Sample records for fundamental frequency fsubscript

  1. Effect of Age on F[subscript 0] Difference Limen and Concurrent Vowel Identification

    ERIC Educational Resources Information Center

    Vongpaisal, Tara; Pichora-Fuller, Margaret Kathleen

    2007-01-01

    Purpose: To investigate the effect of age on voice fundamental frequency (F[subscript 0]) difference limen (DL) and identification of concurrently presented vowels. Method: Fifteen younger and 15 older adults with normal audiometric thresholds in the speech range participated in 2 experiments. In Experiment 1, F[subscript 0] DLs were measured for…

  2. Depression Diagnoses and Fundamental Frequency-Based Acoustic Cues in Maternal Infant-Directed Speech

    ERIC Educational Resources Information Center

    Porritt, Laura L.; Zinser, Michael C.; Bachorowski, Jo-Anne; Kaplan, Peter S.

    2014-01-01

    F[subscript 0]-based acoustic measures were extracted from a brief, sentence-final target word spoken during structured play interactions between mothers and their 3- to 14-month-old infants and were analyzed based on demographic variables and DSM-IV Axis-I clinical diagnoses and their common modifiers. F[subscript 0] range (?F[subscript 0]) was…

  3. Phonetically Governed Voicing Onset and Offset in Preschool Children Who Stutter

    ERIC Educational Resources Information Center

    Arenas, Richard M.; Zebrowski, Patricia M.; Moon, Jerald B.

    2012-01-01

    Phonetically governed changes in the fundamental frequency (F[subscript 0]) of vowels that immediately precede and follow voiceless stop plosives have been found to follow consistent patterns in adults and children as young as four years of age. In the present study, F[subscript 0] onset and offset patterns in 14 children who stutter (CWS) and 14…

  4. Frequency Response of Synthetic Vocal Fold Models with Linear and Nonlinear Material Properties

    ERIC Educational Resources Information Center

    Shaw, Stephanie M.; Thomson, Scott L.; Dromey, Christopher; Smith, Simeon

    2012-01-01

    Purpose: The purpose of this study was to create synthetic vocal fold models with nonlinear stress-strain properties and to investigate the effect of linear versus nonlinear material properties on fundamental frequency (F[subscript 0]) during anterior-posterior stretching. Method: Three materially linear and 3 materially nonlinear models were…

  5. Acoustic Characteristics of Simulated Respiratory-Induced Vocal Tremor

    ERIC Educational Resources Information Center

    Lester, Rosemary A.; Story, Brad H.

    2013-01-01

    Purpose: The purpose of this study was to investigate the relation of respiratory forced oscillation to the acoustic characteristics of vocal tremor. Method: Acoustical analyses were performed to determine the characteristics of the intensity and fundamental frequency (F[subscript 0]) for speech samples obtained by Farinella, Hixon, Hoit, Story,…

  6. Influence of Analogy Instruction for Pitch Variation on Perceptual Ratings of Other Speech Parameters

    ERIC Educational Resources Information Center

    Tse, Andy C. Y.; Wong, Andus W-K.; Ma, Estella P-M.; Whitehill, Tara L.; Masters, Rich S. W.

    2013-01-01

    Purpose: "Analogy" is the similarity of different concepts on which a comparison can be based. Recently, an analogy of "waves at sea" was shown to be effective in modulating fundamental frequency (F[subscript 0]) variation. Perceptions of intonation were not examined, as the primary aim of the work was to determine whether…

  7. The Effect of Syllable Repetition Rate on Vocal Characteristics

    ERIC Educational Resources Information Center

    Topbas, Oya; Orlikoff, Robert F.; St. Louis, Kenneth O.

    2012-01-01

    This study examined whether mean vocal fundamental frequency ("F"[subscript 0]) or speech sound pressure level (SPL) varies with changes in syllable repetition rate. Twenty-four young adults (12 M and 12 F) repeated the syllables/p[inverted v]/,/p[inverted v]t[schwa]/, and/p[inverted v]t[schwa]k[schwa]/at a modeled "slow" rate of approximately one…

  8. Polynomial Interpolation and Sums of Powers of Integers

    ERIC Educational Resources Information Center

    Cereceda, José Luis

    2017-01-01

    In this note, we revisit the problem of polynomial interpolation and explicitly construct two polynomials in n of degree k + 1, P[subscript k](n) and Q[subscript k](n), such that P[subscript k](n) = Q[subscript k](n) = f[subscript k](n) for n = 1, 2,… , k, where f[subscript k](1), f[subscript k](2),… , f[subscript k](k) are k arbitrarily chosen…

  9. Fibonacci-Pell Hybridities

    ERIC Educational Resources Information Center

    Koshy, Thomas; Gao, Zhenguang

    2012-01-01

    We develop a recurrence satisfied by the Fibonacci and Pell families. We then use it to find explicit formulae and generating functions for the hybrids "F[subscript n]P[subscript n]", "L[subscript n]P[subscript n]", "F[subscript n]Q[subscript n]" and "L[subscript n]Q[subscript n]", where "F[subscript n]", "L[subscript n]", "P[subscript n]" and…

  10. Combinatorial Proofs of Honsberger-Type Identities

    ERIC Educational Resources Information Center

    Plaza, A.; Falcon, S.

    2008-01-01

    In this article, we consider some generalizations of Fibonacci numbers. We consider k-Fibonacci numbers (that follow the recurrence rule F[subscript k,n + 2] = kF[subscript k,n + 1] + F[subscript k,n]), the (k, l)-Fibonacci numbers (that follow the recurrence rule F[subscript k,n + 2] = kF[subscript k,n + 1] + lF[subscript k,n]), and the Fibonacci…

  11. What Does f[subscript xx]f[subscript yy] - f[superscript 2][subscript xy] Greater than 0 "Really" Mean?

    ERIC Educational Resources Information Center

    McCartin, Brian J.

    2008-01-01

    This note presents geometric and physical interpretations of the sufficient condition for a critical point to be a strict relative extremum: f[subscript xx]f[subscript yy] - f[superscript 2][subscript xy] greater than 0. The role of the double derivative f[subscript xy] in this inequality will be highlighted in these interpretations. (Contains 14…

  12. Analysis on Non-Resonance Standing Waves and Vibration Tracks of Strings

    ERIC Educational Resources Information Center

    Fang, Tian-Shen

    2007-01-01

    This paper presents an experimental technique to observe the vibration tracks of string standing waves. From the vibration tracks, we can analyse the vibration directions of harmonic waves. For the harmonic wave vibrations of strings, when the driving frequency f[subscript s] = Nf[subscript n] (N = 1, 2, 3, 4,...), both resonance and non-resonance…

  13. Lexical Tone Gestures

    ERIC Educational Resources Information Center

    Yi, Hao

    2017-01-01

    This dissertation investigates the lexical f[subscript 0] control in Mandarin within the framework of Articulatory Phonology (AP) in two experiments: an imitation study (Experiment 1) and an Electromagnetic Articulography production study (Experiment 2). Empirical results are accounted for by making reference to a gestural model of f[subscript o]…

  14. Showing Area Matters: A Work of Friction

    ERIC Educational Resources Information Center

    Van Domelen, David

    2010-01-01

    Typically, we teach the simplified friction equation of the form F[subscript s] = [mu][subscript s]N for static friction, where F[subscript s] is the maximum static friction, [mu][subscript s] is the coefficient of static friction, and "N" is the normal force pressing the surfaces together. However, this is a bit too simplified, and…

  15. Substituent effects in a series of 1,7-C[subscript 60](R[subscript F])[subscript 2] compounds (R[subscript F] = CF[subscript 3], C[subscript 2]F[subscript 5], n-C[subscrip 3]F[subscript 7], i-C[subscript 3]F[subscript 7], n-C[subscript 4]F[subscript 9], s-C[subscript 4]F[subscript 9], n-C[subscript 8]F[subscript 17]): electron affinities, reduction potentials and E(LUMO) values are not always correlated

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuvychko, Igor V.; Whitaker, James B.; Larson, Bryon W.

    2013-04-08

    A series of seven structurally-similar compounds with different pairs of R{sub F} groups were prepared, characterized spectroscopically, and studied by electrochemical methods (cyclic and square-wave voltammetry), low-temperature anion photoelectron spectroscopy, and DFT calculations (five of the compounds are reported here for the first time). This is the first time that a set of seven R{sub F} groups have been compared with respect to their relative effects on E{sub 1/2}(0/-), electron affinity (EA), and the DFT-calculated LUMO energy. The compounds, 1,7-C{sub 60}(R{sub F}){sub 2} (R{sub F} = CF{sub 3}, C{sub 2}F{sub 5}, i-C{sub 3}F{sub 7}, n-C{sub 3}F{sub 7}, s-C{sub 4}F{sub 9},more » n-C{sub 4}F{sub 9} and n-C{sub 8}F{sub 21}), were found to have statistically different electron affinities (EA), at the {+-}10 meV level of uncertainty, but virtually identical first reduction potentials, at the {+-}10 mV level of uncertainty. The lack of a correlation between EA and E{sub 1/2}(0/-), and between E(LUMO) and E{sub 1/2}(0/-), for such similar compounds is unprecedented and suggests that explanations for differences in figures of merit for materials and/or devices that are based on equating easily measurable E{sub 1/2}(0/-) values with EAs or E(LUMO) values should be viewed with caution. The solubilities of the seven compounds in toluene varied by nearly a factor of six, but in an unpredictable way, with the C{sub 2}F{sub 5} and s-C{sub 4}F{sub 9} compounds being the most soluble and the i-C{sub 3}F{sub 7} compound being the least soluble. The effects of the different R{sub F} groups on EAs, E(LUMO) values, and solubilities should help fluorine chemists choose the right R{sub F} group to design new materials with improved morphological, electronic, optical, and/or magnetic properties.« less

  16. Use of the "gl1" Mutant and the "CA-rop2" Transgenic Plants of "Arabidopsis thaliana" in the Biology Laboratory Course

    ERIC Educational Resources Information Center

    Zheng, Zhi-Liang

    2006-01-01

    This article describes the use of the "glabrous1 (g11)" mutant and constitutively active "(CA)-rop2" transgenic plants of "Arabidopsis thaliana" in teaching genetics laboratory for both high school and undergraduate students. The experiments provide students with F[subscript 1] and F[subscript 2] generations within a semester for genetic and…

  17. Focusing Light Rays Back to the Vertex of a Reflecting Parabolic Collector: The Equivalent of Dionysius Ear Effect in Optical Systems

    ERIC Educational Resources Information Center

    De Luca, R.; Fedullo, A.

    2009-01-01

    A vertical light ray coming from infinity is reflected by a primary parabolic mirror M[subscript 1] having focus at F[subscript 1]. At a small distance from F[subscript 1] a secondary mirror M[subscript 2], symmetric with respect to the vertical axis, is placed. One would like to find the analytic equation of the mirror M[subscript 2], so that all…

  18. Catalan's Intriguing Factorial Problem

    ERIC Educational Resources Information Center

    Koshy, Thomas

    2012-01-01

    This article investigates the numbers [image omitted], originally studied by Catalan. We re-confirm that they are indeed integers. Using the close relationship between them and the Catalan numbers C[subscript n], we develop some divisibility properties for C[subscript n]. In particular, we establish that [image omitted], where f[subscript k]…

  19. The Utility and Comparative Incremental Validity of the MMPI-2 and Trauma Symptom Inventory Validity Scales in the Detection of Feigned PTSD

    ERIC Educational Resources Information Center

    Efendov, Adele A.; Sellbom, Martin; Bagby, R. Michael

    2008-01-01

    The authors examined the comparative predictive capacity of the Trauma Symptom Inventory (TSI) Atypical Response Scale (ATR) and the standard set of Minnesota Multiphasic Personality Inventory-2 (MMPI-2) fake-bad validity scales (i.e., F, F[subscript B[prime

  20. The Indeterminate Case of Classical Static Friction When Coupled with Tension

    ERIC Educational Resources Information Center

    Hahn, Kenneth D.; Russell, Jacob M.

    2018-01-01

    It has been noted that the static friction force poses challenges for students and, at times, even their instructors. Unlike the gravitational force, which has a precise and unambiguous magnitude (F[subscript G] = mg), the magnitude and direction of the static friction force depend on other forces at play. Friction can be understood rather well in…

  1. A Comparison of Four Estimators of a Population Measure of Model Fit in Covariance Structure Analysis

    ERIC Educational Resources Information Center

    Zhang, Wei

    2008-01-01

    A major issue in the utilization of covariance structure analysis is model fit evaluation. Recent years have witnessed increasing interest in various test statistics and so-called fit indexes, most of which are actually based on or closely related to F[subscript 0], a measure of model fit in the population. This study aims to provide a systematic…

  2. Predicting fundamental frequency from mel-frequency cepstral coefficients to enable speech reconstruction.

    PubMed

    Shao, Xu; Milner, Ben

    2005-08-01

    This work proposes a method to reconstruct an acoustic speech signal solely from a stream of mel-frequency cepstral coefficients (MFCCs) as may be encountered in a distributed speech recognition (DSR) system. Previous methods for speech reconstruction have required, in addition to the MFCC vectors, fundamental frequency and voicing components. In this work the voicing classification and fundamental frequency are predicted from the MFCC vectors themselves using two maximum a posteriori (MAP) methods. The first method enables fundamental frequency prediction by modeling the joint density of MFCCs and fundamental frequency using a single Gaussian mixture model (GMM). The second scheme uses a set of hidden Markov models (HMMs) to link together a set of state-dependent GMMs, which enables a more localized modeling of the joint density of MFCCs and fundamental frequency. Experimental results on speaker-independent male and female speech show that accurate voicing classification and fundamental frequency prediction is attained when compared to hand-corrected reference fundamental frequency measurements. The use of the predicted fundamental frequency and voicing for speech reconstruction is shown to give very similar speech quality to that obtained using the reference fundamental frequency and voicing.

  3. The influence of fundamental frequency on perceived duration in spectrally comparable sounds

    PubMed Central

    Aalto, Daniel; Simko, Juraj; Vainio, Martti

    2017-01-01

    The perceived duration of a sound is affected by its fundamental frequency and intensity: higher sounds are judged to be longer, as are sounds with greater intensity. Since increasing intensity lengthens the perceived duration of the auditory object, and increasing the fundamental frequency increases the sound’s perceived loudness (up to ca. 3 kHz), frequency modulation of duration could be potentially explained by a confounding effect where the primary cause of the modulation would be variations in intensity. Here, a series of experiments are described that were designed to disentangle the contributions of fundamental frequency, intensity, and duration to perceived loudness and duration. In two forced-choice tasks, participants judged duration and intensity differences between two sounds varying simultaneously in intensity, fundamental frequency, fundamental frequency gliding range, and duration. The results suggest that fundamental frequency and intensity each have an impact on duration judgments, while frequency gliding range did not influence the present results. We also demonstrate that the modulation of perceived duration by sound fundamental frequency cannot be fully explained by the confounding relationship between frequency and intensity. PMID:28879063

  4. The influence of fundamental frequency on perceived duration in spectrally comparable sounds.

    PubMed

    Dawson, Caitlin; Aalto, Daniel; Simko, Juraj; Vainio, Martti

    2017-01-01

    The perceived duration of a sound is affected by its fundamental frequency and intensity: higher sounds are judged to be longer, as are sounds with greater intensity. Since increasing intensity lengthens the perceived duration of the auditory object, and increasing the fundamental frequency increases the sound's perceived loudness (up to ca. 3 kHz), frequency modulation of duration could be potentially explained by a confounding effect where the primary cause of the modulation would be variations in intensity. Here, a series of experiments are described that were designed to disentangle the contributions of fundamental frequency, intensity, and duration to perceived loudness and duration. In two forced-choice tasks, participants judged duration and intensity differences between two sounds varying simultaneously in intensity, fundamental frequency, fundamental frequency gliding range, and duration. The results suggest that fundamental frequency and intensity each have an impact on duration judgments, while frequency gliding range did not influence the present results. We also demonstrate that the modulation of perceived duration by sound fundamental frequency cannot be fully explained by the confounding relationship between frequency and intensity.

  5. Central Tendency and Dispersion Measures of the Fundamental Frequencies of Four Vowels as Produced by Two Year-Old and Four-Year Children.

    NASA Astrophysics Data System (ADS)

    Monroe, Roberta Lynn

    The intrinsic fundamental frequency effect among vowels is a vocalic phenomenon of adult speech in which high vowels have higher fundamental frequencies in relation to low vowels. Acoustic investigations of children's speech have shown that variability of the speech signal decreases as children's ages increase. Fundamental frequency measures have been suggested as an indirect metric for the development of laryngeal stability and coordination. Studies of the intrinsic fundamental frequency effect have been conducted among 8- and 9-year old children and in infants. The present study investigated this effect among 2- and 4-year old children. Eight 2-year old and eight 4-year old children produced four vowels, /ae/, /i/, /u/, and /a/, in CVC syllables. Three measures of fundamental frequency were taken. These were mean fundamental frequency, the intra-utterance standard deviation of the fundamental frequency, and the extent to which the cycle-to-cycle pattern of the fundamental frequency was predicted by a linear trend. An analysis of variance was performed to compare the two age groups, the four vowels, and the earlier and later repetitions of the CVC syllables. A significant difference between the two age groups was detected using the intra-utterance standard deviation of the fundamental frequency. Mean fundamental frequencies and linear trend analysis showed that voicing of the preceding consonant determined the statistical significance of the age-group comparisons. Statistically significant differences among the fundamental frequencies of the four vowels were not detected for either age group.

  6. 33 CFR 86.03 - Limits of fundamental frequencies.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of fundamental frequencies. To ensure a wide variety of whistle characteristics, the fundamental... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Limits of fundamental frequencies. 86.03 Section 86.03 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY...

  7. Measuring the rate of change of voice fundamental frequency in fluent speech during mental depression.

    PubMed

    Nilsonne, A; Sundberg, J; Ternström, S; Askenfelt, A

    1988-02-01

    A method of measuring the rate of change of fundamental frequency has been developed in an effort to find acoustic voice parameters that could be useful in psychiatric research. A minicomputer program was used to extract seven parameters from the fundamental frequency contour of tape-recorded speech samples: (1) the average rate of change of the fundamental frequency and (2) its standard deviation, (3) the absolute rate of fundamental frequency change, (4) the total reading time, (5) the percent pause time of the total reading time, (6) the mean, and (7) the standard deviation of the fundamental frequency distribution. The method is demonstrated on (a) a material consisting of synthetic speech and (b) voice recordings of depressed patients who were examined during depression and after improvement.

  8. [Fundamental frequency analysis - a contribution to the objective examination of the speaking and singing voice (author's transl)].

    PubMed

    Schultz-Coulon, H J

    1975-07-01

    The applicability of a newly developed fundamental frequency analyzer to diagnosis in phoniatrics is reviewed. During routine voice examination, the analyzer allows a quick and accurate measurement of fundamental frequency and sound level of the speaking voice, and of vocal range and maximum phonation time. By computing fundamental frequency histograms, the median fundamental frequency and the total pitch range can be better determined and compared. Objective studies of certain technical faculties of the singing voice, which usually are estimated subjectively by the speech therapist, may now be done by means of this analyzer. Several examples demonstrate the differences between correct and incorrect phonation. These studies compare the pitch perturbations during the crescendo and decrescendo of a swell-tone, and show typical traces of staccato, thrill and yodel. Conclusions of the study indicate that fundamental frequency analysis is a valuable supplemental method for objective voice examination.

  9. Perception of the fundamental frequencies of children's voices by trained and untrained listeners.

    PubMed

    Wilson, F B; Wellen, C J; Kimbarow, M L

    1983-10-01

    This study was designed to determine if trained voice clinicians were better than untrained listeners in judging differences in the fundamental frequencies of children's voices. We also attempted to determine the degree of difference in fundamental frequency necessary for accurate judgments. Finally, ability to perceive pitch differences in speaking voices was correlated with ability to judge puretone stimuli. Results indicated that trained clinicians were no better at judging average fundamental frequency than were untrained listeners. Both groups performed at chance level until differences in vocal fundamental frequency exceeded 20 Hz. Finally, there was no correlation between subjects' success on standardized puretone pitch tests and ability to judge average pitch in the speaking voice.

  10. Second-harmonic generation of a dual-frequency laser in a MgO:PPLN crystal.

    PubMed

    Kang, Ying; Yang, Suhui; Brunel, Marc; Cheng, Lijun; Zhao, Changming; Zhang, Haiyang

    2017-04-10

    A dual-frequency CW laser at a wavelength of 1.064 μm is frequency doubled in a MgO:PPLN nonlinear crystal. The fundamental dual-frequency laser has a tunable beat note from 125 MHz to 175 MHz. A laser-diode pumped fiber amplifier is used to amplify the dual-frequency fundamental output to a maximum power of 50 W before frequency doubling. The maximum output power of the green light is 1.75 W when the input fundamental power is 12 W, corresponding to a frequency doubling efficiency of 14.6%. After frequency doubling, green light with modulation frequencies in two bands from 125 MHz to 175 MHz and from 250 MHz to 350 MHz is achieved simultaneously. The relative intensities of the beat notes at the two bands can be adjusted by changing the relative intensities at different frequencies of the fundamental light. The spectral width and frequency stabilities of the beat notes in fundamental wave and green light are also measured, respectively. The modulated green light has potential applications in underwater ranging, communication, and imaging.

  11. Welding characteristics of 27, 40 and 67 kHz ultrasonic plastic welding systems using fundamental- and higher-resonance frequencies.

    PubMed

    Tsujino, Jiromaru; Hongoh, Misugi; Yoshikuni, Masafumi; Hashii, Hidekazu; Ueoka, Tetsugi

    2004-04-01

    The welding characteristics of 27, 40 and 67 kHz ultrasonic plastic welding systems that are driven at only the fundamental-resonance frequency vibration were compared, and also those of the welding systems that were driven at the fundamental and several higher resonance frequencies simultaneously were studied. At high frequency, welding characteristics can be improved due to the larger vibration loss of plastic materials. For welding of rather thin or small specimens, as the fundamental frequency of these welding systems is higher and the numbers of driven higher frequencies are driven simultaneously, larger welded area and weld strength were obtained.

  12. Characterizing resonant component in speech: A different view of tracking fundamental frequency

    NASA Astrophysics Data System (ADS)

    Dong, Bin

    2017-05-01

    Inspired by the nonlinearity and nonstationarity and the modulations in speech, Hilbert-Huang Transform and cyclostationarity analysis are employed to investigate the speech resonance in vowel in sequence. Cyclostationarity analysis is not directly manipulated on the target vowel, but on its intrinsic mode functions one by one. Thanks to the equivalence between the fundamental frequency in speech and the cyclic frequency in cyclostationarity analysis, the modulation intensity distributions of the intrinsic mode functions provide much information for the estimation of the fundamental frequency. To highlight the relationship between frequency and time, the pseudo-Hilbert spectrum is proposed to replace the Hilbert spectrum here. After contrasting the pseudo-Hilbert spectra of and the modulation intensity distributions of the intrinsic mode functions, it finds that there is usually one intrinsic mode function which works as the fundamental component of the vowel. Furthermore, the fundamental frequency of the vowel can be determined by tracing the pseudo-Hilbert spectrum of its fundamental component along the time axis. The later method is more robust to estimate the fundamental frequency, when meeting nonlinear components. Two vowels [a] and [i], picked up from a speech database FAU Aibo Emotion Corpus, are applied to validate the above findings.

  13. Predicting Achievable Fundamental Frequency Ranges in Vocalization Across Species

    PubMed Central

    Titze, Ingo; Riede, Tobias; Mau, Ted

    2016-01-01

    Vocal folds are used as sound sources in various species, but it is unknown how vocal fold morphologies are optimized for different acoustic objectives. Here we identify two main variables affecting range of vocal fold vibration frequency, namely vocal fold elongation and tissue fiber stress. A simple vibrating string model is used to predict fundamental frequency ranges across species of different vocal fold sizes. While average fundamental frequency is predominantly determined by vocal fold length (larynx size), range of fundamental frequency is facilitated by (1) laryngeal muscles that control elongation and by (2) nonlinearity in tissue fiber tension. One adaptation that would increase fundamental frequency range is greater freedom in joint rotation or gliding of two cartilages (thyroid and cricoid), so that vocal fold length change is maximized. Alternatively, tissue layers can develop to bear a disproportionate fiber tension (i.e., a ligament with high density collagen fibers), increasing the fundamental frequency range and thereby vocal versatility. The range of fundamental frequency across species is thus not simply one-dimensional, but can be conceptualized as the dependent variable in a multi-dimensional morphospace. In humans, this could allow for variations that could be clinically important for voice therapy and vocal fold repair. Alternative solutions could also have importance in vocal training for singing and other highly-skilled vocalizations. PMID:27309543

  14. Fundamental frequency and voice perturbation measures in smokers and non-smokers: An acoustic and perceptual study

    NASA Astrophysics Data System (ADS)

    Freeman, Allison

    This research examined the fundamental frequency and perturbation (jitter % and shimmer %) measures in young adult (20-30 year-old) and middle-aged adult (40-55 year-old) smokers and non-smokers; there were 36 smokers and 36 non-smokers. Acoustic analysis was carried out utilizing one task: production of sustained /a/. These voice samples were analyzed utilizing Multi-Dimensional Voice Program (MDVP) software, which provided values for fundamental frequency, jitter %, and shimmer %.These values were analyzed for trends regarding smoking status, age, and gender. Statistical significance was found regarding the fundamental frequency, jitter %, and shimmer % for smokers as compared to non-smokers; smokers were found to have significantly lower fundamental frequency values, and significantly higher jitter % and shimmer % values. Statistical significance was not found regarding fundamental frequency, jitter %, and shimmer % for age group comparisons. With regard to gender, statistical significance was found regarding fundamental frequency; females were found to have statistically higher fundamental frequencies as compared to males. However, the relationships between gender and jitter % and shimmer % lacked statistical significance. These results indicate that smoking negatively affects voice quality. This study also examined the ability of untrained listeners to identify smokers and non-smokers based on their voices. Results of this voice perception task suggest that listeners are not accurately able to identify smokers and non-smokers, as statistical significance was not reached. However, despite a lack of significance, trends in data suggest that listeners are able to utilize voice quality to identify smokers and non-smokers.

  15. Driving an Active Vibration Balancer to Minimize Vibrations at the Fundamental and Harmonic Frequencies

    NASA Technical Reports Server (NTRS)

    Holliday, Ezekiel S. (Inventor)

    2014-01-01

    Vibrations of a principal machine are reduced at the fundamental and harmonic frequencies by driving the drive motor of an active balancer with balancing signals at the fundamental and selected harmonics. Vibrations are sensed to provide a signal representing the mechanical vibrations. A balancing signal generator for the fundamental and for each selected harmonic processes the sensed vibration signal with adaptive filter algorithms of adaptive filters for each frequency to generate a balancing signal for each frequency. Reference inputs for each frequency are applied to the adaptive filter algorithms of each balancing signal generator at the frequency assigned to the generator. The harmonic balancing signals for all of the frequencies are summed and applied to drive the drive motor. The harmonic balancing signals drive the drive motor with a drive voltage component in opposition to the vibration at each frequency.

  16. Acoustic analysis of speech variables during depression and after improvement.

    PubMed

    Nilsonne, A

    1987-09-01

    Speech recordings were made of 16 depressed patients during depression and after clinical improvement. The recordings were analyzed using a computer program which extracts acoustic parameters from the fundamental frequency contour of the voice. The percent pause time, the standard deviation of the voice fundamental frequency distribution, the standard deviation of the rate of change of the voice fundamental frequency and the average speed of voice change were found to correlate to the clinical state of the patient. The mean fundamental frequency, the total reading time and the average rate of change of the voice fundamental frequency did not differ between the depressed and the improved group. The acoustic measures were more strongly correlated to the clinical state of the patient as measured by global depression scores than to single depressive symptoms such as retardation or agitation.

  17. Individual Differences in the Frequency-Following Response: Relation to Pitch Perception

    PubMed Central

    Coffey, Emily B. J.; Colagrosso, Emilia M. G.; Lehmann, Alexandre; Schönwiesner, Marc; Zatorre, Robert J.

    2016-01-01

    The scalp-recorded frequency-following response (FFR) is a measure of the auditory nervous system’s representation of periodic sound, and may serve as a marker of training-related enhancements, behavioural deficits, and clinical conditions. However, FFRs of healthy normal subjects show considerable variability that remains unexplained. We investigated whether the FFR representation of the frequency content of a complex tone is related to the perception of the pitch of the fundamental frequency. The strength of the fundamental frequency in the FFR of 39 people with normal hearing was assessed when they listened to complex tones that either included or lacked energy at the fundamental frequency. We found that the strength of the fundamental representation of the missing fundamental tone complex correlated significantly with people's general tendency to perceive the pitch of the tone as either matching the frequency of the spectral components that were present, or that of the missing fundamental. Although at a group level the fundamental representation in the FFR did not appear to be affected by the presence or absence of energy at the same frequency in the stimulus, the two conditions were statistically distinguishable for some subjects individually, indicating that the neural representation is not linearly dependent on the stimulus content. In a second experiment using a within-subjects paradigm, we showed that subjects can learn to reversibly select between either fundamental or spectral perception, and that this is accompanied both by changes to the fundamental representation in the FFR and to cortical-based gamma activity. These results suggest that both fundamental and spectral representations coexist, and are available for later auditory processing stages, the requirements of which may also influence their relative strength and thus modulate FFR variability. The data also highlight voluntary mode perception as a new paradigm with which to study top-down vs bottom-up mechanisms that support the emerging view of the FFR as the outcome of integrated processing in the entire auditory system. PMID:27015271

  18. Anharmonic calculations of frequencies and intensities of Osbnd H stretching vibrations of (R)-1,3-butanediol conformers in the fundamentals and first overtones by density functional theory

    NASA Astrophysics Data System (ADS)

    Futami, Yoshisuke; Minamoto, Chihiro; Kudoh, Satoshi

    2018-05-01

    The frequencies and absorption intensities of the five kinds of conformers of 1,3-butanediol with the same carbon skeleton (GG‧) were calculated by anharmonic calculation for the fundamentals and first overtones of OH stretching vibrations. The four kinds of conformers form intramolecular hydrogen bonds and one conformer did not. Intramolecular hydrogen bond formation shifted the frequency of fundamental and first overtone of H-bonding OH stretching vibration to the lower frequency. The absorption intensities of the fundamentals as well as the vibrational anharmonicities increased upon hydrogen bond formation, while the intensities of first overtones decreased. The differences of conformers were clearly seen in the frequencies of the first overtones of free OH.

  19. Influences of Fundamental Frequency, Formant Frequencies, Aperiodicity, and Spectrum Level on the Perception of Voice Gender

    ERIC Educational Resources Information Center

    Skuk, Verena G.; Schweinberger, Stefan R.

    2014-01-01

    Purpose: To determine the relative importance of acoustic parameters (fundamental frequency [F0], formant frequencies [FFs], aperiodicity, and spectrum level [SL]) on voice gender perception, the authors used a novel parameter-morphing approach that, unlike spectral envelope shifting, allows the application of nonuniform scale factors to transform…

  20. 47 CFR 15.33 - Frequency range of radiated measurements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... radiator operates at or above 30 GHz: to the fifth harmonic of the highest fundamental frequency or to 200... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates below 10 GHz: to the tenth harmonic of the highest fundamental frequency or to 40 GHz, whichever is...

  1. Glottal open quotient in singing: Measurements and correlation with laryngeal mechanisms, vocal intensity, and fundamental frequency

    NASA Astrophysics Data System (ADS)

    Henrich, Nathalie; D'Alessandro, Christophe; Doval, Boris; Castellengo, Michèle

    2005-03-01

    This article presents the results of glottal open-quotient measurements in the case of singing voice production. It explores the relationship between open quotient and laryngeal mechanisms, vocal intensity, and fundamental frequency. The audio and electroglottographic signals of 18 classically trained male and female singers were recorded and analyzed with regard to vocal intensity, fundamental frequency, and open quotient. Fundamental frequency and open quotient are derived from the differentiated electroglottographic signal, using the DECOM (DEgg Correlation-based Open quotient Measurement) method. As male and female phonation may differ in respect to vocal-fold vibratory properties, a distinction is made between two different glottal configurations, which are called laryngeal mechanisms: mechanism 1 (related to chest, modal, and male head register) and mechanism 2 (related to falsetto for male and head register for female). The results show that open quotient depends on the laryngeal mechanisms. It ranges from 0.3 to 0.8 in mechanism 1 and from 0.5 to 0.95 in mechanism 2. The open quotient is strongly related to vocal intensity in mechanism 1 and to fundamental frequency in mechanism 2. .

  2. Observations concerning the generation and propagation of Type III solar bursts

    NASA Technical Reports Server (NTRS)

    Kellogg, P. J.

    1986-01-01

    A number of Type III bursts were observed during the Helios missions in which the burst exciter passed over the spacecraft, as evidenced by strong electric field fluctuations near the plasma frequency. Six of these were suitable for detailed study. Of the six events, one was ambiguous, one showed what is interpreted as a switchover from harmonic to fundamental, and the rest all generated fundamental at onset. This would be expected if both fundamental and harmonic are generated, as, at a fixed frequency, the fundamental will be generated earlier. For the event which seems to show both fundamental and harmonic emission, the frequency ratio is not exactly 2. This is explained in terms of a time delay of the fundamental, due to scattering and diffusion in the source region. A time delay of the order of 600 seconds at 1 AU and 20 kHz, and inversely proportional to frequency, is required to explain the observations. Crude estimates show that delay times at least this long may be attributed to trapping and scattering.

  3. Pattern masking: the importance of remote spatial frequencies and their phase alignment.

    PubMed

    Huang, Pi-Chun; Maehara, Goro; May, Keith A; Hess, Robert F

    2012-02-16

    To assess the effects of spatial frequency and phase alignment of mask components in pattern masking, target threshold vs. mask contrast (TvC) functions for a sine-wave grating (S) target were measured for five types of mask: a sine-wave grating (S), a square-wave grating (Q), a missing fundamental square-wave grating (M), harmonic complexes consisting of phase-scrambled harmonics of a square wave (Qp), and harmonic complexes consisting of phase-scrambled harmonics of a missing fundamental square wave (Mp). Target and masks had the same fundamental frequency (0.46 cpd) and the target was added in phase with the fundamental frequency component of the mask. Under monocular viewing conditions, the strength of masking depends on phase relationships among mask spatial frequencies far removed from that of the target, at least 3 times the target frequency, only when there are common target and mask spatial frequencies. Under dichoptic viewing conditions, S and Q masks produced similar masking to each other and the phase-scrambled masks (Qp and Mp) produced less masking. The results suggest that pattern masking is spatial frequency broadband in nature and sensitive to the phase alignments of spatial components.

  4. Multifrequency synthesis and extraction using square wave projection patterns for quantitative tissue imaging.

    PubMed

    Nadeau, Kyle P; Rice, Tyler B; Durkin, Anthony J; Tromberg, Bruce J

    2015-11-01

    We present a method for spatial frequency domain data acquisition utilizing a multifrequency synthesis and extraction (MSE) method and binary square wave projection patterns. By illuminating a sample with square wave patterns, multiple spatial frequency components are simultaneously attenuated and can be extracted to determine optical property and depth information. Additionally, binary patterns are projected faster than sinusoids typically used in spatial frequency domain imaging (SFDI), allowing for short (millisecond or less) camera exposure times, and data acquisition speeds an order of magnitude or more greater than conventional SFDI. In cases where sensitivity to superficial layers or scattering is important, the fundamental component from higher frequency square wave patterns can be used. When probing deeper layers, the fundamental and harmonic components from lower frequency square wave patterns can be used. We compared optical property and depth penetration results extracted using square waves to those obtained using sinusoidal patterns on an in vivo human forearm and absorbing tube phantom, respectively. Absorption and reduced scattering coefficient values agree with conventional SFDI to within 1% using both high frequency (fundamental) and low frequency (fundamental and harmonic) spatial frequencies. Depth penetration reflectance values also agree to within 1% of conventional SFDI.

  5. Multifrequency synthesis and extraction using square wave projection patterns for quantitative tissue imaging

    PubMed Central

    Nadeau, Kyle P.; Rice, Tyler B.; Durkin, Anthony J.; Tromberg, Bruce J.

    2015-01-01

    Abstract. We present a method for spatial frequency domain data acquisition utilizing a multifrequency synthesis and extraction (MSE) method and binary square wave projection patterns. By illuminating a sample with square wave patterns, multiple spatial frequency components are simultaneously attenuated and can be extracted to determine optical property and depth information. Additionally, binary patterns are projected faster than sinusoids typically used in spatial frequency domain imaging (SFDI), allowing for short (millisecond or less) camera exposure times, and data acquisition speeds an order of magnitude or more greater than conventional SFDI. In cases where sensitivity to superficial layers or scattering is important, the fundamental component from higher frequency square wave patterns can be used. When probing deeper layers, the fundamental and harmonic components from lower frequency square wave patterns can be used. We compared optical property and depth penetration results extracted using square waves to those obtained using sinusoidal patterns on an in vivo human forearm and absorbing tube phantom, respectively. Absorption and reduced scattering coefficient values agree with conventional SFDI to within 1% using both high frequency (fundamental) and low frequency (fundamental and harmonic) spatial frequencies. Depth penetration reflectance values also agree to within 1% of conventional SFDI. PMID:26524682

  6. Vowel selection and its effects on perturbation and nonlinear dynamic measures.

    PubMed

    Maccallum, Julia K; Zhang, Yu; Jiang, Jack J

    2011-01-01

    Acoustic analysis of voice is typically conducted on recordings of sustained vowel phonation. This study applied perturbation and nonlinear dynamic analyses to the vowels /a/, /i/, and /u/ in order to determine vowel selection effects on analysis. Forty subjects (20 males and 20 females) with normal voices participated in recording. Traditional parameters of fundamental frequency, signal-to-noise ratio, percent jitter, and percent shimmer were calculated for the signals using CSpeech. Nonlinear dynamic parameters of correlation dimension and second-order entropy were also calculated. Perturbation analysis results were largely incongruous in this study and in previous research. Fundamental frequency results corroborated previous work, indicating higher fundamental frequency for /i/ and /u/ and lower fundamental frequency for /a/. Signal-to-noise ratio results showed that /i/ and /u/ have greater harmonic levels than /a/. Results of nonlinear dynamic analysis suggested that more complex activity may be evident in /a/ than in /i/ or /u/. Percent jitter and percent shimmer may not be useful for description of acoustic differences between vowels. Fundamental frequency, signal-to-noise ratio, and nonlinear dynamic parameters may be applied to characterize /a/ as having lower frequency, higher noise, and greater nonlinear components than /i/ and /u/. Copyright © 2010 S. Karger AG, Basel.

  7. Vocal fundamental and formant frequencies are honest signals of threat potential in peripubertal males.

    PubMed

    Hodges-Simeon, Carolyn R; Gurven, Michael; Puts, David A; Gaulin, Steven J C

    2014-07-01

    Fundamental and formant frequencies influence perceived pitch and are sexually dimorphic in humans. The information content of these acoustic parameters can illuminate the forces of sexual selection shaping vocal sex differences as well as the mechanisms that ensure signal reliability. We use multiple regression to examine the relationships between somatic (height, adiposity, and strength) and acoustic (fundamental frequency [ F 0 ], formant position [ P f ], and fundamental frequency variation [ F 0 -SD]) characteristics in a sample of peripubertal Bolivian Tsimane. Results indicate that among males-but not females-strength is the strongest predictor of F 0 and P f and that F 0 and P f are independent predictors of strength when height and adiposity are controlled. These findings suggest that listeners may attend to vocal frequencies because they signal honest, nonredundant information about male strength and threat potential, which are strongly related to physical maturity and which cannot be ascertained from visual or other indicators of height or adiposity alone.

  8. Fundamentals of Acoustics. Psychoacoustics and Hearing. Acoustical Measurements

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Ahumada, Al (Technical Monitor)

    1997-01-01

    These are 3 chapters that will appear in a book titled "Building Acoustical Design", edited by Charles Salter. They are designed to introduce the reader to fundamental concepts of acoustics, particularly as they relate to the built environment. "Fundamentals of Acoustics" reviews basic concepts of sound waveform frequency, pressure, and phase. "Psychoacoustics and Hearing" discusses the human interpretation sound pressure as loudness, particularly as a function of frequency. "Acoustic Measurements" gives a simple overview of the time and frequency weightings for sound pressure measurements that are used in acoustical work.

  9. Approximate method for calculating free vibrations of a large-wind-turbine tower structure

    NASA Technical Reports Server (NTRS)

    Das, S. C.; Linscott, B. S.

    1977-01-01

    A set of ordinary differential equations were derived for a simplified structural dynamic lumped-mass model of a typical large-wind-turbine tower structure. Dunkerley's equation was used to arrive at a solution for the fundamental natural frequencies of the tower in bending and torsion. The ERDA-NASA 100-kW wind turbine tower structure was modeled, and the fundamental frequencies were determined by the simplified method described. The approximate fundamental natural frequencies for the tower agree within 18 percent with test data and predictions analyzed.

  10. Comparison of fundamental, second harmonic, and superharmonic imaging: a simulation study.

    PubMed

    van Neer, Paul L M J; Danilouchkine, Mikhail G; Verweij, Martin D; Demi, Libertario; Voormolen, Marco M; van der Steen, Anton F W; de Jong, Nico

    2011-11-01

    In medical ultrasound, fundamental imaging (FI) uses the reflected echoes from the same spectral band as that of the emitted pulse. The transmission frequency determines the trade-off between penetration depth and spatial resolution. Tissue harmonic imaging (THI) employs the second harmonic of the emitted frequency band to construct images. Recently, superharmonic imaging (SHI) has been introduced, which uses the third to the fifth (super) harmonics. The harmonic level is determined by two competing phenomena: nonlinear propagation and frequency dependent attenuation. Thus, the transmission frequency yielding the optimal trade-off between the spatial resolution and the penetration depth differs for THI and SHI. This paper quantitatively compares the concepts of fundamental, second harmonic, and superharmonic echocardiography at their optimal transmission frequencies. Forward propagation is modeled using a 3D-KZK implementation and the iterative nonlinear contrast source (INCS) method. Backpropagation is assumed to be linear. Results show that the fundamental lateral beamwidth is the narrowest at focus, while the superharmonic one is narrower outside the focus. The lateral superharmonic roll-off exceeds the fundamental and second harmonic roll-off. Also, the axial resolution of SHI exceeds that of FI and THI. The far-field pulse-echo superharmonic pressure is lower than that of the fundamental and second harmonic. SHI appears suited for echocardiography and is expected to improve its image quality at the cost of a slight reduction in depth-of-field.

  11. The Effect of Communications Medium on the Fundamental Frequency of Speech.

    ERIC Educational Resources Information Center

    Noll, A. Michael

    1978-01-01

    Describes the results of preliminary experiments to investigate the effects of communications medium (face-to-face and two-way closed circuit television) on the fundamental frequency of speakers in a dyadic communications situation. (JMF)

  12. Optimal lay-up design of variable stiffness laminated composite plates by a layer-wise optimization technique

    NASA Astrophysics Data System (ADS)

    Houmat, A.

    2018-02-01

    The optimal lay-up design for the maximum fundamental frequency of variable stiffness laminated composite plates is investigated using a layer-wise optimization technique. The design variables are two fibre orientation angles per ply. Thin plate theory is used in conjunction with a p-element to calculate the fundamental frequencies of symmetrically and antisymmetrically laminated composite plates. Comparisons with existing optimal solutions for constant stiffness symmetrically laminated composite plates show excellent agreement. It is observed that the maximum fundamental frequency can be increased considerably using variable stiffness design as compared to constant stiffness design. In addition, optimal lay-ups for the maximum fundamental frequency of variable stiffness symmetrically and antisymmetrically laminated composite plates with different aspect ratios and various combinations of free, simply supported and clamped edge conditions are presented. These should prove a useful benchmark for optimal lay-ups of variable stiffness laminated composite plates.

  13. Subglottal pressure and fundamental frequency control in contact calls of juvenile Alligator mississippiensis

    PubMed Central

    Riede, Tobias; Tokuda, Isao T.; Farmer, C. G.

    2011-01-01

    SUMMARY Vocalization is rare among non-avian reptiles, with the exception of the crocodilians, the sister taxon of birds. Crocodilians have a complex vocal repertoire. Their vocal and respiratory system is not well understood but appears to consist of a combination of features that are also found in the extremely vocal avian and mammalian taxa. Anatomical studies suggest that the alligator larynx is able to abduct and adduct the vocal folds, but not to elongate or shorten them, and is therefore lacking a key regulator of frequency, yet alligators can modulate fundamental frequency remarkably well. We investigated the morphological and physiological features of sound production in alligators. Vocal fold length scales isometrically across a wide range of alligator body sizes. The relationship between fundamental frequency and subglottal pressure is significant in some individuals at some isolated points, such as call onset and position of maximum fundamental frequency. The relationship is not consistent over large segments of the call. Fundamental frequency can change faster than expected by pressure changes alone, suggesting an active motor pattern controls frequency and is intrinsic to the larynx. We utilized a two-mass vocal fold model to test whether abduction and adduction could generate this motor pattern. The fine-tuned interplay between subglottal pressure and glottal adduction can achieve frequency modulations much larger than those resulting from subglottal pressure variations alone and of similar magnitude, as observed in alligator calls. We conclude that the alligator larynx represents a sound source with only two control parameters (subglottal pressure and vocal fold adduction) in contrast to the mammalian larynx in which three parameters can be altered to modulate frequency (subglottal pressure, vocal fold adduction and length/tension). PMID:21865521

  14. Inversion of high frequency surface waves with fundamental and higher modes

    USGS Publications Warehouse

    Xia, J.; Miller, R.D.; Park, C.B.; Tian, G.

    2003-01-01

    The phase velocity of Rayleigh-waves of a layered earth model is a function of frequency and four groups of earth parameters: compressional (P)-wave velocity, shear (S)-wave velocity, density, and thickness of layers. For the fundamental mode of Rayleigh waves, analysis of the Jacobian matrix for high frequencies (2-40 Hz) provides a measure of dispersion curve sensitivity to earth model parameters. S-wave velocities are the dominant influence of the four earth model parameters. This thesis is true for higher modes of high frequency Rayleigh waves as well. Our numerical modeling by analysis of the Jacobian matrix supports at least two quite exciting higher mode properties. First, for fundamental and higher mode Rayleigh wave data with the same wavelength, higher modes can "see" deeper than the fundamental mode. Second, higher mode data can increase the resolution of the inverted S-wave velocities. Real world examples show that the inversion process can be stabilized and resolution of the S-wave velocity model can be improved when simultaneously inverting the fundamental and higher mode data. ?? 2002 Elsevier Science B.V. All rights reserved.

  15. Nanoscale Subsurface Imaging via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy

    NASA Technical Reports Server (NTRS)

    Cantrell, Sean A.; Cantrell, John H.; Lilehei, Peter T.

    2007-01-01

    A novel scanning probe microscope methodology has been developed that employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by the fundamental resonance frequency of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever fundamental resonance. The resonance-enhanced difference-frequency signals are used to create images of embedded nanoscale features.

  16. Dual-wavelength green laser with a 4.5 THz frequency difference based on self-frequency- doubling in Nd3+ -doped aperiodically poled lithium niobate.

    PubMed

    Maestre, H; Torregrosa, A J; Fernández-Pousa, C R; Rico, M L; Capmany, J

    2008-05-01

    We report a dual-wavelength continuous-wave laser at 542.4 and 546.8 nm based on an Nd(3+)-doped aperiodically poled lithium niobate crystal. Two fundamental infrared (IR) wavelengths at 1084.8 and 1093.6 nm are simultaneously oscillated and self-frequency-doubled to green. The aperiodic domain distribution patterned in the crystal allows for quasi-phase matched self-frequency-doubling of both IR fundamentals while avoiding their sum-frequency mixing.

  17. Spectrum-averaged Harmonic Path (SHAPA) algorithm for non-contact vital sign monitoring with ultra-wideband (UWB) radar.

    PubMed

    Van Nguyen; Javaid, Abdul Q; Weitnauer, Mary Ann

    2014-01-01

    We introduce the Spectrum-averaged Harmonic Path (SHAPA) algorithm for estimation of heart rate (HR) and respiration rate (RR) with Impulse Radio Ultrawideband (IR-UWB) radar. Periodic movement of human torso caused by respiration and heart beat induces fundamental frequencies and their harmonics at the respiration and heart rates. IR-UWB enables capture of these spectral components and frequency domain processing enables a low cost implementation. Most existing methods of identifying the fundamental component either in frequency or time domain to estimate the HR and/or RR lead to significant error if the fundamental is distorted or cancelled by interference. The SHAPA algorithm (1) takes advantage of the HR harmonics, where there is less interference, and (2) exploits the information in previous spectra to achieve more reliable and robust estimation of the fundamental frequency in the spectrum under consideration. Example experimental results for HR estimation demonstrate how our algorithm eliminates errors caused by interference and produces 16% to 60% more valid estimates.

  18. The siren song of vocal fundamental frequency for romantic relationships.

    PubMed

    Weusthoff, Sarah; Baucom, Brian R; Hahlweg, Kurt

    2013-01-01

    A multitude of factors contribute to why and how romantic relationships are formed as well as whether they ultimately succeed or fail. Drawing on evolutionary models of attraction and speech production as well as integrative models of relationship functioning, this review argues that paralinguistic cues (more specifically the fundamental frequency of the voice) that are initially a strong source of attraction also increase couples' risk for relationship failure. Conceptual similarities and differences between the multiple operationalizations and interpretations of vocal fundamental frequency are discussed and guidelines are presented for understanding both convergent and non-convergent findings. Implications for clinical practice and future research are discussed.

  19. Children's Use of the Prosodic Characteristics of Infant-Directed Speech.

    ERIC Educational Resources Information Center

    Weppelman, Tammy L.; Bostow, Angela; Schiffer, Ryan; Elbert-Perez, Evelyn; Newman, Rochelle S.

    2003-01-01

    Examined whether young children (4 years of age) show prosodic changes when speaking to infants. Measured children's word duration in infant-directed speech compared to adult-directed speech, examined amplitude variability, and examined both average fundamental frequency and fundamental frequency standard deviation. Results indicate that…

  20. An acoustical assessment of pitch-matching accuracy in relation to speech frequency, speech frequency range, age and gender in preschool children

    NASA Astrophysics Data System (ADS)

    Trollinger, Valerie L.

    This study investigated the relationship between acoustical measurement of singing accuracy in relationship to speech fundamental frequency, speech fundamental frequency range, age and gender in preschool-aged children. Seventy subjects from Southeastern Pennsylvania; the San Francisco Bay Area, California; and Terre Haute, Indiana, participated in the study. Speech frequency was measured by having the subjects participate in spontaneous and guided speech activities with the researcher, with 18 diverse samples extracted from each subject's recording for acoustical analysis for fundamental frequency in Hz with the CSpeech computer program. The fundamental frequencies were averaged together to derive a mean speech frequency score for each subject. Speech range was calculated by subtracting the lowest fundamental frequency produced from the highest fundamental frequency produced, resulting in a speech range measured in increments of Hz. Singing accuracy was measured by having the subjects each echo-sing six randomized patterns using the pitches Middle C, D, E, F♯, G and A (440), using the solfege syllables of Do and Re, which were recorded by a 5-year-old female model. For each subject, 18 samples of singing were recorded. All samples were analyzed by the CSpeech for fundamental frequency. For each subject, deviation scores in Hz were derived by calculating the difference between what the model sang in Hz and what the subject sang in response in Hz. Individual scores for each child consisted of an overall mean total deviation frequency, mean frequency deviations for each pattern, and mean frequency deviation for each pitch. Pearson correlations, MANOVA and ANOVA analyses, Multiple Regressions and Discriminant Analysis revealed the following findings: (1) moderate but significant (p < .001) relationships emerged between mean speech frequency and the ability to sing the pitches E, F♯, G and A in the study; (2) mean speech frequency also emerged as the strongest predictor of subjects' ability to sing the notes E and F♯; (3) mean speech frequency correlated moderately and significantly (p < .001) with sharpness and flatness of singing response accuracy in Hz; (4) speech range was the strongest predictor of singing accuracy for the pitches G and A in the study (p < .001); (5) gender emerged as a significant, but not the strongest, predictor for ability to sing the pitches in the study above C and D; (6) gender did not correlate with mean speech frequency and speech range; (7) age in months emerged as a low but significant predictor of ability to sing the lower notes (C and D) in the study; (8) age correlated significantly but negatively low (r = -.23, p < .05, two-tailed) with mean speech frequency; and (9) age did not emerge as a significant predictor of overall singing accuracy. Ancillary findings indicated that there were significant differences in singing accuracy based on geographic location by gender, and that siblings and fraternal twins in the study generally performed similarly. In addition, reliability for using the CSpeech for acoustical analysis revealed test/retest correlations of .99, with one exception at .94. Based on these results, suggestions were made concerning future research concerned with studying the use of voice in speech and how it may affect singing development, overall use in singing, and pitch-matching accuracy.

  1. Subglottal pressure, tracheal airflow, and intrinsic laryngeal muscle activity during rat ultrasound vocalization

    PubMed Central

    2011-01-01

    Vocal production requires complex planning and coordination of respiratory, laryngeal, and vocal tract movements, which are incompletely understood in most mammals. Rats produce a variety of whistles in the ultrasonic range that are of communicative relevance and of importance as a model system, but the sources of acoustic variability were mostly unknown. The goal was to identify sources of fundamental frequency variability. Subglottal pressure, tracheal airflow, and electromyographic (EMG) data from two intrinsic laryngeal muscles were measured during 22-kHz and 50-kHz call production in awake, spontaneously behaving adult male rats. During ultrasound vocalization, subglottal pressure ranged between 0.8 and 1.9 kPa. Pressure differences between call types were not significant. The relation between fundamental frequency and subglottal pressure within call types was inconsistent. Experimental manipulations of subglottal pressure had only small effects on fundamental frequency. Tracheal airflow patterns were also inconsistently associated with frequency. Pressure and flow seem to play a small role in regulation of fundamental frequency. Muscle activity, however, is precisely regulated and very sensitive to alterations, presumably because of effects on resonance properties in the vocal tract. EMG activity of cricothyroid and thyroarytenoid muscle was tonic in calls with slow or no fundamental frequency modulations, like 22-kHz and flat 50-kHz calls. Both muscles showed brief high-amplitude, alternating bursts at rates up to 150 Hz during production of frequency-modulated 50-kHz calls. A differentiated and fine regulation of intrinsic laryngeal muscles is critical for normal ultrasound vocalization. Many features of the laryngeal muscle activation pattern during ultrasound vocalization in rats are shared with other mammals. PMID:21832032

  2. Effects of Phonetic Context on Relative Fundamental Frequency

    ERIC Educational Resources Information Center

    Lien, Yu-An S.; Gattuccio, Caitlin I.; Stepp, Cara E.

    2014-01-01

    Purpose: The effect of phonetic context on relative fundamental frequency (RFF) was examined, in order to develop stimuli sets with minimal within-speaker variability that can be implemented in future clinical protocols. Method: Sixteen speakers with healthy voices produced RFF stimuli. Uniform utterances consisted of 3 repetitions of the same…

  3. Cross-Linguistic Differences in Bilinguals' Fundamental Frequency Ranges

    ERIC Educational Resources Information Center

    Ordin, Mikhail; Mennen, Ineke

    2017-01-01

    Purpose: We investigated cross-linguistic differences in fundamental frequency range (FFR) in Welsh-English bilingual speech. This is the first study that reports gender-specific behavior in switching FFRs across languages in bilingual speech. Method: FFR was conceptualized as a behavioral pattern using measures of span (range of fundamental…

  4. Nonexponential London Penetration Depth of FeAs-Based Superconducting RFeAsO[subscript 0.9]F[subscript 0.1] (R=La, Nd) Single Crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, C.; Tillman, M.E.; Kim, H.

    2009-07-31

    The superconducting penetration depth {lambda}(T) has been measured in RFeAsO{sub 0.9}F{sub 0.1} (R=La, Nd) single crystals (R-1111). In Nd-1111, we find an upturn in {lambda}(T) upon cooling and attribute it to the paramagnetism of the Nd ions, similar to the case of the electron-doped cuprate Nd-Ce-Cu-O. After the correction for paramagnetism, the London penetration depth variation is found to follow a power-law behavior, {Delta}{lambda}L(T) {proportional_to} T{sup 2} at low temperatures. The same T{sup 2} variation of {lambda}(T) was found in nonmagnetic La-1111 crystals. Analysis of the superfluid density and of penetration depth anisotropy over the full temperature range is consistentmore » with two-gap superconductivity. Based on this and on our previous work, we conclude that both the RFeAsO (1111) and BaFe{sub 2}As{sub 2} (122) families of pnictide superconductors exhibit unconventional two-gap superconductivity.« less

  5. Characterization of Harmonic Signal Acquisition with Parallel Dipole and Multipole Detectors

    NASA Astrophysics Data System (ADS)

    Park, Sung-Gun; Anderson, Gordon A.; Bruce, James E.

    2018-04-01

    Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is a powerful instrument for the study of complex biological samples due to its high resolution and mass measurement accuracy. However, the relatively long signal acquisition periods needed to achieve high resolution can serve to limit applications of FTICR-MS. The use of multiple pairs of detector electrodes enables detection of harmonic frequencies present at integer multiples of the fundamental cyclotron frequency, and the obtained resolving power for a given acquisition period increases linearly with the order of harmonic signal. However, harmonic signal detection also increases spectral complexity and presents challenges for interpretation. In the present work, ICR cells with independent dipole and harmonic detection electrodes and preamplifiers are demonstrated. A benefit of this approach is the ability to independently acquire fundamental and multiple harmonic signals in parallel using the same ions under identical conditions, enabling direct comparison of achieved performance as parameters are varied. Spectra from harmonic signals showed generally higher resolving power than spectra acquired with fundamental signals and equal signal duration. In addition, the maximum observed signal to noise (S/N) ratio from harmonic signals exceeded that of fundamental signals by 50 to 100%. Finally, parallel detection of fundamental and harmonic signals enables deconvolution of overlapping harmonic signals since observed fundamental frequencies can be used to unambiguously calculate all possible harmonic frequencies. Thus, the present application of parallel fundamental and harmonic signal acquisition offers a general approach to improve utilization of harmonic signals to yield high-resolution spectra with decreased acquisition time. [Figure not available: see fulltext.

  6. Harmonics generation near ion-cyclotron frequency of ECR plasma

    NASA Astrophysics Data System (ADS)

    Chowdhury, Satyajit; Biswas, Subir; Chakrabarti, Nikhil; Pal, Rabindranath

    2017-10-01

    Wave excitation at different frequency regime is employed in the MaPLE device ECR plasma for varied excitation amplitude. At very low amplitude excitation, mainly fundamental frequency mode of the exciter signal frequency comes into play. With the increase in amplitude of applied perturbation, harmonics are generated and dominant over the fundamental frequency mode. There is a fixed critical amplitude of exciter to yield the harmonics and is independent of applied frequency. Observed harmonics and the main frequency mode has propagation characteristics and are discussed here. Exact mode number and propagation nature are also tried to measure in the experiment. Detailed experimental results will be presented. Department of Science and Technology of Government of India (Project No. SB/S2/HEP-005/2014).

  7. Adaptive frequency-domain equalization for the transmission of the fundamental mode in a few-mode fiber.

    PubMed

    Bai, Neng; Xia, Cen; Li, Guifang

    2012-10-08

    We propose and experimentally demonstrate single-carrier adaptive frequency-domain equalization (SC-FDE) to mitigate multipath interference (MPI) for the transmission of the fundamental mode in a few-mode fiber. The FDE approach reduces computational complexity significantly compared to the time-domain equalization (TDE) approach while maintaining the same performance. Both FDE and TDE methods are evaluated by simulating long-haul fundamental-mode transmission using a few-mode fiber. For the fundamental mode operation, the required tap length of the equalizer depends on the differential mode group delay (DMGD) of a single span rather than DMGD of the entire link.

  8. The Impact of Vocal Hyperfunction on Relative Fundamental Frequency during Voicing Offset and Onset

    ERIC Educational Resources Information Center

    Stepp, Cara E.; Hillman, Robert E.; Heaton, James T.

    2010-01-01

    Purpose: This study tested the hypothesis that individuals with vocal hyperfunction would show decreases in relative fundamental frequency (RFF) surrounding a voiceless consonant. Method: This retrospective study of 2 clinical databases used speech samples from 15 control participants and women with hyperfunction-related voice disorders: 82 prior…

  9. Voice Relative Fundamental Frequency via Neck-Skin Acceleration in Individuals with Voice Disorders

    ERIC Educational Resources Information Center

    Lien, Yu-An S.; Calabrese, Carolyn R.; Michener, Carolyn M.; Murray, Elizabeth Heller; Van Stan, Jarrad H.; Mehta, Daryush D.; Hillman, Robert E.; Noordzij, J. Pieter; Stepp, Cara E.

    2015-01-01

    Purpose: This study investigated the use of neck-skin acceleration for relative fundamental frequency (RFF) analysis. Method: Forty individuals with voice disorders associated with vocal hyperfunction and 20 age- and sex-matched control participants were recorded with a subglottal neck-surface accelerometer and a microphone while producing speech…

  10. Effect of Fundamental Frequency on Judgments of Electrolaryngeal Speech

    ERIC Educational Resources Information Center

    Nagle, Kathy F.; Eadie, Tanya L.; Wright, Derek R.; Sumida, Yumi A.

    2012-01-01

    Purpose: To determine (a) the effect of fundamental frequency (f0) on speech intelligibility, acceptability, and perceived gender in electrolaryngeal (EL) speakers, and (b) the effect of known gender on speech acceptability in EL speakers. Method: A 2-part study was conducted. In Part 1, 34 healthy adults provided speech recordings using…

  11. Relative Fundamental Frequency Distinguishes between Phonotraumatic and Non-Phonotraumatic Vocal Hyperfunction

    ERIC Educational Resources Information Center

    Murray, Elizabeth S. Heller; Lien, Yu-An S.; Van Stan, Jarrad H.; Mehta, Daryush D.; Hillman, Robert E.; Noordzij, J. Pieter; Stepp, Cara E.

    2017-01-01

    Purpose: The purpose of this article is to examine the ability of an acoustic measure, relative fundamental frequency (RFF), to distinguish between two subtypes of vocal hyperfunction (VH): phonotraumatic (PVH) and non-phonotraumatic (NPVH). Method: RFF values were compared among control individuals with typical voices (N = 49), individuals with…

  12. 47 CFR 15.245 - Operation within the bands 902-928 MHz, 2435-2465 MHz, 5785-5815 MHz, 10500-10550 MHz, and 24075...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... limited to intentional radiators used as field disturbance sensors, excluding perimeter protection systems. (b) The field strength of emissions from intentional radiators operated within these frequency bands shall comply with the following: Fundamental frequency (MHz) Field strength of fundamental (millivolts...

  13. Gender classification in children based on speech characteristics: using fundamental and formant frequencies of Malay vowels.

    PubMed

    Zourmand, Alireza; Ting, Hua-Nong; Mirhassani, Seyed Mostafa

    2013-03-01

    Speech is one of the prevalent communication mediums for humans. Identifying the gender of a child speaker based on his/her speech is crucial in telecommunication and speech therapy. This article investigates the use of fundamental and formant frequencies from sustained vowel phonation to distinguish the gender of Malay children aged between 7 and 12 years. The Euclidean minimum distance and multilayer perceptron were used to classify the gender of 360 Malay children based on different combinations of fundamental and formant frequencies (F0, F1, F2, and F3). The Euclidean minimum distance with normalized frequency data achieved a classification accuracy of 79.44%, which was higher than that of the nonnormalized frequency data. Age-dependent modeling was used to improve the accuracy of gender classification. The Euclidean distance method obtained 84.17% based on the optimal classification accuracy for all age groups. The accuracy was further increased to 99.81% using multilayer perceptron based on mel-frequency cepstral coefficients. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  14. Freddie Mercury-acoustic analysis of speaking fundamental frequency, vibrato, and subharmonics.

    PubMed

    Herbst, Christian T; Hertegard, Stellan; Zangger-Borch, Daniel; Lindestad, Per-Åke

    2017-04-01

    Freddie Mercury was one of the twentieth century's best-known singers of commercial contemporary music. This study presents an acoustical analysis of his voice production and singing style, based on perceptual and quantitative analysis of publicly available sound recordings. Analysis of six interviews revealed a median speaking fundamental frequency of 117.3 Hz, which is typically found for a baritone voice. Analysis of voice tracks isolated from full band recordings suggested that the singing voice range was 37 semitones within the pitch range of F#2 (about 92.2 Hz) to G5 (about 784 Hz). Evidence for higher phonations up to a fundamental frequency of 1,347 Hz was not deemed reliable. Analysis of 240 sustained notes from 21 a-cappella recordings revealed a surprisingly high mean fundamental frequency modulation rate (vibrato) of 7.0 Hz, reaching the range of vocal tremor. Quantitative analysis utilizing a newly introduced parameter to assess the regularity of vocal vibrato corroborated its perceptually irregular nature, suggesting that vibrato (ir)regularity is a distinctive feature of the singing voice. Imitation of subharmonic phonation samples by a professional rock singer, documented by endoscopic high-speed video at 4,132 frames per second, revealed a 3:1 frequency locked vibratory pattern of vocal folds and ventricular folds.

  15. Piezoelectric Lead Zirconate Titanate (PZT) Ring Shaped Contour-Mode MEMS Resonators

    NASA Astrophysics Data System (ADS)

    Kasambe, P. V.; Asgaonkar, V. V.; Bangera, A. D.; Lokre, A. S.; Rathod, S. S.; Bhoir, D. V.

    2018-02-01

    Flexibility in setting fundamental frequency of resonator independent of its motional resistance is one of the desired criteria in micro-electromechanical (MEMS) resonator design. It is observed that ring-shaped piezoelectric contour-mode MEMS resonators satisfy this design criterion than in case of rectangular plate MEMS resonators. Also ring-shaped contour-mode piezoelectric MEMS resonator has an advantage that its fundamental frequency is defined by in-plane dimensions, but they show variation of fundamental frequency with different Platinum (Pt) thickness referred as change in ratio of fNEW /fO . This paper presents the effects of variation in geometrical parameters and change in piezoelectric material on the resonant frequencies of Platinum piezoelectric-Aluminium ring-shaped contour-mode MEMS resonators and its electrical parameters. The proposed structure with Lead Zirconate Titanate (PZT) as the piezoelectric material was observed to be a piezoelectric material with minimal change in fundamental resonant frequency due to Platinum thickness variation. This structure was also found to exhibit extremely low motional resistance of 0.03 Ω as compared to the 31-35 Ω range obtained when using AlN as the piezoelectric material. CoventorWare 10 is used for the design, simulation and corresponding analysis of resonators which is Finite Element Method (FEM) analysis and design tool for MEMS devices.

  16. Quantification of sound instability in embouchure tremor based on the time-varying fundamental frequency.

    PubMed

    Lee, André; Voget, Jakob; Furuya, Shinichi; Morise, Masanori; Altenmüller, Eckart

    2016-05-01

    Task-specific tremor in musicians is an involuntary oscillating muscular activity mostly of the hand or the embouchure, which predominantly occurs while playing the instrument. In contrast to arm or hand tremors, which have been examined and objectified based on movement kinematics and muscular activity, embouchure tremor has not yet been investigated. To quantify and describe embouchure tremor we analysed sound production and investigated the fluctuation of the time-varying fundamental frequency of sustained notes. A comparison between patients with embouchure tremor and healthy controls showed a significantly higher fluctuation of the fundamental frequency for the patients in the high pitch with a tremor frequency range between 3 and 8 Hz. The present findings firstly provide further information about a scarcely described movement disorder and secondly further evaluate a new quantification method for embouchure tremor, which has recently been established for embouchure dystonia.

  17. An Educational Laboratory Virtual Instrumentation Suite Assisted Experiment for Studying Fundamentals of Series Resistance-Inductance-Capacitance Circuit

    ERIC Educational Resources Information Center

    Rana, K. P. S.; Kumar, Vineet; Mendiratta, Jatin

    2017-01-01

    One of the most elementary concepts in freshmen Electrical Engineering subject comprises the Resistance-Inductance-Capacitance (RLC) circuit fundamentals, that is, their time and frequency domain responses. For a beginner, generally, it is difficult to understand and appreciate the step and the frequency responses, particularly the resonance. This…

  18. Exploring the Clinical Utility of Relative Fundamental Frequency as an Objective Measure of Vocal Hyperfunction

    ERIC Educational Resources Information Center

    Roy, Nelson; Fetrow, Rebecca A.; Merrill, Ray M.; Dromey, Christopher

    2016-01-01

    Purpose: Vocal hyperfunction, related to abnormal laryngeal muscle activity, is considered the proximal cause of primary muscle tension dysphonia (pMTD). Relative fundamental frequency (RFF) has been proposed as an objective acoustic marker of vocal hyperfunction. This study examined (a) the ability of RFF to track changes in vocal hyperfunction…

  19. The Relationship between Relative Fundamental Frequency and a Kinematic Estimate of Laryngeal Stiffness in Healthy Adults

    ERIC Educational Resources Information Center

    McKenna, Victoria S.; Heller Murray, Elizabeth S.; Lien, Yu-An S.; Stepp, Cara E.

    2016-01-01

    Purpose: This study examined the relationship between the acoustic measure relative fundamental frequency (RFF) and a kinematic estimate of laryngeal stiffness. Method: Twelve healthy adults (mean age = 22.7 years, SD = 4.4; 10 women, 2 men) produced repetitions of /ifi/ while varying their vocal effort during simultaneous acoustic and video…

  20. Individual Monitoring of Vocal Effort with Relative Fundamental Frequency: Relationships with Aerodynamics and Listener Perception

    ERIC Educational Resources Information Center

    Lien, Yu-An S.; Michener, Carolyn M.; Eadie, Tanya L.; Stepp, Cara E.

    2015-01-01

    Purpose: The acoustic measure relative fundamental frequency (RFF) was investigated as a potential objective measure to track variations in vocal effort within and across individuals. Method: Twelve speakers with healthy voices created purposeful modulations in their vocal effort during speech tasks. RFF and an aerodynamic measure of vocal effort,…

  1. Effects of Voice Therapy on Relative Fundamental Frequency during Voicing Offset and Onset in Patients with Vocal Hyperfunction

    ERIC Educational Resources Information Center

    Stepp, Cara E.; Merchant, Gabrielle R.; Heaton, James T.; Hillman, Robert E.

    2011-01-01

    Purpose: The purpose of this study was to determine whether the relative fundamental frequency (RFF) surrounding a voiceless consonant in patients with hyperfunctionally related voice disorders would normalize after a successful course of voice therapy. Method: Pre- and posttherapy measurements of RFF were compared in 16 subjects undergoing voice…

  2. Call for papers for special issue of Journal of Molecular Spectroscopy focusing on "Frequency-comb spectroscopy"

    NASA Astrophysics Data System (ADS)

    Foltynowicz, Aleksandra; Picqué, Nathalie; Ye, Jun

    2018-05-01

    Frequency combs are becoming enabling tools for many applications in science and technology, beyond the original purpose of frequency metrology of simple atoms. The precisely evenly spaced narrow lines of a laser frequency comb inspire intriguing approaches to molecular spectroscopy, designed and implemented by a growing community of scientists. Frequency-comb spectroscopy advances the frontiers of molecular physics across the entire electro-magnetic spectrum. Used as frequency rulers, frequency combs enable absolute frequency measurements and precise line shape studies of molecular transitions, for e.g. tests of fundamental physics and improved determination of fundamental constants. As light sources interrogating the molecular samples, they dramatically improve the resolution, precision, sensitivity and acquisition time of broad spectral-bandwidth spectroscopy and open up new opportunities and applications at the leading edge of molecular spectroscopy and sensing.

  3. Maxillary arch dimensions associated with acoustic parameters in prepubertal children.

    PubMed

    Hamdan, Abdul-Latif; Khandakji, Mohannad; Macari, Anthony Tannous

    2018-04-18

    To evaluate the association between maxillary arch dimensions and fundamental frequency and formants of voice in prepubertal subjects. Thirty-five consecutive prepubertal patients seeking orthodontic treatment were recruited (mean age = 11.41 ± 1.46 years; range, 8 to 13.7 years). Participants with a history of respiratory infection, laryngeal manipulation, dysphonia, congenital facial malformations, or history of orthodontic treatment were excluded. Dental measurements included maxillary arch length, perimeter, depth, and width. Voice parameters comprising fundamental frequency (f0_sustained), Habitual pitch (f0_count), Jitter, Shimmer, and different formant frequencies (F1, F2, F3, and F4) were measured using acoustic analysis prior to initiation of any orthodontic treatment. Pearson's correlation coefficients were used to measure the strength of associations between different dental and voice parameters. Multiple linear regressions were computed for the predictions of different dental measurements. Arch width and arch depth had moderate significant negative correlations with f0 ( r = -0.52; P = .001 and r = -0.39; P = .022, respectively) and with habitual frequency ( r = -0.51; P = .0014 and r = -0.34; P = .04, respectively). Arch depth and arch length were significantly correlated with formant F3 and formant F4, respectively. Predictors of arch depth included frequencies of F3 vowels, with a significant regression equation ( P-value < .001; R 2 = 0.49). Similarly, fundamental frequency f0 and frequencies of formant F3 vowels were predictors of arch width, with a significant regression equation ( P-value < .001; R 2 = 0.37). There is a significant association between arch dimensions, particularly arch length and depth, and voice parameters. The formant most predictive of arch depth and width is the third formant, along with fundamental frequency of voice.

  4. The stability of H/V spectral ratios from noise measurements in Armutlu Peninsula (Turkey)

    NASA Astrophysics Data System (ADS)

    Livaoǧlu, Hamdullah; Irmak, T. Serkan; Caka, Deniz; Yavuz, Evrim; Lühr, B. G.; Woith, H.; Tunç, B.; Baris, S.

    2016-04-01

    The horizontal to vertical spectral ratio (H/V) method has been successfully using in order to estimate the fundamental resonance frequency of the sedimentary cover, its thickness and amplification factor since at least 3 decades. There are numerous studies have been carried out on the stability of the H/V spectral ratios. Almost all studies showed that fundamental frequency is stable even measurements are repeated at different times. From this point of view, the results will show us an approach whether the stations are suitable for accurate estimate of earthquake studies and engineering purposes or not. Also we want to see if any effects of the amplification factor changing on the seismograms for Armutlu Seismic Network (ARNET) even though seismic stations are established far away from cultural noise and located on hard rock sites. It has been selected one hour recorded data of all stations during the most stationary times. The amplification and resonant frequency variations of H/V ratio were calculated to investigate temporal stability in time. There is a total harmony in fundamental frequencies values and H/V spectral ratio values in time-lagged periods. Some stations shows secondary minor peaks in high frequency band due to a shallow formation effect or cultural noises around. In the east side of the area ILYS station shows amplitude peak in lower fundamental frequency band from expected. This could compose a high amplification in lower frequencies and so that yield less reliable results in local earthquakes studies. By the experimental results from ambient noise analysis, it could be worked up for relocation of one station.

  5. High-frequency harmonic imaging of the eye.

    PubMed

    Silverman, Ronald H; Coleman, D Jackson; Ketterling, Jeffrey A; Lizzi, Frederic L

    2005-01-01

    PURPOSE: Harmonic imaging has become a well-established technique for ultrasonic imaging at fundamental frequencies of 10 MHz or less. Ophthalmology has benefited from the use of fundamentals of 20 MHz to 50 MHz. Our aim was to explore the ability to generate harmonics for this frequency range, and to generate harmonic images of the eye. METHODS: The presence of harmonics was determined in both water and bovine vitreous propagation media by pulse/echo and hydrophone at a series of increasing excitation pulse intensities and frequencies. Hydrophone measurements were made at the focal point and in the near- and far-fields of 20 MHz and 40 MHz transducers. Harmonic images of the anterior segment of the rabbit eye were obtained by a combination of analog filtering and digital post-processing. RESULTS: Harmonics were generated nearly identically in both water and vitreous. Hydrophone measurements showed the maximum second harmonic to be -5 dB relative to the 35 MHz fundamental at the focus, while in pulse/echo the maximum harmonic amplitude was -15dB relative to the fundamental. Harmonics were absent in the near-field, but present in the far-field. Harmonic images of the eye showed improved resolution. CONCLUSION: Harmonics can be readily generated at very high frequencies, and at power levels compliant with FDA guidelines for ophthalmology. This technique may yield further improvements to the already impressive resolutions obtainable in this frequency range. Improved imaging of the macular region, in particular, may provide significant improvements in diagnosis of retinal disease.

  6. High-frequency harmonic imaging of the eye

    NASA Astrophysics Data System (ADS)

    Silverman, Ronald H.; Coleman, D. Jackson; Ketterling, Jeffrey A.; Lizzi, Frederic L.

    2005-04-01

    Purpose: Harmonic imaging has become a well-established technique for ultrasonic imaging at fundamental frequencies of 10 MHz or less. Ophthalmology has benefited from the use of fundamentals of 20 MHz to 50 MHz. Our aim was to explore the ability to generate harmonics for this frequency range, and to generate harmonic images of the eye. Methods: The presence of harmonics was determined in both water and bovine vitreous propagation media by pulse/echo and hydrophone at a series of increasing excitation pulse intensities and frequencies. Hydrophone measurements were made at the focal point and in the near- and far-fields of 20 MHz and 40 MHz transducers. Harmonic images of the anterior segment of the rabbit eye were obtained by a combination of analog filtering and digital post-processing. Results: Harmonics were generated nearly identically in both water and vitreous. Hydrophone measurements showed the maximum second harmonic to be -5 dB relative to the 35 MHz fundamental at the focus, while in pulse/echo the maximum harmonic amplitude was -15dB relative to the fundamental. Harmonics were absent in the near-field, but present in the far-field. Harmonic images of the eye showed improved resolution. Conclusion: Harmonics can be readily generated at very high frequencies, and at power levels compliant with FDA guidelines for ophthalmology. This technique may yield further improvements to the already impressive resolutions obtainable in this frequency range. Improved imaging of the macular region, in particular, may provide significant improvements in diagnosis of retinal disease.

  7. Voice characteristics in the progression of Parkinson's disease.

    PubMed

    Holmes, R J; Oates, J M; Phyland, D J; Hughes, A J

    2000-01-01

    This study examined the acoustic and perceptual voice characteristics of patients with Parkinson's disease according to disease severity. The perceptual and acoustic voice characteristics of 30 patients with early stage PD and 30 patients with later stage PD were compared with data from 30 normal control subjects. Voice recordings consisted of prolongation of the vowel /a/, scale singing, and a 1-min monologue. In comparison with controls and previously published normative data, both early and later stage PD patients' voices were characterized perceptually by limited pitch and loudness variability, breathiness, harshness and reduced loudness. High modal pitch levels also characterized the voices of males in both early and later stages of PD. Acoustically, the voices of both groups of PD patients demonstrated lower mean intensity levels and reduced maximum phonational frequency ranges in comparison with normative data. Although less clear, the present data also suggested that the PD patients' voices were characterized by excess jitter, a high-speaking fundamental frequency for males and a reduced fundamental frequency variability for females. While several of these voice features did not appear to deteriorate with disease progression (i.e. harshness, high modal pitch and speaking fundamental frequency in males, fundamental frequency variability in females, low intensity and jitter), breathiness, monopitch and monoloudness, low loudness and reduced maximum phonational frequency range were all worse in the later stages of PD. Tremor was the sole voice feature which was associated only with later stage PD.

  8. Contributions of Fundamental Frequency, Formant Spacing, and Glottal Waveform to Talker Identification. Research on Speech Perception. Technical Report No. 5.

    ERIC Educational Resources Information Center

    Carrell, Thomas D.

    This study investigated the contributions of fundamental frequency, formant spacing, and glottal waveform to talker identification. The first two experiments focused on the effect of glottal waveform in the perception of talker identity. Subjects in the first experiment, 30 undergraduate students enrolled in an introductory psychology course,…

  9. Effects of Variability in Fundamental Frequency on L2 Vocabulary Learning: A Comparison between Learners Who Do and Do Not Speak a Tone Language

    ERIC Educational Resources Information Center

    Barcroft, Joe; Sommers, Mitchell S.

    2014-01-01

    Previous studies (Barcroft & Sommers, 2005; Sommers & Barcroft, 2007) have demonstrated that variability in talker, speaking style, and speaking rate positively affect second language vocabulary learning, whereas variability in overall amplitude and fundamental frequency (F0) do not, at least for native English speakers. Sommers and…

  10. Dielectric properties of agricultural products – fundamental principles, influencing factors, and measurement technirques. Chapter 4. Electrotechnologies for Food Processing: Book Series. Volume 3. Radio-Frequency Heating

    USDA-ARS?s Scientific Manuscript database

    In this chapter, definitions of dielectric properties, or permittivity, of materials and a brief discussion of the fundamental principles governing their behavior with respect to influencing factors are presented. The basic physics of the influence of frequency of the electric fields and temperatur...

  11. 47 CFR 15.249 - Operation within the bands 902-928 MHz, 2400-2483.5 MHz, 5725-5875 MHZ, and 24.0-24.25 GHz.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... emissions from intentional radiators operated within these frequency bands shall comply with the following: Fundamental frequency Field strength of fundamental (millivolts/meter) Field strength of harmonics (microvolts..., point-to-point operation as referred to in this paragraph shall be limited to systems employing a fixed...

  12. Methylphenidate mediated change in prosody is specific to the performance of a cognitive task in female adult ADHD patients.

    PubMed

    Bloch, Yuval; Aviram, Shai; Neeman, Ronnie; Braw, Yoram; Nitzan, Uriel; Maoz, Hagai; Mimouni-Bloch, Aviva

    2015-01-01

    Prosody production is highly personalized, related to both the emotional and cognitive state of the speaker and to the task being performed. Fundamental frequency (F main) is a central measurable feature of prosody, associated with having an attention deficit hyperactive disorder (ADHD). Since methylphenidate is an effective therapy for ADHD, we hypothesized that it will affect the fundamental frequency of ADHD patients. The answers of 32 adult ADHD patients were recorded while performing two computerized tasks (cognitive and emotional). Evaluations were performed at baseline and an hour after patients received methylphenidate. A significant effect of methylphenidate was observed on the fundamental frequency, as opposed to other parameters, of prosody. This change was evident while patients performed a cognitive, as opposed to an emotional, task. This change was seen in the 14 female ADHD patients but not in the 18 male ADHD patients. The fundamental frequency while performing a cognitive task without methylphenidate was not different in the female ADHD group, from 22 female controls. This pilot study supports prosodic changes as possible objective and accessible dynamic biological marker of treatment responses specifically in female ADHD.

  13. Achieving Optimal Quantum Acceleration of Frequency Estimation Using Adaptive Coherent Control.

    PubMed

    Naghiloo, M; Jordan, A N; Murch, K W

    2017-11-03

    Precision measurements of frequency are critical to accurate time keeping and are fundamentally limited by quantum measurement uncertainties. While for time-independent quantum Hamiltonians the uncertainty of any parameter scales at best as 1/T, where T is the duration of the experiment, recent theoretical works have predicted that explicitly time-dependent Hamiltonians can yield a 1/T^{2} scaling of the uncertainty for an oscillation frequency. This quantum acceleration in precision requires coherent control, which is generally adaptive. We experimentally realize this quantum improvement in frequency sensitivity with superconducting circuits, using a single transmon qubit. With optimal control pulses, the theoretically ideal frequency precision scaling is reached for times shorter than the decoherence time. This result demonstrates a fundamental quantum advantage for frequency estimation.

  14. Efficient methods for joint estimation of multiple fundamental frequencies in music signals

    NASA Astrophysics Data System (ADS)

    Pertusa, Antonio; Iñesta, José M.

    2012-12-01

    This study presents efficient techniques for multiple fundamental frequency estimation in music signals. The proposed methodology can infer harmonic patterns from a mixture considering interactions with other sources and evaluate them in a joint estimation scheme. For this purpose, a set of fundamental frequency candidates are first selected at each frame, and several hypothetical combinations of them are generated. Combinations are independently evaluated, and the most likely is selected taking into account the intensity and spectral smoothness of its inferred patterns. The method is extended considering adjacent frames in order to smooth the detection in time, and a pitch tracking stage is finally performed to increase the temporal coherence. The proposed algorithms were evaluated in MIREX contests yielding state of the art results with a very low computational burden.

  15. The use of fundamental frequency for lexical segmentation in listeners with cochlear implants.

    PubMed

    Spitzer, Stephanie; Liss, Julie; Spahr, Tony; Dorman, Michael; Lansford, Kaitlin

    2009-06-01

    Fundamental frequency (F0) variation is one of a number of acoustic cues normal hearing listeners use for guiding lexical segmentation of degraded speech. This study examined whether F0 contour facilitates lexical segmentation by listeners fitted with cochlear implants (CIs). Lexical boundary error patterns elicited under unaltered and flattened F0 conditions were compared across three groups: listeners with conventional CI, listeners with CI and preserved low-frequency acoustic hearing, and normal hearing listeners subjected to CI simulations. Results indicate that all groups attended to syllabic stress cues to guide lexical segmentation, and that F0 contours facilitated performance for listeners with low-frequency hearing.

  16. An evaluation of voice stress analysis techniques in a simulated AWACS environment

    NASA Astrophysics Data System (ADS)

    Jones, William A., Jr.

    1990-08-01

    The purpose was to determine if voice analysis algorithms are an effective measure of stress resulting from high workload. Fundamental frequency, frequency jitter, and amplitude shimmer algorithms were employed to measure the effects of stress in crewmember communications data in simulated AWACS mission scenarios. Two independent workload measures were used to identify levels of stress: a predictor model developed by the simulation author based upon scenario generated stimulus events; and the duration of communication for each weapons director, representative of the individual's response to the induced stress. Between eight and eleven speech samples were analyzed for each of the sixteen Air Force officers who participated in the study. Results identified fundamental frequency and frequency jitter as statistically significant vocal indicators of stress, while amplitude shimmer showed no signs of any significant relationship with workload or stress. Consistent with previous research, the frequency algorithm was identified as the most reliable measure. However, the results did not reveal a sensitive discrimination measure between levels of stress, but rather, did distinguish between the presence or absence of stress. The results illustrate a significant relationship between fundamental frequency and the effects of stress and also a significant inverse relationship with jitter, though less dramatic.

  17. The effect of recording and analysis bandwidth on acoustic identification of delphinid species.

    PubMed

    Oswald, Julie N; Rankin, Shannon; Barlow, Jay

    2004-11-01

    Because many cetacean species produce characteristic calls that propagate well under water, acoustic techniques can be used to detect and identify them. The ability to identify cetaceans to species using acoustic methods varies and may be affected by recording and analysis bandwidth. To examine the effect of bandwidth on species identification, whistles were recorded from four delphinid species (Delphinus delphis, Stenella attenuata, S. coeruleoalba, and S. longirostris) in the eastern tropical Pacific ocean. Four spectrograms, each with a different upper frequency limit (20, 24, 30, and 40 kHz), were created for each whistle (n = 484). Eight variables (beginning, ending, minimum, and maximum frequency; duration; number of inflection points; number of steps; and presence/absence of harmonics) were measured from the fundamental frequency of each whistle. The whistle repertoires of all four species contained fundamental frequencies extending above 20 kHz. Overall correct classification using discriminant function analysis ranged from 30% for the 20-kHz upper frequency limit data to 37% for the 40-kHz upper frequency limit data. For the four species included in this study, an upper bandwidth limit of at least 24 kHz is required for an accurate representation of fundamental whistle contours.

  18. A Mechanism for Frequency Modulation in Songbirds Shared with Humans

    PubMed Central

    Margoliash, Daniel

    2013-01-01

    In most animals that vocalize, control of fundamental frequency is a key element for effective communication. In humans, subglottal pressure controls vocal intensity but also influences fundamental frequency during phonation. Given the underlying similarities in the biomechanical mechanisms of vocalization in humans and songbirds, songbirds offer an attractive opportunity to study frequency modulation by pressure. Here, we present a novel technique for dynamic control of subsyringeal pressure in zebra finches. By regulating the opening of a custom-built fast valve connected to the air sac system, we achieved partial or total silencing of specific syllables, and could modify syllabic acoustics through more complex manipulations of air sac pressure. We also observed that more nuanced pressure variations over a limited interval during production of a syllable concomitantly affected the frequency of that syllable segment. These results can be explained in terms of a mathematical model for phonation that incorporates a nonlinear description for the vocal source capable of generating the observed frequency modulations induced by pressure variations. We conclude that the observed interaction between pressure and frequency was a feature of the source, not a result of feedback control. Our results indicate that, beyond regulating phonation or its absence, regulation of pressure is important for control of fundamental frequencies of vocalizations. Thus, although there are separate brainstem pathways for syringeal and respiratory control of song production, both can affect airflow and frequency. We hypothesize that the control of pressure and frequency is combined holistically at higher levels of the vocalization pathways. PMID:23825417

  19. A mechanism for frequency modulation in songbirds shared with humans.

    PubMed

    Amador, Ana; Margoliash, Daniel

    2013-07-03

    In most animals that vocalize, control of fundamental frequency is a key element for effective communication. In humans, subglottal pressure controls vocal intensity but also influences fundamental frequency during phonation. Given the underlying similarities in the biomechanical mechanisms of vocalization in humans and songbirds, songbirds offer an attractive opportunity to study frequency modulation by pressure. Here, we present a novel technique for dynamic control of subsyringeal pressure in zebra finches. By regulating the opening of a custom-built fast valve connected to the air sac system, we achieved partial or total silencing of specific syllables, and could modify syllabic acoustics through more complex manipulations of air sac pressure. We also observed that more nuanced pressure variations over a limited interval during production of a syllable concomitantly affected the frequency of that syllable segment. These results can be explained in terms of a mathematical model for phonation that incorporates a nonlinear description for the vocal source capable of generating the observed frequency modulations induced by pressure variations. We conclude that the observed interaction between pressure and frequency was a feature of the source, not a result of feedback control. Our results indicate that, beyond regulating phonation or its absence, regulation of pressure is important for control of fundamental frequencies of vocalizations. Thus, although there are separate brainstem pathways for syringeal and respiratory control of song production, both can affect airflow and frequency. We hypothesize that the control of pressure and frequency is combined holistically at higher levels of the vocalization pathways.

  20. Centaur feedline dynamics study using power spectral methods. [fundamental mode resonant frequencies of RL-10 oxygen and hydrogen feed lines

    NASA Technical Reports Server (NTRS)

    Lorenzo, C. F.

    1974-01-01

    Tests were conducted to determine the dynamic characteristics of the Centaur/RL-10 oxygen and hydrogen feedlines. The fundamental-mode resonant frequencies were determined by applying power spectral methods to noise-generated data from hot firings of the RL-10 engine. The effect of net positive suction pressure of the main feed pumps on resonant frequency characteristics was determined to be a straight-line relation. Power spectral methods were also used to determine the dynamic characteristics of the boost pumps.

  1. Hyperfine-resolved transition frequency list of fundamental vibration bands of H35Cl and H37Cl

    NASA Astrophysics Data System (ADS)

    Iwakuni, Kana; Sera, Hideyuki; Abe, Masashi; Sasada, Hiroyuki

    2014-12-01

    Sub-Doppler resolution spectroscopy of the fundamental vibration bands of H35Cl and H37Cl has been carried out from 87.1 to 89.9 THz. We have determined the absolute transition frequencies of the hyperfine-resolved R(0) to R(4) transitions with a typical uncertainty of 10 kHz. We have also yielded six molecular constants for each isotopomer in the vibrational excited state, which reproduce the determined frequencies with a standard deviation of about 10 kHz.

  2. [Simulation of speech perception with cochlear implants : Influence of frequency and level of fundamental frequency components with electronic acoustic stimulation].

    PubMed

    Rader, T; Fastl, H; Baumann, U

    2017-03-01

    After implantation of cochlear implants with hearing preservation for combined electronic acoustic stimulation (EAS), the residual acoustic hearing ability relays fundamental speech frequency information in the low frequency range. With the help of acoustic simulation of EAS hearing perception the impact of frequency and level fine structure of speech signals can be systematically examined. The aim of this study was to measure the speech reception threshold (SRT) under various noise conditions with acoustic EAS simulation by variation of the frequency and level information of the fundamental frequency f0 of speech. The study was carried out to determine to what extent the SRT is impaired by modification of the f0 fine structure. Using partial tone time pattern analysis an acoustic EAS simulation of the speech material from the Oldenburg sentence test (OLSA) was generated. In addition, determination of the f0 curve of the speech material was conducted. Subsequently, either the parameter frequency or level of f0 was fixed in order to remove one of the two fine contour information of the speech signal. The processed OLSA sentences were used to determine the SRT in background noise under various test conditions. The conditions "f0 fixed frequency" and "f0 fixed level" were tested under two different situations, under "amplitude modulated background noise" and "continuous background noise" conditions. A total of 24 subjects with normal hearing participated in the study. The SRT in background noise for the condition "f0 fixed frequency" was more favorable in continuous noise with 2.7 dB and in modulated noise with 0.8 dB compared to the condition "f0 fixed level" with 3.7 dB and 2.9 dB, respectively. In the simulation of speech perception with cochlear implants and acoustic components, the level information of the fundamental frequency had a stronger impact on speech intelligibility than the frequency information. The method of simulation of transmission of cochlear implants allows investigation of how various parameters influence speech intelligibility in subjects with normal hearing.

  3. The Influence of Fundamental Frequency and Sound Pressure Level Range on Breathing Patterns in Female Classical Singing

    ERIC Educational Resources Information Center

    Collyer, Sally; Thorpe, C. William; Callaghan, Jean; Davis, Pamela J.

    2008-01-01

    Purpose: This study investigated the influence of fundamental frequency (F0) and sound pressure level (SPL) range on respiratory behavior in classical singing. Method: Five trained female singers performed an 8-s messa di voce (a crescendo and decrescendo on one F0) across their musical F0 range. Lung volume (LV) change was estimated, and…

  4. 47 CFR 15.252 - Operation of wideband vehicular radar systems within the bands 16.2-17.7 GHz and 23.12-29.0 GHz.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... fundamental frequency following the provisions of § 15.31(m). (3) For systems operating in the 23.12-29.0 GHz... with the transmitter operating continuously at a fundamental frequency. The video bandwidth of the... 47 Telecommunication 1 2010-10-01 2010-10-01 false Operation of wideband vehicular radar systems...

  5. Presence of strong harmonics during visual entrainment: a magnetoencephalography study.

    PubMed

    Heinrichs-Graham, Elizabeth; Wilson, Tony W

    2012-09-01

    Visual neurons are known to synchronize their firing with stimuli that flicker at a constant rate (e.g. 12Hz). These so-called visual steady-state responses (VSSR) are a well-studied phenomenon, yet the underlying mechanisms are widely disagreed upon. Furthermore, there is limited evidence that visual neurons may simultaneously synchronize at harmonics of the stimulation frequency. We utilized magnetoencephalography (MEG) to examine synchronization at harmonics of the visual stimulation frequency (18Hz). MEG data were analyzed for event-related-synchronization (ERS) at the fundamental frequency, 36, 54, and 72Hz. We found strong ERS in all bands. Only 31% of participants showed maximum entrainment at the fundamental; others showed stronger entrainment at either 36 or 54Hz. The cortical foci of these responses indicated that the harmonics involved cortices that were partially distinct from the fundamental. These findings suggest that spatially-overlapping subpopulations of neurons are simultaneously entrained at different harmonics of the stimulus frequency. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. The stability of H/V spectral ratios from noise measurements in Armutlu Peninsula (Turkey)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Livaoğlu, Hamdullah, E-mail: hamdullah.livaoglu@kocaeli.edu.tr; Irmak, T. Serkan; Caka, Deniz

    The horizontal to vertical spectral ratio (H/V) method has been successfully using in order to estimate the fundamental resonance frequency of the sedimentary cover, its thickness and amplification factor since at least 3 decades. There are numerous studies have been carried out on the stability of the H/V spectral ratios. Almost all studies showed that fundamental frequency is stable even measurements are repeated at different times. From this point of view, the results will show us an approach whether the stations are suitable for accurate estimate of earthquake studies and engineering purposes or not. Also we want to see ifmore » any effects of the amplification factor changing on the seismograms for Armutlu Seismic Network (ARNET) even though seismic stations are established far away from cultural noise and located on hard rock sites. It has been selected one hour recorded data of all stations during the most stationary times. The amplification and resonant frequency variations of H/V ratio were calculated to investigate temporal stability in time. There is a total harmony in fundamental frequencies values and H/V spectral ratio values in time-lagged periods. Some stations shows secondary minor peaks in high frequency band due to a shallow formation effect or cultural noises around. In the east side of the area ILYS station shows amplitude peak in lower fundamental frequency band from expected. This could compose a high amplification in lower frequencies and so that yield less reliable results in local earthquakes studies. By the experimental results from ambient noise analysis, it could be worked up for relocation of one station.« less

  7. Free vibration analysis of microtubules based on the molecular mechanics and continuum beam theory.

    PubMed

    Zhang, Jin; Wang, Chengyuan

    2016-10-01

    A molecular structural mechanics (MSM) method has been implemented to investigate the free vibration of microtubules (MTs). The emphasis is placed on the effects of the configuration and the imperfect boundaries of MTs. It is shown that the influence of protofilament number on the fundamental frequency is strong, while the effect of helix-start number is almost negligible. The fundamental frequency is also found to decrease as the number of the blocked filaments at boundaries decreases. Subsequently, the Euler-Bernoulli beam theory is employed to reveal the physics behind the simulation results. Fitting the Euler-Bernoulli beam into the MSM data leads to an explicit formula for the fundamental frequency of MTs with various configurations and identifies a possible correlation between the imperfect boundary conditions and the length-dependent bending stiffness of MTs reported in experiments.

  8. [The speaking fundamental frequency and the singing voice type].

    PubMed

    Chernobel'skiĭ, S I

    2010-01-01

    The objective of this study was to determine the speaking fundamental frequency (SFO) in professional opera singers and its dependence on their voice type, if any. A total of 75 persons were available for observation using a special computer clinical program. Male voices were categorized into three groups (viz, tenor, baritone, and bass), female ones into 2 groups (soprano and mezzo-soprano). It was shown that borderlines between SFO types varied within a wide range in all study groups. Significant differences in SFO were documented between tenors, baritones, and basses and between sopranos and mezzo-sopranos; the differences were insignificant between baritones and basses. It is concluded that the speaking fundamental frequency depends on the type of the singing voice; however this characteristic may serve only as an auxiliary tool but can not be used for the classification of singing voices.

  9. Influence of Traffic Vehicles Against Ground Fundamental Frequency Prediction using Ambient Vibration Technique

    NASA Astrophysics Data System (ADS)

    Kamarudin, A. F.; Noh, M. S. Md; Mokhatar, S. N.; Anuar, M. A. Mohd; Ibrahim, A.; Ibrahim, Z.; Daud, M. E.

    2018-04-01

    Ambient vibration (AV) technique is widely used nowadays for ground fundamental frequency prediction. This technique is easy, quick, non-destructive, less operator required and reliable result. The input motions of ambient vibration are originally collected from surrounding natural and artificial excitations. But, careful data acquisition controlled must be implemented to reduce the intrusion of short period noise that could imply the quality of frequency prediction of an investigated site. In this study, investigation on the primary noise intrusion under peak (morning, afternoon and evening) and off peak (early morning) traffic flows (only 8 meter from sensor to road shoulder) against the stability and quality of ground fundamental frequency prediction were carried out. None of specific standard is available for AV data acquisition and processing. Thus, some field and processing parameters recommended by previous studies and guideline were considered. Two units of 1 Hz tri-axial seismometer sensor were closely positioned in front of the main entrance Universiti Tun Hussein Onn Malaysia. 15 minutes of recording length were taken during peak and off peak periods of traffic flows. All passing vehicles were counted and grouped into four classes. Three components of ambient vibration time series recorded in the North-South: NS, East-West: EW and vertical: UD directions were automatically computed into Horizontal to Vertical Spectral Ratio (HVSR), by using open source software of GEOPSY for fundamental ground frequency, Fo determination. Single sharp peak pattern of HVSR curves have been obtained at peak frequencies between 1.33 to 1.38 Hz which classified under soft to dense soil classification. Even identical HVSR curves pattern with close frequencies prediction were obtained under both periods of AV measurement, however the total numbers of stable and quality windows selected for HVSR computation were significantly different but both have satisfied the requirement given by SESAME (2004) guideline. Besides, the second peak frequencies from the early morning HVSR curve was clearly indicated between 8.23 to 8.55 Hz at very low amplitude (Ao < 2), but it should be neglected according to the similar guideline criteria. In conclusion, the ground fundamental frequency using HVSR method was successfully determined by 1 Hz seismometer instrument with recommended to specific parameters consideration on field as well as data processing, without disruption from the nearest traffic excitations.

  10. A Valid Demonstration of the Missing Fundamental Illusion.

    ERIC Educational Resources Information Center

    Larsen, Janet D.; Fritsch, Klaus

    1998-01-01

    Identifies the "missing fundamental illusion" as that which occurs when two tones are heard together and the listener hears a third tone with a pitch corresponding to the difference in their frequencies. Describes an inexpensive and valid demonstration of the missing fundamental using a British police whistle. (MJP)

  11. Fundamentals of Coherent Synchrotron Radiation in Storage Rings

    NASA Astrophysics Data System (ADS)

    Sannibale, F.; Byrd, J. M.; Loftsdottir, A.; Martin, M. C.; Venturini, M.

    2004-05-01

    We present the fundamental concepts for producing stable broadband coherent synchrotron radiation (CSR) in the terahertz frequency region in an electron storage ring. The analysis includes distortion of bunch shape from the synchrotron radiation (SR), enhancing higher frequency coherent emission and limits to stable emission due to a microbunching instability excited by the SR. We use these concepts to optimize the performance of a source for CSR emission.

  12. A two-layer composite model of the vocal fold lamina propria for fundamental frequency regulation.

    PubMed

    Zhang, Kai; Siegmund, Thomas; Chan, Roger W

    2007-08-01

    The mechanical properties of the vocal fold lamina propria, including the vocal fold cover and the vocal ligament, play an important role in regulating the fundamental frequency of human phonation. This study examines the equilibrium hyperelastic tensile deformation behavior of cover and ligament specimens isolated from excised human larynges. Ogden's hyperelastic model is used to characterize the tensile stress-stretch behaviors at equilibrium. Several statistically significant differences in the mechanical response differentiating cover and ligament, as well as gender are found. Fundamental frequencies are predicted from a string model and a beam model, both accounting for the cover and the ligament. The beam model predicts nonzero F(0) for the unstretched state of the vocal fold. It is demonstrated that bending stiffness significantly contributes to the predicted F(0), with the ligament contributing to a higher F(0), especially in females. Despite the availability of only a small data set, the model predicts an age dependence of F(0) in males in agreement with experimental findings. Accounting for two mechanisms of fundamental frequency regulation--vocal fold posturing (stretching) and extended clamping--brings predicted F(0) close to the lower bound of the human phonatory range. Advantages and limitations of the current model are discussed.

  13. A consistent methodology for optimal shape design of graphene sheets to maximize their fundamental frequencies considering topological defects

    NASA Astrophysics Data System (ADS)

    Shi, Jin-Xing; Ohmura, Keiichiro; Shimoda, Masatoshi; Lei, Xiao-Wen

    2018-07-01

    In recent years, shape design of graphene sheets (GSs) by introducing topological defects for enhancing their mechanical behaviors has attracted the attention of scholars. In the present work, we propose a consistent methodology for optimal shape design of GSs using a combination of the molecular mechanics (MM) method, the non-parametric shape optimization method, the phase field crystal (PFC) method, Voronoi tessellation, and molecular dynamics (MD) simulation to maximize their fundamental frequencies. At first, we model GSs as continuum frame models using a link between the MM method and continuum mechanics. Then, we carry out optimal shape design of GSs in fundamental frequency maximization problem based on a developed shape optimization method for frames. However, the obtained optimal shapes of GSs only consisting of hexagonal carbon rings are unstable that do not satisfy the principle of least action, so we relocate carbon atoms on the optimal shapes by introducing topological defects using the PFC method and Voronoi tessellation. At last, we perform the structural relaxation through MD simulation to determine the final optimal shapes of GSs. We design two examples of GSs and the optimal results show that the fundamental frequencies of GSs can be significantly enhanced according to the optimal shape design methodology.

  14. Assessment of foetal exposure to the homogeneous magnetic field harmonic spectrum generated by electricity transmission and distribution networks.

    PubMed

    Fiocchi, Serena; Liorni, Ilaria; Parazzini, Marta; Ravazzani, Paolo

    2015-04-01

    During the last decades studies addressing the effects of exposure to Extremely Low Frequency Electromagnetic Fields (ELF-EMF) have pointed out a possible link between those fields emitted by power lines and childhood leukaemia. They have also stressed the importance of also including in the assessment the contribution of frequency components, namely harmonics, other than the fundamental one. Based on the spectrum of supply voltage networks allowed by the European standard for electricity quality assessment, in this study the exposure of high-resolution three-dimensional models of foetuses to the whole harmonic content of a uniform magnetic field with a fundamental frequency of 50 Hz, was assessed. The results show that the main contribution in terms of induced electric fields to the foetal exposure is given by the fundamental frequency component. The harmonic components add some contributions to the overall level of electric fields, however, due to the extremely low permitted amplitude of the harmonic components with respect to the fundamental, their amplitudes are low. The level of the induced electric field is also much lower than the limits suggested by the guidelines for general public exposure, when the amplitude of the incident magnetic field is set at the maximum permitted level.

  15. Assessment of Foetal Exposure to the Homogeneous Magnetic Field Harmonic Spectrum Generated by Electricity Transmission and Distribution Networks

    PubMed Central

    Fiocchi, Serena; Liorni, Ilaria; Parazzini, Marta; Ravazzani, Paolo

    2015-01-01

    During the last decades studies addressing the effects of exposure to Extremely Low Frequency Electromagnetic Fields (ELF-EMF) have pointed out a possible link between those fields emitted by power lines and childhood leukaemia. They have also stressed the importance of also including in the assessment the contribution of frequency components, namely harmonics, other than the fundamental one. Based on the spectrum of supply voltage networks allowed by the European standard for electricity quality assessment, in this study the exposure of high-resolution three-dimensional models of foetuses to the whole harmonic content of a uniform magnetic field with a fundamental frequency of 50 Hz, was assessed. The results show that the main contribution in terms of induced electric fields to the foetal exposure is given by the fundamental frequency component. The harmonic components add some contributions to the overall level of electric fields, however, due to the extremely low permitted amplitude of the harmonic components with respect to the fundamental, their amplitudes are low. The level of the induced electric field is also much lower than the limits suggested by the guidelines for general public exposure, when the amplitude of the incident magnetic field is set at the maximum permitted level. PMID:25837346

  16. New relationship between fundamental site frequency and thickness of soft sediments from seismic ambient noise

    NASA Astrophysics Data System (ADS)

    Abd el-aal, Abd el-aziz Khairy

    2018-05-01

    In this contribution, new relationship between the fundamental site frequency and the thickness of soft sediments is obtained for many sites in Egypt. The Horizontal-to-Vertical Spectral Ratio ("H/V") technique (known as Nakamura technique) can be used as a robust tool to determine the thickness of soft sediments layers overlaying bedrock from observations and measurements of seismic ambient noise data. In Egypt, numerous seismic ambient noise measurements have been conducted in several areas to determine the dynamic properties of soft soil for engineering purposes. At each site in each studied area, the fundamental site frequency was accurately estimated from the main peak in the spectral ratio between the horizontal and vertical component. Consequently, an extensive database of microtremor measurements, well logging data, and shallow seismic refraction data have been configured and assembled for the studied areas. New formula between fundamental site frequency (f 0 ) and thickness of soft sediments (h) is established. The new formula has been validated and compared with other formulas of earlier scientists, and the results indicate that the calculated depth and geometry of the bedrock surface using new formula are in a good agreement with well logs data and previously published seismic refraction surveys in the investigated sites.

  17. Cross-Linguistic Differences in Bilinguals' Fundamental Frequency Ranges.

    PubMed

    Ordin, Mikhail; Mennen, Ineke

    2017-06-10

    We investigated cross-linguistic differences in fundamental frequency range (FFR) in Welsh-English bilingual speech. This is the first study that reports gender-specific behavior in switching FFRs across languages in bilingual speech. FFR was conceptualized as a behavioral pattern using measures of span (range of fundamental frequency-in semitones-covered by the speaker's voice) and level (overall height of fundamental frequency maxima, minima, and means of speaker's voice) in each language. FFR measures were taken from recordings of 30 Welsh-English bilinguals (14 women and 16 men), who read 70 semantically matched sentences, 35 in each language. Comparisons were made within speakers across languages, separately in male and female speech. Language background and language use information was elicited for qualitative analysis of extralinguistic factors that might affect the FFR. Cross-linguistic differences in FFR were found to be consistent across female bilinguals but random across male bilinguals. Most female bilinguals showed distinct FFRs for each language. Most male bilinguals, however, were found not to change their FFR when switching languages. Those who did change used different strategies than women when differentiating FFRs between languages. Detected cross-linguistic differences in FFR can be explained by sociocultural factors. Therefore, sociolinguistic factors are to be taken into account in any further study of language-specific pitch setting and cross-linguistic differences in FFR.

  18. Assessment of The Stability of The H/v Spectral Ratio of Ambient Noise and Comparison With Earthquake Data In The Cologne Area (germany)

    NASA Astrophysics Data System (ADS)

    Parolai, S.; Richwalski, S. M.; Milkereit, C.; Bormann, P.

    Situated in an active tectonic region the highly industrialised Cologne area (Germany) suffers from moderate sized earthquakes. The mitigation of earthquake risk included a microzonation study with ambient seismic noise and earthquake recordings in two field campaigns. The analysis of the ambient noise data using the horizontal-to-vertical (H/V) spectral ratio allowed for mapping the fundamental resonance frequency of soils in this area. Furthermore, adding independent geological information we calculated new relationships between shear-wave velocity, sediment thickness, and resonance frequency. The stability of the H/V ratio of ambient noise was checked with repeated measurements and the following observations and conclusions can be drawn: (1) The fundamental resonance frequency estimated from the peak in the H/V ratio is stable in time but the amplification factor is not. (2) Therefore, the relative amplification vari- ation in the area should be checked systematically with repeated measurements. (3) The thickness of the sediments is reliably retrieved from the fundamental resonance frequency. The H/V ratio of ambient noise recordings was compared with the H/V ratio of earth- quake recordings as well as with the curves obtained by applying the classical spectral ratio technique (using a reference site). The shapes of the spectral ratios obtained by the different methods are generally in good agreement.In addition, the analysis of earthquake data shows that significant amplifications of the ground motion may also occur at frequencies higher than the fundamental one.

  19. Real time analysis of voiced sounds

    NASA Technical Reports Server (NTRS)

    Hong, J. P. (Inventor)

    1976-01-01

    A power spectrum analysis of the harmonic content of a voiced sound signal is conducted in real time by phase-lock-loop tracking of the fundamental frequency, (f sub 0) of the signal and successive harmonics (h sub 1 through h sub n) of the fundamental frequency. The analysis also includes measuring the quadrature power and phase of each frequency tracked, differentiating the power measurements of the harmonics in adjacent pairs, and analyzing successive differentials to determine peak power points in the power spectrum for display or use in analysis of voiced sound, such as for voice recognition.

  20. Concurrent visual and tactile steady-state evoked potentials index allocation of inter-modal attention: a frequency-tagging study.

    PubMed

    Porcu, Emanuele; Keitel, Christian; Müller, Matthias M

    2013-11-27

    We investigated effects of inter-modal attention on concurrent visual and tactile stimulus processing by means of stimulus-driven oscillatory brain responses, so-called steady-state evoked potentials (SSEPs). To this end, we frequency-tagged a visual (7.5Hz) and a tactile stimulus (20Hz) and participants were cued, on a trial-by-trial basis, to attend to either vision or touch to perform a detection task in the cued modality. SSEPs driven by the stimulation comprised stimulus frequency-following (i.e. fundamental frequency) as well as frequency-doubling (i.e. second harmonic) responses. We observed that inter-modal attention to vision increased amplitude and phase synchrony of the fundamental frequency component of the visual SSEP while the second harmonic component showed an increase in phase synchrony, only. In contrast, inter-modal attention to touch increased SSEP amplitude of the second harmonic but not of the fundamental frequency, while leaving phase synchrony unaffected in both responses. Our results show that inter-modal attention generally influences concurrent stimulus processing in vision and touch, thus, extending earlier audio-visual findings to a visuo-tactile stimulus situation. The pattern of results, however, suggests differences in the neural implementation of inter-modal attentional influences on visual vs. tactile stimulus processing. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Mixing of two co-directional Rayleigh surface waves in a nonlinear elastic material.

    PubMed

    Morlock, Merlin B; Kim, Jin-Yeon; Jacobs, Laurence J; Qu, Jianmin

    2015-01-01

    The mixing of two co-directional, initially monochromatic Rayleigh surface waves in an isotropic, homogeneous, and nonlinear elastic solid is investigated using analytical, finite element method, and experimental approaches. The analytical investigations show that while the horizontal velocity component can form a shock wave, the vertical velocity component can form a pulse independent of the specific ratios of the fundamental frequencies and amplitudes that are mixed. This analytical model is then used to simulate the development of the fundamentals, second harmonics, and the sum and difference frequency components over the propagation distance. The analytical model is further extended to include diffraction effects in the parabolic approximation. Finally, the frequency and amplitude ratios of the fundamentals are identified which provide maximum amplitudes of the second harmonics as well as of the sum and difference frequency components, to help guide effective material characterization; this approach should make it possible to measure the acoustic nonlinearity of a solid not only with the second harmonics, but also with the sum and difference frequency components. Results of the analytical investigations are then confirmed using the finite element method and the experimental feasibility of the proposed technique is validated for an aluminum specimen.

  2. Auditory biological marker of concussion in children

    PubMed Central

    Kraus, Nina; Thompson, Elaine C.; Krizman, Jennifer; Cook, Katherine; White-Schwoch, Travis; LaBella, Cynthia R.

    2016-01-01

    Concussions carry devastating potential for cognitive, neurologic, and socio-emotional disease, but no objective test reliably identifies a concussion and its severity. A variety of neurological insults compromise sound processing, particularly in complex listening environments that place high demands on brain processing. The frequency-following response captures the high computational demands of sound processing with extreme granularity and reliably reveals individual differences. We hypothesize that concussions disrupt these auditory processes, and that the frequency-following response indicates concussion occurrence and severity. Specifically, we hypothesize that concussions disrupt the processing of the fundamental frequency, a key acoustic cue for identifying and tracking sounds and talkers, and, consequently, understanding speech in noise. Here we show that children who sustained a concussion exhibit a signature neural profile. They have worse representation of the fundamental frequency, and smaller and more sluggish neural responses. Neurophysiological responses to the fundamental frequency partially recover to control levels as concussion symptoms abate, suggesting a gain in biological processing following partial recovery. Neural processing of sound correctly identifies 90% of concussion cases and clears 95% of control cases, suggesting this approach has practical potential as a scalable biological marker for sports-related concussion and other types of mild traumatic brain injuries. PMID:28005070

  3. Crystal oscillators using negative voltage gain, single pole response amplifiers

    NASA Technical Reports Server (NTRS)

    Kleinberg, Leonard L. (Inventor)

    1989-01-01

    A simple and inexpensive crystal oscillator is provided which employs negative voltage gain, single pole response amplifiers. The amplifiers may include such configurations as gate inverters, operational amplifiers and conventional bipolar transistor amplifiers, all of which operate at a frequency which is on the roll-off portion of their gain versus frequency curve. Several amplifier feedback circuit variations are employed to set desired bias levels and to allow the oscillator to operate at the crystal's fundamental frequency or at an overtone of the fundamental frequency. The oscillator is made less expensive than comparable oscillators by employing relatively low frequency amplifiers and operating them at roll-off, at frequencies beyond which they are customarily used. Simplicity is provided because operation at roll-off eliminates components ordinarily required in similar circuits to provide sufficient phase-shift in the feedback circuitry for oscillation to occur.

  4. Nonlinear Optical Effects in Liquid Crystals.

    DTIC Science & Technology

    1980-12-10

    susceptibilities Lasers , Nematic, Cholesteric, Flexoelectric, Second-harmonic generation 20M AV*--YRAc rR-r, m, revere i It nf le4U7 siad Idsiully byr...samples are irradiated with laser beam at the fundamental frequency. The laser used in a Q-switched Nd-YAG laser . Sample alignment is achieved either...irradiated with laser beam at the fundamental frequency. The laser used is a Q-switched Nd-YAG laser . Sample alignment is achieved either with rubbing

  5. Protonated Nitrous Oxide, NNOH(+): Fundamental Vibrational Frequencies and Spectroscopic Constants from Quartic Force Fields

    NASA Technical Reports Server (NTRS)

    Huang, Xinchuan; Fortenberry, Ryan C.; Lee, Timothy J.

    2013-01-01

    The interstellar presence of protonated nitrous oxide has been suspected for some time. Using established high-accuracy quantum chemical techniques, spectroscopic constants and fundamental vibrational frequencies are provided for the lower energy O-protonated isomer of this cation and its deuterated isotopologue. The vibrationally-averaged B0 and C0 rotational constants are within 6 MHz of their experimental values and the D(subJ) quartic distortion constants agree with experiment to within 3%. The known gas phase O-H stretch of NNOH(+) is 3330.91 cm(exp-1), and the vibrational configuration interaction computed result is 3330.9 cm(exp-1). Other spectroscopic constants are also provided, as are the rest of the fundamental vibrational frequencies for NNOH(+) and its deuterated isotopologue. This high-accuracy data should serve to better inform future observational or experimental studies of the rovibrational bands of protonated nitrous oxide in the ISM and the laboratory.

  6. Monaural Sound Localization Based on Structure-Induced Acoustic Resonance

    PubMed Central

    Kim, Keonwook; Kim, Youngwoong

    2015-01-01

    A physical structure such as a cylindrical pipe controls the propagated sound spectrum in a predictable way that can be used to localize the sound source. This paper designs a monaural sound localization system based on multiple pyramidal horns around a single microphone. The acoustic resonance within the horn provides a periodicity in the spectral domain known as the fundamental frequency which is inversely proportional to the radial horn length. Once the system accurately estimates the fundamental frequency, the horn length and corresponding angle can be derived by the relationship. The modified Cepstrum algorithm is employed to evaluate the fundamental frequency. In an anechoic chamber, localization experiments over azimuthal configuration show that up to 61% of the proper signal is recognized correctly with 30% misfire. With a speculated detection threshold, the system estimates direction 52% in positive-to-positive and 34% in negative-to-positive decision rate, on average. PMID:25668214

  7. A wearable multichannel tactile display of voice fundamental frequency.

    PubMed

    Yeung, E; Boothroyd, A; Redmond, C

    1988-12-01

    This paper describes a wearable sensory aid that provides the deaf with tactually encoded information about intonation. Fundamental frequency is represented as both place and rate of vibration in a linear array of solenoids. Pitch extraction is accomplished through low-pass filtering and peak detection. A microcomputer is used to measure pitch period, which in turn determines which of the solenoids is actuated. By comparing consecutive periods, the system discriminates against random, noise-related inputs. The device is switchable between 1-, 8-, and 16-channel operation. The electronics package is contained in a case that may be worn on a belt. The solenoid array is worn on the forearm. The system is powered by five, rechargeable lithium cells and runs for at least 6 hours between charges. Proposed developments include the incorporation of digital pitch extraction methods and the option to use the spatial output dimension to encode speech parameters other than fundamental frequency.

  8. Observation of sum-frequency-generation-induced cascaded four-wave mixing using two crossing femtosecond laser pulses in a 0.1 mm beta-barium-borate crystal.

    PubMed

    Liu, Weimin; Zhu, Liangdong; Fang, Chong

    2012-09-15

    We demonstrate the simultaneous generation of multicolor femtosecond laser pulses spanning the wavelength range from UV to near IR in a 0.1 mm Type I beta-barium borate crystal from 800 nm fundamental and weak IR super-continuum white light (SCWL) pulses. The multicolor broadband laser pulses observed are attributed to two concomitant cascaded four-wave mixing (CFWM) processes as corroborated by calculation: (1) directly from the two incident laser pulses; (2) by the sum-frequency generation (SFG) induced CFWM process (SFGFWM). The latter signal arises from the interaction between the frequency-doubled fundamental pulse (400 nm) and the SFG pulse generated in between the fundamental and IR-SCWL pulses. The versatility and simplicity of this spatially dispersed multicolor self-compressed laser pulse generation offer compact and attractive methods to conduct femtosecond stimulated Raman spectroscopy and time-resolved multicolor spectroscopy.

  9. Frequency and zero-point vibrational energy scale factors for double-hybrid density functionals (and other selected methods): can anharmonic force fields be avoided?

    PubMed

    Kesharwani, Manoj K; Brauer, Brina; Martin, Jan M L

    2015-03-05

    We have obtained uniform frequency scaling factors λ(harm) (for harmonic frequencies), λ(fund) (for fundamentals), and λ(ZPVE) (for zero-point vibrational energies (ZPVEs)) for the Weigend-Ahlrichs and other selected basis sets for MP2, SCS-MP2, and a variety of DFT functionals including double hybrids. For selected levels of theory, we have also obtained scaling factors for true anharmonic fundamentals and ZPVEs obtained from quartic force fields. For harmonic frequencies, the double hybrids B2PLYP, B2GP-PLYP, and DSD-PBEP86 clearly yield the best performance at RMSD = 10-12 cm(-1) for def2-TZVP and larger basis sets, compared to 5 cm(-1) at the CCSD(T) basis set limit. For ZPVEs, again, the double hybrids are the best performers, reaching root-mean-square deviations (RMSDs) as low as 0.05 kcal/mol, but even mainstream functionals like B3LYP can get down to 0.10 kcal/mol. Explicitly anharmonic ZPVEs only are marginally more accurate. For fundamentals, however, simple uniform scaling is clearly inadequate.

  10. Joint inversion of high-frequency surface waves with fundamental and higher modes

    USGS Publications Warehouse

    Luo, Y.; Xia, J.; Liu, J.; Liu, Q.; Xu, S.

    2007-01-01

    Joint inversion of multimode surface waves for estimating the shear (S)-wave velocity has received much attention in recent years. In this paper, we first analyze sensitivity of phase velocities of multimodes of surface waves for a six-layer earth model, and then we invert surface-wave dispersion curves of the theoretical model and a real-world example. Sensitivity analysis shows that fundamental mode data are more sensitive to the S-wave velocities of shallow layers and are concentrated on a very narrow frequency band, while higher mode data are more sensitive to the parameters of relatively deeper layers and are distributed over a wider frequency band. These properties provide a foundation of using a multimode joint inversion to define S-wave velocities. Inversion results of both synthetic data and a real-world example demonstrate that joint inversion with the damped least-square method and the singular-value decomposition technique to invert high-frequency surface waves with fundamental and higher mode data simultaneously can effectively reduce the ambiguity and improve the accuracy of S-wave velocities. ?? 2007.

  11. Modeling and Frequency Tracking of Marine Mammal Whistle Calls

    DTIC Science & Technology

    2009-02-01

    retrieve em- bedded information from watermarked synthetic whistle calls. Different fundamental frequency watermarking schemes are proposed b&𔃽ed on...unmodified frequency contour is relatively constant, there is little frequency separation between information bits, and watermark retrieval requires...UHYLHZLQJWKHFROOHFWLRQRILQIRUPDWLRQ6HQGFRPPHQWVUHJDUGLQJWKLVEXUGHQHVWLPDWH RU DQ\\RWKHUDVSHFWRIWKLVFROOHFWLRQ RI LQIRUPDWLRQ LQFOXGLQJ

  12. Stereotypic Laryngeal and Respiratory Motor Patterns Generate Different Call Types in Rat Ultrasound Vocalization

    PubMed Central

    RIEDE, TOBIAS

    2014-01-01

    Rodents produce highly variable ultrasound whistles as communication signals unlike many other mammals, who employ flow-induced vocal fold oscillations to produce sound. The role of larynx muscles in controlling sound features across different call types in ultrasound vocalization (USV) was investigated using laryngeal muscle electromyographic (EMG) activity, subglottal pressure measurements and vocal sound output in awake and spontaneously behaving Sprague–Dawley rats. Results support the hypothesis that glottal shape determines fundamental frequency. EMG activities of thyroarytenoid and cricothyroid muscles were aligned with call duration. EMG intensity increased with fundamental frequency. Phasic activities of both muscles were aligned with fast changing fundamental frequency contours, for example in trills. Activities of the sternothyroid and sternohyoid muscles, two muscles involved in vocal production in other mammals, are not critical for the production of rat USV. To test how stereotypic laryngeal and respiratory activity are across call types and individuals, sets of ten EMG and subglottal pressure parameters were measured in six different call types from six rats. Using discriminant function analysis, on average 80% of parameter sets were correctly assigned to their respective call type. This was significantly higher than the chance level. Since fundamental frequency features of USV are tightly associated with stereotypic activity of intrinsic laryngeal muscles and muscles contributing to build-up of subglottal pressure, USV provide insight into the neurophysiological control of peripheral vocal motor patterns. PMID:23423862

  13. a Comparative Analysis of Fluent and Cerebral Palsied Speech.

    NASA Astrophysics Data System (ADS)

    van Doorn, Janis Lee

    Several features of the acoustic waveforms of fluent and cerebral palsied speech were compared, using six fluent and seven cerebral palsied subjects, with a major emphasis being placed on an investigation of the trajectories of the first three formants (vocal tract resonances). To provide an overall picture which included other acoustic features, fundamental frequency, intensity, speech timing (speech rate and syllable duration), and prevocalization (vocalization prior to initial stop consonants found in cerebral palsied speech) were also investigated. Measurements were made using repetitions of a test sentence which was chosen because it required large excursions of the speech articulators (lips, tongue and jaw), so that differences in the formant trajectories for the fluent and cerebral palsied speakers would be emphasized. The acoustic features were all extracted from the digitized speech waveform (10 kHz sampling rate): the fundamental frequency contours were derived manually, the intensity contours were measured using the signal covariance, speech rate and syllable durations were measured manually, as were the prevocalization durations, while the formant trajectories were derived from short time spectra which were calculated for each 10 ms of speech using linear prediction analysis. Differences which were found in the acoustic features can be summarized as follows. For cerebral palsied speakers, the fundamental frequency contours generally showed inappropriate exaggerated fluctuations, as did some of the intensity contours; the mean fundamental frequencies were either higher or the same as for the fluent subjects; speech rates were reduced, and syllable durations were longer; prevocalization was consistently present at the beginning of the test sentence; formant trajectories were found to have overall reduced frequency ranges, and to contain anomalous transitional features, but it is noteworthy that for any one cerebral palsied subject, the inappropriate trajectory pattern was generally reproducible. The anomalous transitional features took the form of (a) inappropriate transition patterns, (b) reduced frequency excursions, (c) increased transition durations, and (d) decreased maximum rates of frequency change.

  14. 2 + 1 dimensional de Sitter universe emerging from the gauge structure of a nonlinear quantum system.

    PubMed

    Kam, Chon-Fai; Liu, Ren-Bao

    2017-08-29

    Berry phases and gauge structures are fundamental quantum phenomena. In linear quantum mechanics the gauge field in parameter space presents monopole singularities where the energy levels become degenerate. In nonlinear quantum mechanics, which is an effective theory of interacting quantum systems, there can be phase transitions and hence critical surfaces in the parameter space. We find that these critical surfaces result in a new type of gauge field singularity, namely, a conic singularity that resembles the big bang of a 2 + 1 dimensional de Sitter universe, with the fundamental frequency of Bogoliubov excitations acting as the cosmic scale, and mode softening at the critical surface, where the fundamental frequency vanishes, causing a causal singularity. Such conic singularity may be observed in various systems such as Bose-Einstein condensates and molecular magnets. This finding offers a new approach to quantum simulation of fundamental physics.

  15. Three-month-old human infants use vocal cues of body size.

    PubMed

    Pietraszewski, David; Wertz, Annie E; Bryant, Gregory A; Wynn, Karen

    2017-06-14

    Differences in vocal fundamental ( F 0 ) and average formant ( F n ) frequencies covary with body size in most terrestrial mammals, such that larger organisms tend to produce lower frequency sounds than smaller organisms, both between species and also across different sex and life-stage morphs within species. Here we examined whether three-month-old human infants are sensitive to the relationship between body size and sound frequencies. Using a violation-of-expectation paradigm, we found that infants looked longer at stimuli inconsistent with the relationship-that is, a smaller organism producing lower frequency sounds, and a larger organism producing higher frequency sounds-than at stimuli that were consistent with it. This effect was stronger for fundamental frequency than it was for average formant frequency. These results suggest that by three months of age, human infants are already sensitive to the biologically relevant covariation between vocalization frequencies and visual cues to body size. This ability may be a consequence of developmental adaptations for building a phenotype capable of identifying and representing an organism's size, sex and life-stage. © 2017 The Author(s).

  16. Tidal frequency estimation for closed basins

    NASA Technical Reports Server (NTRS)

    Eades, J. B., Jr.

    1978-01-01

    A method was developed for determining the fundamental tidal frequencies for closed basins of water, by means of an eigenvalue analysis. The mathematical model employed, was the Laplace tidal equations.

  17. Frequency characteristics of standing-wave acoustooptic modulators

    NASA Astrophysics Data System (ADS)

    Apolonskii, A. A.; Shchebetov, S. D.

    1991-10-01

    Experimental data are presented on the performance of wide-aperture standing-wave acoustooptic modulators used as laser mode lockers. In particular, attention is given to the acoustooptic and electrical frequency characteristics of the modulators. The existence of a large effective diffraction frequency region below the fundamental frequency is demonstrated. Individual frequency regions of effective diffraction do not correspond to the even and odd harmonics.

  18. [Influence of human personal features on acoustic correlates of speech emotional intonation characteristics].

    PubMed

    Dmitrieva, E S; Gel'man, V Ia; Zaĭtseva, K A; Orlov, A M

    2009-01-01

    Comparative study of acoustic correlates of emotional intonation was conducted on two types of speech material: sensible speech utterances and short meaningless words. The corpus of speech signals of different emotional intonations (happy, angry, frightened, sad and neutral) was created using the actor's method of simulation of emotions. Native Russian 20-70-year-old speakers (both professional actors and non-actors) participated in the study. In the corpus, the following characteristics were analyzed: mean values and standard deviations of the power, fundamental frequency, frequencies of the first and second formants, and utterance duration. Comparison of each emotional intonation with "neutral" utterances showed the greatest deviations of the fundamental frequency and frequencies of the first formant. The direction of these deviations was independent of the semantic content of speech utterance and its duration, age, gender, and being actor or non-actor, though the personal features of the speakers affected the absolute values of these frequencies.

  19. Experimenting with musical intervals

    NASA Astrophysics Data System (ADS)

    Lo Presto, Michael C.

    2003-07-01

    When two tuning forks of different frequency are sounded simultaneously the result is a complex wave with a repetition frequency that is the fundamental of the harmonic series to which both frequencies belong. The ear perceives this 'musical interval' as a single musical pitch with a sound quality produced by the harmonic spectrum responsible for the waveform. This waveform can be captured and displayed with data collection hardware and software. The fundamental frequency can then be calculated and compared with what would be expected from the frequencies of the tuning forks. Also, graphing software can be used to determine equations for the waveforms and predict their shapes. This experiment could be used in an introductory physics or musical acoustics course as a practical lesson in superposition of waves, basic Fourier series and the relationship between some of the ear's subjective perceptions of sound and the physical properties of the waves that cause them.

  20. An Assessment of the State-of-the-Art in Multidisciplinary Aeromechanical Analyses

    DTIC Science & Technology

    2008-01-01

    monolithic formulations. In summary, for aerospace structures, partitioned formulations provide fundamental advantages over fully coupled ones, in addition...important frequencies of local analysis directly to global analysis using detailed modeling. Performed ju- diciously, based on a fundamental understanding of...in 2000 has com- prehensively described the problem, and reviewed the status of fundamental understanding, experimental data, and analytical

  1. An examination of the spectral class low frequency limit for helicopters

    DOT National Transportation Integrated Search

    2011-01-01

    Currently, INM and AEDT do not use spectral data below 50 Hz in their noise computations. However, helicopter rotor rotational noise is dominant below 50Hz, with a fundamental frequency at the blade-pass frequency (BPF) and harmonics at integer multi...

  2. Tracking Helicopters with a Seismic Array

    NASA Astrophysics Data System (ADS)

    Eibl, Eva P. S.; Lokmer, Ivan; Bean, Christopher J.; Akerlie, Eggert

    2015-04-01

    We observed that the pressure or acoustic wave created by the rotor blades of a helicopter can couple to the ground even at 30 km distance where it creates a signal strong enough to be detected by a seismometer. The signal is harmonic tremor with a fundamental frequency downgliding with the inflection point at e.g. 14 Hz and two equally spaced overtones up to the Nyquist frequency of 50 Hz. No difference in the amplitudes between the fundamental frequency and higher harmonics was observed. Such a signature is a consequence of the regularly repeating pressure pulses generated by the helicopter's rotor blades. The signal was recorded by a seven station broadband array with an aperture of 1.6 km. Our spacing is close enough to record the signal at all stations and far enough to observe traveltime differences. The separation of the spectral lines corresponds to the time interval between the repeating sources. The highlighted harmonics contain information about the spectral content of the single source as our signal corresponds to the convolution of an infinite comb function and a single pulse. As we see all harmonics and they have the same amplitude up to the Nyquist frequency we can deduce that the frequency content of the single pulse is flat i.e. it is effectively a delta function up to the Nyquist frequency. We perform a detailed spectral and location analysis of the signal, and compare our results with the known information on the helicopter's speed, location, the frequency of the blades rotation and the amount of blades. This analysis is based on the characteristic shape of the curve i.e. speed of the gliding, minimum and maximum fundamental frequency, amplitudes at the inflection points at different stations and traveltimes deduced from the inflection points at different stations. This observation has an educative value, because the same principle could be used for the analysis of the volcanic harmonic tremor. Harmonic volcanic tremor usually has fundamental frequencies below 10 Hz but frequency downgliding and upgliding up to 30 Hz was observed e.g. on Redoubt volcano. Due to the characteristic shape of the helicopter signal it is nevertheless rather unlikely that this signal is mistaken for volcanic tremor. The helicopter gives us a robust way of testing the method and possible application of the method to volcanic harmonic tremor.

  3. Fundamental (f) oscillations in a magnetically coupled solar interior-atmosphere system - An analytical approach

    NASA Astrophysics Data System (ADS)

    Pintér, Balázs; Erdélyi, R.

    2018-01-01

    Solar fundamental (f) acoustic mode oscillations are investigated analytically in a magnetohydrodynamic (MHD) model. The model consists of three layers in planar geometry, representing the solar interior, the magnetic atmosphere, and a transitional layer sandwiched between them. Since we focus on the fundamental mode here, we assume the plasma is incompressible. A horizontal, canopy-like, magnetic field is introduced to the atmosphere, in which degenerated slow MHD waves can exist. The global (f-mode) oscillations can couple to local atmospheric Alfvén waves, resulting, e.g., in a frequency shift of the oscillations. The dispersion relation of the global oscillation mode is derived, and is solved analytically for the thin-transitional layer approximation and for the weak-field approximation. Analytical formulae are also provided for the frequency shifts due to the presence of a thin transitional layer and a weak atmospheric magnetic field. The analytical results generally indicate that, compared to the fundamental value (ω =√{ gk }), the mode frequency is reduced by the presence of an atmosphere by a few per cent. A thin transitional layer reduces the eigen-frequencies further by about an additional hundred microhertz. Finally, a weak atmospheric magnetic field can slightly, by a few percent, increase the frequency of the eigen-mode. Stronger magnetic fields, however, can increase the f-mode frequency by even up to ten per cent, which cannot be seen in observed data. The presence of a magnetic atmosphere in the three-layer model also introduces non-permitted propagation windows in the frequency spectrum; here, f-mode oscillations cannot exist with certain values of the harmonic degree. The eigen-frequencies can be sensitive to the background physical parameters, such as an atmospheric density scale-height or the rate of the plasma density drop at the photosphere. Such information, if ever observed with high-resolution instrumentation and inverted, could help to gain further insight into solar magnetic structures by means of solar magneto-seismology, and could provide further insight into the role of magnetism in solar oscillations.

  4. Improving Understanding of Emotional Speech Acoustic Content

    NASA Astrophysics Data System (ADS)

    Tinnemore, Anna

    Children with cochlear implants show deficits in identifying emotional intent of utterances without facial or body language cues. A known limitation to cochlear implants is the inability to accurately portray the fundamental frequency contour of speech which carries the majority of information needed to identify emotional intent. Without reliable access to the fundamental frequency, other methods of identifying vocal emotion, if identifiable, could be used to guide therapies for training children with cochlear implants to better identify vocal emotion. The current study analyzed recordings of adults speaking neutral sentences with a set array of emotions in a child-directed and adult-directed manner. The goal was to identify acoustic cues that contribute to emotion identification that may be enhanced in child-directed speech, but are also present in adult-directed speech. Results of this study showed that there were significant differences in the variation of the fundamental frequency, the variation of intensity, and the rate of speech among emotions and between intended audiences.

  5. Glottal flow through a two-mass model: comparison of Navier-Stokes solutions with simplified models.

    PubMed

    de Vries, M P; Schutte, H K; Veldman, A E P; Verkerke, G J

    2002-04-01

    A new numerical model of the vocal folds is presented based on the well-known two-mass models of the vocal folds. The two-mass model is coupled to a model of glottal airflow based on the incompressible Navier-Stokes equations. Glottal waves are produced using different initial glottal gaps and different subglottal pressures. Fundamental frequency, glottal peak flow, and closed phase of the glottal waves have been compared with values known from the literature. The phonation threshold pressure was determined for different initial glottal gaps. The phonation threshold pressure obtained using the flow model with Navier-Stokes equations corresponds better to values determined in normal phonation than the phonation threshold pressure obtained using the flow model based on the Bernoulli equation. Using the Navier-Stokes equations, an increase of the subglottal pressure causes the fundamental frequency and the glottal peak flow to increase, whereas the fundamental frequency in the Bernoulli-based model does not change with increasing pressure.

  6. Method and device for identifying different species of honeybees

    DOEpatents

    Kerr, Howard T.; Buchanan, Michael E.; Valentine, Kenneth H.

    1989-01-01

    A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known fundamental wingbeat frequencies unique to the acoustical signatures of these species as an indication of the identity of the species and indicate the species identity on a readout device.

  7. The effects of a song-singing programme on the affective speaking intonation of people with traumatic brain injury.

    PubMed

    Baker, F; Wigram, T; Gold, C

    2005-07-01

    To examine changes in the relationship between intonation, voice range and mood following music therapy programmes in people with traumatic brain injury. Data from four case studies were pooled and effect size, ANOVA and correlation calculations were performed to evaluate the effectiveness of treatment. Subjects sang three self-selected songs for 15 sessions. Speaking fundamental frequency, fundamental frequency variability, slope, voice range and mood were analysed pre- and post-session. Immediate treatment effects were not found. Long-term improvements in affective intonation were found in three subjects, especially in fundamental frequency. Voice range improved over time and was positively correlated with the three intonation components. Mood scale data showed that immediate effects were in the negative direction whereas there weres increases in positive mood state in the longer-term. Findings suggest that, in the long-term, song singing can improve vocal range and mood and enhance the affective intonation styles of people with TBI.

  8. A case study of alternative site response explanatory variables in Parkfield, California

    USGS Publications Warehouse

    Thompson, E.M.; Baise, L.G.; Kayen, R.E.; Morgan, E.C.; Kaklamanos, J.

    2011-01-01

    The combination of densely-spaced strong-motion stations in Parkfield, California, and spectral analysis of surface waves (SASW) profiles provides an ideal dataset for assessing the accuracy of different site response explanatory variables. We judge accuracy in terms of spatial coverage and correlation with observations. The performance of the alternative models is period-dependent, but generally we observe that: (1) where a profile is available, the square-root-of-impedance method outperforms VS30 (average S-wave velocity to 30 m depth), and (2) where a profile is unavailable, the topographic-slope method outperforms surficial geology. The fundamental site frequency is a valuable site response explanatory variable, though less valuable than VS30. However, given the expense and difficulty of obtaining reliable estimates of VS30 and the relative ease with which the fundamental site frequency can be computed, the fundamental site frequency may prove to be a valuable site response explanatory variable for many applications. ?? 2011 ASCE.

  9. Transient regime in second harmonic generation

    NASA Astrophysics Data System (ADS)

    Szeftel, Jacob; Sandeau, Laure; Sandeau, Nicolas; Delezoide, Camille; Khater, Antoine

    2013-09-01

    The time growth of the electromagnetic field at the fundamental and double frequencies is studied from the very onset of the second harmonic generation (SHG) process for a set of dipoles lacking a symmetry centre and exhibiting a nonresonant coupling with a classical electromagnetic field. This approach consists first of solving the Schrödinger equation by applying a generalised Rabi rotation to the Hamiltonian describing the light-dipole interaction. This rotation has been devised for the resulting Hamiltonian to show up time-independent for both components of the electromagnetic field at the fundamental frequency and the second harmonic one. Then an energy conservation argument, derived from the Poynting theorem, is introduced to work out an additional relationship between the electromagnetic field and its associated electric polarisation. Finally this analysis yields the full time behaviour of all physical quantities of interest. The calculated results reproduce accurately both the observed spatial oscillations of the SHG intensity (Maker's fringes) and its power law dependence on the intensity of the incoming light at the fundamental frequency.

  10. Testing a model of intonation in a tone language.

    PubMed

    Lindau, M

    1986-09-01

    Schematic fundamental frequency curves of simple statements and questions are generated for Hausa, a two-tone language of Nigeria, using a modified version of an intonational model developed by Gårding and Bruce [Nordic Prosody II, edited by T. Fretheim (Tapir, Trondheim, 1981), pp. 33-39]. In this model, rules for intonation and tones are separated. Intonation is represented as sloping grids of (near) parallel lines, inside which tones are placed. The tones are associated with turning points of the fundamental frequency contour. Local rules may also modify the exact placement of a tone within the grid. The continuous fundamental frequency contour is modeled by concatenating the tonal points using polynomial equations. Thus the final pitch contour is modeled as an interaction between global and local factors. The slope of the intonational grid lines depends at least on sentence type (statement or question), sentence length, and tone pattern. The model is tested by reference to data from nine speakers of Kano Hausa.

  11. Vibration characteristics of a deployable controllable-geometry truss boom

    NASA Technical Reports Server (NTRS)

    Dorsey, J. T.

    1983-01-01

    An analytical study was made to evaluate changes in the fundamental frequency of a two dimensional cantilevered truss boom at various stages of deployment. The truss could be axially deployed or retracted and undergo a variety of controlled geometry changes by shortening or lengthening the telescoping diagonal members in each bay. Both untapered and tapered versions of the truss boom were modeled and analyzed by using the finite element method. Large reductions in fundamental frequency occurred for both the untapered and tapered trusses when they were uniformly retracted or maneuvered laterally from their fully deployed position. These frequency reductions can be minimized, however, if truss geometries are selected which maintain cantilever root stiffness during truss maneuvers.

  12. A frequency doubled pressure-tunable oscillator-amplifier dye laser system

    NASA Technical Reports Server (NTRS)

    Moriarty, A.; Heaps, W.; Davis, D. D.

    1976-01-01

    A tunable high-repetition-rate oscillator-amplifier dye-laser system is reported. The dye laser described was longitudinally pumped with the second harmonic of a Nd-YAG laser operating at 10 Hz. Using three Faraday-Perot etalons and pressure tuning, a maximum fundamental output power of the order of 6 MW with a corresponding spectral width of less than 0.003 nm at 564 nm was obtained. The fundamental at 564 nm was frequency doubled to give a maximum power level of 0.6 MW of second-harmonic output power with a spectral width less than 0.0015 nm at 282 nm. Frequency stability could be maintained to within approximately 15% of the line-width.

  13. Evaluation of local site effect from microtremor measurements in Babol City, Iran

    NASA Astrophysics Data System (ADS)

    Rezaei, Sadegh; Choobbasti, Asskar Janalizadeh

    2018-03-01

    Every year, numerous casualties and a large deal of financial losses are incurred due to earthquake events. The losses incurred by an earthquake vary depending on local site effect. Therefore, in order to conquer drastic effects of an earthquake, one should evaluate urban districts in terms of the local site effect. One of the methods for evaluating the local site effect is microtremor measurement and analysis. Aiming at evaluation of local site effect across the city of Babol, the study area was gridded and microtremor measurements were performed with an appropriate distribution. The acquired data was analyzed through the horizontal-to-vertical noise ratio (HVNR) method, and fundamental frequency and associated amplitude of the H/V peak were obtained. The results indicate that fundamental frequency of the study area is generally lower than 1.25 Hz, which is acceptably in agreement with the findings of previous studies. Also, in order to constrain and validate the seismostratigraphic model obtained with this method, the results were compared with geotechnical, geological, and seismic data. Comparing the results of different methods, it was observed that the presented geophysical method can successfully determine the values of fundamental frequency across the study area as well as local site effect. Using the data obtained from the analysis of microtremor, a microzonation map of fundamental frequency across the city of Babol was prepared. This map has numerous applications in designing high-rise building and urban development plans.

  14. Fundamental frequency, phonation maximum time and vocal complaints in morbidly obese women

    PubMed Central

    de SOUZA, Lourdes Bernadete Rocha; PEREIRA, Rayane Medeiros; dos SANTOS, Marquiony Marques; GODOY, Cynthia Meida de Almeida

    2014-01-01

    Background Obese people have abnormal deposition of fat in the vocal tract that can interfere with the acoustic voice. Aim To relate the fundamental frequency, the maximum phonation time and voice complaints from a group of morbidly obese women. Methods Observational, cross-sectional and descriptive study that included 44 morbidly obese women, mean age of 42.45 (±10.31) years old, observational group and 30 women without obesity, control group, with 33.79 (±4.51)years old. The voice recording was done in a quiet environment, on a laptop using the program ANAGRAF acoustic analysis of speech sounds. To extract the values ​​of fundamental frequency the subjects were asked to produce vowel [a] at usual intensity for a period in average of three seconds. After the voice recording, participants were prompted to produce sustained vowel [ a] , [ i] and [ u] at usual intensity and height, using a stopwatch to measure the time that each participant could hold each vowel. Results The majority, 31(70.5%), had vocal complaints, with a higher percentage for complaints of vocal fatigue 20(64.51%) and voice failures 19(61.29%) followed by dryness of the throat in 15 (48.38%) and effort to speak 13(41.93%). There was no statistically significant difference regarding the mean fundamental frequency of the voice in both groups, but there was significance between the two groups regarding maximum phonation. Conclusion Increased adipose tissue in the vocal tract interfered in the vocal parameters. PMID:24676298

  15. Gender differences in children's voice use in a day care environment.

    PubMed

    Nygren, Mariana; Tyboni, Mikaela; Lindström, Fredric; McAllister, Anita; van Doorn, Jan

    2012-11-01

    The prevalence of dysphonia is higher in boys than in girls before puberty. This could be because of the differences in boys' and girls' voice use. Previous research on gender differences in prepubescent children's voice parameters has been contradictory. Most studies have focused on examining fundamental frequency. The purpose of this study was to investigate voice use in boys and girls in a day care environment based on the voice parameters fundamental frequency (Hz), vocal intensity (dB SPL), and phonation time (%) and to ascertain whether there were any significant gender differences. Prospective comparative design. The study was conducted in a day care environment where 30 children (17 boys and 13 girls aged 4-5 years) participated. The participants' voices were measured continuously for 4 hours with a voice accumulator that registered fundamental frequency, vocal intensity level, phonation time, and background noise. Mean (standard deviation) fundamental frequency was 310 (22) and 321 (16) Hz, vocal intensity was 93 (4) and 91 (3) dB SPL, and phonation time was 7.7 (2.0)% and 7.6 (2.5)% for boys and girls, respectively. No differences between genders were statistically significant. The finding of no statistically significant gender differences for measurements of voice parameters in a group of children aged 4-5 years in a day care environment is an important finding that contributes to increased knowledge about young boys' and girls' voice use. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  16. Pre-patterned ZnO nanoribbons on soft substrates for stretchable energy harvesting applications

    NASA Astrophysics Data System (ADS)

    Ma, Teng; Wang, Yong; Tang, Rui; Yu, Hongyu; Jiang, Hanqing

    2013-05-01

    Three pre-patterned ZnO nanoribbons in different configurations were studied in this paper, including (a) straight ZnO nanoribbons uniformly bonded on soft substrates that form sinusoidal buckles, (b) straight ZnO nanoribbons selectively bonded on soft substrates that form pop-up buckles, and (c) serpentine ZnO nanoribbons bonded on soft substrates via anchors. The nonlinear dynamics and random analysis were conducted to obtain the fundamental frequencies and to evaluate their performance in energy harvesting applications. We found that pop-up buckles and overhanging serpentine structures are suitable for audio frequency energy harvesting applications. Remarkably, almost unchanged fundamental natural frequency upon strain is achieved by properly patterning ZnO nanoribbons, which initiates a new and exciting direction of stretchable energy harvesting using nano-scale materials in audio frequency range.

  17. High-efficiency frequency doubling of continuous-wave laser light.

    PubMed

    Ast, Stefan; Nia, Ramon Moghadas; Schönbeck, Axel; Lastzka, Nico; Steinlechner, Jessica; Eberle, Tobias; Mehmet, Moritz; Steinlechner, Sebastian; Schnabel, Roman

    2011-09-01

    We report on the observation of high-efficiency frequency doubling of 1550 nm continuous-wave laser light in a nonlinear cavity containing a periodically poled potassium titanyl phosphate crystal (PPKTP). The fundamental field had a power of 1.10 W and was converted into 1.05 W at 775 nm, yielding a total external conversion efficiency of 95±1%. The latter value is based on the measured depletion of the fundamental field being consistent with the absolute values derived from numerical simulations. According to our model, the conversion efficiency achieved was limited by the nonperfect mode matching into the nonlinear cavity and by the nonperfect impedance matching for the maximum input power available. Our result shows that cavity-assisted frequency conversion based on PPKTP is well suited for low-decoherence frequency conversion of quantum states of light.

  18. Dependence of sound characteristics on the bowing position in a violin

    NASA Astrophysics Data System (ADS)

    Roh, YuJi; Kim, Young H.

    2014-12-01

    A quantitative analysis of violin sounds produced for different bowing positions over the full length of a violin string has been carried out. An automated bowing machine was employed in order to keep the bowing parameters constant. A 3-dimensional profile of the frequency spectrum was introduced in order to characterize the violin's sound. We found that the fundamental frequency did not change for different bowing positions, whereas the frequencies of the higher harmonics were different. Bowing the string at 30 mm from the bridge produced musical sounds. The middle of the string was confirmed to be a dead zone, as reported in previous works. In addition, the quarter position was also found to be a dead zone. Bowing the string 90 mm from the bridge dominantly produces a fundamental frequency of 864 Hz and its harmonics.

  19. A new approach to harmonic elimination based on a real-time comparison method

    NASA Astrophysics Data System (ADS)

    Gourisetti, Sri Nikhil Gupta

    Undesired harmonics are responsible for noise in a transmission channel, power loss in power electronics and in motor control. Selective Harmonic Elimination (SHE) is a well-known method used to eliminate or suppress the unwanted harmonics between the fundamental and the carrier frequency harmonic/component. But SHE bears the disadvantage of its incapability to use in real-time applications. A novel reference-carrier comparative method has been developed which can be used to generate an SPWM signal to apply in real-time systems. A modified carrier signal is designed and tested for different carrier frequencies based on the generated SPWM FFT. The carrier signal may change for different fundamental to carrier ratio that leads to solving the equations each time. An analysis to find all possible solutions for a particular carrier frequency and fundamental amplitude is performed and found. This proves that there is no one global maxima instead several local maximas exists for a particular condition set that makes this method less sensitive. Additionally, an attempt to find a universal solution that is valid for any carrier signal with predefined fundamental amplitude is performed. A uniform distribution Monte-Carlo sensitivity analysis is performed to measure the window i.e., best and worst possible solutions. The simulations are performed using MATLAB and are justified with experimental results.

  20. High order harmonics anomaly of jet screech

    NASA Astrophysics Data System (ADS)

    Chen, Zhe; Wu, Jiu Hui; Ren, A.-Dan; Chen, Xin

    2018-05-01

    Imperfectly expanded supersonic jets under strong screech could generate both fundamental screech tones and multiple tones at the harmonics of the fundamental frequency. The paper compares the fundamental frequency of jets from both AR = 3 (Aspect Ratio) and AR = 4 rectangular nozzles, and conducts analysis of harmonics on Sound Pressure Level (SPL) spectrums of jet noise. The research suggests that the fundamental frequency of the first two- or three-order harmonics increases when the Nozzle Pressure Ratio (NPR) decreases, whereas the highest order harmonic decreases when the NPR decreases. Besides, the paper also observes the differences between the highest order harmonics and other harmonics that have never been reported before. Further analysis on flow field schlieren of AR = 3 nozzle indicates that the highest order harmonic is the outcome of interaction between second shock-cell and nonlinear instable wave. The revolution of these high order harmonics can provide guidance for the prevention of small-scale structure fatigue damage. Moreover, the distribution test of the noises is also carried out to verify the high order harmonics anomaly, and indicate that the jet noise spreads mainly towards downstream while screech towards upstream. In addition, the broadband shock-associated noise spreads vertical to the jet flow and exhibits the feature of directivity.

  1. Impact of the phase-mismatch in the SHG crystal and consequential self-action of the fundamental wave by cascaded second-order effects on the THG efficiency of a Q-switched 1342 nm Nd:YVO₄ laser.

    PubMed

    Koch, Peter; Bartschke, Juergen; L'huillier, Johannes A

    2015-05-18

    We report on the influence of self-focusing and self-defocusing in the phase-mismatched frequency doubling crystal on the third harmonic generation (THG) efficiency in a two crystal frequency tripling scheme. By detuning the temperature of the doubling crystal, the impact of a phase-mismatch in second harmonic generation (SHG) on the subsequent sum frequency mixing process was investigated. It was found that adjusting the temperature not only affected the power ratio of the second harmonic to the fundamental but also the beam diameter of the fundamental beam in the THG crystal, which was caused by self-focusing and self-defocusing of the fundamental beam, respectively. This self-action was induced by a cascaded χ(2) : χ(2) process in the phase-mismatched SHG crystal. Self-defocusing was observable for positive detuning and self-focusing for negative detuning of the phase-matching temperature. Hence, the THG efficiency was not symmetric with respect to the point of optimum phase-matching. Optimum THG was obtained for positive detuning and the resulting self-defocusing in combination with the focusing lens in front of the THG stage was also beneficial for the beam quality of the third harmonic.

  2. All-optical and broadband microwave fundamental/sub-harmonic I/Q down-converters.

    PubMed

    Gao, Yongsheng; Wen, Aijun; Jiang, Wei; Fan, Yangyu; He, You

    2018-03-19

    Microwave I/Q down-converters are frequently used in image-reject super heterodyne receivers, zero intermediate frequency (zero-IF) receivers, and phase/frequency discriminators. However, due to the electronic bottleneck, conventional microwave I/Q mixers face a serious bandwidth limitation, I/Q imbalance, and even-order distortion. In this paper, photonic microwave fundamental and sub-harmonic I/Q down-converters are presented using a polarization division multiplexing dual-parallel Mach-Zehnder modulator (PDM-DPMZM). Thanks to all-optical manipulation, the proposed system features an ultra-wide operating band (7-40 GHz in the fundamental I/Q down-converter, and 10-40 GHz in the sub-harmonic I/Q down-converter) and an excellent I/Q balance (maximum 0.7 dB power imbalance and 1 degree phase imbalance). The conversion gain, noise figure (NF), even-order distortion, and spurious free dynamic range (SFDR) are also improved by LO power optimization and balanced detection. Using the proposed system, a high image rejection ratio is demonstrated for a super heterodyne receiver, and good EVMs over a wide RF power range is demonstrated for a zero-IF receiver. The proposed broadband photonic microwave fundamental and sub-harmonic I/Q down-converters may find potential applications in multi-band satellite, ultra-wideband radar and frequency-agile electronic warfare systems.

  3. 225-255-GHz InP DHBT Frequency Tripler MMIC Using Complementary Split-Ring Resonator

    NASA Astrophysics Data System (ADS)

    Li, Xiao; Zhang, Yong; Li, Oupeng; Sun, Yan; Lu, Haiyan; Cheng, Wei; Xu, Ruimin

    2017-02-01

    In this paper, a novel design of frequency tripler monolithic microwave integrated circuit (MMIC) using complementary split-ring resonator (CSRR) is proposed based on 0.5-μm InP DHBT process. The CSRR-loaded microstrip structure is integrated in the tripler as a part of impedance matching network to suppress the fundamental harmonic, and another frequency tripler based on conventional band-pass filter is presented for comparison. The frequency tripler based on CSRR-loaded microstrip generates an output power between -8 and -4 dBm from 228 to 255 GHz when the input power is 6 dBm. The suppression of fundamental harmonic is better than 20 dBc at 77-82 GHz input frequency within only 0.15 × 0.15 mm2 chip area of the CSRR structure on the ground layer. Compared with the frequency tripler based on band-pass filter, the tripler using CSRR-loaded microstrip obtains a similar suppression level of unwanted harmonics and higher conversion gain within a much smaller chip area. To our best knowledge, it is the first time that CSRR is used for harmonic suppression of frequency multiplier at such high frequency band.

  4. Some new results on the frequency characteristics on quartz crystals irradiated by ionizing and particle radiations

    NASA Technical Reports Server (NTRS)

    Bahadur, H.; Parshad, R.

    1981-01-01

    The frequency behavior of AT-cut quartz crystals irradiated by X -, gamma rays and fast neutrons. Initial instability in frequency for gamma and neutron irradiated crystals was found. All the different radiations first give a negative frequency shift at lower doses which are followed by positive frequency shift for increased doses. Results are explained in terms of the fundamental crystal structure. Applications of the frequency results for radiation hardening are proposed.

  5. How-to-Do-It: Hands-on Activity for Mitosis, Meiosis and the Fundamentals of Heredity.

    ERIC Educational Resources Information Center

    Taylor, Mark F.

    1988-01-01

    Described is an exercise which uses inexpensive and easy-to-make materials to demonstrate the basic fundamentals of heredity. Discusses two approaches using a hypothetical insert to demonstrate inheritance, mitosis, meiosis, and genotypic and phenotypic frequencies. (CW)

  6. A New Type of Atom Interferometry for Testing Fundamental Physics

    NASA Astrophysics Data System (ADS)

    Lorek, Dennis; Lämmerzahl, Claus; Wicht, Andreas

    We present a new type of atom interferometer (AI) that provides a tool for ultra-high precision tests of fundamental physics. As an example we present how an AI based on highly charged hydrogen-like atoms is affected by gravitational waves (GW). A qualitative description of the quantum interferometric measurement principle is given, the modifications in the atomic Hamiltonian caused by the GW are presented, and the size of the resulting frequency shifts in hydrogen-like atoms is estimated. For a GW amplitude of h = 10-23 the frequency shift is of the order of 110μHz for an AI based on a 91-fold charged uranium ion. A frequency difference of this size can be resolved by current AIs in 1s.

  7. Frequency-doubled vertical-external-cavity surface-emitting laser

    DOEpatents

    Raymond, Thomas D.; Alford, William J.; Crawford, Mary H.; Allerman, Andrew A.

    2002-01-01

    A frequency-doubled semiconductor vertical-external-cavity surface-emitting laser (VECSEL) is disclosed for generating light at a wavelength in the range of 300-550 nanometers. The VECSEL includes a semiconductor multi-quantum-well active region that is electrically or optically pumped to generate lasing at a fundamental wavelength in the range of 600-1100 nanometers. An intracavity nonlinear frequency-doubling crystal then converts the fundamental lasing into a second-harmonic output beam. With optical pumping with 330 milliWatts from a semiconductor diode pump laser, about 5 milliWatts or more of blue light can be generated at 490 nm. The device has applications for high-density optical data storage and retrieval, laser printing, optical image projection, chemical-sensing, materials processing and optical metrology.

  8. Applications of computer algebra to distributed parameter systems

    NASA Technical Reports Server (NTRS)

    Storch, Joel A.

    1993-01-01

    In the analysis of vibrations of continuous elastic systems, one often encounters complicated transcendental equations with roots directly related to the system's natural frequencies. Typically, these equations contain system parameters whose values must be specified before a numerical solution can be obtained. The present paper presents a method whereby the fundamental frequency can be obtained in analytical form to any desired degree of accuracy. The method is based upon truncation of rapidly converging series involving inverse powers of the system natural frequencies. A straightforward method to developing these series and summing them in closed form is presented. It is demonstrated how Computer Algebra can be exploited to perform the intricate analytical procedures which otherwise would render the technique difficult to apply in practice. We illustrate the method by developing two analytical approximations to the fundamental frequency of a vibrating cantilever carrying a rigid tip body. The results are compared to the numerical solution of the exact (transcendental) frequency equation over a range of system parameters.

  9. Estimation of Frequency Noise in Semiconductor Lasers Due to Mechanical Thermal Noise

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Camp, Jordan

    2012-01-01

    We evaluate mechanical thermal noise in semiconductor lasers, applying a methodology developed for fixed-spacer cavities for laser frequency stabilization. Our simple model determines an underlying fundamental limit for the frequency noise of free-running semiconductor laser, and provides a framework: where the noise may be potentially reduced with improved design.

  10. Effect of ultrasonic cavitation on measurement of sound pressure using hydrophone

    NASA Astrophysics Data System (ADS)

    Thanh Nguyen, Tam; Asakura, Yoshiyuki; Okada, Nagaya; Koda, Shinobu; Yasuda, Keiji

    2017-07-01

    Effect of ultrasonic cavitation on sound pressure at the fundamental, second harmonic, and first ultraharmonic frequencies was investigated from low to high ultrasonic intensities. The driving frequencies were 22, 304, and 488 kHz. Sound pressure was measured using a needle-type hydrophone and ultrasonic cavitation was estimated from the broadband integrated pressure (BIP). With increasing square root of electric power applied to a transducer, the sound pressure at the fundamental frequency linearly increased initially, dropped at approximately the electric power of cavitation inception, and afterward increased again. The sound pressure at the second harmonic frequency was detected just below the electric power of cavitation inception. The first ultraharmonic component appeared at around the electric power of cavitation inception at 304 and 488 kHz. However, at 22 kHz, the first ultraharmonic component appeared at a higher electric power than that of cavitation inception.

  11. Investigations of HID Lamp Electrodes under HF Operation

    NASA Astrophysics Data System (ADS)

    Reinelt, Jens; Langenscheidt, Oliver; Westermeier, Michael; Mentel, Juergen; Awakowicz, Peter

    2007-10-01

    Low pressure lamps are operated many years at high frequencies to improve the efficiency of these lamps and drivers. For high pressure discharge lamps this operation mode has not been installed yet. Generally it can be assumed that there are changes in the electrode physics which may lead to an undesired lamp behavior if HID lamps are operated at a high frequency. To gain insights into these fundamental changes the so called Bochum Model Lamp is used. It is an easy system which allows a fundamental research on HID electrode behavior and the near electrode region without the occurrence of acoustic resonances. For the investigation phase resolved photography, pyrometry and spectrometry is used. The presented results describe changes in the electrode temperature and changes in the kind of arc attachment on the electrodes (diffuse and spot mode) depending on frequency. Also measurements of the Electrode-Sheath-Voltage (ESV), depending on frequency, are presented.

  12. The ACES mission: scientific objectives and present status

    NASA Astrophysics Data System (ADS)

    Cacciapuoti, L.; Dimarcq, N.; Salomon, C.

    2017-11-01

    "Atomic Clock Ensemble in Space" (ACES) is a mission in fundamental physics that will operate a new generation of atomic clocks in the microgravity environment of the International Space Station (ISS). The ACES clock signal will combine the medium term frequency stability of a space hydrogen maser (SHM) and the long term stability and accuracy of a frequency standard based on cold cesium atoms (PHARAO). Fractional frequency stability and accuracy of few parts in 1016 will be achieved. The on-board time base distributed on Earth via a microwave link (MWL) will be used to test fundamental laws of physics (Einstein's theories of Special and General Relativity, Standard Model Extension, string theories…) and to develop applications in time and frequency metrology, universal time scales, global positioning and navigation, geodesy and gravimetry. After a general overview on the mission concept and its scientific objectives, the present status of ACES instruments and sub-systems will be discussed.

  13. Modeling hemoglobin at optical frequency using the unconditionally stable fundamental ADI-FDTD method.

    PubMed

    Heh, Ding Yu; Tan, Eng Leong

    2011-04-12

    This paper presents the modeling of hemoglobin at optical frequency (250 nm - 1000 nm) using the unconditionally stable fundamental alternating-direction-implicit finite-difference time-domain (FADI-FDTD) method. An accurate model based on complex conjugate pole-residue pairs is proposed to model the complex permittivity of hemoglobin at optical frequency. Two hemoglobin concentrations at 15 g/dL and 33 g/dL are considered. The model is then incorporated into the FADI-FDTD method for solving electromagnetic problems involving interaction of light with hemoglobin. The computation of transmission and reflection coefficients of a half space hemoglobin medium using the FADI-FDTD validates the accuracy of our model and method. The specific absorption rate (SAR) distribution of human capillary at optical frequency is also shown. While maintaining accuracy, the unconditionally stable FADI-FDTD method exhibits high efficiency in modeling hemoglobin.

  14. Modeling hemoglobin at optical frequency using the unconditionally stable fundamental ADI-FDTD method

    PubMed Central

    Heh, Ding Yu; Tan, Eng Leong

    2011-01-01

    This paper presents the modeling of hemoglobin at optical frequency (250 nm – 1000 nm) using the unconditionally stable fundamental alternating-direction-implicit finite-difference time-domain (FADI-FDTD) method. An accurate model based on complex conjugate pole-residue pairs is proposed to model the complex permittivity of hemoglobin at optical frequency. Two hemoglobin concentrations at 15 g/dL and 33 g/dL are considered. The model is then incorporated into the FADI-FDTD method for solving electromagnetic problems involving interaction of light with hemoglobin. The computation of transmission and reflection coefficients of a half space hemoglobin medium using the FADI-FDTD validates the accuracy of our model and method. The specific absorption rate (SAR) distribution of human capillary at optical frequency is also shown. While maintaining accuracy, the unconditionally stable FADI-FDTD method exhibits high efficiency in modeling hemoglobin. PMID:21559129

  15. Apparatus and method for qualitative and quantitative measurements of optical properties of turbid media using frequency-domain photon migration

    DOEpatents

    Tromberg, B.J.; Tsay, T.T.; Berns, M.W.; Svaasand, L.O.; Haskell, R.C.

    1995-06-13

    Optical measurements of turbid media, that is media characterized by multiple light scattering, is provided through an apparatus and method for exposing a sample to a modulated laser beam. The light beam is modulated at a fundamental frequency and at a plurality of integer harmonics thereof. Modulated light is returned from the sample and preferentially detected at cross frequencies at frequencies slightly higher than the fundamental frequency and at integer harmonics of the same. The received radiance at the beat or cross frequencies is compared against a reference signal to provide a measure of the phase lag of the radiance and modulation ratio relative to a reference beam. The phase and modulation amplitude are then provided as a frequency spectrum by an array processor to which a computer applies a complete curve fit in the case of highly scattering samples or a linear curve fit below a predetermined frequency in the case of highly absorptive samples. The curve fit in any case is determined by the absorption and scattering coefficients together with a concentration of the active substance in the sample. Therefore, the curve fitting to the frequency spectrum can be used both for qualitative and quantitative analysis of substances in the sample even though the sample is highly turbid. 14 figs.

  16. Apparatus and method for qualitative and quantitative measurements of optical properties of turbid media using frequency-domain photon migration

    DOEpatents

    Tromberg, Bruce J.; Tsay, Tsong T.; Berns, Michael W.; Svaasand, Lara O.; Haskell, Richard C.

    1995-01-01

    Optical measurements of turbid media, that is media characterized by multiple light scattering, is provided through an apparatus and method for exposing a sample to a modulated laser beam. The light beam is modulated at a fundamental frequency and at a plurality of integer harmonics thereof. Modulated light is returned from the sample and preferentially detected at cross frequencies at frequencies slightly higher than the fundamental frequency and at integer harmonics of the same. The received radiance at the beat or cross frequencies is compared against a reference signal to provide a measure of the phase lag of the radiance and modulation ratio relative to a reference beam. The phase and modulation amplitude are then provided as a frequency spectrum by an array processor to which a computer applies a complete curve fit in the case of highly scattering samples or a linear curve fit below a predetermined frequency in the case of highly absorptive samples. The curve fit in any case is determined by the absorption and scattering coefficients together with a concentration of the active substance in the sample. Therefore, the curve fitting to the frequency spectrum can be used both for qualitative and quantitative analysis of substances in the sample even though the sample is highly turbid.

  17. Neck Circumference and Vocal Parameters in Women Before and After Bariatric Surgery.

    PubMed

    de Souza, Lourdes Bernadete Rocha; Pernambuco, Leandro de Araújo; dos Santos, Marquiony Marques; Pereira, Rayane Medeiros

    2016-03-01

    Morbidly obese patients may suffer from vocal disorders, as vocal production is directly related to the volume of the vocal tract, and the large-scale accumulation of fat in this region may interfere with voice production. The aim of this study was to analyze the neck circumference, fundamental frequency, and maximum phonation time of a group of morbidly obese women before and after bariatric surgery. An observational, longitudinal, and descriptive study was performed with patients of the Obesity and Related Diseases Surgery Unit of a university hospital. A total of 21 morbidly obese women aged 28-68 years, with a mean age of 41.33 years, participated in the study. Neck circumference was measured using a tape measure. To obtain fundamental frequency values, the patient was asked to produce the vowel [a] at normal intensity and pitch for an average period of 3 s. After recording, the participants were asked to produce the sustained vowels [a], [i], and [u] at normal intensity and pitch, with a stopwatch used to measure maximum phonation time. Eight months after surgery, patients were reassessed using the same data collecting procedures as were carried out prior to surgery. After surgery, there was an increase in the average value of fundamental frequency and maximum phonation time for all the vowels and a reduction in neck circumference. The differences were statistically significant. Weight reduction and a consequent decrease in neck circumference affected the changes in maximum phonation time and fundamental frequency values in the voices of these patients, after weight loss.

  18. Multiscale energy reallocation during low-frequency steady-state brain response.

    PubMed

    Wang, Yifeng; Chen, Wang; Ye, Liangkai; Biswal, Bharat B; Yang, Xuezhi; Zou, Qijun; Yang, Pu; Yang, Qi; Wang, Xinqi; Cui, Qian; Duan, Xujun; Liao, Wei; Chen, Huafu

    2018-05-01

    Traditional task-evoked brain activations are based on detection and estimation of signal change from the mean signal. By contrast, the low-frequency steady-state brain response (lfSSBR) reflects frequency-tagging activity at the fundamental frequency of the task presentation and its harmonics. Compared to the activity at these resonant frequencies, brain responses at nonresonant frequencies are largely unknown. Additionally, because the lfSSBR is defined by power change, we hypothesize using Parseval's theorem that the power change reflects brain signal variability rather than the change of mean signal. Using a face recognition task, we observed power increase at the fundamental frequency (0.05 Hz) and two harmonics (0.1 and 0.15 Hz) and power decrease within the infra-slow frequency band (<0.1 Hz), suggesting a multifrequency energy reallocation. The consistency of power and variability was demonstrated by the high correlation (r > .955) of their spatial distribution and brain-behavior relationship at all frequency bands. Additionally, the reallocation of finite energy was observed across various brain regions and frequency bands, forming a particular spatiotemporal pattern. Overall, results from this study strongly suggest that frequency-specific power and variability may measure the same underlying brain activity and that these results may shed light on different mechanisms between lfSSBR and brain activation, and spatiotemporal characteristics of energy reallocation induced by cognitive tasks. © 2018 Wiley Periodicals, Inc.

  19. Pneumatic oscillator circuits for timing and control of integrated microfluidics.

    PubMed

    Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

    2013-11-05

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.

  20. Stimulus presentation order and the perception of lexical tones in Cantonese

    NASA Astrophysics Data System (ADS)

    Francis, Alexander L.; Ciocca, Valter

    2003-09-01

    Listeners' auditory discrimination of vowel sounds depends in part on the order in which stimuli are presented. Such presentation order effects have been argued to be language independent, and to result from psychophysical (not speech- or language-specific) factors such as the decay of memory traces over time or increased weighting of later-occurring stimuli. In the present study, native Cantonese speakers' discrimination of a linguistic tone continuum is shown to exhibit order of presentation effects similar to those shown for vowels in previous studies. When presented with two successive syllables differing in fundamental frequency by approximately 4 Hz, listeners were significantly more sensitive to this difference when the first syllable was higher in frequency than the second. However, American English-speaking listeners with no experience listening to Cantonese showed no such contrast effect when tested in the same manner using the same stimuli. Neither English nor Cantonese listeners showed any order of presentation effects in the discrimination of a nonspeech continuum in which tokens had the same fundamental frequencies as the Cantonese speech tokens but had a qualitatively non-speech-like timbre. These results suggest that tone presentation order effects, unlike vowel effects, may be language specific, possibly resulting from the need to compensate for utterance-related pitch declination when evaluating fundamental frequency for tone identification.

  1. Improvement of Microtremor Data Filtering and Processing Methods Used in Determining the Fundamental Frequency of Urban Areas

    NASA Astrophysics Data System (ADS)

    Mousavi Anzehaee, Mohammad; Adib, Ahmad; Heydarzadeh, Kobra

    2015-10-01

    The manner of microtremor data collection and filtering operation and also the method used for processing have a considerable effect on the accuracy of estimation of dynamic soil parameters. In this paper, running variance method was used to improve the automatic detection of data sections infected by local perturbations. In this method, the microtremor data running variance is computed using a sliding window. Then the obtained signal is used to remove the ranges of data affected by perturbations from the original data. Additionally, to determinate the fundamental frequency of a site, this study has proposed a statistical characteristics-based method. Actually, statistical characteristics, such as the probability density graph and the average and the standard deviation of all the frequencies corresponding to the maximum peaks in the H/ V spectra of all data windows, are used to differentiate the real peaks from the false peaks resulting from perturbations. The methods have been applied to the data recorded for the City of Meybod in central Iran. Experimental results show that the applied methods are able to successfully reduce the effects of extensive local perturbations on microtremor data and eventually to estimate the fundamental frequency more accurately compared to other common methods.

  2. The acoustic structure of male giant panda bleats varies according to intersexual context.

    PubMed

    Charlton, Benjamin D; Keating, Jennifer L; Rengui, Li; Huang, Yan; Swaisgood, Ronald R

    2015-09-01

    Although the acoustic structure of mammal vocal signals often varies according to the social context of emission, relatively few mammal studies have examined acoustic variation during intersexual advertisement. In the current study male giant panda bleats were recorded during the breeding season in three behavioural contexts: vocalising alone, during vocal interactions with females outside of peak oestrus, and during vocal interactions with peak-oestrous females. Male bleats produced during vocal interactions with peak-oestrous females were longer in duration and had higher mean fundamental frequency than those produced when males were either involved in a vocal interaction with a female outside of peak oestrus or vocalising alone. In addition, males produced bleats with higher rates of fundamental frequency modulation when they were vocalising alone than when they were interacting with females. These results show that acoustic features of male giant panda bleats have the potential to signal the caller's motivational state, and suggest that males increase the rate of fundamental frequency modulation in bleats when they are alone to maximally broadcast their quality and promote close-range contact with receptive females during the breeding season.

  3. An injection-locked OEO based frequency doubler independent of electrical doubler phase noise deteriorating rule

    NASA Astrophysics Data System (ADS)

    Xie, Zhengyang; Zheng, Xiaoping; Li, Shangyuan; Yan, Haozhe; Xiao, Xuedi; Xue, Xiaoxiao

    2018-06-01

    We propose an injection-locked optoelectronic oscillator (OEO) based wide-band frequency doubler, which is free from phase noise deterioration in electrical doubler, by using a dual-parallel Mach-Zehnder modulator (DPMZM). Through adjusting the optical phase shifts in different arms of the DPMZM, the doubling signal oscillates in the OEO loop while the fundamental signal takes on phase modulation over the light and vanishes at photo-detector (PD) output. By controlling power of fundamental signal the restriction of phase-noise deterioration rule in electrical doubler is totally canceled. Experimental results show that the doubler output has a better phase noise value of, for example, -117 dBc/Hz @ 10 kHz at 6 GHz with an improvement more than 17 dB and 23 dB compared with that of fundamental input and electrical doubler, respectively. Besides, the stability of this doubler output can reach to 1 . 5 × 10-14 at 1000 s averaging time. The frequency range of doubling signal is limited by the bandwidth of electrical amplifier in OEO loop.

  4. Suspension-thermal noise in spring–antispring systems for future gravitational-wave detectors

    NASA Astrophysics Data System (ADS)

    Harms, Jan; Mow-Lowry, Conor M.

    2018-01-01

    Spring–antispring systems have been investigated in the context of low-frequency seismic isolation in high-precision optical experiments. These systems provide the possibility to tune the fundamental resonance frequency to, in principle, arbitrarily low values, and at the same time maintain a compact design. It was argued though that thermal noise in spring–antispring systems would not be as small as one may naively expect from lowering the fundamental resonance frequency. In this paper, we present calculations of suspension-thermal noise for spring–antispring systems potentially relevant in future gravitational-wave detectors, i.e. the beam-balance tiltmeter, and the Roberts linkage. We find a concise expression of the suspension-thermal noise spectrum, which assumes a form very similar to the well-known expression for a simple pendulum. For systems such as the Roberts linkage foreseen as passive seismic isolation, we find that while they can provide strong seismic isolation due to a very low fundamental resonance frequency, their thermal noise is determined by the dimension of the system and is insensitive to fine-tunings of the geometry that can strongly influence the resonance frequency. By analogy, i.e. formal similarity of the equations of motion, this is true for all horizontal mechanical isolation systems with spring–antispring dynamics. This imposes strict requirements on mechanical spring–antispring systems for seismic isolation in potential future low-frequency gravitational-wave detectors as we discuss for the four main concepts, atom-interferometric, superconducting, torsion-bars, and conventional laser interferometer, and generally suggests that thermal noise needs to be evaluated carefully for high-precision experiments implementing spring–antispring dynamics.

  5. Base units of the SI, fundamental constants and modern quantum physics.

    PubMed

    Bordé, Christian J

    2005-09-15

    Over the past 40 years, a number of discoveries in quantum physics have completely transformed our vision of fundamental metrology. This revolution starts with the frequency stabilization of lasers using saturation spectroscopy and the redefinition of the metre by fixing the velocity of light c. Today, the trend is to redefine all SI base units from fundamental constants and we discuss strategies to achieve this goal. We first consider a kinematical frame, in which fundamental constants with a dimension, such as the speed of light c, the Planck constant h, the Boltzmann constant k(B) or the electron mass m(e) can be used to connect and redefine base units. The various interaction forces of nature are then introduced in a dynamical frame, where they are completely characterized by dimensionless coupling constants such as the fine structure constant alpha or its gravitational analogue alpha(G). This point is discussed by rewriting the Maxwell and Dirac equations with new force fields and these coupling constants. We describe and stress the importance of various quantum effects leading to the advent of this new quantum metrology. In the second part of the paper, we present the status of the seven base units and the prospects of their possible redefinitions from fundamental constants in an experimental perspective. The two parts can be read independently and they point to these same conclusions concerning the redefinitions of base units. The concept of rest mass is directly related to the Compton frequency of a body, which is precisely what is measured by the watt balance. The conversion factor between mass and frequency is the Planck constant, which could therefore be fixed in a realistic and consistent new definition of the kilogram based on its Compton frequency. We discuss also how the Boltzmann constant could be better determined and fixed to replace the present definition of the kelvin.

  6. The Josephson Effect and e/h

    ERIC Educational Resources Information Center

    Clarke, John

    1970-01-01

    Discusses the theory of the Josephson Effect, the derivation of the Josephson voltage-frequency relation, and methods of measuring the fundamental constatn ratio e/h. Various types of Josephson junctions are described. The impact of the measurement of e/h upin the fundamental constants and quantum electro-dynamics is briefly discussed.…

  7. Intrinsic fundamental frequency of vowels is moderated by regional dialect

    PubMed Central

    Jacewicz, Ewa; Fox, Robert Allen

    2015-01-01

    There has been a long-standing debate whether the intrinsic fundamental frequency (IF0) of vowels is an automatic consequence of articulation or whether it is independently controlled by speakers to perceptually enhance vowel contrasts along the height dimension. This paper provides evidence from regional variation in American English that IF0 difference between high and low vowels is, in part, controlled and varies across dialects. The sources of this F0 control are socio-cultural and cannot be attributed to differences in the vowel inventory size. The socially motivated enhancement was found only in prosodically prominent contexts. PMID:26520352

  8. A Preliminary Engineering Design of Intravascular Dual-Frequency Transducers for Contrast-Enhanced Acoustic Angiography and Molecular Imaging

    PubMed Central

    Ma, Jianguo; Martin, K. Heath; Dayton, Paul A.; Jiang, Xiaoning

    2014-01-01

    Current intravascular ultrasound (IVUS) probes are not optimized for contrast detection because of their design for high-frequency fundamental-mode imaging. However, data from transcutaneous contrast imaging suggests the possibility of utilizing contrast ultrasound for molecular imaging or vasa vasorum assessment to further elucidate atherosclerotic plaque deposition. This paper presents the design, fabrication, and characterization of a small-aperture (0.6 × 3 mm) IVUS probe optimized for high-frequency contrast imaging. The design utilizes a dual-frequency (6.5 MHz/30 MHz) transducer arrangement for exciting microbubbles at low frequencies (near their resonance) and detecting their broadband harmonics at high frequencies, minimizing detected tissue backscatter. The prototype probe is able to generate nonlinear microbubble response with more than 1.2 MPa of rarefractional pressure (mechanical index: 0.48) at 6.5 MHz, and is also able to detect microbubble response with a broadband receiving element (center frequency: 30 MHz, −6-dB fractional bandwidth: 58.6%). Nonlinear super-harmonics from microbubbles flowing through a 200-μm-diameter micro-tube were clearly detected with a signal-to-noise ratio higher than 12 dB. Preliminary phantom imaging at the fundamental frequency (30 MHz) and dual-frequency super-harmonic imaging results suggest the promise of small aperture, dual-frequency IVUS transducers for contrast-enhanced IVUS imaging. PMID:24801226

  9. Auditory perception bias in speech imitation

    PubMed Central

    Postma-Nilsenová, Marie; Postma, Eric

    2013-01-01

    In an experimental study, we explored the role of auditory perception bias in vocal pitch imitation. Psychoacoustic tasks involving a missing fundamental indicate that some listeners are attuned to the relationship between all the higher harmonics present in the signal, which supports their perception of the fundamental frequency (the primary acoustic correlate of pitch). Other listeners focus on the lowest harmonic constituents of the complex sound signal which may hamper the perception of the fundamental. These two listener types are referred to as fundamental and spectral listeners, respectively. We hypothesized that the individual differences in speakers' capacity to imitate F0 found in earlier studies, may at least partly be due to the capacity to extract information about F0 from the speech signal. Participants' auditory perception bias was determined with a standard missing fundamental perceptual test. Subsequently, speech data were collected in a shadowing task with two conditions, one with a full speech signal and one with high-pass filtered speech above 300 Hz. The results showed that perception bias toward fundamental frequency was related to the degree of F0 imitation. The effect was stronger in the condition with high-pass filtered speech. The experimental outcomes suggest advantages for fundamental listeners in communicative situations where F0 imitation is used as a behavioral cue. Future research needs to determine to what extent auditory perception bias may be related to other individual properties known to improve imitation, such as phonetic talent. PMID:24204361

  10. Voice stress analysis

    NASA Technical Reports Server (NTRS)

    Brenner, Malcolm; Shipp, Thomas

    1988-01-01

    In a study of the validity of eight candidate voice measures (fundamental frequency, amplitude, speech rate, frequency jitter, amplitude shimmer, Psychological Stress Evaluator scores, energy distribution, and the derived measure of the above measures) for determining psychological stress, 17 males age 21 to 35 were subjected to a tracking task on a microcomputer CRT while parameters of vocal production as well as heart rate were measured. Findings confirm those of earlier studies that increases in fundamental frequency, amplitude, and speech rate are found in speakers involved in extreme levels of stress. In addition, it was found that the same changes appear to occur in a regular fashion within a more subtle level of stress that may be characteristic, for example, of routine flying situations. None of the individual speech measures performed as robustly as did heart rate.

  11. Development of Multi-Degree-Of-Freedom Piezoelectric Energy Harvester Using Interdigital Shaped Cantilevers.

    PubMed

    Cho, Hyunok; Park, Jongcheol; Park, Jae Yeong

    2016-05-01

    A piezoelectric vibration energy harvester with interdigital shaped cantilever was developed by using silicon bulk micromachining technology. The proposed energy harvester was designed to obtain multi degree-of-freedom (m-DOF). Most of the piezoelectric vibration energy harvesters are comprised of mass-loaded cantilever beams having several resonant frequencies. The second resonant frequency of such a device has lower amplitude compared to its first resonant frequency (fundamental frequency). Therefore, the interdigital shaped cantilever has been proposed for multiple fundamental resonant frequencies. The fabricated piezoelectric vibration energy harvester is composed of main cantilever (MC), sub-main cantilever (SMC), and secondary cantilevers (SC). MC surrounds SMC and SC which have same dimension of 5600 x 800 x 10 μm3. The fabricated piezoelectric energy harvester can generate 51.4 mV(p-p) and 11 mV(p-p) of output voltages at 24.2 Hz and 33 Hz of its resonant frequencies by MC. Moreover, it can generate 8 mV(p-p) and 6.6 mV(p-p) of output voltages at 24.2 Hz and 33.2 Hz of its resonant frequencies by SMC; and 364 mV(p-p) of output voltage at 33.6 Hz of its resonant frequency by SC.

  12. Mechanisms of high-frequency song generation in brachypterous crickets and the role of ghost frequencies.

    PubMed

    Robillard, Tony; Montealegre-Z, Fernando; Desutter-Grandcolas, Laure; Grandcolas, Philippe; Robert, Daniel

    2013-06-01

    Sound production in crickets relies on stridulation, the well-understood rubbing together of a pair of specialised wings. As the file of one wing slides over the scraper of the other, a series of rhythmic impacts causes harmonic oscillations, usually resulting in the radiation of pure tones delivered at low frequencies (2-8 kHz). In the short-winged crickets of the Lebinthini tribe, acoustic communication relies on signals with remarkably high frequencies (>8 kHz) and rich harmonic content. Using several species of the subfamily Eneopterinae, we characterised the morphological and mechanical specialisations supporting the production of high frequencies, and demonstrated that higher harmonics are exploited as dominant frequencies. These specialisations affect the structure of the stridulatory file, the motor control of stridulation and the resonance of the sound radiator. We placed these specialisations in a phylogenetic framework and show that they serve to exploit high-frequency vibrational modes pre-existing in the phylogenetic ancestor. In Eneopterinae, the lower frequency components are harmonically related to the dominant peak, suggesting they are relicts of ancestral carrier frequencies. Yet, such ghost frequencies still occur in the wings' free resonances, highlighting the fundamental mechanical constraints of sound radiation. These results support the hypothesis that such high-frequency songs evolved stepwise, by a form of punctuated evolution that could be related to functional constraints, rather than by only the progressive increase of the ancestral fundamental frequency.

  13. The Effects of the Menstrual Cycle on Vibratory Characteristics of the Vocal Folds Investigated With High-Speed Digital Imaging.

    PubMed

    Kunduk, Melda; Vansant, Mathew B; Ikuma, Takeshi; McWhorter, Andrew

    2017-03-01

    This study investigated the effect of menstrual cycle on vocal fold vibratory characteristics in young women using high-speed digital imaging. This study examined the menstrual phase effect on five objective high-speed imaging parameters and two self-rated perceptual parameters. The effects of oral birth control use were also investigated. Thirteen subjects with no prior voice complaints were included in this study. All data were collected at three different time periods (premenses, postmenses, ovulation) over the course of one menstrual cycle. For five of the 13 subjects, data were collected for two consecutive cycles. Six of 13 subjects were oral birth control users. From high-speed imaging data, five objective parameters were computed: fundamental frequency, fundamental frequency deviation, harmonics-to-noise ratio, harmonic richness factor, and ratio of first and second harmonics. They were supplemented by two self-rated parameters: Reflux Severity Index and perceptual voice quality rating. Analysis included mixed model linear analysis with repeated measures. Results indicated no significant main effects for menstrual phase, between-cycle, or birth control use in the analysis for mean fundamental frequency, fundamental frequency deviation, harmonics-to-noise ratio, harmonic richness factor, first and second harmonics, Reflux Severity Index, and perceptual voice quality rating. Additionally, there were no interaction effects. Hormone fluctuations observed across the menstrual cycle do not appear to have direct effect on vocal fold vibratory characteristics in young women with no voice concerns. Birth control use, on the other hand, may have influence on spectral richness of vocal fold vibration. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  14. Pulse register phonation in Diana monkey alarm calls

    NASA Astrophysics Data System (ADS)

    Riede, Tobias; Zuberbühler, Klaus

    2003-05-01

    The adult male Diana monkeys (Cercopithecus diana) produce predator-specific alarm calls in response to two of their predators, the crowned eagles and the leopards. The acoustic structure of these alarm calls is remarkable for a number of theoretical and empirical reasons. First, although pulsed phonation has been described in a variety of mammalian vocalizations, very little is known about the underlying production mechanism. Second, Diana monkey alarm calls are based almost exclusively on this vocal production mechanism to an extent that has never been documented in mammalian vocal behavior. Finally, the Diana monkeys' pulsed phonation strongly resembles the pulse register in human speech, where fundamental frequency is mainly controlled by subglottal pressure. Here, we report the results of a detailed acoustic analysis to investigate the production mechanism of Diana monkey alarm calls. Within calls, we found a positive correlation between the fundamental frequency and the pulse amplitude, suggesting that both humans and monkeys control fundamental frequency by subglottal pressure. While in humans pulsed phonation is usually considered pathological or artificial, male Diana monkeys rely exclusively on pulsed phonation, suggesting a functional adaptation. Moreover, we were unable to document any nonlinear phenomena, despite the fact that they occur frequently in the vocal repertoire of humans and nonhumans, further suggesting that the very robust Diana monkey pulse production mechanism has evolved for a particular functional purpose. We discuss the implications of these findings for the structural evolution of Diana monkey alarm calls and suggest that the restricted variability in fundamental frequency and robustness of the source signal gave rise to the formant patterns observed in Diana monkey alarm calls, used to convey predator information.

  15. Fundamentals of dielectric properties measurements and agricultural applications.

    PubMed

    Nelson, Stuart O

    2010-01-01

    Dielectrics and dielectric properties are defined generally and dielectric measurement methods and equipment are described for various frequency ranges from audio frequencies through microwave frequencies. These include impedance and admittance bridges, resonant frequency, transmission-line, and free-space methods in the frequency domain and time-domain and broadband techniques. Many references are cited describing methods in detail and giving sources of dielectric properties data. Finally a few applications for such data are presented and sources of tabulated and dielectric properties data bases are identified.

  16. Guidelines for Selecting Microphones for Human Voice Production Research

    ERIC Educational Resources Information Center

    Svec, Jan G.; Granqvist, Svante

    2010-01-01

    Purpose: This tutorial addresses fundamental characteristics of microphones (frequency response, frequency range, dynamic range, and directionality), which are important for accurate measurements of voice and speech. Method: Technical and voice literature was reviewed and analyzed. The following recommendations on desirable microphone…

  17. A Fundamental Relationship Between Genotype Frequencies and Fitnesses

    PubMed Central

    Lachance, Joseph

    2008-01-01

    The set of possible postselection genotype frequencies in an infinite, randomly mating population is found. Geometric mean heterozygote frequency divided by geometric mean homozygote frequency equals two times the geometric mean heterozygote fitness divided by geometric mean homozygote fitness. The ratio of genotype frequencies provides a measure of genetic variation that is independent of allele frequencies. When this ratio does not equal two, either selection or population structure is present. Within-population HapMap data show population-specific patterns, while pooled data show an excess of homozygotes. PMID:18780726

  18. Suspension osteopenia in mice: Whole body electromagnetic field effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simske, S.J.; Luttges, M.W.

    1995-08-01

    Whole-body fields were tested for their efficacy in preventing the osteopenia caused by tail suspension in mice. The fields had fundamental frequencies corresponding to the upper range of predicted endogenous impact-generated frequencies (0.25--2.0 kHz) in the long bones. Three distinct whole-body EMFs were applied for 2 weeks on growing mice. Structural, geometric, and material properties of the femora, tibiae, and humeri of suspended mice were altered compared to controls. Comparison of suspended mice and mice subjected to caloric restriction indicates that the changes in caloric intake do not explain either the suspension or the field-induced effects. In agreement with pastmore » studies, rather, unloading appears to cause the suspension effects and to be addressed by the EMFs. The EMF effects on bone properties were apparently frequency dependent, with the lower two fundamental frequencies (260 and 910 Hz) altering, albeit slightly, the suspension-induced bone effects. The fields are not apparently optimized for frequency, etc., with respect to therapeutic potential; however, suspension provides a model system for further study of the in vivo effects of EMFs.« less

  19. Microstrip patch antenna for simultaneous strain and temperature sensing

    NASA Astrophysics Data System (ADS)

    Mbanya Tchafa, F.; Huang, H.

    2018-06-01

    A patch antenna, consisting of a radiation patch, a dielectric substrate, and a ground plane, resonates at distinct fundamental frequencies that depend on the substrate dielectric constant and the dimensions of the radiation patch. Since these parameters change with the applied strain and temperature, this study investigates simultaneous strain and temperature sensing using a single antenna that has two fundamental resonant frequencies. The theoretical relationship between the antenna resonant frequency shifts, the temperature, and the applied strain was first established to guide the selection of the dielectric substrate, based on which an antenna sensor with a rectangular radiation patch was designed and fabricated. A tensile test specimen instrumented with the antenna sensor was subjected to thermo-mechanical tests. Experiment results validated the theoretical predictions that the normalized antenna resonant frequency shifts are linearly proportional to the applied strain and temperature changes. An inverse method was developed to determine the strain and temperature changes from the normalized antenna resonant frequency shifts, yielding measurement uncertainty of 0.4 °C and 17.22 μ \\varepsilon for temperature and strain measurement, respectively.

  20. Suspension osteopenia in mice: whole body electromagnetic field effects.

    PubMed

    Simske, S J; Luttges, M W

    1995-01-01

    Whole-body fields were tested for their efficacy in preventing the osteopenia caused by tail suspension in mice. The fields had fundamental frequencies corresponding to the upper range of predicted endogenous impact-generated frequencies (0.25-2.0 kHz) in the long bones. Three distinct whole-body EMFs were applied for 2 weeks on growing mice. Structural, geometric, and material properties of the femora, tibiae, and humeri of suspended mice were altered compared to controls. Comparison of suspended mice and mice subjected to caloric restriction indicates that the changes in caloric intake do not explain either the suspension or the field-induced effects. In agreement with past studies, rather, unloading appears to cause the suspension effects and to be addressed by the EMFs. The EMF effects on bone properties were apparently frequency dependent, with the lower two fundamental frequencies (260 and 910 Hz) altering, albeit slightly, the suspension-induced bone effects. The fields are not apparently optimized for frequency, etc., with respect to therapeutic potential; however, suspension provides a model system for further study of the in vivo effects of EMFs.

  1. The natural frequencies of symmetric angle-ply laminates derived from eigensensitivity analysis

    NASA Technical Reports Server (NTRS)

    Reiss, Robert; Ramachandran, S.; Qian, BO

    1988-01-01

    In this paper, a new closed-form approximate solution for the natural frequencies of symmetric rectangular angle-ply laminates simply supported on all four edges is derived. The solution, obtained from eigensensitivity analysis, is expressed as a truncated Fourier series in the ply angle. Results show that the prediction for the fundamental frequency is quite accurate for engineering applications, often within 1-2 percent of the true frequency.

  2. Pressure sensitivity of flow oscillations in postocclusive reactive skin hyperemia.

    PubMed

    Strucl, M; Peterec, D; Finderle, Z; Maver, J

    1994-05-01

    Skin blood flow was monitored using a laser-Doppler (LD) flowmeter in 21 healthy volunteers after an occlusion of the digital arteries. The peripheral vascular bed was exposed to occlusion ischemia of varying duration (1, 4, or 8 min) and to a change in digital arterial pressure produced by different positions of the arm above heart level to characterize the pattern of LD flow oscillations in postocclusive reactive hyperemia (PRH) and to elucidate the relevance of metabolic and myogenic mechanisms in governing its fundamental frequency. The descending part of the hyperemic flow was characterized by the appearance of conspicuous periodic oscillations with a mean fundamental frequency of 7.2 +/- 1.5 cycles/min (SD, n = 9), as assessed by a Fourier transform frequency analysis of 50-s sections of flow. The mean respiratory frequency during the periods of flow frequency analysis was 17.0 +/- 2.2 (SD, n = 9), and the PRH oscillations remained during apnea in all tested subjects. The area under the maximum flow curve increased significantly with prolongation of the occlusion (paired t test, P < 0.001; n = 9), but showed no dependence on the estimated blood pressure in the digital arteries, which suggests the predominant role of a metabolic component in this part of the PRH response. In contrast, the fundamental frequency of PRH oscillations exhibited a significant decrease with a reduction in the estimated digital arterial pressure (linear regression, b = 0.08, P < 0.001; n = 12), but did not change with the prolongation of arterial occlusion despite a significant increase in mean LD flow (paired t test, P < 0.001; n = 9).(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Atomic clocks for geodesy.

    PubMed

    Mehlstäubler, Tanja E; Grosche, Gesine; Lisdat, Christian; Schmidt, Piet O; Denker, Heiner

    2018-06-01

    We review experimental progress on optical atomic clocks and frequency transfer, and consider the prospects of using these technologies for geodetic measurements. Today, optical atomic frequency standards have reached relative frequency inaccuracies below 10 -17 , opening new fields of fundamental and applied research. The dependence of atomic frequencies on the gravitational potential makes atomic clocks ideal candidates for the search for deviations in the predictions of Einstein's general relativity, tests of modern unifying theories and the development of new gravity field sensors. In this review, we introduce the concepts of optical atomic clocks and present the status of international clock development and comparison. Besides further improvement in stability and accuracy of today's best clocks, a large effort is put into increasing the reliability and technological readiness for applications outside of specialized laboratories with compact, portable devices. With relative frequency uncertainties of 10 -18 , comparisons of optical frequency standards are foreseen to contribute together with satellite and terrestrial data to the precise determination of fundamental height reference systems in geodesy with a resolution at the cm-level. The long-term stability of atomic standards will deliver excellent long-term height references for geodetic measurements and for the modelling and understanding of our Earth.

  4. A Discussion of Zero Spring Rate Mechanisms Used for the Active Isolation Mount Experiment

    NASA Technical Reports Server (NTRS)

    Teter, John E., Jr.

    1999-01-01

    In the summer of 1995 the Structural Dynamics Branch at NASA Langley Research Center set out to conceive a small, lightweight, low frequency isolation mount that could be used for spaceflight experiments. The Engineering Design Branch undertook the task of developing the isolation mount. This report describes the engineering process that led to three phases of a study entitled "Active Isolation Mounts" (AIM). A zero spring rate mechanism was used to achieve low fundamental frequencies for a payloads in the 1 to 10 pound range. It worked by balancing both a positive and a negative stiffness so that the net result was a small positive stiffness. The study demonstrated devices that could reduce the initial corner frequency by a factor of six for brief periods and a factor of two for extended periods. The designs were relatively simple and minimized weight, volume, and power. They could be scaled down and they were made of spaceflight compatible materials. All designs offered the ability to continuously vary the fundamental frequency. Yet, the goal of reducing the frequency by an order of magnitude was not achieved because the systems were too unstable at low frequencies. There was a trade between performance and stability.

  5. Atomic clocks for geodesy

    NASA Astrophysics Data System (ADS)

    Mehlstäubler, Tanja E.; Grosche, Gesine; Lisdat, Christian; Schmidt, Piet O.; Denker, Heiner

    2018-06-01

    We review experimental progress on optical atomic clocks and frequency transfer, and consider the prospects of using these technologies for geodetic measurements. Today, optical atomic frequency standards have reached relative frequency inaccuracies below 10‑17, opening new fields of fundamental and applied research. The dependence of atomic frequencies on the gravitational potential makes atomic clocks ideal candidates for the search for deviations in the predictions of Einstein’s general relativity, tests of modern unifying theories and the development of new gravity field sensors. In this review, we introduce the concepts of optical atomic clocks and present the status of international clock development and comparison. Besides further improvement in stability and accuracy of today’s best clocks, a large effort is put into increasing the reliability and technological readiness for applications outside of specialized laboratories with compact, portable devices. With relative frequency uncertainties of 10‑18, comparisons of optical frequency standards are foreseen to contribute together with satellite and terrestrial data to the precise determination of fundamental height reference systems in geodesy with a resolution at the cm-level. The long-term stability of atomic standards will deliver excellent long-term height references for geodetic measurements and for the modelling and understanding of our Earth.

  6. Broadband midinfrared frequency comb with tooth scanning

    NASA Astrophysics Data System (ADS)

    Lee, Kevin F.; Masłowski, P.; Mills, A.; Mohr, C.; Jiang, Jie; Schunemann, Peter G.; Fermann, M. E.

    2015-03-01

    Frequency combs are a massively parallel source of extremely accurate optical frequencies. Frequency combs generally operate at the visible or near-infrared wavelengths, but fundamental molecular vibrations occur at midinfrared wavelengths. We demonstrate an optically-referenced, broadband midinfrared frequency comb based on a doublyresonant optical parametric oscillator (OPO). By tuning the wavelength of the reference laser, the comb line frequencies are tuned as well. By scanning the reference wavelength, any frequency can be accessed, not just the frequencies of the base comb. Combined with our comb-resolving Fourier transform spectrometer, we can measure 200 wavenumber wide broadband absorption spectra with 200 kHz linewidth comb teeth. Our OPO is pumped by an amplified Tm fiber frequency comb, with phase-locked carrier envelope offset frequency, and repetition rate fixed by phase-locking a frequency comb line to a narrow linewidth diode laser at a telecom channel. The frequency comb is referenced to GPS by long-term stabilization of the repetition rate to a selected value using the temperature of the reference laser as the control. The resulting pump comb is about 3W of 100 fs pulses at 418 MHz repetition rate at 1950 nm. Part of the comb is used for supercontinuum generation for frequency stabilization, and the rest pumps an orientation-patterned gallium arsenide (OP-GaAs) crystal in a doubly-resonant optical parametric oscillator cavity, yielding collinear signal and idler beams from about 3 to 5.5 μm. We verify comb scanning by resolving the 200 MHz wide absorption lines of the entire fundamental CO vibrational manifold at 11 Torr pressure.

  7. Free Vibration of Uncertain Unsymmetrically Laminated Beams

    NASA Technical Reports Server (NTRS)

    Kapania, Rakesh K.; Goyal, Vijay K.

    2001-01-01

    Monte Carlo Simulation and Stochastic FEA are used to predict randomness in the free vibration response of thin unsymmetrically laminated beams. For the present study, it is assumed that randomness in the response is only caused by uncertainties in the ply orientations. The ply orientations may become random or uncertain during the manufacturing process. A new 16-dof beam element, based on the first-order shear deformation beam theory, is used to study the stochastic nature of the natural frequencies. Using variational principles, the element stiffness matrix and mass matrix are obtained through analytical integration. Using a random sequence a large data set is generated, containing possible random ply-orientations. This data is assumed to be symmetric. The stochastic-based finite element model for free vibrations predicts the relation between the randomness in fundamental natural frequencies and the randomness in ply-orientation. The sensitivity derivatives are calculated numerically through an exact formulation. The squared fundamental natural frequencies are expressed in terms of deterministic and probabilistic quantities, allowing to determine how sensitive they are to variations in ply angles. The predicted mean-valued fundamental natural frequency squared and the variance of the present model are in good agreement with Monte Carlo Simulation. Results, also, show that variations between plus or minus 5 degrees in ply-angles can affect free vibration response of unsymmetrically and symmetrically laminated beams.

  8. An Accurate ab initio Quartic Force Field and Vibrational Frequencies for CH4 and Isotopomers

    NASA Technical Reports Server (NTRS)

    Lee, Timothy J.; Martin, Jan M. L.; Taylor, Peter R.

    1995-01-01

    A very accurate ab initio quartic force field for CH4 and its isotopomers is presented. The quartic force field was determined with the singles and doubles coupled-cluster procedure that includes a quasiperturbative estimate of the effects of connected triple excitations, CCSD(T), using the correlation consistent polarized valence triple zeta, cc-pVTZ, basis set. Improved quadratic force constants were evaluated with the correlation consistent polarized valence quadruple zeta, cc-pVQZ, basis set. Fundamental vibrational frequencies are determined using second-order perturbation theory anharmonic analyses. All fundamentals of CH4 and isotopomers for which accurate experimental values exist and for which there is not a large Fermi resonance, are predicted to within +/- 6 cm(exp -1). It is thus concluded that our predictions for the harmonic frequencies and the anharmonic constants are the most accurate estimates available. It is also shown that using cubic and quartic force constants determined with the correlation consistent polarized double zeta, cc-pVDZ, basis set in conjunction with the cc-pVQZ quadratic force constants and equilibrium geometry leads to accurate predictions for the fundamental vibrational frequencies of methane, suggesting that this approach may be a viable alternative for larger molecules. Using CCSD(T), core correlation is found to reduce the CH4 r(e), by 0.0015 A. Our best estimate for r, is 1.0862 +/- 0.0005 A.

  9. Solar activity cycles: indication of the existence of fundamental symmetry?

    NASA Astrophysics Data System (ADS)

    Dreschhoff, Gisela; Wong, Kai Wai; Curatolo, Susana; Jungner, Hogne; Perry, Charles

    Previous work has shown that there is a consistent pattern that seems to be underlying the various known solar activity cycles, which is fundamentally based on the nuclear magnetic resonance frequencies (NMR) of some of the main isotopic constituents within the solar core, hydrogen-1 F(H-1)NMR and helium-3 F(He-3)NMR [1], and resulting in a so-called "beat-frequency", thereby suggesting that this mechanism may involve the entire Sun. Furthermore, it was found that the energy generating region of the Sun may be governed by an optimum condition where F(He-3)NMR = F(H-1)NMR associated with an internal magnetic field of 7 Gauss, and the beat-frequency Fbeat representing the Schwabe periodicity [2]. Using the Schwabe cycle as the basic cycle length (C2), the astronomical and geophysical data (solar activity cycles C1) are represented by a fundamental harmonic progression of the form C1 = C2 x 2n. We will attempt to show that this type of harmonic progression can be viewed as being part of fundamental principles of nature, as they are evident in the mathematical expression of 2n matrices in group representations SU(n), or the superposition of two states of one particle 21, two states of two (or n) particles leading to 22 (or 2n ) possible combinations. We may show that these fundamental principles are linked to the newly developed 5D projection field theory and the realization of matter as proposed by Wong [3]. [1] C.A. Perry, Thesis 1989, University of Kansas [2] G. Dreschhoff, Adv. Space Res., 40, p. 1015-1020, 2007 [3] K.W. Wong, Nova Science, 2009, in press

  10. Experimental and numerical investigation of tissue harmonic imaging (THI)

    NASA Astrophysics Data System (ADS)

    Jing, Yuan; Yang, Xinmai; Cleveland, Robin O.

    2003-04-01

    In THI the probing ultrasonic pulse has enough amplitude that it undergoes nonlinear distortion and energy shifts from the fundamental frequency of the pulse into its higher harmonics. Images generated from the second harmonic (SH) have superior quality to the images formed from the fundamental frequency. Experiments with a single element focused ultrasound transducer were used to compare a line target embedded in a tissue phantom using either fundamental or SH imaging. SH imaging showed an improvement in both the axial resolution (0.70 mm vs 0.92 mm) and the lateral resolution (1.02 mm vs 2.70 mm) of the target. In addition, the contrast-to-tissue ratio of the target was 2 dB higher with SH imaging. A three-dimensional model of the forward propagation has been developed to simulate the experimental system. The model is based on a time-domain code for solving the KZK equation and accounts for arbitrary spatial variations in all tissue properties. The code was used to determine the impact of a nearfield layer of fat on the fundamental and second harmonic signals. For a 15 mm thick layer the SH side-lobes remained the same but the fundamental side-lobes increased by 2 dB. [Work supported by the NSF through the Center for Subsurface Sensing and Imaging Systems.

  11. Caller sex and orientation influence spectral characteristics of "two-voice" stereotyped calls produced by free-ranging killer whales.

    PubMed

    Miller, Patrick J O; Samarra, Filipa I P; Perthuison, Aurélie D

    2007-06-01

    This study investigates how particular received spectral characteristics of stereotyped calls of sexually dimorphic adult killer whales may be influenced by caller sex, orientation, and range. Calls were ascribed to individuals during natural behavior using a towed beamforming array. The fundamental frequency of both high-frequency and low-frequency components did not differ consistently by sex. The ratio of peak energy within the fundamental of the high-frequency component relative to summed peak energy in the first two low-frequency component harmonics, and the number of modulation bands off the high-frequency component, were significantly greater when whales were oriented towards the array, while range and adult sex had little effect. In contrast, the ratio of peak energy in the first versus second harmonics of the low-frequency component was greater in calls produced by adult females than adult males, while orientation and range had little effect. The dispersion of energy across harmonics has been shown to relate to body size or sex in terrestrial species, but pressure effects during diving are thought to make such a signal unreliable in diving animals. The observed spectral differences by signaler sex and orientation suggest that these types of information may be transmitted acoustically by freely diving killer whales.

  12. Beeping and piping: characterization of two mechano-acoustic signals used by honey bees in swarming

    NASA Astrophysics Data System (ADS)

    Schlegel, Thomas; Visscher, P. Kirk; Seeley, Thomas D.

    2012-12-01

    Of the many signals used by honey bees during the process of swarming, two of them—the stop signal and the worker piping signal—are not easily distinguished for both are mechano-acoustic signals produced by scout bees who press their bodies against other bees while vibrating their wing muscles. To clarify the acoustic differences between these two signals, we recorded both signals from the same swarm and at the same time, and compared them in terms of signal duration, fundamental frequency, and frequency modulation. Stop signals and worker piping signals differ in all three variables: duration, 174 ± 64 vs. 602 ± 377 ms; fundamental frequency, 407 vs. 451 Hz; and frequency modulation, absent vs. present. While it remains unclear which differences the bees use to distinguish the two signals, it is clear that they do so for the signals have opposite effects. Stop signals cause inhibition of actively dancing scout bees whereas piping signals cause excitation of quietly resting non-scout bees.

  13. Fundamental frequencies and resonances from eccentric and precessing binary black hole inspirals

    NASA Astrophysics Data System (ADS)

    Lewis, Adam G. M.; Zimmerman, Aaron; Pfeiffer, Harald P.

    2017-06-01

    Binary black holes which are both eccentric and undergo precession remain unexplored in numerical simulations. We present simulations of such systems which cover about 50 orbits at comparatively high mass ratios 5 and 7. The configurations correspond to the generic motion of a nonspinning body in a Kerr spacetime, and are chosen to study the transition from finite mass-ratio inspirals to point particle motion in Kerr. We develop techniques to extract analogs of the three fundamental frequencies of Kerr geodesics, compare our frequencies to those of Kerr, and show that the differences are consistent with self-force corrections entering at first order in mass ratio. This analysis also locates orbital resonances where the ratios of our frequencies take rational values. At the considered mass ratios, the binaries pass through resonances in one to two resonant cycles, and we find no discernible effects on the orbital evolution. We also compute the decay of eccentricity during the inspiral and find good agreement with the leading order post-Newtonian prediction.

  14. Synthesis of laughter by modifying excitation characteristics.

    PubMed

    Thati, Sathya Adithya; Kumar K, Sudheer; Yegnanarayana, B

    2013-05-01

    In this paper, a method to synthesize laughter by modifying the excitation source information is presented. The excitation source information is derived by extracting epoch locations and instantaneous fundamental frequency using zero frequency filtering approach. The zero frequency filtering approach is modified to capture the rapidly varying instantaneous fundamental frequency in natural laugh signals. The nature of variation of excitation features in natural laughter is examined to determine the features to be incorporated in the synthesis of a laugh signal. Features such as pitch period and strength of excitation are modified in the utterance of vowel /a/ or /i/ to generate the laughter signal. Frication is also incorporated wherever appropriate. Laugh signal is generated by varying parameters at both call level and bout level. Experiments are conducted to determine the significance of different features in the perception of laughter. Subjective evaluation is performed to determine the level of acceptance and quality of synthesis of the synthesized laughter signal for different choices of parameter values and for different input types.

  15. Neuromuscular control of fundamental frequency and glottal posture at phonation onset

    PubMed Central

    Chhetri, Dinesh K.; Neubauer, Juergen; Berry, David A.

    2012-01-01

    The laryngeal neuromuscular mechanisms for modulating glottal posture and fundamental frequency are of interest in understanding normal laryngeal physiology and treating vocal pathology. The intrinsic laryngeal muscles in an in vivo canine model were electrically activated in a graded fashion to investigate their effects on onset frequency, phonation onset pressure, vocal fold strain, and glottal distance at the vocal processes. Muscle activation plots for these laryngeal parameters were evaluated for the interaction of following pairs of muscle activation conditions: (1) cricothyroid (CT) versus all laryngeal adductors (TA/LCA/IA), (2) CT versus LCA/IA, (3) CT versus thyroarytenoid (TA) and, (4) TA versus LCA/IA (LCA: lateral cricoarytenoid muscle, IA: interarytenoid). Increases in onset frequency and strain were primarily affected by CT activation. Onset pressure correlated with activation of all adductors in activation condition 1, but primarily with CT activation in conditions 2 and 3. TA and CT were antagonistic for strain. LCA/IA activation primarily closed the cartilaginous glottis while TA activation closed the mid-membranous glottis. PMID:22352513

  16. Sexual selection on male vocal fundamental frequency in humans and other anthropoids.

    PubMed

    Puts, David A; Hill, Alexander K; Bailey, Drew H; Walker, Robert S; Rendall, Drew; Wheatley, John R; Welling, Lisa L M; Dawood, Khytam; Cárdenas, Rodrigo; Burriss, Robert P; Jablonski, Nina G; Shriver, Mark D; Weiss, Daniel; Lameira, Adriano R; Apicella, Coren L; Owren, Michael J; Barelli, Claudia; Glenn, Mary E; Ramos-Fernandez, Gabriel

    2016-04-27

    In many primates, including humans, the vocalizations of males and females differ dramatically, with male vocalizations and vocal anatomy often seeming to exaggerate apparent body size. These traits may be favoured by sexual selection because low-frequency male vocalizations intimidate rivals and/or attract females, but this hypothesis has not been systematically tested across primates, nor is it clear why competitors and potential mates should attend to vocalization frequencies. Here we show across anthropoids that sexual dimorphism in fundamental frequency (F0) increased during evolutionary transitions towards polygyny, and decreased during transitions towards monogamy. Surprisingly, humans exhibit greater F0 sexual dimorphism than any other ape. We also show that low-F0 vocalizations predict perceptions of men's dominance and attractiveness, and predict hormone profiles (low cortisol and high testosterone) related to immune function. These results suggest that low male F0 signals condition to competitors and mates, and evolved in male anthropoids in response to the intensity of mating competition. © 2016 The Author(s).

  17. Cortical contributions to the auditory frequency-following response revealed by MEG

    PubMed Central

    Coffey, Emily B. J.; Herholz, Sibylle C.; Chepesiuk, Alexander M. P.; Baillet, Sylvain; Zatorre, Robert J.

    2016-01-01

    The auditory frequency-following response (FFR) to complex periodic sounds is used to study the subcortical auditory system, and has been proposed as a biomarker for disorders that feature abnormal sound processing. Despite its value in fundamental and clinical research, the neural origins of the FFR are unclear. Using magnetoencephalography, we observe a strong, right-asymmetric contribution to the FFR from the human auditory cortex at the fundamental frequency of the stimulus, in addition to signal from cochlear nucleus, inferior colliculus and medial geniculate. This finding is highly relevant for our understanding of plasticity and pathology in the auditory system, as well as higher-level cognition such as speech and music processing. It suggests that previous interpretations of the FFR may need re-examination using methods that allow for source separation. PMID:27009409

  18. Tunable sub-gap radiation detection with superconducting resonators

    NASA Astrophysics Data System (ADS)

    Dupré, O.; Benoît, A.; Calvo, M.; Catalano, A.; Goupy, J.; Hoarau, C.; Klein, T.; Le Calvez, K.; Sacépé, B.; Monfardini, A.; Levy-Bertrand, F.

    2017-04-01

    We have fabricated planar amorphous indium oxide superconducting resonators ({T}{{c}}˜ 2.8 K) that are sensitive to frequency-selective radiation in the range of 7-10 GHz. Those values lay far below twice the superconducting gap that is worth about 200 GHz. The photon detection consists in a shift of the fundamental resonance frequency. We show that the detected frequency can be adjusted by modulating the total length of the superconducting resonator. We attribute those observations to the excitation of higher-order resonance modes. The coupling between the fundamental lumped and the higher order distributed resonance is due to the kinetic inductance nonlinearity with current. These devices, that we have called sub-gap kinetic inductance detectors, are to be distinguished from the standard kinetic inductance detectors in which quasi-particles are generated when incident light breaks down Cooper pairs.

  19. High efficiency and output power from second- and third-harmonic millimeter-wave InP-TED oscillators at frequencies above 170 GHz

    NASA Astrophysics Data System (ADS)

    Rydberg, Anders

    1990-10-01

    InP TED (transferred electron device) oscillators have been experimentally investigated for frequencies between 170 and 279 GHz. It has been found that output powers of more than 7 and 0.2 mW are possible at 180 and 272 GHz using second- and third-harmonic mode operation, respectively. Conversion efficiencies of more than 13 percent and 0.3 percent between fundamental and second harmonic and fundamental and third harmonic, respectively, have been found. The conversion efficiencies are comparable to GaAs TEDs. The output powers, conversion efficiencies, and tuning ranges (more than 22 percent) are the largest reported for InP TEDs at these frequencies. The output power at third harmonic was sufficient for supplying a superconducting mixer with local oscillator power.

  20. Harmonic mode-locking using the double interval technique in quantum dot lasers.

    PubMed

    Li, Yan; Chiragh, Furqan L; Xin, Yong-Chun; Lin, Chang-Yi; Kim, Junghoon; Christodoulou, Christos G; Lester, Luke F

    2010-07-05

    Passive harmonic mode-locking in a quantum dot laser is realized using the double interval technique, which uses two separate absorbers to stimulate a specific higher-order repetition rate compared to the fundamental. Operating alone these absorbers would otherwise reinforce lower harmonic frequencies, but by operating together they produce the harmonic corresponding to their least common multiple. Mode-locking at a nominal 60 GHz repetition rate, which is the 10(th) harmonic of the fundamental frequency of the device, is achieved unambiguously despite the constraint of a uniformly-segmented, multi-section device layout. The diversity of repetition rates available with this method is also discussed.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yashchuk, Valeriy V; Conley, Raymond; Anderson, Erik H.

    We discuss the results of SEM and TEM measurements with the BPRML test samples fabricated from a BPRML (WSi2/Si with fundamental layer thickness of 3 nm) with a Dual Beam FIB (focused ion beam)/SEM technique. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-raymore » microscopes. Corresponding work with x-ray microscopes is in progress.« less

  2. Testing Fundamental Properties of Space with the Fermilab Holometer

    DOE PAGES

    Kamai, Brittany

    2017-06-01

    Precision length measurements provide valuable insights about the fundamental properties of space-time. The Holometer is a research program to both experimentally probe signatures of the Planck scale and to extend the accessible frequency range from kHz up to MHz for gravitational wave searches. The instrument consists of separate yet identical 39-meter Michelson interferometers operated at Fermi National Accelerator Laboratory, which can reach length sensitivities better thanmore » $${10}^{-20}\\mathrm{m/}\\sqrt{\\mathrm{Hz}}$$ within the 1-10 MHz frequency range. Lastly, the Holometer is fully operational with 130 of hours of science quality data obtained during the first observational campaign.« less

  3. Interspecific variation of warning calls in piranhas: a comparative analysis.

    PubMed

    Mélotte, Geoffrey; Vigouroux, Régis; Michel, Christian; Parmentier, Eric

    2016-10-26

    Fish sounds are known to be species-specific, possessing unique temporal and spectral features. We have recorded and compared sounds in eight piranha species to evaluate the potential role of acoustic communication as a driving force in clade diversification. All piranha species showed the same kind of sound-producing mechanism: sonic muscles originate on vertebrae and attach to a tendon surrounding the bladder ventrally. Contractions of the sound-producing muscles force swimbladder vibration and dictate the fundamental frequency. It results the calling features of the eight piranha species logically share many common characteristics. In all the species, the calls are harmonic sounds composed of multiple continuous cycles. However, the sounds of Serrasalmus elongatus (higher number of cycles and high fundamental frequency) and S. manueli (long cycle periods and low fundamental frequency) are clearly distinguishable from the other species. The sonic mechanism being largely conserved throughout piranha evolution, acoustic communication can hardly be considered as the main driving force in the diversification process. However, sounds of some species are clearly distinguishable despite the short space for variations supporting the need for specific communication. Behavioural studies are needed to clearly understand the eventual role of the calls during spawning events.

  4. HUMAN SPEECH: A RESTRICTED USE OF THE MAMMALIAN LARYNX

    PubMed Central

    Titze, Ingo R.

    2016-01-01

    Purpose Speech has been hailed as unique to human evolution. While the inventory of distinct sounds producible with vocal tract articulators is a great advantage in human oral communication, it is argued here that the larynx as a sound source in speech is limited in its range and capability because a low fundamental frequency is ideal for phonemic intelligibility and source-filter independence. Method Four existing data sets were combined to make an argument regarding exclusive use of the larynx for speech: (1) range of fundamental frequency, (2) laryngeal muscle activation, (3) vocal fold length in relation to sarcomere length of the major laryngeal muscles, and (4) vocal fold morphological development. Results Limited data support the notion that speech tends to produce a contracture of the larynx. The morphological design of the human vocal folds, like that of primates and other mammals, is optimized for vocal communication over distances for which higher fundamental frequency, higher intensity, and fewer unvoiced segments are utilized than in conversational speech. Conclusion The positive message is that raising one’s voice to call, shout, or sing, or executing pitch glides to stretch the vocal folds, can counteract this trend toward a contracted state. PMID:27397113

  5. Spectral analysis of unsteady surface pressure on a pusher propeller

    NASA Technical Reports Server (NTRS)

    Farokhi, Saeed

    1992-01-01

    A propeller of an advanced turboprop testbed aircraft in pusher configuration is instrumented with 22 miniature blade-mounted transducers (BMTs) at two radii. Upstream pylon wake interaction with the propeller is the source of a one-per-cycle excitation for the blades in flight. The time history of fluctuating pressure signals over 26 flight conditions is statistically analyzed in the frequency domain. The rms amplitude of fluctuating pressure signals measured by suction surface BMTs indicates a very strong presence of the fundamental frequency over most of the upper surface. The pylon wake pressure signature on the propeller trailing edge, i.e., x/c not less than 0.80, shows predominantly random turbulence; hence, the amplitude of the fundamental frequency wave is fairly small. The resurgence of a large amplitude fundamental harmonic with coherent pylon wake signature further downstream, say at 90 percent chord, is unexpected behavior. The appearance of a dominating second propeller shaft order in the spectra of the rms pressure in transonic flight conditions identifies the presence of a two-per-cycle excitation source in the azimuthal direction. This is due to the presence of a shock wave, as evidenced by the pressure-time history plots.

  6. Cause-effect relationship between vocal fold physiology and voice production in a three-dimensional phonation model

    PubMed Central

    Zhang, Zhaoyan

    2016-01-01

    The goal of this study is to better understand the cause-effect relation between vocal fold physiology and the resulting vibration pattern and voice acoustics. Using a three-dimensional continuum model of phonation, the effects of changes in vocal fold stiffness, medial surface thickness in the vertical direction, resting glottal opening, and subglottal pressure on vocal fold vibration and different acoustic measures are investigated. The results show that the medial surface thickness has dominant effects on the vertical phase difference between the upper and lower margins of the medial surface, closed quotient, H1-H2, and higher-order harmonics excitation. The main effects of vocal fold approximation or decreasing resting glottal opening are to lower the phonation threshold pressure, reduce noise production, and increase the fundamental frequency. Increasing subglottal pressure is primarily responsible for vocal intensity increase but also leads to significant increase in noise production and an increased fundamental frequency. Increasing AP stiffness significantly increases the fundamental frequency and slightly reduces noise production. The interaction among vocal fold thickness, stiffness, approximation, and subglottal pressure in the control of F0, vocal intensity, and voice quality is discussed. PMID:27106298

  7. Interspecific variation of warning calls in piranhas: a comparative analysis

    PubMed Central

    Mélotte, Geoffrey; Vigouroux, Régis; Michel, Christian; Parmentier, Eric

    2016-01-01

    Fish sounds are known to be species-specific, possessing unique temporal and spectral features. We have recorded and compared sounds in eight piranha species to evaluate the potential role of acoustic communication as a driving force in clade diversification. All piranha species showed the same kind of sound-producing mechanism: sonic muscles originate on vertebrae and attach to a tendon surrounding the bladder ventrally. Contractions of the sound-producing muscles force swimbladder vibration and dictate the fundamental frequency. It results the calling features of the eight piranha species logically share many common characteristics. In all the species, the calls are harmonic sounds composed of multiple continuous cycles. However, the sounds of Serrasalmus elongatus (higher number of cycles and high fundamental frequency) and S. manueli (long cycle periods and low fundamental frequency) are clearly distinguishable from the other species. The sonic mechanism being largely conserved throughout piranha evolution, acoustic communication can hardly be considered as the main driving force in the diversification process. However, sounds of some species are clearly distinguishable despite the short space for variations supporting the need for specific communication. Behavioural studies are needed to clearly understand the eventual role of the calls during spawning events. PMID:27782184

  8. Detecting vocal fatigue in student singers using acoustic measures of mean fundamental frequency, jitter, shimmer, and harmonics-to-noise ratio

    NASA Astrophysics Data System (ADS)

    Sisakun, Siphan

    2000-12-01

    The purpose of this study is to explore the ability of four acoustic parameters, mean fundamental frequency, jitter, shimmer, and harmonics-to-noise ratio, to detect vocal fatigue in student singers. The participants are 15 voice students, who perform two distinct tasks, data collection task and vocal fatiguing task. The data collection task includes the sustained vowel /a/, reading a standard passage, and self-rate on a vocal fatigue form. The vocal fatiguing task is the vocal practice of musical scores for a total of 45 minutes. The four acoustic parameters are extracted using the software EZVoicePlus. The data analyses are performed to answer eight research questions. The first four questions relate to correlations of the self-rating scale and each of the four parameters. The next four research questions relate to differences in the parameters over time using one-factor repeated measures analysis of variance (ANOVA). The result yields a proposed acoustic profile of vocal fatigue in student singers. This profile is characterized by increased fundamental frequency; slightly decreased jitter; slightly decreased shimmer; and slightly increased harmonics-to-noise ratio. The proposed profile requires further investigation.

  9. Oscillatory brain responses in spoken word production reflect lexical frequency and sentential constraint.

    PubMed

    Piai, Vitória; Roelofs, Ardi; Maris, Eric

    2014-01-01

    Two fundamental factors affecting the speed of spoken word production are lexical frequency and sentential constraint, but little is known about their timing and electrophysiological basis. In the present study, we investigated event-related potentials (ERPs) and oscillatory brain responses induced by these factors, using a task in which participants named pictures after reading sentences. Sentence contexts were either constraining or nonconstraining towards the final word, which was presented as a picture. Picture names varied in their frequency of occurrence in the language. Naming latencies and electrophysiological responses were examined as a function of context and lexical frequency. Lexical frequency is an index of our cumulative learning experience with words, so lexical-frequency effects most likely reflect access to memory representations for words. Pictures were named faster with constraining than nonconstraining contexts. Associated with this effect, starting around 400 ms pre-picture presentation, oscillatory power between 8 and 30 Hz was lower for constraining relative to nonconstraining contexts. Furthermore, pictures were named faster with high-frequency than low-frequency names, but only for nonconstraining contexts, suggesting differential ease of memory access as a function of sentential context. Associated with the lexical-frequency effect, starting around 500 ms pre-picture presentation, oscillatory power between 4 and 10 Hz was higher for high-frequency than for low-frequency names, but only for constraining contexts. Our results characterise electrophysiological responses associated with lexical frequency and sentential constraint in spoken word production, and point to new avenues for studying these fundamental factors in language production. © 2013 Published by Elsevier Ltd.

  10. Unusually high-pitched neonate distress calls of the open-habitat Mongolian gazelle ( Procapra gutturosa) and their anatomical and hormonal predictors

    NASA Astrophysics Data System (ADS)

    Volodin, Ilya A.; Volodina, Elena V.; Frey, Roland; Kirilyuk, Vadim E.; Naidenko, Sergey V.

    2017-06-01

    In neonate ruminants, the acoustic structure of vocalizations may depend on sex, vocal anatomy, hormonal profiles and body mass and on environmental factors. In neonate wild-living Mongolian gazelles Procapra gutturosa, hand-captured during biomedical monitoring in the Daurian steppes at the Russian-Mongolian border, we spectrographically analysed distress calls and measured body mass of 22 individuals (6 males, 16 females). For 20 (5 male, 15 female) of these individuals, serum testosterone levels were also analysed. In addition, we measured relevant dimensions of the vocal apparatus (larynx, vocal folds, vocal tract) in one stillborn male Mongolian gazelle specimen. Neonate distress calls of either sex were high in maximum fundamental frequency (800-900 Hz), but the beginning and minimum fundamental frequencies were significantly lower in males than in females. Body mass was larger in males than in females. The levels of serum testosterone were marginally higher in males. No correlations were found between either body mass or serum testosterone values and any acoustic variable for males and females analysed together or separately. We discuss that the high-frequency calls of neonate Mongolian gazelles are more typical for closed-habitat neonate ruminants, whereas other open-habitat neonate ruminants (goitred gazelle Gazella subgutturosa, saiga antelope Saiga tatarica and reindeer Rangifer tarandus) produce low-frequency (<200 Hz) distress calls. Proximate cause for the high fundamental frequency of distress calls of neonate Mongolian gazelles is their very short, atypical vocal folds (4 mm) compared to the 7-mm vocal folds of neonate goitred gazelles, producing distress calls as low as 120 Hz.

  11. Methodology for Selection of Optimum Light Stringers in Functionally Graded Panels Designed for Prescribed Fundamental Frequency or Buckling Load

    NASA Astrophysics Data System (ADS)

    Birman, Victor; Byrd, Larry W.

    2008-02-01

    The interest to functionally graded materials (FGM) and structures has been generated by their potential advantages, including enhanced thermal properties, reduced or eliminated delamination concerns, a potential for an improved stress distribution, etc. Various aspects of the processing, design, micromechanics and analysis of FGM have been outlined in a number of reviews, mentioned here are [1-3]. In particular, functionally graded panels may be advantageous compared to their conventional counterparts in numerous applications. However, a typical FGM panel is asymmetric about its middle plane resulting in lower buckling loads and fundamental frequencies as well as higher stresses and deformations than the counterpart with a symmetric distribution of the same constituents. The reduced stiffness of FGM panels can be compensated by reinforcing them with stringers. For example, metallic stringers at the metal-rich surface of a FGM ceramic-metal panel may provide an efficient solution enabling a designer to increase both buckling loads as well as natural frequencies. The list of studies on optimization of FGM is extensive as could be anticipated for such tailored structural elements. For example, recent papers by Batra and his collaborators present optimization of the natural frequencies of a FGM plate through material grading [4] and through the graded fiber orientation [5]. The present paper is concerned with an optimum design of the system of stringers for a specified FGM panel. The task is to design the lightest system of stringers enabling the panel to achieve prescribed buckling loads or fundamental frequency.

  12. Hadamard-Encoded Multipulses for Contrast-Enhanced Ultrasound Imaging.

    PubMed

    Gong, Ping; Song, Pengfei; Chen, Shigao

    2017-11-01

    The development of contrast-enhanced ultrasound (CEUS) imaging offers great opportunities for new ultrasound clinical applications such as myocardial perfusion imaging and abdominal lesion characterization. In CEUS imaging, the contrast agents (i.e., microbubbles) are utilized to improve the contrast between blood and tissue based on their high nonlinearity under low ultrasound pressure. In this paper, we propose a new CEUS pulse sequence by combining Hadamard-encoded multipulses (HEM) with fundamental frequency bandpass filter (i.e., filter centered on transmit frequency). HEM consecutively emits multipulses encoded by a second-order Hadamard matrix in each of the two transmission events (i.e., pulse-echo events), as opposed to conventional CEUS methods which emit individual pulses in two separate transmission events (i.e., pulse inversion (PI), amplitude modulation (AM), and PIAM). In HEM imaging, the microbubble responses can be improved by the longer transmit pulse, and the tissue harmonics can be suppressed by the fundamental frequency filter, leading to significantly improved contrast-to-tissue ratio (CTR) and signal-to-noise ratio (SNR). In addition, the fast polarity change between consecutive coded pulse emissions excites strong nonlinear microbubble echoes, further enhancing the CEUS image quality. The spatial resolution of HEM image is compromised as compared to other microbubble imaging methods due to the longer transmit pulses and the lower imaging frequency (i.e., fundamental frequency). However, the resolution loss was shown to be negligible and could be offset by the significantly enhanced CTR, SNR, and penetration depth. These properties of HEM can potentially facilitate robust CEUS imaging for many clinical applications, especially for deep abdominal organs and heart.

  13. Spatial-frequency spectrum of patterns changes the visibility of spatial-phase differences

    NASA Technical Reports Server (NTRS)

    Lawton, T. B.

    1985-01-01

    It is shown that spatial-frequency components over a 4-octave range affected the visibility of spatial-phase differences. Contrast thresholds were measured for discrimination between two (+45- and -45-deg) spatial phases of a sinusoidal test grating added to a background grating. The background could contain one or several sinusoidal components, all in 0-deg phase. Phase differences between the test and the background were visible at lower contrasts when test and background frequencies were harmonically related than when they were not, when test and background frequencies were within 1 octave than when they were farther apart, when the fundamental frequency of the background was low than when it was high, and for some discriminations more than for others, after practice. The visibility of phase differences was not affected by additional components in the background if the fundamental and difference frequencies of the background remained unchanged. Observers' reports of their strategies gave information about the types of attentive processing that were used to discriminate phase differences. Attentive processing facilitated phase discrimination for multifrequency gratings spanning a much wider range of spatial frequencies than would be possible by using only local preattentive processing. These results were consistent with the visibility of phase differences being processed by some combination of even- and odd-symmetric simple cells tuned to a wide range of different spatial frequencies.

  14. 47 CFR 15.207 - Conducted limits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... apply to carrier current systems operating as intentional radiators on frequencies below 30 MHz. In lieu... current system containing their fundamental emission within the frequency band 535-1705 kHz and intended.../50 ohms LISN. (3) Carrier current systems operating below 30 MHz are also subject to the radiated...

  15. Enhanced vasomotion of cerebral arterioles in spontaneously hypertensive rats

    NASA Technical Reports Server (NTRS)

    Lefer, D. J.; Lynch, C. D.; Lapinski, K. C.; Hutchins, P. M.

    1990-01-01

    Intrinsic rhythmic changes in the diameter of pial cerebral arterioles (30-70 microns) in anesthetized normotensive and hypertensive rats were assessed in vivo to determine if any significant differences exist between the two strains. All diameter measurements were analyzed using a traditional graphic analysis technique and a new frequency spectrum analysis technique known as the Prony Spectral Line Estimator. Graphic analysis of the data revealed that spontaneously hypertensive rats (SHR) possess a significantly greater fundamental frequency (5.57 +/- 0.28 cycles/min) of vasomotion compared to the control Wistar-Kyoto normotensive rats (WKY) (1.95 +/- 0.37 cycles/min). Furthermore, the SHR cerebral arterioles exhibited a significantly greater amplitude of vasomotion (10.07 +/- 0.70 microns) when compared to the WKY cerebral arterioles of the same diameter (8.10 +/- 0.70 microns). Diameter measurements processed with the Prony technique revealed that the fundamental frequency of vasomotion in SHR cerebral arterioles (6.14 +/- 0.39 cycles/min) was also significantly greater than that of the WKY cerebral arterioles (2.99 +/- 0.42 cycles/min). The mean amplitudes of vasomotion in the SHR and WKY strains obtained by the Prony analysis were found not to be statistically significant in contrast to the graphic analysis of the vasomotion amplitude of the arterioles. In addition, the Prony system was able to consistently uncover a very low frequency of vasomotion in both strains of rats that was typically less than 1 cycle/min and was not significantly different between the two strains. The amplitude of this slow frequency was also not significantly different between the two strains. The amplitude of the slow frequency of vasomotion (less than 1 cycle/min) was not different from the amplitude of the higher frequency (2-6 cycles/min) vasomotion by Prony or graphic analysis. These data suggest that a fundamental intrinsic defect exists in the spontaneously hypertensive rat that may contribute to the pathogenesis of hypertension in these animals.

  16. The MACHO Project Large Magellanic Cloud Variable-Star Inventory. IX. Frequency Analysis of the First-Overtone RR Lyrae Stars and the Indication for Nonradial Pulsations

    NASA Astrophysics Data System (ADS)

    Alcock, C.; Allsman, R.; Alves, D. R.; Axelrod, T.; Becker, A.; Bennett, D.; Clement, C.; Cook, K. H.; Drake, A.; Freeman, K.; Geha, M.; Griest, K.; Kovács, G.; Kurtz, D. W.; Lehner, M.; Marshall, S.; Minniti, D.; Nelson, C.; Peterson, B.; Popowski, P.; Pratt, M.; Quinn, P.; Rodgers, A.; Rowe, J.; Stubbs, C.; Sutherland, W.; Tomaney, A.; Vandehei, T.; Welch, D. L.

    2000-10-01

    More than 1300 variables classified provisionally as first-overtone RR Lyrae pulsators in the MACHO variable-star database of the Large Magellanic Cloud (LMC) have been subjected to standard frequency analysis. Based on the remnant power in the prewhitened spectra, we found 70% of the total population to be monoperiodic. The remaining 30% (411 stars) are classified as one of nine types according to their frequency spectra. Several types of RR Lyrae pulsational behavior are clearly identified here for the first time. Together with the earlier discovered double-mode (fundamental and first-overtone) variables, this study increased the number of known double-mode stars in the LMC to 181. During the total 6.5 yr time span of the data, 10% of the stars showed strong period changes. The size, and in general also the patterns of the period changes, exclude a simple evolutionary explanation. We also discovered two additional types of multifrequency pulsators with low occurrence rates of 2% for each. In the first type, there remains one closely spaced component after prewhitening by the main pulsation frequency. In the second type, the number of remnant components is two; they are also closely spaced, and are symmetric in their frequency spacing relative to the central component. This latter type of variables are associated with their relatives among the fundamental pulsators, known as Blazhko variables. Their high frequency (~20%) among the fundamental-mode variables versus the low occurrence rate of their first-overtone counterparts makes it more difficult to explain the Blazhko phenomenon by any theory depending mainly on the role of aspect angle or magnetic field. None of the current theoretical models are able to explain the observed close frequency components without invoking nonradial pulsation components in these stars.

  17. Nanoelectromechanical systems: Nanodevice motion at microwave frequencies

    NASA Astrophysics Data System (ADS)

    Henry Huang, Xue Ming; Zorman, Christian A.; Mehregany, Mehran; Roukes, Michael L.

    2003-01-01

    It has been almost forgotten that the first computers envisaged by Charles Babbage in the early 1800s were mechanical and not electronic, but the development of high-frequency nanoelectromechanical systems is now promising a range of new applications, including sensitive mechanical charge detectors and mechanical devices for high-frequency signal processing, biological imaging and quantum measurement. Here we describe the construction of nanodevices that will operate with fundamental frequencies in the previously inaccessible microwave range (greater than 1 gigahertz). This achievement represents a significant advance in the quest for extremely high-frequency nanoelectromechanical systems.

  18. On Frequency Combs in Monolithic Resonators

    NASA Astrophysics Data System (ADS)

    Savchenkov, A. A.; Matsko, A. B.; Maleki, L.

    2016-06-01

    Optical frequency combs have become indispensable in astronomical measurements, biological fingerprinting, optical metrology, and radio frequency photonic signal generation. Recently demonstrated microring resonator-based Kerr frequency combs point the way towards chip scale optical frequency comb generator retaining major properties of the lab scale devices. This technique is promising for integrated miniature radiofrequency and microwave sources, atomic clocks, optical references and femtosecond pulse generators. Here we present Kerr frequency comb development in a historical perspective emphasizing its similarities and differences with other physical phenomena. We elucidate fundamental principles and describe practical implementations of Kerr comb oscillators, highlighting associated solved and unsolved problems.

  19. Visuomotor Tracking Ability of Young Adult Speakers.

    ERIC Educational Resources Information Center

    Moon, Jerald B.; And Others

    1993-01-01

    Twenty-five normal young adult speakers tracked sinusoidal and unpredictable target signals using lower lip and jaw movement and fundamental frequency modulation. Tracking accuracy varied as a function of target frequency and articulator used to track. Results show the potential of visuomotor tracking tasks in the assessment of speech articulatory…

  20. Differences in Word Recognition between Early Bilinguals and Monolinguals: Behavioral and ERP Evidence

    ERIC Educational Resources Information Center

    Lehtonen, Minna; Hulten, Annika; Rodriguez-Fornells, Antoni; Cunillera, Toni; Tuomainen, Jyrki; Laine, Matti

    2012-01-01

    We investigated the behavioral and brain responses (ERPs) of bilingual word recognition to three fundamental psycholinguistic factors, frequency, morphology, and lexicality, in early bilinguals vs. monolinguals. Earlier behavioral studies have reported larger frequency effects in bilinguals' nondominant vs. dominant language and in some studies…

  1. 47 CFR 15.107 - Conducted limits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... not apply to carrier current systems operating as unintentional radiators on frequencies below 30 MHz... carrier current systems containing their fundamental emission within the frequency band 535-1705 kHz and... 50 μH/50 ohms LISN. (3) Carrier current systems operating below 30 MHz are also subject to the...

  2. Identification of Natural Frequency of Low Rise Building on Soft Ground Profile using Ambient Vibration Method

    NASA Astrophysics Data System (ADS)

    Kamarudin, A. F.; Zainal Abidin, M. H.; Mokhatar, S. N.; Daud, M. E.; Ibrahim, A.; Ibrahim, Z.; Noh, M. S. Md

    2018-04-01

    Natural frequency is the rate at which a body to vibrate or oscillate. Application of ambient vibration (AV) excitation is widely used nowadays as the input motion for building predominant frequency, fo, and ground fundamental frequency, Fo, prediction due to simple, fast, non-destructive, simple handling operation and reliable result. However, it must be emphasized and caution to isolate these frequencies (fo and Fo) from spurious frequencies of site-structure effects especially to low rise building on soft ground deposit. In this study, identification of fo and Fo by using AV measurements were performed on ground and 4-storey primary school reinforced concrete (RC) building at Sekolah Kebangsaan (SK) Sg. Tongkang, Rengit, Johor using 1 Hz of tri-axial seismometer sensor. Overlapping spectra between Fourier Amplitude Spectra (FAS) from and Horizontal to Vertical Spectra Ratio (HVSR) were used to distinguish respective frequencies of building and ground natural frequencies. Three dominant frequencies were identified from the FAS curves at 1.91 Hz, 1.98 Hz and 2.79 Hz in longitudinal (East West-EW), transverse (North South-NS) and vertical (UD) directions. It is expected the building has deformed in translational mode based on the first peak frequency by respective NS and EW components of FAS spectrum. Vertical frequency identified from the horizontal spectrums, might induces to the potential of rocking effect experienced by the school building. Meanwhile, single peak HVSR spectrum at low ground fundamental frequency concentrated at 0.93 Hz indicates to the existence deep contrast of soft deposit. Strong interaction between ground and building at similar frequency (0.93 Hz) observed from the FAS curves on the highest floor has shown the building to behave as a dependent unit against ground response as one rigid mass.

  3. A Novel Multimode Waveguide Coupler for Accurate Power Measurement of Traveling Wave Tube Harmonic Frequencies

    NASA Technical Reports Server (NTRS)

    Wintucky, Edwin G.; Simons, Rainee N.

    2014-01-01

    This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from two dissimilar waveguides is capable of isolating the power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT). In addition to accurate power measurements at harmonic frequencies, a potential application of the MDC is in the design of a beacon source for atmospheric propagation studies at millimeter-wave frequencies.

  4. The influence of low frequency sound on the changes of EEG signal morphology

    NASA Astrophysics Data System (ADS)

    Damijan, Z.; Wiciak, J.

    2006-11-01

    The effects of low frequency sound on the changes of morphology of the spectral power density function of EEG signals were studied as a part of the research program f = 40 Hz, Lp = 110 dB HP. The research program involved 33 experiments. A quantitative analysis was conducted of the driving response effect for the fundamental frequency and its harmonics to find the frequency of the driving response effect occurrence depending on the sex of participants.

  5. Thermal Noise Limit in Frequency Stabilization of Lasers with Rigid Cavities

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Kemery, Amy; Camp, Jordan

    2005-01-01

    We evaluated thermal noise (Brownian motion) in a rigid reference cavity Used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with the direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency-reference cavity of order 1 Hz/rtHz at 10mHz at room temperature. This level coincides with the world-highest level stabilization results.

  6. Tape recorder effects on jitter and shimmer extraction.

    PubMed

    Doherty, E T; Shipp, T

    1988-09-01

    To test for possible contamination of acoustic analyses by record/reproduce systems, five sine waves of fixed frequency and amplitude were sampled directly by a computer and recorded simultaneously on four different tape formats (audio and FM reel-to-reel, audio cassette, and video cassette using pulse code modulation). Recordings were digitized on playback and with the direct samples analyzed for fundamental frequency, amplitude, jitter, and shimmer using a zero crossing interpolation scheme. Distortion introduced by any of the data acquisition systems is negligible when extracting average fundamental frequency or average amplitude. For jitter and shimmer estimation, direct sampling or the use of a video cassette recorder with pulse code modulation are clearly superior. FM recorders, although not quite as accurate, provide a satisfactory alternative to those methods. Audio reel-to-reel recordings are marginally adequate for jitter analysis whereas audio cassette recorders can introduce jitter and shimmer values that are greater than some reported values for normal talkers.

  7. The Developmental Dynamics of Terrorist Organizations

    PubMed Central

    Clauset, Aaron; Gleditsch, Kristian Skrede

    2012-01-01

    We identify robust statistical patterns in the frequency and severity of violent attacks by terrorist organizations as they grow and age. Using group-level static and dynamic analyses of terrorist events worldwide from 1968–2008 and a simulation model of organizational dynamics, we show that the production of violent events tends to accelerate with increasing size and experience. This coupling of frequency, experience and size arises from a fundamental positive feedback loop in which attacks lead to growth which leads to increased production of new attacks. In contrast, event severity is independent of both size and experience. Thus larger, more experienced organizations are more deadly because they attack more frequently, not because their attacks are more deadly, and large events are equally likely to come from large and small organizations. These results hold across political ideologies and time, suggesting that the frequency and severity of terrorism may be constrained by fundamental processes. PMID:23185267

  8. Average speaking fundamental frequency in soprano singers with and without symptoms of vocal attrition.

    PubMed

    Drew, R; Sapir, S

    1995-06-01

    Nineteen trained soprano singers aged 18-30 years vocalized tasks designed to assess average speaking fundamental frequency (SFF) during spontaneous speaking and reading. Vocal range and perceptual characteristics while singing with low intensity and high frequency were also assessed, and subjects completed a survey of vocal habits/symptoms. Recorded signals were digitized prior to being analyzed for SFF using the Kay Computerized Speech Lab program. Subjects were assigned to a normal voice or impaired voice group based on ratings of perceptual tasks and survey results. Data analysis showed group differences in mean SFF, no differences in vocal range, higher mean SFF values for reading than speaking, and 58% ability to perceive speaking in low pitch. The role of speaking in too low pitch as causal for vocal symptoms and need for voice classification differentiation in vocal performance studies are discussed.

  9. Acoustic measurement of the surface tension of levitated drops

    NASA Technical Reports Server (NTRS)

    Trinh, E. H.; Marston, P. L.; Robey, J. L.

    1988-01-01

    The measurement of the frequency of the fundamental mode of shape oscillation of acoustically levitated drops has been carried out to determine the surface tension of the drop material. Sound fields of about 20 kHz in frequency allow the suspension of drops a few millimeters in size, as well as the necessary drive for oscillations. The surface tension of water, hexadecane, silicone oil, and aqueous solutions of glycerin levitated in air has been measured, and the results have been compared with those obtained with standard ring tensiometry. The two sets of data are in good agreement, the largest discrepancy being about 10 percent. Uncertainties in the effects of the nonspherical static shape of drops levitated in the earth's gravitational field and the rotation state of the sample are the major contributors to the experimental error. A decrease of the resonance frequency of the fundamental mode indicates a soft nonlinearity as the oscillation amplitude increases.

  10. Determination of the electromechanical coupling factor of gallium orthophosphate (GaPO4) and its influence on resonance-frequency temperature dependencies.

    PubMed

    Nosek, Jaroslav; Pustka, Martin

    2006-01-01

    The quartz homeotype gallium orthophosphate (GaPO4) is a representative of piezoelectric single crystals of large electromechanical coupling factor. It is known that its coupling factor kappa26 associated with the resonators vibrating in the thickness-shear mode is approximately two times greater than that of quartz. This property increases the spacing between the series and parallel resonance frequencies of resonators, as well as the difference between the resonance frequency temperature dependencies of the fundamental and harmonic resonance frequencies of resonators vibrating in the thickness-shear mode. In this paper, the methods for determination of the coupling factor kappa26 are presented, and the computed values are compared with the measured ones. The influence of the coupling factor to the resonance-frequency temperature dependencies of the fundamental and third harmonics of selected rotated Y-cut GaPO4 resonators vibrating in the thickness-shear mode is presented. The purely elastic case for a laterally unbounded plate, which corresponds closely to the limiting case of high harmonic resonance frequency-temperature behavior was assumed for the calculations. The computed temperature coefficients for the Y-cut orientation and calculated turnover point temperatures TTP for different (YX1) orientations are presented.

  11. A comparison of spectral magnitude and phase-locking value analyses of the frequency-following response to complex tones

    PubMed Central

    Zhu, Li; Bharadwaj, Hari; Xia, Jing; Shinn-Cunningham, Barbara

    2013-01-01

    Two experiments, both presenting diotic, harmonic tone complexes (100 Hz fundamental), were conducted to explore the envelope-related component of the frequency-following response (FFRENV), a measure of synchronous, subcortical neural activity evoked by a periodic acoustic input. Experiment 1 directly compared two common analysis methods, computing the magnitude spectrum and the phase-locking value (PLV). Bootstrapping identified which FFRENV frequency components were statistically above the noise floor for each metric and quantified the statistical power of the approaches. Across listeners and conditions, the two methods produced highly correlated results. However, PLV analysis required fewer processing stages to produce readily interpretable results. Moreover, at the fundamental frequency of the input, PLVs were farther above the metric's noise floor than spectral magnitudes. Having established the advantages of PLV analysis, the efficacy of the approach was further demonstrated by investigating how different acoustic frequencies contribute to FFRENV, analyzing responses to complex tones composed of different acoustic harmonics of 100 Hz (Experiment 2). Results show that the FFRENV response is dominated by peripheral auditory channels responding to unresolved harmonics, although low-frequency channels driven by resolved harmonics also contribute. These results demonstrate the utility of the PLV for quantifying the strength of FFRENV across conditions. PMID:23862815

  12. Beamed microwave power transmitting and receiving subsystems radiation characteristics

    NASA Technical Reports Server (NTRS)

    Dickinson, R. M.

    1980-01-01

    Measured characteristics of the spectrum of typical converters and the distribution of radiated Radio Frequency (RF) energy from the terminals (transmitting antenna and rectenna) of a beamed microwave power subsystem are presented for small transmitting and receiving S-band (2.45 GHz) subarrays. Noise and harmonic levels of tube and solid-state RF power amplifiers are shown. The RF patterns and envelope of a 64 element slotted waveguide antenna are given for the fundamental frequency and harmonics through the fifth. Reflected fundamental and harmonic patterns through the fourth for a 42 element rectenna subarray are presented for various dc load and illumination conditions. Bandwidth measurements for the waveguide antenna and rectenna are shown.

  13. Extraction of small boat harmonic signatures from passive sonar.

    PubMed

    Ogden, George L; Zurk, Lisa M; Jones, Mark E; Peterson, Mary E

    2011-06-01

    This paper investigates the extraction of acoustic signatures from small boats using a passive sonar system. Noise radiated from a small boats consists of broadband noise and harmonically related tones that correspond to engine and propeller specifications. A signal processing method to automatically extract the harmonic structure of noise radiated from small boats is developed. The Harmonic Extraction and Analysis Tool (HEAT) estimates the instantaneous fundamental frequency of the harmonic tones, refines the fundamental frequency estimate using a Kalman filter, and automatically extracts the amplitudes of the harmonic tonals to generate a harmonic signature for the boat. Results are presented that show the HEAT algorithms ability to extract these signatures. © 2011 Acoustical Society of America

  14. Stochastic resonance in micro/nano cantilever sensors

    NASA Astrophysics Data System (ADS)

    Singh, Priyanka; Yadava, R. D. S.

    2018-05-01

    In this paper we present a comparative study on the stochastic resonance in micro/nano cantilever resonators due to fluctuations in the fundamental frequency or the damping coefficient. Considering DC+AC electrostatic actuation in the presence of zero-mean Gaussian noise with exponential autocorrelation we analyze stochastic resonance behaviors for the frequency and the damping fluctuations separately, and compare the effects of stochastic resonance on Q-factor of the resonators for different levels of damping losses. It is found that even though the stochastic resonance occurs for both types of fluctuations, only the damping fluctuation produces right cooperative influence on the fundamental resonance that improves both the amplitude response and the quality factor of the resonator.

  15. Highly Accurate Quartic Force Fields, Vibrational Frequencies, and Spectroscopic Constants for Cyclic and Linear C3H3(+)

    NASA Technical Reports Server (NTRS)

    Huang, Xinchuan; Taylor, Peter R.; Lee, Timothy J.

    2011-01-01

    High levels of theory have been used to compute quartic force fields (QFFs) for the cyclic and linear forms of the C H + molecular cation, referred to as c-C H + and I-C H +. Specifically the 33 3333 singles and doubles coupled-cluster method that includes a perturbational estimate of connected triple excitations, CCSD(T), has been used in conjunction with extrapolation to the one-particle basis set limit and corrections for scalar relativity and core correlation have been included. The QFFs have been used to compute highly accurate fundamental vibrational frequencies and other spectroscopic constants using both vibrational 2nd-order perturbation theory and variational methods to solve the nuclear Schroedinger equation. Agreement between our best computed fundamental vibrational frequencies and recent infrared photodissociation experiments is reasonable for most bands, but there are a few exceptions. Possible sources for the discrepancies are discussed. We determine the energy difference between the cyclic and linear forms of C H +, 33 obtaining 27.9 kcal/mol at 0 K, which should be the most reliable available. It is expected that the fundamental vibrational frequencies and spectroscopic constants presented here for c-C H + 33 and I-C H + are the most reliable available for the free gas-phase species and it is hoped that 33 these will be useful in the assignment of future high-resolution laboratory experiments or astronomical observations.

  16. Frequency tripling of convergent beam employing crystals tiling in large-aperture high-energy laser facilities

    NASA Astrophysics Data System (ADS)

    Wang, Junhua; Li, Dazhen; Wang, Bo; Yang, Jing; Yang, Houwen; Wang, Xiaoqian; Cheng, Wenyong

    2017-11-01

    In inertial confinement fusion, ultraviolet laser damage of the fused silica lens is an important limiting factor for load capability of the laser driver. To solve this problem, a new configuration of frequency tripling is proposed in this paper. The frequency tripling crystal is placed on downstream of the focusing lens, thus sum frequency generation of fundamental frequency light and doubling frequency light occurs in the beam convergence path. The focusing lens is only irradiated by fundamental light and doubling frequency lights. Thus, its damage threshold will increase. LiB3O5 (LBO) crystals are employed as frequency tripling crystals for its larger acceptance angle and higher damage threshold than KDP/DKDP crystals'. With the limitation of acceptance angle and crystal growth size are taken into account, the tiling scheme of LBO crystals is proposed and designed optimally to adopt to the total convergence angle of 36.0 mrad. Theoretical results indicate that 3 LBO crystals titling with different cutting angles in θ direction can meet the phase matching condition. Compared with frequency tripling of parallel beam using one LBO crystal, 83.8% (93.1% with 5 LBO crystals tiling) of the frequency tripling conversion efficiency can be obtained employing this new configuration. The results of a principle experiment also support this scheme. By employing this new design, not only the load capacity of a laser driver will be significantly improved, but also the fused silica lens can be changed to K9 glass lens which has the mature technology and low cost.

  17. Fundamental and subharmonic excitation for an oscillator with several tunneling diodes in series

    NASA Technical Reports Server (NTRS)

    Boric-Lubecke, Olga; Pan, Dee-Son; Itoh, Tatsuo

    1995-01-01

    Connecting several tunneling diodes in series shows promise as a method for increasing the output power of these devices as millimeter-wave oscillators. However, due to the negative differential resistance (NDR) region in the dc I-V curve of a single tunneling diode, a circuit using several devices connected in series, and biased simultaneously in the NDR region, is dc unstable. Because of this instability, an oscillator with several tunneling diodes in series has a demanding excitation condition. Excitation using an externally applied RF signal is one approach to solving this problem. This is experimentally demonstrated using an RF source, both with frequency close to as well as with frequency considerably lower than the oscillation frequency. Excitation by an RF (radio frequency) source with a frequency as low as one sixth of the oscillation frequency was demonstrated in a proof-of-principle experiment at 2 GHz, for an oscillator with two tunnel diodes connected in series. Strong harmonics of the oscillation signal were generated as a result of the highly nonlinear dc I-V curve of the tunnel diode and a large signal oscillator design. Third harmonic output power comparable to that of the fundamental was observed in one oscillator circuit. If submillimeter wave resonant-tunneling diodes (RTD's) are used instead of tunnel diodes, this harmonic output may be useful for generating signals at frequencies well into the terahertz range.

  18. Digital hum filtering

    USGS Publications Warehouse

    Knapp, R.W.; Anderson, N.L.

    1994-01-01

    Data may be overprinted by a steady-state cyclical noise (hum). Steady-state indicates that the noise is invariant with time; its attributes, frequency, amplitude, and phase, do not change with time. Hum recorded on seismic data usually is powerline noise and associated higher harmonics; leakage from full-waveform rectified cathodic protection devices that contain the odd higher harmonics of powerline frequencies; or vibrational noise from mechanical devices. The fundamental frequency of powerline hum may be removed during data acquisition with the use of notch filters. Unfortunately, notch filters do not discriminate signal and noise, attenuating both. They also distort adjacent frequencies by phase shifting. Finally, they attenuate only the fundamental mode of the powerline noise; higher harmonics and frequencies other than that of powerlines are not removed. Digital notch filters, applied during processing, have many of the same problems as analog filters applied in the field. The method described here removes hum of a particular frequency. Hum attributes are measured by discrete Fourier analysis, and the hum is canceled from the data by subtraction. Errors are slight and the result of the presence of (random) noise in the window or asynchrony of the hum and data sampling. Error is minimized by increasing window size or by resampling to a finer interval. Errors affect the degree of hum attenuation, not the signal. The residual is steady-state hum of the same frequency. ?? 1994.

  19. Robust k-mer frequency estimation using gapped k-mers

    PubMed Central

    Ghandi, Mahmoud; Mohammad-Noori, Morteza

    2013-01-01

    Oligomers of fixed length, k, commonly known as k-mers, are often used as fundamental elements in the description of DNA sequence features of diverse biological function, or as intermediate elements in the constuction of more complex descriptors of sequence features such as position weight matrices. k-mers are very useful as general sequence features because they constitute a complete and unbiased feature set, and do not require parameterization based on incomplete knowledge of biological mechanisms. However, a fundamental limitation in the use of k-mers as sequence features is that as k is increased, larger spatial correlations in DNA sequence elements can be described, but the frequency of observing any specific k-mer becomes very small, and rapidly approaches a sparse matrix of binary counts. Thus any statistical learning approach using k-mers will be susceptible to noisy estimation of k-mer frequencies once k becomes large. Because all molecular DNA interactions have limited spatial extent, gapped k-mers often carry the relevant biological signal. Here we use gapped k-mer counts to more robustly estimate the ungapped k-mer frequencies, by deriving an equation for the minimum norm estimate of k-mer frequencies given an observed set of gapped k-mer frequencies. We demonstrate that this approach provides a more accurate estimate of the k-mer frequencies in real biological sequences using a sample of CTCF binding sites in the human genome. PMID:23861010

  20. Robust k-mer frequency estimation using gapped k-mers.

    PubMed

    Ghandi, Mahmoud; Mohammad-Noori, Morteza; Beer, Michael A

    2014-08-01

    Oligomers of fixed length, k, commonly known as k-mers, are often used as fundamental elements in the description of DNA sequence features of diverse biological function, or as intermediate elements in the constuction of more complex descriptors of sequence features such as position weight matrices. k-mers are very useful as general sequence features because they constitute a complete and unbiased feature set, and do not require parameterization based on incomplete knowledge of biological mechanisms. However, a fundamental limitation in the use of k-mers as sequence features is that as k is increased, larger spatial correlations in DNA sequence elements can be described, but the frequency of observing any specific k-mer becomes very small, and rapidly approaches a sparse matrix of binary counts. Thus any statistical learning approach using k-mers will be susceptible to noisy estimation of k-mer frequencies once k becomes large. Because all molecular DNA interactions have limited spatial extent, gapped k-mers often carry the relevant biological signal. Here we use gapped k-mer counts to more robustly estimate the ungapped k-mer frequencies, by deriving an equation for the minimum norm estimate of k-mer frequencies given an observed set of gapped k-mer frequencies. We demonstrate that this approach provides a more accurate estimate of the k-mer frequencies in real biological sequences using a sample of CTCF binding sites in the human genome.

  1. A fundamental residue pitch perception bias for tone language speakers

    NASA Astrophysics Data System (ADS)

    Petitti, Elizabeth

    A complex tone composed of only higher-order harmonics typically elicits a pitch percept equivalent to the tone's missing fundamental frequency (f0). When judging the direction of residue pitch change between two such tones, however, listeners may have completely opposite perceptual experiences depending on whether they are biased to perceive changes based on the overall spectrum or the missing f0 (harmonic spacing). Individual differences in residue pitch change judgments are reliable and have been associated with musical experience and functional neuroanatomy. Tone languages put greater pitch processing demands on their speakers than non-tone languages, and we investigated whether these lifelong differences in linguistic pitch processing affect listeners' bias for residue pitch. We asked native tone language speakers and native English speakers to perform a pitch judgment task for two tones with missing fundamental frequencies. Given tone pairs with ambiguous pitch changes, listeners were asked to judge the direction of pitch change, where the direction of their response indicated whether they attended to the overall spectrum (exhibiting a spectral bias) or the missing f0 (exhibiting a fundamental bias). We found that tone language speakers are significantly more likely to perceive pitch changes based on the missing f0 than English speakers. These results suggest that tone-language speakers' privileged experience with linguistic pitch fundamentally tunes their basic auditory processing.

  2. Amplitude and frequency modulation control of sound production in a mechanical model of the avian syrinx.

    PubMed

    Elemans, Coen P H; Muller, Mees; Larsen, Ole Naesbye; van Leeuwen, Johan L

    2009-04-01

    Birdsong has developed into one of the important models for motor control of learned behaviour and shows many parallels with speech acquisition in humans. However, there are several experimental limitations to studying the vocal organ - the syrinx - in vivo. The multidisciplinary approach of combining experimental data and mathematical modelling has greatly improved the understanding of neural control and peripheral motor dynamics of sound generation in birds. Here, we present a simple mechanical model of the syrinx that facilitates detailed study of vibrations and sound production. Our model resembles the 'starling resistor', a collapsible tube model, and consists of a tube with a single membrane in its casing, suspended in an external pressure chamber and driven by various pressure patterns. With this design, we can separately control 'bronchial' pressure and tension in the oscillating membrane and generate a wide variety of 'syllables' with simple sweeps of the control parameters. We show that the membrane exhibits high frequency, self-sustained oscillations in the audio range (>600 Hz fundamental frequency) using laser Doppler vibrometry, and systematically explore the conditions for sound production of the model in its control space. The fundamental frequency of the sound increases with tension in three membranes with different stiffness and mass. The lower-bound fundamental frequency increases with membrane mass. The membrane vibrations are strongly coupled to the resonance properties of the distal tube, most likely because of its reflective properties to sound waves. Our model is a gross simplification of the complex morphology found in birds, and more closely resembles mathematical models of the syrinx. Our results confirm several assumptions underlying existing mathematical models in a complex geometry.

  3. Multimode Directional Coupler for Utilization of Harmonic Frequencies from TWTAs

    NASA Technical Reports Server (NTRS)

    Simmons, Rainee N.; Wintucky, Edwin G.

    2013-01-01

    A novel waveguide multimode directional coupler (MDC) intended for the measurement and potential utilization of the second and higher order harmonic frequencies from high-power traveling wave tube amplifiers (TWTAs) has been successfully designed, fabricated, and tested. The design is based on the characteristic multiple propagation modes of the electrical and magnetic field components of electromagnetic waves in a rectangular waveguide. The purpose was to create a rugged, easily constructed, more efficient waveguide- based MDC for extraction and exploitation of the second harmonic signal from the RF output of high-power TWTs used for space communications. The application would be a satellitebased beacon source needed for Qband and V/W-band atmospheric propagation studies. The MDC could function as a CW narrow-band source or as a wideband source for study of atmospheric group delay effects on highdata- rate links. The MDC is fabricated from two sections of waveguide - a primary one for the fundamental frequency and a secondary waveguide for the second harmonic - that are joined together such that the second harmonic higher order modes are selectively coupled via precision- machined slots for propagation in the secondary waveguide. In the TWTA output waveguide port, both the fundamental and the second harmonic signals are present. These signals propagate in the output waveguide as the dominant and higher order modes, respectively. By including an appropriate mode selective waveguide directional coupler, such as the MDC presented here at the output of the TWTA, the power at the second harmonic can be sampled and amplified to the power level needed for atmospheric propagation studies. The important conclusions from the preliminary test results for the multimode directional coupler are: (1) the second harmonic (Ka-band) can be measured and effectively separated from the fundamental (Ku-band) with no coupling of the latter, (2) power losses in the fundamental frequency are negligible, and (3) the power level of the extracted second harmonic is sufficient for further amplification to power levels needed for practical applications. It was also demonstrated that third order and potentially higher order harmonics are measurable with this device. The design is frequency agnostic, and with the appropriate choice of waveguides, is easily scaled to higher frequency TWTs. The MDC has the same function but with a number of important advantages over the conventional diplexer.

  4. Frequency-velocity mismatch: a fundamental abnormality in parkinsonian gait.

    PubMed

    Cho, Catherine; Kunin, Mikhail; Kudo, Koji; Osaki, Yasuhiro; Olanow, C Warren; Cohen, Bernard; Raphan, Theodore

    2010-03-01

    Gait dysfunction and falling are major sources of disability for patients with advanced Parkinson's disease (PD). It is presently thought that the fundamental defect is an inability to generate normal stride length. Our data suggest, however, that the basic problem in PD gait is an impaired ability to match step frequency to walking velocity. In this study, foot movements of PD and normal subjects were monitored with an OPTOTRAK motion-detection system while they walked on a treadmill at different velocities. PD subjects were also paced with auditory stimuli at different frequencies. PD gait was characterized by step frequencies that were faster and stride lengths that were shorter than those of normal controls. At low walking velocities, PD stepping had a reduced or absent terminal toe lift, which truncated swing phases, producing shortened steps. Auditory pacing was not able to normalize step frequency at these lower velocities. Peak forward toe velocities increased with walking velocity and PD subjects could initiate appropriate foot dynamics during initial phases of the swing. They could not control the foot appropriately in terminal phases, however. Increased treadmill velocity, which matched the natural PD step frequency, generated a second toe lift, normalizing step size. Levodopa increased the bandwidth of step frequencies, but was not as effective as increases in walking velocity in normalizing gait. We postulate that the inability to control step frequency and adjust swing phase dynamics to slower walking velocities are major causes for the gait impairment in PD.

  5. Frequency-Velocity Mismatch: A Fundamental Abnormality in Parkinsonian Gait

    PubMed Central

    Kunin, Mikhail; Kudo, Koji; Osaki, Yasuhiro; Olanow, C. Warren; Cohen, Bernard; Raphan, Theodore

    2010-01-01

    Gait dysfunction and falling are major sources of disability for patients with advanced Parkinson's disease (PD). It is presently thought that the fundamental defect is an inability to generate normal stride length. Our data suggest, however, that the basic problem in PD gait is an impaired ability to match step frequency to walking velocity. In this study, foot movements of PD and normal subjects were monitored with an OPTOTRAK motion-detection system while they walked on a treadmill at different velocities. PD subjects were also paced with auditory stimuli at different frequencies. PD gait was characterized by step frequencies that were faster and stride lengths that were shorter than those of normal controls. At low walking velocities, PD stepping had a reduced or absent terminal toe lift, which truncated swing phases, producing shortened steps. Auditory pacing was not able to normalize step frequency at these lower velocities. Peak forward toe velocities increased with walking velocity and PD subjects could initiate appropriate foot dynamics during initial phases of the swing. They could not control the foot appropriately in terminal phases, however. Increased treadmill velocity, which matched the natural PD step frequency, generated a second toe lift, normalizing step size. Levodopa increased the bandwidth of step frequencies, but was not as effective as increases in walking velocity in normalizing gait. We postulate that the inability to control step frequency and adjust swing phase dynamics to slower walking velocities are major causes for the gait impairment in PD. PMID:20042701

  6. Near-Field Sound Localization Based on the Small Profile Monaural Structure

    PubMed Central

    Kim, Youngwoong; Kim, Keonwook

    2015-01-01

    The acoustic wave around a sound source in the near-field area presents unconventional properties in the temporal, spectral, and spatial domains due to the propagation mechanism. This paper investigates a near-field sound localizer in a small profile structure with a single microphone. The asymmetric structure around the microphone provides a distinctive spectral variation that can be recognized by the dedicated algorithm for directional localization. The physical structure consists of ten pipes of different lengths in a vertical fashion and rectangular wings positioned between the pipes in radial directions. The sound from an individual direction travels through the nearest open pipe, which generates the particular fundamental frequency according to the acoustic resonance. The Cepstral parameter is modified to evaluate the fundamental frequency. Once the system estimates the fundamental frequency of the received signal, the length of arrival and angle of arrival (AoA) are derived by the designed model. From an azimuthal distance of 3–15 cm from the outer body of the pipes, the extensive acoustic experiments with a 3D-printed structure show that the direct and side directions deliver average hit rates of 89% and 73%, respectively. The closer positions to the system demonstrate higher accuracy, and the overall hit rate performance is 78% up to 15 cm away from the structure body. PMID:26580618

  7. Effects of Parkinson's Disease on Fundamental Frequency Variability in Running Speech.

    PubMed

    Bowen, Leah K; Hands, Gabrielle L; Pradhan, Sujata; Stepp, Cara E

    2013-09-01

    In Parkinson's Disease (PD), qualitative speech changes such as decreased variation in pitch and loudness are common, but quantitative vocal changes are not well documented. The variability of fundamental frequency (F0) in 32 individuals (23 male) with PD both ON and OFF levodopa medication was compared with 32 age-matched healthy controls (23 male). Participants read a single paragraph and estimates of fundamental frequency (F0) variability were determined for the entire reading passage as well as for the first and last sentences of the passage separately. F0 variability was significantly increased in controls relative to both PD groups and PD patients showed significantly higher F0 variability while ON medication relative to OFF. No significant effect of group was seen in the change in F0 variability from the beginning to the end of the reading passage. Female speakers were found to have higher F0 variability than males. F0 variability was both significantly reduced in PD relative to controls and significantly increased in patients with PD during use of dopaminergic medications. F0 variability changes over the course of reading a paragraph may not be indicative of PD but rather dependent on non-disease factors such as the linguistic characteristics of the text.

  8. Influence and interactions of laryngeal adductors and cricothyroid muscles on fundamental frequency and glottal posture control

    PubMed Central

    Chhetri, Dinesh K.; Neubauer, Juergen; Sofer, Elazar; Berry, David A.

    2014-01-01

    The interactions of the intrinsic laryngeal muscles (ILMs) in controlling fundamental frequency (F0) and glottal posture remain unclear. In an in vivo canine model, three sets of intrinsic laryngeal muscles—the thyroarytenoid (TA), cricothyroid (CT), and lateral cricoarytenoid plus interarytenoid (LCA/IA) muscle complex—were independently and accurately stimulated in a graded manner using distal laryngeal nerve stimulation. Graded neuromuscular stimulation was used to independently activate these paired intrinsic laryngeal muscles over a range from threshold to maximal activation, to produce 320 distinct laryngeal phonatory postures. At phonation onset these activation conditions were evaluated in terms of their vocal fold strain, glottal width at the vocal processes, fundamental frequency (F0), subglottic pressure, and airflow. F0 ranged from 69 to 772 Hz and clustered into chest-like and falsetto-like groups. CT activation was always required to raise F0, but could also lower F0 at low TA and LCA/IA activation levels. Increasing TA activation first increased then decreased F0 in all CT and LCA/IA activation conditions. Increasing TA activation also facilitated production of high F0 at a lower onset pressure. Independent control of membranous (TA) and cartilaginous (LCA/IA) glottal closure enabled multiple pathways for F0 control via changes in glottal posture. PMID:25235003

  9. Clock distribution system for digital computers

    DOEpatents

    Wyman, Robert H.; Loomis, Jr., Herschel H.

    1981-01-01

    Apparatus for eliminating, in each clock distribution amplifier of a clock distribution system, sequential pulse catch-up error due to one pulse "overtaking" a prior clock pulse. The apparatus includes timing means to produce a periodic electromagnetic signal with a fundamental frequency having a fundamental frequency component V'.sub.01 (t); an array of N signal characteristic detector means, with detector means No. 1 receiving the timing means signal and producing a change-of-state signal V.sub.1 (t) in response to receipt of a signal above a predetermined threshold; N substantially identical filter means, one filter means being operatively associated with each detector means, for receiving the change-of-state signal V.sub.n (t) and producing a modified change-of-state signal V'.sub.n (t) (n=1, . . . , N) having a fundamental frequency component that is substantially proportional to V'.sub.01 (t-.theta..sub.n (t) with a cumulative phase shift .theta..sub.n (t) having a time derivative that may be made uniformly and arbitrarily small; and with the detector means n+1 (1.ltoreq.n

  10. Some Applications of Fourier's Great Discovery for Beginners

    ERIC Educational Resources Information Center

    Kraftmakher, Yaakov

    2012-01-01

    Nearly two centuries ago, Fourier discovered that any periodic function of period T can be presented as a sum of sine waveforms of frequencies equal to an integer times the fundamental frequency [omega] = 2[pi]/T (Fourier's series). It is impossible to overestimate the importance of Fourier's discovery, and all physics or engineering students…

  11. Auditory Attention to Frequency and Time: An Analogy to Visual Local-Global Stimuli

    ERIC Educational Resources Information Center

    Justus, Timothy; List, Alexandra

    2005-01-01

    Two priming experiments demonstrated exogenous attentional persistence to the fundamental auditory dimensions of frequency (Experiment 1) and time (Experiment 2). In a divided-attention task, participants responded to an independent dimension, the identification of three-tone sequence patterns, for both prime and probe stimuli. The stimuli were…

  12. Perceptual Grouping Affects Pitch Judgments across Time and Frequency

    ERIC Educational Resources Information Center

    Borchert, Elizabeth M. O.; Micheyl, Christophe; Oxenham, Andrew J.

    2011-01-01

    Pitch, the perceptual correlate of fundamental frequency (F0), plays an important role in speech, music, and animal vocalizations. Changes in F0 over time help define musical melodies and speech prosody, while comparisons of simultaneous F0 are important for musical harmony, and for segregating competing sound sources. This study compared…

  13. Theoretical Analysis About Quantum Noise Squeezing of Optical Fields From an Intracavity Frequency-Doubled Laser

    NASA Technical Reports Server (NTRS)

    Zhang, Kuanshou; Xie, Changde; Peng, Kunchi

    1996-01-01

    The dependence of the quantum fluctuation of the output fundamental and second-harmonic waves upon cavity configuration has been numerically calculated for the intracavity frequency-doubled laser. The results might provide a direct reference for the design of squeezing system through the second-harmonic-generation.

  14. Variability in Phonetics. York Papers in Linguistics, No. 6.

    ERIC Educational Resources Information Center

    Tatham, M. A. A.

    Variability is a term used to cover several types of phenomena in language sound patterns and in phonetic realization of those patterns. Variability refers to the fact that every repetition of an utterance is different, in amplitude, rate of delivery, formant frequencies, fundamental frequency or minor phase relationship changes across the sound…

  15. Subharmonic and fundamental high amplitude excitation of an axisymmetric jet

    NASA Technical Reports Server (NTRS)

    Raman, Ganesh; Rice, Edward J.

    1989-01-01

    A circular jet was excited simultaneously by two different harmonically related tones. Data for three pairs of Strouhal numbers (St(D) = f*D/U (sub j) = 0.2 and 0.4, 0.3 and 0.6, 0.4 and 0.8). For each case the initial phase difference between the two waves was varied in steps of 45 deg, for one full cycle and the level of the fundamental and subharmonic forcing were varied independently over the range of 0.1 to 7 percent of the jet exit velocity. Our initial findings concurred with published findings, such as a critical level of the fundamental is required for subharmonic augmentation, the initial phase difference is critical in determining whether the subharmonic is augmented or suppressed. The detailed documentation of several aspects of this phenomenon all measured in one and the same experimental facility in a controlled manner, bring out several important points that eluded previous researchers: (1) At high amplitudes of the fundamental and subharmonic forcing levels the subharmonic augmentation is independent of the initial phase difference. (2) Contrary to the earlier belief that stable pairing could be produced only with an initial laminar boundary layer, the present work shows that by the two-frequency excitation method this phenomenon can be induced over a range of conditions for a jet with an initially turbulent boundary layer. (3) It is seen that two-frequency excitation is indeed more effective than single frequency excitation in jet mixing enhancement. Higher spreading rates seem to go along with higher subharmonic levels.

  16. Resonant Triad in Boundary-Layer Stability. Part 2; Composite Solution and Comparison with Observations

    NASA Technical Reports Server (NTRS)

    Mankbadi, Reda R.

    1991-01-01

    Here, numerical results are computed from an asymptotic near-resonance triad analysis. The analysis considers a resonant triad of instability waves consisting of a plane fundamental wave and a pair of symmetrical oblique subharmonic waves. The relevant scaling ensures that nonlinearity is confined to a distinct critical layer. The analysis is first used to form a composite solution that accounts for both the flow divergence and nonlinear effects. It is shown that the backreaction on the plane Tollmien Schlichting (TS) fundamental wave, although fully accounted for, is of little significance. The observed enhancement at the fundamental frequency disturbance is not in the plane TS wave, but is caused by nonlinearly generated waves at the fundamental frequency that result from nonlinear interactions in the critical layer. The saturation of the oblique waves is caused by their self-interaction. The nonlinear phase-locking phenomenon, the location of resonance with respect to the neutral stability curve, low frequency effects, detuning in the streamwise wave numbers, and nonlinear distortion of the mode shapes are discussed. Nonlinearity modifies the initially two dimensional Blasius profile into a fuller one with spanwise periodicity. The interactions at a wide range of unstable spanwise wave numbers are considered, and the existence of a preferred spanwise wave number is explained by means of the vorticity distribution in the critical layer. Besides presenting novel features of the phenomena and explaining the delicate mechanisms of the interactions, the results of the theory are in excellent agreement with experimental and numerical observations for all stages of the development and for various input parameters.

  17. Annoyance caused by advanced turboprop aircraft flyover noise: Single-rotating propeller configuration

    NASA Technical Reports Server (NTRS)

    Mccurdy, David A.

    1988-01-01

    Two experiments were conducted to quantify the annoyance of people to advanced turboprop (propfan) aircraft flyover noise. The objectives were to: (1) determine the effects on annoyance of various tonal characteristics; and (2) compare annoyance to advanced turboprops with annoyance to conventional turboprops and jets. A computer was used to produce realistic, time-varying simulations of advanced turboprop aircraft takeoff noise. In the first experiment, subjects judged the annoyance of 45 advanced turboprop noises in which the tonal content was systematically varied to represent the factorial combinations of five fundamental frequencies, three frequency envelope shapes, and three tone-to-broadband noise ratios. Each noise was presented at three sound levels. In the second experiment, 18 advanced turboprop takeoffs, 5 conventional turboprop takeoffs, and 5 conventional jet takeoffs were presented at three sound pressure levels to subjects. Analysis indicated that frequency envelope shape did not significantly affect annoyance. The interaction of fundamental frequency with tone-to-broadband noise ratio did have a large and complex effect on annoyance. The advanced turboprop stimuli were slightly less annoying than the conventional stimuli.

  18. ``Stable'' Quasi-periodic Oscillations and Black Hole Properties from Diskoseismology

    NASA Astrophysics Data System (ADS)

    Wagoner, Robert V.; Silbergleit, Alexander S.; Ortega-Rodríguez, Manuel

    2001-09-01

    We compare our calculations of the frequencies of the fundamental g-, c-, and p-modes of relativistic thin accretion disks with recent observations of high-frequency quasi-periodic oscillations (QPOs) in X-ray binaries with black hole candidates. These classes of modes encompass all adiabatic perturbations of such disks. The frequencies of these modes depend mainly on the mass and angular momentum of the black hole; their weak dependence on disk luminosity is also explicitly indicated. Identifying the recently discovered, relatively stable QPO pairs with the fundamental g- and c-modes provides a determination of the mass and angular momentum of the black hole. For GRO J1655-40, M=5.9+/-1.0 Msolar and J=(0.917+/-0.024)GM2/c, in agreement with spectroscopic mass determinations. For GRS 1915+105, M=42.4+/-7.0 Msolar and J=(0.926+/-0.020)GM2/c or (less favored) M=18.2+/-3.1 Msolar and J=(0.701+/-0.043)GM2/c. We briefly address the issues of the amplitude, frequency width, and energy dependence of these QPOs.

  19. Audio-vocal responses of vocal fundamental frequency and formant during sustained vowel vocalizations in different noises.

    PubMed

    Lee, Shao-Hsuan; Hsiao, Tzu-Yu; Lee, Guo-She

    2015-06-01

    Sustained vocalizations of vowels [a], [i], and syllable [mə] were collected in twenty normal-hearing individuals. On vocalizations, five conditions of different audio-vocal feedback were introduced separately to the speakers including no masking, wearing supra-aural headphones only, speech-noise masking, high-pass noise masking, and broad-band-noise masking. Power spectral analysis of vocal fundamental frequency (F0) was used to evaluate the modulations of F0 and linear-predictive-coding was used to acquire first two formants. The results showed that while the formant frequencies were not significantly shifted, low-frequency modulations (<3 Hz) of F0 significantly increased with reduced audio-vocal feedback across speech sounds and were significantly correlated with auditory awareness of speakers' own voices. For sustained speech production, the motor speech controls on F0 may depend on a feedback mechanism while articulation should rely more on a feedforward mechanism. Power spectral analysis of F0 might be applied to evaluate audio-vocal control for various hearing and neurological disorders in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Frequency Response of Synthetic Vocal Fold Models with Linear and Nonlinear Material Properties

    PubMed Central

    Shaw, Stephanie M.; Thomson, Scott L.; Dromey, Christopher; Smith, Simeon

    2014-01-01

    Purpose The purpose of this study was to create synthetic vocal fold models with nonlinear stress-strain properties and to investigate the effect of linear versus nonlinear material properties on fundamental frequency during anterior-posterior stretching. Method Three materially linear and three materially nonlinear models were created and stretched up to 10 mm in 1 mm increments. Phonation onset pressure (Pon) and fundamental frequency (F0) at Pon were recorded for each length. Measurements were repeated as the models were relaxed in 1 mm increments back to their resting lengths, and tensile tests were conducted to determine the stress-strain responses of linear versus nonlinear models. Results Nonlinear models demonstrated a more substantial frequency response than did linear models and a more predictable pattern of F0 increase with respect to increasing length (although range was inconsistent across models). Pon generally increased with increasing vocal fold length for nonlinear models, whereas for linear models, Pon decreased with increasing length. Conclusions Nonlinear synthetic models appear to more accurately represent the human vocal folds than linear models, especially with respect to F0 response. PMID:22271874

  1. Control of voice fundamental frequency in speaking versus singing

    NASA Astrophysics Data System (ADS)

    Natke, Ulrich; Donath, Thomas M.; Kalveram, Karl Th.

    2003-03-01

    In order to investigate control of voice fundamental frequency (F0) in speaking and singing, 24 adults had to utter the nonsense word ['ta:tatas] repeatedly, while in selected trials their auditory feedback was frequency-shifted by 100 cents downwards. In the speaking condition the target speech rate and prosodic pattern were indicated by a rhythmic sequence made of white noise. In the singing condition the sequence consisted of piano notes, and subjects were instructed to match the pitch of the notes. In both conditions a response in voice F0 begins with a latency of about 150 ms. As predicted, response magnitude is greater in the singing condition (66 cents) than in the speaking condition (47 cents). Furthermore the singing condition seems to prolong the after-effect which is a continuation of the response in trials after the frequency shift. In the singing condition, response magnitude and the ability to match the target F0 correlate significantly. Results support the view that in speaking voice F0 is monitored mainly supra-segmentally and controlled less tightly than in singing.

  2. Control of voice fundamental frequency in speaking versus singing.

    PubMed

    Natke, Ulrich; Donath, Thomas M; Kalveram, Karl Th

    2003-03-01

    In order to investigate control of voice fundamental frequency (F0) in speaking and singing, 24 adults had to utter the nonsense word ['ta:tatas] repeatedly, while in selected trials their auditory feedback was frequency-shifted by 100 cents downwards. In the speaking condition the target speech rate and prosodic pattern were indicated by a rhythmic sequence made of white noise. In the singing condition the sequence consisted of piano notes, and subjects were instructed to match the pitch of the notes. In both conditions a response in voice F0 begins with a latency of about 150 ms. As predicted, response magnitude is greater in the singing condition (66 cents) than in the speaking condition (47 cents). Furthermore the singing condition seems to prolong the after-effect which is a continuation of the response in trials after the frequency shift. In the singing condition, response magnitude and the ability to match the target F0 correlate significantly. Results support the view that in speaking voice F0 is monitored mainly supra-segmentally and controlled less tightly than in singing.

  3. Precision atomic spectroscopy for improved limits on variation of the fine structure constant and local position invariance.

    PubMed

    Fortier, T M; Ashby, N; Bergquist, J C; Delaney, M J; Diddams, S A; Heavner, T P; Hollberg, L; Itano, W M; Jefferts, S R; Kim, K; Levi, F; Lorini, L; Oskay, W H; Parker, T E; Shirley, J; Stalnaker, J E

    2007-02-16

    We report tests of local position invariance and the variation of fundamental constants from measurements of the frequency ratio of the 282-nm 199Hg+ optical clock transition to the ground state hyperfine splitting in 133Cs. Analysis of the frequency ratio of the two clocks, extending over 6 yr at NIST, is used to place a limit on its fractional variation of <5.8x10(-6) per change in normalized solar gravitational potential. The same frequency ratio is also used to obtain 20-fold improvement over previous limits on the fractional variation of the fine structure constant of |alpha/alpha|<1.3x10(-16) yr-1, assuming invariance of other fundamental constants. Comparisons of our results with those previously reported for the absolute optical frequency measurements in H and 171Yb+ vs other 133Cs standards yield a coupled constraint of -1.5x10(-15)

  4. Amplification of Reynolds number dependent processes by wave distortion. [acoustic instability of liquid propellant rocket engines

    NASA Technical Reports Server (NTRS)

    Ventrice, M. B.; Fang, J. C.; Purdy, K. R.

    1975-01-01

    A system using a hot-wire transducer as an analog of a liquid droplet of propellant was employed to investigate the ingredients of the acoustic instability of liquid-propellant rocket engines. It was assumed that the combustion process was vaporization-limited and that the combustion chamber was acoustically similar to a closed-closed right-circular cylinder. Before studying the hot-wire closed-loop system (the analog system), a microphone closed-loop system, which used the response of a microphone as the source of a linear feedback exciting signal, was investigated to establish the characteristics of self-sustenance of acoustic fields. Self-sustained acoustic fields were found to occur only at resonant frequencies of the chamber. In the hot-wire closed-loop system, the response of hot-wire anemometer was used as the source of the feedback exciting signal. The self-sustained acoustic fields which developed in the system were always found to be harmonically distorted and to have as their fundamental frquency a resonant frequency for which there also existed a second resonant frequency which was approximately twice the fundamental frequency.

  5. ERP Correlates of Pitch Error Detection in Complex Tone and Voice Auditory Feedback with Missing Fundamental

    PubMed Central

    Behroozmand, Roozbeh; Korzyukov, Oleg; Larson, Charles R.

    2012-01-01

    Previous studies have shown that the pitch of a sound is perceived in the absence of its fundamental frequency (F0), suggesting that a distinct mechanism may resolve pitch based on a pattern that exists between harmonic frequencies. The present study investigated whether such a mechanism is active during voice pitch control. ERPs were recorded in response to +200 cents pitch shifts in the auditory feedback of self-vocalizations and complex tones with and without the F0. The absence of the fundamental induced no difference in ERP latencies. However, a right-hemisphere difference was found in the N1 amplitudes with larger responses to complex tones that included the fundamental compared to when it was missing. The P1 and N1 latencies were shorter in the left hemisphere, and the N1 and P2 amplitudes were larger bilaterally for pitch shifts in voice and complex tones compared with pure tones. These findings suggest hemispheric differences in neural encoding of pitch in sounds with missing fundamental. Data from the present study suggest that the right cortical auditory areas, thought to be specialized for spectral processing, may utilize different mechanisms to resolve pitch in sounds with missing fundamental. The left hemisphere seems to perform faster processing to resolve pitch based on the rate of temporal variations in complex sounds compared with pure tones. These effects indicate that the differential neural processing of pitch in the left and right hemispheres may enable the audio-vocal system to detect temporal and spectral variations in the auditory feedback for vocal pitch control. PMID:22386045

  6. Detection of NMR signals with a radio-frequency atomic magnetometer.

    PubMed

    Savukov, I M; Seltzer, S J; Romalis, M V

    2007-04-01

    We demonstrate detection of proton NMR signals with a radio-frequency (rf) atomic magnetometer tuned to the NMR frequency of 62 kHz. High-frequency operation of the atomic magnetometer makes it relatively insensitive to ambient magnetic field noise. We obtain magnetic field sensitivity of 7 fT/Hz1/2 using only a thin aluminum shield. We also derive an expression for the fundamental sensitivity limit of a surface inductive pick-up coil as a function of frequency and find that an atomic rf magnetometer is intrinsically more sensitive than a coil of comparable size for frequencies below about 50 MHz.

  7. Uncertainty quantification of voice signal production mechanical model and experimental updating

    NASA Astrophysics Data System (ADS)

    Cataldo, E.; Soize, C.; Sampaio, R.

    2013-11-01

    The aim of this paper is to analyze the uncertainty quantification in a voice production mechanical model and update the probability density function corresponding to the tension parameter using the Bayes method and experimental data. Three parameters are considered uncertain in the voice production mechanical model used: the tension parameter, the neutral glottal area and the subglottal pressure. The tension parameter of the vocal folds is mainly responsible for the changing of the fundamental frequency of a voice signal, generated by a mechanical/mathematical model for producing voiced sounds. The three uncertain parameters are modeled by random variables. The probability density function related to the tension parameter is considered uniform and the probability density functions related to the neutral glottal area and the subglottal pressure are constructed using the Maximum Entropy Principle. The output of the stochastic computational model is the random voice signal and the Monte Carlo method is used to solve the stochastic equations allowing realizations of the random voice signals to be generated. For each realization of the random voice signal, the corresponding realization of the random fundamental frequency is calculated and the prior pdf of this random fundamental frequency is then estimated. Experimental data are available for the fundamental frequency and the posterior probability density function of the random tension parameter is then estimated using the Bayes method. In addition, an application is performed considering a case with a pathology in the vocal folds. The strategy developed here is important mainly due to two things. The first one is related to the possibility of updating the probability density function of a parameter, the tension parameter of the vocal folds, which cannot be measured direct and the second one is related to the construction of the likelihood function. In general, it is predefined using the known pdf. Here, it is constructed in a new and different manner, using the own system considered.

  8. Parametrically excited multidegree-of-freedom systems with repeated frequencies

    NASA Astrophysics Data System (ADS)

    Nayfeh, A. H.

    1983-05-01

    An analysis is presented of the linear response of multidegree-of-freedom systems with a repeated frequency of order three to a harmonic parametric excitation. The method of multiple scales is used to determine the modulation of the amplitudes and phases for two cases: fundamental resonance of the modes with the repeated frequency and combination resonance involving these modes and another mode. Conditions are then derived for determining the stability of the motion.

  9. Laboratory submillimeter transition frequencies of Li-7H and Li-6H. [used for abundance investigations in red giant stars

    NASA Technical Reports Server (NTRS)

    Plummer, G. M.; Herbst, E.; De Lucia, F. C.

    1984-01-01

    The fundamental (J = 1 - 0) rotational transition frequencies of Li-7H and Li-6H in their ground (v = 0) vibrational states and of Li-7H in its first excited (v = 1) vibrational state have been measured in the laboratory. Use of these transition frequencies should permit astronomical investigations of LiH abundances in red giant stars of high lithium abundance.

  10. Shear Wave Velocity, Depth to Bedrock, and Fundamental Resonance Applied to Bedrock Mapping using MASW and H/V Analysis

    NASA Astrophysics Data System (ADS)

    Gonsiewski, J.

    2015-12-01

    Mapping bedrock depth is useful for earthquake hazard analysis, subsurface water transport, and other applications. Recently, collaborative experimentation provided an opportunity to explore a mapping method. Near surface glacial till shear wave velocity (Vs) where data is available from an array of 3-component seismometers were studied for this experiment. Vs is related to depth to bedrock (h) and fundamental resonance (Fo); Fo = Vs/(4h). The H/V spectral peak frequency of recordings from a 3-component seismometer yields a fundamental resonance estimate. Where a suitable average Vs is established, the depth to bedrock can be calculated at every seismometer. 3-component seismometer data was provided by Spectraseis. Geophones, seismographs, and an extra 3-component seismometer were provided by Wright State University for this study. For Vs analysis, three MASW surveys were conducted near the seismometer array. SurfSeis3© was used for processing MASW data. Overtones from complicated bedrock structure and great bedrock depth are improved by combining overtones from multiple source offsets from each survey. From MASW Vs and depth to bedrock results, theoretical fundamental resonance (Fo) was calculated and compared with the H/V peak spectral frequency measured by a seismometer at selected sites and processed by Geopsy processing software. Calculated bedrock depths from all geophysical data were compared with measured bedrock depths at nearby water wells and oil and gas wells provided by ODNR. Vs and depth to bedrock results from MASW produced similar calculated fundamental resonances to the H/V approximations by respective seismometers. Bedrock mapping was performed upon verifying the correlation between the theoretical fundamental resonance and H/V peak frequencies. Contour maps were generated using ArcGIS®. Contour lines interpolated from local wells were compared with the depths calculated from H/V analysis. Bedrock depths calculated from the seismometer array correlate with the major trends indicated by the surrounding wells. A final contour map was developed from depth to bedrock measured by all wells and depths calculated from the average Vs and estimated resonance at select Spectraseis 3-component seismometers.

  11. A high repetition rate multiwavelength polarized solid state laser source for long range lidar applications

    NASA Astrophysics Data System (ADS)

    Sudheer, S. K.; Pillai, V. P. Mahadevan; Nayar, V. U.

    2006-12-01

    Advances in Laser Technology and nonlinear Optical techniques can be effectively utilized for LIDAR applications in space and atmospheric sciences to achieve better flexibility and control of the available optical power. Using such devices, one can achieve highly accurate and resolved, measurement of the distribution for atmospheric scattering layers. In the present investigation a diode double end pumped high repetition rate, multi wavelength Nd:YAG laser is designed, fabricated and various laser beam parameters have been characterized for LIDAR applications. Nonlinear optical techniques have been employed to generate higher harmonics like 532nm, 355nm and 266nm for various spectral studies. The experimental setup mainly consists of two Fiber coupled pump laser diodes (Model FAP- 81-30C-800B, Coherent Inc, USA) with a maximum output power of 30Watt at a wavelength of 807-810nm at 30°C set temperature. A second harmonic LBO crystal cut for critical phase matching placed within the laser resonator is provided for converting a fraction of the fundamental beam to a second harmonic beam. A type II frequency tripling LBO nonlinear crystal (cut for critical phase matching) is also located inside the laser resonator. The third harmonic beam and the unconverted fundamental beam are then directed across a type I fourth harmonic LBO crystal cut for critical phase matching where a portion of the fundamental beam and a portion of the third harmonic beam are converted to a fourth harmonic frequency when both fundamental and third harmonic beams propagate through the frequency quadrupling crystal. The resulting beams which are the fundamental (1064nm), second harmonic (532nm), third harmonic (355nm) and fourth harmonic (266nm) are then directed to a fourth harmonic separator in which the fourth harmonic beam is separated from the fundamental beam. A maximum average power of 12W at 1064nm, 8W at 532nm, 5W at 355nm and 3W at 266nm have been measured at a repetition rate of 10KHz. A minimum pulse width of 25ns have been observed.

  12. Effects of age on F0 discrimination and intonation perception in simulated electric and electroacoustic hearing.

    PubMed

    Souza, Pamela; Arehart, Kathryn; Miller, Christi Wise; Muralimanohar, Ramesh Kumar

    2011-02-01

    Recent research suggests that older listeners may have difficulty processing information related to the fundamental frequency (F0) of voiced speech. In this study, the focus was on the mechanisms that may underlie this reduced ability. We examined whether increased age resulted in decreased ability to perceive F0 using fine-structure cues provided by the harmonic structure of voiced speech sounds or cues provided by high-rate envelope fluctuations (periodicity). Younger listeners with normal hearing and older listeners with normal to near-normal hearing completed two tasks of F0 perception. In the first task (steady state F0), the fundamental frequency difference limen (F0DL) was measured adaptively for synthetic vowel stimuli. In the second task (time-varying F0), listeners relied on variations in F0 to judge intonation of synthetic diphthongs. For both tasks, three processing conditions were created: eight-channel vocoding that preserved periodicity cues to F0; a simulated electroacoustic stimulation condition, which consisted of high-frequency vocoder processing combined with a low-pass-filtered portion, and offered both periodicity and fine-structure cues to F0; and an unprocessed condition. F0 difference limens for steady state vowel sounds and the ability to discern rising and falling intonations were significantly worse in the older subjects compared with the younger subjects. For both older and younger listeners, scores were lowest for the vocoded condition, and there was no difference in scores between the unprocessed and electroacoustic simulation conditions. Older listeners had difficulty using periodicity cues to obtain information related to talker fundamental frequency. However, performance was improved by combining periodicity cues with (low frequency) acoustic information, and that strategy should be considered in individuals who are appropriate candidates for such processing. For cochlear implant candidates, this effect might be achieved by partial electrode insertion providing acoustic stimulation in the low frequencies or by the combination of a traditional implant in one ear and a hearing aid in the opposite ear.

  13. A more fundamental approach to the derivation of nonlinear acoustic wave equations with fractional loss operators (L).

    PubMed

    Prieur, Fabrice; Vilenskiy, Gregory; Holm, Sverre

    2012-10-01

    A corrected derivation of nonlinear wave propagation equations with fractional loss operators is presented. The fundamental approach is based on fractional formulations of the stress-strain and heat flux definitions but uses the energy equation and thermodynamic identities to link density and pressure instead of an erroneous fractional form of the entropy equation as done in Prieur and Holm ["Nonlinear acoustic wave equations with fractional loss operators," J. Acoust. Soc. Am. 130(3), 1125-1132 (2011)]. The loss operator of the obtained nonlinear wave equations differs from the previous derivations as well as the dispersion equation, but when approximating for low frequencies the expressions for the frequency dependent attenuation and velocity dispersion remain unchanged.

  14. Correlation analysis of the physiological factors controlling fundamental voice frequency.

    PubMed

    Atkinson, J E

    1978-01-01

    A technique has been developed to obtain a quantitative measure of correlation between electromyographic (EMG) activity of various laryngeal muscles, subglottal air pressure, and the fundamental frequency of vibration of the vocal folds (Fo). Data were collected and analyzed on one subject, a native speaker of American English. The results show that an analysis of this type can provide a useful measure of correlation between the physiological and acoustical events in speech and, furthermore, can yield detailed insights into the organization and nature of the speech production process. In particular, based on these results, a model is suggested of Fo control involving laryngeal state functions that seems to agree with present knowledge of laryngeal control and experimental evidence.

  15. Radial oscillations and stability of compact stars in Eddington-inspired Born-Infeld gravity

    NASA Astrophysics Data System (ADS)

    Sham, Y.-H.; Lin, L.-M.; Leung, P. T.

    2012-09-01

    We study the hydrostatic equilibrium structure of compact stars in the Eddington-inspired Born-Infeld gravity recently proposed by Bañados and Ferreira [Phys. Rev. Lett. 105, 011101 (2010)]. We also develop a framework to study the radial perturbations and stability of compact stars in this theory. We find that the standard results of stellar stability still hold in this theory. The frequency square of the fundamental oscillation mode vanishes for the maximum-mass stellar configuration. The dependence of the oscillation mode frequencies on the coupling parameter κ of the theory is also investigated. We find that the fundamental mode is insensitive to the value of κ, while higher-order modes depend more strongly on κ.

  16. Stability of rigid rotors supported by air foil bearings: Comparison of two fundamental approaches

    NASA Astrophysics Data System (ADS)

    Larsen, Jon S.; Santos, Ilmar F.; von Osmanski, Sebastian

    2016-10-01

    High speed direct drive motors enable the use of Air Foil Bearings (AFB) in a wide range of applications due to the elimination of gear forces. Unfortunately, AFB supported rotors are lightly damped, and an accurate prediction of their Onset Speed of Instability (OSI) is therefore important. This paper compares two fundamental methods for predicting the OSI. One is based on a nonlinear time domain simulation and another is based on a linearised frequency domain method and a perturbation of the Reynolds equation. Both methods are based on equivalent models and should predict similar results. Significant discrepancies are observed leading to the question, is the classical frequency domain method sufficiently accurate? The discrepancies and possible explanations are discussed in detail.

  17. Fundamental frequency development in typically developing infants and infants with severe-to-profound hearing loss

    PubMed Central

    Iyer, Suneeti Nathani; Oller, D. Kimbrough

    2010-01-01

    Little research has been conducted on the development of suprasegmental characteristics of vocalizations in typically developing infants (TDI) and the role of audition in the development of these characteristics. The purpose of the present study was to examine the longitudinal development of fundamental frequency (F0) in eight TDI and eight infants with severe-to-profound hearing loss matched for level of vocal development. Results revealed no significant changes in F0 with advances in pre-language vocal development for TDI. Infants with hearing loss, however, showed a statistically reliable higher variability of F0 than TDI, when age was accounted for as a covariate. The results suggest development of F0 may be strongly influenced by audition. PMID:19031191

  18. Microwave bulk-acoustic-wave reflection-grating resonators.

    PubMed

    Oates, D E; Pan, J Y

    1988-01-01

    A technique for fabrication of bulk-acoustic-wave (BAW) resonators operating at fundamental frequencies between 1 and 10 GHz is presented. The resonators utilize a reflection grating made by optical holographic methods in iron-doped lithium niobate. Q factors of 30000 at 1 GHz have been demonstrated. Extension to Q of 10000 at 10 GHz appears feasible. Projected limitations to performance are discussed. The high Q at the high fundamental frequency directly results in low-phase noise. Phase-noise measurements of BAW resonator-stabilized oscillators operating at 1.14 GHz are presented. The single-sideband noise floor of <-140 dBc/Hz is shown to be in agreement with an analytical model. Projected improvements in the devices and circuits promise performance of <-160 dBc/Hz.

  19. Use of an untuned cavity for absolute power measurements of the harmonics above 100 GHz from an IMPATT oscillator

    NASA Astrophysics Data System (ADS)

    Llewellyn-Jones, D. T.; Knight, R. J.; Gebbie, H. A.

    1980-07-01

    A new technique of measuring absolute power exploiting an untuned cavity and Fourier spectroscopy has been used to examine the power spectrum of the harmonics and other overtones produced by a 95 GHz IMPATT oscillator. The conditions which favor the production of a rich harmonic spectrum are not those which maximize the fundamental power. Under some conditions of mismatch at the fundamental frequency it is possible to produce over 200 microW of harmonic power in the 100-200 GHz region comparable with the fundamental power from the oscillator.

  20. Differences between vocalization evoked by social stimuli in feral cats and house cats.

    PubMed

    Yeon, Seong C; Kim, Young K; Park, Se J; Lee, Scott S; Lee, Seung Y; Suh, Euy H; Houpt, Katherine A; Chang, Hong H; Lee, Hee C; Yang, Byung G; Lee, Hyo J

    2011-06-01

    To investigate how socialization can affect the types and characteristics of vocalization produced by cats, feral cats (n=25) and house cats (n=13) were used as subjects, allowing a comparison between cats socialized to people and non-socialized cats. To record vocalization and assess the cats' responses to behavioural stimuli, five test situations were used: approach by a familiar caretaker, by a threatening stranger, by a large doll, by a stranger with a dog and by a stranger with a cat. Feral cats showed extremely aggressive and defensive behaviour in most test situations, and produced higher call rates than those of house cats in the test situations, which could be attributed to less socialization to other animals and to more sensitivity to fearful situations. Differences were observed in the acoustic parameters of feral cats in comparison to those of house cats. The feral cat produced significantly higher frequency in fundamental frequency, peak frequency, 1st quartile frequency, 3rd quartile frequency of growls and hisses in agonistic test situations. In contrast to the growls and hisses, in meow, all acoustic parameters like fundamental frequency, first formant, peak frequency, 1st quartile frequency, and 3rd quartile frequency of house cats were of significantly higher frequency than those of feral cats. Also, house cats produced calls of significantly shorter in duration than feral cats in agonistic test situations. These results support the conclusion that a lack of socialization may affect usage of types of vocalizations, and the vocal characteristics, so that the proper socialization of cat may be essential to be a suitable companion house cat. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Scaling of Yb-Fiber Frequency Combs

    NASA Astrophysics Data System (ADS)

    Ruehl, Axel; Marcinkevicius, Andrius; Fermann, Martin E.; Hartl, Ingmar

    2010-06-01

    Immediately after their introduction in 1999, femtosecond laser frequency combs revolutionized the field of precision optical frequency metrology and are key elements in many experiments. Frequency combs based on femtosecond Er-fiber lasers based were demonstrated in 2005, allowing additionally rugged, compact set-ups and reliable unattended long-term operation. The introduction of Yb-fiber technology led to an dramatic improvement in fiber-comb performance in various aspects. Low-noise Yb-fiber femtosecond oscillators enabled a reduction of relative comb tooth linewidth to the sub-Hz level as well as scaling of the fundamental comb spacings up to 1 GHz. This is beneficial for any frequency-domain comb application due to the higher power per comb-mode. Many spectroscopic applications require, however, frequency combs way beyond the wavelength range accessible with broad band laser materials, so nonlinear conversion and hence higher peak intensity is required. We demonstrated power scaling of Yb-fiber frequency combs up to 80 W average power in a strictly linear chirped-pulse amplification schemes compatible with low-noise phase control. These high-power Yb-fiber-frequency combs facilitated not only the extension to the mid-IR spectral region. When coupled to a passive enhancement cavity, the average power can be further scaled to the kW-level opening new capabilities for XUV frequency combs via high-harmonic generation. All these advances of fiber-based frequency combs will trigger many novel applications both in fundamental and applied sciences. Schibli et al., Nature Photonics 2 355 (2008). Hartl et al., MF9 in Advanced Solid-State Photonics. 2009, Optical Society of America. Ruehl et al., AWC7 in Advanced Solid-State Photonics. 2010, Optical Society of America. Adler et al., Optics Letters 34 1330 (2009). Yost et al., Nature Physics 5 815 (2009).

  2. Chip-Scale Architectures for Precise Optical Frequency Synthesis

    NASA Astrophysics Data System (ADS)

    Yang, Jinghui

    Scientists and engineers have investigated various types of stable and accurate optical synthesizers, where mode-locked laser based optical frequency comb synthesizers have been widely investigated. These frequency combs bridge the frequencies from optical domain to microwave domain with orders of magnitude difference, providing a metrological tool for various platforms. The demand for highly robust, scalable, compact and cost-effective femtosecond-laser synthesizers, however, are of great importance for applications in air- or space-borne platforms, where low cost and rugged packaging are particularly required. This has been afforded in the past several years due to breakthroughs in chip-scale nanofabrication, bringing advances in optical frequency combs down to semiconductor chips. These platforms, with significantly enhanced light-matter interaction, provide a fertile sandbox for research rich in nonlinear dynamics, and offer a reliable route towards low-phase noise photonic oscillators, broadband optical frequency synthesizers, miniaturized optical clockwork, and coherent terabit communications. The dissertation explores various types of optical frequency comb synthesizers based on nonlinear microresonators. Firstly, the fundamental mechanism of mode-locking in a high-quality factor microresonator is examined, supported by ultrafast optical characterizations, analytical closed-form solutions and numerical modeling. In the evolution of these frequency microcombs, the key nonlinear dynamical effect governing the comb state coherence is rigorously analyzed. Secondly, a prototype of chip-scale optical frequency synthesizer is demonstrated, with the laser frequency comb stabilized down to instrument-limited 50-mHz RF frequency inaccuracies and 10-16 fractional frequency inaccuracies, near the fundamental limits. Thirdly, a globally stable Turing pattern is achieved and characterized in these nonlinear resonators with high-efficiency conversion, subsequently generating coherent high-power terahertz radiation via plasmonic photomixers. Finally, a new universal modality of frequency combs is discussed, including satellite states, dynamical tunability, and high efficiency conversion towards direct chip-scale optical frequency synthesis at the precision metrology frontiers.

  3. Site effects and soil-structure resonance study in the Kobarid basin (NW Slovenia) using microtremors

    NASA Astrophysics Data System (ADS)

    Gosar, A.

    2010-04-01

    The town of Kobarid is located in one of three areas with the highest seismic hazard in Slovenia. It was hit by several 1976-1977 Friuli sequence earthquakes and recently by the 1998 and 2004 Krn Mountains earthquakes which caused damage of intensity up to VII EMS-98 scale. The town is located in a small basin filled with heterogeneous glaciofluvial Quaternary sediments in which site effects due to soft sediments are expected. The existing microzonation which is based on surface geological data only is inadequate, and no borehole or geophysical data are available in the basin that would allow a modelling approach of site effects assessment. The microtremor horizontal-to-vertical spectral ratio (HVSR) method was therefore applied in order to assess the fundamental frequency of the sediments. Investigations were performed on a 100×100 m dense grid and 106 free-field measurements acquired. Clear HVSR peaks were obtained in the majority of the surveyed area. The eastern part of the basin is characterized by two well separated peaks which indicate distinct shallow and deep impedance contrasts. The iso-frequency map of sediments shows a distribution in a broad range of 1.8-22.2 Hz. The observed frequencies can be related to the total thickness of Quaternary sediments (sand, gravel) in the western part of the basin only. They are deposited over bedrock built of Cretaceous flysch. In the eastern part the obtained fundamental frequencies are influenced by the presence of a shallow conglomerate layer inside sandy gravel or lacustrine chalk. The extent of these layers was not known before. Microtremor measurements were also performed inside 19 characteristic buildings of various heights (from two to four stories), and longitudinal and transverse fundamental frequencies determined from amplitude spectra. A potential of soil-structure resonance was assessed by comparing building frequencies with the free-field sediments frequencies derived from the iso-frequency map. For two surveyed buildings a high danger of soil-structure resonance was assessed and for three buildings the danger was of medium level. The building resonant frequency of two- and three-story houses, which prevail in the area, spans the range 4-11 Hz, with an average value of 7.7 Hz. The danger of soil-structure resonance should be therefore sought in this frequency range. Since the majority of Kobarid area is characterized by lower (W part) or higher (E part) frequencies, the danger exist mainly in a relatively narrow transition zone.

  4. Wideband tunable 140 GHz second-harmonic InP-TED oscillator

    NASA Astrophysics Data System (ADS)

    Rydberg, A.; Kollberg, E.

    1986-07-01

    A second-harmonic InP-TED oscillator, with an output power of more than 3 dBm at 144 GHz and tunable over a 10 percent frequency range, has been developed. The design incorporates two waveguide resonators. One resonator determines the fundamental frequency of oscillation and the other optimizes the second-harmonic output power.

  5. Resting and Task-Modulated High-Frequency Brain Rhythms Measured by Scalp Encephalography in Infants with Tuberous Sclerosis Complex

    ERIC Educational Resources Information Center

    Stamoulis, Catherine; Vogel-Farley, Vanessa; Degregorio, Geneva; Jeste, Shafali S.; Nelson, Charles A.

    2015-01-01

    The electrophysiological correlates of cognitive deficits in tuberous sclerosis complex (TSC) are not well understood, and modulations of neural dynamics by neuroanatomical abnormalities that characterize the disorder remain elusive. Neural oscillations (rhythms) are a fundamental aspect of brain function, and have dominant frequencies in a wide…

  6. Coupling Ocean Models and Satellite Derived Optical Fields to Estimate LIDAR Penetration and Detection Performance

    DTIC Science & Technology

    2012-01-01

    34Laser oscillations in nd-doped yttrium aluminum , yttrium gallium and gadolinium garnets ," Applied Physics Letters (10): 182. doi:10.1063/1.1753928...Aluminium Garnet ) Nd:YAG lasers, and inherent of this material is its fundamental 1064nm frequency that is frequency doubled to 532 nm to penetrate

  7. [Objective study of the voice quality following partial laryngectomy].

    PubMed

    Remacle, M; Millet, B

    1991-01-01

    The high resolution frequency analyzer is used for the study of the vocal quality after partial laryngectomy. The post-operative plot after speech therapy is of good quality when respecting one vocal fold. On the contrary, the heard vocal sound does not correspond to the harmonics of the fundamental frequency but to intense noise from irregular vibrations of the residual laryngeal mucosa (ventricular folds, arytenoids). High resolution frequency analysis contributes to the follow-up of the partial laryngectomy.

  8. [Period-tripling in Multiscale Physical and Biological Events].

    PubMed

    Bondar, A T; Fedorov, M V; Kolombet, V A

    2015-01-01

    A recent paper by S.J. Puetz et al. (Chaos, Solitons -& Fractals, v. 62-63, p. 55, 2014) described a fundamental period-tripled model. It involves periods of different astronomical (quasars, Sun), geophysical (geomagnetic, climatic, volcanic) and some biological processes. This work contains statistics for sixteen pairs of a period-tripled sequence. These periods range from -50 years to 1.5 billion years and no signs of the timescale limitations are found. We believe that the universal scope of the fundamental period-tripled model can be used for the development of new methodology of research data analysis: the main idea is that the spectrum of the periods of the studied event should be tested for the similarity with the spectrum of fundamental period-tripling pattern (because of the fundamental nature of the period-tripled model). Using this method, in this study we complement an already described period-tripled model with periods of human memory performance ranging from one minute to one month also adding seven relevant periods/frequencies of the period-tripled model in the range of human hearing. We make a conclusion that these characteristic frequencies may form the basis for music and singing phenomena. The new methodology is particularly appropriate for being applied in medicine and engineering.

  9. High-frequency polarization dynamics in spin-lasers: pushing the limits

    NASA Astrophysics Data System (ADS)

    Gerhardt, Nils C.; Lindemann, Markus; Pusch, Tobias; Michalzik, Rainer; Hofmann, Martin R.

    2017-09-01

    While the high-frequency performance of conventional lasers is limited by the coupled carrier-photon dynamics, spin-polarized lasers have a high potential to overcome this limitation and to push the direct modulation bandwidth beyond 100 GHz. The key is to utilize the ultrafast polarization dynamics in spin-polarized vertical cavity surface-emitting lasers (spin-VCSELs) which is decoupled from the intensity dynamics and its fundamental limitations. The polarization dynamics in such devices, characterized by the polarization oscillation resonance frequency, is mainly determined by the amount of birefringence in the cavity. Using an approach for manipulating the birefringence via mechanical strain we were able to increase the polarization dynamics to resonance frequencies of more than 40 GHz. Up to now these values are only limited by the setup to induce birefringence and do not reflect any fundamental limitations. Taking our record results for the birefringence-induced mode splitting of more than 250 GHz into account, the concept has the potential to provide polarization modulation in spin-VCSELs with modulation frequencies far beyond 100 GHz. This makes them ideal devices for next-generation fast optical interconnects. In this paper we present experimental results for ultrafast polarization dynamics up to 50 GHz and compare them to numerical simulations.

  10. Volitional exaggeration of body size through fundamental and formant frequency modulation in humans

    PubMed Central

    Pisanski, Katarzyna; Mora, Emanuel C.; Pisanski, Annette; Reby, David; Sorokowski, Piotr; Frackowiak, Tomasz; Feinberg, David R.

    2016-01-01

    Several mammalian species scale their voice fundamental frequency (F0) and formant frequencies in competitive and mating contexts, reducing vocal tract and laryngeal allometry thereby exaggerating apparent body size. Although humans’ rare capacity to volitionally modulate these same frequencies is thought to subserve articulated speech, the potential function of voice frequency modulation in human nonverbal communication remains largely unexplored. Here, the voices of 167 men and women from Canada, Cuba, and Poland were recorded in a baseline condition and while volitionally imitating a physically small and large body size. Modulation of F0, formant spacing (∆F), and apparent vocal tract length (VTL) were measured using Praat. Our results indicate that men and women spontaneously and systemically increased VTL and decreased F0 to imitate a large body size, and reduced VTL and increased F0 to imitate small size. These voice modulations did not differ substantially across cultures, indicating potentially universal sound-size correspondences or anatomical and biomechanical constraints on voice modulation. In each culture, men generally modulated their voices (particularly formants) more than did women. This latter finding could help to explain sexual dimorphism in F0 and formants that is currently unaccounted for by sexual dimorphism in human vocal anatomy and body size. PMID:27687571

  11. Fundamental frequency discrimination and speech perception in noise in cochlear implant simulationsa)

    PubMed Central

    Carroll, Jeff; Zeng, Fan-Gang

    2007-01-01

    Increasing the number of channels at low frequencies improves discrimination of fundamental frequency (F0) in cochlear implants [Geurts and Wouters 2004]. We conducted three experiments to test whether improved F0 discrimination can be translated into increased speech intelligibility in noise in a cochlear implant simulation. The first experiment measured F0 discrimination and speech intelligibility in quiet as a function of channel density over different frequency regions. The results from this experiment showed a tradeoff in performance between F0 discrimination and speech intelligibility with a limited number of channels. The second experiment tested whether improved F0 discrimination and optimizing this tradeoff could improve speech performance with a competing talker. However, improved F0 discrimination did not improve speech intelligibility in noise. The third experiment identified the critical number of channels needed at low frequencies to improve speech intelligibility in noise. The result showed that, while 16 channels below 500 Hz were needed to observe any improvement in speech intelligibility in noise, even 32 channels did not achieve normal performance. Theoretically, these results suggest that without accurate spectral coding, F0 discrimination and speech perception in noise are two independent processes. Practically, the present results illustrate the need to increase the number of independent channels in cochlear implants. PMID:17604581

  12. Modal and thermal analysis of Les Arches unstable rock column (Vercors massif, French Alps)

    NASA Astrophysics Data System (ADS)

    Bottelin, P.; Lévy, C.; Baillet, L.; Jongmans, D.; Guéguen, P.

    2013-08-01

    A potentially unstable limestone column (˜1000 m3, Vercors, French Alps) delineated by an open rear fracture was continuously instrumented with two three-component seismic sensors from mid-May 2009 to mid-October 2011. Spectral analysis of seismic noise allowed several resonance frequencies to be determined, ranging from 6 to 21 Hz. The frequency domain decomposition (FDD) technique was applied to the ambient vibrations recorded on the top of the rock column. Three vibration modes were identified at 6, 7.5 and 9 Hz, describing the upper part of corresponding modal shapes. Finite element numerical modelling of the column dynamic response confirmed that the first two modes are bending modes perpendicular and parallel to the fracture, respectively, while the third one corresponds to torsion. Seismic noise monitoring also pointed out that resonance frequencies fluctuate with time, under thermomechanical control. For seasonal cycles, changes in frequency are due to the variations of the bulk elastic properties with temperature. At daily scale, increase in fundamental frequency with temperature has been interpreted as resulting from the rock expansion inducing a closure of the rear fracture rock bridges, hence stiffening the contact between the column and the rock mass. Conversely, the rock contraction induces a fracture opening and a decrease in resonance frequency. In winter, when the temperature drops below 0 °C, a dramatic increase in fundamental frequency is observed from 6 Hz to more than 25 Hz, resulting from ice formation in the fracture. During spring, the resonance frequency gradually diminishes with ice melting to reach the value measured before winter.

  13. Design of air blast pressure sensors based on miniature silicon membrane and piezoresistive gauges

    NASA Astrophysics Data System (ADS)

    Riondet, J.; Coustou, A.; Aubert, H.; Pons, P.; Lavayssière, M.; Luc, J.; Lefrançois, A.

    2017-11-01

    Available commercial piezoelectric pressure sensors are not able to accurately reproduce the ultra-fast transient pressure occurring during an air blast experiment. In this communication a new pressure sensor prototype based on a miniature silicon membrane and piezoresistive gauges is reported for significantly improving the performances in terms of time response. Simulation results demonstrate the feasibility of a pressure transducer having a fundamental resonant frequency almost ten times greater than the commercial piezoelectric sensors one. The sensor uses a 5μm-thick SOI membrane and four P-type silicon gauges (doping level ≅ 1019 at/cm3) in Wheatstone bridge configuration. To obtain a good trade-off between the fundamental mechanical resonant frequency and pressure sensitivity values, the typical dimension of the rectangular membrane is fixed to 30μm x 90μm with gauge dimension of 1μm x 5μm. The achieved simulated mechanical resonant frequency of these configuration is greater than 40MHz with a sensitivity of 0.04% per bar.

  14. A clock network for geodesy and fundamental science

    PubMed Central

    Lisdat, C.; Grosche, G.; Quintin, N.; Shi, C.; Raupach, S.M.F.; Grebing, C.; Nicolodi, D.; Stefani, F.; Al-Masoudi, A.; Dörscher, S.; Häfner, S.; Robyr, J.-L.; Chiodo, N.; Bilicki, S.; Bookjans, E.; Koczwara, A.; Koke, S.; Kuhl, A.; Wiotte, F.; Meynadier, F.; Camisard, E.; Abgrall, M.; Lours, M.; Legero, T.; Schnatz, H.; Sterr, U.; Denker, H.; Chardonnet, C.; Le Coq, Y.; Santarelli, G.; Amy-Klein, A.; Le Targat, R.; Lodewyck, J.; Lopez, O; Pottie, P.-E.

    2016-01-01

    Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10−17 via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10−17 is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second. PMID:27503795

  15. Effect of artificially lengthened vocal tract on vocal fold oscillation's fundamental frequency.

    PubMed

    Hanamitsu, Masakazu; Kataoka, Hideyuki

    2004-06-01

    The fundamental frequency of vocal fold oscillation (F(0)) is controlled by laryngeal mechanics and aerodynamic properties. F(0) change per unit change of transglottal pressure (dF/dP) using a shutter valve has been studied and found to have nonlinear, V-shaped relationship with F(0). On the other hand, the vocal tract is also known to affect vocal fold oscillation. This study examined the effect of artificially lengthened vocal tract length on dF/dP. dF/dP was measured in six men using two mouthpieces of different lengths. The dF/dP graph for the longer vocal tract was shifted leftward relative to the shorter one. Using the one-mass model, the nadir of the "V" on the dF/dP graph was strongly influenced by the resonance around the first formant frequency. However, a more precise model is needed to account for the effects of viscosity and turbulence.

  16. Modeling complex tone perception: grouping harmonics with combination-sensitive neurons.

    PubMed

    Medvedev, Andrei V; Chiao, Faye; Kanwal, Jagmeet S

    2002-06-01

    Perception of complex communication sounds is a major function of the auditory system. To create a coherent precept of these sounds the auditory system may instantaneously group or bind multiple harmonics within complex sounds. This perception strategy simplifies further processing of complex sounds and facilitates their meaningful integration with other sensory inputs. Based on experimental data and a realistic model, we propose that associative learning of combinations of harmonic frequencies and nonlinear facilitation of responses to those combinations, also referred to as "combination-sensitivity," are important for spectral grouping. For our model, we simulated combination sensitivity using Hebbian and associative types of synaptic plasticity in auditory neurons. We also provided a parallel tonotopic input that converges and diverges within the network. Neurons in higher-order layers of the network exhibited an emergent property of multifrequency tuning that is consistent with experimental findings. Furthermore, this network had the capacity to "recognize" the pitch or fundamental frequency of a harmonic tone complex even when the fundamental frequency itself was missing.

  17. Changes in speaking fundamental frequency characteristics with aging.

    PubMed

    Nishio, Masaki; Niimi, Seiji

    2008-01-01

    Changes in speaking fundamental frequency (SFF) associated with aging were studied in a total of 374 healthy normal speakers (187 males and 187 females) from adolescent to older age groups. Participants were asked to read a sample passage aloud, and acoustic analysis was performed. The main results were as follows: (1) Males exhibited no significant trend for SFF changes in aging. However, a slight increase was observed in participants aged 70 years or older. (2) Females in their 30s and 40s showed obviously lower frequencies than those in their 20s. Across all age groups, including the 80s, SFF tended to decrease markedly in association with aging. (3) The degree of SFF change in association with aging was much larger in females than in males. In addition, reference intervals (mean +/- 1.96 SD) obtained for males and females in each age group are considered useful for clinical detection of abnormalities of SFF, as well as for detection of laryngeal diseases causing SFF abnormality. 2008 S. Karger AG, Basel.

  18. High accuracy line positions of the ν1 fundamental band of 14N216O

    NASA Astrophysics Data System (ADS)

    AlSaif, Bidoor; Lamperti, Marco; Gatti, Davide; Laporta, Paolo; Fermann, Martin; Farooq, Aamir; Lyulin, Oleg; Campargue, Alain; Marangoni, Marco

    2018-05-01

    The ν1 fundamental band of N2O is examined by a novel spectrometer that relies on the frequency locking of an external-cavity quantum cascade laser around 7.8 μm to a near-infrared Tm:based frequency comb at 1.9 μm. Due to the large tunability, nearly 70 lines in the 1240-1310 cm-1 range of the ν1 band of N2O, from P(40) to R(31), are for the first time measured with an absolute frequency calibration and an uncertainty from 62 to 180 kHz, depending on the line. Accurate values of the spectroscopic constants of the upper state are derived from a fit of the line centers (rms ≈ 4.8 × 10-6 cm-1 or 144 kHz). The ν1 transitions presently measured in a Doppler regime validate high accuracy predictions based on sub-Doppler measurements of the ν3 and ν3-ν1 transitions.

  19. A clock network for geodesy and fundamental science.

    PubMed

    Lisdat, C; Grosche, G; Quintin, N; Shi, C; Raupach, S M F; Grebing, C; Nicolodi, D; Stefani, F; Al-Masoudi, A; Dörscher, S; Häfner, S; Robyr, J-L; Chiodo, N; Bilicki, S; Bookjans, E; Koczwara, A; Koke, S; Kuhl, A; Wiotte, F; Meynadier, F; Camisard, E; Abgrall, M; Lours, M; Legero, T; Schnatz, H; Sterr, U; Denker, H; Chardonnet, C; Le Coq, Y; Santarelli, G; Amy-Klein, A; Le Targat, R; Lodewyck, J; Lopez, O; Pottie, P-E

    2016-08-09

    Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.

  20. Relationship of physical activity to fundamental movement skills among adolescents.

    PubMed

    Okely, A D; Booth, M L; Patterson, J W

    2001-11-01

    To determine the relationship of participation in organized and nonorganized physical activity with fundamental movement skills among adolescents. Male and female children in Grade 8 (mean age, 13.3 yr) and Grade 10 (mean age, 15.3 yr) were assessed on six fundamental movement skills (run, vertical jump, catch, overhand throw, forehand strike, and kick). Physical activity was assessed using a self-report recall measure where students reported the type, duration, and frequency of participation in organized physical activity and nonorganized physical activity during a usual week. Multiple regression analysis indicated that fundamental movement skills significantly predicted time in organized physical activity, although the percentage of variance it could explain was small. This prediction was stronger for girls than for boys. Multiple regression analysis showed no relationship between time in nonorganized physical activity and fundamental movement skills. Fundamental movement skills are significantly associated with adolescents' participation in organized physical activity, but predict only a small portion of it.

  1. The Impact of Temperature and Body Size on Fundamental Flight Tone Variation in the Mosquito Vector Aedes aegypti (Diptera: Culicidae): Implications for Acoustic Lures.

    PubMed

    Villarreal, Susan M; Winokur, Olivia; Harrington, Laura

    2017-09-01

    Aedes aegypti (L.) males use female flight tone as a means of mate localization. By playing the sound of a flying female, males can be attracted to a trap to monitor mosquito populations and the progress of transgenic male releases. However, the female flight tone used to attract males needs to be optimized to maximize trap effectiveness. The fundamental frequency of female flight tone could be influenced by both body size and ambient temperature. However, no analysis yet has considered both the effect of body size and temperature on female flight tone of Ae. aegypti. Here, we present results for both these factors by recording the sounds of free-flying and tethered females across multiple temperature environments and with females reared for small, medium, and large body sizes. We demonstrate that female fundamental frequency is highly dependent on the environmental temperature, increasing ∼8-13 Hz with each °C gain. Body size and whether a female was tethered or free-flying did not impact the relationship between frequency and temperature, although further analysis is warranted. Our study highlights the importance of understanding the relationship between flight tone and temperature, and will inform the design of male mosquito traps. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America.

  2. The nature of noise wavefield and its applications for site effects studies: A literature review

    NASA Astrophysics Data System (ADS)

    Bonnefoy-Claudet, Sylvette; Cotton, Fabrice; Bard, Pierre-Yves

    2006-12-01

    The aim of this paper is to discuss the existing scientific literature in order to gather all the available information dealing with the origin and the nature of the ambient seismic noise wavefield. This issue is essential as the use of seismic noise is more and more popular for seismic hazard purposes with a growing number of processing techniques based on the assumption that the noise wavefield is predominantly consisting of fundamental mode Rayleigh waves. This survey reveals an overall agreement about the origin of seismic noise and its frequency dependence. At frequencies higher than 1 Hz, seismic noise systematically exhibits daily and weekly variations linked to human activities, whereas at lower frequencies (between 0.005 and 0.3 Hz) the variation of seismic noise is correlated to natural activities (oceanic, meteorological…). Such a surface origin clearly supports the interpretation of seismic noise wavefield consisting primarily of surface waves. However, the further, very common (though hidden) assumption according which almost all the noise energy would be carried by fundamental mode Rayleigh waves is not supported by the few available data: no "average" number can though be given concerning the actual proportion between surface and body waves, Love and Rayleigh waves (horizontal components), fundamental and higher modes (vertical components), since the few available investigations report a significant variability, which might be related with site conditions and noise source properties.

  3. Quantifying the impact of androgen therapy on the female larynx.

    PubMed

    Damrose, Edward J

    2009-02-01

    To describe the timing of changes in fundamental frequency of the female voice following androgen therapy during female to male gender reassignment. A 33-year-old female semi-professional singer undergoing gender reassignment and intramuscular androgen injections was examined at monthly intervals to monitor the impact of therapy on the voice. Laryngostroboscopy and acoustic analysis were performed simultaneously to monitor for potential laryngeal pathology. Pretreatment mean fundamental frequency (MF(0)) was 228.45 Hz and ranged from 140.26 Hz to 430.64 Hz. Between month 3 and month 4 of treatment, MF(0) declined to 116.52 Hz and ranged from 90.75 Hz to 201.07 Hz. Shimmer increased from 3.4% to 7.8%. Noise to harmonics ratio (NHR) also increased from 0.12 to 0.17. The patient has continued to sing semi-professionally despite these changes in laryngeal function. Androgen therapy exerted a profound change on mean fundamental frequency between the third and fourth months of treatment. In addition, pitch range was reduced in a commensurate fashion. Patients undergoing androgen therapy may undergo a significant change in speaking voice between the third and fourth months of therapy. Moreover, though these changes may exert a profound impact on the singing voice, patients undergoing gender reassignment may still be able to achieve personal and professional success in their singing careers.

  4. Frequency modulation indicator, Arnold’s web and diffusion in the Stark Quadratic-Zeeman problem

    NASA Astrophysics Data System (ADS)

    Cordani, Bruno

    2008-11-01

    We notice that the fundamental frequencies of a slightly perturbed integrable Hamiltonian system are not time-constant inside a resonance but frequency modulated, as is evident from pendulum models and wavelet analysis. Exploiting an intrinsic imprecision inherent to the numerical frequency analysis algorithm itself, hence transforming a drawback into an opportunity, we define the Frequency Modulation Indicator, a very sensitive tool in detecting where fundamental frequencies are modulated, localizing so the resonances without having to resort, as in other methods, to the integration of variational equations. For the Kepler problem, the space of the orbits with a fixed energy has the topology of the product of two 2-spheres. The perturbation Hamiltonian, averaged over the mean anomaly, has surely a maximum and a minimum, to which correspond two periodic orbits in physical space. Studying the neighbourhood of these two elliptic stable points, we are able to define adapted action-angle variables, for example, the usual but “SO(4)-rotated” Delaunay variables. The procedure, implemented in the program KEPLER, is performed transparently for the user, providing a general scheme suited for generic perturbation. The method is then applied to the Stark-Quadratic-Zeeman problem, displaying very clearly the Arnold web of the resonances. Sectioning transversely one of the resonance strips so highlighted and performing a numerical frequency analysis, one is able to locate with great precision the thin stochastic layer surrounding a separatrix. Another very long (10 8 revolutions) frequency analysis on an orbit starting here reveals, as expected, a well defined pattern, which ensures that the integration errors do not eject the point out of the layer, and moreover a very slow drift in the frequency values, clearly due to Arnold diffusion.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bacon, L. D.

    Hybrid Band{trademark} (H-band) is a Lockheed Martin Missiles and Fire Control (LMMFC) designation for a specific RF modulation that causes disruption of select electronic components and circuits. H-Band enables conventional high-power microwave (HPM) effects (with a center frequency of 1 to 2 GHz, for example) using a higher frequency carrier signal. The primary technical objective of this project was to understand the fundamental physics of Hybrid Band{trademark} Radio Frequency effects on electronic systems. The follow-on objective was to develop and validate a Hybrid Band{trademark} effects analysis process.

  6. Nonlinear response of a harmonic diatomic molecule: Algebraic nonperturbative calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Recamier, Jose; Mochan, W. Luis; Maytorena, Jesus A.

    2005-08-15

    Even harmonic molecules display a nonlinear behavior when driven by an inhomogeneous field. We calculate the response of single harmonic molecules to a monochromatic time and space dependent electric field E(r,t) of frequency {omega} employing exact algebraic methods. We evaluate the responses at the fundamental frequency {omega} and at successive harmonics 2{omega}, 3{omega}, etc., as a function of the intensity and of the frequency of the field and compare the results with those of first and second order perturbation theory.

  7. Proceedings of the Annual Symposium on Frequency Control (45th) held in Los Angeles, California on May 29 -31, 1991

    DTIC Science & Technology

    1991-05-31

    Corporation High Precision Nonlinear Computer Modelling Technique for Quartz Crystal Oscillators ............... 341 R. Brendel, F. Djian, CNRS & E. Robert...34) A.1.5% IV.1 Results of the computations for resonators having circular electrodes. The model was applied to compute the resonances 0f-.I frequencies...having circular electrodes. *- I The model was applied to compute the resonances frequencies of the fundamental mode and of its anharmonics ,odel and

  8. Determination and Comparison of Carbonyl Stretching Frequency of a Ketone in Its Ground State and the First Electronic Excited State

    ERIC Educational Resources Information Center

    Bandyopadhyay, Subhajit; Roy, Saswata

    2014-01-01

    This paper describes an inexpensive experiment to determine the carbonyl stretching frequency of an organic keto compound in its ground state and first electronic excited state. The experiment is simple to execute, clarifies some of the fundamental concepts of spectroscopy, and is appropriate for a basic spectroscopy laboratory course. The…

  9. Response of a hypersonic boundary layer to freestream pulse acoustic disturbance.

    PubMed

    Wang, Zhenqing; Tang, Xiaojun; Lv, Hongqing

    2014-01-01

    The response of hypersonic boundary layer over a blunt wedge to freestream pulse acoustic disturbance was investigated. The stability characteristics of boundary layer for freestream pulse wave and continuous wave were analyzed comparatively. Results show that freestream pulse disturbance changes the thermal conductivity characteristics of boundary layer. For pulse wave, the number of main disturbance clusters decreases and the frequency band narrows along streamwise. There are competition and disturbance energy transfer among different modes in boundary layer. The dominant mode of boundary layer has an inhibitory action on other modes. Under continuous wave, the disturbance modes are mainly distributed near fundamental and harmonic frequencies, while under pulse wave, the disturbance modes are widely distributed in different modes. For both pulse and continuous waves, most of disturbance modes slide into a lower-growth or decay state in downstream, which is tending towards stability. The amplitude of disturbance modes in boundary layer under continuous wave is considerably larger than pulse wave. The growth rate for the former is also considerably larger than the later the disturbance modes with higher growth are mainly distributed near fundamental and harmonic frequencies for the former, while the disturbance modes are widely distributed in different frequencies for the latter.

  10. Response of a Hypersonic Boundary Layer to Freestream Pulse Acoustic Disturbance

    PubMed Central

    Wang, Zhenqing; Tang, Xiaojun; Lv, Hongqing

    2014-01-01

    The response of hypersonic boundary layer over a blunt wedge to freestream pulse acoustic disturbance was investigated. The stability characteristics of boundary layer for freestream pulse wave and continuous wave were analyzed comparatively. Results show that freestream pulse disturbance changes the thermal conductivity characteristics of boundary layer. For pulse wave, the number of main disturbance clusters decreases and the frequency band narrows along streamwise. There are competition and disturbance energy transfer among different modes in boundary layer. The dominant mode of boundary layer has an inhibitory action on other modes. Under continuous wave, the disturbance modes are mainly distributed near fundamental and harmonic frequencies, while under pulse wave, the disturbance modes are widely distributed in different modes. For both pulse and continuous waves, most of disturbance modes slide into a lower-growth or decay state in downstream, which is tending towards stability. The amplitude of disturbance modes in boundary layer under continuous wave is considerably larger than pulse wave. The growth rate for the former is also considerably larger than the later the disturbance modes with higher growth are mainly distributed near fundamental and harmonic frequencies for the former, while the disturbance modes are widely distributed in different frequencies for the latter. PMID:24737993

  11. Fundamental frequency estimation of singing voice

    NASA Astrophysics Data System (ADS)

    de Cheveigné, Alain; Henrich, Nathalie

    2002-05-01

    A method of fundamental frequency (F0) estimation recently developped for speech [de Cheveigné and Kawahara, J. Acoust. Soc. Am. (to be published)] was applied to singing voice. An electroglottograph signal recorded together with the microphone provided a reference by which estimates could be validated. Using standard parameter settings as for speech, error rates were low despite the wide range of F0s (about 100 to 1600 Hz). Most ``errors'' were due to irregular vibration of the vocal folds, a sharp formant resonance that reduced the waveform to a single harmonic, or fast F0 changes such as in high-amplitude vibrato. Our database (18 singers from baritone to soprano) included examples of diphonic singing for which melody is carried by variations of the frequency of a narrow formant rather than F0. Varying a parameter (ratio of inharmonic to total power) the algorithm could be tuned to follow either frequency. Although the method has not been formally tested on a wide range of instruments, it seems appropriate for musical applications because it is accurate, accepts a wide range of F0s, and can be implemented with low latency for interactive applications. [Work supported by the Cognitique programme of the French Ministry of Research and Technology.

  12. Properies of the microseism wave field in Australia from three component array data

    NASA Astrophysics Data System (ADS)

    Gal, Martin; Reading, Anya; Ellingsen, Simon; Koper, Keith; Burlacu, Relu; Tkalčić, Hrvoje

    2016-04-01

    In the last two decades, ambient noise studies in the range of 1-20 seconds have predominantly focused on the analysis of source regions for Rayleigh and P waves. The theoretical excitation of these phases is well understood for primary microseisms (direct coupling of gravity waves in sloping shallow bathymetry) and secondary microseisms (wave-wave interaction) and correlates well with observations. For Love waves, the excitation mechanism in the secondary microseism band is to date unknown. It has been shown, that LQ waves can exhibit larger amplitudes than Rg waves for certain frequencies. Therefore detailed analysis of the wave field are necessary to find indications on the generation mechanism. We analyse data from two spiral-shaped arrays located in Australia, the Pilbara Array (PSAR) in the North-West and an array in South Queensland (SQspa) in the East. The two arrays are different in aperture and allow for the study of primary and secondary microseisms with SQspa and higher secondary microseisms with PSAR. We use a deconvolution enhanced beamforming approach, which is based on the CLEAN algorithm. It allows the accurate detection of weaker sources and the estimation of power levels on each component or wave type. For PSAR we evaluate 1 year of data in the frequency range of 0.35-1 Hz and find fundamental and higher mode Rg and LQ waves. For the low end of the frequency range, we find the strongest fundamental mode Rg waves to originate from multiple direction, but confined to coastline reflectors, i.e. coastlines that are perpendicular to the main swell direction, while higher mode Rg waves are mainly generated in the Great Australian Bight. For higher frequencies, the source locations of Rg waves move toward the north coast, which is closest to the array and we see an increase in the Lg phase. The majority of fundamental LQ waves are generated at the west coast of Australia and we find some agreement between low frequency Rg and LQ source locations, which becomes uncorrelated with increasing frequency. For higher mode LQ waves the generation region is in the south-west, where Australia is exposed to direct swells from the Antarctic. In the case of Rg-to-LQ power ratio, we find a frequency and backazimuth dependence. Results from SQspa allow lower frequency arrivals around the primary and secondary microseism peak to be investigated.

  13. Long distance measurement with a femtosecond laser based frequency comb

    NASA Astrophysics Data System (ADS)

    Bhattacharya, N.; Cui, M.; Zeitouny, M. G.; Urbach, H. P.; van den Berg, S. A.

    2017-11-01

    Recent advances in the field of ultra-short pulse lasers have led to the development of reliable sources of carrier envelope phase stabilized femtosecond pulses. The pulse train generated by such a source has a frequency spectrum that consists of discrete, regularly spaced lines known as a frequency comb. In this case both the frequency repetition and the carrier-envelope-offset frequency are referenced to a frequency standard, like an atomic clock. As a result the accuracy of the frequency standard is transferred to the optical domain, with the frequency comb as transfer oscillator. These unique properties allow the frequency comb to be applied as a versatile tool, not only for time and frequency metrology, but also in fundamental physics, high-precision spectroscopy, and laser noise characterization. The pulse-to-pulse phase relationship of the light emitted by the frequency comb has opened up new directions for long range highly accurate distance measurement.

  14. Subtle flickering in Cepheids: Kepler and MOST

    NASA Astrophysics Data System (ADS)

    Evans, Nancy Remage; Szabó, Robert; Szabados, Laszlo; Derekas, Aliz; Matthews, Jaymie M.; Cameron, Chris; the MOST Team

    2014-02-01

    Fundamental mode classical Cepheids have light curves which repeat accurately enough that we can watch them evolve (change period). The new level of accuracy and quantity of data with the Kepler and MOST satellites probes this further. An intriguing result was found in the long time-series of Kepler data for V1154 Cyg the one classical Cepheid (fundamental mode, P = 4.9 d) in the field, which has short term changes in period (~=20 minutes), correlated for ~=10 cycles (period jitter). To follow this up, we obtained a month long series of observations of the fundamental mode Cepheid RT Aur and the first overtone pulsator SZ Tau. RT Aur shows the traditional strict repetition of the light curve, with the Fourier amplitude ratio R 1/R 2 remaining nearly constant. The light curve of SZ Tau, on the other hand, fluctuates in amplitude ratio at the level of approximately 50%. Furthermore prewhitening the RT Aur data with 10 frequencies reduces the Fourier spectrum to noise. For SZ Tau, considerable power is left after this prewhitening in a complicated variety of frequencies.

  15. Ionospheric limitations to time transfer by satellite

    NASA Technical Reports Server (NTRS)

    Knowles, S. H.

    1983-01-01

    The ionosphere can contribute appreciable group delay and phase change to radio signals traversing it; this can constitute a fundamental limitation to the accuracy of time and frequency measurements using satellites. Because of the dispersive nature of the ionosphere, the amount of delay is strongly frequency-dependent. Ionospheric compensation is necessary for the most precise time transfer and frequency measurements, with a group delay accuracy better than 10 nanoseconds. A priori modeling is not accurate to better than 25%. The dual-frequency compensation method holds promise, but has not been rigorously experimentally tested. Irregularities in the ionosphere must be included in the compensation process.

  16. Thermal Noise Limit in Frequency Stabilization of Lasers with Rigid Cavities

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Kemery, Amy; Camp, Jordan

    2004-01-01

    We evaluated thermal noise (Brownian motion) in a rigid reference cavity used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with t.he direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency- reference cavity of order 1 Hz/square root Hz(0.01 Hz/square root Hz) at 10 mHz (100 Hz) at room temperature. This level coincides with the world-highest level stabilization results.

  17. Temperature and frequency dependent mean free paths of renormalized phonons in nonlinear lattices

    NASA Astrophysics Data System (ADS)

    Li, Nianbei; Liu, Junjie; Wu, Changqin; Li, Baowen

    2018-02-01

    Unraveling general properties of renormalized phonons are of fundamental relevance to the heat transport in the regime of strong nonlinearity. In this work, we directly study the temperature and frequency dependent mean free path (MFP) of renormalized phonons with the newly developed numerical tuning fork method. The typical 1D nonlinear lattices such as Fermi-Pasta-Ulam β lattice and {φ }4 lattice are investigated in detail. Interestingly, it is found that the MFPs are inversely proportional to the frequencies of renormalized phonons rather than the square of phonon frequencies predicted by existing phonon scattering theory.

  18. Fundamental constants and tests of theory in Rydberg states of hydrogenlike ions.

    PubMed

    Jentschura, Ulrich D; Mohr, Peter J; Tan, Joseph N; Wundt, Benedikt J

    2008-04-25

    A comparison of precision frequency measurements to quantum electrodynamics (QED) predictions for Rydberg states of hydrogenlike ions can yield information on values of fundamental constants and test theory. With the results of a calculation of a key QED contribution reported here, the uncertainty in the theory of the energy levels is reduced to a level where such a comparison can yield an improved value of the Rydberg constant.

  19. Flying qualities and control system characteristics for superaugmented aircraft

    NASA Technical Reports Server (NTRS)

    Myers, T. T.; Mcruer, D. T.; Johnston, D. E.

    1984-01-01

    Aircraft-alone dynamics and superaugmented control system fundamental regulatory properties including stability and regulatory responses of the basic closed-loop systems; fundamental high and low frequency margins and governing factors; and sensitivity to aircraft and controller parameters are addressed. Alternative FCS mechanizations, and mechanizational side effects are also discussed. An overview of flying qualities considerations encompasses general pilot operations as a controller in unattended, intermittent and trim, and full-attention regulatory or command control; effective vehicle primary and secondary response properties to pilot inputs and disturbances; pilot control architectural possibilities; and comparison of superaugmented and conventional aircraft path responses for different forms of pilot control. Results of a simple experimental investigation into pilot dynamic behavior in attitude control of superaugmented aircraft configurations with high frequency time laps and time delays are presented.

  20. Nonlinear Oscillators in Space Physics

    NASA Technical Reports Server (NTRS)

    Lester,Daniel; Thronson, Harley

    2011-01-01

    We discuss dynamical systems that produce an oscillation without an external time dependent source. Numerical results are presented for nonlinear oscillators in the Em1h's atmosphere, foremost the quasi-biennial oscillation (QBOl. These fluid dynamical oscillators, like the solar dynamo, have in common that one of the variables in a governing equation is strongly nonlinear and that the nonlinearity, to first order, has particular form. of 3rd or odd power. It is shown that this form of nonlinearity can produce the fundamental li'equency of the internal oscillation. which has a period that is favored by the dynamical condition of the fluid. The fundamental frequency maintains the oscillation, with no energy input to the system at that particular frequency. Nonlinearities of 2nd or even power could not maintain the oscillation.

  1. Continuous-wave, single-frequency 229  nm laser source for laser cooling of cadmium atoms.

    PubMed

    Kaneda, Yushi; Yarborough, J M; Merzlyak, Yevgeny; Yamaguchi, Atsushi; Hayashida, Keitaro; Ohmae, Noriaki; Katori, Hidetoshi

    2016-02-15

    Continuous-wave output at 229 nm for the application of laser cooling of Cd atoms was generated by the fourth harmonic using two successive second-harmonic generation stages. Employing a single-frequency optically pumped semiconductor laser as a fundamental source, 0.56 W of output at 229 nm was observed with a 10-mm long, Brewster-cut BBO crystal in an external cavity with 1.62 W of 458 nm input. Conversion efficiency from 458 nm to 229 nm was more than 34%. By applying a tapered amplifier (TA) as a fundamental source, we demonstrated magneto-optical trapping of all stable Cd isotopes including isotopes Cd111 and Cd113, which are applicable to optical lattice clocks.

  2. Pressure Gain Combustion for Gas Turbines

    DTIC Science & Technology

    2013-08-20

    reveal the fundamental fluid mechanics of these unsteady flows. Specifically investigated were the effects of the geometry, jet Mach number, frequency...and  numerical  simulations  to  reveal  the  fundamental   fluid  mechanics of these unsteady flows.  Specifically we investigate the effects of the...simplified geometry so that the  fundamental  physical  mechanisms can be understood. This allow an  informed redesign of the turbine to work efficiently  with

  3. Contrast-enhanced transcranial two-dimensional ultrasound imaging using shear-mode conversion at low frequency.

    PubMed

    Lucht, Benjamin; Hubbell, Austin; Hynynen, Kullervo

    2013-02-01

    The distortion and attenuation of transcranial ultrasound (US) signals are significant problems in US imaging of the brain. Of the variety of proposed solutions, shear-mode transmission through the skull is one of the more recent options and has been shown to reduce distortion of the US beam. This study examined the effects of transcranial shear-mode transmission on the images of a contrast-agent-filled polytetrafluoroethylene tube produced by a 32-element 750 kHz linear phased array transducer through an ex vivo human skull section. Although the tube was successfully imaged using shear-mode transmission with subharmonic imaging in 6 of 9 cases, the tube was visible in only 1 of 9 cases for both the fundamental and the second harmonic frequencies. Some improvement in the location of the axial image was seen at the fundamental frequency using shear mode. No improvement was seen at the other two frequencies, but this may be due to low transducer sensitivity. As well, neither the presence of the skull nor the incident angle changed the distance at which signals from the two tubes could be resolved. With this transducer, these distances were found to be 5 mm laterally and 3 mm axially for the fundamental and second harmonic images, and 10 mm and 5 mm for the subharmonic images. The results show that the subharmonic signal was the most successful of the three examined in penetrating a thick skull but that the success comes at the cost of image resolution. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Efficient second-harmonic conversion of CW single-frequency Nd:YAG laser light by frequency locking to a monolithic ring frequency doubler

    NASA Technical Reports Server (NTRS)

    Gerstenberger, D. C.; Tye, G. E.; Wallace, R. W.

    1991-01-01

    Efficient second-harmonic conversion of the 1064-nm output of a diode-pumped CW single-frequency Nd:YAG laser to 532 nm was obtained by frequency locking the laser to a monolithic ring resonator constructed of magnesium-oxide-doped lithium niobate. The conversion efficiency from the fundamental to the second harmonic was 65 percent. Two hundred milliwatts of CW single-frequency 532-nm light were produced from 310 mW of power of 1064-nm light. This represents a conversion efficiency of 20 percent from the 1-W diode laser used to pump the Nd:YAG laser to single-frequency 532-nm output. No signs of degradation were observed for over 500 h of operation.

  5. Characterization of site conditions for selected seismic stations in eastern part of Romania

    NASA Astrophysics Data System (ADS)

    Grecu, B.; Zaharia, B.; Diaconescu, M.; Bala, A.; Nastase, E.; Constantinescu, E.; Tataru, D.

    2018-02-01

    Strong motion data are essential for seismic hazard assessment. To correctly understand and use this kind of data is necessary to have a good knowledge of local site conditions. Romania has one of the largest strong motion networks in Europe with 134 real-time stations. In this work, we aim to do a comprehensive site characterization for eight of these stations located in the eastern part of Romania. We make use of a various seismological dataset and we perform ambient noise and earthquake-based investigations to estimate the background noise level, the resonance frequencies and amplification of each site. We also derive the Vs30 parameter from the surface shear-wave velocity profiles obtained through the inversion of the Rayleigh waves recorded in active seismic measurements. Our analyses indicate similar results for seven stations: high noise levels for frequencies larger than 1 Hz, well defined fundamental resonance at low frequencies (0.15-0.29 Hz), moderate amplification levels (up to 4 units) for frequencies between 0.15 and 5-7 Hz and same soil class (type C) according to the estimated Vs30 and Eurocode 8. In contrast, the eighth station for which the soil class is evaluated of type B exhibits a very good noise level for a wide range of frequencies (0.01-20 Hz), a broader fundamental resonance at high frequencies ( 8 Hz) and a flat amplification curve between 0.1 and 3-4 Hz.

  6. Split-Waveguide Mounts For Submillimeter-Wave Multipliers And Harmonic Mixers

    NASA Technical Reports Server (NTRS)

    Raisanen, Antti; Choudhury, Debabani; Dengler, Robert J.; Oswald, John E.; Siegel, Peter H.

    1996-01-01

    Novel variation of split-waveguide mount for millimeter-and submillimeter-wavelength frequency multipliers and harmonic mixers developed. Designed to offer wide range of available matching impedances, while maintaining relatively simple fabrication sequence. Wide tuning range achieved with separate series and parallel elements, consisting of two pairs of noncontacting sliding backshorts, at fundamental and harmonic frequencies. Advantages include ease of fabrication, reliability, and tunability.

  7. Detailed Design of the Rigidizable Inflatable Get-Away-Special Experiment

    DTIC Science & Technology

    2006-03-23

    velocity determination, shown in Equation 4.1: V = ALF 2πfn + √ 2aSd (4.1) where ALF = Low Frequency Acceleration (m/s 2) fn = First Fundamental Frequency...Information The first equation in SSP 52005 is used to determine the velocity of the com- ponent to be contained: V = ALF 2πfn + √ 2aSd (C.1) where ALF = Low

  8. Unsteady transonic flows - Introduction, current trends, applications

    NASA Technical Reports Server (NTRS)

    Yates, E. C., Jr.

    1985-01-01

    The computational treatment of unsteady transonic flows is discussed, reviewing the historical development and current techniques. The fundamental physical principles are outlined; the governing equations are introduced; three-dimensional linearized and two-dimensional linear-perturbation theories in frequency domain are described in detail; and consideration is given to frequency-domain FEMs and time-domain finite-difference and integral-equation methods. Extensive graphs and diagrams are included.

  9. Effects of age on F0-discrimination and intonation perception in simulated electric and electro-acoustic hearing

    PubMed Central

    Souza, Pamela; Arehart, Kathryn; Miller, Christi Wise; Muralimanohar, Ramesh Kumar

    2010-01-01

    Objectives Recent research suggests that older listeners may have difficulty processing information related to the fundamental frequency (F0) of voiced speech. In this study, the focus was on the mechanisms that may underlie this reduced ability. We examined whether increased age resulted in decreased ability to perceive F0 using fine structure cues provided by the harmonic structure of voiced speech sounds and/or cues provided by high-rate envelope fluctuations (periodicity). Design Younger listeners with normal hearing and older listeners with normal to near-normal hearing completed two tasks of F0 perception. In the first task (steady-state F0), the fundamental frequency difference limen (F0DL) was measured adaptively for synthetic vowel stimuli. In the second task (time-varying F0), listeners relied on variations in F0 to judge intonation of synthetic diphthongs. For both tasks, three processing conditions were created: 8-channel vocoding which preserved periodicity cues to F0; a simulated electroacoustic stimulation condition, which consisted of high-frequency vocoder processing combined with a low-pass filtered portion, and offered both periodicity and fine-structure cues to F0; and an unprocessed condition. Results F0 difference limens for steady-state vowel sounds and the ability to discern rising and falling intonations were significantly worse in the older subjects compared to the younger subjects. For both older and younger listeners scores were lowest for the vocoded condition, and there was no difference in scores between the unprocessed and electroacoustic simulation conditions. Conclusions Older listeners had difficulty using periodicity cues to obtain information related to talker fundamental frequency. However, performance was improved by combining periodicity cues with (low-frequency) acoustic information, and that strategy should be considered in individuals who are appropriate candidates for such processing. For cochlear implant candidates, that effect might be achieved by partial electrode insertion providing acoustic stimulation in the low frequencies; or by the combination of a traditional implant in one ear and a hearing aid in the opposite ear. PMID:20739892

  10. Uses of the ICRF and implications for future VLBI

    NASA Technical Reports Server (NTRS)

    Ma, Chopo

    2006-01-01

    Since its inception on 1 Jan 1998, the fundamental ICRF has been set by the VLBI positions of 212 "defining" extragalactic radio sources. In all there are approx.3000 sources with usefully accurate (< few mas) positions consistent with the ICRF. The uses of the ICRF include fundamental astrometry, monitoring of Earth orientation, and spacecraft navigation. For fundamental astrometry, stability and accuracy are most important, and realizations at different frequencies must be in proper registration. However, there is no preferred frequency, and the GAIA mission has the potential for an optical ICRF with 500,000 objects at the 50 microarcsec level some time after the planned 2011 launch. The radio ICRF should be properly prepared for a transition to assure long term stability and consistency. Earth orientation monitoring requires objects attached to the solid Earth, and VLBI will continue to be the fundamental technique. For this purpose it is essential that the new VLBI stations contemplated in the VLBI20l0 report be capable of observing a sufficiently large and well-distributed set of stable sources, and identifying these sources is an on-going effort. Spacecraft navigation by differential VLBI is planned using the Ka-band telemetry signal, and work has begun towards an ICRF realization suitable for this purpose. The balancing of different needs related to the VLBI ICRF will be discussed.

  11. Joint inversion of fundamental and higher mode Rayleigh waves

    USGS Publications Warehouse

    Luo, Y.-H.; Xia, J.-H.; Liu, J.-P.; Liu, Q.-S.

    2008-01-01

    In this paper, we analyze the characteristics of the phase velocity of fundamental and higher mode Rayleigh waves in a six-layer earth model. The results show that fundamental mode is more sensitive to the shear velocities of shallow layers (< 7 m) and concentrated in a very narrow band (around 18 Hz) while higher modes are more sensitive to the parameters of relatively deeper layers and distributed over a wider frequency band. These properties provide a foundation of using a multi-mode joint inversion to define S-wave velocity. Inversion results of both synthetic data and a real-world example demonstrate that joint inversion with the damped least squares method and the SVD (Singular Value Decomposition) technique to invert Rayleigh waves of fundamental and higher modes can effectively reduce the ambiguity and improve the accuracy of inverted S-wave velocities.

  12. Poisson point process modeling for polyphonic music transcription.

    PubMed

    Peeling, Paul; Li, Chung-fai; Godsill, Simon

    2007-04-01

    Peaks detected in the frequency domain spectrum of a musical chord are modeled as realizations of a nonhomogeneous Poisson point process. When several notes are superimposed to make a chord, the processes for individual notes combine to give another Poisson process, whose likelihood is easily computable. This avoids a data association step linking individual harmonics explicitly with detected peaks in the spectrum. The likelihood function is ideal for Bayesian inference about the unknown note frequencies in a chord. Here, maximum likelihood estimation of fundamental frequencies shows very promising performance on real polyphonic piano music recordings.

  13. Tuning the frequency of ultrashort laser pulses by a cross-phase-modulation-induced shift in a photonic crystal fiber.

    PubMed

    Konorov, S O; Akimov, D A; Zheltikov, A M; Ivanov, A A; Alfimov, M V; Scalora, M

    2005-06-15

    Femtosecond pulses of fundamental Cr:forsterite laser radiation are used as a pump field to tune the frequency of copropagating second-harmonic pulses of the same laser through cross-phase modulation in a photonic crystal fiber. Sub-100-kW femtosecond pump pulses coupled into a photonic crystal fiber with an appropriate dispersion profile can shift the central frequency of the probe field by more than 100 nm, suggesting a convenient way to control propagation and spectral transformations of ultrashort laser pulses.

  14. How Internally Coupled Ears Generate Temporal and Amplitude Cues for Sound Localization.

    PubMed

    Vedurmudi, A P; Goulet, J; Christensen-Dalsgaard, J; Young, B A; Williams, R; van Hemmen, J L

    2016-01-15

    In internally coupled ears, displacement of one eardrum creates pressure waves that propagate through air-filled passages in the skull and cause displacement of the opposing eardrum, and conversely. By modeling the membrane, passages, and propagating pressure waves, we show that internally coupled ears generate unique amplitude and temporal cues for sound localization. The magnitudes of both these cues are directionally dependent. The tympanic fundamental frequency segregates a low-frequency regime with constant time-difference magnification from a high-frequency domain with considerable amplitude magnification.

  15. Multi-frequency klystron designed for high efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Aaron

    A multi-frequency klystron has an electron gun which generates a beam, a circuit of bunch-align-collect (BAC) tuned cavities that bunch the beam and amplify an RF signal, a collector where the beam is collected and dumped, and a standard output cavity and waveguide coupled to a window to output RF power at a fundamental mode to an external load. In addition, the klystron has additional bunch-align-collect (BAC) cavities tuned to a higher harmonic frequency, and a harmonic output cavity and waveguide coupled via a window to an additional external load.

  16. On-Line Laser Measurements of the Tension in Thin Fibres

    NASA Astrophysics Data System (ADS)

    Pearson, Matthew R. T.; Wiederick, H. D.; Sherritt, S.

    1996-05-01

    We have developed a non-contact method for measuring the tension in a moving nylon fibre. Experiments have been conducted primarily with thin, nylon fibres used in the industrial production of airbags, for which non-destructive tension measurements are critical for ensuring safety standards. The system relies on the standing waves produced as the nylon passes rapidly over a set of two rollers; a laser/photo- diode combination is used to monitor the vibrations between them. A Fourier analysis of the signal generated by a scan of 0.2 sec yields the fundamental frequency of vibration of the fibre. The tension in the fibre is proportional to the square of this fundamental frequency. The present system provides accurate, non-contact measurements of the tension in a moving fibre, and shows promise for industrial application.

  17. Attenuation characteristics of the fundamental modes that propagate in buried iron water pipes.

    PubMed

    Long, R; Lowe, M; Cawley, P

    2003-09-01

    The attenuation of the fundamental non-torsional modes that propagate down buried iron water pipes has been studied. The mode shapes, mode attenuation due to leakage into the surrounding medium and the scattering of the modes as they interact with pipe joints and fittings have been investigated. In the low frequency region the mode predicted to dominate over significant propagation distances approximates a plane wave in the water within the pipe. The established acoustic technique used to locate leaks in buried iron water pipes assumes that leak noise propagates as a single non-dispersive mode at a velocity related to the low frequency asymptote of this water borne mode. Experiments have been conducted on buried water mains at test sites in the UK to verify the attenuation and velocity dispersion predictions.

  18. Body mass index and acoustic voice parameters: is there a relationship.

    PubMed

    Souza, Lourdes Bernadete Rocha de; Santos, Marquiony Marques Dos

    2017-05-06

    Specific elements such as weight and body volume can interfere in voice production and consequently in its acoustic parameters, which is why it is important for the clinician to be aware of these relationships. To investigate the relationship between body mass index and the average acoustic voice parameters. Observational, cross-sectional descriptive study. The sample consisted of 84 women, aged between 18 and 40years, an average of 26.83 (±6.88). The subjects were grouped according to body mass index: 19 underweight; 23 normal ranges, 20 overweight and 22 obese and evaluated the fundamental frequency of the sustained vowel [a] and the maximum phonation time of the vowels [a], [i], [u], using PRAAT software. The data were submitted to the Kruskal-Wallis test to verify if there were differences between the groups regarding the study variables. All variables showed statistically significant results and were subjected to non-parametric test Mann-Whitney. Regarding to the average of the fundamental frequency, there was statistically significant difference between groups with underweight and overweight and obese; normal range and overweight and obese. The average maximum phonation time revealed statistically significant difference between underweight and obese individuals; normal range and obese; overweight and obese. Body mass index influenced the average fundamental frequency of overweight and obese individuals evaluated in this study. Obesity influenced in reducing maximum phonation time average. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Transgender Phonosurgery: A Systematic Review and Meta-analysis.

    PubMed

    Song, Tara Elena; Jiang, Nancy

    2017-05-01

    Objectives Different surgical techniques have been described in the literature to increase vocal pitch. The purpose of this study is to systematically review these surgeries and perform a meta-analysis to determine which technique increases pitch the most. Data Sources CINAHL, Cochrane, Embase, Medline, PubMed, and Science Direct. Review Methods A systematic review and meta-analysis of the literature was performed using the CINAHL, Cochrane, Embase, Medline, PubMed, and Science Direct databases. Studies were eligible for inclusion if they evaluated pitch-elevating phonosurgical techniques in live humans and performed pre- and postoperative acoustic analysis. Data were gathered regarding surgical technique, pre- and postoperative fundamental frequencies, perioperative care measures, and complications. Results Twenty-nine studies were identified. After applying inclusion and exclusion criteria, a total of 13 studies were included in the meta-analysis. Mechanisms of pitch elevation included increasing vocal cord tension (cricothyroid approximation), shortening the vocal cord length (cold knife glottoplasty, laser-shortening glottoplasty), and decreasing mass (laser reduction glottoplasty). The most common interventions were shortening techniques and cricothyroid approximation (6 studies each). The largest increase in fundamental frequency was seen with techniques that shortened the vocal cords. Preoperative speech therapy, postoperative voice rest, and reporting of patient satisfaction were inconsistent. Many of the studies were limited by low power and short length of follow-up. Conclusions Multiple techniques for elevation of vocal pitch exist, but vocal cord shortening procedures appear to result in the largest increase in fundamental frequency.

  20. Probing the Jet Turnover Frequency Dependence on Mass and Mass Accretion Rate

    NASA Astrophysics Data System (ADS)

    Hammerstein, Erica; Gültekin, Kayhan; King, Ashley

    2018-01-01

    We have examined a sample of 15 sub-Eddington supermassive black holes (SMBHs) in a variety of galaxy classifications to further understand the proposed fundamental plane of black hole activity and scaling relations between black hole masses and their radio and X-ray luminosities. This plane describes black holes from stellar-mass to supermassive. The physics probed by these sub-Eddington systems is thought to be a radiatively inefficient, jet-dominated accretion flow. By studying black holes in this regime, we can learn important information on the disk-jet connection for accreting black holes.A key factor in studying the fundamental plane is the turnover frequency — the frequency at which emission transitions from optically thick at lower frequencies to optically thin at higher frequencies. This turnover point can be measured by observing the source in both radio and X-ray. Our project aims to test the dependence of the turnover frequency on mass and mass accretion rate.Radio observations of the sample were obtained using the Karl G. Jansky Very Large Array (VLA) in the range of 5-40 GHz across four different frequency bands in A configuration to give the highest spatial resolution to focus on the core emission. Our carefully chosen sample of SMBHs with dynamically measured masses consists of two sub-samples: those with approximately constant mass accretion rate (LX/LEdd ~ 10‑7) and those with approximately constant mass (MBH ~ 108 Msun). X-ray data were obtained from archival Chandra observations. To find the turnover frequency, we used Markov Chain Monte Carlo methods to fit two power laws to the radio data and the archival X-ray data. The intersection of the radio and X-ray fits is the turnover frequency.We present the results for both subsamples of SMBHs and their relationship between the turnover frequency and X-ray luminosity, which we take to scale with mass accretion rate, and jet power derived from both radio and X-ray properties.

  1. Mining volume measurement system

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph Saul (Inventor)

    1988-01-01

    In a shaft with a curved or straight primary segment and smaller off-shooting segments, at least one standing wave is generated in the primary segment. The shaft has either an open end or a closed end and approximates a cylindrical waveguide. A frequency of a standing wave that represents the fundamental mode characteristic of the primary segment can be measured. Alternatively, a frequency differential between two successive harmonic modes that are characteristic of the primary segment can be measured. In either event, the measured frequency or frequency differential is characteristic of the length and thus the volume of the shaft based on length times the bore area.

  2. Optical atomic clocks

    NASA Astrophysics Data System (ADS)

    Poli, N.; Oates, C. W.; Gill, P.; Tino, G. M.

    2013-12-01

    In the last ten years extraordinary results in time and frequency metrology have been demonstrated. Frequency-stabilization techniques for continuous-wave lasers and femtosecond optical frequency combs have enabled a rapid development of frequency standards based on optical transitions in ultra-cold neutral atoms and trapped ions. As a result, today's best performing atomic clocks tick at an optical rate and allow scientists to perform high-resolution measurements with a precision approaching a few parts in 1018. This paper reviews the history and the state of the art in optical-clock research and addresses the implementation of optical clocks in a possible future redefinition of the SI second as well as in tests of fundamental physics.

  3. A Pitch Extraction Method with High Frequency Resolution for Singing Evaluation

    NASA Astrophysics Data System (ADS)

    Takeuchi, Hideyo; Hoguro, Masahiro; Umezaki, Taizo

    This paper proposes a pitch estimation method suitable for singing evaluation incorporable in KARAOKE machines. Professional singers and musicians have sharp hearing for music and singing voice. They recognize that singer's voice pitch is “a little off key” or “be in tune”. In the same way, the pitch estimation method that has high frequency resolution is necessary in order to evaluate singing. This paper proposes a pitch estimation method with high frequency resolution utilizing harmonic characteristic of autocorrelation function. The proposed method can estimate a fundamental frequency in the range 50 ∼ 1700[Hz] with resolution less than 3.6 cents in light processing.

  4. INSTRUMENTS AND METHODS OF INVESTIGATION: Spectral and spectral-frequency methods of investigating atmosphereless bodies of the Solar system

    NASA Astrophysics Data System (ADS)

    Busarev, Vladimir V.; Prokof'eva-Mikhailovskaya, Valentina V.; Bochkov, Valerii V.

    2007-06-01

    A method of reflectance spectrophotometry of atmosphereless bodies of the Solar system, its specificity, and the means of eliminating basic spectral noise are considered. As a development, joining the method of reflectance spectrophotometry with the frequency analysis of observational data series is proposed. The combined spectral-frequency method allows identification of formations with distinctive spectral features, and estimations of their sizes and distribution on the surface of atmospherelss celestial bodies. As applied to investigations of asteroids 21 Lutetia and 4 Vesta, the spectral frequency method has given us the possibility of obtaining fundamentally new information about minor planets.

  5. Quasi-supercontinuum source in the extreme ultraviolet using multiple frequency combs from high-harmonic generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wünsche, Martin; Fuchs, Silvio; Aull, Stefan

    A quasi-supercontinuum source in the extreme ultraviolet (XUV) is demonstrated using a table-top femtosecond laser and a tunable optical parametric amplifier (OPA) as a driver for high-harmonic generation (HHG). The harmonic radiation, which is usually a comb of odd multiples of the fundamental frequency, is generated by near-infrared (NIR) laser pulses from the OPA. A quasi-continuous XUV spectrum in the range of 30 to 100 eV is realized by averaging over multiple harmonic comb spectra with slightly different fundamental frequencies and thus different spectral spacing between the individual harmonics. The driving laser wavelength is swept automatically during an averaging timemore » period. With a total photon flux of 4×10 9 photons/s in the range of 30 eV to 100 eV and 1×10 7 photons/s in the range of 100 eV to 200 eV, the resulting quasi-supercontinuum XUV source is suited for applications such as XUV coherence tomography (XCT) or near-edge absorption fine structure spectroscopy (NEXAFS).« less

  6. Quasi-supercontinuum source in the extreme ultraviolet using multiple frequency combs from high-harmonic generation

    DOE PAGES

    Wünsche, Martin; Fuchs, Silvio; Aull, Stefan; ...

    2017-03-16

    A quasi-supercontinuum source in the extreme ultraviolet (XUV) is demonstrated using a table-top femtosecond laser and a tunable optical parametric amplifier (OPA) as a driver for high-harmonic generation (HHG). The harmonic radiation, which is usually a comb of odd multiples of the fundamental frequency, is generated by near-infrared (NIR) laser pulses from the OPA. A quasi-continuous XUV spectrum in the range of 30 to 100 eV is realized by averaging over multiple harmonic comb spectra with slightly different fundamental frequencies and thus different spectral spacing between the individual harmonics. The driving laser wavelength is swept automatically during an averaging timemore » period. With a total photon flux of 4×10 9 photons/s in the range of 30 eV to 100 eV and 1×10 7 photons/s in the range of 100 eV to 200 eV, the resulting quasi-supercontinuum XUV source is suited for applications such as XUV coherence tomography (XCT) or near-edge absorption fine structure spectroscopy (NEXAFS).« less

  7. An educational laboratory virtual instrumentation suite assisted experiment for studying fundamentals of series resistance-inductance-capacitance circuit

    NASA Astrophysics Data System (ADS)

    Rana, K. P. S.; Kumar, Vineet; Mendiratta, Jatin

    2017-11-01

    One of the most elementary concepts in freshmen Electrical Engineering subject comprises the Resistance-Inductance-Capacitance (RLC) circuit fundamentals, that is, their time and frequency domain responses. For a beginner, generally, it is difficult to understand and appreciate the step and the frequency responses, particularly the resonance. This paper proposes a student-friendly teaching and learning approach by inculcating the multifaceted versatile software LabVIEWTM along with the educational laboratory virtual instrumentation suite hardware, for studying the RLC circuit time and frequency domain responses. The proposed approach has offered an interactive laboratory experiment where students can model circuits in simulation and hardware circuits on prototype board, and then compare their performances. The theoretical simulations and the obtained experimental data are found to be in very close agreement, thereby enhancing the conviction of students. Finally, the proposed methodology was also subjected to the assessment of learning outcomes based on student feedback, and an average score of 8.05 out of 10 with a standard deviation of 0.471 was received, indicating the overall satisfaction of the students.

  8. Room temperature microwave oscillations in GaN/AlN resonant tunneling diodes with peak current densities up to 220 kA/cm2

    NASA Astrophysics Data System (ADS)

    Encomendero, Jimy; Yan, Rusen; Verma, Amit; Islam, S. M.; Protasenko, Vladimir; Rouvimov, Sergei; Fay, Patrick; Jena, Debdeep; Xing, Huili Grace

    2018-03-01

    We report the generation of room temperature microwave oscillations from GaN/AlN resonant tunneling diodes, which exhibit record-high peak current densities. The tunneling heterostructure grown by molecular beam epitaxy on freestanding GaN substrates comprises a thin GaN quantum well embedded between two AlN tunneling barriers. The room temperature current-voltage characteristics exhibit a record-high maximum peak current density of ˜220 kA/cm2. When biased within the negative differential conductance region, microwave oscillations are measured with a fundamental frequency of ˜0.94 GHz, generating an output power of ˜3.0 μW. Both the fundamental frequency and the output power of the oscillator are limited by the external biasing circuit. Using a small-signal equivalent circuit model, the maximum intrinsic frequency of oscillation for these diodes is predicted to be ˜200 GHz. This work represents a significant step towards microwave power generation enabled by resonant tunneling transport, an ultra-fast process that goes beyond the limitations of current III-Nitride high electron mobility transistors.

  9. Tm-doped fiber laser mode-locking with MoS2-polyvinyl alcohol saturable absorber

    NASA Astrophysics Data System (ADS)

    Cao, Liming; Li, Xing; Zhang, Rui; Wu, Duanduan; Dai, Shixun; Peng, Jian; Weng, Jian; Nie, Qiuhua

    2018-03-01

    We have designed an all-fiber passive mode-locking thulium-doped fiber laser that uses molybdenum disulfide (MoS2) as a saturable absorber (SA) material. A free-standing few-layer MoS2-polyvinyl alcohol (PVA) film is fabricated by liquid phase exfoliation (LPE) and is then transferred onto the end face of a fiber connector. The excellent saturable absorption of the fabricated MoS2-based SA allows the laser to output soliton pulses at a pump power of 500 mW. Fundamental frequency mode-locking is realized at a repetition frequency of 13.9 MHz. The central wavelength is 1926 nm, the 3 dB spectral bandwidth is 2.86 nm and the pulse duration is 1.51 ps. Additionally, third-order harmonic mode-locking of the laser is also achieved. The pulse duration is 1.33 ps, which is slightly narrower than the fundamental frequency mode-locking bandwidth. The experimental results demonstrate that the few-layer MoS2-PVA SA is promising for use in 2 μm laser systems.

  10. A semiconductor nanowire Josephson junction microwave laser

    NASA Astrophysics Data System (ADS)

    Cassidy, Maja; Uilhoorn, Willemijn; Kroll, James; de Jong, Damaz; van Woerkom, David; Nygard, Jesper; Krogstrup, Peter; Kouwenhoven, Leo

    We present measurements of microwave lasing from a single Al/InAs/Al nanowire Josephson junction strongly coupled to a high quality factor superconducting cavity. Application of a DC bias voltage to the Josephson junction results in photon emission into the cavity when the bias voltage is equal to a multiple of the cavity frequency. At large voltage biases, the strong non-linearity of the circuit allows for efficient down conversion of high frequency microwave photons down to multiple photons at the fundamental frequency of the cavity. In this regime, the emission linewidth narrows significantly below the bare cavity linewidth to < 10 kHz and real time analysis of the emission statistics shows above threshold lasing with a power conversion efficiency > 50%. The junction-cavity coupling and laser emission can be tuned rapidly via an external gate, making it suitable to be integrated into a scalable qubit architecture as a versatile source of coherent microwave radiation. This work has been supported by the Netherlands Organisation for Scientific Research (NWO/OCW), Foundation for Fundamental Research on Matter (FOM), European Research Council (ERC), and Microsoft Corporation Station Q.

  11. Aerodynamically and acoustically driven modes of vibration in a physical model of the vocal folds.

    PubMed

    Zhang, Zhaoyan; Neubauer, Juergen; Berry, David A

    2006-11-01

    In a single-layered, isotropic, physical model of the vocal folds, distinct phonation types were identified based on the medial surface dynamics of the vocal fold. For acoustically driven phonation, a single, in-phase, x-10 like eigenmode captured the essential dynamics, and coupled with one of the acoustic resonances of the subglottal tract. Thus, the fundamental frequency appeared to be determined primarily by a subglottal acoustic resonance. In contrast, aerodynamically driven phonation did not naturally appear in the single-layered model, but was facilitated by the introduction of a vertical constraint. For this phonation type, fundamental frequency was relatively independent of the acoustic resonances, and two eigenmodes were required to capture the essential dynamics of the vocal fold, including an out-of-phase x-11 like eigenmode and an in-phase x-10 like eigenmode, as described in earlier theoretical work. The two eigenmodes entrained to the same frequency, and were decoupled from subglottal acoustic resonances. With this independence from the acoustic resonances, vocal fold dynamics appeared to be determined primarily by near-field, fluid-structure interactions.

  12. Peak-picking fundamental period estimation for hearing prostheses.

    PubMed

    Howard, D M

    1989-09-01

    A real-time peak-picking fundamental period estimation device is described which is used in advanced hearing prostheses for the totally and profoundly deafened. The operation of the peak picker is compared with three well-established fundamental frequency estimation techniques: the electrolaryngograph, which is used as a "standard" hardware implementations of the cepstral technique, and the Gold/Rabiner parallel processing algorithm. These comparisons illustrate and highlight some of the important advantages and disadvantages that characterize the operation of these techniques. The special requirements of the hearing prostheses are discussed with respect to the operation of each device, and the choice of the peak picker is found to be felicitous in this application.

  13. Qualitative and quantitative effects of harmonic echocardiographic imaging on endocardial edge definition and side-lobe artifacts

    NASA Technical Reports Server (NTRS)

    Rubin, D. N.; Yazbek, N.; Garcia, M. J.; Stewart, W. J.; Thomas, J. D.

    2000-01-01

    Harmonic imaging is a new ultrasonographic technique that is designed to improve image quality by exploiting the spontaneous generation of higher frequencies as ultrasound propagates through tissue. We studied 51 difficult-to-image patients with blinded side-by-side cineloop evaluation of endocardial border definition by harmonic versus fundamental imaging. In addition, quantitative intensities from cavity versus wall were compared for harmonic versus fundamental imaging. Harmonic imaging improved left ventricular endocardial border delineation over fundamental imaging (superior: harmonic = 71.1%, fundamental = 18.7%; similar: 10.2%; P <.001). Quantitative analysis of 100 wall/cavity combinations demonstrated brighter wall segments and more strikingly darker cavities during harmonic imaging (cavity intensity on a 0 to 255 scale: fundamental = 15.6 +/- 8.6; harmonic = 6.0 +/- 5.3; P <.0001), which led to enhanced contrast between the wall and cavity (1.89 versus 1.19, P <.0001). Harmonic imaging reduces side-lobe artifacts, resulting in a darker cavity and brighter walls, thereby improving image contrast and endocardial delineation.

  14. Harmonic generation with a dual frequency pulse.

    PubMed

    Keravnou, Christina P; Averkiou, Michalakis A

    2014-05-01

    Nonlinear imaging was implemented in commercial ultrasound systems over the last 15 years offering major advantages in many clinical applications. In this work, pulsing schemes coupled with a dual frequency pulse are presented. The pulsing schemes considered were pulse inversion, power modulation, and power modulated pulse inversion. The pulse contains a fundamental frequency f and a specified amount of its second harmonic 2f. The advantages and limitations of this method were evaluated with both acoustic measurements of harmonic generation and theoretical simulations based on the KZK equation. The use of two frequencies in a pulse results in the generation of the sum and difference frequency components in addition to the other harmonic components. While with single frequency pulses, only power modulation and power modulated pulse inversion contained odd harmonic components, with the dual frequency pulse, pulse inversion now also contains odd harmonic components.

  15. Comparative analysis of internal friction and natural frequency measured by free decay and forced vibration.

    PubMed

    Wang, Y Z; Ding, X D; Xiong, X M; Zhang, J X

    2007-10-01

    Relations between various values of the internal friction (tgdelta, Q(-1), Q(-1*), and Lambda/pi) measured by free decay and forced vibration are analyzed systemically based on a fundamental mechanical model in this paper. Additionally, relations between various natural frequencies, such as vibration frequency of free decay omega(FD), displacement-resonant frequency of forced vibration omega(d), and velocity-resonant frequency of forced vibration omega(0) are calculated. Moreover, measurement of natural frequencies of a copper specimen of 99.9% purity has been made to demonstrate the relation between the measured natural frequencies of the system by forced vibration and free decay. These results are of importance for not only more accurate measurement of the elastic modulus of materials but also the data conversion between different internal friction measurements.

  16. Review of image processing fundamentals

    NASA Technical Reports Server (NTRS)

    Billingsley, F. C.

    1985-01-01

    Image processing through convolution, transform coding, spatial frequency alterations, sampling, and interpolation are considered. It is postulated that convolution in one domain (real or frequency) is equivalent to multiplication in the other (frequency or real), and that the relative amplitudes of the Fourier components must be retained to reproduce any waveshape. It is suggested that all digital systems may be considered equivalent, with a frequency content approximately at the Nyquist limit, and with a Gaussian frequency response. An optimized cubic version of the interpolation continuum image is derived as a set of cubic spines. Pixel replication has been employed to enlarge the visable area of digital samples, however, suitable elimination of the extraneous high frequencies involved in the visable edges, by defocusing, is necessary to allow the underlying object represented by the data values to be seen.

  17. Diode-end-pumped continuously tunable single frequency Tm, Ho:LLF laser at 2.06 μm.

    PubMed

    Zhang, Xinlu; Zhang, Su; Xiao, Nana; Cui, Jinhui; Zhao, Jiaqun; Li, Li

    2014-03-10

    We report on a laser diode-end-pumped continuously tunable single frequency Tm, Ho:LLF laser near room temperature. For transmission of 5%, the maximum single frequency output power of 221 mW at 2064.4 nm was obtained by using two uncoated etalons. The single frequency Tm, Ho:LLF laser operated on the fundamental transverse mode with an M2 factor of 1.13, and the output frequency could be tuned continuously near 1.5 GHz by angle tuning only of the 1 mm thick etalon. Furthermore, the influence of output coupler transmission on the laser performance was also investigated. The single frequency laser can be used as a seed laser for coherent Doppler lidar and differential absorption lidar systems.

  18. Spectroscopy of antiprotonic helium atoms and its contribution to the fundamental physical constants

    PubMed Central

    Hayano, Ryugo S.

    2010-01-01

    Antiprotonic helium atom, a metastable neutral system consisting of an antiproton, an electron and a helium nucleus, was serendipitously discovered, and has been studied at CERN’s antiproton decelerator facility. Its transition frequencies have recently been measured to nine digits of precision by laser spectroscopy. By comparing these experimental results with three-body QED calculations, the antiproton-to-electron massratio was determined as 1836.152674(5). This result contributed to the CODATA recommended values of the fundamental physical constants. PMID:20075605

  19. Mechanical spectroscopy of nanocrystalline aluminum films: effects of frequency and grain size on internal friction.

    PubMed

    Sosale, Guruprasad; Almecija, Dorothée; Das, Kaushik; Vengallatore, Srikar

    2012-04-20

    Energy dissipation by internal friction is a property of fundamental interest for probing the effects of scale on mechanical behavior in nanocrystalline metallic films and for guiding the use of these materials in the design of high-Q micro/nanomechanical resonators. This paper describes an experimental study to measure the effects of frequency, annealing and grain size on internal friction at room temperature in sputter-deposited nanocrystalline aluminum films with thicknesses ranging from 60 to 120 nm. Internal friction was measured using a single-crystal silicon microcantilever platform that calibrates dissipation against the fundamental limits of thermoelastic damping. Internal friction was a weak function of frequency, reducing only by a factor of two over three decades of frequency (70 Hz to 44 kHz). Annealing led to significant grain growth and the average grain size of 100 nm thick films increased from 90 to 390 nm after annealing for 1 h at 450 (∘)C. This increase in grain size was accompanied by a decrease in internal friction from 0.05 to 0.02. Taken together, these results suggest that grain-boundary sliding, characterized by a spectrum of relaxation times, contributes to internal friction in these films. © 2012 IOP Publishing Ltd

  20. Generation mechanism of nonlinear ultrasonic Lamb waves in thin plates with randomly distributed micro-cracks.

    PubMed

    Zhao, Youxuan; Li, Feilong; Cao, Peng; Liu, Yaolu; Zhang, Jianyu; Fu, Shaoyun; Zhang, Jun; Hu, Ning

    2017-08-01

    Since the identification of micro-cracks in engineering materials is very valuable in understanding the initial and slight changes in mechanical properties of materials under complex working environments, numerical simulations on the propagation of the low frequency S 0 Lamb wave in thin plates with randomly distributed micro-cracks were performed to study the behavior of nonlinear Lamb waves. The results showed that while the influence of the randomly distributed micro-cracks on the phase velocity of the low frequency S 0 fundamental waves could be neglected, significant ultrasonic nonlinear effects caused by the randomly distributed micro-cracks was discovered, which mainly presented as a second harmonic generation. By using a Monte Carlo simulation method, we found that the acoustic nonlinear parameter increased linearly with the micro-crack density and the size of micro-crack zone, and it was also related to the excitation frequency and friction coefficient of the micro-crack surfaces. In addition, it was found that the nonlinear effect of waves reflected by the micro-cracks was more noticeable than that of the transmitted waves. This study theoretically reveals that the low frequency S 0 mode of Lamb waves can be used as the fundamental waves to quantitatively identify micro-cracks in thin plates. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Fundamental voice frequence during normal and abnormal growth, and after androgen treatment.

    PubMed Central

    Vuorenkoski, V; Lenko, H L; Tjernlund, P; Vuorenkoski, L; Perheentupa, J

    1978-01-01

    A simple treatment was shown to be suitable for clinical measurement of fundamental voice frequency. Basal frequency (SFF) and lowest frequency (LF) were determined in 374 normal subjects aged 6 years to adulthood. SFF fell between ages 8 and 10 years in boys (from 259 to 247 Hz), but not in girls (253 Hz). LF fell between ages 6 and 10 years in boys (from 234 to 203 Hz) and girls (from 230 to 218 Hz), and a sex difference appeared. In puberty, parallel to pubic hair (PH) development, a gradual fall of SFF and LF occurred in both boys (to 100 and 90 Hz, respectively) and girls (to 213 and 180 Hz). As a group, young hypopituitary children and girls with Turner's syndrome had a high SFF, and prepubertal boys with delayed maturation a low SFF. In some children with prenatal growth failure, SFF was abnormally high. The girls with Turner's syndrome exhibited a high, though individually variable, sensitivity of voice to androgen; their voices became lower before the appearance of any other masculinising effects. The instrument is useful for characterisation of growth failure syndromes and stages of puberty. It is particularly recommended for monitoring an undesirable effect on the voice during androgen treatment. Images Fig. 1 p202-b PMID:646429

  2. A comparison of harmonic production in trained and untrained singers

    NASA Astrophysics Data System (ADS)

    Hildebrand, Jonathan H.; Caso, Hilary J.

    2004-05-01

    This study was designed to investigate the differences in the tone qualities of trained and untrained singers of both genders by measuring the ratio of energy found in the fundamental frequency to that found in the harmonics of the two groups. Forty trained and untrained male and female subjects (ten in each group) sang the vowels [a e i o u] in the words ``me cake father obey too.'' Each subject sang through the list of words in its entirety one time. They were also asked to produce each word at a constant pitch of their choosing. The intensity (dB) was then measured at the vowel midpoint in the intact vowel, and then again with the fundamental filtered out. These two measurements allowed for a comparison to be made by subtracting the results. This process produced results showing that the fundamental frequency was responsible for the majority of the trained singers', vocal productions, where harmonics were responsible for the majority of the untrained singers', vocal productions. The data also showed that these results were more prominent for the production of the high vowels in both genders, and for women overall.

  3. Quasi-phase-matching of the dual-band nonlinear left-handed metamaterial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Yahong, E-mail: yhliu@nwpu.edu.cn; Song, Kun; Gu, Shuai

    2014-11-17

    We demonstrate a type of nonlinear meta-atom creating a dual-band nonlinear left-handed metamaterial (DNLHM). The DNLHM operates at two distinct left-handed frequency bands where there is an interval of one octave between the two center frequencies. Under the illumination of a high-power signal at the first left-handed frequency band corresponding to fundamental frequency (FF), second-harmonic generation (SHG) is observed at the second left-handed band. This means that our DNLHM supports backward-propagating waves both at FF and second-harmonic (SH) frequency. We also experimentally demonstrate quasi-phase-matching configurations for the backward SHG. This fancy parametric process can significantly transmits the SH generated bymore » an incident FF wave.« less

  4. Size-dependent resonance frequencies of cantilevered and bridged nanosensors

    NASA Astrophysics Data System (ADS)

    Shi, W.; Zou, J.; Lee, K. Y.; Li, X. F.

    2018-03-01

    This paper studies transverse vibration of nanoscale cantilevered and bridged sensors carrying a nanoparticle. The nanoscale sensors are modelled as Euler-Bernoulli beams with surface effect and nanoparticle as a concentrated mass. Frequency equations of cantilevered and bridged beam-mass system are derived and exact resonance frequencies are calculated. An alternative Fredholm integral equation method is used to obtain an approximate explicit expression for the fundamental frequency for both cases. A comparison between the approximate and analytical results is made and the approximation accuracy is satisfactory. The influences of the residual surface stress, surface elasticity, and attached mass on the resonance frequencies and mode shapes are discussed. These results are useful to illustrate the surface phenomena and are helpful to design micro-/nano-mechanical sensors.

  5. The Superconducting Cavity Stabilized Oscillator

    NASA Technical Reports Server (NTRS)

    Turneaure, J. P.; Buchman, Saps; Lipa, John

    1997-01-01

    Superconducting Cavity Stabilized Oscillators (SCSOs) have produced the most stable clocks to date for integration times between 10(exp 2) and 10(exp 3) seconds, achieving a fractional frequency stability of 2 x 10(exp -16) for a sampling time of 100 s. The principal contributors to cavity frequency variations are: (1) acceleration effects due to gravity and vibrations; (2) temperature variations; (3) variations in the energy stored in the cavity; and (4) noise introduced by the frequency stabilization circuit. We discuss the prospects for improvements in all these areas for both ground-based and space-based SCSOs, which may lead to SCSOs with fractional frequency stabilities below 10(exp -17). SCSOs of this frequency stability will be useful for testing fundamental physical principles.

  6. Effect of Context on the Contribution of Individual Harmonics to Residue Pitch.

    PubMed

    Gockel, Hedwig E; Alsindi, Sami; Hardy, Charles; Carlyon, Robert P

    2017-12-01

    There is evidence that the contribution of a given harmonic in a complex tone to residue pitch is influenced by the accuracy with which the frequency of that harmonic is encoded. The present study investigated whether listeners adjust the weights assigned to individual harmonics based on acquired knowledge of the reliability of the frequency estimates of those harmonics. In a two-interval forced-choice task, seven listeners indicated which of two 12-harmonic complex tones had the higher overall pitch. In context trials (60 % of all trials), the fundamental frequency (F0) was 200 Hz in one interval and 200 + ΔF0 Hz in the other. In different (blocked) conditions, either the 3rd or the 4th harmonic (plus the 7th, 9th, and 12th harmonics), were replaced by narrowband noises that were identical in the two intervals. Feedback was provided. In randomly interspersed test trials (40 % of all trials), the fundamental frequency was 200 + ΔF0/2 Hz in both intervals; in the second interval, either the third or the fourth harmonic was shifted slightly up or down in frequency with equal probability. There were no narrowband noises. Feedback was not provided. The results showed that substitution of a harmonic by noise in context trials reduced the contribution of that harmonic to pitch judgements in the test trials by a small but significant amount. This is consistent with the notion that listeners give smaller weight to a harmonic or frequency region when they have learned that this frequency region does not provide reliable information for a given task.

  7. Filter bank canonical correlation analysis for implementing a high-speed SSVEP-based brain-computer interface

    NASA Astrophysics Data System (ADS)

    Chen, Xiaogang; Wang, Yijun; Gao, Shangkai; Jung, Tzyy-Ping; Gao, Xiaorong

    2015-08-01

    Objective. Recently, canonical correlation analysis (CCA) has been widely used in steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs) due to its high efficiency, robustness, and simple implementation. However, a method with which to make use of harmonic SSVEP components to enhance the CCA-based frequency detection has not been well established. Approach. This study proposed a filter bank canonical correlation analysis (FBCCA) method to incorporate fundamental and harmonic frequency components to improve the detection of SSVEPs. A 40-target BCI speller based on frequency coding (frequency range: 8-15.8 Hz, frequency interval: 0.2 Hz) was used for performance evaluation. To optimize the filter bank design, three methods (M1: sub-bands with equally spaced bandwidths; M2: sub-bands corresponding to individual harmonic frequency bands; M3: sub-bands covering multiple harmonic frequency bands) were proposed for comparison. Classification accuracy and information transfer rate (ITR) of the three FBCCA methods and the standard CCA method were estimated using an offline dataset from 12 subjects. Furthermore, an online BCI speller adopting the optimal FBCCA method was tested with a group of 10 subjects. Main results. The FBCCA methods significantly outperformed the standard CCA method. The method M3 achieved the highest classification performance. At a spelling rate of ˜33.3 characters/min, the online BCI speller obtained an average ITR of 151.18 ± 20.34 bits min-1. Significance. By incorporating the fundamental and harmonic SSVEP components in target identification, the proposed FBCCA method significantly improves the performance of the SSVEP-based BCI, and thereby facilitates its practical applications such as high-speed spelling.

  8. Harmonic Hopping, and Both Punctuated and Gradual Evolution of Acoustic Characters in Selasphorus Hummingbird Tail-Feathers

    PubMed Central

    Clark, Christopher James

    2014-01-01

    Models of character evolution often assume a single mode of evolutionary change, such as continuous, or discrete. Here I provide an example in which a character exhibits both types of change. Hummingbirds in the genus Selasphorus produce sound with fluttering tail-feathers during courtship. The ancestral character state within Selasphorus is production of sound with an inner tail-feather, R2, in which the sound usually evolves gradually. Calliope and Allen's Hummingbirds have evolved autapomorphic acoustic mechanisms that involve feather-feather interactions. I develop a source-filter model of these interactions. The ‘source’ comprises feather(s) that are both necessary and sufficient for sound production, and are aerodynamically coupled to neighboring feathers, which act as filters. Filters are unnecessary or insufficient for sound production, but may evolve to become sources. Allen's Hummingbird has evolved to produce sound with two sources, one with feather R3, another frequency-modulated sound with R4, and their interaction frequencies. Allen's R2 retains the ancestral character state, a ∼1 kHz “ghost” fundamental frequency masked by R3, which is revealed when R3 is experimentally removed. In the ancestor to Allen's Hummingbird, the dominant frequency has ‘hopped’ to the second harmonic without passing through intermediate frequencies. This demonstrates that although the fundamental frequency of a communication sound may usually evolve gradually, occasional jumps from one character state to another can occur in a discrete fashion. Accordingly, mapping acoustic characters on a phylogeny may produce misleading results if the physical mechanism of production is not known. PMID:24722049

  9. Peculiar double-periodic pulsation in RR Lyrae stars of the OGLE collection - II. Short-period stars with a dominant radial fundamental mode

    NASA Astrophysics Data System (ADS)

    Prudil, Z.; Smolec, R.; Skarka, M.; Netzel, H.

    2017-03-01

    We report the discovery of a new group of double-periodic stars in the OGLE Galactic bulge photometry. In 38 stars identified as fundamental-mode RR Lyrae and four classified as first-overtone RR Lyrae, we detected an additional shorter periodicity. The periods of the dominant variability in the newly discovered group are 0.28 < PD < 0.41 d. Period ratios (0.68-0.72) are smaller than the period ratios of the Galactic bulge RRd stars. The typical amplitude ratio (of the additional to the dominant periodicity) is 20 per cent for the stars identified as fundamental-mode RR Lyrae and 50 per cent for stars classified as first-overtone RR Lyrae. 10 stars from our sample exhibit equidistant peaks in the frequency spectrum, which suggests the Blazhko-type modulation of the main pulsation frequency and/or additional periodicity. The Fourier coefficients R21 and R31 are some of the lowest among fundamental-mode RR Lyrae stars, but among the highest for the first-overtone pulsators. For the phase Fourier coefficients φ21 and φ31, our stars lie between RRab and RRc stars. The stars discussed were compared with radial linear pulsation models. Their position in the Petersen diagram cannot be reproduced by assuming that two radial modes are excited and their physical parameters are like those characteristic of RR Lyrae stars. The non-radial-mode scenario also faces difficulties. We conclude that the dominant variability is most likely due to pulsation in the radial fundamental mode, which applies to stars classified as first-overtone mode pulsators. At this point, we cannot explain the nature of the additional periodicity. Even more, the classification of the stars as RR Lyrae should be treated as tentative.

  10. Secondary instability in boundary-layer flows

    NASA Technical Reports Server (NTRS)

    Nayfeh, A. H.; Bozatli, A. N.

    1979-01-01

    The stability of a secondary Tollmien-Schlichting wave, whose wavenumber and frequency are nearly one half those of a fundamental Tollmien-Schlichting instability wave is analyzed using the method of multiple scales. Under these conditions, the fundamental wave acts as a parametric exciter for the secondary wave. The results show that the amplitude of the fundamental wave must exceed a critical value to trigger this parametric instability. This value is proportional to a detuning parameter which is the real part of k - 2K, where k and K are the wavenumbers of the fundamental and its subharmonic, respectively. For Blasius flow, the critical amplitude is approximately 29% of the mean flow, and hence many other secondary instabilities take place before this parametric instability becomes significant. For other flows where the detuning parameter is small, such as free-shear layer flows, the critical amplitude can be small, thus the parametric instability might play a greater role.

  11. Spatiotemporal frequency characteristics of cerebral oscillations during the perception of fundamental frequency contour changes in one-syllable intonation.

    PubMed

    Ueno, Sanae; Okumura, Eiichi; Remijn, Gerard B; Yoshimura, Yuko; Kikuchi, Mitsuru; Shitamichi, Kiyomi; Nagao, Kikuko; Mochiduki, Masayuki; Haruta, Yasuhiro; Hayashi, Norio; Munesue, Toshio; Tsubokawa, Tsunehisa; Oi, Manabu; Nakatani, Hideo; Higashida, Haruhiro; Minabe, Yoshio

    2012-05-02

    Accurate perception of fundamental frequency (F0) contour changes in the human voice is important for understanding a speaker's intonation, and consequently also his/her attitude. In this study, we investigated the neural processes involved in the perception of F0 contour changes in the Japanese one-syllable interjection "ne" in 21 native-Japanese listeners. A passive oddball paradigm was applied in which "ne" with a high falling F0 contour, used when urging a reaction from the listener, was randomly presented as a rare deviant among a frequent "ne" syllable with a flat F0 contour (i.e., meaningless intonation). We applied an adaptive spatial filtering method to the neuromagnetic time course recorded by whole-head magnetoencephalography (MEG) and estimated the spatiotemporal frequency dynamics of event-related cerebral oscillatory changes in the oddball paradigm. Our results demonstrated a significant elevation of beta band event-related desynchronization (ERD) in the right temporal and frontal areas, in time windows from 100 to 300 and from 300 to 500 ms after the onset of deviant stimuli (high falling F0 contour). This is the first study to reveal detailed spatiotemporal frequency characteristics of cerebral oscillations during the perception of intonational (not lexical) F0 contour changes in the human voice. The results further confirmed that the right hemisphere is associated with perception of intonational F0 contour information in the human voice, especially in early time windows. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. A HYBRID MODE MODEL OF THE BLAZHKO EFFECT, SHOWN TO ACCURATELY FIT KEPLER DATA FOR RR Lyr

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryant, Paul H., E-mail: pbryant@ucsd.edu

    2014-03-01

    The waveform for Blazhko stars can be substantially different during the ascending and descending parts of the Blazhko cycle. A hybrid model, consisting of two component oscillators of the same frequency, is proposed as a means to fit the data over the entire cycle. One component exhibits a sawtooth-like velocity waveform while the other is nearly sinusoidal. One method of generating such a hybrid is presented: a nonlinear model is developed for the first overtone mode, which, if excited to large amplitude, is found to drop strongly in frequency and become highly non-sinusoidal. If the frequency drops sufficiently to becomemore » equal to the fundamental frequency, the two can become phase locked and form the desired hybrid. A relationship is assumed between the hybrid mode velocity and the observed light curve, which is approximated as a power series. An accurate fit of the hybrid model is made to actual Kepler data for RR Lyr. The sinusoidal component may tend to stabilize the period of the hybrid which is found in real Blazhko data to be extremely stable. It is proposed that the variations in amplitude and phase might result from a nonlinear interaction with a third mode, possibly a nonradial mode at 3/2 the fundamental frequency. The hybrid model also applies to non-Blazhko RRab stars and provides an explanation for the light curve bump. A method to estimate the surface gravity is also proposed.« less

  13. Speaking fundamental frequency and vowel formant frequencies: effects on perception of gender.

    PubMed

    Gelfer, Marylou Pausewang; Bennett, Quinn E

    2013-09-01

    The purpose of the present study was to investigate the contribution of vowel formant frequencies to gender identification in connected speech, the distinctiveness of vowel formants in males versus females, and how ambiguous speaking fundamental frequencies (SFFs) and vowel formants might affect perception of gender. Multivalent experimental. Speakers subjects (eight tall males, eight short females, and seven males and seven females of "middle" height) were recorded saying two carrier phrases to elicit the vowels /i/ and /α/ and a sentence. The gender/height groups were selected to (presumably) maximize formant differences between some groups (tall vs short) and minimize differences between others (middle height). Each subjects' samples were digitally altered to distinct SFFs (116, 145, 155, 165, and 207 Hz) to represent SFFs typical of average males, average females, and in an ambiguous range. Listeners judged the gender of each randomized altered speech sample. Results indicated that female speakers were perceived as female even with an SFF in the typical male range. For male speakers, gender perception was less accurate at SFFs of 165 Hz and higher. Although the ranges of vowel formants had considerable overlap between genders, significant differences in formant frequencies of males and females were seen. Vowel formants appeared to be important to perception of gender, especially for SFFs in the range of 145-165 Hz; however, formants may be a more salient cue in connected speech when compared with isolated vowels or syllables. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  14. Function and Evolution of Vibrato-like Frequency Modulation in Mammals.

    PubMed

    Charlton, Benjamin D; Taylor, Anna M; Reby, David

    2017-09-11

    Why do distantly related mammals like sheep, giant pandas, and fur seals produce bleats that are characterized by vibrato-like fundamental frequency (F0) modulation? To answer this question, we used psychoacoustic tests and comparative analyses to investigate whether this distinctive vocal feature has evolved to improve the perception of formants, key acoustic components of animal calls that encode important information about the caller's size and identity [1]. Psychoacoustic tests on humans confirmed that vibrato-like F0 modulation improves the ability of listeners to detect differences in the formant patterns of synthetic bleat-like stimuli. Subsequent phylogenetically controlled comparative analyses revealed that vibrato-like F0 modulation has evolved independently in six mammalian orders in vocal signals with relatively high F0 and, therefore, low spectral density (i.e., less harmonic overtones). We also found that mammals modulate the vibrato in these calls over greater frequency extents when the number of harmonic overtones per formant is low, suggesting that this is a mechanism to improve formant perception in calls with low spectral density. Our findings constitute the first evidence that formant perception in non-speech sounds is improved by fundamental frequency modulation and provide a mechanism for the convergent evolution of bleat-like calls in mammals. They also indicate that selection pressures for animals to transmit important information encoded by formant frequencies (on size and identity, for example) are likely to have been a key driver in the evolution of mammal vocal diversity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Electromagnetic Resonance of Astigmatic Gaussian Beam to the High Frequency Gravitational Waves

    NASA Astrophysics Data System (ADS)

    Zhong, Yuan-Hong; Li, Jin; Zhou, Yao; Lei, Qi-Lun

    2016-10-01

    Not Available Supported by the National Natural Science Foundation of China under Grant Nos 11205254 and 61501069, and the Fundamental Research Funds for the Central Universities under Grant No 106112016CDJXY300002.

  16. Postharvest Fumigation Research at ARS

    USDA-ARS?s Scientific Manuscript database

    Agricultural industries are facing, with increasing frequency, environmental and pest-related food safety requirements that are fundamentally difficult to balance. Failure to disinfest foodstuffs in trade and marketing channels can result in insect- and microbial-derived damage which limits economic...

  17. Development of indirect EFBEM for radiating noise analysis including underwater problems

    NASA Astrophysics Data System (ADS)

    Kwon, Hyun-Wung; Hong, Suk-Yoon; Song, Jee-Hun

    2013-09-01

    For the analysis of radiating noise problems in medium-to-high frequency ranges, the Energy Flow Boundary Element Method (EFBEM) was developed. EFBEM is the analysis technique that applies the Boundary Element Method (BEM) to Energy Flow Analysis (EFA). The fundamental solutions representing spherical wave property for radiating noise problems in open field and considering the free surface effect in underwater are developed. Also the directivity factor is developed to express wave's directivity patterns in medium-to-high frequency ranges. Indirect EFBEM by using fundamental solutions and fictitious source was applied to open field and underwater noise problems successfully. Through numerical applications, the acoustic energy density distributions due to vibration of a simple plate model and a sphere model were compared with those of commercial code, and the comparison showed good agreement in the level and pattern of the energy density distributions.

  18. Simultaneous negative refraction and focusing of fundamental frequency and second-harmonic fields by two-dimensional photonic crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jun; College of Physics and Electronic Engineering, Henan Normal University, 453007 Xinxiang, Henan; Zhang, Xiangdong, E-mail: zhangxd@bit.edu.cn

    2015-09-28

    Simultaneous negative refraction for both the fundamental frequency (FF) and second-harmonic (SH) fields in two-dimensional nonlinear photonic crystals have been found through both the physical analysis and exact numerical simulation. By combining such a property with the phase-matching condition and strong second-order susceptibility, we have designed a SH lens to realize focusing for both the FF and SH fields at the same time. Good-quality non-near field images for both FF and SH fields have been observed. The physical mechanism for such SH focusing phenomena has been disclosed, which is different from the backward SH generation as has been pointed outmore » in the previous investigations. In addition, the effect of absorption losses on the phenomena has also been discussed. Thus, potential applications of these phenomena to biphotonic microscopy technique are anticipated.« less

  19. Harmonic surface acoustic waves on gallium nitride thin films.

    PubMed

    Justice, Joshua; Lee, Kyoungnae; Korakakis, D

    2012-08-01

    SAW devices operating at the fundamental frequency and the 5th, 7th, 9th, and 11th harmonics have been designed, fabricated, and measured. Devices were fabricated on GaN thin films on sapphire substrates, which were grown via metal organic vapor phase epitaxy (MOVPE). Operating frequencies of 230, 962, 1338, 1720, and 2100 MHz were achieved with devices that had a fundamental wavelength, lambda0 = 20 μm. Gigahertz operation is realized with relatively large interdigital transducers that do not require complicated submicrometer fabrication techniques. SAW devices fabricated on the GaN/sapphire bilayer have an anisotropic propagation when the wavelength is longer than the GaN film thickness. It is shown that for GaN thin films, where kh(GaN) > 10 (k = 2pi/lambda and h(GaN) = GaN film thickness), effects of the substrate on the SAW propagation are eliminated. Bulk mode suppression at harmonic operation is also demonstrated.

  20. Biomechanics of fundamental frequency regulation: Constitutive modeling of the vocal fold lamina propria.

    PubMed

    Chan, Roger W; Siegmund, Thomas; Zhang, Kai

    2009-12-01

    Accurate characterization of biomechanical characteristics of the vocal fold is critical for understanding the regulation of vocal fundamental frequency (F(0)), which depends on the active control of the intrinsic laryngeal muscles as well as the passive biomechanical response of the vocal fold lamina propria. Specifically, the tissue stress-strain response and viscoelastic properties under cyclic tensile deformation are relevant, when the vocal folds are subjected to length and tension changes due to posturing. This paper describes a constitutive modeling approach quantifying the relationship between vocal fold stress and strain (or stretch), and establishes predictions of F(0) with the string model of phonation based on the constitutive parameters. Results indicated that transient and time-dependent changes in F(0), including global declinations in declarative sentences, as well as local F(0) overshoots and undershoots, can be partially attributed to the time-dependent viscoplastic response of the vocal fold cover.

  1. High-Resolution Fourier Transform Infrared Spectrum of the ν 12 Fundamental Band of Ethylene (C 2H 4)

    NASA Astrophysics Data System (ADS)

    Tan, T. L.; Lau, S. Y.; Ong, P. P.; Goh, K. L.; Teo, H. H.

    2000-10-01

    The infrared spectrum of the ν12 fundamental band of ethylene (C2H4) has been measured with an unapodized resolution of 0.004 cm-1 in the frequency range of 1380-1500 cm-1 using the Fourier transform technique. By assigning and fitting a total of 1387 infrared transitions using a Watson's A-reduced Hamiltonian in the Ir representation, rovibrational constants for the upper state (v12 = 1) up to five quartic and three sextic centrifugal distortions terms were derived. They represent the most accurate constants for the band so far. The rms deviation of the fit was 0.00033 cm-1. The A-type ν12 band with a band center at 1442.44299 ± 0.00003 cm-1 was found to be relatively free from local frequency perturbations. The inertial defect Δ12 was found to be 0.24201 ± 0.00002 u Å2.

  2. Relative fundamental frequency during vocal onset and offset in older speakers with and without Parkinson's disease.

    PubMed

    Stepp, Cara E

    2013-03-01

    The relative fundamental frequency (RFF) surrounding production of a voiceless consonant has previously been shown to be lower in speakers with hypokinetic dysarthria and Parkinson's disease (PD) relative to age/sex matched controls. Here RFF was calculated in 32 speakers with PD without overt hypokinetic dysarthria and 32 age and sex matched controls to better understand the relationships between RFF and PD progression, medication status, and sex. Results showed that RFF was statistically significantly lower in individuals with PD compared with healthy age-matched controls and was statistically significantly lower in individuals diagnosed at least 5 yrs prior to experimentation relative to individuals recorded less than 5 yrs past diagnosis. Contrary to previous trends, no effect of medication was found. However, a statistically significant effect of sex on offset RFF was shown, with lower values in males relative to females. Future work examining the physiological bases of RFF is warranted.

  3. Titanium-doped sapphire laser research and design study

    NASA Technical Reports Server (NTRS)

    Moulton, Peter F.

    1987-01-01

    Three main topics were considered in this study: the fundamental laser parameters of titanium-doped sapphire, characterization of commercially grown material, and design of a tunable, narrow-linewidth laser. Fundamental parameters investigated included the gain cross section, upper-state lifetime as a function of temperature and the surface-damage threshold. Commercial material was found to vary widely in the level of absorption of the laser wavelength with the highest absorption in Czochralski-grown crystals. Several Yi:sapphire lasers were constructed, including a multimode laser with greater than 50mJ of output energy and a single-transverse-mode ring laser, whose spectral and temporal characteristics were completely characterized. A design for a narrow-linewidth (single-frequency) Ti:sapphire laser was developed, based on the results of the experimental work. The design involves the use of a single-frequency, quasi-cw master oscillator, employed as an injection source for a pulsed ring laser.

  4. Optical Atomic Clock for Fundamental Physics and Precision Metrology in Space

    NASA Astrophysics Data System (ADS)

    Williams, Jason; Le, Thanh; Kulas, Sascha; Yu, Nan

    2017-04-01

    The maturity of optical atomic clocks (OC), which operate at optical frequencies for higher quality-factor as compared to their microwave counterparts, has rapidly progressed to the point where lab-based systems now outperform the record cesium clocks by orders of magnitude in both accuracy and stability. We will present our efforts to develop a strontium optical clock testbed at JPL, aimed towards extending the exceptional performance demonstrated by OCs from state-of-the-art laboratory designs to a transportable instrument that can fit within the space and power constraints of e.g. a single express rack onboard the International Space Station. The overall technology will find applications for future fundamental physics research, both on ground and in space, precision time keeping, and NASA/JPL time and frequency test capabilities. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration.

  5. Fundamentals of bipolar high-frequency surgery.

    PubMed

    Reidenbach, H D

    1993-04-01

    In endoscopic surgery a very precise surgical dissection technique and an efficient hemostasis are of decisive importance. The bipolar technique may be regarded as a method which satisfies both requirements, especially regarding a high safety standard in application. In this context the biophysical and technical fundamentals of this method, which have been known in principle for a long time, are described with regard to the special demands of a newly developed field of modern surgery. After classification of this method into a general and a quasi-bipolar mode, various technological solutions of specific bipolar probes, in a strict and in a generalized sense, are characterized in terms of indication. Experimental results obtained with different bipolar instruments and probes are given. The application of modern microprocessor-controlled high-frequency surgery equipment and, wherever necessary, the integration of additional ancillary technology into the specialized bipolar instruments may result in most useful and efficient tools of a key technology in endoscopic surgery.

  6. Broadband pulsed difference frequency generation laser source centered 3326 nm based on ring fiber lasers

    NASA Astrophysics Data System (ADS)

    Chen, Guangwei; Li, Wenlei

    2018-03-01

    A broadband pulsed mid-infrared difference frequency generation (DFG) laser source based on MgO-doped congruent LiNbO3 bulk is experimentally demonstrated, which employs a homemade pulsed ytterbium-doped ring fiber laser and a continuous wave erbium-doped ring fiber laser to act as seed sources. The experimental results indicate that the perfect phase match crystal temperature is about 74.5∘C. The maximum spectrum bandwidth of idler is about 60 nm with suitable polarization states of fundamental lights. The central wavelength of idlers varies from 3293 nm to 3333 nm over the crystal temperature ranges of 70.4-76∘C. A jump of central wavelength exists around crystal temperature of 72∘C with variation of about 30 nm. The conversion efficiency of DFG can be tuned with the crystal temperature and polarization states of fundamental lights.

  7. Third harmonic frequency generation by type-I critically phase-matched LiB3O5 crystal by means of optically active quartz crystal.

    PubMed

    Gapontsev, Valentin P; Tyrtyshnyy, Valentin A; Vershinin, Oleg I; Davydov, Boris L; Oulianov, Dmitri A

    2013-02-11

    We present a method of third harmonic generation at 355 nm by frequency mixing of fundamental and second harmonic radiation of an ytterbium nanosecond pulsed all-fiber laser in a type-I phase-matched LiB(3)O(5) (LBO) crystal where originally orthogonal polarization planes of the fundamental and second harmonic beams are aligned by an optically active quartz crystal. 8 W of ultraviolet light at 355 nm were achieved with 40% conversion efficiency from 1064 nm radiation. The conversion efficiency obtained in a type-I phase-matched LBO THG crystal was 1.6 times higher than the one achieved in a type-II LBO crystal at similar experimental conditions. In comparison to half-wave plates traditionally used for polarization alignment the optically active quartz crystal has much lower temperature dependence and requires simpler optical alignment.

  8. 80-W green KTP laser used in photoselective laser vaporization of the prostrate by frequency doubling of Yb 3+ -doped large-mode area fiber laser

    NASA Astrophysics Data System (ADS)

    Xia, Hongxing; Li, Zhengjia

    2007-05-01

    Photoselective laser vaporization of the prostate (PVP) is the most promising method for the treatment of benign prostatic hyperplasia (BPH), but KTP lasers used in PVP with lamp-pumped are low efficient .To increase the efficiency , we develop a 80-W, 400kHz, linearly polarized green laser based on a frequency-doubled fiber laser. A polarization-maintaining large-mode area (LMA) fiber amplifier generate polarized 1064nm fundamental wave by amplifying the seed signal from a composite Cr 4+:YAG-Nd 3+:YAG crystal fiber laser. The fundamental wave is injected into a KTP crystal with confined temperature management to achieve second harmonic generation (SHG). The overall electrical efficiency to the green portion of the spectrum is 10%.80-W maintenance-free long-lifetime KTP laser obtained can well satisfy the need of PVP.

  9. Rainfall: State of the Science

    NASA Astrophysics Data System (ADS)

    Testik, Firat Y.; Gebremichael, Mekonnen

    Rainfall: State of the Science offers the most up-to-date knowledge on the fundamental and practical aspects of rainfall. Each chapter, self-contained and written by prominent scientists in their respective fields, provides three forms of information: fundamental principles, detailed overview of current knowledge and description of existing methods, and emerging techniques and future research directions. The book discusses • Rainfall microphysics: raindrop morphodynamics, interactions, size distribution, and evolution • Rainfall measurement and estimation: ground-based direct measurement (disdrometer and rain gauge), weather radar rainfall estimation, polarimetric radar rainfall estimation, and satellite rainfall estimation • Statistical analyses: intensity-duration-frequency curves, frequency analysis of extreme events, spatial analyses, simulation and disaggregation, ensemble approach for radar rainfall uncertainty, and uncertainty analysis of satellite rainfall products The book is tailored to be an indispensable reference for researchers, practitioners, and graduate students who study any aspect of rainfall or utilize rainfall information in various science and engineering disciplines.

  10. Aeroelastic Stability of Modern Bearingless Rotors: A Parametric Investigation

    NASA Technical Reports Server (NTRS)

    Nguyen, Khanh Q.

    1994-01-01

    The University of Maryland Advanced Rotorcraft Code (UMARC) is utilized to study the effects of blade design parameters on the aeroelastic stability of an isolated modern bearingless rotor blade in hover. The McDonnell Douglas Advanced Rotor Technology (MDART) Rotor is the baseline rotor investigated. Results indicate that kinematic pitch-lag coupling introduced through the control system geometry and the damping levels of the shear lag dampers strongly affect the hover inplane damping of the baseline rotor blade. Hub precone, pitchcase chordwise stiffness, and blade fundamental torsion frequency have small to moderate influence on the inplane damping, while blade pre-twist and placements of blade fundamental flapwise and chord-wise frequencies have negligible effects. A damperless configuration with a leading edge pitch-link, 15 deg of pitch-link cant angle, and reduced pitch-link stiffness is shown to be stable with an inplane damping level in excess of 2.7 percent critical at the full hover tip speed.

  11. The Stability of Periodic Orbits.

    DTIC Science & Technology

    1981-01-21

    first class, the new stable orbit has a fundamental frequency equal to half that of the original orbit. Thesebifurcations (for which one real...eigenvalue of the Poincare map passes out through the unit circle at -1 : see Appendix 1) 9,10 are observed and are referred to as subharmonic or period...doubling bifurcations. At such a bifurcation componenns of x(t) with a frequency -8- equal to half that of the original longitudinal motion grow

  12. Investigation of Molecule-Surface Interactions With Overtone Absorption Spectroscopy and Computational Methods

    DTIC Science & Technology

    2010-11-01

    method at a fraction of the computational cost . The overtone frequency serves as the bridge between the molecule-surface interaction model and...the computational cost of utilizing higher levels of theory such as MP2. The second task is the calculation of absorption frequencies as a function...the methyl C-H bonds, and n\\ and inn are the carbon and hydrogen atomic masses, respectively. The calculation of the fundamental and overtone

  13. A green-yellow emitting oxyfluoride solid solution phosphor Sr[subscript 2]Ba(AlO[subscript 4]F)[subscript 1;#8722;x](SiO[subscript 5])x:Ce[superscript 3+] for thermally stable, high color rendition solid state white lighting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denault, Kristin A.; George, Nathan C.; Paden, Sara R.

    2012-10-23

    A near-UV excited, oxyfluoride phosphor solid solution Sr{sub 1.975}Ce{sub 0.025}Ba(AlO{sub 4}F){sub 1-x}(SiO{sub 5}){sub x} has been developed for solid state white lighting applications. An examination of the host lattice, and the local structure around the Ce{sup 3+} activator ions through a combination of density functional theory, synchrotron X-ray and neutron powder diffraction and total scattering, and electron paramagnetic resonance, points to how chemical substitutions play a crucial role in tuning the optical properties of the phosphor. The maximum emission wavelength can be tuned from green ({lambda}{sub em} = 523 nm) to yellow ({lambda}{sub em} = 552 nm) by tuning themore » composition, x. Photoluminescent quantum yield is determined to be 70 {+-} 5% for some of the examples in the series. Excellent thermal properties were found for the x = 0.5 sample, with the photoluminescence intensity at 160 C only decreased to 82% of its room temperature value. Phosphor-converted LED devices fabricated using an InGaN LED ({lambda}{sub max} = 400 nm) exhibit high color rendering white light with R{sub a} = 70 and a correlated color temperature near 7000 K. The value of R{sub a} could be raised to 90 by the addition of a red component, and the correlated color temperature lowered to near 4000 K.« less

  14. A New Type of Frequency Chain and Its Application to Fundamental Frequency Metrology

    NASA Astrophysics Data System (ADS)

    Udem, Thomas; Reichert, Joerg; Holzwarth, Ronald; Diddams, Scott; Jones, David; Ye, Jun; Cundiff, Steven; Haensch, Theodor; Hall, John

    A suitable femtosecond (fs) laser system can provide a broad band comb of stable optical frequencies and thus can serve as an rf/optical coherent link. In this way we have performed a direct comparison of the 1S-2S transition in atomic hydrogen at 121 nm with a cesium fountain clock, built at the LPTF/Paris, to reach an accuracy of 1.9times 10^{-14}. The same comb-line counting technique was exploited to determine and recalibrate several important optical frequency standards. In particular, the improved measurement of the Cesium D1 line is necessary for a more precise determination of the fine structure constant. In addition, several of the best-known optical frequency standards have been recalibrated via the fs method. By creating an octave-spanning frequency comb a single-laser frequency chain has been realized and tested.

  15. A quantitative theory of gamma synchronization in macaque V1.

    PubMed

    Lowet, Eric; Roberts, Mark J; Peter, Alina; Gips, Bart; De Weerd, Peter

    2017-08-31

    Gamma-band synchronization coordinates brief periods of excitability in oscillating neuronal populations to optimize information transmission during sensation and cognition. Commonly, a stable, shared frequency over time is considered a condition for functional neural synchronization. Here, we demonstrate the opposite: instantaneous frequency modulations are critical to regulate phase relations and synchronization. In monkey visual area V1, nearby local populations driven by different visual stimulation showed different gamma frequencies. When similar enough, these frequencies continually attracted and repulsed each other, which enabled preferred phase relations to be maintained in periods of minimized frequency difference. Crucially, the precise dynamics of frequencies and phases across a wide range of stimulus conditions was predicted from a physics theory that describes how weakly coupled oscillators influence each other's phase relations. Hence, the fundamental mathematical principle of synchronization through instantaneous frequency modulations applies to gamma in V1 and is likely generalizable to other brain regions and rhythms.

  16. A fast and accurate frequency estimation algorithm for sinusoidal signal with harmonic components

    NASA Astrophysics Data System (ADS)

    Hu, Jinghua; Pan, Mengchun; Zeng, Zhidun; Hu, Jiafei; Chen, Dixiang; Tian, Wugang; Zhao, Jianqiang; Du, Qingfa

    2016-10-01

    Frequency estimation is a fundamental problem in many applications, such as traditional vibration measurement, power system supervision, and microelectromechanical system sensors control. In this paper, a fast and accurate frequency estimation algorithm is proposed to deal with low efficiency problem in traditional methods. The proposed algorithm consists of coarse and fine frequency estimation steps, and we demonstrate that it is more efficient than conventional searching methods to achieve coarse frequency estimation (location peak of FFT amplitude) by applying modified zero-crossing technique. Thus, the proposed estimation algorithm requires less hardware and software sources and can achieve even higher efficiency when the experimental data increase. Experimental results with modulated magnetic signal show that the root mean square error of frequency estimation is below 0.032 Hz with the proposed algorithm, which has lower computational complexity and better global performance than conventional frequency estimation methods.

  17. Fundamental Limit of 1/f Frequency Noise in Semiconductor Lasers Due to Mechanical Thermal Noise

    NASA Technical Reports Server (NTRS)

    Numata, K.; Camp, J.

    2011-01-01

    So-called 1/f noise has power spectral density inversely proportional to frequency, and is observed in many physical processes. Single longitudinal-mode semiconductor lasers, used in variety of interferometric sensing applications, as well as coherent communications, exhibit 1/f frequency noise at low frequency (typically below 100kHz). Here we evaluate mechanical thermal noise due to mechanical dissipation in semiconductor laser components and give a plausible explanation for the widely-observed 1/f frequency noise, applying a methodology developed for fixed-spacer cavities for laser frequency stabilization. Semiconductor-laser's short cavity, small beam radius, and lossy components are expected to emphasize thermal-noise-limited frequency noise. Our simple model largely explains the different 1/f noise levels observed in various semiconductor lasers, and provides a framework where the noise may be reduced with proper design.

  18. A quantitative theory of gamma synchronization in macaque V1

    PubMed Central

    Roberts, Mark J; Peter, Alina; Gips, Bart; De Weerd, Peter

    2017-01-01

    Gamma-band synchronization coordinates brief periods of excitability in oscillating neuronal populations to optimize information transmission during sensation and cognition. Commonly, a stable, shared frequency over time is considered a condition for functional neural synchronization. Here, we demonstrate the opposite: instantaneous frequency modulations are critical to regulate phase relations and synchronization. In monkey visual area V1, nearby local populations driven by different visual stimulation showed different gamma frequencies. When similar enough, these frequencies continually attracted and repulsed each other, which enabled preferred phase relations to be maintained in periods of minimized frequency difference. Crucially, the precise dynamics of frequencies and phases across a wide range of stimulus conditions was predicted from a physics theory that describes how weakly coupled oscillators influence each other’s phase relations. Hence, the fundamental mathematical principle of synchronization through instantaneous frequency modulations applies to gamma in V1 and is likely generalizable to other brain regions and rhythms. PMID:28857743

  19. High-frequency resonant-tunneling oscillators

    NASA Technical Reports Server (NTRS)

    Brown, E. R.; Parker, C. D.; Calawa, A. R.; Manfra, M. J.; Chen, C. L.

    1991-01-01

    Advances in high-frequency resonant-tunneling-diode (RTD) oscillators are described. Oscillations up to a frequency of 420 GHz have been achieved in the GaAs/AlAs system. Recent results obtained with In0.53Ga0.47As/AlAs and InAs/AlSb RTDs show a greatly increased power density and indicate the potential for fundamental oscillations up to about 1 THz. These results are consistent with a lumped-element equivalent circuit model of the RTD. The model shows that the maximum oscillation frequency of the GaAs/AlAs RTDs is limited primarily by series resistance, and that the power density is limited by low peak-to-valley current ratio.

  20. What is the Temporal Analog of Reflection and Refraction of Optical Beams?

    PubMed

    Plansinis, B W; Donaldson, W R; Agrawal, G P

    2015-10-30

    It is shown numerically and analytically that when an optical pulse approaches a moving temporal boundary across which the refractive index changes, it undergoes a temporal equivalent of reflection and refraction of optical beams at a spatial boundary. The main difference is that the role of angles is played by changes in the frequency. The frequency dependence of the dispersion of the material in which the pulse is propagating plays a fundamental role in determining the frequency shifts experienced by the reflected and refracted pulses. Our analytic expressions for these frequency shifts allow us to find the condition under which an analog of total internal reflection may occur at the temporal boundary.

  1. Sound transmission in ducts containing nearly choked flows

    NASA Technical Reports Server (NTRS)

    Callegari, A. J.; Myers, M. K.

    1979-01-01

    The nonlinear theory previously developed by the authors (1977, 1978) is used to obtain numerical results for sound transmission through a nearly choked throat in a variable-area duct. Parametric studies are performed for different source locations, strengths and frequencies. It is shown that the nonlinear interactions in the throat region generate superharmonics of the fundamental (source) frequency throughout the duct. The amplitudes of these superharmonics increase as the source parameters (frequency and strength) are increased toward values leading to acoustic shocks. For a downstream source, superharmonics carry about 20% of the total acoustic power as shocking conditions are approached. For the source strength levels and frequencies considered, streaming effects are negligible.

  2. Online frequency estimation with applications to engine and generator sets

    NASA Astrophysics Data System (ADS)

    Manngård, Mikael; Böling, Jari M.

    2017-07-01

    Frequency and spectral analysis based on the discrete Fourier transform is a fundamental task in signal processing and machine diagnostics. This paper aims at presenting computationally efficient methods for real-time estimation of stationary and time-varying frequency components in signals. A brief survey of the sliding time window discrete Fourier transform and Goertzel filter is presented, and two filter banks consisting of: (i) sliding time window Goertzel filters (ii) infinite impulse response narrow bandpass filters are proposed for estimating instantaneous frequencies. The proposed methods show excellent results on both simulation studies and on a case study using angular speed data measurements of the crankshaft of a marine diesel engine-generator set.

  3. Low-frequency noise reduction of lightweight airframe structures

    NASA Technical Reports Server (NTRS)

    Getline, G. L.

    1976-01-01

    The results of an experimental study to determine the noise attenuation characteristics of aircraft type fuselage structural panels were presented. Of particular interest was noise attenuation at low frequencies, below the fundamental resonances of the panels. All panels were flightweight structures for transport type aircraft in the 34,050 to 45,400 kg (75,000 to 100,000 pounds) gross weight range. Test data include the results of vibration and acoustic transmission loss tests on seven types of isotropic and orthotropically stiffened, flat and curved panels. The results show that stiffness controlled acoustically integrated structures can provide very high noise reductions at low frequencies without significantly affecting their high frequency noise reduction capabilities.

  4. A passion for precision

    ScienceCinema

    Hänsch, Theodor W.

    2018-05-23

    For more than three decades, the quest for ever higher precision in laser spectroscopy of the simple hydrogen atom has inspired many advances in laser, optical, and spectroscopic techniques, culminating in femtosecond laser optical frequency combs  as perhaps the most precise measuring tools known to man. Applications range from optical atomic clocks and tests of QED and relativity to searches for time variations of fundamental constants. Recent experiments are extending frequency comb techniques into the extreme ultraviolet. Laser frequency combs can also control the electric field of ultrashort light pulses, creating powerful new tools for the emerging field of attosecond science.

  5. Perceptual Audio Hashing Functions

    NASA Astrophysics Data System (ADS)

    Özer, Hamza; Sankur, Bülent; Memon, Nasir; Anarım, Emin

    2005-12-01

    Perceptual hash functions provide a tool for fast and reliable identification of content. We present new audio hash functions based on summarization of the time-frequency spectral characteristics of an audio document. The proposed hash functions are based on the periodicity series of the fundamental frequency and on singular-value description of the cepstral frequencies. They are found, on one hand, to perform very satisfactorily in identification and verification tests, and on the other hand, to be very resilient to a large variety of attacks. Moreover, we address the issue of security of hashes and propose a keying technique, and thereby a key-dependent hash function.

  6. Effects of laser source parameters on the generation of narrow band and directed laser ultrasound

    NASA Technical Reports Server (NTRS)

    Spicer, James B.; Deaton, John B., Jr.; Wagner, James W.

    1992-01-01

    Predictive and prescriptive modeling of laser arrays is performed to demonstrate the effects of the extension of array elements on laser array performance. For a repetitively pulsed laser source (the temporal laser array), efficient frequency compression is best achieved by detecting longitudinal waves off-epicenter in plates where the source size and shape directly influence the longitudinal wave shape and duration; the longitudinal array may be tailored for a given repetition frequency to yield efficient overtone energy compression into the fundamental frequency band. For phased arrays, apparent array directivity is heavily influenced by array element size.

  7. Theoretical analysis of optical poling and frequency doubling effect based on classical model

    NASA Astrophysics Data System (ADS)

    Feng, Xi; Li, Fuquan; Lin, Aoxiang; Wang, Fang; Chai, Xiangxu; Wang, Zhengping; Zhu, Qihua; Sun, Xun; Zhang, Sen; Sun, Xibo

    2018-03-01

    Optical poling and frequency doubling effect is one of the effective manners to induce second order nonlinearity and realize frequency doubling in glass materials. The classical model believes that an internal electric field is built in glass when it's exposed by fundamental and frequency-doubled light at the same time, and second order nonlinearity appears as a result of the electric field and the orientation of poles. The process of frequency doubling in glass is quasi phase matched. In this letter, the physical process of poling and doubling process in optical poling and frequency doubling effect is deeply discussed in detail. The magnitude and direction of internal electric field, second order nonlinear coefficient and its components, strength and direction of frequency doubled output signal, quasi phase matched coupled wave equations are given in analytic expression. Model of optical poling and frequency doubling effect which can be quantitatively analyzed are constructed in theory, which set a foundation for intensive study of optical poling and frequency doubling effect.

  8. Utility of Higher Harmonics in Electrospray Ionization Fourier Transform Electrostatic Linear Ion Trap Mass Spectrometry.

    PubMed

    Dziekonski, Eric T; Johnson, Joshua T; McLuckey, Scott A

    2017-04-18

    Mass resolution (M/ΔM fwhm) is observed to linearly increase with harmonic order in a Fourier transform electrostatic linear ion trap (ELIT) mass spectrometer. This behavior was predicted by Grosshans and Marshall for frequency-multiple detection in a Fourier transform ion cyclotron resonance mass spectrometer only for situations when the prominent mechanism for signal decay is ion ejection from the trap. As the analyzer pressure in our ELIT chamber is relatively high, such that collisional scattering and collision-induced dissociation are expected to underlie much of the ion loss, we sought to explore the relationship between harmonic order and mass resolution. Mass resolutions of 36 900 (fundamental), 75 850 (2nd harmonic), and 108 200 (3rd harmonic) were obtained for GdO + (avg. m/z 173.919) with a transient length of 300 ms. To demonstrate that the mass resolution was truly increasing with harmonic order, the unresolved isotopes at the fundamental distribution of cytochrome c +8 (m/z ∼ 1549) were nearly baseline, resolved at the third harmonic (mass resolution ≈ 23 000) with a transient length of only 200 ms. This experiment demonstrates that, when the ion density is sufficiently low, ions with frequency differences of less than 4 Hz remain uncoalesced. Higher harmonics can be used to increase the effective mass resolution for a fixed transient length and thereby may enable the resolution of closely spaced masses, determination of a protein ion's charge state, and study of the onset of peak coalescence when the resolution at the fundamental frequency is insufficient.

  9. Quantitative infrared and near-infrared gas-phase spectra for pyridine: Absolute intensities and vibrational assignments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, T. J.; Aker, P. M.; Scharko, N. K.

    Using vetted methods for generating quantitative absorption reference data, broadband infrared and near-infrared spectra (total range 11,000 – 600 cm-1) of pyridine vapor were recorded at 0.1 cm-1 spectral resolution, with the analyte thermostatted at 298 K and pressure-broadened to 1 atmosphere using N2 ballast gas. The quantitative spectrum is reported for the first time, and we have re-assigned some of the 27 fundamental modes. Fundamental assignments were confirmed by IR vapor phase band shapes, FT-Raman measurements and comparison with previous analyses. For the 760-Torr vapor-phase IR data several bands show resolved peaks (Q-branches). We have also assigned for themore » first time hundreds of combination and overtone bands in the mid- and near-IR. All assignments were made via comparison to theoretically calculated frequencies and intensities: The frequencies were computed with Gaussian03 with the anharmonic option, using MP2 and the ccpvtz basis set. The intensities were taken from a VSCF calculation in GAMESS using Hartree-Fock (for overtones and combination bands) or from the harmonic MP2 for fundamentals. Overtone and combination band harmonic and anharmonic frequencies, as well as intensities were also calculated using the CFOUR program. It is seen in the NIR spectrum near 6000 cm-1 that the very strong bands arise from the C-H first overtones, whereas only much weaker bands are observed for combination bands of C-H stretching modes. Certain features are discussed for their potential utility for atmospheric monitoring.« less

  10. Quantification of site-city interaction effects on the response of structure under double resonance condition

    NASA Astrophysics Data System (ADS)

    Kumar, Neeraj; Narayan, Jay Prakash

    2018-01-01

    This paper presents the site-city interaction (SCI) effects on the response of closely spaced structures under double resonance condition (F_{02{{D}}}^{{S}} = F_{02{{D}}}^{{B}}), where F_{02{{D}}}^{{S}} and F_{02{{D}}}^{{B}} are fundamental frequencies of 2-D structure and 2-D basin, respectively. This paper also presents the development of empirical relations to predict the F_{02{{D}}}^{{B}} of elliptical and trapezoidal basins for both the polarizations of the S wave. Simulated results revealed that F_{02{{D}}}^{{B}} of a 2-D basin very much depends on its geometry, shape ratio and polarization of the incident S wave. The obtained spectral amplification factor (SAF) at F_{02{{D}}}^{{S}} of a standalone structure in a 2-D basin is greater than that in the 1-D case under double resonance condition. A considerable reduction of the fundamental resonance frequency of structures due to the SCI effects is observed for both the polarizations of the S wave. The SAFs at F_{02{{D}}}^{{S}} of closely spaced structures due to SCI effects is larger in the case of SV than SH waves. A splitting of the fundamental-mode frequency bandwidth along with the drastic decrease of SAF due to the SCI effects is obtained. The findings of this paper raise the question concerning the validity of the predicted response of standalone structure based on soil-structure interaction for the design of structures in a 2-D small basin, in an urban environment.

  11. Distinct Acoustic Features and Glottal Changes Define Two Modes of Singing in Peking Opera.

    PubMed

    Li, Gelin; Li, Haiqing; Hou, Qian; Jiang, Zhen

    2018-04-06

    We aimed to delineate the acoustic characteristics of the Laodan and Qingyi role in Peking Opera and define glottis closure states and mucosal wave changes during singing in the two roles. The range of singing in A4 (440 Hz) pitch in seven female Peking Opera singers was determined using two classic pieces of Peking Opera. Glottal changes during singing were examined by stroboscopic laryngoscope. The fundamental frequency of /i/ in the first 15 seconds of the two pieces and the /i/ pitch range were determined. The relative length of the glottis fissure and the relative maximum mucosal amplitude were calculated. Qingyi had significantly higher mean fundamental frequency than Laodan. The long-term average spectrum showed an obvious formant cluster near 3000 Hz in Laodan versus Qingyi. No formant cluster was observed in singing in the regular mode. Strobe laryngoscopy showed complete glottal closure in Laodan and incomplete glottal closure in Qingyi in the maximal glottis closure phase. The relative length of the glottis fissure of Laodan was significantly lower than that of Qingyi in the singing mode. The relative maximum mucosal amplitude of Qingyi was significantly lower than that of Laodan. The Laodan role and the Qingyi role in Peking Opera sing in a fundamental frequency range compatible with the respective use of da sang (big voice) and xiao sang (small voice). The morphological patterns of glottal changes also indicate that the Laodan role and the Qingyi role sing with da sang and xiao sang, respectively. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  12. Parametric Amplification Protocol for Frequency-Modulated Magnetic Resonance Force Microscopy Signals

    NASA Astrophysics Data System (ADS)

    Harrell, Lee; Moore, Eric; Lee, Sanggap; Hickman, Steven; Marohn, John

    2011-03-01

    We present data and theoretical signal and noise calculations for a protocol using parametric amplification to evade the inherent tradeoff between signal and detector frequency noise in force-gradient magnetic resonance force microscopy signals, which are manifested as a modulated frequency shift of a high- Q microcantilever. Substrate-induced frequency noise has a 1 / f frequency dependence, while detector noise exhibits an f2 dependence on modulation frequency f . Modulation of sample spins at a frequency that minimizes these two contributions typically results in a surface frequency noise power an order of magnitude or more above the thermal limit and may prove incompatible with sample spin relaxation times as well. We show that the frequency modulated force-gradient signal can be used to excite the fundamental resonant mode of the cantilever, resulting in an audio frequency amplitude signal that is readily detected with a low-noise fiber optic interferometer. This technique allows us to modulate the force-gradient signal at a sufficiently high frequency so that substrate-induced frequency noise is evaded without subjecting the signal to the normal f2 detector noise of conventional demodulation.

  13. An approximation function for frequency constrained structural optimization

    NASA Technical Reports Server (NTRS)

    Canfield, R. A.

    1989-01-01

    The purpose is to examine a function for approximating natural frequency constraints during structural optimization. The nonlinearity of frequencies has posed a barrier to constructing approximations for frequency constraints of high enough quality to facilitate efficient solutions. A new function to represent frequency constraints, called the Rayleigh Quotient Approximation (RQA), is presented. Its ability to represent the actual frequency constraint results in stable convergence with effectively no move limits. The objective of the optimization problem is to minimize structural weight subject to some minimum (or maximum) allowable frequency and perhaps subject to other constraints such as stress, displacement, and gage size, as well. A reason for constraining natural frequencies during design might be to avoid potential resonant frequencies due to machinery or actuators on the structure. Another reason might be to satisy requirements of an aircraft or spacecraft's control law. Whatever the structure supports may be sensitive to a frequency band that must be avoided. Any of these situations or others may require the designer to insure the satisfaction of frequency constraints. A further motivation for considering accurate approximations of natural frequencies is that they are fundamental to dynamic response constraints.

  14. A Novel Ku-Band/Ka-Band and Ka-Band/E-Band Multimode Waveguide Couplers for Power Measurement of Traveling-Wave Tube Amplifier Harmonic Frequencies

    NASA Technical Reports Server (NTRS)

    Wintucky, Edwin G.; Simons, Rainee N.

    2015-01-01

    This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler, fabricated from two dissimilar frequency band waveguides, is capable of isolating power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT) amplifier. Test results from proof-of-concept demonstrations are presented for a Ku-band/Ka-band MDC and a Ka-band/E-band MDC. In addition to power measurements at harmonic frequencies, a potential application of the MDC is in the design of a satellite borne beacon source for atmospheric propagation studies at millimeter-wave (mm-wave) frequencies (Ka-band and E-band).

  15. A 15-pole high temperature superconductor filter for radar applications

    NASA Astrophysics Data System (ADS)

    Yu, Xiao; Xi, Weibin; Wu, Songtao

    2018-06-01

    This paper presents a compact and high first harmonic frequency resonator. The characteristics of this resonator are theoretically analyzed. A highly selective 15-pole Chebyshev high temperature superconducting ultra-high frequency narrowband filter for radar applications was fabricated by using this resonator. The filter has a center frequency of 495 MHz and a fractional bandwidth of 1%. The first harmonic frequency is more than 3.3 times the fundamental frequency. The measured filter shows excellent selectivity, better than 85 dB/1 MHz skirt slopes, and more than 85 dB of rejection at 497.5 MHz from the band edge. The filter was fabricated on a 2 inch YBCO thin film with a 0.5 mm thick MgO substrate. The experimental results are consistent with the simulations.

  16. Formant frequencies in country singers' speech and singing.

    PubMed

    Stone, R E; Cleveland, T F; Sundberg, J

    1999-06-01

    In previous investigations breathing kinematics, subglottal pressures, and voice source characteristics of a group of premier country singers have been analyzed. The present study complements the description of these singers' voice properties by examining the formant frequencies in five of these country singers' spoken and sung versions of the national anthem and of a song of their own choosing. The formant frequencies were measured for identical phonemes under both conditions. Comparisons revealed that the singers used the same or slightly higher formant frequencies when they were singing than when they were speaking. The differences may be related to the higher fundamental frequency in singing. These findings are in good agreement with previous observations regarding breathing, subglottal pressures, and voice source, but are in marked contrast to what has been found for classically trained singers.

  17. Harmonic magneto-electric response in GaFeO3

    NASA Astrophysics Data System (ADS)

    Naiya, Amit Kumar; Awasthi, A. M.

    2018-04-01

    GaFeO3 is a well-known multiferroic material. Like optical second harmonic generation, it also generates radio frequency (RF) second harmonic due to its non-centrosymmetric orthorhombic structure. The harmonic RF response also features a magneto-electric character comparable in prominence to that of the fundamental response. We measured complex parts of the fundamental and the second harmonic over 80 K to 300 K. The second harmonic permittivity and its phase angle change sign at the spin glass transition temperature Tg = 200 K and becomes dispersive above ˜280 K.

  18. Development of Translational Methods in Spectral Analysis of Human Infant Crying and Rat Pup Ultrasonic Vocalizations for Early Neurobehavioral Assessment

    PubMed Central

    Zeskind, Philip Sanford; McMurray, Matthew S.; Garber, Kristin A.; Neuspiel, Juliana M.; Cox, Elizabeth T.; Grewen, Karen M.; Mayes, Linda C.; Johns, Josephine M.

    2011-01-01

    The purpose of this article is to describe the development of translational methods by which spectrum analysis of human infant crying and rat pup ultrasonic vocalizations (USVs) can be used to assess potentially adverse effects of various prenatal conditions on early neurobehavioral development. The study of human infant crying has resulted in a rich set of measures that has long been used to assess early neurobehavioral insult due to non-optimal prenatal environments, even among seemingly healthy newborn and young infants. In another domain of study, the analysis of rat put USVs has been conducted via paradigms that allow for better experimental control over correlated prenatal conditions that may confound findings and conclusions regarding the effects of specific prenatal experiences. The development of translational methods by which cry vocalizations of both species can be analyzed may provide the opportunity for findings from the two approaches of inquiry to inform one another through their respective strengths. To this end, we present an enhanced taxonomy of a novel set of common measures of cry vocalizations of both human infants and rat pups based on a conceptual framework that emphasizes infant crying as a graded and dynamic acoustic signal. This set includes latency to vocalization onset, duration and repetition rate of expiratory components, duration of inter-vocalization-intervals and spectral features of the sound, including the frequency and amplitude of the fundamental and dominant frequencies. We also present a new set of classifications of rat pup USV waveforms that include qualitative shifts in fundamental frequency, similar to the presence of qualitative shifts in fundamental frequency that have previously been related to insults to neurobehavioral integrity in human infants. Challenges to the development of translational analyses, including the use of different terminologies, methods of recording, and spectral analyses are discussed, as well as descriptions of automated processes, software solutions, and pitfalls. PMID:22028695

  19. SPECIAL ISSUE DEVOTED TO THE 80TH BIRTHDAY OF S.A. AKHMANOV: Selective generation of a higher harmonic in plasma

    NASA Astrophysics Data System (ADS)

    Kulagin, I. A.; Usmanov, T.

    2009-07-01

    It is shown for the first time that the use of autoionisation states for phase matching leads to the efficient selection of a single harmonic generated in a plateau region in plasma. The selected harmonic frequency can be tuned by changing the relative concentration of plasma components and tuning the fundamental radiation frequency. It is shown that the contrast of the selected harmonic can exceed 104.

  20. A heuristic method for identifying chaos from frequency content.

    PubMed

    Wiebe, R; Virgin, L N

    2012-03-01

    The sign of the largest Lyapunov exponent is the fundamental indicator of chaos in a dynamical system. However, although the extraction of Lyapunov exponents can be accomplished with (necessarily noisy) the experimental data, this is still a relatively data-intensive and sensitive endeavor. This paper presents an alternative pragmatic approach to identifying chaos using response frequency characteristics and extending the concept of the spectrogram. The method is shown to work well on both experimental and simulated time series.

  1. Resonant-cavity antenna for plasma heating

    DOEpatents

    Perkins, F.W. Jr.; Chiu, S.C.; Parks, P.; Rawls, J.M.

    1984-01-10

    This invention relates generally to a method and apparatus for transferring energy to a plasma immersed in a magnetic field, and relates particularly to an apparatus for heating a plasma of low atomic number ions to high temperatures by transfer of energy to plasma resonances, particularly the fundamental and harmonics of the ion cyclotron frequency of the plasma ions. This invention transfers energy from an oscillating radio-frequency field to a plasma resonance of a plasma immersed in a magnetic field.

  2. A study of voice production characteristics of astronuat speech during Apollo 11 for speaker modeling in space.

    PubMed

    Yu, Chengzhu; Hansen, John H L

    2017-03-01

    Human physiology has evolved to accommodate environmental conditions, including temperature, pressure, and air chemistry unique to Earth. However, the environment in space varies significantly compared to that on Earth and, therefore, variability is expected in astronauts' speech production mechanism. In this study, the variations of astronaut voice characteristics during the NASA Apollo 11 mission are analyzed. Specifically, acoustical features such as fundamental frequency and phoneme formant structure that are closely related to the speech production system are studied. For a further understanding of astronauts' vocal tract spectrum variation in space, a maximum likelihood frequency warping based analysis is proposed to detect the vocal tract spectrum displacement during space conditions. The results from fundamental frequency, formant structure, as well as vocal spectrum displacement indicate that astronauts change their speech production mechanism when in space. Moreover, the experimental results for astronaut voice identification tasks indicate that current speaker recognition solutions are highly vulnerable to astronaut voice production variations in space conditions. Future recommendations from this study suggest that successful applications of speaker recognition during extended space missions require robust speaker modeling techniques that could effectively adapt to voice production variation caused by diverse space conditions.

  3. GaN-on-Silicon - Present capabilities and future directions

    NASA Astrophysics Data System (ADS)

    Boles, Timothy

    2018-02-01

    Gallium Nitride, in the form of epitaxial HEMT transistors on various substrate materials, is the newest and most promising semiconductor technology for high performance devices in the RF, microwave, and mmW arenas. This is particularly true for GaN-on-Silicon based devices and MMIC's which enable both state-of-the-art high frequency functionality and the ability to scale production into large wafer diameter CMOS foundries. The design and development of GaN-on-Silicon structures and devices will be presented beginning with the basic material parameters, growth of the required epitaxial construction, and leading to the fundamental operational theory of high frequency, high power HEMTs. In this discussion comparisons will be made with alternative substrate materials with emphasis on contrasting the inherent advantages of a silicon based system. Theory of operation of microwave and mmW high power HEMT devices will be presented with special emphasis on fundamental limitations of device performance including inherent frequency limiting transit time analysis, required impedance transformations, internal and external parasitic reactance, thermal impedance optimization, and challenges improved by full integration into monolithic MMICs. Lastly, future directions for implementing GaN-on-Silicon into mainstream CMOS silicon semiconductor technologies will be discussed.

  4. Modeling of induction-linac based free-electron laser amplifiers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jong, R.A.; Fawley, W.M.; Scharlemann, E.T.

    We describe the modeling of an induction-linac based free-electron laser (IFEL) amplifier for producing multimegawatt levels of microwave power. We have used the Lawrence Livermore National Laboratory (LLNL) free-electron laser simulation code, FRED, and the simulation code for sideband calculations, GINGER for this study. For IFEL amplifiers in the frequency range of interest (200 to 600 GHz), we have devised a wiggler design strategy which incorporates a tapering algorithm that is suitable for free-electron laser (FEL) systems with moderate space-charge effects and that minimizes spontaneous noise growth at frequencies below the fundamental, while enhancing the growth of the signal atmore » the fundamental. In addition, engineering design considerations of the waveguide wall loading and electron beam fill factor in the waveguide set limits on the waveguide dimensions, the wiggler magnet gap spacing, the wiggler period, and the minimum magnetic field strength in the tapered region of the wiggler. As an example, we shall describe an FEL amplifier designed to produce an average power of about 10 MW at a frequency of 280 GHz to be used for electron cyclotron resonance heating of tokamak fusion devices. 17 refs., 4 figs.« less

  5. Power system frequency estimation based on an orthogonal decomposition method

    NASA Astrophysics Data System (ADS)

    Lee, Chih-Hung; Tsai, Men-Shen

    2018-06-01

    In recent years, several frequency estimation techniques have been proposed by which to estimate the frequency variations in power systems. In order to properly identify power quality issues under asynchronously-sampled signals that are contaminated with noise, flicker, and harmonic and inter-harmonic components, a good frequency estimator that is able to estimate the frequency as well as the rate of frequency changes precisely is needed. However, accurately estimating the fundamental frequency becomes a very difficult task without a priori information about the sampling frequency. In this paper, a better frequency evaluation scheme for power systems is proposed. This method employs a reconstruction technique in combination with orthogonal filters, which may maintain the required frequency characteristics of the orthogonal filters and improve the overall efficiency of power system monitoring through two-stage sliding discrete Fourier transforms. The results showed that this method can accurately estimate the power system frequency under different conditions, including asynchronously sampled signals contaminated by noise, flicker, and harmonic and inter-harmonic components. The proposed approach also provides high computational efficiency.

  6. Bilateral coordination and the motor basis of female preference for sexual signals in canary song

    PubMed Central

    Suthers, Roderick A.; Vallet, Eric; Kreutzer, Michel

    2012-01-01

    SUMMARY The preference of female songbirds for particular traits in the songs of courting males has received considerable attention, but the relationship of preferred traits to male quality is poorly understood. Female domestic canaries (Serinus canaria, Linnaeus) preferentially solicit copulation with males that sing special high repetition rate, wide-band, multi-note syllables, called ‘sexy’ or A-syllables. Syllables are separated by minibreaths but each note is produced by pulsatile expiration, allowing high repetition rates and long duration phrases. The wide bandwidth is achieved by including two notes produced sequentially on opposite sides of the syrinx, in which the left and right sides are specialized for low or high frequencies, respectively. The emphasis of low frequencies is facilitated by a positive relationship between syllable repetition rate and the bandwidth of the fundamental frequency of notes sung by the left syrinx, such that bandwidth increases with increasing syllable repetition rate. The temporal offset between notes prevents cheating by unilaterally singing a note on the left side with a low fundamental frequency and prominent higher harmonics. The syringeal and respiratory motor patterns by which sexy syllables are produced support the hypothesis that these syllables provide a sensitive vocal–auditory indicator of a male's performance limit for the rapid, precisely coordinated interhemispheric switching, which is essential for many sensory and motor processes involving specialized contributions from each cerebral hemisphere. PMID:22875764

  7. Vibration analysis of partially cracked plate submerged in fluid

    NASA Astrophysics Data System (ADS)

    Soni, Shashank; Jain, N. K.; Joshi, P. V.

    2018-01-01

    The present work proposes an analytical model for vibration analysis of partially cracked rectangular plates coupled with fluid medium. The governing equation of motion for the isotropic plate based on the classical plate theory is modified to accommodate a part through continuous line crack according to simplified line spring model. The influence of surrounding fluid medium is incorporated in the governing equation in the form of inertia effects based on velocity potential function and Bernoulli's equations. Both partially and totally submerged plate configurations are considered. The governing equation also considers the in-plane stretching due to lateral deflection in the form of in-plane forces which introduces geometric non-linearity into the system. The fundamental frequencies are evaluated by expressing the lateral deflection in terms of modal functions. The assessment of the present results is carried out for intact submerged plate as to the best of the author's knowledge the literature lacks in analytical results for submerged cracked plates. New results for fundamental frequencies are presented as affected by crack length, fluid level, fluid density and immersed depth of plate. By employing the method of multiple scales, the frequency response and peak amplitude of the cracked structure is analyzed. The non-linear frequency response curves show the phenomenon of bending hardening or softening and the effect of fluid dynamic pressure on the response of the cracked plate.

  8. LIF excitation spectra for S 0 → S 1 transition of deuterated anthranilic acid COOD, ND 2 in supersonic-jet expansion

    NASA Astrophysics Data System (ADS)

    Kolek, Przemysław; Leśniewski, Sebastian; Andrzejak, Marcin; Góra, Maciej; Cias, Pawel; Weģrzynowicz, Adam; Najbar, Jan

    2010-12-01

    Laser induced fluorescence (LIF) excitation spectrum for the S 0 → S 1 transition of anthranilic acid molecules deuterated in the substituent groups (COOD, ND 2) was investigated. Analysis of the LIF spectrum allowed for the assignment of the six most prominent fundamental in-plane modes of frequencies up to ca. 850 cm. The experimental results show good correlation with the frequency changes upon deuteration computed with CIS (CI-Singles) and TD-DFT for the S 1 state. Deuteration induced red-shifts of the identified fundamental bands are used for examination of the alternative assignments proposed in earlier studies. Potential energy distributions (PED) and overlaps of the in-plane normal modes with frequencies below 850 cm indicate that the correspondence of the respective vibrations of the deuterated and non-deuterated molecule is very good. A blue-shift of the 00 transition due to the isotopic substitution, is equal to 47 cm. This relatively large value is caused primarily by a significant decrease of the N-H stretching frequency associated with the increase of strength of the intramolecular hydrogen bond upon the electronic excitation. The deuteration shift of the 00 band was interpreted in terms of the differences of the zero point energy (ZPE) between the S 0 and S 1 electronic states, computed with DFT and TD-DFT methods, respectively.

  9. Accurate ab Initio Quartic Force Fields, Vibrational Frequencies, and Heats of Formation for FCN, FNC, ClCN, and ClNC

    NASA Technical Reports Server (NTRS)

    Lee, Timothy J.; Martin, Jan M. L.; Dateo, Christopher E.; Taylor, Peter R.

    1995-01-01

    The XCN and XNC (X = F, Cl) isomers have been investigated using the CCSD(T) method in conjunction with correlation consistent basis sets. Equilibrium geometries, harmonic frequencies, anharmonic constants, fundamental frequencies, and heats of formation have been evaluated. Agreement with experiment for the fundamental frequencies is very good, even for nu(sub 2), for CICN, which is subject to a strong Fermi resonance with 2nu(sub 3). It is also shown that a second-order perturbation theory approach to solving the nuclear Schroedinger equation gives results in excellent agreement with essentially exact variational calculations. This is true even for nu(sub 2) of ClCN, provided that near-singular terms are eliminated from the perturbation theory formulas and the appropriate Fermi interaction energy matrix is then diagonalized. A band at 615/cm, tentatively assigned as the Cl-N stretch in ClNC in matrix isolation experiments, is shown not to be due to ClNC. Accurate atomization energies are determined and are used to evaluate accurate heats of formation (3.1 +/- 1.5, 33.2 +/- 1.5, 72.6 +/- 1.5, and 75.9 +/- 1.5 kcal/mol for FCN, ClCN, FNC, and ClNC, respectively). It is expected that the theoretical heats of formation for FCN, FNC, and ClNC are the most accurate available.

  10. Acoustic and Auditory Perception Effects of the Voice Therapy Technique Finger Kazoo in Adult Women.

    PubMed

    Christmann, Mara Keli; Cielo, Carla Aparecida

    2017-05-01

    This study aimed to verify and to correlate acoustic and auditory-perceptual measures of glottic source after the performance of finger kazoo (FK) technique. This is an experimental, cross-sectional, and qualitative study. We made an analysis of the vowel [a:] in 46 adult women with neither vocal complaints nor laryngeal alterations, through the Multi-Dimensional Voice Program Advanced and RASATI scale, before and immediately after performing three series of FK and 5 minutes after a period of silence. Kappa, Friedman, Wilcoxon, and Spearman tests were used. We found significant increase in fundamental frequency, reduction of amplitude variation, and degree of sub-harmonics immediately after performing FK. Positive correlations were measures of frequency and its perturbation, measures of amplitude, of soft phonation index, of degree and number of unvoiced segments with aspects of RASATI. Negative correlations were voice turbulence index, measures of frequency and its perturbation, and measures of soft phonation index with aspects of RASATI. There was fundamental frequency increase, within normal limits, and reduction of acoustic measures related to presence of noise and instability. In general, acoustic measures, suggestive of noise and instability, were reduced according to the decrease of perceptive-auditory aspects of vocal alteration. It shows that both instruments are complementary and that the acoustic vocal effect was positive. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  11. Modal Analysis of Two Bridges, Bryce Canyon National Park

    NASA Astrophysics Data System (ADS)

    Geimer, P. R.; Moore, J. R.; Thorne, M. S.; Quirk, B.

    2016-12-01

    We used ambient seismic data to identify the primary resonant frequencies of the up-canyon span of Two Bridges, a natural sandstone arch located in Bryce Canyon National Park, Utah. Two broadband seismometers placed on the span recorded continuous data for 14 hours, which were compared to measurements from a nearby reference station. Spectral peaks identified in the recordings represent resonant modes of the arch. We observed a slight drift in the fundamental frequency, which we attribute to daily changes in rock temperature and associated thermal stresses. However, no detectable vertical motion was recorded over the same time period using a laser distance meter. We applied slight impulses to the arch along its main axes to experimentally determine modal damping ratios, which describe the vibrational properties of the arch. Ground-based photogrammetry was then used to construct a new 3D model of the feature, which we imported into COMSOL Multiphysics to perform numerical modal analyses. By varying the material properties, we were able to match the fundamental resonant frequency of the arch and several higher order modes, as well as associated polarization attributes. Repeat resonant frequency measurements at Two Bridges will help us better understand how the structure changes over time in response to environment factors. The Claron Formation, which forms Two Bridges, is highly susceptible to weathering and erosion making natural hazards, such as rock falls, a frequent occurrence in Bryce Canyon.

  12. Performance analysis of cascaded h-bridge multilevel inverter using mixed switching frequency with various dc-link voltages

    NASA Astrophysics Data System (ADS)

    Citarsa, I. B. F.; Satiawan, I. N. W.; Wiryajati, I. K.; Supriono

    2016-01-01

    Multilevel inverters have been widely used in many applications since the technology is advantageous to increase the converter capability as well as to improve the output voltage quality. According to the applied switching frequency, multilevel modulations can be subdivided into three classes, i.e: fundamental switching frequency, high switching frequency and mixed switching frequency. This paper investigates the performance of cascaded H-bridge (CHB) multilevel inverter that is modulated using mixed switching frequency (MSF) PWM with various dc-link voltage ratios. The simulation results show the nearly sinusoidal load output voltages are successfully achieved. It is revealed that there is improvement in output voltages quality in terms of THD and low-order harmonics content. The CHB inverter that is modulated using MSF PWM with equal dc-link voltage ratio (½ Vdc: ½ Vdc) produces output voltage with the lowest low-order harmonics (less than 1% of fundamental) while the CHB inverter that is modulated using MSF PWM with un-equal dc-link voltage ratio (2/3 Vdc: 1/3 Vdc) produces a 7-level output voltage with the lowest THD (16.31%) compared to the other PWM methods. Improvement of the output voltage quality here is also in line with improvement of the number of available levels provided in the output voltage. Here only 2 cells H-bridge inverter (contain 8 switches) are needed to produce a 7- level output voltage, while in the conventional CHB inverter at least 3 cells of H-bridge inverter (contain 12 switches) are needed to produce a 7-level output voltage. Hence it is valuable in term of saving number of component.

  13. Ion Acoustic Wave Frequencies and Onset Times During Type 3 Solar Radio Bursts

    NASA Technical Reports Server (NTRS)

    Cairns, Iver H.; Robinson, P. A.

    1995-01-01

    Conflicting interpretations exist for the low-frequency ion acoustic (S) waves often observed by ISEE 3 in association with intense Langmuir (L) waves in the source regions of type III solar radio bursts near 1 AU. Two indirect lines of observational evidence, as well as plasma theory, suggest they are produced by the electrostatic (ES) decay L yields L(PRIME) + S. However, contrary to theoretical predictions, an existing analysis of the wave frequencies instead favors the electromagnetic (EM) decays L yields T + S, where T denotes an EM wave near the plasma frequency. This conflict is addressed here by comparing the observed wave frequencies and onset times with theoretical predictions for the ES and EM decays, calculated using the time-variable electron beam and magnetic field orientation data, rather than the nominal values used previously. Field orientation effects and beam speed variations are shown analytically to produce factor-of-three effects, greater than the difference in wave frequencies predicted for the ES and EM decays; effects of similar magnitude occur in the events analyzed here. The S-wave signals are extracted by hand from a sawtooth noise background, greatly improving the association between S waves and intense L waves. Very good agreement exists between the time-varying predictions for the ES decay and the frequencies of most (but not all) wave bursts. The waves occur only after the ES decay becomes kinematically allowed, which is consistent with the ES decay proceeding and producing most of the observed signals. Good agreement exists between the EM decay's predictions and a significant fraction of the S-wave observations while the EM decay is kinematically allowed. The wave data are not consistent, however, with the EM decay being the dominant nonlinear process. Often the observed waves are sufficiently broadband to overlap simultaneously the frequency ranges predicted for the ES and EM decays. Coupling the dominance of the ES decay with this frequency overlap provides support for a previous suggestion that fundamental emission occurs when the EM decay is stimulated by the ES decay product waves. The periods in which the ES and EM decays produce observable S waves are consistent with the observed and (independently) predicted times of fundamental and harmonic radio emission. This supports interpretation of fundamental emission as stimulated EM decay and harmonic emission as the coalescence L + L(prime) yields T of beam-generated L waves and L(prime) waves produced by the ES decay, where T denotes an electromagnetic wave at twice the plasma frequency. Analysis of the electron beam data reveals that the time-varying beam speed is consistent with ballistic beam propagation with minimal energy loss, implying that the beam propagates in a state close to time- and volume-averaged marginal stability. This confirms a central tenet of the stochastic growth theory for type III bursts.

  14. Explicit frequency equations of free vibration of a nonlocal Timoshenko beam with surface effects

    NASA Astrophysics Data System (ADS)

    Zhao, Hai-Sheng; Zhang, Yao; Lie, Seng-Tjhen

    2018-02-01

    Considerations of nonlocal elasticity and surface effects in micro- and nanoscale beams are both important for the accurate prediction of natural frequency. In this study, the governing equation of a nonlocal Timoshenko beam with surface effects is established by taking into account three types of boundary conditions: hinged-hinged, clamped-clamped and clamped-hinged ends. For a hinged-hinged beam, an exact and explicit natural frequency equation is obtained. However, for clamped-clamped and clamped-hinged beams, the solutions of corresponding frequency equations must be determined numerically due to their transcendental nature. Hence, the Fredholm integral equation approach coupled with a curve fitting method is employed to derive the approximate fundamental frequency equations, which can predict the frequency values with high accuracy. In short, explicit frequency equations of the Timoshenko beam for three types of boundary conditions are proposed to exhibit directly the dependence of the natural frequency on the nonlocal elasticity, surface elasticity, residual surface stress, shear deformation and rotatory inertia, avoiding the complicated numerical computation.

  15. Accurate frequency and time dissemination in the optical domain

    NASA Astrophysics Data System (ADS)

    Khabarova, K. Yu; Kalganova, E. S.; Kolachevsky, N. N.

    2018-02-01

    The development of the optical frequency comb technique has enabled a wide use of atomic optical clocks by allowing frequency conversion from the optical to the radio frequency range. Today, the fractional instability of such clocks has reached the record eighteen-digit level, two orders of magnitude better than for cesium fountains representing the primary frequency standard. This is paralleled by the development of techniques for transferring accurate time and optical frequency signals, including fiber links. With this technology, the fractional instability of transferred frequency can be lowered to below 10‑18 with an averaging time of 1000 s for a 1000 km optical link. At a distance of 500 km, a time signal uncertainty of 250 ps has been achieved. Optical links allow comparing optical clocks and creating a synchronized time and frequency standard network at a new level of precision. Prospects for solving new problems arise, including the determination of the gravitational potential, the measurement of the continental Sagnac effect, and precise tests of fundamental theories.

  16. Estimating canopy water content from spectroscopy

    USDA-ARS?s Scientific Manuscript database

    Foliar water content is a dynamic quantity depending on water losses from transpiration and water uptake from the soil. Absorption of shortwave radiation by water is determined by various frequency overtones of fundamental bending and stretching molecular transitions. Leaf water potential and rela...

  17. Linguistic Models of FO Use, Physiological Models of FO Control, and the Issue of "Mean Response Time."

    ERIC Educational Resources Information Center

    Herman, Rebecca; Beckman, Mary; Honda, Kiyoshi

    1999-01-01

    Evaluates "mean response time" (MRT), a method used in previous studies to relate physiological evidence (recordings of electromyographic activity in the cricothyroid and sternohyoid) to acoustic evidence (fundamental frequency). (Author/VWL)

  18. Shipboard Electronic Equipments.

    ERIC Educational Resources Information Center

    Naval Personnel Program Support Activity, Washington, DC.

    Fundamentals of major electronic equipments on board ships are presented in this text prepared for naval officers in general. Basic radio principles are discussed in connection with various types of transmitters, receivers, antennas, couplers, transfer panels, remote-control units, frequency standard equipments, teletypewriters, and facsimile…

  19. Perceptual Space of Superimposed Dual-Frequency Vibrations in the Hands.

    PubMed

    Hwang, Inwook; Seo, Jeongil; Choi, Seungmoon

    2017-01-01

    The use of distinguishable complex vibrations that have multiple spectral components can improve the transfer of information by vibrotactile interfaces. We investigated the qualitative characteristics of dual-frequency vibrations as the simplest complex vibrations compared to single-frequency vibrations. Two psychophysical experiments were conducted to elucidate the perceptual characteristics of these vibrations by measuring the perceptual distances among single-frequency and dual-frequency vibrations. The perceptual distances of dual-frequency vibrations between their two frequency components along their relative intensity ratio were measured in Experiment I. The estimated perceptual spaces for three frequency conditions showed non-linear perceptual differences between the dual-frequency and single-frequency vibrations. A perceptual space was estimated from the measured perceptual distances among ten dual-frequency compositions and five single-frequency vibrations in Experiment II. The effect of the component frequency and the frequency ratio was revealed in the perceptual space. In a percept of dual-frequency vibration, the lower frequency component showed a dominant effect. Additionally, the perceptual difference among single-frequency and dual-frequency vibrations were increased with a low relative difference between two frequencies of a dual-frequency vibration. These results are expected to provide a fundamental understanding about the perception of complex vibrations to enrich the transfer of information using vibrotactile stimuli.

  20. Simulation studies of plasma waves in the electron foreshock - The generation of downshifted oscillations

    NASA Technical Reports Server (NTRS)

    Dum, C. T.

    1990-01-01

    The generation of waves with frequencies downshifted from the plasma frequency, as observed in the electron foreshock, is analyzed by particle simulation. Wave excitation differs fundamentally from the familiar excitation of the plasma eigenmodes by a gentle bump-on-tail electron distribution. Beam modes are destabilized by resonant interaction with bulk electrons, provided the beam velocity spread is very small. These modes are stabilized, starting with the higher frequencies, as the beam is broadened and slowed down by the interaction with the wave spectrum. Initially a very cold beam is also capable of exciting frequencies considerably above the plasma frequency, but such oscillations are quickly stabilized. Low-frequency modes persist for a long time, until the bump in the electron distribution is completely 'ironed' out. This diffusion process also is quite different from the familiar case of well-separated beam and bulk electrons. A quantitative analysis of these processes is carried out.

  1. Low-frequency oscillations in Hall thrusters

    NASA Astrophysics Data System (ADS)

    Wei, Li-Qiu; Han, Liang; Yu, Da-Ren; Guo, Ning

    2015-05-01

    In this paper, we summarize the research development of low-frequency oscillations in the last few decades. The findings of physical mechanism, characteristics and stabilizing methods of low-frequency oscillations are discussed. It shows that it is unreasonable and incomplete to model an ionization region separately to analyze the physical mechanism of low-frequency oscillations. Electro-dynamics as well as the formation conditions of ionization distribution play an important role in characteristics and stabilizing of low-frequency oscillations. Understanding the physical mechanism and characteristics of low- frequency oscillations thoroughly and developing a feasible method stabilizing this instability are still important research subjects. Project supported by the National Natural Science Foundation of China (Grant No. 51477035), the Fundamental Research Funds for the Central Universities, China (Grant No. HIT.NSRIF 2015064), and the Open Research Fund Program of State Key Laboratory of Cryogenic Vacuum Technology and Physics, China (Grant No. ZDK201304).

  2. Formant characteristics of human laughter.

    PubMed

    Szameitat, Diana P; Darwin, Chris J; Szameitat, André J; Wildgruber, Dirk; Alter, Kai

    2011-01-01

    Although laughter is an important aspect of nonverbal vocalization, its acoustic properties are still not fully understood. Extreme articulation during laughter production, such as wide jaw opening, suggests that laughter can have very high first formant (F(1)) frequencies. We measured fundamental frequency and formant frequencies of the vowels produced in the vocalic segments of laughter. Vocalic segments showed higher average F(1) frequencies than those previously reported and individual values could be as high as 1100 Hz for male speakers and 1500 Hz for female speakers. To our knowledge, these are the highest F(1) frequencies reported to date for human vocalizations, exceeding even the F(1) frequencies reported for trained soprano singers. These exceptionally high F(1) values are likely to be based on the extreme positions adopted by the vocal tract during laughter in combination with physiological constraints accompanying the production of a "pressed" voice. Copyright © 2011 The Voice Foundation. All rights reserved.

  3. Gigahertz flexible graphene transistors for microwave integrated circuits.

    PubMed

    Yeh, Chao-Hui; Lain, Yi-Wei; Chiu, Yu-Chiao; Liao, Chen-Hung; Moyano, David Ricardo; Hsu, Shawn S H; Chiu, Po-Wen

    2014-08-26

    Flexible integrated circuits with complex functionalities are the missing link for the active development of wearable electronic devices. Here, we report a scalable approach to fabricate self-aligned graphene microwave transistors for the implementation of flexible low-noise amplifiers and frequency mixers, two fundamental building blocks of a wireless communication receiver. A devised AlOx T-gate structure is used to achieve an appreciable increase of device transconductance and a commensurate reduction of the associated parasitic resistance, thus yielding a remarkable extrinsic cutoff frequency of 32 GHz and a maximum oscillation frequency of 20 GHz; in both cases the operation frequency is an order of magnitude higher than previously reported. The two frequencies work at 22 and 13 GHz even when subjected to a strain of 2.5%. The gigahertz microwave integrated circuits demonstrated here pave the way for applications which require high flexibility and radio frequency operations.

  4. Measurement of attenuation coefficients of the fundamental and second harmonic waves in water

    NASA Astrophysics Data System (ADS)

    Zhang, Shuzeng; Jeong, Hyunjo; Cho, Sungjong; Li, Xiongbing

    2016-02-01

    Attenuation corrections in nonlinear acoustics play an important role in the study of nonlinear fluids, biomedical imaging, or solid material characterization. The measurement of attenuation coefficients in a nonlinear regime is not easy because they depend on the source pressure and requires accurate diffraction corrections. In this work, the attenuation coefficients of the fundamental and second harmonic waves which come from the absorption of water are measured in nonlinear ultrasonic experiments. Based on the quasilinear theory of the KZK equation, the nonlinear sound field equations are derived and the diffraction correction terms are extracted. The measured sound pressure amplitudes are adjusted first for diffraction corrections in order to reduce the impact on the measurement of attenuation coefficients from diffractions. The attenuation coefficients of the fundamental and second harmonics are calculated precisely from a nonlinear least squares curve-fitting process of the experiment data. The results show that attenuation coefficients in a nonlinear condition depend on both frequency and source pressure, which are much different from a linear regime. In a relatively lower drive pressure, the attenuation coefficients increase linearly with frequency. However, they present the characteristic of nonlinear growth in a high drive pressure. As the diffraction corrections are obtained based on the quasilinear theory, it is important to use an appropriate source pressure for accurate attenuation measurements.

  5. What is the temporal analog of reflection and refraction of optical beams?

    DOE PAGES

    Plansinis, B. W.; Donaldson, W. R.; Agrawal, G. P.

    2015-10-28

    It is shown numerically and analytically that when an optical pulse approaches a moving temporal boundary across which the refractive index changes, it undergoes a temporal equivalent of reflection and refraction of optical beams at a spatial boundary. The main difference is that the role of angles is played by changes in the frequency. The frequency dependence of the dispersion of the material in which the pulse is propagating plays a fundamental role in determining the frequency shifts experienced by the reflected and refracted pulses. As a result, our analytic expressions for these frequency shifts allow us to find themore » condition under which an analog of total internal reflection may occur at the temporal boundary.« less

  6. Reusable EGaIn-Injected Substrate-Integrated-Waveguide Resonator for Wireless Sensor Applications

    PubMed Central

    Memon, Muhammad Usman; Lim, Sungjoon

    2015-01-01

    The proposed structure in this research is constructed on substrate integrated waveguide (SIW) technology and has a mechanism that produces 16 different and distinct resonant frequencies between 2.45 and 3.05 GHz by perturbing a fundamental TE10 mode. It is a unique method for producing multiple resonances in a radio frequency planar structure without any extra circuitry or passive elements is developed. The proposed SIW structure has four vertical fluidic holes (channels); injecting eutectic gallium indium (EGaIn), also known commonly as liquid metal (LM), into these vertical channels produces different resonant frequencies. Either a channel is empty, or it is filled with LM. In total, the combination of different frequencies produced from four vertical channels is 16. PMID:26569257

  7. Structural parameters that influence the noise reduction characteristics of typical general aviation materials

    NASA Technical Reports Server (NTRS)

    Roskam, J.; Grosveld, F.

    1980-01-01

    Effect of panel curvature and oblique angle of sound incidence on noise reduction characteristics of an aluminum panel are experimentally investigated. Panel curvature results show significant increase in stiffness with comparable decrease of sound transmission through the panel in the frequency region below the panel/cavity resonance frequency. Noise reduction data have been achieved for aluminum panels with clamped, bonded and riveted edge conditions. These edge conditions are shown to influence noise reduction characteristics of aluminum panels. Experimentally measured noise reduction characteristics of flat aluminum panels with uniaxial and biaxial in-plane stresses are presented and discussed. Results indicate important improvement in noise reduction of these panels in the frequency range below the fundamental panel/cavity resonance frequency.

  8. Buoyancy Waves in Earth's Magnetosphere: Calculations for a 2-D Wedge Magnetosphere

    NASA Astrophysics Data System (ADS)

    Wolf, R. A.; Toffoletto, F. R.; Schutza, A. M.; Yang, J.

    2018-05-01

    To improve theoretical understanding of the braking oscillations observed in Earth's inner plasma sheet, we have derived a theoretical model that describes k∥ = 0 magnetohydrodynamic waves in an idealized magnetospheric configuration that consists of a 2-D wedge with circular-arc field lines. The low-frequency, short-perpendicular-wavelength mode obeys a differential equation that is often used to describe buoyancy oscillations in a neutral atmosphere, so we call those waves "buoyancy waves," though the magnetospheric buoyancy force results from magnetic tension rather than gravity. Propagation of the wave is governed mainly by a position-dependent frequency ωb, the "buoyancy frequency," which is a fundamental property of the magnetosphere. The waves propagate if ωb > ω but otherwise evanesce. In the wedge magnetosphere, ωb turns out to be exactly the fundamental oscillation frequency for poloidal oscillations of a thin magnetic filament, and we assume that the same is true for the real magnetosphere. Observable properties of buoyancy oscillations are discussed, but propagation characteristics vary considerably with the state of the magnetosphere. For a given event, the buoyancy frequency and propagation characteristics can be determined from pressure and density profiles and a magnetic field model, and these characteristics have been worked out for one typical configuration. A localized disturbance that initially resembles a dipolarizing flux bundle spreads east-west and also penetrates into the plasmasphere to some extent. The calculated amplitude near the center of the original wave packet decays in a few oscillation periods, even though our calculation includes no dissipation.

  9. Microwave power amplifiers based on AlGaN/GaN transistors with a two-dimensional electron gas

    NASA Astrophysics Data System (ADS)

    Vendik, O. G.; Vendik, I. B.; Tural'chuk, P. A.; Parnes, Ya. M.; Parnes, M. D.

    2016-11-01

    A technique for synthesis of microwave power amplifiers based on transistors with a AlGaN/GaN heterojunction is discussed. Special focus is on the development of a technique for synthesis of transformation circuits of the power amplifier to increase efficiency with a retained high output power. The use of independent matching at the harmonic frequencies and fundamental frequency makes it possible to control the attainable efficiency in a wide frequency band along with the total suppression of harmonics beyond the operational band. Microwave power amplifiers for operation at 4 and 9 GHz have been developed and experimentally investigated.

  10. Quantum synchronization of a driven self-sustained oscillator.

    PubMed

    Walter, Stefan; Nunnenkamp, Andreas; Bruder, Christoph

    2014-03-07

    Synchronization is a universal phenomenon that is important both in fundamental studies and in technical applications. Here we investigate synchronization in the simplest quantum-mechanical scenario possible, i.e., a quantum-mechanical self-sustained oscillator coupled to an external harmonic drive. Using the power spectrum we analyze synchronization in terms of frequency entrainment and frequency locking in close analogy to the classical case. We show that there is a steplike crossover to a synchronized state as a function of the driving strength. In contrast to the classical case, there is a finite threshold value in driving. Quantum noise reduces the synchronized region and leads to a deviation from strict frequency locking.

  11. Anomalous nonlinear absorption in epsilon-near-zero materials: optical limiting and all-optical control.

    PubMed

    Vincenti, M A; de Ceglia, D; Scalora, Michael

    2016-08-01

    We investigate nonlinear absorption in films of epsilon-near-zero materials. The combination of large local electric fields at the fundamental frequency and material losses at the harmonic frequencies induce unusual intensity-dependent phenomena. We predict that the second-order nonlinearity of a low-damping, epsilon-near-zero slab produces an optical limiting effect that mimics a two-photon absorption process. Anomalous absorption profiles that depend on low permittivity values at the pump frequency are also predicted for third-order nonlinearities. These findings suggest new opportunities for all-optical light control and novel ways to design reconfigurable and tunable nonlinear devices.

  12. The resonant body transistor.

    PubMed

    Weinstein, Dana; Bhave, Sunil A

    2010-04-14

    This paper introduces the resonant body transistor (RBT), a silicon-based dielectrically transduced nanoelectromechanical (NEM) resonator embedding a sense transistor directly into the resonator body. Combining the benefits of FET sensing with the frequency scaling capabilities and high quality factors (Q) of internal dielectrically transduced bar resonators, the resonant body transistor achieves >10 GHz frequencies and can be integrated into a standard CMOS process for on-chip clock generation, high-Q microwave circuits, fundamental quantum-state preparation and observation, and high-sensitivity measurements. An 11.7 GHz bulk-mode RBT is demonstrated with a quality factor Q of 1830, marking the highest frequency acoustic resonance measured to date on a silicon wafer.

  13. Polycrystalline diamond RF MOSFET with MoO3 gate dielectric

    NASA Astrophysics Data System (ADS)

    Ren, Zeyang; Zhang, Jinfeng; Zhang, Jincheng; Zhang, Chunfu; Chen, Dazheng; Quan, Rudai; Yang, Jiayin; Lin, Zhiyu; Hao, Yue

    2017-12-01

    We report the radio frequency characteristics of the diamond metal-oxide-semiconductor field effect transistor with MoO3 gate dielectric for the first time. The device with 2-μm gate length was fabricated on high quality polycrystalline diamond. The maximum drain current of 150 mA/mm at VGS = -5 V and the maximum transconductance of 27 mS/mm were achieved. The extrinsic cutoff frequency of 1.2 GHz and the maximum oscillation frequency of 1.9 GHz have been measured. The moderate frequency characteristics are attributed to the moderate transconductance limited by the series resistance along the channel. We expect that the frequency characteristics of the device can be improved by increasing the magnitude of gm, or fundamentally decreasing the gate-controlled channel resistance and series resistance along the channel, and down-scaling the gate length.

  14. Statistical characteristics of MST radar echoes and its interpretation

    NASA Technical Reports Server (NTRS)

    Woodman, Ronald F.

    1989-01-01

    Two concepts of fundamental importance are reviewed: the autocorrelation function and the frequency power spectrum. In addition, some turbulence concepts, the relationship between radar signals and atmospheric medium statistics, partial reflection, and the characteristics of noise and clutter interference are discussed.

  15. 47 CFR 15.31 - Measurement standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the installation site, such as perimeter protection systems, carrier current systems, and systems... variation of the input power or the radiated signal level of the fundamental frequency component of the... nominal rated supply voltage. For battery operated equipment, the equipment tests shall be performed using...

  16. Ocean Magnetics: 1. Fundamental Survey and Estimates of Induction Phenomena

    DTIC Science & Technology

    1977-10-01

    sensitivities of /i0-• /Hz only in the far infra - sonic regime. We may note that, for a noise souce at great distances (R) such that its radiation...Various Ocean Depths (D), Pycnocline Depths (d), and Density Changes (6p/p), Sonic Mode (0), with IW Truncated at Brunt-Vaisala Frequency for aJ 25-m...Changes (6p/p), Sonic Mode MQ, with 1WI ~Truncated at Brunt Vaisala Frequency for a 25-rn-Thick Pycnocline.I Dashed line separates quasi-static (left

  17. Cross-phase-modulation-induced instability in photonic-crystal fibers.

    PubMed

    Serebryannikov, E E; Konorov, S O; Ivanov, A A; Alfimov, M V; Scalora, M; Zheltikov, A M

    2005-08-01

    Cross-phase-modulation-induced instability is identified as a significant mechanism for efficient parametric four-wave-mixing frequency conversion in photonic-crystal fibers. Fundamental-wavelength femtosecond pulses of a Cr, forsterite laser are used in our experiments to transform the spectrum of copropagating second-harmonic pulses of the same laser in a photonic-crystal fiber. Efficient generation of sidebands shifted by more than 80 THz with respect to the central frequency of the second harmonic is observed in the output spectrum of the probe field.

  18. Controlling the carrier-envelope phase of Raman-generated periodic waveforms.

    PubMed

    Hsieh, Zhi-Ming; Lai, Chien-Jen; Chan, Han-Sung; Wu, Sih-Ying; Lee, Chao-Kuei; Chen, Wei-Jan; Pan, Ci-Ling; Yee, Fu-Goul; Kung, A H

    2009-05-29

    We demonstrate control of the carrier-envelope phase of ultrashort periodic waveforms that are synthesized from a Raman-generated optical frequency comb. We generated the comb by adiabatically driving a molecular vibrational coherence with a beam at a fundamental frequency plus its second harmonic. Heterodyne measurements show that full interpulse phase locking of the comb components is realized. The results set the stage for the synthesis of periodic arbitrary waveforms in the femtosecond and subfemtosecond regimes with full control.

  19. Continuous-wave laser at 440 nm based on frequency-doubled diode-pumped Nd:GdVO(4) crystal.

    PubMed

    Castaing, Marc; Balembois, François; Georges, Patrick

    2008-09-01

    We present for the first time, to the best of our knowledge, a frequency-doubled Nd:GdVO(4) laser operating in a cw on the pure three-level laser line at 880 nm. We obtained 300 mW at 440 nm for 23 W of incident pump power at 808 nm. Moreover, with a 25% output coupler we obtained a cw power of 1.9 W at the fundamental wavelength at 880 nm.

  20. Elastic Nonlinear Response in Granular Media Under Resonance Conditions

    NASA Astrophysics Data System (ADS)

    Jia, X.; Johnson, P. A.

    2004-12-01

    We are studying the elastic linear and nonlinear behavior of granular media using dynamic wave methods. In the work presented here, our goal is to quantify the elastic nonlinear response by applying wave resonance. Resonance studies are desirable because they provide the means to easily study amplitude dependencies of elastic nonlinear behavior and thus to characterize the physical nature of the elastic nonlinearity. This work has implications for a variety of topics, in particular, the in situ nonlinear response of surface sediments. For this work we constructed an experimental cell in which high sensitivity dynamic resonance studies were conducted using granular media under controlled effective pressure. We limit our studies here to bulk modes but have the capability to employ shear waves as well. The granular media are composed of glass beads held under pressure by a piston, while applying resonance waves from transducers as both the excitation and the material probe. The container is closed with two fitted pistons and a normal load is applied to the granular sample across the top piston. Force and displacement are measured directly. Resonant frequency sweeps with frequencies corresponding to the fundamental bulk mode are applied to the longitudinal source transducer. The pore pressure in the system is 1 atm. The glass beads used in our experiments are of diameter 0.5 mm, randomly deposited in a duralumin cylinder of diameter 30 mm and height of 15 mm. This corresponds to a granular skeleton acoustic wave velocity of v ª 750m/s under 50 N of force [0.07 Mpa]. The loaded system gives fundamental mode resonances in the audio frequency band at half a wavelength where resonance frequency is effective-pressure dependent. The volume fraction of glass beads thus obtained is found to be 0.63 ± 0.01. Plane-wave generating and detecting transducers of diameter 30 mm are placed on axis at the top and bottom of the cylindrical container in direct contact with the glass beads. The wave signals are detected using a lock-in amplifier, and frequency and amplitude are recorded on computer. Drive frequency is swept from below to above the resonance mode. A typical frequency sweep is 3 kHz in width with a frequency sampling of 6 Hz. Frequency sweeps are applied at progressively increasing drive voltages to test for nonlinear-dynamical induced modulus softening. The resonance frequency at peak amplitude corresponds directly to modulus. We find significant elastic nonlinearity at all effective pressures, manifest by the fundamental-mode resonance curves decreasing progressively, at progressively increasing drive level. This is equivalent to progressive material softening with wave amplitude, meaning the wavespeed and modulus diminish. The wave dissipation simultaneously increases (Johnson and Sutin 2004). For example, at 0.11 Mpa effective pressure the observed change in resonance frequency of about 2.6% corresponds to a material bulk modulus decrease of about 5.2%. Strain amplitudes are 10-7-10-6. Thus, we would predict that surface sediments should have significant elastic nonlinear response beginning at about 10-6 strain amplitude. reference: Johnson, P. and A. Sutin, Slow dynamics in diverse solids, J. Acoust. Soc Am., in press (2004).

  1. A comparison of speech intonation production and perception abilities of Farsi speaking cochlear implanted and normal hearing children.

    PubMed

    Moein, Narges; Khoddami, Seyyedeh Maryam; Shahbodaghi, Mohammad Rahim

    2017-10-01

    Cochlear implant prosthesis facilitates spoken language development and speech comprehension in children with severe-profound hearing loss. However, this prosthesis is limited in encoding information about fundamental frequency and pitch that are essentially for recognition of speech prosody. The purpose of the present study is to investigate the perception and production of intonation in cochlear implant children and comparison with normal hearing children. This study carried out on 25 cochlear implanted children and 50 children with normal hearing. First, using 10 action pictures statements and questions sentences were extracted. Fundamental frequency and pitch changes were identified using Praat software. Then, these sentences were judged by 7 adult listeners. In second stage 20 sentences were played for child and he/she determined whether it was in a question form or statement one. Performance of cochlear implanted children in perception and production of intonation was significantly lower than children with normal hearing. The difference between fundamental frequency and pitch changes in cochlear implanted children and children with normal hearing was significant (P < 0/05). Cochlear implanted children performance in perception and production of intonation has significant correlation with child's age surgery and duration of prosthesis use (P < 0/05). The findings of the current study show that cochlear prostheses have limited application in facilitating the perception and production of intonation in cochlear implanted children. It should be noted that the child's age at the surgery and duration of prosthesis's use is important in reduction of this limitation. According to these findings, speech and language pathologists should consider intervention of intonation in treatment program of cochlear implanted children. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Effects of Weight Loss on Acoustic Parameters After Bariatric Surgery.

    PubMed

    de Souza, Lourdes Bernadete Rocha; Dos Santos, Marquiony Marques; Pernambuco, Leandro Araújo; de Almeida Godoy, Cynthia Meira; da Silva Lima, Deysianne Meire

    2018-05-01

    Patients with morbid obesity may present vocal alterations, since large accumulation of fat in the vocal tract may interfere with voice production of these individuals. Verify the neck circumference and the acoustic parameters of voice in obese women, before and after the bariatric surgery, and compare the results with a control group, with normal weight. Observational, longitudinal, descriptive study with patients referred to the SCODE (Obesity Surgery and Related Disorders Center) in a university hospital. The sample consisted of 25 morbidly obese women, age range 28-43 years and 23 non-obese women, aged 21-41 years control group. To measure the neck circumference, a tape measure was used and all participants were seated upright with the head positioned in the Frankfort horizontal plane. The fundamental frequency was calculated through the sustained emission of vowel [a] at usual intensity and pitch, to measure the fundamental frequency of the voice, that is, how much the vocal fold vibrates per second. After the recording, participants were prompted to produce vowels [a], [i], and [u] sustained at usual intensity and pitch, and a stopwatch was used to measure the maximum phonation time, to verify the balance between myoelastic and dynamic forces of the larynx. After 8 months post-surgery, the patients were recruited to be re-evaluated using the same pre-surgical data collection procedures. There was an increase in the mean value of f0. The maximum phonation time of all vowels increased after surgery. Obese individuals with post-surgery weight loss may present neck circumference, fundamental frequency, and maximum phonation time values closer to the mean values of normal weight individuals. In this study, weight loss was sufficient to adjust the acoustic parameter measurements.

  3. Reliable jitter and shimmer measurements in voice clinics: the relevance of vowel, gender, vocal intensity, and fundamental frequency effects in a typical clinical task.

    PubMed

    Brockmann, Meike; Drinnan, Michael J; Storck, Claudio; Carding, Paul N

    2011-01-01

    The aims of this study were to examine vowel and gender effects on jitter and shimmer in a typical clinical voice task while correcting for the confounding effects of voice sound pressure level (SPL) and fundamental frequency (F(0)). Furthermore the relative effect sizes of vowel, gender, voice SPL, and F(0) were assessed, and recommendations for clinical measurements were derived. With this cross-sectional single cohort study, 57 healthy adults (28 women, 29 men) aged 20-40 years were investigated. Three phonations of /a/, /o/, and /i/ at "normal" voice loudness were analyzed using Praat (software). The effects of vowel, gender, voice SPL, and F(0) on jitter and shimmer were assessed using descriptive and inferential (analysis of covariance) statistics. The effect sizes were determined with the eta-squared statistic. Vowels, gender, voice SPL, and F(0), each had significant effects either on jitter or on shimmer, or both. Voice SPL was the most important factor, whereas vowel, gender, and F(0) effects were comparatively small. Because men had systematically higher voice SPL, the gender effects on jitter and shimmer were smaller when correcting for SPL and F(0). Surprisingly, in clinical assessments, voice SPL has the single biggest impact on jitter and shimmer. Vowel and gender effects were clinically important, whereas fundamental frequency had a relatively small influence. Phonations at a predefined voice SPL (80 dB minimum) and vowel (/a/) would enhance measurement reliability. Furthermore, gender-specific thresholds applying these guidelines should be established. However, the efficiency of these measures should be verified and tested with patients. Copyright © 2011 The Voice Foundation. All rights reserved.

  4. Low Frequency Radioastronomy at Moon: possible approach and architecture

    NASA Astrophysics Data System (ADS)

    Skalsky, A.; Mogilevsky, M.; Nazarov, V.; Nazirov, R.; Batanov, O.; Sadovski, A.

    2009-04-01

    The Moon, the Earth's neighbor, attracts an attention as a celestial body, as a source for mineral and other resources and as a possible base for fundamental scientific researches. The conducting ionosphere of Earth completely shields radioemissions coming from outer space and propagating at frequencies below a few MHz. In contrary, the Moon possessing a week atmosphereionosphere around its surface seems to be a perfect base for carrying out measurements of low frequency radio emissions originated from the space. The radio facility deployed at Moon's surface seems to be a powerful tool for various fundamental space researches related to astrophysics, solar system and magnetospheric investigations. The most intriguing objective is a search of terrestrial-like planets in the exosolar system, i.e. planets possessing the intrinsic magnetic fields and developed magnetospheres which interaction with the star wind results in generation of radioemissions (similar to AKR radiation of the terrestrial magnetosphere). Creating the infrastructure of antennas (sensors) on Moon's surface is planned for reaching the described goals. Ideology of such infrastructure (which may be treated as macro-instrument) is closely to SensorWeb approach. The different sensors are collected to unified platforms (PODs in terms of SensorWeb) which provide omni-and bidirectional information flows between PODs. Thus a set of sensors is integrated self-organizing amorphous organism on the base of wireless network. It increases reliability of the research complex and allows quick reconfiguring and adopting it for different investigation tasks. For additional redundancy and openness of the complex at least some PODs will support not only inter-PODs protocol but IEEE 802.16 Wireless LAN standard used in NASA Lunar Communication and Navigation Architecture also. The paper presents a possible approach to the development of the radio facility deployed at Moon's surface, its implementation for various fundamental researches

  5. Mobile Communication Devices, Ambient Noise, and Acoustic Voice Measures.

    PubMed

    Maryn, Youri; Ysenbaert, Femke; Zarowski, Andrzej; Vanspauwen, Robby

    2017-03-01

    The ability to move with mobile communication devices (MCDs; ie, smartphones and tablet computers) may induce differences in microphone-to-mouth positioning and use in noise-packed environments, and thus influence reliability of acoustic voice measurements. This study investigated differences in various acoustic voice measures between six recording equipments in backgrounds with low and increasing noise levels. One chain of continuous speech and sustained vowel from 50 subjects with voice disorders (all separated by silence intervals) was radiated and re-recorded in an anechoic chamber with five MCDs and one high-quality recording system. These recordings were acquired in one condition without ambient noise and in four conditions with increased ambient noise. A total of 10 acoustic voice markers were obtained in the program Praat. Differences between MCDs and noise condition were assessed with Friedman repeated-measures test and posthoc Wilcoxon signed-rank tests, both for related samples, after Bonferroni correction. (1) Except median fundamental frequency and seven nonsignificant differences, MCD samples have significantly higher acoustic markers than clinical reference samples in minimal environmental noise. (2) Except median fundamental frequency, jitter local, and jitter rap, all acoustic measures on samples recorded with the reference system experienced significant influence from room noise levels. Fundamental frequency is resistant to recording system, environmental noise, and their combination. All other measures, however, were impacted by both recording system and noise condition, and especially by their combination, often already in the reference/baseline condition without added ambient noise. Caution is therefore warranted regarding implementation of MCDs as clinical recording tools, particularly when applied for treatment outcomes assessments. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  6. Vocal Behavior in Environmental Noise: Comparisons Between Work and Leisure Conditions in Women With Work-related Voice Disorders and Matched Controls.

    PubMed

    Szabo Portela, Annika; Granqvist, Svante; Ternström, Sten; Södersten, Maria

    2018-01-01

    This study aimed to assess vocal behavior in women with voice-intensive occupations to investigate differences between patients and controls and between work and leisure conditions with environmental noise level as an experimental factor. Patients with work-related voice disorders, 10 with phonasthenia and 10 with vocal nodules, were matched regarding age, profession, and workplace with 20 vocally healthy colleagues. The sound pressure level of environmental noise and the speakers' voice, fundamental frequency, and phonation ratio were registered from morning to night during 1 week with a voice accumulator. Voice data were assessed in low (≤55 dBA), moderate, and high (>70 dBA) environmental noise levels. The average environmental noise level was significantly higher during the work condition for patients with vocal nodules (73.9 dBA) and their controls (73.0 dBA) compared with patients with phonasthenia (68.3 dBA) and their controls (67.1 dBA). The average voice level and the fundamental frequency were also significantly higher during work for the patients with vocal nodules and their controls. During the leisure condition, there were no significant differences in average noise and voice level nor fundamental frequency between the groups. The patients with vocal nodules and their controls spent significantly more time and used their voices significantly more in high-environmental noise levels. High noise levels during work and demands from the occupation impact vocal behavior. Thus, assessment of voice ergonomics should be part of the work environmental management. To reduce environmental noise levels is important to improve voice ergonomic conditions in communication-intensive and vocally demanding workplaces. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  7. Fundamental frequency characteristics of Jordanian Arabic speakers.

    PubMed

    Natour, Yaser S; Wingate, Judith M

    2009-09-01

    This study is the first in a series of investigations designed to test the acoustic characteristics of the normal Arabic voice. The subjects were three hundred normal Jordanian Arabic speakers (100 adult males, 100 adult females, and 100 children). The subjects produced a sustained phonation of the vowel /a:/ and stated their complete names (i.e. first, second, third and surname) using a carrier phrase. The samples were analyzed using the Multi Dimensional Voice Program (MDVP). Fundamental frequency (F0) from the /a:/ and speaking fundamental frequency (SF0) from the sentence were analyzed. Results revealed a significant difference of both F0 and SF0 values among adult Jordanian Arabic-speaking males (F0=131.34Hz +/- 18.65, SF0=137.45 +/- 18.93), females (F0=231.13Hz +/- 20.86, SF0=230.84 +/- 16.50) and children (F0=270.93Hz +/- 20.01, SF0=278.04 +/- 32.07). Comparison with other ethnicities indicated that F0 values of adult Jordanian Arabic-speaking males and females are generally consistent with adult Caucasian and African-American values. However, for Jordanian Arabic-speaking children, a higher trend in F0 values was present than their Western counterparts. SF0 values for adult Jordanian Arabic-speaking males are generally consistent with the adult Caucasian male SF0 values. However, SF0 values of adult Jordanian-speaking females and children were relatively higher than the reported Western values. It is recommended that speech-language pathologists in Arabic-speaking countries, Jordan in specific, utilize the new data provided (F0 and SF0) when evaluating and/or treating Arabic-speaking patients. Due to its cross-linguistic variability, SF0 emerged as a preferred measurement when conducting cross-cultural comparisons of voice features.

  8. Fundamental deficits of auditory perception in Wernicke's aphasia.

    PubMed

    Robson, Holly; Grube, Manon; Lambon Ralph, Matthew A; Griffiths, Timothy D; Sage, Karen

    2013-01-01

    This work investigates the nature of the comprehension impairment in Wernicke's aphasia (WA), by examining the relationship between deficits in auditory processing of fundamental, non-verbal acoustic stimuli and auditory comprehension. WA, a condition resulting in severely disrupted auditory comprehension, primarily occurs following a cerebrovascular accident (CVA) to the left temporo-parietal cortex. Whilst damage to posterior superior temporal areas is associated with auditory linguistic comprehension impairments, functional-imaging indicates that these areas may not be specific to speech processing but part of a network for generic auditory analysis. We examined analysis of basic acoustic stimuli in WA participants (n = 10) using auditory stimuli reflective of theories of cortical auditory processing and of speech cues. Auditory spectral, temporal and spectro-temporal analysis was assessed using pure-tone frequency discrimination, frequency modulation (FM) detection and the detection of dynamic modulation (DM) in "moving ripple" stimuli. All tasks used criterion-free, adaptive measures of threshold to ensure reliable results at the individual level. Participants with WA showed normal frequency discrimination but significant impairments in FM and DM detection, relative to age- and hearing-matched controls at the group level (n = 10). At the individual level, there was considerable variation in performance, and thresholds for both FM and DM detection correlated significantly with auditory comprehension abilities in the WA participants. These results demonstrate the co-occurrence of a deficit in fundamental auditory processing of temporal and spectro-temporal non-verbal stimuli in WA, which may have a causal contribution to the auditory language comprehension impairment. Results are discussed in the context of traditional neuropsychology and current models of cortical auditory processing. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Noise elimination method using a transmission line for the diagnostics of radio frequency plasma

    NASA Astrophysics Data System (ADS)

    Shimizu, K.; Hallil, A.; Amemiya, H.

    1997-04-01

    A filter using a transmission line formed by a cascade connection of inverted L-type networks has been developed to reject the distortion of the probe characteristics by rf (radio-frequency) noise. Each inverse L network consists of two coaxial cables with the same physical constant and length. The filter can remove discrete frequency components including the fundamental and harmonic components, the cut-off frequencies being determined by the distributed circuit constant and the length of the cables. By inserting different kinds of the network in cascade, many noise components associated with the rf frequency can be eliminated at the end section of the filter. Experiments have been performed in rf plasmas by inserting three kinds of inverted L networks with the frequency f (13.56 MHz), 2 f and 4f as the cut-off frequency. Distortion free probe characteristics have been obtained, from which accurate determination of plasma parameter such as the electron energy distribution is possible.

  10. Fundamentals of Zoological Scaling.

    ERIC Educational Resources Information Center

    Lin, Herbert

    1982-01-01

    The following animal characteristics are considered to determine how properties and characteristics of various systems change with system size (scaling): skeletal weight, speed of running, height and range of jumping, food consumption, heart rate, lifetime, locomotive efficiency, frequency of wing-flapping, and maximum sizes of flying and hovering…

  11. 75 FR 62476 - Ultra-Wideband Transmission Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... would be obtained from measurements taken with the system operating in its normal operating mode. At the... with the transmitter operating continuously at a fundamental transmission frequency. 9. Subsequent to... systems, measured in their normal operating modes, is less than that of a UWB transmitter employing...

  12. Broadening of the R(0) and P(2) Lines in the 13CO Fundamental by Helium Atoms from 300 K down to 12 K: Measurements and Comparison with Close-Coupling Calculations

    NASA Technical Reports Server (NTRS)

    Thibault, F.; Mantz, A. W.; Claveau, C.; Valentin, A.; Hurtmans, D.

    2007-01-01

    We present measurements of He-broadening parameters for the R(0) and O(2) lines in the fundamental band of 13CO at different temperatures between 12K and room temperature. The broadening parameters are determined, taking into account confinement narrowing, by simultaneous least-squares fitting of spectra recorded using a frequency stabilized diode laser spectrometer. The pressure broadening cross sections are deduced and compared to close-coupling calculations and earlier results obtained for rotational transitions of 12 CO.

  13. 3D simulation of an audible ultrasonic electrolarynx using difference waves.

    PubMed

    Mills, Patrick; Zara, Jason

    2014-01-01

    A total laryngectomy removes the vocal folds which are fundamental in forming voiced sounds that make speech possible. Although implanted prosthetics are commonly used in developed countries, simple handheld vibrating electrolarynxes are still common worldwide. These devices are easy to use but suffer from many drawbacks including dedication of a hand, mechanical sounding voice, and sound leakage. To address some of these drawbacks, we introduce a novel electrolarynx that uses vibro-acoustic interference of dual ultrasonic waves to generate an audible fundamental frequency. A 3D simulation of the principles of the device is presented in this paper.

  14. Polarization Dependent Whispering Gallery Modes in Microspheres

    NASA Technical Reports Server (NTRS)

    Adamovsky, Grigory (Inventor); Wrbanek, Susan Y. (Inventor)

    2016-01-01

    A tunable resonant system is provided and includes a microsphere that receives an incident portion of a light beam generated via a light source, the light beam having a fundamental mode, a waveguide medium that transmits the light beam from the light source to the microsphere, and a polarizer disposed in a path of the waveguide between the light source and the microsphere. The incident portion of the light beam creates a fundamental resonance inside the microsphere. A change in a normalized frequency of the wavelength creates a secondary mode in the waveguide and the secondary mode creates a secondary resonance inside the microsphere.

  15. High-speed imaging of vocal fold vibrations and larynx movements within vocalizations of different vowels.

    PubMed

    Maurer, D; Hess, M; Gross, M

    1996-12-01

    Theoretic investigations of the "source-filter" model have indicated a pronounced acoustic interaction of glottal source and vocal tract. Empirical investigations of formant pattern variations apart from changes in vowel identity have demonstrated a direct relationship between the fundamental frequency and the patterns. As a consequence of both findings, independence of phonation and articulation may be limited in the speech process. Within the present study, possible interdependence of phonation and phoneme was investigated: vocal fold vibrations and larynx position for vocalizations of different vowels in a healthy man and woman were examined by high-speed light-intensified digital imaging. We found 1) different movements of the vocal folds for vocalizations of different vowel identities within one speaker and at similar fundamental frequency, and 2) constant larynx position within vocalization of one vowel identity, but different positions for vocalizations of different vowel identities. A possible relationship between the vocal fold vibrations and the phoneme is discussed.

  16. Nonlinear Sound Field by Interdigital Transducers in Water

    NASA Astrophysics Data System (ADS)

    Maezawa, Miyuki; Kamada, Rui; Kamakura, Tomoo; Matsuda, Kazuhisa

    2008-05-01

    Nonlinear ultrasound beams in water radiated by a surface acoustic wave (SAW) device are examined experimentally and theoretically. SAWs on an 128° X-cut Y-propagation LiNbO3 substrate are excited by 50 pairs of interdigital transducers (IDTs). The device with a 2 ×10 mm2 rectangular aperture and a center frequency of 20 MHz radiate two ultrasound beams in the direction of the Rayleigh angle determined by the propagation speed of the SAW on the device and of the longitudinal wave in water. The Rayleigh angle becomes 22° in the present experimental situation. The fundamental and second harmonic sound pressures are respectively measured along and across the beam using a miniature hydrophone whose active element 0.4 mm in diameter and whose frequency response is calibrated up to 40 MHz. The Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation is utilized to theoretically predict sound pressure amplitudes. The theoretical predictions of both the fundamental and second harmonic pressures agree well with the measured sound pressures.

  17. Alarm signals of the Sichuan sika deer Cervus nippon sichuanicus.

    PubMed

    Yang, Chengzhong; Xiao, Zhen; Guo, Yanshu; Xiong, Yuanqing; Zhang, Xiuyue; Yue, Bisong

    2012-07-01

    Sichuan sika deer (Cervus nippon sichuanicus) is an endangered and endemic subspecies of sika deer to Sichuan Province, China. According to our observations in the wild, the Sichuan sika deer makes alarm signals in the presence of actual or potential predators. In order to test the variation of the rhythmic alarm calls in some sex/age classes and different risk contexts, we recorded alarm calls of Sichuan sika deer from 2 October to 30 November 2008 and from 4 April to 5 September 2009 in the Tiebu Nature Reserve, Zoige County, Sichuan Province, China, and made acoustic analysis of these alarm calls. The results showed that the fundamental frequencies of alarm signals of Sichuan sika deer tended to decrease with age, and were significantly higher for females than for males. Duration tended to increase with age, and was significantly longer for males than for females. The fundamental frequencies and duration of alarm calls in adults were significantly higher and shorter respectively in high-risk than in moderate-risk contexts.

  18. Experimental Investigations on Effect of Damage on Vibration Characteristics of a Reinforced Concrete Beam

    NASA Astrophysics Data System (ADS)

    Srinivas, V.; Jeyasehar, C. Antony; Ramanjaneyulu, K.; Sasmal, Saptarshi

    2012-02-01

    Need for developing efficient non-destructive damage assessment procedures for civil engineering structures is growing rapidly towards structural health assessment and management of existing structures. Damage assessment of structures by monitoring changes in the dynamic properties or response of the structure has received considerable attention in recent years. In the present study, damage assessment studies have been carried out on a reinforced concrete beam by evaluating the changes in vibration characteristics with the changes in damage levels. Structural damage is introduced by static load applied through a hydraulic jack. After each stage of damage, vibration testing is performed and system parameters were evaluated from the measured acceleration and displacement responses. Reduction in fundamental frequencies in first three modes is observed for different levels of damage. It is found that a consistent decrease in fundamental frequency with increase in damage magnitude is noted. The beam is numerically simulated and found that the vibration characteristics obtained from the measured data are in close agreement with the numerical data.

  19. Arguments for fundamental emission by the parametric process L yields T + S in interplanetary type III bursts. [langmuir, electromagnetic, ion acoustic waves (L, T, S)

    NASA Technical Reports Server (NTRS)

    Cairns, I. H.

    1984-01-01

    Observations of low frequency ion acoustic-like waves associated with Langmuir waves present during interplanetary Type 3 bursts are used to study plasma emission mechanisms and wave processes involving ion acoustic waves. It is shown that the observed wave frequency characteristics are consistent with the processes L yields T + S (where L = Langmuir waves, T = electromagnetic waves, S = ion acoustic waves) and L yields L' + S proceeding. The usual incoherent (random phase) version of the process L yields T + S cannot explain the observed wave production time scale. The clumpy nature of the observed Langmuir waves is vital to the theory of IP Type 3 bursts. The incoherent process L yields T + S may encounter difficulties explaining the observed Type 3 brightness temperatures when Langmuir wave clumps are incorporated into the theory. The parametric process L yields T + S may be the important emission process for the fundamental radiation of interplanetary Type 3 bursts.

  20. Golden Gate Bridge response: a study with low-amplitude data from three earthquakes

    USGS Publications Warehouse

    Çelebi, Mehmet

    2012-01-01

    The dynamic response of the Golden Gate Bridge, located north of San Francisco, CA, has been studied previously using ambient vibration data and finite element models. Since permanent seismic instrumentation was installed in 1993, only small earthquakes that originated at distances varying between ~11 to 122 km have been recorded. Nonetheless, these records prompted this study of the response of the bridge to low amplitude shaking caused by three earthquakes. Compared to previous ambient vibration studies, the earthquake response data reveal a slightly higher fundamental frequency (shorter-period) for vertical vibration of the bridge deck center span (~7.7–8.3 s versus 8.2–10.6 s), and a much higher fundamental frequency (shorter period) for the transverse direction of the deck (~11.24–16.3 s versus ~18.2 s). In this study, it is also shown that these two periods are dominant apparent periods representing interaction between tower, cable, and deck.

Top