2001-04-18
Rocket Naval FUZE PRODUCTION PERCENTAGES BY PRODUCT TYPE * * Based on sales of past 20 Years International Artillery Fuzing Trends • Customer Requirements...Canard Switch www.kdi-ppi.com • Mechanical S&A Design Approach – Modified MK18 S&A • Higher G Loads • AFT Detonation Output • Switches Indicate Rotor
78 FR 31902 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-28
...-557C/B (GBU-31) w/SAASM/AJ 4 JDAM BLU-109 Load Build Trainers 6 MK-82 Filled Inert Bombs 4 BLU-109 Inert Bombs 1312 FMU-152A/B Fuzes (FZU-63 Initiator) 542 GBU-39/B Small Diameter Bombs 530 BLU-109 2000LB Penetrators 780 GBU-12 Bomb 4 GBU-12 Dummy Trainers 154 AIM-9X-2 (Blk II) Tactical Missiles w/DSU...
Weapons Systems, United States Army 1997.
1997-01-01
fewer grenades, a new warhead section fuze and a modified center core burster. The XM85 grenade is equipped with a new self -destruct fuze designed to...Liquid Propellant Gun and an automated loading system. Crusader also requires 3 fewer crewmen than previous self -propelled artillery systems. The new ...market, creating new market opportunities for commercial rotocraft and ensuring the continued supremacy of this technol- ogy that is so critical to
1980-07-01
34 t"Codes LIST OF ILLUSTRATIONS Figure No. Title Page 1 ARRADCOM XM747 ( M739 ) Practice Fuze 2 2A Cover, Spotting Charge 4 2B Cup, Spotting Charge 5 3...Plastic Practice Fuze XM746 Preliminary Design 6 4 Modified PDM739 Fuze 7 5 XM746 All Plastic Fuze 9 6 ARRADCOM XK747 ( M739 ) Practice Fuze 11 7...Assembly 18 11 Smoke Exit Relationship 19 12A XM747 MBA TiCl4 Configuration 23 12B Fuze M739 MOD F 24 13 TiCl4 Assembly 25 14 BKNO3 Assembly 26 15
1993-08-03
44. Name: Fuze PD M739 United Nations Proper Shipping Name: Fuzes, Detonating United Nations Number: 0408 NSN: 1390-00-574-7705 Drawing Number: 9258605...Physical State: Solid United Nations Packing-group: II Amount Per Container: 8 45. Name: Fuze PD M739 United Nations Proper Shipping Name: Fuzes
7. BUILDING 604F, INTERIOR OF BULL PEN SHOWING TESTING STAND ...
7. BUILDING 604-F, INTERIOR OF BULL PEN SHOWING TESTING STAND AND HEAVY WOOD LINING ON CONCRETE WALLS. STEEL PLATE ABOVE TEST STAND DEFLECTS SHRAPNEL, SCREEN FURTHER HELPS TO CONTAIN PARTICLES. ONLY SMALL EXPLOSIVES WERE TESTED HERE (GRENADES, MINES, BOMB FUZES, ETC.). - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ
Special Defense Acquisition Fund (SDAF) Requirement
1982-11-15
the the TOW HEAT Missile and PD Fuses M557 and M739 were diverted every year. f. As a system is set up for collecting and analyzing data, the...684 225 Fuze, MTSQ H278 1506 Fuze# MTSQ 1564 *2000 736 2208 13824 Fuze, PD, M557 90000 3612 50448 4666 Fuze, PD, M739 7233 1252 Fuze, Prox. M514
Air Force Intercontinental Ballistic Missile Fuze Modernization (ICBM Fuze Mod)
2015-12-01
Selected Acquisition Report ( SAR ) RCS: DD-A&T(Q&A)823-498 Air Force Intercontinental Ballistic Missile Fuze Modernization (ICBM Fuze Mod) As of FY...2015 SAR March 17, 2016 09:03:03 UNCLASSIFIED 2 Table of Contents Common Acronyms and Abbreviations for MDAP Programs 3 Program Information...Acquisition Unit Cost ICBM Fuze Mod December 2015 SAR March 17, 2016 09:03:03 UNCLASSIFIED 3 PB - President’s Budget PE - Program Element PEO - Program
Quality Surveillance Project No. 38-- Mk 9 MC-97 and MC-98 Fuze Setting-Torque Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandia Corporation Surveillance Department
1954-08-01
To determine the effects of stockpile storage on the torque required to set the functioning time on the MC-97 (Mechanical T-215 Time Fuze) and the MC-98 Mechanical T-220 Time Fuze). There were reports that the tool for setting the fuze time was breaking.
1992-01-01
00-892-4302 FUZE M557 8861213 1.1B 0106 16 19.4 N335 1390-01-080-4171 FUZE M557 8861213 1.4B 0257 16 19.4 N340 1390-00-574-7705 FUZE M739 8861213...1.1D 0408 16 20.9 N340-1390-01-080-9447 FUZE M739 8861213 1.2D 0409 16 20.9 N340 1390-01-132-7481 FUZE M739A1 8861213 1.2D 0409 16 20.9 N402 1390-00-764
1986-06-01
Flash 3. (342 g) Electrically Comp Actuated By Blasting Machine or Battery 5/ 8 STD 37524 Simulator, Projectile M1lSA2 0.30 7549246 MIL-S-10058 Hand...8799710 Blastin Comp (0.07 oz) Blasting (Whistle) Fuze Fuze 8-14 Frictio Friction (Burst) ’ l3AI M3A1 721 Igniter 8833721 Igniter last 5-10 8799714...8799715 iBlasti Blasting Sec FuzeN Fuze M3A1 •721 Igniter 8833721 Igniter Inst 6-10 8799714 879971 Blast Blasting See Fuze Puze N13A1 587 FrictLi 8848587
1989-04-01
W/Fuze Army/Marine M-2 PD, M508 Corps 1315-01-028-1234 Cartridge, 105mm, M360, W/Fuze Army/Marine PD, M557 Corps NOTE: The M739 (1390-N340) and M577...NOTE: The M739 1390-N340 point detonating (PD) fuze may also be used on this round. PROJECTILE, 155MM, M121A1 CHEEMICAL AGENT: GB; (1320-D542\\) CHEMICAL...1390-N340 Fuze, PD; M739 1390-00-574-7705 Prime Stock 1390-01-080-9447 Prime Stock 1390-01-032-7481 Alternate Stock 1390-N463 Fuze, Proximity, M728
2013-03-01
Proliferation Treaty OSINT Open Source Intelligence SAFF Safing, Arming, Fuzing, Firing SIAM Situational Influence Assessment Module SME Subject...expertise. One of the analysts can also be trained to tweak CAST logic as needed. In this initial build, only open-source intelligence ( OSINT ) will
2000-04-11
Untitled Document 44th Fuze Conference.html[6/8/ 2017 10:33:34 AM] Files are in Adobe Acrobat 3.0 format. 44th Annual Fuze Conference 11-12 April...United Kingdom Wednesday, April 12, 2000 Untitled Document 44th Fuze Conference.html[6/8/ 2017 10:33:34 AM] Rockwell Collins’ Artillery GPS Engine...cooperation with U.S experts Mitch Stone Texarkana , Texas Day & Zimmermann, Inc. - Lone Star Division We do what we say! þ History and Evolution þ
1983-09-01
AD IV) MEMORANDUM REPORT ARBRL-MR-03309 N(Supersedes IMR No. 760) A STRAIN -SONDE TECHNIQUE FOR THE MEASUREMENT OF MECHANICAL TIME- DELAY FUZE...and BkuWel) S. TYPE OF REPORT & PERIOD COVERED A STRAIN -SONDE TECHNIQUE FOR THE MEASUREMENT OF Final MECHANICAL TIME-DELAY FUZE FUNCTION TIMES AND S...nmber) M577 Mechanical Time-Delay Fuze F"/FM Telemeter Interlock Pin Release Semiconductor Strain Gage Rotor Signal Condition Amplifier Firing Pin In
Seal Integrity of Selected Fuzes as Measured by Three Leak Test Methods
1976-09-01
the worst fuze from the seal standpoint. The M503A-2 fuze body is made from a cast aluminum alloy . The casting process leaves voids which, after...leak resistance of the joint. WDU4A/A The design of this fuze depends upon ultrasonic welding to seal lid to case. The specified leak test merely...test is probably one of the better leakage tests from an effectiveness standpoint. However, from lot quantities of 690 and 480, reject rates of 20% were
Electronic Joint Army/Navy Point Detonating/Delay Fuze
1982-08-01
be battery powered and will use an existing S & A , such as an M739 . We recormiended that the fuzes be fired at various zones and high-speed cameras...Demonstrator 10 Power Supply Tasks 47 11 Electronic S & A 43 11.1 Explosive Barrier Module 49 11.2 Internal Development Program 51 12 Fuze Packaging...program, contract number DAAK10-80-C-0049. We included the Electronic S & A and Fuze Packaging sections to present a complete understanding of the overall
50th Annual Fuze Conference Session 5
2006-05-11
level •Underwater Shock NDIA Fuze Conf 2006 5 Warhead Lethality MOFN has two potential warheads EX 183 HE-MOFN •MK 64 PROJECTILE BODY • PBXN - 106 ...EXPLOSIVE FILL EX 184 HE-MOFN •HIFRAG PROJECTILE BODY • PBXN - 106 EXPLOSIVE FILL Warhead lethality effect is fragmentation NDIA Fuze Conf 2006 6 Warhead...NDIA Fuze Conf 2006 19 Min Engagement Hazard • Worst Case Operational Configuration: – Projectile = EX 184 HE-MOFN • MK 64 Projectile w PBXN - 106 fill
53rd Annual Fuze Conference - Next Generation Fuzing - Maximum Advantage for the Warfighter
2009-05-21
Time Engineering AB 3:00 pm BREAK 3:20 pm Advances In Thermal Batteries For Fuzing David E. Harney, Advanced Thermal Batteries , Inc...Currently teaming and collaborating with Advanced Thermal Batteries • and Omnitek Partners to develop an improved thermal battery. • Current
2005-04-01
with a single demolition block charge of C4 (DODIC M023) as the donor charge. An M739 point- detonating fuze (DODIC N340) was installed in each round...All rounds contained a supplementary TNT charge in the fuze well below the M739 fuze (see Appendix A). Figure 3 shows the setup common for all the...Charge, demolition block, Comp C4, M112 MA-97A003-007A 16 1390010809447 N340 Fuze, point detonating, M739 MA-84B007-013 7 Notes: Drawn from Fort
Echo power analysis and simulation of low altitude radio fuze
NASA Astrophysics Data System (ADS)
Chen, Xiaolu; Chen, Biao; Xu, Tao; Xu, Suqin
2013-01-01
The echo power from the earth gound which was received by fuze plays an important role in aerial defense missile, especially when the fuze is working in the look down mode. It is necessary to analyze and even simulate the echo power signals to enhance the missile's anti-jamming ability. In this paper, the quantity of echo power from the earth ground of low altitude radio fuze was analyzed in detail. Three boundary equations of area irradiated by electromagnetic beams were presented, which include two equidistant curve equations and one equal-Doppler curve equation. The relationship between the working mode and the critical height was analyzed. The calculating formula of echo power waveform was derived. And based on the derived formula, the correlation between the maximal echo power and the incident height was given and simulated, which would be helpful for the further researches of low altitude radio fuze.
Design and development of FZU-32/B bomb fuze initiator. Final report 23 Jun 72--15 Nov 73
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miazza, J.
1974-05-01
The primary objective of this program was to develop a cost effective, production engineered FZU-24/B Bomb Fuze Initiator. The initiator is an electric generating device which, when installed in the fuze charging well of general purpose bombs, is capable of deriving energy from the airstream passing the bomb in free fall and converting the energy into electric energy suitable for powering a bomb fuze. The objective was to be accomplished by means of a production engineering effort carried through the evolution of design, fabrication, assembly, test, and evaluation. The baseline for the design was Harry Diamond Laboratories' Drawing No. 11716160.more » A quantity of 60 units was fabricated and tested, in accordance with the production engineered design. After some additional redesign to correct identified deficiencies, 220 units were fabricated. These units were subjected to environmental, wind tunnel, and flight testing and performance requirements were met. The final unit design was designated the FZU-32/B Bomb Fuze Initiator.« less
46th Annual Gun and Missile Systems Conference and Exhibition. Volume 3 - Thursday
2011-09-01
Grade Sensors Through Use of Accelerated Aging Principles Mr. Scott Gift 11657 Modeling of the Autofrettage Processes of a Gun Barrel Mr. Sudhir...Emissions Measured on the Outer Portion of a Composite Barrel Ms. Rushie Ghimire GUN & MISSILE SYSTEMS ADDITIONAL AUTHORS GUN & MISSILE SYSTEMS...Transportation – Loading – Gun Fire to Barrel Exit – After Barrel Exit • Passing: Fuze safety devices remain safe; safe for disposal or safe for
Photonics technology development for optical fuzing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, J.J.; Geib, Kent Martin; von der Lippe, C.M.
2005-07-01
This paper describes the photonic component development, which exploits pioneering work and unique expertise at Sandia National Laboratories, ARDEC and the Army Research Laboratory by combining key optoelectronic technologies to design and demonstrate components for this fuzing application. The technologies under investigation for the optical fuze design covered in this paper are vertical cavity surface emitting lasers (VECSELs), integrated resonant cavity photodetectors (RCPD), and diffractive micro-optics. The culmination of this work will be low cost, robust, fully integrated, g-hardened components designed suitable for proximity fuzing applications. The use of advanced photonic components will enable replacement of costly assemblies that employmore » discrete lasers, photodetectors, and bulk optics. The integrated devices will be mass produced and impart huge savings for a variety of Army applications.« less
1976-04-01
Cartridge, M115B1, M148A1B1, M15#1B1-15MM J .. Shell, HEAT-T, M456A1-105MM Fuze, PD, M739 # prepared for Project Manager Munitions Production Base...ENGINEERS PLANT EQUIPMENT PACKAGE MODERNIZATION PROGRAM Volume 4-1 Report No. 75-86-R-4- MODEL LINE DEVELOPMENT FUZE,PD, M739 prepared for Project...In preparing the model line for the manufacture of piece parts for the M739 fuze, a number of facts became obvious and affect the detailed de- [ sign
Insensitive fuze train for high explosives
Cutting, Jack L.; Lee, Ronald S.; Von Holle, William G.
1994-01-01
A generic insensitive fuze train to initiate insensitive high explosives, such as PBXW-124. The insensitive fuze train uses a slapper foil to initiate sub-gram quantities of an explosive, such as HNS-IV or PETN. This small amount of explosive drives a larger metal slapper onto a booster charge of an insensitive explosive, such as UF-TATB. The booster charge initiates a larger charge of an explosive, such as LX-17, which in turn, initiates the insensitive high explosive, such as PBXW-124.
Insensitive fuze train for high explosives
Cutting, J.L.; Lee, R.S.; Von Holle, W.G.
1994-01-04
A generic insensitive fuze train to initiate insensitive high explosives, such as PBXW-124 is described. The insensitive fuze train uses a slapper foil to initiate sub-gram quantities of an explosive, such as HNS-IV or PETN. This small amount of explosive drives a larger metal slapper onto a booster charge of an insensitive explosive, such as UF-TATB. The booster charge initiates a larger charge of an explosive, such as LX-17, which in turn, initiates the insensitive high explosive, such as PBXW-124. 3 figures.
Development of Simulation Techniques for the M739 and M577 Fuzes
1984-04-01
AD-E401 166 CONTRACTOR RWRRT ARLCD-CR-84003 DEVELOPMENT OF SIMUILATION TECNQUES? FOR THE M739 , AND ýM577 FUZES GERARD G. LOWEN nvN-,qMA’qCSASSOCIAT04...DEVELOPMENT OF SIMULATION TECHNIQUES FOR THE M739 Final AND M4577 FUZES May 1982 - December 1983 6. PERFORMING ORO. REPORT NUMBER 7. AUTNOR(a) SI. CONTRACT...2 Variation of Escapement Center Distance on Number of Turns-to-Arm of the M739 S&A Mathematical Models of Clock Gear Train S&A 3 Forward Kinematics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taslitt, N.
1985-09-01
The objectives of this project were to (1) determine whether the radiation from a nuclear weapon can disable various arming and fuzing components by causing permanent damage; (2) determine whether transient nuclear radiation can induce an operating fuze to malfunction; and (3) compare nuclear weapon radiation effects with those produced by various radiation simulators. Data obtained revealed that none of the inertial components were detrimentally affected. The electronic components were severely degraded but would have satisfactorily accomplished their tactical functions. No electromagnetic effects were detected.
Overview of the Fusion Z-Pinch Experiment FuZE
NASA Astrophysics Data System (ADS)
Weber, T. R.; Shumlak, U.; Nelson, B. A.; Golingo, R. P.; Claveau, E. L.; McLean, H. S.; Tummel, K. K.; Higginson, D. P.; Schmidt, A. E.; UW/LLNL Team
2016-10-01
Previously, the ZaP device, at the University of Washington, demonstrated sheared flow stabilized (SFS) Z-pinch plasmas. Instabilities that have historically plagued Z-pinch plasma confinement were mitigated using sheared flows generated from a coaxial plasma gun of the Marshall type. Based on these results, a new SFS Z-pinch experiment, the Fusion Z-pinch Experiment (FuZE), has been constructed. FuZE is designed to investigate the scaling of SFS Z-pinch plasmas towards fusion conditions. The experiment will be supported by high fidelity physics modeling using kinetic and fluid simulations. Initial plans are in place for a pulsed fusion reactor following the results of FuZE. Notably, the design relies on proven commercial technologies, including a modest discharge current (1.5 MA) and voltage (40 kV), and liquid metal electrodes. Supported by DoE FES, NNSA, and ARPA-E ALPHA.
Shock sensing dual mode warhead
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shamblen, M.; Walchak, M.T.; Richmond, L.
1980-12-31
A shock sensing dual mode warhead is provided for use against both soft and hard targets and is capable of sensing which type of target has been struck. The warhead comprises a casing made of a ductile material containing an explosive charge and a fuze assembly. The ductile warhead casing will mushroom upon striking a hard target while still confining the explosive. Proper ductility and confinement are necessary for fuze shock sensing. The fuze assembly contains a pair of parallel firing trains, one initiated only by dynamic pressure caused high impact deceleration and one initiated by low impact deceleration. Themore » firing train actuated by high impact deceleration senses dynamic pressure transmitted, during deformation of the warhead, through the explosive filler which is employed as a fuzing signature. The firing train actuated by low impact deceleration contains a pyrotechnic delay to allow penetration of soft targets.« less
Design of diode-pumped solid-state laser applied in laser fuses
NASA Astrophysics Data System (ADS)
Deng, FangLin; Zhang, YiFei
2005-04-01
The function of laser fuzes which are parts of certain weapon systems is to control the blasting height of warheads. Commonly the battle environment these weapon systems are confronted with is very complicated and the tactical demand for them is very rigor, so laser fuzes equipped for them must fulfill some special technical requirements, such as high repetition rate, long ranging scope, etc. Lasers are one of key components which constitute fuze systems. Whether designed lasers are advanced and reasonable will determine whether laser fuzes can be applied in these weapon systems or not. So we adopt the novel technology of diode-pumped solid-state laser (DPSSL) to design lasers applied in fuzes. Nd:YVO4 crystal is accepted as gain material, which has wide absorption band and large absorption efficient for 808nm pumping laser. As warhead's temperature is usually very high, wider absorption band is beneficial to reduce the influence of temperature fluctuation. Passive Q-switching with Cr4+:YAG is used to reduce the power consumption farthest. Design the end-pumped microchip sandwich-architecture to decrease lasers' size and increase the reliability, further it's advantageous to produce short pulses and increase peak power of lasers. The designed DPSSL features small size and weight, high repetition rate and peak power, robustness, etc. The repetition rate is expected to reach 1 kHz; peak power will exceed 300 kW; pulse width is only 5 ns; and divergence angle of laser beams is less than 5 mrad. So DPSSL is suitable for laser fuzes as an emitter.
Development Program of Dual Mode Impact Delay Module for Artillery Fuzes.
1979-12-31
analysis phase to demonstrate design confidence and reliability of performance in the artillery firing environment. See Figure I for drawing of the latest...Device P/N KF88590 as proposed by us. This analysis will be based on results of penalty test« in which the test variables will include loading and...istently and unmistakably Dextrinated lead azide was, tent surrogate. On the basis of stab s Id be predicted that any system whi r mated lead azide
Properties of Ti-6Al-4V spun formed fuze supports
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moody, N.R.; Gates, G.
1985-05-01
Spin forming is designated as the primary fabrication process for the Ti-6A1-4V, W-87 fuze support. This process reduces the amount of rough machining during production, the cost of the starting material and the lead time from order to delivery of finished parts compared with parts made from forgings. However, because the amount of deformation from the spin forming process varies greatly within the part, the properties resulting from spin forming the fuze supports are unknown. This study shows that the properties and microstructure of the highly deformed walls of the fuze support are similar to those of forgings, while themore » properties and microstructure of the lightly deformed nose are similar to those of the parent plate. A solution treatment at 1750/sup 0/F/1h/WQ (954/sup 0/C) followed by a 900/sup 0/F (482/sup 0/C) four hour age gives the desired properties. Additionally, microstructural evaluation shows that the temperatures during spin forming are maintained within desired limits and that no significant microstructural changes occur during subsequent elevated temperature processing of the finished part. This study shows that solution treated and aged parts meet all required properties for all conditions to which the fuze supports will be subjected.« less
2006-06-01
were M107 high-explosive deep-cavity 155-mm howitzer projectiles with a supplemental charge and an M739 point- detonating fuze mounted in the nose...M107, HE, w/o fuze IOP03E100-011 14 1390010809447 N340 Fuze, point-detonating, M739 MA-84B007-013 14 1375014151232 ML47 Cap, blasting, non-electric 30... M739 N340 0 21 0 ə Cap, blasting, M11 ML47 ə 27 ə ə Cap, blasting, M13 MN03 0 ə 0 ə Cap, blasting, M14 MN06 0 0 0 ə Cord, detonating M456 0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Obrsky, J.; Alexander, A.A.; Griffen, O.H.
1980-12-31
A dual mode warhead is provided for use against both soft and hard targets and capable of sensing which type of target has been struck comprising a casing made of a ductile material containing an explosive charge and a fuze assembly. The ductile warhead casing will mushroom and later split upon striking a hard target while still confining the explosive. Proper ductility and confinement are necessary for fuze sensing. The fuze assembly contains a pair of parallel firing trains, one initiated only by high and one by low impact deceleration. The firing train actuated by low impact deceleration contains amore » pyrotechnic delay to allow penetration of soft targets.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eggers, P.E.
1975-03-01
An analytical study has been performed to assess the feasibility of using aerodynamically heated thermoelectric convertors to power RF proximity fuzes. The collective results of this study indicate that such a thermoelectric power supply is feasible for use with 20 mm projectiles and is compatible with the existing RF fuze circuit and safe arming distance requirements. A disc module concept has evolved from this study involving thin-film bismuth telluride as the basic thermoelectric element. Preliminary experimental studies were completed in order to identify principal parameters for the bismuth telluride.
Accuracy Improvement Capability of Advanced Projectile Based on Course Correction Fuze Concept
Elsaadany, Ahmed; Wen-jun, Yi
2014-01-01
Improvement in terminal accuracy is an important objective for future artillery projectiles. Generally it is often associated with range extension. Various concepts and modifications are proposed to correct the range and drift of artillery projectile like course correction fuze. The course correction fuze concepts could provide an attractive and cost-effective solution for munitions accuracy improvement. In this paper, the trajectory correction has been obtained using two kinds of course correction modules, one is devoted to range correction (drag ring brake) and the second is devoted to drift correction (canard based-correction fuze). The course correction modules have been characterized by aerodynamic computations and flight dynamic investigations in order to analyze the effects on deflection of the projectile aerodynamic parameters. The simulation results show that the impact accuracy of a conventional projectile using these course correction modules can be improved. The drag ring brake is found to be highly capable for range correction. The deploying of the drag brake in early stage of trajectory results in large range correction. The correction occasion time can be predefined depending on required correction of range. On the other hand, the canard based-correction fuze is found to have a higher effect on the projectile drift by modifying its roll rate. In addition, the canard extension induces a high-frequency incidence angle as canards reciprocate at the roll motion. PMID:25097873
Accuracy improvement capability of advanced projectile based on course correction fuze concept.
Elsaadany, Ahmed; Wen-jun, Yi
2014-01-01
Improvement in terminal accuracy is an important objective for future artillery projectiles. Generally it is often associated with range extension. Various concepts and modifications are proposed to correct the range and drift of artillery projectile like course correction fuze. The course correction fuze concepts could provide an attractive and cost-effective solution for munitions accuracy improvement. In this paper, the trajectory correction has been obtained using two kinds of course correction modules, one is devoted to range correction (drag ring brake) and the second is devoted to drift correction (canard based-correction fuze). The course correction modules have been characterized by aerodynamic computations and flight dynamic investigations in order to analyze the effects on deflection of the projectile aerodynamic parameters. The simulation results show that the impact accuracy of a conventional projectile using these course correction modules can be improved. The drag ring brake is found to be highly capable for range correction. The deploying of the drag brake in early stage of trajectory results in large range correction. The correction occasion time can be predefined depending on required correction of range. On the other hand, the canard based-correction fuze is found to have a higher effect on the projectile drift by modifying its roll rate. In addition, the canard extension induces a high-frequency incidence angle as canards reciprocate at the roll motion.
Analysis of base fuze functioning of HESH ammunitions through high-speed photographic technique
NASA Astrophysics Data System (ADS)
Biswal, T. K.
2007-01-01
High-speed photography plays a major role in a Test Range where the direct access is possible through imaging in order to understand a dynamic process thoroughly and both qualitative and quantitative data are obtained thereafter through image processing and analysis. In one of the trials it was difficult to understand the performance of HESH ammunitions on rolled homogeneous armour. There was no consistency in scab formation even though all other parameters like propellant charge mass, charge temperature, impact velocity etc are maintained constant. To understand the event thoroughly high-speed photography was deployed to have a frontal view of the total process. Clear information of shell impact, embedding of HE propellant on armour and base fuze initiation are obtained. In case of scab forming rounds these three processes are clearly observed in sequence. However in non-scab ones base fuze is initiated before the completion of the embedding process resulting non-availability of threshold thrust on to the armour to cause scab. This has been revealed in two rounds where there was a failure of scab formation. As a quantitative measure, fuze delay was calculated for each round and there after premature functioning of base fuze was ascertained in case of non-scab rounds. Such potency of high-speed photography has been depicted in details in this paper.
Mini-Warriors: Microelectromechanical Systems: A Munitions Revolution
2014-02-01
hand-held con- troller senses and transmits body movements to the video game—much like the Lycra suit with 85 MEMS, worn by ac- tors, which aided...for the anti-torpedo tor- pedo . Although it uses a macro-size fuze, significantly reduced in size by the Division, its experimental MEMS fuze informed
Failure analysis of fuze power supply
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menke, J.T.
1996-10-01
Batteries in storage which were used in electronic fuzes were found to be leaking after 5 years. The leaking battery ampules were made of copper and contained mixture of fluoboric acid and methylene bromide. The corrosion mechanism is described along with the testing/analysis required to simulate the field failures.
Inertial Impact Switches for Artillery Fuzes. Part III. Rocket Application
1975-04-01
INtWT.INiUUITO» iiTwar mN.coimcT Nom > i. minrtwotMutt. SLOTS IN END UP MO SCOVTOBCmUNC«ITH EMM OTMR WITHIN 10* SCCNOTC...ENGR LAB COMMANDER NAVAL SURFACE WEAPONS CENTER WHITE OAK, MD 20910 ATTN CODE 043 , PROJ MGR, FUZES ATTN CODE 511, ATTN CODE 512, ATTN CODE 522
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wehrle, R.D.
1953-06-18
The probability of the occurrence of rain during the "armed" portion of the fall of a bomb is approximately 1/25. Therefore, rain is considered a problem in premature detonation of the warhead through activation of the contact fuze system.
MC3196 Detonator Shipping Package Hazard Classification Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones; Robert B.
1979-05-31
An investigation was made to determine whether the MC3196 detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosives per 49 CFR 173.113. This study covers the Propagation Test and the External Heat Test as approved by DOE Albuquerque Operations Office. Test data led to the recommeded hazard classification of detonating fuze, Class C explosives.
Assessment of the MC3608 detonator shipping package hazard classification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, R.B.
1981-08-07
An investigation was made to determine whether the MC 3608 Detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosive, per 49 CFR 173.113. This study covers the propagation test as approved by DOE-Albuquerque Operations Office. Analysis of the test data led to the recommended hazard classification of Detonating Fuze, Class C Explosive.
77 FR 77040 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
... Laser Guided Bombs, 162 FMU-152 bomb fuzes, 150 BLU-111B/B 500-lb Conical Fin General Purpose Bombs (Freefall Tail), 60 BLU-111B/B 500-lb Retarded Fin General Purpose Bombs (Ballute Tail), and 32 CBU-105 Wind... (AMRAAM), 162 GBU-12 PAVEWAY II 500-lb Laser Guided Bombs, 162 FMU-152 bomb fuzes, 150 BLU- 111B/B 500-lb...
2008-10-01
ER D C/ CR R EL T R -0 8 -1 9 Energetic Residues from Blow-in-Place Detonation of 60-mm and 120-mm Fuzed High-Explosive Mortar Cartridges...Figure 4. Sample filtration setup. ............................................................................................................. 8 ...15 Table 8 . HE munitions BIP and live-fire detonation energetics residues data. .................................. 17 ERDC/CRREL TR-08
Ground-echo characteristics for a ground-target pulse-Doppler radar fuze of high duty ratio
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, C.S.
1973-11-21
From Tri-service electronic fuse symposium; Washington, District of Columbia, USA (26 Nov 1973). A pulse-Doppler radar fuze for use against ground targets at high burst heights can operate at low peak power provided a high duty ratio is used. The high duty ratio brings about ambiguous ground return that is prevented from firing the fuze by randomly coding the phase of the transmitted pulses. This causes the ambiguous return to appear as random noise. This paper provides formulas for the calculation of the clutter-noise power density and of the signal power so that the performance of the radar can bemore » determined. The paper also discusses the myth of decorrelation'' that is alleged to destroy the transmittedphase modulation in the echo and so make it useless. (auth)« less
Impact Sensors for Use with Electronic Fuzes
1975-12-01
corroborated the major features of a theoretical analysis. More work is needed to 10R. Wasser , Impact Switch Tests, US Naval Ordnance...might be more fruitful if more effort were expended on electro- mechanical systems. One principle that could be applied to such a l0R. Wasser ...Switches for Artillery Fuzes, Part I: Development, Harry Diamond Laboratories TM-72-18 (July 1972). (10) R. Wasser , Impact Switch TestP, US Naval
Bearing Survivability and Friction Determination for Fuze Decoupling Applications
2012-09-01
three types of ball bearings. The revolutions per minute versus time plots acquired from spin-down trials provide a qualitative view of bearing...ACKNOWLEDGMENTS The Dragon Bearing Team would like to thank Jason DeVenezia and Michael Hollis for their assistance in developing test fixtures...Optimized Navigation ( DRAGON ) program, the bearings would be used to decouple the fuze from the remainder of the body to mitigate drive actuation
Modified M505A3 Fuze with Delay Function
1974-10-01
forward initiation on the firing pin entrance hole to the rotor cavity. The triple staked detonator also functioned on the 0.063-inch target at 75... effectiveness of this projectile against aircraft targets by Incorporating a time delay which enables the projectile to penetrate the aircraft skin...prior to detonation. This effort required the design of modifications to the M505A3 fuze to achieve a delay function without modifying the rotor
2007-06-01
study), so tags placed in the fuze will allow both munitions to be tagged. • Fuze modification : o Four equally spaced grooves, 0.32 inches deep...investigation. Therefore, effort must continue to verify all recommendations before implementing the modifications . The list below highlights critical...concerns that require attention and verification: • Environmental o Manufacturing modifications to attach the tag Worker safety Bio friendliness o
Handbook of Ballistic and Engineering Data for Ammunition. Volume 1. 20-1-95 to 75-1-310 Included
1950-07-01
steel uistead of cast iron)witb the PD Fuze M52 as standard for limited procurement. OCM items 16026 and 16122 recommended and approved standardization of...BALLSTIC AND ENGINEERIN DATA II DRAG~E75 COFFCINT MACH NUMBER PLDT -14 44 SHELLI H5-mM .. a; FUZE,CPD, 7PI SEL;HEL, 75-MM M48; UE,TJ 3 fill 1.5 I . 2I
Development of an automated fuzing station for the future armored resupply vehicle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chesser, J.B.; Jansen, J.F.; Lloyd, P.D.
1995-03-01
The US Army is developing the Advanced Field Artillery System (SGSD), a next generation armored howitzer. The Future Armored Resupply Vehicle (FARV) will be its companion ammunition resupply vehicle. The FARV with automate the supply of ammunition and fuel to the AFAS which will increase capabilities over the current system. One of the functions being considered for automation is ammunition processing. Oak Ridge National Laboratory is developing equipment to demonstrate automated ammunition processing. One of the key operations to be automated is fuzing. The projectiles are initially unfuzed, and a fuze must be inserted and threaded into the projectile asmore » part of the processing. A constraint on the design solution is that the ammunition cannot be modified to simplify automation. The problem was analyzed to determine the alignment requirements. Using the results of the analysis, ORNL designed, built, and tested a test stand to verify the selected design solution.« less
Overview of the FuZE Fusion Z-Pinch Experiment
NASA Astrophysics Data System (ADS)
Shumlak, U.; Nelson, B. A.; Claveau, E. L.; Forbes, E. G.; Golingo, R. P.; Stepanov, A. D.; Weber, T. R.; Zhang, Y.; McLean, H. S.; Higginson, D. P.; Schmidt, A.; Tummel, K. K.
2017-10-01
Successful results of the sheared flow stabilized (SFS) Z-pinch from ZaP and ZaP-HD have motivated the new FuZE project to scale the plasma performance to fusion conditions. The SFS Z-pinch is immune to the instabilities that plague the conventional Z-pinch yet maintains the same favorable radial scaling. The plasma density and temperature increase rapidly with decreasing plasma radius, which naturally leads to a compact configuration at fusion conditions. The SFS Z-pinch is being investigated as a novel approach to a compact fusion device in a collaborative ARPA-E ALPHA project with the University of Washington and Lawrence Livermore National Laboratory. The project includes an experimental effort coupled with high-fidelity physics modeling using kinetic and fluid simulations. Along with scaling law analysis, computational and experimental results from the FuZE device are presented. This work is supported by an award from US ARPA-E.
2011-11-30
fuze separating from the shell body preventing high order detonations thus saving the lives of the Soldiers. Unit’s SPC Alan Ng with his father Peter...Sensitive If not fully compliant, must show improvement over Baseline explosive Affordable Artillery Cost Drivers = Steel Body Material & Explosive Fill...Mortar Cost Drivers = Steel Body Material, Fuze & Propelling Charges Producible within the National Technology and Industrial Base Infrastructure
Multiple Launch Rocket System (MLRS) Fuze.
1982-06-18
8217This is to be expected, since the probes are near the axis of symmetry 08 (where the bow shock wave is most nearly normal) and, being Pitot probes ...that simulated altitudes from 15.2 Km to 21 Km. The fuze ogive was instrumented with both static and pitot pressure probes , from which the pressure data...insights into the flow. Because the bow shock wave is curved, the static-pressure on the-- .urface should decrease from avalue__ of the stagnation pressure
Producing High-Performance, Stable, Sheared-Flow Z-Pinches in the FuZE project
NASA Astrophysics Data System (ADS)
Golingo, R. P.; Shumlak, U.,; Nelson, B. A.; Claveau, E. L.; Forbes, E. G.; Stepanov, A. D.; Weber, T. R.; Zhang, Y.; McLean, H. S.; Tummel, K. K.; Higginson, D. P.; Schmidt, A. E.; University of Washington (UW) Collaboration; Lawrence Livermore National Laboratory (LLNL) Collaboration
2017-10-01
The Fusion Z-Pinch Experiment (FuZE) has made significant strides towards generating high-performance, stable Z-pinch plasmas with goals of ne = 1018 cm-3 and T =1 keV. The Z-pinch plasmas are stabilized with a sheared axial flow that is driven by a coaxial accelerator. The new FuZE device has been constructed and reproduces the major scientific achievements the ZaP project at the University of Washington; ne = 1016 cm-3,T = 100 eV, r<1 cm, and tstable >20 μs. These parameters are measured with an array of magnetic field probes, spectroscopy, and fast framing cameras. The plasma parameters are achieved using a small fraction of the maximum energy storage and gas injection capability of the FuZE device. Higher density, ne = 5×1017 cm-3, and temperature, T = 500 eV, Z-pinch plasmas are formed by increasing the pinch current. At the higher voltages and currents, the ionization rates in the accelerator increase. By modifying the neutral gas profile in the accelerator, the plasma flow from the accelerator is maintained, driving the flow shear. Formation and sustainment of the sheared-flow Z-pinch plasma will be discussed. Experimental data demonstrating high performance plasmas in a stable Z-pinches will be shown. This work is supported by an award from US ARPA-E.
1982-11-01
Report) IS. SUPPLEMENTARY NOTES It. KEY WORDS (Contin~ue an reverse aide It neoocemry and Identity by block number) Gear train S&A mechanism M739 fuze...as in the escapement. A simulation run with the dimensions of the M739 safing and arming mechanism showed excellent agreament with experimental...well as all non-impact contact forces. This program was extensively tested for the configuration no. 2 data (fig. 2) of the M739 fuze S&A mechanism
Exploratory Development on an Electronic Safing and Arming Device for Ordnance Fuzing
1983-02-01
to the bridges. Two units were subjected to MIL-STD-331, Test 101, Jolt. The EBMs were placed in the S & A cavity of an M739 fuze body for this test...of the program was to explore a concept for a safe, reliable, general purpose, low cost, electronic, A ’ zsafing and arming ( S & A ) system for use in...breadboard model hardware of the electronic S & A device. The electronic S & A devicu consists of an explosive barrier moduls (EBM) explosive train
1985-01-01
brigade to battery inclusive. Interchangeability of all dry cells for all F. A. equipment. Kinds of projectiles fuzes and charges in use at...Battery, inclusive. Interchangeability of all dry cells used for all Field Artillery equipment. Kinds of projectiles and fuzes in use at present...obtaining horses of sufficient stamins and in sufficient numbers to properly handle the ammunition supply during combat, together with the serious
2011-04-01
1-9. R esources N ot C arried Forw ard for D etailed A nalysis Legend Environmental Justice Concerns c:::J Proposed Project Area No Concerns...11 FEF/FIF C onstruction Environm ental A ssessm ent Page 3-6 Eglin A ir Force B ase, FL Final Figure 3-1. W ater R esources A t or N...Ecological A ssociations and Biological R esources A t or N ear the Proposed A ction Location Ecological Association Flatwoods Landscaped!Urban c:J
Detection of fuze defects by image-processing methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, M.J.
1988-03-01
This paper describes experimental studies of the detection of mechanical defects by the application of computer-processing methods to real-time radiographic images of fuze assemblies. The experimental results confirm that a new algorithm developed at Materials Research Laboratory has potential for the automatic inspection of these assemblies and of others that contain discrete components. The algorithm was applied to images that contain a range of grey levels and has been found to be tolerant to image variations encountered under simulated production conditions.
Prototype Automated Equipment to Perform Poising and Beat Rate Operations on the M577 MTSQ Fuze.
1978-09-30
Regulation Machine which sets the M577 Fuze Timer beat rate and the Automatic Poising Machine which J dynamically balances the Timer balance wheel...in trouble shooting., The Automatic Poising Machine Figure 3 which inspects and corrects the dynamic I balance of the Balance Wheel Assembly was...machine is intimately related to the fastening method of the wire to the Timer at one end and the Balance Wheel at the other, a review of the history
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFarge, R.A.
1990-05-01
MCPRAM (Monte Carlo PReprocessor for AMEER), a computer program that uses Monte Carlo techniques to create an input file for the AMEER trajectory code, has been developed for the Sandia National Laboratories VAX and Cray computers. Users can select the number of trajectories to compute, which AMEER variables to investigate, and the type of probability distribution for each variable. Any legal AMEER input variable can be investigated anywhere in the input run stream with either a normal, uniform, or Rayleigh distribution. Users also have the option to use covariance matrices for the investigation of certain correlated variables such as boostermore » pre-reentry errors and wind, axial force, and atmospheric models. In conjunction with MCPRAM, AMEER was modified to include the variables introduced by the covariance matrices and to include provisions for six types of fuze models. The new fuze models and the new AMEER variables are described in this report.« less
Angular Motion of Projectiles with a Moving Internal Part.
1977-02-01
Ball Rotor T317 hellIntermal Projectile RingsM505 Fuze Quasi-linear Angular Motion N\\ ANSTRACT (-jCanhs si rveree side ff naeweemv end identify by...LIST OF FIGURES Figure Page 1. 20mm Shell T282E1 with Arming Ball Rotor .... .......... 20 2. Fast Mode Damping Rate for the 20mm T282E1...fuze has a spherical arming rotor in a cylindrical cavity with small but non-zero clearanc’es (Figure 1). The fourth sa.ell - the 8-inch T317 - showed
Meeting the Challenge: A 1986 History of the Naval Surface Weapons Center
1987-05-29
8217GClK JACK lMUITRIUXER DIG Iot I ---, , SUpFt S COMPUTER ’ HEL DE Osi cOeiTROLPRiOCESSO HIGM SPEED ATA BUS OM SWR AU VAGKTtC BIBS11 Closed-Loop...appear. HVAC designers think it can determine if closures need to be installed on ventilation inlets to prevent the ingress of exhaust gases from...and fuze timing errors. If the fuze could be caused to actuate based on target position rather than a predicted time of flight, these errors could be
Hazard classification assessment for the MC3423 detonator shipping package
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, R.B.
1981-11-05
An investigation was made to determine whether the MC3423 detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosive, per Federal Register 49 CFR 173.113, when packaged as specified. This study covers two propagation tests which evaluated the effects of two orientations of the MC3423 in its shipping tray. The method of testing was approved by DOE, Albuquerque Operations Office. Test data led to the recommended hazard classification of Detonating Fuze, Class C Explosive for both orientations of the detonator.
Critical energy for shock initiation of fuze train explosives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, F.E.; Wasley, R.J.; Green, L.G.
1973-01-01
Results of shock initiation experiments conducted for tetryl and A-5 are presented, along with some data on the shock initiation of other explosives. The experiments were conducted using a gun system. An equation which has been useful in correlating these shock data is given. Some applications of the critical energy concept (represented by the above equation), to explosive train designs for NASA space systems are included. The concept's usefulness to DOD ordnance agencies now replacing tetryl in fuze trains with A-5 is also indicated. (auth)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hochuli, U.; McGuire, D.
1982-10-01
The properties of a compact, transversely excited, pulsed CO/sub 2/ waveguide laser are studied experimentally with the application of such a laser for an optical fuze transmitter in mind. Such parameters as peak power, pulse width, pulse shape, pulse jitter, repetition rate, beam profile, polarization, laser life, and optimum as mixture are investigated both for 10.6 and 9.6 micron output wavelengths, and for both sealed-off and flowing-gas operation of the laser. A computer simulation of the laser's operation is compared with the experimental results.
Digital Device Architecture and the Safe Use of Flash Devices in Munitions
NASA Technical Reports Server (NTRS)
Katz, Richard B.; Flowers, David; Bergevin, Keith
2017-01-01
Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Digital devices of interest to designers include flash-based microcontrollers and field programmable gate arrays (FPGAs). Almost a decade ago, a study was undertaken to determine if flash-based microcontrollers could be safely used in fuzes and, if so, how should such devices be applied. The results were documented in the Technical Manual for the Use of Logic Devices in Safety Features. This paper will first review the Technical Manual and discuss the rationale behind the suggested architectures for microcontrollers and a brief review of the concern about data retention in flash cells. An architectural feature in the microcontroller under study will be discussed and its use will show how to screen for weak or failed cells during manufacture, storage, or immediately prior to use. As was done for microcontrollers a decade ago, architectures for a flash-based FPGA will be discussed, showing how it can be safely used in fuzes. Additionally, architectures for using non-volatile (including flash-based) storage will be discussed for SRAM-based FPGAs.
Recommended Replacements for Tetryl in Australian Production Fuzes and Related Ordnance,
1987-11-01
RDX/AC629 as lead filling confirms comparable or better performance by RDX/AC629 on either of the RDX-based boosters. A -5 leads in Fuze M739 are... S . zinc stearate/graphite 98.0:1.25:0.5:0.25 Comparison: Debrix 18AS 120 1.496 a Extrapolated from data for 98.94:1.06 and 98.69:1.31 formulations...71P 8 1 ~ Aq CENEN on FO A R IAN L/I t A IF. I 4JrgALs RLj A ) R SF L. 6UN~cLASSIFIED -- IM DO AA - 14 F/G 19/1 NL . 1I.. EL6 ’ I lin MRL-R-.lO89 AR
DOE Office of Scientific and Technical Information (OSTI.GOV)
KIPP, MARLIN E.
2001-12-01
Explosive charges placed on the fuze end of a drained chemical munition are expected to be used as a means to destroy the fuze and burster charges of the munition. Analyses are presented to evaluate the effect of these additional initiation charges on the fragmentation characteristics for the M121A1 155mm chemical munition, modeled with a T244 fuze attached, and to assess the consequences of these fragment impacts on the walls of a containment chamber--the Burster Detonation Vessel. A numerical shock physics code (CTH) is used to characterize the mass and velocity of munition fragments. Both two- and three-dimensional simulations ofmore » the munition have been completed in this study. Based on threshold fragment velocity/mass results drawn from both previous and current analyses, it is determined that under all fragment impact conditions from the munition configurations considered in this study, no perforation of the inner chamber wall will occur, and the integrity of the Burster Detonation Vessel is retained. However, the munition case fragments have sufficient mass and velocity to locally damage the surface of the inner wall of the containment vessel.« less
Signal-processing analysis of the MC2823 radar fuze: an addendum concerning clutter effects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jelinek, D.A.
1978-07-01
A detailed analysis of the signal processing of the MC2823 radar fuze was published by Thompson in 1976 which enabled the computation of dud probability versus signal-to-noise ratio where the noise was receiver noise. An addendum to Thompson's work was published by Williams in 1978 that modified the weighting function used by Thompson. The analysis presented herein extends the work of Thompson to include the effects of clutter (the non-signal portion of the echo from a terrain) using the new weighting function. This extension enables computation of dud probability versus signal-to-total-noise ratio where total noise is the sum of themore » receiver-noise power and the clutter power.« less
Enhancing Energy in Future Conventional Munition
NASA Astrophysics Data System (ADS)
Peiris, Suhithi
2017-06-01
Future conventional weapons are envisioned to contain more energy per volume than current weapons. Current weapons comprise of inert steel outer case, with inner volume for energetic materials, fuzing, sensor package, propulsion system, etc. Recent research on reactive materials (RM) & new energetics, and exploiting additive manufacturing can optimize the use of both mass and volume to achieve much higher energy in future weapons. For instance, replacing inert steel with RM of similar strength, additively manufacturing fuzing packages within the weapon form factor, and combing the whole with new energetics, will enable the same lethality effects from smaller weapons as obtained from today's larger weapons. This paper will elaborate on reactive materials and properties necessary for optimal utilization in various weapon features, and touch on other aspects of enhancing energy in future conventional munition.
Sandia Research and Development Board: Minutes of the 33rd Meeting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castle, M.
1950-02-08
Notes about the barometric fuzing system testing, drops of stockpile weapons requested by the Strategic Air Command, simultaneous drops and the interaction of the baro systems, changes of desired military characteristics of atomic weapons.
Harrison, Thomas R.
1989-08-22
A proximity fuze system includes an optical ranging apparatus, a detonation circuit controlled by the optical ranging apparatus, and an explosive charge detonated by the detonation cirtcuit. The optical ranging apparatus includes a pulsed laser light source for generating target ranging light pulses and optical reference light pulses. A single lens directs ranging pulses to a target and collects reflected light from the target. An optical fiber bundle is used for delaying the optical reference pulses to correspond to a predetermined distance from the target. The optical ranging apparatus includes circuitry for providing a first signal depending upon the light pulses reflected from the target, a second signal depending upon the light pulses from the optical delay fiber bundle, and an output signal when the first and second signals coincide with each other. The output signal occurs when the distance from the target is equal to the predetermined distance form the target. Additional circuitry distinguishes pulses reflected from the target from background solar radiation.
Computing the apparent centroid of radar targets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, C.E.
1996-12-31
A high-frequency multibounce radar scattering code was used as a simulation platform for demonstrating an algorithm to compute the ARC of specific radar targets. To illustrate this simulation process, several targets models were used. Simulation results for a sphere model were used to determine the errors of approximation associated with the simulation; verifying the process. The severity of glint induced tracking errors was also illustrated using a model of an F-15 aircraft. It was shown, in a deterministic manner, that the ARC of a target can fall well outside its physical extent. Finally, the apparent radar centroid simulation based onmore » a ray casting procedure is well suited for use on most massively parallel computing platforms and could lead to the development of a near real-time radar tracking simulation for applications such as endgame fuzing, survivability, and vulnerability analyses using specific radar targets and fuze algorithms.« less
Estimate of Errors of Pressure Predictions Without Meteorological Forecasts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1957-07-31
Independent methods of estimating pressure were considered-- the range of application in height is from that of baro-fuzed tactical weapons (a few thousand feet) to that of the control of height of aircraft at high altitude (45,000 feet).
Fuze for explosive magnetohydrodynamic generator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webb, G.
1976-12-23
An apparatus is examined by which high explosive charges are propelled into and detonated at the center of an MHD-X generator. The high explosive charge units are engaged and propelled by a reciprocating ram device. Detonating in each instance is achieved by striking with a firing pin a detonator charge that is in register with a booster charge, the booster charge being in detonating communication with the high explosive charge. Various safety requirements are satisfied by a spring loaded slider operating in a channel transverse and adjacent to the booster charge. The slide retains the detonator charge out of registermore » with the booster charge until a safety pin that holds the slider in place is pulled by a lanyard attached between the reciprocating ram and the safety pin. Removal of the safety pin permits the detonator charge to slide into alignment with the booster charge. Firing pin actuation is initiated by the slider at the instant the detonator charge and the booster charge come into register.« less
1948-06-01
document states that the practice of galvanising aircraft bombs has ceased, and that a protective coat of paint is now used instead. These colourings...that the Italians are still in possession of large stocks of galvanised bombs. SECTION I CHEMICAL WARFARE BOMBS No. C.W. bombs have yet been
Impact fuze testing at 3000 m/sec employing explosively accelerating plates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gill, W.
1981-01-01
The Explosives Testing Division at Sandia has developed a method of simulating a re-entry vehicle impacting the ground. The purpose of the simulation is to evaluate different fusing concepts. The design and operation of this impact testing facility are described.
Harrison, T.R.
1987-07-10
A proximity fuze system includes an optical ranging apparatus, a detonation circuit controlled by the optical ranging apparatus, and an explosive charge detonated by the detonation circuit. The optical ranging apparatus includes a pulsed laser light source for generating target ranging light pulses and optical reference light pulses. A single lens directs ranging pulses to a target and collects reflected light from the target. An optical fiber bundle is used for delaying the optical reference pulses to correspond to a predetermined distance from the target. The optical ranging apparatus includes circuitry for providing a first signal depending upon the light pulses reflected from the target, a second signal depending upon the light pulses from the optical delay fiber bundle, and an output signal when the first and second signals coincide with each other. The output signal occurs when the distance from the target is equal to the predetermined distance from the target. Additional circuitry distinguishes pulses reflected from the target from background solar radiation. 3 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison, T.R.
1987-07-10
A proximity fuze system includes an optical ranging apparatus, a detonation circuit controlled by the optical ranging apparatus, and an explosive charge detonated by the detonation circuit. The optical ranging apparatus includes a pulsed laser light source for generating target ranging light pulses and optical reference light pulses. A single lens directs ranging pulses to a target and collects reflected light from the target. An optical fiber bundle is used for delaying the optical reference pulses to correspond to a predetermined distance from the target. The optical ranging apparatus includes circuitry for providing a first signal depending upon the lightmore » pulses reflected from the target, a second signal depending upon the light pulses from the optical delay fiber bundle, and an output signal when the first and second signals coincide with each other. The output signal occurs when the distance from the target is equal to the predetermined distance from the target. Additional circuitry distinguishes pulses reflected from the target from background solar radiation. 3 figs.« less
A Sandia weapon review bulletin : defense programs, Autumn 1992.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-09-01
Topics in this issue: (1) Focal Point and STEP. Sandia National Laboratories has always focused its advanced weapon development not only on future weapon needs, but also on the engineering and manufacturing sciences needed to meet them. Both areas are changing dramatically. As the nation dismantles many of its warheads, it becomes essential that those that remain are increasingly reliable, secure, capable, and safe. And as development resources diminish, it becomes vital that they are applied to the most critical technologies in a disciplined manner. The mission of the Focal Point program and the Stockpile Transition Enabling Program (STEP) ismore » to develop processes for meeting these challenges. Focal Point offers a decision-making process for allocating Sandia's resources to meets its defense programs strategic goals. (2) Defense Programs news in brief. (3) Dismantling the nuclear stockpile. (4) W88/MK5: Arming, Fuzing, and Firing system meets all requirements and goals. (5) The Common Radar Fuze. (6) Insertable-explosive arming of firing sets. (7) Preparing for fewer underground tests.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison, T.R.
1989-08-22
A proximity fuze system is described. It includes an optical ranging apparatus, a detonation circuit controlled by the optical ranging apparatus, and an explosive charge detonated by the detonation circuit. The optical ranging apparatus includes a pulsed laser light source for generating target ranging light pulses and optical reference light pulses. A single lens directs ranging pulses to a target and collects reflected light from the target. An optical fiber bundle is used for delaying the optical reference pulses to correspond to a predetermined distance from the target. The optical ranging apparatus includes circuitry for providing a first signal dependingmore » upon the light pulses reflected from the target, a second signal depending upon the light pulses from the optical delay fiber bundle, and an output signal when the first and second signals coincide with each other. The output signal occurs when the distance from the target is equal to the predetermined distance from the target. Additional circuitry distinguishes pulses reflected from the target from background solar radiation.« less
A Hardware Platform for Characterizing and Validating 1-Dimensional Optical Systems
2014-09-01
principle laboratory experiments, a bread -board sensor and data collection system was created to gather fuze data to postprocess after the event...merely differentiates this bistable memory category from dynamic random access memory [RAM], which must be periodically refreshed to retain data.) A
42nd Annual Armament Systems: Gun and Missile Systems
2007-04-26
to compare the various contenders: • FCS • Aero and flight dynamics of rounds • Phit and lethality • Direct and indirect fire capability Defence R&D...each other). • Guidance: Unguided, Command Guidance, Lock on Before Launch, Autonomous (needs Phit analysis). • Fuzing: Proximity – RF or Optical
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charles, B.N.
1955-05-12
Charts of the geographical distribution of the annual and seasonal D-values and their standard deviations at altitudes of 4500, 6000, and 7000 feeet over Eurasia are derived, which are used to estimate the frequency of baro system errors.
Strategies for Controlling Plug Loads. A Tool for Reducing Plug Loads in Commercial Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torcellini, Paul; Bonnema, Eric; Sheppy, Michael
2015-09-01
Plug loads are often not considered as part of the energy savings measures in Commercial Buildings; however, they can account for up to 50% of the energy used in the building. These loads are numerous and often scattered throughout a building. Some of these loads are purchased by the owner and some designed into the building or the tenant finishes for a space. This document provides a strategy and a tool for minimizing these loads.
1980-01-31
SANDMILLISEC HARD SAND .. : 33 20!~ U SMOKE EXIT RELATIONSHIP pd TO XMBO04 PROJ SURIAL DEPTH AS A FUNCTION OF EXIT HOLE LOCATION IMP VEL - 900 PT/SIC IMP...distance between the be determined. Adenes evlope for then obser- 30% ordinate and 16% or 84% The 0confidence level" d- Ttons was derived as follows
PEO Ammunition Systems Portfolio Book 2012-2013
2011-02-02
assembly. Aluminum ogive contains firing pin, a rubber anti-creep spring and M550 fuze escapement assembly and is threaded to projectile body...51 The Mortar Weapons and Fire Control Family M95/M96 Mortar Fire Control System (MFCS) – Mounted...52 M150/M151 Mortar Fire Control System Dismounted (MFCS-D
Further Development, Fabrication, and Testing of XM36E1 Fuze Setter
1978-08-01
primary func- tion of this circuit, has the same timing characteristics as the original circuit: Half-period pulses are required to be greater than...temperature of -40 0 C. 9 The following corrective action was taken for this mal- fuction : (1) The batteries were replaced, and an investigation of battery
76 FR 76954 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-09
... Bombs, 1000 BLU-117 2000lb General Purpose Bombs, 600 BLU-109 2000lb Hard Target Penetrator Bombs, and four BDU-50C inert bombs, fuzes, weapons integration, munitions trainers, personnel training and... kits, 3300 BLU-111 500lb General Purpose Bombs, 1000 BLU-117 2000lb General Purpose Bombs, 600 BLU-109...
U. S. Naval Forces, Vietnam Monthly Historical Summary for December 1970
1971-02-15
cable 3 cans of pull friction fuze lighters 2 electronic repair kits 1 bag of outboard motor repair parts 4 large bags of medical supplies and food ...problems encountered in the operation such as an operation order in Franch which the Vietnamese participants could not readsand raw and un:rained Cambodian
50th Annual Fuze Conference. Session 1 and 2
2006-05-11
PROGRAM OFFICE AMSRD-AAR-AIJ J. Goldman X6060 STRATEGIC MGT OFFICE AMSRD-AAR-EMS D. Denery X6081 KNOWLEDGE MANAGEMENT OFFICE AMSRD-AAR-EMK G. Albinson...Tail-Mounted Configuration (MK-82 Demo) UHF to L-Band Pulse Doppler Radar Using Low Cost COTS Components Nose and Tail Mount Configurations Only
Environmental Effects on Data Retention in Flash Cells
NASA Technical Reports Server (NTRS)
Katz, Rich; Flowers, David; Bergevin, Keith
2017-01-01
Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Antifuse technology, prevalent in non-volatile field programmable gate arrays (FPGAs), will eventually be phased out as new devices have not been developed for approximately a decade. The reliance on flash technology presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. This paper will present the results of our on-going tests: long-term storage at 150 C for a small population of devices, neutron radiation exposure, electrostatic discharge (ESD) testing, and the trends of large populations (over 300 devices for each condition) exposed to three difference temperatures: 25 C, 125 C, and 150 C.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, Michael K.; Davidson, Megan
As part of Sandia’s nuclear deterrence mission, the B61-12 Life Extension Program (LEP) aims to modernize the aging weapon system. Modernization requires requalification and Sandia is using high performance computing to perform advanced computational simulations to better understand, evaluate, and verify weapon system performance in conjunction with limited physical testing. The Nose Bomb Subassembly (NBSA) of the B61-12 is responsible for producing a fuzing signal upon ground impact. The fuzing signal is dependent upon electromechanical impact sensors producing valid electrical fuzing signals at impact. Computer generated models were used to assess the timing between the impact sensor’s response to themore » deceleration of impact and damage to major components and system subassemblies. The modeling and simulation team worked alongside the physical test team to design a large-scale reverse ballistic test to not only assess system performance, but to also validate their computational models. The reverse ballistic test conducted at Sandia’s sled test facility sent a rocket sled with a representative target into a stationary B61-12 (NBSA) to characterize the nose crush and functional response of NBSA components. Data obtained from data recorders and high-speed photometrics were integrated with previously generated computer models in order to refine and validate the model’s ability to reliably simulate real-world effects. Large-scale tests are impractical to conduct for every single impact scenario. By creating reliable computer models, we can perform simulations that identify trends and produce estimates of outcomes over the entire range of required impact conditions. Sandia’s HPCs enable geometric resolution that was unachievable before, allowing for more fidelity and detail, and creating simulations that can provide insight to support evaluation of requirements and performance margins. As computing resources continue to improve, researchers at Sandia are hoping to improve these simulations so they provide increasingly credible analysis of the system response and performance over the full range of conditions.« less
45. BUILDING NO. 462, CHEMISTRY LAB (FORMERLY TRACER LOADING BUILDING), ...
45. BUILDING NO. 462, CHEMISTRY LAB (FORMERLY TRACER LOADING BUILDING), VIEW LOOKING SOUTHEAST AT WEST SIDE. BUILDING NO. 462-B, GENERAL PURPOSE MAGAZINE, AT LEFT. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
Present Capability of Ram Air-Driven Alternators Developed at HDL as Fuze Power Supplies
1983-07-01
DRCPI-HD, HELLFIRE/GLD FT MONMOUTH, NJ 07703 ATTN DRCPM-PEv PERSHING ATTN DRCPM-DT, TOM DRAGON DIRECTOR REDSTONE ARSENAL, AL 35809 ELECTRONICS TECHNOLOGY...00211 ATTN G. POPE, 00211 ATTN C. LANHAM, 00213 ATTi C. SPYROPOULOS, 22100 ATTN P. INGERSOLL, 34000 ATTN J. BEARD , 34200 ATn D. BROGU., 34300 I ATTN
10. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), ...
10. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), LOOKING AT SOUTHEAST CORNER. BUILDING NO. 332, CHANGE HOUSE, IN RIGHT BACKGROUND; BUILDING NO. 445-F, MAGAZINE, IN LEFT BACKGROUND. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
2011-05-26
concrete plate and compact soil Confirmation: Complete Success both tests The TDD functioned as programmed; traces show entry and exit from each...concrete target and difference in deceleration levels between concrete and soil configuration The final exit & fire signals were generated as planned...Technical Data Package • Determine Process Capability • FMEA Manufacturing • Determine process capability • Cp = ( USL -LSL)/(6*Sigma) • Cpl
34th Annual Gun and Ammunitions Symposium and Exhibition held in Monterey, CA on 26-29 April 1999
1999-04-01
Allan Buckley, Oerlikon Contraves ൫/50MM HETF (High Explosive Time Fuze) Ammunition" by Mr. Stephen Kerk and Mr. Peter Moore,* Diehl Stifung & Co...Technologies, Inc. "OICW Fire Control System" by Mr. Grant Moule*; Ms. Susan Franciscus*, Contraves Brashear Systems L.P. "Air Bursting Systems" by Mr. John
2009-09-01
exploding foil initiator ( EFI ) type fuzes are being explored to...Acronyms Au gold Cr chromium Cu copper EFI exploding foil initiator BOE buffered oxide etch MEMS microelectromechanical systems RIE reactive ion...Patterning of Thick Parylene Films by Oxygen Plasma for Application as Exploding Foil Initiator Flyer Material by Eugene Zakar and Michael
Against the Wind: Five South Africans Follow Their Dreams.
ERIC Educational Resources Information Center
Lewis, Lesley
This book for beginning readers tells the story of five South Africans who, though not very famous, all did things that no black South African had ever done before. They include: Simon Mkhize who, year after year, ran the Comrades Marathon unofficially, ignoring its racial bans; Magema M. Fuze, who was the first black South African to publish a…
Modeling and Analysis of Commercial Building Electrical Loads for Demand Side Management
NASA Astrophysics Data System (ADS)
Berardino, Jonathan
In recent years there has been a push in the electric power industry for more customer involvement in the electricity markets. Traditionally the end user has played a passive role in the planning and operation of the power grid. However, many energy markets have begun opening up opportunities to consumers who wish to commit a certain amount of their electrical load under various demand side management programs. The potential benefits of more demand participation include reduced operating costs and new revenue opportunities for the consumer, as well as more reliable and secure operations for the utilities. The management of these load resources creates challenges and opportunities to the end user that were not present in previous market structures. This work examines the behavior of commercial-type building electrical loads and their capacity for supporting demand side management actions. This work is motivated by the need for accurate and dynamic tools to aid in the advancement of demand side operations. A dynamic load model is proposed for capturing the response of controllable building loads. Building-specific load forecasting techniques are developed, with particular focus paid to the integration of building management system (BMS) information. These approaches are tested using Drexel University building data. The application of building-specific load forecasts and dynamic load modeling to the optimal scheduling of multi-building systems in the energy market is proposed. Sources of potential load uncertainty are introduced in the proposed energy management problem formulation in order to investigate the impact on the resulting load schedule.
Advanced Analog Signal Processing for Fuzing Final Report CRADA No. TC-1306-96
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fu, C. Y.; Spencer, D.
The purpose of this CRADA between LLNL and Kaman Aerospace/Raymond Engineering Operations (Raymond) was to demonstrate the feasibility of using Analog/Digital Neural Network (ANN) Technology for advanced signal processing, fuzing, and other applications. This cooperation sought to Ieverage the expertise and capabilities of both parties--Raymond to develop the signature recognition hardware system, using Raymond’s extensive experience in the area of system development plus Raymond’s knowledge of military applications, and LLNL to apply ANN and related technologies to an area of significant interest to the United States government. This CRADA effort was anticipated to be a three-year project consisting of threemore » phases: Phase I, Proof-of-Principle Demonstration; Phase II, Proof-of-Design, involving the development of a form-factored integrated sensor and ANN technology processo~ and Phase III, Final Design and Release of the integrated sensor and ANN fabrication process: Under Phase I, to be conducted during calendar year 1996, Raymond was to deliver to LLNL an architecture (design) for an ANN chip. LLNL was to translate the design into a stepper mask and to produce and test a prototype chip from the Raymond design.« less
An Evaluation of Flash Cells Used in Critical Applications
NASA Technical Reports Server (NTRS)
Katz, Rich; Flowers, David; Bergevin, Keith
2016-01-01
Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.
Termites utilise clay to build structural supports and so increase foraging resources.
Oberst, Sebastian; Lai, Joseph C S; Evans, Theodore A
2016-02-08
Many termite species use clay to build foraging galleries and mound-nests. In some cases clay is placed within excavations of their wooden food, such as living trees or timber in buildings; however the purpose for this clay is unclear. We tested the hypotheses that termites can identify load bearing wood, and that they use clay to provide mechanical support of the load and thus allow them to eat the wood. In field and laboratory experiments, we show that the lower termite Coptotermes acinaciformis, the most basal species to build a mound-nest, can distinguish unloaded from loaded wood, and use clay differently when eating each type. The termites target unloaded wood preferentially, and use thin clay sheeting to camouflage themselves while eating the unloaded wood. The termites attack loaded wood secondarily, and build thick, load-bearing clay walls when they do. The termites add clay and build thicker walls as the load-bearing wood is consumed. The use of clay to support wood under load unlocks otherwise unavailable food resources. This behaviour may represent an evolutionary step from foraging behaviour to nest building in lower termites.
1980-05-01
engineering ,ZteNo D R RPTE16 research w 9 laboratory COMPARISON OF BUILDING LOADS ANALYSIS AND SYSTEM THERMODYNAMICS (BLAST) AD 0 5 5,0 3COMPUTER PROGRAM...Building Loads Analysis and System Thermodynamics (BLAST) computer program. A dental clinic and a battalion headquarters and classroom building were...Building and HVAC System Data Computer Simulation Comparison of Actual and Simulated Results ANALYSIS AND FINDINGS
13. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), ...
13. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), VIEW NORTH AT SOUTH END OF BUILDING. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
Comfort air temperature influence on heating and cooling loads of a residential building
NASA Astrophysics Data System (ADS)
Stanciu, C.; Șoriga, I.; Gheorghian, A. T.; Stanciu, D.
2016-08-01
The paper presents the thermal behavior and energy loads of a two-level residential building designed for a family of four, two adults and two students, for different inside comfort levels reflected by the interior air temperature. Results are intended to emphasize the different thermal behavior of building elements and their contribution to the building's external load. The most important contributors to the building thermal loss are determined. Daily heating and cooling loads are computed for 12 months simulation in Bucharest (44.25°N latitude) in clear sky conditions. The most important aspects regarding sizing of thermal energy systems are emphasized, such as the reference months for maximum cooling and heating loads and these loads’ values. Annual maximum loads are encountered in February and August, respectively, so these months should be taken as reference for sizing thermal building systems, in Bucharest, under clear sky conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkler, Jon; Booten, Chuck
Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity.more » The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.« less
Static and Dynamic Analysis in Design of Exoskeleton Structure
NASA Astrophysics Data System (ADS)
Ivánkova, Ol'ga; Méri, Dávid; Vojteková, Eva
2017-10-01
This paper introduces a numerical experiment of creating the load bearing system of a high rise building. When designing the high-rise building, it is always an important task to find the right proportion between the height of the building and its perceptive width from the various angles of street view. Investigated high rise building in this article was designed according to these criteria. The load bearing structure of the analysed object consists of a reinforced core, plates and steel tubes of an exoskeleton. Eight models of the building were created using the spatial variant of FEM in Scia Engineer Software. Individual models varied in number and dimensions of diagrids in the exoskeleton. In the models, loadings due to the own weight, weight of external glass cladding, and due to the wind according to the Standard, have been considered. The building was loaded by wind load from all four main directions with respect to its shape. Wind load was calculated using the 3D wind generator, which is a part of the Scia Engineer Software. For each model the static analysis was performed. Its most important criterion was the maximum or minimum horizontal displacement (rotation) of the highest point of the building. This displacement was compared with the limit values of the displacement of the analysed high-rise building. By step-by-step adding diagrids and optimizing their dimensions the building model was obtained that complied with the criteria of the Limit Serviceability State. The last model building was assessed also for the Ultimate Limit State. This model was loaded also by seismic loads for comparison with the load due to the wind.
Recovery Act. Advanced Load Identification and Management for Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Yi; Casey, Patrick; Du, Liang
2014-02-12
In response to the U.S. Department of Energy (DoE)’s goal of achieving market ready, net-zero energy residential and commercial buildings by 2020 and 2025, Eaton partnered with the Department of Energy’s National Renewable Energy Laboratory (NREL) and Georgia Institute of Technology to develop an intelligent load identification and management technology enabled by a novel “smart power strip” to provide critical intelligence and information to improve the capability and functionality of building load analysis and building power management systems. Buildings account for 41% of the energy consumption in the United States, significantly more than either transportation or industrial. Within the buildingmore » sector, plug loads account for a significant portion of energy consumption. Plug load consumes 15-20% of building energy on average. As building managers implement aggressive energy conservation measures, the proportion of plug load energy can increase to as much as 50% of building energy leaving plug loads as the largest remaining single source of energy consumption. This project focused on addressing plug-in load control and management to further improve building energy efficiency accomplished through effective load identification. The execution of the project falls into the following three major aspects; An intelligent load modeling, identification and prediction technology was developed to automatically determine the type, energy consumption, power quality, operation status and performance status of plug-in loads, using electric waveforms at a power outlet level. This project demonstrated the effectiveness of the developed technology through a large set of plug-in loads measurements and testing; A novel “Smart Power Strip (SPS) / Receptacle” prototype was developed to act as a vehicle to demonstrate the feasibility of load identification technology as a low-cost, embedded solution; and Market environment for plug-in load control and management solutions, in particular, advanced power strips (APSs) was studied. The project evaluated the market potential for Smart Power Strips (SPSs) with load identification and the likely impact of a load identification feature on APS adoption and effectiveness. The project also identified other success factors required for widespread APS adoption and market acceptance. Even though the developed technology is applicable for both residential and commercial buildings, this project is focused on effective plug-in load control and management for commercial buildings, accomplished through effective load identification. The project has completed Smart Receptacle (SR) prototype development with integration of Load ID, Control/Management, WiFi communication, and Web Service. Twenty SR units were built, tested, and demonstrated in the Eaton lab; eight SR units were tested in the National Renewable Energy Lab (NREL) for one-month of field testing. Load ID algorithm testing for extended load sets was conducted within the Eaton facility and at local university campuses. This report is to summarize the major achievements, activities, and outcomes under the execution of the project.« less
24 CFR 200.925b - Residential and institutional building code comparison items.
Code of Federal Regulations, 2014 CFR
2014-04-01
...); (6) Individual unit smoke detectors; (7) Building alarm systems; (8) Highrise criteria; (b) Light and...) Design live loads; (2) Design dead loads; (3) Snow loads; (4) Wind loads. (5) Earthquake loads (in...
24 CFR 200.925b - Residential and institutional building code comparison items.
Code of Federal Regulations, 2012 CFR
2012-04-01
...); (6) Individual unit smoke detectors; (7) Building alarm systems; (8) Highrise criteria; (b) Light and...) Design live loads; (2) Design dead loads; (3) Snow loads; (4) Wind loads. (5) Earthquake loads (in...
24 CFR 200.925b - Residential and institutional building code comparison items.
Code of Federal Regulations, 2013 CFR
2013-04-01
...); (6) Individual unit smoke detectors; (7) Building alarm systems; (8) Highrise criteria; (b) Light and...) Design live loads; (2) Design dead loads; (3) Snow loads; (4) Wind loads. (5) Earthquake loads (in...
Termites utilise clay to build structural supports and so increase foraging resources
Oberst, Sebastian; Lai, Joseph C. S.; Evans, Theodore A.
2016-01-01
Many termite species use clay to build foraging galleries and mound-nests. In some cases clay is placed within excavations of their wooden food, such as living trees or timber in buildings; however the purpose for this clay is unclear. We tested the hypotheses that termites can identify load bearing wood, and that they use clay to provide mechanical support of the load and thus allow them to eat the wood. In field and laboratory experiments, we show that the lower termite Coptotermes acinaciformis, the most basal species to build a mound-nest, can distinguish unloaded from loaded wood, and use clay differently when eating each type. The termites target unloaded wood preferentially, and use thin clay sheeting to camouflage themselves while eating the unloaded wood. The termites attack loaded wood secondarily, and build thick, load-bearing clay walls when they do. The termites add clay and build thicker walls as the load-bearing wood is consumed. The use of clay to support wood under load unlocks otherwise unavailable food resources. This behaviour may represent an evolutionary step from foraging behaviour to nest building in lower termites. PMID:26854187
Selecting a Control Strategy for Plug and Process Loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lobato, C.; Sheppy, M.; Brackney, L.
2012-09-01
Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the designmore » and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.« less
Structural evaluation of the 2736Z Building for seismic loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giller, R.A.
The 2736Z building structure is evaluated for high-hazard loads. The 2736Z building is analyzed herein for normal and seismic loads and is found to successfully meet the guidelines of UCRL-15910 along with the related codes requirements.
50th Annual Fuze Conference.Session 3 and 4
2006-05-11
Exploding Foil Initiator Research • Research on Explosives • Conclusion Wim Prinse Research Scientist3 TNO has organised...Research Scientist6 Exploding Foil Initiator Research • Electrical circuit • Exploding foil • Velocity of the flyer • Driver Explosive • Secondary...90% efficiency of energy deposited in the exploding foil (50 % other circuits) Wim Prinse Research Scientist8 Exploding foil • Dimension of the foil
Annual Fuze Conference and Munitions Technology Symposium VI (43rd)
1999-04-07
part manufacture and assembly and identify the parameters that we must control through production. Analyzing the coefficients of variation and the...processing energetic materials. The extruder is equipped with four independent temperature control zones, segmented screws, a jacketed die block capable of...and has vacuum capability. Data monitoring capabilities include melt temperature and pressure, torque, screw speed, and temperatures in all of the
2005 Precision Strike Annual Programs Review
2005-04-20
Control Canards (4) Polyurethane Foam Support DPICM (404 M101 Grenades) Warhead Fuze: Electronic Safe & Arm Device (ESAD) UNCLASSIFIED UNCLASSIFIED PF...SYSTEMS: • JASSM: Colonel James Geurts, USAF JASSM PM • ATACMS : Colonel Earnest Harris, USA PM, Precision Fires Rockets & Missiles, PEO Space and...UNCLASSIFIED UNCLASSIFIED Viper Strike Lineage ATACMS Delivered Base BATs Viper Strike SAL Seeker Proof of Principle Demos I & II Hunter-Viper Strike
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This appendix summarizes building characteristics used to determine heating and cooling loads for each of the five building types in each of the four regions. For the selected five buildings, the following data are attached: new and existing construction characteristics; new and existing construction thermal resistance; floor plan and elevation; people load schedule; lighting load schedule; appliance load schedule; ventilation schedule; and hot water use schedule. For the five building types (single family, apartment buildings, commercial buildings, office buildings, and schools), data are compiled in 10 appendices. These are Building Characteristics; Alternate Energy Sources and Energy Conservation Techniques Description, Costs,more » Fuel Price Scenarios; Life Cycle Cost Model; Simulation Models; Solar Heating/Cooling System; Condensed Weather; Single and Multi-Family Dwelling Characteristics and Energy Conservation Techniques; Mixed Strategies for Energy Conservation and Alternative Energy Utilization in Buildings. An extensive bibliography is given in the final appendix. (MCW)« less
Physical and JIT Model Based Hybrid Modeling Approach for Building Thermal Load Prediction
NASA Astrophysics Data System (ADS)
Iino, Yutaka; Murai, Masahiko; Murayama, Dai; Motoyama, Ichiro
Energy conservation in building fields is one of the key issues in environmental point of view as well as that of industrial, transportation and residential fields. The half of the total energy consumption in a building is occupied by HVAC (Heating, Ventilating and Air Conditioning) systems. In order to realize energy conservation of HVAC system, a thermal load prediction model for building is required. This paper propose a hybrid modeling approach with physical and Just-in-Time (JIT) model for building thermal load prediction. The proposed method has features and benefits such as, (1) it is applicable to the case in which past operation data for load prediction model learning is poor, (2) it has a self checking function, which always supervises if the data driven load prediction and the physical based one are consistent or not, so it can find if something is wrong in load prediction procedure, (3) it has ability to adjust load prediction in real-time against sudden change of model parameters and environmental conditions. The proposed method is evaluated with real operation data of an existing building, and the improvement of load prediction performance is illustrated.
14. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), ...
14. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), LOOKING EAST AT SOUTHWEST END OF BUILDING. HVAC EQUIPMENT LOCATED OUTDOORS IN FOREGROUND. DUCTS CONDUCT HOT OR COLD AIR INDOORS. ROUND PIPES ARE INSULATED STEAM LINES. BUILDING NO. 448, ORDNANCE FACILITY, IN BACKGROUND. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
2. General oblique view of north loading dock showing loading ...
2. General oblique view of north loading dock showing loading docks with doors opening into refrigerated rooms - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX
Structural analysis for a 40-story building
NASA Technical Reports Server (NTRS)
Hua, L.
1972-01-01
NASTRAN was chosen as the principal analytical tool for structural analysis of the Illinois Center Plaza Hotel Building in Chicago, Illinois. The building is a 40-story, reinforced concrete structure utilizing a monolithic slab-column system. The displacements, member stresses, and foundation loads due to wind load, live load, and dead load were obtained through a series of NASTRAN runs. These analyses and the input technique are described.
11. GENERAL VIEW LOOKING NORTHEAST, BUILDING NO. 823, AMMUNITIOM NITRATE ...
11. GENERAL VIEW LOOKING NORTHEAST, BUILDING NO. 823, AMMUNITIOM NITRATE LOADING BUILDING, IN LEFT BACKGROUND. BUILDING NO. 824, TNT SCREENING BUILDING, IN RIGHT BACKGROUND. - Picatinny Arsenal, 800 Area, Complete Rounds-Melt Loading District, State Route 15 near I-80, Dover, Morris County, NJ
Shear-lag effect and its effect on the design of high-rise buildings
NASA Astrophysics Data System (ADS)
Thanh Dat, Bui; Traykov, Alexander; Traykova, Marina
2018-03-01
For super high-rise buildings, the analysis and selection of suitable structural solutions are very important. The structure has not only to carry the gravity loads (self-weight, live load, etc.), but also to resist lateral loads (wind and earthquake loads). As the buildings become taller, the demand on different structural systems dramatically increases. The article considers the division of the structural systems of tall buildings into two main categories - interior structures for which the major part of the lateral load resisting system is located within the interior of the building, and exterior structures for which the major part of the lateral load resisting system is located at the building perimeter. The basic types of each of the main structural categories are described. In particular, the framed tube structures, which belong to the second main category of exterior structures, seem to be very efficient. That type of structure system allows tall buildings resist the lateral loads. However, those tube systems are affected by shear lag effect - a nonlinear distribution of stresses across the sides of the section, which is commonly found in box girders under lateral loads. Based on a numerical example, some general conclusions for the influence of the shear-lag effect on frequencies, periods, distribution and variation of the magnitude of the internal forces in the structure are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sowell, E.
1979-06-01
The Building Loads Analysis and System Thermodynamics (BLAST) program is a comprehensive set of subprograms for predicting energy consumption in buildings. There are three major subprograms: (1) the space load predicting subprogram, which computes hourly space loads in a building or zone based on user input and hourly weather data; (2) the air distribution system simulation subprogram, which uses the computed space load and user inputs describing the building air-handling system to calculate hot water or steam, chilled water, and electric energy demands; and (3) the central plant simulation program, which simulates boilers, chillers, onsite power generating equipment and solarmore » energy systems and computes monthly and annual fuel and electrical power consumption and plant life cycle cost.« less
NASA Astrophysics Data System (ADS)
Heidarinejad, Mohammad
This dissertation develops rapid and accurate building energy simulations based on a building classification that identifies and focuses modeling efforts on most significant heat transfer processes. The building classification identifies energy use patterns and their contributing parameters for a portfolio of buildings. The dissertation hypothesis is "Building classification can provide minimal required inputs for rapid and accurate energy simulations for a large number of buildings". The critical literature review indicated there is lack of studies to (1) Consider synoptic point of view rather than the case study approach, (2) Analyze influence of different granularities of energy use, (3) Identify key variables based on the heat transfer processes, and (4) Automate the procedure to quantify model complexity with accuracy. Therefore, three dissertation objectives are designed to test out the dissertation hypothesis: (1) Develop different classes of buildings based on their energy use patterns, (2) Develop different building energy simulation approaches for the identified classes of buildings to quantify tradeoffs between model accuracy and complexity, (3) Demonstrate building simulation approaches for case studies. Penn State's and Harvard's campus buildings as well as high performance LEED NC office buildings are test beds for this study to develop different classes of buildings. The campus buildings include detailed chilled water, electricity, and steam data, enabling to classify buildings into externally-load, internally-load, or mixed-load dominated. The energy use of the internally-load buildings is primarily a function of the internal loads and their schedules. Externally-load dominated buildings tend to have an energy use pattern that is a function of building construction materials and outdoor weather conditions. However, most of the commercial medium-sized office buildings have a mixed-load pattern, meaning the HVAC system and operation schedule dictate the indoor condition regardless of the contribution of internal and external loads. To deploy the methodology to another portfolio of buildings, simulated LEED NC office buildings are selected. The advantage of this approach is to isolate energy performance due to inherent building characteristics and location, rather than operational and maintenance factors that can contribute to significant variation in building energy use. A framework for detailed building energy databases with annual energy end-uses is developed to select variables and omit outliers. The results show that the high performance office buildings are internally-load dominated with existence of three different clusters of low-intensity, medium-intensity, and high-intensity energy use pattern for the reviewed office buildings. Low-intensity cluster buildings benefit from small building area, while the medium- and high-intensity clusters have a similar range of floor areas and different energy use intensities. Half of the energy use in the low-intensity buildings is associated with the internal loads, such as lighting and plug loads, indicating that there are opportunities to save energy by using lighting or plug load management systems. A comparison between the frameworks developed for the campus buildings and LEED NC office buildings indicates these two frameworks are complementary to each other. Availability of the information has yielded to two different procedures, suggesting future studies for a portfolio of buildings such as city benchmarking and disclosure ordinance should collect and disclose minimal required inputs suggested by this study with the minimum level of monthly energy consumption granularity. This dissertation developed automated methods using the OpenStudio API (Application Programing Interface) to create energy models based on the building class. ASHRAE Guideline 14 defines well-accepted criteria to measure accuracy of energy simulations; however, there is no well-accepted methodology to quantify the model complexity without the influence of the energy modeler judgment about the model complexity. This study developed a novel method using two weighting factors, including weighting factors based on (1) computational time and (2) easiness of on-site data collection, to measure complexity of the energy models. Therefore, this dissertation enables measurement of both model complexity and accuracy as well as assessment of the inherent tradeoffs between energy simulation model complexity and accuracy. The results of this methodology suggest for most of the internal load contributors such as operation schedules the on-site data collection adds more complexity to the model compared to the computational time. Overall, this study provided specific data on tradeoffs between accuracy and model complexity that points to critical inputs for different building classes, rather than an increase in the volume and detail of model inputs as the current research and consulting practice indicates. (Abstract shortened by UMI.).
Influence of Loads That Are Not Contemplated In the Structure Calculation Process
NASA Astrophysics Data System (ADS)
Gil Carrillo, Francisco; José Mas-Guindal, Antonio
2017-10-01
The approach to the calculation of the structure of a building, apart from the geometry and its peculiarities always in the first instance, the first approach is to analyze the state of loads, according to current legislation CTE, to which the building will be subjected and In their respective plants and areas, these loads are defined in any of the regulations in force at the moment in Spain and almost all the professionals of the sector known for their application. In addition to the loads described above, there are others that intervene in the building, although they are evident only during the execution phase of the building, those loads that are forgotten and not taken into account, nor even the existing mandatory regulations CTE, EHE-08, in that first approach of load state for the calculation of the structure of the building, are there and have their direct consequences on the structure, ultimately on the useful life of the structure and the interaction with The rest of the elements that make up the building can cause instantaneous pathologies, medium and long term in the structures and consequently in the rest of the building with the effects derived from them.
UXO Live Site Classification Demonstrations: A Retrospective Summary
2017-10-01
performance ROC Curve Number of True Clutter Incorrectly Classified TO I R em ed ia tio n: Pe rc en t o f T ru e TO I Co rr ec tly C la ss ifi ed...rocket, 382 practice bomb , M103 bomb nose fuze, 100lb bomb , M1 practice bomb MPV, TEMTADS 2x2 2014 Waikoloa Waikoloa, HI 9 small ISO, 37mm, medium
2008 Munitions Executive Summit
2008-02-21
7:00pm Hosted Reception 2008 Munitions Executive Summit February 20, 2008 – AGENDA (cont.) 8:00am Administrative Remarks 8:05am PEO Keynote Address...MES Awards Tuesday, February 19 5pm Reception /Pre-registration Sponsored by ATK Ammunition Systems Group and Kaman Aerospace’s Fuzing...15pm Adjourn 5:15pm - 7pm Hosted Reception Sponsored by DSE, Inc. and General Dynamics-OTS Munitions executive suMMit 2008 agenda & prograM
2007-05-27
5:00PM - Opening Reception 6:30PM WEDNESDAY, MAY 23, 2007 (General Session) TUESDAY, MAY 22, 2007 (Early Registration) 11:50 AM - LUNCHEON 1:00 PM... RECEPTION 7:00 PM WEDNESDAY, MAY 23, 2007 (Parallel Sessions) Session IVA - OPEN SESSION Chair: Mr. Telly Manolatos, Electronics Development Corporation...company’s logo in the agenda handouts and proceedings o Signage outside the particular event sponsored o Sponsor ribbon on badges • Reception - $8,000
Air Bursting Munition ABM Medium Calibre Applications
2001-04-18
NDIA 45th Annual Fuze Conference - Long Beach, CA - April 16-18, 2001 Folie 1 P2 15548 BB, P-VP/FD/11, © 2001 Oerlikon Contraves AG, Zürich...Switzerland Air Bursting Munition ABM Medium Calibre Applications Allan Buckley & Pierre Freymond Oerlikon Contraves Pyrotec AG CH-8050 Zurich...Project Number Task Number Work Unit Number Performing Organization Name(s) and Address(es) Oerlikon Contraves Pyrotec AG CH-8050 Zurich / Switzerland
National Radar Conference, Los Angeles, CA, March 12, 13, 1986, Proceedings
NASA Astrophysics Data System (ADS)
The topics discussed include radar systems, radar subsystems, and radar signal processing. Papers are presented on millimeter wave radar for proximity fuzing of smart munitions, a solid state low pulse power ground surveillance radar, and the Radarsat prototype synthetic-aperture radar signal processor. Consideration is also given to automatic track quality assessment in ADT radar systems instrumentation of RCS measurements of modulation spectra of aircraft blades.
Aircraft Survivability. Spring 2011
2011-01-01
test Figure 4 Mixed Lagrangian and SPH Simulation of the Bullet Impacting the Floor Section Figure 5 Predictions of Damage to Penetrator, CMC Layer...aircraft and regulating the flow of liquid to simulate both the intrinsic change in plume intensity and the apparent change in intensity of a simulated ...the development of a digital simulation to conduct end game studies of the Eagle missile warhead- fuze combination. This was one of the first
Director, Operational Test and Evaluation FY 2004 Annual Report
2004-01-01
HIGH) Space Based Radar (SBR) Sensor Fuzed Weapon (SFW) P3I (CBU-97/B) Small Diameter Bomb (SDB) Secure Mobile Anti-Jam Reliable Tactical Terminal...detection, identification, and sampling capability for both fixed-site and mobile operations. The system must automatically detect and identify up to ten...staffing within the Services. SYSTEM DESCRIPTION AND MISSION The Services envision JCAD as a hand-held device that automatically detects, identifies, and
Feasibility of Standardized Rain Testing for Fuzes. Serial Number 1.0
1981-06-01
produced by ;he drops in a small volume with a laser beam. /, -- Il 8’ 15 -. - II11,, I - - Il i Io " illli A pr c i / con3 1de at o Is sh ll d o u d r...of collapse of the spherical bubbles in an asymmetric mode such that hlqh velocity microjets impinqe on the surface. It appears cavitation microjet
A Reactor Development Scenario for the FuZE Sheared-Flow Stabilized Z-pinch
NASA Astrophysics Data System (ADS)
McLean, Harry S.; Higginson, D. P.; Schmidt, A.; Tummel, K. K.; Shumlak, U.; Nelson, B. A.; Claveau, E. L.; Forbes, E. G.; Golingo, R. P.; Stepanov, A. D.; Weber, T. R.; Zhang, Y.
2017-10-01
We present a conceptual design, scaling calculations, and development path for a pulsed fusion reactor based on a flow-stabilized Z-pinch. Experiments performed on the ZaP and ZaP-HD devices have largely demonstrated the basic physics of sheared-flow stabilization at pinch currents up to 100 kA. Initial experiments on the FuZE device, a high-power upgrade of ZaP, have achieved 20 usec of stability at pinch current 100-200 kA and pinch diameter few mm for a pinch length of 50 cm. Scaling calculations based on a quasi-steady-state power balance show that extending stable duration to 100 usec at a pinch current of 1.5 MA and pinch length of 50 cm, results in a reactor plant Q 5. Future performance milestones are proposed for pinch currents of: 300 kA, where Te and Ti are calculated to exceed 1-2 keV; 700 kA, where DT fusion power would be expected to exceed pinch input power; and 1 MA, where fusion energy per pulse exceeds input energy per pulse. This work funded by USDOE ARPA-E and performed under the auspices of Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-734770.
Simulation of probabilistic wind loads and building analysis
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Chamis, Christos C.
1991-01-01
Probabilistic wind loads likely to occur on a structure during its design life are predicted. Described here is a suitable multifactor interactive equation (MFIE) model and its use in the Composite Load Spectra (CLS) computer program to simulate the wind pressure cumulative distribution functions on four sides of a building. The simulated probabilistic wind pressure load was applied to a building frame, and cumulative distribution functions of sway displacements and reliability against overturning were obtained using NESSUS (Numerical Evaluation of Stochastic Structure Under Stress), a stochastic finite element computer code. The geometry of the building and the properties of building members were also considered as random in the NESSUS analysis. The uncertainties of wind pressure, building geometry, and member section property were qualified in terms of their respective sensitivities on the structural response.
Loads specification and embedded plate definition for the ITER cryoline system
NASA Astrophysics Data System (ADS)
Badgujar, S.; Benkheira, L.; Chalifour, M.; Forgeas, A.; Shah, N.; Vaghela, H.; Sarkar, B.
2015-12-01
ITER cryolines (CLs) are complex network of vacuum-insulated multi and single process pipe lines, distributed in three different areas at ITER site. The CLs will support different operating loads during the machine life-time; either considered as nominal, occasional or exceptional. The major loads, which form the design basis are inertial, pressure, temperature, assembly, magnetic, snow, wind, enforced relative displacement and are put together in loads specification. Based on the defined load combinations, conceptual estimation of reaction loads have been carried out for the lines located inside the Tokamak building. Adequate numbers of embedded plates (EPs) per line have been defined and integrated in the building design. The finalization of building EPs to support the lines, before the detailed design, is one of the major design challenges as the usual logic of the design may alter. At the ITER project level, it was important to finalize EPs to allow adequate design and timely availability of the Tokamak building. The paper describes the single loads, load combinations considered in load specification and the approach for conceptual load estimation and selection of EPs for Toroidal Field (TF) Cryoline as an example by converting the load combinations in two main load categories; pressure and seismic.
Solar-Energy System for a Commercial Building--Topeka, Kansas
NASA Technical Reports Server (NTRS)
1982-01-01
Report describes a solar-energy system for space heating, cooling and domestic hot water at a 5,600 square-foot (520-square-meter) Topeka, Kansas, commercial building. System is expected to provide 74% of annual cooling load, 47% of heating load, and 95% of domestic hot-water load. System was included in building design to maximize energy conservation.
Standardization of a Safing and Arming Device for Artillery Ammunition
1976-10-01
designated by other author- ized documents. UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE (When Dala Entered) REPORT DOCUMENTATION PAGE READ...establish the physical and military requirements. Design studies were initiated on the current S&A devices. • DD FOR’* •’*• 1 JAN 73 1473...A developer. In the design of any mechanism, a precise definition of S&A requirements for all fuze applications is required prior to development
An Organizational Analysis Model for Navy Field-Level Comptrollership.
1980-09-01
organization with some self -control despite interdepen- dence with the environment. But if we are to gain understanding, we must consider both in the...involve a self -protective reaction. The short time fuze allows the decision to be made without outside input or approval. The following discussion will...no real standard ways of running a Comptroller Department. 51. Establishment of self with C.O. and department heads. 52. Learning the underlying
A Shotline Method for Modeling Projectile Geometry
1986-06-01
by block number) GIFT Target Description Vulnerability Analysis COMGEOM Shotlining Warhead Lethality MISFIR 20. ABSTRACT fConfteue an r»r»r«» eUm It rt...target interaction is centered upon the program MISFIR, written in CDC Fortran 5. MISFIR is built on the formalisms of the GIFT (Geometric...a ray-tracing subroutine added to GIFT (viz. SHOTCYL); MISFIR itself, together with its subprograms; and an application program, called FUZES, which
50th Annual Fuze Conference Sessions 3 and 4 Held in Norfolk, Virginia on May 9-11, 2006
2006-05-11
Exploding Foil Initiator Research • Research on Explosives • Conclusion Wim Prinse Research Scientist3 TNO has organised...Research Scientist6 Exploding Foil Initiator Research • Electrical circuit • Exploding foil • Velocity of the flyer • Driver Explosive • Secondary...90% efficiency of energy deposited in the exploding foil (50 % other circuits) Wim Prinse Research Scientist8 Exploding foil • Dimension of the foil
15. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), ...
15. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), INTERIOR, FOURTH LEVEL. POWDER HOPPER AT TOP OF ELEVATOR SHAFT. POWDER DISTRIBUTED FROM HERE TO LOADING ROOMS BY TUBES. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
NASA Astrophysics Data System (ADS)
Yagi Kim, Mika
As building envelopes have improved due to more restrictive energy codes, internal loads have increased largely due to the proliferation of computers, electronics, appliances, imaging and audio visual equipment that continues to grow in commercial buildings. As the dependency on the internet for information and data transfer increases, the electricity demand will pose a challenge to design and operate Net Zero Energy Buildings (NZEBs). Plug Loads (PLs) as a proportion of the building load has become the largest non-regulated building energy load and represents the third highest electricity end-use in California's commercial office buildings, accounting for 23% of the total building electricity consumption (Ecova 2011,2). In the Annual Energy Outlook 2008 (AEO2008), prepared by the Energy Information Administration (EIA) that presents long-term projections of energy supply and demand through 2030 states that office equipment and personal computers are the "fastest growing electrical end uses" in the commercial sector. This thesis entitled "Watts Per Person" Paradigm to Design Net Zero Energy Buildings, measures the implementation of advanced controls and behavioral interventions to study the reduction of PL energy use in the commercial sector. By integrating real world data extracted from an energy efficient commercial building of its energy use, the results produce a new methodology on estimating PL energy use by calculating based on "Watts Per Person" and analyzes computational simulation methods to design NZEBs.
Retail Buildings: Assessing and Reducing Plug and Process Loads in Retail Buildings (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2013-04-01
Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly large fraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use inmore » retail spaces are poorly understood.« less
Solar-heated and cooled savings and loan building-1-Leavenworth, Kanasas
NASA Technical Reports Server (NTRS)
1981-01-01
Report describes heating and cooling system which furnishes 90 percent of annual heating load, 70 percent of cooling load, and all hot water for two-story building. Roof-mounted flat-plate collectors allow three distinct flow rates and are oriented south for optimum energy collection. Building contains fully automated temperature controls is divided into five temperature-load zones, each with independent heat pump.
Engaging Tenants in Reducing Plug Load Energy Use
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schantz, Marta; Langner, Rois
Plug and Process Loads (PPLs) account for an increasingly large percentage of commercial building energy use in the U.S. due to the rising number of energy intensive plug-in devices. In addition, buildings are becoming more and more efficient and plug load energy use has become an increasingly pertinent component to achieving aggressive energy targets and netzero energy status. For multi-tenant buildings, controlling plug loads in tenant spaces can be a significant challenge. Luckily, there are a number of PPL reduction strategies, best practices, and lessons learned from numerous commercial real estate and higher education leaders who have successfully engaged buildingmore » occupants and tenants in reducing PPL energy use. This paper provides actionable PPL reduction strategies and best practices that building owners and managers can immediately apply to their own buildings.« less
A Summary Report on Store Heating Technology
1978-09-01
from aerodynamic heating effects. Almost all present-day bombs and fuzes have, as their explosive charge, some form of TNT which melts at about 178...deg. This was achieved on flights 14, 16, 18, 19, and 20. Flight 15 was a subsonic mission to perform afterburner tests, and flight 17 was aborted...BDU-12 at a Mach number of 2.5. Of course, this store did not contain TNT and was in no way restricted by the temperature limitations previously
Operation of the Chemical Agent Munitions Disposal System (CAMDS) at Tooele Army Depot, Utah.
1978-09-01
parts furnace where the container is opened to expose the agent; the agent is boiled out and burned ; and the residual container is heat treated for...fuze booster to expose the booster pellet so it will burn instead of detonate in the Deactivation Furnace. A portion of the solution in the coolant...demilitarization equipment exposed to agent GB will be chemically decontaminated to prepare for operations with burstered mustard projectiles. The
US Army battery needs -- Present and future
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamlen, R.P.; Christopher, H.A.; Gilman, S.
1995-07-01
The purpose of this paper is to describe the needs of the US Army for silent portable power sources, both in the near and longer term future. As a means of doing this, the programs of the Power Sources Division of the Army Research Laboratory will be discussed. The six program areas in which the Power Sources Division is engaged are: primary batteries, rechargeable batteries, reserve/fuze batteries, pulse batteries and capacitors, fuel cells, and thermophotovoltaic power generation.
2009-09-22
test officer). At a minimum, the CIL will be conducted at the operator level (often referred to as “field strip and clean”). More detailed...is checked before each shot is fired. Use a boresight (optical or laser ) as necessary to check alignment to the target aiming point if the barrel is...for this test should be representative of production. All components must be present, including projectile paint and markings, fuzes, any tool
2014-09-01
elements of functional structure. Frequently the requirement for this is to ensure long- term retention of skilled people through the provision of an...operational and manufacturable, greatly reducing the design work remaining for Milestone C. 14. SUBJECT TERMS System Architecture, manufacturing...specialized ammunition technology item such as a fuze takes too long, from initial concept through final production design, which is approved for
Production Methodology for the Validation of Electronic Fuzes
1980-11-01
are employed age cantridge o; magazine This mud’e is shown in figure Vtll-t (f) Fxtensis’e debuggngij and troubleshooting to perfect the automatic...All the plastic manterials platens The heat is supplied bs steam, heated can be fabricated b% more than one methoid , al- liquids, electrical res.stance...on-I-ne data bases, or the real-time data acquisition Resources %%ill be performizble- Thus. tbe adsantages that cook ;i be realized by full use of
16. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), ...
16. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), INTERIOR, SECOND LEVEL. LOOKING UP AT POWDER AND DISTRIBUTION TUBES. ELEVATOR SHAFT ON LEFT. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
5. LOOKING NORTH TOWARD BARRICADES AROUND BUILDING NO. 230, PRIMER ...
5. LOOKING NORTH TOWARD BARRICADES AROUND BUILDING NO. 230, PRIMER AND DETONATOR LOADING BUILDING. BARRICADES DIRECT FORCE OF BLAST UPWARD IN THE EVENT OF AN EXPLOSION. - Picatinny Arsenal, 200 Area, Shell Component Loading, State Route 15 near I-80, Dover, Morris County, NJ
Plug-Load Control and Behavioral Change Research in GSA Office Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Metzger, I.; Cutler, D.; Sheppy, M.
2012-10-01
The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-loadmore » energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.« less
Sonic-boom-induced building structure responses including damage.
NASA Technical Reports Server (NTRS)
Clarkson, B. L.; Mayes, W. H.
1972-01-01
Concepts of sonic-boom pressure loading of building structures and the associated responses are reviewed, and results of pertinent theoretical and experimental research programs are summarized. The significance of sonic-boom load time histories, including waveshape effects, are illustrated with the aid of simple structural elements such as beams and plates. Also included are discussions of the significance of such other phenomena as three-dimensional loading effects, air cavity coupling, multimodal responses, and structural nonlinearities. Measured deflection, acceleration, and strain data from laboratory models and full-scale building tests are summarized, and these data are compared, where possible, with predicted values. Damage complaint and claim experience due both to controlled and uncontrolled supersonic flights over communities are summarized with particular reference to residential, commercial, and historic buildings. Sonic-boom-induced building responses are compared with those from other impulsive loadings due to natural and cultural events and from laboratory simulation tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanford, J.W.; Huang, Y.J.
The energy performance of skylights is similar to that of windows in admitting solar heat gain, while at the same time providing a pathway for convective and conductive heat transfer through the building envelope. Since skylights are typically installed at angles ranging from 0{degrees} to 45{degrees}, and differ from windows in both their construction and operation, their conductive and convective heat gains or losses, as well as solar heat gain, will differ for the same rough opening and thermal characteristics. The objective of this work is to quantify the impact of solar gain through skylights on building heating and coolingmore » loads in 45 climates, and to develop a method for including these data into the SP53 residential loads data base previously developed by LBL in support of DOE`s Automated Residential Energy Standard (ARES) program. The authors used the DOE-2.1C program to simulate the heating and cooling loads of a prototypical residential building while varying the size and solar characteristics of skylights and windows. The results are presented as Skylight Solar Loads, which are the contribution of solar gains through skylights to the overall building heating and cooling loads, and as Skylight Solar Load Ratios, which are the ratios of skylight solar loads to those for windows with the same orientation. The study shows that skylight solar loads are larger than those for windows in both heating and cooling. Skylight solar cooling loads are from three to four times greater than those for windows regardless of the skylight tilt, except for those facing north. These cooling loads are largest for south-facing skylights at a tilt angle of approximately 20{degrees}, and drop off at higher tilts and other orientations.« less
29 CFR 1910.22 - General requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading.... (d) Floor loading protection. (1) In every building or other structure, or part thereof, used for... roof of a building or other structure a load greater than that for which such floor or roof is approved...
29 CFR 1910.22 - General requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading.... (d) Floor loading protection. (1) In every building or other structure, or part thereof, used for... roof of a building or other structure a load greater than that for which such floor or roof is approved...
29 CFR 1910.22 - General requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading.... (d) Floor loading protection. (1) In every building or other structure, or part thereof, used for... roof of a building or other structure a load greater than that for which such floor or roof is approved...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1 The systems...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1The systems...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1The systems...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1The systems...
MineWolf Tiller Test and Evaluation
2007-11-01
scale. Reheat and reweigh until no change in mass is recorded. Soil is then dry. Calculations The moisture content of a soil is expressed as a... MOISTURE % WET DENSITY KG/M³ DRY DENSITY KG/M³ 1 07-Sep-06 gravel 10cm 4 2731 2621 2 07-Sep-06 gravel 10cm 4 2653 2541 3 07-Sep-06 gravel 10cm 3...each soil condition. This table also indicates the number of untriggered fuzes which were found separated from their main charges. The notes
Cost-Reduced M587 Electronic Time Fuze: Root Cause Analysis of July 1979 Early Bursts
1981-04-01
capacitor during gunfire, coupled with an intermit - tent wire bond (which opens during setback and then closes again) can defeat the initialization circuit...is calibrated, (c) the set time is checked out in fast time to verify that the setting has actually been achieved, and (d) the setter visually com...insensitive to supply voltage. One of the reasons for choosing the twin-T design was because it was possible to preclude fail- fast failure modes. The
Annual Fuze Conference (54th) Held in Kansas City, Missouri on May 11-13, 2010
2010-05-13
approaches to development • Lets get something straight !!! – Experimentation (A few of a kind) • Focus on answering questions (is it useful?, how does it...machines are applicable / available • How do the machines work • Where do they get their reference • What kind of tolerances are they capable of...Tactical Benefits: • Fastest way to get local reconnaissance images • Totally impervious to weather/gusts • ~ $20/round Background History New
Linear Theory of a Projectile With a Rotating Internal Part in Atmospheric Flight
2003-07-01
shape, or form. Fuze mechanisms used on some indirect fire ammunition employ a rotor that is permitted to move slightly with respect to the main...series of experiments where a projectile with a loose internal part was driven by the rotor of a freely gimbaled gyroscope. The gyroscope yaw history...cases, weapon system designers require guidance on the effect of the rotating internal part as well as guidance on how to optimally configure such a
1982-11-30
the cost of an alternate signal set: - Power - Bidirectional data link (point-to-point) (plus store receptacle or induction coil) b. FUNCTION...digital fuzes had been implemented. The first presentation described an inductive data link for surface launched projectiles which sent both power and...AD-A130 681 MINUTES OF FSC 5935 CONNECTOR STANDARDIZATION PLANNING 1/2 MEETING HELD AT DAYTON OHIO ON 25-27 AUGUST 1982WU) DEFENSE ELECTRONICS SUPPLY
High Temperature/Solar Effects Testing on Various Munitions
1992-08-01
days. Follming conditioning, a variety of laboratory and ballistic tests are performed t o assess safety and performame. The test i t e m s are...ranging from 60-mm cartridges to 8-inch projectiles. anununition types including fuzes and anti-tank rockets. The first phase w a s conducted from...container with a foam liner. Each cartridge w a s in its individual fiber Each cartridge was packed in a fiber cartridge, 120-nun: APFSRS-T, M829Al
Study of Damped Set-Back Pins for S and A Mechanisms.
1976-11-01
arm device for artillery munitions. This damped set-back pin assembly is one of two safety features on a S and A device used in the M739 PD/XM587 ET...The damped set-back pin study program was for the design, testing, fabrication, and delivery and damped set-back pin assemblies for use in a safe and...fuzes for a rotating projectile. A pin, porous disc, return spring, floating O-ring, and sleeve comprise the selected damped set-back pin assembly
The Coast Artillery Journal. Volume 57, Number 3, September 1922
1922-09-01
program is available here. The big games are basket-ball and baseball. The Army and Xavy have a fine baseball league. Rugby football is popular with...Panama are largely confined to the Union and Century Clubs, also the National and Ce- cilia Theatres. The Union Club is a Panamanian club that extends...in some, has a screw thread. Fuzes of iron or copper were in use before Langside, some of them screwed. They appear to have contained a match of
German Explosive Ordnance (Projectiles and Projectile Fuzes)
1953-03-01
CAP IGNITER BRIDGE INSULATION BLACK POWDER Figure 320—Electric Primers c/12nA and c/22 354 PROJECTILES 0.75 inch, length of body. 0.281 inch...of lip. 0.75 inch, length of body. Number of threads, 5 RH. CONSTRUCTION. The primer houses an igniter bridge which consists of lead styphnate...dipped in gelatin. This bridge has a resistance of approxi- mately 2.2 ohms and is in the circuit with the in- sulated contact plug, the spring washer
Atmospheric Effects upon Laser Beam Propagation: An Annotated Bibliography
1979-02-14
pp. 2711-2720, September 1978. [ Measurements in long path white cell and spietro- phone using a tunable DF laser on normal and deuterium depleted...34Backscatter in Clouds at 0.9 pm and Its Effect on Optical Fuzing Systems ," Proc. 7th Laser Conf., Vol. I1, p. 15, June 1976. [ Measured extinction and...relative transmission measurements during March at the White Sands HELSTF (High Energy Laser Standard Test 12 Facility) 6.5 km path . In May they are
History of the Shaped Charge Effect: The First 100 Years
1990-03-22
patent, wave shapers, follow-through, U.S. 1949 39 6.5-in. ATAR HEAT rocket, U.S. NOTS, 1950 (schematic) 40 Test of 15-in. long standoff shaped charge...Swiss chemist Frederick Schoenbein in 1845, and nitroglycerin, derived by Ascanio Sobrero, professor of Chemistry at the University of Turin, Italy, in...totally new warhead and fuze system and delivery of the first 1000 rounds to Korea in less than 20 days! The 6.5-Inch ATAR (Code Name "RAM") The 6.5
Energy Integrated Lighting-Heating-Cooling System.
ERIC Educational Resources Information Center
Meckler, Gershon; And Others
1964-01-01
Energy balance problems in the design of office buildings are analyzed. Through the use of integrated systems utilizing dual purpose products, a controlled environment with minimum expenditure of energy, equipment and space can be provided. Contents include--(1) office building occupancy loads, (2) office building heating load analysis, (3) office…
Mitigating shear lag in tall buildings
NASA Astrophysics Data System (ADS)
Gaur, Himanshu; Goliya, Ravindra K.
2015-09-01
As the height of building increases, effect of shear lag also becomes considerable in the design of high-rise buildings. In this paper, shear lag effect in tall buildings of heights, i.e., 120, 96, 72, 48 and 36 stories of which aspect ratio ranges from 3 to 10 is studied. Tube-in-tube structural system with façade bracing is used for designing the building of height 120 story. It is found that bracing system considerably reduces the shear lag effect and hence increases the building stiffness to withstand lateral loads. Different geometric patterns of bracing system are considered. The best effective geometric configuration of bracing system is concluded in this study. Lateral force, as wind load is applied on the buildings as it is the most dominating lateral force for such heights. Wind load is set as per Indian standard code of practice IS 875 Part-3. For analysis purpose SAP 2000 software program is used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piette, Mary Ann; Kiliccote, Sila; Ghatikar, Girish
2014-08-01
The need for and concepts behind demand response are evolving. As the electric system changes with more intermittent renewable electric supply systems, there is a need to allow buildings to provide more flexible demand. This paper presents results from field studies and pilots, as well as engineering estimates of the potential capabilities of fast load responsiveness in commercial buildings. We present a sector wide analysis of flexible loads in commercial buildings, which was conducted to improve resource planning and determine which loads to evaluate in future demonstrations. These systems provide important capabilities for future transactional systems. The field analysis ismore » based on results from California, plus projects in the northwest and east coast. End-uses considered include heating, ventilation, air conditioning and lighting. The timescales of control include day-ahead, as well as day-of, 10-minute ahead and even faster response. This technology can provide DR signals on different times scales to interact with responsive building loads. We describe the latency of the control systems in the building and the round trip communications with the wholesale grid operators.« less
WASTE HANDLING BUILDING ELECTRICAL SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
S.C. Khamamkar
2000-06-23
The Waste Handling Building Electrical System performs the function of receiving, distributing, transforming, monitoring, and controlling AC and DC power to all waste handling building electrical loads. The system distributes normal electrical power to support all loads that are within the Waste Handling Building (WHB). The system also generates and distributes emergency power to support designated emergency loads within the WHB within specified time limits. The system provides the capability to transfer between normal and emergency power. The system provides emergency power via independent and physically separated distribution feeds from the normal supply. The designated emergency electrical equipment will bemore » designed to operate during and after design basis events (DBEs). The system also provides lighting, grounding, and lightning protection for the Waste Handling Building. The system is located in the Waste Handling Building System. The system consists of a diesel generator, power distribution cables, transformers, switch gear, motor controllers, power panel boards, lighting panel boards, lighting equipment, lightning protection equipment, control cabling, and grounding system. Emergency power is generated with a diesel generator located in a QL-2 structure and connected to the QL-2 bus. The Waste Handling Building Electrical System distributes and controls primary power to acceptable industry standards, and with a dependability compatible with waste handling building reliability objectives for non-safety electrical loads. It also generates and distributes emergency power to the designated emergency loads. The Waste Handling Building Electrical System receives power from the Site Electrical Power System. The primary material handling power interfaces include the Carrier/Cask Handling System, Canister Transfer System, Assembly Transfer System, Waste Package Remediation System, and Disposal Container Handling Systems. The system interfaces with the MGR Operations Monitoring and Control System for supervisory monitoring and control signals. The system interfaces with all facility support loads such as heating, ventilation, and air conditioning, office, fire protection, monitoring and control, safeguards and security, and communications subsystems.« less
Energy efficiency indicators for high electric-load buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aebischer, Bernard; Balmer, Markus A.; Kinney, Satkartar
2003-06-01
Energy per unit of floor area is not an adequate indicator for energy efficiency in high electric-load buildings. For two activities, restaurants and computer centres, alternative indicators for energy efficiency are discussed.
Statistical Analysis of Solar PV Power Frequency Spectrum for Optimal Employment of Building Loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olama, Mohammed M; Sharma, Isha; Kuruganti, Teja
In this paper, a statistical analysis of the frequency spectrum of solar photovoltaic (PV) power output is conducted. This analysis quantifies the frequency content that can be used for purposes such as developing optimal employment of building loads and distributed energy resources. One year of solar PV power output data was collected and analyzed using one-second resolution to find ideal bounds and levels for the different frequency components. The annual, seasonal, and monthly statistics of the PV frequency content are computed and illustrated in boxplot format. To examine the compatibility of building loads for PV consumption, a spectral analysis ofmore » building loads such as Heating, Ventilation and Air-Conditioning (HVAC) units and water heaters was performed. This defined the bandwidth over which these devices can operate. Results show that nearly all of the PV output (about 98%) is contained within frequencies lower than 1 mHz (equivalent to ~15 min), which is compatible for consumption with local building loads such as HVAC units and water heaters. Medium frequencies in the range of ~15 min to ~1 min are likely to be suitable for consumption by fan equipment of variable air volume HVAC systems that have time constants in the range of few seconds to few minutes. This study indicates that most of the PV generation can be consumed by building loads with the help of proper control strategies, thereby reducing impact on the grid and the size of storage systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-09-01
This brochure addresses gaps in actionable knowledge that can help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. This brochure should be used to make these decisions so systems can operate more energy efficiently; upfront capital costs will also decrease. This information can also be used to drive changes in negotiations about PPL energy demands. It should enable brokers and tenants to agree about lower PPL capacities. Owner-occupied buildings will also benefit.more » Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems.« less
NASA Astrophysics Data System (ADS)
Liang, Ya-Wei; Zhang, Hong-Mei; Dong, Jin-Zhi; Shi, Zhen-Hua
2016-05-01
Building Integrated Photovoltaic (BIPV) is a resort to save energy and reduce heat gain of buildings, utilize new and renewable energy, solve environment problems and alleviate electricity shortage in large cities. The area needed to generate power makes facade integrated photovoltaic panel a superb choice, especially in high-rise buildings. Numerous scholars have hitherto explored Building Facade Integrated Photovoltaic, however, focusing mainly on thermal performance, which fails to ensure seismic safety of high-rise buildings integrated photovoltaic. Based on connecting forms of the glass curtain wall, a connector jointing photovoltaic panel and facade was designed, which underwent loading position and size optimization. Static loading scenarios were conducted to test and verify the connector's mechanical properties under gravity and wind loading by means of HyperWorks. Compared to the unoptimized design, the optimized one saved material and managed to reduce maximum deflection by 74.64%.
Looking Northwest at First Floor Typical Wall and Ceiling Juncture ...
Looking Northwest at First Floor Typical Wall and Ceiling Juncture in Oxide Building and Loading Dock - Hematite Fuel Fabrication Facility, Oxide Building & Oxide Loading Dock, 3300 State Road P, Festus, Jefferson County, MO
Study of fuel cell on-site, integrated energy systems in residential/commercial applications
NASA Technical Reports Server (NTRS)
Wakefield, R. A.; Karamchetty, S.; Rand, R. H.; Ku, W. S.; Tekumalla, V.
1980-01-01
Three building applications were selected for a detailed study: a low rise apartment building; a retail store, and a hospital. Building design data were then specified for each application, based on the design and construction of typical, actual buildings. Finally, a computerized building loads analysis program was used to estimate hourly end use load profiles for each building. Conventional and fuel cell based energy systems were designed and simulated for each building in each location. Based on the results of a computer simulation of each energy system, levelized annual costs and annual energy consumptions were calculated for all systems.
Feasibility of solid oxide fuel cell dynamic hydrogen coproduction to meet building demand
NASA Astrophysics Data System (ADS)
Shaffer, Brendan; Brouwer, Jacob
2014-02-01
A dynamic internal reforming-solid oxide fuel cell system model is developed and used to simulate the coproduction of electricity and hydrogen while meeting the measured dynamic load of a typical southern California commercial building. The simulated direct internal reforming-solid oxide fuel cell (DIR-SOFC) system is controlled to become an electrical load following device that well follows the measured building load data (3-s resolution). The feasibility of the DIR-SOFC system to meet the dynamic building demand while co-producing hydrogen is demonstrated. The resulting thermal responses of the system to the electrical load dynamics as well as those dynamics associated with the filling of a hydrogen collection tank are investigated. The DIR-SOFC system model also allows for resolution of the fuel cell species and temperature distributions during these dynamics since thermal gradients are a concern for DIR-SOFC.
NREL's Work for the U.S. Navy Illuminates Energy and Cost Savings | News
load controls and whole-building energy efficiency retrofits as good investments for the Navy. " Program Director Steve Gorin said. Advanced power strips, a plug load control technology that cuts power and an office building with capacity for roughly 100 staff. While plug load savings depend on what can
Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahimpour, Alireza; Qi, Hairong; Fugate, David L
Heating, Ventilating and Air Conditioning units (HVAC) are a major electrical energy consumer in buildings. Monitoring of the operation and energy consumption of HVAC would increase the awareness of building owners and maintenance service providers of the condition and quality of performance of these units, enabling conditioned-based maintenance which would help achieving higher energy efficiency. In this paper, a novel non-intrusive load monitoring method based on group constrained non-negative matrix factorization is proposed for monitoring the different components of HVAC unit by only measuring the whole building aggregated power signal. At the first level of this hierarchical approach, power consumptionmore » of the building is decomposed to energy consumption of the HVAC unit and all the other electrical devices operating in the building such as lighting and plug loads. Then, the estimated power signal of the HVAC is used for estimating the power consumption profile of the HVAC major electrical loads such as compressors, condenser fans and indoor blower. Experiments conducted on real data collected from a building testbed maintained at the Oak Ridge National Laboratory (ORNL) demonstrate high accuracy on the disaggregation task.« less
Thermal dynamic simulation of wall for building energy efficiency under varied climate environment
NASA Astrophysics Data System (ADS)
Wang, Xuejin; Zhang, Yujin; Hong, Jing
2017-08-01
Aiming at different kind of walls in five cities of different zoning for thermal design, using thermal instantaneous response factors method, the author develops software to calculation air conditioning cooling load temperature, thermal response factors, and periodic response factors. On the basis of the data, the author gives the net work analysis about the influence of dynamic thermal of wall on air-conditioning load and thermal environment in building of different zoning for thermal design regional, and put forward the strategy how to design thermal insulation and heat preservation wall base on dynamic thermal characteristic of wall under different zoning for thermal design regional. And then provide the theory basis and the technical references for the further study on the heat preservation with the insulation are in the service of energy saving wall design. All-year thermal dynamic load simulating and energy consumption analysis for new energy-saving building is very important in building environment. This software will provide the referable scientific foundation for all-year new thermal dynamic load simulation, energy consumption analysis, building environment systems control, carrying through farther research on thermal particularity and general particularity evaluation for new energy -saving walls building. Based on which, we will not only expediently design system of building energy, but also analyze building energy consumption and carry through scientific energy management. The study will provide the referable scientific foundation for carrying through farther research on thermal particularity and general particularity evaluation for new energy saving walls building.
3. BUILDING 0503, NORTH FRONT AND WEST SIDE, WITH LOADING ...
3. BUILDING 0503, NORTH FRONT AND WEST SIDE, WITH LOADING DOCK AND GABLE ROOFED SHED. - Edwards Air Force Base, South Base Sled Track, Earth Covered Bunker Types, North of Sled Track, Lancaster, Los Angeles County, CA
NASA Astrophysics Data System (ADS)
Huang, Yin-Nan
Nuclear power plants (NPPs) and spent nuclear fuel (SNF) are required by code and regulations to be designed for a family of extreme events, including very rare earthquake shaking, loss of coolant accidents, and tornado-borne missile impacts. Blast loading due to malevolent attack became a design consideration for NPPs and SNF after the terrorist attacks of September 11, 2001. The studies presented in this dissertation assess the performance of sample conventional and base isolated NPP reactor buildings subjected to seismic effects and blast loadings. The response of the sample reactor building to tornado-borne missile impacts and internal events (e.g., loss of coolant accidents) will not change if the building is base isolated and so these hazards were not considered. The sample NPP reactor building studied in this dissertation is composed of containment and internal structures with a total weight of approximately 75,000 tons. Four configurations of the reactor building are studied, including one conventional fixed-base reactor building and three base-isolated reactor buildings using Friction Pendulum(TM), lead rubber and low damping rubber bearings. The seismic assessment of the sample reactor building is performed using a new procedure proposed in this dissertation that builds on the methodology presented in the draft ATC-58 Guidelines and the widely used Zion method, which uses fragility curves defined in terms of ground-motion parameters for NPP seismic probabilistic risk assessment. The new procedure improves the Zion method by using fragility curves that are defined in terms of structural response parameters since damage and failure of NPP components are more closely tied to structural response parameters than to ground motion parameters. Alternate ground motion scaling methods are studied to help establish an optimal procedure for scaling ground motions for the purpose of seismic performance assessment. The proposed performance assessment procedure is used to evaluate the vulnerability of the conventional and base-isolated NPP reactor buildings. The seismic performance assessment confirms the utility of seismic isolation at reducing spectral demands on secondary systems. Procedures to reduce the construction cost of secondary systems in isolated reactor buildings are presented. A blast assessment of the sample reactor building is performed for an assumed threat of 2000 kg of TNT explosive detonated on the surface with a closest distance to the reactor building of 10 m. The air and ground shock waves produced by the design threat are generated and used for performance assessment. The air blast loading to the sample reactor building is computed using a Computational Fluid Dynamics code Air3D and the ground shock time series is generated using an attenuation model for soil/rock response. Response-history analysis of the sample conventional and base isolated reactor buildings to external blast loadings is performed using the hydrocode LS-DYNA. The spectral demands on the secondary systems in the isolated reactor building due to air blast loading are greater than those for the conventional reactor building but much smaller than those spectral demands associated with Safe Shutdown Earthquake shaking. The isolators are extremely effective at filtering out high acceleration, high frequency ground shock loading.
Human Impact of Technological Innovation on the Battlefield
1985-03-15
C-2147 •~4. .. i" Va• LýCTE T.N. Dupuy Associates , Inc. (TNDA) •\\L T P.O. Box 157 JU 12 935 Dunn Loring, Virginia 22027 J 2 ___- Approved for public...ADORESS 10. PROGRAM ELEMENT. PROJECT, TASKA tEA I WORK UNiT NUMU RS T.N. Dupuy Associates , Inc. (TNDA) 62777A.3E162777A879.AA.009 P.O. Box 157 Dunn...proximity fuze, Beehive round, improved II. ASSTRACT (Cointlne an reverse side II necesaery aid Idenlify by block number) The study examines the
Job Aid Manuals for Phase I-ANALYZE of the Instructional systems Development Model
1980-05-01
with thuTb amd index Pinchinq nose shut finger. pre ents air leakage 7.2 Use hand to exert pressure on fore- head to maintain backward head tilt. 8...ALlMEE Prep tiol /o- Firi . (1) Turn the slot in the striker (at the nose of the frze) to Mine with the SQ index or the D index on the fuze body...12 Index and Description of Army Training Devices Good * Course materials: Correspondance course lessons and materials used in Good resident courses
1981-01-22
Arsenal Contract DUAA25-69-C- 0301 dated 3-10-69 for "Services to design and develop an automated line for assembly of Safety Adapter, Fuze, 1564...determine the line will function at the design rate of 5,000 acceptable assemblies per day and collect production data for incorporation into final...0,000 M564 Delay Arming Mechanisms of the line: Determine that the line will function at the design rate of 5,000. acceotabie asswml I es/day. Collect
Distributed Simulation Testing for Weapons System Performance of the F/A-18 and AIM-120 AMRAAM
1998-01-01
Support Facility (WSSF) at China Lake, CA and the AIM-120 Hardware in the Loop (HWIL) laboratory at Point Mugu, CA. The link was established in response to...ROCKET MOTOR TARGET DETECTION (FUZE) SEEKERIASSEMBLYWAH D . ANTENN ’ A TRA-kN.SiV, ITfrER’I" ACTUATOR ELECTRONICS DATA LIX -K PARAMETERS ADIMI20AI AIMI...test series. 3.2 Hardware in the Loop : The AMRAAM Hardware-In-the- Loop (HWIL) lab located at the Naval Air Warfare Center in Point Mugu, CA provides
Conceptual Design of a Basic Production Facility for the XM587E2/XM724 Electronic Time Fuzes
1977-11-01
blue side up, and then staked. The spri.ng pin is pressed in position and probed for the 1. 644-0. 010- inch dimension. See figure 33. 4.6.7.2 Parts...fitting subassembly. The detonator 69 IDLE HOPPER FEED -PROBE STAKE SPRING PIN PROBE PRESENCE STAKE LEADL IPROB LEADID ~ ASSEMBLY14 3 1 BLUE SIDE UP...automatic shutoffs. * Warning lights /alarms/ signs /’Jecals where necessary. * Electrical grounding of machine. [ 98 0 Noise levels below 85 decibals at
German Electrical Time and Impact Fuzes and Components
1945-09-24
6) The tube w ,s evacuated to 10 mn of mercury . -22- 11. Tubes Ueed in Slectrie^.l Time FVLZCB (Cont’d). (7) Tht leftds wore...discharge took place; the tune was then sealed off. The nrcssuro was usually 10 to 15 run of mercury . -23- t 0̂ — C - CAT/-/0£ <r z>/0£>£’ tjs...radioactive material (fine sulphide ) about 10 ram long and 1 mm wide was made on the outside of the, tube. (9) The tube wos dipped in a rTraphito
Stress-strain state of the structure in the service area of underground railway
NASA Astrophysics Data System (ADS)
Barabash, M.; Bashinsky, Y.; Korjakins, A.
2017-10-01
The paper focuses on numerical study how vibration due to underground trains influences the load-bearing building structures. Diagrams of vibration levels for monolithic floor slab depending on frequency are obtained. Levels of vibrations on floor slabs and columns are measured. The simulation of dynamic load from underground railway onto load-bearing building structures is presented as an example with account of load transmission through the soil. Recommendations for generation of design model in dynamic analysis of structure are provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghatikar, Girish; Cheung, Iris; Lanzisera, Steven
This report documents the technical evaluation of a collaborative research, development, and demonstration (RD&D) project that aims to address energy efficiency of Miscellaneous and Electronic Loads (MELs) (referred to as plug loads interchangeably in this report) using load monitoring and control devices. The goal s of this project are to identify and provide energy efficiency and building technologies to exemplary information technology (IT) office buildings, and to assist in transforming markets via technical assistance and engagement of Indian and U.S. stakeholders. This report describes the results of technology evaluation and United States – India collaboration between the Lawrence Berkeley Nationalmore » Laboratory (LBNL), Infosys Technologies Limited (India), and Smartenit, Inc. (U.S.) to address plug - load efficiency. The conclusions and recommendations focus on the larger benefits of such technologies and their impacts on both U.S. and Indian stakeholders.« less
Conceptual optimization using genetic algorithms for tube in tube structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pârv, Bianca Roxana; Hulea, Radu; Mojolic, Cristian
2015-03-10
The purpose of this article is to optimize the tube in tube structural systems for tall buildings under the horizontal wind loads. It is well-known that the horizontal wind loads is the main criteria when choosing the structural system, the types and the dimensions of structural elements in the majority of tall buildings. Thus, the structural response of tall buildings under the horizontal wind loads will be analyzed for 40 story buildings and a total height of 120 meters; the horizontal dimensions will be 30m × 30m for the first two optimization problems and 15m × 15m for the third.more » The optimization problems will have the following as objective function the cross section area, as restrictions the displacement of the building< the admissible displacement (H/500), and as variables the cross section dimensions of the structural elements.« less
33. Photocopied 1983 from original drawing (DP29179), Picatinny Arsenal, April ...
33. Photocopied 1983 from original drawing (DP-29179), Picatinny Arsenal, April 15, 1941. 'BUILDING NO. 454: BAG LOADING BUILDING, LIGHTNING PROTECTION--ELEVATION'. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
Inexpensive semi-autonomous ground vehicles for defusing IEDs
NASA Astrophysics Data System (ADS)
Davenport, Chris; Lodmell, James; Womble, Phillip C.; Barzilov, Alexander; Paschal, Jon; Hernandez, Robert; Moss, Kyle T.; Hopper, Lindsay
2008-04-01
Improvised explosive devices (IEDs) are an important concern to coalition forces during the conflicts in the Middle East. These devices are responsible for many casualties to American armed forces in the Middle East. These explosives are particularly dangerous because they are improvised with materials readily available to the designer, and there is no systematic way of explosive ordinance disposal. IEDs can be made from things such as standard military ammunition and can be detonated with common electronic devices such as cell phones and garage door openers. There is a great need for a low cost solution to neutralize these IEDs. At the Applied Physics Institute we are building a single function disrupter robot whose sole purpose is to neutralize these IEDs. We are modifying a toy remote control car to control it either wirelessly using WI-FI (IEEE 802.11) or wired by tethering the vehicle with an Ethernet cable (IEEE 802.3). The robot will be equipped with a high velocity fuze disrupter to neutralize the IED as well as a video camera for inspection and aiming purposes. This robot utilizes commercial-off-the-shelf (COTS) components which keeps the cost relatively low. Currently, similar robot systems have been deployed in Iraq and elsewhere but their method of operation is such that it is impractical to use in non-combat situations. We will discuss our design and possible deployment scenarios.
NECAP 4.1: NASA's Energy-Cost Analysis Program input manual
NASA Technical Reports Server (NTRS)
Jensen, R. N.
1982-01-01
The computer program NECAP (NASA's Energy Cost Analysis Program) is described. The program is a versatile building design and energy analysis tool which has embodied within it state of the art techniques for performing thermal load calculations and energy use predictions. With the program, comparisons of building designs and operational alternatives for new or existing buildings can be made. The major feature of the program is the response factor technique for calculating the heat transfer through the building surfaces which accounts for the building's mass. The program expands the response factor technique into a space response factor to account for internal building temperature swings; this is extremely important in determining true building loads and energy consumption when internal temperatures are allowed to swing.
Space Heating Load Estimation Procedure for CHP Systems sizing
NASA Astrophysics Data System (ADS)
Vocale, P.; Pagliarini, G.; Rainieri, S.
2015-11-01
Due to its environmental and energy benefits, the Combined Heat and Power (CHP) represents certainly an important measure to improve energy efficiency of buildings. Since the energy performance of the CHP systems strongly depends on the fraction of the useful cogenerated heat (i.e. the cogenerated heat that is actually used to meet building thermal demand), in building applications of CHP, it is necessary to know the space heating and cooling loads profile to optimise the system efficiency. When the heating load profile is unknown or difficult to calculate with a sufficient accuracy, as may occur for existing buildings, it can be estimated from the cumulated energy uses by adopting the loads estimation procedure (h-LEP). With the aim to evaluate the useful fraction of the cogenerated heat for different operating conditions in terms of buildings characteristics, weather data and system capacity, the h-LEP is here implemented with a single climate variable: the hourly average dry- bulb temperature. The proposed procedure have been validated resorting to the TRNSYS simulation tool. The results, obtained by considering a building for hospital use, reveal that the useful fraction of the cogenerated heat can be estimated with an average accuracy of ± 3%, within the range of operative conditions considered in the present study.
Energy efficiency evaluation of hospital building office
NASA Astrophysics Data System (ADS)
Fitriani, Indah; Sangadji, Senot; Kristiawan, S. A.
2017-01-01
One of the strategy employed in building design is reducing energy consumption while maintaining the best comfort zone in building indoor climate. The first step to improve office buildings energy performance by evaluating its existing energy usage using energy consumption intensity (Intensitas Konsumsi Energi, IKE) index. Energy evaluation of office building for hospital dr. Sayidiman at Kabupaten Magetan has been carried out in the initial investigation. The office building is operated with active cooling (air conditioning, AC) and use limited daylighting which consumes 14.61 kWh/m2/month. This IKE value is attributed into a slightly inefficient category. Further investigation was carried out by modeling and simulating thermal energy load and room lighting in every building zone using of Ecotect from Autodesk. Three scenarios of building energy and lighting retrofit have been performed simulating representing energy efficiency using cross ventilation, room openings, and passive cooling. The results of the numerical simulation indicate that the third scenario by employing additional windows, reflector media and skylight exhibit the best result and in accordance with SNI 03-6575-2001 lighting standard. Total thermal load of the existing building which includes fabric gains, indirect solar gains, direct solar gains, ventilation fans, internal gains, inter-zonal gains and cooling load were 162,145.40 kWh. Based on the three scenarios, the thermal load value (kWh) obtained was lowest achieved scenario 2 with the thermal value of 117,539.08 kWh.The final results are interpreted from the total energy emissions evaluated using the Ecotect software, the heating and cooling demand value and specific design of the windows are important factors to determine the energy efficiency of the buildings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hao, He; Liu, Guopeng; Huang, Sen
Renewable energy resources such as wind and solar power have a high degree of uncertainty. Large-scale integration of these variable generation sources into the grid is a big challenge for power system operators. Buildings, in which we live and work, consume about 75% of the total electricity in the United States. They also have a large capacity of power flexibility due to their massive thermal capacitance. Therefore, they present a great opportunity to help the grid to manage power balance. In this report, we study coordination and control of flexible building loads for renewable integration. We first present the motivationmore » and background, and conduct a literature review on building-to-grid integration. We also compile a catalog of flexible building loads that have great potential for renewable integration, and discuss their characteristics. We next collect solar generation data from a photovoltaic panel on Pacific Northwest National Laboratory campus, and conduct data analysis to study their characteristics. We find that solar generation output has a strong uncertainty, and the uncertainty occurs at almost all time scales. Additional data from other sources are also used to verify our study. We propose two transactive coordination strategies to manage flexible building loads for renewable integration. We prove the theories that support the two transactive coordination strategies and discuss their pros and cons. In this report, we select three types of flexible building loads—air-handling unit, rooftop unit, and a population of WHs—for which we demonstrate control of the flexible load to track a dispatch signal (e.g., renewable generation fluctuation) using experiment, simulation, or hardware-in-the-loop study. More specifically, we present the system description, model identification, controller design, test bed setup, and experiment results for each demonstration. We show that coordination and control of flexible loads has a great potential to integrate variable generation sources. The flexible loads can successfully track a power dispatch signal from the coordinator, while having little impact on the quality of service to the end-users.« less
Introduction to Building Systems Performance: Houses That Work II. Revised February 2005
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2005-03-01
Buildings should be suited to their environments. Design and construction must be responsive to varying seismic risks, wind loads, and snow loads, as well as soil conditions, frost depth, orientation, and solar radiation. In addition, building envelopes and mechanical systems should be designed for a specific hygro-thermal regions, rain exposure, and interior climate. The Building Science Consortium (BSC) design recommendations are based on the hygro-thermal regions with reference to the annual rainfall. Local climate must be addressed if it differs significantly from the climate described for a particular design.
2001-04-01
construction, numerous non load- bearing walls, and large windows. Commercial offices and high rise buildings are generally framed with steel girders...Mass buildings are built so exterior walls bear the weight of the structure. The walls of mass structures are usually thick and constructed of...buildings are similar in size to Type 5 office buildings, but with less glass and with load- bearing reinforced concrete walls. They offer greater protection
Experimental study on lateral strength of wall-slab joint subjected to lateral cyclic load
NASA Astrophysics Data System (ADS)
Masrom, Mohd Asha'ari; Mohamad, Mohd Elfie; Hamid, Nor Hayati Abdul; Yusuff, Amer
2017-10-01
Tunnel form building has been utilised in building construction since 1960 in Malaysia. This method of construction has been applied extensively in the construction of high rise residential house (multistory building) such as condominium and apartment. Most of the tunnel form buildings have been designed according to British standard (BS) whereby there is no provision for seismic loading. The high-rise tunnel form buildings are vulnerable to seismic loading. The connections between slab and shear walls in the tunnel-form building constitute an essential link in the lateral load resisting mechanism. Malaysia is undergoing a shifting process from BS code to Eurocode (EC) for building construction since the country has realised the safety threats of earthquake. Hence, this study is intended to compare the performance of the interior wall slab joint for a tunnel form structure designed based on Euro and British codes. The experiment included a full scale test of the wall slab joint sub-assemblages under reversible lateral cyclic loading. Two sub-assemblage specimens of the wall slab joint were designed and constructed based on both codes. Each specimen was tested using lateral displacement control (drift control). The specimen designed by using Eurocode was found could survive up to 3.0% drift while BS specimen could last to 1.5% drift. The analysis results indicated that the BS specimen was governed by brittle failure modes with Ductility Class Low (DCL) while the EC specimen behaved in a ductile manner with Ductility Class Medium (DCM). The low ductility recorded in BS specimen was resulted from insufficient reinforcement provided in the BS code specimen. Consequently, the BS specimen could not absorb energy efficiently (low energy dissipation) and further sustain under inelastic deformation.
Electric load shape benchmarking for small- and medium-sized commercial buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Xuan; Hong, Tianzhen; Chen, Yixing
Small- and medium-sized commercial buildings owners and utility managers often look for opportunities for energy cost savings through energy efficiency and energy waste minimization. However, they currently lack easy access to low-cost tools that help interpret the massive amount of data needed to improve understanding of their energy use behaviors. Benchmarking is one of the techniques used in energy audits to identify which buildings are priorities for an energy analysis. Traditional energy performance indicators, such as the energy use intensity (annual energy per unit of floor area), consider only the total annual energy consumption, lacking consideration of the fluctuation ofmore » energy use behavior over time, which reveals the time of use information and represents distinct energy use behaviors during different time spans. To fill the gap, this study developed a general statistical method using 24-hour electric load shape benchmarking to compare a building or business/tenant space against peers. Specifically, the study developed new forms of benchmarking metrics and data analysis methods to infer the energy performance of a building based on its load shape. We first performed a data experiment with collected smart meter data using over 2,000 small- and medium-sized businesses in California. We then conducted a cluster analysis of the source data, and determined and interpreted the load shape features and parameters with peer group analysis. Finally, we implemented the load shape benchmarking feature in an open-access web-based toolkit (the Commercial Building Energy Saver) to provide straightforward and practical recommendations to users. The analysis techniques were generic and flexible for future datasets of other building types and in other utility territories.« less
Electric load shape benchmarking for small- and medium-sized commercial buildings
Luo, Xuan; Hong, Tianzhen; Chen, Yixing; ...
2017-07-28
Small- and medium-sized commercial buildings owners and utility managers often look for opportunities for energy cost savings through energy efficiency and energy waste minimization. However, they currently lack easy access to low-cost tools that help interpret the massive amount of data needed to improve understanding of their energy use behaviors. Benchmarking is one of the techniques used in energy audits to identify which buildings are priorities for an energy analysis. Traditional energy performance indicators, such as the energy use intensity (annual energy per unit of floor area), consider only the total annual energy consumption, lacking consideration of the fluctuation ofmore » energy use behavior over time, which reveals the time of use information and represents distinct energy use behaviors during different time spans. To fill the gap, this study developed a general statistical method using 24-hour electric load shape benchmarking to compare a building or business/tenant space against peers. Specifically, the study developed new forms of benchmarking metrics and data analysis methods to infer the energy performance of a building based on its load shape. We first performed a data experiment with collected smart meter data using over 2,000 small- and medium-sized businesses in California. We then conducted a cluster analysis of the source data, and determined and interpreted the load shape features and parameters with peer group analysis. Finally, we implemented the load shape benchmarking feature in an open-access web-based toolkit (the Commercial Building Energy Saver) to provide straightforward and practical recommendations to users. The analysis techniques were generic and flexible for future datasets of other building types and in other utility territories.« less
45. Building 102, view of waveguide "coaxial waste load" device ...
45. Building 102, view of waveguide "coaxial waste load" device connected to waveguide combiner. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
19. Photocopied 1983, from original drawing (CP12501), Picatinny Arsenal, September ...
19. Photocopied 1983, from original drawing (CP-12501), Picatinny Arsenal, September 25, 1929. BUILDING NO. 448, 'BAG LOADING AREA SAFETY CHUTE--BUILDING T-868 448'. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
NASA Astrophysics Data System (ADS)
Afifuddin, M.; Panjaitan, M. A. R.; Ayuna, D.
2017-02-01
Earthquakes are one of the most dangerous, destructive and unpredictable natural hazards, which can leave everything up to a few hundred kilometres in complete destruction in seconds. Indonesia has a unique position as an earthquake prone country. It is the place of the interaction for three tectonic plates, namely the Indo-Australian, Eurasian and Pacific plates. Banda Aceh is one of the cities that located in earthquake-prone areas. Due to the vulnerable conditions of Banda Aceh some efforts have been exerted to reduce these unfavourable conditions. Many aspects have been addressed, starting from community awareness up to engineering solutions. One of them is all buildings that build in the city should be designed as an earthquake resistant building. The objectives of this research are to observe the response of a reinforced concrete structure due to several types of earthquake load, and to see the performance of the structure after earthquake loads applied. After Tsunami in 2004 many building has been build, one of them is a hotel building located at simpang lima. The hotel is made of reinforced concrete with a height of 34.95 meters with a total area of 8872.5 m2 building. So far this building was the tallest building in Banda Aceh.
NASA Astrophysics Data System (ADS)
Kadela, Marta; Chomacki, Leszek
2017-10-01
The soil’s load on retention walls or underground elements of engineering structures consists of three basic types of pressure: active pressure (p a ), passive pressure (p b ) and at-rest pressure (p 0 ). In undisturbed areas without any mining, due to lack of activity in the soil, specific forces from the soil are stable and unchanging throughout the structure’s life. Mining activity performed at a certain depth activates the soil. Displacements take place in the surface layer of the rock mass, which begins to act on the structure embedded in it, significantly changing the original stress distribution. Deformation of the subgrade, mainly horizontal strains, becomes a source of significant additional actions in the contact zone between the structure and the soil, constituting an additional load for the structure. In order to monitor the mining influence in the form of compressive load on building walls, an observation line was set up in front of two buildings located in Silesia (in Mysłowice). In 2013, some mining activity took place directly under those buildings, with expected horizontal strains of εx = -5.8 mm/m. The measurement results discussed in this paper showed that, as predicted, the buildings were subjected only to horizontal compressive strains with the values parallel to the analysed wall being less than -4.0 ‰ for first building and -1.5‰ for second building, and values perpendicular to the analysed wall being less than -6.0‰ for first building and -4.0‰ for second building (the only exception was the measurement in line 8-13, where εx = -17.04‰ for first building and -4.57‰ for second building). The horizontal displacement indicate that the impact of mining activity was greater on first building. This is also confirmed by inspections of the damage.
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE... Proposed Design or for calculation of Design Energy Cost. 512.2Internal loads for multi-family high-rise residential buildings are prescribed in Tables 512.2.a and b, Multi-Family High Rise Residential Building...
Comparison of Building Energy Modeling Programs: Building Loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Dandan; Hong, Tianzhen; Yan, Da
This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In themore » fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to identify the differences in solution algorithms, modeling assumptions and simplifications. Identifying inputs of each program and their default values or algorithms for load simulation was a critical step. These tend to be overlooked by users, but can lead to large discrepancies in simulation results. As weather data was an important input, weather file formats and weather variables used by each program were summarized. Some common mistakes in the weather data conversion process were discussed. ASHRAE Standard 140-2007 tests were carried out to test the fundamental modeling capabilities of the load calculations of the three BEMPs, where inputs for each test case were strictly defined and specified. The tests indicated that the cooling and heating load results of the three BEMPs fell mostly within the range of spread of results from other programs. Based on ASHRAE 140-2007 test results, the finer differences between DeST and EnergyPlus were further analyzed by designing and conducting additional tests. Potential key influencing factors (such as internal gains, air infiltration, convection coefficients of windows and opaque surfaces) were added one at a time to a simple base case with an analytical solution, to compare their relative impacts on load calculation results. Finally, special tests were designed and conducted aiming to ascertain the potential limitations of each program to perform accurate load calculations. The heat balance module was tested for both single and double zone cases. Furthermore, cooling and heating load calculations were compared between the three programs by varying the heat transfer between adjacent zones, the occupancy of the building, and the air-conditioning schedule.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schetrit, Oren; Kim, Joyce; Yin, Rongxin
2014-08-01
Automated demand response (Auto-DR) is expected to close the loop between buildings and the grid by providing machine-to-machine communications to curtail loads without the need for human intervention. Hence, it can offer more reliable and repeatable demand response results to the grid than the manual approach and make demand response participation a hassle-free experience for customers. However, many building operators misunderstand Auto-DR and are afraid of losing control over their building operation. To ease the transition from manual to Auto-DR, we designed and implemented granular control of Auto-DR systems so that building operators could modify or opt out of individualmore » load-shed strategies whenever they wanted. This paper reports the research findings from this effort demonstrated through a field study in large commercial buildings located in New York City. We focused on (1) understanding how providing granular control affects building operators’ perspective on Auto-DR, and (2) evaluating the usefulness of granular control by examining their interaction with the Auto-DR user interface during test events. Through trend log analysis, interviews, and surveys, we found that: (1) the opt-out capability during Auto-DR events can remove the feeling of being forced into load curtailments and increase their willingness to adopt Auto-DR; (2) being able to modify individual load-shed strategies allows flexible Auto-DR participation that meets the building’s changing operational requirements; (3) a clear display of automation strategies helps building operators easily identify how Auto-DR is functioning and can build trust in Auto-DR systems.« less
Monitoring and Characterization of Miscellaneous Electrical Loads in a Large Retail Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gentile-Polese, L.; Frank, S.; Sheppy, M.
2014-02-01
Buildings account for 40% of primary energy consumption in the United States (residential 22%; commercial 18%). Most (70% residential and 79% commercial) is used as electricity. Thus, almost 30% of U.S. primary energy is used to provide electricity to buildings. Plug loads play an increasingly critical role in reducing energy use in new buildings (because of their increased efficiency requirements), and in existing buildings (as a significant energy savings opportunity). If all installed commercial building miscellaneous electrical loads (CMELs) were replaced with energy-efficient equipment, a potential annual energy saving of 175 TWh, or 35% of the 504 TWh annual energymore » use devoted to MELs, could be achieved. This energy saving is equivalent to the annual energy production of 14 average-sized nuclear power plants. To meet DOE's long-term goals of reducing commercial building energy use and carbon emissions, the energy efficiency community must better understand the components and drivers of CMEL energy use, and develop effective reduction strategies. These goals can be facilitated through improved data collection and monitoring methodologies, and evaluation of CMELs energy-saving techniques.« less
A case study on the structural assessment of fire damaged building
NASA Astrophysics Data System (ADS)
Osman, M. H.; Sarbini, N. N.; Ibrahim, I. S.; Ma, C. K.; Ismail, M.; Mohd, M. F.
2017-11-01
This paper presents a case study on the structural assessment of building damaged by fire and discussed on the site investigations and test results prior to determine the existing condition of the building. The building was on fire for about one hour before it was extinguished. In order to ascertain the integrity of the building, a visual inspection was conducted for all elements (truss, beam, column and wall), followed by non-destructive, load and material tests. The load test was conducted to determine the ability of truss to resist service load, while the material test to determine the residual strength of the material. At the end of the investigation, a structural analysis was carried out to determine the new factor of safety by considering the residual strength. The highlighted was on the truss element due to steel behaviour that is hardly been predicted. Meanwhile, reinforced concrete elements (beam, column and wall) were found externally affected and caused its strength to be considered as sufficient for further used of building. The new factor of safety is equal to 2, considered as the minimum calculated value for the truss member. Therefore, this fire damaged building was found safe and can be used for further application.
Low-Load Space Conditioning Needs Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puttagunta, Srikanth
Heating, ventilating, and air-conditioning (HVAC) equipment must be right-sized to ensure energy performance and comfort. With limited low-load options in the HVAC market, many new-construction housing units are being fitted with oversized equipment that creates system efficiency, comfort, and cost penalties. To bridge the gap between currently available HVAC equipment that is oversized or inefficient and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of the needs of the multifamily building and attached single-family (duplex and townhouse) home market. Over the past decade, Steven Winter Associates, Inc. (SWA) has providedmore » certification and consulting services for hundreds of housing projects and has accrued a large pool of data that describe multifamily and attached single-family home characteristics. The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) compiled and analyzed these data to outline the characteristics of low-load dwellings such as the heating and cooling design loads.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yixing; Hong, Tianzhen
We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.« less
Chen, Yixing; Hong, Tianzhen
2018-02-20
We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.« less
Microelectromechanical safing and arming apparatus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koehler, David R; Hoke, Darren A; Weichman, Louis S
2006-05-30
A two-stage acceleration sensing apparatus is disclosed which has applications for use in a fuze assembly for a projected munition. The apparatus, which can be formed by bulk micromachining or LIGA, can sense acceleration components along two orthogonal directions to enable movement of a shuttle from an "as-fabricated" position to a final position and locking of the shuttle in the final position. With the shuttle moved to the final position, the apparatus can perform one or more functions including completing an explosive train or an electrical switch closure, or allowing a light beam to be transmitted through the device.
Microelectromechanical safing and arming apparatus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koehler, David R; Hoke, Darren A; Weichman, Louis S
2008-06-10
A two-stage acceleration sensing apparatus is disclosed which has applications for use in a fuze assembly for a projected munition. The apparatus, which can be formed by bulk micromachining or LIGA, can sense acceleration components along two orthogonal directions to enable movement of a shuttle from an "as-fabricated" position to a final position and locking of the shuttle in the final position. With the shuttle moved to the final position, the apparatus can perform one or more functions including completing an explosive train or an electrical switch closure, or allowing a light beam to be transmitted through the device.
Method of energy load management using PCM for heating and cooling of buildings
Stovall, T.K.; Tomlinson, J.J.
1996-03-26
A method is described for energy load management for the heating and cooling of a building. The method involves utilizing a wallboard as a portion of the building, the wallboard containing about 5 to about 30 wt.% phase change material such that melting of the phase change material occurs during a rise in temperature within the building to remove heat from the air, and a solidification of the phase change material occurs during a lowering of the temperature to dispense heat into the air. At the beginning of either of these cooling or heating cycles, the phase change material is preferably ``fully charged``. In preferred installations one type of wallboard is used on the interior surfaces of exterior walls, and another type as the surface on interior walls. The particular PCM is chosen for the desired wall and room temperature of these locations. In addition, load management is achieved by using PCM-containing wallboards that form cavities of the building such that the cavities can be used for the air handling duct and plenum system of the building. Enhanced load management is achieved by using a thermostat with reduced dead band of about the upper half of a normal dead band of over three degrees. In some applications, air circulation at a rate greater than normal convection provides additional comfort. 7 figs.
Structural pounding of concrete frame structure with masonry infill wall under seismic loading
NASA Astrophysics Data System (ADS)
Ismail, Rozaina; Hasnan, Mohd Hafizudin; Shamsudin, Nurhanis
2017-10-01
Structural pounding is additional problem than the other harmful damage that may occurs due to the earthquake vibrations. A lot of study has been made by past researcher but most of them did not include the walls. The infill masonry walls are rarely involved analysis of structural systems but it does contribute to earthquake response of the structures. In this research, a comparison between adjacent building of 10-storey and 7-storey concrete frame structure without of masonry infill walls and the same dynamic properties of buildings. The diagonal strut approach is adopted for modeling masonry infill walls. This research also focused on finding critical building separation in order to prevent the adjacent structures from pounding. LUSAS FEA v14.03 software has been used for modeling analyzing the behavior of structures due to seismic loading and the displacement each floor of the building has been taken in order to determine the critical separation distance between the buildings. From the analysis that has been done, it is found that masonry infill walls do affect the structures behavior under seismic load. Structures without masonry infill walls needs more distance between the structures to prevent structural pounding due to higher displacement of the buildings when it sways under seismic load compared to structures with masonry infill walls. This shows that contribution of masonry infill walls to the analysis of structures cannot be neglected.
Observations of Building Performance under Combined Wind and Surge Loading from Hurricane Harvey
NASA Astrophysics Data System (ADS)
Lombardo, F.; Roueche, D. B.; Krupar, R. J.; Smith, D. J.; Soto, M. G.
2017-12-01
Hurricane Harvey struck the Texas coastline on August 25, 2017, as a Category 4 hurricane - the first major hurricane to reach the US in twelve years. Wind gusts over 130 mph and storm surge as high as 12.5 ft caused widespread damage to buildings and critical infrastructure in coastal communities including Rockport, Fulton, Port Aransas and Aransas Pass. This study presents the methodology and preliminary observations of a coordinated response effort to document residential building performance under wind and storm surge loading. Over a twelve day survey period the study team assessed the performance of more than 1,000 individual, geo-located residential buildings. Assessments were logged via a smartphone application to facilitate rapid collection and collation of geotagged photographs, building attributes and structural details, and structural damage observations. Detailed assessments were also made of hazard intensity, specifically storm surge heights and both wind speed and direction indicators. Preliminary observations and findings will be presented, showing strong gradients in damage between inland and coastal regions of the affected areas that may be due in part to enhanced individual loading effects of wind and storm surge and potentially joint-hazard loading effects. Contributing factors to the many cases of disproportionate damage observed in close proximity will also be discussed. Ongoing efforts to relate building damage to near-surface hazard measurements (e.g., radar, anemometry) in close proximity will also be described.
Improving Thermal Performance of a Residential Building, Related to Its Orientations - A Case Study
NASA Astrophysics Data System (ADS)
Akshaya, S.; Harish, S.; Arthy, R.; Muthu, D.; Venkatasubramanian, C.
2017-07-01
Urban planners and stakeholders require knowledge about the effectiveness of city-scale climate adaptation measures in order to develop climate resilient cities and to push forward the political process for the implementation of climate adaptation strategies. This study examines the impact of modifications in orientation of buildings with respect to heat load. Heat load calculation is a mathematical process to determine the best capacity, application and style of HVAC system. The purpose is to ensure energy efficiency while also maximizing comfort inside the building. This study of load calculation is essential for a building because it helps to pick the best orientation and focuses to find an orientation that will reduce energy due to direct solar radiation. One of the factors affecting this assessment is the latitude of the location. The heat gain is effective through walls and fenestration. Improper management through ineffective orientation of the building’s natural heat gain leads to excessive consumption of energy in the form of CL. The total heat gain for the above factors is calculated with the equations and assumptions as per ASHRAE code. After the calculation of heat load for different orientations, the best suited orientation of the building is found. By altering the building to suitable orientation, the dependence on electrical equipment can be minimized and thereby helps in energy conservation.
Method of energy load management using PCM for heating and cooling of buildings
Stovall, Therese K.; Tomlinson, John J.
1996-01-01
A method of energy load management for the heating and cooling of a building. The method involves utilizing a wallboard as a portion of the building, the wallboard containing about 5 to about 30 wt. % a phase change material such that melting of the phase change material occurs during a rise in temperature within the building to remove heat from the air, and a solidification of the phase change material occurs during a lowering of the temperature to dispense heat into the air. At the beginning of either of these cooling or heating cycles, the phase change material is preferably "fully charged". In preferred installations one type of wallboard is used on the interior surfaces of exterior walls, and another type as the surface on interior walls. The particular PCM is chosen for the desired wall and room temperature of these locations. In addition, load management is achieved by using PCM-containing wallboard that form cavities of the building such that the cavities can be used for the air handling duct and plenum system of the building. Enhanced load management is achieved by using a thermostat with reduced dead band of about the upper half of a normal dead band of over three degree. In some applications, air circulation at a rate greater than normal convection provides additional comfort.
Method of energy load management using PCM for heating and cooling of buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stovall, T.K.; Tomlinson, J.J.
1996-03-26
A method is described for energy load management for the heating and cooling of a building. The method involves utilizing a wallboard as a portion of the building, the wallboard containing about 5 to about 30 wt.% phase change material such that melting of the phase change material occurs during a rise in temperature within the building to remove heat from the air, and a solidification of the phase change material occurs during a lowering of the temperature to dispense heat into the air. At the beginning of either of these cooling or heating cycles, the phase change material ismore » preferably ``fully charged``. In preferred installations one type of wallboard is used on the interior surfaces of exterior walls, and another type as the surface on interior walls. The particular PCM is chosen for the desired wall and room temperature of these locations. In addition, load management is achieved by using PCM-containing wallboards that form cavities of the building such that the cavities can be used for the air handling duct and plenum system of the building. Enhanced load management is achieved by using a thermostat with reduced dead band of about the upper half of a normal dead band of over three degrees. In some applications, air circulation at a rate greater than normal convection provides additional comfort. 7 figs.« less
Assessment and Rehabilitation Issues Concerning Existing 70’s Structural Stock
NASA Astrophysics Data System (ADS)
Sabareanu, E.
2017-06-01
The last 30 years were very demanding in terms of norms and standards change concerning the structural calculus for buildings, leaving a large stock of structures erected during 70-90 decades in a weak position concerning seismic loads and loads level for live loads, wind and snow. In the same time, taking into account that a large amount of buildings are in service all over the country, they cannot be demolished, but suitable rehabilitation methods should be proposed, structural durability being achieved. The paper proposes some rehabilitation methods suitable in terms of structural safety and cost optimization for diaphragm reinforced concrete structures, with an example on an existing multi storey building.
Control of Smart Building Using Advanced SCADA
NASA Astrophysics Data System (ADS)
Samuel, Vivin Thomas
For complete control of the building, a proper SCADA implementation and the optimization strategy has to be build. For better communication and efficiency a proper channel between the Communication protocol and SCADA has to be designed. This paper concentrate mainly between the communication protocol, and the SCADA implementation, for a better optimization and energy savings is derived to large scale industrial buildings. The communication channel used in order to completely control the building remotely from a distant place. For an efficient result we consider the temperature values and the power ratings of the equipment so that while controlling the equipment, we are setting a threshold values for FDD technique implementation. Building management system became a vital source for any building to maintain it and for safety purpose. Smart buildings, refers to various distinct features, where the complete automation system, office building controls, data center controls. ELC's are used to communicate the load values of the building to the remote server from a far location with the help of an Ethernet communication channel. Based on the demand fluctuation and the peak voltage, the loads operate differently increasing the consumption rate thus results in the increase in the annual consumption bill. In modern days, saving energy and reducing the consumption bill is most essential for any building for a better and long operation. The equipment - monitored regularly and optimization strategy is implemented for cost reduction automation system. Thus results in the reduction of annual cost reduction and load lifetime increase.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2004-04-01
Buildings should be suited to their environments. Design and construction must be responsive to varying seismic risks, wind loads, and snow loads, as well as soil conditions, frost depth, orientation, and solar radiation. In addition, building envelopes and mechanical systems should be designed for a specific hygro-thermal regions, rain exposure, and interior climate. The Building Science Consortium (BSC) design recommendations are based on the hygro-thermal regions with reference to the annual rainfall. Local climate must be addressed if it differs significantly from the climate described for a particular design.
Code of Federal Regulations, 2010 CFR
2010-01-01
... systems, building load simulation models, statistical regression analysis, or some combination of these..., excluding any cogeneration process for other than a federally owned building or buildings or other federally...
Interior moisture design loads for residences
Anton TenWolde; Iain S. Walker
2001-01-01
This paper outlines a methodology to obtain design values for indoor boundary conditions for moisture design calculations for residences. This is part of a larger effort by ASHRAE Standard Project Committee 160P, Design Criteria for Moisture Control in Buildings, to formulate criteria for moisture design loads, analysis techniques, and material and building performance...
The project is an integrative educational and research project that will revolutionize design and construction methods towards more sustainable buildings. The project will develop and test new product design concepts using bio-composite materials in load-bearing and fa&cced...
Development of Interlocking Masonry Bricks and its’ Structural Behaviour: A Review Paper
NASA Astrophysics Data System (ADS)
Al-Fakih, Amin; Mohammed, Bashar S.; Nuruddin, Fadhil; Nikbakht, Ehsan
2018-04-01
Conventional bricks are the most elementary building materials for houses construction. However, the rapid growth in today’s construction industry has obliged the civil engineers in searching for a new building technique that may result in even greater economy, more efficient and durable as an alternative for the conventional brick. Moreover, the high demands for having a speedy and less labour and cost building systems is one of the factor that cause the changes of the masonry conventional systems. These changes have led to improved constructability, performance, and cost as well. Several interlocking bricks has been developed and implemented in building constructions and a number of researches had studied the manufacturing of interlocking brick and its structural behaviour as load bearing and non-load bearing element. This technical paper aims to review the development of interlocking brick and its structural behaviour. In conclusion, the concept of interlocking system has been widely used as a replacement of the conventional system where it has been utilized either as load bearing or non-load bearing masonry system.
Optimal Scheduling Method of Controllable Loads in DC Smart Apartment Building
NASA Astrophysics Data System (ADS)
Shimoji, Tsubasa; Tahara, Hayato; Matayoshi, Hidehito; Yona, Atsushi; Senjyu, Tomonobu
2015-12-01
From the perspective of global warming suppression and the depletion of energy resources, renewable energies, such as the solar collector (SC) and photovoltaic generation (PV), have been gaining attention in worldwide. Houses or buildings with PV and heat pumps (HPs) are recently being used in residential areas widely due to the time of use (TOU) electricity pricing scheme which is essentially inexpensive during middle-night and expensive during day-time. If fixed batteries and electric vehicles (EVs) can be introduced in the premises, the electricity cost would be even more reduced. While, if the occupants arbitrarily use these controllable loads respectively, power demand in residential buildings may fluctuate in the future. Thus, an optimal operation of controllable loads such as HPs, batteries and EV should be scheduled in the buildings in order to prevent power flow from fluctuating rapidly. This paper proposes an optimal scheduling method of controllable loads, and the purpose is not only the minimization of electricity cost for the consumers, but also suppression of fluctuation of power flow on the power supply side. Furthermore, a novel electricity pricing scheme is also suggested in this paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rice, C. Keith; Shen, Bo; Shrestha, Som S.
This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirementmore » (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28% increase in delivered heating load and an ~52% increase in the estimated heating operating cost over that given in the AHRI directory (AHRI 2014).« less
Chen, Bei-Bei; Gong, Hui-Li; Li, Xiao-Juan; Lei, Kun-Chao; Lin, Zhu; Wang, Yan-Bing
2013-08-01
The excessive mining for underground water is the main reason inducing the land subsidence in Beijing, while, increasing of load brought by the urban construction aggravate the local land subsidence in a certain degree. As an international metropolis, the problems of land subsidence that caused by urban construction are becoming increasingly highlights, so revealing the relationship between regional load increase and the response of land subsidence also becomes one of the key problems in the land subsidence research field. In order to analyze the relationship between the load changes in construction and the land subsidence quantitatively, the present study selected the TM remote sensing image covering Beijing plain and used Erdas Modeler tool to invert the index based on building site (IBI), acquired the spatial and temporal change information in research area further; Based on results monitored by PS-InSAR (permanent scatterer interferometry) and IBI index method, and combined with the GIS spatial analysis method in the view of pixels in different scales, this paper analyzes the correlation between typical area load change and land subsidence, The conclusions show that there is a positive correlation between the density of load and the homogeneity of subsidence, especially in area which has a high sedimentation rate. Owing to such characteristics as the complexity and hysteretic nature of soil and geological structure, it is not obvious that the land subsidence caused by the increase of load in a short period. But with the increasing of local land load made by high density buildings and additional settlement of each monomer building superposed with each other, regional land subsidence is still a question that cannot be ignored and needs long-term systematic research and discussion.
Plug and Process Loads Capacity and Power Requirements Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheppy, M.; Gentile-Polese, L.
2014-09-01
This report addresses gaps in actionable knowledge that would help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. Limited initial data, however, suggest that actual PPL densities in leased buildings are substantially lower. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems. Better guidance will enable improved sizing and design of these systems, decrease upfront capital costs, and allow systems to operate more energy efficiently. The main focus ofmore » this report is to provide industry with reliable, objective third-party guidance to address the information gap in typical PPL densities for commercial building tenants. This could drive changes in negotiations about PPL energy demands.« less
Design automation of load-bearing arched structures of roofs of tall buildings
NASA Astrophysics Data System (ADS)
Kulikov, Vladimir
2018-03-01
The article considers aspects of the possible use of arched roofs in the construction of skyscrapers. Tall buildings experience large load from various environmental factors. Skyscrapers are subject to various and complex types of deformation of its structural elements. The paper discusses issues related to the aerodynamics of various structural elements of tall buildings. The technique of solving systems of equations state method of Simpson. The article describes the optimization of geometric parameters of bearing elements of the arched roofs of skyscrapers.
View northnorthwest of turret shed (building 56), at right of ...
View north-northwest of turret shed (building 56), at right of photograph. Electrical and electronics facility (building 1000) located south of drydock no. 2. The gantry crane and its supporting structure (left foreground) was used to load assembled gun turrets onto barges moored in the barge basin under the gantry structure. After loading on a crane on pier 4 and lifted into positioned on a battleship or cruiser. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Drydock No. 2, League Island, Philadelphia, Philadelphia County, PA
Seismic Performance Evaluation of Reinforced Concrete Frames Subjected to Seismic Loads
NASA Astrophysics Data System (ADS)
Zameeruddin, Mohd.; Sangle, Keshav K.
2017-06-01
Ten storied-3 bays reinforced concrete bare frame designed for gravity loads following the guidelines of IS 456 and IS 13920 for ductility is subjected to seismic loads. The seismic demands on this building were calculated by following IS 1893 for response spectra of 5% damping (for hard soil type). Plastic hinges were assigned to the beam and column at both ends to represent the failure mode, when member yields. Non-linear static (pushover) analysis was performed to evaluate the performance of the building in reference to first (ATC 40), second (FEMA 356) and next-generation (FEMA 440) performance based seismic design procedures. Base shear against top displacement curve of structure, known as pushover curve was obtained for two actions of plastic hinge behavior, force-controlled (brittle) and deformation-controlled (ductile) actions. Lateral deformation corresponding to performance point proves the building capability to sustain a certain level of seismic loads. The failure is represented by a sequence of formation of plastic hinges. Deformation-controlled action of hinges showed that building behaves like strong-column-weak-beam mechanism, whereas force-controlled action showed formation of hinges in the column. The study aims to understand the first, second and next generation performance based design procedure in prediction of actual building responses and their conservatism into the acceptance criteria.
23. BUILDING NO. 452, ORDNANCE FACILITY (BAG CHARGE FILLING PLANT), ...
23. BUILDING NO. 452, ORDNANCE FACILITY (BAG CHARGE FILLING PLANT), INTERIOR, LOOKING SOUTH DOWN CENTRAL CORRIDOR. NOTE BINS IN WALLS ON EITHER SIDE OF CORRIDOR, USED FOR PASSING EXPLOSIVES AND LOADED ITEMS TO SIEVING ROOMS BEYOND WALLS. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
Target-classification approach applied to active UXO sites
NASA Astrophysics Data System (ADS)
Shubitidze, F.; Fernández, J. P.; Shamatava, Irma; Barrowes, B. E.; O'Neill, K.
2013-06-01
This study is designed to illustrate the discrimination performance at two UXO active sites (Oklahoma's Fort Sill and the Massachusetts Military Reservation) of a set of advanced electromagnetic induction (EMI) inversion/discrimination models which include the orthonormalized volume magnetic source (ONVMS), joint diagonalization (JD), and differential evolution (DE) approaches and whose power and flexibility greatly exceed those of the simple dipole model. The Fort Sill site is highly contaminated by a mix of the following types of munitions: 37-mm target practice tracers, 60-mm illumination mortars, 75-mm and 4.5'' projectiles, 3.5'', 2.36'', and LAAW rockets, antitank mine fuzes with and without hex nuts, practice MK2 and M67 grenades, 2.5'' ballistic windshields, M2A1-mines with/without bases, M19-14 time fuzes, and 40-mm practice grenades with/without cartridges. The site at the MMR site contains targets of yet different sizes. In this work we apply our models to EMI data collected using the MetalMapper (MM) and 2 × 2 TEMTADS sensors. The data for each anomaly are inverted to extract estimates of the extrinsic and intrinsic parameters associated with each buried target. (The latter include the total volume magnetic source or NVMS, which relates to size, shape, and material properties; the former includes location, depth, and orientation). The estimated intrinsic parameters are then used for classification performed via library matching and the use of statistical classification algorithms; this process yielded prioritized dig-lists that were submitted to the Institute for Defense Analyses (IDA) for independent scoring. The models' classification performance is illustrated and assessed based on these independent evaluations.
5. BUILDING NO. 404, THERMO CHEMISTRY LABORATORY, LOOKING NORTHWEST AT ...
5. BUILDING NO. 404, THERMO CHEMISTRY LABORATORY, LOOKING NORTHWEST AT SOUTH SIDE OF BUILDING. BUILDING NO. 403 IN BACKGROUND RIGHT. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
Žuvela-Aloise, M
2017-03-01
The numerical model MUKLIMO_3 is used to simulate the urban climate of an imaginary city as an illustrative example to demonstrate that the residential areas with deprived socio-economic conditions can exhibit an enhanced heat load at night, and thus more disadvantageous environmental conditions, compared with the areas of higher socio-economic status. The urban climate modelling simulations differentiate between orographic, natural landscape, building and social effects, where social differences are introduced by selection of location, building type and amount of vegetation. The model results show that the increase of heat load can be found in the areas inhabited by the poor population as a combined effect of natural and anthropogenic factors. The unfavourable location in the city and the building type, consisting of high density, low housing with high fraction of pavement and small amount of vegetation contribute to the formation of excessive heat load. This abstract example shows that the enhancement of urban heat load can be linked to the concept of a socially stratified city and is independent of the historical development of any specific city.
NASA Astrophysics Data System (ADS)
Žuvela-Aloise, M.
2017-03-01
The numerical model MUKLIMO_3 is used to simulate the urban climate of an imaginary city as an illustrative example to demonstrate that the residential areas with deprived socio-economic conditions can exhibit an enhanced heat load at night, and thus more disadvantageous environmental conditions, compared with the areas of higher socio-economic status. The urban climate modelling simulations differentiate between orographic, natural landscape, building and social effects, where social differences are introduced by selection of location, building type and amount of vegetation. The model results show that the increase of heat load can be found in the areas inhabited by the poor population as a combined effect of natural and anthropogenic factors. The unfavourable location in the city and the building type, consisting of high density, low housing with high fraction of pavement and small amount of vegetation contribute to the formation of excessive heat load. This abstract example shows that the enhancement of urban heat load can be linked to the concept of a socially stratified city and is independent of the historical development of any specific city.
Cakmak, Ercan; Kirka, Michael M.; Watkins, Thomas R.; ...
2016-02-23
Theta-shaped specimens were additively manufactured out of Inconel 718 powders using an electron beam melting technique, as a model complex load bearing structure. We employed two different build strategies; producing two sets of specimens. Microstructural and micro-mechanical characterizations were performed using electron back-scatter, synchrotron x-ray and in-situ neutron diffraction techniques. In particular, the cross-members of the specimens were the focus of the synchrotron x-ray and in-situ neutron diffraction measurements. The build strategies employed resulted in the formation of distinct microstructures and crystallographic textures, signifying the importance of build-parameter manipulation for microstructural optimization. Large strain anisotropy of the different lattice planesmore » was observed during in-situ loading. Texture was concluded to have a distinct effect upon both the axial and transverse strain responses of the cross-members. In particular, the (200), (220) and (420) transverse lattice strains all showed unexpected overlapping trends in both builds. This was related to the strong {200} textures along the build/loading direction, providing agreement between the experimental and calculated results.« less
Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandez, Nicholas E.P.; Katipamula, Srinivas; Wang, Weimin
Commercial buildings in the United States use about 18 Quadrillion British thermal units (Quads) of primary energy annually . Studies have shown that as much as 30% of building energy consumption can be avoided by using more accurate sensing, using existing controls better, and deploying advanced controls; hence, the motivation for the work described in this report. Studies also have shown that 10% to 20% of the commercial building peak load can be temporarily managed/curtailed to provide grid services. Although many studies have indicated significant potential for reducing the energy consumption in commercial buildings, very few have documented the actualmore » savings. The studies that did so only provided savings at the whole building level, which makes it difficult to assess the savings potential of each individual measure deployed.« less
26. BUILDING NO. 271I, LEAD AZIDE PRIMER BUILDING, WESTERN CORNER ...
26. BUILDING NO. 271-I, LEAD AZIDE PRIMER BUILDING, WESTERN CORNER OF BUILDING SHOWING DOORS TO MIXING ROOM NO. 4. HAND CRANK VISIBLE AT RIGHT ROTATED SMALL POTS (CONTAINING LEAD AZIDE) IN MIXING ROOMS. - Picatinny Arsenal, 200 Area, Shell Component Loading, State Route 15 near I-80, Dover, Morris County, NJ
Estimation of Gust Response Factor for a Tall Building Model with 1:1.5 Plan Ratios
NASA Astrophysics Data System (ADS)
Sarath Kumar, H.; Selvi Rajan, S.
2017-08-01
The purpose of structural analysis and design of structures as per the building codes and its corresponding standers is to ensure the safety of structure under maximum loads and remains functional under service load. The structure which is designed under consideration of codes should also satisfy the durability, economy and aesthetics. The primary purpose of this work is to understand and compare design wind loads according with the Gust Response Factor as per codes of practices. The paper is concerned with the calculation of design wind loads on a rectangular building model (1:300gemetric scale) of size 10cm x 15cm x 70cm with an aspect ratio of 1:1.5:7 at eight different levels over the height under sub-urban terrain category for 00 angle and 900 angle wind incidence. The experiment id conducted in an atmospheric boundary layer wind tunnel facility of CSIR-Structural engineering Research centre, Chennai. The measured pressures are integrated to evaluate mean and RMS (Root, Mean, Square). Further the variation of above mentioned loads and response factor along the heights of the building with respect to sub-urban terrain condition are discussed and summarized in addition, the codal values of various international standards [IS-875 part-3 1987, IS-875 part-3 draft, ASCE-07] have also considered for comparison.
Daylighting performance and thermal implications of skylights vs. south-facing roof monitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenbaum, M.; Coldham, B.
1997-12-31
This paper reports the results of a comparison of skylights vs. south-facing roof monitors for daylighting the north wall zone of a 10,000 ft{sup 2} office building near Manchester, NH. A physical model was constructed and tested. Simultaneously, the building`s annual thermal performance was modeled with Energy-10 hourly simulation software, and its peak heating and cooling load performance was modeled with the Carrier Corp. Hourly Analysis Program (HAP). Apertures were built into the roof of the model, and several skylight and south-facing roof monitor configurations were tested in both clear and overcast conditions. A design goal was to have themore » building be daylit on overcast as well as clear days. This goal was based more on enhancement of the working environment than it was on electrical energy savings. Monitors with overhangs performed poorly in the overcast conditions--it was determined that 2.4 times as much monitor aperture was needed to yield equivalent light levels in overcast conditions. The thermal models showed that the annual heating and cooling energy cost for the building was the same for either strategy, but that peak cooling loads and peak heating loads were lower with the skylit version. The authors concluded that skylights were preferred over monitors in this application, due to similar annual energy costs, lower peak loads, and lower construction cost.« less
View of North End of Oxide Building Interior Including Roof ...
View of North End of Oxide Building Interior Including Roof and Wall Juncture and Crane Trolley - Hematite Fuel Fabrication Facility, Oxide Building & Oxide Loading Dock, 3300 State Road P, Festus, Jefferson County, MO
SUNREL Energy Simulation Software | Buildings | NREL
SUNREL Energy Simulation Software SUNREL Energy Simulation Software SUNREL® is a hourly building energy simulation program that aids in the design of small energy-efficient buildings where the loads are
NASA Astrophysics Data System (ADS)
Ghenai, C.; Bettayeb, M.
2017-11-01
Modelling, simulation, optimization and control strategies are used in this study to design a stand-alone solar PV/Fuel Cell/Battery/Generator hybrid power system to serve the electrical load of a commercial building. The main objective is to design an off grid energy system to meet the desired electric load of the commercial building with high renewable fraction, low emissions and low cost of energy. The goal is to manage the energy consumption of the building, reduce the associate cost and to switch from grid-tied fossil fuel power system to an off grid renewable and cleaner power system. Energy audit was performed in this study to determine the energy consumption of the building. Hourly simulations, modelling and optimization were performed to determine the performance and cost of the hybrid power configurations using different control strategies. The results show that the hybrid off grid solar PV/Fuel Cell/Generator/Battery/Inverter power system offers the best performance for the tested system architectures. From the total energy generated from the off grid hybrid power system, 73% is produced from the solar PV, 24% from the fuel cell and 3% from the backup Diesel generator. The produced power is used to meet all the AC load of the building without power shortage (<0.1%). The hybrid power system produces 18.2% excess power that can be used to serve the thermal load of the building. The proposed hybrid power system is sustainable, economically viable and environmentally friendly: High renewable fraction (66.1%), low levelized cost of energy (92 /MWh), and low carbon dioxide emissions (24 kg CO2/MWh) are achieved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunn, B. D.; Diamond, S. C.; Bennett, G. A.
1977-10-01
A set of computer programs, called Cal-ERDA, is described that is capable of rapid and detailed analysis of energy consumption in buildings. A new user-oriented input language, named the Building Design Language (BDL), has been written to allow simplified manipulation of the many variables used to describe a building and its operation. This manual provides the user with information necessary to understand in detail the Cal-ERDA set of computer programs. The new computer programs described include: an EXECUTIVE Processor to create computer system control commands; a BDL Processor to analyze input instructions, execute computer system control commands, perform assignments andmore » data retrieval, and control the operation of the LOADS, SYSTEMS, PLANT, ECONOMICS, and REPORT programs; a LOADS analysis program that calculates peak (design) zone and hourly loads and the effect of the ambient weather conditions, the internal occupancy, lighting, and equipment within the building, as well as variations in the size, location, orientation, construction, walls, roofs, floors, fenestrations, attachments (awnings, balconies), and shape of a building; a Heating, Ventilating, and Air-Conditioning (HVAC) SYSTEMS analysis program capable of modeling the operation of HVAC components including fans, coils, economizers, humidifiers, etc.; 16 standard configurations and operated according to various temperature and humidity control schedules. A plant equipment program models the operation of boilers, chillers, electrical generation equipment (diesel or turbines), heat storage apparatus (chilled or heated water), and solar heating and/or cooling systems. An ECONOMIC analysis program calculates life-cycle costs. A REPORT program produces tables of user-selected variables and arranges them according to user-specified formats. A set of WEATHER ANALYSIS programs manipulates, summarizes and plots weather data. Libraries of weather data, schedule data, and building data were prepared.« less
Curvilinear steel elements in load-bearing structures of high-rise building spatial frames
NASA Astrophysics Data System (ADS)
Ibragimov, Alexander; Danilov, Alexander
2018-03-01
The application of curvilinear elements in load-bearing metal structures of high-rise buildings supposes ensuring of their bearing capacity and serviceability. There may exist a great variety of shapes and orientations of such structural elements. In particular, it may be various flat curves of an open or closed oval profile such as circular or parabolic arch or ellipse. The considered approach implies creating vast internal volumes without loss in the load-bearing capacity of the frame. The basic concept makes possible a wide variety of layout and design solutions. The presence of free internal spaces of large volume in "skyscraper" type buildings contributes to resolving a great number of problems, including those of communicative nature. The calculation results confirm the basic assumptions.
1984-04-15
are left to right, M739 , M564, and M577 fuzes. Although the * "image is not as sharp as is possible, due to the low L/D (18) and a slight misalignment...of the specimens (see Figure 16N for example), several components/parts are shown on the NR which would not be imaged on the X-rays. In the M739 such...POINT DETONATING: M739 CRS AR iOiR ASS SETTNG SEEVEASSYHIM Figure ~ ~ ~ ~ ~ ~ HOE INA CRSDigasofAR itDtnaigFz S AASYBOY OLE A35 %E ILL 0 0 -- Y, zaZ
XM587E2/XM724 Electronic Time Fuzes: Developmental Test/Operational Test (DT/OT) II Test Phase
1979-11-01
unit - da.- aged setbac* spring Sunit - damAged setback pia 140 .4 C) Twenty-five units were subjected to variable testing "to determine tho G level...SAXIP ACCEPT REJECT NO. Ttf7l KSCRIFTI( AG sin4 go flj-. cEI~ *S-FOOTMOP TEsT o 0 (DROPPED IN FIVE DIFFRNT csIllvrATIaNS -- 1 PER OCRIMP... ascue bya i i*ctet FAILURE AND ACTION REPORT 71134 Jj 7113 .I ,...,-... 7 wow o ft.-I I The unIt will not tht. bte the the scalet inpf t to the.uner h
Study of Fuze Structure and Reliability Design Based on the Direct Search Method
NASA Astrophysics Data System (ADS)
Lin, Zhang; Ning, Wang
2017-03-01
Redundant design is one of the important methods to improve the reliability of the system, but mutual coupling of multiple factors is often involved in the design. In my study, Direct Search Method is introduced into the optimum redundancy configuration for design optimization, in which, the reliability, cost, structural weight and other factors can be taken into account simultaneously, and the redundant allocation and reliability design of aircraft critical system are computed. The results show that this method is convenient and workable, and applicable to the redundancy configurations and optimization of various designs upon appropriate modifications. And this method has a good practical value.
Wind/seismic comparisons for upgrading existing structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giller, R.A.
1989-10-01
This paper depicts the analysis procedures and methods used to evaluate three existing building structures for extreme wind loads. The three structures involved in this evaluation are located at the US Department of Energy's Hanford Site near Richland, Washington. This site is characterized by open flat grassland with few surrounding obstructions and has extreme winds in lieu of tornados as a design basis accident condition. This group of buildings represents a variety of construction types, including a concrete stack, a concrete load-bearing wall structure, and a rigid steel-frame building. The three structures included in this group have recently been evaluatedmore » for response to the design basis earthquake that included non-linear time history effects. The resulting loads and stresses from the wind analyses were compared to the loads and stresses resulting from seismic analyses. This approach eliminated the need to prepare additional capacity calculations that were already contained in the seismic evaluations. 4 refs., 5 figs., 5 tabs.« less
Building Energy Management Open Source Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
This is the repository for Building Energy Management Open Source Software (BEMOSS), which is an open source operating system that is engineered to improve sensing and control of equipment in small- and medium-sized commercial buildings. BEMOSS offers the following key features: (1) Open source, open architecture – BEMOSS is an open source operating system that is built upon VOLTTRON – a distributed agent platform developed by Pacific Northwest National Laboratory (PNNL). BEMOSS was designed to make it easy for hardware manufacturers to seamlessly interface their devices with BEMOSS. Software developers can also contribute to adding additional BEMOSS functionalities and applications.more » (2) Plug & play – BEMOSS was designed to automatically discover supported load controllers (including smart thermostats, VAV/RTUs, lighting load controllers and plug load controllers) in commercial buildings. (3) Interoperability – BEMOSS was designed to work with load control devices form different manufacturers that operate on different communication technologies and data exchange protocols. (4) Cost effectiveness – Implementation of BEMOSS deemed to be cost-effective as it was built upon a robust open source platform that can operate on a low-cost single-board computer, such as Odroid. This feature could contribute to its rapid deployment in small- or medium-sized commercial buildings. (5) Scalability and ease of deployment – With its multi-node architecture, BEMOSS provides a distributed architecture where load controllers in a multi-floor and high occupancy building could be monitored and controlled by multiple single-board computers hosting BEMOSS. This makes it possible for a building engineer to deploy BEMOSS in one zone of a building, be comfortable with its operation, and later on expand the deployment to the entire building to make it more energy efficient. (6) Ability to provide local and remote monitoring – BEMOSS provides both local and remote monitoring ability with role-based access control. (7) Security – In addition to built-in security features provided by VOLTTRON, BEMOSS provides enhanced security features, including BEMOSS discovery approval process, encrypted core-to-node communication, thermostat anti-tampering feature and many more. (8) Support from the Advisory Committee – BEMOSS was developed in consultation with an advisory committee from the beginning of the project. BEMOSS advisory committee comprises representatives from 22 organizations from government and industry.« less
Looking Northeast in Oxide Building at Reactors on Second Floor ...
Looking Northeast in Oxide Building at Reactors on Second Floor Including Reactor One (Left) and Reactor Two (Right) - Hematite Fuel Fabrication Facility, Oxide Building & Oxide Loading Dock, 3300 State Road P, Festus, Jefferson County, MO
Transactive Control of Commercial Buildings for Demand Response
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hao, He; Corbin, Charles D.; Kalsi, Karanjit
Transactive control is a type of distributed control strategy that uses market mechanism to engage self-interested responsive loads to achieve power balance in the electrical power grid. In this paper, we propose a transactive control approach of commercial building Heating, Ventilation, and Air- Conditioning (HVAC) systems for demand response. We first describe the system models, and identify their model parameters using data collected from Systems Engineering Building (SEB) located on our Pacific Northwest National Laboratory (PNNL) campus. We next present a transactive control market structure for commercial building HVAC system, and describe its agent bidding and market clearing strategies. Severalmore » case studies are performed in a simulation environment using Building Control Virtual Test Bed (BCVTB) and calibrated SEB EnergyPlus model. We show that the proposed transactive control approach is very effective at peak clipping, load shifting, and strategic conservation for commercial building HVAC systems.« less
Constructive systems, load-bearing and enclosing structures of high-rise buildings
NASA Astrophysics Data System (ADS)
Anatol'evna Korol', Elena; Olegovna Kustikova, Yuliya
2018-03-01
As the height of the building increases, loads on load-carrying structures increase dramatically, and as a result of the development of high-rise construction, several structural systems of such buildings have been developed: frame, frame-frame, cross-wall, barrel, box-type, box-to-wall ("pipe in pipe", "Trumpet in the farm"), etc. In turn, the barrel systems have their own versions: cantilever support of the ceilings on the trunk, suspension of the outer part of the overlap to the upper carrying console "hanging house" or its support by means of the walls on the lower bearing cantilever, intermediate position of the supporting cantilevers in height to the floor, from a part of floors. The object of the study are the structural solutions of high-rise buildings. The subject of the study is the layout of structural schemes of high-rise buildings, taking into account the main parameters - altitude (height), natural climatic conditions of construction, materials of structural elements and their physical and mechanical characteristics. The purpose of the study is to identify the features and systematization of structural systems of high-rise buildings and the corresponding structural elements. The results of the research make it possible, at the stage of making design decisions, to establish rational parameters for the correspondence between the structural systems of high-rise buildings and their individual elements.
Lateral Displacement and Shear Lag Effect of Combination of Diagrid-Frame
NASA Astrophysics Data System (ADS)
Abd. Samat, Roslida; Chua, Fong Teng; Mustakim, Nur Akmal Hayati Mohd; Saad, Sariffuddin; Abu Bakar, Suhaimi
2018-03-01
Diagrid system, which is the portmanteau of diagonal grid member, is an exterior lateral load resisting system for tall building that has gained a wide acceptance in the design of tall buildings. There is abundance of researches that studied the efficiency of diagrid systems, which are constructed from the ground level to the top of the buildings in resisting the lateral load. Nevertheless, no study had been performed on the effectiveness of the diagrid that is constructed above other tall building systems despite the existence of a few buildings in the world that employ such system. The objective of this research is to understand the behavior of the lateral displacement and shear lag effect due to wind load when the diagrid structure is constructed above a frame. Models of 60-story buildings with a footprint of 36m x 36m were analyzed by using Staad.Pro software. The level where the diagrid members started was altered. The lateral displacement was reduced to 60.6 percent and 41 percent of the lateral displacement of a building with full frame system when the combination of frame-diagrid that had the diagrid started at Level 1 and Level 45, respectively were employed. Furthermore, the shear lag ratio was reduced from 1.7 to 1.3 when the level where the diagrid started was increased from Level 1 to Level 45.
Solar thermal heating and cooling. A bibliography with abstracts
NASA Technical Reports Server (NTRS)
Arenson, M.
1979-01-01
This bibliographic series cites and abstracts the literature and technical papers on the heating and cooling of buildings with solar thermal energy. Over 650 citations are arranged in the following categories: space heating and cooling systems; space heating and cooling models; building energy conservation; architectural considerations, thermal load computations; thermal load measurements, domestic hot water, solar and atmospheric radiation, swimming pools; and economics.
Analysis and Representation of Miscellaneous Electric Loads in NEMS
2017-01-01
Miscellaneous Electric Loads (MELs) comprise a growing portion of delivered energy consumption in residential and commercial buildings. Miscellaneous end uses—including televisions, personal computers, security systems, data center servers, and many other devices—have continued to penetrate into building-related market segments. Part of this proliferation of devices and equipment can be attributed to increased service demand for entertainment, computing, and convenience appliances.
Simulated building energy demand biases resulting from the use of representative weather stations
Burleyson, Casey D.; Voisin, Nathalie; Taylor, Z. Todd; ...
2017-11-06
Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. Here, we quantify the potential reduction in temperature and load biases from using an increasing number of weather stations over the western U.S. Our novel approach is based on deriving temperature and load time series using incrementally more weather stations, ranging frommore » 8 to roughly 150, to evaluate the ability to capture weather patterns across different seasons. Using 8 stations across the western U.S., one from each IECC climate zone, results in an average absolute summertime temperature bias of ~4.0 °C with respect to a high-resolution gridded dataset. The mean absolute bias drops to ~1.5 °C using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.5%. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Using 8 representative weather stations can lead to a 20–40% bias of peak building loads during both summer and winter, a significant error for capacity expansion planners who may use these types of simulations. Using weather stations close to population centers reduces both mean and peak load biases. Our approach could be used by others designing aggregate building simulations to understand the sensitivity to their choice of weather stations used to drive the models.« less
Simulated building energy demand biases resulting from the use of representative weather stations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burleyson, Casey D.; Voisin, Nathalie; Taylor, Z. Todd
Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. Here, we quantify the potential reduction in temperature and load biases from using an increasing number of weather stations over the western U.S. Our novel approach is based on deriving temperature and load time series using incrementally more weather stations, ranging frommore » 8 to roughly 150, to evaluate the ability to capture weather patterns across different seasons. Using 8 stations across the western U.S., one from each IECC climate zone, results in an average absolute summertime temperature bias of ~4.0 °C with respect to a high-resolution gridded dataset. The mean absolute bias drops to ~1.5 °C using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.5%. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Using 8 representative weather stations can lead to a 20–40% bias of peak building loads during both summer and winter, a significant error for capacity expansion planners who may use these types of simulations. Using weather stations close to population centers reduces both mean and peak load biases. Our approach could be used by others designing aggregate building simulations to understand the sensitivity to their choice of weather stations used to drive the models.« less
VOLTTRON-Based System for Providing Ancillary Services with Residential Building Loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Xin
2016-07-01
Ancillary services entail controlled modulation of building equipment to maintain a stable balance of generation and load in the power system. Ancillary services include frequency regulation and contingency reserves, whose acting time ranges from several seconds to several minutes. Many pilot studies have been implemented to use industrial loads to provide ancillary services, and some have explored services from commercial building loads or electric vehicle charging loads. Residential loads, such as space conditioning and water heating, represent a largely untapped resource for providing ancillary services. The residential building sector accounts for a significant fraction of the total electricity use inmore » the United States. Many loads in residential buildings are flexible and could potentially be curtailed or shifted at the request of the grid. However, there are many barriers that prevent residential loads being widely used for ancillary services. One of the major technical barriers is the lack of communication capabilities between end-use devices and the grid. End-use devices need to be able to receive the automatic generation control (AGC) signal from the grid operator and supply certain types of telemetry to verify response. With the advance of consumer electronics, communication-enabled, or 'connected,' residential equipment has emerged to overcome the communication barrier. However, these end-use devices have introduced a new interoperability challenge due to the existence of numerous standards and communication protocols among different end devices. In this paper, we present a VOLTTRON-based system that overcomes these technical challenges and provides ancillary services with residential loads. VOLTTRON is an open-source control and sensing platform for building energy management, facilitating interoperability solutions for end devices. We have developed drivers to communicate and control different types of end devices through standard-based interfaces, manufacturer-provided application programming interfaces, and proprietary communication interfaces. We document the ability to manage nine appliances, using four different standards or proprietary communication methods. A hardware-in-the-loop test was performed in a laboratory environment where the loads of a laboratory home and a large number of simulated homes are controlled by an aggregator. Upon receipt of an AGC signal, the VOLTTRON home energy management system (HEMS) of the laboratory home adjusts the end-device controls based on the comfort criteria set by the end users and sends telemetry to the aggregator to verify response. The aggregator then sends the AGC signal to other simulated homes in attempts to match the utility request as closely as possible. Frequency regulation is generally considered a higher value service than other ancillary services but it is also more challenging due to the constraint of short response time. A frequency regulation use case has been implemented with the regulation signals sent every 10 seconds. Experimental results indicate that the VOLTTRON-controlled residential loads are able to be controlled with sufficient fidelity to enable an aggregator to meet frequency regulation requirements. Future work is warranted, such as understanding the impact of this type of control on equipment life, and market requirements needed to open up residential loads to ancillary service aggregators.« less
Looking Southwest at First Floor View of Oxide Building Interior ...
Looking Southwest at First Floor View of Oxide Building Interior Including Steam Lines, Weigh and Sample Hood, and Superheater - Hematite Fuel Fabrication Facility, Oxide Building & Oxide Loading Dock, 3300 State Road P, Festus, Jefferson County, MO
76. Neg. No. F58, Apr 13, 1930, INTERIORASSEMBLY BUILDING, BURNOFF, ...
76. Neg. No. F-58, Apr 13, 1930, INTERIOR-ASSEMBLY BUILDING, BURNOFF, LOAD END OF ENAMEL OVEN - Ford Motor Company Long Beach Assembly Plant, Assembly Building, 700 Henry Ford Avenue, Long Beach, Los Angeles County, CA
Reducing Heat Gains and Cooling Loads Through Roof Structure Configurations of A House in Medan
NASA Astrophysics Data System (ADS)
Handayani Lubis, Irma; Donny Koerniawan, Mochamad
2018-05-01
Heat gains and heat losses through building surfaces are the main factors that determine the building’s cooling and heating loads. Roof as a building surface that has the most exposed area to the sun, contribute most of heat gains in the building. Therefore, the amount of solar heat gains on the roofs need to be minimized by roof structure configurations. This research aims to discover the optimization of roof structure configurations (coating material, structure material, inclination, overhang, and insulation) as one of passive design strategies that reduce heat gains and cooling loads of a house in Medan. The result showed that case four, white-painted metal roof combined with 45° roof pitched, 1.5m overhang, and addition of insulation, indicates the minimum heat gains production and the less cooling loads during clear sky day but not in the overcast sky condition. In conclusion, heat gains and cooling loads of a house in Medan could be diminished during clear sky day by the addition of roof coating with high reflectance low solar absorbtance, the slope roof, the extension of wider veranda, and the addition of insulation in the roof structure.
NASA Technical Reports Server (NTRS)
Davis, E. S.; French, R. L.; Hirshberg, A. S.
1976-01-01
Plausible future market scenarios for solar heating and cooling systems into buildings in the area served by the Southern California Edison Company. A range of plausible estimates for the number of solar systems which might be installed and the electrical energy which might be displaced by energy from these systems are provided. The effect on peak electrical load was not explicitly calculated but preliminary conclusions concerning peak load can be inferred from the estimates presented. Two markets are investigated: the single family market and the large power commercial market.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, Danny S.; Cummings, Jamie E.; Vieira, Robin K.
Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.
NASA Astrophysics Data System (ADS)
Hassan, Wael Mohammed
Beam-column joints in concrete buildings are key components to ensure structural integrity of building performance under seismic loading. Earthquake reconnaissance has reported the substantial damage that can result from inadequate beam-column joints. In some cases, failure of older-type corner joints appears to have led to building collapse. Since the 1960s, many advances have been made to improve seismic performance of building components, including beam-column joints. New design and detailing approaches are expected to produce new construction that will perform satisfactorily during strong earthquake shaking. Much less attention has been focused on beam-column joints of older construction that may be seismically vulnerable. Concrete buildings constructed prior to developing details for ductility in the 1970s normally lack joint transverse reinforcement. The available literature concerning the performance of such joints is relatively limited, but concerns about performance exist. The current study aimed to improve understanding and assessment of seismic performance of unconfined exterior and corner beam-column joints in existing buildings. An extensive literature survey was performed, leading to development of a database of about a hundred tests. Study of the data enabled identification of the most important parameters and the effect of each parameter on the seismic performance. The available analytical models and guidelines for strength and deformability assessment of unconfined joints were surveyed and evaluated. In particular, The ASCE 41 existing building document proved to be substantially conservative in joint shear strength estimation. Upon identifying deficiencies in these models, two new joint shear strength models, a bond capacity model, and two axial capacity models designed and tailored specifically for unconfined beam-column joints were developed. The proposed models strongly correlated with previous test results. In the laboratory testing phase of the current study, four full-scale corner beam-column joint subassemblies, with slab included, were designed, built, instrumented, tested, and analyzed. The specimens were tested under unidirectional and bidirectional displacement-controlled quasi-static loading that incorporated varying axial loads that simulated overturning seismic moment effects. The axial loads varied between tension and high compression loads reaching about 50% of the column axial capacity. The test parameters were axial load level, loading history, joint aspect ratio, and beam reinforcement ratio. The test results proved that high axial load increases joint shear strength and decreases the deformability of joints failing in pure shear failure mode without beam yielding. On the contrary, high axial load did not affect the strength of joints failing in shear after significant beam yielding; however, it substantially increased their displacement ductility. Joint aspect ratio proved to be instrumental in deciding joint shear strength; that is the deeper the joint the lower the shear strength. Bidirectional loading reduced the apparent strength of the joint in the uniaxial principal axes. However, circular shear strength interaction is an appropriate approximation to predict the biaxial strength. The developed shear strength models predicted successfully the strength of test specimens. Based on the literature database investigation, the shear and axial capacity models developed and the test results of the current study, an analytical finite element component model based on a proposed joint shear stress-rotation backbone constitutive curve was developed to represent the behavior of unconfined beam-column joints in computer numerical simulations of concrete frame buildings. The proposed finite element model included the effect of axial load, mode of joint failure, joint aspect ratio and axial capacity of joint. The proposed backbone curve along with the developed joint element exhibited high accuracy in simulating the test response of the current test specimens as well as previous test joints. Finally, a parametric study was conducted to assess the axial failure vulnerability of unconfined beam-column joints based on the developed shear and axial capacity models. This parametric study compared the axial failure potential of unconfined beam-column joint with that of shear critical columns to provide a preliminary insight into the axial collapse vulnerability of older-type buildings during intense ground shaking.
12. Threequarter view of southwest corner of building 500, Gwing, ...
12. Three-quarter view of southwest corner of building 500, G-wing, and loading dock looking northeast, from Apollo Drive - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE
4. BUILDING NO. 404, THERMO CHEMISTRY LABORATORY, LOOKING SOUTHEAST AT ...
4. BUILDING NO. 404, THERMO CHEMISTRY LABORATORY, LOOKING SOUTHEAST AT SOUTH AND WEST SIDES OF BUILDING. ORIGINALLY USED AS A STOREHOUSE. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
94. Neg. No. F130, Sep 24, 1931, EXTERIOROFFICE BUILDING AND ...
94. Neg. No. F-130, Sep 24, 1931, EXTERIOR-OFFICE BUILDING AND ASSEMBLY BUILDING, WEST SIDE, SHOWING TRUCKS AND TRAILORS LOADED WITH NEW TRUCKS DISPLAYING SIGNS 'MORE FORDS FOR HOOVER DAM' - Ford Motor Company Long Beach Assembly Plant, Assembly Building, 700 Henry Ford Avenue, Long Beach, Los Angeles County, CA
Gerber, Daniel L.; Vossos, Vagelis; Feng, Wei; ...
2017-06-12
Direct current (DC) power distribution has recently gained traction in buildings research due to the proliferation of on-site electricity generation and battery storage, and an increasing prevalence of internal DC loads. The research discussed in this paper uses Modelica-based simulation to compare the efficiency of DC building power distribution with an equivalent alternating current (AC) distribution. The buildings are all modeled with solar generation, battery storage, and loads that are representative of the most efficient building technology. A variety of paramet ric simulations determine how and when DC distribution proves advantageous. These simulations also validate previous studies that use simplermore » approaches and arithmetic efficiency models. This work shows that using DC distribution can be considerably more efficient: a medium sized office building using DC distribution has an expected baseline of 12% savings, but may also save up to 18%. In these results, the baseline simulation parameters are for a zero net energy (ZNE) building that can island as a microgrid. DC is most advantageous in buildings with large solar capacity, large battery capacity, and high voltage distribution.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerber, Daniel L.; Vossos, Vagelis; Feng, Wei
Direct current (DC) power distribution has recently gained traction in buildings research due to the proliferation of on-site electricity generation and battery storage, and an increasing prevalence of internal DC loads. The research discussed in this paper uses Modelica-based simulation to compare the efficiency of DC building power distribution with an equivalent alternating current (AC) distribution. The buildings are all modeled with solar generation, battery storage, and loads that are representative of the most efficient building technology. A variety of paramet ric simulations determine how and when DC distribution proves advantageous. These simulations also validate previous studies that use simplermore » approaches and arithmetic efficiency models. This work shows that using DC distribution can be considerably more efficient: a medium sized office building using DC distribution has an expected baseline of 12% savings, but may also save up to 18%. In these results, the baseline simulation parameters are for a zero net energy (ZNE) building that can island as a microgrid. DC is most advantageous in buildings with large solar capacity, large battery capacity, and high voltage distribution.« less
An analysis of travel costs on transport of load and nest building in golden hamster.
Guerra, Rogerio F.; Ades, Cesar
2002-03-28
We investigated the effects of travel costs on transporting nest material and nest-building activity in golden hamsters. Nest-deprived animals were submitted to run alleys 30, 90 and 180 cm long to access a source containing paper strips as nest material (Experiment 1) or were submitted to the same travel costs in 24-h experimental sessions (Experiment 2). We noted that increased travel costs were related to a decreased number of trips to the source, larger amounts (cm(2)) of nest material transported per trip (although total loads also decreased in longer alleys), longer intervals between trips, and increased time spent at the source and in nest building activity. Foraging efficiency (i.e. size of load divided by the time spent at the source) decreased as a function of travel costs, and animals transported their loads in two fundamental ways: in 30-cm alleys, they simply used their mouth to pull the paper strips, but in 90- or 180-cm alleys they transported the loads in their cheek pouches. The animals were faster when returning to the home-cage and their running speed (cm/s) increased as a function of the length of the alley, showing that animals are under different environmental pressures when searching for resources and subsequently running back with the load to the nest. Both male and female subjects were sensitive to travel costs, but males engaged in nest building activity more promptly and exhibited higher mean performances in most measures. We conclude that nest material is a good reinforcer, and our major results are in accordance with the predictions of microeconomic and optimal foraging theories.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Eric; Withers, Chuck; McIlvaine, Janet
The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. Themore » problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.« less
Extreme winds and tornadoes: design and evaluation of buildings and structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, J.R.
1985-01-01
The general provisions of ANSI A58.1-1982 are explained in detail. As mentioned above, these procedures may be used to determine design wind loads on structures from extreme winds, hurricane and tornado winds. Treatment of atmospheric pressure change loads are discussed, including recommendations for venting a building, if necessary, and the effects of rate of pressure change on HVAC systems. Finally, techniques for evaluating existing facilities are described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Nan; Marnay, Chris; Firestone, Ryan
The August 2003 blackout of the northeastern U.S. and CANADA caused great economic losses and inconvenience to New York City and other affected areas. The blackout was a warning to the rest of the world that the ability of conventional power systems to meet growing electricity demand is questionable. Failure of large power systems can lead to serious emergencies. Introduction of on-site generation, renewable energy such as solar and wind power and the effective utilization of exhaust heat is needed, to meet the growing energy demands of the residential and commercial sectors. Additional benefit can be achieved by integrating thesemore » distributed technologies into distributed energy resource (DER) systems. This work demonstrates a method for choosing and designing economically optimal DER systems. An additional purpose of this research is to establish a database of energy tariffs, DER technology cost and performance characteristics, and building energy consumption for Japan. This research builds on prior DER studies at the Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) and with their associates in the Consortium for Electric Reliability Technology Solutions (CERTS) and operation, including the development of the microgrid concept, and the DER selection optimization program, the Distributed Energy Resources Customer Adoption Model (DER-CAM). DER-CAM is a tool designed to find the optimal combination of installed equipment and an idealized operating schedule to minimize a site's energy bills, given performance and cost data on available DER technologies, utility tariffs, and site electrical and thermal loads over a test period, usually an historic year. Since hourly electric and thermal energy data are rarely available, they are typically developed by building simulation for each of six end use loads used to model the building: electric-only loads, space heating, space cooling, refrigeration, water heating, and natural-gas-only loads. DER-CAM provides a global optimization, albeit idealized, that shows how the necessary useful energy loads can be provided for at minimum cost by selection and operation of on-site generation, heat recovery, cooling, and efficiency improvements. This study examines five prototype commercial buildings and uses DER-CAM to select the economically optimal DER system for each. The five building types are office, hospital, hotel, retail, and sports facility. Each building type was considered for both 5,000 and 10,000 square meter floor sizes. The energy consumption of these building types is based on building energy simulation and published literature. Based on the optimization results, energy conservation and the emissions reduction were also evaluated. Furthermore, a comparison study between Japan and the U.S. has been conducted covering the policy, technology and the utility tariffs effects on DER systems installations. This study begins with an examination of existing DER research. Building energy loads were then generated through simulation (DOE-2) and scaled to match available load data in the literature. Energy tariffs in Japan and the U.S. were then compared: electricity prices did not differ significantly, while commercial gas prices in Japan are much higher than in the U.S. For smaller DER systems, the installation costs in Japan are more than twice those in the U.S., but this difference becomes smaller with larger systems. In Japan, DER systems are eligible for a 1/3 rebate of installation costs, while subsidies in the U.S. vary significantly by region and application. For 10,000 m{sup 2} buildings, significant decreases in fuel consumption, carbon emissions, and energy costs were seen in the economically optimal results. This was most noticeable in the sports facility, followed the hospital and hotel. This research demonstrates that office buildings can benefit from CHP, in contrast to popular opinion. For hospitals and sports facilities, the use of waste heat is particularly effective for water and space heating. For the other building types, waste heat is most effectively used for both heating and cooling. The same examination was done for the 5,000 m{sup 2} buildings. Although CHP installation capacity is smaller and the payback periods are longer, economic, fuel efficiency, and environmental benefits are still seen. While these benefits remain even when subsidies are removed, the increased installation costs lead to lower levels of installation capacity and thus benefit.« less
NASA Astrophysics Data System (ADS)
Flores, Robert Joseph
Distributed generation can provide many benefits over traditional central generation such as increased reliability and efficiency while reducing emissions. Despite these potential benefits, distributed generation is generally not purchased unless it reduces energy costs. Economic dispatch strategies can be designed such that distributed generation technologies reduce overall facility energy costs. In this thesis, a microturbine generator is dispatched using different economic control strategies, reducing the cost of energy to the facility. Several industrial and commercial facilities are simulated using acquired electrical, heating, and cooling load data. Industrial and commercial utility rate structures are modeled after Southern California Edison and Southern California Gas Company tariffs and used to find energy costs for the simulated buildings and corresponding microturbine dispatch. Using these control strategies, building models, and utility rate models, a parametric study examining various generator characteristics is performed. An economic assessment of the distributed generation is then performed for both the microturbine generator and parametric study. Without the ability to export electricity to the grid, the economic value of distributed generation is limited to reducing the individual costs that make up the cost of energy for a building. Any economic dispatch strategy must be built to reduce these individual costs. While the ability of distributed generation to reduce cost depends of factors such as electrical efficiency and operations and maintenance cost, the building energy demand being serviced has a strong effect on cost reduction. Buildings with low load factors can accept distributed generation with higher operating costs (low electrical efficiency and/or high operations and maintenance cost) due to the value of demand reduction. As load factor increases, lower operating cost generators are desired due to a larger portion of the building load being met in an effort to reduce demand. In addition, buildings with large thermal demand have access to the least expensive natural gas, lowering the cost of operating distributed generation. Recovery of exhaust heat from DG reduces cost only if the buildings thermal demand coincides with the electrical demand. Capacity limits exist where annual savings from operation of distributed generation decrease if further generation is installed. For low operating cost generators, the approximate limit is the average building load. This limit decreases as operating costs increase. In addition, a high capital cost of distributed generation can be accepted if generator operating costs are low. As generator operating costs increase, capital cost must decrease if a positive economic performance is desired.
Measuring and Understanding the Energy Use Signatures of a Bank Building
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, YuLong; Liu, Bing; Athalye, Rahul A.
The Pacific Northwest National Laboratory measured and analyzed the energy end-use patterns in a bank building located in the north-eastern United States. This work was performed in collaboration with PNC Financial Service Group under the US DOE’s Commercial Building Partnerships Program. This paper presents the metering study and the results of the metered data analysis. It provides a benchmark for the energy use of different bank-related equipments. The paper also reveals the importance of metering in fully understanding building loads and indentifying opportunities for energy efficiency improvements that will have impacts across PNC’s portfolio of buildings and were crucial tomore » reducing receptacle loads in the design of a net-zero bank branches. PNNL worked with PNC to meter a 4,000 ft2 bank branch in the state of Pennsylvania. 71 electrical circuits were monitored and 25 stand-alone watt-hour meters were installed at the bank. These meters monitored the consumption of all interior and exterior lighting, receptacle loads, service water heating, and the HVAC rooftop unit at a 5-minute sampling interval from November 2009 to November 2010. A total of over 8 million data records were generated, which were then analyzed to produce the end-use patterns, daily usage profiles, rooftop unit usage cycles, and inputs for calibrating the energy model of the building.« less
NASA Astrophysics Data System (ADS)
Biyanto, T. R.; Matradji; Syamsi, M. N.; Fibrianto, H. Y.; Afdanny, N.; Rahman, A. H.; Gunawan, K. S.; Pratama, J. A. D.; Malwindasari, A.; Abdillah, A. I.; Bethiana, T. N.; Putra, Y. A.
2017-11-01
The development of green building has been growing in both design and quality. The development of green building was limited by the issue of expensive investment. Actually, green building can reduce the energy usage inside the building especially in utilization of cooling system. External load plays major role in reducing the usage of cooling system. External load is affected by type of wall sheathing, glass and roof. The proper selection of wall, type of glass and roof material are very important to reduce external load. Hence, the optimization of energy efficiency and conservation in green building design is required. Since this optimization consist of integer and non-linear equations, this problem falls into Mixed-Integer-Non-Linear-Programming (MINLP) that required global optimization technique such as stochastic optimization algorithms. In this paper the optimized variables i.e. type of glass and roof were chosen using Duelist, Killer-Whale and Rain-Water Algorithms to obtain the optimum energy and considering the minimal investment. The optimization results exhibited the single glass Planibel-G with the 3.2 mm thickness and glass wool insulation provided maximum ROI of 36.8486%, EUI reduction of 54 kWh/m2·year, CO2 emission reduction of 486.8971 tons/year and reduce investment of 4,078,905,465 IDR.
Effects of internal gain assumptions in building energy calculations
NASA Astrophysics Data System (ADS)
Christensen, C.; Perkins, R.
1981-01-01
The utilization of direct solar gains in buildings can be affected by operating profiles, such as schedules for internal gains, thermostat controls, and ventilation rates. Building energy analysis methods use various assumptions about these profiles. The effects of typical internal gain assumptions in energy calculations are described. Heating and cooling loads from simulations using the DOE 2.1 computer code are compared for various internal gain inputs: typical hourly profiles, constant average profiles, and zero gain profiles. Prototype single-family-detached and multifamily-attached residential units are studied with various levels of insulation and infiltration. Small detached commercial buildings and attached zones in large commercial buildings are studied with various levels of internal gains. The results indicate that calculations of annual heating and cooling loads are sensitive to internal gains, but in most cases are relatively insensitive to hourly variations in internal gains.
NASA Astrophysics Data System (ADS)
Kamal, Rajeev
Buildings contribute a significant part to the electricity demand profile and peak demand for the electrical utilities. The addition of renewable energy generation adds additional variability and uncertainty to the power system. Demand side management in the buildings can help improve the demand profile for the utilities by shifting some of the demand from peak to off-peak times. Heating, ventilation and air-conditioning contribute around 45% to the overall demand of a building. This research studies two strategies for reducing the peak as well as shifting some demand from peak to off-peak periods in commercial buildings: 1. Use of gas heat pumps in place of electric heat pumps, and 2. Shifting demand for air conditioning from peak to off-peak by thermal energy storage in chilled water and ice. The first part of this study evaluates the field performance of gas engine-driven heat pumps (GEHP) tested in a commercial building in Florida. Four GEHP units of 8 Tons of Refrigeration (TR) capacity each providing air-conditioning to seven thermal zones in a commercial building, were instrumented for measuring their performance. The operation of these GEHPs was recorded for ten months, analyzed and compared with prior results reported in the literature. The instantaneous COPunit of these systems varied from 0.1 to 1.4 during typical summer week operation. The COP was low because the gas engines for the heat pumps were being used for loads that were much lower than design capacity which resulted in much lower efficiencies than expected. The performance of equivalent electric heat pump was simulated from a building energy model developed to mimic the measured building loads. An economic comparison of GEHPs and conventional electrical heat pumps was done based on the measured and simulated results. The average performance of the GEHP units was estimated to lie between those of EER-9.2 and EER-11.8 systems. The performance of GEHP systems suffers due to lower efficiency at part load operation. The study highlighted the need for optimum system sizing for GEHP/HVAC systems to meet the building load to obtain better performance in buildings. The second part of this study focusses on using chilled water or ice as thermal energy storage for shifting the air conditioning load from peak to off-peak in a commercial building. Thermal energy storage can play a very important role in providing demand-side management for diversifying the utility demand from buildings. Model of a large commercial office building is developed with thermal storage for cooling for peak power shifting. Three variations of the model were developed and analyzed for their performance with 1) ice storage, 2) chilled water storage with mixed storage tank and 3) chilled water storage with stratified tank, using EnergyPlus 8.5 software developed by the US Department of Energy. Operation strategy with tactical control to incorporate peak power schedule was developed using energy management system (EMS). The modeled HVAC system was optimized for minimum cost with the optimal storage capacity and chiller size using JEPlus. Based on the simulation, an optimal storage capacity of 40-45 GJ was estimated for the large office building model along with 40% smaller chiller capacity resulting in higher chiller part-load performance. Additionally, the auxiliary system like pump and condenser were also optimized to smaller capacities and thus resulting in less power demand during operation. The overall annual saving potential was found in the range of 7-10% for cooling electricity use resulting in 10-17% reduction in costs to the consumer. A possible annual peak shifting of 25-78% was found from the simulation results after comparing with the reference models. Adopting TES in commercial buildings and achieving 25% peak shifting could result in a reduction in peak summer demand of 1398 MW in Tampa.
30. BUILDING NO.S 271K AND 271L, VIEW LOOKING SOUTH AT ...
30. BUILDING NO.S 271-K AND 271-L, VIEW LOOKING SOUTH AT BACK OF BUILDING NO. 271-L (LEFT), 271-K (MIDDLE) AND ROOF OF BUILDING NO. 271-I (VISIBLE OVER WALKWAY ON RIGHT). - Picatinny Arsenal, 200 Area, Shell Component Loading, State Route 15 near I-80, Dover, Morris County, NJ
Automated Measurement and Verification and Innovative Occupancy Detection Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, Phillip; Bruce, Nordman; Piette, Mary Ann
In support of DOE’s sensors and controls research, the goal of this project is to move toward integrated building to grid systems by building on previous work to develop and demonstrate a set of load characterization measurement and evaluation tools that are envisioned to be part of a suite of applications for transactive efficient buildings, built upon data-driven load characterization and prediction models. This will include the ability to include occupancy data in the models, plus data collection and archival methods to include different types of occupancy data with existing networks and a taxonomy for naming these data within amore » Volttron agent platform.« less
Behavior of tunnel form buildings under quasi-static cyclic lateral loading
Yuksel, S.B.; Kalkan, E.
2007-01-01
In this paper, experimental investigations on the inelastic seismic behavior of tunnel form buildings (i.e., box-type or panel systems) are presented. Two four-story scaled building specimens were tested under quasi-static cyclic lateral loading in longitudinal and transverse directions. The experimental results and supplemental finite element simulations collectively indicate that lightly reinforced structural walls of tunnel form buildings may exhibit brittle flexural failure under seismic action. The global tension/compression couple triggers this failure mechanism by creating pure axial tension in outermost shear-walls. This type of failure takes place due to rupturing of longitudinal reinforcement without crushing of concrete, therefore is of particular interest in emphasizing the mode of failure that is not routinely considered during seismic design of shear-wall dominant structural systems.
Optimal Coordination of Building Loads and Energy Storage for Power Grid and End User Services
Hao, He; Wu, Di; Lian, Jianming; ...
2017-01-18
Demand response and energy storage play a profound role in the smart grid. The focus of this study is to evaluate benefits of coordinating flexible loads and energy storage to provide power grid and end user services. We present a Generalized Battery Model (GBM) to describe the flexibility of building loads and energy storage. An optimization-based approach is proposed to characterize the parameters (power and energy limits) of the GBM for flexible building loads. We then develop optimal coordination algorithms to provide power grid and end user services such as energy arbitrage, frequency regulation, spinning reserve, as well as energymore » cost and demand charge reduction. Several case studies have been performed to demonstrate the efficacy of the GBM and coordination algorithms, and evaluate the benefits of using their flexibility for power grid and end user services. We show that optimal coordination yields significant cost savings and revenue. Moreover, the best option for power grid services is to provide energy arbitrage and frequency regulation. Finally and furthermore, when coordinating flexible loads with energy storage to provide end user services, it is recommended to consider demand charge in addition to time-of-use price in order to flatten the aggregate power profile.« less
Literature Review of the Effects of Natural Light on Building Occupants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, L.; Torcellini, P.
This paper presents summary findings from a literature search of the term ''daylighting''-using natural light in a building to offset or replace electric lighting. According to the Department of Energy's Office of Building Technology, State and Community Programs 2000 BTS Core Databook, in 1998, commercial buildings consumed 32% of the total electricity in the United States, of which more than one-third went to lighting. Using daylighting systems and turning off the lights will help reduce this energy load. Electrical lighting adds to both the electrical and cooling loads in a commercial building. Utility costs can be decreased when daylighting ismore » properly designed to replace electrical lighting. Along with the importance of energy savings, studies have demonstrated the non-energy-related benefits of daylighting. We compiled the data from books, periodicals, Internet articles, and interviews. The books, periodicals, and Internet articles provided the background information used to identify the main subjects of the paper. The interviews provided us with details related to specific buildings and companies that have integrated daylighting into their buildings.« less
Comparison of analytical methods for calculation of wind loads
NASA Technical Reports Server (NTRS)
Minderman, Donald J.; Schultz, Larry L.
1989-01-01
The following analysis is a comparison of analytical methods for calculation of wind load pressures. The analytical methods specified in ASCE Paper No. 3269, ANSI A58.1-1982, the Standard Building Code, and the Uniform Building Code were analyzed using various hurricane speeds to determine the differences in the calculated results. The winds used for the analysis ranged from 100 mph to 125 mph and applied inland from the shoreline of a large open body of water (i.e., an enormous lake or the ocean) a distance of 1500 feet or ten times the height of the building or structure considered. For a building or structure less than or equal to 250 feet in height acted upon by a wind greater than or equal to 115 mph, it was determined that the method specified in ANSI A58.1-1982 calculates a larger wind load pressure than the other methods. For a building or structure between 250 feet and 500 feet tall acted upon by a wind rangind from 100 mph to 110 mph, there is no clear choice of which method to use; for these cases, factors that must be considered are the steady-state or peak wind velocity, the geographic location, the distance from a large open body of water, and the expected design life and its risk factor.
Operating and Maintaining Energy Smart Schools Action Plan Template - All Action Plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2009-07-01
EnergySmart Schools action plan templates for benchmarking, lighting, HVAC, water heating, building envelope, transformer, plug loads, kitchen equipment, swimming pool, building automation system, other.
Successful NEES Grand Challenge Tests on Non-Ductile Beam-Column Joints
potential of existing gravity load designed RC buildings is a great concern during intense seismic events evaluate unreinforced corner joints shear strength and axial residual capacity under high axial load axial load is 0.20f Âc Ag , while the overturning axial loads vary with displacement reversals to range
Deformations of temporary wooden supports used to reduce building deflections in mining areas
NASA Astrophysics Data System (ADS)
Gromysz, Krzysztof
2018-04-01
Temporary supports, consisting of a stack of wooden elements and a hydraulic jack, are used in the process of removing deflections in buildings with one to three aboveground floors in mining areas. During uneven raising, the supports are loaded monotonically, unloaded and loaded cyclically. Laboratory tests were designed for the supports. For the investigated range of loads of 0 to 400 kN, under a growing load, a linear relationship exists between a load and the change in the stack length, which signifies that the deformations of wooden elements and displacements related to their mutual interactions increase proportionally. A seemingly higher stack stiffness is seen at the beginning of the unloading process and for cyclical loads, meaning that in this phase of loading, the material deformation of the wooden elements and the jack is responsible for changing the jack length in this load phase, with a negligible presence of mutual displacements of wooden elements. The support, after being unloaded, returns to the initial position and its permanent deformations are not observed. The stiffness of a temporary support decreases as the height of the stack of wooden elements increases.
Modeling of two-storey precast school building using Ruaumoko 2D program
NASA Astrophysics Data System (ADS)
Hamid, N. H.; Tarmizi, L. H.; Ghani, K. D.
2015-05-01
The long-distant earthquake loading from Sumatra and Java Island had caused some slight damages to precast and reinforced concrete buildings in West Malaysia such as cracks on wall panels, columns and beams. Subsequently, the safety of existing precast concrete building is needed to be analyzed because these buildings were designed using BS 8110 which did not include the seismic loading in the design. Thus, this paper emphasizes on the seismic performance and dynamic behavior of precast school building constructed in Malaysia under three selected past earthquakes excitations ; El Centro 1940 North-South, El Centro East-West components and San Fernando 1971 using RUAUMOKO 2D program. This program is fully utilized by using prototype precast school model and dynamic non-linear time history analysis. From the results, it can be concluded that two-storey precast school building has experienced severe damage and partial collapse especially at beam-column joint under San Fernando and El Centro North-South Earthquake as its exceeds the allowable inter-storey drift and displacement as specified in Eurocode 8. The San Fernando earthquake has produced a massive destruction to the precast building under viscous damping, ξ = 5% and this building has generated maximum building displacement of 435mm, maximum building drift of 0.68% and maximum bending moment at 8458kNm.
2007-02-01
on/off control), trending and trend reports, load shedding/load manage- ment, remote setpoint adjustment, initial diagnosis of a service call and...building-specific operational data such as on/off scheduling com- mands, setpoints , and outside air temperature. With help from several other agencies and...interface for monitoring 3. Provide one interface for device/system management/configuration 4. ( Optimally ) provide one interface for device
2007-02-01
on/off control), trending and trend reports, load shedding/load manage- ment, remote setpoint adjustment, initial diagnosis of a service call and...building-specific operational data such as on/off scheduling com- mands, setpoints , and outside air temperature. With help from several other agencies and...interface for monitoring 3. Provide one interface for device/system management/configuration 4. ( Optimally ) provide one interface for device
1981-03-01
AD-A B99 054 CONSTRUCTION EN INEERIN RESEARCH LAB (ARMY) CHAMPAIGN IL F/ 9/2 BUILDING LOADS ANALYSIS AND SYSTEM THERMOD NAMICS (BLAST) PROGR...continued. systems , (11) induction unit systems , (12) direct-drive chillers, and (13) purchased steam from utilities. BLAST Version 3.0 also offers the user...their BLAST input. II UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGEftin Date Rnerod) FOREWORD This report was prepared for the Air Force Systems
Smart Grid | Climate Neutral Research Campuses | NREL
begun to build smart grids. Most operate electricity grids that include power generation; load control plant managers use these communications for energy management and load shedding, which are among the top familiar with equipment interoperability, central dispatch, and load shedding. These are common in smart
Code of Federal Regulations, 2011 CFR
2011-01-01
... includes any non-heating season pilot input loss. Area of the space (A): the horizontal lighted area of a... doors of a building. Integrated part-load value (IPLV): a single-number figure of merit based on part-load EER or COP expressing part-load efficiency for air-conditioning and heat pump equipment on the...
Performance evaluation of existing building structure with pushover analysis
NASA Astrophysics Data System (ADS)
Handana, MAP; Karolina, R.; Steven
2018-02-01
In the management of the infrastructure of the building, during the period of buildings common building damage as a result of several reasons, earthquakes are common. The building is planned to work for a certain service life. But during the certain service life, the building vulnerable to damage due to various things. Any damage to cultivate can be detected as early as possible, because the damage could spread, triggering and exacerbating the latest. The newest concept to earthquake engineering is Performance Based Earthquake Engineering (PBEE). PBEE divided into two, namely Performance Based Seismic Design (PBSD) and Performance Based Seismic Evaluation (PBSE). Evaluation on PBSE one of which is the analysis of nonlinear pushover. Pushover analysis is a static analysis of nonlinear where the influence of the earthquake plan on building structure is considered as burdens static catch at the center of mass of each floor, which it was increased gradually until the loading causing the melting (plastic hinge) first within the building structure, then the load increases further changes the shapes of post-elastic large it reached the condition of elastic. Then followed melting (plastic hinge) in the location of the other structured.
8. DETAIL OF COVERED LOADING DOCK ON NORTH SIDE. VIEW ...
8. DETAIL OF COVERED LOADING DOCK ON NORTH SIDE. VIEW TO SOUTHWEST. - Commercial & Industrial Buildings, International Harvester Company Showroom, Office & Warehouse, 10 South Main Street, Dubuque, Dubuque County, IA
Building Quakes: Detection of Weld Fractures in Buildings using High-Frequency Seismic Techniques
NASA Astrophysics Data System (ADS)
Heckman, V.; Kohler, M. D.; Heaton, T. H.
2009-12-01
Catastrophic fracture of welded beam-column connections in buildings was observed in the Northridge and Kobe earthquakes. Despite the structural importance of such connections, it can be difficult to locate damage in structural members underneath superficial building features. We have developed a novel technique to locate fracturing welds in buildings in real time using high-frequency information from seismograms. Numerical and experimental methods were used to investigate an approach for detecting the brittle fracture of welds of beam-column connections in instrumented steel moment-frame buildings through the use of time-reversed Green’s functions and wave propagation reciprocity. The approach makes use of a prerecorded catalogue of Green’s functions for an instrumented building to detect high-frequency failure events in the building during a later earthquake by screening continuous data for the presence of one or more of the events. This was explored experimentally by comparing structural responses of a small-scale laboratory structure under a variety of loading conditions. Experimentation was conducted on a polyvinyl chloride frame model structure with data recorded at a sample rate of 2000 Hz using piezoelectric accelerometers and a 24-bit digitizer. Green’s functions were obtained by applying impulsive force loads at various locations along the structure with a rubber-tipped force transducer hammer. We performed a blind test using cross-correlation techniques to determine if it was possible to use the catalogue of Green’s functions to pinpoint the absolute times and locations of subsequent, induced failure events in the structure. A finite-element method was used to simulate the response of the model structure to various source mechanisms in order to determine the types of elastic waves that were produced as well as to obtain a general understanding of the structural response to localized loading and fracture.
NASA Astrophysics Data System (ADS)
Zhu, Na
This thesis presents an overview of the previous research work on dynamic characteristics and energy performance of buildings due to the integration of PCMs. The research work on dynamic characteristics and energy performance of buildings using PCMs both with and without air-conditioning is reviewed. Since the particular interest in using PCMs for free cooling and peak load shifting, specific research efforts on both subjects are reviewed separately. A simplified physical dynamic model of building structures integrated with SSPCM (shaped-stabilized phase change material) is developed and validated in this study. The simplified physical model represents the wall by 3 resistances and 2 capacitances and the PCM layer by 4 resistances and 2 capacitances respectively while the key issue is the parameter identification of the model. This thesis also presents the studies on the thermodynamic characteristics of buildings enhanced by PCM and on the investigation of the impacts of PCM on the building cooling load and peak cooling demand at different climates and seasons as well as the optimal operation and control strategies to reduce the energy consumption and energy cost by reducing the air-conditioning energy consumption and peak load. An office building floor with typical variable air volume (VAV) air-conditioning system is used and simulated as the reference building in the comparison study. The envelopes of the studied building are further enhanced by integrating the PCM layers. The building system is tested in two selected cities of typical climates in China including Hong Kong and Beijing. The cold charge and discharge processes, the operation and control strategies of night ventilation and the air temperature set-point reset strategy for minimizing the energy consumption and electricity cost are studied. This thesis presents the simulation test platform, the test results on the cold storage and discharge processes, the air-conditioning energy consumption and demand reduction potentials in typical air-conditioning seasons in typical China cites as well as the impacts of operation and control strategies.
11. SOUTH SIDE OF WAREHOUSE, WITH LOADING DOCK IN FOREGROUND. ...
11. SOUTH SIDE OF WAREHOUSE, WITH LOADING DOCK IN FOREGROUND. VIEW TO NORTHWEST. - Commercial & Industrial Buildings, International Harvester Company Showroom, Office & Warehouse, 10 South Main Street, Dubuque, Dubuque County, IA
3. Cement and Plaster Warehouse, north facade. Loading ramp on ...
3. Cement and Plaster Warehouse, north facade. Loading ramp on the right. Utility building, intrusion, on the far right. - Curtis Wharf, Cement & Plaster Warehouse, O & Second Streets, Anacortes, Skagit County, WA
20. VIEW OF WORTHINGTON BASE LOAD OXYGEN COMPRESSOR IN THE ...
20. VIEW OF WORTHINGTON BASE LOAD OXYGEN COMPRESSOR IN THE HIGH PURITY OXYGEN BUILDING LOOKING NORTH. - U.S. Steel Duquesne Works, Fuel & Utilities Plant, Along Monongahela River, Duquesne, Allegheny County, PA
Continuation Power Flow Analysis for PV Integration Studies at Distribution Feeders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jiyu; Zhu, Xiangqi; Lubkeman, David L.
2017-10-30
This paper presents a method for conducting continuation power flow simulation on high-solar penetration distribution feeders. A load disaggregation method is developed to disaggregate the daily feeder load profiles collected in substations down to each load node, where the electricity consumption of residential houses and commercial buildings are modeled using actual data collected from single family houses and commercial buildings. This allows the modeling of power flow and voltage profile along a distribution feeder on a continuing fashion for a 24- hour period at minute-by-minute resolution. By separating the feeder into load zones based on the distance between the loadmore » node and the feeder head, we studied the impact of PV penetration on distribution grid operation in different seasons and under different weather conditions for different PV placements.« less
Looking Southwest to Dry and Wet Exterior Scrubbers at Rear ...
Looking Southwest to Dry and Wet Exterior Scrubbers at Rear of Oxide Building - Hematite Fuel Fabrication Facility, Oxide Building & Oxide Loading Dock, 3300 State Road P, Festus, Jefferson County, MO
Looking West From rear (East) End of Office Building Including ...
Looking West From rear (East) End of Office Building Including Recycle Storage Area, Loading Docks, and Decontamination Zone - Hematite Fuel Fabrication Facility, Office, 3300 State Road P, Festus, Jefferson County, MO
Design New Buildings To Save Energy -- and Money
ERIC Educational Resources Information Center
Rittelmann, Richard
1974-01-01
Buildings should be designed so that energy systems function with maximum efficiency. Re-evaluation of standards for ventilation and lighting is recommended. Heat recovery techniques and topography can reduce heating loads. (MF)
NASA Astrophysics Data System (ADS)
Breen, M.; O'Donovan, A.; Murphy, M. D.; Delaney, F.; Hill, M.; Sullivan, P. D. O.
2016-03-01
The aim of this paper was to develop a virtual laboratory simulation platform of the National Building Retrofit Test-bed at the Cork Institute of Technology, Ireland. The building in question is a low-energy retrofit which is provided with electricity by renewable systems including photovoltaics and wind. It can be thought of as a living laboratory, as a number of internal and external building factors are recorded at regular intervals during human occupation. The analysis carried out in this paper demonstrated that, for the period from April to September 2015, the electricity provided by the renewable systems did not consistently match the building’s electricity requirements due to differing load profiles. It was concluded that the use of load shifting techniques may help to increase the percentage of renewable energy utilisation.
Seismic Behaviour of Masonry Vault-Slab Structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chesi, Claudio; Butti, Ferdinando; Ferrari, Marco
2008-07-08
Spandrel walls typically play a structural role in masonry buildings, transferring load from a slab to the supporting vault. Some indications are given in the literature on the behaviour of spandrels under the effect of vertical loads, but little attention is given to the effect coming from lateral forces acting on the building. An opportunity to investigate this problem has come from the need of analyzing a monumental building which was damaged by the Nov. 24, 2004 Val Sabbia earthquake in the north of Italy. The finite element model set up for the analysis of the vault-spandrel-slab system is presentedmore » and the structural role resulting for the spandrels is discussed.« less
NASA Technical Reports Server (NTRS)
Lansing, F. L.; Strain, D. M.; Chai, V. W.; Higgins, S.
1979-01-01
The energy Comsumption Computer Program was developed to simulate building heating and cooling loads and compute thermal and electric energy consumption and cost. This article reports on the new additional algorithms and modifications made in an effort to widen the areas of application. The program structure was rewritten accordingly to refine and advance the building model and to further reduce the processing time and cost. The program is noted for its very low cost and ease of use compared to other available codes. The accuracy of computations is not sacrificed however, since the results are expected to lie within + or - 10% of actual energy meter readings.
Energy consumption program: A computer model simulating energy loads in buildings
NASA Technical Reports Server (NTRS)
Stoller, F. W.; Lansing, F. L.; Chai, V. W.; Higgins, S.
1978-01-01
The JPL energy consumption computer program developed as a useful tool in the on-going building modification studies in the DSN energy conservation project is described. The program simulates building heating and cooling loads and computes thermal and electric energy consumption and cost. The accuracy of computations are not sacrificed, however, since the results lie within + or - 10 percent margin compared to those read from energy meters. The program is carefully structured to reduce both user's time and running cost by asking minimum information from the user and reducing many internal time-consuming computational loops. Many unique features were added to handle two-level electronics control rooms not found in any other program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. Aldrich and J. Williamson
Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2.) Because of better scale, SDHW systems in multifamily buildings cost significantly lessmore » per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support form the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aldrich, Robb; Williamson, James
Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: 1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads; 2) Because of better scale, SDHW systems in multifamily buildings cost significantly lessmore » per dwelling than in single-family homes; 3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating; and 4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2) Because of better scale, SDHW systems in multifamily buildings cost significantly lessmore » per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.« less
End-use energy consumption estimates for US commercial buildings, 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belzer, D.B.; Wrench, L.E.; Marsh, T.L.
An accurate picture of how energy is used in the nation`s stock of commercial buildings can serve a variety of program planning and policy needs within the Department of Energy, by utilities, and other groups seeking to improve the efficiency of energy use in the building sector. This report describes an estimation of energy consumption by end use based upon data from the 1989 Commercial Building Energy Consumption Survey (CBECS). The methodology used in the study combines elements of engineering simulations and statistical analysis to estimate end-use intensities for heating, cooling, ventilation, lighting, refrigeration, hot water, cooking, and miscellaneous equipment.more » Billing data for electricity and natural gas were first decomposed into weather and nonweather dependent loads. Subsequently, Statistical Adjusted Engineering (SAE) models were estimated by building type with annual data. The SAE models used variables such as building size, vintage, climate region, weekly operating hours, and employee density to adjust the engineering model predicted loads to the observed consumption. End-use consumption by fuel was estimated for each of the 5,876 buildings in the 1989 CBECS. The report displays the summary results for eleven separate building types as well as for the total US commercial building stock.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Zhiyang; Zhang, Xiong
A dynamic computer simulation is carried out in the climates of 35 cities distributed around the world. The variation of the annual air-conditioning energy loads due to changes in the longwave emissivity and the solar reflectance of the building envelopes is studied to find the most appropriate exterior building finishes in various climates (including a tropical climate, a subtropical climate, a mountain plateau climate, a frigid-temperate climate and a temperate climate). Both the longwave emissivity and the solar reflectance are set from 0.1 to 0.9 with an interval of 0.1 in the simulation. The annual air-conditioning energy loads trends ofmore » each city are listed in a chart. The results show that both the longwave emissivity and the solar reflectance of building envelopes play significant roles in energy-saving for buildings. In tropical climates, the optical parameters of the building exterior surface affect the building energy-saving most significantly. In the mountain plateau climates and the subarctic climates, the impacts on energy-saving in buildings due to changes in the longwave emissivity and the solar reflectance are still considerable, but in the temperate continental climates and the temperate maritime climates, only limited effects are seen. (author)« less
Building Energy Modeling and Control Methods for Optimization and Renewables Integration
NASA Astrophysics Data System (ADS)
Burger, Eric M.
This dissertation presents techniques for the numerical modeling and control of building systems, with an emphasis on thermostatically controlled loads. The primary objective of this work is to address technical challenges related to the management of energy use in commercial and residential buildings. This work is motivated by the need to enhance the performance of building systems and by the potential for aggregated loads to perform load following and regulation ancillary services, thereby enabling the further adoption of intermittent renewable energy generation technologies. To increase the generalizability of the techniques, an emphasis is placed on recursive and adaptive methods which minimize the need for customization to specific buildings and applications. The techniques presented in this dissertation can be divided into two general categories: modeling and control. Modeling techniques encompass the processing of data streams from sensors and the training of numerical models. These models enable us to predict the energy use of a building and of sub-systems, such as a heating, ventilation, and air conditioning (HVAC) unit. Specifically, we first present an ensemble learning method for the short-term forecasting of total electricity demand in buildings. As the deployment of intermittent renewable energy resources continues to rise, the generation of accurate building-level electricity demand forecasts will be valuable to both grid operators and building energy management systems. Second, we present a recursive parameter estimation technique for identifying a thermostatically controlled load (TCL) model that is non-linear in the parameters. For TCLs to perform demand response services in real-time markets, online methods for parameter estimation are needed. Third, we develop a piecewise linear thermal model of a residential building and train the model using data collected from a custom-built thermostat. This model is capable of approximating unmodeled dynamics within a building by learning from sensor data. Control techniques encompass the application of optimal control theory, model predictive control, and convex distributed optimization to TCLs. First, we present the alternative control trajectory (ACT) representation, a novel method for the approximate optimization of non-convex discrete systems. This approach enables the optimal control of a population of non-convex agents using distributed convex optimization techniques. Second, we present a distributed convex optimization algorithm for the control of a TCL population. Experimental results demonstrate the application of this algorithm to the problem of renewable energy generation following. This dissertation contributes to the development of intelligent energy management systems for buildings by presenting a suite of novel and adaptable modeling and control techniques. Applications focus on optimizing the performance of building operations and on facilitating the integration of renewable energy resources.
PS3-21: Extracting Utilization Data from Clarity into VDW Using Oracle and SAS
Chimmula, Srivardhan
2013-01-01
Background/Aims The purpose of the presentation is to demonstrate how we use SAS and Oracle to load VDW_Utilization, VDW_DX, and VDW_PX tables from Clarity at the Kaiser Permanente Northern California (KPNC) Division of Research (DOR) site. Methods DOR uses the best of Oracle PL/ SQL and SAS capabilities in building Extract Transform and Load (ETL) processes. These processes extract patient encounter, diagnosis, and procedure data from Teradata-based Clarity. The data is then transformed to fit HMORN’s VDW definitions of the table. This data is then loaded into the Oracle-based VDW table on DOR’s research database and then finally a copy of the table is also created as a SAS dataset. Results DOR builds robust and efficient ETL processes that refresh VDW Utilization table on a monthly basis processing millions of records/observations. The ETL processes have the capability to identify daily changes in Clarity and update the VDW tables on a daily basis. Conclusions KPNC DOR combines the best of both Oracle and SAS worlds to build ETL processes that load the data into VDW Utilization tables efficiently.
Numerical Modelling of Connections Between Stones in Foundations of Historical Buildings
NASA Astrophysics Data System (ADS)
Przewlocki, Jaroslaw; Zielinska, Monika; Grebowski, Karol
2017-12-01
The aim of this paper is to analyse the behaviour of old building foundations composed of stones (the main load-bearing elements) and mortar, based on numerical analysis. Some basic aspects of historical foundations are briefly discussed, with an emphasis on their development, techniques, and material. The behaviour of a foundation subjected to the loads transmitted from the upper parts of the structure is described using the finite element method (FEM). The main problems in analysing the foundations of historical buildings are determining the characteristics of the materials and the degree of degradation of the mortar, which is the weakest part of the foundation. Mortar is graded using the damaged-plastic model. In this model, exceeding the bearing capacity occurs due to the degradation of materials. The damaged-plastic model is the most accurate model describing the work and properties of mortar because it shows exactly what happens with this material throughout its total load history. For a uniformly loaded fragment of the foundation, both stresses and strains were analysed. The results of the analysis presented in this paper contribute to further research in the field of understanding both behaviour and modelling in historical buildings’ foundations.
Center for the Built Environment: UFAD Cooling Load Design Tool
Energy Publications Project Title: Underfloor Air Distribution (UFAD) Cooling Load Design Tool Providing . Webster, 2010. Development of a simplified cooling load design tool for underfloor air distribution Near-ZNE Buildings Setpoint Energy Savings Calculator UFAD Case Studies UFAD Cooling Design Tool UFAD
Geothermal-retrofit study for the National Orange Show Facilities in San Bernardino, California
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-11-17
The cost and feasibility of retrofitting the National Orange Show Facilities to use geothermal heat instead of natural gas for heating are determined. Because of the limited usage of the smaller facilities the study was limited to the conversion of the six major buildings: Domed, Hobby, Citrus, Auditorium, Restaurant and Commercial. A major problem is that most of the buildings are used on a very limited basis. This drastically reduced the amount of savings that could be used to amortize the retrofit cost. Another problem is that the buildings are spread over a large area and so the below grademore » piping costs were high. Finally, all of the buildings except for the Auditorium have direct gas fired heaters that would require all new terminal heating systems. In order to limit the retrofit cost, the retrofit system was designed to handle less than the peak load. This seemed appropriate because the facility might not even be in operation when a peak load condition occurred. Also, the existing systems could be used to supplement the geothermal system if necessary. The calculated and design peak loads are summarized.« less
Hong, Nian; Zhu, Panfeng; Liu, An
2017-12-01
Urban road stormwater is an alternative water resource to mitigate water shortage issues in the worldwide. Heavy metals deposited (build-up) on urban road surface can enter road stormwater runoff, undermining stormwater reuse safety. As heavy metal build-up loads perform high variabilities in terms of spatial distribution and is strongly influenced by surrounding land uses, it is essential to develop an approach to identify hot-spots where stormwater runoff could include high heavy metal concentrations and hence cannot be reused if it is not properly treated. This study developed a robust modelling approach to estimating heavy metal build-up loads on urban roads using land use fractions (representing percentages of land uses within a given area) by an artificial neural network (ANN) model technique. Based on the modelling results, a series of heavy metal load spatial distribution maps and a comprehensive ecological risk map were generated. These maps provided a visualization platform to identify priority areas where the stormwater can be safely reused. Additionally, these maps can be utilized as an urban land use planning tool in the context of effective stormwater reuse strategy implementation. Copyright © 2017 Elsevier Ltd. All rights reserved.
4. DETAIL OF NORTH SIDE OF OFFICE/SHOWROOM, SHOWING COVERED LOADING ...
4. DETAIL OF NORTH SIDE OF OFFICE/SHOWROOM, SHOWING COVERED LOADING DOCK. VIEW TO SOUTH. - Commercial & Industrial Buildings, International Harvester Company Showroom, Office & Warehouse, 10 South Main Street, Dubuque, Dubuque County, IA
12. VIEW OF CANOPY OVER NORTHWEST LOADING PLATFORM, RUNNING NEARLY ...
12. VIEW OF CANOPY OVER NORTHWEST LOADING PLATFORM, RUNNING NEARLY THE ENTIRE LENGTH OF THE BUILDING - Oakland Army Base, Transit Shed, East of Dunkirk Street & South of Burma Road, Oakland, Alameda County, CA
36. ASSEMBLY LINE AREA FROM NEAR INTERIOR LOADING DOCK. VIEW ...
36. ASSEMBLY LINE AREA FROM NEAR INTERIOR LOADING DOCK. VIEW TO WEST-NORTHWEST. - Ford Motor Company Long Beach Assembly Plant, Assembly Building, 700 Henry Ford Avenue, Long Beach, Los Angeles County, CA
10 CFR 434.518 - Service water heating.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Service water heating. 434.518 Section 434.518 Energy... RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.518 Service water heating. 518.1The service water loads for Prototype and Reference Buildings are defined in terms of Btu/h per person in...
10 CFR 434.518 - Service water heating.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Service water heating. 434.518 Section 434.518 Energy... RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.518 Service water heating. 518.1 The service water loads for Prototype and Reference Buildings are defined in terms of Btu/h per person in...
10 CFR 434.518 - Service water heating.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Service water heating. 434.518 Section 434.518 Energy... RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.518 Service water heating. 518.1The service water loads for Prototype and Reference Buildings are defined in terms of Btu/h per person in...
Simulated building energy demand biases resulting from the use of representative weather stations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burleyson, Casey D.; Voisin, Nathalie; Taylor, Z. Todd
Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. We quantify the potential reduction in bias from using an increasing number of weather stations over the western U.S. The approach is based on deriving temperature and load time series using incrementally more weather stations, ranging from 8 to roughly 150, tomore » capture weather across different seasons. Using 8 stations, one from each climate zone, across the western U.S. results in an average absolute summertime temperature bias of 7.2°F with respect to a spatially-resolved gridded dataset. The mean absolute bias drops to 2.8°F using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.8%, a significant error for capacity expansion planners who may use these types of simulations. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Using 8 representative weather stations can lead to a 20-40% overestimation of peak building loads during both summer and winter. Using weather stations close to population centers reduces both mean and peak load biases. This approach could be used by others designing aggregate building simulations to understand the sensitivity to their choice of weather stations used to drive the models.« less
1. General oblique view of north and east sides, view ...
1. General oblique view of north and east sides, view to southwest, showing main loading docks - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX
Looking North at Reactor Number One and Air Vent on ...
Looking North at Reactor Number One and Air Vent on Fourth Floor of Oxide Building - Hematite Fuel Fabrication Facility, Oxide Building & Oxide Loading Dock, 3300 State Road P, Festus, Jefferson County, MO
Design and implementation of an air-conditioning system with storage tank for load shifting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, Y.Y.; Wu, C.J.; Liou, K.L.
1987-11-01
The experience with the design, simulation and implementation of an air-conditioning system with chilled water storage tank is presented in this paper. The system is used to shift air-conditioning load of residential and commercial buildings from on-peak to off-peak period. Demand-side load management can thus be achieved if many buildings are equipped with such storage devices. In the design of this system, a lumped-parameter circuit model is first employed to simulate the heat transfer within the air-conditioned building such that the required capacity of the storage tank can be figured out. Then, a set of desirable parameters for the temperaturemore » controller of the system are determined using the parameter plane method and the root locus method. The validity of the proposed mathematical model and design approach is verified by comparing the results obtained from field tests with those from the computer simulations. Cost-benefit analysis of the system is also discussed.« less
Commercial equipment loads: End-Use Load and Consumer Assessment Program (ELCAP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pratt, R.G.; Williamson, M.A.; Richman, E.E.
1990-07-01
The Office of Energy Resources of the Bonneville Power Administration is generally responsible for the agency's power and conservation resource planning. As associated responsibility which supports a variety of office functions is the analysis of historical trends in and determinants of energy consumption. The Office of Energy Resources' End-Use Research Section operates a comprehensive data collection program to provide pertinent information to support demand-side planning, load forecasting, and demand-side program development and delivery. Part of this on-going program is known as the End-Use Load and Consumer Assessment Program (ELCAP), an effort designed to collect electricity usage data through direct monitoringmore » of end-use loads in buildings. This program is conducted for Bonneville by the Pacific Northwest Laboratory. This report provides detailed information on electricity consumption of miscellaneous equipment from the commercial portion of ELCAP. Miscellaneous equipment includes all commercial end-uses except heating, ventilating, air conditioning, and central lighting systems. Some examples of end-uses covered in this report are office equipment, computers, task lighting, refrigeration, and food preparation. Electricity consumption estimates, in kilowatt-hours per square food per year, are provided for each end-use by building type. The following types of buildings are covered: office, retail, restaurant, grocery, warehouse, school, university, and hotel/motel. 6 refs., 35 figs., 12 tabs.« less
Gowda, Srinivasa; Quadras, Dilip D; Sesappa, Shetty R; Maiya, G R Ramakrishna; Kumar, Lalit; Kulkarni, Dinraj; Mishra, Nitu
2018-05-01
The aim of the study was to evaluate the fracture strength of three types of composite core build-up materials. The objectives were to study and evaluate the fracture strength and type of fracture in composite core build-up in restoration of endodonti-cally treated teeth with or without a prefabricated metallic post. A total of 60 freshly extracted mandibular premolars free of caries, cracks, or fractures were end-odontically treated and restored with composite core build-up with prefabricated metallic posts cemented with resin luting cement (group I) and without a post (group II). This was followed by a core build-up of 10 teeth each with three different types of composite materials: Hybrid composite, nanocomposite, and ormocer respectively. The samples were mounted on polyvinyl chloride block and then loaded in the universal load frame at 90° to the long axis of tooth. The fracture strength of the samples was directly obtained from the load indicator attached to the universal load frame. Analysis of variance (ANOVA) test revealed that teeth restored with post exhibited highest fracture strength (1552.32 N) and teeth restored without post exhibited lowest fracture strength (232.20 N). Bonferroni's test revealed that values for hybrid composite (Z-100, 3M ESPE) with post, nanocomposite (Z-350, 3M ESPE) with post, ormocer composite (Admira-VOCO) with post, and nanocomposite (Z-350, 3M ESPE) without post were not significantly different from each other. Teeth restored with post and core using hybrid composite yielded the highest values for fracture strength. Teeth restored with ormocer core without post exhibited the lowest values. Teeth restored with nanocomposite core without post exhibited strength that was comparable with hybrid composite core but higher than that of ormocer. Mutilated endodontically treated teeth can be prosthetically rehabilitated successfully by using adhesive composite core build-up along with post to meet anatomical, functional, and esthetic demands.
On the design of high-rise buildings with a specified level of reliability
NASA Astrophysics Data System (ADS)
Dolganov, Andrey; Kagan, Pavel
2018-03-01
High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.
Modeling of two-storey precast school building using Ruaumoko 2D program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamid, N. H.; Tarmizi, L. H.; Ghani, K. D.
The long-distant earthquake loading from Sumatra and Java Island had caused some slight damages to precast and reinforced concrete buildings in West Malaysia such as cracks on wall panels, columns and beams. Subsequently, the safety of existing precast concrete building is needed to be analyzed because these buildings were designed using BS 8110 which did not include the seismic loading in the design. Thus, this paper emphasizes on the seismic performance and dynamic behavior of precast school building constructed in Malaysia under three selected past earthquakes excitations ; El Centro 1940 North-South, El Centro East-West components and San Fernando 1971more » using RUAUMOKO 2D program. This program is fully utilized by using prototype precast school model and dynamic non-linear time history analysis. From the results, it can be concluded that two-storey precast school building has experienced severe damage and partial collapse especially at beam-column joint under San Fernando and El Centro North-South Earthquake as its exceeds the allowable inter-storey drift and displacement as specified in Eurocode 8. The San Fernando earthquake has produced a massive destruction to the precast building under viscous damping, ξ = 5% and this building has generated maximum building displacement of 435mm, maximum building drift of 0.68% and maximum bending moment at 8458kNm.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munk, Jeffrey D; Odukomaiya, Adewale O; Gehl, Anthony C
2014-01-01
With the recent advancements in the application of variable-speed (VS) compressors to residential HVAC systems, opportunities are now available to size heat pumps (HPs) to more effectively meet heating and cooling loads in many of the climate zones in the US with limited use of inefficient resistance heat. This is in contrast to sizing guidance for traditional single-speed HPs that limits the ability to oversize with regard to cooling loads, because of risks of poor dehumidification during the cooling season and increased cycling losses. VS-drive HPs can often run at 30-40% of their rated cooling capacity to reduce cycling losses,more » and can adjust fan speed to provide better indoor humidity control. Detailed air-side performance data was collected on two VS-drive heat pumps installed in a single unoccupied research house in Knoxville, TN, a mixed-humid climate. One system provided space conditioning for the upstairs, while the other unit provided space conditioning for the downstairs. Occupancy was simulated by operating the lights, shower, appliances, other plug loads, etc. to simulate the sensible and latent loads imposed on the building space by internal electric loads and human occupants according to the Building America Research Benchmark (2008). The seasonal efficiency and energy use of the units are calculated. Annual energy use is compared to that of the single speed minimum efficiency HPs tested in the same house previously. Sizing of the units relative to the measured building load and manual J design load calculations is examined. The impact of the unit sizing with regards to indoor comfort is also evaluated.« less
Low-Flow Liquid Desiccant Air-Conditioning: Demonstrated Performance and Cost Implications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozubal, E.; Herrmann, L.; Deru, M.
2014-09-01
Cooling loads must be dramatically reduced when designing net-zero energy buildings or other highly efficient facilities. Advances in this area have focused primarily on reducing a building's sensible cooling loads by improving the envelope, integrating properly sized daylighting systems, adding exterior solar shading devices, and reducing internal heat gains. As sensible loads decrease, however, latent loads remain relatively constant, and thus become a greater fraction of the overall cooling requirement in highly efficient building designs, particularly in humid climates. This shift toward latent cooling is a challenge for heating, ventilation, and air-conditioning (HVAC) systems. Traditional systems typically dehumidify by firstmore » overcooling air below the dew-point temperature and then reheating it to an appropriate supply temperature, which requires an excessive amount of energy. Another dehumidification strategy incorporates solid desiccant rotors that remove water from air more efficiently; however, these systems are large and increase fan energy consumption due to the increased airside pressure drop of solid desiccant rotors. A third dehumidification strategy involves high flow liquid desiccant systems. These systems require a high maintenance separator to protect the air distribution system from corrosive desiccant droplet carryover and so are more commonly used in industrial applications and rarely in commercial buildings. Both solid desiccant systems and most high-flow liquid desiccant systems (if not internally cooled) add sensible energy which must later be removed to the air stream during dehumidification, through the release of sensible heat during the sorption process.« less
After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.
2004-01-22
This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers.more » This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.« less
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2013 CFR
2013-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2011 CFR
2011-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2014 CFR
2014-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2012 CFR
2012-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2010 CFR
2010-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
Malfunction Investigation of the XM935 Point Detonating Fuze
1977-04-01
1 PSK* UNCHANGED FUMLY AR! 2 PSM UNCHANGED FULLY ARMED 3 OK PS4 UNCHANGD 4 CK P24 UNC DNGED 5 PSK (more than S.Q. Det Edge Visible FuLLY AP1M other...Continued) F= NO. DRC NO. 1 2 3 4 5 6 7 8 9 10 3 PSK UNCH UNCH UNCE SEE SQ UNCH UNCH UNCH UNCH UN1H 4 PS4 UNCH SKH E SQ UNCH tNCH UNCH UNCH U2 L!CH...EDGE 5 PS UNCH tCH SE SQ UNCH MMH UNCH UNCH UWCH WECH 6 P4M UNCH UNCH Q SEE SQ EDGE 7 PSK UNCH UNCH SEE SO WXC EDGE a P UNCP L4 UNCH SC E SQ 9 PS4 UNCX
1982-02-01
6.040 0.90 U 1-98 0 62120A FUZE/NUCLEAR WPNS EFFECTS /FLUIDICS 3 G.763 0.223 8,532 11.363 U [-105 O 62201A AIRCRAFT WEAPONS TE1CHNOLOGY 3 1,060 2.004...HUMAN FACTORS ENOR IN SYS DEV I 7.005 0.547 9.173 11.400 U 1-2)6 27 62717A HMRIAN PERFORMANCE EFFECT .’SIMJULATION I 3.196 3,373 3,581 4.360 U j-241 26...62710A MOBILITY AND WEAPONS EFFECTS TECH I5.251 6,260 6.410 9.402 U -245 29 62720A ENVIRONPOENTAL DUALITY TECH 6,437 7,493 6.706 9,627 u 1-251 30 02722A
Analysis of a digital RF memory in a signal-delay application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jelinek, D.A.
1992-03-01
Laboratory simulation of the approach of a radar fuze towards a target is an important factor in our ability to accurately measure the radar's performance. This simulation is achieved, in part, by dynamically delaying and attenuating the radar's transmitted pulse and sending the result back to the radar's receiver. Historically, the device used to perform the dynamic delay has been a limiting factor in the evaluation of a radar's performance and characteristics. A new device has been proposed that appears to have more capability than previous dynamic delay devices. This device is the digital RF memory. This report presents themore » results of an analysis of a digital RF memory used in a signal-delay application. 2 refs.« less
Symposium on Explosives and Pyrotechnics, 13th, Hilton Head Island, SC, Dec. 2-4, 1986, Proceedings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1987-01-01
The present conference on explosive and pyrotechnic technologies discusses the shock-sensitivity of RDX, the thermodynamic properties of RDX, TNT, nitroglycerine, and HMX energetic molecules, the dynamic resistivity of exploding conductors, the decomposition of azides, the critical shock-initiation energy of emulsion explosives, actuator valve optimization, pyrotechnic aerosolization from novel imbibed liquid matrices, tetrazole initiators, and polymeric binders for red phosphorus pellets. Also discussed are channel-effect studies, the dynamic desensitization of coal mine explosives, the electromagnetic and electrostatic protection of explosives, the reliability of fuze explosive trains, the hazardous properties of explosive chemicals, the emulsification of an explosive with a chemical foamingmore » agent, and low energy ignition of HMX using a foil bridge.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mazloom, M.
2008-07-08
The idea of safe room has been developed for decreasing the earthquake casualties in masonry buildings. The information obtained from the previous ground motions occurring in seismic zones expresses the lack of enough safety of these buildings against earthquakes. For this reason, an attempt has been made to create some safe areas inside the existing masonry buildings, which are called safe rooms. The practical method for making these safe areas is to install some prefabricated steel frames in some parts of the existing structure. These frames do not carry any service loads before an earthquake. However, if a devastating earthquakemore » happens and the load bearing walls of the building are destroyed, some parts of the floors, which are in the safe areas, will fall on the roof of the installed frames and the occupants who have sheltered there will survive. This paper presents the performance of these frames located in a destroying three storey masonry building with favorable conclusions. In fact, the experimental pushover diagram of the safe room located at the ground-floor level of this building is compared with the analytical results and it is concluded that pushover analysis is a good method for seismic performance evaluation of safe rooms. For time history analysis the 1940 El Centro, the 2003 Bam, and the 1990 Manjil earthquake records with the maximum peak accelerations of 0.35g were utilized. Also the design spectrum of Iranian Standard No. 2800-05 for the ground kind 2 is used for response spectrum analysis. The results of time history, response spectrum and pushover analyses show that the strength and displacement capacity of the steel frames are adequate to accommodate the distortions generated by seismic loads and aftershocks properly.« less
2D and 3D GPR imaging of structural ceilings in historic and existing constructions
NASA Astrophysics Data System (ADS)
Colla, Camilla
2014-05-01
GPR applications in civil engineering are to date quite diversified. With respect to civil constructions and monumental buildings, detection of voids, cavities, layering in structural elements, variation of geometry, of moisture content, of materials, areas of decay, defects, cracks have been reported in timber, concrete and masonry elements. Nonetheless, many more fields of investigation remain unexplored. This contribution gives an account of a variety of examples of structural ceilings investigation by GPR radar in reflection mode, either as 2D or 3D data acquisition and visualisation. Ceilings have a pre-eminent role in buildings as they contribute to a good structural behaviour of the construction. Primarily, the following functions can be listed for ceilings: a) they carry vertical dead and live loads on floors and distribute such loads to the vertical walls; b) they oppose to external horizontal forces such as wind loads and earthquakes helping to transfer such forces from the loaded element to the other walls; c) they contribute to create the box skeleton and behaviour of a building, connecting the different load bearing walls and reducing the slenderness and flexural instability of such walls. Therefore, knowing how ceilings are made in specific buildings is of paramount importance for architects and structural engineers. According to the type of building and age of construction, ceilings may present very different solutions and materials. Moreover, in existing constructions, ceilings may have been substituted, modified or strengthened due to material decay or to change of use of the building. These alterations may often go unrecorded in technical documentation or technical drawings may be unavailable. In many cases, the position, orientation and number of the load carrying elements in ceilings may be hidden or not be in sight, due for example to the presence of false ceilings or to technical plants. GPR radar can constitute a very useful tool for investigating with rapidity and high resolution, thin as well as very thick ceilings, in a non-destructive manner. Ceilings may be made up as masonry vaults or timber/metal/concrete beams and elements laid down in one or two directions or, again, can be made as a combination of the above. A number of cases are here presented reporting on typical features to be recognised in radargrams in order to distinguish the material and possible shape of the relevant objects with the aim of providing a first small catalogue useful to the radar user and to professionals. This abstract is of interest for COST Action TU1208.
Cost/Value Approach to Insulation Produces Savings at Sibley School
ERIC Educational Resources Information Center
School Business Affairs, 1978
1978-01-01
An energy savings study revealed that adding insulation to an existing building and reducing ventilation loads would enable the school to heat both the existing building and the addition with existing boiler equipment. (Author/MLF)
NASA Astrophysics Data System (ADS)
Mukherjee, Sananda
In recent years, there has been great interest in the potential of green roofs as an alternative roofing option to reduce the energy consumed by individual buildings as well as mitigate large scale urban environmental problems such as the heat island effect. There is a widespread recognition and a growing literature of measured data that suggest green roofs can reduce building energy consumption. This thesis investigates the potential of green roofs in reducing the building energy loads and focuses on how the different parameters of a green roof assembly affect the thermal performance of a building. A green roof assembly is modeled in Design Builder- a 3D graphical design modeling and energy use simulation program (interface) that uses the EnergyPlus simulation engine, and the simulated data set thus obtained is compared to field experiment data to validate the roof assembly model on the basis of how accurately it simulates the behavior of a green roof. Then the software is used to evaluate the thermal performance of several green roof assemblies under three different climate types, looking at the whole building energy consumption. For the purpose of this parametric simulation study, a prototypical single story small office building is considered and one parameter of the green roof is altered for each simulation run in order to understand its effect on building's energy loads. These parameters include different insulation thicknesses, leaf area indices (LAI) and growing medium or soil depth, each of which are tested under the three different climate types. The energy use intensities (EUIs), the peak and annual heating and cooling loads resulting from the use of these green roof assemblies are compared with each other and to a cool roof base case to determine the energy load reductions, if any. The heat flux through the roof is also evaluated and compared. The simulation results are then organized and finally presented as a decision support tool that would facilitate the adoption and appropriate utilization of green roof technologies and make it possible to account for green roof benefits in energy codes and related energy efficiency standards and rating systems such as LEED.
NASA Astrophysics Data System (ADS)
Patton, S. L.; Takle, E. S.; Passe, U.; Kalvelage, K.
2013-12-01
Current simulations of building energy consumption use weather input files based on the past thirty years of climate observations. These 20th century climate conditions may be inadequate when designing buildings meant to function well into the 21st century. An alternative is using model projections of climate change to estimate future risk to the built environment. In this study, model-projected changes in climate were combined with existing typical meteorological year data to create future typical meteorological year data. These data were then formatted for use in EnergyPlus simulation software to evaluate their potential impact on commercial building energy consumption. The modeled climate data were taken from the North American Regional Climate Change Assessment Program (NARCCAP). NARCCAP uses results of global climate models to drive regional climate models, also known as dynamical downscaling. This downscaling gives higher resolution results over specific locations, and the multiple global/regional climate model combinations provide a unique opportunity to quantify the uncertainty of climate change projections and their impacts. Our results show a projected decrease in heating energy consumption and a projected increase in cooling energy consumption for nine locations across the United States for all model combinations. Warmer locations may expect a decrease in heating load of around 30% to 45% and an increase in cooling load of around 25% to 35%. Colder locations may expect a decrease in heating load of around 15% to 25% and an increase in cooling load of around 40% to 70%. The change in net energy consumption is determined by the balance between the magnitudes of heating change and cooling change. Net energy consumption is projected to increase by an average of 5% for lower-latitude locations and decrease by an average of 5% for higher-latitude locations. With these projected annual and seasonal changes presenting strong evidence for the unsuitable nature of current building practices holding up under future climate change, we recommend using our methods and results to make modifications and adaptations to existing buildings and to aid in the design of future buildings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kung, Feitau; Frank, Stephen; Scheib, Jennifer
A zero energy building (ZEB)—also known as a net zero energy or zero net energy building—is a building that exports as much renewable energy as the total energy it imports from other sources on an annual basis (DOE 2015). Large-scale and commercially viable ZEBs are now in the marketplace, and they are expected to become a larger share of the commercial building footprint as government and private sector policies continue to promote the development of buildings that produce more on-site energy than they use. However, the load profiles of ZEBs are currently perceived by electric utilities to be unfavorable andmore » unpredictable. As shown in Figure ES-1, ZEB load profiles can have abrupt changes in magnitude, at times switching rapidly between exporting and importing electricity. This is a challenge for utilities, which are responsible for constantly balancing electricity supply and demand across the grid. Addressing these concerns will require new strategies and tools.« less
The use of nanomodified concrete in construction of high-rise buildings
NASA Astrophysics Data System (ADS)
Prokhorov, Sergei
2018-03-01
Construction is one of the leading economy sectors. Currently, concrete is the basis of most of the structural elements, without which it is impossible to imagine the construction of a single building or facility. Their strength, reinforcement and the period of concrete lifetime are determined at the design stage, taking into account long-term operation. However, in real life, the number of impacts that affects the structural strength is pretty high. In some cases, they are random and do not have standardized values. This is especially true in the construction and exploitation of high-rise buildings and structures. Unlike the multi-storey buildings, they experience significant loads already at the stage of erection, as they support load-lifting mechanisms, formwork systems, workers, etc. The purpose of the presented article is to develop a methodology for estimating the internal fatigue of concrete structures based on changes in their electrical conductivity.
Human Health Science Building Geothermal Heat Pump Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leidel, James
2014-12-22
The grant objectives of the DOE grant funded project have been successfully completed. The Human Health Building (HHB) was constructed and opened for occupancy for the Fall 2012 semester of Oakland University. As with any large construction project, some issues arose which all were overcome to deliver the project on budget and on time. The facility design is a geothermal / solar-thermal hybrid building utilizing both desiccant dehumidification and variable refrigerant flow heat pumps. It is a cooling dominant building with a 400 ton cooling design day load, and 150 ton heating load on a design day. A 256 verticalmore » borehole (320 ft depth) ground source heat pump array is located south of the building under the existing parking lot. The temperature swing and performance over 2013 through 2015 shows the ground loop is well sized, and may even have excess capacity for a future building to the north (planned lab facility). The HHB achieve a US Green Building Counsel LEED Platinum rating by collecting 52 of the total 69 available LEED points for the New Construction v.2 scoring checklist. Being Oakland's first geothermal project, we were very pleased with the building outcome and performance with the energy consumption approximately 1/2 of the campus average facility, on a square foot basis.« less
Bed load transport in gravel-bed rivers
Jeffrey J. Barry
2007-01-01
Bed load transport is a fundamental physical process in alluvial rivers, building and maintaining a channel geometry that reflects both the quantity and timing of water and the volume and caliber of sediment delivered from the watershed. A variety of formulae have been developed to predict bed load transport in gravel-bed rivers, but testing of the equations in natural...
ERIC Educational Resources Information Center
Hsiao, Ya-Ping; Brouns, Francis; van Bruggen, Jan; Sloep, Peter B.
2012-01-01
In Learning Networks, learners need to share knowledge with others to build knowledge. In particular, when working on complex tasks, they often need to acquire extra cognitive resources from others to process a high task load. However, without support high task load and organizing knowledge sharing themselves might easily overload learners'…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Woohyun; Katipamula, Srinivas; Lutes, Robert G.
This report describes how the intelligent load control (ILC) algorithm can be implemented to achieve peak demand reduction while minimizing impacts on occupant comfort. The algorithm was designed to minimize the additional sensors and minimum configuration requirements to enable a scalable and cost-effective implementation for both large and small-/medium-sized commercial buildings. The ILC algorithm uses an analytic hierarchy process (AHP) to dynamically prioritize the available curtailable loads based on both quantitative (deviation of zone conditions from set point) and qualitative rules (types of zone). Although the ILC algorithm described in this report was highly tailored to work with rooftop units,more » it can be generalized for application to other building loads such as variable-air-volume (VAV) boxes and lighting systems.« less
Solar Heating and Cooling of Buildings (Phase O). Volume 1: Executive Summary.
ERIC Educational Resources Information Center
TRW Systems Group, Redondo Beach, CA.
The purpose of this study was to establish the technical and economic feasibility of using solar energy for the heating and cooling of buildings. Five selected building types in 14 selected cities were used to determine loads for space heating, space cooling and dehumidification, and domestic service hot water heating. Relying on existing and…
User News. Volume 17, Number 1 -- Spring 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This is a newsletter for users of the DOE-2, PowerDOE, SPARK, and BLAST building energy simulation programs. The topics for the Spring 1996 issue include the SPARK simulation environment, DOE-2 validation, listing of free fenestration software from LBNL, Web sites for building energy efficiency, the heat balance method of calculating building heating and cooling loads.
ERIC Educational Resources Information Center
Petherbridge, P.
Formulas used in the calculation of cooling loads and indoor temperatures are employed to demonstrate the influence of various building parameters--such as thermal transmittance (U-value), solar absorptivity, and thermal storage--on the indoor thermal environment. The analysis leads to guidance on ways of limiting temperatures in naturally…
6. Detail view north of typical window and loading door ...
6. Detail view north of typical window and loading door at east end of south elevation. - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Auslander, David; Culler, David; Wright, Paul
The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Responsemore » (openADR), Auto-Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-to-building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov- March) and a steam absorption chiller for use in the warm months (April-October). Lighting in the open office areas is provided by direct-indirect luminaries with Building Management System-based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load during the study period was 1175 kW. Several new tools facilitated this work, such as the Smart Energy Box, the distributed load controller or Energy Information Gateway, the web-based DR controller (dubbed the Central Load-Shed Coordinator or CLSC), and the Demand Response Capacity Assessment & Operation Assistance Tool (DRCAOT). In addition, an innovative data aggregator called sMAP (simple Measurement and Actuation Profile) allowed data from different sources collected in a compact form and facilitated detailed analysis of the building systems operation. A smart phone application (RAP or Rapid Audit Protocol) facilitated an inventory of the building’s plug loads. Carbon dioxide sensors located in conference rooms and classrooms allowed demand controlled ventilation. The extensive submetering and nimble access to this data provided great insight into the details of the building operation as well as quick diagnostics and analyses of tests. For example, students discovered a short-cycling chiller, a stuck damper, and a leaking cooling coil in the first field tests. For our final field tests, we were able to see how each zone was affected by the DR strategies (e.g., the offices on the 7th floor grew very warm quickly) and fine-tune the strategies accordingly.« less
Dynamic Analysis of an Office Building due to Vibration from Road Construction Activities
NASA Astrophysics Data System (ADS)
Chik, T. N. T.; Kamil, M. R. H.; Yusoff, N. A.; Ibrahim, M. H. W.
2018-04-01
Construction activities are widely known as one of the predominant sources of man-made vibrations that able to create nuisance towards any adjacent building, and this includes the road construction operations. Few studies conclude the construction-induced vibration may be harmful directly and indirectly towards the neighbouring building. This lead to the awareness of study the building vibration response of concrete masonry load bearing system and its vibrational performance towards the road construction activities. This study will simulate multi-storey office building of Sekolah Menengah Kebangsaan (SMK) Bandar Enstek at Negeri Sembilan by using finite element vibration analyses. The excitation of transient loads from ground borne vibrations which triggered by the road construction activities are modelled into the building. The vibration response was recorded during in-situ ambient vibration test by using Laser Doppler Vibrometer (LDV), which specifically performed on four different locations. The finite element simulation process was developed in the commercial FEA software ABAQUS. Then, the experimental data was processed and evaluated in MATLAB ModalV to assess the vibration criteria of the floor in building. As a result, the vibration level of floor in building is fall under VC-E curve which was under the maximum permissible level for office building (VC-ISO). The vibration level on floor is acceptable within the limit that have been referred.
Effects of Cognitive Load on Trust
2013-10-01
that may be affected by load Build a parsing tool to extract relevant features Statistical analysis of results (by load components) Achieved...for a business application. Participants assessed potential job candidates and reviewed the applicants’ virtual resume which included standard...substantially different from each other that would make any confounding problems or other issues. Some statistics of the Australian data collection are
VOLATILE ORGANIC CHEMICALS IN 10 PUBLIC-ACCESS BUILDINGS
The U.S. EPA carried out studies of indoor air quality in 10 buildings. Qualitative analysis identified over 200 aromatics, halogens, esters, alcohols, phenols, ethers, ketones, aldehydes, and epoxides, in addition to several hundred aliphatic hydrocarbons. The total organic load...
Effects of ventilation behaviour on indoor heat load based on test reference years.
Rosenfelder, Madeleine; Koppe, Christina; Pfafferott, Jens; Matzarakis, Andreas
2016-02-01
Since 2003, most European countries established heat health warning systems to alert the population to heat load. Heat health warning systems are based on predicted meteorological conditions outdoors. But the majority of the European population spends a substantial amount of time indoors, and indoor thermal conditions can differ substantially from outdoor conditions. The German Meteorological Service (Deutscher Wetterdienst, DWD) extended the existing heat health warning system (HHWS) with a thermal building simulation model to consider heat load indoors. In this study, the thermal building simulation model is used to simulate a standardized building representing a modern nursing home, because elderly and sick people are most sensitive to heat stress. Different types of natural ventilation were simulated. Based on current and future test reference years, changes in the future heat load indoors were analyzed. Results show differences between the various ventilation options and the possibility to minimize the thermal heat stress during summer by using an appropriate ventilation method. Nighttime ventilation for indoor thermal comfort is most important. A fully opened window at nighttime and the 2-h ventilation in the morning and evening are more sufficient to avoid heat stress than a tilted window at nighttime and the 1-h ventilation in the morning and the evening. Especially the ventilation in the morning seems to be effective to keep the heat load indoors low. Comparing the results for the current and the future test reference years, an increase of heat stress on all ventilation types can be recognized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prowell, I.; Elgamal, A.; Romanowitz, H.
Demand parameters for turbines, such as tower moment demand, are primarily driven by wind excitation and dynamics associated with operation. For that purpose, computational simulation platforms have been developed, such as FAST, maintained by the National Renewable Energy Laboratory (NREL). For seismically active regions, building codes also require the consideration of earthquake loading. Historically, it has been common to use simple building code approaches to estimate the structural demand from earthquake shaking, as an independent loading scenario. Currently, International Electrotechnical Commission (IEC) design requirements include the consideration of earthquake shaking while the turbine is operating. Numerical and analytical tools usedmore » to consider earthquake loads for buildings and other static civil structures are not well suited for modeling simultaneous wind and earthquake excitation in conjunction with operational dynamics. Through the addition of seismic loading capabilities to FAST, it is possible to simulate earthquake shaking in the time domain, which allows consideration of non-linear effects such as structural nonlinearities, aerodynamic hysteresis, control system influence, and transients. This paper presents a FAST model of a modern 900-kW wind turbine, which is calibrated based on field vibration measurements. With this calibrated model, both coupled and uncoupled simulations are conducted looking at the structural demand for the turbine tower. Response is compared under the conditions of normal operation and potential emergency shutdown due the earthquake induced vibrations. The results highlight the availability of a numerical tool for conducting such studies, and provide insights into the combined wind-earthquake loading mechanism.« less
Effects of ventilation behaviour on indoor heat load based on test reference years
NASA Astrophysics Data System (ADS)
Rosenfelder, Madeleine; Koppe, Christina; Pfafferott, Jens; Matzarakis, Andreas
2016-02-01
Since 2003, most European countries established heat health warning systems to alert the population to heat load. Heat health warning systems are based on predicted meteorological conditions outdoors. But the majority of the European population spends a substantial amount of time indoors, and indoor thermal conditions can differ substantially from outdoor conditions. The German Meteorological Service (Deutscher Wetterdienst, DWD) extended the existing heat health warning system (HHWS) with a thermal building simulation model to consider heat load indoors. In this study, the thermal building simulation model is used to simulate a standardized building representing a modern nursing home, because elderly and sick people are most sensitive to heat stress. Different types of natural ventilation were simulated. Based on current and future test reference years, changes in the future heat load indoors were analyzed. Results show differences between the various ventilation options and the possibility to minimize the thermal heat stress during summer by using an appropriate ventilation method. Nighttime ventilation for indoor thermal comfort is most important. A fully opened window at nighttime and the 2-h ventilation in the morning and evening are more sufficient to avoid heat stress than a tilted window at nighttime and the 1-h ventilation in the morning and the evening. Especially the ventilation in the morning seems to be effective to keep the heat load indoors low. Comparing the results for the current and the future test reference years, an increase of heat stress on all ventilation types can be recognized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LeMar, P.
Integrated Energy Systems (IES) combine on-site power or distributed generation technologies with thermally activated technologies to provide cooling, heating, humidity control, energy storage and/or other process functions using thermal energy normally wasted in the production of electricity/power. IES produce electricity and byproduct thermal energy onsite, with the potential of converting 80 percent or more of the fuel into useable energy. IES have the potential to offer the nation the benefits of unprecedented energy efficiency gains, consumer choice and energy security. It may also dramatically reduce industrial and commercial building sector carbon and air pollutant emissions and increase source energy efficiency.more » Applications of distributed energy and Combined heat and power (CHP) in ''Commercial and Institutional Buildings'' have, however, been historically limited due to insufficient use of byproduct thermal energy, particularly during summer months when heating is at a minimum. In recent years, custom engineered systems have evolved incorporating potentially high-value services from Thermally Activated Technologies (TAT) like cooling and humidity control. Such TAT equipment can be integrated into a CHP system to utilize the byproduct heat output effectively to provide absorption cooling or desiccant humidity control for the building during these summer months. IES can therefore expand the potential thermal energy services and thereby extend the conventional CHP market into building sector applications that could not be economically served by CHP alone. Now more than ever, these combined cooling, heating and humidity control systems (IES) can potentially decrease carbon and air pollutant emissions, while improving source energy efficiency in the buildings sector. Even with these improvements over conventional CHP systems, IES face significant technological and economic hurdles. Of crucial importance to the success of IES is the ability to treat the heating, ventilation, air conditioning, water heating, lighting, and power systems loads as parts of an integrated system, serving the majority of these loads either directly or indirectly from the CHP output. The CHP Technology Roadmaps (Buildings and Industry) have focused research and development on a comprehensive integration approach: component integration, equipment integration, packaged and modular system development, system integration with the grid, and system integration with building and process loads. This marked change in technology research and development has led to the creation of a new acronym to better reflect the nature of development in this important area of energy efficiency: Integrated Energy Systems (IES). Throughout this report, the terms ''CHP'' and ''IES'' will sometimes be used interchangeably, with CHP generally reserved for the electricity and heat generating technology subsystem portion of an IES. The focus of this study is to examine the potential for IES in buildings when the system perspective is taken, and the IES is employed as a dynamic system, not just as conventional CHP. This effort is designed to determine market potential by analyzing IES performance on an hour-by-hour basis, examining the full range of building types, their loads and timing, and assessing how these loads can be technically and economically met by IES.« less
Load Diffusion in Composite and Smart Structures
NASA Technical Reports Server (NTRS)
Horgan, Cornelius O.; Ambur, D. (Technical Monitor); Nemeth, M. P. (Technical Monitor)
2003-01-01
The research carried out here builds on our previous NASA supported research on the general topic of edge effects and load diffusion in composite structures. Further fundamental solid mechanics studies were carried out to provide a basis for assessing the complicated modeling necessary for the multi-functional large scale structures used by NASA. An understanding of the fundamental mechanisms of load diffusion in composite subcomponents is essential in developing primary composite structures. Some specific problems recently considered were those of end effects in smart materials and structures, study of the stress response of pressurized linear piezoelectric cylinders for both static and steady rotating configurations, an analysis of the effect of pre-stressing and pre-polarization on the decay of end effects in piezoelectric solids and investigation of constitutive models for hardening rubber-like materials. Our goal in the study of load diffusion is the development of readily applicable results for the decay lengths in terms of non-dimensional material and geometric parameters. Analytical models of load diffusion behavior are extremely valuable in building an intuitive base for developing refined modeling strategies and assessing results from finite element analyses.
Wind tunnel tests for wind pressure distribution on gable roof buildings.
Jing, Xiao-kun; Li, Yuan-qi
2013-01-01
Gable roof buildings are widely used in industrial buildings. Based on wind tunnel tests with rigid models, wind pressure distributions on gable roof buildings with different aspect ratios were measured simultaneously. Some characteristics of the measured wind pressure field on the surfaces of the models were analyzed, including mean wind pressure, fluctuating wind pressure, peak negative wind pressure, and characteristics of proper orthogonal decomposition results of the measured wind pressure field. The results show that extremely high local suctions often occur in the leading edges of longitudinal wall and windward roof, roof corner, and roof ridge which are the severe damaged locations under strong wind. The aspect ratio of building has a certain effect on the mean wind pressure coefficients, and the effect relates to wind attack angle. Compared with experimental results, the region division of roof corner and roof ridge from AIJ2004 is more reasonable than those from CECS102:2002 and MBMA2006.The contributions of the first several eigenvectors to the overall wind pressure distributions become much bigger. The investigation can offer some basic understanding for estimating wind load distribution on gable roof buildings and facilitate wind-resistant design of cladding components and their connections considering wind load path.
Investigation of the seismic resistance of interior building partitions, phase 1
NASA Astrophysics Data System (ADS)
Anderson, R. W.; Yee, Y. C.; Savulian, G.; Barclay, B.; Lee, G.
1981-02-01
The effective participation of wood-framed interior shear wall partitions when determining the ultimate resistance capacity of two- and three-story masonry apartment buildings to seismic loading was investigated. Load vs. deflection tests were performed on 8 ft by 8 ft wall panel specimens constructed of four different facing materials, including wood lath and plaster, gypsum lath and plaster, and gypsum wallboard with joints placed either horizontally or vertically. The wood lath and plaster construction is found to be significantly stronger and stiffer than the other three specimens. Analyses of the test panels using finite element methods to predict their static resistance characteristics indicates that the facing material acts as the primary shear-resisting structural element. Resistance of shear wall partitions to lateral loads was assessed.
1. EAST ENTRANCE FROM LOADING AREA. CONCRETE TUNNEL TO TEST ...
1. EAST ENTRANCE FROM LOADING AREA. CONCRETE TUNNEL TO TEST STAND 1-3 IS AT RIGHT. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
7. Photograph is copy of historic photo (original print located ...
7. Photograph is copy of historic photo (original print located in Ogden Air Logistics Center, Hill Air Force Base, Utah). Photographer unknown. - Ogden Arsenal, Primer Loading Building for 37mm Shell Loading, 7726 North Carolina Way, Layton, Davis County, UT
VIEW OF 77710A REACTOR WING, LOOKING NORTHEAST,SHOWING LOADING DOOR TO ...
VIEW OF 777-10A REACTOR WING, LOOKING NORTHEAST,SHOWING LOADING DOOR TO THE PROCESS DEVELOPMENT PILE ROOM. BUILDING 305-A IN BACKGROUND ON LEFT - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Xin; Baker, Kyri A.; Christensen, Dane T.
This paper presents a user-preference-driven home energy management system (HEMS) for demand response (DR) with residential building loads and battery storage. The HEMS is based on a multi-objective model predictive control algorithm, where the objectives include energy cost, thermal comfort, and carbon emission. A multi-criterion decision making method originating from social science is used to quickly determine user preferences based on a brief survey and derive the weights of different objectives used in the optimization process. Besides the residential appliances used in the traditional DR programs, a home battery system is integrated into the HEMS to improve the flexibility andmore » reliability of the DR resources. Simulation studies have been performed on field data from a residential building stock data set. Appliance models and usage patterns were learned from the data to predict the DR resource availability. Results indicate the HEMS was able to provide a significant amount of load reduction with less than 20% prediction error in both heating and cooling cases.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Xin; Baker, Kyri A; Isley, Steven C
This paper presents a user-preference-driven home energy management system (HEMS) for demand response (DR) with residential building loads and battery storage. The HEMS is based on a multi-objective model predictive control algorithm, where the objectives include energy cost, thermal comfort, and carbon emission. A multi-criterion decision making method originating from social science is used to quickly determine user preferences based on a brief survey and derive the weights of different objectives used in the optimization process. Besides the residential appliances used in the traditional DR programs, a home battery system is integrated into the HEMS to improve the flexibility andmore » reliability of the DR resources. Simulation studies have been performed on field data from a residential building stock data set. Appliance models and usage patterns were learned from the data to predict the DR resource availability. Results indicate the HEMS was able to provide a significant amount of load reduction with less than 20% prediction error in both heating and cooling cases.« less
Loading estimates of lead, copper, cadmium, and zinc in urban runoff from specific sources.
Davis, A P; Shokouhian, M; Ni, S
2001-08-01
Urban stormwater runoff is being recognized as a substantial source of pollutants to receiving waters. A number of investigators have found significant levels of metals in runoff from urban areas, especially in highway runoff. As an initiatory study, this work estimates lead, copper, cadmium, and zinc loadings from various sources in a developed area utilizing information available in the literature, in conjunction with controlled experimental and sampling investigations. Specific sources examined include building siding and roofs; automobile brakes, tires, and oil leakage; and wet and dry atmospheric deposition. Important sources identified are building siding for all four metals, vehicle brake emissions for copper and tire wear for zinc. Atmospheric deposition is an important source for cadmium, copper, and lead. Loadings and source distributions depend on building and automobile density assumptions and the type of materials present in the area examined. Identified important sources are targeted for future comprehensive mechanistic studies. Improved information on the metal release and distributions from the specific sources, along with detailed characterization of watershed areas will allow refinements in the predictions.
28. BUILDING NO. 527, DEHYDRATING HOUSE, LOOKING SOUTH AT NORTH ...
28. BUILDING NO. 527, DEHYDRATING HOUSE, LOOKING SOUTH AT NORTH (REAR) ELEVATION OF PRELIMINARY SOLVENT RECOVERY WING. RAILS LEADING FROM DOORS CARRIED STANDARD GUAGE R.R. CARTS ONTO SMALL FLATCARS RIDING IN TRACKS IN FOREGROUND. FROM HERE THE CARS WERE TAKEN TO BUILDING NO. 533, SOLVENT RECOVERY. BUILDING NO. 540, LOADING DOCK (STORAGE FOR POWDER BUGGIES) IN BACKGROUND LEFT. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ
Fire development and wall endurance in sandwich and wood-frame structures
Carlton A. Holmes; Herbert W. Eickner; John J. Brenden; Curtis C. Peters; Robert H. White
1980-01-01
Large-scale fire tests were conducted on seven 16- by 24-foot structures. Four of these structures were of sandwich construction with cores of plastic or paper honeycomb and three were of wood-frame construction. The wasss were loaded to a computer design loading, and the fire endurance determined under a fire exposure from a typical building contents loading of 4-1/2...
Code of Federal Regulations, 2014 CFR
2014-01-01
... serve the load. Eligible borrower means a utility system that has direct or indirect responsibility for... analysis of energy flows in a building, process, or system with the goal of identifying opportunities to... output. HVAC means heating, ventilation, and air conditioning. Load means the Power delivered to power...
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Shaughnessy, Eric; Cutler, Dylan; Ardani, Kristen
As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt modelmore » is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.« less
O'Shaughnessy, Eric; Cutler, Dylan; Ardani, Kristen; ...
2018-01-11
As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt modelmore » is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.« less
Analysis of a digital RF memory in a signal-delay application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jelinek, D.A.
1992-03-01
Laboratory simulation of the approach of a radar fuze towards a target is an important factor in our ability to accurately measure the radar`s performance. This simulation is achieved, in part, by dynamically delaying and attenuating the radar`s transmitted pulse and sending the result back to the radar`s receiver. Historically, the device used to perform the dynamic delay has been a limiting factor in the evaluation of a radar`s performance and characteristics. A new device has been proposed that appears to have more capability than previous dynamic delay devices. This device is the digital RF memory. This report presents themore » results of an analysis of a digital RF memory used in a signal-delay application. 2 refs.« less
CARRIER/CASK HANDLING SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
E.F. Loros
2000-06-23
The Carrier/Cask Handling System receives casks on railcars and legal-weight trucks (LWTs) (transporters) that transport loaded casks and empty overpacks to the Monitored Geologic Repository (MGR) from the Carrier/Cask Transport System. Casks that come to the MGR on heavy-haul trucks (HHTs) are transferred onto railcars before being brought into the Carrier/Cask Handling System. The system is the interfacing system between the railcars and LWTs and the Assembly Transfer System (ATS) and Canister Transfer System (CTS). The Carrier/Cask Handling System removes loaded casks from the cask transporters and transfers the casks to a transfer cart for either the ATS or CTS,more » as appropriate, based on cask contents. The Carrier/Cask Handling System receives the returned empty casks from the ATS and CTS and mounts the casks back onto the transporters for reshipment. If necessary, the Carrier/Cask Handling System can also mount loaded casks back onto the transporters and remove empty casks from the transporters. The Carrier/Cask Handling System receives overpacks from the ATS loaded with canisters that have been cut open and emptied and mounts the overpacks back onto the transporters for disposal. If necessary, the Carrier/Cask Handling System can also mount empty overpacks back onto the transporters and remove loaded overpacks from them. The Carrier/Cask Handling System is located within the Carrier Bay of the Waste Handling Building System. The system consists of cranes, hoists, manipulators, and supporting equipment. The Carrier/Cask Handling System is designed with the tooling and fixtures necessary for handling a variety of casks. The Carrier/Cask Handling System performance and reliability are sufficient to support the shipping and emplacement schedules for the MGR. The Carrier/Cask Handling System interfaces with the Carrier/Cask Transport System, ATS, and CTS as noted above. The Carrier/Cask Handling System interfaces with the Waste Handling Building System for building structures and space allocations. The Carrier/Cask Handling System interfaces with the Waste Handling Building Electrical System for electrical power.« less
Architecture of high-rise buildings as a brand of the modern Kazakhstan
NASA Astrophysics Data System (ADS)
Abdrassilova, Gulnara; Kozbagarova, Nina; Tuyakayeva, Ainagul
2018-03-01
Using practical examples article reviews urban-planning and space-planning features of design and construction of high-rise buildings in Kazakhstan conditions; methods are identified that provide for structural stability against wind and seismic loads based on innovative technical and technological solutions. Article authors stress out the fashion function of high-rise buildings in the new capital of Kazakhstan, the Astana city.
After-hours power status of office equipment and energy use of miscellaneous plug-load equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.
2004-05-27
This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of miscellaneous plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers.more » For most types of miscellaneous equipment, we also estimated typical unit energy consumption in order to estimate total energy consumption of the miscellaneous devices within our sample. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from sixteen commercial buildings in California, Georgia, and Pennsylvania: four education buildings, two medical buildings, two large offices (> 500 employees each), three medium offices (50-500 employees each), and five small business offices (< 50 employees each). Two buildings are in the San Francisco Bay are a of California, nine (including the five small businesses) are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.« less
Strategy Guideline. Proper Water Heater Selection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoeschele, M.; Springer, D.; German, A.
2015-04-09
This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.
Strategy Guideline: Proper Water Heater Selection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoeschele, M.; Springer, D.; German, A.
2015-04-01
This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.
Building with integral solar-heat storage--Starkville, Mississippi
NASA Technical Reports Server (NTRS)
1981-01-01
Column supporting roof also houses rock-storage bin of solar-energy system supplying more than half building space heating load. Conventional heaters supply hot water. Since bin is deeper and narrower than normal, individual pebble size was increased to keep airflow resistance at minimum.
Evaluation of Advanced Polymers for Additive Manufacturing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rios, Orlando; Carter, William G.; Kutchko, Cindy
The goal of this Manufacturing Demonstration Facility (MDF) technical collaboration project between Oak Ridge National Laboratory (ORNL) and PPG Industries, Inc. (PPG) was to evaluate the feasibility of using conventional coatings chemistry and technology to build up material layer-by-layer. The PPG-ORNL study successfully demonstrated that polymeric coatings formulations may overcome many limitations of common thermoplastics used in additive manufacturing (AM), allow lightweight nozzle design for material deposition, and increase build rate. The materials effort focused on layer-by-layer deposition of coatings with each layer fusing together. The combination of materials and deposition results in an additively manufactured build that has sufficientmore » mechanical properties to bear the load of additional layers, yet is capable of bonding across the z-layers to improve build direction strength. The formulation properties were tuned to enable a novel, high-throughput deposition method that is highly scalable, compatible with high loading of reinforcing fillers, and inherently low-cost.« less
VIEW OF CRANE LOADING AND UNLOADING AREA OF FUEL STORAGE ...
VIEW OF CRANE LOADING AND UNLOADING AREA OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTH. INL PHOTO NUMBER HD-54-17-4. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
VIEW OF CRANE LOADING AND UNLOADING AREA OF FUEL STORAGE ...
VIEW OF CRANE LOADING AND UNLOADING AREA OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING SOUTH. INL PHOTO NUMBER HD-54-17-1. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, David Robert; Fensin, Saryu Jindal; Dippo, Olivia
Here, we present a study on the spall strength of additive manufactured (AM) Ti-6Al-4V. Samples were obtained from two pieces of selective laser melted (SLM, a powder bed fusion technique) Ti-6Al-4V such that the response to dynamic tensile loading could be investigated as a function of the orientation between the build layers and the loading direction. A sample of wrought bar-stock Ti-6Al-4V was also tested to act as a baseline representing the traditionally manufactured material response. A single-stage light gas-gun was used to launch a thin flyer plate into the samples, generating a region of intense tensile stress on amore » plane normal to the impact direction. The rear free surface velocity time history of each sample was recorded with laser-based velocimetry to allow the spall strength to be calculated. The samples were also soft recovered to enable post-mortem characterization of the spall damage evolution. Results showed that when the tensile load was applied normal to the interfaces between the build layers caused by the SLM fabrication process the spall strength was drastically reduced, dropping to 60% of that of the wrought material. However, when loaded parallel to the AM build layer interfaces the spall strength was found to remain at 95% of the wrought control, suggesting that when loading normal to the AM layer interfaces, void nucleation is facilitated more readily due to weaknesses along these boundaries. Quasi-static testing of the same sample orientations revealed a much lower degree of anisotropy, demonstrating the importance of rate-dependent studies for damage evolution in AM materials.« less
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1Receptacle loads and...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1 Receptacle loads and...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1Receptacle loads and...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1Receptacle loads and...
Looking East at BottomHalf of Reactor Number One and TopHalf ...
Looking East at Bottom-Half of Reactor Number One and Top-Half of Reactor Number 2 Including Weigh Hopper on Third Floor of Oxide Building - Hematite Fuel Fabrication Facility, Oxide Building & Oxide Loading Dock, 3300 State Road P, Festus, Jefferson County, MO
29 CFR 1926.758 - Systems-engineered metal buildings.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.758... systems-engineered metal buildings except §§ 1926.755 (column anchorage) and 1926.757 (open web steel... hoisting equipment is released. (d) Construction loads shall not be placed on any structural steel...
29 CFR 1926.758 - Systems-engineered metal buildings.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.758... systems-engineered metal buildings except §§ 1926.755 (column anchorage) and 1926.757 (open web steel... hoisting equipment is released. (d) Construction loads shall not be placed on any structural steel...
29 CFR 1926.758 - Systems-engineered metal buildings.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.758... systems-engineered metal buildings except §§ 1926.755 (column anchorage) and 1926.757 (open web steel... hoisting equipment is released. (d) Construction loads shall not be placed on any structural steel...
Extreme winds and tornadoes: an overview
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, J.R.
1985-01-01
The objective of this course on extreme winds, hurricanes and tornadoes is to provide an overview of these natural phenomenon from the perspective of design of new buildings and structures or the evaluation of existing ones. Information is directly applicable to design and evaluation processes. The premise is that the facility under consideration, which may consist of various buildings, structures, processing equipment, stacks, ventilation ducts, etc., can be classified into certain categories, depending on the importance of the mission performed in the facility or the hazard that is presented by the particular operation. Having classified the facility into an appropriatemore » category will automatically define certain design goals for the facility. The design goals are then met by selecting a design wind speed that is appropriate for the specified exceedance probability and by following certain specified design procedures. The problem then is to determine appropriate wind loads and other applicable loads, including dead loads, live loads, seismic loads and other loads that may act on the structures. The design process can then proceed in the usual manner. In the case of existing facilities the strengths of the various structural elements, subsystems and systems are evaluated and these strengths are related to wind speeds that would result in failure to meet the design goals. 12 refs.« less
Space Heaters, Computers, Cell Phone Chargers: How Plugged In AreCommercial Buildings?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez, Marla; Webber, Carrie; Brown, Richard
2007-02-28
Evidenceof electric plug loads in commercial buildings isvisible everyday: space heaters, portable fans, and the IT technician'stwo monitors connected to one PC. The Energy Information Administrationestimates that office and miscellaneous equipment together will consume2.18 quads in 2006, nearly 50 percent of U.S. commercial electricity use.Although the importance of commercial plug loads is documented, its verynature (diverse product types, products not installed when buildinginitially constructed, and products often hidden in closets) makes itdifficult to accurately count and categorize the end use.We auditedsixteen buildings in three cities (San Francisco, Atlanta, Pittsburgh)including office, medical and education building types. We inventoriedthe number and typesmore » of office and miscellaneous electric equipment aswell as estimated total energy consumption due to these product types. Intotal, we audited approximately 4,000 units of office equipment and 6,000units of miscellaneous equipment and covered a diverse range of productsranging from electric pencil sharpeners with a unit energy consumption(UEC) of 1 kWh/yr to a kiln with a UEC of 7,000 kWh/yr. Our paperpresents a summary of the density and type of plug load equipment foundas well as the estimated total energy consumption of the equipment.Additionally, we present equipment trends observed and provide insightsto how policy makers can target energy efficiency for this growing enduse.« less
NASA Astrophysics Data System (ADS)
Avci, Mesut
A practical cost and energy efficient model predictive control (MPC) strategy is proposed for HVAC load control under dynamic real-time electricity pricing. The MPC strategy is built based on a proposed model that jointly minimizes the total energy consumption and hence, cost of electricity for the user, and the deviation of the inside temperature from the consumer's preference. An algorithm that assigns temperature set-points (reference temperatures) to price ranges based on the consumer's discomfort tolerance index is developed. A practical parameter prediction model is also designed for mapping between the HVAC load and the inside temperature. The prediction model and the produced temperature set-points are integrated as inputs into the MPC controller, which is then used to generate signal actions for the AC unit. To investigate and demonstrate the effectiveness of the proposed approach, a simulation based experimental analysis is presented using real-life pricing data. An actual prototype for the proposed HVAC load control strategy is then built and a series of prototype experiments are conducted similar to the simulation studies. The experiments reveal that the MPC strategy can lead to significant reductions in overall energy consumption and cost savings for the consumer. Results suggest that by providing an efficient response strategy for the consumers, the proposed MPC strategy can enable the utility providers to adopt efficient demand management policies using real-time pricing. Finally, a cost-benefit analysis is performed to display the economic feasibility of implementing such a controller as part of a building energy management system, and the payback period is identified considering cost of prototype build and cost savings to help the adoption of this controller in the building HVAC control industry.
He, Zhi Chao; Huang, Shuo; Guo, Qing Hai; Xiao, Li Shan; Yang, De Wei; Wang, Ying; Yang, Yi Fu
2016-08-01
Urban sprawl has impacted increasingly on water environment quality in watersheds. Based on water environmental response, the simulation and prediction of expanding threshold of urban building land could provide an alternative reference for urban construction planning. Taking three watersheds (i.e., Yundang Lake at complete urbanization phase, Maluan Bay at peri-urbanization phase and Xinglin Bay at early urbanization phase) with 2009-2012 observation data as example, we calculated the upper limit of TN and TP capacity in three watersheds and identified the threshold value of urban building land in watersheds using the regional nutrient management (ReNuMa) model, and also predicted the water environmental effects associated with the changes of urban landscape pattern. Results indicated that the upper limit value of TN was 12900, 42800 and 43120 kg, while that of TP was 340, 420 and 450 kg for Yundang, Maluan and Xinglin watershed, respectively. In reality, the environment capacity of pollutants in Yundang Lake was not yet satura-ted, and annual pollutant loads in Maluan Bay and Xinglin Bay were close to the upper limit. How-ever, an obvious upward trend of annual TN and TP loads was observed in Xinglin Bay. The annual pollutant load was not beyond the annual upper limit in three watersheds under Scenario 1, while performed oppositely under Scenario 3. Under Scenario 2, the annual pollutant load in Yundang Lake was under-saturation, and the TN and TP in Maluan Bay were over their limits. The area thresholds of urban building land were 1320, 5600 and 4750 hm 2 in Yundang Lake, Maluan Bay and Xinglin Bay, respectively. This study could benefit the regulation on urban landscape planning.
NASA Astrophysics Data System (ADS)
Meng, Fanchao; Li, Mingcai; Cao, Jingfu; Li, Ji; Xiong, Mingming; Feng, Xiaomei; Ren, Guoyu
2017-06-01
Climate plays an important role in heating energy consumption owing to the direct relationship between space heating and changes in meteorological conditions. To quantify the impact, the Transient System Simulation Program software was used to simulate the heating loads of office buildings in Harbin, Tianjin, and Shanghai, representing three major climate zones (i.e., severe cold, cold, and hot summer and cold winter climate zones) in China during 1961-2010. Stepwise multiple linear regression was performed to determine the key climatic parameters influencing heating energy consumption. The results showed that dry bulb temperature (DBT) is the dominant climatic parameter affecting building heating loads in all three climate zones across China during the heating period at daily, monthly, and yearly scales (R 2 ≥ 0.86). With the continuous warming climate in winter over the past 50 years, heating loads decreased by 14.2, 7.2, and 7.1 W/m2 in Harbin, Tianjin, and Shanghai, respectively, indicating that the decreasing rate is more apparent in severe cold climate zone. When the DBT increases by 1 °C, the heating loads decrease by 253.1 W/m2 in Harbin, 177.2 W/m2 in Tianjin, and 126.4 W/m2 in Shanghai. These results suggest that the heating energy consumption can be well predicted by the regression models at different temporal scales in different climate conditions owing to the high determination coefficients. In addition, a greater decrease in heating energy consumption in northern severe cold and cold climate zones may efficiently promote the energy saving in these areas with high energy consumption for heating. Particularly, the likely future increase in temperatures should be considered in improving building energy efficiency.
Using Whole-House Field Tests to Empirically Derive Moisture Buffering Model Inputs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woods, J.; Winkler, J.; Christensen, D.
2014-08-01
Building energy simulations can be used to predict a building's interior conditions, along with the energy use associated with keeping these conditions comfortable. These models simulate the loads on the building (e.g., internal gains, envelope heat transfer), determine the operation of the space conditioning equipment, and then calculate the building's temperature and humidity throughout the year. The indoor temperature and humidity are affected not only by the loads and the space conditioning equipment, but also by the capacitance of the building materials, which buffer changes in temperature and humidity. This research developed an empirical method to extract whole-house model inputsmore » for use with a more accurate moisture capacitance model (the effective moisture penetration depth model). The experimental approach was to subject the materials in the house to a square-wave relative humidity profile, measure all of the moisture transfer terms (e.g., infiltration, air conditioner condensate) and calculate the only unmeasured term: the moisture absorption into the materials. After validating the method with laboratory measurements, we performed the tests in a field house. A least-squares fit of an analytical solution to the measured moisture absorption curves was used to determine the three independent model parameters representing the moisture buffering potential of this house and its furnishings. Follow on tests with realistic latent and sensible loads showed good agreement with the derived parameters, especially compared to the commonly-used effective capacitance approach. These results show that the EMPD model, once the inputs are known, is an accurate moisture buffering model.« less
NASA Astrophysics Data System (ADS)
Rovithis, Emmanouil; Kirtas, Emmanouil; Marini, Eleftheria; Bliziotis, Dimitris; Maltezos, Evangelos; Pitilakis, Dimitris; Makra, Konstantia; Savvaidis, Alexandros
2016-08-01
Airborne LiDAR monitoring integrated with field data is employed to assess the fundamental period and the seismic loading of structures composing an urban area under prescribed earthquake scenarios. Α piecewise work-flow is adopted by combining geometrical data of the building stock derived from a LiDAR-based 3D city model, structural data from in-situ inspections on representative city blocks and results of soil response analyses. The procedure is implemented in the residential area of Kalochori, (west of Thessaloniki in Northern Greece). Special attention is paid to the in-situ inspection of the building stock in order to discriminate recordings between actual buildings and man-made constructions that do not conform to seismic design codes and to acquire additional building stock data on structural materials, typologies and number of stories which is not feasible by the LiDAR process. The processed LiDAR and field data are employed to compute the fundamental period of each building by means of code-defined formulas. Knowledge of soil conditions in the Kalochoti area allows for soil response analyses to obtain free-field at ground surface under earthquake scenarios with varying return period. Upon combining the computed vibrational characteristics of the structures with the free-field response spectra, the seismic loading imposed on the structures of the urban area under investigation is derived for each one of the prescribed seismic motions. Results are presented in GIS environment in the form of spatially distributed spectral accelerations with direct implications in seismic vulnerability studies of an urban area.
The seasonal performance of a liquid-desiccant air conditioner
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowenstein, A.; Novosel, D.
1995-08-01
Prior reports on liquid-desiccant systems have focused on their steady-state operation at ARI design conditions. By studying their performance during an entire cooling season, the computer modeling presented here shows that liquid-desiccant systems can have a very high seasonal coefficient of performance (COP). For a liquid-desiccant system that uses a double-effect boiler, COPs ranging from 1.44 in a humid location (Houston) to 2.24 in a dry location (Phoenix) are achieved by fully exploiting indirect evaporative cooling and providing only the minimum latent cooling needed to meet the loads on the building. This minimizes the amount of water absorbed by themore » desiccant and, hence, the amount of thermal energy needed to regenerate it. In applications where latent loads are very high, such as processing the high volumes of ventilation air required to maintain good indoor air quality, the liquid-desiccant air conditioner again has an advantage over vapor-compression equipment. In this study, a liquid-desiccant system is modeled that cools and dehumidifies only the ventilation air of an office building in Atlanta. Although processing an airstream that is only 25% of the total air delivered to the building, the liquid-desiccant system is able to meet 52% of the building`s seasonal cooling requirements and reduce the building`s peak electrical demand by about 47%.« less
Response of Olive View Hospital to Northridge and Whittier earthquakes
Celebi, M.
1997-01-01
The purpose of this paper is to study the response of the conventionally designed new Olive View Medical Center (OVMC) building at 16 km from the epicenter of the January 17, 1994 Northridge, California earthquake (Ms = 6.8). OVMC is on an alluvial deposit. The building was subjected to design level peak accelerations during the earthquake and suffered only limited structural and nonstructural damage. The recorded motions at different levels of the OVMC building as well as its associated free-field sites are analyzed using spectral analyses and system identification techniques. The new OVMC building was conservatively designed in 1976 with very high lateral load resisting capability - particularly as a reaction to the detrimental fate of the original Olive View Hospital that was heavily damaged during the 1971 San Fernando earthquake. The original hospital building was later razed. The replacement structure, the new cross-shaped OVMC building, experienced peak acceleration of 2.31g at the roof while its peak ground floor acceleration was 0.82g. The free-field peak acceleration was 0.91g. The lateral load resisting system of the OVMC building consists of concrete shear walls in the lower two stories and steel shear walls at the perimeter of the upper four stories. Spectral analysis shows that this stiff structure was not affected by the long duration pulses of the motions recorded at this site.
Economic analysis of solar assisted absorption chiller for a commercial building
NASA Astrophysics Data System (ADS)
Antonyraj, Gnananesan
Dwindling fossil fuels coupled with changes in global climate intensified the drive to make use of renewable energy resources that have negligible impact on the environment. In this attempt, the industrial community produced various devices and systems to make use of solar energy for heating and cooling of building space as well as generate electric power. The most common components employed for collection of solar energy are the flat plate and evacuated tube collectors that produce hot water that can be employed for heating the building space. In order to cool the building, the absorption chiller is commonly employed that requires hot water at high temperatures for its operation. This thesis deals with economic analysis of solar collector and absorption cooling system to meet the building loads of a commercial building located in Chattanooga, Tennessee. Computer simulations are employed to predict the hourly building loads and performance of the flat plate and evacuated tube solar collectors using the hourly weather data. The key variables affecting the economic evaluation of such system are identified and the influence of these parameters is presented. The results of this investigation show that the flat plate solar collectors yield lower payback period compared to the evacuated tube collectors and economic incentives offered by the local and federal agencies play a major role in lowering the payback period.
Development of a Knowledge-Based System Approach for Decision Making in Construction Projects
1992-05-01
a generic model for an administrative facility and medical facility with predefined fixed building systems based on Air Force criteria and past...MAINTENANCE HANGAR (MEDIUM BAY) CORROSION CONTROL HANGAR (HIGH BAY) FUEL SYSTEM MAINTENANCE HANGAR (MEDIUM BAY) MEDICAL MODEL 82 Table 5-1--continued...BUILDING SUPPORT MEDICAL LOGISTICS MEDICAL TOTAL 85 Table 5-2--continued MISSILE ASSEMBLY AND MAINTENANCE BUILDING TOTAL MISSILE LOADING AND UNLOADING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pollock, E.O. Jr.
1987-10-15
The active solar Domestic Hot Water (DHW) system at the HQ Army-Air Force Exchange Service (AAFES) Building was designed and constructed as part of the Solar in Federal Buildings Programs (SFBP). This retrofitted system is one of eight of the systems in the SFBP selected for quality monitoring. The purpose of this monitoring effort is to document the performance of quality state-of-the-art solar systems in large federal building applications. The six-story HQ AAFES Building houses a cafeteria, officer's mess and club and office space for 2400 employees. The siphon-return drainback system uses 1147 ft/sup 2/ of Aircraftsman flat-plate collectors tomore » collect solar energy which is used to preheat domestic hot water. Solar energy is stored in a 1329-gallon tank and transferred to the hot water load through a heat exchanger located in the 356-gallon DHW preheat tank. Auxiliary energy is supplied by two gas fired boilers which boost the temperature to 130/sup 0/F before it is distributed to the load. Highlights of the performance of the HQ AAFES Building solar system during the monitoring period from August 1984 through May 1985 are presented in this report.« less
Wind Tunnel Tests for Wind Pressure Distribution on Gable Roof Buildings
2013-01-01
Gable roof buildings are widely used in industrial buildings. Based on wind tunnel tests with rigid models, wind pressure distributions on gable roof buildings with different aspect ratios were measured simultaneously. Some characteristics of the measured wind pressure field on the surfaces of the models were analyzed, including mean wind pressure, fluctuating wind pressure, peak negative wind pressure, and characteristics of proper orthogonal decomposition results of the measured wind pressure field. The results show that extremely high local suctions often occur in the leading edges of longitudinal wall and windward roof, roof corner, and roof ridge which are the severe damaged locations under strong wind. The aspect ratio of building has a certain effect on the mean wind pressure coefficients, and the effect relates to wind attack angle. Compared with experimental results, the region division of roof corner and roof ridge from AIJ2004 is more reasonable than those from CECS102:2002 and MBMA2006.The contributions of the first several eigenvectors to the overall wind pressure distributions become much bigger. The investigation can offer some basic understanding for estimating wind load distribution on gable roof buildings and facilitate wind-resistant design of cladding components and their connections considering wind load path. PMID:24082851
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stetiu, C.; Feustel, H.E.
1998-07-01
As thermal storage media, phase-change materials (PCMs) such as paraffin, eutectic salts, etc. offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. By embedding PCMs in dypsum board, plaster, or other wall-covering materials, the building structure acquires latent storage properties. Structural elements containing PCMs can store large amounts of energy while maintaining the indoor temperature within a relatively narrow range. As heat storage takes place inside the building where the loads occur, rather than at a central exterior location, the internal loads are removed without the need for additional transport energy. Distributed latent storage canmore » thus be used to reduce the peak power demand of a building, downsize the cooling system, and/or switch to low-energy cooling sources. The authors used RADCOOL, a thermal building simulation program based on the finite difference approach, to numerically evaluate the thermal performance of PCM wallboard coupled with mechanical night ventilation in office buildings offers the opportunity for system downsizing in climates where the outside air temperature drops below 18 C at night. In climates where the outside air temperature remains above 19 C at night, the use of PCM wallboard should be coupled with discharge mechanisms other than mechanical night ventilation with outside air.« less
24 CFR 3280.306 - Windstorm protection.
Code of Federal Regulations, 2014 CFR
2014-04-01
... vertical building projection, as horizontal wind load, and across the surface of the full roof structure... applied in the design of the tiedown system. The dead load of the structure may be used to resist these... manufacturer's installation instructions provide for the main frame structure to be used as the points for...
Predictive Optimal Control of Active and Passive Building Thermal Storage Inventory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gregor P. Henze; Moncef Krarti
2005-09-30
Cooling of commercial buildings contributes significantly to the peak demand placed on an electrical utility grid. Time-of-use electricity rates encourage shifting of electrical loads to off-peak periods at night and weekends. Buildings can respond to these pricing signals by shifting cooling-related thermal loads either by precooling the building's massive structure or the use of active thermal energy storage systems such as ice storage. While these two thermal batteries have been engaged separately in the past, this project investigated the merits of harnessing both storage media concurrently in the context of predictive optimal control. To pursue the analysis, modeling, and simulationmore » research of Phase 1, two separate simulation environments were developed. Based on the new dynamic building simulation program EnergyPlus, a utility rate module, two thermal energy storage models were added. Also, a sequential optimization approach to the cost minimization problem using direct search, gradient-based, and dynamic programming methods was incorporated. The objective function was the total utility bill including the cost of reheat and a time-of-use electricity rate either with or without demand charges. An alternative simulation environment based on TRNSYS and Matlab was developed to allow for comparison and cross-validation with EnergyPlus. The initial evaluation of the theoretical potential of the combined optimal control assumed perfect weather prediction and match between the building model and the actual building counterpart. The analysis showed that the combined utilization leads to cost savings that is significantly greater than either storage but less than the sum of the individual savings. The findings reveal that the cooling-related on-peak electrical demand of commercial buildings can be considerably reduced. A subsequent analysis of the impact of forecasting uncertainty in the required short-term weather forecasts determined that it takes only very simple short-term prediction models to realize almost all of the theoretical potential of this control strategy. Further work evaluated the impact of modeling accuracy on the model-based closed-loop predictive optimal controller to minimize utility cost. The following guidelines have been derived: For an internal heat gain dominated commercial building, reasonable geometry simplifications are acceptable without a loss of cost savings potential. In fact, zoning simplification may improve optimizer performance and save computation time. The mass of the internal structure did not show a strong effect on the optimization. Building construction characteristics were found to impact building passive thermal storage capacity. It is thus advisable to make sure the construction material is well modeled. Zone temperature setpoint profiles and TES performance are strongly affected by mismatches in internal heat gains, especially when they are underestimated. Since they are a key factor in determining the building cooling load, efforts should be made to keep the internal gain mismatch as small as possible. Efficiencies of the building energy systems affect both zone temperature setpoints and active TES operation because of the coupling of the base chiller for building precooling and the icemaking TES chiller. Relative efficiencies of the base and TES chillers will determine the balance of operation of the two chillers. The impact of mismatch in this category may be significant. Next, a parametric analysis was conducted to assess the effects of building mass, utility rate, building location and season, thermal comfort, central plant capacities, and an economizer on the cost saving performance of optimal control for active and passive building thermal storage inventory. The key findings are: (1) Heavy-mass buildings, strong-incentive time-of-use electrical utility rates, and large on-peak cooling loads will likely lead to attractive savings resulting from optimal combined thermal storage control. (2) By using economizer to take advantage of the cool fresh air during the night, the building electrical cost can be reduced by using less mechanical cooling. (3) Larger base chiller and active thermal storage capacities have the potential of shifting more cooling loads to off-peak hours and thus higher savings can be achieved. (4) Optimal combined thermal storage control with a thermal comfort penalty included in the objective function can improve the thermal comfort levels of building occupants when compared to the non-optimized base case. Lab testing conducted in the Larson HVAC Laboratory during Phase 2 showed that the EnergyPlus-based simulation was a surprisingly accurate prediction of the experiment. Therefore, actual savings of building energy costs can be expected by applying optimal controls from simulation results.« less
Control of Disturbing Loads in Residential and Commercial Buildings via Geometric Algebra
2013-01-01
Many definitions have been formulated to represent nonactive power for distorted voltages and currents in electronic and electrical systems. Unfortunately, no single universally suitable representation has been accepted as a prototype for this power component. This paper defines a nonactive power multivector from the most advanced multivectorial power theory based on the geometric algebra (GA). The new concept can have more importance on harmonic loads compensation, identification, and metering, between other applications. Likewise, this paper is concerned with a pioneering method for the compensation of disturbing loads. In this way, we propose a multivectorial relative quality index δ~ associated with the power multivector. It can be assumed as a new index for power quality evaluation, harmonic sources detection, and power factor improvement in residential and commercial buildings. The proposed method consists of a single-point strategy based of a comparison among different relative quality index multivectors, which may be measured at the different loads on the same metering point. The comparison can give pieces of information with magnitude, direction, and sense on the presence of disturbing loads. A numerical example is used to illustrate the clear capabilities of the suggested approach. PMID:24260017
Control of disturbing loads in residential and commercial buildings via geometric algebra.
Castilla, Manuel-V
2013-01-01
Many definitions have been formulated to represent nonactive power for distorted voltages and currents in electronic and electrical systems. Unfortunately, no single universally suitable representation has been accepted as a prototype for this power component. This paper defines a nonactive power multivector from the most advanced multivectorial power theory based on the geometric algebra (GA). The new concept can have more importance on harmonic loads compensation, identification, and metering, between other applications. Likewise, this paper is concerned with a pioneering method for the compensation of disturbing loads. In this way, we propose a multivectorial relative quality index δ(~) associated with the power multivector. It can be assumed as a new index for power quality evaluation, harmonic sources detection, and power factor improvement in residential and commercial buildings. The proposed method consists of a single-point strategy based of a comparison among different relative quality index multivectors, which may be measured at the different loads on the same metering point. The comparison can give pieces of information with magnitude, direction, and sense on the presence of disturbing loads. A numerical example is used to illustrate the clear capabilities of the suggested approach.
Failure mechanism of shear-wall dominant multi-story buildings
Yuksel, S.B.; Kalkan, E.
2008-01-01
The recent trend in the building industry of Turkey as well as in many European countries is towards utilizing the tunnel form (shear-wall dominant) construction system for development of multi-story residential units. The tunnel form buildings diverge from other conventional reinforced concrete (RC) buildings due to the lack of beams and columns in their structural integrity. The vertical load-carrying members of these buildings are the structural-walls only, and the floor system is a flat plate. Besides the constructive advantages, tunnel form buildings provide superior seismic performance compared to conventional RC frame and dual systems as observed during the recent devastating earthquakes in Turkey (1999 Mw 7.4 Kocaeli, Mw 7.2 Duzce, and 2004 Mw 6.5 Bingol). With its proven earthquake performance, the tunnel form system is becoming the primary construction technique in many seismically active regions. In this study, a series of nonlinear analyses were conducted using finite element (FE) models to augment our understanding on their failure mechanism under lateral forces. In order to represent the nonlinear behavior adequately, The FE models were verified with the results of experimental studies performed on three dimensional (3D) scaled tunnel form building specimens. The results of this study indicate that the structural walls of tunnel form buildings may exhibit brittle flexural failure under lateral loading, if they are not properly reinforced. The global tension/compression couple triggers this failure mechanism by creating pure axial tension in the outermost shear-walls.
Challenges in Commercial Buildings | Buildings | NREL
generation prototype desiccant-enhanced evaporative air conditioner that links to a fact sheet about NREL's Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants . Photo of a SolarWall solar ventilation air preheating system on the AVUM helicopter maintenance hangar
Photovoltaic electricity generation: Value for residential and commercial sectors
NASA Astrophysics Data System (ADS)
Bhattacharjee, Ujjwal
The photovoltaic (PV) industry in the US has seen an upsurge in recent years, and PV holds great promise as a renewable technology with no greenhouse gas emissions with its use. We aim to assess the value of PV based electricity for users in the residential and commercial sectors focusing on the financial impacts it has, which may not be greatly recognized. Specifically, we pursue two goals. First, the emerging 'renewable portfolio standard (RPS)' adopted in several states in the country has been a driving force for large scale PV deployment, but financial incentives offered to PV in different RPS states differ considerably. We use life cycle cost model to estimate the cost of PV based electricity for thirty-two RPS states in the country. Results indicate that the levelized cost of PV electricity is high (40 to 60 Cents/kWh). When the contribution of the financial incentives (along with the cost of energy saved) is taken into account, the cost of PV based electricity is negative in some RPS states such as California, New Jersey, New York, while for most of the RPS states the cost of PV electricity continues to remain high. In addition, the states with negative or low cost of PV electricity have been driving the PV diffusion in the residential sector. Therefore, a need to adjust the financial incentive structure in different RPS states is recommended for homogenous development of the residential PV market in the country. Second, we assess the value of the PV in reducing the highest peak load demand in commercial buildings and hence the high value demand charge. The Time-of-Use (TOU) based electricity tariff is widely used by electric utilities in the commercial sector. Energy and peak load are two important facets of the TOU tariff regime. Tools are well established to estimate the energy contribution from a PV system (installed in a commercial building), but not power output on a short time interval. A joint conditional probability model has been developed that enables estimation of the PV contribution towards the peak load reduction for a given high building load. Results indicate a significant cost saving (15% to 40%) with application of the model. This will encourage commercial entities (building owners) to adopt PV as a distributed energy source. The tool would be useful for energy modelers and green building architects as it will enable them to estimate cost savings due to PV deployment in commercial buildings. Moreover, the model tested for three different commercial buildings indicates that school buildings show the best promise for PV deployment followed, respectively, by office buildings and manufacturing facilities. This will help PV incentive programs in the country to use resources effectively to enhance the diffusion of PV in the commercial sector.
NASA Astrophysics Data System (ADS)
Huang, Bo; Zhai, Yutao; Liu, Shaojun; Mao, Xiaodong
2018-03-01
Selective laser melting (SLM) is a promising way for the fabrication of complex reduced activation ferritic/martensitic steel components. The microstructure of the SLM built China low activation martensitic (CLAM) steel plates was observed and analyzed. The hardness, Charpy impact and tensile testing of the specimens in different orientations were performed at room temperature. The results showed that the difference in the mechanical properties was related to the anisotropy in microstructure. The planer unmelted porosity in the interface of the adjacent layers induced opening/tensile mode when the tensile samples parallel to the build direction were tested whereas the samples vertical to the build direction fractured in the shear mode with the grains being sheared in a slant angle. Moreover, the impact absorbed energy (IAE) of all impact specimens was significantly lower than that of the wrought CLAM steel, and the IAE of the samples vertical to the build direction was higher than that of the samples parallel to the build direction. The impact fracture surfaces revealed that the load parallel to the build layers caused laminated tearing among the layers, and the load vertical to the layers induced intergranular fracture across the layers.
Data-driven forecasting algorithms for building energy consumption
NASA Astrophysics Data System (ADS)
Noh, Hae Young; Rajagopal, Ram
2013-04-01
This paper introduces two forecasting methods for building energy consumption data that are recorded from smart meters in high resolution. For utility companies, it is important to reliably forecast the aggregate consumption profile to determine energy supply for the next day and prevent any crisis. The proposed methods involve forecasting individual load on the basis of their measurement history and weather data without using complicated models of building system. The first method is most efficient for a very short-term prediction, such as the prediction period of one hour, and uses a simple adaptive time-series model. For a longer-term prediction, a nonparametric Gaussian process has been applied to forecast the load profiles and their uncertainty bounds to predict a day-ahead. These methods are computationally simple and adaptive and thus suitable for analyzing a large set of data whose pattern changes over the time. These forecasting methods are applied to several sets of building energy consumption data for lighting and heating-ventilation-air-conditioning (HVAC) systems collected from a campus building at Stanford University. The measurements are collected every minute, and corresponding weather data are provided hourly. The results show that the proposed algorithms can predict those energy consumption data with high accuracy.
Chilled water study EEAP program for Walter Reed Army Medical Center: Book 2. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-02-01
The Energy Engineering Analysis Program (EEAP) Study for Walter Reed Army Medical Center (WRAMC) was to provide a thorough examination of the central chilled water plants on site. WRAMC is comprised of seventy-one (71) buildings located on a 113-acre site in Washington, D.C. There are two (2) central chilled water plants (Buildings 48 and 49) each with a primary chilled water distribution system. In addition to the two (2) central plants, three (3) buildings utilize their own independent chillers. Two (2) of the independent chillers (Buildings 7 and T-2), one of which is inoperative (T-2), are smaller air-cooled units, whilemore » the third (Building 54) has a 1,900-ton chilled water plant comprised of three (3) centrifugal chillers. Of the two (2) central chilled water plants, Building 48 houses six (6) chillers totalling 7,080 tons of cooling and Building 49 houses one (1) chiller with 660 tons of cooling. The total chiller cooling capacity available on site is 9,840 tons. The chilled water systems were reviewed for alternative ways of conserving energy on site and reducing the peak-cooling load. Distribution systems were reviewed to determine which buildings were served by each of the chilled water plants and to determine chilled water usage on site. Evaluations were made of building exterior and interior composition in order to estimate cooling loads. Interviews with site personnel helped Entech better understand the chilled water plants, the distribution systems, and how each system was utilized.« less
Small Scale Solar Cooling Unit in Climate Conditions of Latvia: Environmental and Economical Aspects
NASA Astrophysics Data System (ADS)
Jaunzems, Dzintars; Veidenbergs, Ivars
2010-01-01
The paper contributes to the analyses from the environmental and economical point of view of small scale solar cooling system in climate conditions of Latvia. Cost analyses show that buildings with a higher cooling load and full load hours have lower costs. For high internal gains, cooling costs are around 1,7 €/kWh and 2,5 €/kWh for buildings with lower internal gains. Despite the fact that solar cooling systems have significant potential to reduce CO2 emissions due to a reduction of electricity consumption, the economic feasibility and attractiveness of solar cooling system is still low.
Progressive Fracture of Fiber Composite Build-Up Structures
NASA Technical Reports Server (NTRS)
Gotsis, Pascal K.; Chamis, C. C.; Minnetyan, Levon
1997-01-01
Damage progression and fracture of built-up composite structures is evaluated by using computational simulation. The objective is to examine the behavior and response of a stiffened composite (0/ +/- 45/90)(sub s6) laminate panel by simulating the damage initiation, growth, accumulation, progression and propagation to structural collapse. An integrated computer code, CODSTRAN, was augmented for the simulation of the progressive damage and fracture of built-up composite structures under mechanical loading. Results show that damage initiation and progression have significant effect on the structural response. Influence of the type of loading is investigated on the damage initiation, propagation and final fracture of the build-up composite panel.
Progressive Fracture of Fiber Composite Build-Up Structures
NASA Technical Reports Server (NTRS)
Minnetyan, Levon; Gotsis, Pascal K.; Chamis, C. C.
1997-01-01
Damage progression and fracture of built-up composite structures is evaluated by using computational simulation. The objective is to examine the behavior and response of a stiffened composite (0 +/-45/90)(sub s6) laminate panel by simulating the damage initiation, growth, accumulation, progression and propagation to structural collapse. An integrated computer code CODSTRAN was augmented for the simulation of the progressive damage and fracture of built-up composite structures under mechanical loading. Results show that damage initiation and progression to have significant effect on the structural response. Influence of the type of loading is investigated on the damage initiation, propagation and final fracture of the build-up composite panel.
NASA Astrophysics Data System (ADS)
Albatayneh, Aiman; Alterman, Dariusz; Page, Adrian; Moghtaderi, Behdad
2017-05-01
The design of low energy buildings requires accurate thermal simulation software to assess the heating and cooling loads. Such designs should sustain thermal comfort for occupants and promote less energy usage over the life time of any building. One of the house energy rating used in Australia is AccuRate, star rating tool to assess and compare the thermal performance of various buildings where the heating and cooling loads are calculated based on fixed operational temperatures between 20 °C to 25 °C to sustain thermal comfort for the occupants. However, these fixed settings for the time and temperatures considerably increase the heating and cooling loads. On the other hand the adaptive thermal model applies a broader range of weather conditions, interacts with the occupants and promotes low energy solutions to maintain thermal comfort. This can be achieved by natural ventilation (opening window/doors), suitable clothes, shading and low energy heating/cooling solutions for the occupied spaces (rooms). These activities will save significant amount of operating energy what can to be taken into account to predict energy consumption for a building. Most of the buildings thermal assessment tools depend on energy-based approaches to predict the thermal performance of any building e.g. AccuRate in Australia. This approach encourages the use of energy to maintain thermal comfort. This paper describes the advantages of a temperature-based approach to assess the building's thermal performance (using an adaptive thermal comfort model) over energy based approach (AccuRate Software used in Australia). The temperature-based approach was validated and compared with the energy-based approach using four full scale housing test modules located in Newcastle, Australia (Cavity Brick (CB), Insulated Cavity Brick (InsCB), Insulated Brick Veneer (InsBV) and Insulated Reverse Brick Veneer (InsRBV)) subjected to a range of seasonal conditions in a moderate climate. The time required for heating and/or cooling using the adaptive thermal comfort approach and AccuRate predictions were estimated. Significant savings (of about 50 %) in energy consumption in minimising the time required for heating and cooling were achieved by using the adaptive thermal comfort model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaplanis, S., E-mail: kaplanis@teipat.gr; Kaplani, E.
The paper presents the design features, the energy modelling and optical performance details of two pilot Intelligent Energy Buildings, (IEB). Both are evolution of the Zero Energy Building (ZEB) concept. RES innovations backed up by signal processing, simulation models and ICT tools were embedded into the building structures in order to implement a new predictive energy management concept. In addition, nano-coatings, produced by TiO2 and ITO nano-particles, were deposited on the IEB structural elements and especially on the window panes and the PV glass covers. They exhibited promising SSP values which lowered the cooling loads and increased the PV modulesmore » yield. Both pilot IEB units were equipped with an on-line dynamic hourly solar radiation prediction model, implemented by sensors and the related software to manage effectively the energy source, the loads and the storage or the backup system. The IEB energy sources covered the thermal loads via a south façade embedded in the wall and a solar roof which consists of a specially designed solar collector type, while a PV generator is part of the solar roof, like a compact BIPV in hybrid configuration to a small wind turbine.« less
A Study towards Building An Optimal Graph Theory Based Model For The Design of Tourism Website
NASA Astrophysics Data System (ADS)
Panigrahi, Goutam; Das, Anirban; Basu, Kajla
2010-10-01
Effective tourism website is a key to attract tourists from different parts of the world. Here we identify the factors of improving the effectiveness of website by considering it as a graph, where web pages including homepage are the nodes and hyperlinks are the edges between the nodes. In this model, the design constraints for building a tourism website are taken into consideration. Our objectives are to build a framework of an effective tourism website providing adequate level of information, service and also to enable the users to reach to the desired page by spending minimal loading time. In this paper an information hierarchy specifying the upper limit of outgoing link of a page has also been proposed. Following the hierarchy, the web developer can prepare an effective tourism website. Here loading time depends on page size and network traffic. We have assumed network traffic as uniform and the loading time is directly proportional with page size. This approach is done by quantifying the link structure of a tourism website. In this approach we also propose a page size distribution pattern of a tourism website.
Upgrading Basements for Combined Nuclear Weapons Effects: Expedient Options
1976-05-01
reinforced concrete stairwell walls can be expected to be substantial in these cases, since they are supporting an axial load from higher floors. F...desirability) include: a. Stacked concrete block or brick b. Stacked timber * The latter situation is likely to occur only in load - bearing wall...concrete flat slab 4 Reinforced concrete flat plate 4 Load - bearing wall 3 The analysis of the floor systems for the 34 NSS buildings required the dynamic
Design Analysis of a Prepackaged Nuclear Power Plant for an Ice Cap Location
1959-01-15
requirements and heating load 1.3 Site Conditions 1,U Air Transportability 1.5 Standby Power Availability 1.6 Building Structuree and Foundations 2,0...Skid with Reactor and Steam Generator Generator Weight Distribution Foundation Load Diagram (Secondary) Turbine Generator Package - Typical...Requirements and Heating Load The plant shall be capable of producing a minimum of 1500 Kw net ^ electrical energy at 4160/2400 volts, three phase
NASA Astrophysics Data System (ADS)
Kala, J.; Bajer, M.; Barnat, J.; Smutný, J.
2010-12-01
Pedestrian-induced vibrations are a criterion for serviceability. This loading is significant for light-weight footbridge structures, but was established as a basic loading for the ceilings of various ordinary buildings. Wide variations of this action exist. To verify the different conclusions of various authors, vertical pressure measurements invoked during walking were performed. In the article the approaches of different design codes are also shown.
Design description of the Schuchuli Village photovoltaic power system
NASA Technical Reports Server (NTRS)
Ratajczak, A. F.; Vasicek, R. W.; Delombard, R.
1981-01-01
A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.
1980-08-01
orientation, and HVAC systems have on three Army buildings in five different climatic regions. f Optimization of EnerV Usage in Military Facilities...The clinic’s environment is maintained by a multizone air-handling unit served by its own boiler and chiller . The building was modeled with 30... setpoints for the space temperature. This type of throttling range allows the heating system to control around a throttling range of 67 to 69oF (19 to 200
Measure Guideline. Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rudd, Armin
2012-08-01
This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.
Automatic remote-integration metering center. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Philippidis, P.A.; Weinreb, M.; de Gil, B.F.
1988-11-01
The report documents a multi-phase program for the development and demonstration of a unique automatic and remote metering system. The system consists of a solid-state meter module to provide electrical consumption data, tamper detection, and load control functions; a central master station to interrogate the meter modules for their data and also to transmit load control signals; and a data display module to be accessible to tenants wishing to obtain their meter readings. The system has the capability to measure and allocate demand and to process time of use rates. It also has a meter accuracy self-test feature. The systemmore » is suitable for both direct metering of multi-family buildings and the sub-metering of master-metered apartment buildings. In addition to describing the system, the report documents the results of a 371-point field trial at Scott Tower, a cooperative apartment building in the Bronx, New York.« less
Studies on effects of infills in seismic resistant R/C construction
NASA Astrophysics Data System (ADS)
Brokken, S. T.; Bertero, V. V.
1981-10-01
Experimental and analytical studies of the quantitative effects of infills in the seismic performance of buildings (particularly in buildings whose structural systems are based on the use of moment resisting frames alone are summarized); and the implications of these effects regarding the design of new buildings and retrofitting of existing R/C frame structures were evaluated. The first part is concerned with the infill problem and the experimental investigation conducted to study the effects of infill panels on seismic response of reinforced concrete frames. This investigation consisted of a series of quasi-static cyclic and monotonic load tests on 1/3-scale models of the lower 3-1/2 stories of an 11 story-three bay reinforced concrete frame infilled in the outer two bays. The reinforced concrete moment frame was designed for high rotational ductility and resistance to degradation under reversed cyclic shear loads.
Laboratory testing of a building envelope segment based on cellular concrete
NASA Astrophysics Data System (ADS)
Fořt, Jan; Pavlík, Zbyšek; Černý, Robert
2016-07-01
Hygrothermal performance of a building envelope based on cellular concrete blocks is studied in the paper. Simultaneously, the strain fields induced by the heat and moisture changes are monitored. The studied wall is exposed to the climatic load corresponding to the winter climatic conditions of the moderate year for Prague. The winter climatic exposure is chosen in order to simulate the critical conditions of the building structure from the point of view of material performance and temperature and humidity loading. The evaluation of hygrothermal performance of a researched wall is done on the basis of relative humidity and temperature profiles measured along the cross section of the cellular concrete blocks. Strain gauges are fixed on the wall surface in expected orientation of the blocks expansion. The obtained results show a good hygrothermal function of the analyzed cellular concrete wall and its insignificant strain.
BLAST: Building energy simulation in Hong Kong
NASA Astrophysics Data System (ADS)
Fong, Sai-Keung
1999-11-01
The characteristics of energy use in buildings under local weather conditions were studied and evaluated using the energy simulation program BLAST-3.0. The parameters used in the energy simulation for the study and evaluation include the architectural features, different internal building heat load settings and weather data. In this study, mathematical equations and the associated coefficients useful to the industry were established. A technology for estimating energy use in buildings under local weather conditions was developed by using the results of this study. A weather data file of Typical Meteorological Years (TMY) has been compiled for building energy studies by analyzing and evaluating the weather of Hong Kong from the year 1979 to 1988. The weather data file TMY and the example weather years 1980 and 1988 were used by BLAST-3.0 to evaluate and study the energy use in different buildings. BLAST-3.0 was compared with other building energy simulation and approximation methods: Bin method and Degree Days method. Energy use in rectangular compartments of different volumes varying from 4,000 m3 to 40,000 m3 with different aspect ratios were analyzed. The use of energy in buildings with concrete roofs was compared with those with glass roofs at indoor temperature 21°C, 23°C and 25°C. Correlation relationships among building energy, space volume, monthly mean temperature and solar radiation were derived and investigated. The effects of space volume, monthly mean temperature and solar radiation on building energy were evaluated. The coefficients of the mathematical relationships between space volume and energy use in a building were computed and found satisfactory. The calculated coefficients can be used for quick estimation of energy use in buildings under similar situations. To study energy use in buildings, the cooling load per floor area against room volume was investigated. The case of an air-conditioned single compartment with 5 m ceiling height was evaluated. It was found that the supply of cool air to the lower portion of the compartment provided significant performance of space cooling. The mathematical relationships between different shading patterns and different glass window to wall ratios of single compartments were established to provide a guide for easy approximation of energy use under similar conditions. In addition, the Overall Thermal Transfer Values (OTTV) for the compartments were studied. The monthly and annual energy use of three realistic buildings were investigated. They were a commercial building, an industrial building and a dual-purpose building. The cooling loads per floor area for the buildings were studied and the OTTV were evaluated by two different methods. Sensitivity analysis was carried out to investigate the impact of the parameters of internal heat gains on the energy use of an academic building. It was found that there was major influence of indoor temperature setting on building energy use The performances of using the local weather data file of TMY and example weather years 1980 and 1989 were evaluated. TMY was found to be the most suitable for energy simulation while the weather years 1980 and 1989 yielded good results.
ERIC Educational Resources Information Center
Likourezos, Vicki; Kalyuga, Slava
2017-01-01
According to cognitive load theory, using worked examples is an effective and efficient instructional strategy for initial cognitive skill acquisition for novice learners, as it reduces cognitive load and frees up cognitive resources to build task competence. Contrary to this, productive failure (as well as invention learning, desirable…
A Knowledge Conversion Model Based on the Cognitive Load Theory for Architectural Design Education
ERIC Educational Resources Information Center
Wu, Yun-Wu; Liao, Shin; Wen, Ming-Hui; Weng, Kuo-Hua
2017-01-01
The education of architectural design requires balanced curricular arrangements of respectively theoretical knowledge and practical skills to really help students build their knowledge structures, particularly helping them in solving the problems of cognitive load. The purpose of this study is to establish an architectural design knowledge…
End Effects and Load Diffusion in Composite Structures
NASA Technical Reports Server (NTRS)
Horgan, Cornelius O.; Ambur, D. (Technical Monitor); Nemeth, M. P. (Technical Monitor)
2002-01-01
The research carried out here builds on our previous NASA supported research on the general topic of edge effects and load diffusion in composite structures. Further fundamental solid mechanics studies were carried out to provide a basis for assessing the complicated modeling necessary for large scale structures used by NASA. An understanding of the fundamental mechanisms of load diffusion in composite subcomponents is essential in developing primary composite structures. Specific problems recently considered were focussed on end effects in sandwich structures and for functionally graded materials. Both linear and nonlinear (geometric and material) problems have been addressed. Our goal is the development of readily applicable design formulas for the decay lengths in terms of non-dimensional material and geometric parameters. Analytical models of load diffusion behavior are extremely valuable in building an intuitive base for developing refined modeling strategies and assessing results from finite element analyses. The decay behavior of stresses and other field quantities provides a significant aid towards this process. The analysis is also amenable to parameter study with a large parameter space and should be useful in structural tailoring studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luke Chen; Hsu-Cheng Chang
An air pollutant (CO) distribution in a typical street canyon is simulated to evaluate pedestrian exposure. In this study, we consider factors those may affect the pollutant distribution in a typical street canyon. The considered factors include aspect ratio of a street canyon, atmospheric stability, traffic load and turbulent buoyancy effect. A two-dimensional domain that includes suburban roughness and urban street canyon is considered. The factors such as atmospheric stability, traffic load and turbulent buoyancy are imposed through the associated boundary conditions. With numerical simulation, the critical aspect ration of a street canyon the includes two vortices and results inmore » pollutant accumulation are found. The buoyant effect is found to raise the same pollutant concentration up to the position higher than the results come out from the case without buoyancy. The pedestrian exposure to the street air pollutant under various traffic loads and atmospheric stability are evaluated. This study conclude that the local building regulations that specify the building height/street width ratio will not cause significant pedestrian exposure to the street air pollution in most of traffic loads and atmospheric stability conditions.« less
NASA Astrophysics Data System (ADS)
Menicovich, David
By 2050 an estimated 9 billion people will inhabit planet earth and almost all the growth in the next 40 years will be in urban areas putting tremendous pressure on creating sustainable cities. The rapid increase in population, rise in land value and decrease in plot sizes in cities around the world positions tall or more importantly slender buildings as the best suited building typology to address the increasingly critical demand for space in this pressing urbanization trend. However, the majority of new tall building urban developments have not followed principles of environmental and/or sustainable design and incentives to innovate, both technological and economic, are urgently required. The biggest climatic challenge to the design, construction and performance of tall buildings is wind sensitivity. This challenge is further emphasized seeing two market driven trends: on one hand as urban population grows, land value rises while plot sizes decrease; on the other, more cost effective modular construction techniques are introducing much lighter tall building structures. The combination of the two suggests a potential increase in the slenderness ratio of tall buildings (typically less than 6:1 but stretching to 20:1 in the near future) where not-so-tall but much lighter buildings will be the bulk of new construction in densely populated cities, providing affordable housing in the face of fast urbanization but also introducing wind sensitivity which was previously the problem of a very limited number of super tall buildings to a much larger number of buildings and communities. The proposed research aims to investigate a novel approach to the interaction between tall buildings and their environment. Through this approach the research proposes a new relationship between buildings and the flows around, through and inside them, where buildings could adapt to better control and manage the air flow around them, and consequently produce significant opportunities to reduce material and energy consumption profiles of tall building. To date, the increasing use of light-weight and high-strength materials in tall buildings, with greater flexibility and reduced damping, has increased susceptibility to dynamic wind load effects that limit the gains afforded by incorporating these new materials. Wind, particularly fluctuating wind and its interaction with buildings induces two main responses; alongwind - in the direction of the flow and crosswind - perpendicular to the flow. The main risk associated with this vulnerability is resonant oscillations induced by von-Karman-like vortex shedding at or near the natural frequency of the structure caused by flow separation. Dynamic wind loading effects often increase with a power of wind speed greater than 3, thus increasingly, tall buildings pay a significant price in material to increase the natural frequency and/or the damping to overcome this response. In particular, crosswind response often governs serviceability (human habitability) design criteria of slender buildings. Currently, reducing crosswind response relies on a Solid-based Aerodynamic Modification (SAM), either by changing structural or geometric characteristics such as the tower shape or through the addition of damping systems. While this approach has merit it has two major drawbacks: firstly, the loss of valuable rentable areas and high construction costs due to increased structural requirements for mass and stiffness, further contributing towards the high consumption of non-renewable resources by the commercial building sector. For example, in order to insure human comfort within an acceptable range of crosswind response induced accelerations at the top of a building, an aerodynamically efficient plan shape comes at the expense of floor area. To compensate for the loss of valuable area compensatory stories are required, resulting in an increase in wind loads and construction costs. Secondly, a limited, if at all, ability to adaptively respond to fluctuating environmental conditions such as changes in wind direction or velocity over the height of building which could be of consequence if the conditions for which the building was designed for change due to, for example, changes in the built environment surrounding it. Fluidic-based Aerodynamic Modification (FAM) is a fundamentally different approach; instead of adjusting the solid material to improve the aerodynamic 'shape' of the structure, fluid-based flow control is used to manipulate the boundary layer characteristics. The local flow field is modified to 'view' the solid as a different shape, and thus, that solid will experience reduced loads.
Spall fracture in additive manufactured Ti-6Al-4V
Jones, David Robert; Fensin, Saryu Jindal; Dippo, Olivia; ...
2016-10-07
Here, we present a study on the spall strength of additive manufactured (AM) Ti-6Al-4V. Samples were obtained from two pieces of selective laser melted (SLM, a powder bed fusion technique) Ti-6Al-4V such that the response to dynamic tensile loading could be investigated as a function of the orientation between the build layers and the loading direction. A sample of wrought bar-stock Ti-6Al-4V was also tested to act as a baseline representing the traditionally manufactured material response. A single-stage light gas-gun was used to launch a thin flyer plate into the samples, generating a region of intense tensile stress on amore » plane normal to the impact direction. The rear free surface velocity time history of each sample was recorded with laser-based velocimetry to allow the spall strength to be calculated. The samples were also soft recovered to enable post-mortem characterization of the spall damage evolution. Results showed that when the tensile load was applied normal to the interfaces between the build layers caused by the SLM fabrication process the spall strength was drastically reduced, dropping to 60% of that of the wrought material. However, when loaded parallel to the AM build layer interfaces the spall strength was found to remain at 95% of the wrought control, suggesting that when loading normal to the AM layer interfaces, void nucleation is facilitated more readily due to weaknesses along these boundaries. Quasi-static testing of the same sample orientations revealed a much lower degree of anisotropy, demonstrating the importance of rate-dependent studies for damage evolution in AM materials.« less
Spall fracture in additive manufactured Ti-6Al-4V
NASA Astrophysics Data System (ADS)
Jones, D. R.; Fensin, S. J.; Dippo, O.; Beal, R. A.; Livescu, V.; Martinez, D. T.; Trujillo, C. P.; Florando, J. N.; Kumar, M.; Gray, G. T.
2016-10-01
We present a study on the spall strength of additive manufactured (AM) Ti-6Al-4V. Samples were obtained from two pieces of selective laser melted (SLM, a powder bed fusion technique) Ti-6Al-4V such that the response to dynamic tensile loading could be investigated as a function of the orientation between the build layers and the loading direction. A sample of wrought bar-stock Ti-6Al-4V was also tested to act as a baseline representing the traditionally manufactured material response. A single-stage light gas-gun was used to launch a thin flyer plate into the samples, generating a region of intense tensile stress on a plane normal to the impact direction. The rear free surface velocity time history of each sample was recorded with laser-based velocimetry to allow the spall strength to be calculated. The samples were also soft recovered to enable post-mortem characterization of the spall damage evolution. Results showed that when the tensile load was applied normal to the interfaces between the build layers caused by the SLM fabrication process the spall strength was drastically reduced, dropping to 60% of that of the wrought material. However, when loaded parallel to the AM build layer interfaces the spall strength was found to remain at 95% of the wrought control, suggesting that when loading normal to the AM layer interfaces, void nucleation is facilitated more readily due to weaknesses along these boundaries. Quasi-static testing of the same sample orientations revealed a much lower degree of anisotropy, demonstrating the importance of rate-dependent studies for damage evolution in AM materials.
NASA Astrophysics Data System (ADS)
Xu, Xiaoyu; Chen, Fei; Shen, Shuanghe; Miao, Shiguang; Barlage, Michael; Guo, Wenli; Mahalov, Alex
2018-03-01
The air conditioning (AC) electric loads and their impacts on local weather over Beijing during a 5 day heat wave event in 2010 are investigated by using the Weather Research and Forecasting (WRF) model, in which the Noah land surface model with multiparameterization options (Noah-MP) is coupled to the multilayer Building Effect Parameterization and Building Energy Model (BEP+BEM). Compared to the legacy Noah scheme coupled to BEP+BEM, this modeling system shows a better performance, decreasing the root-mean-square error of 2 m air temperature to 1.9°C for urban stations. The simulated AC electric loads in suburban and rural districts are significantly improved by introducing the urban class-dependent building cooled fraction. Analysis reveals that the observed AC electric loads in each district are characterized by a common double peak at 3 p.m. and at 9 p.m. local standard time, and the incorporation of more realistic AC working schedules helps reproduce the evening peak. Waste heat from AC systems has a smaller effect ( 1°C) on the afternoon 2 m air temperature than the evening one (1.5 2.4°C) if AC systems work for 24 h and vent sensible waste heat into air. Influences of AC systems can only reach up to 400 m above the ground for the evening air temperature and humidity due to a shallower urban boundary layer than daytime. Spatially varying maps of AC working schedules and the ratio of sensible to latent waste heat release are critical for correctly simulating the cooling electric loads and capturing the thermal stratification of urban boundary layer.
Comparison between a typical and a simplified model for blast load-induced structural response
NASA Astrophysics Data System (ADS)
Abd-Elhamed, A.; Mahmoud, S.
2017-02-01
As explosive blasts continue to cause severe damage as well as victims in both civil and military environments. There is a bad need for understanding the behavior of structural elements to such extremely short duration dynamic loads where it is of great concern nowadays. Due to the complexity of the typical blast pressure profile model and in order to reduce the modelling and computational efforts, the simplified triangle model for blast loads profile is used to analyze structural response. This simplified model considers only the positive phase and ignores the suction phase which characterizes the typical one in simulating blast loads. The closed from solution for the equation of motion under blast load as a forcing term modelled either typical or simplified models has been derived. The considered herein two approaches have been compared using the obtained results from simulation response analysis of a building structure under an applied blast load. The computed error in simulating response using the simplified model with respect to the typical one has been computed. In general, both simplified and typical models can perform the dynamic blast-load induced response of building structures. However, the simplified one shows a remarkably different response behavior as compared to the typical one despite its simplicity and the use of only positive phase for simulating the explosive loads. The prediction of the dynamic system responses using the simplified model is not satisfactory due to the obtained larger errors as compared to the system responses obtained using the typical one.
43. BUILDING NO. 454, ORDNANCE FACILITY (BAG CHARGE FILLING PLANT), ...
43. BUILDING NO. 454, ORDNANCE FACILITY (BAG CHARGE FILLING PLANT), DETAIL OF EXPLOSION-PROOF ELECTRICAL SWITCH BOX (SWITCH GEAR INSIDE BOX SUBMERGED IN OIL TO QUENCH SPARKS), SWITCH EQUIPMENT MADE BY GENERAL ELECTRIC. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
Possible Economies in Air-Conditioning by Accepting Temperature Swings.
ERIC Educational Resources Information Center
Loudon, A. G.; Petherbridge, P.
Public building air conditioning systems, which use constant and varying heat and cooling loads, are compared and investigated. Experiments indicated that constant temperature controls based on outside air temperature alone were inefficient. Ventilating a building with outside air and the methods of doing so are cited as being the most economical…
10 CFR 434.517 - HVAC systems and equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... simulation, except that excess capacity provided to meet process loads need not be modeled unless the process... Reference Buildings. The zones in the simulation shall correspond to the zones provided by the controls in... simulation. Table 517.4.1—HVAC System Description for Prototype and Reference Buildings 1,2 HVAC component...
Mass Housing Using GFRG Panels: A Sustainable, Rapid and Affordable Solution
NASA Astrophysics Data System (ADS)
Cherian, Philip; Paul, Shinto; Krishna, S. R. Gouri; Menon, Devdas; Meher Prasad, A.
2017-06-01
This work gives an overview of research and development carried out at IIT Madras, using glass fibre reinforced gypsum (GFRG) panels, to provide an innovative solution for rapid and affordable mass housing. The GFRG panels (124 mm thick), made from recycled industrial waste gypsum (from the fertilizer industry), are prefabricated in 3 m × 12 m sizes with cellular cavities inside, which can be filled with reinforced concrete wherever required and can be used as walls as well as floor slabs. The tests carried out (over the past 12 years) establish the performance of GFRG building systems to resist gravity and lateral loads as a load-bearing system (without beams and columns) in multi-storeyed buildings up to 8-10 storeys, with adequate strength, serviceability, durability and ductility. A two-storeyed four-apartment demonstration building has also been successfully constructed in the IIT Madras campus and presently a mass housing scheme (40 apartment units) using this technology is being demonstrated at Nellore. A structural design code has also been approved by the Bureau of Indian Standards, based on the extensive studies carried out on GFRG building systems.
An Optimization and Assessment on DG adoption in JapanesePrototype Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Nan; Marnay, Chris; Firestone, Ryan
2005-11-30
This research investigates a method of choosing economicallyoptimal DER, expanding on prior studies at the Berkeley Lab using the DERdesign optimization program, the Distributed Energy Resources CustomerAdoption Model (DER-CAM). DER-CAM finds the optimal combination ofinstalled equipment from available DER technologies, given prevailingutility tariffs, site electrical and thermal loads, and a menu ofavailable equipment. It provides a global optimization, albeit idealized,that shows how the site energy load scan be served at minimum cost byselection and operation of on-site generation, heat recovery, andcooling. Five prototype Japanese commercial buildings are examined andDER-CAM applied to select thee conomically optimal DER system for each.The fivemore » building types are office, hospital, hotel, retail, and sportsfacility. Based on the optimization results, energy and emissionreductions are evaluated. Furthermore, a Japan-U.S. comparison study ofpolicy, technology, and utility tariffs relevant to DER installation ispresented. Significant decreases in fuel consumption, carbon emissions,and energy costs were seen in the DER-CAM results. Savings were mostnoticeable in the sports facility, followed by the hospital, hotel, andoffice building.« less
Load Diffusion in Composite and Smart Structures
NASA Technical Reports Server (NTRS)
Horgan, C. O.
2003-01-01
The research carried out here builds on our previous NASA supported research on the general topic of edge effects and load diffusion in composite structures. Further fundamental solid mechanics studies were carried out to provide a basis for assessing the complicated modeling necessary for the multi-functional large scale structures used by NASA. An understanding of the fundamental mechanisms of load diffusion in composite subcomponents is essential in developing primary composite structures. Some specific problems recently considered were those of end effects in smart materials and structures, study of the stress response of pressurized linear piezoelectric cylinders for both static and steady rotating configurations, an analysis of the effect of pre-stressing and pre-polarization on the decay of end effects in piezoelectric solids and investigation of constitutive models for hardening rubber-like materials. Our goal in the study of load diffusion is the development of readily applicable results for the decay lengths in terms of non-dimensional material and geometric parameters. Analytical models of load diffusion behavior are extremely valuable in building an intuitive base for developing refined modeling strategies and assessing results from finite element analyses. The decay behavior of stresses and other field quantities provides a significant aid towards this process. The analysis is also amenable to parameter study with a large parameter space and should be useful in structural tailoring studies. Special purpose analytical models of load diffusion behavior are extremely valuable in building an intuitive base for developing refined modeling strategies and in assessing results from general purpose finite element analyses. For example, a rational basis is needed in choosing where to use three-dimensional to two-dimensional transition finite elements in analyzing stiffened plates and shells. The decay behavior of stresses and other field quantities furnished by this research provides a significant aid towards this element transition issue. A priori knowledge of the extent of boundary-layers induced by edge effects is also useful in determination of the instrumentation location in structural verification tests or in material characterization tests.
Thermal performance of phase change wallboard for residential cooling application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feustel, H.E.; Stetiu, C.
1997-04-01
Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two importantmore » advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the temperature of the room envelope. As heat storage takes place inside the building, where the loads occur, rather than externally, additional transport energy is not required. RADCOOL, a thermal building simulation program based on the finite difference approach, was used to numerically evaluate the latent storage performance of treated wallboard. Extended storage capacity obtained by using double PCM-wallboard is able to keep the room temperatures close to the upper comfort limits without using mechanical cooling. Simulation results for a living room with high internal loads and weather data for Sunnyvale, California, show significant reduction of room air temperature when heat can be stored in PCM-treated wallboards.« less
Comparative study on diagonal equivalent methods of masonry infill panel
NASA Astrophysics Data System (ADS)
Amalia, Aniendhita Rizki; Iranata, Data
2017-06-01
Infrastructure construction in earthquake prone area needs good design process, including modeling a structure in a correct way to reduce damages caused by an earthquake. Earthquakes cause many damages e.g. collapsed buildings that are dangerous. An incorrect modeling in design process certainly affects the structure's ability in responding to load, i.e. an earthquake load, and it needs to be paid attention to in order to reduce damages and fatalities. A correct modeling considers every aspect that affects the strength of a building, including stiffness of resisting lateral loads caused by an earthquake. Most of structural analyses still use open frame method that does not consider the effect of stiffness of masonry panel to the stiffness and strength of the whole structure. Effect of masonry panel is usually not included in design process, but the presence of this panel greatly affects behavior of the building in responding to an earthquake. In worst case scenario, it can even cause the building to collapse as what has been reported after great earthquakes worldwide. Modeling a structure with masonry panel as consideration can be performed by designing the panel as compression brace or shell element. In designing masonry panel as a compression brace, there are fourteen methods popular to be used by structure designers formulated by Saneinejad-Hobbs, Holmes, Stafford-Smith, Mainstones, Mainstones-Weeks, Bazan-Meli, Liauw Kwan, Paulay and Priestley, FEMA 356, Durani Luo, Hendry, Al-Chaar, Papia and Chen-Iranata. Every method has its own equation and parameters to use, therefore the model of every method was compared to results of experimental test to see which one gives closer values. Moreover, those methods also need to be compared to the open frame to see if they can result values within limits. Experimental test that was used in comparing all methods was taken from Mehrabi's research (Fig. 1), which was a prototype of a frame in a structure with 0.5 scale and the ratio of height to width of 1 to 1.5. Load used in the experiment was based on Uniform Building Code (UBC) 1991. Every method compared was calculated first to get equivalent diagonal strut width. The second step was modelling method using structure analysis software as a frame with a diagonal in a linear mode. The linear mode was chosen based on structure analysis commonly used by structure designers. The frame was loaded and for every model, its load and deformation values were identified. The values of load - deformation of every method were compared to those of experimental test specimen by Mehrabi and open frame. From comparative study performed, Holmes' and Bazan-Meli's equations gave results the closest to the experimental test specimen by Mehrabi. Other equations that gave close values within the limit (by comparing it to the open frame) are Saneinejad-Hobbs, Stafford-Smith, Bazan-Meli, Liauw Kwan, Paulay and Priestley, FEMA 356, Durani Luo, Hendry, Papia and Chen-Iranata.
Epting, Jannis; Scheidler, Stefan; Affolter, Annette; Borer, Paul; Mueller, Matthias H; Egli, Lukas; García-Gil, Alejandro; Huggenberger, Peter
2017-10-15
Shallow subsurface thermal regimes in urban areas are increasingly impacted by anthropogenic activities, which include infrastructure development like underground traffic lines as well as industrial and residential subsurface buildings. In combination with the progressive use of shallow geothermal energy systems, this results in the so-called subsurface urban heat island effect. This article emphasizes the importance of considering the thermal impact of subsurface structures, which commonly is underestimated due to missing information and of reliable subsurface temperature data. Based on synthetic heat-transport models different settings of the urban environment were investigated, including: (1) hydraulic gradients and conductivities, which result in different groundwater flow velocities; (2) aquifer properties like groundwater thickness to aquitard and depth to water table; and (3) constructional features, such as building depths and thermal properties of building structures. Our results demonstrate that with rising groundwater flow velocities, the heat-load from building structures increase, whereas down-gradient groundwater temperatures decrease. Thermal impacts on subsurface resources therefore have to be related to the permeability of aquifers and hydraulic boundary conditions. In regard to the urban settings of Basel, Switzerland, flow velocities of around 1 md -1 delineate a marker where either down-gradient temperature deviations or heat-loads into the subsurface are more relevant. Furthermore, no direct thermal influence on groundwater resources should be expected for aquifers with groundwater thicknesses larger 10m and when the distance of the building structure to the groundwater table is higher than around 10m. We demonstrate that measuring temperature changes down-gradient of subsurface structures is insufficient overall to assess thermal impacts, particularly in urban areas. Moreover, in areas which are densely urbanized, and where groundwater flow velocities are low, appropriate measures for assessing thermal impacts should specifically include a quantification of heat-loads into the subsurface which result in a more diffuse thermal contamination of urban groundwater resources. Copyright © 2017 Elsevier B.V. All rights reserved.
Simulation of short-term electric load using an artificial neural network
NASA Astrophysics Data System (ADS)
Ivanin, O. A.
2018-01-01
While solving the task of optimizing operation modes and equipment composition of small energy complexes or other tasks connected with energy planning, it is necessary to have data on energy loads of a consumer. Usually, there is a problem with obtaining real load charts and detailed information about the consumer, because a method of load-charts simulation on the basis of minimal information should be developed. The analysis of work devoted to short-term loads prediction allows choosing artificial neural networks as a most suitable mathematical instrument for solving this problem. The article provides an overview of applied short-term load simulation methods; it describes the advantages of artificial neural networks and offers a neural network structure for electric loads of residential buildings simulation. The results of modeling loads with proposed method and the estimation of its error are presented.
1984-02-01
REQUIREMENT FOR CONSTRUCTION PROJECT: These buildings house electronic equipment, irreplaceable rocket motor design and performance records, a...consists of five subprojects which are to provide modern facilities designed for rocket motor production. These production efficient buildings will...replace facilities which were designed and built in 1930-1942 for artillery shell loading. Four of the sub- projects are for buildings while the fifth
Murphy, Louise U; Cochrane, Thomas A; O'Sullivan, Aisling
2015-03-01
Atmospheric pollutants deposited on impermeable surfaces can be an important source of pollutants to stormwater runoff; however, modelling atmospheric pollutant loads in runoff has rarely been done, because of the challenges and uncertainties in monitoring their contribution. To overcome this, impermeable concrete boards (≈ 1m(2)) were deployed for 11 months in different locations within an urban area (industrial, residential and airside) throughout Christchurch, New Zealand, to capture spatially distributed atmospheric deposition loads in runoff over varying meteorological conditions. Runoff was analysed for total and dissolved Cu, Zn, Pb, and total suspended solids (TSS). Mixed-effect regression models were developed to simulate atmospheric pollutant loads in stormwater runoff. In addition, the models were used to explain the influence of different meteorological characteristics (e.g. antecedent dry days and rain depth) on pollutant build-up and wash-off dynamics. The models predicted approximately 53% to 69% of the variation in pollutant loads and were successful in predicting pollutant-load trends over time which can be useful for general stormwater planning processes. Results from the models illustrated the importance of antecedent dry days on pollutant build-up. Furthermore, results indicated that peak rainfall intensity and rain duration had a significant relationship with TSS and total Pb, whereas, rain depth had a significant relationship with total Cu and total Zn. This suggested that the pollutant speciation phase plays an important role in surface wash-off. Rain intensity and duration had a greater influence when the pollutants were predominantly in their particulate phase. Conversely, rain depth exerted a greater influence when a high fraction of the pollutants were predominantly in their dissolved phase. For all pollutants, the models were represented by a log-arctan relationship for pollutant build-up and a log-log relationship for pollutant wash-off. The modelling approach enables the site-specific relationships between individual pollutants and rainfall characteristics to be investigated. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Dalvi, Ambalika Rajendra
Improving the conditions of schools in many parts of the world is gradually acquiring importance. The Green School movement is an integral part of this effort since it aims at improving indoor environmental conditions. This would in turn, enhance student- learning while minimizing adverse environmental impact through energy efficiency of comfort-related HVAC and lighting systems. This research, which is a part of a larger research project, aims at evaluating different school building designs in Albania in terms of energy use and indoor thermal comfort, and identify energy efficient options of existing schools. We start by identifying three different climate zones in Albania; Coastal (Durres), Hill/Pre-mountainous (Tirana), mountainous (Korca). Next, two prototypical school building designs are identified from the existing stock. Numerous scenarios are then identified for analysis which consists of combinations of climate zone, building type, building orientation, building upgrade levels, presence of renewable energy systems (solar photovoltaic and solar water heater). The existing building layouts, initially outlined in CAD software and then imported into a detailed building energy software program (eQuest) to perform annual simulations for all scenarios. The research also predicted indoor thermal comfort conditions of the various scenarios on the premise that windows could be opened to provide natural ventilation cooling when appropriate. This study also estimated the energy generated from solar photovoltaic systems and solar water heater systems when placed on the available roof area to determine the extent to which they are able to meet the required electric loads (plug and lights) and building heating loads respectively. The results showed that there is adequate indoor comfort without the need for mechanical cooling for the three climate zones, and that only heating is needed during the winter months.
Third of three panoramic views of North Base as seen ...
Third of three panoramic views of North Base as seen from top of Building 4500, Control Tower. View looks west (268°) at ancillary structures surrounding Building 4505. In immediate foreground is Building 4499 Loading Ramp. To the far upper left is Building 4497 Guard House, adjacent to Building 4496 Security Facility. At the extreme right of the view is the chimney and western corner of Building 4505 to which is attached a large light-colored wing used as offices and workspaces; to the immediate southwest of this wing stands Building 4498 Supply Warehouse. In the background, just above Building 4498 in view, stands Building 4494 Cafeteria. The round drum to the right of Building 4494 is Building 4503, a 500,000 gallon water tank which supplies the firefighting system; to the immediate right of the tank is Building 4504 Deluge Water Pumping Station which contains large pumps for firefighting. Just visible above the water tank is Building 4493 Gymnasium. - Edwards Air Force Base, North Base, North Base Road, Boron, Kern County, CA
Analysis of Wind Forces on Roof-Top Solar Panel
NASA Astrophysics Data System (ADS)
Panta, Yogendra; Kudav, Ganesh
2011-03-01
Structural loads on solar panels include forces due to high wind, gravity, thermal expansion, and earthquakes. International Building Code (IBC) and the American Society of Civil Engineers are two commonly used approaches in solar industries to address wind loads. Minimum Design Loads for Buildings and Other Structures (ASCE 7-02) can be used to calculate wind uplift loads on roof-mounted solar panels. The present study is primarily focused on 2D and 3D modeling with steady, and turbulent flow over an inclined solar panel on the flat based roof to predict the wind forces for designing wind management system. For the numerical simulation, 3-D incompressible flow with the standard k- ɛ was adopted and commercial CFD software ANSYS FLUENT was used. Results were then validated with wind tunnel experiments with a good agreement. Solar panels with various aspect ratios for various high wind speeds and angle of attacks were modeled and simulated in order to predict the wind loads in various scenarios. The present study concluded to reduce the strong wind uplift by designing a guide plate or a deflector before the panel. Acknowledgments to Northern States Metal Inc., OH (GK & YP) and School of Graduate Studies of YSU for RP & URC 2009-2010 (YP).
Late developments in the field of heat recovery
NASA Astrophysics Data System (ADS)
McFarlan, A. I.
Developments to reduce the first cost and operating expense of large building air conditioning systems, with emphasis on heat transfer are described. The 3 pipe wide range coils dissipate part of the summer cooling load directly to the outside of the building without passing thru the water chillers. Tank circuits to automatically cycle water thru storage tanks can reduce the refrigeration load about 35% during the peak day period. Means to produce above 48.9 C hot water economically for winter heating and summer dissipation of internal heat are described. A heat balance is maintained automatically to remove only the excess winter heat beyond that which can be usefully recycled or stored.
Performance of nutrient-loaded red oak and white oak seedlings on mine lands in southern Indiana
K. Francis Salifu; Douglass F. Jacobs; Zonda K. D. Birge
2008-01-01
Exponential nutrient loading was used to build nutrient reserves in northern red oak (Quercus rubra) and white oak (Q. alba) seedlings during standard bareroot nursery culture at the Vallonia State Nursery, Indiana. Nursery grown seedlings were outplanted the following year onto a mine reclamation site in southern Indiana to...
Technology Solutions Case Study: Hygrothermal Performance of a Double-Stud Cellulose Wall
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2015-06-01
Moisture problems within the building shell can be caused by a number of factors including excess interior moisture that is transported into the wall through air leakage and vapor drive, bulk water intrusion from leaks and wind-driven rain, capillary action from concrete to wood connections, and through wetted building materials such as siding wetted from rain splash back. With the increasing thickness of walls, moisture issues could increase. Several builders have successfully used “double-wall” systems to more practically achieve higher R-values in thicker framed walls. A double wall typically consists of a load-bearing external frame wall constructed with 2 ×more » 4 framing at 16 in. on center using conventional methods. After the building is enclosed, an additional frame wall is constructed several inches inside the load-bearing wall. Several researchers have used moisture modeling software to conduct extensive analysis of these assemblies; however, little field research has been conducted to validate the results. In this project, the Building America research team Consortium for Advanced Residential Buildings monitored a double-stud assembly in climate zone 5A to determine the accu¬racy of moisture modeling and make recommendations to ensure durable and efficient assemblies.« less
NASA Technical Reports Server (NTRS)
Holland, D. B.; Virgin, L. N.; Belvin, W. K.
2003-01-01
This paper presents a parameter study of the effect of boom axial loading on the global dynamics of a 2-meter solar sail scale model. The experimental model used is meant for building expertise in finite element analysis and experimental execution, not as a predecessor to any planned flight mission or particular design concept. The results here are to demonstrate the ability to predict and measure structural dynamics and mode shapes in the presence of axial loading.
Evaluation of Force Transfer Around Openings - Experimental and Analytical Studies
Borjen Yeh; Tom Skaggs; Frank Lam; Minghao Li; Douglas Rammer; James Wacker
2011-01-01
Wood structural panel (WSP) sheathed shear walls and diaphragms are the primary lateral-load-resistingelements in wood-frame construction. The historical performance of light-frame structures in North America is very good due, in part, to model building codes that are designed to safeguard life safety. These model building codes have spawned continual improvement and...
Samuel V. Glass; Stanley D. Gatland II; Kohta Ueno; Christopher J. Schumacher
2017-01-01
ASHRAE Standard 160, Criteria for Moisture-Control Design Analysis in Buildings, was published in 2009. The standard sets criteria for moisture design loads, hygrothermal analysis methods, and satisfactory moisture performance of the building envelope. One of the evaluation criteria specifies conditions necessary to avoid mold growth. The current standard requires that...
Code of Federal Regulations, 2012 CFR
2012-04-01
... Design Specification for Wood Construction—1991. American National Standards Institute, 11 West 42nd... Street, New York, NY 10017. ASCE 7-88 Minimum Design Loads for Buildings and Other Structures (Formerly... Institute Building, College Park, MD 20740 Telephone (301) 277-4258. MSI-1-81 Thickness Design—Asphalt...