Sample records for gage circle hooks

  1. The influence of hook type, angler experience, and fish size on injury rates and the duration of capture in an Alaskan catch-and-release rainbow trout fishery

    USGS Publications Warehouse

    Meka, Julie M.

    2004-01-01

    Owing to concerns about the high incidence of past hooking injuries in Alagnak River rainbow trout Oncorhynchus mykiss, fish were captured with spin- and fly-fishing gear with barbed and barbless circle and "J" hooks to determine gear types contributing to injury. Landing and hook removal times were measured for a portion of fish captured, and the anatomical hooking location, hooking scar locations, bleeding intensity, angler experience, and fish size were recorded for all captured fish. Approximately 62% of fish captured experienced at least one new hooking injury, and 29% of fish had at least one past hooking injury. Small fish sustained higher new injury and bleeding rates, but large fish had higher past injury rates. Injury rates were higher for barbed J hooks, barbed J hooks took longer to remove, and fish caught by spin-fishing were injured more frequently than fish caught by fly-fishing. Fewer fly-fishing-caught fish were injured using circle hooks, and circle hooks tended to hook fish in only one location, generally in the jaw. Barbed J hooks were more efficient at landing fish, and J hooks were more efficient at landing fish than circle hooks. Novice anglers injured proportionally more fish than experienced anglers, primarily during hook removal. Landing time was positively correlated with fish size, and experienced anglers took longer to land fish than novices because they captured larger fish. These results suggest that a reduction in hooking injuries may be achieved by using circle hooks as an alternative to J hooks and barbless J hooks to reduce injury and handling time, yet catch efficiency for both methods would be reduced. Although fish captured with barbless J hooks and circle hooks had fewer injuries, it is important to note that each hook type also caused significant injury, and angler education is recommended to promote proper hook removal techniques.

  2. Alfred P. Gage and the Introductory Physics Laboratory

    NASA Astrophysics Data System (ADS)

    Greenslade, Thomas B.

    2016-03-01

    This article is about a late 19th-century teacher of secondary school physics. I was originally interested in the apparatus that he sold. This led me to the physics books that he wrote, and these took me to his unusual ideas about ways to use laboratory time to introduce students to the phenomena of physics. More than 100 years later educational ideas have now come full circle, and it is time to bring Gage and his texts and ideas to 21st-century physics teachers.

  3. Internally Mounting Strain Gages

    NASA Technical Reports Server (NTRS)

    Jett, J. R., Jr.

    1984-01-01

    Technique for mounting strain gages inside bolt or cylinder simultaneously inserts gage, attached dowel segment, and length of expandable tubing. Expandable tubing holds gage in place while adhesive cures, assuring even distribution of pressure on gage and area gaged.

  4. Strain Gage

    NASA Technical Reports Server (NTRS)

    1995-01-01

    HITEC Corporation developed a strain gage application for DanteII, a mobile robot developed for NASA. The gage measured bending forces on the robot's legs and warned human controllers when acceptable forces were exceeded. HITEC further developed the technology for strain gage services in creating transducers out of "Indy" racing car suspension pushrods, NASCAR suspension components and components used in motion control.

  5. Lunar crane hook

    NASA Technical Reports Server (NTRS)

    Cash, John Wilson, III; Cone, Alan E.; Garolera, Frank J.; German, David; Lindabury, David Peter; Luckado, Marshall Cleveland; Murphey, Craig; Rowell, John Bryan; Wilkinson, Brad

    1988-01-01

    The base and ball hook system is an attachment that is designed to be used on the lunar surface as an improved alternative to the common crane hook and eye system. The design proposed uses an omni-directional ball hook and base to overcome the design problems associated with a conventional crane hook. The base and ball hook is not sensitive to cable twist which would render a robotic lunar crane useless since there is little atmospheric resistance to dampen the motion of an oscillating member. The symmetric characteristics of the ball hook and base eliminates manual placement of the ball hook into the base; commonly associated with the typical hook and eye stem. The major advantage of the base and ball hook system is it's ease of couple and uncouple modes that are advantages during unmanned robotic lunar missions.

  6. GAGES-II: Geospatial Attributes of Gages for Evaluating Streamflow

    USGS Publications Warehouse

    Falcone, James A.

    2011-01-01

    This dataset, termed "GAGES II", an acronym for Geospatial Attributes of Gages for Evaluating Streamflow, version II, provides geospatial data and classifications for 9,322 stream gages maintained by the U.S. Geological Survey (USGS). It is an update to the original GAGES, which was published as a Data Paper on the journal Ecology's website (Falcone and others, 2010b) in 2010. The GAGES II dataset consists of gages which have had either 20+ complete years (not necessarily continuous) of discharge record since 1950, or are currently active, as of water year 2009, and whose watersheds lie within the United States, including Alaska, Hawaii, and Puerto Rico. Reference gages were identified based on indicators that they were the least-disturbed watersheds within the framework of broad regions, based on 12 major ecoregions across the United States. Of the 9,322 total sites, 2,057 are classified as reference, and 7,265 as non-reference. Of the 2,057 reference sites, 1,633 have (through 2009) 20+ years of record since 1950. Some sites have very long flow records: a number of gages have been in continuous service since 1900 (at least), and have 110 years of complete record (1900-2009) to date. The geospatial data include several hundred watershed characteristics compiled from national data sources, including environmental features (e.g. climate – including historical precipitation, geology, soils, topography) and anthropogenic influences (e.g. land use, road density, presence of dams, canals, or power plants). The dataset also includes comments from local USGS Water Science Centers, based on Annual Data Reports, pertinent to hydrologic modifications and influences. The data posted also include watershed boundaries in GIS format. This overall dataset is different in nature to the USGS Hydro-Climatic Data Network (HCDN; Slack and Landwehr 1992), whose data evaluation ended with water year 1988. The HCDN identifies stream gages which at some point in their history had

  7. Coverage of the Phineas Gage Story in Introductory Psychology Textbooks: Was Gage No Longer Gage?

    ERIC Educational Resources Information Center

    Griggs, Richard A.

    2015-01-01

    Most introductory textbooks discuss the story of Phineas Gage and his terrible accident in which he survived a three-and-a-half-foot-long tamping iron that weighed 13¼ pounds exploding through his head. Twenty-three current introductory textbooks were analyzed for the accuracy of their coverage of Gage's subsequent (post-accident) history and…

  8. Levels at gaging stations

    USGS Publications Warehouse

    Kenney, Terry A.

    2010-01-01

    Operational procedures at U.S. Geological Survey gaging stations include periodic leveling checks to ensure that gages are accurately set to the established gage datum. Differential leveling techniques are used to determine elevations for reference marks, reference points, all gages, and the water surface. The techniques presented in this manual provide guidance on instruments and methods that ensure gaging-station levels are run to both a high precision and accuracy. Levels are run at gaging stations whenever differences in gage readings are unresolved, stations may have been damaged, or according to a pre-determined frequency. Engineer's levels, both optical levels and electronic digital levels, are commonly used for gaging-station levels. Collimation tests should be run at least once a week for any week that levels are run, and the absolute value of the collimation error cannot exceed 0.003 foot/100 feet (ft). An acceptable set of gaging-station levels consists of a minimum of two foresights, each from a different instrument height, taken on at least two independent reference marks, all reference points, all gages, and the water surface. The initial instrument height is determined from another independent reference mark, known as the origin, or base reference mark. The absolute value of the closure error of a leveling circuit must be less than or equal to ft, where n is the total number of instrument setups, and may not exceed |0.015| ft regardless of the number of instrument setups. Closure error for a leveling circuit is distributed by instrument setup and adjusted elevations are determined. Side shots in a level circuit are assessed by examining the differences between the adjusted first and second elevations for each objective point in the circuit. The absolute value of these differences must be less than or equal to 0.005 ft. Final elevations for objective points are determined by averaging the valid adjusted first and second elevations. If final elevations

  9. Levels at streamflow gaging stations

    USGS Publications Warehouse

    Kennedy, E.J.

    1988-01-01

    This manual establishes the surveying procedures for setting gages at a streamflow gaging station to datum and for checking them periodically for errors caused by vertical movement of the gage-supporting structures. The surveying terms and concepts used are explained; and the details of testing, adjusting, and operating the instruments are outlined. Notekeeping, adjusting level circuits, checking gages, summarizing results, locating the nearest National Geodetic Vertical Datum of 1929 bench mark, and relating the gage datum to the national datum are described.

  10. Three-in-one gage

    NASA Technical Reports Server (NTRS)

    Garecht, D. M.

    1988-01-01

    The Three-in-One Gage is a three way gage designed to measure pressure, temperature, and displacement at the same port continuously. The Two-in-One Gage is a two way gage designed to measure pressure and temperature in the same port continuously. The Two-in-One is an adaptation of the Three-in-One to incorporate dual seals, however, without the proximity sensor. The Three-in-One is assembled using two Type K thermocouples, 1 Kulite Pressure Transducer, and one Kaman Proximity Displacement Sensor. Tests of performance were completed.

  11. Levels at streamflow gaging stations

    USGS Publications Warehouse

    Kennedy, E.J.

    1990-01-01

    This manual establishes the surveying procedures for (1) setting gages at a streamflow gaging station to datum and (2) checking the gages periodically for errors caused by vertical movement of the structures that support them. Surveying terms and concepts are explained, and procedures for testing, adjusting, and operating the instruments are described in detail. Notekeeping, adjusting level circuits, checking gages, summarizing results, locating the nearest National Geodetic Vertical Datum of 1929 bench mark, and relating the gage datum to the national datum are also described.

  12. Hooke's figurations: a figural drawing attributed to Robert Hooke.

    PubMed

    Hunter, Matthew C

    2010-09-20

    The experimental philosopher Robert Hooke (1635-1703) is known to have apprenticed to the leading painter Peter Lely on his first arrival in London in the late 1640s. Yet the relevance of Hooke's artistic training to his mature draughtsmanship and identity has remained unclear. Shedding light on that larger interpretive problem, this article argues for the attribution to Hooke of a figural drawing now in Tate Britain (T10678). This attributed drawing is especially interesting because it depicts human subjects and bears Hooke's name functioning as an artistic signature, both highly unusual features for his draughtsmanship. From evidence of how this drawing was collected and physically placed alongside images by leading artists in the early eighteenth century, I suggest how it can offer new insight into the reception of Hooke and his graphic work in the early Enlightenment.

  13. Meanest foundations and nobler superstructures: Hooke, Newton and the "compounding of the celestiall motions of the planets

    NASA Astrophysics Data System (ADS)

    Gal, Ofer

    This book is a historical-epistemological study of one the most consequential idea of early modern celestial mechanics: Robert Hooke's proposal to "compoun[d] the celestial motions of the planets of a direct motion by the tangent & an attractive motion towards a central body," a proposal which Isaac Newton adopted and realized in his Principia. Hooke's Programme was revolutionary both cosmologically and mathematically. It presented "the celestial motions," the proverbial symbol of stability and immutability, as a process of continuous change, and prescribed only parameters of rectilinear motions and rectilinear attractions for calculating their closed curved orbits. Yet the traces of Hooke's construction of his Programme for the heavens lead through his investigations in such earthly disciplines as microscopy, practical optics and horology, and the mathematical tools developed by Newton to accomplish it appear no less local and goal-oriented than Hooke's lenses and springs. This transgression of the boundaries between the theoretical, experimental and technological realms is reminiscent of Hooke's own free excursions in and out of the circles occupied by gentlemen-philosophers, university mathematicians, instrument makers, technicians and servants. It presents an opportunity to examine the social and epistemological distinctions, relations and hierarchies between those realms and their inhabitants, and compels a critical assessment of the philosophical categories they embody.

  14. Biomechanical analysis of clavicle hook plate implantation with different hook angles in the acromioclavicular joint.

    PubMed

    Hung, Li-Kun; Su, Kuo-Chih; Lu, Wen-Hsien; Lee, Cheng-Hung

    2017-08-01

    A clavicle hook plate is a simple and effective method for treating acromioclavicular dislocation and distal clavicle fractures. However, subacromial osteolysis and peri-implant fractures are complicated for surgeons to manage. This study uses finite element analysis (FEA) to investigate the post-implantation biomechanics of clavicle hook plates with different hook angles. This FEA study constructed a model with a clavicle, acromion, clavicle hook plate, and screws to simulate the implantation of clavicle hook plates at different hook angles (90°, 95°, 100°, 105°, and 110°) for treating acromioclavicular joint dislocations. This study investigated the biomechanics of the acromion, clavicle, hook plate, and screws. A smaller hook angle increases the stress on the middle third of the clavicle. A larger hook angle increases the force exerted by the clavicle hook plate on the acromion. The screw at the most medial position on the plate generated the highest stress. The highest stress on the implanted clavicle hook plate was on the turning corner of the hook. A clavicle hook plate with different hook angles may induce different biomechanical behaviors in the clavicle and acromion. Orthopedic surgeons must select a suitable clavicle hook plate based on the anatomical structure of each patient.

  15. Strain gage system evaluation program

    NASA Technical Reports Server (NTRS)

    Dolleris, G. W.; Mazur, H. J.; Kokoszka, E., Jr.

    1978-01-01

    A program was conducted to determine the reliability of various strain gage systems when applied to rotating compressor blades in an aircraft gas turbine engine. A survey of current technology strain gage systems was conducted to provide a basis for selecting candidate systems for evaluation. Testing and evaluation was conducted in an F 100 engine. Sixty strain gage systems of seven different designs were installed on the first and third stages of an F 100 engine fan. Nineteen strain gage failures occurred during 62 hours of engine operation, for a survival rate of 68 percent. Of the failures, 16 occurred at blade-to-disk leadwire jumps (84 percent), two at a leadwire splice (11 percent), and one at a gage splice (5 percent). Effects of erosion, temperature, G-loading, and stress levels are discussed. Results of a post-test analysis of the individual components of each strain gage system are presented.

  16. High-Temperature Adhesive Strain Gage Developed

    NASA Technical Reports Server (NTRS)

    Pereira, J. Michael; Roberts, Gary D.

    1997-01-01

    Researchers at the NASA Lewis Research Center have developed a unique strain gage and adhesive system for measuring the mechanical properties of polymers and polymer composites at elevated temperatures. This system overcomes some of the problems encountered in using commercial strain gages and adhesives. For example, typical commercial strain gage adhesives require a postcure at temperatures substantially higher than the maximum test temperature. The exposure of the specimen to this temperature may affect subsequent results, and in some cases may be higher than the glass-transition temperature of the polymer. In addition, although typical commercial strain gages can be used for short times at temperatures up to 370 C, their long-term use is limited to 230 C. This precludes their use for testing some high-temperature polyimides near their maximum temperature capability. Lewis' strain gage and adhesive system consists of a nonencapsulated, unbacked gage grid that is bonded directly to the polymer after the specimen has been cured but prior to the normal postcure cycle. The gage is applied with an adhesive specially formulated to cure under the specimen postcure conditions. Special handling, mounting, and electrical connection procedures were developed, and a fixture was designed to calibrate each strain gage after it was applied to a specimen. A variety of tests was conducted to determine the performance characteristics of the gages at elevated temperatures on PMR-15 neat resin and titanium specimens. For these tests, which included static tension, thermal exposure, and creep tests, the gage and adhesive system performed within normal strain gage specifications at 315 C. An example of the performance characteristics of the gage can be seen in the figure, which compares the strain gage measurement on a polyimide specimen at 315 C with an extensometer measurement.

  17. Thin film strain gage development program

    NASA Technical Reports Server (NTRS)

    Grant, H. P.; Przybyszewski, J. S.; Anderson, W. L.; Claing, R. G.

    1983-01-01

    Sputtered thin-film dynamic strain gages of 2 millimeter (0.08 in) gage length and 10 micrometer (0.0004 in) thickness were fabricated on turbojet engine blades and tested in a simulated compressor environment. Four designs were developed, two for service to 600 K (600 F) and two for service to 900 K (1200 F). The program included a detailed study of guidelines for formulating strain-gage alloys to achieve superior dynamic and static gage performance. The tests included gage factor, fatigue, temperature cycling, spin to 100,000 G, and erosion. Since the installations are 30 times thinner than conventional wire strain gage installations, and any alteration of the aerodynamic, thermal, or structural performance of the blade is correspondingly reduced, dynamic strain measurement accuracy higher than that attained with conventional gages is expected. The low profile and good adherence of the thin film elements is expected to result in improved durability over conventional gage elements in engine tests.

  18. Ultrasonic Bolt Gage

    NASA Technical Reports Server (NTRS)

    Gleman, Stuart M. (Inventor); Rowe, Geoffrey K. (Inventor)

    1999-01-01

    An ultrasonic bolt gage is described which uses a crosscorrelation algorithm to determine a tension applied to a fastener, such as a bolt. The cross-correlation analysis is preferably performed using a processor operating on a series of captured ultrasonic echo waveforms. The ultrasonic bolt gage is further described as using the captured ultrasonic echo waveforms to perform additional modes of analysis, such as feature recognition. Multiple tension data outputs, therefore, can be obtained from a single data acquisition for increased measurement reliability. In addition, one embodiment of the gage has been described as multi-channel, having a multiplexer for performing a tension analysis on one of a plurality of bolts.

  19. 49 CFR 213.53 - Gage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Gage. 213.53 Section 213.53 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Geometry § 213.53 Gage. (a) Gage is measured between the heads of the...

  20. 49 CFR 213.53 - Gage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Gage. 213.53 Section 213.53 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Geometry § 213.53 Gage. (a) Gage is measured between the heads of the...

  1. Three-dimensional scapular dyskinesis in hook-plated acromioclavicular dislocation including hook motion.

    PubMed

    Kim, Eugene; Lee, Seunghee; Jeong, Hwa-Jae; Park, Jai Hyung; Park, Se-Jin; Lee, Jaewook; Kim, Woosub; Park, Hee Jin; Lee, So Yeon; Murase, Tsuyoshi; Sugamoto, Kazuomi; Ikemoto, Sumika

    2018-06-01

    The purpose of this study is to analyze the 3-dimensional scapular dyskinesis and the kinematics of a hook plate relative to the acromion after hook-plated acromioclavicular dislocation in vivo. Reported complications of acromioclavicular reduction using a hook plate include subacromial erosion and impingement. However, there are few reports of the 3-dimensional kinematics of the hook and scapula after the aforementioned surgical procedure. We studied 15 cases of acromioclavicular dislocation treated with a hook plate and 15 contralateral normal shoulders using computed tomography in the neutral and full forward flexion positions. Three-dimensional motion of the scapula relative to the thorax during arm elevation was analyzed using a computer simulation program. We also measured the distance from the tip of the hook plate to the greater tuberosity, as well as the angular motion of the plate tip in the subacromial space. Decreased posterior tilting (22° ± 10° vs 31° ± 8°) in the sagittal plane and increased external rotation (19° ± 9° vs 7° ± 5°) in the axial plane were evident in the affected shoulders. The mean values of translation of the hook plate and angular motion against the acromion were 4.0 ± 1.6 mm and 15° ± 8°, respectively. The minimum value of the distance from the hook plate to the humeral head tuberosity was 6.9 mm during arm elevation. Acromioclavicular reduction using a hook plate may cause scapular dyskinesis. Translational and angular motion of the hook plate against the acromion could lead to subacromial erosion. However, the hook does not seem to impinge directly on the humeral head. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. Zero-gravity quantity gaging system

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The Zero-Gravity Quantity Gaging System program is a technology development effort funded by NASA-LeRC and contracted by NASA-JSC to develop and evaluate zero-gravity quantity gaging system concepts suitable for application to large, on-orbit cryogenic oxygen and hydrogen tankage. The contract effective date was 28 May 1985. During performance of the program, 18 potential quantity gaging approaches were investigated for their merit and suitability for gaging two-phase cryogenic oxygen and hydrogen in zero-gravity conditions. These approaches were subjected to a comprehensive trade study and selection process, which found that the RF modal quantity gaging approach was the most suitable for both liquid oxygen and liquid hydrogen applications. This selection was made with NASA-JSC concurrence.

  3. Development of high temperature strain gages

    NASA Technical Reports Server (NTRS)

    Lemcoe, M. M.

    1973-01-01

    High temperature electric resistance wire strain gages were developed and evaluated for use at temperatures exceeding 922 K (1200 F). A special high temperature strain gage alloy (Fe-25Cr-7.5A1), designated BCL-3, was used to fabricate the gages. Pertinent gage characteristics were determined at temperatures up to 1255 K (1800 F). The results of the evaluation were reported in graphical and tabular form. It was concluded that the gages will perform satisfactorily at temperatures to at least 1089 K (1500 F) for at least one hour.

  4. RF Modal Quantity Gaging

    NASA Technical Reports Server (NTRS)

    Vanleuven, K.

    1989-01-01

    The primary objective is to provide a concept of a radio frequency (RF) modal resonance technique which is being investigated as a method for gaging the quantities of subcritical cryogenic propellants in metallic tanks. Of special interest are the potential applications of the technique to microgravity propellant gaging situations. The results of concept testing using cryogenic oxygen, hydrogen, and nitrogen, as well as paraffin simulations of microgravity fluid orientations, are reported. These test results were positive and showed that the gaging concept was viable.

  5. The Development of Electrical Strain Gages

    NASA Technical Reports Server (NTRS)

    De Forest, A V; Leaderman, H

    1940-01-01

    The design, construction, and properties of an electrical-resistance strain gage consisting of fine wires molded in a laminated plastic are described. The properties of such gages are discussed and also the problems of molding of wires in plastic materials, temperature compensation, and cementing and removal of the gages. Further work to be carried out on the strain gage, together with instrument problems, is discussed.

  6. High-Temperature, Thin-Film Strain Gages Improved

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Conventional resistance strain gage technology uses "bonded" strain gages. These foil or wire gages are bonded onto the surface of the test article with glue, ceramic cements, or flame-sprayed ceramics. These bonding agents can, in some instances, limit both the degree of strain transmission from the test structure to the gage and the maximum working temperature of the gage. Also, the bulky, bonded gage normally disrupts aerodynamic gas flow on the surface of the test structure because of its intrusive character. To respond to the urgent needs in aeronautic and aerospace research where stress and temperature gradients are high, aerodynamic effects need to be minimized, and higher operational temperatures are required, the NASA Lewis Research Center developed a thin film strain gage. This gage, a vacuum-deposited thin film formed directly on the surface of a test structure, operates at much higher temperatures than commercially available gages do and with minimal disruption of the aerodynamic flow. The gage uses an alloy, palladium-13 wt % chromium (hereafter, PdCr), which was developed by United Technologies Research Center under a NASA contract. PdCr is structurally stable and oxidation resistant up to at least 1100 C (2000 F); its temperature-induced resistance change is linear, repeatable, and not sensitive to the rates of heating and cooling. An early strain gage, which was made of 25-micrometer-diameter PdCr wire and demonstrated to be useable to 800 C, won an R&D 100 award in 1991. By further improving the purity of the material and by developing gage fabrication techniques that use sputter-deposition, photolithography patterning, and chemical etching, we have made an 8- to 10-m PdCr thin-film strain gage that can measure dynamic and static strain to at least 1100 C. For static strain measurements, a 5-m-thick Pt element serves as a temperature compensator to further minimize the temperature effect of the gage. These thin-film gages provide the advantage of

  7. Comparison of torsional stability of 2 types of split crimpable surgical hooks with soldered brass surgical hooks.

    PubMed

    O'Bannon, Shawn P; Dunn, William J; Lenk, Jason S

    2006-10-01

    The purpose of this in-vitro study was to compare the torsional stability of split crimpable surgical hooks and soldered brass surgical hooks on a rectangular stabilizing archwire. Coated split crimpable hooks (Never-Slip Grip, TP Orthodontics, LaPorte, Ind), ribbed crimpable hooks (TP Orthodontics), and .032-in brass soldered hooks/notched electrodes (Ormco/Sybron Dental Specialties, Orange, Calif) were attached to a 0.019 x 0.025-in stainless steel archwire. The archwire/hook attachment assembly was secured into a dual contact jig and statically mounted to the base of a universal testing machine. The hooks were engaged by a wire loop attached to the upper load cell of the machine, which pulled the wire until the hook was torsionally displaced from the archwire. The mean forces, measured in newtons (N), required to dislodge the hooks were as follows: soldered brass surgical hooks (51.3 +/- 5.2 N), coated split crimpable hooks (49.9 +/- 6.6 N), and ribbed split crimpable hooks (31.3 +/- 5.4 N). Data were analyzed with 1-way ANOVA and Tukey HSD post-hoc tests at alpha = .05. Ribbed split crimpable hooks provided significantly less resistance to torsional displacement than the other types of hooks (P <001). There was no difference between coated split crimpable hooks and soldered brass surgical hooks (P >05). Under the conditions of this study, the results suggest that soldered brass surgical hooks and coated split crimpable hook attachments provide more stability to torsional dislodgement from a rectangular stabilizing archwire than ribbed split crimpable hooks.

  8. Inexpensive Bolt-Load Gage

    NASA Technical Reports Server (NTRS)

    Long, M. J.

    1983-01-01

    "Built-in" gage determines whether large bolt or stud has been torqued to desired load and provides for continuous inspection to ensure proper load is being maintained. Gage detects longitudinal stress/strain bolt; requires no electronic or sonic test equipment.

  9. Palladium-chromium static strain gages for high temperatures

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen

    1992-01-01

    An electrical resistance strain gage that can provide accurate static strain measurement to a temperature of 1500 F or above is being developed both in fine wire and thin film forms. The gage is designed to be temperature compensated on any substrate material. It has a dual element: the gage element is a special alloy, palladium-13wt percent chromium (PdCr), and the compensator element is platinum (Pt). Earlier results of a PdCr based wire gage indicated that the apparent strain of this gage can be minimized and the repeatability of the apparent strain can be improved by prestabilizing the gage on the substrate for a long period of time. However, this kind of prestabilization is not practical in many applications and therefore the development of a wire gage which is prestabilized before installation on the substrate is desirable. This paper will present our recent progress in the development of a prestabilized wire gage which can provide meaningful strain data for the first thermal cycle. A weldable PdCr gage is also being developed for field testing where conventional flame-spraying installation can not be applied. This weldable gage is narrower than a previously reported gage, thereby allowing the gage to be more resistant to buckling under compressive loads. Some preliminary results of a prestabilized wire gage flame-sprayed directly on IN100, an engine material, and a weldable gage spot-welded on IN100 and SCS-6/(beta)21-S Titanium Matrix Composite (TMC), a National Aero-Space Plane (NASP) structure material, will be reported. Progress on the development of a weldable thin film gage will also be addressed. The measurement technique and procedures and the lead wire effect will be discussed.

  10. Getting Hooked on Physics!

    ERIC Educational Resources Information Center

    McHugh, M.; McCauley, V.

    2016-01-01

    A number of papers in this journal have dealt with the idea of using hooks in physics instruction. A hook, as the name suggests, engages students in learning by triggering their attention and interest. Hooks can be any type of pedagogical approach--a question, a demonstration, a puzzle or video. They are generally short and center on the most…

  11. Role of the Dc domain of the bacterial hook protein FlgE in hook assembly and function

    PubMed Central

    Moriya, Nao; Minamino, Tohru; Ferris, Hedda U.; Morimoto, Yusuke V.; Ashihara, Masamichi; Kato, Takayuki; Namba, Keiichi

    2013-01-01

    The bacterial flagellar hook acts as a universal joint to smoothly transmit torque produced by the motor to the filament. The hook protein FlgE assembles into a 55 nm tubular structure with the help of the hook cap (FlgD). FlgE consists of four domains, D0, Dc, D1 and D2, arranged from the inner to the outer part of the tubular structure of the hook. The Dc domain contributes to the structural stability of the hook, but it is unclear how this Dc domain is responsible for the universal joint mechanism. Here, we carried out a deletion analysis of the FlgE Dc domain. FlgEΔ4/5 with deletion of residues 30 to 49 was not secreted into the culture media. FlgEΔ5 and FlgEΔ6 with deletions of residues 40 to 49 and 50 to 59, respectively, still formed hooks, allowing the export apparatus to export the hook-filament junction proteins FlgK and FlgL and flagellin FliC. However, these deletions inhibited the replacement of the FlgD hook cap by FlgK at the hook tip, thereby abolishing filament formation. Deletion of residues 50 to 59 significantly affected hook morphology. These results suggest that the Dc domain is responsible not only for hook assembly but also for FlgE export, the interaction with FlgK, and the polymorphic supercoiling mechanism of the hook. PMID:27493542

  12. Elevated temperature strain gages

    NASA Technical Reports Server (NTRS)

    Brittain, J. O.; Geslin, D.; Lei, J. F.

    1985-01-01

    Materials were evaluated that could be used in manufacturing electrical resistance strain gages for static strain measurements at temperatures at or above 1273 K. Strain gage materials must have a characteristic response to strain, temperature and time that is reproducible or that varies in a predictable manner within specified limits. Several metallic alloys were evaluated, as well as a series of transition metal carbides, nitrides and silicides.

  13. Stress analyses of B-52 pylon hooks

    NASA Technical Reports Server (NTRS)

    Ko, W. L.; Schuster, L. S.

    1985-01-01

    The NASTRAN finite element computer program was used in the two dimensional stress analysis of B-52 carrier aircraft pylon hooks: (1) old rear hook (which failed), (2) new rear hook (improved geometry), (3) new DAST rear hook (derated geometry), and (4) front hook. NASTRAN model meshes were generated by the aid of PATRAN-G computer program. Brittle limit loads for all the four hooks were established. The critical stress level calculated from NASTRAN agrees reasonably well with the values predicted from the fracture mechanics for the failed old rear hook.

  14. Gage for 3-d contours

    NASA Technical Reports Server (NTRS)

    Haynie, C. C.

    1980-01-01

    Simple gage, used with template, can help inspectors determine whether three-dimensional curved surface has correct contour. Gage was developed as aid in explosive forming of Space Shuttle emergency-escape hatch. For even greater accuracy, wedge can be made of metal and calibrated by indexing machine.

  15. GAGES: A stream gage database for evaluating natural and alteredflow conditions in the conterminous United States

    USGS Publications Warehouse

    Falcone, James A.; Carlisle, Daren M.; Wolock, David M.; Meador, Michael R.

    2010-01-01

    In addition, watersheds were assessed for their reference quality within nine broad regions for use in studies intended to characterize stream flows under conditions minimally influenced by human activities. Three primary criteria were used to assess reference quality: (1) a quantitative index of anthropogenic modification within the watershed based on GIS-derived variables, (2) visual inspection of every stream gage and drainage basin from recent high-resolution imagery and topographic maps, and (3) information about man-made influences from USGS Annual Water Data Reports. From the set of 6785 sites, we identified 1512 as reference-quality stream gages. All data derived for these watersheds as well as the reference condition evaluation are provided as an online data set termed GAGES (geospatial attributes of gages for evaluating stream flow).

  16. Inflatable device for installing strain gage bridges

    NASA Technical Reports Server (NTRS)

    Cook, C. E.; Smith, G. E.; Monaghan, R. C. (Inventor)

    1983-01-01

    Methods and devices for installing in a tubular shaft multiple strain gages are disclosed with focus on a method and a device for pneumatically forcing strain gages into seated engagement with the internal surfaces of a tubular shaft in an installation of multiple strain gages in a tubular shaft. The strain gages or other electron devices are seated in a template-like component which is wrapped about a pneumatically expansible body. The component is inserted into a shaft and the body is pneumatically expanded after a suitable adhesive was applied to the surfaces.

  17. Survival of foul-hooked largemouth bass (Micropterus salmoides)

    USGS Publications Warehouse

    Pope, K.L.; Wilde, G.R.

    2010-01-01

    We conducted a field experiment to determine the survival rate of foul-hooked (hooked external to the oral cavity) largemouth bass (Micropterus salmoides) caught and released by recreational anglers. Of 42 largemouth bass caught with hard-plastic baits containing three treble hooks, 15 were hooked only within the mouth and 27 had at least one hook penetrating the external surface of the fish (i.e., foul-hooked). There was no difference in survival of mouth-hooked (100%), foul-hooked (100%), or control (100%) largemouth bass.

  18. Evaluation of the trough-type rain gage

    Treesearch

    Irvin C. Reigner

    1964-01-01

    Although infrequently used, the trough-type rain gage has been described as aerodynamically the most efficient of gages (Hayes and Kittredge 1949). This applies only to the commercial semicircular eave-gutter type of trough and not to troughs rectangular in cross-section. The latter, as well as the upright cylindrical type of gage, produces greater disturbances in the...

  19. Sensitivity of hot-cathode ionization vacuum gages in several gases

    NASA Technical Reports Server (NTRS)

    Holanda, R.

    1972-01-01

    Four hot-cathode ionization vacuum gages were calibrated in 12 gases. The relative sensitivities of these gages were compared to several gas properties. Ionization cross section was the physical property which correlated best with gage sensitivity. The effects of gage accelerating voltage and ionization-cross-section energy level were analyzed. Recommendations for predicting gage sensitivity according to gage type were made.

  20. Getting Hooked on Physics!

    NASA Astrophysics Data System (ADS)

    McHugh, M.; McCauley, V.

    2016-12-01

    A number of papers in this journal have dealt with the idea of using hooks in physics instruction. A hook, as the name suggests, engages students in learning by triggering their attention and interest. Hooks can be any type of pedagogical approach—a question, a demonstration, a puzzle or video. They are generally short and center on the most interesting aspects of a topic. Here we focus on using Conceptual Change (CC) teacher-led demonstrations as the pedagogical hook approach. Conceptual Change is an instructional method mentioned by a number of authors to stimulate interest among learners. This is where an educator presents an issue or topic that has associated misconceptions. As the teacher explains the truth behind the concept, cognitive conflict occurs and the students' initial perceptions are challenged and ideas start to change. However, the instruction used in association with the demonstrations must provide intelligible, plausible, relevant explanations so that students are convinced by the new ideas. The gap between prior knowledge and new knowledge has the potential to provide a strong stimulus for augmenting interest, engagement, and attention among students. Thus, CC can act as a hook in itself.

  1. Triple-material stress-strain resistivity gage

    DOEpatents

    Stout, R.B.

    1987-05-19

    A triple material piezoresistive gage provides multi-component elastic stress or strain measurements. Thin foils of three piezoresistive materials, e.g., ytterbium, manganin, and constantan, are configured in a nested serpentine rectilinear grind or other grind arrangement and embedded in a medium, preferably normal to the direction of shock wave propagation. The output of the gage is a resistivity change history for each material of gage. Each resistivity change is independent of the others so that three diagonal components of the elastic stress or strain tensor can be calculated form the resistivity measurements. 4 figs.

  2. Triple-material stress-strain resistivity gage

    DOEpatents

    Stout, Ray B.

    1988-01-01

    A triple material piezoresistive gage provides multi-component elastic stress or measurements. Thin foils of three piezoresistive materials, e.g. ytterbium, manganin, and constantan, are configured in a nested serpentine rectilinear grid or other grid arrangement and embedded in a medium, preferably normal to the direction of shock wave propagation. The output of the gage is a resistivity change history for each material of the gage. Each resistivity change is independent of the others so that three diagonal components of the elastic stress or strain tensor can be calculated from the resistivity measurements.

  3. Strain gage based determination of mixed mode SIFs

    NASA Astrophysics Data System (ADS)

    Murthy, K. S. R. K.; Sarangi, H.; Chakraborty, D.

    2018-05-01

    Accurate determination of mixed mode stress intensity factors (SIFs) is essential in understanding and analysis of mixed mode fracture of engineering components. Only a few strain gage determination of mixed mode SIFs are reported in literatures and those also do not provide any prescription for radial locations of strain gages to ensure accuracy of measurement. The present investigation experimentally demonstrates the efficacy of a proposed methodology for the accurate determination of mixed mode I/II SIFs using strain gages. The proposed approach is based on the modified Dally and Berger's mixed mode technique. Using the proposed methodology appropriate gage locations (optimal locations) for a given configuration have also been suggested ensuring accurate determination of mixed mode SIFs. Experiments have been conducted by locating the gages at optimal and non-optimal locations to study the efficacy of the proposed approach. The experimental results from the present investigation show that highly accurate SIFs (0.064%) can be determined using the proposed approach if the gages are located at the suggested optimal locations. On the other hand, results also show the very high errors (212.22%) in measured SIFs possible if the gages are located at non-optimal locations. The present work thus clearly substantiates the importance of knowing the optimal locations of the strain gages apriori in accurate determination of SIFs.

  4. Elevated temperature strain gages

    NASA Technical Reports Server (NTRS)

    Brittain, J. O.; Geslin, D.; Lei, J. F.

    1986-01-01

    One of the goals of the HOST Program is the development of electrical resistance strain gages for static strain measurements at temperatures equal to or greater than 1273 K. Strain gage materials must have a reproducible or predictable response to temperature, time and strain. It is the objective of this research to investigate criteria for the selection of materials for such applications through electrical properties studies. The results of the investigation of two groups of materials, refractory compounds and binary alloy solid solutions are presented.

  5. Bi-directional, buried-wire skin-friction gage

    NASA Technical Reports Server (NTRS)

    Higuchi, H.; Peake, D. J.

    1978-01-01

    A compact, nonobtrusive, bi-directional, skin-friction gage was developed to measure the mean shear stress beneath a three-dimensional boundary layer. The gage works by measuring the heat flux from two orthogonal wires embedded in the surface. Such a gage was constructed and its characteristics were determined for different angles of yaw in a calibration experiment in subsonic flow with a Preston tube used as a standard. Sample gages were then used in a fully three-dimensional turbulent boundary layer on a circular cone at high relative incidence, where there were regimes of favorable and adverse pressure gradients and three-dimensional separation. Both the direction and magnitude of skin friction were then obtained on the cone surface.

  6. Triple-material stress-strain resistivity gage

    DOEpatents

    Stout, R.B.

    1988-05-17

    A triple material piezoresistive gage provides multi-component elastic stress measurements is disclosed. Thin foils of three piezoresistive materials, e.g. ytterbium, manganin, and constantan, are configured in a nested serpentine rectilinear grid or other grid arrangement and embedded in a medium, preferably normal to the direction of shock wave propagation. The output of the gage is a resistivity change history for each material of the gage. Each resistivity change is independent of the others so that three diagonal components of the elastic stress or strain tensor can be calculated from the resistivity measurements. 4 figs.

  7. Telescoping magnetic ball bar test gage

    DOEpatents

    Bryan, J.B.

    1984-03-13

    A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengageable servo drives which cannot be clutched out is disclosed. Two gage balls are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit and a rigid member. One gage ball is secured by a magnetic socket knuckle assembly which fixes its center with respect to the machine being tested. The other gage ball is secured by another magnetic socket knuckle assembly which is engaged or held by the machine in such manner that the center of that ball is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball. As the moving ball executes its trajectory, changes in the radial distance between the centers of the two balls caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly actuated by the parallel reed flexure unit. Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball locations, thereby determining the accuracy of the machine. 3 figs.

  8. Telescoping magnetic ball bar test gage

    DOEpatents

    Bryan, J.B.

    1982-03-15

    A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengagable servo drives which cannot be clutched out. Two gage balls are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit and a rigid member. One gage ball is secured by a magnetic socket knuckle assembly which fixes its center with respect to the machine being tested. The other gage ball is secured by another magnetic socket knuckle assembly which is engaged or held by the machine in such manner that the center of that ball is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball. As the moving ball executes its trajectory, changes in the radial distance between the centers of the two balls caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly actuated by the parallel reed flexure unit. Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball locations, thereby determining the accuracy of the machine.

  9. Instability of hooks during bacterial flagellar swimming

    NASA Astrophysics Data System (ADS)

    Jabbarzadeh, Mehdi; Fu, Henry C.; Henry Fu Team

    2016-11-01

    In bacteria, a flexible hook transmits torque from the rotary motor at the cell body to the flagellum. Previously, the hook has been modeled as a Kirchhoff rod between the cell body and rotating flagellum. To study effects of the hook's flexibility on the bacteria's swimming speed and trajectory for wide range hook stiffnesses and flagellum configurations, we develop an efficient simplified spring model for the hook by linearizing the Kirchhoff rod. We treat the hydrodynamics of the cell body and helical flagellum using resistance matrices calculated by the method of regularized Stokeslets. We investigate flagellar and swimming dynamics for a range of hook flexibilities and flagellar orientations relative to the cell body and compare the results to models without hook flexibility. We investigate in detail parameters corresponding to E. coli and Vibrio alginolyticus. Generally, the flagellum changes orientation relative to the cell body, undergoing an orbit with the period of the motor rotation. We find that as the hook stiffness decreases, steady-state orbits of the flagellum first become unstable before the hook buckles, which may suggest a new mechanism of flick initiation in run-reverse-flick motility. We also find that for some parameter ranges, there are multiple stable steady state orbits, which may have implications for the tumbling and turning of bacteria.

  10. 49 CFR 179.400-19 - Valves and gages.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... control of vapor phase pressure, vapor phase venting, liquid transfer and liquid flow rates. All valves... within suitable protective housings. A liquid level gage and a vapor phase pressure gage must be provided... Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400-19 Valves and gages...

  11. 49 CFR 179.400-19 - Valves and gages.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... control of vapor phase pressure, vapor phase venting, liquid transfer and liquid flow rates. All valves... within suitable protective housings. A liquid level gage and a vapor phase pressure gage must be provided... Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400-19 Valves and gages...

  12. 49 CFR 179.400-19 - Valves and gages.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... control of vapor phase pressure, vapor phase venting, liquid transfer and liquid flow rates. All valves... within suitable protective housings. A liquid level gage and a vapor phase pressure gage must be provided... Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400-19 Valves and gages...

  13. 21 CFR 868.5420 - Ether hook.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ether hook. 868.5420 Section 868.5420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5420 Ether hook. (a) Identification. An ether hook is a device...

  14. Subacromial morphometric assessment of the clavicle hook plate.

    PubMed

    ElMaraghy, Amr W; Devereaux, Moira W; Ravichandiran, Kajeandra; Agur, Anne M

    2010-06-01

    Clavicle hook plates are an effective plate fixation alternative for distal clavicle fractures and severe acromioclavicular joint dislocations. However, post-operative complications associated with the subacromial portion of the hook include acromial osteolysis and subacromial impingement. We examine and quantify the three-dimensional position of the subacromial portion of the hook plate relative to surrounding acromial and subacromial structures in a series of cadaveric shoulders to determine if hook positioning predisposes the shoulder to these noted post-operative complications. Fifteen cadaveric shoulders (seven males, eight females) were implanted with 15- or 18-mm hook plates. Dimensions of the acromion and hook plate were digitised and reconstructed into a three-dimensional model to measure acromion dimensions and distances of the subacromial hook relative to surrounding acromial and subacromial structures. Inter-specimen dimensions of the acromion were highly variable. Mean acromion width and thickness were greater in males than in females (p=0.01). The posterior orientation of the subacromial hook varied widely (mean posterior implantation angle=32.5+/-20 degrees, range 0-67 degrees). The hook pierced the subacromial bursa in 13/15 specimens, made contact with the belly of the supraspinatus muscle in 9/15 specimens, and had focal contact at the hook tip with the undersurface of the acromion in 9/15 specimens. The wide range of acromial dimensions leads to a high degree of variability in the positioning of the subacromial hook. The observed frequency of hook contact with surrounding subacromial structures in a static shoulder confirms that the position of the hook portion of the implant can predispose anatomic structures to the post-operative complications of subacromial impingement and bony erosion. Copyright 2009 Elsevier Ltd. All rights reserved.

  15. 29 CFR 1915.113 - Shackles and hooks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... bends or springs the hook. (3) Hooks shall be inspected periodically to see that they have not been bent by overloading. Bent or sprung hooks shall not be used. [47 FR 16986, Apr. 20, 1982, as amended at 51...

  16. 29 CFR 1915.113 - Shackles and hooks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... bends or springs the hook. (3) Hooks shall be inspected periodically to see that they have not been bent by overloading. Bent or sprung hooks shall not be used. [47 FR 16986, Apr. 20, 1982, as amended at 51...

  17. Stage measurement at gaging stations

    USGS Publications Warehouse

    Sauer, Vernon B.; Turnipseed, D. Phil

    2010-01-01

    Stream and reservoir stage are critical parameters in the computation of stream discharge and reservoir volume, respectively. In addition, a record of stream stage is useful in the design of structures that may be affected by stream elevation, as well as for the planning for various uses of flood plains. This report describes equipment and methodology for the observation, sensing, and recording of stage in streams and reservoirs. Although the U.S. Geological Survey (USGS) still uses the traditional, basic stilling-well float system as a predominant gaging station, modern electronic stage sensors and water-level recorders are now commonly used. Bubble gages coupled with nonsubmersible pressure transducers eliminate the need for stilling wells. Submersible pressure transducers have become common in use for the measurement of stage in both rivers and lakes. Furthermore, noncontact methods, such as radar, acoustic, and laser methods of sensing water levels, are being developed and tested, and in the case of radar, are commonly used for the measurement of stage. This report describes commonly used gaging-station structures, as well as the design and operation of gaging stations. Almost all of the equipment and instruments described in this report will meet the accuracy standard set by the USGS Office of Surface Water (OSW) for the measurement of stage for most applications, which is ±0.01 foot (ft) or 0.2 percent of the effective stage. Several telemetry systems are used to transmit stage data from the gaging station to the office, although satellite telemetry has become the standard. These telemetry systems provide near real-time stage data, as well as other information that alerts the hydrographer to extreme or abnormal events, and instrument malfunctions.

  18. Experiments with windshields for precipitation gages

    Treesearch

    C. C. Warnick

    1953-01-01

    Under cooperative encouragement from several Federal agencies, the Engineering Experiment Station of the University of Idaho has been studying the principles, development, and use of high-altitude precipitation gages. A low-speed wind tunnel has been used to study the effect of wind on the catching characteristics of model storage precipitation gages. A snow storm was...

  19. Telescoping magnetic ball bar test gage

    DOEpatents

    Bryan, James B.

    1984-01-01

    A telescoping magnetic ball bar test gage for determining the accuracy of machine tools, including robots, and those measuring machines having non-disengageable servo drives which cannot be clutched out. Two gage balls (10, 12) are held and separated from one another by a telescoping fixture which allows them relative radial motional freedom but not relative lateral motional freedom. The telescoping fixture comprises a parallel reed flexure unit (14) and a rigid member (16, 18, 20, 22, 24). One gage ball (10) is secured by a magnetic socket knuckle assembly (34) which fixes its center with respect to the machine being tested. The other gage ball (12) is secured by another magnetic socket knuckle assembly (38) which is engaged or held by the machine in such manner that the center of that ball (12) is directed to execute a prescribed trajectory, all points of which are equidistant from the center of the fixed gage ball (10). As the moving ball (12) executes its trajectory, changes in the radial distance between the centers of the two balls (10, 12) caused by inaccuracies in the machine are determined or measured by a linear variable differential transformer (LVDT) assembly (50, 52, 54, 56, 58, 60) actuated by the parallel reed flexure unit (14). Measurements can be quickly and easily taken for multiple trajectories about several different fixed ball (10) locations, thereby determining the accuracy of the machine.

  20. Strain gage installation and survivability on geosynthetics used in flexible pavements

    NASA Astrophysics Data System (ADS)

    Brooks, Jeremy A.

    The use of foil type strain gages on geosynthetics is poorly documented. In addition, very few individuals are versed in proper installation techniques or calibration methods. Due to the limited number of knowledgeable technicians there is no information regarding the susceptibility of theses gages to errors in installation by inexperienced installers. Also lacking in the documentation related to the use of foil type strain gages on geosynthetics is the survivability of the gages in field conditions. This research documented procedures for installation, calibration, and survivability used by the project team to instruments a full scale field installation in Marked Tree, AR. This research also addressed sensitivity to installation errors on both geotextile and geogrid. To document the process of gage installation an experienced technician, Mr. Joe Ables, formerly of the UASCE Waterways Experiment Station, was consulted. His techniques were combined with those discovered in related literature and those developed by the research team to develop processes that were adaptable to multiple gage geometries and parent geosynthetics. These processes were described and documented in a step by step manner with accompanying photographs, which should allow virtually anyone with basic electronics knowledge to install these gages properly. Calibration of the various geosynthetic / strain gage combinations was completed using wide width tensile testing on multiple samples of each material. The tensile testing process was documented and analyzed using digital photography to analyze strain on the strain gage itself. Calibration factors for each geosynthtics used in the full scale field testing were developed. In addition, the process was thoroughly documented to allow future researchers to calibrate additional strain gage and geosynthetic combinations. The sensitivity of the strain gages to installation errors was analyzed using wide width tensile testing and digital photography to

  1. Microprocessor-based multichannel flutter monitor using dynamic strain gage signals

    NASA Technical Reports Server (NTRS)

    Smalley, R. R.

    1976-01-01

    Two microprocessor-based multichannel monitors for monitoring strain gage signals during aerodynamic instability (flutter) testing in production type turbojet engines were described. One system monitors strain gage signals in the time domain and gives an output indication whenever the signal amplitude of any gage exceeds a pre-set alarm or abort level for that particular gage. The second system monitors the strain gage signals in the frequency domain and therefore is able to use both the amplitude and frequency information. Thus, an alarm signal is given whenever the spectral content of the strain gage signal exceeds, at any point, its corresponding amplitude vs. frequency limit profiles. Each system design is described with details on design trade-offs, hardware, software, and operating experience.

  2. Gage for measuring coastal erosion and sedimentation

    NASA Technical Reports Server (NTRS)

    Carpini, T. D.; Moughon, W. C.

    1970-01-01

    Underwater sand height gage, which measures heights up to 12 inches, is comprised of two standard flush-diaphragm pressure transducers. Gage is very sensitive to buried water heights and is useful as a research tool in study of wet earth and landslide phenomena.

  3. "Hooking up" among college students: demographic and psychosocial correlates.

    PubMed

    Owen, Jesse J; Rhoades, Galena K; Stanley, Scott M; Fincham, Frank D

    2010-06-01

    This study investigated 832 college students' experiences with hooking up, a term that refers to a range of physically intimate behavior (e.g., passionate kissing, oral sex, and intercourse) that occurs outside of a committed relationship. Specifically, we examined how five demographic variables (sex, ethnicity, parental income, parental divorce, and religiosity) and six psychosocial factors (e.g., attachment styles, alcohol use, psychological well-being, attitudes about hooking up, and perceptions of the family environment) related to whether individuals had hooked up in the past year. Results showed that similar proportions of men and women had hooked up but students of color were less likely to hook up than Caucasian students. More alcohol use, more favorable attitudes toward hooking up, and higher parental income were associated with a higher likelihood of having hooked up at least once in the past year. Positive, ambivalent, and negative emotional reactions to the hooking up experience(s) were also examined. Women were less likely to report that hooking up was a positive emotional experience than men. Young adults who reported negative and ambivalent emotional reactions to hooking up also reported lower psychological well-being and less favorable attitudes toward hooking up as compared to students who reported a positive hooking up experience. Based on these findings, suggestions for psychoeducational programming are offered. Additionally, directions for future research are provided.

  4. Mechanics of plant fruit hooks

    PubMed Central

    Chen, Qiang; Gorb, Stanislav N.; Gorb, Elena; Pugno, Nicola

    2013-01-01

    Hook-like surface structures, observed in some plant species, play an important role in the process of plant growth and seed dispersal. In this study, we developed an elastic model and further used it to investigate the mechanical behaviour of fruit hooks in four plant species, previously measured in an experimental study. Based on Euler–Bernoulli beam theory, the force–displacement relationship is derived, and its Young's modulus is obtained. The result agrees well with the experimental data. The model aids in understanding the mechanics of hooks, and could be used in the development of new bioinspired Velcro-like materials. PMID:23365190

  5. Evaluation results of the 700 deg C Chinese strain gages

    NASA Technical Reports Server (NTRS)

    Hobart, H. F.

    1984-01-01

    There is a continuing interest and need for resistance strain gages capable of making static strain measurements on components located in the hot section of gas turbine engines. A paper by Tsen-tai Wu describes the development and evaluation of high temperature gauges fabricated from specially developed Fe-Cr-Al-V-Ti-Y alloy wire. Several of these gages and a quantity of P12-2 ceramic adhesive were purchased for evaluation. Nine members of the aircraft turbine engine community were invited to participate in an evaluation of these gages. Each participant was sent one strain gage, a small amount of ceramic adhesive, instructions for mounting the gage on a test beam, and a set of suggestions for the experiment. Data on gage factor variation with temperature, apparent strain, and drift are discussed.

  6. Robert Hooke, 1635-1703.

    PubMed

    Rowbury, Robin

    2012-01-01

    Robert Hooke was a polymath whose expertise during the 17th century spanned many different scientific areas. As a schoolboy on the Isle of Wight he was obsessed with the possibility of human flight and later became equally absorbed in cosmology and planetary motion. His skills as an artist were put to good use both as an architect following the Great Fire of London and before that in Micrographia. Although that book is best known for demonstrating the power of Hooke's microscope, Micrographia describes distant planetary bodies, the wave theory of light, the organic origin of fossils, and various other philosophical and scientific interests of its author The following thumbnail sketches of Hooke reveal him to be a man of enormous energy and imagination whose ideas were often pirated or under-rated.

  7. Synthetic Minor NSR Permit: Van Hook Crude Terminal, LLC - Van Hook Crude Terminal/Rail Loading Facility

    EPA Pesticide Factsheets

    This page contains the current effective synthetic minor NSR permit for the Van Hook Crude Terminal, LLC, Van Hook Crude Terminal/Rail Loading Facility, located on the Fort Berthold Indian Reservation in Mountrail County, ND.

  8. Designing physics video hooks for science students

    NASA Astrophysics Data System (ADS)

    McHugh, M.; McCauley, V.

    2016-01-01

    This paper offers an insight into the design structure of physics video hooks that were developed by the Science Education Resource design team in the school of education (SOE) in National University of Ireland, Galway (NUI Galway). A hook, is an instructional technique used to stimulate student attention (Hunter 1994, Lemov 2010), interest (Jewett 2013) and engagement (McCrory 2011, Riendeau 2013). The physics video hooks followed a design framework that is illustrated below by breaking down the centre of gravity (COG) hook. Various design principles and elements embedded within the COG hook are presented with examples and the time they occur within the video. The intention of this article is that the design can be replicated and modified to aid teachers and designers in the development of a multitude of classroom based multimedia resources.

  9. Bonding of strain gages to fiber reinforced composite plastic materials

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.; Hanson, M. P.; Serafini, T. T.

    1970-01-01

    Strain gage is installed during molding of composite and utilizes the adhesive properties of the matrix resin in the composite to bond the strain gage in place. Gages thus embedded provide data at all temperatures that the matrix can withstand.

  10. Cost effectiveness of the stream-gaging program in Louisiana

    USGS Publications Warehouse

    Herbert, R.A.; Carlson, D.D.

    1985-01-01

    This report documents the results of a study of the cost effectiveness of the stream-gaging program in Louisiana. Data uses and funding sources were identified for the 68 continuous-record stream gages currently (1984) in operation with a budget of $408,700. Three stream gages have uses specific to a short-term study with no need for continued data collection beyond the study. The remaining 65 stations should be maintained in the program for the foreseeable future. In addition to the current operation of continuous-record stations, a number of wells, flood-profile gages, crest-stage gages, and stage stations, are serviced on the continuous-record station routes; thus, increasing the current budget to $423,000. The average standard error of estimate for data collected at the stations is 34.6%. Standard errors computed in this study are one measure of streamflow errors, and can be used as guidelines in comparing the effectiveness of alternative networks. By using the routes and number of measurements prescribed by the ' Traveling Hydrographer Program, ' the standard error could be reduced to 31.5% with the current budget of $423,000. If the gaging resources are redistributed, the 34.6% overall level of accuracy at the 68 continuous-record sites and the servicing of the additional wells or gages could be maintained with a budget of approximately $410,000. (USGS)

  11. Cost effectiveness of the stream-gaging program in Ohio

    USGS Publications Warehouse

    Shindel, H.L.; Bartlett, W.P.

    1986-01-01

    This report documents the results of the cost effectiveness of the stream-gaging program in Ohio. Data uses and funding sources were identified for 107 continuous stream gages currently being operated by the U.S. Geological Survey in Ohio with a budget of $682,000; this budget includes field work for other projects and excludes stations jointly operated with the Miami Conservancy District. No stream gage were identified as having insufficient reason to continue their operation; nor were any station identified as having uses specifically only for short-term studies. All 107 station should be maintained in the program for the foreseeable future. The average standard error of estimation of stream flow records is 29.2 percent at its present level of funding. A minimum budget of $679,000 is required to operate the 107-gage program; a budget less than this does no permit proper service and maintenance of the gages and recorders. At the minimum budget, the average standard error is 31.1 percent The maximum budget analyzed was $1,282,000, which resulted in an average standard error of 11.1 percent. A need for additional gages has been identified by the other agencies that cooperate in the program. It is suggested that these gage be installed as funds can be made available.

  12. NASA LaRC Strain Gage Balance Design Concepts

    NASA Technical Reports Server (NTRS)

    Rhew, Ray D.

    1999-01-01

    The NASA Langley Research Center (LaRC) has been designing strain-gage balances for more than fifty years. These balances have been utilized in Langley's wind tunnels, which span over a wide variety of aerodynamic test regimes, as well as other ground based test facilities and in space flight applications. As a result, the designs encompass a large array of sizes, loads, and environmental effects. Currently Langley has more than 300 balances available for its researchers. This paper will focus on the design concepts for internal sting mounted strain-gage balances. However, these techniques can be applied to all force measurement design applications. Strain-gage balance concepts that have been developed over the years including material selection, sting, model interfaces, measuring, sections, fabrication, strain-gaging and calibration will be discussed.

  13. Performance of barbed and barbless hooks in a marine recreational fishery

    USGS Publications Warehouse

    Schaeffer, Jeffrey S.; Hoffman, Elizabeth M.

    2002-01-01

    We used an angling study to examine catch per unit effort (CPUE), bait loss, and total landings by anglers fishing with natural bait on barbed and barbless hooks in a nearshore marine sport fishery located in the Gulf of Mexico near St. Petersburg, Florida. Anglers fished half the day with a barbed hook and half the day with a barbless hook. We also recorded anatomical hook placement, severity of injury or bleeding, and hook extraction times for each landed fish. Bait loss, CPUE, and mean length of catch did not differ between gears, but anglers landed 22% more fish with barbed hooks. Loss of hooked fish was significantly higher with barbless hooks, and efficiency appeared to vary among species. Mean unhooking times were significantly shorter with barbless hooks. Anatomical hook placement did not differ between gears and most fish were hooked in the jaws. Bleeding did not differ between gears because bleeding was influenced strongly by hook placement, but barbless hooks reduced unhooking injuries. In this fishery, barbless hooks probably did not reduce hooking mortality and conferred only slight benefits at the expense of reduced catches.

  14. Clathrin-Mediated Auxin Efflux and Maxima Regulate Hypocotyl Hook Formation and Light-Stimulated Hook Opening in Arabidopsis.

    PubMed

    Yu, Qinqin; Zhang, Ying; Wang, Juan; Yan, Xu; Wang, Chao; Xu, Jian; Pan, Jianwei

    2016-01-04

    The establishment of auxin maxima by PIN-FORMED 3 (PIN3)- and AUXIN RESISTANT 1/LIKE AUX1 (LAX) 3 (AUX1/LAX3)-mediated auxin transport is essential for hook formation in Arabidopsis hypocotyls. Until now, however, the underlying regulatory mechanism has remained poorly understood. Here, we show that loss of function of clathrin light chain CLC2 and CLC3 genes enhanced auxin maxima and thereby hook curvature, alleviated the inhibitory effect of auxin overproduction on auxin maxima and hook curvature, and delayed blue light-stimulated auxin maxima reduction and hook opening. Moreover, pharmacological experiments revealed that auxin maxima formation and hook curvature in clc2 clc3 were sensitive to auxin efflux inhibitors 1-naphthylphthalamic acid and 2,3,5-triiodobenzoic acid but not to the auxin influx inhibitor 1-naphthoxyacetic acid. Live-cell imaging analysis further uncovered that loss of CLC2 and CLC3 function impaired PIN3 endocytosis and promoted its lateralization in the cortical cells but did not affect AUX1 localization. Taken together, these results suggest that clathrin regulates auxin maxima and thereby hook formation through modulating PIN3 localization and auxin efflux, providing a novel mechanism that integrates developmental signals and environmental cues to regulate plant skotomorphogenesis and photomorphogenesis. Copyright © 2016 The Author. Published by Elsevier Inc. All rights reserved.

  15. Resistance fail strain gage technology as applied to composite materials

    NASA Technical Reports Server (NTRS)

    Tuttle, M. E.; Brinson, H. F.

    1985-01-01

    Existing strain gage technologies as applied to orthotropic composite materials are reviewed. The bonding procedures, transverse sensitivity effects, errors due to gage misalignment, and temperature compensation methods are addressed. Numerical examples are included where appropriate. It is shown that the orthotropic behavior of composites can result in experimental error which would not be expected based on practical experience with isotropic materials. In certain cases, the transverse sensitivity of strain gages and/or slight gage misalignment can result in strain measurement errors.

  16. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  17. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  18. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  19. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  20. 49 CFR 213.355 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Frog guard rails and guard faces; gage. 213.355... Higher § 213.355 Frog guard rails and guard faces; gage. The guard check and guard face gages in frogs... distance between the gage line of a frog to the guard line 1 of its guard rail or guarding face, measured...

  1. Cooling system for three hook ring segment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, Christian X.; Eng, Darryl; Lee, Ching-Pang

    2014-08-26

    A triple hook ring segment including forward, midsection and aft mounting hooks for engagement with respective hangers formed on a ring segment carrier for supporting a ring segment panel, and defining a forward high pressure chamber and an aft low pressure chamber on opposing sides of the midsection mounting hook. An isolation plate is provided on the aft side of the midsection mounting hook to form an isolation chamber between the aft low pressure chamber and the ring segment panel. High pressure air is supplied to the forward chamber and flows to the isolation chamber through crossover passages in themore » midsection hook. The isolation chamber provides convection cooling air to an aft portion of the ring segment panel and enables a reduction of air pressure in the aft low pressure chamber to reduce leakage flow of cooling air from the ring segment.« less

  2. Cost effectiveness of the stream-gaging program in Pennsylvania

    USGS Publications Warehouse

    Flippo, H.N.; Behrendt, T.E.

    1985-01-01

    This report documents a cost-effectiveness study of the stream-gaging program in Pennsylvania. Data uses and funding were identified for 223 continuous-record stream gages operated in 1983; four are planned for discontinuance at the close of water-year 1985; two are suggested for conversion, at the beginning of the 1985 water year, for the collection of only continuous stage records. Two of 11 special-purpose short-term gages are recommended for continuation when the supporting project ends; eight of these gages are to be discontinued and the other will be converted to a partial-record type. Current operation costs for the 212 stations recommended for continued operation is $1,199,000 per year in 1983. The average standard error of estimation for instantaneous streamflow is 15.2%. An overall average standard error of 9.8% could be attained on a budget of $1,271,000, which is 6% greater than the 1983 budget, by adopted cost-effective stream-gaging operations. (USGS)

  3. Scale factor gage for fiber optics inspection device

    NASA Technical Reports Server (NTRS)

    Mcmahon, W.; Sugg, F. E.

    1971-01-01

    Flexible wire device, fastened along outside of fiber bundle from viewing portion to tip, positions calibrated adjustable gage in field of view. Scale factor is determined from known magnification characteristics of fiber optics system or from graduations on gage tip.

  4. The Topic Is Sandy Hook: A Program for Gifted and Talented Students at Sandy Hook.

    ERIC Educational Resources Information Center

    Grant, David

    "The Topic Is Sandy Hook" is an experiential 10-week program designed to provide special opportunities and educational experiences for 6th to 10th grade gifted and talented students. Sandy Hook, a natural resource in Monmouth County, New Jersey, is unique in its physical and historical features and provides an exceptionally rich environment in…

  5. Cost effectiveness of the stream-gaging program in North Dakota

    USGS Publications Warehouse

    Ryan, Gerald L.

    1989-01-01

    This report documents results of a cost-effectiveness study of the stream-gaging program In North Dakota. It is part of a nationwide evaluation of the stream-gaging program of the U.S. Geological Survey.One phase of evaluating cost effectiveness is to identify less costly alternative methods of simulating streamflow records. Statistical or hydro logic flow-routing methods were used as alternative methods to simulate streamflow records for 21 combinations of gaging stations from the 94-gaging-station network. Accuracy of the alternative methods was sufficient to consider discontinuing only one gaging station.Operation of the gaging-station network was evaluated by using associated uncertainty in streamflow records. The evaluation was limited to the nonwinter operation of 29 gaging stations in eastern North Dakota. The current (1987) travel routes and measurement frequencies require a budget of about $248/000 and result in an average equivalent Gaussian spread in streamflow records of 16.5 percent. Changes in routes and measurement frequencies optimally could reduce the average equivalent Gaussian spread to 14.7 percent.Budgets evaluated ranged from $235,000 to $400,000. A $235,000 budget would increase the optimal average equivalent Gaussian spread from 14.7 to 20.4 percent, and a $400,000 budget could decrease it to 5.8 percent.

  6. 27. Detail view of mechanical float gages used to monitor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. Detail view of mechanical float gages used to monitor level of water in the filtration bed reservoir. Gage on left measures water head, gage on right monitors filtration rate. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  7. Development and characterization of PdCr temperature-compensated wire resistance strain gage

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen

    1989-01-01

    A temperature-compensated resistance static strain gage with potential to be used to 600 C was recently developed. Gages were fabricated from specially developed palladium-13 w/o chromium (Pd-13Cr) wire and platinum (Pt) compensator. When bonded to high temperature Hastelloy X, the apparent strain from room temperature to 600 C was within 400 microstrain for gages with no preheat treatment and within 3500 microstrain for gages with 16 hours prestabilization at 640 C. The apparent strain versus temperature relationship of stabilized PdCr gages were repeatable with the reproducibility within 100 microstrain during three thermal cycles to 600 C and an 11 hours soak at 600 C. The gage fabrication, construction and installation is described. Also, the coating system used for this compensated resistance strain gage is explained. The electrical properties of the strain sensing element and main characteristics of the compensated gage including apparent strain, drift and reproducibility are discussed.

  8. String Technique for Anterior Orbital Fish Hook Removal.

    PubMed

    Starr, Matthew R; Choi, Michael B; Mahr, Michael A; Mettu, Pradeep; Patterson, David F

    2018-06-13

    Removing fish hooks is a common procedure performed by many emergency department providers. There are several techniques that are commonly employed to aid in successful removal. However, when a fish hook becomes embedded within the orbit, there are limited options as to avoid damaging vital surrounding structures. The authors report the removal of a fish hook within the anterior orbit using the string technique in a 25-year-old patient. The procedure was performed under general anesthesia with the aid of size 5 polyglactin suture wrapped around the hook. The procedure itself took less than 10 seconds and was successful in swiftly and safely removing the hook without damaging surrounding orbital structures. The patient recovered well without any permanent sequelae.

  9. Microanatomy of the cochlear hook

    NASA Astrophysics Data System (ADS)

    Kwan, Changyow Claire; Tan, Xiaodong; Stock, Stuart R.; Soriano, Carmen; Xiao, Xianghui; Richter, Claus-Peter

    2017-09-01

    Communication among humans occurs through coding and decoding of acoustic information. The inner ear or cochlea acts as a frequency analyzer and divides the acoustic signal into small frequency bands, which are processed at different sites along the cochlea. The mechano-electrical conversion is accomplished by the soft tissue structures in the cochlea. While the anatomy for most of the cochlea has been well described, a detailed description of the very high frequency and vulnerable cochlear hook region is missing. To study the cochlear hook, mice cochleae were imaged with synchrotron radiation and high-resolution reconstructions have been made from the tomographic scans. This is the first detailed description of the bony and soft tissues of the hook region of the mammalian cochlea.

  10. Strain gage selection in loads equations using a genetic algorithm

    NASA Technical Reports Server (NTRS)

    1994-01-01

    Traditionally, structural loads are measured using strain gages. A loads calibration test must be done before loads can be accurately measured. In one measurement method, a series of point loads is applied to the structure, and loads equations are derived via the least squares curve fitting algorithm using the strain gage responses to the applied point loads. However, many research structures are highly instrumented with strain gages, and the number and selection of gages used in a loads equation can be problematic. This paper presents an improved technique using a genetic algorithm to choose the strain gages used in the loads equations. Also presented are a comparison of the genetic algorithm performance with the current T-value technique and a variant known as the Best Step-down technique. Examples are shown using aerospace vehicle wings of high and low aspect ratio. In addition, a significant limitation in the current methods is revealed. The genetic algorithm arrived at a comparable or superior set of gages with significantly less human effort, and could be applied in instances when the current methods could not.

  11. High Temperature Capacitive Strain Gage

    NASA Technical Reports Server (NTRS)

    Wnuk, Stephen P., Jr.; Wnuk, Stephen P., III; Wnuk, V. P.

    1990-01-01

    Capacitive strain gages designed for measurements in wind tunnels to 2000 F were built and evaluated. Two design approaches were followed. One approach was based on fixed capacitor plates with a movable ground plane inserted between the plates to effect differential capacitive output with strain. The second approach was based on movable capacitor plates suspended between sapphire bearings, housed in a rugged body, and arranged to operate as a differential capacitor. A sapphire bearing gage (1/4 in. diameter x 1 in. in size) was built with a range of 50,000 and a resolution of 200 microstrain. Apparent strain on Rene' 41 was less than + or - 1000 microstrain from room temperature to 2000 F. Three gage models were built from the Ground Plane Differential concept. The first was 1/4 in. square by 1/32 in. high and useable to 700 F. The second was 1/2 in. square by 1/16 in. high and useable to 1440 F. The third, also 1/2 in. square by 1/16 in. high was expected to operate in the 1600 to 2000 F range, but was not tested because time and funding ended.

  12. High temperature capacitive strain gage

    NASA Astrophysics Data System (ADS)

    Wnuk, Stephen P., Jr.; Wnuk, Stephen P., III; Wnuk, V. P.

    1990-01-01

    Capacitive strain gages designed for measurements in wind tunnels to 2000 F were built and evaluated. Two design approaches were followed. One approach was based on fixed capacitor plates with a movable ground plane inserted between the plates to effect differential capacitive output with strain. The second approach was based on movable capacitor plates suspended between sapphire bearings, housed in a rugged body, and arranged to operate as a differential capacitor. A sapphire bearing gage (1/4 in. diameter x 1 in. in size) was built with a range of 50,000 and a resolution of 200 microstrain. Apparent strain on Rene' 41 was less than + or - 1000 microstrain from room temperature to 2000 F. Three gage models were built from the Ground Plane Differential concept. The first was 1/4 in. square by 1/32 in. high and useable to 700 F. The second was 1/2 in. square by 1/16 in. high and useable to 1440 F. The third, also 1/2 in. square by 1/16 in. high was expected to operate in the 1600 to 2000 F range, but was not tested because time and funding ended.

  13. Two fault tolerant toggle-hook release

    NASA Technical Reports Server (NTRS)

    Graves, Thomas Joseph (Inventor); Brown, Christopher William (Inventor)

    1991-01-01

    A coupling device is disclosed which is mechanically two fault tolerant for release. The device comprises a fastener plate and fastener body, each of which is attachable to a different one of a pair of structures to be joined. The fastener plate and body are coupled by an elongate toggle mounted at one end in a socket on the fastener plate for universal pivotal movement thereon. The other end of the toggle is received in an opening in the fastener body and adapted for limited pivotal movement therein. The toggle is adapted to be restrained by three latch hooks arranged in symmetrical equiangular spacing about the axis of the toggle, each hook being mounted on the fastener body for pivotal movement between an unlatching non-contact position with respect to the toggle and a latching position in engagement with a latching surface of the toggle. The device includes releasable lock means for locking each latch hook in its latching position whereby the toggle couples the fastener plate to the fastener body and means for releasing the lock means to unlock each said latch hook from the latch position whereby the unlocking of at least one of the latch hooks from its latching position results in the decoupling of the fastener plate from the fastener body.

  14. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  15. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  16. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  17. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  18. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  19. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  20. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  1. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  2. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  3. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  4. Gage monitors quality of cross-wire resistance welds

    NASA Technical Reports Server (NTRS)

    Etzel, J.; Piltch, A.

    1968-01-01

    Gage nondestructively monitors the quality of cross-wire resistance welds during the welding operation. The gage gives a dial indication of the relative embedment of the cross wires during the actual welding operation. A direct relationship exists between the depth of embedment and both weld strength and consistency.

  5. Empirical Observations on the Sensitivity of Hot Cathode Ionization Type Vacuum Gages

    NASA Technical Reports Server (NTRS)

    Summers, R. L.

    1969-01-01

    A study of empirical methods of predicting tile relative sensitivities of hot cathode ionization gages is presented. Using previously published gage sensitivities, several rules for predicting relative sensitivity are tested. The relative sensitivity to different gases is shown to be invariant with gage type, in the linear range of gage operation. The total ionization cross section, molecular and molar polarizability, and refractive index are demonstrated to be useful parameters for predicting relative gage sensitivity. Using data from the literature, the probable error of predictions of relative gage sensitivity based on these molecular properties is found to be about 10 percent. A comprehensive table of predicted relative sensitivities, based on empirical methods, is presented.

  6. Development of strain gages for use to 1311 K (1900 F)

    NASA Technical Reports Server (NTRS)

    Lemcoe, M. M.

    1974-01-01

    A high temperature electric resistance strain gage system was developed and evaluated to 1366 K (2000 F) for periods of at least one hour. Wire fabricated from a special high temperature strain gage alloy (BCL-3), was used to fabricate the gages. Various joining techniques (NASA butt welding, pulse arc, plasma needle arc, and dc parallel gap welding) were investigated for joining gage filaments to each other, gage filaments to lead-tab ribbons, and lead-tab ribbons to lead wires. The effectiveness of a clad-wire concept as a means of minimizing apparent strain of BCL-3 strain gages was investigated by sputtering platinum coatings of varying thicknesses on wire samples and establishing the optimum coating thickness--in terms of minimum resistivity changes with temperature. Finally, the moisture-proofing effectiveness of barrier coatings subjected to elevated temperatures was studied, and one commercial barrier coating (BLH Barrier H Waterproofing) was evaluated.

  7. Drawings of fossils by Robert Hooke and Richard Waller

    PubMed Central

    Kusukawa, Sachiko

    2013-01-01

    The drawings of fossils by Robert Hooke and Richard Waller that were the basis of the engravings in Hooke's Posthumous works (1705) are published here for the first time. The drawings show that both Hooke and Waller were proficient draftsmen with a keen eye for the details of petrified objects. These drawings provided Hooke with a polemic edge in making the case for the organic origins of ‘figured stones’.

  8. Development of gage widening projection parameter for the deployable gage restraint measurement system

    DOT National Transportation Integrated Search

    2006-10-01

    Recent gage restraint measurement system (GRMS) developments include the redesign of GRMS vehicles to conduct testing from a deployable axle instead of using freight truck mounted axle and GRMS on hi-rail vehicles. This new test configuration results...

  9. Theory and Practice of Shear/Stress Strain Gage Hygrometry

    NASA Technical Reports Server (NTRS)

    Shams, Qamar A.; Fenner, Ralph L.

    2006-01-01

    Mechanical hygrometry has progressed during the last several decades from crude hygroscopes to state-of-the art strain-gage sensors. The strain-gage devices vary from different metallic beams to strain-gage sensors using cellulose crystallite elements, held in full shear restraint. This old technique is still in use but several companies are now actively pursuing development of MEMS miniaturized humidity sensors. These new sensors use polyimide thin film for water vapor adsorption and desorption. This paper will provide overview about modern humidity sensors.

  10. Hook1 inhibits malignancy and epithelial-mesenchymal transition in hepatocellular carcinoma.

    PubMed

    Sun, Xu; Zhang, Qi; Chen, Wei; Hu, Qida; Lou, Yu; Fu, Qi-Han; Zhang, Jing-Ying; Chen, Yi-Wen; Ye, Long-Yun; Wang, Yi; Xie, Shang-Zhi; Hu, Li-Qiang; Liang, Ting-Bo; Bai, Xue-Li

    2017-07-01

    Hook1 is a member of the hook family of coiled-coil proteins, which is recently found to be associated with malignant tumors. However, its biological function in hepatocellular carcinoma is yet unknown. Here, we evaluated the Hook1 levels in human hepatocellular carcinoma samples and matched peritumoral tissues by real-time polymerase chain reaction. Small interfering RNA knockdown and a transforming growth factor-β-induced epithelial-mesenchymal transition model were employed to investigate the biological effects of Hook1 in hepatocellular carcinoma. Our results indicated that Hook1 levels were significantly lower in hepatocellular carcinoma tissues than in the peritumoral tissues. In addition, Hook1 expression was significantly associated with hepatocellular carcinoma malignancy. Hook1 was downregulated after transforming growth factor-β-induced epithelial-mesenchymal transition. Moreover, Hook1 knockdown promoted epithelial-mesenchymal transition and attenuated the sensitivity of hepatocellular carcinoma cells to doxorubicin. In summary, our results indicate that downregulation of Hook1 plays a pivotal role in hepatocellular carcinoma progression via epithelial-mesenchymal transition. Hook1 may be used as a novel marker and therapeutic molecular target in hepatocellular carcinoma.

  11. Field manual for the collection of Navajo Nation streamflow-gage data

    USGS Publications Warehouse

    Hart, Robert J.; Fisk, Gregory G.

    2014-01-01

    The Field Manual for the Collection of Navajo Nation Streamflow-Gage Data (Navajo Field Manual) is based on established (standard) U.S. Geological Survey streamflow-gaging methods and provides guidelines specifically designed for the Navajo Department of Water Resources personnel who establish and maintain streamflow gages. The Navajo Field Manual addresses field visits, including essential field equipment and the selection of and routine visits to streamflow-gaging stations, examines surveying methods for determining peak flows (indirect measurements), discusses safety considerations, and defines basic terms.

  12. Cost effectiveness of the stream-gaging program in Nevada

    USGS Publications Warehouse

    Arteaga, F.E.

    1990-01-01

    The stream-gaging network in Nevada was evaluated as part of a nationwide effort by the U.S. Geological Survey to define and document the most cost-effective means of furnishing streamflow information. Specifically, the study dealt with 79 streamflow gages and 2 canal-flow gages that were under the direct operation of Nevada personnel as of 1983. Cost-effective allocations of resources, including budget and operational criteria, were studied using statistical procedures known as Kalman-filtering techniques. The possibility of developing streamflow data at ungaged sites was evaluated using flow-routing and statistical regression analyses. Neither of these methods provided sufficiently accurate results to warrant their use in place of stream gaging. The 81 gaging stations were being operated in 1983 with a budget of $465,500. As a result of this study, all existing stations were determined to be necessary components of the program for the foreseeable future. At the 1983 funding level, the average standard error of streamflow records was nearly 28%. This same overall level of accuracy could have been maintained with a budget of approximately $445,000 if the funds were redistributed more equitably among the gages. The maximum budget analyzed, $1,164 ,000 would have resulted in an average standard error of 11%. The study indicates that a major source of error is lost data. If perfectly operating equipment were available, the standard error for the 1983 program and budget could have been reduced to 21%. (Thacker-USGS, WRD)

  13. Effect of gage size on the measurement of local heat flux. [formulas for determining gage averaging errors

    NASA Technical Reports Server (NTRS)

    Baumeister, K. J.; Papell, S. S.

    1973-01-01

    General formulas are derived for determining gage averaging errors of strip-type heat flux meters used in the measurement of one-dimensional heat flux distributions. In addition, a correction procedure is presented which allows a better estimate for the true value of the local heat flux. As an example of the technique, the formulas are applied to the cases of heat transfer to air slot jets impinging on flat and concave surfaces. It is shown that for many practical problems, the use of very small heat flux gages is often unnecessary.

  14. BOOK REVIEW: Robert Hooke and the Royal Society

    NASA Astrophysics Data System (ADS)

    Brown, Neil

    2000-01-01

    Many physics students only come across Hooke when they learn his law of stretching springs, which is a pity because it is just one of his contributions to progress in science, and a minor one at that. His, Micrographia, the first great book of microscopical observations, arouses admiration to this day. He was also active in horology, astronomy, geology and surveying, and he took part in biological experiments, transfusing blood between animals. Much of his work was done while he was curator of experiments for the Royal Society, in which he was involved almost from its foundation. This was by no means a full-time occupation, however. After the Great Fire of London, Hooke was appointed one of the three surveyors for the rebuilding of the city. One of the others was Christopher Wren, a lifelong friend. In this role Hooke was responsible for the design of several buildings, including the Monument. Nichols writes about all these activities, as well as Hooke's childhood, his education at Westminster School, the University of Oxford when Hooke was an undergraduate, and the founding of the Royal Society. The book draws on research for a master's degree. Turning a dissertation into a popular book is risky. The author has avoided the pitfall of making it too academic, but the result is not satisfying. Nichols seems overawed by Hooke and his work, frequently seeming to credit Hooke with a far-reaching influence that he did not necessarily have. There may be a case for lauding Hooke as the father of English microscopy, the father of English meteorology, and the founder of English geology and earth sciences, but it needs to be made much more critically, even in a popular work. Hooke was full of good ideas, but he rarely continued long enough to put them into practice. There is no doubt that Hooke proposed using a balance wheel and spring to improve the timekeeping of a watch, for example, but he did not have a watch made to his design until after Christiaan Huygens had

  15. High temperature strain measurement with a resistance strain gage

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen; Fichtel, ED; Mcdaniel, Amos

    1993-01-01

    A PdCr based electrical resistance strain gage was demonstrated in the laboratory to be a viable sensor candidate for static strain measurement at high temperatures. However, difficulties were encountered while transferring the sensor to field applications. This paper is therefore prepared for recognition and resolution of the problems likely to be encountered with PdCr strain gages in field applications. Errors caused by the measurement system, installation technique and lead wire attachment are discussed. The limitations and some considerations related to the temperature compensation technique used for this gage are also addressed.

  16. Cost effectiveness of the stream-gaging program in northeastern California

    USGS Publications Warehouse

    Hoffard, S.H.; Pearce, V.F.; Tasker, Gary D.; Doyle, W.H.

    1984-01-01

    Results are documented of a study of the cost effectiveness of the stream-gaging program in northeastern California. Data uses and funding sources were identified for the 127 continuous stream gages currently being operated in the study area. One stream gage was found to have insufficient data use to warrant cooperative Federal funding. Flow-routing and multiple-regression models were used to simulate flows at selected gaging stations. The models may be sufficiently accurate to replace two of the stations. The average standard error of estimate of streamflow records is 12.9 percent. This overall level of accuracy could be reduced to 12.0 percent using computer-recommended service routes and visit frequencies. (USGS)

  17. Cost-effectiveness of the stream-gaging program in the Hawaii District

    USGS Publications Warehouse

    Matsuoka, I.; Lee, R.; Thomas, W.O.

    1985-01-01

    This project documents the results of a study of the cost-effectiveness of the stream-gaging program in the Hawaii District. The stream gages in the District were divided into two groups, the State of Hawaii and the Other Pacific Areas. Data uses and funding sources were identified for the 124 continuous stream gages currently being operated in the Hawaii District with a budget of $570,620. All the stream-gages were identified as having sufficient reason to continue their operation and they should be maintained in the program for the foreseeable future. (USGS)

  18. Fish-hook injuries: a risk for fishermen

    PubMed Central

    2010-01-01

    Fishing is one of the best known and practiced human activities. However, you should remember that, when casting the hook from the riverbank or grasping it to add bait, fishermen run a real risk of injury if the hook punctures the skin. Briefly we describe a case where a young, 32-year-old fisherman who was reeling the hook back to shore when it hit him in the face and embedded itself in his upper eyelid. Upon examination, the eye was found to be unharmed and the hook was removed through a small incision and the aid of a local anesthetic. In the light of this case report, we think it a good idea to advise our friends and patients who we know to be fishermen to wear some form of eye protection as a precaution. PMID:21156039

  19. Practical approaches for application of resistance type strain gages on high temperature composites

    NASA Technical Reports Server (NTRS)

    Moore, Thomas C., Sr.

    1991-01-01

    Four major areas of interest with respect to utilizing strain gages on carbon/carbon (with SiC surfaces) and titanium matrix composites are addressed. Strain gage and adhesive combinations on carbon/carbon (C/C) at temperatures from minus 190 C to to 540 C, half-bridge gaging for reducing apparent strain on C/C using Poisson's ratio and bending configurations, a review of the 'field installation' techniques developed for gaging a C/C hypersonic generic elevon, and results of initial strain gaging efforts on titanium matrix composites are discussed. Current research in developing techniques for increasing the maximum temperature for strain gages on carbon/carbon are reviewed.

  20. Evaluation of Pd-Cr Wires for Strain Gage Application

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen; Greer, L. C., III; Oberle, L. G.

    1995-01-01

    A newly developed alloy, palladium-13 weight percent chromium (Pd13Cr), was identified by United Technologies Research Center under a NASA contract to be the best material for high temperature strain gage applications. An electrical resistance strain gage that can provide accurate static strain measurement to a temperature higher than that of a commercially available gage is urgently needed in aerospace and aeronautics research. A strain gage made of a 25.4 micron (1 mil) diameter Pd13Cr wire has been recently demonstrated to be usable for static strain measurements to 800 C. This compares to the 400 C temperature limit of the commercially available strain gages. The performance of the Pd-Cr gage, however, strongly depends on the quality of the Pd13Cr wire. Four batches of Pd-Cr wires purchased from three different manufacturers were therefore evaluated to determine the best source of the wire for strain gage applications. The three suppliers were Precious Metal Institute in China, Sigmund Cohn Co., and G & S Titanium, Inc. in the United States. Two batches of wires obtained from Previous Metal Institute in 1987 and 1992, respectively are referred to herein as China87 and China92 wires. The mechanical, chemical and electrical properties of these wires, both as-received and after high temperature exposures at 800 C for 50 hours were analyzed. The elastic modulus and the failure strength of the wires were evaluated using a tensile test machine equipped with a laser speckle strain measurement system. The chemical and microstructural properties of the wires were inspected using a plasma atomic emission spectrometer and a scanning electron microscope (SEM) equipped with an energy dispersive X-ray spectroscope (EDS). The electrical stability and repeatability of the wires were determined by measuring the electrical resistance of the wires during three thermal cycles to 1000 C and a ten-hour soak at 1000 C. As a result of this study, the wire which has the highest

  1. Influence of Primary Gage Sensitivities on the Convergence of Balance Load Iterations

    NASA Technical Reports Server (NTRS)

    Ulbrich, Norbert Manfred

    2012-01-01

    The connection between the convergence of wind tunnel balance load iterations and the existence of the primary gage sensitivities of a balance is discussed. First, basic elements of two load iteration equations that the iterative method uses in combination with results of a calibration data analysis for the prediction of balance loads are reviewed. Then, the connection between the primary gage sensitivities, the load format, the gage output format, and the convergence characteristics of the load iteration equation choices is investigated. A new criterion is also introduced that may be used to objectively determine if the primary gage sensitivity of a balance gage exists. Then, it is shown that both load iteration equations will converge as long as a suitable regression model is used for the analysis of the balance calibration data, the combined influence of non linear terms of the regression model is very small, and the primary gage sensitivities of all balance gages exist. The last requirement is fulfilled, e.g., if force balance calibration data is analyzed in force balance format. Finally, it is demonstrated that only one of the two load iteration equation choices, i.e., the iteration equation used by the primary load iteration method, converges if one or more primary gage sensitivities are missing. This situation may occur, e.g., if force balance calibration data is analyzed in direct read format using the original gage outputs. Data from the calibration of a six component force balance is used to illustrate the connection between the convergence of the load iteration equation choices and the existence of the primary gage sensitivities.

  2. Optical ablation/temperature gage (COTA)

    NASA Astrophysics Data System (ADS)

    Cassaing, J.; Balageas, D.

    ONERA has ground and flight tested for heat-shield recession a novel technique, different from current radiation and acoustic measurement methods. It uses a combined ablation/temperature gage that views the radiation optically from a cavity embedded within the heat shield. Flight measurements, both of temperature and of passage of the ablation front, are compared with data generated by a predictive numerical code. The ablation and heat diffusion into the instrumented ablator can be simulated numerically to evaluate accurately the errors due to the presence of the gage. This technology was established in 1978 and finally adopted after ground tests in arc heater facilities. After four years of flight evaluations, it is possible to evaluate and criticize the sensor reliability.

  3. Robert Hooke's model of memory.

    PubMed

    Hintzman, Douglas L

    2003-03-01

    In 1682 the scientist and inventor Robert Hooke read a lecture to the Royal Society of London, in which he described a mechanistic model of human memory. Yet few psychologists today seem to have heard of Hooke's memory model. The lecture addressed questions of encoding, memory capacity, repetition, retrieval, and forgetting--some of these in a surprisingly modern way. Hooke's model shares several characteristics with the theory of Richard Semon, which came more than 200 years later, but it is more complete. Among the model's interesting properties are that (1) it allows for attention and other top-down influences on encoding; (2) it uses resonance to implement parallel, cue-dependent retrieval; (3) it explains memory for recency; (4) it offers a single-system account of repetition priming; and (5) the power law of forgetting can be derived from the model's assumptions in a straightforward way.

  4. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  5. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  6. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  7. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  8. 49 CFR 213.143 - Frog guard rails and guard faces; gage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Frog guard rails and guard faces; gage. 213.143... and guard faces; gage. The guard check and guard face gages in frogs shall be within the limits... frog to the guard line 1 of its guard rail or guarding face, measured across the track at right angles...

  9. Hooking Up and Identity Development of Female College Students

    ERIC Educational Resources Information Center

    Kooyman, Leslie; Pierce, Gloria; Zavadil, Amy

    2011-01-01

    Hooking up generally involves casual sex with noncommittal partners. Hooking up is prevalent on college campuses today and can negatively affect the identity development of female students. The authors examined this phenomenon with a feminist developmental perspective, evaluating hooking up in the context of sexual risk taking with physical and…

  10. Palladium-chromium static strain gage for high temperature propulsion systems

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen

    1991-01-01

    The present electrical strain gage for high temperature static strain measurements is in its fine-wire and thin-film forms designed to be temperature-compensated on any substrate material. The gage element is of Pd-Cr alloy, while the compensator is of Pt. Because the thermally-induced apparent strain of this compensated wire strain gage is sufficiently small, with good reproducibility between thermal cycles to 800 C, output figures can be corrected within a reasonable margin of error.

  11. Gage for micromachining system

    DOEpatents

    Miller, Donald M.

    1979-02-27

    A gage for measuring the contour of the surface of an element of a micromachining tool system and of a work piece machined by the micromachining tool system. The gage comprises a glass plate containing two electrical contacts and supporting a steel ball resting against the contacts. As the element or workpiece is moved against the steel ball, the very slight contact pressure causes an extremely small movement of the steel ball which breaks the electrical circuit between the two contacts. The contour information is supplied to a dedicated computer controlling the micromachining tool so that the computer knows the contour of the element and the work piece to an accuracy of .+-. 25 nm. The micromachining tool system with X- and omega-axes is used to machine spherical, aspherical, and irregular surfaces with a maximum contour error of 100 nanometers (nm) and surface waviness of no more than 0.8 nm RMS.

  12. Comparison of thin-film resistance heat-transfer gages with thin-skin transient calorimeter gages in conventional hypersonic wind tunnels

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III

    1981-01-01

    Thin film gages deposited at the stagnation region of small (8.1-mm-diameter) hemispheres and gages mounted flush with the surface of a sharp-leading-edge flat plate were tested in the Langley continuous-flow hypersonic tunnel and in the Langley hypersonic CF4 tunnel. Two substrate materials were tested, quartz and a machinable glass-ceramic. Small hemispheres were also tested utilizing the thin-skin transient calorimeter technique usually employed in conventional tunnels. One transient calorimeter model was a thin shell of stainless steel, and the other was a thin-skin insert of stainless steel mounted into a hemisphere fabricated from a machinable-glass-ceramic. Measured heat-transfer rates from the various hemispheres were compared with one another and with predicted rates. The results demonstrate the feasibility and advantages of using-film resistance heat-transfer gages in conventional hypersonic wind tunnels over a wide range of conditions.

  13. Cost-effectiveness of the U.S. Geological Survey stream-gaging program in Indiana

    USGS Publications Warehouse

    Stewart, J.A.; Miller, R.L.; Butch, G.K.

    1986-01-01

    Analysis of the stream gaging program in Indiana was divided into three phases. The first phase involved collecting information concerning the data need and the funding source for each of the 173 surface water stations in Indiana. The second phase used alternate methods to produce streamflow records at selected sites. Statistical models were used to generate stream flow data for three gaging stations. In addition, flow routing models were used at two of the sites. Daily discharges produced from models did not meet the established accuracy criteria and, therefore, these methods should not replace stream gaging procedures at those gaging stations. The third phase of the study determined the uncertainty of the rating and the error at individual gaging stations, and optimized travel routes and frequency of visits to gaging stations. The annual budget, in 1983 dollars, for operating the stream gaging program in Indiana is $823,000. The average standard error of instantaneous discharge for all continuous record gaging stations is 25.3%. A budget of $800,000 could maintain this level of accuracy if stream gaging stations were visited according to phase III results. A minimum budget of $790,000 is required to operate the gaging network. At this budget, the average standard error of instantaneous discharge would be 27.7%. A maximum budget of $1 ,000,000 was simulated in the analysis and the average standard error of instantaneous discharge was reduced to 16.8%. (Author 's abstract)

  14. Cost effectiveness of the US Geological Survey's stream-gaging program in New York

    USGS Publications Warehouse

    Wolcott, S.W.; Gannon, W.B.; Johnston, W.H.

    1986-01-01

    The U.S. Geological Survey conducted a 5-year nationwide analysis to define and document the most cost effective means of obtaining streamflow data. This report describes the stream gaging network in New York and documents the cost effectiveness of its operation; it also identifies data uses and funding sources for the 174 continuous-record stream gages currently operated (1983). Those gages as well as 189 crest-stage, stage-only, and groundwater gages are operated with a budget of $1.068 million. One gaging station was identified as having insufficient reason for continuous operation and was converted to a crest-stage gage. Current operation of the 363-station program requires a budget of $1.068 million/yr. The average standard error of estimation of continuous streamflow data is 13.4%. Results indicate that this degree of accuracy could be maintained with a budget of approximately $1.006 million if the gaging resources were redistributed among the gages. The average standard error for 174 stations was calculated for five hypothetical budgets. A minimum budget of $970,000 would be needed to operated the 363-gage program; a budget less than this does not permit proper servicing and maintenance of the gages and recorders. Under the restrictions of a minimum budget, the average standard error would be 16.0%. The maximum budget analyzed was $1.2 million, which would decrease the average standard error to 9.4%. (Author 's abstract)

  15. High temperature strain gage technology for gas turbine engines

    NASA Technical Reports Server (NTRS)

    Fichtel, Edward J.; Mcdaniel, Amos D.

    1994-01-01

    This report summarizes the results of a six month study that addressed specific issues to transfer the Pd-13Cr static strain sensor to a gas turbine engine environment. The application issues that were addressed include: (1) evaluation of a miniature, variable potentiometer for use as the ballast resistor, in conjunction with a conventional strain gage signal conditioning unit; (2) evaluation of a metal sheathed, platinum conductor leadwire assembly for use with the three-wire sensor; and (3) subjecting the sensor to dynamic strain cyclic testing to determine fatigue characteristics. Results indicate a useful static strain gage system at all temperature levels up to 1350 F. The fatigue characteristics also appear to be very promising, indicating a potential use in dynamic strain measurement applications. The procedure, set-up, and data for all tests are presented in this report. This report also discusses the specific strain gage installation technique for the Pd-13Cr gage because of its potential impact on the quality of the output data.

  16. Differences between nipher and slter shielded rain gages at two Colorado deposition monitoring sites

    USGS Publications Warehouse

    Bigelow, David S.; Denning, A. Scott

    1990-01-01

    In the last decade the United States and Canada have made significant progress in establishing spatial ad temporal estimates of atmospheric deposition throughout North America. Fundamental to the wet-deposition portion of these estimates is the accurate and precise measurement of precipitation amount. Goodison and others (I-3) have reported on a new type of shielded snow gage known as the Canadian MSC Nipher shielded snow gage. Because this shielded snow gage has been shown to be superior to other precipitation gages for the estimation of snowfall amount, its design was adapted to the Universal Belfort precipitation gage (4), the dominant precipitation gage used at deposition monitoring sites in the United States. Favorable results taken from monitoring sites using this modified Nipher shielded snow gage (3-6) have prompted the U.S. Environmental Protection Agency and the Electric Power Research Institute to adopt the Nipher shielded Belfort gage as a standard piece of equipment in the Acid MODES and Operational Evaluation Network (OEN) monitoring programs and to propose that is be included as a standard snow gage in other North American deposition monitoring programs. This communication details preliminary results from two of nine NADP/NTN deposition monitoring sites selected by the Environmental Protection Agency to compare Nipher shielded Belfort precipitation gage volumes to volumes obtained from the standard Belfort gage used in the NADP/NTN monitoring program.

  17. Estimating freshwater turtle mortality rates and population declines following hook ingestion.

    PubMed

    Steen, David A; Robinson, Orin J

    2017-12-01

    Freshwater turtle populations are susceptible to declines following small increases in the mortality of adults, making it essential to identify and understand potential threats. Freshwater turtles ingest fish hooks associated with recreational angling, and this is likely a problem because hook ingestion is a source of additive mortality for sea turtles. We used a Bayesian-modeling framework, observed rates of hook ingestion by freshwater turtles, and mortality of sea turtles from hook ingestion to examine the probability that a freshwater turtle in a given population ingests a hook and subsequently dies from it. We used the results of these analyses and previously published life-history data to simulate the effects of hook ingestion on population growth for 3 species of freshwater turtle. In our simulation, the probability that an individual turtle ingests a hook and dies as a result was 1.2-11%. Our simulation results suggest that this rate of mortality from hook ingestion is sufficient to cause population declines. We believe we have identified fish-hook ingestion as a serious yet generally overlooked threat to the viability of freshwater turtle populations. © 2017 Society for Conservation Biology.

  18. Application of Temperature Sensitivities During Iterative Strain-Gage Balance Calibration Analysis

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.

    2011-01-01

    A new method is discussed that may be used to correct wind tunnel strain-gage balance load predictions for the influence of residual temperature effects at the location of the strain-gages. The method was designed for the iterative analysis technique that is used in the aerospace testing community to predict balance loads from strain-gage outputs during a wind tunnel test. The new method implicitly applies temperature corrections to the gage outputs during the load iteration process. Therefore, it can use uncorrected gage outputs directly as input for the load calculations. The new method is applied in several steps. First, balance calibration data is analyzed in the usual manner assuming that the balance temperature was kept constant during the calibration. Then, the temperature difference relative to the calibration temperature is introduced as a new independent variable for each strain--gage output. Therefore, sensors must exist near the strain--gages so that the required temperature differences can be measured during the wind tunnel test. In addition, the format of the regression coefficient matrix needs to be extended so that it can support the new independent variables. In the next step, the extended regression coefficient matrix of the original calibration data is modified by using the manufacturer specified temperature sensitivity of each strain--gage as the regression coefficient of the corresponding temperature difference variable. Finally, the modified regression coefficient matrix is converted to a data reduction matrix that the iterative analysis technique needs for the calculation of balance loads. Original calibration data and modified check load data of NASA's MC60D balance are used to illustrate the new method.

  19. Development of Displacement Gages Exposed to Solid Rocket Motor Internal Environments

    NASA Technical Reports Server (NTRS)

    Bolton, D. E.; Cook, D. J.

    2003-01-01

    The Space Shuttle Reusable Solid Rocket Motor (RSRM) has three non-vented segment-to-segment case field joints. These joints use an interference fit J-joint that is bonded at assembly with a Pressure Sensitive Adhesive (PSA) inboard of redundant O-ring seals. Full-scale motor and sub-scale test article experience has shown that the ability to preclude gas leakage past the J-joint is a function of PSA type, joint moisture from pre-assembly humidity exposure, and the magnitude of joint displacement during motor operation. To more accurately determine the axial displacements at the J-joints, two thermally durable displacement gages (one mechanical and one electrical) were designed and developed. The mechanical displacement gage concept was generated first as a non-electrical, self-contained gage to capture the maximum magnitude of the J-joint motion. When it became feasible, the electrical displacement gage concept was generated second as a real-time linear displacement gage. Both of these gages were refined in development testing that included hot internal solid rocket motor environments and simulated vibration environments. As a result of this gage development effort, joint motions have been measured in static fired RSRM J-joints where intentional venting was produced (Flight Support Motor #8, FSM-8) and nominal non-vented behavior occurred (FSM-9 and FSM-10). This data gives new insight into the nominal characteristics of the three case J-joint positions (forward, center and aft) and characteristics of some case J-joints that became vented during motor operation. The data supports previous structural model predictions. These gages will also be useful in evaluating J-joint motion differences in a five-segment Space Shuttle solid rocket motor.

  20. Cut-it-out technique for ocular fish-hook injury.

    PubMed

    Ahmad, Syed Shoeb; Seng, Chiang Wai; Ghani, Shuaibah Abdul; Lee, Jane F

    2013-10-01

    An 11-year-old boy was involved in an injury with a fish-hook to his eye. The hook had impaled itself to the cornea and deeper structures. There was associated corneal edema and hyphema, making visualization difficult. In this case, we performed the unusual "cut-it-out" technique to remove the hook from the eye.

  1. In vitro Antioxidant of a Water-Soluble Polysaccharide from Dendrobium fimhriatum Hook.var.oculatum Hook

    PubMed Central

    Luo, Aoxue; Fan, Yijun

    2011-01-01

    A water-soluble crude polysaccharide (DFHP) obtained from the aqueous extracts of the stem of Dendrobium fimhriatum Hook.var.oculatum Hook through hot water extraction followed by ethanol precipitation, was found to have an average molecular weight (Mw) of about 209.3 kDa. Monosaccharide analysis revealed that DFHP was composed of mannose, glucose and galactose in a content ratio of 37.52%; 43.16%; 19.32%. The investigation of antioxidant activity in vitro showed that DFHP is a potential antioxidant. PMID:21747725

  2. Can hook-bending be let off the hook? Bending/unbending of pliant tools by cockatoos.

    PubMed

    Laumer, I B; Bugnyar, T; Reber, S A; Auersperg, A M I

    2017-09-13

    The spontaneous crafting of hook-tools from bendable material to lift a basket out of a vertical tube in corvids has widely been used as one of the prime examples of animal tool innovation. However, it was recently suggested that the animals' solution was hardly innovative but strongly influenced by predispositions from habitual tool use and nest building. We tested Goffin's cockatoo, which is neither a specialized tool user nor a nest builder, on a similar task set-up. Three birds individually learned to bend hook tools from straight wire to retrieve food from vertical tubes and four subjects unbent wire to retrieve food from horizontal tubes. Pre-experience with ready-made hooks had some effect but was not necessary for success. Our results indicate that the ability to represent and manufacture tools according to a current need does not require genetically hardwired behavioural routines, but can indeed arise innovatively from domain general cognitive processing. © 2017 The Authors.

  3. High temperature static strain measurement with an electrical resistance strain gage

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen

    1992-01-01

    An electrical resistance strain gage that can supply accurate static strain measurement for NASP application is being developed both in thin film and fine wire forms. This gage is designed to compensate for temperature effects on substrate materials with a wide range of thermal expansion coefficients. Some experimental results of the wire gage tested on one of the NASP structure materials, i.e., titanium matrix composites, are presented.

  4. In-situ shear stress indicator using heated strain gages at the flow boundary

    NASA Astrophysics Data System (ADS)

    Yeh, Chi-An; Yang, Fuling

    2011-11-01

    This work borrows the concept of hot-wire anemometry and sketch a technique that uses local heat transfer to infer the flow field and the corresponding stress. Conventional strain gages were mounted at the flow solid boundary as the heat source and acrylic boundary was chosen for its low thermal conductivity ensuring heat accumulation when a gage is energized. The gage would now work in slightly overheated state and its self-heating leads to an additional thermal strain. When exposed to a flow field, heat is brought away by local forced convection, resulting in deviations in gage signal from that developed in quiescent liquid. We have developed a facility to achieve synchronous gage measurements at different locations on a solid boundary. Three steady flow motions were considered: circular Couette flow, rectilinear uniform flow, and rectilinear oscillating flow. Preliminary tests show the gage reading does respond to the imposed flow through thermal effects and greater deviation was measured in flows of higher shear strain rates. The correlation between the gage signals and the imposed flow field is further examined by theoretical analysis. We also introduced a second solid boundary to the vicinity of the gage in the two rectilinear flows. The gage readings demonstrate rises in its magnitudes indicating wall amplification effect on the local shear strain, agreeing to the drag augmentation by a second solid boundary reported in many multiphase flow literatures.

  5. Dark Circles under Eyes

    MedlinePlus

    Symptoms Dark circles under eyes By Mayo Clinic Staff Dark circles under your eyes generally implies that the darkening ... eye. Fatigue is the most common cause of dark circles under your eyes. Sometimes, what appear to ...

  6. Ethylene Is Not Responsible for Phytochrome-Mediated Apical Hook Exaggeration in Tomato

    PubMed Central

    Takahashi-Asami, Miki; Shichijo, Chizuko; Tsurumi, Seiji; Hashimoto, Tohru

    2016-01-01

    The apical hook of tomato seedlings is exaggerated by phytochrome actions, while in other species such as bean, pea and Arabidopsis, the hook is exaggerated by ethylene and opens by phytochrome actions. The present study was aimed to clarify mainly whether ethylene is responsible for the phytochrome-mediated hook exaggeration of tomato seedlings. Dark-grown 5-day-old seedlings were subjected to various ways of ethylene application in the dark as well as under the actions of red (R) or far-red light (FR). The ethylene emitted by seedlings was also quantified relative to hook exaggeration. The results show: Ambient ethylene, up-to about 1.0 μL L-1, suppressed (opened) the hooks formed in the dark as well as the ones exaggerated by R or FR, while at 3.0–10 μL L-1 it enhanced (closed) the hook only slightly as compared with the most-suppressed level at about 1.0 μL L-1. Treatment with 1-aminocyclopropane-1-carboxylic acid (ACC), the immediate precursor of ethylene biosynthesis, did not enhance the hook, only mimicking the suppressive effects of ambient ethylene. The biosynthesis inhibitor, CoCl2 or aminoethoxyvinylglycine, enhanced hook curvature, and the enhancement was canceled by supplement of ethylene below 1.0 μL L-1. Auxin transport inhibitor, N-1-naphthylphthalamic acid, by contrast, suppressed curvature markedly without altering ethylene emission. The effects of the above-stated treatments did not differentiate qualitatively among the R-, FR-irradiated seedlings and dark control so as to explain phytochrome-mediated hook exaggeration. In addition, ethylene emission by seedlings was affected neither by R nor FR at such fluences as to cause hook exaggeration. In conclusion, (1) ethylene suppresses not only the light-exaggerated hook, but also the dark-formed one; (2) ethylene emission is not affected by R or FR, and also not correlated with the hook exaggerations; thus ethylene is not responsible for the hook exaggeration in tomato; and (3) auxin is

  7. Classification by causes of dark circles and appropriate evaluation method of dark circles.

    PubMed

    Park, S R; Kim, H J; Park, H K; Kim, J Y; Kim, N S; Byun, K S; Moon, T K; Byun, J W; Moon, J H; Choi, G S

    2016-08-01

    Dark circles refer to a symptom that present darkness under the eyes. Because of improvement in the quality of life, the dark circles have been recognized as one of major cosmetic concerns. However, it is not easy to classify the dark circles because they have various causes. To select suitable instruments and detailed evaluation items, the dark circles were classified according to the causes through visual assessment, Wood's lamp test, and medical history survey for 100 subjects with dark circles. After the classification, were newly recruited for instrument conformity assessment. Through this, suitable instruments for dark circle evaluation were selected. We performed a randomized clinical trial for dark circles, a placebo-controlled double-blind study, using effective parameters of the instruments selected from the preliminary test. Dark circles of vascular type (35%) and mixed type (54%), a combination of pigmented and vascular types, were the most common. Twenty four subjects with the mixed type dark circles applied the test product (Vitamin C 3%, Vitamin A 0.1%, Vitamin E 0.5%) and placebo on randomized split-face for 8 weeks. The effective parameters (L*, a, M.I., E.I., quasi L*, quasi a* and dermal thickness) were measured during the study period. Result showed that the L* value of Chromameter(®) , Melanin index (M.I.) of Mexameter(®) and quasi L* value obtained by image analysis improved with statistical significance after applying the test product compared with the placebo product. We classified the dark circles according to the causes of the dark circles and verified the reliability of the parameter obtained by the instrument conformity assessment used in this study through the efficacy evaluation. Also based on this study, we were to suggest newly established methods which can be applied to the evaluation of efficacy of functional cosmetics for dark circles. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Embedded gage impact study

    NASA Technical Reports Server (NTRS)

    Schramm, S. W.; Daniel, I. M.

    1984-01-01

    Impact damage in graphite/epoxy laminates was characterized and transient strain history during impact was correlated. The material investigated was AS-4/3501-6 graphite/epoxy. Eight-ply and sixteen-ply quasi-isotropic laminates of 45/0/-45/90 sub s and 45/0/-45/90 sub 2s layups were fabricated with strain gages embedded between plies during the strain gages and leads from the highly conductive graphite fibers. The specimens were circular plates 12.7 cm (5 in.) in diameter and clamped along their circumference. The specimens were impacted with a 185 gm impactor, dropped from heights of 1.20 m and 1.65 m. An accelerometer was attached to the back surface of the specimen opposite the impact point and was used to trigger the recording instrumentation. The transient strain data were recorded with an eight channel waveform digitizer capable of sampling data at 0.5 microsec intervals. The data were stored, processed, and plotted by means of a microcomputer. Transient strain data were correlated with results from ultrasonic inspection of the specimens.

  9. Graphical correlation of gaging-station records

    USGS Publications Warehouse

    Searcy, James K.

    1960-01-01

    A gaging-station record is a sample of the rate of flow of a stream at a given site. This sample can be used to estimate the magnitude and distribution of future flows if the record is long enough to be representative of the long-term flow of the stream. The reliability of a short-term record for estimating future flow characteristics can be improved through correlation with a long-term record. Correlation can be either numerical or graphical, but graphical correlation of gaging-station records has several advantages. The graphical correlation method is described in a step-by-step procedure with an illustrative problem of simple correlation, illustrative problems of three examples of multiple correlation--removing seasonal effect--and two examples of correlation of one record with two other records. Except in the problem on removal of seasonal effect, the same group of stations is used in the illustrative problems. The purpose of the problems is to illustrate the method--not to show the improvement that can result from multiple correlation as compared with simple correlation. Hydrologic factors determine whether a usable relation exists between gaging-station records. Statistics is only a tool for evaluating and using an existing relation, and the investigator must be guided by a knowledge of hydrology.

  10. Cost effectiveness of the stream-gaging program in South Carolina

    USGS Publications Warehouse

    Barker, A.C.; Wright, B.C.; Bennett, C.S.

    1985-01-01

    The cost effectiveness of the stream-gaging program in South Carolina was documented for the 1983 water yr. Data uses and funding sources were identified for the 76 continuous stream gages currently being operated in South Carolina. The budget of $422,200 for collecting and analyzing streamflow data also includes the cost of operating stage-only and crest-stage stations. The streamflow records for one stream gage can be determined by alternate, less costly methods, and should be discontinued. The remaining 75 stations should be maintained in the program for the foreseeable future. The current policy for the operation of the 75 stations including the crest-stage and stage-only stations would require a budget of $417,200/yr. The average standard error of estimation of streamflow records is 16.9% for the present budget with missing record included. However, the standard error of estimation would decrease to 8.5% if complete streamflow records could be obtained. It was shown that the average standard error of estimation of 16.9% could be obtained at the 75 sites with a budget of approximately $395,000 if the gaging resources were redistributed among the gages. A minimum budget of $383,500 is required to operate the program; a budget less than this does not permit proper service and maintenance of the gages and recorders. At the minimum budget, the average standard error is 18.6%. The maximum budget analyzed was $850,000, which resulted in an average standard error of 7.6 %. (Author 's abstract)

  11. Circle of influence

    NASA Astrophysics Data System (ADS)

    Robinson, Andrew

    2018-04-01

    The founder of the Vienna Circle – a polymathic and influential group of intellectuals dedicated to the philosophy of science from the late 1920s until the Nazi takeover of Austria in 1938 – was German philosopher and physicist Moritz Schlick. Karl Sigmund's latest book – Exact Thinking in Demented Times: the Vienna Circle and the Epic Quest for the Foundations of Science – tells the story of the Vienna Circle's ideas and personalities.

  12. An electrical strain gage for the tensile testing of paper

    Treesearch

    Douglas M. Jewett

    1963-01-01

    A direct-reading strain gage has been developed at the U.S. Forest Products Laboratory that provides rapid and accurate measurement of the stress - strain properties of paper. The gage, which employs a differential transformer, is particularly suited to servo-operated x-y recorders.

  13. Single-strain-gage force/stiffness buckling prediction techniques on a hat-stiffened panel

    NASA Technical Reports Server (NTRS)

    Hudson, Larry D.; Thompson, Randolph C.

    1991-01-01

    Predicting the buckling characteristics of a test panel is necessary to ensure panel integrity during a test program. A single-strain-gage buckling prediction method was developed on a hat-stiffened, monolithic titanium buckling panel. The method is an adaptation of the original force/stiffness method which requires back-to-back gages. The single-gage method was developed because the test panel did not have back-to-back gages. The method was used to predict buckling loads and temperatures under various heating and loading conditions. The results correlated well with a finite element buckling analysis. The single-gage force/stiffness method was a valid real-time and post-test buckling prediction technique.

  14. Cost effectiveness of stream-gaging program in Michigan

    USGS Publications Warehouse

    Holtschlag, D.J.

    1985-01-01

    This report documents the results of a study of the cost effectiveness of the stream-gaging program in Michigan. Data uses and funding sources were identified for the 129 continuous gaging stations being operated in Michigan as of 1984. One gaging station was identified as having insufficient reason to continue its operation. Several stations were identified for reactivation, should funds become available, because of insufficiencies in the data network. Alternative methods of developing streamflow information based on routing and regression analyses were investigated for 10 stations. However, no station records were reproduced with sufficient accuracy to replace conventional gaging practices. A cost-effectiveness analysis of the data-collection procedure for the ice-free season was conducted using a Kalman-filter analysis. To define missing-record characteristics, cross-correlation coefficients and coefficients of variation were computed at stations on the basis of daily mean discharge. Discharge-measurement data were used to describe the gage/discharge rating stability at each station. The results of the cost-effectiveness analysis for a 9-month ice-free season show that the current policy of visiting most stations on a fixed servicing schedule once every 6 weeks results in an average standard error of 12.1 percent for the current $718,100 budget. By adopting a flexible servicing schedule, the average standard error could be reduced to 11.1 percent. Alternatively, the budget could be reduced to $700,200 while maintaining the current level of accuracy. A minimum budget of $680,200 is needed to operate the 129-gaging-station program; a budget less than this would not permit proper service and maintenance of stations. At the minimum budget, the average standard error would be 14.4 percent. A budget of $789,900 (the maximum analyzed) would result in a decrease in the average standard error to 9.07 percent. Owing to continual changes in the composition of the network

  15. A Pedagogy of Sight: Microscopic Vision in Robert Hooke's "Micrographia"

    ERIC Educational Resources Information Center

    Jack, Jordynn

    2009-01-01

    Robert Hooke's "Micrographia" (1665) holds an important place in the history of scientific visual rhetoric. Hooke's accomplishment lies not only in a stunning array of engravings, but also in a "pedagogy of sight"--a rhetorical framework that instructs readers how to view images in accordance with an ideological or epistemic program. Hooke not…

  16. Sidney Hook's Pragmatic Anti-Communism: Commitment to Democracy as Method

    ERIC Educational Resources Information Center

    Ferriter, Courtney

    2017-01-01

    In recent years, opposition to Communism has emerged as Sidney Hook's central philosophical legacy in the eyes of scholars and historians, who tend to ignore all of Hook's pre-Cold War philosophical contributions. Furthermore, critics who treat Hook's anti-Communism often accuse him of abandoning pragmatism for dogmatism in his later career. In…

  17. Superlattice strain gage

    DOEpatents

    Noel, B.W.; Smith, D.L.; Sinha, D.N.

    1988-06-28

    A strain gage comprising a strained-layer superlattice crystal exhibiting piezoelectric properties is described. A substrate upon which such a strained-layer superlattice crystal has been deposited is attached to an element to be monitored for strain. A light source is focused on the superlattice crystal and the light reflected from, passed through, or emitted from the crystal is gathered and compared with previously obtained optical property data to determine the strain in the element. 8 figs.

  18. Diagnosis and management of hook of hamate fractures.

    PubMed

    Kadar, Assaf; Bishop, Allen T; Suchyta, Marissa A; Moran, Steven L

    2018-06-01

    The purpose of this study was to evaluate the time to diagnosis and management of hook of hamate fractures in an era of advanced imaging. We performed a retrospective study of 51 patients treated for hook of hamate fractures. Patients were sent a quickDASH questionnaire regarding the outcomes of their treatment. Hook of hamate fractures were diagnosed with advanced imaging at a median of 27 days. Clinical findings of hook of hamate tenderness had better sensitivity than carpal tunnel-view radiographs. Nonunion occurred in 24% of patients with non-operative treatment and did not occur in the operative group. Both treatment groups achieved good clinical results, with a grip strength of 80% compared with the non-injured hand and a median quickDASH score of 2. Advanced imaging improved the time to diagnosis and treatment compared to historical case series. Nonunion is common in patients treated non-operatively. IV.

  19. 76 FR 11961 - Safety Zone, Dredging Operations; Delaware River, Marcus Hook, PA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-04

    ...-AA00 Safety Zone, Dredging Operations; Delaware River, Marcus Hook, PA AGENCY: Coast Guard, DHS. ACTION... Delaware River while the Dredge Pullen conducts dredging operations at the Sunoco Marcus Hook docks in the vicinity of the Marcus Hook Range near Marcus Hook, PA. This action is necessary to maintain the 42 ft...

  20. Education as a Practice of Freedom: Reflections on bell hooks

    ERIC Educational Resources Information Center

    Specia, Akello; Osman, Ahmed A.

    2015-01-01

    This paper critically analyses the conceptions of bell hooks on education. It focuses on the relevance of hook's ideas to the classroom. It is a theoretical paper based on secondary data that seeks to contribute to the growing body of knowledge in education. The paper is a reflection of hook's reaction to education as a practice of freedom, the…

  1. Recommended Strain Gage Application Procedures for Various Langley Research Center Balances and Test Articles

    NASA Technical Reports Server (NTRS)

    Moore, Thomas C., Sr.

    1997-01-01

    The NASA Langley Research Center uses more than 10000 strain gages per year in supporting its various research programs. The character of the testing at LaRC is such that the types of strain gage installations, the materials they are applied to, and the test environments encountered, require many varied approaches for installing strain gages. These installations must be accomplished in the most technically discerning and appropriate manner. This technical memorandum is offered as an assisting guide in helping the strain gage user to determine the appropriate approach for a given strain gage application requirement. Specifically, this document offers detailed recommendations for strain gaging the following: LaRC-Designed balances, LARC custom transducers, certain composite materials and alloys, high-temperature test articles, and selected non-typical or unique materials or test conditions.

  2. Newton–Hooke-type symmetry of anisotropic oscillators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, P.M., E-mail: zhpm@impcas.ac.cn; Horvathy, P.A., E-mail: horvathy@lmpt.univ-tours.fr; Laboratoire de Mathématiques et de Physique Théorique, Université de Tours

    2013-06-15

    Rotation-less Newton–Hooke-type symmetry, found recently in the Hill problem, and instrumental for explaining the center-of-mass decomposition, is generalized to an arbitrary anisotropic oscillator in the plane. Conversely, the latter system is shown, by the orbit method, to be the most general one with such a symmetry. Full Newton–Hooke symmetry is recovered in the isotropic case. Star escape from a galaxy is studied as an application. -- Highlights: ► Rotation-less Newton–Hooke (NH) symmetry is generalized to an arbitrary anisotropic oscillator. ► The orbit method is used to find the most general case for rotation-less NH symmetry. ► The NH symmetry ismore » decomposed into Heisenberg algebras based on chiral decomposition.« less

  3. High-Temperature Extensometry and PdCr Temperature-Compensated Wire Resistance Strain Gages Compared

    NASA Technical Reports Server (NTRS)

    1997-01-01

    A detailed experimental evaluation is underway at the NASA Lewis Research Center to compare and contrast the performance of the PdCr/Pt dual-element temperature-compensated wire resistance strain gage with that of conventional high-temperature extensometry. The advanced PdCr gage, developed by researchers at Lewis, exhibits desirable properties and a relatively small and repeatable apparent strain to 800 C. This gage represents a significant advance in technology because existing commercial resistance strain gages are not reliable for quasi-static strain measurements above approx. 400 C. Various thermal and mechanical loading spectra are being applied by a high-temperature thermomechanical uniaxial testing system to evaluate the two strain-measurement systems. This is being done not only to compare and contrast the two strain sensors, but also to investigate the applicability of the PdCr strain gage to the coupon-level specimen testing environment typically employed when the high-temperature mechanical behavior of structural materials is characterized. Strain measurement capabilities to 800 C are being investigated with a nickel-base superalloy, Inconel 100 (IN 100), substrate material and application to TMC's is being examined with the model system, SCS-6/Ti-15-3. Furthermore, two gage application techniques are being investigated in the comparison study: namely, flame-sprayed and spot welding. The apparent strain responses of both the weldable and flame-sprayed PdCr wire strain gages were found to be cyclically repeatable on both IN 100 and SCS-6/Ti-15-3 [0]_8. In general, each gage exhibited some uniqueness with respect to apparent strain behavior. Gages mounted on the IN 100 specimens tended to show a repeatable apparent strain within the first few cycles, because the thermal response of IN 100 was stable. This was not the case, however, for the TMC specimens, which typically required several thermal cycles to stabilize the thermal strain response. Thus

  4. Making Morning Circle Meaningful

    ERIC Educational Resources Information Center

    Bruce, Susan; Fasy, Cara; Gulick, Jessica; Jones, Jill; Pike, Elizabeth

    2006-01-01

    Morning Circle, also known as Morning Meeting, is often a daily lesson in both general education and special education classrooms. The primary purpose of the Circle is to support each child to establish membership in the class while developing a classroom community and culture. The Responsive Classroom Approach recommends four Circle components:…

  5. 77 FR 67303 - Fisheries of the Caribbean, Gulf of Mexico, and South Atlantic; Reef Fish Fishery of the Gulf of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ... starting in 2005, well before the circle hook requirement went into effect on June 1, 2008. Therefore... assessment did not vary by much, suggesting the change to circle hooks has had little effect on gray... by the Gulf of Mexico Fishery Management Council (Council). The intended effect of this temporary...

  6. Hook2 is involved in the morphogenesis of the primary cilium

    PubMed Central

    Baron Gaillard, Carole L.; Pallesi-Pocachard, Emilie; Massey-Harroche, Dominique; Richard, Fabrice; Arsanto, Jean-Pierre; Chauvin, Jean-Paul; Lecine, Patrick; Krämer, Helmut; Borg, Jean-Paul; Le Bivic, André

    2011-01-01

    Primary cilia originate from the centrosome and play essential roles in several cellular, developmental, and pathological processes, but the underlying mechanisms of ciliogenesis are not fully understood. Given the involvement of the adaptor protein Hook2 in centrosomal homeostasis and protein transport to pericentrosomal aggresomes, we explored its role in ciliogenesis. We found that in human retinal epithelial cells, Hook2 localizes at the Golgi apparatus and centrosome/basal body, a strategic partitioning for ciliogenesis. Of importance, Hook2 depletion disrupts ciliogenesis at a stage before the formation of the ciliary vesicle at the distal tip of the mother centriole. Using two hybrid and immunoprecipitation assays and a small interfering RNA strategy, we found that Hook2 interacts with and stabilizes pericentriolar material protein 1 (PCM1), which was reported to be essential for the recruitment of Rab8a, a GTPase that is believed to be crucial for membrane transport to the primary cilium. Of interest, GFP::Rab8a coimmunoprecipitates with endogenous Hook2 and PCM1. Finally, GFP::Rab8a can overcome Hook2 depletion, demonstrating a functional interaction between Hook2 and these two important regulators of ciliogenesis. The data indicate that Hook2 interacts with PCM1 in a complex that also contains Rab8a and regulates a limiting step required for further initiation of ciliogenesis after centriole maturation. PMID:21998199

  7. The ALE/GAGE/AGAGE Network (DB1001)

    DOE Data Explorer

    Prinn, Ronald G. [MIT, Center for Global Change Science; Weiss, Ray F. [University of California, San Diego; Scripps Institution of Oceanography; Krummel, Paul B. [CSIRO Oceans and Atmosphere, Cape Grim; O'Doherty, Simon [University of Bristol, Barbados and Mace Head Stations; Fraser, Paul [CSIRO Oceans and Atmosphere; Muhle, Jens [UCSD Scripps Institution of Oceanography; Cape Matatula Station; Reimann, Stefan [Swiss Federal Laboratories for Materials Science and Research (EMPA); Jungfraujoch Station; Vollmer, Martin [Swiss Federal Laboratories for Materials Science and Research (EMPA); Jungfraujoch Station; Simmonds, Peter G. [University of Bristol, Atmospheric Chemistry Research Group; Mace Head Station; Malone, Michela [University of Urbino; Monte Cimone Station; Arduini, Jgor [University of Urbino; Monte Cimone Station; Lunder, Chris [Norwegian Institute for Air Research; Ny Alesund Station; Hermansen, Ove [Norwegian Inst. for Air Research (NILU), Kjeller (Norway); Ny Alesund Station; Schmidbauer, Norbert [Norwegian Inst. for Air Research (NILU), Kjeller (Norway); Global Network; Young, Dickon [University of Bristol; Ragged Point Station; Wang, Hsiang J. (Ray) [Geogia Institute of Technology, School of Earth and Atmospheric Sciences; Global Network; Huang, Jin; Rigby, Matthew [University of Bristol; Global Network; Harth, Chris [UCSD, Scripps Institutioon of Oceanography; Global Network; Salameh, Peter [UCSD, Scripps Institution of Oceanography; Global Network; Spain, Gerard [National University of Ireland; Global Network; Steele, Paul [CSIRO Oceans and Atmosphere; Global Network; Arnold, Tim; Kim, Jooil [UCSD, Scripps Institution of Oceanography; Global Network; Derek, Nada; mitrevski, Blagoj; Langenfelds, Ray

    2008-01-01

    In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. More information may be found at the AGAGE home page: http://agage.eas.gatech.edu/instruments-gcms-medusa.htm.

  8. Hidden Connections between Regression Models of Strain-Gage Balance Calibration Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, Norbert

    2013-01-01

    Hidden connections between regression models of wind tunnel strain-gage balance calibration data are investigated. These connections become visible whenever balance calibration data is supplied in its design format and both the Iterative and Non-Iterative Method are used to process the data. First, it is shown how the regression coefficients of the fitted balance loads of a force balance can be approximated by using the corresponding regression coefficients of the fitted strain-gage outputs. Then, data from the manual calibration of the Ames MK40 six-component force balance is chosen to illustrate how estimates of the regression coefficients of the fitted balance loads can be obtained from the regression coefficients of the fitted strain-gage outputs. The study illustrates that load predictions obtained by applying the Iterative or the Non-Iterative Method originate from two related regression solutions of the balance calibration data as long as balance loads are given in the design format of the balance, gage outputs behave highly linear, strict statistical quality metrics are used to assess regression models of the data, and regression model term combinations of the fitted loads and gage outputs can be obtained by a simple variable exchange.

  9. A hot-wire surface gage for skin friction and separation detection measurements

    NASA Technical Reports Server (NTRS)

    Rubesin, M. W.; Okuno, A. F.; Mateer, G. G.; Brosh, A.

    1975-01-01

    A heated-element, skin-friction gage employing a very low thermal conductivity support is described. It is shown that the effective dimension of the gage in the stream direction in only 0.06 mm, including the effects of heat conduction in the supporting material. Because of its small size, the calibration of the gage is independent of the kind of boundary-layer flow (whether laminar or turbulent) and is insensitive to pressure gradients. Construction tolerances can be maintained so that a single universal calibration can be applied. Multiple gages, sufficiently closely spaced so as to interfere with each other, are shown to provide accurate determinations of the locations of the points of boundary-layer separation and reattachment.

  10. Demonstration test of burner liner strain measurements using resistance strain gages

    NASA Technical Reports Server (NTRS)

    Grant, H. P.; Anderson, W. L.

    1984-01-01

    A demonstration test of burner liner strain measurements using resistance strain gages as well as a feasibility test of an optical speckle technique for strain measurement are presented. The strain gage results are reported. Ten Kanthal A-1 wire strain gages were used for low cycle fatigue strain measurements to 950 K and .002 apparent strain on a JT12D burner can in a high pressure (10 atmospheres) burner test. The procedure for use of the strain gages involved extensive precalibration and postcalibration to correct for cooling rate dependence, drift, and temperature effects. Results were repeatable within + or - .0002 to .0006 strain, with best results during fast decels from 950 K. The results agreed with analytical prediction based on an axisymmetric burner model, and results indicated a non-uniform circumferential distribution of axial strain, suggesting temperature streaking.

  11. Hooking-Up, Religiosity, and Sexting Among College Students.

    PubMed

    Hall, Michael; Williams, Ronald D; Ford, M Allison; Cromeans, Erin Murphy; Bergman, Randall J

    2016-07-28

    The purpose of this study was to evaluate the mediation effect of sexting, and taking sexually suggestive photos on religiosity and hooking-up with three separate sexual outcomes. A web-based survey examined the relationship between religiosity and the three hooking-up outcomes among students reporting sexting or taking a sexually suggestive photo in the last 30 days (n = 231). Sexting, as well as taking sexually suggestive photos mediated the relationship between religiosity and hooking-up among females. Sexting may be initiated by females as a way to engage in a nonphysical sexual interaction, which ultimately predisposes them to a physical sexual outcome.

  12. Traffic Circle Model

    DOT National Transportation Integrated Search

    1971-05-01

    The report describes a dynamic model of a traffic circle which has been implemented on a CRT display terminal. The model includes sufficient parameters to allow changes in the structure of the traffic circle, the frequency of traffic introduced to th...

  13. 46 CFR 173.007 - Location of the hook load.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PERTAINING TO VESSEL USE Lifting § 173.007 Location of the hook load. When doing the calculations required in this subpart, the hook load must be considered to be located at the head of the crane. ...

  14. Interactions of light and ethylene in hypocotyl hook maintenance in Arabidopsis thaliana seedlings

    NASA Technical Reports Server (NTRS)

    Knee, E. M.; Hangarter, R. P.; Knee, M.

    2000-01-01

    Etiolated seedlings frequently display a hypocotyl or epicotyl hook which opens on exposure to light. Etylene has been shown to be necessary for maintenance of the hook in a number of plants in darkness. We investigated the interaction of ethylene and light in the regulation of hypocotyl hook opening in Arabidopsis thaliana. We found that hooks of Arabidopsis open in response to continuous red, far-red or blue light in the presence of up to 100 microliters l-1 ethylene. Thus a change in sensitivity to ethylene is likely to be responsible for hook opening in Arabidopsis, rather than a decrease in ethylene production in hook tissues. We used photomorphogenic mutants of Arabidopsis to demonstrate the involvement of both blue light and phytochrome photosensory systems in light-induced hook opening in the presence of ethylene. In addition we used ethylene mutants and inhibitors of ethylene action to investigate the role of ethylene in hook maintenance in seedlings grown in light and darkness.

  15. Elevated-Temperature Tensile-Testing of Foil-Gage Metals

    NASA Technical Reports Server (NTRS)

    Blackburn, L. B.; Ellingsworth, J. R.

    1986-01-01

    Automated system for measuring strain in metal foils at temperatures above 500 degrees F (260 degrees C) uses mechanical extensometer and displacement transducer. System includes counterbalance feature, which eliminates weight contribution of extensometer and reduces grip pressure required for attachment to specimen. Counterbalancing feature overcomes two major difficulties in using extensometers with foil-gage specimens: (1) Weight of extensometer and transducer represents significant fraction of total load applied to specimen and may actually damage it; and (2) grip pressure required for attachment of extensometer to specimens may induce bending stresses in foil-gage materials.

  16. Engineering Evaluation of International Low Impact Docking System Latch Hooks

    NASA Technical Reports Server (NTRS)

    Martinez, J.; Patin, R.; Figert, J.

    2013-01-01

    The international Low Impact Docking System (iLIDS) provides a structural arrangement that allows for visiting vehicles to dock with the International Space Station (ISS) (Fig 1). The iLIDS docking units are mechanically joined together by a series of active and passive latch hooks. In order to preserve docking capability at the existing Russian docking interfaces, the iLIDS latch hooks are required to conform to the existing Russian design. The latch hooks are classified as being fail-safe. Since the latch hooks are fail-safe, the hooks are not fracture critical and a fatigue based service life assessment will satisfy the structural integrity requirements. Constant amplitude fatigue testing to failure on four sets of active/passive iLIDS latch hooks was performed at load magnitudes of 10, 11, and 12 kips. Failure analysis of the hook fatigue failures identified multi-site fatigue initiation that was effectively centered about the hook mid-plane (consistent with the 3D model results). The fatigue crack initiation distribution implies that the fatigue damage accumulation effectively results in a very low aspect ratio surface crack (which can be simulated as thru-thickness crack). Fatigue damage progression resulted in numerous close proximity fatigue crack initiation sites. It was not possible to determine if fatigue crack coalescence occurs during cyclic loading or as result of the fast fracture response. The presence of multiple fatigue crack initiation sites on different planes will result in the formation of ratchet marks as the cracks coalesce. Once the stable fatigue crack becomes unstable and the fast fracture advances across the remaining ligament and the plane stress condition at a free-surface will result in failure along a 45 deg. shear plane (slant fracture) and the resulting inclined edge is called a shear lip. The hook thickness on the plane of fatigue crack initiation is 0.787". The distance between the shear lips on this plane was on the order of 0

  17. Development of buried wire gages for measurement of wall shear stress in Blastane experiments

    NASA Technical Reports Server (NTRS)

    Murthy, S. V.; Steinle, F. W.

    1986-01-01

    Buried Wire Gages operated from a Constant Temperature Anemometer System are among the special types of instrumentation to be used in the Boundary Layer Apparatus for Subsonic and Transonic flow Affected by Noise Environment (BLASTANE). These Gages are of a new type and need to be adapted for specific applications. Methods were developed to fabricate Gage inserts and mount those in the BLASTANE Instrumentation Plugs. A large number of Gages were prepared and operated from a Constant Temperature Anemometer System to derive some of the calibration constants for application to fluid-flow wall shear-stress measurements. The final stage of the calibration was defined, but could not be accomplished because of non-availability of a suitable flow simulating apparatus. This report provides a description of the Buried Wire Gage technique, an explanation of the method evolved for making proper Gages and the calibration constants, namely Temperature Coefficient of Resistance and Conduction Loss Factor.

  18. Dynamic infrared imaging analysis of apical hook development in Arabidopsis: the case of brassinosteroids.

    PubMed

    Smet, Dajo; Žádníková, Petra; Vandenbussche, Filip; Benková, Eva; Van Der Straeten, Dominique

    2014-06-01

    Germination of Arabidopsis seeds in darkness induces apical hook development, based on a tightly regulated differential growth coordinated by a multiple hormone cross-talk. Here, we endeavoured to clarify the function of brassinosteroids (BRs) and cross-talk with ethylene in hook development. An automated infrared imaging system was developed to study the kinetics of hook development in etiolated Arabidopsis seedlings. To ascertain the photomorphogenic control of hook opening, the system was equipped with an automatic light dimmer. We demonstrate that ethylene and BRs are indispensable for hook formation and maintenance. Ethylene regulation of hook formation functions partly through BRs, with BR feedback inhibition of ethylene action. Conversely, BR-mediated extension of hook maintenance functions partly through ethylene. Furthermore, we revealed that a short light pulse is sufficient to induce rapid hook opening. Our dynamic infrared imaging system allows high-resolution, kinetic imaging of up to 112 seedlings in a single experimental run. At this high throughput, it is ideally suited to rapidly gain insight in pathway networks. We demonstrate that BRs and ethylene cooperatively regulate apical hook development in a phase-dependent manner. Furthermore, we show that light is a predominant regulator of hook opening, inhibiting ethylene- and BR-mediated postponement of hook opening. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  19. Improved Regression Analysis of Temperature-Dependent Strain-Gage Balance Calibration Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.

    2015-01-01

    An improved approach is discussed that may be used to directly include first and second order temperature effects in the load prediction algorithm of a wind tunnel strain-gage balance. The improved approach was designed for the Iterative Method that fits strain-gage outputs as a function of calibration loads and uses a load iteration scheme during the wind tunnel test to predict loads from measured gage outputs. The improved approach assumes that the strain-gage balance is at a constant uniform temperature when it is calibrated and used. First, the method introduces a new independent variable for the regression analysis of the balance calibration data. The new variable is designed as the difference between the uniform temperature of the balance and a global reference temperature. This reference temperature should be the primary calibration temperature of the balance so that, if needed, a tare load iteration can be performed. Then, two temperature{dependent terms are included in the regression models of the gage outputs. They are the temperature difference itself and the square of the temperature difference. Simulated temperature{dependent data obtained from Triumph Aerospace's 2013 calibration of NASA's ARC-30K five component semi{span balance is used to illustrate the application of the improved approach.

  20. Strain Gage Signal Interpretation.

    DTIC Science & Technology

    1986-02-01

    blades and vanes in many engines have been collected, played back and examined. The engine types encompass GE’s stable of turbine engines from the small...aeromechanical engineer . 1.3 SUMMARY OF RESULTS Strain gage signals from vibrating rotor blades and vanes were collected, examined, classified, and generalized...turboprops, to turbojets and to the large high bypass turbofan engines . Test conditions include all the phases that are investigated

  1. Cost effectiveness of the U.S. Geological Survey's stream-gaging program in Illinois

    USGS Publications Warehouse

    Mades, D.M.; Oberg, K.A.

    1984-01-01

    Data uses and funding sources were identified for 138 continuous-record discharge-gaging stations currently (1983) operated as part of the stream-gaging program in Illinois. Streamflow data from five of those stations are used only for regional hydrology studies. Most streamflow data are used for defining regional hydrology, defining rainfall-runoff relations, flood forecasting, regulating navigation systems, and water-quality sampling. Based on the evaluations of data use and of alternative methods for determining streamflow in place of stream gaging, no stations in the 1983 stream-gaging program should be deactivated. The current budget (in 1983 dollars) for operating the 138-station program is $768,000 per year. The average standard error of instantaneous discharge for the current practice for visiting the gaging stations is 36.5 percent. Missing stage record accounts for one-third of the 36.5 percent average standard error. (USGS)

  2. Evaluation of submarine strain-gage systems for monitoring coastal sediment migration

    NASA Technical Reports Server (NTRS)

    Shideler, G. L.; Mcgrath, D. G.

    1973-01-01

    Single and multiple strain-gage systems were respectively evaluated as in situ point and areal sensors for monitoring sand-height variations in coastal environments. Static loading tests indicate that gage response pressure is linear for sand heights up to 24 inches. Response pressures are a function of both sand height and aggregate density, with density being influenced by both sediment texture and degree of compaction. Poorer sediment sorting and greater compaction result in higher response pressures. Field tests in a beach foreshore environment indicate that the gage systems are effective qualitative instruments for monitoring long-period migration trends of beach sediments; whereas, short-period responses are not sufficiently reliable. The durability and compactness of the gage systems must be substantially increased for effective field operations. It is recommended that the systems' qualitative potentials be further developed, whereas their development as quantitative instruments be terminated. Further development should emphasize the construction of remote recording systems designed for semipermanent installation.

  3. Levels at Streamflow Gaging Stations--A CD-ROM Based Training Class

    USGS Publications Warehouse

    Nolan, K. Michael; Jacobson, Nathan; Erickson, Robert; Landon, Stanley

    2003-01-01

    Streamgages record the elevation of the water surface above some reference surface, or datum. This datum is assumed to remain unchanged throughout the life of the gage. However, the elevation of gages and their supporting structures often change over time as a result of earthmovement, floods, ice, and debris. The surveying practice of leveling is used to establish datum for new gage structures and to check for vertical movement of those structures over time. Vertical changes in gage structures can affect stage-discharge relations and, thus, could result in incorrect discharge determinations. Datum checks are used to correct stage-discharge relations and allow the USGS to document gage datum throughout the life of a gage. This training presentation describes methods currently used by the U.S. Geological Survey to run levels at gaging stations. The presentation is narrated, but you control the pace of the presentation. If the computer you are using can view 'MPEG' videos you will be able to take advantage of videos found within the presentation. A test, found at the end of the presentation, can be taken to assess how well you understood the training material. The class is registered as class SW1307 with the National Training Center of the U.S. Geologcial Survey. The presentation was developed using Macromedia Director 8.5(1) and is contained in the file 'WRI-4002.exe', which should auto-launch after the CD-ROM is inserted in the PC. The program only runs on a windows-based personal computer (PC). A sound card and speakers are necessary to take advantage of the narration that accompanies the presentation. Text of narrations is provided, if you are unable to listen to the narrations. Instructions for installing and running the presentation are included in the file ' Intro.html'. The file 'Intro.html' is on the CD-ROM containing the presentation and is available from the presentation's help menu.

  4. 75 FR 4265 - Airworthiness Directives; Lifesavings Systems Corp., D-Lok Hook Assembly

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... Airworthiness Directives; Lifesavings Systems Corp., D-Lok Hook Assembly AGENCY: Federal Aviation Administration... adopting a new airworthiness directive (AD) for the Lifesavings Systems Corp., D-Lok Hook assembly... reported surface irregularities and discontinuities on certain D-Lok Hooks because of an unapproved change...

  5. Biomechanical analysis of acromioclavicular joint dislocation treated with clavicle hook plates in different lengths.

    PubMed

    Shih, Cheng-Min; Huang, Kui-Chou; Pan, Chien-Chou; Lee, Cheng-Hung; Su, Kuo-Chih

    2015-11-01

    Clavicle hook plates are frequently used in clinical orthopaedics to treat acromioclavicular joint dislocation. However, patients often exhibit acromion osteolysis and per-implant fracture after undergoing hook plate fixation. With the intent of avoiding future complications or fixation failure after clavicle hook plate fixation, we used finite element analysis (FEA) to investigate the biomechanics of clavicle hook plates of different materials and sizes when used in treating acromioclavicular joint dislocation. Using finite element analysis, this study constructed a model comprising four parts: clavicle, acromion, clavicle hook plate and screws, and used the model to simulate implanting different types of clavicle hook plates in patients with acromioclavicular joint dislocation. Then, the biomechanics of stainless steel and titanium alloy clavicle hook plates containing either six or eight screw holes were investigated. The results indicated that using a longer clavicle hook plate decreased the stress value in the clavicle, and mitigated the force that clavicle hook plates exert on the acromion. Using a clavicle hook plate material characterized by a smaller Young's modulus caused a slight increase in the stress on the clavicle. However, the external force the material imposed on the acromion was less than the force exerted on the clavicle. The findings of this study can serve as a reference to help orthopaedic surgeons select clavicle hook plates.

  6. Gage measures total radiation, including vacuum UV, from ionized high-temperature gases

    NASA Technical Reports Server (NTRS)

    Wood, A. D.

    1969-01-01

    Transient-heat transfer gage measures the total radiation intensity from vacuum ultraviolet and ionized high temperature gases. The gage includes a sensitive piezoelectric crystal that is completely isolated from any ionized flow and vacuum ultraviolet irradiation.

  7. Ceramic Strain Gages for Use at Temperatures up to 1500 Celsius

    NASA Technical Reports Server (NTRS)

    Gregory, Otto; Fralick, Gustave (Technical Monitor)

    2003-01-01

    Indium-tin-oxide (ITO) thin film strain gages were successfully demonstrated at temperatures beyond 1500 C. High temperature static strain tests revealed that the piezoresistive response and electrical stability of the ceramic sensors depended on the thickness of the ITO films comprising the active strain elements. When 2.5 microns-thick ITO films were employed as the active strain elements, the piezoresistive response became unstable at temperatures above 1225 C. In contrast to this, ceramic sensors prepared with 5 microns-thick ITO were stable beyond 1430 C and sensors prepared with 8 microns-thick ITO survived more than 20 hr of operation at 1481 C. Very thick (10 microns) ITo strain gages were extremely stable and responsive at 1528 C. ESCA depth profiles confirmed that an interfacial reaction between the ITO strain gage and alumina substrate was responsible for the high temperature electrical stability observed. Similar improvements in high temperature stability were achieved by doping the active ITO strain elements with aluminum. Several Sic-Sic CMC constant strain beams were instrumented with ITO strain gages and delivered to NASA for testing. Due to the extreme surface roughness of the CMC substrates, new lithography techniques and surface preparation methods were developed. These techniques relied heavily on a combination of Sic and A12O3 cement layers to provide the necessary surface finish for efficient pattern transfer. Micro-contact printing using soft lithography and PDMS stamps was also used to successfully transfer the thin film strain gage patterns to the resist coated CMC substrates. This latter approach has considerable potential for transferring the thin film strain gage patterns to the extremely rough surfaces associated with the CMC's.

  8. Kinematics of Hooke universal joint robot wrists

    NASA Technical Reports Server (NTRS)

    Mckinney, William S., Jr.

    1988-01-01

    The singularity problem associated with wrist mechanisms commonly found on industrial manipulators can be alleviated by redesigning the wrist so that it functions as a three-axis gimbal system. This paper discussess the kinematics of gimbal robot wrists made of one and two Hooke universal joints. Derivations of the resolved rate motion control equations for the single and double Hooke universal joint wrists are presented using the three-axis gimbal system as a theoretical wrist model.

  9. Interdependence of the rad50 hook and globular domain functions.

    PubMed

    Hohl, Marcel; Kochańczyk, Tomasz; Tous, Cristina; Aguilera, Andrés; Krężel, Artur; Petrini, John H J

    2015-02-05

    Rad50 contains a conserved Zn(2+) coordination domain (the Rad50 hook) that functions as a homodimerization interface. Hook ablation phenocopies Rad50 deficiency in all respects. Here, we focused on rad50 mutations flanking the Zn(2+)-coordinating hook cysteines. These mutants impaired hook-mediated dimerization, but recombination between sister chromatids was largely unaffected. This may reflect that cohesin-mediated sister chromatid interactions are sufficient for double-strand break repair. However, Mre11 complex functions specified by the globular domain, including Tel1 (ATM) activation, nonhomologous end joining, and DNA double-strand break end resection were affected, suggesting that dimerization exerts a broad influence on Mre11 complex function. These phenotypes were suppressed by mutations within the coiled-coil and globular ATPase domains, suggesting a model in which conformational changes in the hook and globular domains are transmitted via the extended coils of Rad50. We propose that transmission of spatial information in this manner underlies the regulation of Mre11 complex functions. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Impact gages for detecting meteoroid and other orbital debris impacts on space vehicles.

    NASA Technical Reports Server (NTRS)

    Mastandrea, J. R.; Scherb, M. V.

    1973-01-01

    Impacts on space vehicles have been simulated using the McDonnell Douglas Aerophysics Laboratory (MDAL) Light-Gas Guns to launch particles at hypervelocity speeds into scaled space structures. Using impact gages and a triangulation technique, these impacts have been detected and accurately located. This paper describes in detail the various types of impact gages (piezoelectric PZT-5A, quartz, electret, and off-the-shelf plastics) used. This description includes gage design and experimental results for gages installed on single-walled scaled payload carriers, multiple-walled satellites and space stations, and single-walled full-scale Delta tank structures. A brief description of the triangulation technique, the impact simulation, and the data acquisition system are also included.

  11. Problems Associated with Attaching Strain Gages to Titanium Alloy Ti-61-4V

    NASA Technical Reports Server (NTRS)

    Jenkins, J. M.; Lemcoe, M. M.

    1977-01-01

    Weldable strain gages have shown excellent high temperature characteristics for supersonic cruise aircraft application. The spotwelding attachment method, however, has resulted in serious reductions in the fatigue life of titanium alloy (Ti-6Al-4V) fatigue specimens. The reduction is so severe that the use of weldable strain gages on operational aircraft must be prohibited. The cause of the fatigue problem is thought to be a combination of the microstructure changes in the material caused by spotwelding and the presence of the flange of the stain gage. Brazing, plating, and plasma spraying were investigated as substitutes for spotwelding. The attachment of a flangeless gage by plasma spraying provided the most improvement in the fatigue life of the titanium.

  12. Modeling the hook depth distribution of pelagic longlining in the equatorial area of Indian Ocean

    NASA Astrophysics Data System (ADS)

    Song, Liming; Li, Jie; Gao, Panfeng; Zhou, Ji; Xu, Liuxiong

    2012-12-01

    A survey was conducted in the equatorial area of Indian Ocean for a better understanding of the dynamics of hook depth distribution of pelagic longline fishery. We determined the relationship between hook depth and vertical shear of current coefficiency, wind speed, hook position code, sine of wind angle, sine of angle of attack and weight of messenger weight. We identified the hook depth models by the analysis of covariance with a general linear model. The results showed that the wind effect on the hook depth can be ignored from October to November in the survey area; the surface current effect on the hook depth can be ignored; the equatorial undercurrent is the key factor for the hook depth in Indian Ocean; and there is a negative correlation between the hook depth and vertical shear of current and angle of attack. It was also found that the deeper the hook was set, the higher hook depth shoaling was. The proposed model improves the accuracy of the prediction of hook depth, which can be used to estimate the vertical distribution of pelagic fish in water column.

  13. An economical storage precipitation gage

    Treesearch

    Raymond D. Ratliff; Jack N. Reppert

    1965-01-01

    Describes how to make an economical "can-cone"-type storage precipitation gage, based on one originally designed by the California Department of Water Resources. The cone was modified by including an inner skirt to prevent loss of water between the cone and can. Periodic records of precipitation are obtained by stick measurement. Five complete cones cost $120...

  14. High-Temperature Extensometry and PdCr Temperature-Compensated Wire Resistance Strain Gages Compared

    NASA Technical Reports Server (NTRS)

    1996-01-01

    A detailed experimental evaluation is underway at the NASA Lewis Research Center to compare and contrast the performance of the PdCr/Pt dual-element temperature-compensated wire resistance strain gage with that of conventional high-temperature extensometry. The advanced PdCr gage, developed by researchers at Lewis, exhibits desirable properties and a relatively small and repeatable apparent strain to 800 C. This gage represents a significant advance in technology because existing commercial resistance strain gages are not reliable for quasi-static strain measurements above approximately 400 C. Various thermal and mechanical loading spectra are being applied by a high-temperature thermomechanical uniaxial testing system to evaluate the two strain-measurement systems. This is being done not only to compare and contrast the two strain sensors, but also to investigate the applicability of the PdCr strain gage to the coupon-level specimen testing environment typically employed when the high-temperature mechanical behavior of structural materials is characterized. Strain measurement capabilities to 800 C are being investigated with a nickel-base superalloy, Inconel 100 (IN 100), substrate material and application to TMC's is being examined with the model system, SCS-6/Ti-15-3. Furthermore, two gage application techniques are being investigated in the comparison study: namely, flame-sprayed and spot welding.

  15. The dynamic instability in the hook/flagellum system that triggers bacterial flicks

    NASA Astrophysics Data System (ADS)

    Jabbarzadeh, Mehdi; Fu, Henry

    2017-11-01

    Dynamical bending, buckling, and polymorphic transformations of the flagellum are known to affect bacterial motility, but run-reverse-flick motility of monotrichous bacteria also involves the even more flexible hook, which connects the flagellum to the cell body. Here, we identify the dynamic buckling mechanism that produces flicks in Vibrio alginolyticus. Estimates of forces and torques on the hook from experimental observations suggest that flicks are triggered at stresses below the hook's static Euler buckling criterion. Using an accurate linearization of the Kirchoff rod model for the hook in a model of a swimming bacterium with rigid flagellum, we show that as hook stiffness decreases there is a transition from on-axis flagellar rotation with small hook deflections to flagellar precession with large deflections. When flagellum flexibility is incorporated, the precession is disrupted by significant flagellar bending - i.e., incipient flicks. The predicted onset of dynamic instabilities corresponds well with experimentally observed flick events.

  16. Study on The Geopolymer Concrete Properties Reinforced with Hooked Steel Fiber

    NASA Astrophysics Data System (ADS)

    Abdullah, M. M. A. B.; Tahir, M. F. M.; Tajudin, M. A. F. M. A.; Ekaputri, J. J.; Bayuaji, R.; Khatim, N. A. M.

    2017-11-01

    In this research, Class F fly ash and a mixture of alkaline activators and different amount of hooked steel fiber were used for preparing geopolymer concrete. In order to analyses the effect of hooked steel fiber on the geopolymer concrete, the analysis such as chemical composition of fly ash, workability of fresh geopolymer, water absorption, density, compressive strength of hardened geopolymer concrete have been carried out. Mixtures were prepared with fly ash to alkaline liquid ratio of 2.0 with hooked steel fibers were added to the mix with different amounts which are 1%, 3%, 5% and 7% by the weight of the concrete. Experimental results showed that the compressive strength of geopolymer concrete increases as the hooked steel fibers increases. The optimum compressive strength obtained was up to 87.83 MPa on the 14th day. The density of geopolymer concrete are in the range between 2466 kg/m3 to 2501 kg/m3. In addition, the workability value of geopolymer without hooked steel fibers is 100 mm while the workability value of geopolymer with hooked steel fibers are between 60 mm to 30 mm.

  17. A Model of Differential Growth-Guided Apical Hook Formation in Plants

    PubMed Central

    Žádníková, Petra; Wabnik, Krzysztof; Abuzeineh, Anas; Prusinkiewicz, Przemysław

    2016-01-01

    Differential cell growth enables flexible organ bending in the presence of environmental signals such as light or gravity. A prominent example of the developmental processes based on differential cell growth is the formation of the apical hook that protects the fragile shoot apical meristem when it breaks through the soil during germination. Here, we combined in silico and in vivo approaches to identify a minimal mechanism producing auxin gradient-guided differential growth during the establishment of the apical hook in the model plant Arabidopsis thaliana. Computer simulation models based on experimental data demonstrate that asymmetric expression of the PIN-FORMED auxin efflux carrier at the concave (inner) versus convex (outer) side of the hook suffices to establish an auxin maximum in the epidermis at the concave side of the apical hook. Furthermore, we propose a mechanism that translates this maximum into differential growth, and thus curvature, of the apical hook. Through a combination of experimental and in silico computational approaches, we have identified the individual contributions of differential cell elongation and proliferation to defining the apical hook and reveal the role of auxin-ethylene crosstalk in balancing these two processes. PMID:27754878

  18. Analysis of streamflow-gaging network for monitoring stormwater in small streams in the Puget Sound Basin, Washington

    USGS Publications Warehouse

    Konrad, Christopher P.; Voss, Frank D.

    2012-01-01

    The streamflow-gaging network in the Puget Sound basin was analyzed for its capacity to monitor stormwater in small streams. The analysis consisted of an inventory of active and inactive gages and an evaluation of the coverage and resolution of the gaging network with an emphasis on lowland areas. The active gaging network covers much of the Puget Lowland largely by gages located at sites on larger streams and rivers. Assessments of stormwater impacts and management will likely require streamflow information with higher spatial resolution than provided by the current gaging network. Monitoring that emphasizes small streams in combination with approaches for estimating streamflow at ungaged sites provides an alternative to expanding the current gaging network that can improve the spatial resolution of streamflow information in the region. The highest priority gaps in the gaging network are low elevation basins close to the Puget Sound shoreline and sites that share less than 10 percent of the drainage area of an active gage. Although small, lowland sites with long records of streamflow are particularly valuable to maintain in the region, other criteria for prioritizing sites in the gaging network should be based on the specific questions that stormwater managers need to answer.

  19. Evaluation of the streamflow-gaging network of Alaska in providing regional streamflow information

    USGS Publications Warehouse

    Brabets, Timothy P.

    1996-01-01

    In 1906, the U.S. Geological Survey (USGS) began operating a network of streamflow-gaging stations in Alaska. The primary purpose of the streamflow- gaging network has been to provide peak flow, average flow, and low-flow characteristics to a variety of users. In 1993, the USGS began a study to evaluate the current network of 78 stations. The objectives of this study were to determine the adequacy of the existing network in predicting selected regional flow characteristics and to determine if providing additional streamflow-gaging stations could improve the network's ability to predict these characteristics. Alaska was divided into six distinct hydrologic regions: Arctic, Northwest, Southcentral, Southeast, Southwest, and Yukon. For each region, historical and current streamflow data were compiled. In Arctic, Northwest, and Southwest Alaska, insufficient data were available to develop regional regression equations. In these areas, proposed locations of streamflow-gaging stations were selected by using clustering techniques to define similar areas within a region and by spatial visual analysis using the precipitation, physiographic, and hydrologic unit maps of Alaska. Sufficient data existed in Southcentral and Southeast Alaska to use generalized least squares (GLS) procedures to develop regional regression equations to estimate the 50-year peak flow, annual average flow, and a low-flow statistic. GLS procedures were also used for Yukon Alaska but the results should be used with caution because the data do not have an adequate spatial distribution. Network analysis procedures were used for the Southcentral, Southeast, and Yukon regions. Network analysis indicates the reduction in the sampling error of the regional regression equation that can be obtained given different scenarios. For Alaska, a 10-year planning period was used. One scenario showed the results of continuing the current network with no additional gaging stations and another scenario showed the results

  20. Effectiveness of the New Hampshire stream-gaging network in providing regional streamflow information

    USGS Publications Warehouse

    Olson, Scott A.

    2003-01-01

    The stream-gaging network in New Hampshire was analyzed for its effectiveness in providing regional information on peak-flood flow, mean-flow, and low-flow frequency. The data available for analysis were from stream-gaging stations in New Hampshire and selected stations in adjacent States. The principles of generalized-least-squares regression analysis were applied to develop regional regression equations that relate streamflow-frequency characteristics to watershed characteristics. Regression equations were developed for (1) the instantaneous peak flow with a 100-year recurrence interval, (2) the mean-annual flow, and (3) the 7-day, 10-year low flow. Active and discontinued stream-gaging stations with 10 or more years of flow data were used to develop the regression equations. Each stream-gaging station in the network was evaluated and ranked on the basis of how much the data from that station contributed to the cost-weighted sampling-error component of the regression equation. The potential effect of data from proposed and new stream-gaging stations on the sampling error also was evaluated. The stream-gaging network was evaluated for conditions in water year 2000 and for estimated conditions under various network strategies if an additional 5 years and 20 years of streamflow data were collected. The effectiveness of the stream-gaging network in providing regional streamflow information could be improved for all three flow characteristics with the collection of additional flow data, both temporally and spatially. With additional years of data collection, the greatest reduction in the average sampling error of the regional regression equations was found for the peak- and low-flow characteristics. In general, additional data collection at stream-gaging stations with unregulated flow, relatively short-term record (less than 20 years), and drainage areas smaller than 45 square miles contributed the largest cost-weighted reduction to the average sampling error of the

  1. The index gage method to develop a flow duration curve from short-term streamflow records

    NASA Astrophysics Data System (ADS)

    Zhang, Zhenxing

    2017-10-01

    The flow duration curve (FDC) is one of the most commonly used graphical tools in hydrology and provides a comprehensive graphical view of streamflow variability at a particular site. For a gaged site, an FDC can be easily estimated with frequency analysis. When no streamflow records are available, regional FDCs are used to synthesize FDCs. However, studies on how to develop FDCs for sites with short-term records have been very limited. Deriving representative FDC when there are short-term hydrologic records is important. For instance, 43% of the 394 streamflow gages in Illinois have records of 20 years or fewer, and these short-term gages are often distributed in headwaters and contain valuable hydrologic information. In this study, the index gage method is proposed to develop FDCs using short-term hydrologic records via an information transfer technique from a nearby hydrologically similar index gage. There are three steps: (1) select an index gage; (2) determine changes of FDC; and (3) develop representative FDCs. The approach is tested using records from 92 U.S. Geological Survey streamflow gages in Illinois. A jackknife experiment is conducted to assess the performance. Bootstrap resampling is used to simulate various periods of records, i.e., 1, 2, 5, 10, 15, and 20 years of records. The results demonstrated that the index gage method is capable of developing a representative FDC using short-term records. Generally, the approach performance is improved when more hydrologic records are available, but the improvement appears to level off when the short-term gage has 10 years or more records.

  2. Relationship between tornadoes and hook echoes on April 3, 1974

    NASA Technical Reports Server (NTRS)

    Forbes, G. S.

    1975-01-01

    Radar observations of tornado families occurring on April 3, 1974 are discussed. Of the 93 tornadoes included in the sample, 81% were associated with hook-like echoes with appendages at least 40 deg to the south of the echo movement. At least one tornado was associated with 62% of the hook-like echoes observed. All of the tornadoes with intensities of F 4 and F 5 were produced by hook-like echoes; the mean intensity of all tornadoes associated with this type of echo was F 3, while the mean intensity of the remaining tornadoes was F1. The tornadic hook-like echoes moved to the right of the non-tornadic echoes forming a tornado line in advance of the squall line. Some tornadoes were associated with 'spiral' echoes.

  3. Matilda Joslyn Gage: A Nineteenth-Century Women's Rights Historian Looks at Witchcraft.

    ERIC Educational Resources Information Center

    Corey, Mary E.

    2003-01-01

    Explores the ideas of the nineteenth century female historian, Matilda Joslyn Gage, who authored the book, "Woman, Church, and State." Focuses on Gage's ideas about women's history, particularly related to the role of the church and women persecuted for witchcraft. (CMK)

  4. Cost effectiveness of the US Geological Survey's stream-gaging programs in New Hampshire and Vermont

    USGS Publications Warehouse

    Smath, J.A.; Blackey, F.E.

    1986-01-01

    Data uses and funding sources were identified for the 73 continuous stream gages currently (1984) being operated. Eight stream gages were identified as having insufficient reason to continue their operation. Parts of New Hampshire and Vermont were identified as needing additional hydrologic data. New gages should be established in these regions as funds become available. Alternative methods for providing hydrologic data at the stream gaging stations currently being operated were found to lack the accuracy that is required for their intended use. The current policy for operation of the stream gages requires a net budget of $297,000/yr. The average standard error of estimation of the streamflow records is 17.9%. This overall level of accuracy could be maintained with a budget of $285,000 if resources were redistributed among gages. Cost-effective analysis indicates that with the present budget, the average standard error could be reduced to 16.6%. A minimum budget of $278,000 is required to operate the present stream gaging program. Below this level, the gages and recorders would not receive the proper service and maintenance. At the minimum budget, the average standard error would be 20.4%. The loss of correlative data is a significant component of the error in streamflow records, especially at lower budgetary levels. (Author 's abstract)

  5. Stainless hooks to bond lower lingual retainer.

    PubMed

    Durgekar, Sujala G; Nagaraj, K

    2011-01-01

    We introduced a simple and economical technique for precise placement of lower lingual retainers. Two stainless steel hooks made of 0.6mm wire are placed interdentally in the embrasure area between canine and lateral incisor bilaterally to lock the retainer wire in the correct position. Etch, rinse and dry the enamel surfaces with the retainer passively in place, then bond the retainer with light-cured adhesive. Hooks are simple to fabricate and eliminate the need for a transfer tray.

  6. In-Flight Capability for Evaluating Skin-Friction Gages and Other Near-Wall Flow Sensors

    NASA Technical Reports Server (NTRS)

    Bui, Trong T.; Pipitone, Brett J.; Krake, Keith L.; Richwine, Dave (Technical Monitor)

    2003-01-01

    An 8-in.-square boundary-layer sensor panel has been developed for in-flight evaluation of skin-friction gages and other near-wall flow sensors on the NASA Dryden Flight Research Center F-15B/Flight Test Fixture (FTF). Instrumentation on the sensor panel includes a boundary-layer rake, temperature sensors, static pressure taps, and a Preston tube. Space is also available for skin-friction gages or other near-wall flow sensors. Pretest analysis of previous F-15B/FTF flight data has identified flight conditions suitable for evaluating skin-friction gages. At subsonic Mach numbers, the boundary layer over the sensor panel closely approximates the two-dimensional (2D), law-of-the-wall turbulent boundary layer, and skin-friction estimates from the Preston tube and the rake (using the Clauser plot method) can be used to evaluate skin-friction gages. At supersonic Mach numbers, the boundary layer over the sensor panel becomes complex, and other means of measuring skin friction are needed to evaluate the accuracy of new skin-friction gages. Results from the flight test of a new rubber-damped skin-friction gage confirm that at subsonic Mach numbers, nearly 2D, law-of-the-wall turbulent boundary layers exist over the sensor panel. Sensor panel data also show that this new skin-friction gage prototype does not work in flight.

  7. Expanding-Circle Students Learning "Standard English" in the Outer-Circle Asia

    ERIC Educational Resources Information Center

    Kobayashi, Yoko

    2011-01-01

    Drawing upon Kachru's concentric circles of English, the present study explores whether middle-class Japanese students who chose to study English solo at private language schools in Singapore diverge from many others who (wish to) study inner-circle English. The study is stimulated by the repeated interdisciplinary findings that, in spite of the…

  8. Cooperative binding mitigates the high-dose hook effect.

    PubMed

    Roy, Ranjita Dutta; Rosenmund, Christian; Stefan, Melanie I

    2017-08-14

    The high-dose hook effect (also called prozone effect) refers to the observation that if a multivalent protein acts as a linker between two parts of a protein complex, then increasing the amount of linker protein in the mixture does not always increase the amount of fully formed complex. On the contrary, at a high enough concentration range the amount of fully formed complex actually decreases. It has been observed that allosterically regulated proteins seem less susceptible to this effect. The aim of this study was two-fold: First, to investigate the mathematical basis of how allostery mitigates the prozone effect. And second, to explore the consequences of allostery and the high-dose hook effect using the example of calmodulin, a calcium-sensing protein that regulates the switch between long-term potentiation and long-term depression in neurons. We use a combinatorial model of a "perfect linker protein" (with infinite binding affinity) to mathematically describe the hook effect and its behaviour under allosteric conditions. We show that allosteric regulation does indeed mitigate the high-dose hook effect. We then turn to calmodulin as a real-life example of an allosteric protein. Using kinetic simulations, we show that calmodulin is indeed subject to a hook effect. We also show that this effect is stronger in the presence of the allosteric activator Ca 2+ /calmodulin-dependent kinase II (CaMKII), because it reduces the overall cooperativity of the calcium-calmodulin system. It follows that, surprisingly, there are conditions where increased amounts of allosteric activator actually decrease the activity of a protein. We show that cooperative binding can indeed act as a protective mechanism against the hook effect. This will have implications in vivo where the extent of cooperativity of a protein can be modulated, for instance, by allosteric activators or inhibitors. This can result in counterintuitive effects of decreased activity with increased concentrations of

  9. Analysis of strain gage reliability in F-100 jet engine testing at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Holanda, R.

    1983-01-01

    A reliability analysis was performed on 64 strain gage systems mounted on the 3 rotor stages of the fan of a YF-100 engine. The strain gages were used in a 65 hour fan flutter research program which included about 5 hours of blade flutter. The analysis was part of a reliability improvement program. Eighty-four percent of the strain gages survived the test and performed satisfactorily. A post test analysis determined most failure causes. Five failures were caused by open circuits, three failed gages showed elevated circuit resistance, and one gage circuit was grounded. One failure was undetermined.

  10. Role of PIN-mediated auxin efflux in apical hook development of Arabidopsis thaliana.

    PubMed

    Zádníková, Petra; Petrásek, Jan; Marhavy, Peter; Raz, Vered; Vandenbussche, Filip; Ding, Zhaojun; Schwarzerová, Katerina; Morita, Miyo T; Tasaka, Masao; Hejátko, Jan; Van Der Straeten, Dominique; Friml, Jirí; Benková, Eva

    2010-02-01

    The apical hook of dark-grown Arabidopsis seedlings is a simple structure that develops soon after germination to protect the meristem tissues during emergence through the soil and that opens upon exposure to light. Differential growth at the apical hook proceeds in three sequential steps that are regulated by multiple hormones, principally auxin and ethylene. We show that the progress of the apical hook through these developmental phases depends on the dynamic, asymmetric distribution of auxin, which is regulated by auxin efflux carriers of the PIN family. Several PIN proteins exhibited specific, partially overlapping spatial and temporal expression patterns, and their subcellular localization suggested auxin fluxes during hook development. Genetic manipulation of individual PIN activities interfered with different stages of hook development, implying that specific combinations of PIN genes are required for progress of the apical hook through the developmental phases. Furthermore, ethylene might modulate apical hook development by prolonging the formation phase and strongly suppressing the maintenance phase. This ethylene effect is in part mediated by regulation of PIN-dependent auxin efflux and auxin signaling.

  11. Cost-effectiveness of the stream-gaging program in New Jersey

    USGS Publications Warehouse

    Schopp, R.D.; Ulery, R.L.

    1984-01-01

    The results of a study of the cost-effectiveness of the stream-gaging program in New Jersey are documented. This study is part of a 5-year nationwide analysis undertaken by the U.S. Geological Survey to define and document the most cost-effective means of furnishing streamflow information. This report identifies the principal uses of the data and relates those uses to funding sources, applies, at selected stations, alternative less costly methods (that is flow routing, regression analysis) for furnishing the data, and defines a strategy for operating the program which minimizes uncertainty in the streamflow data for specific operating budgets. Uncertainty in streamflow data is primarily a function of the percentage of missing record and the frequency of discharge measurements. In this report, 101 continuous stream gages and 73 crest-stage or stage-only gages are analyzed. A minimum budget of $548,000 is required to operate the present stream-gaging program in New Jersey with an average standard error of 27.6 percent. The maximum budget analyzed was $650,000, which resulted in an average standard error of 17.8 percent. The 1983 budget of $569,000 resulted in a standard error of 24.9 percent under present operating policy. (USGS)

  12. Cost-effectiveness of the stream-gaging program in North Carolina

    USGS Publications Warehouse

    Mason, R.R.; Jackson, N.M.

    1985-01-01

    This report documents the results of a study of the cost-effectiveness of the stream-gaging program in North Carolina. Data uses and funding sources are identified for the 146 gaging stations currently operated in North Carolina with a budget of $777,600 (1984). As a result of the study, eleven stations are nominated for discontinuance and five for conversion from recording to partial-record status. Large parts of North Carolina 's Coastal Plain are identified as having sparse streamflow data. This sparsity should be remedied as funds become available. Efforts should also be directed toward defining the efforts of drainage improvements on local hydrology and streamflow characteristics. The average standard error of streamflow records in North Carolina is 18.6 percent. This level of accuracy could be improved without increasing cost by increasing the frequency of field visits and streamflow measurements at stations with high standard errors and reducing the frequency at stations with low standard errors. A minimum budget of $762,000 is required to operate the 146-gage program. A budget less than this does not permit proper service and maintenance of the gages and recorders. At the minimum budget, and with the optimum allocation of field visits, the average standard error is 17.6 percent.

  13. Strain Gage Measurements of Aft Nacelle Shock Absorbers.

    DTIC Science & Technology

    ENGINE NACELLES, SHOCK ABSORBERS ), (* SHOCK ABSORBERS , STRESSES), SURFACE TO SURFACE MISSILES, LAUNCHING, STRAIN GAGES, COMPRESSIVE PROPERTIES, CALIBRATION, STRAIN(MECHANICS), FAILURE, GROUND SUPPORT EQUIPMENT.

  14. A Round Is a Circle...

    ERIC Educational Resources Information Center

    Boyarsky, Terry L.

    2006-01-01

    Circles are everywhere and endlessly intriguing. We know, sense, and feel them in time, space, sound, and the cycles of nature. A person's life contains spirals, repetitions, going out and coming back. Poets write of circles; composers write song cycles. Circles are at the root of the curriculum, concepts deep yet accessible, infinite in their…

  15. Detection of Bi-Directionality in Strain-Gage Balance Calibration Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, Norbert

    2012-01-01

    An indicator variable was developed for both visualization and detection of bi-directionality in wind tunnel strain-gage balance calibration data. First, the calculation of the indicator variable is explained in detail. Then, a criterion is discussed that may be used to decide which gage outputs of a balance have bi- directional behavior. The result of this analysis could be used, for example, to justify the selection of certain absolute value or other even function terms in the regression model of gage outputs whenever the Iterative Method is chosen for the balance calibration data analysis. Calibration data of NASA s MK40 Task balance is analyzed to illustrate both the calculation of the indicator variable and the application of the proposed criterion. Finally, bi directionality characteristics of typical multi piece, hybrid, single piece, and semispan balances are determined and discussed.

  16. Rainfall, streamflow, and peak stage data collected at the Murfreesboro, Tennessee, gaging network, March 1989 through July 1992

    USGS Publications Warehouse

    Outlaw, G.S.; Butner, D.E.; Kemp, R.L.; Oaks, A.T.; Adams, G.S.

    1992-01-01

    Rainfall, stage, and streamflow data in the Murfreesboro area, Middle Tennessee, were collected from March 1989 through July 1992 from a network of 68 gaging stations. The network consists of 10 tipping-bucket rain gages, 2 continuous-record streamflow gages, 4 partial-record flood hydrograph gages, and 72 crest-stage gages. Data collected by the gages includes 5minute time-step rainfall hyetographs, 15-minute time-step flood hydrographs, and peak-stage elevations. Data are stored in a computer data base and are available for many computer modeling and engineering applications.

  17. Sandy Hook : alternative access concept plan and vehicle replacement study

    DOT National Transportation Integrated Search

    2009-06-01

    This study addresses two critical issues of concern to the Sandy Hook Unit of Gateway National : Recreational Area: (1) options for alternative access to Sandy Hook during peak summer season, : particularly when the park is closed to private vehicles...

  18. An Elastic Tube Gage for Measuring Static and Dynamic Pressures

    DTIC Science & Technology

    1948-05-01

    AUXILIARY HEAT RADIATORS - .-. • • /•’ • • • AUXILIARY ELECTRICAL AND RECORDING EQUIPMENT . . . . .. RESULTS OF FIELD TESTS...time and resources and to permit a greater flexibility in use where measurements are required of a large number or variety of quantities.. Since...gages are first prercürved to fit the tube., and then cemented with Duco. After air-drying for H8 hours, the gages, are heated with infrared lamps to

  19. The effects of flagellar hook compliance on motility of monotrichous bacteria: A modeling study

    NASA Astrophysics Data System (ADS)

    Shum, H.; Gaffney, E. A.

    2012-06-01

    A crucial structure in the motility of flagellated bacteria is the hook, which connects the flagellum filament to the motor in the cell body. Early mathematical models of swimming bacteria assume that the helically shaped flagellum rotates rigidly about its axis, which coincides with the axis of the cell body. Motivated by evidence that the hook is much more flexible than the rest of the flagellum, we develop a new model that allows a naturally straight hook to bend. Hook dynamics are based on the Kirchhoff rod model, which is combined with a boundary element method for solving viscous interactions between the bacterium and the surrounding fluid. For swimming in unbounded fluid, we find good support for using a rigid model since the hook reaches an equilibrium configuration within several revolutions of the motor. However, for effective swimming, there are constraints on the hook stiffness relative to the scale set by the product of the motor torque with the hook length. When the hook is too flexible, its shape cannot be maintained and large deformations and stresses build up. When the hook is too rigid, the flagellum does not align with the cell body axis and the cell "wobbles" with little net forward motion. We also examine the attraction of swimmers to no-slip surfaces and find that the tendency to swim steadily close to a surface can be very sensitive to the combination of the hook rigidity and the precise shape of the cell and flagellum.

  20. Calibration and evaluation tests of strain gages for use on structure exposed to cryogenic and reentry temperatures

    NASA Astrophysics Data System (ADS)

    Mueller, Richard N.; Howard, J. Lawrence; Sikorra, Charles F.; Swegle, Allan R.

    Commercial strain gages were evaluated for proposed strain measurement on a Rene 41 honeycomb test panel to be subjected to temperatures from -423 F to +1600 F. Foil strain gages of three different temperature compensations, a weldable strain gage, and a capacitive strain gage, were tested to determine characteristics of apparent strain, strain sensitivity, and temperature operational limits under stabilized temperature and several heating and cooling temperature rates. Test results show that strain measurement over the total temperature range can be made using a combination of gages.

  1. Development and impact of hooks of high droplet concentration on remote southeast Pacific stratocumulus

    NASA Astrophysics Data System (ADS)

    George, R. C.; Wood, R.; Bretherton, C. S.; Painter, G.

    2013-07-01

    Over the southeastern Pacific (SEP), droplet concentration (Nd) in the typically unpolluted marine stratocumulus west of 80° W (> 1000 km offshore) is periodically strongly enhanced in zonally elongated "hook"-shaped features that increase albedo. Here, we examine three hook events using the chemistry version of the Weather Research and Forecasting model (WRF-Chem) with 14 km horizontal resolution, satellite data, and aircraft data from the VAMOS Ocean-Cloud-Atmosphere-Land Study Regional Experiment (VOCALS-REx). A particularly strong hook yields insights into the development, decay, and radiative impact of these features. Hook development occurs with Nd increasing to polluted levels over the remote ocean primarily due to entrainment of cloud condensation nuclei (CCN) from the lower free troposphere (FT). The feature advects northwestward until the FT CCN source is depleted, after which Nd decreases over a few days due to precipitation and dilution. The model suggests that the FT CCN source supplying the hook consists of high concentrations of small accumulation-mode aerosols that contribute a relatively small amount of aerosol mass to the MBL, in agreement with near-coast VOCALS measurements of polluted layers in the FT. The aerosol particles in this hook originate mainly from a pulse of offshore flow that transports Santiago-region (33-35° S) emissions to the remote marine FT. To provide pollution CCN that can sustain hooks, the FT transport of pollution plumes to the remote ocean requires strong, deep offshore flow. Such flow is favored by a trough approaching the South American coast and a southeastward shift of the climatological subtropical high-pressure system. The model simulations show precipitation suppression in the hook and a corresponding increase in liquid water path (LWP) compared with a simulation without anthropogenic sources. LWP also increases as the hook evolves over time due to increasing stability and decreasing subsidence. WRF-Chem suggests

  2. Dimensional threshold for fracture linkage and hooking

    NASA Astrophysics Data System (ADS)

    Lamarche, Juliette; Chabani, Arezki; Gauthier, Bertrand D. M.

    2018-03-01

    Fracture connectivity in rocks depends on spatial properties of the pattern including length, abundance and orientation. When fractures form a single-strike set, they hardly cross-cut each other and the connectivity is limited. Linkage probability increases with increasing fracture abundance and length as small fractures connect to each other to form longer ones. A process for parallel fracture linkage is the "hooking", where two converging fracture tips mutually deviate and then converge to connect due to the interaction of their crack-tip stresses. Quantifying the processes and conditions for fracture linkage in single-strike fracture sets is crucial to better predicting fluid flow in Naturally Fractured Reservoirs. For 1734 fractures in Permian shales of the Lodève Basin, SE France, we measured geometrical parameters in 2D, characterizing three stages of the hooking process: underlapping, overlapping and linkage. We deciphered the threshold values, shape ratios and limiting conditions to switch from one stage to another one. The hook set up depends on the spacing (S) and fracture length (Lh) with the relation S ≈ 0.15 Lh. Once the hooking is initiated, with the fracture deviation length (L) L ≈ 0.4 Lh, the fractures reaches the linkage stage only when the spacing is reduced to S ≈ 0.02 Lh and the convergence (C) is < 0.1 L. These conditions apply to multi-scale fractures with a shape ratio L/S = 10 and for fracture curvature of 10°-20°.

  3. Walking straight into circles.

    PubMed

    Souman, Jan L; Frissen, Ilja; Sreenivasa, Manish N; Ernst, Marc O

    2009-09-29

    Common belief has it that people who get lost in unfamiliar terrain often end up walking in circles. Although uncorroborated by empirical data, this belief has widely permeated popular culture. Here, we tested the ability of humans to walk on a straight course through unfamiliar terrain in two different environments: a large forest area and the Sahara desert. Walking trajectories of several hours were captured via global positioning system, showing that participants repeatedly walked in circles when they could not see the sun. Conversely, when the sun was visible, participants sometimes veered from a straight course but did not walk in circles. We tested various explanations for this walking behavior by assessing the ability of people to maintain a fixed course while blindfolded. Under these conditions, participants walked in often surprisingly small circles (diameter < 20 m), though rarely in a systematic direction. These results rule out a general explanation in terms of biomechanical asymmetries or other general biases [1-6]. Instead, they suggest that veering from a straight course is the result of accumulating noise in the sensorimotor system, which, without an external directional reference to recalibrate the subjective straight ahead, may cause people to walk in circles.

  4. Hooking injury, physiological status and short-term mortality of juvenile lemon sharks (Negaprion bevirostris) following catch-and-release recreational angling

    PubMed Central

    Danylchuk, Andy J.; Suski, Cory D.; Mandelman, John W.; Murchie, Karen J.; Haak, Christopher R.; Brooks, Annabelle M. L.; Cooke, Steven J.

    2014-01-01

    Sport fishing for sharks, including fishing with the intent to release, is becoming more prevalent within the recreational angling community. Common targets of recreational anglers are juvenile lemon sharks (Negaprion brevirostris) that frequent shallow tropical nearshore habitats. In this study, we captured 32 juvenile lemon sharks (530–875 mm total length) with conventional angling gear (i.e. spinning rods, dead fish bait and 5/0 barbed circle hooks) from the coastal waters of Eleuthera, The Bahamas, to determine the consequences of capture for individual sharks. Each shark was examined for hooking injuries, blood sampled to quantify physiological disturbance, assessed for reflex impairment and then monitored to assess post-release behaviour and mortality. Four sharks (12.5%) died following release during the 15 min tracking period. Principal components (PC) analysis revealed four axes describing 66.5% of the variance for blood physiology parameters, total length and water temperature. The PC1 and PC3 scores, characterized by positive factor loadings for indicators of exercise-induced stress and blood ion concentrations, respectively, were significantly related to fight time but were not associated with short-term mortality. Short-term mortality was significantly related to factor scores for PC4 that loaded heavily for water temperature and total length. Ten sharks (31%) exhibited impaired reflexes, with loss of bite reflex being most prevalent. Sharks that died had the following characteristics: (i) they had two or more impaired reflexes; (ii) they were hooked in the basihyal; (iii) they exhibited no movement after the initial bout of directional swimming; and (iv) they experienced high water temperatures (i.e. >31°C). Collectively, these results indicate that for juvenile lemon sharks inhabiting tropical flats, fight time can influence the degree of physiological disturbance, while water temperature contributes to the likelihood of survival

  5. Hooking injury, physiological status and short-term mortality of juvenile lemon sharks (Negaprion bevirostris) following catch-and-release recreational angling.

    PubMed

    Danylchuk, Andy J; Suski, Cory D; Mandelman, John W; Murchie, Karen J; Haak, Christopher R; Brooks, Annabelle M L; Cooke, Steven J

    2014-01-01

    Sport fishing for sharks, including fishing with the intent to release, is becoming more prevalent within the recreational angling community. Common targets of recreational anglers are juvenile lemon sharks (Negaprion brevirostris) that frequent shallow tropical nearshore habitats. In this study, we captured 32 juvenile lemon sharks (530-875 mm total length) with conventional angling gear (i.e. spinning rods, dead fish bait and 5/0 barbed circle hooks) from the coastal waters of Eleuthera, The Bahamas, to determine the consequences of capture for individual sharks. Each shark was examined for hooking injuries, blood sampled to quantify physiological disturbance, assessed for reflex impairment and then monitored to assess post-release behaviour and mortality. Four sharks (12.5%) died following release during the 15 min tracking period. Principal components (PC) analysis revealed four axes describing 66.5% of the variance for blood physiology parameters, total length and water temperature. The PC1 and PC3 scores, characterized by positive factor loadings for indicators of exercise-induced stress and blood ion concentrations, respectively, were significantly related to fight time but were not associated with short-term mortality. Short-term mortality was significantly related to factor scores for PC4 that loaded heavily for water temperature and total length. Ten sharks (31%) exhibited impaired reflexes, with loss of bite reflex being most prevalent. Sharks that died had the following characteristics: (i) they had two or more impaired reflexes; (ii) they were hooked in the basihyal; (iii) they exhibited no movement after the initial bout of directional swimming; and (iv) they experienced high water temperatures (i.e. >31°C). Collectively, these results indicate that for juvenile lemon sharks inhabiting tropical flats, fight time can influence the degree of physiological disturbance, while water temperature contributes to the likelihood of survival

  6. Latin-square three-dimensional gage master

    DOEpatents

    Jones, L.

    1981-05-12

    A gage master for coordinate measuring machines has an nxn array of objects distributed in the Z coordinate utilizing the concept of a Latin square experimental design. Using analysis of variance techniques, the invention may be used to identify sources of error in machine geometry and quantify machine accuracy.

  7. Latin square three dimensional gage master

    DOEpatents

    Jones, Lynn L.

    1982-01-01

    A gage master for coordinate measuring machines has an nxn array of objects distributed in the Z coordinate utilizing the concept of a Latin square experimental design. Using analysis of variance techniques, the invention may be used to identify sources of error in machine geometry and quantify machine accuracy.

  8. Reflections on Sandy Hook

    ERIC Educational Resources Information Center

    Trump, Kenneth S.

    2013-01-01

    In this article, the author shares his thoughts for district administrators regarding the Sandy Hook Elementary school tragedy. Administrators heard a lot of potential solutions or attempts at solutions. However, these proposals raise lengthy lists of implementation questions and issues that illustrate a lack of understanding of school operations,…

  9. High temperature static strain gage development

    NASA Technical Reports Server (NTRS)

    Hulse, C. O.; Bailey, R. S.; Grant, H. P.; Anderson, W. L.; Przybyszewski, J. S.

    1991-01-01

    Final results are presented from a program to develop a thin film static strain gage for use on the blades and vanes of running, test stand gas turbine engines with goals of an 3 x 3 mm gage area and total errors of less than 10 pct. of + or - 2,000 microstrain after 50 hrs at 1250 K. Pd containing 13 Wt. pct. Cr was previously identified as a new strain sensor alloy that appeared to be potentially usable to 1250 K. Subsequently, it was discovered, in contrast with its behavior in bulk, that Pd-13Cr suffered from oxidation attack when prepared as a 4.5 micron thick thin film. Continuing problems with electrical leakage to the substrate and the inability of sputtered alumina overcoats to prevent oxidation led to the discovery that sputtered alumina contains appreciable amounts of entrapped argon. After the argon has been exsolved by heating to elevated temperatures, the alumina films undergo a linear shrinkage of about 2 pct. resulting in formation of cracks. These problems can be largely overcome by sputtering the alumina with the substrate heated to 870 K. With 2 micron thick hot sputtered alumina insulation and overcoat films, total 50 hr drifts of about 100 microstrain (2 tests) and about 500 microstrain (1 test) were observed at 1000 and 1100 K, respectively. Results of tests on complete strain gage systems on constant moment bend bars with Pd temperature compensation grids revealed that oxidation of the Pd grid was a major problem even when the grid was overcoated with a hot or cold sputtered alumina overcoat.

  10. Evaluation of Troxler model 3411 nuclear gage.

    DOT National Transportation Integrated Search

    1978-01-01

    The performance of the Troxler Electronics Laboratory Model 3411 nuclear gage was evaluated through laboratory tests on the Department's density and moisture standards and field tests on various soils, base courses, and bituminous concrete overlays t...

  11. Bohlin transformation: the hidden symmetry that connects Hooke to Newton

    NASA Astrophysics Data System (ADS)

    Saggio, Maria Luisa

    2013-01-01

    Hooke's name is familiar to students of mechanics thanks to the law of force that bears his name. Less well-known is the influence his findings had on the founder of mechanics, Isaac Newton. In a lecture given some twenty years ago, W Arnol'd pointed out the outstanding contribution to science made by Hooke, and also noted the controversial issue of the attribution of important discoveries to Newton that were actually inspired by Hooke. It therefore seems ironic that the two most famous force laws, named after Hooke and Newton, are two geometrical aspects of the same law. This relationship, together with other illuminating aspects of Newtonian mechanics, is described in Arnol'd's book and is worth remembering in standard physics courses. In this didactical paper the duality of the two forces is expounded and an account of the more recent contributions to the subject is given.

  12. Absorption of metals in mulloway (Argyrosomus japonicus) after ingesting nickel-plated carbon-steel hooks.

    PubMed

    McGrath, Shane P; Reichelt-Brushett, Amanda J; Butcher, Paul A; Cairns, Stuart C

    2014-08-01

    Previous research has alluded to the potential of metals being absorbed by fish after ingesting fishing hooks, which may have adverse effects on fish health and the organisms that consume them. Subsequently, this study aimed to quantify the potential of mulloway (Argyrosomus japonicus) to absorb metals during the decay of ingested nickel-plated carbon-steel hooks. Twenty-five treatment fish were allowed to ingest nickel-plated carbon-steel hooks during angling and then monitored with 25 controls (untreated fish) for up to 42 days for hook ejection and mortality. Blood, liver and muscle samples were collected from treatment, control and 14 wild-caught individuals to determine the concentrations of chromium, cobalt, copper, iron, manganese and nickel. The results showed that increased oxidation influenced hook ejection, and that hook-ingested fish had significantly elevated concentrations of nickel in their liver and blood, but not muscle. This research has shown that there is an avenue for metal absorption from ingested hooks. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Cost-effectiveness of the Federal stream-gaging program in Virginia

    USGS Publications Warehouse

    Carpenter, D.H.

    1985-01-01

    Data uses and funding sources were identified for the 77 continuous stream gages currently being operated in Virginia by the U.S. Geological Survey with a budget of $446,000. Two stream gages were identified as not being used sufficiently to warrant continuing their operation. Operation of these stations should be considered for discontinuation. Data collected at two other stations were identified as having uses primarily related to short-term studies; these stations should also be considered for discontinuation at the end of the data collection phases of the studies. The remaining 73 stations should be kept in the program for the foreseeable future. The current policy for operation of the 77-station program requires a budget of $446,000/yr. The average standard error of estimation of streamflow records is 10.1%. It was shown that this overall level of accuracy at the 77 sites could be maintained with a budget of $430,500 if resources were redistributed among the gages. A minimum budget of $428,500 is required to operate the 77-gage program; a smaller budget would not permit proper service and maintenance of the gages and recorders. At the minimum budget, with optimized operation, the average standard error would be 10.4%. The maximum budget analyzed was $650,000, which resulted in an average standard error of 5.5%. The study indicates that a major component of error is caused by lost or missing data. If perfect equipment were available, the standard error for the current program and budget could be reduced to 7.6%. This also can be interpreted to mean that the streamflow data have a standard error of this magnitude during times when the equipment is operating properly. (Author 's abstract)

  14. Sandy Hook Traveler Information System

    DOT National Transportation Integrated Search

    2010-09-01

    This report focuses on equipment and procedural solutions for gathering and disseminating a wide range of visitor information, including real-time traveler information data relating to traffic and parking at the Sandy Hook Unit of the Gateway Recreat...

  15. The hook effect in calcitonin immunoradiometric assay: a case report.

    PubMed

    Fangous, Marie-Sarah; Kerspern, Hélène; Moineau, Marie-Pierre; Kerlan, Véronique; Alavi, Zarrin; Carré, Jean-Luc

    2012-12-01

    The hook effect, which has long been detected and documented for immunoradiometric assays (IRMA) such as those measuring prolactin or thyroglobulin, occurs when the serum antigen level is extremely high, thus inducing a bias in the methodology of measurement. We report the case of an 80-year-old man with confirmed medullary thyroid carcinoma (MTC). In the case reported here, the clinical status of the patient contrasts with his tumor antigen, serum calcitonin (CT), concentrations. The measured increased CT concentrations revealed the presence of a hook effect. This phenomenon occurs due to an excess of antigen during the one-step IRMA where the signal antibodies, bound to the non-captured antigens, are washed out during the measurement, inducing the loss of signal. Aiming to prevent the "hook effect", successive dilutions of the same sample of serum were done. Previous studies have shown when one-step IRMA reveals high concentrations of a tumor serum antigen (i.e. prolactin or thyroglobulin), a two-step IRMA or a systematic 1:10 dilution of the serum sample prevents the formation of the "hook effect". In our case report, the CT "hook effect" formation was prevented by performing serial dilutions of the serum sample. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  16. Experiments Testing the Causes of Namibian Fairy Circles.

    PubMed

    Tschinkel, Walter R

    2015-01-01

    The grasslands on the sandy soils of the eastern edge of the Namib Desert of Namibia are strikingly punctuated by millions of mostly regularly-spaced circular bare spots 2 to 10 m or more in diameter, generally with a margin of taller grasses. The causes of these so called fairy circles are unknown, but several hypotheses have been advanced. In October 2009, we set up experiments that specifically tested four hypothesized causes, and monitored these 5 times between 2009 and 2015. Grass exclusion in circles due to seepage of subterranean vapors or gases was tested by burying an impermeable barrier beneath fairy circles, but seedling density and growth did not differ from barrier-less controls. Plant germination and growth inhibition by allelochemicals or nutrient deficiencies in fairy circle soils were tested by transferring fairy circle soil to artificially cleared circles in the grassy matrix, and matrix soil to fairy circles (along with circle to circle and matrix to matrix controls). None of the transfers changed the seedling density and growth from the control reference conditions. Limitation of plant growth due to micronutrient depletion within fairy circles was tested by supplementing circles with a micronutrient mixture, but did not result in differences in plant seedling density and growth. Short-range vegetation competitive feedbacks were tested by creating artificially-cleared circles of 2 or 4 m diameter located 2 or 6 m from a natural fairy circle. The natural circles remained bare and the artificial circles revegetated. These four experiments provided evidence that fairy circles were not caused by subterranean vapors, that fairy circle soil per se did not inhibit plant growth, and that the circles were not caused by micronutrient deficiency. There was also no evidence that vegetative feedbacks affected fairy circles on a 2 to 10 m scale. Landscape-scale vegetative self-organization is discussed as a more likely cause of fairy circles.

  17. Development and impact of hooks of large droplet concentration on remote southeast Pacific stratocumulus

    NASA Astrophysics Data System (ADS)

    George, R. C.; Wood, R.; Bretherton, C. S.; Painter, G.

    2013-01-01

    Over the southeastern Pacific (SEP), droplet concentration (Nd) in the typically unpolluted marine stratocumulus west of 80° W (> 1000 km offshore) is periodically strongly enhanced in zonally-elongated "hook"-shaped arcs that increase albedo. Here, we examine three hook events using the chemistry version of the Weather Research and Forecasting model (WRF-Chem) with 14 km horizontal resolution, satellite data and aircraft data from the VAMOS Ocean-Cloud-Atmosphere-Land Study Regional Experiment (VOCALS-REx). A particularly strong hook yields insights to the development, decay, and radiative impact of these features. Hook development occurs with Nd increasing to polluted levels over the remote ocean primarily due to entrainment of cloud condensation nuclei (CCN) from the free troposphere (FT). The feature advects northwestward until the FT CCN source is depleted, after which Nd decreases over a few days due to precipitation and dilution. The model suggests that the FT CCN source supplying the hook consists of high concentrations of small accumulation mode aerosols that contribute a relatively small amount of aerosol mass to the MBL. The aerosol particles originate mainly from a pulse of offshore flow that transports Santiago region (33-35° S) emissions to the marine FT. To provide a sustained hook CCN source, the FT transport of pollution plumes to the remote ocean requires strong, deep offshore flow. Such flow is favored by a trough approaching the South American coast and a southeastward shift of the climatological subtropical high pressure system. The model simulations show precipitation suppression in the hook and a corresponding increase in liquid water path (LWP) compared with a simulation without anthropogenic sources. LWP also increases in time as the hook evolves due to increasing stability and decreasing subsidence. WRF-Chem suggests that DMS significantly influences the aerosol number and size distributions in a hook, but that hooks do not form without

  18. Cost effective stream-gaging strategies for the Lower Colorado River basin; the Blythe field office operations

    USGS Publications Warehouse

    Moss, Marshall E.; Gilroy, Edward J.

    1980-01-01

    This report describes the theoretical developments and illustrates the applications of techniques that recently have been assembled to analyze the cost-effectiveness of federally funded stream-gaging activities in support of the Colorado River compact and subsequent adjudications. The cost effectiveness of 19 stream gages in terms of minimizing the sum of the variances of the errors of estimation of annual mean discharge is explored by means of a sequential-search optimization scheme. The search is conducted over a set of decision variables that describes the number of times that each gaging route is traveled in a year. A gage route is defined as the most expeditious circuit that is made from a field office to visit one or more stream gages and return to the office. The error variance is defined as a function of the frequency of visits to a gage by using optimal estimation theory. Currently a minimum of 12 visits per year is made to any gage. By changing to a six-visit minimum, the same total error variance can be attained for the 19 stations with a budget of 10% less than the current one. Other strategies are also explored. (USGS)

  19. HOLEGAGE 1.0 - STRAIN GAGE HOLE DRILLING ANALYSIS PROGRAM

    NASA Technical Reports Server (NTRS)

    Hampton, R. W.

    1994-01-01

    There is no simple and perfect way to measure residual stresses in metal parts that have been welded or deformed to make complex structures such as pressure vessels and aircraft, yet these locked-in stresses can contribute to structural failure by fatigue and fracture. However, one proven and tested technique for determining the internal stress of a metal part is to drill a test hole while measuring the relieved strains around the hole, such as the hole-drilling strain gage method described in ASTM E 837. The program HOLEGAGE processes strain gage data and provides additional calculations of internal stress variations that are not obtained with standard E 837 analysis methods. The typical application of the technique uses a three gage rosette with a special hole-drilling fixture for drilling a hole through the center of the rosette to produce a hole with very small gage pattern eccentricity error. Another device is used to control the drilling and halt the drill at controlled depth steps. At each step, strains from all three strain gages are recorded. The influence coefficients used by HOLEGAGE to compute stresses from relieved hole strains were developed by published finite element method studies of thick plates for specific hole sizes and depths. The program uses a parabolic fit and an interpolating scheme to project the coefficients to other hole sizes and depths. Additionally, published experimental data are used to extend the coefficients to relatively thin plates. These influence coefficients are used to compute the stresses in the original part from the strain data. HOLEGAGE will compute interior planar stresses using strain data from each drilled hole depth layer. Planar stresses may be computed in three ways including: a least squares fit for a linear variation with depth, an integral method to give incremental stress data for each layer, or by a linear fit to the integral data (with some surface data points omitted) to predict surface stresses before

  20. [ZHENG's gold hook fishing acupuncture for lumbar disc herniation: a clinical observation].

    PubMed

    Zhu, Bowen; Zhang, Xinghua; Sun, Runjie; Qin, Xiaoguang

    2016-04-01

    To compare the clinical efficacy differences between Zheng's gold hook, fishing acupuncture and electroacupuncture (EA) for lumbar disc herniation (LDH). Sixty patients of LDH were randomly allocated to a gold hook fishing acupuncture group and an EA group, 30 cases in each one. Lumbar Jiaji (EX-1 B 2), Yaoyangguan (GV 3), Shenshu (BL 23), Dachangshu (BL 25), Guanyuanshu (BL 26) and ashi points were selected in the gold hook fishing acupuncture group; after the needles were inserted, the manipulation of gold hook fishing acupuncture was applied at tendon junction points and ashi points. The identical acupoints were selected in the EA group and patients were treated with EA. The treatment was both given once a day; ten days of treatment were taken as one session, and totally 3 sessions were given. The clinical effective rate, visual analogue scale (VAS), low back pain score and Oswestry disability index (ODI) were used for efficacy evaluation. The effective rate was 93.3% (28/30) in the gold hook fishing acupuncture group, which was superior to 86.7% (26/30) in the EA group (P < 0.05). The VAS, low back pain score and ODI were both significantly improved after treatment (all P < 0.05), which were more significant in the gold hook fishing acupuncture group (all P < 0.05). ZHENG's gold hook fishing acupuncture could effectively improve the symptoms and sings of LDH, reduce the disability index and improve the quality of life, which is superior to EA.

  1. Vicious Circles in Organizations.

    ERIC Educational Resources Information Center

    Masuch, Michael

    1985-01-01

    After examining some elementary notions of action theory and cybernetics, this article analyzes the dynamics, clustering, and survival chances of vicious circles. It argues that the action perspective implies that many structural suboptimalities of organizations are caused by vicious circles. Eleven figures and 105 references are provided. (DCS)

  2. Effects of hook plate on shoulder function after treatment of acromioclavicular joint dislocation.

    PubMed

    Chen, Chang-Hong; Dong, Qi-Rong; Zhou, Rong-Kui; Zhen, Hua-Qing; Jiao, Ya-Jun

    2014-01-01

    Internal fixation with hook plate has been used to treat acromioclavicular joint dislocation. This study aims to evaluate the effect of its use on shoulder function, to further analyze the contributing factors, and provide a basis for selection and design of improved internal fixation treatment of the acromioclavicular joint dislocation in the future. A retrospective analysis was performed on patients treated with a hook plate for acromioclavicular joint dislocation in our hospital from January 2010 to February 2013. There were 33 cases in total, including 25 males and 8 females, with mean age of 48.27 ± 8.7 years. There were 29 cases of Rockwood type III acromioclavicular dislocation, 4 cases of type V. The Constant-Murley shoulder function scoring system was used to evaluate the shoulder function recovery status after surgery. Anteroposterior shoulder X-ray was used to assess the position of the hook plate, status of acromioclavicular joint reduction and the occurrence of postoperative complications. According to the Constant-Murley shoulder function scoring system, the average scores were 78 ± 6 points 8 to 12 months after the surgery and before the removal of the hook plate, the average scores were 89 ± 5 minutes two months after the removal of hook plate. Postoperative X-ray imaging showed osteolysis in 10 cases (30.3%), osteoarthritis in six cases (18.1%), osteolysis associated with osteoarthritis in four cases(12.1%), and steel hook broken in one case (3%). The use of hook plate on open reduction and internal fixation of the acromioclavicular joint dislocation had little adverse effect on shoulder function and is an effective method for the treatment of acromioclavicular joint dislocation. Osteoarthritis and osteolysis are the two common complications after hook plate use, which are associated with the impairment of shoulder function. Shoulder function will be improved after removal of the hook plate.

  3. Covariant Formulation of Hooke's Law.

    ERIC Educational Resources Information Center

    Gron, O.

    1981-01-01

    Introducing a four-vector strain and a four-force stress, Hooke's law is written as a four-vector equation. This formulation is shown to clarify seemingly paradoxical results in connection with uniformly accelerated motion, and rotational motion with angular acceleration. (Author/JN)

  4. High-dose hook effect in six automated human chorionic gonadotrophin assays.

    PubMed

    Al-Mahdili, Huda A; Jones, Graham R D

    2010-07-01

    The high-dose hook effect is a well-known phenomenon of two-site immunoassays including those for human chorionic gonadotrophin (hCG). We investigated the occurrence of a high-dose hook effect in six routinely available hCG assays using a sample with a total hCG concentration of approximately 3,600,000 IU/L. Dilutions of a sample with high hCG concentration were analysed using six common methods: Advia Centaur, Immulite 2000, Dimension RxL, Unicel DxI 800, Roche E170 and Abbott Architect. The measured concentrations and corresponding assay signals were obtained for each method. Performance was compared with manufacturer claims. Four of the tested platforms demonstrated a clear high-dose hook effect, while the other methods showed no hook effect at the highest level tested. Our results indicate that the hook effect may occur in some hCG assays, although the risk of reporting falsely low results was in most cases at higher concentrations than those indicated in manufacturers' product information. Assay design plays a major role in its occurrence. Laboratories should be aware of the assay limitations in this regard.

  5. Morphological analysis of acromion and hook plate for the fixation of acromioclavicular joint dislocation.

    PubMed

    Yoon, Jong Pil; Lee, Yeon Soo; Song, Geun Soo; Oh, Joo Han

    2017-03-01

    Acromioclavicular (AC) joint dislocation is a common sports injury. Hook plate fixation is currently widely used to treat this injury, as it can promote the natural healing of the ligament with good clinical outcomes. However, subacromial erosion and impingement are frequently observed post-operatively. It was hypothesized that the morphology and the contact characteristics between the hook portion and the acromion are the main causes of complications after hook plate fixation with the currently available commercial designs. Three-dimensional reconstructed models of the AC joint obtained from the computed tomographic scans of 23 male and 23 female patients (mean age, 61.1 ± 6.3 years) were evaluated, and multiple anatomical parameters were measured. For the subacromial positioning of the hook plate, an actual hook plate (Synthes Inc., West Chester, PA, USA) was scanned, and the contact between the hook plate and the acromion was estimated. The thicknesses of the acromion and distal clavicle were 9.7 ± 1.5 mm (10.7 mm in men; 8.6 mm in women) and 11.3 ± 1.6 mm (11.6 mm in men; 10.0 mm in women), respectively. The width of the acromion was 28.5 ± 3.6 mm. The mean inclination angle between the hook plate and the acromion was 29.3° ± 9.7° (27.9° in men; 30.6° in women). The hook plate made a point contact with the acromion at 9.2 ± 3.3 mm (31.5 %) from the lateral end of the acromion. The results revealed that the hook made a pinpoint contact with the undersurface of the acromion, and this might explain why complications commonly occur after hook plate fixation. The force concentration phenomenon associated with the hook plate of existing designs results from cases of morphological mismatch, such as excessive inclination and improper occupation of the subacromial space.

  6. An experimental 'Life' for an experimental life: Richard Waller's biography of Robert Hooke (1705).

    PubMed

    Moxham, Noah

    2016-03-01

    Richard Waller's 'Life of Dr Robert Hooke', prefixed to his edition of Hooke's Posthumous Works (1705), is an important source for the life of one of the most eminent members of the early Royal Society. It also has the distinction of being one of the earliest biographies of a man of science to be published in English. I argue that it is in fact the first biography to embrace the subject's natural-philosophical work as the centre of his life, and I investigate Waller's reasons for adopting this strategy and his struggle with the problem of how to represent an early experimental philosopher in print. I suggest that Waller eschews the 'Christian philosopher' tradition of contemporary biography - partly because of the unusually diverse and fragmentary nature of Hooke's intellectual output - and draws instead upon the structure of the Royal Society's archive as a means of organizing and understanding Hooke's life. The most quoted phrase from Waller's biography is that Hooke became 'to a crime close and reserved' in later life; this essay argues that Waller's biographical sketch was fashioned in order to undo the effects of that reserve. In modelling his approach very closely on the structure of the society's records he was principally concerned with making Hooke's work and biography accessible, intelligible and useful to the fellowship in a context familiar to them, a context which had provided the institutional framework for most of Hooke's adult life. I argue that Waller's 'Life' was also intended to make the largest claims for Hooke's intellectual standing that the author dared in the context of the enmity between Hooke and Isaac Newton once the latter became president of the Royal Society. However, I also adduce fresh manuscript evidence that Waller actually compiled, but did not publish, a defence of Hooke's claim to have discovered the inverse square law of gravity, allowing us to glimpse a much more assertive biography of Hooke than the published version.

  7. Clavicular hook plate for grade-III acromioclavicular dislocation.

    PubMed

    Steinbacher, Gilbert; Sallent, Andrea; Seijas, Roberto; Boffa, Juan Manuel; Espinosa, Wenceslao; Cugat, Ramón

    2014-12-01

    To review the outcomes of clavicular hook plate fixation for grade-III acromioclavicular (AC) dislocation in young athletes. Medical records of 14 male and 5 female athletes aged 18 to 49 (mean, 29) years who underwent fixation with a 3.5-mm-thick, 15-mm-long clavicular hook plate for acute grade-III AC dislocation were reviewed. The visual analogue score for pain and the Constant shoulder score were assessed. The mean follow-up was 4.2 years. The mean visual analogue score for pain was 1.8 (range, 1-3). The Constant shoulder score was excellent (≥ 90) in 14 patients and good (83-89) in 5 patients. All patients achieved range of motion equal to that of the contralateral side at week 5. Sports activities were resumed by month 6 at the latest. The clavicular hook plate for grade- III AC dislocation enables quick return to sports activities and achieves good-to-excellent functional outcome.

  8. When Teachers Aren't Nice: bell hooks and Feminist Pedagogy.

    ERIC Educational Resources Information Center

    Buffington, Nancy

    The recent "feminization" of composition theory and pedagogy has replaced the classroom figure of the authoritative father with an image of a nurturing mother. But as bell hooks and others insist, the classroom is inherently a place of struggle and conflict and the "real world" is even more so. Hooks offers concrete…

  9. Literature Circles. ERIC Digest.

    ERIC Educational Resources Information Center

    Lin, Chia-Hui

    The use of literature circles has been discussed in a variety of academic journals, conference papers, and workshops. Teachers at all grade levels use literature circles as a vehicle through which students learn to: think critically about literature; express their thoughts in oral and written forms; and better enjoy their literacy experiences.…

  10. Detection and Use of Load and Gage Output Repeats of Wind Tunnel Strain-Gage Balance Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.

    2017-01-01

    Criteria are discussed that may be used for the detection of load and gage output repeats of wind tunnel strain-gage balance data. First, empirical thresholds are introduced that help determine if the loads or electrical outputs of a pair of balance calibration or check load data points match. A threshold of 0.01 percent of the load capacity is suggested for the identification of matching loads. Similarly, a threshold of 0.1 microV/V is recommended for the identification of matching electrical outputs. Two examples for the use of load and output repeats are discussed to illustrate benefits of the implementation of a repeat point detection algorithm in a balance data analysis software package. The first example uses the suggested load threshold to identify repeat data points that may be used to compute pure errors of the balance loads. This type of analysis may reveal hidden data quality issues that could potentially be avoided by making calibration process improvements. The second example uses the electrical output threshold for the identification of balance fouling. Data from the calibration of a six-component force balance is used to illustrate the calculation of the pure error of the balance loads.

  11. Evaluation of the orientation of 90* and 180* reinforcing bar hooks.

    DOT National Transportation Integrated Search

    2012-01-01

    This report describes test results of a study initiated to evaluate the potential influence of hook tilt angle of standard reinforcing hooks : on the bond strength of concrete. The topic of the evaluation of the orientation of 90 and 180 degree reinf...

  12. Analysis of the streamflow-gaging station network in Ohio for effectiveness in providing regional streamflow information

    USGS Publications Warehouse

    Straub, D.E.

    1998-01-01

    The streamflow-gaging station network in Ohio was evaluated for its effectiveness in providing regional streamflow information. The analysis involved application of the principles of generalized least squares regression between streamflow and climatic and basin characteristics. Regression equations were developed for three flow characteristics: (1) the instantaneous peak flow with a 100-year recurrence interval (P100), (2) the mean annual flow (Qa), and (3) the 7-day, 10-year low flow (7Q10). All active and discontinued gaging stations with 5 or more years of unregulated-streamflow data with respect to each flow characteristic were used to develop the regression equations. The gaging-station network was evaluated for the current (1996) condition of the network and estimated conditions of various network strategies if an additional 5 and 20 years of streamflow data were collected. Any active or discontinued gaging station with (1) less than 5 years of unregulated-streamflow record, (2) previously defined basin and climatic characteristics, and (3) the potential for collection of more unregulated-streamflow record were included in the network strategies involving the additional 5 and 20 years of data. The network analysis involved use of the regression equations, in combination with location, period of record, and cost of operation, to determine the contribution of the data for each gaging station to regional streamflow information. The contribution of each gaging station was based on a cost-weighted reduction of the mean square error (average sampling-error variance) associated with each regional estimating equation. All gaging stations included in the network analysis were then ranked according to their contribution to the regional information for each flow characteristic. The predictive ability of the regression equations developed from the gaging station network could be improved for all three flow characteristics with the collection of additional streamflow data

  13. Polygons and Their Circles

    ERIC Educational Resources Information Center

    Stephenson, Paul

    2009-01-01

    In order to find its circumference, Archimedes famously boxed the circle between two polygons. Ending the first of a series of articles (MT179) with an aside, Francis Lopez-Real reverses the situation to ask: Which polygons can be boxed between two circles? (The official term for such polygons is "bicentric".) The sides of these polygons are…

  14. Identifying dissolved organic carbon sources at a gaged headwater catchment using FDOM sensors

    NASA Astrophysics Data System (ADS)

    Malzone, J. M.; Shanley, J. B.

    2014-12-01

    The United States Geological Survey's (USGS) W-9 gage at the headwaters of Sleepers River, Vermont has been monitored for dissolved organic carbon (DOC) concentration for more than 20 years. However, the sources of this DOC during base flow and hydrologic events remain unclear. The major objectives of this research were to identify sources of DOC during storm events and to explain the observed DOC-streamflow counterclockwise hysteresis during hydrologic events. Two main hypotheses to explain hysteresis during hydrologic events were tested: (1) distant headwater wetlands are the major DOC source, which lags behind peak flow due to travel time; and (2) the entire watershed contributes to the DOC at the gage, but the response of DOC lags behind the period when groundwater contributes most to streamflow. Sources of DOC were tracked using fluorescent dissolved organic matter (FDOM) sensors in surface water and groundwater wells. Wells were installed at four depths, 0.3, 0.6, 0.9, and 1.2 m, at four sites: a peaty low-gradient riparian area near the headwaters; a mid-hillslope area on a long hillslope mid-watershed; a near-stream area on a long hillslope mid-watershed; and a low-gradient tributary confluence area just above the gage. During storm events, FDOM and hydraulic head were measured at the nested groundwater wells. Samples for DOC analysis were also taken to determine the relationship between FDOM and DOC. Results suggest that both distant sources and the greater watershed played a role in the transport of DOC to the W-9 gage. Distant peaty sources dominated during large storms and contributed the highest surface water FDOM measurements. The peak FDOM at the gage was therefore best described as a result of transport. However, export from these distant sources terminated rapidly and did not explain continued elevated FDOM at the gage. Groundwater across the watershed exhibited hysteresis analogous to that in the stream itself, with FDOM peaking as head receded

  15. Flagellar Hook Flexibility Is Essential for Bundle Formation in Swimming Escherichia coli Cells

    PubMed Central

    Brown, Mostyn T.; Steel, Bradley C.; Silvestrin, Claudio; Wilkinson, David A.; Delalez, Nicolas J.; Lumb, Craig N.; Obara, Boguslaw; Berry, Richard M.

    2012-01-01

    Swimming Escherichia coli cells are propelled by the rotary motion of their flagellar filaments. In the normal swimming pattern, filaments positioned randomly over the cell form a bundle at the posterior pole. It has long been assumed that the hook functions as a universal joint, transmitting rotation on the motor axis through up to ∼90° to the filament in the bundle. Structural models of the hook have revealed how its flexibility is expected to arise from dynamic changes in the distance between monomers in the helical lattice. In particular, each of the 11 protofilaments that comprise the hook is predicted to cycle between short and long forms, corresponding to the inside and outside of the curved hook, once each revolution of the motor when the hook is acting as a universal joint. To test this, we genetically modified the hook so that it could be stiffened by binding streptavidin to biotinylated monomers, impeding their motion relative to each other. We found that impeding the action of the universal joint resulted in atypical swimming behavior as a consequence of disrupted bundle formation, in agreement with the universal joint model. PMID:22522898

  16. Characteristics of Extrinsic Fabry-Perot Interferometric (EFPI) Fiber-Optic Strain Gages

    NASA Technical Reports Server (NTRS)

    Hare, David A.; Moore, Thomas C., Sr.

    2000-01-01

    The focus of this paper is a comparison of the strain-measuring characteristics of one type of commercially available fiber-optic strain sensor with the performance of conventional resistance strain gages. Fabry-Perot type fiber-optic strain sensors were selected for this testing program. Comparative testing is emphasized and includes load testing at room temperature with apparent strain characterization cryogenically and at elevated temperatures. The absolute accuracy of either of these types of strain gages is not addressed.

  17. 77 FR 15722 - Southern California Hook and Line Survey; Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-16

    ... meeting to evaluate the Southern California Shelf Rockfish Hook and Line Survey which was designed to... and Line survey design and protocols; (2) examine the analytical methods used to generate rockfish... California Hook and Line Survey; Public Meeting AGENCY: National Marine Fisheries Service (NMFS), National...

  18. Evaluation of a nuclear gage for controlling the consolidation of fresh concrete : final report.

    DOT National Transportation Integrated Search

    1981-01-01

    Evaluated was an approach to controlling the consolidation of in-place portland cement concrete on the basis of densities obtained with a Troxler 3411 nuclear gage. The gage was used in the backscatter mode on low-slump concrete bridge deck overlays ...

  19. Amplification of telomeric arrays via rolling-circle mechanism.

    PubMed

    Nosek, Jozef; Rycovska, Adriana; Makhov, Alexander M; Griffith, Jack D; Tomaska, Lubomir

    2005-03-18

    Alternative (telomerase-independent) lengthening of telomeres mediated through homologous recombination is often accompanied by a generation of extrachromosomal telomeric circles (t-circles), whose role in direct promotion of recombinational telomere elongation has been recently demonstrated. Here we present evidence that t-circles in a natural telomerase-deficient system of mitochondria of the yeast Candida parapsilosis replicate independently of the linear chromosome via a rolling-circle mechanism. This is supported by an observation of (i) single-stranded DNA consisting of concatameric arrays of telomeric sequence, (ii) lasso-shaped molecules representing rolling-circle intermediates, and (iii) preferential incorporation of deoxyribonucleotides into telomeric fragments and t-circles. Analysis of naturally occurring variant t-circles revealed conserved motifs with potential function in driving the rolling-circle replication. These data indicate that extrachromosomal t-circles observed in a wide variety of organisms, including yeasts, plants, Xenopus laevis, and certain human cell lines, may represent independent replicons generating telomeric sequences and, thus, actively participating in telomere dynamics. Moreover, because of the promiscuous occurrence of t-circles across phyla, the results from yeast mitochondria have implications related to the primordial system of telomere maintenance, providing a paradigm for evolution of telomeres in nuclei of early eukaryotes.

  20. Mapping connectivity damage in the case of Phineas Gage.

    PubMed

    Van Horn, John Darrell; Irimia, Andrei; Torgerson, Carinna M; Chambers, Micah C; Kikinis, Ron; Toga, Arthur W

    2012-01-01

    White matter (WM) mapping of the human brain using neuroimaging techniques has gained considerable interest in the neuroscience community. Using diffusion weighted (DWI) and magnetic resonance imaging (MRI), WM fiber pathways between brain regions may be systematically assessed to make inferences concerning their role in normal brain function, influence on behavior, as well as concerning the consequences of network-level brain damage. In this paper, we investigate the detailed connectomics in a noted example of severe traumatic brain injury (TBI) which has proved important to and controversial in the history of neuroscience. We model the WM damage in the notable case of Phineas P. Gage, in whom a "tamping iron" was accidentally shot through his skull and brain, resulting in profound behavioral changes. The specific effects of this injury on Mr. Gage's WM connectivity have not previously been considered in detail. Using computed tomography (CT) image data of the Gage skull in conjunction with modern anatomical MRI and diffusion imaging data obtained in contemporary right handed male subjects (aged 25-36), we computationally simulate the passage of the iron through the skull on the basis of reported and observed skull fiducial landmarks and assess the extent of cortical gray matter (GM) and WM damage. Specifically, we find that while considerable damage was, indeed, localized to the left frontal cortex, the impact on measures of network connectedness between directly affected and other brain areas was profound, widespread, and a probable contributor to both the reported acute as well as long-term behavioral changes. Yet, while significantly affecting several likely network hubs, damage to Mr. Gage's WM network may not have been more severe than expected from that of a similarly sized "average" brain lesion. These results provide new insight into the remarkable brain injury experienced by this noteworthy patient.

  1. Rolling-circle amplification under topological constraints

    PubMed Central

    Kuhn, Heiko; Demidov, Vadim V.; Frank-Kamenetskii, Maxim D.

    2002-01-01

    We have performed rolling-circle amplification (RCA) reactions on three DNA templates that differ distinctly in their topology: an unlinked DNA circle, a linked DNA circle within a pseudorotaxane-type structure and a linked DNA circle within a catenane. In the linked templates, the single-stranded circle (dubbed earring probe) is threaded, with the aid of two peptide nucleic acid openers, between the two strands of double-stranded DNA (dsDNA). We have found that the RCA efficiency of amplification was essentially unaffected when the linked templates were employed. By showing that the DNA catenane remains intact after RCA reactions, we prove that certain DNA polymerases can carry out the replicative synthesis under topological constraints allowing detection of several hundred copies of a dsDNA marker without DNA denaturation. Our finding may have practical implications in the area of DNA diagnostics. PMID:11788721

  2. Effects of hook plate on shoulder function after treatment of acromioclavicular joint dislocation

    PubMed Central

    Chen, Chang-Hong; Dong, Qi-Rong; Zhou, Rong-Kui; Zhen, Hua-Qing; Jiao, Ya-Jun

    2014-01-01

    Introduction: Internal fixation with hook plate has been used to treat acromioclavicular joint dislocation. This study aims to evaluate the effect of its use on shoulder function, to further analyze the contributing factors, and provide a basis for selection and design of improved internal fixation treatment of the acromioclavicular joint dislocation in the future. Methods: A retrospective analysis was performed on patients treated with a hook plate for acromioclavicular joint dislocation in our hospital from January 2010 to February 2013. There were 33 cases in total, including 25 males and 8 females, with mean age of 48.27 ± 8.7 years. There were 29 cases of Rockwood type III acromioclavicular dislocation, 4 cases of type V. The Constant-Murley shoulder function scoring system was used to evaluate the shoulder function recovery status after surgery. Anteroposterior shoulder X-ray was used to assess the position of the hook plate, status of acromioclavicular joint reduction and the occurrence of postoperative complications. Results: According to the Constant-Murley shoulder function scoring system, the average scores were 78 ± 6 points 8 to 12 months after the surgery and before the removal of the hook plate, the average scores were 89 ± 5 minutes two months after the removal of hook plate. Postoperative X-ray imaging showed osteolysis in 10 cases (30.3%), osteoarthritis in six cases (18.1%), osteolysis associated with osteoarthritis in four cases(12.1%), and steel hook broken in one case (3%). Conclusion: The use of hook plate on open reduction and internal fixation of the acromioclavicular joint dislocation had little adverse effect on shoulder function and is an effective method for the treatment of acromioclavicular joint dislocation. Osteoarthritis and osteolysis are the two common complications after hook plate use, which are associated with the impairment of shoulder function. Shoulder function will be improved after removal of the hook plate. PMID

  3. Removal of a barbed fish hook from the cornea of an 8-year-old boy.

    PubMed

    Kemp, Pavlina S; Shah, Ankoor S; Elliott, Alexandra T; Wan, Michael J

    2017-10-01

    This video article shows the surgical removal of a three-pronged barbed fish hook from the cornea and anterior chamber of an 8-year-old boy. The advance-and-cut method is shown: the embedded barbed point of the fish hook was advanced through the cornea, its point was cut off, and the shank of the hook was withdrawn. This method was chosen due to the three-pronged configuration of the fish hook to minimize additional trauma to the eye. Other methods of fish hook removal are briefly reviewed. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  4. Are College Students Replacing Dating and Romantic Relationships with Hooking Up?

    ERIC Educational Resources Information Center

    Siebenbruner, Jessica

    2013-01-01

    This study assessed female college students' ("N" = 197) participation in dating, romantic relationships, hooking up behaviors, and the intersection of these activities. Hooking up was prevalent among students ("n" = 78; 39.6%), but dating ("n" = 139; 70.6%) and romantic relationship ("n" = 147; 74.6%)…

  5. Quality circles: Organizational adaptations, improvements and results

    NASA Technical Reports Server (NTRS)

    Tortorich, R.

    1985-01-01

    The effective application in industry and government of quality circles work was demonstrated. The results achieved in quality and productivity improvements and cost savings are impressive. The circle process should be institutionalized within industry and government. The stages of circle program growth, innovations that help achieve circle process institutionalization, and the result achieved at Martin Marietta's Michoud Division and within the National Aeronautics and Space Administration (NASA) are addressed.

  6. Fluidically Controlled Cargo Hook

    DTIC Science & Technology

    1975-03-01

    Final Breadboard Fluidic Circuit IT 6 External Cargo Handling System - Cü-Sk Type Aircraft 18 7 Back Pressure Switch Response Time - Switching...On 20 8 Back Pressure Switch Response Time - Switching Off 21 9 Hook Actuator - Pressure Rise Rate 22 10 Breadboard Fluidic System Component...LINE LENGTH* FT Figure 7« Back. Pressure Switch Response Time - Switching On. ! TABLE k. INTERFACE VALVE SIGNAL TIME

  7. The newest miracle drug: quality circles in hospitals.

    PubMed

    McKinney, M M

    1984-01-01

    In recent years, a number of hospitals throughout the United States have been exploring the use of Japanese-style quality circles to reduce their operating expenses, improve productivity, and enhance the quality of work life for hospital employees. This article examines the organizational climate necessary for quality circles, methods used to implement quality circles, and management's role in guiding and responding to circle activities. Ideas for building and maintaining staff support are presented along with a cost/benefit analysis of quality circle programs. The author concludes that quality circles are most successful in hospitals where they are part of a larger organizational development effort. When administrators believe in their employees' ability to contribute to the institution and are willing to invest necessary time and resources in employee education and the measurement of quality circle achievements, quality circles can produce creative solutions to perplexing institutional problems.

  8. Calibration of strain-gage installations in aircraft structures for the measurement of flight loads

    NASA Technical Reports Server (NTRS)

    Skopinski, T H; Aiken, William S , Jr; Huston, Wilber B

    1954-01-01

    A general method has been developed for calibrating strain-gage installations in aircraft structures, which permits the measurement in flight of the shear or lift, the bending moment, and the torque or pitching moment on the principal lifting or control surfaces. Although the stress in structural members may not be a simple function of the three loads of interest, a straightforward procedure is given for numerically combining the outputs of several bridges in such a way that the loads may be obtained. Extensions of the basic procedure by means of electrical combination of the strain-gage bridges are described which permit compromises between strain-gage installation time, availability of recording instruments, and data reduction time. The basic principles of strain-gage calibration procedures are illustrated by reference to the data for two aircraft structures of typical construction, one a straight and the other a swept horizontal stabilizer.

  9. Cost-effectiveness of the streamflow-gaging program in Wyoming

    USGS Publications Warehouse

    Druse, S.A.; Wahl, K.L.

    1988-01-01

    This report documents the results of a cost-effectiveness study of the streamflow-gaging program in Wyoming. Regression analysis or hydrologic flow-routing techniques were considered for 24 combinations of stations from a 139-station network operated in 1984 to investigate suitability of techniques for simulating streamflow records. Only one station was determined to have sufficient accuracy in the regression analysis to consider discontinuance of the gage. The evaluation of the gaging-station network, which included the use of associated uncertainty in streamflow records, is limited to the nonwinter operation of the 47 stations operated by the Riverton Field Office of the U.S. Geological Survey. The current (1987) travel routes and measurement frequencies require a budget of $264,000 and result in an average standard error in streamflow records of 13.2%. Changes in routes and station visits using the same budget, could optimally reduce the standard error by 1.6%. Budgets evaluated ranged from $235,000 to $400,000. A $235,000 budget increased the optimal average standard error/station from 11.6 to 15.5%, and a $400,000 budget could reduce it to 6.6%. For all budgets considered, lost record accounts for about 40% of the average standard error. (USGS)

  10. Cost-effectiveness of the stream-gaging program in Maine; a prototype for nationwide implementation

    USGS Publications Warehouse

    Fontaine, Richard A.; Moss, M.E.; Smath, J.A.; Thomas, W.O.

    1984-01-01

    This report documents the results of a cost-effectiveness study of the stream-gaging program in Maine. Data uses and funding sources were identified for the 51 continuous stream gages currently being operated in Maine with a budget of $211,000. Three stream gages were identified as producing data no longer sufficiently needed to warrant continuing their operation. Operation of these stations should be discontinued. Data collected at three other stations were identified as having uses specific only to short-term studies; it is recommended that these stations be discontinued at the end of the data-collection phases of the studies. The remaining 45 stations should be maintained in the program for the foreseeable future. The current policy for operation of the 45-station program would require a budget of $180,300 per year. The average standard error of estimation of streamflow records is 17.7 percent. It was shown that this overall level of accuracy at the 45 sites could be maintained with a budget of approximately $170,000 if resources were redistributed among the gages. A minimum budget of $155,000 is required to operate the 45-gage program; a smaller budget would not permit proper service and maintenance of the gages and recorders. At the minimum budget, the average standard error is 25.1 percent. The maximum budget analyzed was $350,000, which resulted in an average standard error of 8.7 percent. Large parts of Maine's interior were identified as having sparse streamflow data. It was determined that this sparsity be remedied as funds become available.

  11. Light exaggerates apical hook curvature through phytochrome actions in tomato seedlings.

    PubMed

    Shichijo, Chizuko; Ohuchi, Hisako; Iwata, Naoko; Nagatoshi, Yukari; Takahashi, Miki; Nakatani, Eri; Inoue, Kentaroh; Tsurumi, Seiji; Tanaka, Osamu; Hashimoto, Tohru

    2010-02-01

    Contrary to the established notion that the apical hook of dark-grown dicotyledonous seedlings opens in response to light, we found in tomato (Solanum lycopersicum L.) that the apical hook curvature is exaggerated by light. Experiments with several tomato cultivars and phytochrome mutants, irradiated with red and far-red light either as a brief pulse (Rp, FRp) or continuously (Rc, FRc), revealed: the hook-exaggeration response is maximal at the emergence of the hypocotyl from the seed; the effect of Rp is FRp-reversible; fluence-response curves to a single Rp or FRp show an involvement of low and very low fluence responses (LFR, VLFR); the effect of Rc is fluence-rate dependent, but that of FRc is not; the phyA mutant (phyA hp-1) failed to respond to an Rp of less than 10(-2) micromol m(-2) and to an FRp of all fluences tested as well as to FRc, thus indicating that the hook-exaggeration response involves phyA-mediated VLFR. The Rp fluence-response curve with the same mutant also confirmed the presence of an LFR mediated by phytochrome(s) other than phyA, although the phyB1 mutant (phyB1 hp-1) still showed full response probably due to other redundant phytochrome species (e.g., phyB2). Simulation experiments led to the possible significance of hook exaggeration in the field that the photoresponse may facilitate the release of seed coat when seeds germinate at some range of depth in soil. It was also observed that seed coat and/or endosperm are essential to the hook exaggeration.

  12. Yoctomole electrochemical genosensing of Ebola virus cDNA by rolling circle and circle to circle amplification.

    PubMed

    Carinelli, S; Kühnemund, M; Nilsson, M; Pividori, M I

    2017-07-15

    This work addresses the design of an Ebola diagnostic test involving a simple, rapid, specific and highly sensitive procedure based on isothermal amplification on magnetic particles with electrochemical readout. Ebola padlock probes were designed to detect a specific L-gene sequence present in the five most common Ebola species. Ebola cDNA was amplified by rolling circle amplification (RCA) on magnetic particles. Further re-amplification was performed by circle-to-circle amplification (C2CA) and the products were detected in a double-tagging approach using a biotinylated capture probe for immobilization on magnetic particles and a readout probe for electrochemical detection by square-wave voltammetry on commercial screen-printed electrodes. The electrochemical genosensor was able to detect as low as 200 ymol, corresponding to 120 cDNA molecules of L-gene Ebola virus with a limit of detection of 33 cDNA molecules. The isothermal double-amplification procedure by C2CA combined with the electrochemical readout and the magnetic actuation enables the high sensitivity, resulting in a rapid, inexpensive, robust and user-friendly sensing strategy that offers a promising approach for the primary care in low resource settings, especially in less developed countries. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. CIRCLE Enhancement After Myopic SMILE.

    PubMed

    Siedlecki, Jakob; Luft, Nikolaus; Mayer, Wolfgang J; Siedlecki, Martin; Kook, Daniel; Meyer, Bertram; Bechmann, Martin; Wiltfang, Rainer; Priglinger, Siegfried G; Dirisamer, Martin

    2018-05-01

    To report the outcomes of enhancement after small incision lenticule extraction (SMILE) using the VisuMax CIRCLE option (Carl Zeiss Meditec AG, Jena, Germany), which converts the SMILE cap into a femtosecond LASIK flap for secondary excimer laser application. Of 2,065 SMILE procedures, 22 eyes (1.1%) re-treated with CIRCLE with a follow-up of 3 months were included in the analysis. SMILE was performed in the usual manner. For re-treatment, the CIRCLE procedure was performed with pattern D flap creation on the VisuMax system and subsequent excimer laser ablation with a Zeiss MEL 90 laser (Carl Zeiss Meditec) with plano target in all cases. Spherical equivalent was -5.56 ± 2.22 diopters (D) before SMILE and -0.51 ± 1.08 D before CIRCLE. CIRCLE enhancement was performed after a mean of 10.0 ± 7.9 months, allowed for safe flap lifting in all eyes, and resulted in a final manifest refraction spherical equivalent of 0.18 ± 0.31 D at 3 months (P < .008). The number of eyes within 0.50 and 1.00 D from target refraction increased from 31.8% to 90.9% and from 77.3% to 100%, respectively. Mean uncorrected distance visual acuity (UDVA) had already improved from 0.37 ± 0.16 to 0.08 ± 0.16 logMAR at 1 week (P < .0001), resulting in 0.03 ± 0.07 logMAR at 3 months (P < .0001). All eyes gained at least one line of UDVA. Corrected distance visual acuity (CDVA) remained unchanged at all time points (before vs after CIRCLE, P = .40). Two eyes (9.1 %) lost one line of CDVA; no eye lost two or more lines. The safety and efficacy indices were 1.03 and 0.97 at 3 months. The CIRCLE procedure represents an effective re-treatment option after SMILE. Compared to surface ablation re-treatment after SMILE, CIRCLE seems to offer advantages in respect to speed of visual recovery, safety, and predictability, but at the price of flap creation. [J Refract Surg. 2018;34(5):304-309.]. Copyright 2018, SLACK Incorporated.

  14. Collaborative Lesson Hook Design in Science Teacher Education: Advancing Professional Practice

    ERIC Educational Resources Information Center

    McCauley, Veronica; Davison, Kevin; Byrne, Corinna

    2015-01-01

    This article documents the process of collaboratively developing lesson hook e-resources for science teachers to establish a community of inquiry and to strengthen the pedagogy of science teaching. The authors aim to illustrate how the development and application of strategic hooks can bridge situational interest and personal interest so that…

  15. Assessing the Personal Negative Impacts of Hooking Up Experienced by College Students: Gender Differences and Mental Health.

    PubMed

    Napper, Lucy E; Montes, Kevin S; Kenney, Shannon R; LaBrie, Joseph W

    2016-09-01

    Hooking up is a normative behavior among college students that is associated with a range of positive and negative consequences. While previous research has primarily focused on women's negative experiences of hooking up, the current study explored the relationships among hooking up behaviors, psychological distress, and a broad range of negative effects of hooking up in both male and female college students. Using a multisite sample of college students, we developed the 14-item Negative Impact of Hookups Inventory (NIHI) to assess negative health outcomes, emotional responses, and social consequences associated with hooking up. Unprotected sex and having more hookup partners were associated with greater negative experiences of hooking up. Contrary to expectations, there were no gender differences in the total number of negative hookup effects, although men reported more frequent hookups. In addition, negative impacts of hooking up were positively associated with psychological distress regardless of gender. The NIHI may offer a useful tool to assess the negative impacts of hooking up. Understanding students' hookup experiences is an important step toward developing targeted health interventions related to hooking up behavior in young adult populations.

  16. Refinement of moisture calibration curves for nuclear gage.

    DOT National Transportation Integrated Search

    1973-01-01

    Over the last three years the Virginia Highway Research Council has directed a research effort toward improving the method of determining the moisture content of soils with a nuclear gage. The first task in this research was the determination of the ...

  17. Introducing Nine-Point Circle to Junior High School Students

    NASA Astrophysics Data System (ADS)

    Fiangga, S.; Azizah, M. A. N.; Rini, R. N. K.; Hidayanti, A. N.

    2018-01-01

    The concept of circles is an ancient concept that has appeared since Ancient Egypt from which this concept gives many significant contributions in mathematics’ development until now. Nevertheless, the concept of circles hides many uncover mysterious features that are of applications in mathematics. One of the mysterious features is the Nine-Point Circle. This Nine-point circle is also known as Euler’s circle, six-point circle, Feuerbach’s circle, the twelve-point circle, and many others. Because of these different names, there have been misunderstand among mathematicians about the Nine-Point Circle’s history. Besides, the discussion of Nine-Point Circle can be used to be an initial material to explain elementary geometry topic in junior high school’s level curriculum of 2013. Therefore, this concept needs to be delivered to the students as a geometry introduction. A possible form of the integration historical aspect of Nine-point circle is suggested in this paper as well as its importance in the curriculum of 2013.

  18. Silicon strain gages bonded on stainless steel using glass frit for strain sensor applications

    NASA Astrophysics Data System (ADS)

    Zhang, Zongyang; Cheng, Xingguo; Leng, Yi; Cao, Gang; Liu, Sheng

    2014-05-01

    In this paper, a steel pressure sensor using strain gages bonded on a 17-4 PH stainless steel (SS) diaphragm based on glass frit technology is proposed. The strain gages with uniform resistance are obtained by growing an epi-silicon layer on a single crystal silicon wafer using epitaxial deposition technique. The inorganic glass frits are used as the bonding material between the strain gages and the 17-4 PH SS diaphragm. Our results show that the output performances of sensors at a high temperature of 125 °C are almost equal those at room temperature, which indicates that the glass frit bonding is a good method and may lead to a significant advance in the high temperature applicability of silicon strain gage sensors. Finally, the microstructure of the cured organic adhesive and the fired glass frit are compared. It may be concluded that the defects of the cured organic adhesive deteriorate the hysteresis and repeatability errors of the sensors.

  19. A New Load Residual Threshold Definition for the Evaluation of Wind Tunnel Strain-Gage Balance Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.; Volden, T.

    2016-01-01

    A new definition of a threshold for the detection of load residual outliers of wind tunnel strain-gage balance data was developed. The new threshold is defined as the product between the inverse of the absolute value of the primary gage sensitivity and an empirical limit of the electrical outputs of a strain{gage. The empirical limit of the outputs is either 2.5 microV/V for balance calibration or check load residuals. A reduced limit of 0.5 microV/V is recommended for the evaluation of differences between repeat load points because, by design, the calculation of these differences removes errors in the residuals that are associated with the regression analysis of the data itself. The definition of the new threshold and different methods for the determination of the primary gage sensitivity are discussed. In addition, calibration data of a six-component force balance and a five-component semi-span balance are used to illustrate the application of the proposed new threshold definition to different types of strain{gage balances. During the discussion of the force balance example it is also explained how the estimated maximum expected output of a balance gage can be used to better understand results of the application of the new threshold definition.

  20. 33 CFR 80.170 - Sandy Hook, NJ to Tom's River, NJ.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Sandy Hook, NJ to Tom's River, NJ. 80.170 Section 80.170 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES COLREGS DEMARCATION LINES Atlantic Coast § 80.170 Sandy Hook, NJ to Tom's River...

  1. Fluid quantity gaging

    NASA Technical Reports Server (NTRS)

    Mord, Allan J.; Snyder, Howard A.; Kilpatrick, Kathleen A.; Hermanson, Lynn A.; Hopkins, Richard A.; Vangundy, Donald A.

    1988-01-01

    A system for measuring the mass of liquid in a tank on orbit with 1 percent accuracy was developed and demonstrated. An extensive tradeoff identified adiabatic compression as the only gaging technique that is independent of gravity or its orientation, and of the size and distribution of bubbles in the tank. This technique is applicable to all Earth-storable and cryogenic liquids of interest for Space Station use, except superfluid helium, and can be applied to tanks of any size, shape, or internal structure. Accuracy of 0.2 percent was demonstrated in the laboratory, and a detailed analytical model was developed and verified by testing. A flight system architecture is presented that allows meeting the needs of a broad range of space fluid systems without custom development for each user.

  2. Low TCR nanocomposite strain gages

    NASA Technical Reports Server (NTRS)

    Gregory, Otto J. (Inventor); Chen, Ximing (Inventor)

    2012-01-01

    A high temperature thin film strain gage sensor capable of functioning at temperatures above 1400.degree. C. The sensor contains a substrate, a nanocomposite film comprised of an indium tin oxide alloy, zinc oxide doped with alumina or other oxide semiconductor and a refractory metal selected from the group consisting of Pt, Pd, Rh, Ni, W, Ir, NiCrAlY and NiCoCrAlY deposited onto the substrate to form an active strain element. The strain element being responsive to an applied force.

  3. Wind Tunnel Strain-Gage Balance Calibration Data Analysis Using a Weighted Least Squares Approach

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.; Volden, T.

    2017-01-01

    A new approach is presented that uses a weighted least squares fit to analyze wind tunnel strain-gage balance calibration data. The weighted least squares fit is specifically designed to increase the influence of single-component loadings during the regression analysis. The weighted least squares fit also reduces the impact of calibration load schedule asymmetries on the predicted primary sensitivities of the balance gages. A weighting factor between zero and one is assigned to each calibration data point that depends on a simple count of its intentionally loaded load components or gages. The greater the number of a data point's intentionally loaded load components or gages is, the smaller its weighting factor becomes. The proposed approach is applicable to both the Iterative and Non-Iterative Methods that are used for the analysis of strain-gage balance calibration data in the aerospace testing community. The Iterative Method uses a reasonable estimate of the tare corrected load set as input for the determination of the weighting factors. The Non-Iterative Method, on the other hand, uses gage output differences relative to the natural zeros as input for the determination of the weighting factors. Machine calibration data of a six-component force balance is used to illustrate benefits of the proposed weighted least squares fit. In addition, a detailed derivation of the PRESS residuals associated with a weighted least squares fit is given in the appendices of the paper as this information could not be found in the literature. These PRESS residuals may be needed to evaluate the predictive capabilities of the final regression models that result from a weighted least squares fit of the balance calibration data.

  4. Clip gage attachment for frictionless measurement of displacement during high-temperature mechanical testing

    DOEpatents

    Alexander, David J.

    1994-01-01

    An attachment for placement between a test specimen and a remote clip gage extensometer providing improved fracture toughness tests of materials at elevated temperature. Using a cylindrical tube and axial rod in new relationship, the device transfers the displacement signal of the fracture toughness test specimen directly to a clip gage extensometer located outside the high temperature furnace. Virtually frictionless operation is assured by having the test specimen center one end of the rod in one end of the tube, while the clip gage extensometer arms center the other end of the rod in the other end of the tube. By providing positive control over both ends of both rod and tube, the attachment may be operated in orientations other than vertical.

  5. Clip gage attachment for frictionless measurement of displacement during high-temperature mechanical testing

    DOEpatents

    Alexander, D.J.

    1994-01-04

    An attachment for placement between a test specimen and a remote clip gage extensometer providing improved fracture toughness tests of materials at elevated temperature is described. Using a cylindrical tube and axial rod in new relationship, the device transfers the displacement signal of the fracture toughness test specimen directly to a clip gage extensometer located outside the high temperature furnace. Virtually frictionless operation is assured by having the test specimen center one end of the rod in one end of the tube, while the clip gage extensometer arms center the other end of the rod in the other end of the tube. By providing positive control over both ends of both rod and tube, the attachment may be operated in orientations other than vertical. 1 figure.

  6. The Director Circle of a Central Conic Section

    ERIC Educational Resources Information Center

    Ayoub, Ayoub B.

    2007-01-01

    Each ellipse and hyperbola has a circle associated with it called the director circle. In this article, the author derives the equations of the circle for the ellipse and hyperbola through a different approach. Then the author concentrates on the director circle of the central conic given by the general quadratic equation. The content of this…

  7. In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables.

    PubMed

    Hitchon, Patrick W; Brenton, Matthew D; Black, Andrew G; From, Aaron; Harrod, Jeremy S; Barry, Christopher; Serhan, Hassan; Torner, James C

    2003-07-01

    Three types of posterior thoracolumbar implants are in use today: pedicle screws, sublaminar titaniumcables, and sublaminar hooks. The authors conducted a biomechanical comparison of these three implants in human cadaveric spines. Spine specimens (T5-12) were harvested, radiographically assessed for fractures or metastases, and their bone mineral density (BMD) was measured. Individual vertebrae were disarticulated and fitted with either pedicle screws, sublaminar cables, or bilateral claw hooks. The longitudinal component of each construct consisted of bilateral 10-cm rods connected with two cross-connectors. The vertebral body was embedded in cement, and the rods were affixed to a ball-and-socket apparatus for the application of a distraction force. The authors analyzed 1) 20 vertebrae implanted with screws; 2) 20 with hooks, and 3) 20 with cables. The maximum pullout (MPO) forces prior to failure (mean +/- standard deviation) for the screw, hook, and cable implants were 972 +/- 330, 802 +/- 356, and 654 +/- 248 N, respectively (p = 0.0375). Cables allowed significantly greater displacement (6.80 +/- 3.95 mm) prior to reaching the MPO force than hooks (3.73 +/- 1.42 mm) and screws (4.42 +/- 2.15 mm [p = 0.0108]). Eleven screw-implanted vertebrae failed because of screw pullout. All hook-and-cable-implanted vertebrae failed because of pedicle, middle column, or laminar fracture. These findings suggest that screws possess the greatest pullout strength of the three fixation systems. Sublaminar cables are the least rigid of the three. When screw failure occurred, the mechanism was generally screw back-out, without vertebral fractures.

  8. Quality/Performance Circles Three Years after Implementation.

    ERIC Educational Resources Information Center

    Ladwig, Dennis J.

    An overview is provided of the development of quality/performance circles at Lakeshore Technical Institute (LTI), Wisconsin, and of the projects undertaken through the quality/performance circle program during its 3-year history. First, background information is provided on the use of quality circles in Japan and the United States, including…

  9. Evaluation of the cost effectiveness of the 1983 stream-gaging program in Kansas

    USGS Publications Warehouse

    Medina, K.D.; Geiger, C.O.

    1984-01-01

    The results of an evaluation of the cost effectiveness of the 1983 stream-gaging program in Kansas are documented. Data uses and funding sources were identified for the 140 complete record streamflow-gaging stations operated in Kansas during 1983 with a budget of $793,780. As a result of the evaluation of the needs and uses of data from the stream-gaging program, it was found that the 140 gaging stations were needed to meet these data requirements. The average standard error of estimation of streamflow records was 20.8 percent, assuming the 1983 budget and operating schedule of 6-week interval visitations and based on 85 of the 140 stations. It was shown that this overall level of accuracy could be improved to 18.9 percent by altering the 1983 schedule of station visitations. A minimum budget of $760 ,000, with a corresponding average error of estimation of 24.9 percent, is required to operate the 1983 program. None of the stations investigated were suitable for the application of alternative methods for simulating discharge records. Improved instrumentation can have a very positive impact on streamflow uncertainties by decreasing lost record. (USGS)

  10. A New Correction Technique for Strain-Gage Measurements Acquired in Transient-Temperature Environments

    NASA Technical Reports Server (NTRS)

    Richards, W. Lance

    1996-01-01

    Significant strain-gage errors may exist in measurements acquired in transient-temperature environments if conventional correction methods are applied. As heating or cooling rates increase, temperature gradients between the strain-gage sensor and substrate surface increase proportionally. These temperature gradients introduce strain-measurement errors that are currently neglected in both conventional strain-correction theory and practice. Therefore, the conventional correction theory has been modified to account for these errors. A new experimental method has been developed to correct strain-gage measurements acquired in environments experiencing significant temperature transients. The new correction technique has been demonstrated through a series of tests in which strain measurements were acquired for temperature-rise rates ranging from 1 to greater than 100 degrees F/sec. Strain-gage data from these tests have been corrected with both the new and conventional methods and then compared with an analysis. Results show that, for temperature-rise rates greater than 10 degrees F/sec, the strain measurements corrected with the conventional technique produced strain errors that deviated from analysis by as much as 45 percent, whereas results corrected with the new technique were in good agreement with analytical results.

  11. Perceptual Differences in Attitudes on Quality Circles.

    ERIC Educational Resources Information Center

    Holcomb, Lynn; Berger, Leonard

    1986-01-01

    A study was conducted to determine any perceptual differences toward quality circles in a chemical plant. It also tried to determine if any perceptual differences that might be found could be related to attitudes toward the circles themselves or the attitudes toward circle members. Length of service was also a factor. (CT)

  12. 49 CFR 179.400-19 - Valves and gages.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400-19 Valves and gages...

  13. Use of Precious Metal-Modifed Nickel-Base Superalloys for Thin Gage Applications (Preprint)

    DTIC Science & Technology

    2011-04-01

    superalloys are being investigated for use in thin gage applications, such as thermal protection systems or heat exchangers, due to their strength and...atomic % total) in place of the platinum and iridium. 15. SUBJECT TERMS thermal protection systems, nickel, superalloy, thermomechanical processing...use in thin gage applications, such as thermal protection systems or heat exchangers, due to their strength and inherent oxidation resistance at

  14. Structure of the bacterial flagellar hook and implication for the molecular universal joint mechanism.

    PubMed

    Samatey, Fadel A; Matsunami, Hideyuki; Imada, Katsumi; Nagashima, Shigehiro; Shaikh, Tanvir R; Thomas, Dennis R; Chen, James Z; Derosier, David J; Kitao, Akio; Namba, Keiichi

    2004-10-28

    The bacterial flagellum is a motile organelle, and the flagellar hook is a short, highly curved tubular structure that connects the flagellar motor to the long filament acting as a helical propeller. The hook is made of about 120 copies of a single protein, FlgE, and its function as a nano-sized universal joint is essential for dynamic and efficient bacterial motility and taxis. It transmits the motor torque to the helical propeller over a wide range of its orientation for swimming and tumbling. Here we report a partial atomic model of the hook obtained by X-ray crystallography of FlgE31, a major proteolytic fragment of FlgE lacking unfolded terminal regions, and by electron cryomicroscopy and three-dimensional helical image reconstruction of the hook. The model reveals the intricate molecular interactions and a plausible switching mechanism for the hook to be flexible in bending but rigid against twisting for its universal joint function.

  15. Quality Circles: Involvement, Problem-Solving, and Recognition.

    ERIC Educational Resources Information Center

    Moretz, H. Lynn

    1983-01-01

    The media production department of Central Piedmont Community College (CPCC) began quality circle meetings in January 1981 after studying the process of quality circles and obtaining the understanding and support of the college administration. A quality circle is a small group of people doing similar work who voluntarily meet on a regular basis to…

  16. The pentag meridian circle

    NASA Astrophysics Data System (ADS)

    Nemiro, A. A.

    The opticomechanical scheme of a pentag meridian circle is presented. The central rotating part of the instrument, made of sitall (cer-vit), is compact and uniform, making it possible to minimize the gravitational and thermal deformations. It is shown that variations of the orientation of the central part do not affect observations because of the use of the pentag. Formulas are presented for determining the collimation error and zero point of the circle using autocollimation readings.

  17. Cost-effectiveness of the stream-gaging program in Maryland, Delaware, and the District of Columbia

    USGS Publications Warehouse

    Carpenter, David H.; James, R.W.; Gillen, D.F.

    1987-01-01

    This report documents the results of a cost-effectiveness study of the stream-gaging program in Maryland, Delaware, and the District of Columbia. Data uses and funding sources were identified for 99 continuously operated stream gages in Maryland , Delaware, and the District of Columbia. The current operation of the program requires a budget of $465,260/year. The average standard error of estimation of streamflow records is 11.8%. It is shown that this overall level of accuracy at the 99 sites could be maintained with a budget of $461,000, if resources were redistributed among the gages. (USGS)

  18. USGS reservoir and lake gage network: Elevation and volumetric contents data, and their uses

    USGS Publications Warehouse

    Kroska, Anita C.

    2014-01-01

    In December of 2013, the U.S. Geological Survey (USGS) marked the 125th anniversary of the installation of its first official water level and streamflow gage, on the Rio Grande at Embudo, New Mexico. The gage was installed because it was recognized that water data were important to expanding irrigation needs. The USGS is a federal agency that provides nationally consistent and unbiased surface-water elevation and streamflow data at more than 10,000 gaging locations in the United States, about 330 of which are lakes and reservoirs (referred to hereafter as lakes) (Figure 1). The job of quantifying water resources, whether lakes, streams, or aquifers, is fundamental to proper water management and conservation of resources.

  19. Crafting the microworld: how Robert Hooke constructed knowledge about small things

    PubMed Central

    Lawson, Ian

    2016-01-01

    This paper investigates the way in which Robert Hooke constructed his microscopical observations. His Micrographia is justifiably famous for its detailed engravings, which communicated Hooke's observations of tiny nature to his readers, but less attention has been paid to how he went about making the observations themselves. In this paper I explore the relationship between the materiality of his instrument and the epistemic images he produced. Behind the pictures lies an array of hidden materials, and the craft knowledge it took to manipulate them. By investigating the often counter-theoretical and conflicting practices of his ingenious microscope use, I demonstrate the way in which Hooke crafted the microworld for his readers, giving insight into how early modern microscopy was understood by its practitioners and audience. PMID:27017680

  20. CRAFTING THE MICROWORLD: HOW ROBERT HOOKE CONSTRUCTED KNOWLEDGE ABOUT SMALL THINGS.

    PubMed

    Lawson, Ian

    2016-03-20

    This paper investigates the way in which Robert Hooke constructed his microscopical observations. His Micrographia is justifiably famous for its detailed engravings, which communicated Hooke's observations of tiny nature to his readers, but less attention has been paid to how he went about making the observations themselves. In this paper I explore the relationship between the materiality of his instrument and the epistemic images he produced. Behind the pictures lies an array of hidden materials, and the craft knowledge it took to manipulate them. By investigating the often counter-theoretical and conflicting practices of his ingenious microscope use, I demonstrate the way in which Hooke crafted the microworld for his readers, giving insight into how early modern microscopy was understood by its practitioners and audience.

  1. Influence of hook position on phototropic and gravitropic curvature by etiolated hypocotyls of Arabidopsis thaliana

    NASA Technical Reports Server (NTRS)

    Khurana, J. P.; Best, T. R.; Poff, K. L.

    1989-01-01

    Phototropic and gravitropic curvature by hypocotyls of Arabidopsis thaliana is minimal when the side of the hook with the cotyledons attached is positioned toward the direction of tropistic curvature, and maximal when that side of the hook is positioned away from the direction of tropistic curvature. Based on these data, it is proposed that the position of the hook with attached cotyledons affects curvature and not stimulus perception. A randomly oriented population of plants exhibited considerable heterogeneity in tropistic curvature. This heterogeneity arises at least in part from the dependence of curvature on the position of the hook.

  2. Influence of hook position on phototropic and gravitropic curvature by etiolated hypocotyls of Arabidopsis thaliana.

    PubMed

    Khurana, J P; Best, T R; Poff, K L

    1989-01-01

    Phototropic and gravitropic curvature by hypocotyls of Arabidopsis thaliana is minimal when the side of the hook with the cotyledons attached is positioned toward the direction of tropistic curvature, and maximal when that side of the hook is positioned away from the direction of tropistic curvature. Based on these data, it is proposed that the position of the hook with attached cotyledons affects curvature and not stimulus perception. A randomly oriented population of plants exhibited considerable heterogeneity in tropistic curvature. This heterogeneity arises at least in part from the dependence of curvature on the position of the hook.

  3. Surgical treatment of acute acromioclavicular joint dislocations: hook plate versus minimally invasive reconstruction.

    PubMed

    Metzlaff, S; Rosslenbroich, S; Forkel, P H; Schliemann, B; Arshad, H; Raschke, M; Petersen, W

    2016-06-01

    This study was performed to compare the clinical results of a minimally invasive technique for acute acromioclavicular (AC) joint dislocation repair with the traditional hook plate fixation. Forty-four patients with an acute (within 2 weeks after trauma) complete AC joint separation (35 male, nine female; median age 36.2 years, range 18-56) underwent surgical repair with either a minimally invasive AC joint repair or a conventional hook plate. Functional outcome was evaluated using the Constant-Murley Score (CMS), the TAFT score and the AC joint instability score (ACJI). Radiographic evaluation was performed with bilateral anterior-posterior (a.p.) stress and Alexander views. All patients were available after a median follow-up of 32 months (range 24-51). There were no significant differences in the mean CMS, Taft score and the ACJI between the two groups. The radiological assessment revealed no significant difference in the coracoclavicular distance. In both groups, a slight loss of reduction was observed. Periarticular ossification was seen in 11 patients of the minimally invasive AC joint repair and eight patients of the hook plate group but this did not affect the final outcome. Hook plates were removed after a median interval of 11.9 weeks (range 10-13). Good clinical results can be achieved with both minimally invasive AC joint repair and hook plate fixation. However, in the hook plate group a second operation is mandatory for plate removal. III.

  4. Hook Region Represented in a Cochlear Model

    NASA Astrophysics Data System (ADS)

    Steele, Charles R.; Kim, Namkeun; Puria, Sunil

    2009-02-01

    The present interest is in discontinuities. Particularly the geometry of the hook region, with the flexible round window nearly parallel with the basilar membrane, is not represented by a standard box model, in which both stapes and round window are placed at the end. A better model represents the round window by a soft membrane in the wall of scala tympani, with the end closed. This complicates the analysis considerably. Features are that the significant compression wave, i.e., the fast wave, is of negligible magnitude in this region, and that significant evanescent waves occur because of the discontinuities at the beginning and end of the simulated round window. The effect of this on both high frequency, with maximum basilar membrane response in the hook region, and lower frequencies are determined.

  5. [Comparison between J-hook and micro-implant anchorage in the treatment of patients with bimaxillary protrusion].

    PubMed

    Chen, Wen-Jing; Li, Qing-Yi; Gong, Ai-Xiu; Hu, Fang; Gu, Yong-Jia

    2008-02-01

    To compare the difference between J-hook and micro-implant anchorage in the treatment of patient with bimaxillary protrusion. Thirty patients with bimaxillary protrusion were divided into two groups (J-hook and micro-implant groups) and treated with MBT appliance. Four first premolars were extracted in all patients. Cephalometric analyses were carried out before and after treatment. In J-hook group and micro-implant group,computerized cephalometric analysis revealed that before treatment U6C-PP was (12.4 +/- 0.2) mm and (12.5 +/- 0.1) mm, respectively,and after treatment U6C-PP was (12.6 +/- 0.1) mm and (12.8 +/- 0.1) mm,respectively. The difference between J-hook group and microimplant group was significant (P < 0.01). The other differences of cephalometric analyses between J-hook group and micro-implant group was not significant. Both J-hook and micro-implant could provide adequate anchorage in the treatment of patients with bimaxillary protrusion.

  6. Physiographic and land cover attributes of the Puget Lowland and the active streamflow gaging network, Puget Sound Basin

    USGS Publications Warehouse

    Konrad, Christopher; Sevier, Maria

    2014-01-01

    Geospatial information for the active streamflow gaging network in the Puget Sound Basin was compiled to support regional monitoring of stormwater effects to small streams. The compilation includes drainage area boundaries and physiographic and land use attributes that affect hydrologic processes. Three types of boundaries were used to tabulate attributes: Puget Sound Watershed Characterization analysis units (AU); the drainage area of active streamflow gages; and the catchments of Regional Stream Monitoring Program (RSMP) sites. The active streamflow gaging network generally includes sites that represent the ranges of attributes for lowland AUs, although there are few sites with low elevations (less than 60 meters), low precipitation (less than 1 meter year), or high stream density (greater than 5 kilometers per square kilometers). The active streamflow gaging network can serve to provide streamflow information in some AUs and RSMP sites, particularly where the streamflow gage measures streamflow generated from a part of the AU or that drains to the RSMP site, and that part of the AU or RSMP site is a significant fraction of the drainage area of the streamgage. The maximum fraction of each AU or RSMP catchment upstream of a streamflow gage and the maximum fraction of any one gaged basin in an AU or RSMP along with corresponding codes are provided in the attribute tables.

  7. Quality Circles: Determination of Significant Factors for Success an a General Model for Implementing a Quality Circle Process.

    DTIC Science & Technology

    1981-06-01

    receive for contributions to quality and productivity /4:Apdx-47. The initiative for the Quality Circle concept came from Dr Kaoru Ishikawa , a...eloquently summarized by the "Father of Quality Circles", Dr Kaoru Ishikawa . He sees that, although Japan started with the worst quality reputation among...Perceptions of Influence, Academy of Management Journal. December 1974, pp 649-bz. 49. Ishikawa , Kaoru . S.C. Circle Activities. Union of Japanese Scientists and

  8. The Application of the Specific Gage Technique and Aerial Photographs in Kaskaskia River Degradation Studies

    NASA Astrophysics Data System (ADS)

    Du, X.

    2008-12-01

    The Kaskaskia River basin contains 136,000 acres of bottomland forest, the largest contiguous tract of bottomland forest remaining in the state of Illinois. Since the 1960's, the Carlyle Lake Dam impoundment and channelization activities have altered the natural hydrologic and ecological equilibrium of the Kaskaskia River. Morphological changes of the river channel have necessitated conservation and restoration efforts to create and maintain the sustainability, diversity, health, and connectivity of the river watershed. This study utilized the specific gage technique and historical aerial photographs to investigate the spatial and temporal changes of the river. Historical daily discharge and daily stage data from the Carlyle (1966 to 2002) and Venedy Station gages (1984 to 2003) were analyzed. Logs of daily discharge data were used to generate annual rating curves. The best fit equations were produced from annual rating regressions. A stage associated with a chosen reference discharge, the minimum available discharge (MAD), was calculated. A stage decreasing/increasing trend was used as a primary indicator of channel bed incision/aggradation. Pseudo specific gage analysis (PSGA) was used to model channel cross sectional geometry changes over time. PSGA applied similar procedures as compared to the specific gage technique. Instead of using the stage variable, PSGA utilized cross sectional width, cross-sectional area, mean velocity and gage height individually. At each gage, the historical change of each cross sectional parameter was plotted against the log of discharge. Ratings of specific stages, specific cross sectional width, specific depth, specific area, and specific velocity associated with the chosen discharge, MAD, were produced. The decreasing/increasing trend of each parameter mentioned above corresponded with changes of channel cross sectional geometries over time. Historical aerial photographs were also used to assess the bankfull channel width changing

  9. Discharge ratings at gaging stations

    USGS Publications Warehouse

    Kennedy, E.J.

    1984-01-01

    A discharge rating is the relation of the discharge at a gaging station to stage and sometimes also to other variables. This chapter of 'Techniques of Water-Resources Investigations' describes the procedures commonly used to develop simple ratings where discharge is related only to stage and the most frequently encountered types of complex ratings where additional factors such as rate of change in stage, water-surface slope, or index velocity are used. Fundamental techniques of logarithmic plotting and the applications of simple storage routing to rating development are demonstrated. Computer applications, especially for handheld programmable calculators, and data handling are stressed.

  10. Performance Outcomes After Hook of Hamate Fractures in Major League Baseball Players.

    PubMed

    Guss, Michael S; Begly, John P; Ramme, Austin J; Taormina, David P; Rettig, Michael E; Capo, John T

    2017-07-17

    Major League Baseball (MLB) players are at risk of hook of hamate fractures. There is a paucity of data assessing the effect of a hook of hamate fracture on MLB players' future athletic performance. To determine if MLB players who sustain hook of hamate fractures demonstrate decreased performance upon return to competition when compared with their performance before injury and that of their control-matched peers. Retrospective Case-Control Design. Retrospective Database Study. 18 MLB players who sustained hook of hamate fractures. Data for 18 MLB players with hook of hamate fractures incurred over 26 seasons (1989 to 2014) were obtained from injury reports, press releases, and player profiles ( www.mlb.com and www.baseballreference.com ). Player age, position, number of years in the league, mechanism of injury and treatment were recorded. Individual season statistics for the two seasons immediately prior to injury and the two seasons after injury for the main performance variable - wins above replacement (WAR) were obtained. Eighteen controls matched by player position, age, and performance statistics were identified. A performance comparison of the cohorts was performed. Post-injury performance compared to pre-injury performance and matched-controls. Mean age at the time of injury was 25.1 years with a mean of 4.4 seasons of MLB experience prior to injury. All injuries were sustained to their nondominant batting hand. All players underwent operative intervention. There was no significant change in WAR or ISO when pre-injury and post-injury performance was compared. When compared with matched-controls, no significant decline in performance in WAR the first season and second season after injury was found. MLB players sustaining hook of hamate fractures can reasonably expect to return to their pre-injury performance levels following operative treatment.

  11. Iterative Strain-Gage Balance Calibration Data Analysis for Extended Independent Variable Sets

    NASA Technical Reports Server (NTRS)

    Ulbrich, Norbert Manfred

    2011-01-01

    A new method was developed that makes it possible to use an extended set of independent calibration variables for an iterative analysis of wind tunnel strain gage balance calibration data. The new method permits the application of the iterative analysis method whenever the total number of balance loads and other independent calibration variables is greater than the total number of measured strain gage outputs. Iteration equations used by the iterative analysis method have the limitation that the number of independent and dependent variables must match. The new method circumvents this limitation. It simply adds a missing dependent variable to the original data set by using an additional independent variable also as an additional dependent variable. Then, the desired solution of the regression analysis problem can be obtained that fits each gage output as a function of both the original and additional independent calibration variables. The final regression coefficients can be converted to data reduction matrix coefficients because the missing dependent variables were added to the data set without changing the regression analysis result for each gage output. Therefore, the new method still supports the application of the two load iteration equation choices that the iterative method traditionally uses for the prediction of balance loads during a wind tunnel test. An example is discussed in the paper that illustrates the application of the new method to a realistic simulation of temperature dependent calibration data set of a six component balance.

  12. A biomechanical analysis of the self-retaining pedicle hook device in posterior spinal fixation

    PubMed Central

    van Laar, Wilbert; Meester, Rinse J.; Smit, Theo H.

    2007-01-01

    Regular hooks lack initial fixation to the spine during spinal deformity surgery. This runs the risk of posterior hook dislodgement during manipulation and correction of the spinal deformity, that may lead to loss of correction, hook migration, and post-operative junctional kyphosis. To prevent hook dislodgement during surgery, a self-retaining pedicle hook device (SPHD) is available that is made up of two counter-positioned hooks forming a monoblock posterior claw device. The initial segmental posterior fixation strength of a SPHD, however, is unknown. A biomechanical pull-out study of posterior segmental spinal fixation in a cadaver vertebral model was designed to investigate the axial pull-out strength for a SPHD, and compared to the pull-out strength of a pedicle screw. Ten porcine lumbar vertebral bodies were instrumented in pairs with two different instrumentation constructs after measuring the bone mineral density of each individual vertebra. The instrumentation constructs were extracted employing a material testing system using axial forces. The maximum pull-out forces were recorded at the time of the construct failure. Failure of the SPHD appeared in rotation and lateral displacement, without fracturing of the posterior structures. The average pull-out strength of the SPHD was 236 N versus 1,047 N in the pedicle screws (P < 0.001). The pull-out strength of the pedicle screws showed greater correlation with the BMC compared to the SPHD (P < 0.005). The SPHD showed to provide a significant inferior segmental fixation to the posterior spine in comparison to pedicle screw fixation. Despite the beneficial characteristics of the monoblock claw construct in a SPHD, that decreases the risk of posterior hook dislodgement during surgery compared to regular hooks, the SPHD does not improve the pull-out strength in such a way that it may provide a biomechanically solid alternative to pedicle screw fixation in the posterior spine. PMID:17203270

  13. Thin layer asphaltic concrete density measuring using nuclear gages.

    DOT National Transportation Integrated Search

    1989-03-01

    A Troxler 4640 thin layer nuclear gage was evaluated under field conditions to determine if it would provide improved accuracy of density measurements on asphalt overlays of 1-3/4 and 2 inches in thickness. Statistical analysis shows slightly improve...

  14. The hooked element in the pes of turtles (Testudines): a global approach to exploring primary and secondary homology

    PubMed Central

    Joyce, Walter G; Werneburg, Ingmar; Lyson, Tyler R

    2013-01-01

    The hooked element in the pes of turtles was historically identified by most palaeontologists and embryologists as a modified fifth metatarsal, and often used as evidence to unite turtles with other reptiles with a hooked element. Some recent embryological studies, however, revealed that this element might represent an enlarged fifth distal tarsal. We herein provide extensive new myological and developmental observations on the hooked element of turtles, and re-evaluate its primary and secondary homology using all available lines of evidence. Digital count and timing of development are uninformative. However, extensive myological, embryological and topological data are consistent with the hypothesis that the hooked element of turtles represents a fusion of the fifth distal tarsal with the fifth metatarsal, but that the fifth distal tarsal dominates the hooked element in pleurodiran turtles, whereas the fifth metatarsal dominates the hooked element of cryptodiran turtles. The term ‘ansulate bone’ is proposed to refer to hooked elements that result from the fusion of these two bones. The available phylogenetic and fossil data are currently insufficient to clarify the secondary homology of hooked elements within Reptilia. PMID:24102560

  15. What Works: Study Circles in the Real World. Best Practices for Producing Community-Wide Study Circles.

    ERIC Educational Resources Information Center

    Mengual, Gloria

    This document, which is based on information gathered during a 1998 study of how study circle programs contribute to community problem solving, presents best practices for producing community-wide study circles. The best practices are illustrated through stories that are grouped into five sections on the following themes: (1) creating a…

  16. Gap compression/extension mechanism of bacterial flagellar hook as the molecular universal joint.

    PubMed

    Furuta, Tadaomi; Samatey, Fadel A; Matsunami, Hideyuki; Imada, Katsumi; Namba, Keiichi; Kitao, Akio

    2007-03-01

    Bacterial flagellar hook acts as a molecular universal joint, transmitting torque produced by the flagellar basal body, a rotary motor, to the flagellar filament. The hook forms polymorphic supercoil structures and can be considered as an assembly of 11 circularly arranged protofilaments. We investigated the molecular mechanism of the universal joint function of the hook by a approximately two-million-atom molecular dynamics simulation. On the inner side of the supercoil, protein subunits are highly packed along the protofilament and no gaps remain for further compression, whereas subunits are slightly separated and are hydrogen bonded through one layer of water molecules on the outer side. As for the intersubunit interactions between protofilaments, subunits are packed along the 6-start helix in a left-handed supercoil whereas they are highly packed along the 5-start helix in a right-handed supercoil. We conclude that the supercoiled structures of the hook in the left- and right-handed forms make maximal use of the gaps between subunits, which we call "gap compression/extension mechanism". Mutual sliding of subunits at the subunit interface accompanying rearrangements of intersubunit hydrogen bonds is interpreted as a mechanism to allow continuous structural change of the hook during flagellar rotation at low energy cost.

  17. Talk about "hooking up": the influence of college student social networks on nonrelationship sex.

    PubMed

    Holman, Amanda; Sillars, Alan

    2012-01-01

    This research considers how communication within college student social networks may encourage high-risk sexual relationships. Students (n = 274) described sexual scripts for hooking up and reported on peer communication, sexual behavior, and sexual attitudes. Students described varied hookup scripts, expressed ambivalent attitudes, and reported moderate participation in hookups overall. However, the most common hookup script, suggesting high-risk sexual activity (i.e., unplanned, inebriated sex), was featured in most accounts of students who themselves participated in hookups. Students overestimated how often others were hooking up, and these estimates were especially inflated by students who frequently talked about hooking up with friends. Among students with strong ties to peers, frequent peer communication about sex predicted participation in hookups and favorable attitudes about hooking up. Peer approval also predicted hookup behavior and attitudes.

  18. Fostering Classroom Communities through Circling with Teacher Candidates

    ERIC Educational Resources Information Center

    Bouchard, Karen L.; Hollweck, Trista; Smith, J. David

    2016-01-01

    Classroom circles have been recognized as a valuable pedagogical approach to develop students' social-emotional learning and to establish a sense of community within a classroom. Until recently, there has been little consideration that teachers, themselves, may benefit from circling experiences. To garner a deeper understanding of circling for…

  19. GENERATING FRACTAL PATTERNS BY USING p-CIRCLE INVERSION

    NASA Astrophysics Data System (ADS)

    Ramírez, José L.; Rubiano, Gustavo N.; Zlobec, Borut Jurčič

    2015-10-01

    In this paper, we introduce the p-circle inversion which generalizes the classical inversion with respect to a circle (p = 2) and the taxicab inversion (p = 1). We study some basic properties and we also show the inversive images of some basic curves. We apply this new transformation to well-known fractals such as Sierpinski triangle, Koch curve, dragon curve, Fibonacci fractal, among others. Then we obtain new fractal patterns. Moreover, we generalize the method called circle inversion fractal be means of the p-circle inversion.

  20. Evaluation of GE-167 Silicone Rubber (RTV) For Possible Service As A Moisture-Barrier For Certain Strain Gage Applications

    NASA Technical Reports Server (NTRS)

    Hare, David A.; Moore, Thomas C., Sr.

    2000-01-01

    The Langley Research Center uses strain gages in a wide variety of demanding test environments. Strain gage installations, depending on the testing scenario, may see high temperatures, cryogenic temperature, moisture accumulation, mechanical abuse, or any combination of these conditions. At Langley, there is often a need to provide protection for strain gages against moisture and mechanical abuse, especially when large-scale, harsh environment testing is to be encountered. This technical memorandum discusses the evaluation of a room temperature curing silicone rubber sealant manufactured by the General Electric Company for consideration as a moisture-barrier for certain strain gage installations.

  1. The M-T Hook Structure Is Critical for Design of HIV-1 Fusion Inhibitors*

    PubMed Central

    Chong, Huihui; Yao, Xue; Sun, Jianping; Qiu, Zonglin; Zhang, Meng; Waltersperger, Sandro; Wang, Meitian; Cui, Sheng; He, Yuxian

    2012-01-01

    CP621-652 is a potent HIV-1 fusion inhibitor peptide derived from the C-terminal heptad repeat of gp41. We recently identified that its N-terminal residues Met-626 and Thr-627 adopt a unique hook-like structure (termed M-T hook) thus stabilizing the interaction of the inhibitor with the deep pocket on the N-terminal heptad repeat. In this study, we further demonstrated that the M-T hook structure is a key determinant of CP621-652 in terms of its thermostability and anti-HIV activity. To directly define the structure and function of the M-T hook, we generated the peptide MT-C34 by incorporating Met-626 and Thr-627 into the N terminus of the C-terminal heptad repeat-derived peptide C34. The high resolution crystal structure (1.9 Å) of MT-C34 complexed by an N-terminal heptad repeat-derived peptide reveals that the M-T hook conformation is well preserved at the N-terminal extreme of the inhibitor. Strikingly, addition of two hook residues could dramatically enhance the binding affinity and thermostability of 6-helix bundle core. Compared with C34, MT-C34 exhibited significantly increased activity to inhibit HIV-1 envelope-mediated cell fusion (6.6-fold), virus entry (4.5-fold), and replication (6-fold). Mechanistically, MT-C34 had a 10.5-fold higher increase than C34 in blocking 6-helix bundle formation. We further showed that MT-C34 possessed higher potency against T20 (Enfuvirtide, Fuzeon)-resistant HIV-1 variants. Therefore, this study provides convincing data for our proposed concept that the M-T hook structure is critical for designing HIV-1 fusion inhibitors. PMID:22879603

  2. Application of Rubber Band with Hooks on Both Ends for Vagus Nerve Stimulator Implantation.

    PubMed

    Hosoyama, Hiroshi; Hanaya, Ryosuke; Otsubo, Toshiaki; Sato, Masanori; Kashida, Yumi; Sugata, Sei; Katagiri, Masaya; Iida, Koji; Arita, Kazunori

    2018-03-01

    Vagus nerve stimulation (VNS) is a valuable therapeutic option for many types of drug-resistant epilepsy. Muscle hooks and carotid endarterectomy rings have been used for cervical delamination preceding the implantation of stimulation electrodes. The attachment on both sides of a rubber band of Kamiyama-style hanging needles, as are used for scalp and dural retraction during craniotomy, yields a useful tool for VNS implantation. Here we report our experience with this method. We present our method using a rubber band plus hooks and a review of 21 consecutive patients who underwent VNS implantation using our rubber band-plus-hooks method. None of the 21 patients experienced intraoperative or perioperative complications. Hooks placed in connective tissue around the common carotid artery and jugular vein raised the vagus nerve by elevating the carotid sheath. A single surgeon was able to perform all cervical manipulations under a surgical microscope. The average operation time in this series of 21 patients was 137 minutes. The use of hooks attached to both sides of a rubber band rendered VNS implantation safer by lifting the vagus nerve and standardizing the procedure. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. The "Us" in Discuss: Grouping in Literature Circles

    ERIC Educational Resources Information Center

    Batchelor, Katherine

    2012-01-01

    This article describes one middle school teacher's use of literature circles using heterogeneous grouping. It begins with a brief rationale for using literature circles in the language arts classroom. Next, it describes techniques to form literature circles. Then, it shares how to build and establish a supportive environment within each group. It…

  4. The experience of meaning in circle dance

    PubMed Central

    Borges da Costa, Ana L.; Cox, Diane L.

    2016-01-01

    ABSTRACT Circle dance, which derives from the tradition of folk dances, is practised worldwide. This article explores the meanings participants attribute to it. In-depth interviews with 39 participants, teachers and coordinators of teacher training programmes from the circle dance network in the United Kingdom were undertaken. Applying a constructivist grounded theory approach, major categories, representing respectively the experiences of circle dance participants, teachers and coordinators, were developed. This article specifically focuses on the first major category, termed “I can't imagine life without it”, which relates to the experience of 22 dancers. From an occupational perspective, the study reveals how participants realise a sense of meaning and satisfaction through engagement in circle dance and the potential contribution of this occupation to well-being. PMID:27366111

  5. Flood of April 2007 and Flood-Frequency Estimates at Streamflow-Gaging Stations in Western Connecticut

    USGS Publications Warehouse

    Ahearn, Elizabeth A.

    2009-01-01

    April 2007 peak discharges for streamflow-gaging stations with records extending back to 1955 were the second highest peak discharges on record; the 1955 annual peak discharges are the highest peak discharges in the station records. In the Housatonic and South Central Coast Basins, the April 2007 peak discharges for streamflow-gaging stations with records extending back to 1930 or earlier ranked between the fourth and eighth highest discharges on record, with the 1936, 1938, and 1955 floods as the largest floods in the station records. The peak discharges for the April 2007 flood have exceedance probabilities ranging between 0.10 to 0.02 (a 10- to 2-percent chance of being exceeded in a given year, respectively) with the majority (80 percent) of the stations having exceedance probabilities between 0.10 to 0.04. At three stations - Norwalk River at South Wilton, Pootatuck River at Sandy Hook, and Still River at Robertsville - the April 2007 peak discharges have an exceedance probability of 0.02. Flood-frequency estimates made after the April 2007 flood were compared to flood-frequency estimates used to derive the water-surface profiles (also called flood profiles) in FEMA Flood Insurance Studies developed for communities. In general, the comparison indicated that at the 0.10 exceedance probability (a 10-percent change of being exceeded in a given year), the discharges from the current (2007) flood-frequency analysis are larger than the discharges in the FEMA Flood Insurance Studies, with a median change of about +10 percent. In contrast, at the 0.01 exceedance probability (a 1-percent change of being exceeded in a year), the discharges from the current flood-frequency analysis are smaller than the discharges in the FEMA Flood Insurance Studies, with a median change of about -13 percent. Several stations had more than + 25 percent change in discharges at the 0.10 exceedance probability and are in the following communities: Winchester (Still River at Robertsv

  6. Wire-Strain-Gage Hinge-Moment Indicators for Use in Tests of Airplane Models

    NASA Technical Reports Server (NTRS)

    Edwards, Howard B.

    1944-01-01

    The design and construction of various forms of strain-gage spring units and hinge-moment assemblies are discussed with particular reference to wind-tunnel test, although the indicators may be used equally well in flight tests. Strain-gage specifications are given, and the techniques of their application and use are described briefly. Testing, calibration and operation of hinge-moment indicators are discussed and precautions necessary for successful operation are stressed. Difficulties that may be encountered are summarized along with the possible causes.

  7. Ingestion and ejection of hooks: effects on long-term health and mortality of angler-caught yellowfin bream Acanthopagrus australis.

    PubMed

    Broadhurst, Matt K; Butcher, Paul A; Brand, Craig P; Porter, Mark

    2007-02-08

    Ninety juvenile yellowfin bream Acanthopagrus australis were angled from holding tanks, allowed to ingest nickel-plated, carbon-steel J-hooks and released (with their lines cut) into individual experimental tanks during 2 experiments in order to assess their (1) long-term (up to 105 d) health, mortality and rate of hook ejection and (2) short- and medium-term (< 42 d) temporal changes in health during hook ingestion. Equal numbers of control fish were scooped from holding tanks and similarly monitored in experimental tanks. Of 20 hook-ingested fish released during Expt 1, 3 died within 8 d, providing a non-significant mortality of 15%. Between Day 6 and Day 56 post-release, 13 of the surviving individuals ejected their hooks, which were typically oxidized to about 94% of their original weight and often broken into 2 pieces. At Day 105, there were no significant differences between the 20 control and 17 hook-ingested/-ejected fish in terms of their ability to digest and assimilate food (measured as changes in apparent digestibility coefficients), stress (measured as concentrations of plasma cortisol and glucose) or of morphological parameters that included weight (Wt) and maximum height (MH), maximum width (MW) and maximum girth (MG). During Expt 2, 3 individuals that still contained ingested hooks and 3 controls were sampled on each of 9 occasions between Day 3 and Day 42 post-release. All fish were sampled for blood cortisol and glucose and were then euthanized before being weighed and measured for total length (TL), MH, MW and MG. Hook-ingested individuals were also X-rayed to determine the position and orientation of hooks. There were no significant differences in plasma glucose between hook-ingested and control fish. Irrespective of the treatment of fish, concentrations of cortisol were elevated on some sampling occasions, indicating variable, acute stress. The MH and MG of fish were not significantly different between groups. Significant differences were

  8. Comparison of NEXRAD multisensor precipitation estimates to rain gage observations in and near DuPage County, Illinois, 2002–12

    USGS Publications Warehouse

    Spies, Ryan R.; Over, Thomas M.; Ortel, Terry W.

    2018-05-21

    In this report, precipitation data from 2002 to 2012 from the hourly gridded Next-Generation Radar (NEXRAD)-based Multisensor Precipitation Estimate (MPE) precipitation product are compared to precipitation data from two rain gage networks—an automated tipping bucket network of 25 rain gages operated by the U.S. Geological Survey (USGS) and 51 rain gages from the volunteer-operated Community Collaborative Rain, Hail, and Snow (CoCoRaHS) network—in and near DuPage County, Illinois, at a daily time step to test for long-term differences in space, time, and distribution. The NEXRAD–MPE data that are used are from the fifty 2.5-mile grid cells overlying the rain gages from the other networks. Because of the challenges of measuring of frozen precipitation, the analysis period is separated between days with or without the chance of freezing conditions. The NEXRAD–MPE and tipping-bucket rain gage precipitation data are adjusted to account for undercatch by multiplying by a previously determined factor of 1.14. Under nonfreezing conditions, the three precipitation datasets are broadly similar in cumulative depth and distribution of daily values when the data are combined spatially across the networks. However, the NEXRAD–MPE data indicate a significant trend relative to both rain gage networks as a function of distance from the NEXRAD radar just south of the study area. During freezing conditions, of the USGS network rain gages only the heated gages were considered, and these gages indicate substantial mean undercatch of 50 and 61 percent compared to the NEXRAD–MPE and the CoCoRaHS gages, respectively. The heated USGS rain gages also indicate substantially lower quantile values during freezing conditions, except during the most extreme (highest) events. Because NEXRAD precipitation products are continually evolving, the report concludes with a discussion of recent changes in those products and their potential for improved precipitation estimation. An appendix

  9. Evaluation in vitro of the tensile strength of crimpable hooks used for stabilization in orthognathic surgery.

    PubMed

    Andrade Gomes, Nascimento Leonard Euller; Melo, Pithon Matheus; Lacerda, Santos Rogério; D'Albuquerque, Medeiros Paulo Jose

    2012-03-01

    The aim of this study was to evaluate the tensile strength of crimpable hooks used for arch stabilization in orthognatic surgery. Ninety stainless steel wire (0.019" × 0.026") segments, each measuring 6 cm long, were used and attached to crimpable hooks of different commercial brands. Six groups were formed (n = 10) denominated as follows: control, in which the wire segments were perpendicularly welded by spot welding machine; and the hooks groups M (Morelli), MS (Morelli with weld), TP (TP Ortho), TPS (TP with weld), TPTg (TP-tungsten), TPTgS (TP-tungsten with weld), AO (American Orthodontics), and AOS (American Orthodontics with weld). The test specimen topography was evaluated by scanning electron microscopy before and after the tensile strength tests. After obtaining the results, the analysis of variance and Kruskal-Wallis multiple-comparison tests were applied. Compared with the control group, the AOS ball hooks and those from TPS required a greater amount of force to be displaced along the rectangular arch. The hooks in group M were significantly easier to displace, followed by those from AO. The best ball hooks for clinical application are those from AOS and TPS. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Prevalence of Ingested Fish Hooks in Freshwater Turtles from Five Rivers in the Southeastern United States

    PubMed Central

    Steen, David A.; Hopkins, Brittney C.; Van Dyke, James U.; Hopkins, William A.

    2014-01-01

    Freshwater turtles may ingest baited fish hooks because many are opportunistic scavengers. Although the ingestion of fish hooks is known to be a source of mortality in multiple vertebrate groups, the prevalence of hook ingestion by freshwater turtles has not been well studied. We trapped turtles from five rivers in the southeastern United States and used radiographs to examine over 600 individuals of four species. Depending on the species, sex, and age class, 0–33% of turtles contained ingested fish hooks. For some species, larger turtles were more likely to contain a fish hook than smaller individuals. Freshwater turtle demography suggests that even small increases in adult mortality may lead to population declines. If our study areas are representative of other aquatic systems that receive fishing pressure, this work likely identifies a potential conflict between a widespread, common recreational activity (i.e., fishing) and an imperiled taxonomic group. PMID:24621919

  11. Analysis of D’Alembert Unfolding Technique for Hopkinson Bar Gage Records

    DTIC Science & Technology

    1992-06-01

    MIPH No. 90652 The lfnorcqs in ttn:s ýprrt 7-n Deoarirne~nt o ý te Ip~ A~ r chn ;r vF’ pl J<P D lne! I~rozgj~lj~ The ccnitpnts of trhi-, repoit w;’ rf...0 -I0u’ -4 S.2 ,i i I II III i 00 0 04 ( d )3dflSS8dd 4 pulse is applied. This pressure pulse propagates down...GAGE WAVE TRAVEL WHEN STRESS WAVE IS AT WAV TAVE POSITIONS A, B, C, AND D Figure 2. Description of wave propagation and strain gage output in a bar

  12. Casual hook up sex during the first year of college: Prospective associations with attitudes about sex and love relationships.

    PubMed

    Katz, Jennifer; Schneider, Monica E

    2013-11-01

    This study examined bidirectional relationships among emerging adults' involvement in casual hook up sex and attitudes about sex and love relationships. At the start and end of their first year in college, undergraduates (N = 163) responded to measures of sexual behavior, sexual attitudes, and attitudes about love relationships. In cross-sectional analyses, attitudes about sex and love both were associated with involvement in casual hook up sex. In prospective analyses, initial attitudes about sexual instrumentality uniquely predicted involvement in later hook up sex, even after controlling for past hook up sex. Furthermore, involvement in hook up sex during the first year of college predicted greater sexual permissiveness and comfort with casual genital contact, even after controlling for initial sexual attitudes and hook up behaviors. None of the associations between attitudes and behavior were qualified by gender. Experiences of causal hook up sex appear to have implications primarily for emerging adults' attitudes about sexual interactions rather than their attitudes about love relationships.

  13. High temperature strain gages

    NASA Technical Reports Server (NTRS)

    Gregory, Otto J. (Inventor); You, Tao (Inventor)

    2011-01-01

    A ceramic strain gage based on reactively sputtered indium-tin-oxide (ITO) thin films is used to monitor the structural integrity of components employed in aerospace propulsion systems operating at temperatures in excess of 1500.degree. C. A scanning electron microscopy (SEM) of the thick ITO sensors reveals a partially sintered microstructure comprising a contiguous network of submicron ITO particles with well defined necks and isolated nanoporosity. Densification of the ITO particles was retarded during high temperature exposure with nitrogen thus stabilizing the nanoporosity. ITO strain sensors were prepared by reactive sputtering in various nitrogen/oxygen/argon partial pressures to incorporate more nitrogen into the films. Under these conditions, sintering and densification of the ITO particles containing these nitrogen rich grain boundaries was retarded and a contiguous network of nano-sized ITO particles was established.

  14. The clavicle hook plate for Neer type II lateral clavicle fractures.

    PubMed

    Renger, R J; Roukema, G R; Reurings, J C; Raams, P M; Font, J; Verleisdonk, E J M M

    2009-09-01

    To evaluate functional and radiologic outcome in patients with a Neer type II lateral clavicle fracture treated with the clavicle hook plate. Multicenter retrospective study. Five level I and II trauma centers. Forty-four patients, average age 38.4 years (18-66 years), with a Neer type II lateral clavicle fracture treated with the clavicle hook plate between January 1, 2003, and December 31, 2006. Open reduction and internal fixation with the clavicle hook plate. Removal of all 44 implants after consolidation at a mean of 8.4 months (2-33 months) postoperatively. At an average follow-up of 27.4 months (13-48 months), functional outcome was assessed with the Constant-Murley scoring system. Radiographs were taken to evaluate consolidation and to determine the distance between the coracoid process and the clavicle. The average Constant score was 92.4 (74-100). The average distance between the coracoid process and the clavicle was 9.8 mm (7.3-14.8 mm) compared with 9.4 mm (6.9-14.3 mm) on the contralateral nonoperative side. We observed 1 dislocation of an implant (2.2%), 2 cases of pseudarthrosis (4.5%), 2 superficial wound infections (4.5%), 2 patients with hypertrophic scar tissue (4.5%), and 3 times an acromial osteolysis (6.8%). Thirty patients (68%) reported discomfort due to the implant. These implant-related complaints and the acromial osteolysis disappeared after removal of the hook plate. With all the patients, direct functional aftercare was possible. The clavicle hook plate is a suitable implant for Neer type II clavicle fractures. The advantage of this osteosynthesis is the possibility of immediate functional aftercare. We observed a high percentage of discomfort due to the implant; therefore, we advise to remove the implant as soon as consolidation has taken place.

  15. Developing Soft Skills Using "Literature Circles"

    ERIC Educational Resources Information Center

    Azmi, Mohd Nazri Bin Latiff

    2013-01-01

    This study investigates the impact of the implementation of "Literature Circles" in an Active Learning classroom in relations to developing soft skills among university students. The use of Literature Circles is a well-known strategy in teaching the students to be more creative, independent, and think out of the box. A group of…

  16. 42 CFR 84.82 - Gas pressure gages; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Gas pressure gages; minimum requirements. 84.82 Section 84.82 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  17. 42 CFR 84.82 - Gas pressure gages; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Gas pressure gages; minimum requirements. 84.82 Section 84.82 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  18. 42 CFR 84.82 - Gas pressure gages; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas pressure gages; minimum requirements. 84.82 Section 84.82 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  19. 42 CFR 84.82 - Gas pressure gages; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Gas pressure gages; minimum requirements. 84.82 Section 84.82 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  20. 42 CFR 84.82 - Gas pressure gages; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Gas pressure gages; minimum requirements. 84.82 Section 84.82 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  1. Fish hook injury: removal by ''push through and cut off'' technique: a case report and brief literature review.

    PubMed

    Ahmad Khan, Hayat; Kamal, Younis; Lone, Ansar Ul Haq

    2014-04-01

    Fishing is a leisure activity for some people around the world. Accidently the fish hook can get hooked in the hand. If the hook is barbed, removal becomes difficult. We report a case of such a injury in the hand and discuss the technique for its removal with a brief review of the literature. A thirty-two year old male accidently suffered a fishhook injury to his hand. He came to the orthopaedic ward two hours after the incident with pain; the fish hook was hanging from the hand. Unsuccessful attempts to remove it were made by his relatives. A push-through and cut-off technique was used for removal of barbed hook. Barbed hooks are to be removed atraumatically with controlled incision over properly anaesthetised skin. Proper wound management and prophylactic antibiotics suitable for treatment of Aeromonas species should be initiated to prevent complications.

  2. Design of a Multifrequency Reed-Type Shock Gage With an Inertia-Operated Trigger

    DTIC Science & Technology

    1949-05-01

    SSBärl=^isä&^^^^^^^Z^^^mSSSn^ •RAPE£LHQLDIUG PLATE.- SEED CDiÜMM_SKAE PÄPEP"C*£I:AMP^-, / SHAFTS SPACEß COMPEESSION OI?WE SPEIW PAPEB HOIOEE LATCH ...which wedges it against a sta- tionary plate located opposite the ratchet. Operation of Gage After the gage is mounted on the structure to be...clamping nut, waxed paper is inserted, and the paper holder is pulled back 2 in. by hand until it is engaged by a paper-holder latch provided at the

  3. Instrumentation, methods of flood-data collection and transmission, and evaluation of streamflow-gaging network in Indiana

    USGS Publications Warehouse

    Glatfelter, D.R.; Butch, G.K.

    1994-01-01

    The study results indicate that installation of streamflow-gaging stations at 15 new sites would improve collection of flood data. Instrumenting the 15 new sites plus 26 existing streamflow-gaging stations with telemetry, preferably data-collection platforms with satellite transmitters, would improve transmission of data to users of the information.

  4. Electrical Properties of Materials for Elevated Temperature Resistance Strain Gage Application. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Lei, Jih-Fen

    1987-01-01

    The objective was to study the electrical resistances of materials that are potentially useful as resistance strain gages at 1000 C. Transition metal carbides and nitrides, boron carbide and silicon carbide were selected for the experimental phase of this research. Due to their low temperature coefficient of resistance and good stability, TiC, ZrC, B sub 4 C and beta-SiC are suggested as good candidates for high temperature resistance strain gage applications.

  5. A Spring Playscape Project: Building a Tree Circle

    ERIC Educational Resources Information Center

    Keeler, Rusty

    2009-01-01

    The Tree Circle is a green gathering area for children made by planting trees in a circle. For children, the Tree Circle becomes a magical place for dramatic play, quiet retreat, or lively nature exploration. For teachers and parents it becomes a shady grove for snacks and stories. The trees create a sweet spot that changes during the seasons and…

  6. 50. Stream gaging station in steelpipe well and shelter, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. Stream gaging station in steel-pipe well and shelter, looking west. Photo by Robin Lee Tedder, Puget Power, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  7. 26. Mechanical float gages used to monitor level of water ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. Mechanical float gages used to monitor level of water in the filtration bed reservoir. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  8. Abnormally low hCG in a complete hydatidiform molar pregnancy: The hook effect.

    PubMed

    Nodler, James L; Kim, Kenneth H; Alvarez, Ronald D

    2011-01-01

    ► The hook effect occurs with extremely high levels of hCG, saturating detection antibodies, leading to falsely low laboratory results. ► In the literature, descriptions of the hook effect are rare in cases of gestational trophoblastic diseases. ► If unrecognized, this can lead to delayed therapy or mismanagement of care.

  9. Morphological and histochemical demonstration of hooks in the rostellar region of Cysticercus bovis.

    PubMed

    Zdárská, Z

    1976-01-01

    Hooklets and early developmental stages of hooks were discovered in the tegument among the microtriches in the rostellar region of 83- and 108-day-old Cysticercus bovis. The cortical layer of hooks consists of proteins with tyrosine and SS groups. The rostellar sac and bulb are distinctly developed in the parenchyma of the rostellar region.

  10. High Temperature - Thin Film Strain Gages Based on Alloys of Indium Tin Oxide

    NASA Technical Reports Server (NTRS)

    Gregory, Otto J.; Cooke, James D.; Bienkiewicz, Joseph M.

    1998-01-01

    A stable, high temperature strain gage based on reactively sputtered indium tin oxide (ITO) was demonstrated at temperatures up to 1050 C. These strain sensors exhibited relatively large, negative gage factors at room temperature and their piezoresistive response was both linear and reproducible when strained up to 700 micro-in/in. When cycled between compression and tension, these sensors also showed very little hysteresis, indicating excellent mechanical stability. Thin film strain gages based on selected ITO alloys withstood more than 50,000 strain cycles of +/- 500 micro-in/in during 180 hours of testing in air at 1000 C, with minimal drift at temperature. Drift rates as low as 0.0009%/hr at 1000 C were observed for ITO films that were annealed in nitrogen at 700 C prior to strain testing. These results compare favorably with state of the art 10 micro-m thick PdCr films deposited by NASA, where drift rates of 0.047%/hr at 1050 C were observed. Nitrogen annealing not only produced the lowest drift rates to date, but also produce the largest dynamic gage factors (G = 23.5). These wide bandgap, semiconductor strain sensors also exhibited moderately low temperature coefficients of resistance (TCR) at temperatures up to 1100 C, when tested in a nitrogen ambient. A TCR of +230 ppm/C over the temperature range 200 C < T < 500 C and a TCR of -469 ppm/C over the temperature range 600 C < T < 1100 C was observed for the films tested in nitrogen. However, the resistivity behavior changed considerably when the same films were tested in oxygen ambients. A TCR of -1560 ppm/C was obtained over the temperature range of 200 C < T < 1100 C. When similar films were protected with an overcoat or when ITO films were prepared with higher oxygen contents in the plasma, two distinct TCR's were observed. At T < 800 C, a linear TCR of -210 ppm/C was observed and at T > 800 C, a linear TCR of -2170 DDm/C was observed. The combination of a moderately low TCR and a relatively large gage

  11. [Treatment of sternoclavicular joint dislocation with sternoclavicular hook plate fixation].

    PubMed

    Liu, Pan; Yuan, Jia-bin; Liu, Zhong-qian; Lu, Bing; Wang, Yue

    2015-08-01

    To evaluate the technique and therapeutic effect of sternoclavicular hook plate fixation in treating sternoclavicular joint (SCJ) dislocation. From January 2010 to March 2014,6 patients with SCJ dislocation were treated with sternoclavicular hook plate fixation in our hospital. Among the 6 patients, 5 patients were male and 1 patient was female, and the average age was 34 years, ranging from 26 to 48 years. The course of the disease ranged from 3 to 20 days. All the SCJ dislocations were caused by external injury and accompanied with the symptoms of swelling pain and obvious shoulder joint activity restricted in affected side. All SCJ dislocations were anterior dislocation by the diagnosis of X-ray and CT scan. The postoperative curative effect was evaluated according to Rockwood score. All the patients' operative incision were healed well and in good appearance. X-ray showed that the dislocated SCJ was well reduced and the plate was on right position. All the 6 patients were followed up for 4 to 18 months, with an average of 12 months. The results were evaluated according to Rockwood score, 4 got excellent results, 1 good and 1 fair. No fixation loosening, redislocation or side injury such as vessel, nerve or pleura injury were found. With sternoclavicular hook plate fixation, SCJ dislocation could be reduced while keeping its amphiarthrodial function and the completeness of the cartilage surface. Sternoclavicular hook plate fixation has advantages of safety and stabilization in fixation, and patients can begin function exercises earlier.

  12. 46 CFR 98.25-45 - Liquid level gaging device.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Liquid level gaging device. 98.25-45 Section 98.25-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS SPECIAL CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Anhydrous Ammonia in Bulk...

  13. 46 CFR 98.25-45 - Liquid level gaging device.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Liquid level gaging device. 98.25-45 Section 98.25-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS SPECIAL CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Anhydrous Ammonia in Bulk...

  14. 46 CFR 98.25-45 - Liquid level gaging device.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Liquid level gaging device. 98.25-45 Section 98.25-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS SPECIAL CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Anhydrous Ammonia in Bulk...

  15. 46 CFR 98.25-45 - Liquid level gaging device.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Liquid level gaging device. 98.25-45 Section 98.25-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS SPECIAL CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Anhydrous Ammonia in Bulk...

  16. 46 CFR 98.25-45 - Liquid level gaging device.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Liquid level gaging device. 98.25-45 Section 98.25-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS SPECIAL CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Anhydrous Ammonia in Bulk...

  17. 49. View of unlined canal near inline stream gaging station, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    49. View of unlined canal near in-line stream gaging station, looking west. Photo by Robin Lee Tedder, Puget Power, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  18. 49 CFR 213.110 - Gage restraint measurement systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... applied force from 0 to 4,000 pounds; and (ii) The gage of the track under 4,000 pounds of applied force... requirements specified in §§ 213.109 and 213.127. (5) If the PTLF becomes non-functional or is missing, the... vertical loading of the track is necessary for contact with the lateral rail restraint components, a PTLF...

  19. 49 CFR 213.110 - Gage restraint measurement systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... applied force from 0 to 4,000 pounds; and (ii) The gage of the track under 4,000 pounds of applied force... requirements specified in §§ 213.109 and 213.127. (5) If the PTLF becomes non-functional or is missing, the... vertical loading of the track is necessary for contact with the lateral rail restraint components, a PTLF...

  20. 49 CFR 213.110 - Gage restraint measurement systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... applied force from 0 to 4,000 pounds; and (ii) The gage of the track under 4,000 pounds of applied force... requirements specified in §§ 213.109 and 213.127. (5) If the PTLF becomes non-functional or is missing, the... vertical loading of the track is necessary for contact with the lateral rail restraint components, a PTLF...

  1. Unit Circles and Inverse Trigonometric Functions

    ERIC Educational Resources Information Center

    Barrera, Azael

    2014-01-01

    Historical accounts of trigonometry refer to the works of many Indian and Arab astronomers on the origin of the trigonometric functions as we know them now, in particular Abu al-Wafa (ca. 980 CE), who determined and named all known trigonometric functions from segments constructed on a regular circle and later on a unit circle (Moussa 2011;…

  2. Made-in-USA Quality Circles Become People-Building Tool.

    ERIC Educational Resources Information Center

    Cohen, Larry

    1983-01-01

    Discusses the use of quality circles as a human resources development tool in Middlesex Community College's Career-Oriented Peer Services tutoring center. Delineates rules for circle participants and follows the activities of two circles comprised of business-oriented and engineering-oriented students. (DMM)

  3. On the reliability of hook echoes as tornado indicators

    NASA Technical Reports Server (NTRS)

    Forbes, G. S.

    1981-01-01

    A study of radar echoes associated with the tornadoes of the 3 April 1974 outbreak was performed to evaluate the usefulness of echo shape as an indicator of tornadic thunderstorms. The hook shape was usually successful in characterizing an echo as tornadic, with a false alarm rate of 16%. Because hook echoes were relatively rare, however, a less restrictive shape called distinctive was more successful at detecting tornadic thunderstorms, identifying 65% of the tornadic echoes. An echo had a distinctive shape if it possessed a marked appendage on its right rear flank or was in the shape of a spiral, comma or line echo wave pattern (LEWP). Characteristics of the distinctive echo are given.

  4. Grayia spinosa (Hook.) Moq.: spiny hopsage

    Treesearch

    Nancy L. Shaw; Marshall R. Haferkamp; Emerenciana G. Hurd

    2008-01-01

    The genus Grayia Hook. & Arn., named for the American botanist Asa Gray, contains a single species - spiny hopsage (table 1). Plants are erect to rounded, summer-deciduous shrubs 0.3 to 1.2 (1.5) m tall. Branches are divergent and thorn-tipped, with whitish gray to brownish bark that exfoliates in long strips. Leaves are gray-green, alternate, entire, and fleshy,...

  5. Ultrastructure and chemical composition of the proboscis hooks of Acanthocephalus lucii (Müller, 1776) (Acanthocephala: Palaeacanthocephala) using X-ray elemental analysis.

    PubMed

    Brázová, Tímea; Poddubnaya, Larisa G; Miss, Noemí Ramírez; Hanzelová, Vladimíra

    2014-12-01

    The ultrastructure and chemical composition of the proboscis hooks and surrounding tegument of Acanthocephalus lucii (Müller, 1776), a parasite of European perch, Perca fluviatilis Linnaeus, were examined using scanning (SEM) and transmission (TEM) electron microscopy and X-ray microanalysis (EDXA). The blade of middle hooks consists of three layers: an outer homogeneous layer, an inner heterogeneous layer and a central core. TEM observation revealed the presence of hollow tubes, which spaced the central core; fibrous inner hook layer surrounded by an electron-dense margin and the basal tegumental layer filled with electron-dense bodies and outer layer. We found for the first time that the so-called 'epidermal covering' surrounding of the exposed hook blade (outer hook layer) is a modified striped portion of the tegumental layer and there are no special contact sites between these two morphologically different structures, i.e. striped layer of the syncytial tegument and following proper outer hook layer, which is a homogeneous, moderately electron-dense layer of -0.3 μm in thickness. The hook root is embedded into subtegumental fibrous layer. X-ray microanalysis of both the surface and internal parts of A. lucii hooks demonstrated the presence of calcium, magnesium, phosphorus and sulphur. The highest concentration of sulphur was recorded at the tip of hooks, whereas the middle part of the hooks was most rich in calcium, phosphorus and magnesium. The proximal part of the hooks contained lower concentrations of sulphur, calcium and phosphorus. In the proboscis tegument, only two elements, calcium and silicon, were found. The differences observed in the chemical composition of the hook 'epidermal covering' and the proboscis tegument support our ultrastructural findings that the hook tegumental covering is a modified structure compared with that of the general proboscis tegument.

  6. Importance of understanding landscape biases in USGS gage locations: Implications and solutions for managers

    USGS Publications Warehouse

    Wagner, Tyler; DeWeber, Jefferson Tyrell; Tsang, Yin-Phan; Krueger, Damon; Whittier, Joanna B.; Infante, Dana M.; Whelan, Gary

    2014-01-01

    Flow and water temperature are fundamental properties of stream ecosystems upon which many freshwater resource management decisions are based. U.S. Geological Survey (USGS) gages are the most important source of streamflow and water temperature data available nationwide, but the degree to which gages represent landscape attributes of the larger population of streams has not been thoroughly evaluated. We identified substantial biases for seven landscape attributes in one or more regions across the conterminous United States. Streams with small watersheds (<10 km2) and at high elevations were often underrepresented, and biases were greater for water temperature gages and in arid regions. Biases can fundamentally alter management decisions and at a minimum this potential for error must be acknowledged accurately and transparently. We highlight three strategies that seek to reduce bias or limit errors arising from bias and illustrate how one strategy, supplementing USGS data, can greatly reduce bias.

  7. Advances in Social Circles Detection

    DTIC Science & Technology

    2015-07-01

    Acknowledgements En primer lugar , agradecer a Roberto Paredes y Paolo Rosso la oportunidad de trabajar en el centro de investigación PRHLT, gracias a...Politècnica De València Technology Transfer Office_CTT UNIVERSITAT POLITÈCNICA DE VALÈNCIA - ABSTRACT Advances in Social Circles Detection Report Title...Our work opens the door to several lines of future work. Universitat Politècnica de València Trabajo de Fin de Máster Advances in Social Circles

  8. Comparison of concentric needle versus hooked-wire electrodes in the canine larynx.

    PubMed

    Jaffe, D M; Solomon, N P; Robinson, R A; Hoffman, H T; Luschei, E S

    1998-05-01

    The use of a specific electrode type in laryngeal electromyography has not been standardized. Laryngeal electromyography is usually performed with hooked-wire electrodes or concentric needle electrodes. Hooked-wire electrodes have the advantage of allowing laryngeal movement with ease and comfort, whereas the concentric needle electrodes have benefits from a technical aspect and may be advanced, withdrawn, or redirected during attempts to appropriately place the electrode. This study examines whether hooked-wire electrodes permit more stable recordings than standard concentric needle electrodes at rest and after large-scale movements of the larynx and surrounding structures. A histologic comparison of tissue injury resulting from placement and removal of the two electrode types is also made by evaluation of the vocal folds. Electrodes were percutaneously placed into the thyroarytenoid muscles of 10 adult canines. Amplitude of electromyographic activity was measured and compared during vagal stimulation before and after large-scale laryngeal movements. Signal consistency over time was examined. Animals were killed and vocal fold injury was graded and compared histologically. Waveform morphology did not consistently differ between electrode types. The variability of electromyographic amplitude was greater for the hooked-wire electrode (p < 0.05), whereas the mean amplitude measures before and after large-scale laryngeal movements did not differ (p > 0.05). Inflammatory responses and hematoma formation were also similar. Waveform morphology of electromyographic signals registered from both electrode types show similar complex action potentials. There is no difference between the hooked-wire electrode and the concentric needle electrode in terms of electrode stability or vocal fold injury in the thyroarytenoid muscle after large-scale laryngeal movements.

  9. 49 CFR 393.134 - What are the rules for securing roll-on/roll-off or hook lift containers?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... or hook lift containers? 393.134 Section 393.134 Transportation Other Regulations Relating to... for securing roll-on/roll-off or hook lift containers? (a) Applicability. The rules in this section apply to the transportation of roll-on/roll-off or hook lift containers. (b) Securement of a roll-on...

  10. 49 CFR 393.134 - What are the rules for securing roll-on/roll-off or hook lift containers?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... or hook lift containers? 393.134 Section 393.134 Transportation Other Regulations Relating to... for securing roll-on/roll-off or hook lift containers? (a) Applicability. The rules in this section apply to the transportation of roll-on/roll-off or hook lift containers. (b) Securement of a roll-on...

  11. Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study.

    PubMed

    Lee, Cheng-Hung; Shih, Cheng-Min; Huang, Kui-Chou; Chen, Kun-Hui; Hung, Li-Kun; Su, Kuo-Chih

    2016-11-01

    Clinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri-implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (FEA). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for FEA. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18 mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young's modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. 75 FR 76890 - Fisheries of the Caribbean, Gulf of Mexico, and South Atlantic; Snapper-Grouper Fishery Off the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-09

    ... snapper-grouper), requiring the use of non-stainless steel circle hooks when fishing for snapper- grouper species with hook and line gear north of 28[deg] N. latitude in the South Atlantic EEZ, and implementing... minimizing the negative socio-economic effects on fishing communities. Amendment 17A was approved by the...

  13. Physiological response to hooking stress in hatchery and wild rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Wydoski, R.S.; Wedemeyer, G.A.; Nelson, N. C.

    1976-01-01

    This study evaluated the physiological response of rainbow trout to hooking stress after being played under standardized conditions (0–5 min) and estimated the time needed for recovery (to 72 h). Plasma osmolality and chloride measurements were used to evaluate osmoregulatory disturbances and gill ion-exchange function, and plasma glucose was used as an index of the generalized nonspecific physiological stress response. Hooking stress caused more severe blood chemistry differences in hatchery fish than in wild trout. Also, hooking stress imposed a greater stress on larger than on smaller hatchery rainbow trout. Higher water temperatures aggravated the delayed hyperglycemia and hyperchloremia in both hatchery and wild trout but only about 3 days were needed for recovery at 4, 10, or 20 C.

  14. The remarkable vision of Robert Hooke (1635-1703): first observer of the microbial world.

    PubMed

    Gest, Howard

    2005-01-01

    Robert Hooke played important roles in the early development of the Royal Society of London. As Curator of Experiments of the Society, he became a pioneering microscopist, prolific inventor, astronomer, geologist, architect, and an effective surveyor of the City of London following the Great Fire of 1666. Hooke's Micrographia (1665) revealed the microscopic structures of numerous biological and inorganic objects and became an important source of information for later studies. Aside from the body of detailed observations reported and depicted in Micrographia, the Preface is in itself an extraordinary document that exhibits Hooke's fertile mind, philosophical insights, and rare ability to look into the future.

  15. Reliability of the Forest Service type rain gage

    Treesearch

    G. L. Hayes

    1942-01-01

    The Forest Service type rain-gage was originated by W. B. Osborne of the Portland, Oreg., office of the U. S. Forest Service to meet a need for reliable rainfall measurements at low cost. Many hundreds of them, over 700 on the national forests of northern Idaho and western Montana alone, are now being used during the summer months as aids to forest-fire control...

  16. Jurassic onychites (arm hooks) from squid-like cephalopods from the Wessex Basin, southern England

    NASA Astrophysics Data System (ADS)

    Hart, Malcolm; Hughes, Zoe; Page, Kevin; Price, Gregory; Smart, Christopher

    2017-04-01

    Modern coleoid (squid-like) cephalopods have arms that carry arrays of both suckers and hardened, organic hooks. Fossil arm hooks have been known since the description of Sternberg in 1823, although he identified them as algal remains. During the twentieth century there have been a number of descriptions of hooks (Kulicki & Szaniawski, 1972; Clarke & Engeser, 1988). Kulicki & Szaniawski (1972) gave these 'morphotypes' names using a binomial classification though, with many lacking defined (and figured) holotypes and, in some cases, only one recorded specimen, some of their designations should be regarded as invalid. Some of their morphotypes have, however, been reported widely, from DSDP sites on the Falkland Plateau as well as New Zealand, Germany, Svalbard, Poland and the United Kingdom. Exceptional soft-bodied preservation of species such as Belemnotheutis antiquus (Pearce, 1847) from the Callovian-Oxfordian of Wiltshire (UK) and Clarkeiteuthis montefiore (Buckman, 1880) from the Sinemurian of Dorset (UK) has allowed the identification of the host animal of some morphotypes, though the majority remain un-attributable. In the Christian Malford lagerstätte (Upper Callovian) of Wiltshire large numbers of hooks (including forms described as Acanthuncus, Arites, Deinuncus, Falcuncus, Longuncus and Paraglycerites) are found associated with an abundance of statoliths (cephalopod 'ear bones') and macrofossil evidence of both belemnites and teuthids, some of which includes exceptional soft-bodied preservation (Wilby et al., 2004; Hart et al., 2016). Many of the hook types cannot, at present be assigned to known taxa of coleoid. In Belemnotheutis antiquus there appears to be one form of simple, slightly curved hook and their shape appears to remain constant throughout the Callovian -Kimmeridgian interval. In the Lias Group, hooks of Clarkeiteuthis are very different, with inflated, often bi-lobate bases and each arm often characterised by the presence of different shapes

  17. The return of Phineas Gage: clues about the brain from the skull of a famous patient.

    PubMed

    Damasio, H; Grabowski, T; Frank, R; Galaburda, A M; Damasio, A R

    1994-05-20

    When the landmark patient Phineas Gage died in 1861, no autopsy was performed, but his skull was later recovered. The brain lesion that caused the profound personality changes for which his case became famous has been presumed to have involved the left frontal region, but questions have been raised about the involvement of other regions and about the exact placement of the lesion within the vast frontal territory. Measurements from Gage's skull and modern neuroimaging techniques were used to reconstitute the accident and determine the probable location of the lesion. The damage involved both left and right prefrontal cortices in a pattern that, as confirmed by Gage's modern counterparts, causes a defect in rational decision making and the processing of emotion.

  18. 78 FR 23864 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Catcher/Processors Using Hook...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-23

    ... Catcher/Processors Using Hook-and-line Gear in the Western Regulatory Area of the Gulf of Alaska AGENCY.../processors (C/Ps) using hook-and-line gear in the Western Regulatory Area of the Gulf of Alaska (GOA). This... catch apportioned to C/Ps using hook-and-line gear in the Western Regulatory Area of the GOA. DATES...

  19. 77 FR 11776 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Catcher/Processors Using Hook...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    .../Processors Using Hook-and-Line Gear in the Central Regulatory Area of the Gulf of Alaska AGENCY: National... (C/Ps) using hook-and-line gear in the Central Regulatory Area of the Gulf of Alaska (GOA). This... catch apportioned to C/Ps using hook-and-line gear in the Central Regulatory Area of the GOA. DATES...

  20. Development of lightweight graphite/polyimide sandwich panels. Phase 2: Thin gage material manufacture

    NASA Technical Reports Server (NTRS)

    Merlette, J. B.

    1972-01-01

    Thin gage materials selected and the rationale for their basic requirements are discussed. The resin used in all prepreg manufacture is Monsanto RS-6234 polyimide. The selected fiber for core manufacture is Hercules HT-S, and the selected fiber for face sheets is Hercules HM-S. The technique for making thin gage prepreg was to wind spread carbon fiber tows into a resin film on a large drum. This technique was found to be superior to others investigated. A total of 22 pounds of 1 to 2 mil/ply prepreg was fabricated for use on the program.

  1. A Conversion of Wheatstone Bridge to Current-Loop Signal Conditioning for Strain Gages

    NASA Technical Reports Server (NTRS)

    Anderson, Karl F.

    1995-01-01

    Current loop circuitry replaced Wheatstone bridge circuitry to signal-condition strain gage transducers in more than 350 data channels for two different test programs at NASA Dryden Flight Research Center. The uncorrected test data from current loop circuitry had a lower noise level than data from comparable Wheatstone bridge circuitry, were linear with respect to gage-resistance change, and were uninfluenced by varying lead-wire resistance. The current loop channels were easier for the technicians to set up, verify, and operate than equivalent Wheatstone bridge channels. Design choices and circuit details are presented in this paper in addition to operational experience.

  2. High temperature static strain gage development contract, tasks 1 and 2

    NASA Technical Reports Server (NTRS)

    Hulse, C. O.; Bailey, R. S.; Grant, H. P.; Przybyszewski, J. S.

    1987-01-01

    Results are presented for the first two tasks to develop resistive strain gage systems for use up to 1250 K on blades and vanes in gas turbine engines under tests. The objective of these two tasks was to further improve and evaluate two static strain gage alloys identified as candidates in a previous program. Improved compositions were not found for either alloy. Further efforts on the Fe-11.9Al-10.6Cr weigth percent alloy were discontinued because of time dependent drift problems at 1250 K in air. When produced as a 6.5 micrometer thick sputtered film, the Pd-13Cr weight percent alloys is not sufficiently stable for this use in air at 1250 K and a protective overcoat system will need to be developed.

  3. Circles South East: the first 10 years 2002-2012.

    PubMed

    Bates, Andrew; Williams, Dominic; Wilson, Chris; Wilson, Robin J

    2014-07-01

    This article describes the first 10 years of the implementation of Circles of Support and Accountability (Circles) in the management of sexual offenders in South-East England by Circles South East (CSE). The Circles of 71 core members are reviewed in detail, with reference to demographic data, offense and sentencing histories, risk assessment data, and considerations regarding Multi-Agency Public Protection Arrangements. A group of 71 comparison subjects who were referred to CSE and deemed suitable for but did not receive the service was identified. Follow-up behaviors of both groups are examined (including all forms of reconviction, breach of orders, and prison recall). Over a comparable follow-up period of 55 months, the incidence of violent and contact sexual reconviction in the comparison group was significantly higher than for the Circles cohort. Comparisons are made between expected and actual levels of sexual reconviction, with the Circles cohort showing lower than expected rate of sexual reconviction but not to a statistically significant degree. © The Author(s) 2013.

  4. Exploring Factors That Influence Quality Literature Circles

    ERIC Educational Resources Information Center

    Young, Chase; Mohr, Kathleen A. J.

    2018-01-01

    Research indicates that literature circles are an authentic means for literacy development that students typically enjoy. To better understand the potential value and to add to the research base regarding literature circles, this study, involving 17 fourth graders, explores factors that may influence the quality of literature discussions,…

  5. Anharmonic Vibrations of an "Ideal" Hooke's Law Oscillator

    ERIC Educational Resources Information Center

    Thomchick, John; McKelvey, J. P.

    1978-01-01

    Presents a model describing the vibrations of a mass connected to fixed supports by "ideal" Hooke's law springs which may serve as a starting point in the study of the properties of irons in a crystal undergoing soft mode activated transition. (SL)

  6. Circles of Support and Personalization: Exploring the Economic Case

    ERIC Educational Resources Information Center

    Wistow, Gerald; Perkins, Margaret; Knapp, Martin; Bauer, Annette; Bonin, Eva-Maria

    2016-01-01

    Circles of Support aim to enable people with learning disabilities (and others) to live full lives as part of their communities. As part of a wider study of the economic case for community capacity building conducted from 2012 to 2014, we conducted a mixed methods study of five Circles in North West England. Members of these Circles were…

  7. Cost-effectiveness of the U.S. Geological Survey's stream-gaging programs in Massachusetts and Rhode Island

    USGS Publications Warehouse

    Gadoury, R.A.; Smath, J.A.; Fontaine, R.A.

    1985-01-01

    The report documents the results of a study of the cost-effectiveness of the U.S. Geological Survey 's continuous-record stream-gaging programs in Massachusetts and Rhode Island. Data uses and funding sources were identified for 91 gaging stations being operated in Massachusetts are being operated to provide data for two special purpose hydrologic studies, and they are planned to be discontinued at the conclusion of the studies. Cost-effectiveness analyses were performed on 63 continuous-record gaging stations in Massachusetts and 15 stations in Rhode Island, at budgets of $353,000 and $60,500, respectively. Current operations policies result in average standard errors per station of 12.3% in Massachusetts and 9.7% in Rhode Island. Minimum possible budgets to maintain the present numbers of gaging stations in the two States are estimated to be $340,000 and $59,000, with average errors per station of 12.8% and 10.0%, respectively. If the present budget levels were doubled, average standards errors per station would decrease to 8.1% and 4.2%, respectively. Further budget increases would not improve the standard errors significantly. (USGS)

  8. A double standard for "Hooking Up": How far have we come toward gender equality?

    PubMed

    Allison, Rachel; Risman, Barbara J

    2013-09-01

    While sexual attitudes have liberalized in the past half century, research is mixed as to whether attitudes have become less gendered over time. Recent studies on college students' sexual and romantic relationships suggest that a sexual double standard continues to organize sexuality on many campuses. Data from the Online College Social Life Survey shed light on students' evaluation of casual sex, or "hooking up." In addition to exploring gendered attitudinal patterns, we use gender structure theory to explore how individual characteristics and normative expectations of campus group affiliations shape attitudes. While three quarters of students do not hold different standards for men and women's hooking up, attitudes are more conservative than liberal, with almost half of students losing respect for men and women who hook up "a lot." However, men are more likely to hold a traditional double standard, while women are more likely to espouse egalitarian conservative attitudes. Individual characteristics, including age, religion, race, social class and sexual orientation are frequently related to sexual attitudes, as are number of hook ups, fraternity/sorority affiliation and varsity athletic participation. Published by Elsevier Inc.

  9. Arthroscopic evaluation for omalgia patients undergoing the clavicular hook plate fixation of distal clavicle fractures

    PubMed Central

    2014-01-01

    Background The aim of this study is to investigate the anatomic changes in the shoulder joints responsible for omalgia after the clavicular hook plate fixation under arthroscope. Methods Arthroscopic examination was carried out for 12 omalgia patients who underwent clavicular hook plate fixation due to distal clavicle fractures. Functional outcome of shoulder was measured by the Japanese Orthopaedic Association (JOA) score before and after the withdrawal of the fixation plate. Results The rotator cuff compression by the clavicular hook was arthroscopically observed in 11 of the 12 cases. The JOA scores of the shoulder were significantly improved at 1 month after the withdrawal of the fixation plate (pain, 28 ± 2.4 vs. 15 ± 5.2; function, 19.2 ± 1.0 vs. 11.7 ± 1.9; range of movements, 26.8 ± 2.6 vs. 14.8 ± 3.4) compared with before. Conclusions The impingement of the hook to the rotator cuff may be the main cause for the omalgia. The appropriate hook and plate that fit to the curve of the clavicle as well as the acromion are necessary to decrease the severity of omalgia. PMID:24917508

  10. The influence of pornography on sexual scripts and hooking up among emerging adults in college.

    PubMed

    Braithwaite, Scott R; Coulson, Gwen; Keddington, Krista; Fincham, Frank D

    2015-01-01

    The explosive growth in access to the Internet has led to a commensurate increase in the availability, anonymity, and affordability of pornography. An emerging body of research has shown associations between pornography and certain behaviors and attitudes; yet, how pornography actually influences these outcomes has not been documented. In two studies (Study 1 N = 969; Study 2 N = 992) we examined the hypothesis that pornography influences potentially risky sexual behavior (hooking up) among emerging adults via sexual scripts. Our results demonstrate that more frequent viewing of pornography is associated with a higher incidence of hooking up and a higher number of unique hook up partners. We replicated these effects both cross-sectionally and longitudinally while accounting for the stability of hook ups over the course of an academic semester. We also demonstrated that more frequent viewing of pornography is associated with having had more previous sexual partners of all types, more one occasion sexual partners ("one night stands"), and plans to have a higher number of sexual partners in the future. Finally, we provided evidence that more permissive sexual scripts mediated the association between more frequent pornography viewing and hooking up. We discuss these findings with an eye toward mitigating potential personal and public health risks among emerging adults.

  11. Sets that Contain Their Circle Centers

    ERIC Educational Resources Information Center

    Martin, Greg

    2008-01-01

    Say that a subset S of the plane is a "circle-center set" if S is not a subset of a line, and whenever we choose three non-collinear points from S, the center of the circle through those three points is also an element of S. A problem appearing on the Macalester College Problem of the Week website stated that a finite set of points in the plane,…

  12. Gage restraint measurement system comparison tests : railbound and hi-rail vehicles

    DOT National Transportation Integrated Search

    2003-12-01

    Comparative tests were conducted to evaluate the gage restraint measurement system (GRMS) testing capabilities of a railbound GRMS vehicle, Federal Railroad Administration's (FRA's) T-6, and a hi-rail vehicle, Holland Company's TrackStar GRMS system....

  13. Three Concentric Circles: Young Chinese English Learners' Perceptions of Purposeful Audiences

    ERIC Educational Resources Information Center

    Liu, Jack Jinghui

    2015-01-01

    English learners have more access to communicate with different purposeful audiences across the Three Concentric Circles of English (Kachu, 1985): the Inner Circle, the Outer Circle and the Expanding Circle. However, young language learners' purposeful audience as a focus of communication has not been emphasized as much as other linguistic…

  14. 13. VIEW OF SHEFFIELD GAGE, USED TO MEASURE ROUNDNESS OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. VIEW OF SHEFFIELD GAGE, USED TO MEASURE ROUNDNESS OF WEAPON PARTS, AS PART OF THE FINAL PARTS INSPECTION PROCESS. (6/2/67) - Rocky Flats Plant, Non-Nuclear Production Facility, South of Cottonwood Avenue, west of Seventh Avenue & east of Building 460, Golden, Jefferson County, CO

  15. Fairy circle landscapes under the sea

    PubMed Central

    Ruiz-Reynés, Daniel; Gomila, Damià; Sintes, Tomàs; Hernández-García, Emilio; Marbà, Núria; Duarte, Carlos M.

    2017-01-01

    Short-scale interactions yield large-scale vegetation patterns that, in turn, shape ecosystem function across landscapes. Fairy circles, which are circular patches bare of vegetation within otherwise continuous landscapes, are characteristic features of semiarid grasslands. We report the occurrence of submarine fairy circle seascapes in seagrass meadows and propose a simple model that reproduces the diversity of seascapes observed in these ecosystems as emerging from plant interactions within the meadow. These seascapes include two extreme cases, a continuous meadow and a bare landscape, along with intermediate states that range from the occurrence of persistent but isolated fairy circles, or solitons, to seascapes with multiple fairy circles, banded vegetation, and “leopard skin” patterns consisting of bare seascapes dotted with plant patches. The model predicts that these intermediate seascapes extending across kilometers emerge as a consequence of local demographic imbalances along with facilitative and competitive interactions among the plants with a characteristic spatial scale of 20 to 30 m, consistent with known drivers of seagrass performance. The model, which can be extended to clonal growth plants in other landscapes showing fairy rings, reveals that the different seascapes observed hold diagnostic power as to the proximity of seagrass meadows to extinction points that can be used to identify ecosystems at risks. PMID:28782035

  16. [Complications of treatment of acromioclavicular joint dislocation and unstable distal clavicular fracture with clavicular hook plate].

    PubMed

    Zhu, Yi-Yong; Cui, Heng-Yan; Jiang, Pan-Qiang; Wang, Jian-Liang

    2013-11-01

    To investigate the causes and prevention of the complications about treatment of acromioclavicular joint dislocation (Tossy III) and unstable distal clavicular fracture (Neer II) with clavicular hook plate. From January 2001 to December 2011, 246 patients with acromioclavicular joint dislocation (Tossy III) and 222 patients with unstable distal clavicular fracture (Neer II) were treated with acromioclvicular hook plate fixation,including 348 males and 120 females with an average age of 45.4 years old ranging from 21 to 80 years old. The mean time from injury to operation was 30.8 hours (ranged from 1 h to 15 d). All patients had normal shoulder function before injury. According to Karlsson evaluation standard, the cases with excellent and good function of the shoulder joint were regarded as the normal group, and the cases with poor function of shoulder joint as the abnormal group. The comparison of the range of forward flexion,backward stretch, adduction, abduction and elevation of shoulder joints between two groups was performed. The data of impingement, subacromial osteolysis, acromioclavicular arthritis, clavicular stress fracture, downward acromioclavicular joint subluxation, hook cut-out and hook break were summarized. All patients were followed up from 8 to 48 months with an average of 12.5 months. The results were excellent in 308 cases,good in 76,and poor in 84 according to Karlsson evaluation. The excellent and good rate was 82.1%. The difference of the range of forward flexion, backward stretch, adduction, abduction and elevation of shoulder joints between two groups had a statistically significant difference (P < 0.01). Among 84 poor cases, there were 41 (8.76%) in acromial impingement or inadequate place of plate hook, 12 (2.56%) with subacromial osteolysis or/and bursitis, 10 (2.14%) with acromioclavicular arthritis or painful shoulder caused by delayed dirigation,7 (1.50%) with clavicular stress fracture or interal plate upward, 6 (1.28%) with

  17. Assign Roles to Get Literature Circles Rolling

    ERIC Educational Resources Information Center

    Curriculum Review, 2005

    2005-01-01

    This article briefly describes a role-playing exercise designed to break the ice in a classroom literature circle from The Ultimate Small-Group Reading How-To Book: Building Comprehension through SmallGroup Instruction, written by Gail Saunders-Smith. The members of a literature circle participate in the group discussion according to the…

  18. Suitability of Strain Gage Sensors for Integration into Smart Sport Equipment: A Golf Club Example.

    PubMed

    Umek, Anton; Zhang, Yuan; Tomažič, Sašo; Kos, Anton

    2017-04-21

    Wearable devices and smart sport equipment are being increasingly used in amateur and professional sports. Smart sport equipment employs various sensors for detecting its state and actions. The correct choice of the most appropriate sensor(s) is of paramount importance for efficient and successful operation of sport equipment. When integrated into the sport equipment, ideal sensors are unobstructive, and do not change the functionality of the equipment. The article focuses on experiments for identification and selection of sensors that are suitable for the integration into a golf club with the final goal of their use in real time biofeedback applications. We tested two orthogonally affixed strain gage (SG) sensors, a 3-axis accelerometer, and a 3-axis gyroscope. The strain gage sensors are calibrated and validated in the laboratory environment by a highly accurate Qualisys Track Manager (QTM) optical tracking system. Field test results show that different types of golf swing and improper movement in early phases of golf swing can be detected with strain gage sensors attached to the shaft of the golf club. Thus they are suitable for biofeedback applications to help golfers to learn repetitive golf swings. It is suggested that the use of strain gage sensors can improve the golf swing technical error detection accuracy and that strain gage sensors alone are enough for basic golf swing analysis. Our final goal is to be able to acquire and analyze as many parameters of a smart golf club in real time during the entire duration of the swing. This would give us the ability to design mobile and cloud biofeedback applications with terminal or concurrent feedback that will enable us to speed-up motor skill learning in golf.

  19. Suitability of Strain Gage Sensors for Integration into Smart Sport Equipment: A Golf Club Example

    PubMed Central

    Umek, Anton; Zhang, Yuan; Tomažič, Sašo; Kos, Anton

    2017-01-01

    Wearable devices and smart sport equipment are being increasingly used in amateur and professional sports. Smart sport equipment employs various sensors for detecting its state and actions. The correct choice of the most appropriate sensor(s) is of paramount importance for efficient and successful operation of sport equipment. When integrated into the sport equipment, ideal sensors are unobstructive, and do not change the functionality of the equipment. The article focuses on experiments for identification and selection of sensors that are suitable for the integration into a golf club with the final goal of their use in real time biofeedback applications. We tested two orthogonally affixed strain gage (SG) sensors, a 3-axis accelerometer, and a 3-axis gyroscope. The strain gage sensors are calibrated and validated in the laboratory environment by a highly accurate Qualisys Track Manager (QTM) optical tracking system. Field test results show that different types of golf swing and improper movement in early phases of golf swing can be detected with strain gage sensors attached to the shaft of the golf club. Thus they are suitable for biofeedback applications to help golfers to learn repetitive golf swings. It is suggested that the use of strain gage sensors can improve the golf swing technical error detection accuracy and that strain gage sensors alone are enough for basic golf swing analysis. Our final goal is to be able to acquire and analyze as many parameters of a smart golf club in real time during the entire duration of the swing. This would give us the ability to design mobile and cloud biofeedback applications with terminal or concurrent feedback that will enable us to speed-up motor skill learning in golf. PMID:28430147

  20. Fiber-Optic Strain-Gage Tank Level Measurement System for Cryogenic Propellants

    NASA Technical Reports Server (NTRS)

    Figueroa, Fernando; Mitchell, Mark; Langford, Lester

    2004-01-01

    Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult problem. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. These methods are designed to measure tank-level, but when the fluids are in supercritical state, the liquid-gas interface disappears. Furthermore, there is a need for a non-intrusive measurement system; that is, the sensors should not require tank modifications and/or disturb the fluids. This paper describes a simple, but effective method to determine propellant mass by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a much better quality signal across all regimes during an engine test. Experimental results also show that the use of fiber optic strain gages (FOSG) over classic foil strain gages extends the operation time (before the system becomes uncalibrated), and increases accuracy. Finally, a procedure is defined whereby measurements from the FOSG mounted on the tank supporting structure are compensated using measurements of a FOSG mounted on a reference plate and temperature measurements of the structure. Results describing the performance of a deployed system that measures tank level during propulsion tests are included.

  1. Automation Hooks Architecture for Flexible Test Orchestration - Concept Development and Validation

    NASA Technical Reports Server (NTRS)

    Lansdowne, C. A.; Maclean, John R.; Winton, Chris; McCartney, Pat

    2011-01-01

    The Automation Hooks Architecture Trade Study for Flexible Test Orchestration sought a standardized data-driven alternative to conventional automated test programming interfaces. The study recommended composing the interface using multicast DNS (mDNS/SD) service discovery, Representational State Transfer (Restful) Web Services, and Automatic Test Markup Language (ATML). We describe additional efforts to rapidly mature the Automation Hooks Architecture candidate interface definition by validating it in a broad spectrum of applications. These activities have allowed us to further refine our concepts and provide observations directed toward objectives of economy, scalability, versatility, performance, severability, maintainability, scriptability and others.

  2. Use of the S-hook for Pelvic Fixation in Rib-Based Treatment of Early-Onset Scoliosis: A Multicenter Study.

    PubMed

    Ramirez, Norman; Flynn, John M; Smith, John T; Vitale, Michael; Sturm, Peter F; DʼAmato, Charles; Samdani, Amer; Machiavelli, Raul; El-Hawary, Ron

    2015-06-01

    Retrospective review. The purpose of this study was to evaluate how several preoperative variables affect the outcome using the rib-to-pelvis S-hook constructs of a rib-based distraction implant (Vertical Expandable Prosthetic Titanium Rib). Rib-to-pelvis fixation with S-hooks is one of the options for distal anchoring of rib-based distraction growing rod construct to control early-onset spinal deformity. Since the initial report, the indications of pelvic fixation with S-hooks have been extended and modified. This is an institutional review board-approved retrospective study of patients who underwent rib-based growing rod system surgery-rib-to-pelvis construct with Dunn-McCarthy S-hook. Data evaluation included history, physical examination, preoperative and postoperative radiographs, surgical variables, and complications. Sixty-five patients were evaluated; 38 were male and 27 were female. Mean age at initial procedure was 71 months. The mean follow-up was 46 months. There was a statistically significant improvement of the immediate postoperative Cobb angle and the last follow-up Cobb angle (P < 0.0001). Fifty percent of the patients (32/65) had S-hook-related complications. The most common complication was sliding of the S-hook out of the iliac crest, followed by infection, neuropathic pain, distal migration of more than 2 cm, fracture of the hook, and bursitis. The complications were related to the preoperative ambulatory status, the use of end-to-end rod connectors, surgical time, and not positioning the hook over the central one-third of the iliac crest at the initial implantation. The use of the S-hook as a pelvic attachment of the rib-based system is indicated in nonambulatory patients with progressive, early-onset scoliosis curve with a lack of adequate anchor at the lumbar spine. Several technical factors should be considered to reduce the complication rate. 3.

  3. Low temperature coefficient of resistance and high gage factor in beryllium-doped silicon

    NASA Technical Reports Server (NTRS)

    Robertson, J. B.; Littlejohn, M. A.

    1974-01-01

    The gage factor and resistivity of p-type silicon doped with beryllium was studied as a function of temperature, crystal orientation, and beryllium doping concentration. It was shown that the temperature coefficient of resistance can be varied and reduced to zero near room temperature by varying the beryllium doping level. Similarly, the magnitude of the piezoresistance gage factor for beryllium-doped silicon is slightly larger than for silicon doped with a shallow acceptor impurity such as boron, whereas the temperature coefficient of piezoresistance is about the same for material containing these two dopants. These results are discussed in terms of a model for the piezoresistance of compensated p-type silicon.

  4. Linking Statistically- and Physically-Based Models for Improved Streamflow Simulation in Gaged and Ungaged Areas

    NASA Astrophysics Data System (ADS)

    Lafontaine, J.; Hay, L.; Archfield, S. A.; Farmer, W. H.; Kiang, J. E.

    2014-12-01

    The U.S. Geological Survey (USGS) has developed a National Hydrologic Model (NHM) to support coordinated, comprehensive and consistent hydrologic model development, and facilitate the application of hydrologic simulations within the continental US. The portion of the NHM located within the Gulf Coastal Plains and Ozarks Landscape Conservation Cooperative (GCPO LCC) is being used to test the feasibility of improving streamflow simulations in gaged and ungaged watersheds by linking statistically- and physically-based hydrologic models. The GCPO LCC covers part or all of 12 states and 5 sub-geographies, totaling approximately 726,000 km2, and is centered on the lower Mississippi Alluvial Valley. A total of 346 USGS streamgages in the GCPO LCC region were selected to evaluate the performance of this new calibration methodology for the period 1980 to 2013. Initially, the physically-based models are calibrated to measured streamflow data to provide a baseline for comparison. An enhanced calibration procedure then is used to calibrate the physically-based models in the gaged and ungaged areas of the GCPO LCC using statistically-based estimates of streamflow. For this application, the calibration procedure is adjusted to address the limitations of the statistically generated time series to reproduce measured streamflow in gaged basins, primarily by incorporating error and bias estimates. As part of this effort, estimates of uncertainty in the model simulations are also computed for the gaged and ungaged watersheds.

  5. Astronaut James Newman with latch hook for tether device

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Astronaut James H. Newman, mission specialist, shows off a latch hook for a tether device used during the STS-51 extravehicular activity (EVA) on September 16, 1993. Newman, on Discovery's middeck, appears surrounded by sleep restraints.

  6. Utilizing Photogrammetry and Strain Gage Measurement to Characterize Pressurization of Inflatable Modules

    NASA Technical Reports Server (NTRS)

    Mohammed, Anil

    2011-01-01

    This paper focuses on integrating a large hatch penetration into inflatable modules of various constructions. This paper also compares load predictions with test measurements. The strain was measured by utilizing photogrammetric methods and strain gages mounted to select clevises that interface with the structural webbings. Bench testing showed good correlation between strain data collected from an extensometer and photogrammetric measurements, even when the material transitioned from the low load to high load strain region of the curve. The full-scale torus design module showed mixed results as well in the lower load and high strain regions. After thorough analysis of photogrammetric measurements, strain gage measurements, and predicted load, the photogrammetric measurements seem to be off by a factor of two.

  7. Physiological stress and post-release mortality of white marlin (Kajikia albida) caught in the United States recreational fishery.

    PubMed

    Schlenker, Lela S; Latour, Robert J; Brill, Richard W; Graves, John E

    2016-01-01

    White marlin, a highly migratory pelagic marine fish, support important commercial and recreational fisheries throughout their range in the tropical and subtropical Atlantic Ocean. More than 10 000 individuals can be caught annually in the United States recreational fishery, of which the vast majority are captured on circle hooks and released alive. The probability of post-release mortality of white marlin released from circle hooks has been documented to be <0.02, but the associated physiological stress resulting from capture and handling techniques has not been characterized despite its importance for understanding the health of released fish. We examined the physiological response of 68 white marlin caught on circle hooks in the recreational fishery and followed the fate of 22 of these fish with pop-up satellite archival tags programmed to release after 30 days. Measures of plasma sodium, chloride, glucose and lactate concentrations taken from fish that were briefly and consistently (mean = 120 s, standard deviation = 40 s) removed from the water increased with angling time, but post-release mortality was inversely related to angling time. The probability of post-release mortality was predicted by elevated plasma potassium concentrations and was more than 10 times greater than has been previously reported for white marlin caught on circle hooks that were not removed from the water. This disparity in estimates of post-release mortality suggests that removal of fish from the water for physiological sampling greatly heightens stress, disrupts homeostasis and thus increases the probability of post-release mortality. Our results demonstrate that elevated concentrations of plasma potassium predict mortality in white marlin and that the probability of post-release mortality is highly dependent on post-capture handling procedures.

  8. D'Nealian Handwriting versus Circle-Stick Print.

    ERIC Educational Resources Information Center

    Thurber, Donald N.

    This paper argues against teaching children to make letters using circle-stick writing. It contends that the circle-stick method requires continued pen/pencil lifts hindering rhythm or flow in the writing process and that there is little carry-over value into cursive writing as the two scripts are totally different. D'Nealian print, one type of…

  9. High-Resolution Rainfall From Radar Reflectivity and Terrestrial Rain Gages for use in Estimating Debris-Flow Susceptibility in the Day Fire, California

    NASA Astrophysics Data System (ADS)

    Hanshaw, M. N.; Schmidt, K. M.; Jorgensen, D. P.; Stock, J. D.

    2007-12-01

    Constraining the distribution of rainfall is essential to evaluating the post-fire mass-wasting response of steep soil-mantled landscapes. As part of a pilot early-warning project for flash floods and debris flows, NOAA deployed a portable truck-mounted Shared Mobile Atmospheric Research and Teaching Radar (SMART-R) to the 2006 Day fire in the Transverse Ranges of Southern California. In conjunction with a dense array of ground- based instruments, including 8 tipping-bucket rain gages located within an area of 170 km2, this C-band mobile Doppler radar provided 200-m grid cell estimates of precipitation data at fine temporal and spatial scales in burned steeplands at risk from hazardous flash floods and debris flows. To assess the utility of using this data in process models for flood and debris flow initiation, we converted grids of radar reflectivity to hourly time-steps of precipitation using an empirical relationship for convective storms, sampling the radar data at the locations of each rain gage as determined by GPS. The SMART-R was located 14 km from the farthest rain gage, but <10 km away from our intensive research area, where 5 gages are located within <1-2 km of each other. Analyses of the nine storms imaged by radar throughout the 2006/2007 winter produced similar cumulative rainfall totals between the gages and their SMART-R grid location over the entire season which correlate well on the high side, with gages recording the most precipitation agreeing to within 11% of the SMART-R. In contrast, on the low rainfall side, totals between the two recording systems are more variable, with a 62% variance between the minimums. In addition, at the scale of individual storms, a correlation between ground-based rainfall measurements and radar-based rainfall estimates is less evident, with storm totals between the gages and the SMART-R varying between 7 and 88%, a possible result of these being relatively small, fast-moving storms in an unusually dry winter. The

  10. Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients.

    PubMed

    Hanauer, Matthieu; Perentes, Jean Yannis; Krueger, Thorsten; Ris, Hans-Beat; Bize, Pierre; Schmidt, Sabine; Gonzalez, Michel

    2016-01-16

    Video-assisted thoracic surgery (VATS) is currently performed to diagnose and treat solitary pulmonary nodules (SPN). However, the intra-operative identification of deep nodules can be challenging with VATS as the lung is difficult to palpate. The aim of the study was to report the utility and the results of pre-operative computed tomography (CT)-guided hook wire localization of SPN. All records of the patients undergoing CT-guided hook wire localization prior to VATS resection for SPN between 2002 and 2013 were reviewed. The efficacy in localizing the nodule, hook wire complications, necessity to convert VATS to thoracotomy and the histology of SPN are reported. One hundred eighty-one patients (90 females, mean age 63 y, range 28-82 y) underwent 187 pulmonary resections after CT-guided hook wire localization. The mean SPN diameter was 10.3 mm (range: 4-29 mm). The mean distance of the lesion from the pleural surface was 11.6 mm (range: 0-45 mm). The mean time interval from hook wire insertion to VATS resection was 224 min (range 54-622 min). Hook wire complications included pneumothorax requiring chest tube drainage in 4 patients (2.1%) and mild parenchymal haemorrhage in 11 (5.9%) patients. Migration of the hook wire occurred in 7 patients (3.7%) although it did not affect the success of VATS resection (nodule location guided by the lung puncture site). Three patients underwent additional wedge resection by VATS during the same procedure because no lesion was identified in the surgical specimen. Conversion thoracotomy was required in 13 patients (7 %) for centrally localized lesions (6 patients) and pleural adhesions (7 patients). The mean operative time was 60 min (range 18-135 min). Pathological examination revealed a malignant lesion in 107 patients (59 %). The diagnostic yield was 98.3 %. VATS resection for SPN after CT-guided hook wire localization for SPN is safe and allows for proper diagnosis with a low thoracotomy conversion rate.

  11. A Universal Threshold for the Assessment of Load and Output Residuals of Strain-Gage Balance Data

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.; Volden, T.

    2017-01-01

    A new universal residual threshold for the detection of load and gage output residual outliers of wind tunnel strain{gage balance data was developed. The threshold works with both the Iterative and Non{Iterative Methods that are used in the aerospace testing community to analyze and process balance data. It also supports all known load and gage output formats that are traditionally used to describe balance data. The threshold's definition is based on an empirical electrical constant. First, the constant is used to construct a threshold for the assessment of gage output residuals. Then, the related threshold for the assessment of load residuals is obtained by multiplying the empirical electrical constant with the sum of the absolute values of all first partial derivatives of a given load component. The empirical constant equals 2.5 microV/V for the assessment of balance calibration or check load data residuals. A value of 0.5 microV/V is recommended for the evaluation of repeat point residuals because, by design, the calculation of these residuals removes errors that are associated with the regression analysis of the data itself. Data from a calibration of a six-component force balance is used to illustrate the application of the new threshold definitions to real{world balance calibration data.

  12. The Acoustic Reality of the Kachruvian Circles: A Rhythmic Perspective

    ERIC Educational Resources Information Center

    Low, Ee Ling

    2010-01-01

    This paper investigates whether the rhythmic properties of varieties of English found in each of the concentric circles of Kachru's model can, in any way, be elucidated by the "Three Circles" model. A measurement and comparison of the rhythm of three varieties of English: British English (from the Inner Circle), Singapore English (from…

  13. 46 CFR 32.20-20 - Liquid level gaging-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Liquid level gaging-T/ALL. 32.20-20 Section 32.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Equipment Installations § 32.20-20 Liquid level gaging—T/ALL. On tankships, the construction or...

  14. 46 CFR 32.20-20 - Liquid level gaging-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Liquid level gaging-T/ALL. 32.20-20 Section 32.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Equipment Installations § 32.20-20 Liquid level gaging—T/ALL. On tankships, the construction or...

  15. [A new type sternoclavicular hook plate for unstable sternoclavicular joint dislocation and fracture].

    PubMed

    Zhang, Chuan-Yi; Lin, Lie; Liang, Jun-Bo; Wang, Bin; Chen, Guo-Fu; Chen, Hai-Xiao

    2016-11-25

    To evaluate the therapeutic effect of a new type sternoclavicular hook plate fixation in treating unstable sternoclavicular joint dislocation and fracture. From June 2011 to December 2013, 32 patients with sternoclavicular joint dislocation and fracture were treated with a new type sternoclavicular hook plate fixation, including 24 males and 8 females with an average age of 42 years ranging from 25 to 76 years;12 patients were anterior dislocation, 5 pations were posterior dislocation, 10 patients were internal extremity of clavicle fracture and 5 patients were sternoclavicular joint dislocation combined with fracture. The anterior fracture dislocation of the sternoclavicular joint adopted standard sternoclavicular joint hook plate, and the posterior dislocation was at the distal end of the hook of the steel plate, that is, the front part of the handle of the breast was added with a nut and a gasket to prevent the re-dislocation after operation. The results were evaluated according to Rockwood score. No complication happened in all patients. X-ray and CT showed that the dislocation and fracture of the sternoclavicular joint was well reduced and the plate was on right position. All patients were followed up for 6 to 24 months with an average of 10 months. At 6 to 3 months after operation, the fracture was healing without re-dislocation of the sternoclavicular joint, the medial end of the clavicle anatomical structure were restored, functional satisfaction, in which 9 patients with the swelling around sternoclavicular joint, but no pain and other symptoms. The total Rockwood score was 12.78±1.43; the results were excellent in 24 cases, good in 8 cases. The use of the new type of locking hook plate for the treatment of unstable fracture of the sternoclavicular joint, internal fixation is reliable, high security, easy to operate, to provide a reliable method for the treatment of such trauma.

  16. Are we sinking Sandy Hook? Possible impacts of groundwater extraction to sea-level change

    NASA Astrophysics Data System (ADS)

    Johnson, C. S.; Fan, Y.; Miller, K. G.; Browning, J. V.

    2017-12-01

    The tide gauge at Sandy Hook, NJ, a spit of sand extending 8 km into Raritan Bay of New York and New Jersey, recorded a 20th century rate of relative sea-level (RSL) rise of 4.0±0.5 mm/yr, significantly higher than the 1.4±0.2 mm/yr rate of global mean sea-level rise for the twentieth century. The Battery, NY tide gauge, located atop crystalline bedrock 26 km to the northwest, recorded a 20th century rate of RSL rise of 3.0±0.3 mm/yr and reflects the regional rate of RSL rise. After global and regional effects are removed from the rate of RSL rise at Sandy Hook, the remaining 0.9±0.5 mm/yr is due to local effects, autocompaction and groundwater extraction induced compaction, within the unconsolidated Cretaceous to recent sediments underlying Sandy Hook. Our previous work showed that 0.13 mm/yr (90% CI 0.01-0.34 mm/yr) is due to autocompaction of young (≤13,350 cal yrs BP), highly compressible, Quaternary sediments underlying Sandy Hook. The remaining 0.8 mm/yr (90% CI 0.3-1.2 mm/yr) is hypothesized to be due to regional and local groundwater extraction. Previous studies have shown that Sandy Hook is within the cone of depression for Monmouth County, NJ. Historical records indicate that pumping for Ft. Hancock, a military installation on Sandy Hook, depleted some shallow aquifers as early as 1905. Visual MODFLOW was used to model the northern portion of the New Jersey coastal plain. Well logs from the northern New Jersey coastal plain were compiled and interpreted to refine subsurface geometries and build the model grid. Well permits provided modern locations and rates of groundwater extraction. 1,794 observation wells were used to calibrate the model. We present model results simulating the change in regional and local groundwater flow and hydraulic pressures from pre-development ( 1880) to present. The pressure changes were then used to calculate the potential changes in thickness of each of the stratigraphic units underneath Sandy Hook between 1880 and

  17. The Hooked Galaxy

    NASA Astrophysics Data System (ADS)

    2006-06-01

    Life is not easy, even for galaxies. Some indeed get so close to their neighbours that they get rather distorted. But such encounters between galaxies have another effect: they spawn new generations of stars, some of which explode. ESO's VLT has obtained a unique vista of a pair of entangled galaxies, in which a star exploded. Because of the importance of exploding stars, and particularly of supernovae of Type Ia [1], for cosmological studies (e.g. relating to claims of an accelerated cosmic expansion and the existence of a new, unknown, constituent of the universe - the so called 'Dark Energy'), they are a preferred target of study for astronomers. Thus, on several occasions, they pointed ESO's Very Large Telescope (VLT) towards a region of the sky that portrays a trio of amazing galaxies. MCG-01-39-003 (bottom right) is a peculiar spiral galaxy, with a telephone number name, that presents a hook at one side, most probably due to the interaction with its neighbour, the spiral galaxy NGC 5917 (upper right). In fact, further enhancement of the image reveals that matter is pulled off MCG-01-39-003 by NGC 5917. Both these galaxies are located at similar distances, about 87 million light-years away, towards the constellation of Libra (The Balance). ESO PR Photo 22/06 ESO PR Photo 22/06 The Hooked Galaxy and its Companion NGC 5917 (also known as Arp 254 and MCG-01-39-002) is about 750 times fainter than can be seen by the unaided eye and is about 40,000 light-years across. It was discovered in 1835 by William Herschel, who strangely enough, seems to have missed its hooked companion, only 2.5 times fainter. As seen at the bottom left of this exceptional VLT image, a still fainter and nameless, but intricately beautiful, barred spiral galaxy looks from a distance the entangled pair, while many 'island universes' perform a cosmic dance in the background. But this is not the reason why astronomers look at this region. Last year, a star exploded in the vicinity of the hook

  18. Estimating Low-Flow Frequency Statistics and Hydrologic Analysis of Selected Streamflow-Gaging Stations, Nooksack River Basin, Northwestern Washington and Canada

    USGS Publications Warehouse

    Curran, Christopher A.; Olsen, Theresa D.

    2009-01-01

    Low-flow frequency statistics were computed at 17 continuous-record streamflow-gaging stations and 8 miscellaneous measurement sites in and near the Nooksack River basin in northwestern Washington and Canada, including the 1, 3, 7, 15, 30, and 60 consecutive-day low flows with recurrence intervals of 2 and 10 years. Using these low-flow statistics, 12 regional regression equations were developed for estimating the same low-flow statistics at ungaged sites in the Nooksack River basin using a weighted-least-squares method. Adjusted R2 (coefficient of determination) values for the equations ranged from 0.79 to 0.93 and the root-mean-squared error (RMSE) expressed as a percentage ranged from 77 to 560 percent. Streamflow records from six gaging stations located in mountain-stream or lowland-stream subbasins of the Nooksack River basin were analyzed to determine if any of the gaging stations could be removed from the network without significant loss of information. Using methods of hydrograph comparison, daily-value correlation, variable space, and flow-duration ratios, and other factors relating to individual subbasins, the six gaging stations were prioritized from most to least important as follows: Skookum Creek (12209490), Anderson Creek (12210900), Warm Creek (12207750), Fishtrap Creek (12212050), Racehorse Creek (12206900), and Clearwater Creek (12207850). The optimum streamflow-gaging station network would contain all gaging stations except Clearwater Creek, and the minimum network would include Skookum Creek and Anderson Creek.

  19. Cost-effectiveness of the US Geological Survey stream-gaging program in Arkansas

    USGS Publications Warehouse

    Darling, M.E.; Lamb, T.E.

    1984-01-01

    This report documents the results of the cost-effectiveness of the stream-gaging program in Arkansas. Data uses and funding sources were identified for the daily-discharge stations. All daily-discharge stations were found to be in one or more data use categories, and none were candidates for alternate methods which would result in discontinuation or conversion to a partial record station. The cost for operation of daily-discharge stations and routing costs to partial record stations, crest gages, pollution control stations as well as seven recording ground-water stations was evaluated in the Kalman-Filtering Cost-Effective Resource allocation (K-CERA) analysis. This operation under current practices requires a budget of $292,150. The average standard error of estimate of streamflow record for the Arkansas District was analyzed at 33 percent.

  20. Hook tool manufacture in New Caledonian crows: behavioural variation and the influence of raw materials.

    PubMed

    Klump, Barbara C; Sugasawa, Shoko; St Clair, James J H; Rutz, Christian

    2015-11-18

    New Caledonian crows use a range of foraging tools, and are the only non-human species known to craft hooks. Based on a small number of observations, their manufacture of hooked stick tools has previously been described as a complex, multi-stage process. Tool behaviour is shaped by genetic predispositions, individual and social learning, and/or ecological influences, but disentangling the relative contributions of these factors remains a major research challenge. The properties of raw materials are an obvious, but largely overlooked, source of variation in tool-manufacture behaviour. We conducted experiments with wild-caught New Caledonian crows, to assess variation in their hooked stick tool making, and to investigate how raw-material properties affect the manufacture process. In Experiment 1, we showed that New Caledonian crows' manufacture of hooked stick tools can be much more variable than previously thought (85 tools by 18 subjects), and can involve two newly-discovered behaviours: 'pulling' for detaching stems and bending of the tool shaft. Crows' tool manufactures varied significantly: in the number of different action types employed; in the time spent processing the hook and bending the tool shaft; and in the structure of processing sequences. In Experiment 2, we examined the interaction of crows with raw materials of different properties, using a novel paradigm that enabled us to determine subjects' rank-ordered preferences (42 tools by 7 subjects). Plant properties influenced: the order in which crows selected stems; whether a hooked tool was manufactured; the time required to release a basic tool; and, possibly, the release technique, the number of behavioural actions, and aspects of processing behaviour. Results from Experiment 2 suggested that at least part of the natural behavioural variation observed in Experiment 1 is due to the effect of raw-material properties. Our discovery of novel manufacture behaviours indicates a plausible scenario for the

  1. Inside Larry's Circle

    ERIC Educational Resources Information Center

    Arnold, Alice

    2009-01-01

    Last spring, students from several North Carolina middle schools were invited to participate in the annual Celebrate the Arts festival in Columbus Country. Larry Hewett, a local art teacher, had been selected to instruct the middle-school students. Larry's River Rock Circles project was made as the starting point for the Celebrate the Arts…

  2. [Case-control study on endobutton plate or clavicular hook plate for the repair of acromioclavicular joint dislocations].

    PubMed

    Zhu, Li; Yang, He-Jie; Zhao, Wan-Jun; Yang, Wu-Min; Zhou, Hui

    2012-02-01

    To compare the treatment results between Endobutton plate and clavicular hook plate for the treatment of acromioclavicular joint dislocations. From January 2009 to September 2010, 30 patients with acromioclavicular joint dislocations were treated with two different fixations: Endobutton plate (15 patients, including 12 males and 3 females, with a mean age of 38.5 +/- 8.2 years) and clavicular hook plate (15 patients, including 14 males and 1 female, with the mean age of 33.8 +/- 5.9 years). The mean operative time and blood loss were compared between the two groups. Joint function was assessed by the Karlsson standard. The mean operative time of the Endobutton group and the hook plate group were (61 +/- 8.6) min and (40 +/- 5.6) min. The average blood loss were (93 +/- 8.4) ml and (100 +/- 12.6) ml. There was no statistical difference between the two groups in the average blood loss and the mean operative time. According to the Karlsson standard, 13 patients got an excellent result, 2 good in the Endobutton group; and 7 patients got an excellent result and 7 good in hook plate group. The therapeutic effect in Endobutton group was better than that of hook plate group. In the treatment of acromioclavicular dislocation, fixation with Endobutton plate is believed to be better than hook plate fixation. It is an effective method for the repair of acromioclavicular joint dislocations in a short term. But its long term effects still need further follow up.

  3. Extremely high myoglobin plasma concentrations producing hook effect in a critically ill patient.

    PubMed

    Kurt-Mangold, Michelle; Drees, Denny; Krasowski, Matthew D

    2012-12-24

    A 21-year old female suffered a cardiac arrest after a one week history of viral illness later shown to be caused by influenza B. The patient required extended cardiopulmonary resuscitation and had further complications including compartment syndrome. Plasma myoglobin concentration was measured using the Roche Diagnostics electrochemiluminescent myoglobin assay. The myoglobin concentration was 205,590 μg/l in an undiluted specimen, consistent with severe rhabdomyolysis. Subsequent myoglobin concentrations measured two days later showed dramatic decreases to approximately 1000 μg/l, raising suspicion of a hook effect. Dilution and re-analysis of the specimens revealed that the actual myoglobin concentrations were >395,000 μg/l, with one specimen possessing an estimated myoglobin concentration of >600,000 μg/l. Interestingly, three specimens from this patient did not show evidence of hook effect, with undiluted specimens producing myoglobin concentrations as high as 284,000 μg/l. Retrospective analysis of myoglobin results over an 8-year period did not reveal other cases with suspicion of hook effect. The case patient had the highest myoglobin concentrations out of 7301 specimens. This case illustrates that while the Roche myoglobin assay has a very wide dynamic range, hook effect can occur with extremely high concentrations of plasma myoglobin. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Design of Gages for Direct Skin Friction Measurements in Complex Turbulent Flows with Shock Impingement Compensation

    DTIC Science & Technology

    2007-06-07

    100 kW/m2 for 0.1 s. Along with the material change, an oil leak problem required a geometric change. Initially, we considered TIG welding or...shear and moment, is addressed through the design, development, and testing of the CF1 and CF2 gages. Chapter 3 presents the evolutionary process ...a shock. Chapter 4 examines the performance of each gage to the nominal load conditions. Through this process , objective 2 is met. The best

  5. Mismanagement and Quality Circles: How Middle Managers Influence Direct Participation.

    ERIC Educational Resources Information Center

    Brennan, Maire

    1991-01-01

    Case studies of five Scottish companies found that four of their quality circles programs had ceased. Essential to the success of quality circles were changes in the systems of reward, communication, and decision making and the cooperation and support of middle managers, who may see quality circles as a threat and who control the resources they…

  6. The operation and maintenance of a crest-stage gaging station

    USGS Publications Warehouse

    Friday, John

    1965-01-01

    Rigid datum controls must be maintained at the gage site throughout the period of record. Physical changes of the site resulting from flood flows or manmade alterations must be evaluated. If a drainage structure such as a culvert is part of the site features, free-flow conditions must be maintained or obstructions carefully documented.

  7. Designing worked examples for learning tangent lines to circles

    NASA Astrophysics Data System (ADS)

    Retnowati, E.; Marissa

    2018-03-01

    Geometry is a branch of mathematics that deals with shape and space, including the circle. A difficult topic in the circle may be the tangent line to circle. This is considered a complex material since students have to simultaneously apply several principles to solve the problems, these are the property of circle, definition of the tangent, measurement and Pythagorean theorem. This paper discusses designs of worked examples for learning tangent line to circles and how to apply this design to an effective and efficient instructional activity. When students do not have sufficient prior knowledge, solving tangent problems might be clumsy, and as a consequence, the problem-solving activity hinders learning. According to a Cognitive Load Theory, learning occurs when students can construct new knowledge based on the relevant knowledge previously learned. When the relevant knowledge is unavailable, providing students with the worked example is suggested. Worked example may reduce unproductive process during learning that causes extraneous cognitive load. Nevertheless, worked examples must be created in such a way facilitate learning.

  8. Algebraic criteria for positive realness relative to the unit circle.

    NASA Technical Reports Server (NTRS)

    Siljak, D. D.

    1973-01-01

    A definition is presented of the circle positive realness of real rational functions relative to the unit circle in the complex variable plane. The problem of testing this kind of positive reality is reduced to the algebraic problem of determining the distribution of zeros of a real polynomial with respect to and on the unit circle. Such reformulation of the problem avoids the search for explicit information about imaginary poles of rational functions. The stated algebraic problem is solved by applying the polynomial criteria of Marden (1966) and Jury (1964), and a completely recursive algorithm for circle positive realness is obtained.

  9. Comparison of the intrusion effects on the maxillary incisors between implant anchorage and J-hook headgear.

    PubMed

    Deguchi, Toru; Murakami, Takashi; Kuroda, Shingo; Yabuuchi, Toshinori; Kamioka, Hiroshi; Takano-Yamamoto, Teruko

    2008-05-01

    Recently, miniscrews have been used to provide anchorage during orthodontic treatment, especially for incisor intrusion. Miniscrews during incisor intrusion are commonly used in implant orthodontics. Traditionally, effective incisor intrusion has been accomplished with J-hook headgear. In this study, we compared the effect of incisor intrusion, force vector, and amount of root resorption between implant orthodontics and J-hook headgear. Lateral cephalometric radiographs from 8 patients in the implant group and 10 patients in the J-hook headgear group were analyzed for incisor retraction. The estimated force vector was analyzed in the horizontal and vertical directions in both groups. Root resorption was also measured on periapical radiographs. In the implant group, significant reductions in overjet, overbite, maxillary incisor to palatal plane, and maxillary incisor to upper lip were observed after intrusion of the incisors. In the J-hook headgear group, significant reductions in overjet, overbite, maxillary incisor to upper lip, and maxillary incisor to SN plane were observed after intrusion of the incisors. There were significantly greater reductions in overbite, maxillary incisor to palatal plane, and maxillary incisor to upper lip in the implant group than in the J-hook headgear group. Estimated force analysis resulted in significantly more force in the vertical direction and less in the horizontal direction in the implant group. Furthermore, significantly less root resorption was observed in the implant group compared with the J-hook headgear group. The maxillary incisors were effectively intruded by using miniscrews as orthodontic anchorage without patient cooperation. The amount of root resorption was not affected by activating the ligature wire from the miniscrew during incisor intrusion.

  10. In vivo analysis of acromioclavicular joint motion after hook plate fixation using three-dimensional computed tomography.

    PubMed

    Kim, Yoon Sang; Yoo, Yon-Sik; Jang, Seong Wook; Nair, Ayyappan Vijayachandran; Jin, Hyonki; Song, Hyun-Seok

    2015-07-01

    The clavicle hook plate can be used to treat acromioclavicular and coracoclavicular ligament injury or distal clavicular fracture with comminution. However, the hook plate can induce subacromial impingement, resulting in discomfort from the hardware. Our inclusion criteria were (1) men and women aged older than 20 years and (2) the presence of comminuted distal clavicular fractures (Neer type IIB) fixed with a hook plate (Synthes, Oberdorf, Switzerland). Three-dimensional computed tomography was obtained before removal of the hook plate. Seven patients were enrolled prospectively. The mean age was 42 years (range, 24-60 years). Zero degree images and abduction images were obtained. The sagittal cut surface was obtained 5 mm medial from the distal clavicle. The equator of the cut surface of the clavicle was compared with the full abduction model to analyze rotation. The center of the cut surface of the clavicle was compared with the full abduction model to analyze translation. The average difference in rotation of the distal clavicle between both shoulders was 16° (range, 3°-22°; P = .001). The mean difference in anterior translation of the distal clavicle was 2.2 mm (range, -0.7 to 5.6 mm; P = .030). Hook plate fixation at the acromioclavicular joint causes decreased internal rotation and increased anterior translation of the distal clavicle with respect to the medial acromion, indicating that the scapula relative to the thorax has decreased posterior tilting and increased external rotation in shoulders fixed using a hook plate. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Circling "the Scourge"

    ERIC Educational Resources Information Center

    Keller, Bess

    2005-01-01

    In Kenya alone, where the infection rate is estimated to have reached 13 percent of the population, 27,000 teachers will die and more than 2 million children will lose one or both parents to AIDS in the next five years. The Kenyan project uses "study circles," in which teachers learn together about HIV, script new sexual behaviors for…

  12. Columbia Smelting & Refining Works Red Hook, Brooklyn, New York

    EPA Pesticide Factsheets

    The site is the former location of a secondary lead smelter called Columbia Smelting and Refining Works (Columbia), and the extent of lead-contaminated soil from the smelter, in the mixed-use neighborhood of Red Hook in Brooklyn, New York. The footprint of

  13. Operational improvements at traffic circles : safety analysis, final report, December 2008.

    DOT National Transportation Integrated Search

    2008-12-01

    The purpose of this study was to improve the safety and operation at three traffic circles in New : Jersey. To do this, data were collected at the traffic circles to allow researchers to model the : circles using the PARAMICS software simulation pack...

  14. A Dual-Range Strain Gage Weighing Transducer Employing Automatic Switching

    Treesearch

    Rodger A. Arola

    1968-01-01

    Describes a dual-range strain gage transducer which has proven to be an excellent weight-sensing device for weighing trees and tree-length logs; discusses basic principals of the design and operation; and shows that a single transducer having two sensitivity ranges with automatic internal switching can sense weight with good repeatability and that one calibration curve...

  15. The Shuttle Orbital Maneuvering System P-V-T Propellant Quantity Gaging Accuracy and Leak Detection Allowance for Four Instrumentation Conditions

    NASA Technical Reports Server (NTRS)

    Duhon, D. D.

    1975-01-01

    The shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module computes the quantity of usable OMS propellant remaining based on the real gas P-V-T relationship for the propellant tank pressurant, helium. The OMS P-V-T propellant quantity gaging error was determined for four sets of instrumentation configurations and accuracies with the propellant tank operating in the normal constant pressure mode and in the blowdown mode. The instrumentation inaccuracy allowance for propellant leak detection was also computed for these same four sets of instrumentation. These gaging errors and leak detection allowances are presented in tables designed to permit a direct comparison of the effectiveness of the four instrumentation sets. The results show the magnitudes of the improvements in propellant quantity gaging accuracies and propellant leak detection allowances which can be achieved by employing more accurate pressure and temperature instrumentation.

  16. Distribution of Circles on a Circle and Correlation Between Vortex Rings of Superfluids

    NASA Astrophysics Data System (ADS)

    Onur Fen, Mehmet; Erkoç, Šakír

    2007-05-01

    Superfluids are characterized by absence of viscosity. When superfluids are rotated, differently from normal fluids, they form more than one vortex in the containers where they are placed. The number of vortices change as the rotation velocity changes, but this change is not linear. M.W. Zwierlein et al. observed the vortices in experiments, observing up to a number of 80. Experiments also showed that the vortex distributions cannot include large spaces. By using experimental data, we noticed that when we think of vortices as vortex rings, their centers are at the same geometric location and these geometric locations are concentric circles. We generalized the distribution of these geometric places and formulized it. Our formula includes the magic circle numbers. When the number of vortices reach these magic numbers, the number of geometric locations increase by 1.

  17. Hook plate fixation for acute acromioclavicular dislocations without coracoclavicular ligament reconstruction: a functional outcome study in military personnel.

    PubMed

    Kumar, Narinder; Sharma, Vyom

    2015-08-01

    The aim of our study was to evaluate the shoulder function after clavicular hook plate fixation of acute acromioclavicular dislocations (Rockwood type III) in a population group consisting exclusively of high-demand military personnel. This prospective study was carried out at a tertiary care military orthopaedic centre during 2012-2013 using clavicular hook plate for management of acromioclavicular injuries without coracoclavicular ligament reconstruction in 33 patients. All patients underwent routine implant removal after 16 weeks. The functional outcome was assessed at 3, 6 and 12 months after hook plate removal and 2 years from the initial surgery using the Constant Murley and UCLA Scores. All the patients were male serving soldiers and had sustained acromioclavicular joint dislocation (Rockwood type III). Mean age of the patient group was 34.24 years (21-55 years). The mean follow-up period in this study was 23.5 months (20-26 months) after hook plate fixation and an average of 19.9 months (17-22 months) after hook plate removal. The average Constant Score at 3 months after hook plate removal was 60.3 as compared to 83.7 and 90.3 at 6 months and 1 year, respectively, and an average of 91.8 at the last follow-up that was approximately 2 years after initial surgery which was statistically significant (p value <0.05). The UCLA Score was an average of 15.27, 25.9 and 30.1 at 3, 6 months and 1 year, respectively, after removal of hook plate which improved further an average of 32.3 at the last follow-up, which was also statistically significant (p value <0.05). Clavicular hook plate fixation without coracoclavicular ligament reconstruction is a good option for acute acromioclavicular dislocations producing excellent medium-term functional results in high-demand soldiers.

  18. Mitigating the Hook Effect in Lateral Flow Sandwich Immunoassays Using Real-Time Reaction Kinetics.

    PubMed

    Rey, Elizabeth G; O'Dell, Dakota; Mehta, Saurabh; Erickson, David

    2017-05-02

    The quantification of analyte concentrations using lateral flow assays is a low-cost and user-friendly alternative to traditional lab-based assays. However, sandwich-type immunoassays are often limited by the high-dose hook effect, which causes falsely low results when analytes are present at very high concentrations. In this paper, we present a reaction kinetics-based technique that solves this problem, significantly increasing the dynamic range of these devices. With the use of a traditional sandwich lateral flow immunoassay, a portable imaging device, and a mobile interface, we demonstrate the technique by quantifying C-reactive protein concentrations in human serum over a large portion of the physiological range. The technique could be applied to any hook effect-limited sandwich lateral flow assay and has a high level of accuracy even in the hook effect range.

  19. Conceptions and Representations: The Circle as an Example.

    ERIC Educational Resources Information Center

    Janvier, Claude

    This paper, which addresses the issue of representation as an internal construct corresponding to an external abstract configuration, attempts to extend A. A. DiSessa's phenomenological primitives to mathematics (particularly to the notion of circle). Various acceptations of the word representation are examined, using the notion of a circle as an…

  20. Cryogenic strain gage techniques used in force balance design for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Ferris, A. T.

    1986-01-01

    A force balance is a strain gage transducer used in wind tunnels to measure the forces and moments on aerodynamic models. Techniques have been established for temperature-compensation of force balances to allow their use over the operating temperature range of a cryogenic wind tunnel (-190C to 60C) without thermal control. This was accomplished by using a patented strain gage matching process to minimize inherent thermal differences, and a thermal compensation procedure to reduce the remaining thermally-induced outputs to acceptable levels. A method of compensating for mechanical movement of the axial force measuring beam caused by thermally-induced stresses under transient temperatures was also included.

  1. The effects of incomplete annealing on the temperature dependence of sheet resistance and gage factor in aluminum and phosphorus implanted silicon on sapphire

    NASA Technical Reports Server (NTRS)

    Pisciotta, B. P.; Gross, C.

    1976-01-01

    Partial annealing of damage to the crystal lattice during ion implantation reduces the temperature coefficient of resistivity of ion-implanted silicon, while facilitating controlled doping. Reliance on this method for temperature compensation of the resistivity and strain-gage factor is discussed. Implantation conditions and annealing conditions are detailed. The gage factor and its temperature variation are not drastically affected by crystal damage for some crystal orientations. A model is proposed to account for the effects of electron damage on the temperature dependence of resistivity and on silicon piezoresistance. The results are applicable to the design of silicon-on-sapphire strain gages with high gage factors.

  2. Feasibility of development of a nuclear density gage for determining the density of plastic concrete at a particular stratum : final report.

    DOT National Transportation Integrated Search

    1981-05-01

    Development of a nuclear density gage for determining the degree of consolidation of plastic concrete in selected horizontal layers was determined to be feasible. A commercially available, with some modifications, two-probe density gage (detector in ...

  3. Cost effectiveness of the US Geological Survey stream-gaging program in Alabama

    USGS Publications Warehouse

    Jeffcoat, H.H.

    1987-01-01

    A study of the cost effectiveness of the stream gaging program in Alabama identified data uses and funding sources for 72 surface water stations (including dam stations, slope stations, and continuous-velocity stations) operated by the U.S. Geological Survey in Alabama with a budget of $393,600. Of these , 58 gaging stations were used in all phases of the analysis at a funding level of $328,380. For the current policy of operation of the 58-station program, the average standard error of estimation of instantaneous discharge is 29.3%. This overall level of accuracy can be maintained with a budget of $319,800 by optimizing routes and implementing some policy changes. The maximum budget considered in the analysis was $361,200, which gave an average standard error of estimation of 20.6%. The minimum budget considered was $299,360, with an average standard error of estimation of 36.5%. The study indicates that a major source of error in the stream gaging records is lost or missing data that are the result of streamside equipment failure. If perfect equipment were available, the standard error in estimating instantaneous discharge under the current program and budget could be reduced to 18.6%. This can also be interpreted to mean that the streamflow data records have a standard error of this magnitude during times when the equipment is operating properly. (Author 's abstract)

  4. Models to support students’ understanding of measuring area of circles

    NASA Astrophysics Data System (ADS)

    Rejeki, S.; Putri, R. I. I.

    2018-01-01

    Many studies showed that enormous students got confused about the concepts of measuring area of circles. The main reason is because mathematics classroom practices emphasized on memorizing formulas rather than understanding concepts. Therefore, in this study, a set of learning activities were designed as an innovation in learning area measurement of circles. The activities involved two models namely grid paper and reshaping which are respectively as a means and a strategy to support students’ learning of area measurement of circles. Design research was used as the research approach to achieve the aim. Thirty-eight of 8th graders in Indonesia were involved in this study. In this study, together with the contextual problems, the grid paper and reshaping sectors, which used as the models in this learning, helped the students to gradually develop their understanding of the area measurement of circles. The grid papers plays important role in comparing and estimating areas. Whereas, the reshaping sectors might support students’ understanding of the circumference and the area measurement of circles. Those two models could be the tool for promoting the informal theory of area measurement. Besides, the whole activities gave important role on distinguishing the area and perimeter of circles.

  5. Astronaut James Newman with latch hook for tether device

    NASA Image and Video Library

    1993-09-19

    STS051-26-002 (12-22 Sept 1993) --- Astronaut James H. Newman, mission specialist, shows off a latch hook for a tether device used during the STS-51 extravehicular activity (EVA) on September 16, 1993. Newman, on Discovery's middeck, appears surrounded by sleep restraints.

  6. Condition assessment of reinforced concrete beams using dynamic data measured with distributed long-gage macro-strain sensors

    NASA Astrophysics Data System (ADS)

    Hong, W.; Wu, Z. S.; Yang, C. Q.; Wan, C. F.; Wu, G.; Zhang, Y. F.

    2012-06-01

    A new condition assessment strategy of reinforced concrete (RC) beams is proposed in this paper. This strategy is based on frequency analysis of the dynamic data measured with distributed long-gage macro-stain sensors. After extracting modal macro-strain, the reference-based damage index is theoretically deducted in which the variations of modal flexural rigidity and modal neutral axis height are considered. The reference-free damage index is also presented for comparison. Both finite element simulation and experiment investigations were carried out to verify the proposed method. The manufacturing procedure of long-gage fiber Bragg grating (FBG) sensor chosen in the experiment is firstly presented, followed by an experimental study on the essential sensing properties of the long-gage macro-strain sensors and the results verify the excellent sensing properties, in particular the measurement accuracy and dynamic measuring capacity. Modal analysis results of a concrete beam show that the damage appearing in the beam can be well identified by the damage index while the vibration testing results of a RC beam show that the proposed method can not only capture small crack initiation but its propagation. It can be concluded that distributed long-gage dynamic macro-strain sensing technique has great potential for the condition assessment of RC structures subjected to dynamic loading.

  7. College Students' Science Societies and Special-Interest Circles

    ERIC Educational Resources Information Center

    Ivanov, A.

    2005-01-01

    From the point of view of their age, student science societies and special-interest circles are among the most venerable forms of corporate association among students in colleges and universities. In this article, the author traces the formation of different societies and special-interest circles by college students in different universities in…

  8. Integrating Literature Circles into a Cotaught Inclusive Classroom

    ERIC Educational Resources Information Center

    Whittaker, Catharine R.

    2012-01-01

    Literature circles or book clubs are small, heterogeneous groups of students who have chosen to read and discuss the same book together. The research on literature circles suggests that they hold great promise for increasing students' enjoyment of reading and honing their literacy skills. When evidence-based strategies are embedded into a…

  9. Introducing Motion in a Circle.

    ERIC Educational Resources Information Center

    Roche, John

    2001-01-01

    Motion in a circle troubled Newton and his contemporaries and troubles students today. Presents a clear presentation of certain aspects, particularly centripetal acceleration and centrifugal force. (Author/MM)

  10. Transaction Circles with Digital Texts as a Foundation for Democratic Practices

    ERIC Educational Resources Information Center

    Brown, Sally

    2015-01-01

    Transaction circles weave together elements of guided reading and literature circles in an open conversational structure that supports students as agentive learners. Discourse within these circles utilizing digital informational texts assist in the development of democratic practices even in a time when federal mandates limit curricula and…

  11. Physiological stress and post-release mortality of white marlin (Kajikia albida) caught in the United States recreational fishery

    PubMed Central

    Schlenker, Lela S.; Latour, Robert J.; Brill, Richard W.; Graves, John E.

    2016-01-01

    White marlin, a highly migratory pelagic marine fish, support important commercial and recreational fisheries throughout their range in the tropical and subtropical Atlantic Ocean. More than 10 000 individuals can be caught annually in the United States recreational fishery, of which the vast majority are captured on circle hooks and released alive. The probability of post-release mortality of white marlin released from circle hooks has been documented to be <0.02, but the associated physiological stress resulting from capture and handling techniques has not been characterized despite its importance for understanding the health of released fish. We examined the physiological response of 68 white marlin caught on circle hooks in the recreational fishery and followed the fate of 22 of these fish with pop-up satellite archival tags programmed to release after 30 days. Measures of plasma sodium, chloride, glucose and lactate concentrations taken from fish that were briefly and consistently (mean = 120 s, standard deviation = 40 s) removed from the water increased with angling time, but post-release mortality was inversely related to angling time. The probability of post-release mortality was predicted by elevated plasma potassium concentrations and was more than 10 times greater than has been previously reported for white marlin caught on circle hooks that were not removed from the water. This disparity in estimates of post-release mortality suggests that removal of fish from the water for physiological sampling greatly heightens stress, disrupts homeostasis and thus increases the probability of post-release mortality. Our results demonstrate that elevated concentrations of plasma potassium predict mortality in white marlin and that the probability of post-release mortality is highly dependent on post-capture handling procedures. PMID:27293745

  12. School Safety in a Post-Sandy Hook World

    ERIC Educational Resources Information Center

    Trump, Kenneth S.

    2014-01-01

    In this report the author, who is a school safety expert, provides information about school safety in a post-Sandy Hook world. He presents the following: (1) Continuum of Threats and Responses; (2) The role social media plays; (3) Reliable Best Practices; (4) Policy and Funding--Climate and Context; (5) Policy and Funding--Things to Avoid; and (6)…

  13. Walking in circles: a modelling approach

    PubMed Central

    Maus, Horst-Moritz; Seyfarth, Andre

    2014-01-01

    Blindfolded or disoriented people have the tendency to walk in circles rather than on a straight line even if they wanted to. Here, we use a minimalistic walking model to examine this phenomenon. The bipedal spring-loaded inverted pendulum exhibits asymptotically stable gaits with centre of mass (CoM) dynamics and ground reaction forces similar to human walking in the sagittal plane. We extend this model into three dimensions, and show that stable walking patterns persist if the leg is aligned with respect to the body (here: CoM velocity) instead of a world reference frame. Further, we demonstrate that asymmetric leg configurations, which are common in humans, will typically lead to walking in circles. The diameter of these circles depends strongly on parameter configuration, but is in line with empirical data from human walkers. Simulation results suggest that walking radius and especially direction of rotation are highly dependent on leg configuration and walking velocity, which explains inconsistent veering behaviour in repeated trials in human data. Finally, we discuss the relation between findings in the model and implications for human walking. PMID:25056215

  14. The "hook effect" causing a negative pregnancy test in a patient with an advanced molar pregnancy.

    PubMed

    Winder, Abigail D; Mora, Adria Suarez; Berry, Emily; Lurain, John R

    2017-08-01

    •At high hCG levels in molar pregnancies, a "hook effect" can cause an artificially negative value.•Delay in diagnosis of a molar pregnancy due to the "hook effect" can lead to severe complications.•Suspicion of a molar pregnancy should be communicated so a diluted sample is used to quantify hCG.

  15. Foreign Language Circles of Knowledge.

    ERIC Educational Resources Information Center

    Schiffer, Deana

    1981-01-01

    Describes use of Circles of Knowledge designed to generate excitement about foreign language learning as technique for individualized instruction. Includes guidelines for using, organizing, and implementing this method. (BK)

  16. Refinement of moisture calibration curves for nuclear gage : interim report no. 1.

    DOT National Transportation Integrated Search

    1972-01-01

    This study was initiated to determine the correct moisture calibration curves for different nuclear gages. It was found that the Troxler Model 227 had a linear response between count ratio and moisture content. Also, the two calibration curves for th...

  17. The discovery of microorganisms by Robert Hooke and Antoni Van Leeuwenhoek, fellows of the Royal Society.

    PubMed

    Gest, Howard

    2004-05-01

    The existence of microscopic organisms was discovered during the period 1665-83 by two Fellows of The Royal Society, Robert Hooke and Antoni van Leeuwenhoek. In Micrographia (1665), Hooke presented the first published depiction of a microganism, the microfungus Mucor. Later, Leeuwenhoek observed and described microscopic protozoa and bacteria. These important revelations were made possible by the ingenuity of Hooke and Leeuwenhoek in fabricating and using simple microscopes that magnified objects from about 25-fold to 250-fold. After a lapse of more than 150 years, microscopy became the backbone of our understanding of the roles of microbes in the causation of infectious diseases and the recycling of chemical elements in the biosphere.

  18. Empirical Evaluation of Different Feature Representations for Social Circles Detection

    DTIC Science & Technology

    2015-06-16

    study and compare the performance on the available labelled Facebook data from the Kaggle competition on learning social circles in networks . We...Kaggle competition on learning social circles in networks [5]. The data consist of hand- labelled friendship egonets from Facebook and a set of 57...16. SECURITY CLASSIFICATION OF: Social circles detection is a special case of community detection in social network that is currently attracting a

  19. Native American Values and Management Education: Envisioning an Inclusive Virtuous Circle

    ERIC Educational Resources Information Center

    Verbos, Amy Klemm; Gladstone, Joe S.; Kennedy, Deanna M.

    2011-01-01

    Circles are symbols of interconnectedness. Behavioral circles can be vicious or virtuous. Many American Indians are caught in a vicious circle of exclusion from the purported benefits of Westernization, entrapment in its negative elements, and the ongoing undermining of their culture and thus their identities. Yet Native Americans, along with many…

  20. Rose Prickles and Asparagus Spines--Different Hook Structures as Attachment Devices in Climbing Plants.

    PubMed

    Gallenmüller, Friederike; Feus, Amélie; Fiedler, Kathrin; Speck, Thomas

    2015-01-01

    Functional morphology and biomechanical properties of hook structures functioning as attachment devices in the leaning climbers Rosa arvensis, Rosa arvensis 'Splendens', Asparagus falcatus and Asparagus setaceus are analysed in order to investigate the variability in closely related species as well as convergent developments of hook structure and properties in distant systematic lineages (monocots and dicots). Prickles and spines were characterised by their size, orientation and the maximum force measured at failure in mechanical tests performed with traction forces applied at different angles. In Rosa arvensis and Rosa arvensis 'Splendens' three types of prickles differing largely in geometrical and mechanical properties are identified (prickles of the wild species and two types of prickles in the cultivar). In prickles of Rosa arvensis no particular orientation of the prickle tip is found whereas in the cultivar Rosa arvensis 'Splendens' prickles gradually gain a downward-orientation due to differential growth in the first weeks of their development. Differences in mechanical properties and modes of failure are correlated to geometrical parameters. In Asparagus falcatus and Asparagus setaceus spines are composed of leaf tissue, stem tissue and tissue of the axillary bud. Between species spines differ in size, orientation, distribution along the stem, tissue contributions and mechanical properties. The prickles of Rosa arvensis and its cultivar and the spines of the studied Asparagus species have several traits in common: (1) a gradual change of cell size and cell wall thickness, with larger cells in the centre and smaller thick-walled cells at the periphery of the hooks, (2) occurrence of a diversity of shape and geometry within one individual, (3) failure of single hooks when submitted to moderate mechanical stresses (Fmax/basal area < 35 N/mm²) and (4) failure of the hooks without severe stem damage (at least in the tested wild species).

  1. COMPLETENESS OF CIRCLE OF WILLIS IN ASYMPTOMATIC AND SYMPTOMATIC EXTRACRANIAL CAROTID DISEASE.

    PubMed

    Manojlovic, Vladimir; Popovic, Vlandan; Nikoloc, Dragan; Milosevic, Dorde; Pasternak, Janko; Budakov, Nebojsa

    2016-11-01

    This research has been aimed at determining whether incomplete Circle of Willis in patients with significant extracranial carotid stenosis is associated with a higher incidence of neurological symptomatology and/or ischemnic cerebral lesions. The research was conducted as a prospective study which comprised 211 patients who underwent surgical treatment of extracranial carotid disease at the Department of Vascular Surgery in Novi Sad and 102 patients in the control group. Each patient underwent preoperative magnetic resonance imaging and magnetic resonance angiography with visualization of cerebral parenchyma. extracranial and intracranial cerebral circulation. Assessment of Circle of Willis morphology was performed by 3D time-of-fight magnetic resonance angiogram sequence analysis. The patients were divided into two groups: group I - the patients with'complete Circle of Willis and group II - the patients with incomplete Circle of Willis i.e. with the disruption of anterior and/ or ipsilateral posterior circulation - regarding the side of signif icant carotid stenosis. Out of 211 patients who -were operated during a two-year period, 133 had the complete Circle of Willis. while 78 patients had the incomplete Circle of Willis. Out of 111 patients with symptomatic carotid disease or silent cerebral infarction, 52.5% (58) had the complete Circle of' Willis and 47.5% (53) had the incomplete Circle of Willis. It was shown to be statistically different (P = 0.0146) in relation with the asymptomatic group of patients (100), where the frequency of the complete Circle of Willis was 75% (75) while the insufficiency of anterior or ipsilateral posterior collateral ization was found in 25% (25). In the control group there were significantly fewer cases of developed collateral flow and the complete Circle of Willis (41%) compared to the operated patients with extracranial carotid stenosis (63%) (P= 0.0003). Incompleteness of Circle of Willis is associated with more frequent

  2. 49 CFR 192.509 - Test requirements for pipelines to operate below 100 p.s.i. (689 kPa) gage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 100 p.s.i. (689 kPa) gage. 192.509 Section 192.509 Transportation Other Regulations Relating to... STANDARDS Test Requirements § 192.509 Test requirements for pipelines to operate below 100 p.s.i. (689 kPa... below 100 p.s.i. (689 kPa) gage must be leak tested in accordance with the following: (a) The test...

  3. 49 CFR 192.509 - Test requirements for pipelines to operate below 100 p.s.i. (689 kPa) gage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 100 p.s.i. (689 kPa) gage. 192.509 Section 192.509 Transportation Other Regulations Relating to... STANDARDS Test Requirements § 192.509 Test requirements for pipelines to operate below 100 p.s.i. (689 kPa... below 100 p.s.i. (689 kPa) gage must be leak tested in accordance with the following: (a) The test...

  4. 49 CFR 192.509 - Test requirements for pipelines to operate below 100 p.s.i. (689 kPa) gage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 100 p.s.i. (689 kPa) gage. 192.509 Section 192.509 Transportation Other Regulations Relating to... STANDARDS Test Requirements § 192.509 Test requirements for pipelines to operate below 100 p.s.i. (689 kPa... below 100 p.s.i. (689 kPa) gage must be leak tested in accordance with the following: (a) The test...

  5. 49 CFR 192.509 - Test requirements for pipelines to operate below 100 p.s.i. (689 kPa) gage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 100 p.s.i. (689 kPa) gage. 192.509 Section 192.509 Transportation Other Regulations Relating to... STANDARDS Test Requirements § 192.509 Test requirements for pipelines to operate below 100 p.s.i. (689 kPa... below 100 p.s.i. (689 kPa) gage must be leak tested in accordance with the following: (a) The test...

  6. Primer-optimized results and trends for circular phasing and other circle-to-circle impulsive coplanar rendezvous

    NASA Astrophysics Data System (ADS)

    Sandrik, Suzannah

    Optimal solutions to the impulsive circular phasing problem, a special class of orbital maneuver in which impulsive thrusts shift a vehicle's orbital position by a specified angle, are found using primer vector theory. The complexities of optimal circular phasing are identified and illustrated using specifically designed Matlab software tools. Information from these new visualizations is applied to explain discrepancies in locally optimal solutions found by previous researchers. Two non-phasing circle-to-circle impulsive rendezvous problems are also examined to show the applicability of the tools developed here to a broader class of problems and to show how optimizing these rendezvous problems differs from the circular phasing case.

  7. The Value of the Math Circle for Gifted Middle School Students

    ERIC Educational Resources Information Center

    Burns, Barbara; Henry, Julie; McCarthy, Dianne; Tripp, Jennifer

    2017-01-01

    Math Circles are designed to allow students to explore mathematics using a problem-solving/inquiry approach. Many of the students attending our Math Circle are mathematically talented and curious. This study examines the perspectives of the students and their families in determining why students attend Math Circle, what they enjoy about Math…

  8. Two-station comparison of peak flows to improve flood-frequency estimates for seven streamflow-gaging stations in the Salmon and Clearwater River Basins, Central Idaho

    USGS Publications Warehouse

    Berenbrock, Charles

    2003-01-01

    Improved flood-frequency estimates for short-term (10 or fewer years of record) streamflow-gaging stations were needed to support instream flow studies by the U.S. Forest Service, which are focused on quantifying water rights necessary to maintain or restore productive fish habitat. Because peak-flow data for short-term gaging stations can be biased by having been collected during an unusually wet, dry, or otherwise unrepresentative period of record, the data may not represent the full range of potential floods at a site. To test whether peak-flow estimates for short-term gaging stations could be improved, the two-station comparison method was used to adjust the logarithmic mean and logarithmic standard deviation of peak flows for seven short-term gaging stations in the Salmon and Clearwater River Basins, central Idaho. Correlation coefficients determined from regression of peak flows for paired short-term and long-term (more than 10 years of record) gaging stations over a concurrent period of record indicated that the mean and standard deviation of peak flows for all short-term gaging stations would be improved. Flood-frequency estimates for seven short-term gaging stations were determined using the adjusted mean and standard deviation. The original (unadjusted) flood-frequency estimates for three of the seven short-term gaging stations differed from the adjusted estimates by less than 10 percent, probably because the data were collected during periods representing the full range of peak flows. Unadjusted flood-frequency estimates for four short-term gaging stations differed from the adjusted estimates by more than 10 percent; unadjusted estimates for Little Slate Creek and Salmon River near Obsidian differed from adjusted estimates by nearly 30 percent. These large differences probably are attributable to unrepresentative periods of peak-flow data collection.

  9. Children with Autism and Peer Group Support: "Using Circles of Friends".

    ERIC Educational Resources Information Center

    Whitaker, Philip; Barratt, Penny; Joy, Helen; Potter, Mo; Thomas, George

    1998-01-01

    Explains the "circle of friends approach" as one strategy aimed at using peer group support to promote the inclusion of children with autism into mainstream schools. It describes use of the approach with six autistic children in years 3 to 10 of British mainstream schools. Evaluation comments by the circle leaders, circle members, and…

  10. Utilizing Photogrammetry and Strain Gage Measurement to Characterize Pressurization of an Inflatable Module

    NASA Technical Reports Server (NTRS)

    Valle, Gerard D.; Selig, Molly; Litteken, Doug; Oliveras, Ovidio

    2012-01-01

    This paper documents the integration of a large hatch penetration into an inflatable module. This paper also documents the comparison of analytical load predictions with measured results utilizing strain measurement. Strain was measured by utilizing photogrammetric measurement and through measurement obtained from strain gages mounted to selected clevises that interface with the structural webbings. Bench testing showed good correlation between strain measurement obtained from an extensometer and photogrammetric measurement especially after the fabric has transitioned through the low load/high strain region of the curve. Test results for the full-scale torus showed mixed results in the lower load and thus lower strain regions. Overall strain, and thus load, measured by strain gages and photogrammetry tracked fairly well with analytical predictions. Methods and areas of improvements are discussed.

  11. A localization algorithm of adaptively determining the ROI of the reference circle in image

    NASA Astrophysics Data System (ADS)

    Xu, Zeen; Zhang, Jun; Zhang, Daimeng; Liu, Xiaomao; Tian, Jinwen

    2018-03-01

    Aiming at solving the problem of accurately positioning the detection probes underwater, this paper proposed a method based on computer vision which can effectively solve this problem. The theory of this method is that: First, because the shape information of the heat tube is similar to a circle in the image, we can find a circle which physical location is well known in the image, we set this circle as the reference circle. Second, we calculate the pixel offset between the reference circle and the probes in the picture, and adjust the steering gear through the offset. As a result, we can accurately measure the physical distance between the probes and the under test heat tubes, then we can know the precise location of the probes underwater. However, how to choose reference circle in image is a difficult problem. In this paper, we propose an algorithm that can adaptively confirm the area of reference circle. In this area, there will be only one circle, and the circle is the reference circle. The test results show that the accuracy of the algorithm of extracting the reference circle in the whole picture without using ROI (region of interest) of the reference circle is only 58.76% and the proposed algorithm is 95.88%. The experimental results indicate that the proposed algorithm can effectively improve the efficiency of the tubes detection.

  12. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  13. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 3 2014-07-01 2014-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  14. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  15. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  16. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  17. Techniques for estimating monthly mean streamflow at gaged sites and monthly streamflow duration characteristics at ungaged sites in central Nevada

    USGS Publications Warehouse

    Hess, G.W.; Bohman, L.R.

    1996-01-01

    Techniques for estimating monthly mean streamflow at gaged sites and monthly streamflow duration characteristics at ungaged sites in central Nevada were developed using streamflow records at six gaged sites and basin physical and climatic characteristics. Streamflow data at gaged sites were related by regression techniques to concurrent flows at nearby gaging stations so that monthly mean streamflows for periods of missing or no record can be estimated for gaged sites in central Nevada. The standard error of estimate for relations at these sites ranged from 12 to 196 percent. Also, monthly streamflow data for selected percent exceedence levels were used in regression analyses with basin and climatic variables to determine relations for ungaged basins for annual and monthly percent exceedence levels. Analyses indicate that the drainage area and percent of drainage area at altitudes greater than 10,000 feet are the most significant variables. For the annual percent exceedence, the standard error of estimate of the relations for ungaged sites ranged from 51 to 96 percent and standard error of prediction for ungaged sites ranged from 96 to 249 percent. For the monthly percent exceedence values, the standard error of estimate of the relations ranged from 31 to 168 percent, and the standard error of prediction ranged from 115 to 3,124 percent. Reliability and limitations of the estimating methods are described.

  18. Quality circles: the nurse executive as mentor.

    PubMed

    Flarey, D L

    1991-12-01

    Changes within and around the health care environment are forcing health care executives to reexamine their managerial and leadership styles to confront the resulting turbulence. The nurse executive is charged with the profound responsibility of directing the delivery of nursing care throughout the organization. Care delivered today must be of high quality. Declining financial resources as well as personnel shortages cause the executive to be an effective innovator in meeting the increasing demands. Quality circles offer the nurse executive an avenue of recourse. Circles have been effectively implemented in the health care setting, as has been consistently documented over time. By way of a participative management approach, quality circles may lead to increased employee morale and productivity, cost savings, and decreased employee turnover rates, as well as realization of socialization and self-actualization needs. A most effective approach to their introduction would be implementation at the first-line manager level. This promotes an acceptance of the concept at the management level as well as a training course for managers to implement the process at the unit level. The nurse executive facilitates the process at the first-line manager level. This facilitation will cause a positive outcome to diffuse throughout the entire organization. Quality circles offer the nurse executive the opportunity to challenge the existing environmental turmoil and effect a positive and lasting change.

  19. Identification of Aroma-active Compounds in Essential Oil from Uncaria Hook by Gas Chromatography- Mass Spectrometry and Gas Chromatography-Olfactometry.

    PubMed

    Iwasa, Megumi; Nakaya, Satoshi; Maki, Yusuke; Marumoto, Shinsuke; Usami, Atsushi; Miyazawa, Mitsuo

    2015-01-01

    The chemical composition of essential oil extracted from Uncaria Hook ("Chotoko" in Japanese), the branch with curved hook of the herbal medicine Uncaria rhynchophylla has been investigated by GC and GC-MS analyses. Eighty-four compounds, representing 90.8% of the total content was identified in oil obtained from Uncaria Hook. The main components i were (E)-cinnamaldehyde (13.4%), α-copaene (8.0%), methyl eugenol (6.8%), δ-cadinene (5.3%), and curcumene (3.6%). The important key aroma-active compounds in the oil were detected by gas chromatography-olfactometry (GC-O) and aroma extract dilution analysis (AEDA), using the flavor dilution (FD) factor to express the odor potency of each compounds. Furthermore, the odor activity value (OAV) has been used as a measure of the relative contribution of each compound to the aroma of the Uncaria Hook oil. The GC-O and AEDA results showed that α-copaene (FD = 4, OAV = 4376), (E)-linalool oxide (FD = 64, OAV = 9.1), and methyl eugenol (FD = 64, OAV = 29) contributed to the woody and spicy odor of Uncaria Hook oil, whereas furfural (FD = 8, OAV = 4808) contributed to its sweet odor. These results warrant further investigations of the application of essential oil from Uncaria Hook in the phytochemical and medicinal fields.

  20. The Circle of Collaboration.

    ERIC Educational Resources Information Center

    Burnham, Jacki; Discher, Stephanie; Ingle, Krista

    This brief paper describes the Circle of Collaboration approach at one elementary school in Utah that is focusing on development of an inclusive school for all students and implementation of a program (Balance Literacy) to enhance students' reading skills. Balance Literacy incorporates phonemic awareness, phonic instruction, fluency, vocabulary,…

  1. Guided Discovery of the Nine-Point Circle Theorem and Its Proof

    ERIC Educational Resources Information Center

    Buchbinder, Orly

    2018-01-01

    The nine-point circle theorem is one of the most beautiful and surprising theorems in Euclidean geometry. It establishes an existence of a circle passing through nine points, all of which are related to a single triangle. This paper describes a set of instructional activities that can help students discover the nine-point circle theorem through…

  2. Gateway National Recreation Area - Sandy Hook Unit : parking management study

    DOT National Transportation Integrated Search

    2003-12-01

    This report describes the Parking Management System (PMS) concept for the Sandy Hook Traveler Information System (TIS). The PMS is an important component of the TIS because it ultimately will be used to determine the open / closed status of the park....

  3. Structural and genetic analysis of a mutant of Rhodobacter sphaeroides WS8 deficient in hook length control.

    PubMed Central

    González-Pedrajo, B; Ballado, T; Campos, A; Sockett, R E; Camarena, L; Dreyfus, G

    1997-01-01

    Motility in the photosynthetic bacterium Rhodobacter sphaeroides is achieved by the unidirectional rotation of a single subpolar flagellum. In this study, transposon mutagenesis was used to obtain nonmotile flagellar mutants from this bacterium. We report here the isolation and characterization of a mutant that shows a polyhook phenotype. Morphological characterization of the mutant was done by electron microscopy. Polyhooks were obtained by shearing and were used to purify the hook protein monomer (FlgE). The apparent molecular mass of the hook protein was 50 kDa. N-terminal amino acid sequencing and comparisons with the hook proteins of other flagellated bacteria indicated that the Rhodobacter hook protein has consensus sequences common to axial flagellar components. A 25-kb fragment from an R. sphaeroides WS8 cosmid library restored wild-type flagellation and motility to the mutant. Using DNA adjacent to the inserted transposon as a probe, we identified a 4.6-kb SalI restriction fragment that contained the gene responsible for the polyhook phenotype. Nucleotide sequence analysis of this region revealed an open reading frame with a deduced amino acid sequence that was 23.4% identical to that of FliK of Salmonella typhimurium, the polypeptide responsible for hook length control in that enteric bacterium. The relevance of a gene homologous to fliK in the uniflagellated bacterium R. sphaeroides is discussed. PMID:9352903

  4. Easing The Calculation Of Bolt-Circle Coordinates

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1995-01-01

    Bolt Circle Calculation (BOLT-CALC) computer program used to reduce significant time consumed in manually computing trigonometry of rectangular Cartesian coordinates of holes in bolt circle as shown on blueprint or drawing. Eliminates risk of computational errors, particularly in cases involving many holes or in cases in which coordinates expressed to many significant digits. Program assists in many practical situations arising in machine shops. Written in BASIC. Also successfully compiled and implemented by use of Microsoft's QuickBasic v4.0.

  5. Transfissural Route Used for Preoperative Localization of Small Pulmonary Lesions with a Short Hook Wire and Suture System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp

    2015-02-15

    PurposeWe retrospectively evaluated the results of the transfissural route for preoperative localization with a short hook wire and suture system for video-assisted thoracoscopic surgery (VATS).MethodsEleven patients with 11 tumors underwent CT-guided transfissural placement of a hook wire before VATS. This route was selected for all patients, because the distance between the tumor and interlobar fissure was much shorter than the required distance traversed using the conventional approach. Complications were evaluated using the National Cancer Institute Common Terminology Criteria for Adverse Events Version 4.0.ResultsThe hook wire was successfully placed using the transfissural route in all but one case. Of these tenmore » successful placements, two tumors needed a second puncture for optimal placement, because the CT scan showed that the first hook wire was not properly placed in the lung. In one patient, we did not attempt replacement after the first placement was incorrect. In ten successful procedures, the mean distance traversed in the parenchyma of the unaffected lung lobe was 27.9 mm. The distance between the pleura and placed hook wire was significantly shorter than the estimated distance between the pleura and hook wire using the conventional route (mean 16.3 vs. 40.9 mm; P = 0.0002). Grade 1 adverse events occurred (11 pneumothoraxes and 4 pulmonary hemorrhages). No grade 2 or higher adverse event was observed.ConclusionsThe transfissural route used for preoperative localization before VATS is useful for selected patients because this route may allow for more limited lung parenchyma resection.« less

  6. Participation and Gender in Circle-Time Situations in Preschool

    ERIC Educational Resources Information Center

    Emilson, Anette; Johansson, Eva

    2013-01-01

    This study sought to investigate participatory values in relation to gender, as expressed in interactions between teachers and children in circle-time situations in Swedish and Norwegian preschools. This paper reports evidence from three research questions: How is children's participation conditioned in circle-time situations? How are…

  7. Quality Circles in Higher Education: Quality, Satisfaction, and Climate.

    ERIC Educational Resources Information Center

    Kay, Carol; Healy, Margaret

    The effect of quality circles at Iowa State University on absenteeism, performance evaluation, perceptions of the organization climate, job satisfaction, and perceived opportunities for professional and personal growth was measured in this study. The process of quality circles is designed to promote job fulfillment and organizational productivity…

  8. Stone circles: form and soil kinematics.

    PubMed

    Hallet, Bernard

    2013-12-13

    Distinct surface patterns are ubiquitous and diverse in soils of polar and alpine regions, where the ground temperature oscillates about 0 degrees C. They constitute some of the most striking examples of clearly visible, abiotic self-organization in nature. This paper outlines the interplay of frost-related physical processes that produce these patterns spontaneously and presents unique data documenting subsurface soil rotational motion and surface displacement spanning 20 years in well-developed circles of soil outlined by gravel ridges. These sorted circles are particularly attractive research targets for a number of reasons that provide focus for this paper: (i) their exceptional geometric regularity captures the attention of any observer; (ii) they are currently forming and evolving, hence the underlying processes can be monitored readily, especially because they are localized near the ground surface on a scale of metres, which facilitates comprehensive characterization; and (iii) a recent, highly successful numerical model of sorted circle development helps to draw attention to particular field observations that can be used to assess the model, its assumptions and parameter choices, and to the considerable potential for synergetic field and modelling studies.

  9. Stone circles: form and soil kinematics.

    PubMed

    Hallet, Bernard

    2013-01-01

    Distinct surface patterns are ubiquitous and diverse in soils of polar and alpine regions, where the ground temperature oscillates about 0°C. They constitute some of the most striking examples of clearly visible, abiotic self-organization in nature. This paper outlines the interplay of frost-related physical processes that produce these patterns spontaneously and presents unique data documenting subsurface soil rotational motion and surface displacement spanning 20 years in well-developed circles of soil outlined by gravel ridges. These sorted circles are particularly attractive research targets for a number of reasons that provide focus for this paper: (i) their exceptional geometric regularity captures the attention of any observer; (ii) they are currently forming and evolving, hence the underlying processes can be monitored readily, especially because they are localized near the ground surface on a scale of metres, which facilitates comprehensive characterization; and (iii) a recent, highly successful numerical model of sorted circle development helps to draw attention to particular field observations that can be used to assess the model, its assumptions and parameter choices, and to the considerable potential for synergetic field and modelling studies.

  10. Strain Gage Loads Calibration Testing with Airbag Support for the Gulfstream III SubsoniC Research Aircraft Testbed (SCRAT)

    NASA Technical Reports Server (NTRS)

    Lokos, William; Miller, Eric; Hudson, Larry; Holguin, Andrew; Neufeld, David; Haraguchi, Ronnie

    2015-01-01

    This paper describes the design and conduct of the strain gage load calibration ground test of the SubsoniC Research Aircraft Testbed, Gulfstream III aircraft, and the subsequent data analysis and its results. The goal of this effort was to create and validate multi-gage load equations for shear force, bending moment, and torque for two wing measurement stations. For some of the testing the aircraft was supported by three air bags in order to isolate the wing structure from extraneous load inputs through the main landing gear. Thirty-two strain gage bridges were installed on the left wing. Hydraulic loads were applied to the wing lower surface through a total of 16 load zones. Some dead weight load cases were applied to the upper wing surface using shot bags. Maximum applied loads reached 54,000 pounds.

  11. Evaluation of a Quartz Bourdon Pressure Gage of Wind Tunnel Mach Number Control System Application

    NASA Technical Reports Server (NTRS)

    Chapin, W. G.

    1986-01-01

    A theoretical and experimental study was undertaken to determine the feasibility of using the National Transonic Facility's high accuracy Mach number measurement system as part of a closed loop Mach number control system. The theoretical and experimental procedures described are applicable to the engineering design of pressure control systems. The results show that the dynamic response characteristics of the NTF Mach number gage (a Ruska DDR-6000 quartz absolute pressure gage) coupled to a typical length of pressure tubing were only marginally acceptable within a limited range of the facility's total pressure envelope and could not be used in the Mach number control system.

  12. Japanese Quality Control Circles.

    ERIC Educational Resources Information Center

    Nishiyama, Kazuo

    In recent years, United States scholars with an interest in international business and organizational communication have begun to notice the success of Japanese "quality control circles." These are small groups, usually composed of seven to ten workers, who are organized at the production levels within most large Japanese factories. A…

  13. Improvement for identification of heterophile antibody interference and AFP hook effect in immunoassays with multiplex suspension bead array system.

    PubMed

    Wang, Yajie; Yu, Jinsheng; Ren, Yuan; Liu, Li; Li, Haowen; Guo, Anchen; Shi, Congning; Fang, Fang; Juehne, Twyla; Yao, Jianer; Yang, Enhuan; Zhou, Xuelei; Kang, Xixiong

    2013-11-15

    A variety of immunoassays including multiplex suspension bead array have been developed for tumor marker detections; however, these assays could be compromised in their sensitivity and specificity by well-known heterophile antibody interference and hook effect. Using Luminex® multiplex suspension bead arrays, we modified protocols with two newly-developed solutions that can identify heterophile antibody interference and AFP hook effect. Effectiveness of the two solutions was assessed in serum samples from patients. Concentrations of 9 tumor markers in heterophile antibody positive samples assayed with Solution A, containing murine monoclonal antibodies and mouse serum, were significantly reduced when compared with those false high signals assayed without Solution A (all p<0.01). With incorporation of Solution H (fluorescent beads linked with AFP antigen), a new strategy for identification of AFP hook effect was established, and with this strategy AFP hook effect was identified effectively in serum samples with very high levels of AFP. Two proprietary solutions improve the identification of heterophile antibody interference and AFP hook effect. With these solutions, multiplex suspension bead arrays provide more reliable testing results in tumor marker detection where complex clinical serum samples are used. © 2013.

  14. Insights into the Functions of M-T Hook Structure in HIV Fusion Inhibitor Using Molecular Modeling.

    PubMed

    Tan, Jianjun; Yuan, Hongling; Li, Chunhua; Zhang, Xiaoyi; Wang, Cunxin

    2016-04-01

    HIV-1 membrane fusion plays an important role in the process that HIV-1 entries host cells. As a treatment strategy targeting HIV-1 entry process, fusion inhibitors have been proposed. Nevertheless, development of a short peptide possessing high anti-HIV potency is considered a daunting challenge. He et al. found that two residues, Met626 and Thr627, located the upstream of the C-terminal heptad repeat of the gp41, formed a unique hook-like structure (M-T hook) that can dramatically improve the binding stability and anti-HIV activity of the inhibitors. In this work, we explored the molecular mechanism why M-T hook structure could improve the anti-HIV activity of inhibitors. Firstly, molecular dynamic simulation was used to obtain information on the time evolution between gp41 and ligands. Secondly, based on the simulations, molecular mechanics Poisson-Boltzmann surface area (MM-PBSA) and molecular mechanics Generalized Born surface area (MM-GBSA) methods were used to calculate the binding free energies. The binding free energy of the ligand with M-T hook was considerably higher than the other without M-T. Further studies showed that the hydrophobic interactions made the dominant contribution to the binding free energy. The numbers of Hydrogen bonds between gp41 and the ligand with M-T hook structure were more than the other. These findings should provide insights into the inhibition mechanism of the short peptide fusion inhibitors and be useful for the rational design of novel fusion inhibitors in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Teachers' Pets II--Circling Carts

    ERIC Educational Resources Information Center

    Gardner, Robert

    1975-01-01

    Describes a demonstration which illustrates that a body moving with constant speed can be accelerating. The students ride in a circle on a cart made with plywood and roller skates and equipped with bubble accelerometers. (MLH)

  16. Semi-rigid single hook localization the best method for localizing ground glass opacities during video-assisted thoracoscopic surgery: re-aerated swine lung experimental and primary clinical results

    PubMed Central

    Zhao, Guang; Sun, Long; Geng, Guojun; Liu, Hongming; Li, Ning; Liu, Suhuan; Hao, Bing

    2017-01-01

    Background The aim of this study was to compare the effects of currently available preoperative localization methods, including semi-rigid single hook-wire, double-thorn hook-wire, and microcoil, in localizing the pulmonary nodules, thus to select the best technology to assist video-assisted thoracoscopic surgery (VATS) for small ground glass opacities (GGO). Methods Preoperative CT-guided localizing techniques including semi-rigid single hook-wire, double-thorn hook-wire and microcoil were used in re-aerated fresh swine lung for location experiments. The advantages and drawbacks of the three positioning technologies were compared, and then the most optimal technique was used in patients with GGO. Technical success and post-operative complications were used as primary endpoints. Results All three localizing techniques were successfully performed in the re-aerated fresh swine lung. The median tractive force of semi-rigid single hook wire, double-thorn hook wire and microcoil were 6.5, 4.85 and 0.2 N, which measured by a spring dynamometer. The wound sizes in the superficial pleura, caused by unplugging the needles, were 2 mm in double-thorn hook wire, 1 mm in semi-rigid single hook and 1 mm in microcoil, respectively. In patients with GGOs, the semi-rigid hook wires localizations were successfully performed, without any complication that need to be intervened. Dislodgement was reported in one patient before VATS. No major complications related to the preoperative hook wire localization and VATS were observed. Conclusions We found from our localization experiments in the swine lung that, among the commonly used three localization methods, semi-rigid hook wire showed the best operability and practicability than double-thorn hook wire and microcoil. Preoperative localization of small pulmonary nodules with single semi-rigid hook wire system shows a high success rate, acceptable utility and especially low dislodgement in VATS. PMID:29312722

  17. Studying Hooke's Law by Using a Pogo Stick

    ERIC Educational Resources Information Center

    Silva, Nicolas

    2011-01-01

    Perhaps the pogo stick was little Robert Hooke's favorite childhood toy, consisting of a stiff spring inserted in a tube fixed at the upper end and connected to a moveable rod at the other. Hand grips and a foot rest are connected to the tube. The idea is to jump on it taking advantage of the force provided by the spring when it is compressed.…

  18. Circles of support and accountability: The characteristics of core members in England and Wales.

    PubMed

    Clarke, Martin; Warwick, Leah; Völlm, Birgit

    2017-04-01

    Circles of support and accountability, or Circles, use community volunteers to help reintegrate sex offenders at risk of reoffending in the community. The aims of this study are to describe the first 275 male sex offenders ('core members') in England and Wales supported by a Circle and to compare those attending the five largest Circles. As part of their monitoring activity, 10 Circles extracted data from case files, anonymised it and submitted it to Circles UK, the national oversight body. Circles have expanded rapidly with 165 (60%) of Circles commencing in the three years 2011-2013 compared with 110 in the nine years 2002-2010. Most core members were referred from the Probation Service (82%). Circles were provided to men with a range of predicted risks of reoffending - from low (26%) to very high (12%). There were some positive changes between the beginning and end of Circles, such as fewer men being unemployed and more living in their own chosen accommodation. Circles have been used to support the reintegration of a wide range of sex offenders. Given their rapid growth and flexibility, consistent recording standards are required across. These standards should be reviewed periodically to ensure all important fields of change are captured, including frequency of attendance, length per session and quality of engagement in the work. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Evaluation of metal-foil strain gages for cryogenic application in magnetic fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freynik, H.S. Jr.; Roach, D.R.; Deis, D.W.

    1977-07-08

    The requirement for the design and construction of large superconducting magnet systems for fusion research has raised a number of new questions regarding the properties of composite superconducting conductors. One of these, the effect of mechanical stress on the current-carrying capacity of Nb/sub 3/Sn, is of major importance in determining the feasibility of constructing large magnets with this material. A typical experiment for determining such data involves the measurement of critical current versus magnetic field while the conductor is being mechanically strained to various degrees. Techniques are well developed for the current and field measurements, but much less so formore » the accurate measurement of strain at liquid-helium temperature in a high magnetic field. A study was made of commercial, metal-foil strain gages for use under these conditions. The information developed can also be applied to the use of strain gages as diagnostic tools in superconducting magnets.« less

  20. Uncertainty Analysis for Angle Calibrations Using Circle Closure

    PubMed Central

    Estler, W. Tyler

    1998-01-01

    We analyze two types of full-circle angle calibrations: a simple closure in which a single set of unknown angular segments is sequentially compared with an unknown reference angle, and a dual closure in which two divided circles are simultaneously calibrated by intercomparison. In each case, the constraint of circle closure provides auxiliary information that (1) enables a complete calibration process without reference to separately calibrated reference artifacts, and (2) serves to reduce measurement uncertainty. We derive closed-form expressions for the combined standard uncertainties of angle calibrations, following guidelines published by the International Organization for Standardization (ISO) and NIST. The analysis includes methods for the quantitative evaluation of the standard uncertainty of small angle measurement using electronic autocollimators, including the effects of calibration uncertainty and air turbulence. PMID:28009359