: Plot of Spherical Harmonics

    ERIC Educational Resources Information Center

    Nagaoka, Shin-ichi; Teramae, Hiroyuki; Nagashima, Umpei

    2013-01-01

    At an early stage of learning quantum chemistry, undergraduate students usually encounter the concepts of the particle in a box, the harmonic oscillator, and then the particle on a sphere. Rotational levels of a diatomic molecule can be well approximated by the energy levels of the particle on a sphere. Wave functions for the particle in a…

  18. Thermo-Electro-Mechanical Analysis of a Curved Functionally Graded Piezoelectric Actuator with Sandwich Structure

    PubMed Central

    Yan, Zhi; Zaman, Mostafa; Jiang, Liying

    2011-01-01

    In this work, the problem of a curved functionally graded piezoelectric (FGP) actuator with sandwich structure under electrical and thermal loads is investigated. The middle layer in the sandwich structure is functionally graded with the piezoelectric coefficient g31 varying continuously along the radial direction of the curved actuator. Based on the theory of linear piezoelectricity, analytical solutions are obtained by using Airy stress function to examine the effects of material gradient and heat conduction on the performance of the curved actuator. It is found that the material gradient and thermal load have significant influence on the electroelastic fields and the mechanical response of the curved FGP actuator. Without the sacrifice of actuation deflection, smaller internal stresses are generated by using the sandwich actuator with functionally graded piezoelectric layer instead of the conventional bimorph actuator. This work is very helpful for the design and application of curved piezoelectric actuators under thermal environment. PMID:28824130

  19. Micromechanics and Structural Response of Functionally Graded, Particulate-Matrix, Fiber-Reinforced Composites

    PubMed Central

    Genin, Guy M.; Birman, Victor

    2009-01-01

    Reinforcement of fibrous composites by stiff particles embedded in the matrix offers the potential for simple, economical functional grading, enhanced response to mechanical loads, and improved functioning at high temperatures. Here, we consider laminated plates made of such a material, with spherical reinforcement tailored by layer. The moduli for this material lie within relatively narrow bounds. Two separate moduli estimates are considered: a “two-step” approach in which fibers are embedded in a homogenized particulate matrix, and the Kanaun-Jeulin (2001) approach, which we re-derive in a simple way using the Benveniste (1988) method. Optimal tailoring of a plate is explored, and functional grading is shown to improve the performance of the structures considered. In the example of a square, simply supported, cross-ply laminated panel subjected to uniform transverse pressure, a modest functional grading offers significant improvement in performance. A second example suggests superior blast resistance of the panel achieved at the expense of only a small increase in weight. PMID:23874001

  20. Milky Way Mass Models and MOND

    NASA Astrophysics Data System (ADS)

    McGaugh, Stacy S.

    2008-08-01

    Using the Tuorla-Heidelberg model for the mass distribution of the Milky Way, I determine the rotation curve predicted by MOND (modified Newtonian dynamics). The result is in good agreement with the observed terminal velocities interior to the solar radius and with estimates of the Galaxy's rotation curve exterior thereto. There are no fit parameters: given the mass distribution, MOND provides a good match to the rotation curve. The Tuorla-Heidelberg model does allow for a variety of exponential scale lengths; MOND prefers short scale lengths in the range 2.0 kpc lesssim Rdlesssim 2.5 kpc. The favored value of Rd depends somewhat on the choice of interpolation function. There is some preference for the "simple" interpolation function as found by Famaey & Binney. I introduce an interpolation function that shares the advantages of the simple function on galaxy scales while having a much smaller impact in the solar system. I also solve the inverse problem, inferring the surface mass density distribution of the Milky Way from the terminal velocities. The result is a Galaxy with "bumps and wiggles" in both its luminosity profile and rotation curve that are reminiscent of those frequently observed in external galaxies.

  1. Decoupled scheme based on the Hermite expansion to construct lattice Boltzmann models for the compressible Navier-Stokes equations with arbitrary specific heat ratio.

    PubMed

    Hu, Kainan; Zhang, Hongwu; Geng, Shaojuan

    2016-10-01

    A decoupled scheme based on the Hermite expansion to construct lattice Boltzmann models for the compressible Navier-Stokes equations with arbitrary specific heat ratio is proposed. The local equilibrium distribution function including the rotational velocity of particle is decoupled into two parts, i.e., the local equilibrium distribution function of the translational velocity of particle and that of the rotational velocity of particle. From these two local equilibrium functions, two lattice Boltzmann models are derived via the Hermite expansion, namely one is in relation to the translational velocity and the other is connected with the rotational velocity. Accordingly, the distribution function is also decoupled. After this, the evolution equation is decoupled into the evolution equation of the translational velocity and that of the rotational velocity. The two evolution equations evolve separately. The lattice Boltzmann models used in the scheme proposed by this work are constructed via the Hermite expansion, so it is easy to construct new schemes of higher-order accuracy. To validate the proposed scheme, a one-dimensional shock tube simulation is performed. The numerical results agree with the analytical solutions very well.

  2. Dynamic slip of polydisperse linear polymers using partitioned plate

    NASA Astrophysics Data System (ADS)

    Ebrahimi, Marzieh; Konaganti, Vinod Kumar; Hatzikiriakos, Savvas G.

    2018-03-01

    The slip velocity of an industrial grade high molecular weight high-density polyethylene (HDPE) is studied in steady and dynamic shear experiments using a stress/strain controlled rotational rheometer equipped with a parallel partitioned plate geometry. Moreover, fluoroalkyl silane-based coating is used to understand the effect of surface energy on slip in steady and dynamic conditions. The multimode integral Kaye-Bernstein-Kearsley-Zapas constitutive model is applied to predict the transient shear response of the HDPE melt obtained from rotational rheometer. It is found that a dynamic slip model with a slip relaxation time is needed to adequately predict the experimental data at large shear deformations. Comparison of the results before and after coating shows that the slip velocity is largely affected by surface energy. Decreasing surface energy by coating increases slip velocity and decreases the slip relaxation time.

  3. [Eccentric strength training for the rotator cuff tendinopathies with subacromial impingement. Current evidence].

    PubMed

    Macías-Hernández, Salvador Israel; Pérez-Ramírez, Luis Enrique

    2015-01-01

    Rotator cuff tears are the leading cause of pain and functional disability of the shoulder. Conservative treatment is an essential part of their management. Despite the limited evidence, rehabilitation is the mainstay of the treatment for rotator cuff tears associated to impingement syndrome. There are current reports on the utility of strengthening with resistance, particularly by eccentric exercise. This report aims to present an overview of the efficacy of eccentric exercises in tendinopathies and current evidence of its benefit in rotator cuff tears. We describe the information available in tendinopathy and analyzed four studies published on eccentric strengthening for rotator cuff tears. There is theoretical evidence about its usefulness in this pathology, but only a controlled clinical trial has been published with data on improvement in strength but not in pain or functionality. More studies are needed with better methodological designs in order to generate evidence of their utility and recommendation. Copyright © 2015. Published by Masson Doyma México S.A.

  4. Vortical features for myocardial rotation assessment in hypertrophic cardiomyopathy using cardiac tagged magnetic resonance.

    PubMed

    Sanz-Estébanez, Santiago; Cordero-Grande, Lucilio; Sevilla, Teresa; Revilla-Orodea, Ana; de Luis-García, Rodrigo; Martín-Fernández, Marcos; Alberola-López, Carlos

    2018-07-01

    Left ventricular rotational motion is a feature of normal and diseased cardiac function. However, classical torsion and twist measures rely on the definition of a rotational axis which may not exist. This paper reviews global and local rotation descriptors of myocardial motion and introduces new curl-based (vortical) features built from tensorial magnitudes, intended to provide better comprehension about fibrotic tissue characteristics mechanical properties. Fifty-six cardiomyopathy patients and twenty-two healthy volunteers have been studied using tagged magnetic resonance by means of harmonic phase analysis. Rotation descriptors are built, with no assumption about a regular geometrical model, from different approaches. The extracted vortical features have been tested by means of a sequential cardiomyopathy classification procedure; they have proven useful for the regional characterization of the left ventricular function by showing great separability not only between pathologic and healthy patients but also, and specifically, between heterogeneous phenotypes within cardiomyopathies. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Delamination Analysis of a Multilayered Two-Dimensional Functionally Graded Cantilever Beam

    NASA Astrophysics Data System (ADS)

    Rizov, V.

    2017-11-01

    Delamination fracture behaviour of a multilayered two-dimensional functionally graded cantilever beam is analyzed in terms of the strain energy release rate. The beam is made of an arbitrary number of layers. Perfect adhesion is assumed between layers. Each layer has individual thickness and material properties. Besides, the material is two-dimensional functionally graded in the cross-section of each layer. There is a delamination crack located arbitrary between layers. The beam is loaded by a bending moment applied at the free end of the lower crack arm. The upper crack arm is free of stresses. The solution to strain energy release rate derived is applied to investigate the influence of the crack location and the material gradient on the delamination fracture. The results obtained can be used to optimize the multilayered two-dimensional functionally graded beam structure with respect to the delamination fracture behaviour.

  6. EXERCISE REHABILITATION IN THE NON-OPERATIVE MANAGEMENT OF ROTATOR CUFF TEARS: A REVIEW OF THE LITERATURE

    PubMed Central

    Edwards, Peter; Ebert, Jay; Joss, Brendan; Bhabra, Gev; Ackland, Tim; Wang, Allan

    2016-01-01

    The incidence of rotator cuff tears increases with age, with full-thickness rotator cuff tears present in approximately 25% of individuals in their sixties, and more than 50% of those in their eighties. While surgery is considered an effective treatment, recurrent tears at the insertion site are common, especially with degenerative tears, which are frequent in the older population. More recently, there has been increasing interest in exercise rehabilitation and physical therapy as a means to manage partial and full thickness tears of the rotator cuff by addressing weakness and functional deficits. Recent studies have suggested that patients opting for physical therapy have demonstrated high satisfaction, an improvement in function, and success in avoiding surgery. When considering the increasing rate of shoulder surgery and the associated economic and social burden rotator cuff surgery places on both the patient and the health care system, non-surgical management such as physical therapy and exercise may, in selected cases, be a treatment alternative to surgical repair. The purpose of this clinical commentary is to provide an overview of rotator cuff pathology and pathogenesis, and to present an evidence-based case for the role of conservative rehabilitation in the management of rotator cuff injuries. Level of Evidence Level 5 PMID:27104061

  7. Unveiling the mechanism of the promising two-dimensional photoswitch - Hemithioindigo

    NASA Astrophysics Data System (ADS)

    Li, Donglin; Yang, Yonggang; Li, Chaozheng; Liu, Yufang

    2018-07-01

    The control of internal molecular motions by outside stimuli is a decisive task in the construction of functional molecules and molecular machines. Light-induced intramolecular rotations of photoswitches have attracted increasing research interests because of the high stability and high reversibility of photoswitches. Recently, Henry et al. reported an unprecedented two-dimensional controlled photoswitch, the hemithioindigo (HTI) derivative Z1, whose single bond rotation in dimethyl sulphoxide (DMSO) solvent and double bond rotation in cyclohexane solvent can be induced by visible light (J. Am. Chem. Soc. 2016, 138, 12,219). Here we investigate the intramolecular rotations of the HTI and Z1 in different polar solvents by time-dependent density functional theory (TDDFT) and Nonadiabatic dynamic simulations. Due to the steric hindrance between methyl and thioindigo fragment, the rotations of Z1 in the excited state are obstructed. Interestingly, the HTI exhibits two distinct rotation paths in DMSO and cyclohexane solvents at about 50 fs. The intermolecular hydrogen bonds between HTI and DMSO play an important role in the rotation of HTI in DMSO solvent. Therefore, the HTI is a more promising two-dimensional photoswitch compared with the Z1. Our finding is thus of fundamental importance to understand the mechanisms of this class of photoswitches and design complex molecular behavior.

  8. How to derotate the cosmic microwave background polarization.

    PubMed

    Kamionkowski, Marc

    2009-03-20

    If the linear polarization of the cosmic microwave background is rotated in a frequency-independent manner as it propagates from the surface of last scatter, it may introduce a B-mode polarization. Here I show that measurement of higher-order TE, EE, EB, and TB correlations induced by this rotation can be used to reconstruct the rotation angle as a function of position on the sky. This technique can be used to distinguish primordial B modes from those induced by rotation. The effects of rotation can be distinguished geometrically from similar effects due to cosmic shear.

  9. Understanding Linear Functions and Their Representations

    ERIC Educational Resources Information Center

    Wells, Pamela J.

    2015-01-01

    Linear functions are an important part of the middle school mathematics curriculum. Students in the middle grades gain fluency by working with linear functions in a variety of representations (NCTM 2001). Presented in this article is an activity that was used with five eighth-grade classes at three different schools. The activity contains 15 cards…

  10. The association between sleep disordered breathing, academic grades, and cognitive and behavioral functioning among overweight subjects during middle to late childhood.

    PubMed

    Beebe, Dean W; Ris, M Douglas; Kramer, Megan E; Long, Elizabeth; Amin, Raouf

    2010-11-01

    (1) to determine the associations of sleep disordered breathing (SDB) with behavioral functioning, cognitive test scores, and school grades during middle- to late-childhood, an under-researched developmental period in the SDB literature, and (2) to clarify whether associations between SDB and school grades are mediated by deficits in cognitive or behavioral functioning. cross-sectional correlative study. Office/hospital, plus reported functioning at home and at school. 163 overweight subjects aged 10-16.9 years were divided into 4 groups based upon their obstructive apnea+hypopnea index (AHI) during overnight polysomnography and parent report of snoring: Moderate-Severe OSA (AHI > 5, n = 42), Mild OSA (AHI = 1-5, n = 58), Snorers (AHI < 1 + snoring, n = 26), and No SDB (AHI < 1 and nonsnoring, n = 37). inpatient overnight polysomnography, parent- and self-report of school grades and sleep, parent- and teacher-report of daytime behaviors, and office-based neuropsychological testing. The 4 groups significantly differed in academic grades and parent- and teacher-reported behaviors, particularly inattention and learning problems. These findings remained significant after adjusting for subject sex, race, socioeconomic status, and school night sleep duration. Associations with SDB were confined to reports of behavioral difficulties in real-world situations, and did not extend to office-based neuropsychological tests. Findings from secondary analyses were consistent with, but could not definitively confirm, a causal model in which SDB affects school grades via its impact on behavioral functioning. SDB during middle- to late-childhood is related to important aspects of behavioral functioning, especially inattention and learning difficulties, that may result in significant functional impairment at school.

  11. A randomised trial into the effect of an isolated hip abductor strengthening programme and a functional motor control programme on knee kinematics and hip muscle strength.

    PubMed

    Palmer, Kathryn; Hebron, Clair; Williams, Jonathan M

    2015-05-03

    Dynamic knee valgus and internal femoral rotation are proposed to be contributory risk factors for patellofemoral pain and anterior cruciate ligament injuries. Multimodal interventions including hip abductor strengthening or functional motor control programmes have a positive impact of pain, however their effect on knee kinematics and muscle strength is less clear. The aim of this study was to examine the effect of isolated hip abductor strengthening and a functional motor control exercise on knee kinematics and hip abductor strength. This prospective, randomised, repeated measures design included 29 asymptomatic volunteers presenting with increase knee valgus and femoral internal rotation. Participants completed either isolated hip abductor strengthening or a functional motor control exercise for 5 weeks. Knee kinematics were measured using inertial sensors during 2 functional activities and hip abductor strength measured using a load cell during isometric hip abduction. There were no significant differences in dynamic knee valgus and internal rotation following the isolated hip abductor or functional motor control intervention, and no significant differences between the groups for knee angles. Despite this, the actual magnitude of reduction in valgus was 10° and 5° for the functional motor control group and strengthening group respectively. The actual magnitude of reduction in internal rotation was 9° and 18° for the functional motor control group and strengthening group respectively. Therefore there was a tendency towards clinically significant improvements in knee kinematics in both exercise groups. A statistically significant improvement in hip abductor strength was evident for the functional motor control group (27% increase; p = 0.008) and strengthening group (35% increase; p = 0.009) with no significant difference between the groups being identified (p = 0.475). Isolated hip strengthening and functional motor control exercises resulted in non-statistically significant changes in knee kinematics, however there was a clear trend towards clinically meaningful reductions in valgus and internal rotation. Both groups demonstrated similar significant gains in hip abductor strength suggesting either approach could be used to strengthen the hip abductors.

  12. Probing molecular potentials with an optical centrifuge.

    PubMed

    Milner, A A; Korobenko, A; Hepburn, J W; Milner, V

    2017-09-28

    We use an optical centrifuge to excite coherent rotational wave packets in N 2 O, OCS, and CS 2 molecules with rotational quantum numbers reaching up to J≈465, 690, and 1186, respectively. Time-resolved rotational spectroscopy at such ultra-high levels of rotational excitation can be used as a sensitive tool to probe the molecular potential energy surface at internuclear distances far from their equilibrium values. Significant bond stretching in the centrifuged molecules results in the growing period of the rotational revivals, which are experimentally detected using coherent Raman scattering. We measure the revival period as a function of the centrifuge-induced rotational frequency and compare it with the numerical calculations based on the known Morse-cosine potentials.

  13. Probing molecular potentials with an optical centrifuge

    NASA Astrophysics Data System (ADS)

    Milner, A. A.; Korobenko, A.; Hepburn, J. W.; Milner, V.

    2017-09-01

    We use an optical centrifuge to excite coherent rotational wave packets in N2O, OCS, and CS2 molecules with rotational quantum numbers reaching up to J ≈465 , 690, and 1186, respectively. Time-resolved rotational spectroscopy at such ultra-high levels of rotational excitation can be used as a sensitive tool to probe the molecular potential energy surface at internuclear distances far from their equilibrium values. Significant bond stretching in the centrifuged molecules results in the growing period of the rotational revivals, which are experimentally detected using coherent Raman scattering. We measure the revival period as a function of the centrifuge-induced rotational frequency and compare it with the numerical calculations based on the known Morse-cosine potentials.

  14. A patient-specific model of the biomechanics of hip reduction for neonatal Developmental Dysplasia of the Hip: Investigation of strategies for low to severe grades of Developmental Dysplasia of the Hip.

    PubMed

    Huayamave, Victor; Rose, Christopher; Serra, Sheila; Jones, Brendan; Divo, Eduardo; Moslehy, Faissal; Kassab, Alain J; Price, Charles T

    2015-07-16

    A physics-based computational model of neonatal Developmental Dysplasia of the Hip (DDH) following treatment with the Pavlik Harness (PV) was developed to obtain muscle force contribution in order to elucidate biomechanical factors influencing the reduction of dislocated hips. Clinical observation suggests that reduction occurs in deep sleep involving passive muscle action. Consequently, a set of five (5) adductor muscles were identified as mediators of reduction using the PV. A Fung/Hill-type model was used to characterize muscle response. Four grades (1-4) of dislocation were considered, with one (1) being a low subluxation and four (4) a severe dislocation. A three-dimensional model of the pelvis-femur lower limb of a representative 10 week-old female was generated based on CT-scans with the aid of anthropomorphic scaling of anatomical landmarks. The model was calibrated to achieve equilibrium at 90° flexion and 80° abduction. The hip was computationally dislocated according to the grade under investigation, the femur was restrained to move in an envelope consistent with PV restraints, and the dynamic response under passive muscle action and the effect of gravity was resolved. Model results with an anteversion angle of 50° show successful reduction Grades 1-3, while Grade 4 failed to reduce with the PV. These results are consistent with a previous study based on a simplified anatomically-consistent synthetic model and clinical reports of very low success of the PV for Grade 4. However our model indicated that it is possible to achieve reduction of Grade 4 dislocation by hyperflexion and the resultant external rotation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. An Analysis of Turnover Intentions: A Reexamination of Air Force Civil Engineering Company Grade Officers

    DTIC Science & Technology

    2012-03-01

    edu 75 Appendix C Factor Analysis of Measurement Items Interrole conflict Factor Analysis (FA): Table: KMO and Bartlett’s Test Kaiser-Meyer...Extraction Method: Principal Component Analysis. Rotation Method: Varimax with Kaiser Normalization. 77 POS FA: Table: KMO and Bartlett’s...Tempo FA: Table: KMO and Bartlett’s Test Kaiser-Meyer-Olkin Measure of Sampling Adequacy. .733 Bartlett’s Test of Sphericity Approx. Chi-Square

  16. Cole-Davidson dynamics of simple chain models.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dotson, Taylor C.; McCoy, John Dwane; Adolf, Douglas Brian

    2008-10-01

    Rotational relaxation functions of the end-to-end vector of short, freely jointed and freely rotating chains were determined from molecular dynamics simulations. The associated response functions were obtained from the one-sided Fourier transform of the relaxation functions. The Cole-Davidson function was used to fit the response functions with extensive use being made of Cole-Cole plots in the fitting procedure. For the systems studied, the Cole-Davidson function provided remarkably accurate fits [as compared to the transform of the Kohlrausch-Williams-Watts (KWW) function]. The only appreciable deviations from the simulation results were in the high frequency limit and were due to ballistic or freemore » rotation effects. The accuracy of the Cole-Davidson function appears to be the result of the transition in the time domain from stretched exponential behavior at intermediate time to single exponential behavior at long time. Such a transition can be explained in terms of a distribution of relaxation times with a well-defined longest relaxation time. Since the Cole-Davidson distribution has a sharp cutoff in relaxation time (while the KWW function does not), it makes sense that the Cole-Davidson would provide a better frequency-domain description of the associated response function than the KWW function does.« less

  17. Association of Leukoaraiosis With Convalescent Rehabilitation Outcome in Patients With Ischemic Stroke.

    PubMed

    Senda, Joe; Ito, Keiichi; Kotake, Tomomitsu; Kanamori, Masahiko; Kishimoto, Hideo; Kadono, Izumi; Suzuki, Yoshiro; Katsuno, Masahisa; Nishida, Yoshihiro; Ishiguro, Naoki; Sobue, Gen

    2016-01-01

    We investigated the factors influencing inpatient convalescent rehabilitation outcomes in patients with ischemic stroke, particularly severity of leukoaraiosis on magnetic resonance imaging. Participants included 520 patients with ischemic stroke (317 men and 203 women; mean age, 72.8±8.4 years) who were transferred from acute care hospitals for inpatient convalescent rehabilitation. Ischemic stroke subtypes included lacunar infarction (n=41), atherothrombosis (n=223), artery-to-artery embolism (n=67), cardiogenic embolism (n=97), undetermined embolism (n=76), and uncategorized ischemic stroke (n=16). Leukoaraiosis was graded according to periventricular hyperintensity (PVH) and deep white matter hyperintensity on magnetic resonance imaging. Functional Independence Measure scores were assessed on admission and at discharge. Multiple regression analysis revealed that rehabilitation outcomes, measured as total Functional Independence Measure scores, were significantly associated with leukoaraiosis estimated by PVH grade. This association was observed after adjustment for factors such as severity, age, and poststroke history. In all patients, PVH grades were associated with Functional Independence Measure motor scores (P<0.001), whereas in patients with artery-to-artery embolism or cardiogenic embolism and deep white matter hyperintensity grades were associated with Functional Independence Measure cognitive scores (P<0.05). Our study revealed that the degree of leukoaraiosis was associated with inpatient convalescent rehabilitation outcome in patients with ischemic stroke. Furthermore, the PVH grade was associated with motor function outcome, whereas the deep white matter hyperintensity grade correlated with cognitive function outcome, likely because the progression patterns and anatomic backgrounds of PVH and deep white matter hyperintensity differ according to ischemic stroke subtype. © 2015 American Heart Association, Inc.

  18. Correlation of resting and exercising endoscopic findings for horses with dynamic laryngeal collapse and palatal dysfunction.

    PubMed

    Barakzai, S Z; Dixon, P M

    2011-01-01

    To correlate resting and exercising endoscopic grades of laryngeal function in horses undergoing high-speed treadmill endoscopy (HSTE) using the Havemeyer grading system. To correlate dorsal displacement of the soft palate (DDSP) seen at rest with palatal function during exercise. Records of horses that underwent HSTE examination (1999-2009) were reviewed. Resting laryngeal function score and other abnormalities noted on resting endoscopy were recorded as were results of HSTE. Results of resting and exercising endoscopic findings were correlated. 281 horses underwent HSTE. There was significant correlation between grade of laryngeal function at rest (grades 1-4) and exercise (ρ=0.53, P<0.001) and between resting subgrades 3.1, 3.2 and 3.3 and exercising grades of laryngeal function (ρ=0.43, P=0.0017). DDSP was observed at rest significantly more often in horses that developed DDSP during HSTE than those without DDSP during HSTE (RR=4.1, P<0.001). The sensitivity and specificity of DDSP seen during resting endoscopy as a test for DDSP occurring during exercise were 25.5 and 95.1% respectively (positive predictive value 0.57, negative predictive value 0.83). The results of the current study support the use of the Havemeyer system for grading laryngeal function in the resting horse, and corroborate findings of previous studies correlating resting and exercising palatal abnormalities. Studies that use the presence of spontaneous DDSP during resting endoscopic examination as an inclusion criterion for investigating efficacy of treatments for DDSP are likely to have a low proportion of horses with false positive diagnoses. © 2010 EVJ Ltd.

  19. Isometric hip-rotator torque production at varying degrees of hip flexion.

    PubMed

    Johnson, Sam; Hoffman, Mark

    2010-02-01

    Hip torque production is associated with certain knee injuries. The hip rotators change function depending on hip angle. To compare hip-rotator torque production between 3 angles of hip flexion, limbs, and sexes. Descriptive. University sports medicine research laboratory. 15 men and 15 women, 19-39 y. Three 6-s maximal isometric contractions of the hip external and internal rotators at 10 degrees, 40 degrees, and 90 degrees of hip flexion on both legs. Average torque normalized to body mass. Internal-rotation torque was greatest at 90 degrees of hip flexion, followed by 40 degrees of hip flexion and finally 10 degrees of hip flexion. External-rotation torque was not different based on hip flexion. The nondominant leg's external rotators were stronger than the dominant leg's, but the reverse was true for internal rotators. Finally, the men had more overall rotator torque. Hip-rotation torque production varies between flexion angle, leg, and sex. Clinicians treating lower extremity problems need to be aware of these differences.

  20. A two-in-one Faraday rotator mirror exempt of active optical alignment.

    PubMed

    Wan, Qiong; Wan, Zhujun; Liu, Hai; Liu, Deming

    2014-02-10

    A two-in-one Faraday rotator mirror was presented, which functions as two independent Faraday rotation mirrors with a single device. With the introduction of a reflection lens as substitution of the mirror in traditional structure, this device is characterized by exemption of active optical alignment for the designers and manufacturers of Faraday rotator mirrors. A sample was fabricated by passive mechanical assembly. The insertion loss was measured as 0.46 dB/0.50 dB for the two independent ports, respectively.

  1. Does Grading Affect Educational Attainment? A Longitudinal Study

    ERIC Educational Resources Information Center

    Klapp, Alli

    2015-01-01

    The purpose of the study was to investigate how grading in primary school affected students' achievement measured by grades in 7th, 8th and 9th Grade and educational attainment in upper secondary school (12th Grade), and how the effect varied as a function of students' cognitive ability, gender and socio-economic status. The data derived from the…

  2. Parent-reported cognitive function is associated with leukoencephalopathy in children with brain tumors.

    PubMed

    Lai, Jin-Shei; Bregman, Corey; Zelko, Frank; Nowinski, Cindy; Cella, David; Beaumont, Jennifer J; Goldman, Stewart

    2017-09-01

    Cognitive dysfunction is a major concern for children with brain tumors. A valid, user-friendly screening tool could facilitate prompt referral for comprehensive neuropsychological assessments and therefore early intervention. Applications of the pediatric perceived cognitive function item bank (pedsPCF) such as computerized adaptive testing can potentially serve as such a tool given its brevity and user-friendly nature. This study aimed to evaluate whether pedsPCF was a valid indicator of cerebral compromise using the criterion of structural brain changes indicated by leukoencephalopathy grades. Data from 99 children (mean age = 12.6 years) with brain tumors and their parents were analyzed. Average time since diagnosis was 5.8 years; time since last treatment was 4.3 years. Leukoencephalopathy grade (range 0-4) was based on white matter damage and degree of deep white matter volume loss shown on MRI. Parents of patients completed the pedsPCF. Scores were based on the US general population-based T-score metric (mean = 50; SD = 10). Higher scores reflect better function. Leukoencephalopathy grade distributions were as follows: 36 grade 0, 27 grade 1, 22 grade 2, 13 grade 3, and 1 grade 4. The mean pedsPCF T-score was 48.3 (SD = 8.3; range 30.5-63.7). The pedsPCF scores significantly discriminated patients with different leukoencephalopathy grades, F = 4.14, p = 0.0084. Effect sizes ranged from 0.09 (grade 0 vs. 1) to 1.22 (grade 0 vs. 3/4). This study demonstrates that the pedsPCF is a valid indicator of leukoencephalopathy and provides support for its use as a screening tool for more comprehensive neurocognitive testing.

  3. Differentials in Turnout Among Professional Classical Ballet Dancers.

    PubMed

    Washington, Isobel; Mayes, Susan; Ganderton, Charlotte; Pizzari, Tania

    2016-09-01

    Screening and training of professional dancers is commonly based around beliefs that a large range of turnout is more advantageous in the ballet industry. This belief leads dancers who have limited hip external rotation to compensate by forcing turnout at the knee and ankle, which has been linked to injury. To examine if there is a difference in degree of turnout between three levels of dancers (corps, soloist, principal) in a professional classical ballet company. An additional aim was to establish average values for the range of turnout and hip rotation present in the dancers. Forty-five professional dancers from The Australian Ballet (25 female, 20 male) participated in the study. Active and passive hip external rotation (hip ER) was measured in supine using inclinometers, and functional turnout in ballet first position (lower limb external rotation, LLER) was measured using foot traces utilising bony landmarks. Below-hip external rotation (BHER) was also calculated. No relationship was found among level of dancer and passive hip ER, active hip ER, LLER, and BHER. Professional dancers had on average 50.2° of passive hip ER range, 35.2° of active hip ER, and 133.6° of functional turnout position. In addition, no correlation was found between LLER and hip ER, but significant correlations were found between LLER and BHER. Hip rotation range of motion is similar across all levels of professional dancers. Average values for passive and active hip ER and functional turnout were established.

  4. Collision energy dependent cross section and rotational alignment of NO (A 2Σ+) in the energy-transfer reaction of N2 (A 3Σu+) + NO (X 2Π) → N2 (X 1Σg+) + NO (A 2Σ+).

    PubMed

    Ohoyama, H

    2014-10-16

    We have studied the collision energy dependent cross section and alignment of NO (A (2)Σ(+)) rotation in the energy-transfer reaction of N2 (A (3)Σ(u)(+)) + NO (X (2)Π) → N2 (X (1)Σ(g)(+)) + NO (A (2)Σ(+)) at the collision energy (E) region of 0.03-0.2 eV. NO (A (2)Σ(+)) emission in two linear polarization directions in the collision frame (parallel (∥) and perpendicular (⊥) with respect to the relative velocity vector (vR)) has been measured as a function of collision energy. NO (A (2)Σ(+)) rotation (J-vector) turns out to be aligned perpendicular to vR. In addition, collision energy is found to enhance the degree of alignment of NO (A (2)Σ(+)) rotation. The collision energy dependent cross sections σ(∥,(⊥))(E) (excitation functions) show a rapid fall-off following an initial rise with a threshold less than 0.02 eV. The excitation function at the parallel alignment of NO (A (2)Σ(+)) rotation, σ(J∥v(R), (E), is slightly shifted to the low collision energy region as compared with σ(J ⊥ vR, E). We propose that the rapid fall-off feature in the excitation function is attributed to the multidimensional nonadiabatic transitions.

  5. Collegiate Grading Practices and the Gender Pay Gap.

    ERIC Educational Resources Information Center

    Dowd, Alicia C.

    2000-01-01

    Presents a theoretical analysis showing that relatively low grading quantitative fields and high grading verbal fields create a disincentive for college women to invest in quantitative study. Extends research by R. Sabot and J. Wakeman-Linn. Models pressures on grading practices using higher education production functions. (Author/SLD)

  6. Parental Autonomy Granting and School Functioning among Chinese Adolescents: The Moderating Role of Adolescents’ Cultural Values

    PubMed Central

    Wang, Cixin; Do, Kieu Anh; Bao, Leiping; Xia, Yan R.; Wu, Chaorong

    2017-01-01

    School adjustment and achievement are important indicators of adolescents’ well-being; however, few studies have examined the risk and protective factors predicting students’ school adjustment and achievement at the individual, familial, and cultural level. The present study examined the influences of individual and familial factors and cultural values on Chinese adolescents’ school functioning (e.g., school adjustment and grades). It also tested whether cultural values moderated the relationship between parenting and adolescents’ school functioning. Self-report data were collected from a stratified random sample of 2,864 adolescents (51.5% female, mean age = 15.52 years, grade 6th – 12th) from 55 classrooms, in 13 schools in Shanghai, China. Results showed that self-esteem (bse→adj = 0.05, SE = 0.01, p < 0.001; bse→grades = 0.08, SE = 0.02, p < 0.001), parent–adolescent conflict (bconflict→adj = -0.03, SE = 0.00, p < 0.001; bconflict→grades = -0.04, SE = 0.01, p < 0.001), and conformity to parental expectations (bconform→adj = -0.03, SE = 0.02, p < 0.05; bconform→grades = 0.10, SE = 0.04, p < 0.05) all had significant effects on both school adjustment and grades, respectively. More importantly, results showed that independent self-construal moderated the relationship between parental autonomy granting and adolescents’ grades (bindepxautom = 0.06, SE = 0.02, p < 0.01). The findings suggest that cultural values may influence adolescents’ appraisal of parental autonomy granting, which then impacts their school functioning. PMID:29326622

  7. Anatomical grades of nerve sparing: a risk-stratified approach to neural-hammock sparing during robot-assisted radical prostatectomy (RARP).

    PubMed

    Tewari, Ashutosh K; Srivastava, Abhishek; Huang, Michael W; Robinson, Brian D; Shevchuk, Maria M; Durand, Matthieu; Sooriakumaran, Prasanna; Grover, Sonal; Yadav, Rajiv; Mishra, Nishant; Mohan, Sanjay; Brooks, Danielle C; Shaikh, Nusrat; Khanna, Abhinav; Leung, Robert

    2011-09-01

    • To report the potency and oncological outcomes of patients undergoing robot-assisted radical prostatectomy (RARP) using a risk-stratified approach based on layers of periprostatic fascial dissection. • We also describe the surgical technique of complete hammock preservation or nerve sparing grade 1. • This is a retrospective study of 2317 patients who had robotic prostatectomy by a single surgeon at a single institution between January 2005 and June 2010. • Included patients were those with ≥ 1 year of follow-up and who were potent preoperatively, defined as having a sexual health inventory for men (SHIM) questionnaire score of >21; thus, the final number of patients in the study cohort was 1263. • Patients were categorized pre-operatively by a risk-stratified approach into risk grades 1-4, where risk grade 1 patients received nerve-sparing grade 1 or complete hammock preservation and so on for risk grades 2-4, as long as intraoperative findings permitted the planned nerve sparing. • We considered return to sexual function post-operatively by two criteria: i) ability to have successful intercourse (score of ≥ 4 on question 2 of the SHIM) and ii) SHIM >21 or return to baseline sexual function. • There was a significant difference across different NS grades in terms of the percentages of patients who had intercourse and returned to baseline sexual function (P < 0.001), with those that underwent NS grade 1 having the highest rates (90.9% and 81.7%) as compared to NS grades 2 (81.4% and 74.3%), 3 (73.5% and 66.1%), and 4 (62% and 54.5%). • The overall positive surgical margin (PSM) rates for patients with NS grades 1, 2, 3, and 4 were 9.9%, 8.1%, 7.2%, and 8.7%, respectively (P = 0.636). • The extraprostatic extension rates were 11.6%, 14.3%, 29.3%, and 36.2%, respectively (P < 0.001). • Similarly, in patients younger than 60, intercourse and return to baseline sexual function rates were 94.9% and 84.3% for NS grade 1 as compared to 85.5% and 77.2% for NS grades 2, 76.9% and 69% for NS grades 3, and 64.8% and 57.7% for NS Grade 4 (P < 0.001). • The risk-stratified approach and anatomical technique of neural-hammock sparing described in the present manuscript was effective in improving potency outcomes of patients without compromising cancer control. • Patients with greater degrees of NS had higher rates of intercourse and return to baseline sexual function without an increase in PSM rates. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  8. Children's Left Parietal Brain Activation during Mental Rotation Is Reliable as Well as Specific

    ERIC Educational Resources Information Center

    Heil, Martin; Jansen-Osmann, Petra

    2007-01-01

    Some recent evidence suggests that mental rotation of characters in children aged 7 or 8 years might be lateralized to the left parietal hemisphere. An alternative statement exists, however, the finding might be completely unspecific for mental rotation but either be simply a function of task difficulty or a consequence of the use of characters as…

  9. Outcomes assessment in rotator cuff pathology: what are we measuring?

    PubMed

    Makhni, Eric C; Steinhaus, Michael E; Morrow, Zachary S; Jobin, Charles M; Verma, Nikhil N; Cole, Brian J; Bach, Bernard R

    2015-12-01

    Assessments used to measure outcomes associated with rotator cuff pathology and after repair are varied. This lack of standardization leads to difficulty drawing comparisons across studies. We hypothesize that this variability in patient-reported outcome measures and objective metrics used in rotator cuff studies persists even in high-impact, peer reviewed journals. All studies assessing rotator cuff tear and repair outcomes in 6 orthopedic journals with a high impact factor from January 2010 to December 2014 were reviewed. Cadaveric and animal studies and those without outcomes were excluded. Outcome measures included range of motion (forward elevation, abduction, external rotation, and internal rotation), strength (in the same 4 planes), tendon integrity imaging, patient satisfaction, and functional assessment scores. Of the 156 included studies, 63% documented range of motion measurements, with 18% reporting range of motion in all 4 planes. Only 38% of studies reported quantitative strength measurements. In 65% of studies, tendon integrity was documented with imaging (38% magnetic resonance imaging/magnetic resonance anrhrogram, 31% ultrasound, and 8% computed tomography arthrogram). Finally, functional score reporting varied significantly, with the 5 most frequently reported scores ranging from 16% to 61% in studies, and 15 of the least reported outcomes were each reported in ≤6% of studies. Significant variability exists in outcomes reporting after rotator cuff tear and repair, making comparisons between clinical studies difficult. Creating a uniformly accepted, validated outcomes tool that assesses pain, function, patient satisfaction, and anatomic integrity would enable consistent outcomes assessment after operative and nonoperative management and allow comparisons across the literature. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. Long-term successful arthroscopic repair of large and massive rotator cuff tears with a functional and degradable reinforcement device.

    PubMed

    Proctor, Christopher S

    2014-10-01

    Rotator cuff repair is a procedure with varying outcomes, and there has been subsequent interest in devices that reinforce the repair and enhance structural and functional outcomes. The objective of this study was to determine these outcomes for arthroscopic repair of large and massive rotator cuff tears augmented with a synthetic absorbable mesh designed specifically for reinforcement of tendon repair by imaging and clinical assessments. Consecutive arthroscopic repairs were performed on 18 patients with large to massive rotator cuff tears by use of a poly-l-lactic acid synthetic patch as a reinforcement device and fixation with 4 sutures. Patients were assessed preoperatively and at 6 months, 12 months, and a mean of 42 months after surgery by the American Shoulder and Elbow Surgeons (ASES) shoulder score to evaluate clinical performance and at 12 months by ultrasound to assess structural repair. Ultrasound showed that 15 of 18 patients had intact rotator cuff repair at 12 months; at 42 months, an additional patient had a failed repair. Patients showed improvement in the ASES shoulder score from 25 preoperatively to 71 at 12 months and 70 at 42 months after surgery. Patients with intact rotator cuff (n = 14) at 42 months had an ASES shoulder score of 82. The poly-l-lactic acid bioabsorbable patch designed specifically to reinforce the surgical repair of tendons supported successful repair of large to massive rotator cuff tears in 83% of patients at 12 months after surgery and 78% of patients at 42 months after surgery, with substantial functional improvement. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Comparing surgical repair with conservative treatment for degenerative rotator cuff tears: a randomized controlled trial.

    PubMed

    Lambers Heerspink, Frederik O; van Raay, Jos J A M; Koorevaar, Rinco C T; van Eerden, Pepijn J M; Westerbeek, Robin E; van 't Riet, Esther; van den Akker-Scheek, Inge; Diercks, Ronald L

    2015-08-01

    Good clinical results have been reported for both surgical and conservative treatment of rotator cuff tears. The primary aim of this randomized controlled trial was to compare functional and radiologic improvement after surgical and conservative treatment of degenerative rotator cuff tears. We conducted a randomized controlled trial that included 56 patients with a degenerative full-thickness rotator cuff tear between January 2009 and December 2012; 31 patients were treated conservatively, and rotator cuff repair was performed in 25 patients. Outcome measures, including the Constant-Murley score (CMS), visual analog scale (VAS) pain and VAS disability scores, were assessed preoperatively and after 6 weeks and 3, 6, and 12 months. Magnetic resonance imaging was performed preoperatively and at 12 months postoperatively. At 12 months postoperatively, the mean CMS was 81.9 (standard deviation [SD], 15.6) in the surgery group vs 73.7 (SD, 18.4) in the conservative group (P = .08). VAS pain (P = .04) and VAS disability (P = .02) were significantly lower in the surgery group at the 12-month follow-up. A subgroup analysis showed postoperative CMS results were significantly better in surgically treated patients without a retear compared with conservatively treated patients (88.5 [SD, 6.2] vs 73.7 [SD, 18.4]). In our population of patients with degenerative rotator cuff tears who were randomly treated by surgery or conservative protocol, we did not observe differences in functional outcome as measured with the CMS 1 year after treatment. However, significant differences in pain and disabilities were observed in favor of surgical treatment. The best outcomes in function and pain were seen in patients with an intact rotator cuff postoperatively. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Hypervelocity Impact Test Fragment Modeling: Modifications to the Fragment Rotation Analysis and Lightcurve Code

    NASA Technical Reports Server (NTRS)

    Gouge, Michael F.

    2011-01-01

    Hypervelocity impact tests on test satellites are performed by members of the orbital debris scientific community in order to understand and typify the on-orbit collision breakup process. By analysis of these test satellite fragments, the fragment size and mass distributions are derived and incorporated into various orbital debris models. These same fragments are currently being put to new use using emerging technologies. Digital models of these fragments are created using a laser scanner. A group of computer programs referred to as the Fragment Rotation Analysis and Lightcurve code uses these digital representations in a multitude of ways that describe, measure, and model on-orbit fragments and fragment behavior. The Dynamic Rotation subroutine generates all of the possible reflected intensities from a scanned fragment as if it were observed to rotate dynamically while in orbit about the Earth. This calls an additional subroutine that graphically displays the intensities and the resulting frequency of those intensities as a range of solar phase angles in a Probability Density Function plot. This document reports the additions and modifications to the subset of the Fragment Rotation Analysis and Lightcurve concerned with the Dynamic Rotation and Probability Density Function plotting subroutines.

  13. Direction of flagellar rotation in bacterial cell envelopes.

    PubMed Central

    Ravid, S; Eisenbach, M

    1984-01-01

    Cell envelopes with functional flagella, isolated from wild-type strains of Escherichia coli and Salmonella typhimurium by formation of spheroplasts with penicillin and subsequent osmotic lysis, demonstrate counterclockwise (CCW)-biased rotation when energized with an electron donor for respiration, DL-lactate. Since the direction of flagellar rotation in bacteria is central to the expression of chemotaxis, we studied the cause of this bias. Our main observations were: (i) spheroplasts acquired a clockwise (CW) bias if instead of being lysed they were further incubated with penicillin; (ii) repellents temporarily caused CW rotation of tethered bacteria and spheroplasts but not of their derived cell envelopes; (iii) deenergizing CW-rotating cheV bacteria by KCN or arsenate treatment caused CCW bias; (iv) cell envelopes isolated from CW-rotating cheC and cheV mutants retained the CW bias, unlike envelopes isolated from cheB and cheZ mutants, which upon cytoplasmic release lost this bias and acquired CCW bias; and (v) an inwardly directed, artificially induced proton current rotated tethered envelopes in CCW direction, but an outwardly directed current was unable to rotate the envelopes. It is concluded that (i) a cytoplasmic constituent is required for the expression of CW rotation (or repression of CCW rotation) in strains which are not defective in the switch; (ii) in the absence of this cytoplasmic constituent, the motor is not reversible in such strains, and it probably is mechanically constricted so as to permit CCW sense of rotation only; (iii) the requirement of CW rotation for ATP is not at the level of the motor or the switch but at one of the preceding functional steps of the chemotaxis machinery; (iv) the cheC and cheV gene products are associated with the cytoplasmic membrane; and (v) direct interaction between the switch-motor system and the repellent sensors is improbable. Images PMID:6370958

  14. Diabetes mellitus increases the risk of rotator cuff tear repair surgery: A population-based cohort study.

    PubMed

    Huang, Shih-Wei; Wang, Wei-Te; Chou, Lin-Chuan; Liou, Tsan-Hon; Chen, Yi-Wen; Lin, Hui-Wen

    Rotator cuff tears are the most common cause of shoulder disability in people older than 50years, and surgical intervention is usually required for restoring functioning. However, in patients undergoing rotator cuff repair surgery, patients with DM had poorer functional outcomes than those without DM, and hence, DM is one of the possible risks factor for rotator cut off tear. The aim of this population-based study was to investigate the relationship between DM and the risk of rotator cuff tear in patients receiving rotator cuff repair surgery. In this retrospective longitudinal population-based 7-year cohort study, we investigated the risk of rotator cuff repair surgery in patients with DM. We performed a case-control matched analysis by using data from the Taiwan Longitudinal Health Insurance Database 2005. Patients were enrolled on the basis of the International Classification of Diseases, Ninth Revision, Clinical Modification diagnostic codes for DM between January 1, 2004, and December 31, 2007. The prevalence and the adjusted hazard ratios (HRs) of a rotator cuff repair surgery in patients with and without DM were estimated according to the Cox proportional hazard regression analysis using the frailty model. The DM and non-DM cohorts comprised 58,652 patients with DM and 117,304 (1:2) patients without DM after matching for age and sex. The incidence of rotator cuff repair surgery was 41 per 100,000 and 26 per 100,000 person-years in the DM and non-DM cohorts, respectively. The HR of rotator cuff repair surgery during the follow-up period was 1.56 (95% confidence interval [CI] 1.25-1.93, p<0.001) for patients with DM. After adjustment for covariates, the adjusted HR of rotator cuff repair surgery was 1.33 (95% CI, 1.05-1.68, p<0.001) in the DM cohort. DM is an independent risk factor for rotator cuff tear repair surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. [Relationship between status of physical and mental function and quality of life among the elderly people admitted from long-term care insurance].

    PubMed

    Kim, Hyeong Seon; Bae, Nam Kyou; Kwon, In Sun; Cho, Young Chae

    2010-07-01

    This study was performed to determine the levels of quality of life (QOL) according to the grade of long-term care service for the elderly people who were admitted from long-term care insurance, and to reveal its association with the physical and mental functioning such as the Activity of Daily Living (ADL), the Instrumental Activity of Daily Living (IADL), the Center for Epidemiologic Studies Depression Scale (CES-D), and the Mini-Mental State Examination-Korean version (MMSE-K). The interviews were performed during the period from March 1 to May 31, 2009, for 958 elderly people in urban and rural areas. The questionnaire items included various indices such as the ADL, IADL, CES-D, and MMSE-K, as independent variables and the index of QOL, as the dependent ones. For statistical analysis, t-tests were used for the mean scores of QOL according to gender and the grade of long-term care services, and Spearman's correlation was used for each variable. The effects of physical and mental functioning for QOL were assessed by covariance structure analysis. The statistical significance was set at p<0.05. The mean scores of QOL among all the subjects was 55.4 ± 15.62 (Grade I: 49.7 ± 14.17, Grade II: 56.8 ± 14.62, Grade III: 59.4 ± 16.36), and it was lower according to the higher grade of long-term care insurance. In terms of the correlation matrix of the QOL and the physical and mental function factors, the QOL showed positive correlation with the ADL, IADL and MMSE-K, while it had negative correlation with depression. On the analysis of covariance, mental functioning (depression and the MMSE-K) had a greater influence on the level of QOL than the physical functioning (ADL and IADL). The level of the QOL in the elderly people who were admitted from long-term care insurance was lower according to higher the grade of long-term care insurance. Also, the mental functioning (depression and MMSE-K) was more influential on the level of the QOL than the physical functioning (ADL and IADL).

  16. Physical Properties of Normal Grade Biodiesel and Winter Grade Biodiesel

    PubMed Central

    Sadrolhosseini, Amir Reza; Moksin, Mohd Maarof; Nang, Harrison Lau Lik; Norozi, Monir; Yunus, W. Mahmood Mat; Zakaria, Azmi

    2011-01-01

    In this study, optical and thermal properties of normal grade and winter grade palm oil biodiesel were investigated. Surface Plasmon Resonance and Photopyroelectric technique were used to evaluate the samples. The dispersion curve and thermal diffusivity were obtained. Consequently, the variation of refractive index, as a function of wavelength in normal grade biodiesel is faster than winter grade palm oil biodiesel, and the thermal diffusivity of winter grade biodiesel is higher than the thermal diffusivity of normal grade biodiesel. This is attributed to the higher palmitic acid C16:0 content in normal grade than in winter grade palm oil biodiesel. PMID:21731429

  17. Monochromatic Transmittance/Radiance Computations

    DTIC Science & Technology

    1974-12-31

    In the infrared region, these tran- sitions are normally between various vibration -rotation states. There are usually a large number of possible...energy level of the transition, and Q (e,m.) and Q (0,m.) are respectively the ratio of the vibrational and rotational partition function at...values used are listed in Table 2 (Ref. 2). For source conditions, the vibrational partition function cannot be ignored and has been calculated 4

  18. Fault Detection of Rotating Machinery using the Spectral Distribution Function

    NASA Technical Reports Server (NTRS)

    Davis, Sanford S.

    1997-01-01

    The spectral distribution function is introduced to characterize the process leading to faults in rotating machinery. It is shown to be a more robust indicator than conventional power spectral density estimates, but requires only slightly more computational effort. The method is illustrated with examples from seeded gearbox transmission faults and an analytical model of a defective bearing. Procedures are suggested for implementation in realistic environments.

  19. A prospective multipractice investigation of patients with full-thickness rotator cuff tears: the importance of comorbidities, practice, and other covariables on self-assessed shoulder function and health status.

    PubMed

    Harryman, Douglas T; Hettrich, Carolyn M; Smith, Kevin L; Campbell, Barry; Sidles, John A; Matsen, Frederick A

    2003-04-01

    Rotator cuff tears are among the most common conditions of the shoulder. One of the major difficulties in studying patients with rotator cuff tears is that the clinical expression of these tears varies widely and different practices may have substantially different patient populations. The goals of the present prospective multipractice study were to use patient self-assessment questionnaires (1) to identify some of the characteristics of patients with rotator cuff tears, other than the size of the cuff tear, that are correlated with shoulder function, and (2) to determine whether there are significant differences in these characteristics among patients from the practices of different surgeons. Ten surgeons enrolled a total of 333 patients with a full-thickness tear of the supraspinatus tendon into this prospective study. Each patient completed self-assessment questionnaires that included items regarding demographic characteristics, prior treatment, medical and social comorbidities, general health status, and shoulder function. As expected, patients who had an infraspinatus tendon tear as well as a supraspinatus tendon tear had significantly worse ability to use the arm overhead compared with those who had a supraspinatus tear alone (p < 0.005). However, shoulder function and health status were correlated with patient characteristics other than the size of the rotator cuff tear. The number of shoulder functions that were performable was correlated with the subscales of the Short Form-36 and was inversely associated with medical and social comorbidities. The patients from the ten different surgeon practices showed significant differences in almost every parameter, including age, gender, method of tear documentation, tear size, prior treatment, medical and social comorbidities, general health status, and shoulder function. Clinical studies on the natural history of rotator cuff tears and the effectiveness of treatment must control for a wide range of variables, many of which do not pertain directly to the shoulder. Patients from the practices of different surgeons cannot be assumed to be similar with respect to these variables. Patient self-assessment questionnaires appear to offer a practical method of uniform assessment across different practices.

  20. Critical Shoulder Angle and Acromial Index Do Not Influence 24-Month Functional Outcome After Arthroscopic Rotator Cuff Repair.

    PubMed

    Lee, Merrill; Chen, Jerry Yongqian; Liow, Ming Han Lincoln; Chong, Hwei Chi; Chang, Paul; Lie, Denny

    2017-11-01

    Recent studies have shown a correlation between scapular geometry and the development of atraumatic rotator cuff tears. However, a paucity of literature is available on the effects of critical shoulder angle (CSA) and acromial index (AI) on functional outcomes after arthroscopic rotator cuff repair. Hypothesis/Purpose: The purpose was to investigate the influence of CSA and AI on 24-month functional outcomes after arthroscopic rotator cuff repair. The hypothesis was that a larger CSA or AI would result in poorer postoperative outcomes. Cohort study; Level of evidence, 3. The study included 147 patients who underwent arthroscopic double-row rotator cuff repair for radiologically documented full-thickness supraspinatus tears. An independent reviewer measured the CSA and AI on preoperative radiographs. These patients were prospectively enrolled and were evaluated preoperatively as well as at 3, 6, 12, and 24 months postoperatively. Functional outcome was assessed with the Constant Shoulder Score (CSS), Oxford Shoulder Score (OSS), and University of California at Los Angeles (UCLA) Shoulder Rating Scale. The patients were first divided based on CSA: (1) ≤35° (control CSA) and (2) >35° (increased CSA); and then based on AI: (1) ≤0.7 and (2) >0.7. The Student unpaired t test, Pearson chi-square test, and Pearson correlation were performed to examine the influence of CSA and AI on postoperative functional outcome scores. At 6 months of follow-up, the CSS, OSS, and UCLA Shoulder Rating Scale were 10 ± 1, 4 ± 2, and 3 ± 1 points poorer in the increased CSA group compared with the control CSA group ( P = .005, P = .030, and P = .035, respectively). These scores were not significantly different between both AI groups. By 24 months of follow-up, all outcome scores were comparable between both CSA groups as well as between both AI groups. No significant correlation was found between either CSA or AI when compared with CSS, OSS, or UCLA Shoulder Rating Scale at 24 months of follow-up. CSA and AI do not appear to influence 24-month functional outcomes postoperatively and hence are not contraindications to arthroscopic rotator cuff repair.

  1. Predictors of Recoverability of Renal Function after Pyeloplasty in Adults with Ureteropelvic Junction Obstruction.

    PubMed

    Li, Xiao-Dong; Wu, Yu-Peng; Wei, Yong; Chen, Shao-Hao; Zheng, Qing-Shui; Cai, Hai; Xue, Xue-Yi; Xu, Ning

    2018-01-01

    This study aimed to identify factors predicting the recoverability of renal function after pyeloplasty in adult patients with ureteropelvic junction obstruction. We retrospectively reviewed 138 adults with unilateral renal obstruction-induced hydronephrosis and who underwent Anderson-Hynes dismembered pyeloplasty from January 2013 to January 2016. Hydronephrosis was classified preoperatively according to the Society for Fetal Urology (SFU) grading system. All patients underwent Doppler ultrasonography, excretory urography, computed tomography, and technetium-99m-diethylenetriamine pentaacetic acid radioisotope (99mTc DTPA) renography before and after surgery. Renal resistive index (RRI) and 99mTc DTPA renography were repeated at 1, 3, 6, and 12 months. Multivariate analysis identified age, renal pelvic type, SFU grade, preoperative RRI, decline of RRI, and renal parenchyma to hydronephrosis area ratio (PHAR) as independent predictors of renal function recoverability after pyeloplasty. However, preoperative RRI and RRI decline were not significantly associated with recoverability of renal function in patients aged >35 years. Lower preoperative RRI, greater decline in RRI, higher PHAR, lower SFU grade, and extrarenal pelvis were associated with greater improvements in postoperative renal function. Preoperative differential renal function cannot independently predict the recoverability of postoperative renal function in adult patients with unilateral renal obstruction-induced hydronephrosis. SFU grade, renal pelvic type, PHAR, preoperative RRI, and decline in RRI were significantly associated with the recoverability of renal function in adult patients aged <35 years, while only SFU grade, renal pelvic type, and PHAR were significantly associated with renal function recoverability in patients aged ≥35 years. Renal function recovery was better in patients younger than 35 years when compared with older patients. © 2018 S. Karger AG, Basel.

  2. Does the Value of Dynamic Assessment in Predicting End-of-First-Grade Mathematics Performance Differ as a Function of English Language Proficiency?

    ERIC Educational Resources Information Center

    Seethaler, Pamela M.; Fuchs, Lynn S.; Fuchs, Douglas; Compton, Donald L.

    2016-01-01

    The purpose of this study was to assess the added value of dynamic assessment (DA) beyond more conventional static measures for predicting individual differences in year-end 1st-grade calculation (CA) and word-problem (WP) performance, as a function of limited English proficiency (LEP) status. At the start of 1st grade, students (129 LEP; 163…

  3. Can Preoperative Magnetic Resonance Imaging Predict the Reparability of Massive Rotator Cuff Tears?

    PubMed

    Kim, Jung Youn; Park, Ji Seon; Rhee, Yong Girl

    2017-06-01

    Numerous studies have shown preoperative fatty infiltration of rotator cuff muscles to be strongly negatively correlated with the successful repair of massive rotator cuff tears (RCTs). To assess the association between factors identified on preoperative magnetic resonance imaging (MRI), especially infraspinatus fatty infiltration, and the reparability of massive RCTs. Case-control study; Level of evidence, 3. We analyzed a total of 105 patients with massive RCTs for whom MRI was performed ≤6 months before arthroscopic procedures. The mean age of the patients was 62.7 years (range, 46-83 years), and 46 were men. Among them, complete repair was possible in 50 patients (48%) and not possible in 55 patients (52%). The tangent sign, fatty infiltration of the rotator cuff, and Patte classification were evaluated as predictors of reparability. Using the receiver operating characteristic curve and the area under the curve (AUC), the prediction accuracy of each variable and combinations of variables were measured. Reparability was associated with fatty infiltration of the supraspinatus ( P = .0045) and infraspinatus ( P < .001) muscles, the tangent sign ( P = .0033), and the Patte classification ( P < .001) but not with fatty infiltration of the subscapularis and teres minor ( P = .425 and .132, respectively). The cut-off values for supraspinatus and infraspinatus fatty infiltration were grade >3 and grade >2, respectively. The examination of single variables revealed that infraspinatus fatty infiltration showed the highest AUC value (0.812; sensitivity: 0.86; specificity: 0.76), while the tangent sign showed the lowest AUC value (0.626; sensitivity: 0.38; specificity: 0.87). Among 2-variable combinations, the combination of infraspinatus fatty infiltration and the Patte classification showed the highest AUC value (0.874; sensitivity: 0.54; specificity: 0.96). The combination of 4 variables, that is, infraspinatus and supraspinatus fatty infiltration, the tangent sign, and the Patte classification, had an AUC of 0.866 (sensitivity: 0.28; specificity: 0.98), which was lower than the highest AUC value (0.874; sensitivity: 0.54; specificity: 0.96) among the 2-variable combinations. The tangent sign or Patte classification alone was not a predictive indicator of the reparability of massive RCTs. Among single variables, infraspinatus fatty infiltration was the most effective in predicting reparability, while the combination of Goutallier classification <3 of the infraspinatus and Patte classification ≤2 of the rotator cuff muscles was the most predictive among the combinations of variables. This information may help predict the reparability of massive RCTs.

  4. Rotational dynamics and heating of trapped nanovaterite particles (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Arita, Yoshihiko; Richards, Joseph M.; Mazilu, Michael; Spalding, Gabriel C.; Skelton Spesyvtseva, Susan E.; Craig, Derek; Dholakia, Kishan

    2016-09-01

    Rotational control over optically trapped particles has gained significant prominence in recent years. The marriage between light fields possessing optical angular momentum and the material properties of microparticles has been useful to controllably spin particles in liquid, air and vacuum. The rotational degree of freedom adds new functionality to optical traps: in addition to allowing fundamental tests of optical angular momentum, the transfer of spin angular momentum in particular can allow measurements of local viscosity and exert local stresses on cellular systems. We demonstrate optical trapping and controlled rotation of nanovaterite crystals. These particles represent the smallest birefringent crystals ever trapped and set into rotation. Rotation rates of up to 5kHz in water are recorded, representing the fastest rotation to date for dielectric particles in liquid. Laser-induced heating results in the superlinear behaviour of the rotation rate as a function of trap power. We study both the rotational and translational modes of trapped nanovaterite crystals. The particle temperatures derived from those two optomechanical modes are in good agreement, which is supported by a numerical model revealing that the observed heating is dominated by absorption of light by the particles rather than by the surrounding liquid. A comparison is performed with trapped silica particles of similar size. The use of nanovaterite particles open up new studies for levitated optomechanics in vacuum as well as microrheological properties of cells or biological media. Their size and low heating offers prospects of viscosity measurements in ultra-small volumes and potentially simpler uptake by cellular media.

  5. Frequency Response Function Expansion for Unmeasured Translation and Rotation Dofs for Impedance Modelling Applications

    NASA Astrophysics Data System (ADS)

    Avitabile, P.; O'Callahan, J.

    2003-07-01

    Inclusion of rotational effects is critical for the accuracy of the predicted system characteristics, in almost all system modelling studies. However, experimentally derived information for the description of one or more of the components for the system will generally not have any rotational effects included in the description of the component. The lack of rotational effects has long affected the results from any system model development whether using a modal-based approach or an impedance-based approach. Several new expansion processes are described herein for the development of FRFs needed for impedance-based system models. These techniques expand experimentally derived mode shapes, residual modes from the modal parameter estimation process and FRFs directly to allow for the inclusion of the necessary rotational dof. The FRFs involving translational to rotational dofs are developed as well as the rotational to rotational dof. Examples are provided to show the use of these techniques.

  6. Functional Grammar and Teaching of Reading--A Pedagogy Based on Graded Teaching of College English in China

    ERIC Educational Resources Information Center

    Xu, Tuo; Zhang, Beili

    2015-01-01

    This article discusses the importance of functional grammar and demonstrates its application to the teaching of reading among graded college students. Functional grammar holds that a discourse is composed of two levels: the interior level and the exterior level. Therefore, reading activities involve both linguistic elements and contexts.…

  7. Effects of Crossed Brassiere Straps on Pain, Range of Motion, and Electromyographic Activity of Scapular Upward Rotators in Women With Scapular Downward Rotation Syndrome.

    PubMed

    Kang, Min-Hyeok; Choi, Ji-Young; Oh, Jae-seop

    2015-12-01

    Scapular downward rotation syndrome manifests as an abnormally downward-rotated scapula at rest or with arm motion and typically results in neck and shoulder pain. The brassiere strap has been suggested as a possible contributing factor to scapula downward rotation and pain in the upper trapezius because of increased downward rotational force on the lateral aspect of the scapula. No study, however, has examined the influences of a modified brassiere strap on pain in and the function of the scapular muscles. To examine the effects of crossed brassiere straps on the pressure pain threshold (PPT) of the upper trapezius, neck rotation range of motion (ROM), and electromyographic activity of the scapular upward rotators in females with scapular downward rotation syndrome. Cross-over design. Laboratory. In total, 15 female subjects with scapular downward rotation syndrome were recruited at hospitals and a local university. All participants performed neck rotation and humeral elevation under 2 different conditions: parallel and crossed brassiere straps. The PPT of the upper trapezius was measured using an analog algometer, whereas neck rotation ROM was quantified with a 3-dimensional ultrasonic motion analysis system. The electromyographic activities of the upper trapezius, serratus anterior, and lower trapezius during humeral elevation were assessed with a surface electromyography system. Outcome measures were assessed under parallel and crossed brassiere strap conditions, and differences in outcomes between the conditions were analyzed using a paired t-test. The PPT and neck rotation ROM were increased when the subject was wearing the brassiere with crossed versus parallel straps (P < .001). Greater electromyographic activities of the serratus anterior, lower trapezius, and lesser upper trapezius muscles during humeral elevation were found under the crossed strap condition than the parallel strap condition (P < .05). These findings provide useful information for clinicians when designing management programs to decrease pain and improve biomechanical function for females with scapular downward rotation syndrome. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  8. The Impact of Re-tear on the Clinical Outcome after Rotator Cuff Repair Using Open or Arthroscopic Techniques – A Systematic Review

    PubMed Central

    Galanopoulos, Ilias; Ilias, Aslanidis; Karliaftis, Konstantinos; Papadopoulos, Dimitrios; Ashwood, Neil

    2017-01-01

    Background: It is generally accepted that rotator cuff repair gives satisfactory results in the long term, although most studies have so far shown a fairly high rate of structural failure or re-tear. The purpose of this review study is to assess whether failure of the repaired cuff to heal could negatively affect the functional outcome. Methods: This article includes an extensive Internet PubMed based research in the current English-language literature including level I to level V studies as well as systematic reviews. Results: According to this extended study research, the results are mixed; certain reports show that patients with a healed rotator cuff repair have improved function and strength compared to those with structural failure, whereas other studies support the generally perceived concept that tendon re-tear does not lead to inferior clinical outcome. Conclusion: Further high-level prospective studies with larger numbers of patients and longer follow up are needed to overcome the current debate over function between healed and failed rotator cuff repairs. PMID:28400878

  9. Rehabilitation after Rotator Cuff Repair.

    PubMed

    Nikolaidou, Ourania; Migkou, Stefania; Karampalis, Christos

    2017-01-01

    Rotator cuff tears are a very common condition that is often incapacitating. Whether non-surgical or surgical, successful management of rotator cuff disease is dependent on appropriate rehabilitation. If conservative management is insufficient, surgical repair is often indicated. Postsurgical outcomes for patients having had rotator cuff repair can be quite good. A successful outcome is much dependent on surgical technique as it is on rehabilitation. Numerous rehabilitation protocols for the management of rotator cuff disease are based primarily on clinical experience and expert opinion. This article describes the different rehabilitation protocols that aim to protect the repair in the immediate postoperative period, minimize postoperative stiffness and muscle atrophy. A review of currently available literature on rehabilitation after arthroscopic rotator cuff tear repair was performed to illustrate the available evidence behind various postoperative treatment modalities. There were no statistically significant differences between a conservative and an accelerated rehabilitation protocol . Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. The currently available literature did not identify any significant differences in functional outcomes and relative risks of re-tears between delayed and early motion in patients undergoing arthroscopic rotator cuff repairs. A gentle rehabilitation protocol with limits in range of motion and exercise times after arthroscopic rotator cuff repair would be better for tendon healing without taking any substantial risks. A close communication between the surgeon, the patient and the physical therapy team is important and should continue throughout the whole recovery process.

  10. Relationships between eccentric hip isokinetic torque and functional performance.

    PubMed

    Baldon, Rodrigo de Marche; Lobato D, Ferreira Moreira; Carvalho, Lívia Pinheiro; Wun P, Yan Lam; Presotti, Cátia Valéria; Serrão, Fábio Viadanna

    2012-02-01

    Recently, attention in sports has been given to eccentric hip-muscle function, both in preventing musculoskeletal injuries and improving performance. To determine the key isokinetic variables of eccentric hip torque that predict the functional performance of women in the single-leg triple long jump (TLJ) and the timed 6-m single-leg hop (TH). Within-subject correlational study. Musculoskeletal laboratory. 32 healthy women age 18-25 y. The participants performed 2 sets of 5 eccentric hip-abductor/adductor and lateral/medial-rotator isokinetic contractions (30°/s) and 3 attempts in the TLJ and TH. The independent variables were the eccentric hip-abductor and -adductor and medial- and lateral-rotator isokinetic peak torque, normalized according to body mass (Nm/kg). The dependent variables were the longest distance achieved in the TLJ normalized according to body height and the shortest time spent during the execution of the TH. The forward-stepwise-regression analysis showed that the combination of the eccentric hip lateral-rotator and -abductor isokinetic peak torque provided the most efficient estimate of both functional tests, explaining 65% of the TLJ variance (P < .001) and 55% of the TH variance (P < .001). Higher values for eccentric hip lateral-rotator and hip-abductor torques reflected better performance. Thus, the eccentric action of these muscles should be considered in the development of physical training programs that aim to increase functional performance.

  11. Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation

    PubMed Central

    Tchah, Hungwon; Nam, Kiyeun; Yoo, Aeri

    2017-01-01

    AIM To investigate the independent factors associated with photic phenomena in patients implanted with refractive, rotationally asymmetric, multifocal intraocular lenses (MIOLs). METHODS Thirty-four eyes of 34 patients who underwent unilateral cataract surgery, followed by implantation of rotationally asymmetric MIOLs were included. Distance and near visual acuity outcomes, intraocular aberrations, preferred reading distances, preoperative and postoperative refractive errors, mesopic and photopic pupil diameters, and the mesopic and photopic kappa angles were assessed. Patients were also administered a satisfaction survey. Photic phenomena were graded by questionnaire. Independent-related factors were identified by correlation and bivariate logistic regression analyses. RESULTS The distance from the photopic to the mesopic pupil center (pupil center shift) was significantly associated with glare/halo symptoms [odds ratio (OR)=2.065, 95% confidence interval (CI)=0.916-4.679, P=0.006] and night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007). The preoperative photopic angle kappa was significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041). The photopic angle kappa was also significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041) and with night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007) in patients implanted with rotationally asymmetric MIOLs. CONCLUSION A large pupil center shift and misalignment between the visual and pupillary axis (angle kappa) may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs. PMID:28251083

  12. Piezoelectric coupling factor calculations for plates of langatate driven in simple thickness modes by lateral-field-excitation.

    PubMed

    Khan, Ajmal; Ballato, Arthur

    2002-07-01

    Piezoelectric coupling factors for langatate (La3Ga5.5Ta0.5O14) single-crystals driven by lateral-field-excitation have been calculated using the extended Christoffel-Bechmann method. Calculations were made using published materials constants. The results are presented in terms of the lateral piezoelectric coupling factor as functions of in-plane (azimuthal) rotation angle for the three simple thickness vibration modes of some non-rotated, singly-rotated, and doubly-rotated orientations. It is shown that lateral-field-excitation offers the potential to eliminate unwanted vibration modes and to achieve considerably greater piezoelectric coupling versus thickness-field-excitation for the rotated cuts considered and for a doubly-rotated cut that is of potential technological interest.

  13. Teacher-Student Interactions in Fifth Grade Classrooms: Relations with Children's Peer Behavior

    ERIC Educational Resources Information Center

    Luckner, Amy E.; Pianta, Robert C.

    2011-01-01

    This study investigates the extent to which teacher-student interactions in fifth grade classrooms are associated with peer behavior in fifth grade, accounting for prior peer functioning. Participants included 894 fifth grade students from the NICHD Study of Early Child Care and Youth Development. The quality of teacher-student interactions…

  14. LOI/SOHO constraints on oblique rotation of the solar core

    NASA Astrophysics Data System (ADS)

    Gizon, L.; Appourchaux, T.; Gough, D. O.

    The Sun is usually assumed to rotate about a single axis, tilted with respect to the ecliptic normal by an angle of 7.25 degrees. Although we have an excellent knowledge of the direction of the rotation axis of the photospheric layers, we cannot exclude a priori that the direction of the rotation axis could vary as a function of radius. We have tried to check whether the assumption of rotation about a unique axis is consistent with helioseismic data. We report on an attempt to measure the directions of the pulsation axes of several low-degree modes of oscillation in the LOI/SOHO Fourier spectra.

  15. The Unruh effect for eccentric uniformly rotating observers

    NASA Astrophysics Data System (ADS)

    Ramezani-Aval, H.

    It is common to use Galilean rotational transformation (GRT) to investigate the Unruh effect for uniformly rotating observers. However, the rotating observer in this subject is an eccentric observer while GRT is only valid for centrally rotating observers. Thus, the reliability of the results of applying GRT to the study of the Unruh effect might be considered as questionable. In this work, the rotational analog of the Unruh effect is investigated by employing two relativistic rotational transformations corresponding to the eccentric rotating observer, and it is shown that in both cases, the detector response function is nonzero. It is also shown that although consecutive Lorentz transformations cannot give a frame within which the canonical construction can be carried out, the expectation value of particle number operator in canonical approach will be zero if we use modified Franklin transformation. These conclusions reinforce the claim that correspondence between vacuum states defined via canonical field theory and a detector is broken for rotating observers. Some previous conclusions are commented on and some controversies are also discussed.

  16. Factors affecting outcome of triceps motor branch transfer for isolated axillary nerve injury.

    PubMed

    Lee, Joo-Yup; Kircher, Michelle F; Spinner, Robert J; Bishop, Allen T; Shin, Alexander Y

    2012-11-01

    Triceps motor branch transfer has been used in upper brachial plexus injury and is potentially effective for isolated axillary nerve injury in lieu of sural nerve grafting. We evaluated the functional outcome of this procedure and determined factors that influenced the outcome. A retrospective chart review was performed of 21 patients (mean age, 38 y; range, 16-79 y) who underwent triceps motor branch transfer for the treatment of isolated axillary nerve injury. Deltoid muscle strength was evaluated using the modified British Medical Research Council grading at the last follow-up (mean, 21 mo; range, 12-41 mo). The following variables were analyzed to determine whether they affected the outcome of the nerve transfer: the age and sex of the patient, delay from injury to surgery, body mass index (BMI), severity of trauma, and presence of rotator cuff lesions. The Spearman correlation coefficient and multiple linear regression were performed for statistical analysis. The average Medical Research Council grade of deltoid muscle strength was 3.5 ± 1.1. Deltoid muscle strength correlated with the age of the patient, delay from injury to surgery, and BMI of the patient. Five patients failed to achieve more than M3 grade. Among them, 4 patients were older than 50 years and 1 was treated 14 months after injury. In the multiple linear regression model, the delay from injury to surgery, age of the patient, and BMI of the patient were the important factors, in that order, that affected the outcome of this procedure. Isolated axillary nerve injury can be treated successfully with triceps motor branch transfer. However, outstanding outcomes are not universal, with one fourth failing to achieve M3 strength. The outcome of this procedure is affected by the delay from injury to surgery and the age and BMI of the patient. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Recovery of metals from waste printed circuit boards by a mechanical method using a water medium.

    PubMed

    Duan, Chenlong; Wen, Xuefeng; Shi, Changsheng; Zhao, Yuemin; Wen, Baofeng; He, Yaqun

    2009-07-15

    Research on the recycling of waste printed circuit boards (PCB) is at the forefront of environmental pollution prevention and resource recycling. To effectively crush waste PCB and to solve the problem of secondary pollution from fugitive odors and dust created during the crushing process, a wet impacting crusher was employed to achieve comminution liberation of the PCB in a water medium. The function of water in the crushing process was analyzed. When using slippery hammerheads, a rotation speed of 1470 rpm, a water flow of 6m(3)/h and a sieve plate aperture of 2.2mm, 95.87% of the crushed product was sized less than 1mm. 94.30% of the metal was in this grade of product. Using smashed material graded -1mm for further research, a Falcon concentrator was used to recover the metal from the waste PCB. Engineering considerations were the liberation degree, the distribution ratio of the metal and a way to simplify the technology. The separation mechanism for fine particles of different densities in a Falcon concentrator was analyzed in detail and the separation process in the segregation and separation zones was deduced. Also, the magnitude of centrifugal acceleration, the back flow water pressure and the feed slurry concentration, any of which might affect separation results, were studied. A recovery model was established using Design-Expert software. Separating waste PCB, crushed to -1mm, with the Falcon separator gave a concentrated product graded 92.36% metal with a recovery of 97.05%. To do this the reverse water pressure was 0.05 MPa, the speed transducer frequency was set at 30 Hz and the feed density was 20 g/l. A flow diagram illustrating the new technique of wet impact crushing followed by separation with a Falcon concentrator is provided. The technique will prevent environmental pollution from waste PCB and allow the effective recovery of resources. Water was used as the medium throughout the whole process.

  18. Andreas Vesalius' five hundreth anniversary: initiation of the rotator cuff concept.

    PubMed

    Brinkman, Romy J; Hage, J Joris

    2015-12-01

    The rotator cuff concept refers to the four scapulohumeral muscles that stabilize and rotate the humerus relative to the scapula. To date, the first description of the rotator cuff remained unidentified. In light of the 500th birthday of Andreas Vesalius (1515-1564) we searched his 1543 masterwork "Fabrica Corporis Humani Libri Septem" for references to the morphology and function of the rotator cuff muscles. Even though he distinguished three rather than four scapulohumeral muscles, Vesalius recognized the need for structures that prevent dislocation of the shoulder inherent to the morphology of the humeral caput and scapular socket. He recorded "three strong ligaments" and the "three muscles that rotate the arm" of which the tendons completely "embrace the ligaments of the joint" as such structures. Vesalius defined the rotator cuff concept avant la lettre.

  19. A priori mesh grading for the numerical calculation of the head-related transfer functions

    PubMed Central

    Ziegelwanger, Harald; Kreuzer, Wolfgang; Majdak, Piotr

    2017-01-01

    Head-related transfer functions (HRTFs) describe the directional filtering of the incoming sound caused by the morphology of a listener’s head and pinnae. When an accurate model of a listener’s morphology exists, HRTFs can be calculated numerically with the boundary element method (BEM). However, the general recommendation to model the head and pinnae with at least six elements per wavelength renders the BEM as a time-consuming procedure when calculating HRTFs for the full audible frequency range. In this study, a mesh preprocessing algorithm is proposed, viz., a priori mesh grading, which reduces the computational costs in the HRTF calculation process significantly. The mesh grading algorithm deliberately violates the recommendation of at least six elements per wavelength in certain regions of the head and pinnae and varies the size of elements gradually according to an a priori defined grading function. The evaluation of the algorithm involved HRTFs calculated for various geometric objects including meshes of three human listeners and various grading functions. The numerical accuracy and the predicted sound-localization performance of calculated HRTFs were analyzed. A-priori mesh grading appeared to be suitable for the numerical calculation of HRTFs in the full audible frequency range and outperformed uniform meshes in terms of numerical errors, perception based predictions of sound-localization performance, and computational costs. PMID:28239186

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva, F. S.

    Functionally graded components exhibit spatial variations of mechanical properties in contrast with, and as an alternative to, purely homogeneous components. A large class of graded materials, however, are in fact mostly homogeneous materials with property variations (chemical or mechanical) restricted to a specific area or layer produced by applying for example a coating or by introducing sub-surface residual stresses. However, it is also possible to obtain graded materials with a smooth transition of mechanical properties along the entire component, for example in a 40 mm component. This is possible, for example, by using centrifugal casting technique or incremental melting andmore » solidification technique. In this paper we will study fully metallic functionally graded components with a smooth gradient, focusing on fatigue crack propagation. Fatigue propagation will be assessed in the direction parallel to the gradation (in different homogeneous layers of the functionally graded component) to assess what would be fatigue crack propagation on the direction perpendicular to the gradation. Fatigue crack growth rate (standard mode I fatigue crack growth) will be correlated to the mode I stress intensity factor range. Other mechanical properties of different layers of the component (Young's modulus) will also be considered in this analysis. The effect of residual stresses along the component gradation on crack propagation will also be taken into account. A qualitative analysis of the effects of some important features, present in functionally graded materials, will be made based on the obtained results.« less

  1. Suitable Stimuli to Obtain (No) Gender Differences in the Speed of Cognitive Processes Involved in Mental Rotation

    ERIC Educational Resources Information Center

    Jansen-Osmann, Petra; Heil, Martin

    2007-01-01

    Gender differences in speed of perceptual comparison, of picture-plane mental rotation, and in switching costs between trials that do and do not require mental rotation, were investigated as a function of stimulus material with a total sample size of N=360. Alphanumeric characters, PMA symbols, animal drawings, polygons and 3D cube figures were…

  2. Smoother Conversion From Helicopter To Airplane

    NASA Technical Reports Server (NTRS)

    Stroub, Robert H.

    1992-01-01

    Proposed high-speed rotorcraft converts between rotating-wing flight and fixed-wing flight without high vibration. Functions both while hovering and moving at transonic or low supersonic speeds. Aircraft takes off and hovers like ordinary helicopter. After accelerating to sufficient forward speed for conversion, rotor blades retracted into large, rotating hub fairing. Rotation then stopped. Two blades extended to serve as wings, and aircraft accelerates to its cruising speed.

  3. Template based rotation: A method for functional connectivity analysis with a priori templates☆

    PubMed Central

    Schultz, Aaron P.; Chhatwal, Jasmeer P.; Huijbers, Willem; Hedden, Trey; van Dijk, Koene R.A.; McLaren, Donald G.; Ward, Andrew M.; Wigman, Sarah; Sperling, Reisa A.

    2014-01-01

    Functional connectivity magnetic resonance imaging (fcMRI) is a powerful tool for understanding the network level organization of the brain in research settings and is increasingly being used to study large-scale neuronal network degeneration in clinical trial settings. Presently, a variety of techniques, including seed-based correlation analysis and group independent components analysis (with either dual regression or back projection) are commonly employed to compute functional connectivity metrics. In the present report, we introduce template based rotation,1 a novel analytic approach optimized for use with a priori network parcellations, which may be particularly useful in clinical trial settings. Template based rotation was designed to leverage the stable spatial patterns of intrinsic connectivity derived from out-of-sample datasets by mapping data from novel sessions onto the previously defined a priori templates. We first demonstrate the feasibility of using previously defined a priori templates in connectivity analyses, and then compare the performance of template based rotation to seed based and dual regression methods by applying these analytic approaches to an fMRI dataset of normal young and elderly subjects. We observed that template based rotation and dual regression are approximately equivalent in detecting fcMRI differences between young and old subjects, demonstrating similar effect sizes for group differences and similar reliability metrics across 12 cortical networks. Both template based rotation and dual-regression demonstrated larger effect sizes and comparable reliabilities as compared to seed based correlation analysis, though all three methods yielded similar patterns of network differences. When performing inter-network and sub-network connectivity analyses, we observed that template based rotation offered greater flexibility, larger group differences, and more stable connectivity estimates as compared to dual regression and seed based analyses. This flexibility owes to the reduced spatial and temporal orthogonality constraints of template based rotation as compared to dual regression. These results suggest that template based rotation can provide a useful alternative to existing fcMRI analytic methods, particularly in clinical trial settings where predefined outcome measures and conserved network descriptions across groups are at a premium. PMID:25150630

  4. Longitudinal observation of basic mandibular movements: report of a case.

    PubMed

    Hayasaki, H; Okamoto, A; Nakata, S; Yamasaki, Y; Nakata, M

    2003-01-01

    Sound development of mandibular function during childhood is indispensable to establishing healthy function in adults. To examine this developmental process, longitudinal recordings of basic mandibular movements were done using an optoelectronic analysis. Mandibular movements were recorded on five separate occasions in one boy, from an age of six years and five months to 14 years and five months. The incisor pathways during protrusion and lateral excursion were initially shallow, with more anterior than inferior movement, but as he grew the amount of inferior movement and the amount of rotation both increased. Similarly, at his first recording there was very little hinge-like rotation during mouth closing, but rotation increased markedly after eruption of his permanent second molars. These findings suggest that mandibular movements change from being relatively simple with more translation in younger children to more complex movements with more rotation once the permanent dentition is established.

  5. Imaging the dynamics of free-electron Landau states

    PubMed Central

    Schattschneider, P.; Schachinger, Th.; Stöger-Pollach, M.; Löffler, S.; Steiger-Thirsfeld, A.; Bliokh, K. Y.; Nori, Franco

    2014-01-01

    Landau levels and states of electrons in a magnetic field are fundamental quantum entities underlying the quantum Hall and related effects in condensed matter physics. However, the real-space properties and observation of Landau wave functions remain elusive. Here we report the real-space observation of Landau states and the internal rotational dynamics of free electrons. States with different quantum numbers are produced using nanometre-sized electron vortex beams, with a radius chosen to match the waist of the Landau states, in a quasi-uniform magnetic field. Scanning the beams along the propagation direction, we reconstruct the rotational dynamics of the Landau wave functions with angular frequency ~100 GHz. We observe that Landau modes with different azimuthal quantum numbers belong to three classes, which are characterized by rotations with zero, Larmor and cyclotron frequencies, respectively. This is in sharp contrast to the uniform cyclotron rotation of classical electrons, and in perfect agreement with recent theoretical predictions. PMID:25105563

  6. A surface-bound molecule that undergoes optically biased Brownian rotation.

    PubMed

    Hutchison, James A; Uji-i, Hiroshi; Deres, Ania; Vosch, Tom; Rocha, Susana; Müller, Sibylle; Bastian, Andreas A; Enderlein, Jörg; Nourouzi, Hassan; Li, Chen; Herrmann, Andreas; Müllen, Klaus; De Schryver, Frans; Hofkens, Johan

    2014-02-01

    Developing molecular systems with functions analogous to those of macroscopic machine components, such as rotors, gyroscopes and valves, is a long-standing goal of nanotechnology. However, macroscopic analogies go only so far in predicting function in nanoscale environments, where friction dominates over inertia. In some instances, ratchet mechanisms have been used to bias the ever-present random, thermally driven (Brownian) motion and drive molecular diffusion in desired directions. Here, we visualize the motions of surface-bound molecular rotors using defocused fluorescence imaging, and observe the transition from hindered to free Brownian rotation by tuning medium viscosity. We show that the otherwise random rotations can be biased by the polarization of the excitation light field, even though the associated optical torque is insufficient to overcome thermal fluctuations. The biased rotation is attributed instead to a fluctuating-friction mechanism in which photoexcitation of the rotor strongly inhibits its diffusion rate.

  7. [Design and Analysis of CT High-speed Data Transmission Rotating Connector Ring System Retaining Ring].

    PubMed

    Pan, Li; Cao, Jujiang; Liu, Min; Fu, Weiwei

    2017-11-30

    High speed data transmission rotating connector system for signal high-speed transmission used in the fixed end and rotating end, it is one of the core component in the CT system. This paper involves structure design and analysis of the retaining ring in the CT high speed data transmission rotating connector system based on the principle of off-axis free space optical transmission. According to the problem of the actual engineering application of space limitations, optical fiber fixed and collimator installation location, we designed the structure of the retaining ring. Using the static analysis function of ANSYS Workbench, it verifies rationality and safety of the strength of retaining ring structure. And based on modal analysis function of ANSYS Workbench, it evaluates the effect of the retaining ring on the stability of the system date transmission, and provides theoretical basis for the feasibility of the structure in practical application.

  8. Anomalous scaling of passive scalars in rotating flows.

    PubMed

    Rodriguez Imazio, P; Mininni, P D

    2011-06-01

    We present results of direct numerical simulations of passive scalar advection and diffusion in turbulent rotating flows. Scaling laws and the development of anisotropy are studied in spectral space, and in real space using an axisymmetric decomposition of velocity and passive scalar structure functions. The passive scalar is more anisotropic than the velocity field, and its power spectrum follows a spectral law consistent with ~ k[Please see text](-3/2). This scaling is explained with phenomenological arguments that consider the effect of rotation. Intermittency is characterized using scaling exponents and probability density functions of velocity and passive scalar increments. In the presence of rotation, intermittency in the velocity field decreases more noticeably than in the passive scalar. The scaling exponents show good agreement with Kraichnan's prediction for passive scalar intermittency in two dimensions, after correcting for the observed scaling of the second-order exponent.

  9. A longitudinal study of visual function in carriers of X-linked recessive retinitis pigmentosa.

    PubMed

    Grover, S; Fishman, G A; Anderson, R J; Lindeman, M

    2000-02-01

    This study was carried out to evaluate the progression of visual function impairment in carriers of X-linked recessive retinitis pigmentosa. We also assessed the relationship between the retinal findings at presentation and the extent of deterioration. Observational, retrospective, case series. Twenty-seven carriers of X-linked recessive retinitis pigmentosa. Each carrier was clinically categorized into one of four grades (grades 0 through 3) depending on the presence or absence of a tapetal-like retinal reflex and the extent of peripheral pigmentary degeneration. A complete ophthalmologic examination was performed and data for visual acuity, visual field area, and electroretinographic measurements were collected on the most recent visit in both eyes. These were then compared with similar data obtained on their initial visits. A comparison of visual function was carried out between the initial visit and the most recent visit on each carrier. The visual acuity was measured with Snellen's acuity charts. The visual fields to targets V-4-e and II-4-e were planimeterized and used for the analysis. The electroretinographic (ERG) measures used were light-adapted single-flash b-wave amplitudes and 30-Hz red flicker for cone function, dark-adapted maximal b-wave amplitudes, and response to a low intensity blue-flash for rod function. None of the 11 carriers with a tapetal-like reflex only (grade 1) showed any significant change in visual acuity or fields as compared with 3 of 7 (43%) carriers with diffuse peripheral pigmentary findings (grade 3) who showed significant deterioration in visual acuity in at least one eye, and 6 of 7 (86%) who showed a significant decrease in visual field area with at least one target size in at least one eye. By comparison, only 1 of 10 carriers with a grade 1 fundus finding demonstrated a significant decrease in maximal dark-adapted ERG function as compared with 5 of 6 (83%) carriers with grade 3 in response to a single-flash stimulus and with 4 of 5 (80%) carriers in response to a single-flash blue stimulus. For the single-flash photopic response, none of the 10 carriers with grade 1 showed any significant deterioration, whereas 2 of 4 (50%) with grade 3 did show such deterioration. The ERG responses for carriers with grade 2 were in between the extent of decrease in ERG amplitudes of those in carriers with grades 1 and 3. In our cohort of X-linked retinitis pigmentosa carriers, those with only a tapetal-like retinal reflex at presentation had a better prognosis to retain visual function than those with peripheral retinal pigmentation. These data are useful in counseling such carriers as to their visual prognosis.

  10. Retaining a Resilient and Enduring Workforce: Examination of Duty/Position Rotational Assignments for Civilian Acquisition Positions

    DTIC Science & Technology

    2015-04-12

    the Defense Acquisition Workforce becomes increasingly volatile due to reduced resources, an aging workforce, limitations imposed by the BCA, and...development frameworks is visualized in Figures 3 through 6. “[S]enior leaders in the military are expected to yield a ‘ rich array of career...selectively at mid-grade ranks, so that a base of deep understanding is built before these leaders become senior in position and are expected to shape and

  11. Improved apparatus for predictive diagnosis of rotator cuff disease

    NASA Astrophysics Data System (ADS)

    Pillai, Anup; Hall, Brittany N.; Thigpen, Charles A.; Kwartowitz, David M.

    2014-03-01

    Rotator cuff disease impacts over 50% of the population over 60, with reports of incidence being as high as 90% within this population, causing pain and possible loss of function. The rotator cuff is composed of muscles and tendons that work in tandem to support the shoulder. Heavy use of these muscles can lead to rotator cuff tear, with the most common causes is age-related degeneration or sport injuries, both being a function of overuse. Tears ranges in severity from partial thickness tear to total rupture. Diagnostic techniques are based on physical assessment, detailed patient history, and medical imaging; primarily X-ray, MRI and ultrasonography are the chosen modalities for assessment. The final treatment technique and imaging modality; however, is chosen by the clinician is at their discretion. Ultrasound has been shown to have good accuracy for identification and measurement of full-thickness and partial-thickness rotator cuff tears. In this study, we report on the progress and improvement of our method of transduction and analysis of in situ measurement of rotator cuff biomechanics. We have improved the ability of the clinician to apply a uniform force to the underlying musculotendentious tissues while simultaneously obtaining the ultrasound image. This measurement protocol combined with region of interest (ROI) based image processing will help in developing a predictive diagnostic model for treatment of rotator cuff disease and help the clinicians choose the best treatment technique.

  12. Photomechanical Deformation of Azobenzene-Functionalized Polyimides Synthesized with Bulky Substituents (Postprint)

    DTIC Science & Technology

    2017-12-06

    mechanical response of the azobenzene- functionalized polyimide is correlated to the rotational freedom of the polyimide chains (resulting in extensive... correlated to the rotational freedom of the polyimide chains (resulting in extensive segmental mobility) and fractional free volume (FFV > 0.1...response has been described,34 and a recent simulation study on the stress relaxation dynamics of azo-polyimides has provided insights into the correlation

  13. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  14. Active vibration control of functionally graded beams with piezoelectric layers based on higher order shear deformation theory

    NASA Astrophysics Data System (ADS)

    Bendine, K.; Boukhoulda, F. B.; Nouari, M.; Satla, Z.

    2016-12-01

    This paper reports on a study of active vibration control of functionally graded beams with upper and lower surface-bonded piezoelectric layers. The model is based on higher-order shear deformation theory and implemented using the finite element method (FEM). The proprieties of the functionally graded beam (FGB) are graded along the thickness direction. The piezoelectric actuator provides a damping effect on the FGB by means of a velocity feedback control algorithm. A Matlab program has been developed for the FGB model and compared with ANSYS APDL. Using Newmark's method numerical solutions are obtained for the dynamic equations of FGB with piezoelectric layers. Numerical results show the effects of the constituent volume fraction and the influence the feedback control gain on the frequency and dynamic response of FGBs.

  15. Kinetic magnetic resonance imaging analysis of abnormal segmental motion of the functional spine unit.

    PubMed

    Kong, Min Ho; Hymanson, Henry J; Song, Kwan Young; Chin, Dong Kyu; Cho, Yong Eun; Yoon, Do Heum; Wang, Jeffrey C

    2009-04-01

    The authors conducted a retrospective observational study using kinetic MR imaging to investigate the relationship between instability, abnormal sagittal segmental motion, and radiographic variables consisting of intervertebral disc degeneration, facet joint osteoarthritis (FJO), degeneration of the interspinous ligaments, ligamentum flavum hypertrophy (LFH), and the status of the paraspinal muscles. Abnormal segmental motion, defined as > 10 degrees angulation and > 3 mm of translation in the sagittal plane, was investigated in 1575 functional spine units (315 patients) in flexion, neutral, and extension postures using kinetic MR imaging. Each segment was assessed based on the extent of disc degeneration (Grades I-V), FJO (Grades 1-4), interspinous ligament degeneration (Grades 1-4), presence of LFH, and paraspinal muscle fatty infiltration observed on kinetic MR imaging. These factors are often noted in patients with degenerative disease, and there are grading systems to describe these changes. For the first time, the authors attempted to address the relationship between these radiographic observations and the effects on the motion and instability of the functional spine unit. The prevalence of abnormal translational motion was significantly higher in patients with Grade IV degenerative discs and Grade 3 arthritic facet joints (p < 0.05). In patients with advanced disc degeneration and FJO, there was a lesser amount of motion in both segmental translation and angulation when compared with lower grades of degeneration, and this difference was statistically significant for angular motion (p < 0.05). Patients with advanced degenerative Grade 4 facet joint arthritis had a significantly lower percentage of abnormal angular motion compared to patients with normal facet joints (p < 0.001). The presence of LFH was strongly associated with abnormal translational and angular motion. Grade 4 interspinous ligament degeneration and the presence of paraspinal muscle fatty infiltration were both significantly associated with excessive abnormal angular motion (p < 0.05). This kinetic MR imaging analysis showed that the lumbar functional unit with more disc degeneration, FJO, and LFH had abnormal sagittal plane translation and angulation. These findings suggest that abnormal segmental motion noted on kinetic MR images is closely associated with disc degeneration, FJO, and the pathological characteristics of interspinous ligaments, ligamentum flavum, and paraspinal muscles. Kinetic MR imaging in patients with mechanical back pain may prove a valuable source of information about the stability of the functional spine unit by measuring abnormal segmental motion and grading of radiographic parameters simultaneously.

  16. An Analysis of Grade 11 Learners' Levels of Understanding of Functions in Terms of APOS Theory

    ERIC Educational Resources Information Center

    Chimhande, Tinoda; Naidoo, Ana; Stols, Gerrit

    2017-01-01

    This article reports on a study of six Grade 11 learners' levels of understanding of concepts related to the function definition and representation. Task-based clinical interviews were used to elicit the learners' interpretations and reasoning when working with these function-related concepts. Indicators for Action-Process-Object-Schema (APOS)…

  17. A Preliminary Study of Bully and Victim Behavior in Old-for-Grade Students: Another Potential Hidden Cost of Grade Retention or Delayed School Entry

    ERIC Educational Resources Information Center

    Crothers, Laura M.; Schreiber, James B.; Schmitt, Ara J.; Bell, G. Ronald; Blasik, Jessica; Comstock, Leigh A.; Greisler, Michael J.; Keener, Dana; King, Jamie M.; Lipinski, John

    2010-01-01

    Mounting evidence suggests that being an old-for-grade student, as a result of grade retention or delayed school entry, is related to negative outcomes across various domains of functioning. No known study has examined the relations between old-for-grade status and specific childhood/adolescent bully and victim behaviors. The first purpose of this…

  18. Assessment of Thermal Performance of Functionally Graded Materials in Longitudinal Fins

    NASA Astrophysics Data System (ADS)

    Hassanzadeh, R.; Bilgili, M.

    2018-01-01

    Assessment of the thermal characteristics of materials in heat exchangers with longitudinal fins is performed in the case where a conventional homogeneous material of a longitudinal fin is replaced by a functionally graded one, in which the fin material properties, such as the conductivity, are assumed to be graded as linear and power-law functions along the normal axis from the fin base to the fin tip. The resulting equations are calculated under two (Dirichlet and Neumann) boundary conditions. The equations are solved by an approximate analytical method with the use of the mean value theorem. The results show that the inhomogeneity index of a functionally graded material plays an important role for the thermal energy characteristics in such heat exchangers. In addition, it is observed that the use of such a material in longitudinal fins enhances the rate of heat transfer between the fin surface and surrounding fluid. Hopefully, the results obtained in the study will arouse interest of designers in heat exchange industry.

  19. Numerical study of the radiometric phenomenon exhibited by a rotating Crookes radiometer

    NASA Astrophysics Data System (ADS)

    Anikin, Yu. A.

    2011-11-01

    The two-dimensional rarefied gas flow around a rotating Crookes radiometer and the arising radiometric forces are studied by numerically solving the Boltzmann kinetic equation. The computations are performed in a noninertial frame of reference rotating together with the radiometer. The collision integral is directly evaluated using a projection method, while second- and third-order accurate TVD schemes are used to solve the advection equation and the equation for inertia-induced transport in the velocity space, respectively. The radiometric forces are found as functions of the rotation frequency.

  20. Rotational-vibrational coupling in the theory of electron-molecule scattering

    NASA Technical Reports Server (NTRS)

    Temkin, A.; Sullivan, E. C.

    1974-01-01

    The adiabatic-nuclei approximation of vibrational-rotational excitation of homonuclear diatomic molecules can be simply augmented to describe the vibrational-rotational coupling by including the dependence of the vibrational wave function on j. Appropriate formulas are given, and the theory, is applied to e-H2 excitation, whereby it is shown that deviations from the simple Born-Oppenheimer approximation measured by Wong and Schultz can be explained. More important, it can be seen that the inclusion of the j-dependent centrifugal term is essential for transitions involving high-rotational quantum numbers.

  1. Basic principles and recent observations of rotationally sampled wind

    NASA Technical Reports Server (NTRS)

    Connell, James R.

    1995-01-01

    The concept of rotationally sampled wind speed is described. The unusual wind characteristics that result from rotationally sampling the wind are shown first for early measurements made using an 8-point ring of anemometers on a vertical plane array of meteorological towers. Quantitative characterization of the rotationally sampled wind is made in terms of the power spectral density function of the wind speed. Verification of the importance of the new concept is demonstrated with spectral analyses of the response of the MOD-OA blade flapwise root bending moment and the corresponding rotational analysis of the wind measured immediately upwind of the MOD-OA using a 12-point ring of anemometers on a 7-tower vertical plane array. The Pacific Northwest Laboratory (PNL) theory of the rotationally sampled wind speed power spectral density function is tested successfully against the wind spectrum measured at the MOD-OA vertical plane array. A single-tower empirical model of the rotationally sampled wind speed is also successfully tested against the measurements from the full vertical plane array. Rotational measurements of the wind velocity with hotfilm anemometers attached to rotating blades are shown to be accurate and practical for research on winds at the blades of wind turbines. Some measurements at the rotor blade of a MOD-2 turbine using the hotfilm technique in a pilot research program are shown. They are compared and contrasted to the expectations based upon application of the PNL theory of rotationally sampled wind to the MOD-2 size and rotation rate but without teeter, blade bending, or rotor induction accounted for. Finally, the importance of temperature layering and of wind modifications due to flow over complex terrain is demonstrated by the use of hotfilm anemometer data, and meteorological tower and acoustic doppler sounder data from the MOD-2 site at Goodnoe Hills, Washington.

  2. Postoperative stiff shoulder after open rotator cuff repair: a 3- to 20-year follow-up study.

    PubMed

    Vastamäki, H; Vastamäki, M

    2014-12-01

    Stiffness after a rotator cuff tear is common. So is stiffness after an arthroscopic rotator cuff repair. In the literature, however, postoperative restriction of passive range of motion after open rotator cuff repair in shoulders with free passive range of motion at surgery has seldom been recognized. We hypothesize that this postoperative stiffness is more frequent than recognized and slows the primary postoperative healing after a rotator cuff reconstruction. We wondered how common is postoperative restriction of both active and passive range of motion after open rotator cuff repair in shoulders with free passive preoperative range of motion, how it recovers, and whether this condition influences short- and long-term results of surgery. We also explored factors predicting postoperative shoulder stiffness. We retrospectively identified 103 postoperative stiff shoulders among 416 consecutive open rotator cuff repairs, evaluating incidence and duration of stiffness, short-term clinical results and long-term range of motion, pain relief, shoulder strength, and functional results 3-20 (mean 8.7) years after surgery in 56 patients. The incidence of postoperative shoulder stiffness was 20%. It delayed primary postoperative healing by 3-6 months and resolved during a mean 6.3 months postoperatively. External rotation resolved first, corresponding to that of the controls at 3 months; flexion and abduction took less than 1 year after surgery. The mean summarized range of motion (flexion + abduction + external rotation) increased as high as 93% of the controls' range of motion by 6 months and 100% by 1 year. Flexion, abduction, and internal rotation improved to the level of the contralateral shoulders as did pain, strength, and function. Age at surgery and condition of the biceps tendon were related to postoperative stiffness. Postoperative stiff shoulder after open rotator cuff repair is a common complication resolving in 6-12 months with good long-term results. © The Finnish Surgical Society 2013.

  3. Design, Manufacturing and Characterization of Functionally Graded Flextensional Piezoelectric Actuators

    NASA Astrophysics Data System (ADS)

    Amigo, R. C. R.; Vatanabe, S. L.; Silva, E. C. N.

    2013-03-01

    Previous works have been shown several advantages in using Functionally Graded Materials (FGMs) for the performance of flextensional devices, such as reduction of stress concentrations and gains in reliability. In this work, the FGM concept is explored in the design of graded devices by using the Topology Optimization Method (TOM), in order to determine optimal topologies and gradations of the coupled structures of piezoactuators. The graded pieces are manufactured by using the Spark Plasma Sintering (SPS) technique and are bonded to piezoelectric ceramics. The graded actuators are then tested by using a modular vibrometer system for measuring output displacements, in order to validate the numerical simulations. The technological path developed here represents the initial step toward the manufacturing of an integral piezoelectric device, constituted by piezoelectric and non-piezoelectric materials without bonding layers.

  4. Parental Autonomy Granting and School Functioning among Chinese Adolescents: The Moderating Role of Adolescents' Cultural Values.

    PubMed

    Wang, Cixin; Do, Kieu Anh; Bao, Leiping; Xia, Yan R; Wu, Chaorong

    2017-01-01

    School adjustment and achievement are important indicators of adolescents' well-being; however, few studies have examined the risk and protective factors predicting students' school adjustment and achievement at the individual, familial, and cultural level. The present study examined the influences of individual and familial factors and cultural values on Chinese adolescents' school functioning (e.g., school adjustment and grades). It also tested whether cultural values moderated the relationship between parenting and adolescents' school functioning. Self-report data were collected from a stratified random sample of 2,864 adolescents (51.5% female, mean age = 15.52 years, grade 6th - 12th) from 55 classrooms, in 13 schools in Shanghai, China. Results showed that self-esteem ( b se→adj = 0.05, SE = 0.01, p < 0.001; b se→grades = 0.08, SE = 0.02, p < 0.001), parent-adolescent conflict ( b conflict→adj = -0.03, SE = 0.00, p < 0.001; b conflict→grades = -0.04, SE = 0.01, p < 0.001), and conformity to parental expectations ( b conform→adj = -0.03, SE = 0.02, p < 0.05; b conform→grades = 0.10, SE = 0.04, p < 0.05) all had significant effects on both school adjustment and grades, respectively. More importantly, results showed that independent self-construal moderated the relationship between parental autonomy granting and adolescents' grades ( b indepxautom = 0.06, SE = 0.02, p < 0.01). The findings suggest that cultural values may influence adolescents' appraisal of parental autonomy granting, which then impacts their school functioning.

  5. Supination and Pronation Strength Deficits Persist at 2-4 Years after Treatment of Distal Radius Fractures.

    PubMed

    Ploegmakers, Joris; The, Bertram; Wang, Allan; Brutty, Mike; Ackland, Tim

    2015-10-01

    Forearm rotation is a key function in the upper extremity. Following distal radius fracture, residual disability may occur in tasks requiring forearm rotation. The objectives of this study are to define pronation and supination strength profiles tested through the range of forearm rotation in normal individuals, and to evaluate the rotational strength profiles and rotational strength deficits across the testing range in a cohort of patients treated for distal radius fracture associated with an ulnar styloid base fracture. In a normative cohort of 29 subjects the supination strength profile showed an increasing linear relationship from supination to pronation. Twelve subjects were evaluated 2-4 years after anatomical open reduction and volar plate fixation of a distal radius fracture. The injured wrist was consistently weaker (corrected for hand dominance) in both supination and pronation strength in all testing positions, with the greatest loss in 60 degrees supination. Mean supination strength loss across all testing positions was significantly correlated with worse PRWE scores, highlighting the importance of supination in wrist function.

  6. The evolutionary origin of jaw yaw in mammals

    PubMed Central

    Grossnickle, David M.

    2017-01-01

    Theria comprises all but three living mammalian genera and is one of the most ecologically pervasive clades on Earth. Yet, the origin and early history of therians and their close relatives (i.e., cladotherians) remains surprisingly enigmatic. A critical biological function that can be compared among early mammal groups is mastication. Morphometrics and modeling analyses of the jaws of Mesozoic mammals indicate that cladotherians evolved musculoskeletal anatomies that increase mechanical advantage during jaw rotation around a dorsoventrally-oriented axis (i.e., yaw) while decreasing the mechanical advantage of jaw rotation around a mediolaterally-oriented axis (i.e., pitch). These changes parallel molar transformations in early cladotherians that indicate their chewing cycles included significant transverse movement, likely produced via yaw rotation. Thus, I hypothesize that cladotherian molar morphologies and musculoskeletal jaw anatomies evolved concurrently with increased yaw rotation of the jaw during chewing cycles. The increased transverse movement resulting from yaw rotation may have been a crucial evolutionary prerequisite for the functionally versatile tribosphenic molar morphology, which underlies the molars of all therians and is retained by many extant clades. PMID:28322334

  7. Vibration and buckling of rotating, pretwisted, preconed beams including Coriolis effects

    NASA Technical Reports Server (NTRS)

    Subrahmanyam, K. B.; Kaza, K. R. V.

    1985-01-01

    The effects of pretwist, precone, setting angle and Coriolis forces on the vibration and buckling behavior of rotating, torsionally rigid, cantilevered beams were studied. The beam is considered to be clamped on the axis of rotation in one case, and off the axis of rotation in the other. Two methods are employed for the solution of the vibration problem: (1) one based upon a finite-difference approach using second order central differences for solution of the equations of motion, and (2) based upon the minimum of the total potential energy functional with a Ritz type of solution procedure making use of complex forms of shape functions for the dependent variables. The individual and collective effects of pretwist, precone, setting angle, thickness ratio and Coriolis forces on the natural frequencies and the buckling boundaries are presented. It is shown that the inclusion of Coriolis effects is necessary for blades of moderate to large thickness ratios while these effects are not so important for small thickness ratio blades. The possibility of buckling due to centrifugal softening terms for large values of precone and rotation is shown.

  8. Vibration and buckling of rotating, pretwisted, preconed beams including Cooriolis effects

    NASA Technical Reports Server (NTRS)

    Subrahmanyam, K. B.; Kaza, K. R. V.

    1985-01-01

    The effects of pretwist, precone, setting angle and Coriolis forces on the vibration and buckling behavior of rotating, torsionally rigid, cantilevered beams were studied. The beam is considered to be clamped on the axis of rotation in one case, and off the axis of rotation in the other. Two methods are employed for the solution of the vibration problem: (1) one based upon a finite-difference approach using second order central differences for solution of the equations of motion, and (2) based upon the minimum of the total potential energy functional with a Ritz type of solution procedure making use of complex forms of shape functions for the dependent variables. The individual and collective effects of pretwist, precone, setting angle, thickness ratio and Coriolis forces on the natural frequencies and the buckling boundaries are presented. It is shown that the inclusion of Coriolis effects is necessary for blades of moderate to large thickness ratios while these effects are not so important for small thickness ratio blades. The possibility of buckling due to centrifugal softening terms for large values of precone and rotation is shown.

  9. Relation between perception of vertical axis rotation and vestibulo-ocular reflex symmetry

    NASA Technical Reports Server (NTRS)

    Peterka, Robert J.; Benolken, Martha S.

    1991-01-01

    Subjects seated in a vertical axis rotation chair controlled their rotational velocity by adjusting a potentiometer. Their goal was to null out pseudorandom rotational perturbations in order to remain perceptually stationary. Most subjects showed a slow linear drift of velocity (a constant acceleration) to one side when they were deprived of an earth-fixed visual reference. The amplitude and direction of this drift can be considered a measure of a static bias in the subject's perception of rotation. The presence of a perceptual bias is consistent with a small, constant imbalance of vestibular function which could be of either central or peripheral origin. Deviations from perfect vestibulocular reflex (VOR) symmetry are also assumed to be related to imbalances in either peripheral or central vestibular function. Researchers looked for correlations between perceptual bias and various measures of vestibular reflex symmetry that might suggest a common source for both reflective and perceptual imbalances. No correlations were found. Measurement errors could not account for these results since repeated tests on the same subjects of both perceptual bias and VOR symmetry were well correlated.

  10. Single-Versus Double-Row Arthroscopic Rotator Cuff Repair in Massive Tears

    PubMed Central

    Wang, EnZhi; Wang, Liang; Gao, Peng; Li, ZhongJi; Zhou, Xiao; Wang, SongGang

    2015-01-01

    Background It is a challenge for orthopaedic surgeons to treat massive rotator cuff tears. The optimal management of massive rotator cuff tears remains controversial. Therefore, the goal of this study was to compare arthroscopic single- versus double-row rotator cuff repair with a larger sample size. Material/Methods Of the subjects with massive rotator cuff tears, 146 were treated using single-row repair, and 102 were treated using double-row repair. Pre- and postoperative functional outcomes and radiographic images were collected. The clinical outcomes were evaluated for a minimum of 2 years. Results No significant differences were shown between the groups in terms of functional outcomes. Regarding the integrity of the tendon, a lower rate of post-treatment retear was observed in patients who underwent double-row repair compared with single-row repair. Conclusions The results suggest that double-row repair is relatively superior in shoulder ROM and the strength of tendon compared with single-row repair. Future studies involving more patients in better-designed randomized controlled trials will be required. PMID:26017641

  11. The research of the coupled orbital-attitude controlled motion of celestial body in the neighborhood of the collinear libration point L1

    NASA Astrophysics Data System (ADS)

    Shmyrov, A.; Shmyrov, V.; Shymanchuk, D.

    2017-10-01

    This article considers the motion of a celestial body within the restricted three-body problem of the Sun-Earth system. The equations of controlled coupled attitude-orbit motion in the neighborhood of collinear libration point L1 are investigated. The translational orbital motion of a celestial body is described using Hill's equations of circular restricted three-body problem of the Sun-Earth system. Rotational orbital motion is described using Euler's dynamic equations and quaternion kinematic equation. We investigate the problem of stability of celestial body rotational orbital motion in relative equilibrium positions and stabilization of celestial body rotational orbital motion with proposed control laws in the neighborhood of collinear libration point L1. To study stabilization problem, Lyapunov function is constructed in the form of the sum of the kinetic energy and special "kinematic function" of the Rodriguez-Hamiltonian parameters. Numerical modeling of the controlled rotational motion of a celestial body at libration point L1 is carried out. The numerical characteristics of the control parameters and rotational motion are given.

  12. Effects of Faraday Rotation Observed in Filter Magnetograph Data

    NASA Technical Reports Server (NTRS)

    Hagyard, Mona J.; Adams, Mitzi L.; Smith, J. E.; West, Edward A.

    1999-01-01

    In this paper we analyze the effects of Faraday rotation on the azimuth of the transverse magnetic field from observations taken with the Marshall Space Flight Center's vector magnetograph for a simple sunspot observed on June 9, 1985. Vector magnetograms were obtained over the wavelength interval of 170 mA redward of line center of the Fe I 5250.22 A spectral line to 170 mA to the blue, in steps of 10 mA. These data were analyzed to produce the variation of the azimuth as a function of wavelength at each pixel over the field of vi ew of the sunspot. At selected locations in the sunspot, curves of the observed variation of azimuth with wavelength were compared with model calculations for the amount of Faraday rotation of the azimuth. From these comparisons we derived the amount of rotation as functions of bo th the magnitude and inclination of the sunspot's field and deduced the ranges of these field values for which Faraday rotation presents a significant problem in observations taken near the center of a spectral line.

  13. Cytotoxicity of Protein-Carbon Nanotubes on J774 Macrophages Is a Functionalization Grade-Dependent Effect

    PubMed Central

    Montes-Fonseca, Silvia Lorena; Sánchez-Ramírez, Blanca; Luna-Velasco, Antonia; Arzate-Quintana, Carlos; Silva-Cazares, Macrina Beatriz; González Horta, Carmen

    2015-01-01

    Carbon nanotubes (CNTs) are used as carriers in medicine due to their ability to be functionalized with chemical substances. However, cytotoxicity analysis is required prior to use for in vivo models. The aim of this study was to evaluate the cytotoxic effect of CNTs functionalized with a 46 kDa surface protein from Entamoeba histolytica (P46-CNTs) on J774A macrophages. With this purpose, CNTs were synthesized by spray pyrolysis and purified (P-CNTs) using sonication for 48 h. A 46 kDa protein, with a 4.6–5.4 pI range, was isolated from E. histolytica HM1:IMSS strain trophozoites using an OFFGEL system. The P-CNTs were functionalized with the purified 46 kDa protein, classified according to their degree of functionalization, and characterized by Raman and Infrared spectroscopy. In vitro cytotoxicity was evaluated by MTT, apoptosis, and morphological assays. The results demonstrated that P46-CNTs exhibited cytotoxicity dependent upon the functionalized grade. Contrary to what was expected, P46-CNTs with a high grade of functionalization were more toxic to J774 macrophages than P46-CNTs with a low grade of functionalization, than P-CNTs, and had a similar level of toxicity as UP-CNT. This suggests that the nature of the functionalized protein plays a key role in the cytotoxicity of these nanoparticles. PMID:26075262

  14. Modal testing of a rotating wind turbine

    NASA Astrophysics Data System (ADS)

    Carne, T. G.; Nord, A. R.

    1982-11-01

    A testing technique was developed to measure the modes of vibration of a rotating vertical-axis wind turbine. This technique was applied to the Sandia Two-Meter Turbine, where the changes in individual modal frequencies as a function of the rotational speed were tracked from 0 rpm (parked) to 600 rpm. During rotational testing, the structural response was measured using a combination of strain gages and accelerometers, passing the signals through slip rings. Excitation of the turbine structure was provided by a scheme which suddenly released a pretensioned cable, thus plucking the turbine as it was rotating at a set speed. In addition to calculating the real modes of the parked turbine, the modes of the rotating turbine were also determined at several rotational speeds. The modes of the rotating system proved to be complex due to centrifugal and Coriolis effects. The modal data for the parked turbine were used to update a finite-element model. Also, the measured modal parameters for the rotating turbine were compared to the analytical results, thus verifying the analytical procedures used to incorporate the effects of the rotating coordinate system.

  15. Establishing a New Screening System for Mild Cognitive Impairment and Alzheimer's Disease with Mental Rotation Tasks that Evaluate Visuospatial Function.

    PubMed

    Suzuki, Ayuko; Shinozaki, Jun; Yazawa, Shogo; Ueki, Yoshino; Matsukawa, Noriyuki; Shimohama, Shun; Nagamine, Takashi

    2018-01-01

    The mental rotation task is well-known for the assessment of visuospatial function; however, it has not been used for screening of dementia patients. The aim of this study was to create a simple screening test for patients with mild cognitive impairment (MCI) and Alzheimer's disease (AD) by focusing on non-amnestic symptoms. Age-matched healthy controls (age 75.3±6.8), patients with MCI (76.5±5.5), and AD (78.2±5.0) participated in this study. They carried out mental rotation tasks targeting geometric graphics or alphabetical characters with three rotating angles (0°, 90°, and 180°) and indicated the correct answer. Response accuracy and reaction time were recorded along with their eye movements using an eye tracker. To quantify their visual processing strategy, the run count ratio (RC ratio) was calculated by dividing the mean number of fixations in incorrect answers by that in correct answers. AD patients showed lower accuracy and longer reaction time than controls. They also showed a significantly greater number of fixation and smaller saccade amplitude than controls, while fixation duration did not differ significantly. The RC ratio was higher for AD, followed by MCI and control groups. By setting the cut-off value to 0.47 in the 180° rotating angle task, we could differentiate MCI patients from controls with a probability of 80.0%. We established a new screening system for dementia patients by evaluating visuospatial function. The RC ratio during a mental rotation task is useful for discriminating MCI patients from controls.

  16. Energy absorption by a magnetic nanoparticle suspension in a rotating field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raikher, Yu. L.; Stepanov, V. I., E-mail: stepanov@icmm.ru

    Heat generation by viscous dissipation in a dilute suspension of single-domain ferromagnetic particles in a rotating magnetic field is analyzed by assuming that the suspended particles have a high magnetic rigidity. The problem is solved by using a kinetic approach based on a rotational diffusion equation. Behavior of specific loss power (SLP) as a function of field strength H and frequency {omega} is examined at constant temperature. SLP increases as either of these parameters squared when the other is constant, eventually approaching a saturation value. The function SLP(H, {omega}) can be used to determine optimal and admissible ranges of magneticallymore » induced heating.« less

  17. Modification of growth interface of CdZnTe crystals in THM process by ACRT

    NASA Astrophysics Data System (ADS)

    Zhou, Boru; Jie, Wanqi; Wang, Tao; Yin, Liying; Yang, Fan; Zhang, Binbin; Xi, Shouzhi; Dong, Jiangpeng

    2018-02-01

    The accelerated crucible rotation technique (ACRT) was introduced in the traveling heater method (THM) growth process of detector-grade CdZnTe (CZT) crystals to regulate the convection in the melt and to modify the growth interface morphology. Several ingots with the diameter of 53 mm were grown by THM with/without ACRT. The ingots were quenched during the growth to show both macroscopic and microscopic morphologies of the growth interfaces. The results show that by using ACRT the growth interface can be changed from a concave one to the flat or even convex one depending on the ACRT parameters, which is favorable for reducing nucleation in the melt to get larger CZT grains. Meanwhile, by using ACRT in THM process, the microscopic interface was changed from a diffused one to cellular or even planar one (at suitable ACRT parameters), through which the trapped Te inclusions was decreased for one order. An ingot grown by THM with constant rotation rate of 40 rpm was also grown, which have also reduced the interface curvature in macro-scale and Te inclusions to some extent, but the effects are not as significant as ACRT with high crucible rotation rate.

  18. The value of physical examination in the diagnosis of hip osteoarthritis.

    PubMed

    Chong, Timothy; Don, Darren W; Kao, Ming-Chih; Wong, Dexter; Mitra, Raj

    2013-01-01

    To compare the sensitivity of physical examination (internal rotation of the hip) with radiographs (using the Kellgren-Lawrence grading scale) in the diagnosis of clinically significant hip osteoarthritis. Case Series, Retrospective chart review of hip pain patients that underwent fluoroscopically guided hip steroid and anesthetic injections. 10 patients with hip pain patients seen at an academic outpatient center over a 2 year period were analyzed. Fluoroscopically guided hip steroid and anesthetic injection. Pain relief and change in VAS pain score after intra-articular hip steroid and lidocaine injection was the main outcome measure. Based on Fisher's exact test, there was no association between severity of radiographic hip arthritis and pain relief with intra-articular anesthetic/steroid injection (p=0.45). Physical examination (provocative hip internal rotation) however was associated with a significant decrease in VAS pain score after intra-articular lidocaine and corticosteroid hip injection (p=0.022). Simple hip radiographs alone are not sufficient to diagnose clinically significant hip osteoarthritis. Physical examination (hip internal rotation) was found to be more accurate than simple radiographs in the diagnosis of clinically significant hip osteoarthritis. Radiographs seem to best utilized when they are an extension of the physical examination and patient history.

  19. Analogies between Kirchhoff plates and functionally graded Saint-Venant beams under torsion

    NASA Astrophysics Data System (ADS)

    Barretta, Raffaele; Luciano, Raimondo

    2015-05-01

    Exact solutions of elastic Kirchhoff plates are available only for special geometries, loadings and kinematic boundary constraints. An effective solution procedure, based on an analogy between functionally graded orthotropic Saint-Venant beams under torsion and inhomogeneous isotropic Kirchhoff plates, with no kinematic boundary constraints, is proposed. The result extends the one contributed in Barretta (Acta Mech 224(12):2955-2964, 2013) for the special case of homogeneous Saint-Venant beams under torsion. Closed-form solutions for displacement, bending-twisting moment and curvature fields of an elliptic plate, corresponding to a functionally graded orthotropic beam, are evaluated. A new benchmark for computational mechanics is thus provided.

  20. Rotation of hard particles in a soft matrix

    NASA Astrophysics Data System (ADS)

    Yang, Weizhu; Liu, Qingchang; Yue, Zhufeng; Li, Xiaodong; Xu, Baoxing

    Soft-hard materials integration is ubiquitous in biological materials and structures in nature and has also attracted growing attention in the bio-inspired design of advanced functional materials, structures and devices. Due to the distinct difference in their mechanical properties, the rotation of hard phases in soft matrixes upon deformation has been acknowledged, yet is lack of theory in mechanics. In this work, we propose a theoretical mechanics framework that can describe the rotation of hard particles in a soft matrix. The rotation of multiple arbitrarily shaped, located and oriented particles with perfectly bonded interfaces in an elastic soft matrix subjected to a far-field tensile loading is established and analytical solutions are derived by using complex potentials and conformal mapping methods. Strong couplings and competitions of the rotation of hard particles among each other are discussed by investigating numbers, relative locations and orientations of particles in the matrix at different loading directions. Extensive finite element analyses are performed to validate theoretical solutions and good agreement of both rotation and stress field between them are achieved. Possible extensions of the present theory to non-rigid particles, viscoelastic matrix and imperfect bonding are also discussed. Finally, by taking advantage of the rotation of hard particles, we exemplify an application in a conceptual design of soft-hard material integrated phononic crystal and demonstrate that phononic band gaps can be successfully tuned with a high accuracy through the mechanical tension-induced rotation of hard particles. The present theory established herein is expected to be of immediate interests to the design of soft-hard materials integration based functional materials, structures and devices with tunable performance via mechanical rotation of hard phases.

  1. An immediate effect of axial neck rotation training with real time visual feedback using a smartphone inclinometer on improvement in axial neck rotation function.

    PubMed

    Park, Kyue-Nam; Kwon, Oh-Yun; Kim, Si-Hyun; Jeon, In-Cheol

    2017-03-01

    The purpose of this study was to compare the immediate effects of axial neck rotation training (Axi-NRT) with and without real-time visual feedback (VF) using a smartphone inclinometer on the range of motion (ROM) for axial neck rotation and the onset of compensatory neck lateral bending and extension during active neck rotation. Twenty participants with restricted ROM for neck rotation but no neck pain (21.1 ± 1.6 years and 8 males, 12 females) were recruited for Axi-NRT with VF, and twenty age- and gender-matched participants with restricted ROM for neck rotation were recruited for Axi-NRT without VF. Changes in ROM for neck rotation and the onset time of compensatory neck movement during active neck rotation were measured using an electromagnetic tracking system. Axi-NRT with VF was more effective in increasing ROM for neck rotation and decreasing and delaying the onset of compensatory neck movements during active neck rotation compared with Axi-NRT without VF. Repeated Axi-NRT using VF is useful to educate participants in maintaining the axis of the cervical spine and to increase ROM for axial neck rotation with less compensatory neck motion in participants with a restricted range of neck rotations.

  2. A new Morse-oscillator based Hamiltonian for H 3+: Calculation of line strengths

    NASA Astrophysics Data System (ADS)

    Jensen, Per; Špirko, V.

    1986-07-01

    In two recent publications [V. Špirko, P. Jensen, P. R. Bunker, and A. Čejchan, J. Mol. Spectrosc.112, 183-202 (1985); P. Jensen, V. Špirko, and P. R. Bunker, J. Mol. Spectrosc.115, 269-293 (1986)], we have described the development of Morse oscillator adapted rotation-vibration Hamiltonians for equilateral triangular X3 and Y2X molecules, and we have used these Hamiltonians to calculate the rotation-vibration energies for H 3+ and its X3+ and Y2X+ isotopes from ab initio potential energy functions. The present paper presents a method for calculating rotation-vibration line strengths of H 3+ and its isotopes using an ab initio dipole moment function [G. D. Carney and R. N. Porter, J. Chem. Phys.60, 4251-4264 (1974)] together with the energies and wave-functions obtained by diagonalization of the Morse oscillator adapted Hamiltonians. We use this method for calculating the vibrational transition moments involving the lowest vibrational states of H 3+, D 3+, H 2D +, and D 2H +. Further, we calculate the line strengths of the low- J transitions in the rotational spectra of H 3+ in the vibrational ground state and in the ν1 and ν2 states. We hope that the calculations presented will facilitate the search for further rotation-vibration transitions of H 3+ and its isotopes.

  3. Effects of 8 Weeks’ Specific Physical Training on the Rotator Cuff Muscle Strength and Technique of Javelin Throwers

    PubMed Central

    Kim, Hyeyoung; Lee, Youngsun; Shin, Insik; Kim, Kitae; Moon, Jeheon

    2014-01-01

    [Purpose] For maximum efficiency and to prevent injury during javelin throwing, it is critical to maintain muscle balance and coordination of the rotator cuff and the glenohumeral joint. In this study, we investigated the change in the rotator cuff muscle strength, throw distance and technique of javelin throwers after they had performed a specific physical training that combined elements of weight training, function movement screen training, and core training. [Subjects] Ten javelin throwers participated in this study: six university athletes in the experimental group and four national-level athletes in the control group. [Methods] The experimental group performed 8 weeks of the specific physical training. To evaluate the effects of the training, measurements were performed before and after the training for the experimental group. Measurements comprised anthropometry, isokinetic muscle strength measurements, the function movement screen test, and movement analysis. [Results] After the specific physical training, the function movement screen score and external and internal rotator muscle strength showed statistically significant increases. Among kinematic factors, only pull distance showed improvement after training. [Conclusion] Eight weeks of specific physical training for dynamic stabilizer muscles enhanced the rotator cuff muscle strength, core stability, throw distance, and flexibility of javelin throwers. These results suggest that specific physical training can be useful for preventing shoulder injuries and improving the performance for javelin throwers. PMID:25364111

  4. Effects of 8 weeks' specific physical training on the rotator cuff muscle strength and technique of javelin throwers.

    PubMed

    Kim, Hyeyoung; Lee, Youngsun; Shin, Insik; Kim, Kitae; Moon, Jeheon

    2014-10-01

    [Purpose] For maximum efficiency and to prevent injury during javelin throwing, it is critical to maintain muscle balance and coordination of the rotator cuff and the glenohumeral joint. In this study, we investigated the change in the rotator cuff muscle strength, throw distance and technique of javelin throwers after they had performed a specific physical training that combined elements of weight training, function movement screen training, and core training. [Subjects] Ten javelin throwers participated in this study: six university athletes in the experimental group and four national-level athletes in the control group. [Methods] The experimental group performed 8 weeks of the specific physical training. To evaluate the effects of the training, measurements were performed before and after the training for the experimental group. Measurements comprised anthropometry, isokinetic muscle strength measurements, the function movement screen test, and movement analysis. [Results] After the specific physical training, the function movement screen score and external and internal rotator muscle strength showed statistically significant increases. Among kinematic factors, only pull distance showed improvement after training. [Conclusion] Eight weeks of specific physical training for dynamic stabilizer muscles enhanced the rotator cuff muscle strength, core stability, throw distance, and flexibility of javelin throwers. These results suggest that specific physical training can be useful for preventing shoulder injuries and improving the performance for javelin throwers.

  5. Kinematic analysis of hip and knee rotation and other contributors to ballet turnout.

    PubMed

    Quanbeck, Amy E; Russell, Jeffrey A; Handley, Sara C; Quanbeck, Deborah S

    2017-02-01

    Turnout, or external rotation (ER) of the lower extremities, is essential in ballet. The purpose of this study was to utilise physical examination and a biomechanical method for obtaining functional kinematic data using hip and knee joint centres to identify the relative turnout contributions from hip rotation, femoral anteversion, knee rotation, tibial torsion, and other sources. Ten female dancers received a lower extremity alignment assessment, including passive hip rotation, femoral anteversion, tibial torsion, weightbearing foot alignment, and Beighton hypermobility score. Next, turnout was assessed using plantar pressure plots and three-dimensional motion analysis; participants performed turnout to ballet first position on both a plantar pressure mat and friction-reducing discs. A retro-reflective functional marker motion capture system mapped the lower extremities and hip and knee joint centres. Mean total turnout was 129±15.7° via plantar pressure plots and 135±17.8° via kinematics. Bilateral hip ER during turnout was 49±10.2° (36% of total turnout). Bilateral knee ER during turnout was 41±5.9° (32% of total turnout). Hip ER contribution to total turnout measured kinematically was less than expected compared to other studies, where hip ER was determined without functional kinematic data. Knee ER contributed substantially more turnout than expected or previously reported. This analysis method allows precise assessment of turnout contributors.

  6. Effects of local microwave diathermy on shoulder pain and function in patients with rotator cuff tendinopathy in comparison to subacromial corticosteroid injections: a single-blind randomized trial.

    PubMed

    Rabini, Alessia; Piazzini, Diana B; Bertolini, Carlo; Deriu, Laura; Saccomanno, Maristella F; Santagada, Domenico A; Sgadari, Antonio; Bernabei, Roberto; Fabbriciani, Carlo; Marzetti, Emanuele; Milano, Giuseppe

    2012-04-01

    Single-blind randomized clinical trial, with a follow-up of 24 weeks. To determine the effects of hyperthermia via localized microwave diathermy on pain and disability in comparison to subacromial corticosteroid injections in patients with rotator cuff tendinopathy. Hyperthermia improves symptoms and function in several painful musculoskeletal disorders. However, the effects of microwave diathermy in rotator cuff tendinopathy have not yet been established. Ninety-two patients with rotator cuff tendinopathy and pain lasting for at least 3 months were recruited from the outpatient clinic of the Department of Orthopaedics and Traumatology, University Hospital, Rome, Italy. Participants were randomly allocated to either local microwave diathermy or subacromial corticosteroids. The primary outcome measure was the short form of the Disabilities of the Arm, Shoulder and Hand Questionnaire (QuickDASH). Secondary outcome measures were the Constant-Murley shoulder outcome score and a visual analog scale for pain assessment. At the end of treatment and at follow-up, both treatment groups experienced improvements in all outcome measures relative to baseline values. Changes over time in QuickDASH, Constant-Murley, and visual analog scale scores were not different between treatment arms. In patients with rotator cuff tendinopathy, the effects of localized microwave diathermy on disability, shoulder function, and pain are equivalent to those elicited by subacromial corticosteroid injections.

  7. Large Critical Shoulder Angle Has Higher Risk of Tendon Retear After Arthroscopic Rotator Cuff Repair.

    PubMed

    Li, Hong; Chen, Yuzhou; Chen, Jiwu; Hua, Yinghui; Chen, Shiyi

    2018-05-01

    The critical shoulder angle (CSA) is the angle created between the superior and inferior bone margins of the glenoid and the most lateral border of the acromion. A few studies recently investigated the relation between CSA and functional outcomes after rotator cuff repair. However, there is a lack of research investigating the effect of CSA on postoperative tendon integrity after rotator cuff repair. To assess the effects of the CSA on postoperative tendon integrity after rotator cuff repair. Cohort study; Level of evidence, 3. All patients who underwent rotator cuff repair for full-thickness supraspinatus tears by 1 senior surgeon between January 2010 and January 2014 were included in this study. All patients had standardized anteroposterior shoulder radiographs the day before surgery. CSA and acromial index (AI) were measured. AI was derived by measuring the distance from the glenoid plane to the lateral border of the acromion and dividing it by the distance from the glenoid plane to the lateral aspect of the humeral head. Functional scores-including American Shoulder and Elbow Surgeons shoulder evaluation form, modified University of California at Los Angeles score, Constant-Murley score, and visual analog scale for pain-were used to evaluate shoulder function at a minimum follow-up of 2 years. Meanwhile, magnetic resonance imaging examinations were performed to evaluate rotator cuff integrity according to the Sugaya method and the signal/noise quotient (SNQ) of the rotator cuff tendon. A total of 90 patients were included in this study: 42 patients with a single-row repair and 48 with a double-row repair. There was a significant positive correlation between CSA or AI and tendon SNQ. On the basis of CSA, the patients were divided into 2 groups: large CSA (>38°) and control (CSA ≤38°). At final follow-up, the large CSA group and the control CSA group demonstrated no significant differences in American Shoulder and Elbow Surgeons, University of California at Los Angeles, Constant, and visual analog scale scores. Postoperative magnetic resonance imaging revealed that the large CSA group had 9 cases of retear, with a significantly higher retear rate than the control group (15% vs 0%, P = .03). Furthermore, the tendon SNQ of the large CSA group was significantly greater than that of the control group. CSA did not appear to influence postoperative functional outcomes, while those in the large CSA group had poor tendon integrity after rotator cuff repair. These findings indicate that a large CSA is associated with an increased risk of rotator cuff tendon retear after repair.

  8. Maple procedures for the coupling of angular momenta. IX. Wigner D-functions and rotation matrices

    NASA Astrophysics Data System (ADS)

    Pagaran, J.; Fritzsche, S.; Gaigalas, G.

    2006-04-01

    The Wigner D-functions, Dpqj(α,β,γ), are known for their frequent use in quantum mechanics. Defined as the matrix elements of the rotation operator Rˆ(α,β,γ) in R and parametrized in terms of the three Euler angles α, β, and γ, these functions arise not only in the transformation of tensor components under the rotation of the coordinates, but also as the eigenfunctions of the spherical top. In practice, however, the use of the Wigner D-functions is not always that simple, in particular, if expressions in terms of these and other functions from the theory of angular momentum need to be simplified before some computations can be carried out in detail. To facilitate the manipulation of such Racah expressions, here we present an extension to the RACAH program [S. Fritzsche, Comput. Phys. Comm. 103 (1997) 51] in which the properties and the algebraic rules of the Wigner D-functions and reduced rotation matrices are implemented. Care has been taken to combine the standard knowledge about the rotation matrices with the previously implemented rules for the Clebsch-Gordan coefficients, Wigner n-j symbols, and the spherical harmonics. Moreover, the application of the program has been illustrated below by means of three examples. Program summaryTitle of program:RACAH Catalogue identifier:ADFv_9_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADFv_9_0 Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Catalogue identifier of previous version: ADFW, ADHW, title RACAH Journal reference of previous version(s): S. Fritzsche, Comput. Phys. Comm. 103 (1997) 51; S. Fritzsche, S. Varga, D. Geschke, B. Fricke, Comput. Phys. Comm. 111 (1998) 167; S. Fritzsche, T. Inghoff, M. Tomaselli, Comput. Phys. Comm. 153 (2003) 424. Does the new version supersede the previous one: Yes, in addition to the spherical harmonics and recoupling coefficients, the program now supports also the occurrence of the Wigner rotation matrices in the algebraic expressions to be evaluated. Licensing provisions:None Computer for which the program is designed and others on which it is operable: All computers with a license for the computer algebra package Maple [Maple is a registered trademark of Waterloo Maple Inc.] Installations:University of Kassel (Germany) Operating systems under which the program has been tested: Linux 8.2+ Program language used:MAPLE, Release 8 and 9 Memory required to execute with typical data:10-50 MB No. of lines in distributed program, including test data, etc.:52 653 No. of bytes in distributed program, including test data, etc.:1 195 346 Distribution format:tar.gzip Nature of the physical problem: The Wigner D-functions and (reduced) rotation matrices occur very frequently in physical applications. They are known not only as the (infinite) representation of the rotation group but also to obey a number of integral and summation rules, including those for their orthogonality and completeness. Instead of the direct computation of these matrices, therefore, one first often wishes to find algebraic simplifications before the computations can be carried out in practice. Reasons for new version: The RACAH program has been found an efficient tool during recent years, in order to evaluate and simplify expressions from Racah's algebra. Apart from the Wigner n-j symbols ( j=3,6,9) and spherical harmonics, we now extended the code to allow for Wigner rotation matrices. This extension will support the study of those quantum processes especially where different axis of quantization occurs in course of the theoretical deviations. Summary of revisions: In a revised version of the RACAH program [S. Fritzsche, Comput. Phys. Comm. 103 (1997) 51; S. Fritzsche, T. Inghoff, M. Tomaselli, Comput. Phys. Comm. 153 (2003) 424], we now also support the occurrence of the Wigner D-functions and reduced rotation matrices. By following our previous design, the (algebraic) properties of these rotation matrices as well as a number of summation and integration rules are implemented to facilitate the algebraic simplification of expressions from the theories of angular momentum and the spherical tensor operators. Restrictions onto the complexity of the problem: The definition as well as the properties of the rotation matrices, as used in our implementation, are based mainly on the book of Varshalovich et al. [D.A. Varshalovich, A.N. Moskalev, V.K. Khersonskii, Quantum Theory of Angular Momentum, World Scientific, Singapore, 1988], Chapter 4. From this monograph, most of the relations involving the Wigner D-functions and rotation matrices are taken into account although, in practice, only a rather selected set was needed to be implemented explicitly owing to the symmetries of these functions. In the integration over the rotation matrices, products of up to three Wigner D-functions or reduced matrices (with the same angular arguments) are recognized and simplified properly; for the integration over a solid angle, however, the domain of integration must be specified for the Euler angles α and γ. This restriction arose because MAPLE does not generate a constant of integration when the limits in the integral are omitted. For any integration over the angle β the range of the integration, if omitted, is always taken from 0 to π. Unusual features of the program: The RACAH program is designed for interactive use that allows a quick and algebraic evaluation of (complex) expression from Racah's algebra. It is based on a number of well-defined data structures that are now extended to incorporate the Wigner rotation matrices. For these matrices, the transformation properties, sum rules, recursion relations, as well as a variety of special function expansions have been added to the previous functionality of the RACAH program. Moreover, the knowledge about the orthogonality as well as the completeness of the Wigner D-functions is also implemented. Typical running time:All the examples presented in Section 4 take only a few seconds on a 1.5 GHz Pentium Pro computer.

  9. Influence of functionally graded pores on bone ingrowth in cementless hip prosthesis: a finite element study using mechano-regulatory algorithm.

    PubMed

    Tarlochan, Faris; Mehboob, Hassan; Mehboob, Ali; Chang, Seung-Hwan

    2018-06-01

    Cementless hip prostheses with porous outer coating are commonly used to repair the proximally damaged femurs. It has been demonstrated that stability of prosthesis is also highly dependent on the bone ingrowth into the porous texture. Bone ingrowth is influenced by the mechanical environment produced in the callus. In this study, bone ingrowth into the porous structure was predicted by using a mechano-regulatory model. Homogenously distributed pores (200 and 800 [Formula: see text]m in diameter) and functionally graded pores along the length of the prosthesis were introduced as a porous coating. Bone ingrowth was simulated using 25 and 12 [Formula: see text]m micromovements. Load control simulations were carried out instead of traditionally used displacement control. Spatial and temporal distributions of tissues were predicted in all cases. Functionally graded pore decreasing models gave the most homogenous bone distribution, the highest bone ingrowth (98%) with highest average Young's modulus of all tissue phenotypes approximately 4.1 GPa. Besides this, the volume of the initial callus increased to 8.33% in functionally graded pores as compared to the 200 [Formula: see text]m pore size models which increased the bone volume. These findings indicate that functionally graded porous surface promote bone ingrowth efficiently which can be considered to design of surface texture of hip prosthesis.

  10. Investigation of compressible vortex flow characteristics

    NASA Technical Reports Server (NTRS)

    Muirhead, V. U.

    1977-01-01

    The nature of intense air vortices was studied and the factors which determine the intensity and rate of decay of both single and pairs of vortices were investigated. Vortex parameters of axial pressure differential, circulation, outflow rates, separation distance and directions of rotation were varied. Unconfined vortices, generated by a single rotating cage, were intensified by an increasing axial pressure gradient. Breakdown occurred when the axial gradient became negligible. The core radius was a function of the axial gradient. Dual vortices, generated by two counterrotating cages, rotated opposite to the attached cages. With minimum spacing only one vortex was formed which rotated in a direction opposite to the attached cage. When one cage rotated at half the speed of the other cage, one vortex formed at the higher speed cage rotating in the cage direction.

  11. Rotational control of computer generated holograms.

    PubMed

    Preece, Daryl; Rubinsztein-Dunlop, Halina

    2017-11-15

    We develop a basis for three-dimensional rotation of arbitrary light fields created by computer generated holograms. By adding an extra phase function into the kinoform, any light field or holographic image can be tilted in the focal plane with minimized distortion. We present two different approaches to rotate an arbitrary hologram: the Scheimpflug method and a novel coordinate transformation method. Experimental results are presented to demonstrate the validity of both proposed methods.

  12. Rotational Invariance of the 2d Spin - Spin Correlation Function

    NASA Astrophysics Data System (ADS)

    Pinson, Haru

    2012-09-01

    At the critical temperature in the 2d Ising model on the square lattice, we establish the rotational invariance of the spin-spin correlation function using the asymptotics of the spin-spin correlation function along special directions (McCoy and Wu in the two dimensional Ising model. Harvard University Press, Cambridge, 1973) and the finite difference Hirota equation for which the spin-spin correlation function is shown to satisfy (Perk in Phys Lett A 79:3-5, 1980; Perk in Proceedings of III international symposium on selected topics in statistical mechanics, Dubna, August 22-26, 1984, JINR, vol II, pp 138-151, 1985).

  13. Disruption of intracardiac flow patterns in the newborn infant.

    PubMed

    Groves, Alan M; Durighel, Giuliana; Finnemore, Anna; Tusor, Nora; Merchant, Nazakat; Razavi, Reza; Hajnal, Jo V; Edwards, A David

    2012-04-01

    Consistent patterns of rotational intracardiac flow have been demonstrated in the healthy adult human heart. Intracardiac rotational flow patterns are hypothesized to assist in the maintenance of kinetic energy of inflowing blood, augmenting cardiac function. Newborn cardiac function is known to be suboptimal secondary to decreased receptor number and sympathetic innervation, increased afterload, and increased reliance on atrial contraction to support ventricular filling. Patterns of intracardiac flow in the newborn have not previously been examined. Whereas 5 of the 13 infants studied showed significant evidence of rotational flow within the right atrium, 8 infants showed little or no rotational flow. Presence or absence of rotational flow was not related to gestational age, birth weight, postnatal age, atrial size, or image quality. Despite absence of intra-atrial rotational flow, atrioventricular valve flow into the left and right ventricles later in the cardiac cycle could be seen, suggesting that visualization techniques were adequate. While further study is required to assess its exact consequences on cardiac mechanics and energetics, disruption to intracardiac flow patterns could be another contributor to the multifactorial sequence that produces newborn circulatory failure. We studied 13 newborn infants, using three-dimensional (3D) cardiac magnetic resonance phase-contrast imaging (spatial resolution 0.84 mm, temporal resolution 22.6 ms) performed without sedation/anesthesia.

  14. The Role of Platelet Rich Plasma (PRP) and Other Biologics for Rotator Cuff Repair.

    PubMed

    Greenspoon, Joshua A; Moulton, Samuel G; Millett, Peter J; Petri, Maximilian

    2016-01-01

    Surgical treatment of rotator cuff tears has consistently demonstrated good clinical and functional outcomes. However, in some cases, the rotator cuff fails to heal. While improvements in rotator cuff constructs and biomechanics have been made, the role of biologics to aid healing is currently being investigated. A selective literature search was performed and personal surgical experiences are reported. Biologic augmentation of rotator cuff repairs can for example be performed wtableith platelet-rich plasma (PRP) and mesenchymal stem cells (MSCs). Clinical results on PRP application have been controversial. Application of MSCs has shown promise in animal studies, but clinical data on its effectiveness is presently lacking. The role of Matrix Metalloproteinase (MMP) inhibitors is another interesting field for potential targeted drug therapy after rotator cuff repair. Large randomized clinical studies need to confirm the benefit of these approaches, in order to eventually lower retear rates and improve clinical outcomes after rotator cuff repair.

  15. Improved turbulence models based on large eddy simulation of homogeneous, incompressible turbulent flows

    NASA Technical Reports Server (NTRS)

    Bardino, J.; Ferziger, J. H.; Reynolds, W. C.

    1983-01-01

    The physical bases of large eddy simulation and subgrid modeling are studied. A subgrid scale similarity model is developed that can account for system rotation. Large eddy simulations of homogeneous shear flows with system rotation were carried out. Apparently contradictory experimental results were explained. The main effect of rotation is to increase the transverse length scales in the rotation direction, and thereby decrease the rates of dissipation. Experimental results are shown to be affected by conditions at the turbulence producing grid, which make the initial states a function of the rotation rate. A two equation model is proposed that accounts for effects of rotation and shows good agreement with experimental results. In addition, a Reynolds stress model is developed that represents the turbulence structure of homogeneous shear flows very well and can account also for the effects of system rotation.

  16. In-Flight Performance of the Polarization Modulator in the CLASP Rocket Experiment

    NASA Technical Reports Server (NTRS)

    Ishikawa, Shin-nosuke; Shimizu, Toshifumi; Kano, Ryohei; Bando, Takamasa; Ishikawa, Ryoko; Giono, Gabriel; Beabout, Dyana L.; Beabout, Brent L.; Nakayama, Satoshi; Tajima, Takao

    2016-01-01

    We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman-alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman-alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non-uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.

  17. In-flight performance of the polarization modulator in the CLASP rocket experiment

    NASA Astrophysics Data System (ADS)

    Ishikawa, Shin-nosuke; Shimizu, Toshifumi; Kano, Ryohei; Bando, Takamasa; Ishikawa, Ryoko; Giono, Gabriel; Beabout, Dyana L.; Beabout, Brent L.; Nakayama, Satoshi; Tajima, Takao

    2016-07-01

    We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman-alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman-alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non- uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.

  18. The bacterial flagellar switch complex is getting more complex

    PubMed Central

    Cohen-Ben-Lulu, Galit N; Francis, Noreen R; Shimoni, Eyal; Noy, Dror; Davidov, Yaacov; Prasad, Krishna; Sagi, Yael; Cecchini, Gary; Johnstone, Rose M; Eisenbach, Michael

    2008-01-01

    The mechanism of function of the bacterial flagellar switch, which determines the direction of flagellar rotation and is essential for chemotaxis, has remained an enigma for many years. Here we show that the switch complex associates with the membrane-bound respiratory protein fumarate reductase (FRD). We provide evidence that FRD binds to preparations of isolated switch complexes, forms a 1:1 complex with the switch protein FliG, and that this interaction is required for both flagellar assembly and switching the direction of flagellar rotation. We further show that fumarate, known to be a clockwise/switch factor, affects the direction of flagellar rotation through FRD. These results not only uncover a new component important for switching and flagellar assembly, but they also reveal that FRD, an enzyme known to be primarily expressed and functional under anaerobic conditions in Escherichia coli, nonetheless, has important, unexpected functions under aerobic conditions. PMID:18337747

  19. van der Waals Heterostructures with High Accuracy Rotational Alignment.

    PubMed

    Kim, Kyounghwan; Yankowitz, Matthew; Fallahazad, Babak; Kang, Sangwoo; Movva, Hema C P; Huang, Shengqiang; Larentis, Stefano; Corbet, Chris M; Taniguchi, Takashi; Watanabe, Kenji; Banerjee, Sanjay K; LeRoy, Brian J; Tutuc, Emanuel

    2016-03-09

    We describe the realization of van der Waals (vdW) heterostructures with accurate rotational alignment of individual layer crystal axes. We illustrate the approach by demonstrating a Bernal-stacked bilayer graphene formed using successive transfers of monolayer graphene flakes. The Raman spectra of this artificial bilayer graphene possess a wide 2D band, which is best fit by four Lorentzians, consistent with Bernal stacking. Scanning tunneling microscopy reveals no moiré pattern on the artificial bilayer graphene, and tunneling spectroscopy as a function of gate voltage reveals a constant density of states, also in agreement with Bernal stacking. In addition, electron transport probed in dual-gated samples reveals a band gap opening as a function of transverse electric field. To illustrate the applicability of this technique to realize vdW heterostructuctures in which the functionality is critically dependent on rotational alignment, we demonstrate resonant tunneling double bilayer graphene heterostructures separated by hexagonal boron-nitride dielectric.

  20. Eye-rotation-induced spatial reorganization of horizontal connections in field 17 of the cat cortex.

    PubMed

    Shkorbatova, P Yu; Alekseenko, S V

    2006-06-01

    Six cats with rotation of one or both eyes (strabismus) produced surgically in the early postnatal period demonstrated torsional deviation of the eyes by 10-20 degrees in addition to the rotation. The spatial distribution of retrograde labeled neurons in field 17 was studied by microiontophoretic administration of horseradish peroxidase into individual cortical columns in fields 17 and 18. These studies showed that rotation of the eyes increased the extent of horizontal neuronal connections in field 17 along the projection of the vertical meridian of the field of vision. It is suggested that this reorganization of neuronal connections may support functional changes compensating for eye rotation, as described in the literature.

Top