Sample records for gain uniformity test

  1. Studies of uniformity of 50 μm low-gain avalanche detectors at the Fermilab test beam

    NASA Astrophysics Data System (ADS)

    Apresyan, A.; Xie, S.; Pena, C.; Arcidiacono, R.; Cartiglia, N.; Carulla, M.; Derylo, G.; Ferrero, M.; Flores, D.; Freeman, P.; Galloway, Z.; Ghassemi, A.; Al Ghoul, H.; Gray, L.; Hidalgo, S.; Kamada, S.; Los, S.; Mandurrino, M.; Merlos, A.; Minafra, N.; Pellegrini, G.; Quirion, D.; Ronzhin, A.; Royon, C.; Sadrozinski, H.; Seiden, A.; Sola, V.; Spiropulu, M.; Staiano, A.; Uplegger, L.; Yamamoto, K.; Yamamura, K.

    2018-07-01

    In this paper we report measurements of the uniformity of time resolution, signal amplitude, and charged particle detection efficiency across the sensor surface of low-gain avalanche detectors (LGAD). Comparisons of the performance of sensors with different doping concentrations and different active thicknesses are presented, as well as their temperature dependence and radiation tolerance up to 6 × 1014 n/cm2. Results were obtained at the Fermilab test beam facility using 120 GeV proton beams, and a high precision pixel tracking detector. LGAD sensors manufactured by the Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) were studied. The uniformity of the sensor response in pulse height before irradiation was found to have a 2% spread. The signal detection efficiency and timing resolution in the sensitive areas before irradiation were found to be 100% and 30-40 ps, respectively. A "no-response" area between pads was measured to be about 130 μm for CNM and 170 μm for HPK sensors. After a neutron fluence of 6 × 1014 n/cm2 the CNM sensor exhibits a large gain variation of up to a factor of 2.5 when comparing metalized and non-metalized sensor areas. An irradiated CNM sensor achieved a time resolution of 30 ps for the metalized area and 40 ps for the non-metalized area, while a HPK sensor irradiated to the same fluence achieved a 30 ps time resolution.

  2. A simple uniformity test for ultrasound phased arrays.

    PubMed

    Dudley, Nicholas J; Woolley, Darren J

    2016-09-01

    It is difficult to test phased array ultrasound transducers for non functioning elements. We aimed to modify a widely performed test to improve its ease and effectiveness for these arrays. A paperclip was slowly moved along the transducer array, with the scanner operating in M-mode, imaging at a fundamental frequency with automatic gain and grey scale adjustment disabled. Non-functioning elements are identified by a dark vertical line in the image. The test was repeated several times for each transducer, looking for consistency of results. 2 transducers, with faults already shown by electronic transducer testing, were used to validate the method. 23 transducers in clinical use were tested. The results of the modified test on the 2 faulty transducers agreed closely with electronic transducer testing results. The test indicated faults in 5 of the 23 transducers in clinical use: 3 with a single failed element and 2 with non-uniform sensitivity. 1 transducer with non-uniform sensitivity had undergone lens repair; the new lens was visibly non-uniform in thickness and further testing showed a reduction in depth of penetration and a loss of elevational focus in comparison with a new transducer. The modified test is capable of detecting non-functioning elements. Further work is required to provide a better understanding of more subtle faults. Copyright © 2016 Associazione Italiana di Fisica Medica. All rights reserved.

  3. UNIFORMLY MOST POWERFUL BAYESIAN TESTS

    PubMed Central

    Johnson, Valen E.

    2014-01-01

    Uniformly most powerful tests are statistical hypothesis tests that provide the greatest power against a fixed null hypothesis among all tests of a given size. In this article, the notion of uniformly most powerful tests is extended to the Bayesian setting by defining uniformly most powerful Bayesian tests to be tests that maximize the probability that the Bayes factor, in favor of the alternative hypothesis, exceeds a specified threshold. Like their classical counterpart, uniformly most powerful Bayesian tests are most easily defined in one-parameter exponential family models, although extensions outside of this class are possible. The connection between uniformly most powerful tests and uniformly most powerful Bayesian tests can be used to provide an approximate calibration between p-values and Bayes factors. Finally, issues regarding the strong dependence of resulting Bayes factors and p-values on sample size are discussed. PMID:24659829

  4. Measurement of basic characteristics and gain uniformity of a triple GEM detector

    NASA Astrophysics Data System (ADS)

    Patra, Rajendra Nath; Singaraju, Rama N.; Biswas, Saikat; Ahammed, Zubayer; Nayak, Tapan K.; Viyogi, Yogendra P.

    2017-08-01

    Large area Gas Electron Multiplier (GEM) detectors have been the preferred choice for tracking devices in major nuclear and particle physics experiments. Uniformity over surface of the detector in terms of gain, energy resolution and efficiency is crucial for the optimum performance of these detectors. In the present work, detailed performance study of a 10×10 cm2 triple GEM detector operated using Ar and CO2 gas mixtures in proportions of 70:30 and 90:10, has been made by making a voltage scan of the efficiency with 106Ru-Rh β-source and cosmic rays. The gain and energy resolution of the detector were studied using the X-ray spectrum of 55Fe source. The uniformity of the detector has been investigated by dividing the detector in 7×7 zones and measuring the gain and energy resolution at the centre of each zone. The variations of the gain and energy resolution have been found to be 8.8% and 6.7%, respectively. These studies are essential to characterise GEM detectors before their final use in the experiments.

  5. Image intensifier gain uniformity improvements in sealed tubes by selective scrubbing

    DOEpatents

    Thomas, S.W.

    1995-04-18

    The gain uniformity of sealed microchannel plate image intensifiers (MCPIs) is improved by selectively scrubbing the high gain sections with a controlled bright light source. Using the premise that ions returning to the cathode from the microchannel plate (MCP) damage the cathode and reduce its sensitivity, a HeNe laser beam light source is raster scanned across the cathode of a microchannel plate image intensifier (MCPI) tube. Cathode current is monitored and when it exceeds a preset threshold, the sweep rate is decreased 1000 times, giving 1000 times the exposure to cathode areas with sensitivity greater than the threshold. The threshold is set at the cathode current corresponding to the lowest sensitivity in the active cathode area so that sensitivity of the entire cathode is reduced to this level. This process reduces tube gain by between 10% and 30% in the high gain areas while gain reduction in low gain areas is negligible. 4 figs.

  6. Image intensifier gain uniformity improvements in sealed tubes by selective scrubbing

    DOEpatents

    Thomas, Stanley W.

    1995-01-01

    The gain uniformity of sealed microchannel plate image intensifiers (MCPIs) is improved by selectively scrubbing the high gain sections with a controlled bright light source. Using the premise that ions returning to the cathode from the microchannel plate (MCP) damage the cathode and reduce its sensitivity, a HeNe laser beam light source is raster scanned across the cathode of a microchannel plate image intensifier (MCPI) tube. Cathode current is monitored and when it exceeds a preset threshold, the sweep rate is decreased 1000 times, giving 1000 times the exposure to cathode areas with sensitivity greater than the threshold. The threshold is set at the cathode current corresponding to the lowest sensitivity in the active cathode area so that sensitivity of the entire cathode is reduced to this level. This process reduces tube gain by between 10% and 30% in the high gain areas while gain reduction in low gain areas is negligible.

  7. A novel compensation method for the anode gain non-uniformity of multi-anode photomultiplier tubes

    NASA Astrophysics Data System (ADS)

    Lee, Chan Mi; Kwon, Sun Il; Ko, Guen Bae; Ito, Mikiko; Yoon, Hyun Suk; Lee, Dong Soo; Jong Hong, Seong; Lee, Jae Sung

    2012-01-01

    The position-sensitive multi-anode photomultiplier tube (MA-PMT) is widely used in high-resolution scintillation detectors. However, the anode gain non-uniformity of this device is a limiting factor that degrades the intrinsic performance of the detector module. The aim of this work was to develop a gain compensation method for the MA-PMT and evaluate the resulting enhancement in the performance of the detector. The method employs a circuit that is composed only of resistors and is placed between the MA-PMT and a resistive charge division network (RCN) used for position encoding. The goal of the circuit is to divide the output current from each anode, so the same current flows into the RCN regardless of the anode gain. The current division is controlled by the combination of a fixed-value series resistor with an output impedance that is much larger than the input impedance of the RCN, and a parallel resistor, which detours part of the current to ground. PSpice simulations of the compensation circuit and the RCN were performed to determine optimal values for the compensation resistors when used with Hamamatsu H8500 MA-PMTs. The intrinsic characteristics of a detector module consisting of this MA-PMT and a lutetium-gadolinium-oxyorthosilicate (LGSO) crystal array were tested with and without the gain compensation method. In simulation, the average coefficient of variation and max/min ratio decreased from 15.7% to 2.7% and 2.0 to 1.2, respectively. In the flood map of the LGSO-H8500 detector, the uniformity of the photopeak position for individual crystals and the energy resolution were much improved. The feasibility of the method was shown by applying it to an octagonal prototype positron emission tomography scanner.

  8. Uniformity testing: assessment of a centralized web-based uniformity analysis system.

    PubMed

    Klempa, Meaghan C

    2011-06-01

    Uniformity testing is performed daily to ensure adequate camera performance before clinical use. The aim of this study is to assess the reliability of Beth Israel Deaconess Medical Center's locally built, centralized, Web-based uniformity analysis system by examining the differences between manufacturer and Web-based National Electrical Manufacturers Association integral uniformity calculations measured in the useful field of view (FOV) and the central FOV. Manufacturer and Web-based integral uniformity calculations measured in the useful FOV and the central FOV were recorded over a 30-d period for 4 cameras from 3 different manufacturers. These data were then statistically analyzed. The differences between the uniformity calculations were computed, in addition to the means and the SDs of these differences for each head of each camera. There was a correlation between the manufacturer and Web-based integral uniformity calculations in the useful FOV and the central FOV over the 30-d period. The average differences between the manufacturer and Web-based useful FOV calculations ranged from -0.30 to 0.099, with SD ranging from 0.092 to 0.32. For the central FOV calculations, the average differences ranged from -0.163 to 0.055, with SD ranging from 0.074 to 0.24. Most of the uniformity calculations computed by this centralized Web-based uniformity analysis system are comparable to the manufacturers' calculations, suggesting that this system is reasonably reliable and effective. This finding is important because centralized Web-based uniformity analysis systems are advantageous in that they test camera performance in the same manner regardless of the manufacturer.

  9. Uniform peanut performance test 2017

    USDA-ARS?s Scientific Manuscript database

    The Uniform Peanut Performance Tests (UPPT) are designed to evaluate the commercial potential of advanced breeding peanut lines not formally released. The tests are performed in ten locations across the peanut production belt. In this study, 2 controls and 14 entries were evaluated at 8 locations....

  10. Uniform Peanut Performance Tests 2012

    USDA-ARS?s Scientific Manuscript database

    The Uniform Peanut Performance Tests (UPPT) were established in 1973 through an informal arrangement among cooperating scientists involving seven major peanut-producing states. In 1995, plant material transfer agreements were also accepted among all cooperators in the UPPT. The year 2012 completed...

  11. Testing of next-generation nonlinear calibration based non-uniformity correction techniques using SWIR devices

    NASA Astrophysics Data System (ADS)

    Lovejoy, McKenna R.; Wickert, Mark A.

    2017-05-01

    A known problem with infrared imaging devices is their non-uniformity. This non-uniformity is the result of dark current, amplifier mismatch as well as the individual photo response of the detectors. To improve performance, non-uniformity correction (NUC) techniques are applied. Standard calibration techniques use linear, or piecewise linear models to approximate the non-uniform gain and off set characteristics as well as the nonlinear response. Piecewise linear models perform better than the one and two-point models, but in many cases require storing an unmanageable number of correction coefficients. Most nonlinear NUC algorithms use a second order polynomial to improve performance and allow for a minimal number of stored coefficients. However, advances in technology now make higher order polynomial NUC algorithms feasible. This study comprehensively tests higher order polynomial NUC algorithms targeted at short wave infrared (SWIR) imagers. Using data collected from actual SWIR cameras, the nonlinear techniques and corresponding performance metrics are compared with current linear methods including the standard one and two-point algorithms. Machine learning, including principal component analysis, is explored for identifying and replacing bad pixels. The data sets are analyzed and the impact of hardware implementation is discussed. Average floating point results show 30% less non-uniformity, in post-corrected data, when using a third order polynomial correction algorithm rather than a second order algorithm. To maximize overall performance, a trade off analysis on polynomial order and coefficient precision is performed. Comprehensive testing, across multiple data sets, provides next generation model validation and performance benchmarks for higher order polynomial NUC methods.

  12. Effects of Device on Video Head Impulse Test (vHIT) Gain.

    PubMed

    Janky, Kristen L; Patterson, Jessie N; Shepard, Neil T; Thomas, Megan L A; Honaker, Julie A

    2017-10-01

    Numerous video head impulse test (vHIT) devices are available commercially; however, gain is not calculated uniformly. An evaluation of these devices/algorithms in healthy controls and patients with vestibular loss is necessary for comparing and synthesizing work that utilizes different devices and gain calculations. Using three commercially available vHIT devices/algorithms, the purpose of the present study was to compare: (1) horizontal canal vHIT gain among devices/algorithms in normal control subjects; (2) the effects of age on vHIT gain for each device/algorithm in normal control subjects; and (3) the clinical performance of horizontal canal vHIT gain between devices/algorithms for differentiating normal versus abnormal vestibular function. Prospective. Sixty-one normal control adult subjects (range 20-78) and eleven adults with unilateral or bilateral vestibular loss (range 32-79). vHIT was administered using three different devices/algorithms, randomized in order, for each subject on the same day: (1) Impulse (Otometrics, Schaumberg, IL; monocular eye recording, right eye only; using area under the curve gain), (2) EyeSeeCam (Interacoustics, Denmark; monocular eye recording, left eye only; using instantaneous gain), and (3) VisualEyes (MicroMedical, Chatham, IL, binocular eye recording; using position gain). There was a significant mean difference in vHIT gain among devices/algorithms for both the normal control and vestibular loss groups. vHIT gain was significantly larger in the ipsilateral direction of the eye used to measure gain; however, in spite of the significant mean differences in vHIT gain among devices/algorithms and the significant directional bias, classification of "normal" versus "abnormal" gain is consistent across all compared devices/algorithms, with the exception of instantaneous gain at 40 msec. There was not an effect of age on vHIT gain up to 78 years regardless of the device/algorithm. These findings support that vHIT gain is

  13. Multistage Computerized Adaptive Testing with Uniform Item Exposure

    ERIC Educational Resources Information Center

    Edwards, Michael C.; Flora, David B.; Thissen, David

    2012-01-01

    This article describes a computerized adaptive test (CAT) based on the uniform item exposure multi-form structure (uMFS). The uMFS is a specialization of the multi-form structure (MFS) idea described by Armstrong, Jones, Berliner, and Pashley (1998). In an MFS CAT, the examinee first responds to a small fixed block of items. The items comprising…

  14. Genetic Gains Through Testing and Crossing Longleaf Pine Plus Trees

    Treesearch

    Calvin F. Bey; E. Bayne Snyder

    1978-01-01

    A progeny test of 226 superior tree selections from nine geographic sources across the South confirmed earlier results that showed the Gulf Coast source superior in survival and growth. Family variation within a region was large and provided additional genetic gain. Control-pollinated tests of elite x elite trees yielded even more gains. Progeny of the elite x elite...

  15. An efficient shutter-less non-uniformity correction method for infrared focal plane arrays

    NASA Astrophysics Data System (ADS)

    Huang, Xiyan; Sui, Xiubao; Zhao, Yao

    2017-02-01

    The non-uniformity response in infrared focal plane array (IRFPA) detectors has a bad effect on images with fixed pattern noise. At present, it is common to use shutter to prevent from radiation of target and to update the parameters of non-uniformity correction in the infrared imaging system. The use of shutter causes "freezing" image. And inevitably, there exists the problems of the instability and reliability of system, power consumption, and concealment of infrared detection. In this paper, we present an efficient shutter-less non-uniformity correction (NUC) method for infrared focal plane arrays. The infrared imaging system can use the data gaining in thermostat to calculate the incident infrared radiation by shell real-timely. And the primary output of detector except the shell radiation can be corrected by the gain coefficient. This method has been tested in real infrared imaging system, reaching high correction level, reducing fixed pattern noise, adapting wide temperature range.

  16. Tensile testing grips ensure uniform loading of bimetal tubing specimens

    NASA Technical Reports Server (NTRS)

    Driscol, S. D.; Hunt, V.

    1968-01-01

    Tensile testing grip uniformly distributes stresses to the internal and external tube of bimetal tubing specimens. The grip is comprised of a slotted external tube grip, a slotted internal tube grip, a machine bolt and nut, an internal grip expansion cone, and an external grip compression nut.

  17. Comparison of Video Head Impulse Test (vHIT) Gains Between Two Commercially Available Devices and by Different Gain Analytical Methods.

    PubMed

    Lee, Sang Hun; Yoo, Myung Hoon; Park, Jun Woo; Kang, Byung Chul; Yang, Chan Joo; Kang, Woo Suk; Ahn, Joong Ho; Chung, Jong Woo; Park, Hong Ju

    2018-06-01

    To evaluate whether video head impulse test (vHIT) gains are dependent on the measuring device and method of analysis. Prospective study. vHIT was performed in 25 healthy subjects using two devices simultaneously. vHIT gains were compared between these instruments and using five different methods of comparing position and velocity gains during head movement intervals. The two devices produced different vHIT gain results with the same method of analysis. There were also significant differences in the vHIT gains measured using different analytical methods. The gain analytic method that compares the areas under the velocity curve (AUC) of the head and eye movements during head movements showed lower vHIT gains than a method that compared the peak velocities of the head and eye movements. The former method produced the vHIT gain with the smallest standard deviation among the five procedures tested in this study. vHIT gains differ in normal subjects depending on the device and method of analysis used, suggesting that it is advisable for each device to have its own normal values. Gain calculations that compare the AUC of the head and eye movements during the head movements show the smallest variance.

  18. High-Stakes Testing Hasn't Brought Education Gains

    ERIC Educational Resources Information Center

    Dianis, Judith Browne; Jackson, John H.; Noguera, Pedro

    2015-01-01

    The only thing that more testing will tell us is what we already know: The schools that disadvantaged children attend are not being given the supports necessary to produce achievement gains. Students cannot be tested out of poverty, and while NCLB did take us a step forward by requiring schools to produce evidence that students were learning, it…

  19. Hearing gain with a BAHA test-band in patients with single-sided deafness.

    PubMed

    Kim, Do-Youn; Kim, Tae Su; Shim, Byoung Soo; Jin, In Suk; Ahn, Joong Ho; Chung, Jong Woo; Yoon, Tae Hyun; Park, Hong Ju

    2014-01-01

    It is assumed that preoperative use of a bone-anchored hearing aid (BAHA) test-band will give a patient lower gain compared to real post-operative gain because of the reduction of energy through the scalp when using a test-band. Hearing gains using a BAHA test-band were analyzed in patients with unilateral hearing loss. Nineteen patients with unilateral sensorineural hearing loss were enrolled. A test-band, which was connected to BAHA Intenso with full-on gain, was put on the mastoid. Conventional air-conduction (AC) pure-tone averages (PTAs) and sound-field PTAs and speech reception thresholds (SRTs) were obtained in conditions A (the better ear naked), B (the better ear plugged), and C (the better ear plugged with a test-band on the poorer mastoid). Air-conduction PTAs of the poorer and better ears were 91 ± 19 and 18 ± 8 dB HL. Sound-field PTAs in condition B were higher than those in condition A (54 vs. 26 dB HL), which means that earplugs can block the sound grossly up to 54 dB HL through the better ears. The aided PTAs (24 ± 6 dB HL) in condition C were similar to those of the better ears in condition A (26±9 dB HL), though condition C showed higher thresholds at 500 Hz and lower thresholds at 1 and 2kHz when compared to condition A. The hearing thresholds using a test-band were similar to the published results of BAHA users with the volume to most comfortable level (MCL). Our findings showed that a BAHA test-band on the poorer ear could transmit sound to the cochlea as much as the better ears can hear. The increased functional gain at 1 and 2kHz reflects the technical characteristics of BAHA processor. The reduction of energy through the scalp when using a test-band seems to be offset by the difference of output by setting the volume to full-on gain and using a high-powered speech processor. Preoperative hearing gains using a test-band with full-on gain seems to be similar to the post-operative gains of BAHA users with the volume to MCL. © 2013.

  20. Comparison of Uniform Flux and Uniform Head Wellbore Boundary for the Multilevel Slug Test

    NASA Astrophysics Data System (ADS)

    Chen, C.

    2012-12-01

    The multilevel slug test (MLST) is useful in characterizing the vertical distribution of hydraulic conductivity K(z) around a well. Most MLST models assume a uniform flux (UF) distribution along the screen length ls during the test. This assumption leads to a nonuniform head distribution along ls, which is of question under the field conditions. To this end, the head distribution along ls is assumed to be uniform (UH). The MLST model associated with the UH assumption is mathematically more complicated and thus is less used. The difference of using UF and UH in modeling the MLST is investigated here for confined aquifers. For the low-K conditions of monotonic recovery of well water level, it is found that the well water level recovery predicted by the UH model is faster than that predicted by the UF model, and the discrepancy is more pronounced for a larger aspect ratio of rw/ls with rw being the well radius, a smaller partial penetration ratio of ls/b with b being aquifer thickness, and/or a smaller anisotropy ratio of Kz/Kr. For the high-K condition where oscillatory well water level recovery is oscillatory about its initial position, it is found that amplitude of the oscillatory recovery predicted by the UH model is larger than that by the UF model, and the discrepancy gets larger for a larger aspect ratio, a smaller partial penetration ratio, or a smaller anisotropy ratio. For the fully penetrating condition, both the UH and UF models give the same results, regardless of low- or high-K conditions. For the same set of data, the K value estimated by the UH model will be greater than that by the UF model.

  1. Impact of Uniform Methods on Interlaboratory Antibody Titration Variability: Antibody Titration and Uniform Methods.

    PubMed

    Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H

    2017-01-01

    -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.

  2. Do Gains in Test Scores Explain Labor Market Outcomes?

    ERIC Educational Resources Information Center

    Rose, Heather

    2006-01-01

    Using data from the National Education Longitudinal Study of 1988, this article investigates whether students who made relatively large test score gains during high school had larger earnings 7 years after high school compared to students whose scores improved little. In models that control for pre-high school test scores, family background, and…

  3. 10 CFR 431.204 - Uniform test method for the measurement of energy consumption of illuminated exit signs.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy consumption of illuminated exit signs. 431.204 Section 431.204 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION... Procedures § 431.204 Uniform test method for the measurement of energy consumption of illuminated exit signs...

  4. Static Scene Statistical Non-Uniformity Correction

    DTIC Science & Technology

    2015-03-01

    Error NUC Non-Uniformity Correction RMSE Root Mean Squared Error RSD Relative Standard Deviation S3NUC Static Scene Statistical Non-Uniformity...Deviation ( RSD ) which normalizes the standard deviation, σ, to the mean estimated value, µ using the equation RS D = σ µ × 100. The RSD plot of the gain...estimates is shown in Figure 4.1(b). The RSD plot shows that after a sample size of approximately 10, the different photocount values and the inclusion

  5. 10 CFR Appendix B to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Freezers

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Energy Consumption... ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. B Appendix B to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Freezers The provisions...

  6. 10 CFR Appendix B to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Freezers

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption... ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. B Appendix B to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Freezers The provisions...

  7. 10 CFR Appendix B to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Freezers

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption... ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. B Appendix B to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Freezers The provisions...

  8. Gas electron multiplier (GEM) foil test, repair and effective gain calculation

    NASA Astrophysics Data System (ADS)

    Tahir, Muhammad; Zubair, Muhammad; Khan, Tufail A.; Khan, Ashfaq; Malook, Asad

    2018-06-01

    The focus of my research is based on the gas electron multiplier (GEM) foil test, repairing and effective gain calculation of GEM detector. During my research work define procedure of GEM foil testing short-circuit, detection short-circuits in the foil. Study different ways to remove the short circuits in the foils. Set and define the GEM foil testing procedures in the open air, and with nitrogen gas. Measure the leakage current of the foil and applying different voltages with specified step size. Define the Quality Control (QC) tests and different components of GEM detectors before assembly. Calculate the effective gain of GEM detectors using 109Cd and 55Fe radioactive source.

  9. 10 CFR Appendix A to Subpart K of... - Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Uniform Test Method is used to test more than one unit of a basic model to determine the efficiency of... one ampere and the test current is limited to 15 percent of the winding current. Connect the... 10 Energy 3 2014-01-01 2014-01-01 false Uniform Test Method for Measuring the Energy Consumption...

  10. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. [Reserved] 431.107 Section 431.107 Energy DEPARTMENT OF....107 Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters...

  11. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. [Reserved] 431.107 Section 431.107 Energy DEPARTMENT OF....107 Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters...

  12. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. [Reserved] 431.107 Section 431.107 Energy DEPARTMENT OF....107 Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters...

  13. 10 CFR Appendix D to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption... CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. D Appendix D to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Clothes...

  14. 10 CFR Appendix D to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform Test Method for Measuring the Energy Consumption... CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. D Appendix D to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Clothes...

  15. 10 CFR Appendix D to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Energy Consumption... CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. D Appendix D to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Clothes...

  16. 10 CFR Appendix E to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Water Heaters

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption of Water Heaters E Appendix E to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. E Appendix E to Subpart B of Part 430—Uniform Test Method...

  17. Test plane uniformity analysis for the MSFC solar simulator lamp array

    NASA Technical Reports Server (NTRS)

    Griner, D. B.

    1976-01-01

    A preliminary analysis was made on the solar simulator lamp array. It is an array of 405 tungsten halogen lamps with Fresnel lenses to achieve the required spectral distribution and collimation. A computer program was developed to analyze lamp array performance at the test plane. Measurements were made on individual lamp lens combinations to obtain data for the computer analysis. The analysis indicated that the performance of the lamp array was about as expected, except for a need to position the test plane within 2.7 m of the lamp array to achieve the desired 7 percent uniformity of illumination tolerance.

  18. Propulsion and Energetics Panel Working Group 15 on the Uniform Engine Test Programme

    DTIC Science & Technology

    1990-02-01

    earlier test of uniform aerodynamic models in wind tunnels under the auspices of the Fluid Dynamics Panel. A formal proposal was presented to the...this major new effort and members of the engine test community throughout AGARD were selected to serve on Working Group 15 along with PEP...STPA/MO 4 Mr J.R.Bednarsk; 4 Avenue de Ia Porte d’lssy PE-63 75015 Paris Naval Air Propulsion Center PO Box 7176 GERMANY Trenton. New Jersey 08628

  19. Non-Uniformity Correction Using Nonlinear Characteristic Performance Curves for Calibration

    NASA Astrophysics Data System (ADS)

    Lovejoy, McKenna Roberts

    Infrared imaging is an expansive field with many applications. Advances in infrared technology have lead to a greater demand from both commercial and military sectors. However, a known problem with infrared imaging is its non-uniformity. This non-uniformity stems from the fact that each pixel in an infrared focal plane array has its own photoresponse. Many factors such as exposure time, temperature, and amplifier choice affect how the pixels respond to incoming illumination and thus impact image uniformity. To improve performance non-uniformity correction (NUC) techniques are applied. Standard calibration based techniques commonly use a linear model to approximate the nonlinear response. This often leaves unacceptable levels of residual non-uniformity. Calibration techniques often have to be repeated during use to continually correct the image. In this dissertation alternates to linear NUC algorithms are investigated. The goal of this dissertation is to determine and compare nonlinear non-uniformity correction algorithms. Ideally the results will provide better NUC performance resulting in less residual non-uniformity as well as reduce the need for recalibration. This dissertation will consider new approaches to nonlinear NUC such as higher order polynomials and exponentials. More specifically, a new gain equalization algorithm has been developed. The various nonlinear non-uniformity correction algorithms will be compared with common linear non-uniformity correction algorithms. Performance will be compared based on RMS errors, residual non-uniformity, and the impact quantization has on correction. Performance will be improved by identifying and replacing bad pixels prior to correction. Two bad pixel identification and replacement techniques will be investigated and compared. Performance will be presented in the form of simulation results as well as before and after images taken with short wave infrared cameras. The initial results show, using a third order

  20. 10 CFR Appendix D1 to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption... Appendix D1 to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Clothes... without heated or unheated forced air circulation to remove moisture from the clothing, remove wrinkles or...

  1. 10 CFR Appendix D2 to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform Test Method for Measuring the Energy Consumption... Appendix D2 to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Clothes... forced air circulation to remove moisture from the clothing, remove wrinkles or prevent wrinkling of the...

  2. 10 CFR Appendix D1 to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Energy Consumption... Appendix D1 to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Clothes... without heated or unheated forced air circulation to remove moisture from the clothing, remove wrinkles or...

  3. Liquid-Crystal Display (LCD) Screen Thermal Testing to Simulate Solar Gain

    DTIC Science & Technology

    2015-12-01

    Display (LCD) Screen Thermal Testing to Simulate Solar Gain 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6 . AUTHOR(S) Steven...Sunlight, Monitor Screen Covered 9 2.6 Test 6 – Bench Test with a 250 W Heat Lamp and Hot Mirror Glass 9 2.7 Test 7 – Bench Test with a 250 W Heat...that was used. The use of a black background with white text was important in creating the worst-case scenario for the absorption of solar radiation

  4. The Influence of an NCLB Accountability Plan on the Distribution of Student Test Score Gains

    ERIC Educational Resources Information Center

    Springer, Matthew G.

    2008-01-01

    Previous research on the effect of accountability programs on the distribution of student test score gains is decidedly mixed. This study examines the issue by estimating an educational production function in which test score gains are a function of the incentives schools have to focus instruction on below-proficient students. NCLB's threat of…

  5. Propagating modes in gain-guided optical fibers.

    PubMed

    Siegman, A E

    2003-08-01

    Optical fibers in which gain-guiding effects are significant or even dominant compared with conventional index guiding may become of practical interest for future high-power single-mode fiber lasers. I derive the propagation characteristics of symmetrical slab waveguides and cylindrical optical fibers having arbitrary amounts of mixed gain and index guiding, assuming a single uniform transverse profile for both the gain and the refractive-index steps. Optical fibers of this type are best characterized by using a complex-valued v-squared parameter in place of the real-valued v parameter commonly used to describe conventional index-guided optical fibers.

  6. 10 CFR Appendix S to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads S Appendix S to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. S Appendix S to Subpart B of Part 430—Uniform...

  7. 10 CFR Appendix S to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads S Appendix S to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. S Appendix S to Subpart B of Part 430—Uniform...

  8. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... energy consumption for primary electric heaters. For primary electric heaters, calculate the annual...

  9. GD SDR Automatic Gain Control Characterization Testing

    NASA Technical Reports Server (NTRS)

    Nappier, Jennifer M.; Briones, Janette C.

    2013-01-01

    The General Dynamics (GD) S-Band software defined radio (SDR) in the Space Communications and Navigation (SCAN) Testbed on the International Space Station (ISS) will provide experimenters an opportunity to develop and demonstrate experimental waveforms in space. The GD SDR platform and initial waveform were characterized on the ground before launch and the data will be compared to the data that will be collected during on-orbit operations. A desired function of the SDR is to estimate the received signal to noise ratio (SNR), which would enable experimenters to better determine on-orbit link conditions. The GD SDR does not have an SNR estimator, but it does have an analog and a digital automatic gain control (AGC). The AGCs can be used to estimate the SDR input power which can be converted into a SNR. Tests were conducted to characterize the AGC response to changes in SDR input power and temperature. This purpose of this paper is to describe the tests that were conducted, discuss the results showi ng how the AGCs relate to the SDR input power, and provide recommendations for AGC testing and characterization.

  10. GD SDR Automatic Gain Control Characterization Testing

    NASA Technical Reports Server (NTRS)

    Nappier, Jennifer M.; Briones, Janette C.

    2013-01-01

    The General Dynamics (GD) S-Band software defined radio (SDR) in the Space Communications and Navigation (SCAN) Testbed on the International Space Station (ISS) will provide experimenters an opportunity to develop and demonstrate experimental waveforms in space. The GD SDR platform and initial waveform were characterized on the ground before launch and the data will be compared to the data that will be collected during on-orbit operations. A desired function of the SDR is to estimate the received signal to noise ratio (SNR), which would enable experimenters to better determine on-orbit link conditions. The GD SDR does not have an SNR estimator, but it does have an analog and a digital automatic gain control (AGC). The AGCs can be used to estimate the SDR input power which can be converted into a SNR. Tests were conducted to characterize the AGC response to changes in SDR input power and temperature. This purpose of this paper is to describe the tests that were conducted, discuss the results showing how the AGCs relate to the SDR input power, and provide recommendations for AGC testing and characterization.

  11. 10 CFR Appendix A1 to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Electric Refrigerators and Electric...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Energy Consumption... Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. A1 Appendix A1 to Subpart B of Part 430—Uniform Test Method for Measuring...

  12. 10 CFR Appendix A1 to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Electric Refrigerators and Electric...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption... Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. A1 Appendix A1 to Subpart B of Part 430—Uniform Test Method for Measuring...

  13. Situational Effects May Account for Gain Scores in Cognitive Ability Testing: A Longitudinal SEM Approach

    ERIC Educational Resources Information Center

    Matton, Nadine; Vautier, Stephane; Raufaste, Eric

    2009-01-01

    Mean gain scores for cognitive ability tests between two sessions in a selection setting are now a robust finding, yet not fully understood. Many authors do not attribute such gain scores to an increase in the target abilities. Our approach consists of testing a longitudinal SEM model suitable to this view. We propose to model the scores' changes…

  14. Determining irrigation distribution uniformity and efficiency for nurseries

    Treesearch

    R. Thomas Fernandez

    2010-01-01

    A simple method for testing the distribution uniformity of overhead irrigation systems is described. The procedure is described step-by-step along with an example. Other uses of distribution uniformity testing are presented, as well as common situations that affect distribution uniformity and how to alleviate them.

  15. Quasi-Uniform High Speed Foam Crush Testing Using a Guided Drop Mass Impact

    NASA Technical Reports Server (NTRS)

    Jones, Lisa E. (Technical Monitor); Kellas, Sotiris

    2004-01-01

    A relatively simple method for measuring the dynamic crush response of foam materials at various loading rates is described. The method utilizes a drop mass impact configuration with mass and impact velocity selected such that the crush speed remains approximately uniform during the entire sample crushing event. Instrumentation, data acquisition, and data processing techniques are presented, and limitations of the test method are discussed. The objective of the test method is to produce input data for dynamic finite element modeling involving crash and energy absorption characteristics of foam materials.

  16. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment G Appendix G to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  17. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment G Appendix G to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  18. 10 CFR Appendix O to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Vented Home Heating Equipment

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption..., App. O Appendix O to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... condition. 1.9“Flue gases” means reaction products resulting from the combustion of a fuel with the oxygen...

  19. 10 CFR Appendix O to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Vented Home Heating Equipment

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform Test Method for Measuring the Energy Consumption..., App. O Appendix O to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... mode energy consumption, (i.e., sections 3.7 and 4.7 of this appendix) need not be performed to...

  20. 10 CFR Appendix O to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Vented Home Heating Equipment

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Energy Consumption..., App. O Appendix O to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... products resulting from the combustion of a fuel with the oxygen of the air, including the inerts and any...

  1. 10 CFR Appendix O to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Vented Home Heating Equipment

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption..., App. O Appendix O to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... condition. 1.9“Flue gases” means reaction products resulting from the combustion of a fuel with the oxygen...

  2. 10 CFR Appendix O to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Vented Home Heating Equipment

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption..., App. O Appendix O to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... condition. 1.9“Flue gases” means reaction products resulting from the combustion of a fuel with the oxygen...

  3. Vestibulo-ocular reflex gain values in the suppression head impulse test of healthy subjects.

    PubMed

    Rey-Martinez, Jorge; Thomas-Arrizabalaga, Izaskun; Espinosa-Sanchez, Juan Manuel; Batuecas-Caletrio, Angel; Trinidad-Ruiz, Gabriel; Matiño-Soler, Eusebi; Perez-Fernandez, Nicolas

    2018-02-15

    To assess whether there are differences in vestibulo-ocular reflex (VOR) gain for suppression head impulse (SHIMP) and head impulse (HIMP) video head impulse test paradigms, and if so, what are their causes. Prospective multicenter observational double-blind nonrandomized clinical study was performed by collecting 80 healthy subjects from four reference hospitals. SHIMP data was postprocessed to eliminate impulses in which early SHIMP saccades were detected. Differences between HIMP and SHIMP VOR gain values were statistically evaluated. Head impulse maximum velocity, gender, age, direction of impulse, and hospital center were considered as possible influential factors. A small significant statistical difference between HIMP and SHIMP VOR gain values was found on repeated measures analysis of variance (-0.05 ± 0.006, P < 0.001). Optimized linear model showed a significant influence of age variable on the observed differences for HIMP and SHIMP gain values and did not find influence between gain values differences and maximum head impulse velocity. Both HIMP and SHIMP VOR gain values were significant lower (-0.09, P < 0.001) when the impulses were performed to the left side. We had observed a difference in SHIMP and HIMP gain values not adequately explained by known gain modification factors. The persistence of this slight but significant difference indicates that there are more factors causing lower SHIMP VOR gain values. This difference must to be considered in further studies as well as in the clinical SHIMP testing protocols. We hypothesized that VOR phasic response inhibition could be the underlying cause of this difference. IIb. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Theory and Simulation of Gain-Guided Noncollinear Modes in Chirped Quasi-Phase-Matched Optical Parametric Amplifiers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charbonneau-Lefort, Mathieu; Afeyan, Bedros; Fejer, Martin

    Chirped quasi-phase-matched (QPM) gratings offer essentially constant gain over wide bandwidths, making them promising candidates for short-pulse optical parametric amplifiers. However, experiments have shown that high-gain non-collinear processes exist in spite of the dephasing caused by the non-uniformity of the QPM grating and compete with the desired collinear broadband gain of the amplifier. In this paper, these non-collinear gain-guided modes are investigated numerically and analytically in a model that includes longitudinal non-uniformity of the phase-matching profile, lateral localization of the pump beam and non-collinear propagation of the interacting waves.

  5. Uniform Test Assembly

    ERIC Educational Resources Information Center

    Belov, Dmitry I.

    2008-01-01

    In educational practice, a test assembly problem is formulated as a system of inequalities induced by test specifications. Each solution to the system is a test, represented by a 0-1 vector, where each element corresponds to an item included (1) or not included (0) into the test. Therefore, the size of a 0-1 vector equals the number of items "n"…

  6. 34 CFR 462.41 - How must tests be administered in order to accurately measure educational gain?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... identified in its State's assessment policy. (c) Post-test. A local eligible provider must— (1) Administer a post-test to measure a student's educational functioning level after a set time period or number of instructional hours; (2) Administer the post-test to students at a uniform time, according to its State's...

  7. 34 CFR 462.41 - How must tests be administered in order to accurately measure educational gain?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... identified in its State's assessment policy. (c) Post-test. A local eligible provider must— (1) Administer a post-test to measure a student's educational functioning level after a set time period or number of instructional hours; (2) Administer the post-test to students at a uniform time, according to its State's...

  8. 34 CFR 462.41 - How must tests be administered in order to accurately measure educational gain?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... identified in its State's assessment policy. (c) Post-test. A local eligible provider must— (1) Administer a post-test to measure a student's educational functioning level after a set time period or number of instructional hours; (2) Administer the post-test to students at a uniform time, according to its State's...

  9. 34 CFR 462.41 - How must tests be administered in order to accurately measure educational gain?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... identified in its State's assessment policy. (c) Post-test. A local eligible provider must— (1) Administer a post-test to measure a student's educational functioning level after a set time period or number of instructional hours; (2) Administer the post-test to students at a uniform time, according to its State's...

  10. 34 CFR 462.41 - How must tests be administered in order to accurately measure educational gain?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... identified in its State's assessment policy. (c) Post-test. A local eligible provider must— (1) Administer a post-test to measure a student's educational functioning level after a set time period or number of instructional hours; (2) Administer the post-test to students at a uniform time, according to its State's...

  11. Accelerated Desensitization and Adaptive Attitudes Interventions and Test Gains with Academic Probation Students

    ERIC Educational Resources Information Center

    Driscoll, Richard; Holt, Bruce; Hunter, Lori

    2005-01-01

    The study evaluates the test-gain benefits of an accelerated desensitization and adaptive attitudes intervention for test-anxious students. College students were screened for high test anxiety. Twenty anxious students, half of them on academic probation, were assigned to an Intervention or to a minimal treatment Control group. The Intervention was…

  12. 10 CFR 431.294 - Uniform test method for the measurement of energy consumption of refrigerated bottled or canned...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... consumption of refrigerated bottled or canned beverage vending machines. 431.294 Section 431.294 Energy... EQUIPMENT Refrigerated Bottled or Canned Beverage Vending Machines Test Procedures § 431.294 Uniform test... machines. (a) Scope. This section provides test procedures for measuring, pursuant to EPCA, the energy...

  13. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  14. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  15. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  16. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  17. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals T Appendix T to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. T Appendix T to Subpart B of Part 430—Uniform...

  18. Effects of Response Task and Accessory Stimuli on Redundancy Gain: Tests of the Hemispheric Coactivation Model

    ERIC Educational Resources Information Center

    Miller, Jeff; Van Nes, Fenna

    2007-01-01

    Two experiments tested predictions of the hemispheric coactivation model for redundancy gain (J. O. Miller, 2004). Simple reaction time was measured in divided attention tasks with visual stimuli presented to the left or right of fixation or redundantly to both sides. Experiment 1 tested the prediction that redundancy gain--the decrease in…

  19. 10 CFR 431.324 - Uniform test method for the measurement of energy efficiency of metal halide ballasts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... efficiency of metal halide ballasts. 431.324 Section 431.324 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Metal Halide Lamp Ballasts and Fixtures Test Procedures § 431.324 Uniform test method for the measurement of energy efficiency of metal...

  20. 10 CFR 431.134 - Uniform test methods for the measurement of energy and water consumption of automatic commercial...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy DEPARTMENT OF... Automatic Commercial Ice Makers Test Procedures § 431.134 Uniform test methods for the measurement of energy and water consumption of automatic commercial ice makers. (a) Scope. This section provides the test...

  1. 10 CFR 431.134 - Uniform test methods for the measurement of energy and water consumption of automatic commercial...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy DEPARTMENT OF... Automatic Commercial Ice Makers Test Procedures § 431.134 Uniform test methods for the measurement of energy and water consumption of automatic commercial ice makers. (a) Scope. This section provides the test...

  2. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of commercial air conditioners and...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... efficiency of commercial air conditioners and heat pumps. 431.96 Section 431.96 Energy DEPARTMENT OF ENERGY... Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the measurement of energy efficiency of commercial air conditioners and heat pumps. (a) Scope. This section contains test...

  3. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of commercial air conditioners and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... efficiency of commercial air conditioners and heat pumps. 431.96 Section 431.96 Energy DEPARTMENT OF ENERGY... Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the measurement of energy efficiency of commercial air conditioners and heat pumps. (a) Scope. This section contains test...

  4. Modern molecular study of weight gain related to antidepressant treatment: clinical implications of the pharmacogenetic testing.

    PubMed

    Ageu, Luminiţa Ştefania; Levai, Codrina Mihaela; Andreescu, Nicoleta Ioana; Grigoraş, Mirela Loredana; Hogea, Lavinia Maria; Chiriac, Daniela Veronica; Folescu, Roxana; Bredicean, Ana Cristina; Nussbaum, Liliana Maria; Enătescu, Virgil Radu; Poroch, Vladimir; Lupu, Viorel; Puiu, Maria; Nussbaum, Laura Alexandra

    2018-01-01

    Antidepressant medication influences cellular lipogenesis, being associated with metabolic side effects including weight gain. Due to the increasing use of antidepressants in children and adolescents, their metabolic and endocrine adverse effects are of particular concern, especially within this pediatric population that appears to be at greater risk. Genetic factors with a possible influence on antidepressant's adverse effects include CYP [cytochrome P450 (CYP450)] polymorphisms. We target to evaluate the efficacy of the pharmacogenetic testing, when prescribing antidepressants, in correlation with the occurrence of adverse events and weight gain. Our research was performed between the years 2010 and 2016, in the University Clinic of Child and Adolescent Psychiatry, Timisoara, Romania. We recruited 80 patients, children and adolescents with depressive disorders. Our study sample was divided in two groups: G1 - 40 patients took treatment after pharmacogenetic testing, and G2 - 40 patients without pharmacogenetic testing before the treatment election. Our results show statistically significant differences concerning the weight gain for groups G1 (with pharmacogenetic testing) and G2 (without pharmacogenetic testing). The CYP genotype and the pharmacogenetic testing, for choosing the personalized antidepressant therapy in children and adolescents with depressive disorders, proved to be good predictors for the response to antidepressants and the side effects registered, especially for weight gain. The significant correlations between the CYP polymorphisms for group G2 (without pharmacogenetic testing) and the weight gain/body mass index (BMI) increase, as major side effects induced by antidepressants, proved the fact that the pharmacogenetic screening is needed in the future clinical practice, allowing for individualized, tailored treatment, especially for at-risk pediatric categories.

  5. Development of Drop/Shock Test in Microelectronics and Impact Dynamic Analysis for Uniform Board Response

    NASA Astrophysics Data System (ADS)

    Kallolimath, Sharan Chandrashekar

    For the past several years, many researchers are constantly developing and improving board level drop test procedures and specifications to quantify the solder joint reliability performance of consumer electronics products. Predictive finite element analysis (FEA) by utilizing simulation software has become widely acceptable verification method which can reduce time and cost of the real-time test process. However, due to testing and metrological limitations it is difficult not only to simulate exact drop condition and capture critical measurement data but also tedious to calibrate the system to improve test methods. Moreover, some of the important ever changing factors such as board flexural rigidity, damping, drop height, and drop orientation results in non-uniform stress/strain distribution throughout the test board. In addition, one of the most challenging tasks is to quantify uniform stress and strain distribution throughout the test board and identify critical failure factors. The major contributions of this work are in the four aspects of the drop test in electronics as following. First of all, an analytical FEA model was developed to study the board natural frequencies and responses of the system with the consideration of dynamic stiffness, damping behavior of the material and effect of impact loading condition. An approach to find the key parameters that affect stress and strain distributions under predominate mode responses was proposed and verified with theoretical solutions. Input-G method was adopted to study board response behavior and cut boundary interpolation methods was used to analyze local model solder joint stresses with the development of global/local FEA model in ANSYS software. Second, no ring phenomenon during the drop test was identified theoretically when the test board was modeled as both discrete system and continuous system. Numerical analysis was then conducted by FEA method for detailed geometry of attached chips with solder

  6. 10 CFR 431.134 - Uniform test methods for the measurement of energy consumption and water consumption of automatic...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... consumption and water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy... EQUIPMENT Automatic Commercial Ice Makers Test Procedures § 431.134 Uniform test methods for the measurement of energy consumption and water consumption of automatic commercial ice makers. (a) Scope. This...

  7. Sensation Seeking as a Moderator of Gain- and Loss-Framed HIV-Test Promotion Message Effects.

    PubMed

    Hull, Shawnika J; Hong, Yangsun

    2016-01-01

    This study used an experiment (N = 504) to test whether the fit between sensation-seeking disposition and frame enhances the persuasiveness of gain- and loss-framed HIV test promotion messages. Gain- and loss-framed messages may be consistent with low and high sensation seekers' disposition with respect to risk behavior. We hypothesized that a loss-framed message would be more persuasive for high sensation seekers and that a gain-framed message should be more effective for low sensation seekers. We also expected elaboration to mediate the interaction. Results demonstrated the hypothesized interaction. When the message frame fit with the viewer's way of thinking, the persuasive power of the message was enhanced. The mediation hypothesis was not supported. Practical implications for targeting and message design are discussed.

  8. Effects of Lambertian sources design on uniformity and measurements

    NASA Astrophysics Data System (ADS)

    Cariou, Nadine; Durell, Chris; McKee, Greg; Wilks, Dylan; Glastre, Wilfried

    2014-10-01

    Integrating sphere (IS) based uniform sources are a primary tool for ground based calibration, characterization and testing of flight radiometric equipment. The idea of a Lambertian field of energy is a very useful tool in radiometric testing, but this concept is being checked in many ways by newly lowered uncertainty goals. At an uncertainty goal of 2% one needs to assess carefully uniformity in addition to calibration uncertainties, as even sources with a 0.5% uniformity are now substantial proportions of uncertainty budgets. The paper explores integrating sphere design options for achieving 99.5% and better uniformity of exit port radiance and spectral irradiance created by an integrating sphere. Uniformity in broad spectrum and spectral bands are explored. We discuss mapping techniques and results as a function of observed uniformity as well as laboratory testing results customized to match with customer's instrumentation field of view. We will also discuss recommendations with basic commercial instrumentation, we have used to validate, inspect, and improve correlation of uniformity measurements with the intended application.

  9. 10 CFR Appendix X to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of Dehumidifiers X Appendix X to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. X Appendix X to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  10. 10 CFR Appendix X to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of Dehumidifiers X Appendix X to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. X Appendix X to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  11. 10 CFR Appendix X to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of Dehumidifiers X Appendix X to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. X Appendix X to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  12. 10 CFR Appendix X to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... of Dehumidifiers X Appendix X to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. X Appendix X to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  13. 10 CFR Appendix X to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... of Dehumidifiers X Appendix X to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. X Appendix X to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  14. 10 CFR Appendix A to Subpart K of... - Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... test more than one unit of a basic model to determine the efficiency of that basic model, the... one ampere and the test current is limited to 15 percent of the winding current. Connect the... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Energy Consumption...

  15. 10 CFR Appendix A to Subpart K of... - Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... test more than one unit of a basic model to determine the efficiency of that basic model, the... one ampere and the test current is limited to 15 percent of the winding current. Connect the... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption...

  16. 10 CFR Appendix A to Subpart K of... - Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... test more than one unit of a basic model to determine the efficiency of that basic model, the... one ampere and the test current is limited to 15 percent of the winding current. Connect the... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption...

  17. 10 CFR Appendix A to Subpart K of... - Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... test more than one unit of a basic model to determine the efficiency of that basic model, the... one ampere and the test current is limited to 15 percent of the winding current. Connect the... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption...

  18. GPR monitoring for non-uniform infiltration through a high permeable gravel layer in the test sand box

    NASA Astrophysics Data System (ADS)

    Kuroda, Seiichiro; Ishii, Nobuyuki; Morii, Toshihiro

    2017-04-01

    Recently capillary barriers have been known as a method to protect subsurface regions against infiltration from soil surface. It has essentially non-uniform structure of permeability or soil physical property. To identify the function of the capillary barrier, the site-characterization technique for non-uniform soil moisture distribution and infiltration process is needed. We built a sand box in which a thin high-permeable gravel layer was embedded and conducted a infiltration test, including non-uniform flow of soil water induced by capillary barrier effects. We monitored this process by various types of GPR measurements, including time-lapsed soundings with multi-frequency antenna and transmission measurements like one using cross-borehole radar. Finally we will discuss the applicability of GPR for monitoring the phenomena around the capillary barrier of soil. This work has partially supported by JSPS Grant-in-aid Scientific Research program, No.16H02580.

  19. 10 CFR 431.134 - Uniform test methods for the measurement of energy consumption and water consumption of automatic...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform test methods for the measurement of energy consumption and water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Automatic Commercial Ice Makers Test...

  20. 10 CFR 431.134 - Uniform test methods for the measurement of energy consumption and water consumption of automatic...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test methods for the measurement of energy consumption and water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Automatic Commercial Ice Makers Test...

  1. Impact of uniform electrode current distribution on ETF. [Engineering Test Facility MHD generator

    NASA Technical Reports Server (NTRS)

    Bents, D. J.

    1982-01-01

    A basic reason for the complexity and sheer volume of electrode consolidation hardware in the MHD ETF Powertrain system is the channel electrode current distribution, which is non-uniform. If the channel design is altered to provide uniform electrode current distribution, the amount of hardware required decreases considerably, but at the possible expense of degraded channel performance. This paper explains the design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution, and presents the alternate consolidation designs which occur. They are compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is presented for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.

  2. Do Men and Women Need to Be Screened Differently with Fecal Immunochemical Testing? A Cost-Effectiveness Analysis.

    PubMed

    Meulen, Miriam P van der; Kapidzic, Atija; Leerdam, Monique E van; van der Steen, Alex; Kuipers, Ernst J; Spaander, Manon C W; de Koning, Harry J; Hol, Lieke; Lansdorp-Vogelaar, Iris

    2017-08-01

    Background: Several studies suggest that test characteristics for the fecal immunochemical test (FIT) differ by gender, triggering a debate on whether men and women should be screened differently. We used the microsimulation model MISCAN-Colon to evaluate whether screening stratified by gender is cost-effective. Methods: We estimated gender-specific FIT characteristics based on first-round positivity and detection rates observed in a FIT screening pilot (CORERO-1). Subsequently, we used the model to estimate harms, benefits, and costs of 480 gender-specific FIT screening strategies and compared them with uniform screening. Results: Biennial FIT screening from ages 50 to 75 was less effective in women than men [35.7 vs. 49.0 quality-adjusted life years (QALY) gained, respectively] at higher costs (€42,161 vs. -€5,471, respectively). However, the incremental QALYs gained and costs of annual screening compared with biennial screening were more similar for both genders (8.7 QALYs gained and €26,394 for women vs. 6.7 QALYs gained and €20,863 for men). Considering all evaluated screening strategies, optimal gender-based screening yielded at most 7% more QALYs gained than optimal uniform screening and even resulted in equal costs and QALYs gained from a willingness-to-pay threshold of €1,300. Conclusions: FIT screening is less effective in women, but the incremental cost-effectiveness is similar in men and women. Consequently, screening stratified by gender is not more cost-effective than uniform FIT screening. Impact: Our conclusions support the current policy of uniform FIT screening. Cancer Epidemiol Biomarkers Prev; 26(8); 1328-36. ©2017 AACR . ©2017 American Association for Cancer Research.

  3. Influence of movable test section elements configuration on its drag and flow field uniformity at transonic speeds

    NASA Astrophysics Data System (ADS)

    Glazkov, S. A.; Gorbushin, A. R.; Osipova, S. L.; Semenov, A. V.

    2016-10-01

    The report describes the results of flow field experimental research in TsAGI T-128 transonic wind tunnel. During the tests Mach number, stagnation pressure, test section wall perforation ratio, angles between the test section panels and mixing chamber flaps varied. Based on the test results one determined corrections to the free-stream Mach number related to the flow speed difference in the model location and in the zone of static pressure measurement on the test section walls, nonuniformity of the longitudinal velocity component in the model location, optimal position of the movable test section elements to provide flow field uniformity in the test section and minimize the test leg drag.

  4. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of small, large, and very large...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., packaged terminal air conditioners, and packaged terminal heat pumps. 431.96 Section 431.96 Energy... EQUIPMENT Commercial Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the... heating equipment, packaged terminal air conditioners, and packaged terminal heat pumps. (a) Scope. This...

  5. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of small, large, and very large...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., packaged terminal air conditioners, and packaged terminal heat pumps. 431.96 Section 431.96 Energy... EQUIPMENT Commercial Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the... heating equipment, packaged terminal air conditioners, and packaged terminal heat pumps. (a) Scope. This...

  6. A synopsis of test results and knowledge gained from the Phase-0 CSI evolutionary model

    NASA Technical Reports Server (NTRS)

    Belvin, W. Keith; Elliott, Kenny B.; Horta, Lucas G.

    1993-01-01

    The Phase-0 CSI Evolutionary Model (CEM) is a testbed for the study of space platform global line-of-sight (LOS) pointing. Now that the tests have been completed, a summary of hardware and closed-loop test experiences is necessary to insure a timely dissemination of the knowledge gained. The testbed is described and modeling experiences are presented followed by a summary of the research performed by various investigators. Some early lessons on implementing the closed-loop controllers are described with particular emphasis on real-time computing requirements. A summary of closed-loop studies and a synopsis of test results are presented. Plans for evolving the CEM from phase 0 to phases 1 and 2 are also described. Subsequently, a summary of knowledge gained from the design and testing of the Phase-0 CEM is made.

  7. 10 CFR Appendix N to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... furnaces without stack dampers with adjustable fan control—cool-down test. For a furnace with adjustable... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. N...

  8. 10 CFR 431.86 - Uniform test method for the measurement of energy efficiency of commercial packaged boilers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform test method for the measurement of energy efficiency of commercial packaged boilers. 431.86 Section 431.86 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Packaged...

  9. 10 CFR 431.86 - Uniform test method for the measurement of energy efficiency of commercial packaged boilers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform test method for the measurement of energy efficiency of commercial packaged boilers. 431.86 Section 431.86 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Packaged...

  10. 10 CFR 431.86 - Uniform test method for the measurement of energy efficiency of commercial packaged boilers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform test method for the measurement of energy efficiency of commercial packaged boilers. 431.86 Section 431.86 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Packaged...

  11. 10 CFR 431.86 - Uniform test method for the measurement of energy efficiency of commercial packaged boilers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform test method for the measurement of energy efficiency of commercial packaged boilers. 431.86 Section 431.86 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Packaged...

  12. Reverberation Chamber Uniformity Validation and Radiated Susceptibility Test Procedures for the NASA High Intensity Radiated Fields Laboratory

    NASA Technical Reports Server (NTRS)

    Koppen, Sandra V.; Nguyen, Truong X.; Mielnik, John J.

    2010-01-01

    The NASA Langley Research Center's High Intensity Radiated Fields Laboratory has developed a capability based on the RTCA/DO-160F Section 20 guidelines for radiated electromagnetic susceptibility testing in reverberation chambers. Phase 1 of the test procedure utilizes mode-tuned stirrer techniques and E-field probe measurements to validate chamber uniformity, determines chamber loading effects, and defines a radiated susceptibility test process. The test procedure is segmented into numbered operations that are largely software controlled. This document is intended as a laboratory test reference and includes diagrams of test setups, equipment lists, as well as test results and analysis. Phase 2 of development is discussed.

  13. GPM High Gain Antenna System Testing

    NASA Image and Video Library

    2014-02-20

    File: 03/26/2012 The GPM High Gain Antenna System (HGAS) in integration and testing at Goddard Space Flight Center. GPM is a joint mission between NASA and the Japan Aerospace Exploration Agency (JAXA). The Core Observatory will link data from a constellation of current and planned satellites to produce next-generation global measurements of rainfall and snowfall from space. The GPM mission is the first coordinated international satellite network to provide near real-time observations of rain and snow every three hours anywhere on the globe. The GPM Core Observatory anchors this network by providing observations on all types of precipitation. The observatory's data acts as the measuring stick by which partner observations can be combined into a unified data set. The data will be used by scientists to study climate change, freshwater resources, floods and droughts, and hurricane formation and tracking. Credit: Craig E. Huber, Chief Engineer SGT Inc, NASA Goddard Space Flight Center NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  14. 10 CFR Appendix P to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Pool Heaters

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption of Pool Heaters P Appendix P to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. P Appendix P to...

  15. 10 CFR Appendix P to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Pool Heaters

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption of Pool Heaters P Appendix P to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. P Appendix P to...

  16. 10 CFR Appendix N to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the damper remains open during the cool-down test. For furnaces that employ post purge, measure the... control—cool-down test. For a furnace with adjustable fan control, this time delay will be 3.0 minutes for... 10 Energy 3 2014-01-01 2014-01-01 false Uniform Test Method for Measuring the Energy Consumption...

  17. 10 CFR Appendix N to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the damper remains open during the cool-down test. For furnaces that employ post purge, measure the... control—cool-down test. For a furnace with adjustable fan control, this time delay will be 3.0 minutes for... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption...

  18. 10 CFR Appendix N to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the damper remains open during the cool-down test. For furnaces that employ post purge, measure the... control—cool-down test. For a furnace with adjustable fan control, this time delay will be 3.0 minutes for... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption...

  19. 10 CFR Appendix N to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the damper remains open during the cool-down test. For furnaces that employ post purge, measure the... control—cool-down test. For a furnace with adjustable fan control, this time delay will be 3.0 minutes for... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Energy Consumption...

  20. Shutterless non-uniformity correction for the long-term stability of an uncooled long-wave infrared camera

    NASA Astrophysics Data System (ADS)

    Liu, Chengwei; Sui, Xiubao; Gu, Guohua; Chen, Qian

    2018-02-01

    For the uncooled long-wave infrared (LWIR) camera, the infrared (IR) irradiation the focal plane array (FPA) receives is a crucial factor that affects the image quality. Ambient temperature fluctuation as well as system power consumption can result in changes of FPA temperature and radiation characteristics inside the IR camera; these will further degrade the imaging performance. In this paper, we present a novel shutterless non-uniformity correction method to compensate for non-uniformity derived from the variation of ambient temperature. Our method combines a calibration-based method and the properties of a scene-based method to obtain correction parameters at different ambient temperature conditions, so that the IR camera performance can be less influenced by ambient temperature fluctuation or system power consumption. The calibration process is carried out in a temperature chamber with slowly changing ambient temperature and a black body as uniform radiation source. Enough uniform images are captured and the gain coefficients are calculated during this period. Then in practical application, the offset parameters are calculated via the least squares method based on the gain coefficients, the captured uniform images and the actual scene. Thus we can get a corrected output through the gain coefficients and offset parameters. The performance of our proposed method is evaluated on realistic IR images and compared with two existing methods. The images we used in experiments are obtained by a 384× 288 pixels uncooled LWIR camera. Results show that our proposed method can adaptively update correction parameters as the actual target scene changes and is more stable to temperature fluctuation than the other two methods.

  1. 10 CFR Appendix A to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Electric Refrigerators and Electric...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the test for a unit having no defrost provisions (section 4.1). The second part is designed to capture... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption... Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test...

  2. 10 CFR Appendix S to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads S Appendix S to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. S...

  3. 10 CFR Appendix S to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads S Appendix S to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. S...

  4. 10 CFR Appendix S to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads S Appendix S to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. S...

  5. The relative persuasiveness of gain-framed versus loss-Framed HIV testing message: evidence from a field experiment in northwest Ethiopia.

    PubMed

    Bekalu, Mesfin Awoke; Eggermont, Steven

    2014-01-01

    This study assessed the relative advantages of gain- versus loss-framed messages for promoting HIV testing among a sample of urban and rural residents in northwest Ethiopia. The authors randomly assigned 394 participants to read gain-framed (n = 196) or loss-framed (n = 198) HIV testing message prepared in a form of brochure. Experience with HIV testing, concern about and information needs on HIV/AIDS, and urbanity versus rurality significantly moderated the effects of framing on intention to test for HIV. A gain-frame advantage was found among urbanites, participants with high experience with HIV testing, and those with high concern about and information needs on HIV/AIDS, suggesting a more likely construal of HIV testing as a prevention behavior among these individuals. In contrast, a loss-frame advantage was found among ruralites and participants with low concern about and information needs on HIV/AIDS, suggesting a more likely construal of HIV testing as a detection behavior among such individuals. Moreover, gain- and loss-framing led to similar outcomes among individuals with low levels of experience with HIV testing, with a slight advantage for the loss-framed message. All of the framing effects obtained were of small to medium size.

  6. 10 CFR Appendix Q to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Fluorescent Lamp Ballasts

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of Fluorescent Lamp Ballasts Q Appendix Q to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. Q Appendix Q to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Fluorescent...

  7. 10 CFR Appendix Q to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Fluorescent Lamp Ballasts

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of Fluorescent Lamp Ballasts Q Appendix Q to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. Q Appendix Q to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Fluorescent...

  8. 10 CFR Appendix Q to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Fluorescent Lamp Ballasts

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of Fluorescent Lamp Ballasts Q Appendix Q to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. Q Appendix Q to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Fluorescent...

  9. 10 CFR 431.224 - Uniform test method for the measurement of energy consumption for traffic signal modules and...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy consumption for traffic signal modules and pedestrian modules. 431.224 Section 431.224 Energy DEPARTMENT OF... measurement of energy consumption for traffic signal modules and pedestrian modules. (a) Scope. This section...

  10. Effects of broiler breeder management on pullet body weight and carcass uniformity.

    PubMed

    Zuidhof, M J; Holm, D E; Renema, R A; Jalal, M A; Robinson, F E

    2015-06-01

    An experiment was conducted to study the effect of broiler breeder feeding management practices on pullet performance, BW uniformity, and carcass traits during rearing (to 22 wk of age). At 3 wk of age, 1,200 Ross 308 breeder pullets were assigned to one of 5 treatments: 1) control: standard mash diet, fed daily; 2) high fiber: mash diet containing 25% lower nutrient density, fed daily; 3) scatter: standard diet in pellet form scattered on litter, fed daily; 4) skip-a-day: standard mash diet, fed on alternate days; or 5) grading: standard mash diet, fed daily (birds sorted into low, average, and high BW groups every 4 wk). Birds on the high fiber treatment consumed more feed (P<0.0001) and had the highest feed conversion ratio (FCR; P<0.004) but the lowest ME to gain and CP to gain ratios (P≤0.002). Skip-a-day treatment pullets consumed more ME and CP than birds in any other treatment (P<0.001). Grading yielded the highest BW uniformity at 22 wk of age (CV=6.2%), while control and high fiber treatment groups were least uniform (CV>15%; P<0.0001). Skip-a-day feed restriction produced birds with the significantly lowest breast muscle and highest liver weight compared to all other treatments (P<0.05). Variation in shank length, chest width, and breast muscle was lowest in the grading treatment, whereas the CV for fat pad and liver was lowest in the skip-a-day treatment. In this trial, broiler breeder target BW profiles were achieved using combinations of quantitative and qualitative feed restriction, or preemptive management practices. Qualitative diet dilution and skip-a-day management did little to increase flock uniformity relative to the control during the most intense period of feed restriction (7 to 19 wk). Scatter feeding increased flock uniformity to a small degree, whereas grading yielded the highest increase in BW and carcass trait uniformity. © 2015 Poultry Science Association Inc.

  11. Capacity achieving nonbinary LDPC coded non-uniform shaping modulation for adaptive optical communications.

    PubMed

    Lin, Changyu; Zou, Ding; Liu, Tao; Djordjevic, Ivan B

    2016-08-08

    A mutual information inspired nonbinary coded modulation design with non-uniform shaping is proposed. Instead of traditional power of two signal constellation sizes, we design 5-QAM, 7-QAM and 9-QAM constellations, which can be used in adaptive optical networks. The non-uniform shaping and LDPC code rate are jointly considered in the design, which results in a better performance scheme for the same SNR values. The matched nonbinary (NB) LDPC code is used for this scheme, which further improves the coding gain and the overall performance. We analyze both coding performance and system SNR performance. We show that the proposed NB LDPC-coded 9-QAM has more than 2dB gain in symbol SNR compared to traditional LDPC-coded star-8-QAM. On the other hand, the proposed NB LDPC-coded 5-QAM and 7-QAM have even better performance than LDPC-coded QPSK.

  12. Uniform Foam Crush Testing for Multi-Mission Earth Entry Vehicle Impact Attenuation

    NASA Technical Reports Server (NTRS)

    Patterson, Byron W.; Glaab, Louis J.

    2012-01-01

    Multi-Mission Earth Entry Vehicles (MMEEVs) are blunt-body vehicles designed with the purpose of transporting payloads from outer space to the surface of the Earth. To achieve high-reliability and minimum weight, MMEEVs avoid use of limited-reliability systems, such as parachutes and retro-rockets, instead using built-in impact attenuators to absorb energy remaining at impact to meet landing loads requirements. The Multi-Mission Systems Analysis for Planetary Entry (M-SAPE) parametric design tool is used to facilitate the design of MMEEVs and develop the trade space. Testing was conducted to characterize the material properties of several candidate impact foam attenuators to enhance M-SAPE analysis. In the current effort, four different Rohacell foams are tested at three different, uniform, strain rates (approximately 0.17, approximately 100, approximately 13,600%/s). The primary data analysis method uses a global data smoothing technique in the frequency domain to remove noise and system natural frequencies. The results from the data indicate that the filter and smoothing technique are successful in identifying the foam crush event and removing aberrations. The effect of strain rate increases with increasing foam density. The 71-WF-HT foam may support Mars Sample Return requirements. Several recommendations to improve the drop tower test technique are identified.

  13. 10 CFR Appendix B to Subpart B of... - Uniform Test Method for Measuring Nominal Full Load Efficiency of Electric Motors

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Efficiency of Electric Motors B Appendix B to Subpart B of Part 431 Energy DEPARTMENT OF ENERGY ENERGY..., Subpt. B, App. B Appendix B to Subpart B of Part 431—Uniform Test Method for Measuring Nominal Full Load... Std 112-2004 Test Method B, Input-Output With Loss Segregation, (incorporated by reference, see § 431...

  14. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. [Reserved] 431.107 Section 431.107 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Water Heaters, Hot Water Supply Boilers...

  15. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. [Reserved] 431.107 Section 431.107 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Water Heaters, Hot Water Supply Boilers...

  16. Measurement uncertainty for the Uniform Engine Testing Program conducted at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Abdelwahab, Mahmood; Biesiadny, Thomas J.; Silver, Dean

    1987-01-01

    An uncertainty analysis was conducted to determine the bias and precision errors and total uncertainty of measured turbojet engine performance parameters. The engine tests were conducted as part of the Uniform Engine Test Program which was sponsored by the Advisory Group for Aerospace Research and Development (AGARD). With the same engines, support hardware, and instrumentation, performance parameters were measured twice, once during tests conducted in test cell number 3 and again during tests conducted in test cell number 4 of the NASA Lewis Propulsion Systems Laboratory. The analysis covers 15 engine parameters, including engine inlet airflow, engine net thrust, and engine specific fuel consumption measured at high rotor speed of 8875 rpm. Measurements were taken at three flight conditions defined by the following engine inlet pressure, engine inlet total temperature, and engine ram ratio: (1) 82.7 kPa, 288 K, 1.0, (2) 82.7 kPa, 288 K, 1.3, and (3) 20.7 kPa, 288 K, 1.3. In terms of bias, precision, and uncertainty magnitudes, there were no differences between most measurements made in test cells number 3 and 4. The magnitude of the errors increased for both test cells as engine pressure level decreased. Also, the level of the bias error was two to three times larger than that of the precision error.

  17. Tailoring auditory training to patient needs with single and multiple talkers: transfer-appropriate gains on a four-choice discrimination test.

    PubMed

    Barcroft, Joe; Sommers, Mitchell S; Tye-Murray, Nancy; Mauzé, Elizabeth; Schroy, Catherine; Spehar, Brent

    2011-11-01

    Our long-term objective is to develop an auditory training program that will enhance speech recognition in those situations where patients most want improvement. As a first step, the current investigation trained participants using either a single talker or multiple talkers to determine if auditory training leads to transfer-appropriate gains. The experiment implemented a 2 × 2 × 2 mixed design, with training condition as a between-participants variable and testing interval and test version as repeated-measures variables. Participants completed a computerized six-week auditory training program wherein they heard either the speech of a single talker or the speech of six talkers. Training gains were assessed with single-talker and multi-talker versions of the Four-choice discrimination test. Participants in both groups were tested on both versions. Sixty-nine adult hearing-aid users were randomly assigned to either single-talker or multi-talker auditory training. Both groups showed significant gains on both test versions. Participants who trained with multiple talkers showed greater improvement on the multi-talker version whereas participants who trained with a single talker showed greater improvement on the single-talker version. Transfer-appropriate gains occurred following auditory training, suggesting that auditory training can be designed to target specific patient needs.

  18. 10 CFR Appendix V to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan Light Kits

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... of Ceiling Fan Light Kits V Appendix V to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. V Appendix V to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan...

  19. Tuning of gravity-dependent and gravity-independent vertical angular VOR gain changes by frequency of adaptation

    PubMed Central

    2012-01-01

    The gain of the vertical angular vestibulo-ocular reflex (aVOR) was adaptively increased and decreased in a side-down head orientation for 4 h in two cynomolgus monkeys. Adaptation was performed at 0.25, 1, 2, or 4 Hz. The gravity-dependent and -independent gain changes were determined over a range of head orientations from left-side-down to right-side-down at frequencies from 0.25 to 10 Hz, before and after adaptation. Gain changes vs. frequency data were fit with a Gaussian to determine the frequency at which the peak gain change occurred, as well as the tuning width. The frequency at which the peak gravity-dependent gain change occurred was approximately equal to the frequency of adaptation, and the width increased monotonically with increases in the frequency of adaptation. The gravity-independent component was tuned to the adaptive frequency of 0.25 Hz but was uniformly distributed over all frequencies when the adaptation frequency was 1–4 Hz. The amplitude of the gravity-independent gain changes was larger after the aVOR gain decrease than after the gain increase across all tested frequencies. For the aVOR gain decrease, the phase lagged about 4° for frequencies below the adaptation frequency and led for frequencies above the adaptation frequency. For gain increases, the phase relationship as a function of frequency was inverted. This study demonstrates that the previously described dependence of aVOR gain adaptation on frequency is a property of the gravity-dependent component of the aVOR only. The gravity-independent component of the aVOR had a substantial tuning curve only at an adaptation frequency of 0.25 Hz. PMID:22402654

  20. Tuning of gravity-dependent and gravity-independent vertical angular VOR gain changes by frequency of adaptation.

    PubMed

    Yakushin, Sergei B

    2012-06-01

    The gain of the vertical angular vestibulo-ocular reflex (aVOR) was adaptively increased and decreased in a side-down head orientation for 4 h in two cynomolgus monkeys. Adaptation was performed at 0.25, 1, 2, or 4 Hz. The gravity-dependent and -independent gain changes were determined over a range of head orientations from left-side-down to right-side-down at frequencies from 0.25 to 10 Hz, before and after adaptation. Gain changes vs. frequency data were fit with a Gaussian to determine the frequency at which the peak gain change occurred, as well as the tuning width. The frequency at which the peak gravity-dependent gain change occurred was approximately equal to the frequency of adaptation, and the width increased monotonically with increases in the frequency of adaptation. The gravity-independent component was tuned to the adaptive frequency of 0.25 Hz but was uniformly distributed over all frequencies when the adaptation frequency was 1-4 Hz. The amplitude of the gravity-independent gain changes was larger after the aVOR gain decrease than after the gain increase across all tested frequencies. For the aVOR gain decrease, the phase lagged about 4° for frequencies below the adaptation frequency and led for frequencies above the adaptation frequency. For gain increases, the phase relationship as a function of frequency was inverted. This study demonstrates that the previously described dependence of aVOR gain adaptation on frequency is a property of the gravity-dependent component of the aVOR only. The gravity-independent component of the aVOR had a substantial tuning curve only at an adaptation frequency of 0.25 Hz.

  1. Ejector Enhanced Pulsejet Based Pressure Gain Combustors: An Old Idea With a New Twist

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.; Dougherty, Kevin T.

    2005-01-01

    An experimental investigation of pressure-gain combustion for gas turbine application is described. The test article consists of an off-the-shelf valved pulsejet, and an optimized ejector, both housed within a shroud. The combination forms an effective can combustor across which there is a modest total pressure rise rather than the usual loss found in conventional combustors. Although the concept of using a pulsejet to affect semi-constant volume (i.e., pressure-gain) combustion is not new, that of combining it with a well designed ejector to efficiently mix the bypass flow is. The result is a device which to date has demonstrated an overall pressure rise of approximately 3.5 percent at an overall temperature ratio commensurate with modern gas turbines. This pressure ratio is substantially higher than what has been previously reported in pulsejet-based combustion experiments. Flow non-uniformities in the downstream portion of the device are also shown to be substantially reduced compared to those within the pulsejet itself. The standard deviation of total pressure fluctuations, measured just downstream of the ejector was only 5.0 percent of the mean. This smoothing aspect of the device is critical to turbomachinery applications since turbine performance is, in general, negatively affected by flow non-uniformities and unsteadiness. The experimental rig will be described and details of the performance measurements will be presented. Analyses showing the thermodynamic benefits from this level of pressure-gain performance in a gas turbine will also be assessed for several engine types. Issues regarding practical development of such a device are discussed, as are potential emissions reductions resulting from the rich burning nature of the pulsejet and the rapid mixing (quenching) associated with unsteady ejectors.

  2. 34 CFR 462.4 - What are the transition rules for using tests to measure educational gain for the National...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... measure educational gain for the National Reporting System for Adult Education (NRS)? 462.4 Section 462.4... ADULT EDUCATION, DEPARTMENT OF EDUCATION MEASURING EDUCATIONAL GAIN IN THE NATIONAL REPORTING SYSTEM FOR ADULT EDUCATION General § 462.4 What are the transition rules for using tests to measure educational...

  3. 34 CFR 462.4 - What are the transition rules for using tests to measure educational gain for the National...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... measure educational gain for the National Reporting System for Adult Education (NRS)? 462.4 Section 462.4... ADULT EDUCATION, DEPARTMENT OF EDUCATION MEASURING EDUCATIONAL GAIN IN THE NATIONAL REPORTING SYSTEM FOR ADULT EDUCATION General § 462.4 What are the transition rules for using tests to measure educational...

  4. 34 CFR 462.4 - What are the transition rules for using tests to measure educational gain for the National...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... measure educational gain for the National Reporting System for Adult Education (NRS)? 462.4 Section 462.4... ADULT EDUCATION, DEPARTMENT OF EDUCATION MEASURING EDUCATIONAL GAIN IN THE NATIONAL REPORTING SYSTEM FOR ADULT EDUCATION General § 462.4 What are the transition rules for using tests to measure educational...

  5. 34 CFR 462.4 - What are the transition rules for using tests to measure educational gain for the National...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... measure educational gain for the National Reporting System for Adult Education (NRS)? 462.4 Section 462.4... ADULT EDUCATION, DEPARTMENT OF EDUCATION MEASURING EDUCATIONAL GAIN IN THE NATIONAL REPORTING SYSTEM FOR ADULT EDUCATION General § 462.4 What are the transition rules for using tests to measure educational...

  6. Isospectrals of non-uniform Rayleigh beams with respect to their uniform counterparts

    PubMed Central

    Ganguli, Ranjan

    2018-01-01

    In this paper, we look for non-uniform Rayleigh beams isospectral to a given uniform Rayleigh beam. Isospectral systems are those that have the same spectral properties, i.e. the same free vibration natural frequencies for a given boundary condition. A transformation is proposed that converts the fourth-order governing differential equation of non-uniform Rayleigh beam into a uniform Rayleigh beam. If the coefficients of the transformed equation match with those of the uniform beam equation, then the non-uniform beam is isospectral to the given uniform beam. The boundary-condition configuration should be preserved under this transformation. We present the constraints under which the boundary configurations will remain unchanged. Frequency equivalence of the non-uniform beams and the uniform beam is confirmed by the finite-element method. For the considered cases, examples of beams having a rectangular cross section are presented to show the application of our analysis. PMID:29515879

  7. The Alzheimer’s Disease Centers’ Uniform Data Set (UDS): The Neuropsychological Test Battery

    PubMed Central

    Weintraub, Sandra; Salmon, David; Mercaldo, Nathaniel; Ferris, Steven; Graff-Radford, Neill R.; Chui, Helena; Cummings, Jeffrey; DeCarli, Charles; Foster, Norman L.; Galasko, Douglas; Peskind, Elaine; Dietrich, Woodrow; Beekly, Duane L.; Kukull, Walter A.; Morris, John C.

    2009-01-01

    The neuropsychological test battery from the Uniform Data Set (UDS) of the Alzheimer’s Disease Centers (ADC) program of the National Institute on Aging (NIA) consists of brief measures of attention, processing speed, executive function, episodic memory and language. This paper describes development of the battery and preliminary data from the initial UDS evaluation of 3,268 clinically cognitively normal men and women collected over the first 24 months of utilization. The subjects represent a sample of community-dwelling, individuals who volunteer for studies of cognitive aging. Subjects were considered “clinically cognitively normal” based on clinical assessment, including the Clinical Dementia Rating scale and the Functional Assessment Questionnaire. The results demonstrate performance on tests sensitive to cognitive aging and to the early stages of Alzheimer disease (AD) in a relatively well-educated sample. Regression models investigating the impact of age, education, and gender on test scores indicate that these variables will need to be incorporated in subsequent normative studies. Future plans include: 1) determining the psychometric properties of the battery; 2) establishing normative data, including norms for different ethnic minority groups; and 3) conducting longitudinal studies on cognitively normal subjects, individuals with mild cognitive impairment, and individuals with AD and other forms of dementia. PMID:19474567

  8. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters). 431.106 Section 431.106 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL...

  9. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters). 431.106 Section 431.106 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL...

  10. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters). 431.106 Section 431.106 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL...

  11. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters). 431.106 Section 431.106 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL...

  12. Error Rates in Measuring Teacher and School Performance Based on Student Test Score Gains. NCEE 2010-4004

    ERIC Educational Resources Information Center

    Schochet, Peter Z.; Chiang, Hanley S.

    2010-01-01

    This paper addresses likely error rates for measuring teacher and school performance in the upper elementary grades using value-added models applied to student test score gain data. Using realistic performance measurement system schemes based on hypothesis testing, we develop error rate formulas based on OLS and Empirical Bayes estimators.…

  13. Test-Retest Gains in WAIS Scores after Four Retest Intervals.

    ERIC Educational Resources Information Center

    Catron, David W.; Thompson, Claudia C.

    1979-01-01

    To analyze the hypothesis that retest gain scores would decrease in a decelerating curve to zero-gain as the retest interval increased, male college students were administered the WAIS on two occasions with a retest at either 1 week, 2 months, or 4 months. (Author/SJL)

  14. Correcting the Normalized Gain for Guessing

    ERIC Educational Resources Information Center

    Stewart, John; Stewart, Gay

    2010-01-01

    The normalized gain, "g", has been an important tool for the characterization of conceptual improvement in physics courses since its use in Hake's extensive study on conceptual learning in introductory physics. The normalized gain is calculated from the score on a pre-test administered before instruction and a post-test administered…

  15. Covariant Uniform Acceleration

    NASA Astrophysics Data System (ADS)

    Friedman, Yaakov; Scarr, Tzvi

    2013-04-01

    We derive a 4D covariant Relativistic Dynamics Equation. This equation canonically extends the 3D relativistic dynamics equation , where F is the 3D force and p = m0γv is the 3D relativistic momentum. The standard 4D equation is only partially covariant. To achieve full Lorentz covariance, we replace the four-force F by a rank 2 antisymmetric tensor acting on the four-velocity. By taking this tensor to be constant, we obtain a covariant definition of uniformly accelerated motion. This solves a problem of Einstein and Planck. We compute explicit solutions for uniformly accelerated motion. The solutions are divided into four Lorentz-invariant types: null, linear, rotational, and general. For null acceleration, the worldline is cubic in the time. Linear acceleration covariantly extends 1D hyperbolic motion, while rotational acceleration covariantly extends pure rotational motion. We use Generalized Fermi-Walker transport to construct a uniformly accelerated family of inertial frames which are instantaneously comoving to a uniformly accelerated observer. We explain the connection between our approach and that of Mashhoon. We show that our solutions of uniformly accelerated motion have constant acceleration in the comoving frame. Assuming the Weak Hypothesis of Locality, we obtain local spacetime transformations from a uniformly accelerated frame K' to an inertial frame K. The spacetime transformations between two uniformly accelerated frames with the same acceleration are Lorentz. We compute the metric at an arbitrary point of a uniformly accelerated frame. We obtain velocity and acceleration transformations from a uniformly accelerated system K' to an inertial frame K. We introduce the 4D velocity, an adaptation of Horwitz and Piron s notion of "off-shell." We derive the general formula for the time dilation between accelerated clocks. We obtain a formula for the angular velocity of a uniformly accelerated object. Every rest point of K' is uniformly accelerated, and

  16. Progress towards large gain-length products on the Li-like recombination scheme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeitoun, P.; Jamelot, G.; Carillon, A.

    1995-05-01

    Investigating possibilities of attaining large gain-length products on the recombination scheme using lithium-like ions, we have examined two approaches aimed at overcoming the problem of plasma non-uniformity susceptible to destroy gain by a number of processes. In the first approach we studied amplification on the transitions 5f-3d and 4f-3d in Li-like Al{sup 10+} plasma column produced by smoothing optics using lens arrays. Employing this device resulted in the gain holding up significantly longer than when no smoothing optics was used. Second, we have investigated numerically and experimentally the 5g-4f transition in Li-like S{sup 13+}, as the gain should be barelymore » affected by the plasma nonuniformities. Encouraging results were obtained and their various aspects are discussed.« less

  17. 18 CFR 367.4211 - Account 421.1, Gain on disposition of property.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 421.1, Gain on disposition of property. 367.4211 Section 367.4211 Conservation of Power and Water Resources FEDERAL ENERGY..., FEDERAL POWER ACT AND NATURAL GAS ACT UNIFORM SYSTEM OF ACCOUNTS FOR CENTRALIZED SERVICE COMPANIES SUBJECT...

  18. Supplemental Educational Services and Student Test Score Gains: Evidence from a Large, Urban School District

    ERIC Educational Resources Information Center

    Springer, Matthew G.; Pepper, Matthew J.; Ghosh-Dastidar, Bonnie

    2014-01-01

    This study examines the effect of supplemental education services (SES) on student test score gains and whether particular subgroups of students benefit more from NCLB tutoring services. Our sample includes information on students enrolled in third through eighth grades nested in 121 elementary and middle schools over a five-year period comprising…

  19. Differential Rearing Alters Forced Swim Test Behavior, Fluoxetine Efficacy, and Post-Test Weight Gain in Male Rats.

    PubMed

    Arndt, David L; Peterson, Christy J; Cain, Mary E

    2015-01-01

    Environmental factors play a key role in the etiology of depression. The rodent forced swim test (FST) is commonly used as a preclinical model of depression, with increases in escape-directed behavior reflecting antidepressant effects, and increases in immobility reflecting behavioral despair. Environmental enrichment leads to serotonergic alterations in rats, but it is unknown whether these alterations may influence the efficacy of common antidepressants. Male Sprague-Dawley rats were reared in enriched (EC), standard (SC), or isolated (IC) conditions. Following the rearing period, fluoxetine (10 or 20 mg/kg, i.p.) was administered 23.5 hrs, 5 hrs, and 1 hr before locomotor and FST measures. Following locomotor testing and FST exposure, rats were weighed to assess fluoxetine-, FST-, and environmental condition-induced moderations in weight gain. Results revealed an antidepressant effect of environmental enrichment and a depressant effect of isolation. Regardless of significant fluoxetine effects on locomotor activity, fluoxetine generally decreased swimming and increased immobility in all three environmental conditions, with IC-fluoxetine (10 mg/kg) rats and EC-fluoxetine (20 mg/kg) rats swimming less than vehicle counterparts. Subchronic 20 mg/kg fluoxetine also induced significant weight loss, and differential rearing appeared to moderate weight gain following FST stress. These results suggest that differential rearing has the ability to alter FST behaviors, fluoxetine efficacy, and post-stressor well-being. Moreover, 20 mg/kg fluoxetine, administered subchronically, may lead to atypical effects of those commonly observed in the FST, highlighting the importance and impact of both environmental condition and dosing regimen in common animal models of depression.

  20. Differential Rearing Alters Forced Swim Test Behavior, Fluoxetine Efficacy, and Post-Test Weight Gain in Male Rats

    PubMed Central

    Arndt, David L.; Peterson, Christy J.; Cain, Mary E.

    2015-01-01

    Environmental factors play a key role in the etiology of depression. The rodent forced swim test (FST) is commonly used as a preclinical model of depression, with increases in escape-directed behavior reflecting antidepressant effects, and increases in immobility reflecting behavioral despair. Environmental enrichment leads to serotonergic alterations in rats, but it is unknown whether these alterations may influence the efficacy of common antidepressants. Male Sprague-Dawley rats were reared in enriched (EC), standard (SC), or isolated (IC) conditions. Following the rearing period, fluoxetine (10 or 20 mg/kg, i.p.) was administered 23.5 hrs, 5 hrs, and 1 hr before locomotor and FST measures. Following locomotor testing and FST exposure, rats were weighed to assess fluoxetine-, FST-, and environmental condition-induced moderations in weight gain. Results revealed an antidepressant effect of environmental enrichment and a depressant effect of isolation. Regardless of significant fluoxetine effects on locomotor activity, fluoxetine generally decreased swimming and increased immobility in all three environmental conditions, with IC-fluoxetine (10 mg/kg) rats and EC-fluoxetine (20 mg/kg) rats swimming less than vehicle counterparts. Subchronic 20 mg/kg fluoxetine also induced significant weight loss, and differential rearing appeared to moderate weight gain following FST stress. These results suggest that differential rearing has the ability to alter FST behaviors, fluoxetine efficacy, and post-stressor well-being. Moreover, 20 mg/kg fluoxetine, administered subchronically, may lead to atypical effects of those commonly observed in the FST, highlighting the importance and impact of both environmental condition and dosing regimen in common animal models of depression. PMID:26154768

  1. Mandatory School Uniforms.

    ERIC Educational Resources Information Center

    Cohn, Carl A.

    1996-01-01

    Shortly after implementing a mandatory school uniform policy, the Long Beach (California) Public Schools can boast 99% compliance and a substantial reduction in school crime. The uniforms can't be confused with gang colors, save parents money, and help identify outsiders. A sidebar lists ingredients for a mandatory uniform policy. (MLH)

  2. 'Battling my biology': psychological effects of genetic testing for risk of weight gain.

    PubMed

    Meisel, S F; Wardle, J

    2014-04-01

    The availability of genetic tests for multifactorial conditions such as obesity raises concerns that higher-risk results could lead to fatalistic reactions or lower-risk results to complacency. No study has investigated the effects of genetic test feedback for the risk of obesity in non-clinical samples. The present study explored psychological and behavioral reactions to genetic test feedback for a weight related gene (FTO) in a volunteer sample (n = 18) using semi-structured interviews. Respondents perceived the gene test result as scientifically objective; removing some of the emotion attached to the issue of weight control. Those who were struggling with weight control reported relief of self-blame. There was no evidence for either complacency or fatalism; all respondents emphasized the importance of lifestyle choices in long-term weight management, although they recognized the role of both genes and environment. Regardless of the test result, respondents evaluated the testing positively and found it motivating and informative. Genetic test feedback for risk of weight gain may offer psychological benefits beyond its objectively limited clinical utility. As the role of genetic counselors is likely to expand, awareness of reasons for genetic testing for common, complex conditions and reactions to the test result is important.

  3. School Uniforms Redux.

    ERIC Educational Resources Information Center

    Dowling-Sendor, Benjamin

    2002-01-01

    Reviews a recent decision in "Littlefield" by the 5th Circuit upholding a school uniform policy. Advises board member who wish to adopt a school uniform policy to solicit input from parents and students, research the experiences of other school districts with uniform policies, and articulate the interests they wish to promote through uniform…

  4. Tuning gain and bandwidth of traveling wave tubes using metamaterial beam-wave interaction structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lipton, Robert, E-mail: lipton@math.lsu.edu; Polizzi, Anthony, E-mail: polizzi@math.lsu.edu

    We employ metamaterial beam-wave interaction structures for tuning the gain and bandwidth of short traveling wave tubes. The interaction structures are made from metal rings of uniform cross section, which are periodically deployed along the length of the traveling wave tube. The aspect ratio of the ring cross sections is adjusted to control both gain and bandwidth. The frequency of operation is controlled by the filling fraction of the ring cross section with respect to the size of the period cell.

  5. The impact of gestational weight gain in different trimesters of pregnancy on glucose challenge test and gestational diabetes.

    PubMed

    Hantoushzadeh, Sedigheh; Sheikh, Mahdi; Bosaghzadeh, Zeynab; Ghotbizadeh, Fahimeh; Tarafdari, Azam; Panahi, Zahra; Shariat, Mamak

    2016-09-01

    Assessing the effects of excessive weight gain before pregnancy, in the first and second trimesters and in the month preceding glucose challenge test (GCT) on GCT results and gestational diabetes mellitus (GDM). This prospective cohort study evaluated 1279 pregnant women who were referred for their first prenatal visit in 2012-2015. Mother's body mass index (BMI) was recorded before pregnancy, during the first visit and every 4 weeks until 28 gestational weeks. All mothers underwent GCT at 28 weeks and when 1 h glucose ≥140 mg/dL (≥7.8 mmol/L), they were referred for a 100 g fasting glucose 3 h glucose tolerance test. Obesity and being overweight prior to pregnancy were associated with 2.8-fold and 1.5-fold higher rates of developing GDM (p<0.001, p=0.04) and 1.9-fold and 1.8-fold higher rates of having false-positive GCT results (p<0.001). First-trimester excessive weight gain was significantly associated with false-positive GCT in women who were lean, overweight and obese before pregnancy (all p<0.001). When these women kept gaining excessive weight during the subsequent period the risk of developing GDM was significantly increased regardless of their pre-pregnancy BMI (p=0.03). When these women adhered to the recommended weight gain during the subsequent period, the risk of developing GDM was not increased, however the risk of having false-positive GCT remained high (p<0.001). Elevated pre-pregnancy BMI independently increases the risk of GDM and false-positive GCT. First trimester weight gain is the most important predictor of GCT and GDM regardless of pre-pregnancy BMI. The weight gain during the subsequent period affects the risk of developing GDM only in women with excessive first-trimester weight gain. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Development and Pilot Testing of the Eating4two Mobile Phone App to Monitor Gestational Weight Gain.

    PubMed

    Knight-Agarwal, Catherine; Davis, Deborah Lee; Williams, Lauren; Davey, Rachel; Cox, Robert; Clarke, Adam

    2015-06-05

    The number of pregnant women with a body mass index (BMI) of 30kg/m(2) or more is increasing, which has important implications for antenatal care. Various resource-intensive interventions have attempted to assist women in managing their weight gain during pregnancy with limited success. A mobile phone app has been proposed as a convenient and cost-effective alternative to face-to-face interventions. This paper describes the process of developing and pilot testing the Eating4Two app, which aims to provide women with a simple gestational weight gain (GWG) calculator, general dietary information, and the motivation to achieve a healthy weight gain during pregnancy. The project involved the development of app components, including a graphing function that allows the user to record their weight throughout the pregnancy and to receive real-time feedback on weight gain progress and general information on antenatal nutrition. Stakeholder consultation was used to inform development. The app was pilot tested with 10 pregnant women using a mixed method approach via an online survey, 2 focus groups, and 1 individual interview. The Eating4Two app took 7 months to develop and evaluate. It involved several disciplines--including nutrition and dietetics, midwifery, public health, and information technology--at the University of Canberra. Participants found the Eating4Two app to be a motivational tool but would have liked scales or other markers on the graph that demonstrated exact weight gain. They also liked the nutrition information; however, many felt it should be formatted in a more user friendly way. The Eating4Two app was viewed by participants in our study as an innovative support system to help motivate healthy behaviors during pregnancy and as a credible resource for accessing nutrition-focused information. The feedback provided by participants will assist with refining the current prototype for use in a clinical intervention trial.

  7. Development of Uniform Protocol for Alopecia Areata Clinical Trials.

    PubMed

    Solomon, James A

    2015-11-01

    Developing a successful treatment for alopecia areata (AA), clearly has not been at the forefront of the agenda for new drug/device development among the pharmaceutical and medical device industry. The National Alopecia Areata Foundation (NAAF), a patient advocacy group, initiated a plan to facilitate and drive clinical research toward finding safe and efficacious treatments for AA. As such, Alopecia Areata Uniform Protocols for clinical trials to test new treatments for AA were developed. The design of the uniform protocol is to accomplish the development of a plug-and-play template as well as to provide a framework wherein data from studies utilizing the uniform protocol can be compared through consistency of inclusions/exclusions, safety, and outcome assessment measures. A core uniform protocol for use by pharmaceutical companies in testing proof of concept for investigational products to treat AA. The core protocol includes standardized title, informed consent, inclusion/exclusion criteria, disease outcome assessments, and safety assessments. The statistical methodology to assess successful outcomes will also be standardized. The protocol as well as the informed consent form has been approved in concept by Liberty IRB and is ready to present to pharmaceutical companies.

  8. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric field.

    PubMed

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-06-25

    In this study, we report experimental results on fast ICCD imaging of development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of electric field in the discharge. Uniformity of the discharge images obtained with nanosecond exposure times were analyzed using chi-square test. The results indicate that DBD uniformity strongly depends on applied (global) electric field in the discharge gap, and is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is transition from filamentary to uniform DBD mode which correlates to the corresponding decrease of maximum local electric field in the discharge.

  9. Variational optimization algorithms for uniform matrix product states

    NASA Astrophysics Data System (ADS)

    Zauner-Stauber, V.; Vanderstraeten, L.; Fishman, M. T.; Verstraete, F.; Haegeman, J.

    2018-01-01

    We combine the density matrix renormalization group (DMRG) with matrix product state tangent space concepts to construct a variational algorithm for finding ground states of one-dimensional quantum lattices in the thermodynamic limit. A careful comparison of this variational uniform matrix product state algorithm (VUMPS) with infinite density matrix renormalization group (IDMRG) and with infinite time evolving block decimation (ITEBD) reveals substantial gains in convergence speed and precision. We also demonstrate that VUMPS works very efficiently for Hamiltonians with long-range interactions and also for the simulation of two-dimensional models on infinite cylinders. The new algorithm can be conveniently implemented as an extension of an already existing DMRG implementation.

  10. Gain and Bandwidth Enhancement of Ferrite-Loaded CBS Antenna Using Material Shaping and Positioning

    NASA Astrophysics Data System (ADS)

    Askarian Amiri, Mikal

    Loading a cavity-backed slot (CBS) antenna with ferrite material and applying a biasing static magnetic field can be used to control its resonant frequency. Such a mechanism results in a frequency reconfigurable antenna. However, placing a lossy ferrite material inside the cavity can reduce the gain or negatively impact the impedance bandwidth. This thesis develops guidelines, based on a non-uniform applied magnetic field and non-uniform magnetic field internal to the ferrite specimen, for the design of ferrite-loaded CBS antennas which enhance their gain and tunable bandwidth by shaping the ferrite specimen and judiciously locating it within the cavity. To achieve these objectives, it is necessary to examine the influence of the shape and relative location of the ferrite material, and also the proximity of the ferrite specimen from the probe on the DC magnetic field and RF electric field distributions inside the cavity. The geometry of the probe and its impacts on figures-of-merit of the antenna is of interest as well. Two common cavity backed-slot antennas (rectangular and circular cross-section) were designed, and corresponding simulations and measurements were performed and compared. The cavities were mounted on 30 cm × 30 cm perfect electric conductor (PEC) ground planes and partially loaded with ferrite material. The ferrites were biased with an external magnetic field produced by either an electromagnet or permanent magnets. Simulations were performed using FEM-based commercial software, Ansys' Maxwell 3D and HFSS. Maxwell 3D is utilized to model the non-uniform DC applied magnetic field and non-uniform magnetic field internal to the ferrite specimen; HFSS however, is used to simulate and obtain the RF characteristics of the antenna. To validate the simulations they were compared with measurements performed in ASU's EM Anechoic Chamber. After many examinations using simulations and measurements, some optimal designs guidelines with respect to the gain

  11. Effect of gain contouring in erbium-doped fiber amplifiers on bit error rate performance of wavelength-division multiplexing-based radio over fiber links

    NASA Astrophysics Data System (ADS)

    Jose, Tony; Narayanan, Vijayakumar

    2018-03-01

    Radio over fiber (RoF) systems use a large number of base stations (BSs) and a number of central stations (CSs), which are interlinked together to form the network. RoF systems use multiple wavelengths for communication between CSs or between CSs and BSs to facilitate the huge amount of data traffic due to the multiple services for a large number of users. When erbium-doped fiber amplifiers (EDFAs) are used as amplifiers in such wavelength-division multiplexed systems, the nonuniform gain spectrum of EDFAs causes instability to some of the channels while providing faithful amplification to other channels. To avoid this inconsistency, the gain spectrum of the amplifier needs to be uniform along the whole usable range of wavelengths. A gain contouring technique is proposed to provide uniform gain to all channels irrespective of wavelength. Optical add/drop multiplexers (OADMs) and different lengths of erbium-doped fibers are used to create such a gain contouring mechanism in the optical domain itself. The effect of a cascade of nonuniform gain amplifiers is studied, and the proposed system mitigates the adverse effects caused due to nonuniform gain-induced channel instability effectively.

  12. Evaluating the uniformity of color spaces and performance of color difference formulae

    NASA Astrophysics Data System (ADS)

    Lian, Yusheng; Liao, Ningfang; Wang, Jiajia; Tan, Boneng; Liu, Zilong

    2010-11-01

    Using small color difference data sets (Macadam ellipses dataset and RIT-DuPont suprathreshold color difference ellipses dataset), and large color difference data sets (Munsell Renovation Data and OSA Uniform Color Scales dataset), the uniformity of several color spaces and performance of color difference formulae based on these color spaces are evaluated. The color spaces used are CIELAB, DIN99d, IPT, and CIECAM02-UCS. It is found that the uniformity of lightness is better than saturation and hue. Overall, for all these color spaces, the uniformity in the blue area is inferior to the other area. The uniformity of CIECAM02-UCS is superior to the other color spaces for the whole color-difference range from small to large. The uniformity of CIELAB and IPT for the large color difference data sets is better than it for the small color difference data sets, but the DIN99d is opposite. Two common performance factors (PF/3 and STRESS) and the statistical F-test are calculated to test the performance of color difference formula. The results show that the performance of color difference formulae based on these four color spaces is consistent with the uniformity of these color spaces.

  13. Desert Test Site Uniformity Analysis

    NASA Technical Reports Server (NTRS)

    Kerola, Dana X.; Bruegge, Carol J.

    2009-01-01

    Desert test sites such as Railroad Valley (RRV) Nevada, Egypt-1, and Libya-4 are commonly targeted to assess the on-orbit radiometric performance of sensors. Railroad Valley is used for vicarious calibration experiments, where a field-team makes ground measurements to produce accurate estimates of top-of-atmosphere (TOA) radiances. The Sahara desert test sites are not instrumented, but provide a stable target that can be used for sensor cross-comparisons, or for stability monitoring of a single sensor. These sites are of interest to NASA's Atmospheric Carbon Observation from Space (ACOS) and JAXA's Greenhouse Gas Observation SATellite (GOSAT) programs. This study assesses the utility of these three test sites to the ACOS and GOSAT calibration teams. To simulate errors in sensor-measured radiance with pointing errors, simulated data have been created using MODIS Aqua data. MODIS data are further utilized to validate the campaign data acquired from June 22 through July 5, 2009. The first GOSAT vicarious calibration experiment was conducted during this timeframe.

  14. 10 CFR Appendix M to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps M Appendix M to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. M Appendix M to Subpart B of...

  15. 10 CFR Appendix M to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps M Appendix M to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. M Appendix M to Subpart B of...

  16. 10 CFR Appendix M to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps M Appendix M to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. M Appendix M to Subpart B of...

  17. 10 CFR Appendix M to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps M Appendix M to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. M Appendix M to Subpart B of...

  18. 10 CFR Appendix M to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps M Appendix M to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. M Appendix M to Subpart B of...

  19. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric field

    PubMed Central

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-01-01

    In this study, we report experimental results on fast ICCD imaging of development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of electric field in the discharge. Uniformity of the discharge images obtained with nanosecond exposure times were analyzed using chi-square test. The results indicate that DBD uniformity strongly depends on applied (global) electric field in the discharge gap, and is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is transition from filamentary to uniform DBD mode which correlates to the corresponding decrease of maximum local electric field in the discharge. PMID:25071294

  20. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of Unvented Home Heating Equipment G Appendix G to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... gas control value (e.g., by label) by the manufacturer. 2.4 Electrical standby mode power measurement...

  1. Development and Pilot Testing of the Eating4two Mobile Phone App to Monitor Gestational Weight Gain

    PubMed Central

    Davis, Deborah Lee; Williams, Lauren; Davey, Rachel; Cox, Robert; Clarke, Adam

    2015-01-01

    Background The number of pregnant women with a body mass index (BMI) of 30kg/m2 or more is increasing, which has important implications for antenatal care. Various resource-intensive interventions have attempted to assist women in managing their weight gain during pregnancy with limited success. A mobile phone app has been proposed as a convenient and cost-effective alternative to face-to-face interventions. Objective This paper describes the process of developing and pilot testing the Eating4Two app, which aims to provide women with a simple gestational weight gain (GWG) calculator, general dietary information, and the motivation to achieve a healthy weight gain during pregnancy. Methods The project involved the development of app components, including a graphing function that allows the user to record their weight throughout the pregnancy and to receive real-time feedback on weight gain progress and general information on antenatal nutrition. Stakeholder consultation was used to inform development. The app was pilot tested with 10 pregnant women using a mixed method approach via an online survey, 2 focus groups, and 1 individual interview. Results The Eating4Two app took 7 months to develop and evaluate. It involved several disciplines--including nutrition and dietetics, midwifery, public health, and information technology--at the University of Canberra. Participants found the Eating4Two app to be a motivational tool but would have liked scales or other markers on the graph that demonstrated exact weight gain. They also liked the nutrition information; however, many felt it should be formatted in a more user friendly way. Conclusions The Eating4Two app was viewed by participants in our study as an innovative support system to help motivate healthy behaviors during pregnancy and as a credible resource for accessing nutrition-focused information. The feedback provided by participants will assist with refining the current prototype for use in a clinical intervention

  2. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of Unvented Home Heating Equipment G Appendix G to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of.... 28, 1984] Effective Date Note: At 77 FR 74571, Dec. 17, 2012, appendix G to subpart B of part 430 was...

  3. Pumping tests in non-uniform aquifers - the linear strip case

    USGS Publications Warehouse

    Butler, J.J.; Liu, W.Z.

    1991-01-01

    Many pumping tests are performed in geologic settings that can be conceptualized as a linear infinite strip of one material embedded in a matrix of differing flow properties. A semi-analytical solution is presented to aid the analysis of drawdown data obtained from pumping tests performed in settings that can be represented by such a conceptual model. Integral transform techniques are employed to obtain a solution in transform space that can be numerically inverted to real space. Examination of the numerically transformed solution reveals several interesting features of flow in this configuration. If the transmissivity of the strip is much higher than that of the matrix, linear and bilinear flow are the primary flow regimes during a pumping test. If the contrast between matrix and strip properties is not as extreme, then radial flow should be the primary flow mechanism. Sensitivity analysis is employed to develop insight into the controls on drawdown in this conceptual model and to demonstrate the importance of temporal and spatial placement of observations. Changes in drawdown are sensitive to the transmissivity of the strip for a limited time duration. After that time, only the total drawdown remains a function of strip transmissivity. In the case of storativity, both the total drawdown and changes in drawdown are sensitive to the storativity of the strip for a time of quite limited duration. After that time, essentially no information can be gained about the storage properties of the strip from drawdown data. An example analysis is performed using data previously presented in the literature to demonstrate the viability of the semi-analytical solution and to illustrate a general procedure for analysis of drawdown data in complex geologic settings. This example reinforces the importance of observation well placement and the time of data collection in constraining parameter correlation, a major source of the uncertainty that arises in the parameter estimation

  4. Noise Power Spectrum Measurements in Digital Imaging With Gain Nonuniformity Correction.

    PubMed

    Kim, Dong Sik

    2016-08-01

    The noise power spectrum (NPS) of an image sensor provides the spectral noise properties needed to evaluate sensor performance. Hence, measuring an accurate NPS is important. However, the fixed pattern noise from the sensor's nonuniform gain inflates the NPS, which is measured from images acquired by the sensor. Detrending the low-frequency fixed pattern is traditionally used to accurately measure NPS. However, detrending methods cannot remove high-frequency fixed patterns. In order to efficiently correct the fixed pattern noise, a gain-correction technique based on the gain map can be used. The gain map is generated using the average of uniformly illuminated images without any objects. Increasing the number of images n for averaging can reduce the remaining photon noise in the gain map and yield accurate NPS values. However, for practical finite n , the photon noise also significantly inflates NPS. In this paper, a nonuniform-gain image formation model is proposed and the performance of the gain correction is theoretically analyzed in terms of the signal-to-noise ratio (SNR). It is shown that the SNR is O(√n) . An NPS measurement algorithm based on the gain map is then proposed for any given n . Under a weak nonuniform gain assumption, another measurement algorithm based on the image difference is also proposed. For real radiography image detectors, the proposed algorithms are compared with traditional detrending and subtraction methods, and it is shown that as few as two images ( n=1 ) can provide an accurate NPS because of the compensation constant (1+1/n) .

  5. Do School Uniforms Fit?

    ERIC Educational Resources Information Center

    White, Kerry A.

    2000-01-01

    In 1994, Long Beach (California) Unified School District began requiring uniforms in all elementary and middle schools. Now, half of all urban school systems and many suburban schools have uniform policies. Research on uniforms' effectiveness is mixed. Tightened dress codes may be just as effective and less litigious. (MLH)

  6. Reliability and comparison of gain values with occurrence of saccades in the EyeSeeCam video head impulse test (vHIT).

    PubMed

    Korsager, Leise Elisabeth Hviid; Schmidt, Jesper Hvass; Faber, Christian; Wanscher, Jens Højberg

    2016-12-01

    The vHIT (video head impulse test) investigates the vestibular function in two ways: a VOR (vestibulo-ocular reflex) gain value and a head impulse diagram. From the diagram covert and overt saccades can be detected. Evaluation of the vestibular function based on vHIT depends on both parameters. There is a lack of knowledge regarding the reliability of the two parameters. The objective was to investigate the reliability of vHIT by comparing gain values between examiners on the same subjects, and to see how differences affected the occurrence of saccades. 25 subjects who had undergone cochlear implant (CI) surgery. Subjects were tested using the vHIT by two of four different examiners. Two judges interpreted the occurrence of saccades in the diagram. VOR gain values and the occurrence of saccades in the diagram. Differences in gain values between examiners varied from 0.2 to 0.58 with an average of 0.14 (95 % CI 0.12-0.16) on the right ear and 0.17 (95 % CI 0.15-0.19) on the left ear. Occurrences of saccades in the same patient were reproduced in 93 % of the cases by all examiners. Kappa's coefficient on the occurrence of saccades was 0.83. Interclass correlation coefficient (ICC) of the gain values between examiners ranged from 0.62 to 0.70. Differences in gain values amongst examiners did not seem to affect the occurrence of saccades in the same patient. The occurrence of saccades, therefore, seems to be more reliable than the gain value in the evaluation of the vestibular function. Interpretation of vHIT results should, therefore, first depend on the occurrence of saccades and second on the gain value.

  7. Variable gain for a wind turbine pitch control

    NASA Technical Reports Server (NTRS)

    Seidel, R. C.; Birchenough, A. G.

    1981-01-01

    The gain variation is made in the software logic of the pitch angle controller. The gain level is changed depending upon the level of power error. The control uses low gain for low pitch activity the majority of the time. If the power exceeds ten percent offset above rated, the gain is increased to a higher gain to more effectively limit power. A variable gain control functioned well in tests on the Mod-0 wind turbine.

  8. Comparison of the seafloor displacement from uniform and non-uniform slip models on tsunami simulation of the 2011 Tohoku-Oki earthquake

    NASA Astrophysics Data System (ADS)

    Ulutas, Ergin

    2013-01-01

    The numerical simulations of recent tsunami caused by 11 March 2011 off-shore Pacific coast of Tohoku-Oki earthquake (Mw 9.0) using diverse co-seismic source models have been performed. Co-seismic source models proposed by various observational agencies and scholars are further used to elucidate the effects of uniform and non-uniform slip models on tsunami generation and propagation stages. Non-linear shallow water equations are solved with a finite difference scheme, using a computational grid with different cell sizes over GEBCO30 bathymetry data. Overall results obtained and reported by various tsunami simulation models are compared together with the available real-time kinematic global positioning system (RTK-GPS) buoys, cabled deep ocean-bottom pressure gauges (OBPG), and Deep-ocean Assessment and Reporting of Tsunami (DART) buoys. The purpose of this study is to provide a brief overview of major differences between point-source and finite-fault methodologies on generation and simulation of tsunamis. Tests of the assumptions of uniform and non-uniform slip models designate that the average uniform slip models may be used for the tsunami simulations off-shore, and far from the source region. Nevertheless, the heterogeneities of the slip distribution within the fault plane are substantial for the wave amplitude in the near field which should be investigated further.

  9. Assessment of MODIS RSB Detector Uniformity Using Deep Convective Clouds

    NASA Technical Reports Server (NTRS)

    Chang, Tiejun; Xiong, Xiaoxiong (Jack); Angal, Amit; Mu, Qiaozhen

    2016-01-01

    For satellite sensor, the striping observed in images is typically associated with the relative multiple detector gain difference derived from the calibration. A method using deep convective cloud (DCC) measurements to assess the difference among detectors after calibration is proposed and demonstrated for select reflective solar bands (RSBs) of the Moderate Resolution Imaging Spectroradiometer (MODIS). Each detector of MODIS RSB is calibrated independently using a solar diffuser (SD). Although the SD is expected to accurately characterize detector response, the uncertainties associated with the SD degradation and characterization result in inadequacies in the estimation of each detector's gain. This work takes advantage of the DCC technique to assess detector uniformity and scan mirror side difference for RSB. The detector differences for Terra MODIS Collection 6 are less than 1% for bands 1, 3-5, and 18 and up to 2% for bands 6, 19, and 26. The largest difference is up to 4% for band 7. Most Aqua bands have detector differences less than 0.5% except bands 19 and 26 with up to 1.5%. Normally, large differences occur for edge detectors. The long-term trending shows seasonal oscillations in detector differences for some bands, which are correlated with the instrument temperature. The detector uniformities were evaluated for both unaggregated and aggregated detectors for MODIS band 1 and bands 3-7, and their consistencies are verified. The assessment results were validated by applying a direct correction to reflectance images. These assessments can lead to improvements to the calibration algorithm and therefore a reduction in striping observed in the calibrated imagery.

  10. Test Duration for Water Intake, Average Daily Gain, and Dry Matter Intake in Beef Cattle.

    PubMed

    Ahlberg, C M; Allwardt, K; Broocks, A; Bruno, K; McPhillips, L; Taylor, A; Krehbiel, C R; Calvo-Lorenzo, M; Richards, C J; Place, S E; DeSilva, U; VanOverbeke, D L; Mateescu, R G; Kuehn, L A; Weaber, R L; Bormann, J M; Rolf, M M

    2018-05-22

    Water is an essential nutrient, but the effect it has on performance generally receives little attention. There are few systems and guidelines for collection of water intake phenotypes in beef cattle, which makes large-scale research on water intake a challenge. The Beef Improvement Federation has established guidelines for feed intake and average daily gain tests, but no guidelines exist for water intake. The goal of this study was to determine the test duration necessary for collection of accurate water intake phenotypes. To facilitate this goal, individual daily water intake (WI) and feed intake (FI) records were collected on 578 crossbred steers for a total of 70 d using an Insentec system at the Oklahoma State University Willard Sparks Beef Research Unit. Steers were fed in 5 groups and were individually weighed every 14 days. Within each group, steers were blocked by body weight (low and high) and randomly assigned to 1 of 4 pens containing approximately 30 steers per pen. Each pen provided 103.0 m2 of shade and included an Insentec system containing 6 feed bunks and 1 water bunk. Steers were fed a constant diet across groups and dry matter intake was calculated using the average of weekly percent dry matter within group. Average feed and water intakes for each animal were computed for increasingly large test durations (7, 14, 21, 28, 35, 42, 49, 56, 63 and 70 d), and ADG was calculated using a regression formed from body weights (BW) taken every14 d (0, 14, 28, 42, 56, and 70 d). Intervals for all traits were computed starting from both the beginning (d 0) and the end of the testing period (d 70). Pearson and Spearman correlations were computed for phenotypes from each shortened test period and for the full 70-d test. Minimum test duration was determined when the Pearson correlations were greater than 0.95 for each trait. Our results indicated that minimum test duration for WI, DMI, and ADG were 35, 42, and 70 d, respectively. No comparable studies exist for

  11. Experimental Setup and Commissioning of a Test Facility for Gain Evaluation of Microchannel-Plate Photomultipliers in High Magnetic Field at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Bringley, Eric; Cao, Tongtong; Ilieva, Yordonka; Nadel-Turonski, Pawel; Park, Kijun; Zorn, Carl

    2014-09-01

    At the Thomas Jefferson National Accelerator Facility (JLab) a research and development project for a Detector of Internally-Reflected Cherenkov light for the upcoming Electron Ion Collider is underway. One goal is the development of a compact readout camera that can operate in high magnetic fields. Small-size photon sensors, such as Microchannel-Plate Photomultipliers (MCP-PMT), are key components of the readout. Here we present our work to set up and commission a dedicated test facility at JLab where MCP-PMT gain is evaluated in magnetic fields of up to 5 T, and to develop a test procedure and analysis software to determine the gain. We operate the setup in a single-photon mode, where a light-emitting diode delivers photons to the sensor's photocathode. The PMT spectrum is measured with a flash Analog-to-Digital converter (fADC). We model the spectrum as a sum of an exponential background and a convolution of Poisson and Gaussian distributions of the pedestal and multiple photoelectron peaks, respectively. We determine the PMT's gain from the position of the single-photoelectron peak obtained by fitting the fADC spectrum to the model. Our gain uncertainty is <10%. The facility is now established and will have a long-lasting value for sensor tests and beyond-nuclear-physics applications.

  12. Gain Evaluation of Micro-Channel-Plate Photomultipliers in the Upgraded High-B Test Facility at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Barber, Corinne; DIRC at EIC Collaboration

    2015-10-01

    The High-B test facility at Thomas Jefferson National Accelerator Facility allows researchers to evaluate the gain of compact photon sensors, such as Micro-Channel-Plate Photomultipliers (MCP-PMTs), in magnetic fields up to 5 T. These ongoing studies support the development of a Detector of Internally Reflected Cherenkov light (DIRC) to be used in an Electron Ion Collider (EIC). Here, we present our summer 2015 activities to upgrade and improve the facility, and we show results for MCP-PMT gain changes in high B-fields. To monitor the light stability delivered to the MCP-PMTs being tested, we implemented a Silicon Photomultiplier (SiPM) in the setup and calibrated the ADC reading this sensor. A 405-nm Light-Emitting Diode (LED) housed in an optical tube compatible with neutral density filters was also installed. The filters provide an alternative way of reducing the light output of the LED to operate the MCP-PMTs in a single-photon mode. We calibrated a set of filters by means of a photodiode and measured the photon flux at multiple positions relative to the LED. This information helped us to design 3D-printed holders unique to each MCP-PMT so that the photocathode receives the greatest amount of light. The improvements to the setup allow for more precise PMT gain evaluation. This team includes 7 collaborators/co-authors besides myself: Yordanka Ilieva, Kijun Park, Greg Kalicy, Carl Zorn, Pawel Nadel-Turonski, Tongtong Cao, and Lee.

  13. Supplemental Educational Services and Student Test Score Gains: Evidence from a Large, Urban School District. Working Paper

    ERIC Educational Resources Information Center

    Springer, Matthew G.; Pepper, Matthew J.; Ghosh-Dastidar, Bonnie

    2009-01-01

    This study examines the effect of supplemental educational services (SES) on student test score gains and whether particular subgroups of students benefit more from No Child Left Behind (NCLB) tutoring services. The sample used includes information on students enrolled in 3rd through 8th grades nested in 121 elementary and middle schools over a…

  14. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    PubMed

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  15. Design and testing of a uniformly solar energy TIR-R concentration lenses for HCPV systems.

    PubMed

    Shen, S C; Chang, S J; Yeh, C Y; Teng, P C

    2013-11-04

    In this paper, total internal reflection-refraction (TIR-R) concentration (U-TIR-R-C) lens module were designed for uniformity using the energy configuration method to eliminate hot spots on the surface of solar cell and increase conversion efficiency. The design of most current solar concentrators emphasizes the high-power concentration of solar energy, however neglects the conversion inefficiency resulting from hot spots generated by uneven distributions of solar energy concentrated on solar cells. The energy configuration method proposed in this study employs the concept of ray tracing to uniformly distribute solar energy to solar cells through a U-TIR-R-C lens module. The U-TIR-R-C lens module adopted in this study possessed a 76-mm diameter, a 41-mm thickness, concentration ratio of 1134 Suns, 82.6% optical efficiency, and 94.7% uniformity. The experiments demonstrated that the U-TIR-R-C lens module reduced the core temperature of the solar cell from 108 °C to 69 °C and the overall temperature difference from 45 °C to 10 °C, and effectively relative increased the conversion efficiency by approximately 3.8%. Therefore, the U-TIR-R-C lens module designed can effectively concentrate a large area of sunlight onto a small solar cell, and the concentrated solar energy can be evenly distributed in the solar cell to achieve uniform irradiance and effectively eliminate hot spots.

  16. Experimental verification of gain drop due to general ion recombination for a carbon-ion pencil beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tansho, Ryohei, E-mail: r-tansho@nirs.go.jp; Furukawa, Takuji; Hara, Yousuke

    Purpose: Accurate dose measurement in radiotherapy is critically dependent on correction for gain drop, which is the difference of the measured current from the ideal saturation current due to general ion recombination. Although a correction method based on the Boag theory has been employed, the theory assumes that ionized charge density in an ionization chamber (IC) is spatially uniform throughout the irradiation volume. For particle pencil beam scanning, however, the charge density is not uniform, because the fluence distribution of a pencil beam is not uniform. The aim of this study was to verify the effect of the nonuniformity ofmore » ionized charge density on the gain drop due to general ion recombination. Methods: The authors measured the saturation curve, namely, the applied voltage versus measured current, using a large plane-parallel IC and 24-channel parallel-plate IC with concentric electrodes. To verify the effect of the nonuniform ionized charge density on the measured saturation curve, the authors calculated the saturation curve using a method which takes into account the nonuniform ionized charge density and compared it with the measured saturation curves. Results: Measurement values of the different saturation curves in the different channels of the concentric electrodes differed and were consistent with the calculated values. The saturation curves measured by the large plane-parallel IC were also consistent with the calculation results, including the estimation error of beam size and of setup misalignment. Although the impact of the nonuniform ionized charge density on the gain drop was clinically negligible with the conventional beam intensity, it was expected that the impact would increase with higher ionized charge density. Conclusions: For pencil beam scanning, the assumption of the conventional Boag theory is not valid. Furthermore, the nonuniform ionized charge density affects the prediction accuracy of gain drop when the ionized charge

  17. Gravitational Influences on Flame Propagation Through Non-Uniform, Premixed Gas Systems

    NASA Technical Reports Server (NTRS)

    Miller, Fletcher J.; Easton, John; Marchese, Anthony; Hovermann, Fred

    2003-01-01

    Flame propagation through non-uniformly premixed (or layered) gases has importance both in useful combustion systems and in unintentional fires. As summarized recently and in previous Microgravity Workshop papers, non-uniform premixed gas combustion receives scant attention compared to the more usual limiting cases of diffusion or uniformly premixed flames, especially regarding the role gravity plays. This paper summarizes our recent findings on gravitational effects on layered combustion along a floor, in which the fuel concentration gradient exists normal to the direction of flame spread. In an effort to understand the mechanism by which the flames spread faster in microgravity (and much faster, in laboratory coordinates, than the laminar burning velocity for uniform mixtures), we have begun making pressure measurements across the spreading flame front that are described here. Earlier researchers, testing in 1g, claimed that hydrostatic pressure differences could account for the rapid spread rates. Additionally, we present the development of a new apparatus to study flame spread in free (i.e., far from walls), non-homogeneous fuel layers formed in a flow tunnel behind an airfoil that has been tested in normal gravity.

  18. A free-electron laser in a uniform magnetic field

    NASA Technical Reports Server (NTRS)

    Ride, S. K.; Colson, W. B.

    1979-01-01

    The study shows that a free-electron laser can operate in a uniform, longitudinal magnetic field. The fully relativistic Lorentz force equations are examined and solved order by order in a radiation field strength to obtain analytic expressions for the electron trajectory and energy as functions of initial electron position within a wavelength of light. Analytic expressions for the longitudinal and transverse bunching and for laser gain are found. The bunching of this laser process is compared to the bunching processes involved in (1) a Stanford free-electron laser and (2) a cyclotron maser. The results received can be useful in exploring light amplification in astrophysical magnetic fields, the magnetosphere, and in laboratory devices.

  19. Testing CREATE at Community Colleges: An Examination of Faculty Perspectives and Diverse Student Gains

    PubMed Central

    Kenyon, Kristy L.; Onorato, Morgan E.; Gottesman, Alan J.; Hoque, Jamila; Hoskins, Sally G.

    2016-01-01

    CREATE (Consider, Read, Elucidate the hypotheses, Analyze and interpret the data, and Think of the next Experiment) is an innovative pedagogy for teaching science through the intensive analysis of scientific literature. Initiated at the City College of New York, a minority-serving institution, and regionally expanded in the New York/New Jersey/Pennsylvania area, this methodology has had multiple positive impacts on faculty and students in science, technology, engineering, and mathematics courses. To determine whether the CREATE strategy is effective at the community college (2-yr) level, we prepared 2-yr faculty to use CREATE methodologies and investigated CREATE implementation at community colleges in seven regions of the United States. We used outside evaluation combined with pre/postcourse assessments of students to test related hypotheses: 1) workshop-trained 2-yr faculty teach effectively with the CREATE strategy in their first attempt, and 2) 2-yr students in CREATE courses make cognitive and affective gains during their CREATE quarter or semester. Community college students demonstrated positive shifts in experimental design and critical-thinking ability concurrent with gains in attitudes/self-rated learning and maturation of epistemological beliefs about science. PMID:26931399

  20. Highly Tunable Hollow Gold Nanospheres: Gaining Size Control and Uniform Galvanic Exchange of Sacrificial Cobalt Boride Scaffolds.

    PubMed

    Lindley, Sarah A; Cooper, Jason K; Rojas-Andrade, Mauricio D; Fung, Victoria; Leahy, Conor J; Chen, Shaowei; Zhang, Jin Z

    2018-04-18

    In principle, the diameter and surface plasmon resonance (SPR) frequency of hollow metal nanostructures can be independently adjusted, allowing the formation of targeted photoactivated structures of specific size and optical functionality. Although tunable SPRs have been reported for various systems, the shift in SPR is usually concomitant with a change in particle size. As such, more advanced tunability, including constant diameter with varying SPR or constant SPR with varying diameter, has not been properly achieved experimentally. Herein, we demonstrate this advanced tunability with hollow gold nanospheres (HGNs). HGNs were synthesized through galvanic exchange using cobalt-based nanoparticles (NPs) as sacrificial scaffolds. Co 2 B NP scaffolds were prepared by sodium borohydride nucleation of aqueous cobalt chloride and characterized using UV-vis, dynamic light scattering, X-ray absorption spectroscopy, and X-ray photoelectron spectroscopy. Careful control over the size of the Co 2 B scaffold and its galvanic conversion is essential to realize fine control of the resultant HGN diameter and shell thickness. In pursuit of size control, we introduce B(OH) 4 - (the final product of NaBH 4 hydrolysis) as a growth agent to obtain hydrodynamic diameters ranging from ∼17-85 nm with relative standard deviation <3%. The highly monodisperse Co 2 B NPs were then used as scaffolds for the formation of HGNs. In controlling HGN shell thickness and uniformity, environmental oxygen was shown to affect both the structural and optical properties of the resultant gold shells. With careful control of these key factors, we demonstrate an HGN synthesis that enables independent variation of diameter and shell thickness, and thereby SPR, with unprecedented uniformity. The new synthesis method creates a truly tunable plasmonic nanostructure platform highly desirable for a wide range of applications, including sensing, catalysis, and photothermal therapy.

  1. A novel "gain chip" concept for high-power lasers (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Li, Min; Li, Mingzhong; Wang, Zhenguo; Yan, Xiongwei; Jiang, Xinying; Zheng, Jiangang; Cui, Xudong; Zhang, Xiaomin

    2017-05-01

    High-power lasers, including high-peak power lasers (HPPL) and high-average power lasers (HAPL), attract much interest for enormous variety of applications in inertial fusion energy (IFE), materials processing, defense, spectroscopy, and high-field physics research. To meet the requirements of high efficiency and quality, a "gain chip" concept is proposed to properly design the pumping, cooling and lasing fields. The gain chip mainly consists of the laser diode arrays, lens duct, rectangle wave guide and slab-shaped gain media. For the pumping field, the pump light will be compressed and homogenized by the lens duct to high irradiance with total internal reflection, and further coupled into the gain media through its two edge faces. For the cooling field, the coolant travels along the flow channel created by the adjacent slabs in the other two edge-face direction, and cool the lateral faces of the gain media. For the lasing field, the laser beam travels through the lateral faces and experiences minimum thermal wavefront distortions. Thereby, these three fields are in orthogonality offering more spatial freedom to handle them during the construction of the lasers. Transverse gradient doping profiles for HPPL and HAPL have been employed to achieve uniform gain distributions (UGD) within the gain media, respectively. This UGD will improve the management for both amplified spontaneous emission (ASE) and thermal behavior. Since each "gain chip" has its own pump source, power scaling can be easily achieved by placing identical "gain chips" along the laser beam axis without disturbing the gain and thermal distributions. To detail our concept, a 1-kJ pulsed amplifier is designed and optical-to-optical efficiency up to 40% has been obtained. We believe that with proper coolant (gas or liquid) and gain media (Yb:YAG, Nd:glass or Nd:YAG) our "gain chip" concept might provide a general configuration for high-power lasers with high efficiency and quality.

  2. Analysis of Uniform Random Numbers Generated by Randu and Urn Ten Different Seeds.

    DTIC Science & Technology

    The statistical properties of the numbers generated by two uniform random number generators, RANDU and URN, each using ten different seeds are...The testing is performed on a sequence of 50,000 numbers generated by each uniform random number generator using each of the ten seeds . (Author)

  3. Nurses’ uniforms: How many bacteria do they carry after one shift?

    PubMed Central

    Sanon, Marie-Anne; Watkins, Sally

    2013-01-01

    This pilot study investigated the pathogens that nurses are potentially bringing into the public and their home when they wear work uniforms outside of the work environment. To achieve this, sterilized uniforms were distributed to 10 nurses at a local hospital in Washington State at the beginning of their shift. Worn uniforms were collected at the end of the shifts and sent to a laboratory for analysis. Four tests were conducted: 1) a heterotrophic growth plate count, 2) methicillin-resistant Staphylococcus aureus (MRSA) growth, 3) vancomycin-resistant Enterococci (VRE), and 4) identification of the heterotrophic plate counts. Each participant completed a questionnaire and a survey. The results showed that the average bacteria colony growth per square inch was 1,246 and 5,795 for day and night shift, respectively. After 48 h, MRSA positives were present on 4 of the day shift and 3 of the night shift uniforms. Additional bacteria identified include: Bacillus sp., Micrococcus luteus, Staphylococcus aureus, Staphylococcus epidermidis, and Micrococcus roseus. The significant presence of bacteria on the uniforms 48 h after the shift ended necessitates further study, discussions and policy consideration regarding wearing health care uniforms outside of the work environment. PMID:25285235

  4. Nurses' uniforms: How many bacteria do they carry after one shift?

    PubMed

    Sanon, Marie-Anne; Watkins, Sally

    2012-12-01

    This pilot study investigated the pathogens that nurses are potentially bringing into the public and their home when they wear work uniforms outside of the work environment. To achieve this, sterilized uniforms were distributed to 10 nurses at a local hospital in Washington State at the beginning of their shift. Worn uniforms were collected at the end of the shifts and sent to a laboratory for analysis. Four tests were conducted: 1) a heterotrophic growth plate count, 2) methicillin-resistant Staphylococcus aureus (MRSA) growth, 3) vancomycin-resistant Enterococci (VRE), and 4) identification of the heterotrophic plate counts. Each participant completed a questionnaire and a survey. The results showed that the average bacteria colony growth per square inch was 1,246 and 5,795 for day and night shift, respectively. After 48 h, MRSA positives were present on 4 of the day shift and 3 of the night shift uniforms. Additional bacteria identified include: Bacillus sp., Micrococcus luteus, Staphylococcus aureus, Staphylococcus epidermidis, and Micrococcus roseus. The significant presence of bacteria on the uniforms 48 h after the shift ended necessitates further study, discussions and policy consideration regarding wearing health care uniforms outside of the work environment.

  5. Setup of a photomultiplier tube test bench for LHAASO-KM2A

    NASA Astrophysics Data System (ADS)

    Wang, Xu; Zhang, Zhong-Quan; Tian, Ye; Du, Yan-Yan; Zhao, Xiao; Shen, Fu-Wang; Li, Chang-Yu; Sun, Yan-Sheng; Feng, Cun-Feng

    2016-08-01

    To fulfill the requirements for testing the photomultiplier tubes (PMTs) of the electromagnetic detector at the Large High Altitude Air Shower Observatory (LHAASO), a multi-functional PMT test bench with a two-dimensional scanning system has been developed. With this 2D scanning system, 16 PMTs can be scanned simultaneously for characteristics tests, including uniformity, cathode transit time difference, single photo-electron spectrum, gain vs. high voltage, linear behavior and dark noise. The programmable hardware and intelligent software of the test bench make it convenient to use and provide reliable results. The test methods are described in detail and primary results are presented. Supported by NSFC (11075096) SDNFS (ZR2011AM007), China

  6. Optimal PID gain schedule for hydrogenerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orelind, G.; Wozniak, L.; Medanic, J.

    1989-09-01

    This paper describes the development and testing of a digital gain switching governor for hydrogenerators. Optimal gains were found at different load points by minimizing a quadratic performance criterion prior to controller operating. During operation, the gain sets are switched in depending on the gate position and speed error magnitude. With gain switching operating, the digital governor was shown to have a substantial reduction of noise on the command signal and up to 42% faster responses to power requests. Non-linear control strategies enabled the digital governor to have a 2.5% to 2% reduction in speed overshoot on startups, and anmore » 8% to 1% reduction in undershoot on load rejections as compared to the analog.« less

  7. Non-uniformity calibration for MWIR polarization imagery obtained with integrated microgrid polarimeters

    NASA Astrophysics Data System (ADS)

    Liu, Hai-Zheng; Shi, Ze-Lin; Feng, Bin; Hui, Bin; Zhao, Yao-Hong

    2016-03-01

    Integrating microgrid polarimeters on focal plane array (FPA) of an infrared detector causes non-uniformity of polarization response. In order to reduce the effect of polarization non-uniformity, this paper constructs an experimental setup for capturing raw flat-field images and proposes a procedure for acquiring non-uniform calibration (NUC) matrix and calibrating raw polarization images. The proposed procedure takes the incident radiation as a polarization vector and offers a calibration matrix for each pixel. Both our matrix calibration and two-point calibration are applied to our mid-wavelength infrared (MWIR) polarization imaging system with integrated microgrid polarimeters. Compared with two point calibration, our matrix calibration reduces non-uniformity by 30 40% under condition of flat-field data test with polarization. The ourdoor scene observation experiment indicates that our calibration can effectively reduce polarization non-uniformity and improve the image quality of our MWIR polarization imaging system.

  8. Parafoveal Target Detectability Reversal Predicted by Local Luminance and Contrast Gain Control

    NASA Technical Reports Server (NTRS)

    Ahumada, Albert J., Jr.; Beard, Bettina L.; Null, Cynthia H. (Technical Monitor)

    1996-01-01

    This project is part of a program to develop image discrimination models for the prediction of the detectability of objects in a range of backgrounds. We wanted to see if the models could predict parafoveal object detection as well as they predict detection in foveal vision. We also wanted to make our simplified models more general by local computation of luminance and contrast gain control. A signal image (0.78 x 0.17 deg) was made by subtracting a simulated airport runway scene background image (2.7 deg square) from the same scene containing an obstructing aircraft. Signal visibility contrast thresholds were measured in a fully crossed factorial design with three factors: eccentricity (0 deg or 4 deg), background (uniform or runway scene background), and fixed-pattern white noise contrast (0%, 5%, or 10%). Three experienced observers responded to three repetitions of 60 2IFC trials in each condition and thresholds were estimated by maximum likelihood probit analysis. In the fovea the average detection contrast threshold was 4 dB lower for the runway background than for the uniform background, but in the parafovea, the average threshold was 6 dB higher for the runway background than for the uniform background. This interaction was similar across the different noise levels and for all three observers. A likely reason for the runway background giving a lower threshold in the fovea is the low luminance near the signal in that scene. In our model, the local luminance computation is controlled by a spatial spread parameter. When this parameter and a corresponding parameter for the spatial spread of contrast gain were increased for the parafoveal predictions, the model predicts the interaction of background with eccentricity.

  9. 46 CFR 310.11 - Cadet uniforms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for State, Territorial or Regional Maritime Academies and Colleges § 310.11 Cadet uniforms. Cadet uniforms shall be supplied at the school in accordance with the uniform regulations of the School. Those... 46 Shipping 8 2010-10-01 2010-10-01 false Cadet uniforms. 310.11 Section 310.11 Shipping MARITIME...

  10. 46 CFR 310.11 - Cadet uniforms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... for State, Territorial or Regional Maritime Academies and Colleges § 310.11 Cadet uniforms. Cadet uniforms shall be supplied at the school in accordance with the uniform regulations of the School. Those... 46 Shipping 8 2011-10-01 2011-10-01 false Cadet uniforms. 310.11 Section 310.11 Shipping MARITIME...

  11. 46 CFR 310.11 - Cadet uniforms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... for State, Territorial or Regional Maritime Academies and Colleges § 310.11 Cadet uniforms. Cadet uniforms shall be supplied at the school in accordance with the uniform regulations of the School. Those... 46 Shipping 8 2013-10-01 2013-10-01 false Cadet uniforms. 310.11 Section 310.11 Shipping MARITIME...

  12. 46 CFR 310.11 - Cadet uniforms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... for State, Territorial or Regional Maritime Academies and Colleges § 310.11 Cadet uniforms. Cadet uniforms shall be supplied at the school in accordance with the uniform regulations of the School. Those... 46 Shipping 8 2012-10-01 2012-10-01 false Cadet uniforms. 310.11 Section 310.11 Shipping MARITIME...

  13. 46 CFR 310.11 - Cadet uniforms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... for State, Territorial or Regional Maritime Academies and Colleges § 310.11 Cadet uniforms. Cadet uniforms shall be supplied at the school in accordance with the uniform regulations of the School. Those... 46 Shipping 8 2014-10-01 2014-10-01 false Cadet uniforms. 310.11 Section 310.11 Shipping MARITIME...

  14. Comparison of two leading uniform theories of edge diffraction with the exact uniform asymptotic solution

    NASA Technical Reports Server (NTRS)

    Boersma, J.; Rahmat-Samii, Y.

    1980-01-01

    The diffraction of an arbitrary cylindrical wave by a half-plane has been treated by Rahmat-Samii and Mittra who used a spectral domain approach. In this paper, their exact solution for the total field is expressed in terms of a new integral representation. For large wave number k, two rigorous procedures are described for the exact uniform asymptotic expansion of the total field solution. The uniform expansions obtained are valid in the entire space, including transition regions around the shadow boundaries. The final results are compared with the formulations of two leading uniform theories of edge diffraction, namely, the uniform asymptotic theory and the uniform theory of diffraction. Some unique observations and conclusions are made in relating the two theories.

  15. Should School Nurses Wear Uniforms?

    ERIC Educational Resources Information Center

    Journal of School Health, 2001

    2001-01-01

    This 1958 paper questions whether school nurses should wear uniforms (specifically, white uniforms). It concludes that white uniforms are often associated with the treatment of ill people, and since many people have a fear reaction to them, they are not necessary and are even undesirable. Since school nurses are school staff members, they should…

  16. High-Gain High-Field Fusion Plasma

    PubMed Central

    Li, Ge

    2015-01-01

    A Faraday wheel (FW)—an electric generator of constant electrical polarity that produces huge currents—could be implemented in an existing tokamak to study high-gain high-field (HGHF) fusion plasma, such as the Experimental Advanced Superconducting Tokamak (EAST). HGHF plasma can be realized in EAST by updating its pulsed-power system to compress plasma in two steps by induction fields; high gains of the Lawson trinity parameter and fusion power are both predicted by formulating the HGHF plasma. Both gain rates are faster than the decrease rate of the plasma volume. The formulation is checked by earlier ATC tests. Good agreement between theory and tests indicates that scaling to over 10 T at EAST may be possible by two-step compressions with a compression ratio of the minor radius of up to 3. These results point to a quick new path of fusion plasma study, i.e., simulating the Sun by EAST. PMID:26507314

  17. The Uniform Data System for Medical Rehabilitation

    PubMed Central

    Graham, James E.; Granger, Carl V.; Karmarkar, Amol M.; Deutsch, Anne; Niewczyk, Paulette; DiVita, Margaret A.; Ottenbacher, Kenneth J.

    2013-01-01

    Objective Present yearly aggregated summaries of rehabilitation outcomes at admission, discharge, and follow-up from a national sample of patients receiving inpatient medical rehabilitation for stroke, traumatic brain injury, lower extremity fracture, lower extremity joint replacement, traumatic spinal cord injury, or debility. Design Analysis of secondary data from more than 300 inpatient rehabilitation facilities in the United States that contributed inpatient and follow-up data to the Uniform Data System for Medical Rehabilitation during the period January 2002 through December 2010. Aggregate variables reported include demographic information, social situation, and functional status (FIM® instrument ratings at admission, discharge, and follow-up). Follow-up data were obtained 80–180 days post-discharge through telephone interviews by trained clinical staff. Results The final sample included 287,104 patients with follow-up information. Median time to follow-up was 95 days. Overall, more than 90% of patients within each impairment group were living in the community at follow-up. Follow-up FIM total ratings were stable to slightly increased over time. Change scores (discharge to follow-up) increased in all six groups. Mean FIM gains from discharge to follow-up, as a percentage of mean gains from admission to discharge, varied by impairment category: 46% for spinal cord injury to 71% for lower extremity fracture. Locomotion yielded the lowest ratings at all three assessments within each of the six impairment groups. Conclusions Follow-up data from a national sample of patients discharged from inpatient rehabilitation indicate that gains in mean functional independence scores from both admission to discharge and discharge to follow-up gradually increased from 2002 to 2010. At follow-up, more than 9 out of 10 patients in all 6 groups are living in the community. PMID:24088780

  18. AN AUTOMATED SYSTEM FOR PRODUCING UNIFORM SURFACE DEPOSITS OF DRY PARTICLES

    EPA Science Inventory

    A laboratory system has been constructed that uniformly deposits dry particles onto any type of test surface. Devised as a quality assurance tool for the purpose of evaluating surface sampling methods for lead, it also may be used to generate test surfaces for any contaminant ...

  19. Magnetostatic Field System for Uniform Cell Cultures Exposure

    PubMed Central

    Vergallo, Cristian; Piccoli, Claudia; Romano, Alberto; Panzarini, Elisa; Serra, Antonio; Manno, Daniela; Dini, Luciana

    2013-01-01

    The aim of the present work has been the design and the realization of a Magnetostatic Field System for Exposure of Cell cultures (MaFiSEC) for the uniform and the reproducible exposure of cell cultures to static magnetic fields (SMFs) of moderate magnetic induction. Experimental and computer-simulated physical measurements show that MaFiSEC: i) generates a SMF with magnetic induction that can be chosen in the range of 3 to 20 mT; ii) allows the uniform SMF exposure of cells growing in adhesion and in suspension; iii) is cheap and easy to use. The efficacy and reproducibility of MaFiSEC has been tested by comparing the biological effects exerted on isolated human lymphocytes by 72 h of exposure to a magnet (i.e. Neodymium Magnetic Disk, NMD) placed under the culture Petri dish. Lymphocytes morphology, viability, cell death, oxidative stress and lysosomes activity were the parameters chosen to evaluate the SMF biological effects. The continuous exposure of cells to a uniform SMF, achieved with MaFiSEC, allows highly reproducible biochemical and morphological data. PMID:23977284

  20. Measuring learning gain: Comparing anatomy drawing screencasts and paper-based resources.

    PubMed

    Pickering, James D

    2017-07-01

    The use of technology-enhanced learning (TEL) resources is now a common tool across a variety of healthcare programs. Despite this popular approach to curriculum delivery there remains a paucity in empirical evidence that quantifies the change in learning gain. The aim of the study was to measure the changes in learning gain observed with anatomy drawing screencasts in comparison to a traditional paper-based resource. Learning gain is a widely used term to describe the tangible changes in learning outcomes that have been achieved after a specific intervention. In regard to this study, a cohort of Year 2 medical students voluntarily participated and were randomly assigned to either a screencast or textbook group to compare changes in learning gain across resource type. Using a pre-test/post-test protocol, and a range of statistical analyses, the learning gain was calculated at three test points: immediate post-test, 1-week post-test and 4-week post-test. Results at all test points revealed a significant increase in learning gain and large effect sizes for the screencast group compared to the textbook group. Possible reasons behind the difference in learning gain are explored by comparing the instructional design of both resources. Strengths and weaknesses of the study design are also considered. This work adds to the growing area of research that supports the effective design of TEL resources which are complimentary to the cognitive theory of multimedia learning to achieve both an effective and efficient learning resource for anatomical education. Anat Sci Educ 10: 307-316. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  1. The uniformity and imaging properties of some new ceramic scintillators

    NASA Astrophysics Data System (ADS)

    Chac, George T. L.; Miller, Brian W.; Shah, Kanai; Baldoni, Gary; Domanik, Kenneth J.; Bora, Vaibhav; Cherepy, Nerine J.; Seeley, Zachary; Barber, H. Bradford

    2012-10-01

    Results are presented of investigations into the composition, uniformity and gamma-ray imaging performance of new ceramic scintillators with synthetic garnet structure. The ceramic scintillators were produced by a process that uses flame pyrolysis to make nanoparticles which are sintered into a ceramic and then compacted by hot isostatic compression into a transparent material. There is concern that the resulting ceramic scintillator might not have the uniformity of composition necessary for use in gamma-ray spectroscopy and gamma-ray imaging. The compositional uniformity of four samples of three ceramic scintillator types (GYGAG:Ce, GLuGAG:Ce and LuAG:Pr) was tested using an electron microprobe. It was found that all samples were uniform in elemental composition to the limit of sensitivity of the microprobe (few tenths of a percent atomic) over distance scales from ~ 1 cm to ~ 1 um. The light yield and energy resolution of all ceramic scintillator samples were mapped with a highly collimated 57Co source (122 keV) and performance was uniform at mapping scale of 0.25 mm. Good imaging performance with single gamma-ray photon detection was demonstrated for all samples using a BazookaSPECT system, and the imaging spatial resolution, measured as the FWHM of a LSF was 150 um.

  2. Uniform Media Effects and Uniform Audience Responses.

    ERIC Educational Resources Information Center

    Perry, David K.

    The idea that mass communication effects may decrease diversity among people or societies exposed to it arises constantly. However, discussions of mass media effects do not highlight differences between mass communications that "affect" people uniformly and messages that members of audiences "respond to" in similar ways. A…

  3. Analysis of Basis Weight Uniformity of Microfiber Nonwovens and Its Impact on Permeability and Filtration Properties

    NASA Astrophysics Data System (ADS)

    Amirnasr, Elham

    uniformity index of meltblown and spunbond samples was measured. Results for filtration test show some deviation between theoretical and experimental filtration efficiency by considering different types of fiber diameter. This deviation can occur due to variation in basis weight non-uniformity. So an appropriate theory is required to predict the variation of filtration efficiency with respect to non-uniformity of nonwoven filter media. And the results for air permeability test showed that uniformity index determined by quadrant method and measured properties have some relationship. In the other word, air permeability decreases as uniformity index on nonwoven web increase.

  4. MWPC prototyping and performance test for the STAR inner TPC upgrade

    NASA Astrophysics Data System (ADS)

    Shen, Fuwang; Wang, Shuai; Kong, Fangang; Bai, Shiwei; Li, Changyu; Videbæk, Flemming; Xu, Zhangbu; Zhu, Chengguang; Xu, Qinghua; Yang, Chi

    2018-07-01

    A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6% and wire pitch precision better than 10 μm. The gas gain uniformity and energy resolution are measured to be better than 1% (RMS) and 20% (FWHM), respectively, using an 55Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. The test results show that the constructed iTPC prototype meets all project requirements.

  5. L∞-gain adaptive fuzzy fault accommodation control design for nonlinear time-delay systems.

    PubMed

    Wu, Huai-Ning; Qiang, Xiao-Hong; Guo, Lei

    2011-06-01

    In this paper, an adaptive fuzzy fault accommodation (FA) control design with a guaranteed L(∞)-gain performance is developed for a class of nonlinear time-delay systems with persistent bounded disturbances. Using the Lyapunov technique and the Razumikhin-type lemma, the existence condition of the L(∞) -gain adaptive fuzzy FA controllers is provided in terms of linear matrix inequalities (LMIs). In the proposed FA scheme, a fuzzy logic system is employed to approximate the unknown term in the derivative of the Lyapunov function due to the unknown fault function; a continuous-state feedback control strategy is adopted for the control design to avoid the undesirable chattering phenomenon. The resulting FA controllers can ensure that every response of the closed-loop system is uniformly ultimately bounded with a guaranteed L(∞)-gain performance in the presence of a fault. Moreover, by the existing LMI optimization technique, a suboptimal controller is obtained in the sense of minimizing an upper bound of the L(∞)-gain. Finally, the achieved simulation results on the FA control of a continuous stirred tank reactor (CSTR) show the effectiveness of the proposed design procedure.

  6. A kinetic theory treatment of heat transfer in plane Poiseuille flow with uniform pressure

    NASA Technical Reports Server (NTRS)

    Bahrami, Parviz A.

    1992-01-01

    Plane compressible Poiseuille flow with uniform pressure (Couette flow with stationary boundaries) is revisited where the Lees two-steam method with the Enskog equation of change is applied. Single particle velocity distribution functions are chosen, which preserve the essential physical features of this flow with arbitrary but uniform plate temperatures and gas pressure. Lower moments are shown to lead to expressions for the parameter functions, molecular number densities, and temperatures which are entirely in agreement with those obtained in the analysis of Lees for compressible plane Couette flow in the limit of low Mach number and vanishing mean gas velocity. Important simplifications result, which are helpful in gaining insight into the power of kinetic theory in fluid mechanics. The temperature distribution, heat flux, as well as density, are completely determined for the whole range of Knudson numbers from free molecular flow to the continuum regime, when the pressure level is specified.

  7. SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghebremedhin, A; Taber, M; Koss, P

    2016-06-15

    Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability andmore » accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.« less

  8. The Video Head Impulse Test (vHIT) of Semicircular Canal Function - Age-Dependent Normative Values of VOR Gain in Healthy Subjects.

    PubMed

    McGarvie, Leigh A; MacDougall, Hamish G; Halmagyi, G Michael; Burgess, Ann M; Weber, Konrad P; Curthoys, Ian S

    2015-01-01

    The video Head Impulse Test (vHIT) is now widely used to test the function of each of the six semicircular canals individually by measuring the eye rotation response to an abrupt head rotation in the plane of the canal. The main measure of canal adequacy is the ratio of the eye movement response to the head movement stimulus, i.e., the gain of the vestibulo-ocular reflex (VOR). However, there is a need for normative data about how VOR gain is affected by age and also by head velocity, to allow the response of any particular patient to be compared to the responses of healthy subjects in their age range. In this study, we determined for all six semicircular canals, normative values of VOR gain, for each canal across a range of head velocities, for healthy subjects in each decade of life. The VOR gain was measured for all canals across a range of head velocities for at least 10 healthy subjects in decade age bands: 10-19, 20-29, 30-39, 40-49, 50-59, 60-69, 70-79, 80-89. The compensatory eye movement response to a small, unpredictable, abrupt head rotation (head impulse) was measured by the ICS impulse prototype system. The same operator delivered every impulse to every subject. Vestibulo-ocular reflex gain decreased at high head velocities, but was largely unaffected by age into the 80- to 89-year age group. There were some small but systematic differences between the two directions of head rotation, which appear to be largely due to the fact that in this study only the right eye was measured. The results are considered in relation to recent evidence about the effect of age on VOR performance. These normative values allow the results of any particular patient to be compared to the values of healthy people in their age range and so allow, for example, detection of whether a patient has a bilateral vestibular loss. VOR gain, as measured directly by the eye movement response to head rotation, seems largely unaffected by aging.

  9. A web-based normative calculator for the uniform data set (UDS) neuropsychological test battery.

    PubMed

    Shirk, Steven D; Mitchell, Meghan B; Shaughnessy, Lynn W; Sherman, Janet C; Locascio, Joseph J; Weintraub, Sandra; Atri, Alireza

    2011-11-11

    With the recent publication of new criteria for the diagnosis of preclinical Alzheimer's disease (AD), there is a need for neuropsychological tools that take premorbid functioning into account in order to detect subtle cognitive decline. Using demographic adjustments is one method for increasing the sensitivity of commonly used measures. We sought to provide a useful online z-score calculator that yields estimates of percentile ranges and adjusts individual performance based on sex, age and/or education for each of the neuropsychological tests of the National Alzheimer's Coordinating Center Uniform Data Set (NACC, UDS). In addition, we aimed to provide an easily accessible method of creating norms for other clinical researchers for their own, unique data sets. Data from 3,268 clinically cognitively-normal older UDS subjects from a cohort reported by Weintraub and colleagues (2009) were included. For all neuropsychological tests, z-scores were estimated by subtracting the raw score from the predicted mean and then dividing this difference score by the root mean squared error term (RMSE) for a given linear regression model. For each neuropsychological test, an estimated z-score was calculated for any raw score based on five different models that adjust for the demographic predictors of SEX, AGE and EDUCATION, either concurrently, individually or without covariates. The interactive online calculator allows the entry of a raw score and provides five corresponding estimated z-scores based on predictions from each corresponding linear regression model. The calculator produces percentile ranks and graphical output. An interactive, regression-based, normative score online calculator was created to serve as an additional resource for UDS clinical researchers, especially in guiding interpretation of individual performances that appear to fall in borderline realms and may be of particular utility for operationalizing subtle cognitive impairment present according to the newly

  10. Visual signal detection in structured backgrounds. II. Effects of contrast gain control, background variations, and white noise

    NASA Technical Reports Server (NTRS)

    Eckstein, M. P.; Ahumada, A. J. Jr; Watson, A. B.

    1997-01-01

    Studies of visual detection of a signal superimposed on one of two identical backgrounds show performance degradation when the background has high contrast and is similar in spatial frequency and/or orientation to the signal. To account for this finding, models include a contrast gain control mechanism that pools activity across spatial frequency, orientation and space to inhibit (divisively) the response of the receptor sensitive to the signal. In tasks in which the observer has to detect a known signal added to one of M different backgrounds grounds due to added visual noise, the main sources of degradation are the stochastic noise in the image and the suboptimal visual processing. We investigate how these two sources of degradation (contrast gain control and variations in the background) interact in a task in which the signal is embedded in one of M locations in a complex spatially varying background (structured background). We use backgrounds extracted from patient digital medical images. To isolate effects of the fixed deterministic background (the contrast gain control) from the effects of the background variations, we conduct detection experiments with three different background conditions: (1) uniform background, (2) a repeated sample of structured background, and (3) different samples of structured background. Results show that human visual detection degrades from the uniform background condition to the repeated background condition and degrades even further in the different backgrounds condition. These results suggest that both the contrast gain control mechanism and the background random variations degrade human performance in detection of a signal in a complex, spatially varying background. A filter model and added white noise are used to generate estimates of sampling efficiencies, an equivalent internal noise, an equivalent contrast-gain-control-induced noise, and an equivalent noise due to the variations in the structured background.

  11. Side-polished fiber based gain-flattening filter for erbium doped fiber amplifiers

    NASA Astrophysics Data System (ADS)

    Varshney, R. K.; Singh, A.; Pande, K.; Pal, B. P.

    2007-03-01

    A simple and accurate novel normal mode analysis has been developed to take into account the effect of the non-uniform depth of polishing in the study of the transmission characteristics of optical waveguide devices based on loading of a side-polished fiber half-coupler with a multimode planar waveguide. We apply the same to design and fabricate a gain-flattening filter suitable for fiber amplifiers. The wavelength dependent filtering action of the overall device could demonstrate flattening of an EDFA gain spectrum within ±0.7 dB over a bandwidth of 30 nm in the C-band. Results obtained by the present analysis agree very well with our experimental results. This present analysis should be very useful in the accurate design and analysis of any SPF-MMOW device/component including side-polished fiber based sensors.

  12. Assessing Success on the Uniform CPA Exam: A Logit Approach.

    ERIC Educational Resources Information Center

    Brahmasrene, Tantatape; Whitten, Donna

    2001-01-01

    A logit model was used to test the likelihood of success of 231 candidates on the Uniform Certified Public Accountants Examination. Significant determinants of success included undergraduate grade point average, age, private accounting experience, and gender. (SK)

  13. Determination of the conversion gain and the accuracy of its measurement for detector elements and arrays

    NASA Astrophysics Data System (ADS)

    Beecken, B. P.; Fossum, E. R.

    1996-07-01

    Standard statistical theory is used to calculate how the accuracy of a conversion-gain measurement depends on the number of samples. During the development of a theoretical basis for this calculation, a model is developed that predicts how the noise levels from different elements of an ideal detector array are distributed. The model can also be used to determine what dependence the accuracy of measured noise has on the size of the sample. These features have been confirmed by experiment, thus enhancing the credibility of the method for calculating the uncertainty of a measured conversion gain. detector-array uniformity, charge coupled device, active pixel sensor.

  14. Spectrofluorimetric determination of thioridazine and flupentixol in dosage forms; application to content uniformity test.

    PubMed

    Attia, Tamer Z; Omar, Mahmoud A

    2016-08-01

    A reliable, sensitive, cheap and non-extractive spectrofluorimetric method has been developed and validated for determination of thioridazine and flupentixol based on ternary complex formation with eosin and lead(II) in the presence of methylcellulose as surfactant at pH 3.2. Under the optimum conditions, the quantitative quenching effect of investigated drugs on the native fluorescence of eosin has been investigated. The quenching of the eosin fluorescence was measured at 517 nm after excitation at 462 nm. The different experimental parameters affecting the development and stability of the reaction products were carefully studied and optimized, and the results were satisfactory. The calibration plots were constructed over the range of 0.5-3.0 µg mL(-1) . The developed method was successfully applied for determination of investigated drugs in commercial tablets without interference from common excipients. It was further applied for content uniformity testing of flupentixol in its tablets. Statistical comparisons of the results with those of the reference methods revealed excellent agreement and indicated no significant difference in accuracy and precision. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Dress Codes and Uniforms.

    ERIC Educational Resources Information Center

    Lumsden, Linda; Miller, Gabriel

    2002-01-01

    Students do not always make choices that adults agree with in their choice of school dress. Dress-code issues are explored in this Research Roundup, and guidance is offered to principals seeking to maintain a positive school climate. In "Do School Uniforms Fit?" Kerry White discusses arguments for and against school uniforms and summarizes the…

  16. School Uniforms. Research Brief

    ERIC Educational Resources Information Center

    Walker, Karen

    2007-01-01

    Does clothing make the person or does the person make the clothing? How does what attire a student wears to school affect their academic achievement? In 1996, President Clinton cited examples of school violence and discipline issues that might have been avoided had the students been wearing uniforms ("School uniforms: Prevention or suppression?").…

  17. Energy gain calculations in Penning fusion systems using a bounce-averaged Fokker-Planck model

    NASA Astrophysics Data System (ADS)

    Chacón, L.; Miley, G. H.; Barnes, D. C.; Knoll, D. A.

    2000-11-01

    In spherical Penning fusion devices, a spherical cloud of electrons, confined in a Penning-like trap, creates the ion-confining electrostatic well. Fusion energy gains for these systems have been calculated in optimistic conditions (i.e., spherically uniform electrostatic well, no collisional ion-electron interactions, single ion species) using a bounce-averaged Fokker-Planck (BAFP) model. Results show that steady-state distributions in which the Maxwellian ion population is dominant correspond to lowest ion recirculation powers (and hence highest fusion energy gains). It is also shown that realistic parabolic-like wells result in better energy gains than square wells, particularly at large well depths (>100 kV). Operating regimes with fusion power to ion input power ratios (Q-value) >100 have been identified. The effect of electron losses on the Q-value has been addressed heuristically using a semianalytic model, indicating that large Q-values are still possible provided that electron particle losses are kept small and well depths are large.

  18. Problems with IQ Gains: The Huge Vocabulary Gap

    ERIC Educational Resources Information Center

    Flynn, James R.

    2010-01-01

    Despite Kaufman, Raven's Progressive Matrices and the Wechsler subtest Similarities are tests whose gains call for special explanation. The spread of "scientific spectacles" is the key, but its explanatory potential has been exhausted. Three trends force us to look elsewhere: (a) gains on Wechsler subtests such as Picture Arrangement,…

  19. Low-Gain Circularly Polarized Antenna with Torus-Shaped Pattern

    NASA Technical Reports Server (NTRS)

    Amaro, Luis R.; Kruid, Ronald C.; Vacchione, Joseph D.; Prata, Aluizio

    2012-01-01

    The Juno mission to Jupiter requires an antenna with a torus-shaped antenna pattern with approximately 6 dBic gain and circular polarization over the Deep Space Network (DSN) 7-GHz transmit frequency and the 8-GHz receive frequency. Given the large distances that accumulate en-route to Jupiter and the limited power afforded by the solar-powered vehicle, this toroidal low-gain antenna requires as much gain as possible while maintaining a beam width that could facilitate a +/-10deg edge of coverage. The natural antenna that produces a toroidal antenna pattern is the dipole, but the limited approx. = 2.2 dB peak gain would be insufficient. Here a shaped variation of the standard bicone antenna is proposed that could achieve the required gains and bandwidths while maintaining a size that was not excessive. The final geometry that was settled on consisted of a corrugated, shaped bicone, which is fed by a WR112 waveguide-to-coaxial- waveguide transition. This toroidal low-gain antenna (TLGA) geometry produced the requisite gain, moderate sidelobes, and the torus-shaped antenna pattern while maintaining a very good match over the entire required frequency range. Its "horn" geometry is also low-loss and capable of handling higher powers with large margins against multipactor breakdown. The final requirement for the antenna was to link with the DSN with circular polarization. A four-layer meander-line array polarizer was implemented; an approach that was fairly well suited to the TLGA geometry. The principal development of this work was to adapt the standard linear bicone such that its aperture could be increased in order to increase the available gain of the antenna. As one increases the aperture of a standard bicone, the phase variation across the aperture begins to increase, so the larger the aperture becomes, the greater the phase variation. In order to maximize the gain from any aperture antenna, the phase should be kept as uniform as possible. Thus, as the standard

  20. Estimation of teleported and gained parameters in a non-inertial frame

    NASA Astrophysics Data System (ADS)

    Metwally, N.

    2017-04-01

    Quantum Fisher information is introduced as a measure of estimating the teleported information between two users, one of which is uniformly accelerated. We show that the final teleported state depends on the initial parameters, in addition to the gained parameters during the teleportation process. The estimation degree of these parameters depends on the value of the acceleration, the used single mode approximation (within/beyond), the type of encoded information (classic/quantum) in the teleported state, and the entanglement of the initial communication channel. The estimation degree of the parameters can be maximized if the partners teleport classical information.

  1. Spatially uniform and nonuniform analyses of electroencephalographic dynamics,with application to the topography of the alpha rhythm

    NASA Astrophysics Data System (ADS)

    O'Connor, S. C.; Robinson, P. A.

    2004-07-01

    Corticothalamic dynamics are investigated using a model in which spatial nonuniformities are incorporated via the coupling of spatial eigenmodes. Comparison of spectra generated using the nonuniform analysis with those generated using a uniform one demonstrates that, for most frequencies, local activity is only weakly dependent on activity elsewhere in the cortex; however, dispersion of low-wave-number activity ensures that distant dynamics influence local dynamics at low frequencies (below approximately 2Hz ), and at the alpha frequency (approximately 10Hz ), where propagating signals are inherently weakly damped, and wavelengths are large. When certain model parameters have similar spatial profiles, as is expected from physiology, the low-frequency discrepancies tend to cancel, and the uniform analysis with local parameter values is an adequate approximation to the full nonuniform one across the whole spectrum, at least for large-scale nonuniformities. After comparing the uniform and nonuniform analyses, we consider one possible application of the nonuniform analysis: studying the phenomenon of occipital alpha dominance, whereby the alpha frequency and power are greater at the back of the head (occipitally) than at the front. In order to infer realistic nonuniformities in the model parameters, the uniform version of the model is first fitted to data recorded from 98 normal subjects in a waking, eyes-closed state. This yields a set of parameters at each of five electrode sites along the midline. The inferred parameter nonuniformities are consistent with anatomical and physiological constraints. Introducing these spatial profiles into the full nonuniform model then quantitatively reproduces observed site-dependent variations in the alpha power and frequency. The results confirm that the frequency shift is mainly due to a decrease in the corticothalamic propagation delay, but indicate that the delay nonuniformity cannot account for the observed occipital increase in

  2. Stakeholder Perceptions of Cyberbullying Cases: Application of the Uniform Definition of Bullying.

    PubMed

    Moreno, Megan A; Suthamjariya, Nina; Selkie, Ellen

    2018-04-01

    The Uniform Definition of Bullying was developed to address bullying and cyberbullying, and to promote consistency in measurement and policy. The purpose of this study was to understand community stakeholder perceptions of typical cyberbullying cases, and to evaluate how these case descriptions align with the Uniform Definition. In this qualitative case analysis we recruited stakeholders commonly involved in cyberbullying. We used purposeful sampling to identify and recruit adolescents and young adults, parents, and professionals representing education and health care. Participants were asked to write a typical case of cyberbullying and descriptors in the context of a group discussion. We applied content analysis to case excerpts using inductive and deductive approaches, and chi-squared tests for mixed methods analyses. A total of 68 participants contributed; participants included 73% adults and 27% adolescents and young adults. A total of 650 excerpts were coded from participants' example cases and 362 (55.6%) were consistent with components of the Uniform Definition. The most frequently mentioned component of the Uniform Definition was Aggressive Behavior (n = 218 excerpts), whereas Repeated was mentioned infrequently (n = 19). Most participants included two to three components of the Uniform Definition within an example case; none of the example cases included all components of the Uniform Definition. We found that most participants described cyberbullying cases using few components of the Uniform Definition. Findings can be applied toward considering refinement of the Uniform Definition to ensure stakeholders find it applicable to cyberbullying. Copyright © 2017 The Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  3. The Galileo high gain antenna deployment anomaly

    NASA Technical Reports Server (NTRS)

    Johnson, Michael R.

    1994-01-01

    On April 11, 1991, the Galileo spacecraft executed a sequence that would open the spacecraft's High Gain Antenna. The Antenna's launch restraint had been released just after deployment sequence, the antenna, which opens like an umbrella, never reached the fully deployed position. The analyses and tests that followed allowed a conclusive determination of the likely failure mechanisms and pointed to some strategies to use for recovery of the high gain antenna.

  4. Observer-based output feedback control of networked control systems with non-uniform sampling and time-varying delay

    NASA Astrophysics Data System (ADS)

    Meng, Su; Chen, Jie; Sun, Jian

    2017-10-01

    This paper investigates the problem of observer-based output feedback control for networked control systems with non-uniform sampling and time-varying transmission delay. The sampling intervals are assumed to vary within a given interval. The transmission delay belongs to a known interval. A discrete-time model is first established, which contains time-varying delay and norm-bounded uncertainties coming from non-uniform sampling intervals. It is then converted to an interconnection of two subsystems in which the forward channel is delay-free. The scaled small gain theorem is used to derive the stability condition for the closed-loop system. Moreover, the observer-based output feedback controller design method is proposed by utilising a modified cone complementary linearisation algorithm. Finally, numerical examples illustrate the validity and superiority of the proposed method.

  5. MWPC prototyping and performance test for the STAR inner TPC upgrade

    DOE PAGES

    Shen, Fuwang; Wang, Shuai; Kong, Fangang; ...

    2018-04-16

    A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6% and wire pitch precision better than 10 μm. The gas gain uniformity and energy resolution are measured to be better than 1% (RMS) and 20% (FWHM), respectively, using an 55Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. Furthermore, the test resultsmore » show that the constructed iTPC prototype meets all project requirements.« less

  6. MWPC prototyping and performance test for the STAR inner TPC upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Fuwang; Wang, Shuai; Kong, Fangang

    A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6% and wire pitch precision better than 10 μm. The gas gain uniformity and energy resolution are measured to be better than 1% (RMS) and 20% (FWHM), respectively, using an 55Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. Furthermore, the test resultsmore » show that the constructed iTPC prototype meets all project requirements.« less

  7. Modification of saccadic gain by reinforcement

    PubMed Central

    Paeye, Céline; Wallman, Josh

    2011-01-01

    Control of saccadic gain is often viewed as a simple compensatory process in which gain is adjusted over many trials by the postsaccadic retinal error, thereby maintaining saccadic accuracy. Here, we propose that gain might also be changed by a reinforcement process not requiring a visual error. To test this hypothesis, we used experimental paradigms in which retinal error was removed by extinguishing the target at the start of each saccade and either an auditory tone or the vision of the target on the fovea was provided as reinforcement after those saccades that met an amplitude criterion. These reinforcement procedures caused a progressive change in saccade amplitude in nearly all subjects, although the rate of adaptation differed greatly among subjects. When we reversed the contingencies and reinforced those saccades landing closer to the original target location, saccade gain changed back toward normal gain in most subjects. When subjects had saccades adapted first by reinforcement and a week later by conventional intrasaccadic step adaptation, both paradigms yielded similar degrees of gain changes and similar transfer to new amplitudes and to new starting positions of the target step as well as comparable rates of recovery. We interpret these changes in saccadic gain in the absence of postsaccadic retinal error as showing that saccade adaptation is not controlled by a single error signal. More generally, our findings suggest that normal saccade adaptation might involve general learning mechanisms rather than only specialized mechanisms for motor calibration. PMID:21525366

  8. Contrast gain control in first- and second-order motion perception.

    PubMed

    Lu, Z L; Sperling, G

    1996-12-01

    A novel pedestal-plus-test paradigm is used to determine the nonlinear gain-control properties of the first-order (luminance) and the second-order (texture-contrast) motion systems, that is, how these systems' responses to motion stimuli are reduced by pedestals and other masking stimuli. Motion-direction thresholds were measured for test stimuli consisting of drifting luminance and texture-contrast-modulation stimuli superimposed on pedestals of various amplitudes. (A pedestal is a static sine-wave grating of the same type and same spatial frequency as the moving test grating.) It was found that first-order motion-direction thresholds are unaffected by small pedestals, but at pedestal contrasts above 1-2% (5-10 x pedestal threshold), motion thresholds increase proportionally to pedestal amplitude (a Weber law). For first-order stimuli, pedestal masking is specific to the spatial frequency of the test. On the other hand, motion-direction thresholds for texture-contrast stimuli are independent of pedestal amplitude (no gain control whatever) throughout the accessible pedestal amplitude range (from 0 to 40%). However, when baseline carrier contrast increases (with constant pedestal modulation amplitude), motion thresholds increase, showing that gain control in second-order motion is determined not by the modulator (as in first-order motion) but by the carrier. Note that baseline contrast of the carrier is inherently independent of spatial frequency of the modulator. The drastically different gain-control properties of the two motion systems and prior observations of motion masking and motion saturation are all encompassed in a functional theory. The stimulus inputs to both first- and second-order motion process are normalized by feedforward, shunting gain control. The different properties arise because the modulator is used to control the first-order gain and the carrier is used to control the second-order gain.

  9. Comparison of Turbulent Heat-Transfer Results for Uniform Wall Heat Flux and Uniform Wall Temperature

    NASA Technical Reports Server (NTRS)

    Siegel, R.; Sparrow, E. M.

    1960-01-01

    The purpose of this note is to examine in a more precise way how the Nusselt numbers for turbulent heat transfer in both the fully developed and thermal entrance regions of a circular tube are affected by two different wall boundary conditions. The comparisons are made for: (a) Uniform wall temperature (UWT); and (b) uniform wall heat flux (UHF). Several papers which have been concerned with the turbulent thermal entrance region problem are given. 1 Although these analyses have all utilized an eigenvalue formulation for the thermal entrance region there were differences in the choices of eddy diffusivity expressions, velocity distributions, and methods for carrying out the numerical solutions. These differences were also found in the fully developed analyses. Hence when making a comparison of the analytical results for uniform wall temperature and uniform wall heat flux, it was not known if differences in the Nusselt numbers could be wholly attributed to the difference in wall boundary conditions, since all the analytical results were not obtained in a consistent way. To have results which could be directly compared, computations were carried out for the uniform wall temperature case, using the same eddy diffusivity, velocity distribution, and digital computer program employed for uniform wall heat flux. In addition, the previous work was extended to a lower Reynolds number range so that comparisons could be made over a wide range of both Reynolds and Prandtl numbers.

  10. 7 CFR 1006.61 - Computation of uniform prices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., the market administrator shall compute a uniform butterfat price, a uniform skim milk price, and a... section. (b) Uniform skim milk price. The uniform skim milk price per hundredweight, rounded to the... paragraph (a) of this section times 3.5 pounds of butterfat; and (2) Multiply the uniform skim milk price...

  11. 7 CFR 1007.61 - Computation of uniform prices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., the market administrator shall compute a uniform butterfat price, a uniform skim milk price, and a... section. (b) Uniform skim milk price. The uniform skim milk price per hundredweight, rounded to the... paragraph (a) of this section times 3.5 pounds of butterfat; and (2) Multiply the uniform skim milk price...

  12. 7 CFR 1131.61 - Computation of uniform prices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., the market administrator shall compute a uniform butterfat price, a uniform skim milk price, and a... section. (b) Uniform skim milk price. The uniform skim milk price per hundredweight, rounded to the... paragraph (a) of this section times 3.5 pounds of butterfat; and (2) Multiply the uniform skim milk price...

  13. Characterization and Processing of Non-Uniformities in Back-Illuminated CCDs

    NASA Astrophysics Data System (ADS)

    Lemm, Alia D.; Della-Rose, Devin J.; Maddocks, Sally

    2018-01-01

    In astronomical photometry, Charged Coupled Device (CCD) detectors are used to achieve high precision photometry and must be properly calibrated to correct for noise and pixel non-uniformities. Uncalibrated images may contain bias offset, dark current, bias structure and uneven illumination. In addition, standard data reduction is often not sufficient to “normalize” imagery to single-digit millimagnitude (mmag) precision. We are investigating an apparent non-uniformity, or interference pattern, in a back-illuminated sensor, the Alta U-47, attached to a DFM Engineering 41-cm Ritchey-Chrétien f/8 telescope. Based on the amplitude of this effect, we estimate that instrument magnitude peak-to-valley deviations of 50 mmag or more may result. Our initial testing strongly suggests that reflected skylight from high pressure sodium city lights may be the cause of this interference pattern. Our research goals are twofold: to fully characterize this non-uniformity and to determine the best method to remove this interference pattern from our reduced CCD images.

  14. Statistical Searches for Microlensing Events in Large, Non-uniformly Sampled Time-Domain Surveys: A Test Using Palomar Transient Factory Data

    NASA Astrophysics Data System (ADS)

    Price-Whelan, Adrian M.; Agüeros, Marcel A.; Fournier, Amanda P.; Street, Rachel; Ofek, Eran O.; Covey, Kevin R.; Levitan, David; Laher, Russ R.; Sesar, Branimir; Surace, Jason

    2014-01-01

    Many photometric time-domain surveys are driven by specific goals, such as searches for supernovae or transiting exoplanets, which set the cadence with which fields are re-imaged. In the case of the Palomar Transient Factory (PTF), several sub-surveys are conducted in parallel, leading to non-uniform sampling over its ~20,000 deg2 footprint. While the median 7.26 deg2 PTF field has been imaged ~40 times in the R band, ~2300 deg2 have been observed >100 times. We use PTF data to study the trade off between searching for microlensing events in a survey whose footprint is much larger than that of typical microlensing searches, but with far-from-optimal time sampling. To examine the probability that microlensing events can be recovered in these data, we test statistics used on uniformly sampled data to identify variables and transients. We find that the von Neumann ratio performs best for identifying simulated microlensing events in our data. We develop a selection method using this statistic and apply it to data from fields with >10 R-band observations, 1.1 × 109 light curves, uncovering three candidate microlensing events. We lack simultaneous, multi-color photometry to confirm these as microlensing events. However, their number is consistent with predictions for the event rate in the PTF footprint over the survey's three years of operations, as estimated from near-field microlensing models. This work can help constrain all-sky event rate predictions and tests microlensing signal recovery in large data sets, which will be useful to future time-domain surveys, such as that planned with the Large Synoptic Survey Telescope.

  15. 7 CFR 1005.61 - Computation of uniform prices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... month, the market administrator shall compute a uniform butterfat price, a uniform skim milk price, and...) and (a)(2) of this section. (b) Uniform skim milk price. The uniform skim milk price per hundredweight... paragraph (a) of this section times 3.5 pounds of butterfat; and (2) Multiply the uniform skim milk price...

  16. A simple algorithm to improve the performance of the WENO scheme on non-uniform grids

    NASA Astrophysics Data System (ADS)

    Huang, Wen-Feng; Ren, Yu-Xin; Jiang, Xiong

    2018-02-01

    This paper presents a simple approach for improving the performance of the weighted essentially non-oscillatory (WENO) finite volume scheme on non-uniform grids. This technique relies on the reformulation of the fifth-order WENO-JS (WENO scheme presented by Jiang and Shu in J. Comput. Phys. 126:202-228, 1995) scheme designed on uniform grids in terms of one cell-averaged value and its left and/or right interfacial values of the dependent variable. The effect of grid non-uniformity is taken into consideration by a proper interpolation of the interfacial values. On non-uniform grids, the proposed scheme is much more accurate than the original WENO-JS scheme, which was designed for uniform grids. When the grid is uniform, the resulting scheme reduces to the original WENO-JS scheme. In the meantime, the proposed scheme is computationally much more efficient than the fifth-order WENO scheme designed specifically for the non-uniform grids. A number of numerical test cases are simulated to verify the performance of the present scheme.

  17. Quantitative multi-pinhole small-animal SPECT: uniform versus non-uniform Chang attenuation correction.

    PubMed

    Wu, C; de Jong, J R; Gratama van Andel, H A; van der Have, F; Vastenhouw, B; Laverman, P; Boerman, O C; Dierckx, R A J O; Beekman, F J

    2011-09-21

    Attenuation of photon flux on trajectories between the source and pinhole apertures affects the quantitative accuracy of reconstructed single-photon emission computed tomography (SPECT) images. We propose a Chang-based non-uniform attenuation correction (NUA-CT) for small-animal SPECT/CT with focusing pinhole collimation, and compare the quantitative accuracy with uniform Chang correction based on (i) body outlines extracted from x-ray CT (UA-CT) and (ii) on hand drawn body contours on the images obtained with three integrated optical cameras (UA-BC). Measurements in phantoms and rats containing known activities of isotopes were conducted for evaluation. In (125)I, (201)Tl, (99m)Tc and (111)In phantom experiments, average relative errors comparing to the gold standards measured in a dose calibrator were reduced to 5.5%, 6.8%, 4.9% and 2.8%, respectively, with NUA-CT. In animal studies, these errors were 2.1%, 3.3%, 2.0% and 2.0%, respectively. Differences in accuracy on average between results of NUA-CT, UA-CT and UA-BC were less than 2.3% in phantom studies and 3.1% in animal studies except for (125)I (3.6% and 5.1%, respectively). All methods tested provide reasonable attenuation correction and result in high quantitative accuracy. NUA-CT shows superior accuracy except for (125)I, where other factors may have more impact on the quantitative accuracy than the selected attenuation correction.

  18. Logical optimization for database uniformization

    NASA Technical Reports Server (NTRS)

    Grant, J.

    1984-01-01

    Data base uniformization refers to the building of a common user interface facility to support uniform access to any or all of a collection of distributed heterogeneous data bases. Such a system should enable a user, situated anywhere along a set of distributed data bases, to access all of the information in the data bases without having to learn the various data manipulation languages. Furthermore, such a system should leave intact the component data bases, and in particular, their already existing software. A survey of various aspects of the data bases uniformization problem and a proposed solution are presented.

  19. Transient well flow in layered aquifer systems: the uniform well-face drawdown solution

    NASA Astrophysics Data System (ADS)

    Hemker, C. J.

    1999-11-01

    Previously a hybrid analytical-numerical solution for the general problem of computing transient well flow in vertically heterogeneous aquifers was proposed by the author. The radial component of flow was treated analytically, while the finite-difference technique was used for the vertical flow component only. In the present work the hybrid solution has been modified by replacing the previously assumed uniform well-face gradient (UWG) boundary condition in such a way that the drawdown remains uniform along the well screen. The resulting uniform well-face drawdown (UWD) solution also includes the effects of a finite diameter well, wellbore storage and a thin skin, while partial penetration and vertical heterogeneity are accommodated by the one-dimensional discretization. Solutions are proposed for well flow caused by constant, variable and slug discharges. The model was verified by comparing wellbore drawdowns and well-face flux distributions with published numerical solutions. Differences between UWG and UWD well flow will occur in all situations with vertical flow components near the well, which is demonstrated by considering: (1) partially penetrating wells in confined aquifers, (2) fully penetrating wells in unconfined aquifers with delayed response and (3) layered aquifers and leaky multiaquifer systems. The presented solution can be a powerful tool for solving many well-hydraulic problems, including well tests, flowmeter tests, slug tests and pumping tests. A computer program for the analysis of pumping tests, based on the hybrid analytical-numerical technique and UWG or UWD conditions, is available from the author.

  20. Bending strength of shallow glued-laminated beams of a uniform grade

    Treesearch

    Catherine M. Marx; Russell C. Moody

    1981-01-01

    Ninety glued-laminated Douglas-fir or southern pine beams of a uniform grade with 2-, 4-, or 6-laminations were evaluated in static bending tests. No specially graded tension laminations or end joints were used. The purpose of the tests was to determine which of three present design criteria best predict near minimum bending strength values for shallow glued-laminated...

  1. Evaluation of illumination system uniformity for wide-field biomedical hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Sawyer, Travis W.; Siri Luthman, A.; E Bohndiek, Sarah

    2017-04-01

    Hyperspectral imaging (HSI) systems collect both spatial (morphological) and spectral (chemical) information from a sample. HSI can provide sensitive analysis for biological and medical applications, for example, simultaneously measuring reflectance and fluorescence properties of a tissue, which together with structural information could improve early cancer detection and tumour characterisation. Illumination uniformity is a critical pre-condition for quantitative data extraction from an HSI system. Non-uniformity can cause glare, specular reflection and unwanted shading, which negatively impact statistical analysis procedures used to extract abundance of different chemical species. Here, we model and evaluate several illumination systems frequently used in wide-field biomedical imaging to test their potential for HSI. We use the software LightTools and FRED. The analysed systems include: a fibre ring light; a light emitting diode (LED) ring; and a diffuse scattering dome. Each system is characterised for spectral, spatial, and angular uniformity, as well as transfer efficiency. Furthermore, an approach to measure uniformity using the Kullback-Leibler divergence (KLD) is introduced. The KLD is generalisable to arbitrary illumination shapes, making it an attractive approach for characterising illumination distributions. Although the systems are quite comparable in their spatial and spectral uniformity, the most uniform angular distribution is achieved using a diffuse scattering dome, yielding a contrast of 0.503 and average deviation of 0.303 over a ±60° field of view with a 3.9% model error in the angular domain. Our results suggest that conventional illumination sources can be applied in HSI, but in the case of low light levels, bespoke illumination sources may offer improved performance.

  2. Signal uniformity of mammography systems and its impact on test results from contrast detail phantoms

    NASA Astrophysics Data System (ADS)

    Kaar, M.; Semturs, F.; Hummel, J.; Hoffmann, R.; Figl, M.

    2015-03-01

    Technical quality assurance (TQA) procedures for mammography systems usually include tests with a contrast-detail phantom. These phantoms contain multiple objects of varying dimensions arranged on a flat body. Exposures of the phantom are then evaluated by an observer, either human or software. One well-known issue of this method is that dose distribution is not uniform across the image area of any mammography system, mainly due to the heel effect. The purpose of this work is to investigate to what extent image quality differs across the detector plane. We analyze a total of 320 homogeneous mammography exposures from 32 radiology institutes. Systems of different models and manufacturers, both computed radiography (CR) and direct radiography (DR) are included. All images were taken from field installations operated within the nationwide Austrian mammography screening program, which includes mandatory continuous TQA. We calculate signal-to-noise ratios (SNR) for 15 regions of interest arranged to cover the area of the phantom. We define the 'signal range' of an image and compare this value categorized by technologies. We found the deviations of SNR greater in anterior-posterior than in lateral direction. SNR ranges are significantly higher for CR systems than for DR systems.

  3. Uniform Corrosion and General Dissolution of Aluminum Alloys 2024-T3, 6061-T6, and 7075-T6

    NASA Astrophysics Data System (ADS)

    Huang, I.-Wen

    Uniform corrosion and general dissolution of aluminum alloys was not as well-studied in the past, although it was known for causing significant amount of weight loss. This work comprises four chapters to understand uniform corrosion of aluminum alloys 2024-T3, 6061-T6, and 7075-T6. A preliminary weight loss experiment was performed for distinguishing corrosion induced weight loss attributed to uniform corrosion and pitting corrosion. The result suggested that uniform corrosion generated a greater mass loss than pitting corrosion. First, to understand uniform corrosion mechanism and kinetics in different environments, a series of static immersion tests in NaCl solutions were performed to provide quantitative measurement of uniform corrosion. Thereafter, uniform corrosion development as a function of temperature, pH, Cl-, and time was investigated to understand the influence of environmental factors. Faster uniform corrosion rate has been found at lower temperature (20 and 40°C) than at higher temperature (60 and 80°C) due to accelerated corrosion product formation at high temperatures inhibiting corrosion reactions. Electrochemical tests including along with scanning electron microscopy (SEM) were utilized to study the temperature effect. Second, in order to further understand the uniform corrosion influence on pit growth kinetics, a long term exposures for 180 days in both immersion and ASTM-B117 test were performed. Uniform corrosion induced surface recession was found to have limited impact on pit geometry regardless of exposure methods. It was also found that the competition for limited cathodic current from uniform corrosion the primary rate limiting factor for pit growth. Very large pits were found after uniform corrosion growth reached a plateau due to corrosion product coverage. Also, optical microscopy and focused ion beam (FIB) imaging has provided more insights of distinctive pitting geometry and subsurface damages found from immersion samples and B117

  4. Testing CREATE at Community Colleges: An Examination of Faculty Perspectives and Diverse Student Gains.

    PubMed

    Kenyon, Kristy L; Onorato, Morgan E; Gottesman, Alan J; Hoque, Jamila; Hoskins, Sally G

    2016-01-01

    CREATE (Consider, Read, Elucidate the hypotheses, Analyze and interpret the data, and Think of the next Experiment) is an innovative pedagogy for teaching science through the intensive analysis of scientific literature. Initiated at the City College of New York, a minority-serving institution, and regionally expanded in the New York/New Jersey/Pennsylvania area, this methodology has had multiple positive impacts on faculty and students in science, technology, engineering, and mathematics courses. To determine whether the CREATE strategy is effective at the community college (2-yr) level, we prepared 2-yr faculty to use CREATE methodologies and investigated CREATE implementation at community colleges in seven regions of the United States. We used outside evaluation combined with pre/postcourse assessments of students to test related hypotheses: 1) workshop-trained 2-yr faculty teach effectively with the CREATE strategy in their first attempt, and 2) 2-yr students in CREATE courses make cognitive and affective gains during their CREATE quarter or semester. Community college students demonstrated positive shifts in experimental design and critical-thinking ability concurrent with gains in attitudes/self-rated learning and maturation of epistemological beliefs about science. © 2016 K. L. Kenyon et al. CBE—Life Sciences Education © 2016 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  5. 24 CFR 5.801 - Uniform financial reporting standards.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Uniform financial reporting... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Uniform Financial Reporting Standards § 5.801 Uniform financial reporting standards. (a) Applicability. This subpart H implements uniform...

  6. 24 CFR 5.801 - Uniform financial reporting standards.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Uniform financial reporting... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Uniform Financial Reporting Standards § 5.801 Uniform financial reporting standards. (a) Applicability. This subpart H implements uniform...

  7. 7 CFR 51.2085 - Fairly uniform color.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Fairly uniform color. 51.2085 Section 51.2085... Definitions § 51.2085 Fairly uniform color. Fairly uniform color means that the shells do not show excessive variation in color, whether bleached or natural. ...

  8. 7 CFR 51.2085 - Fairly uniform color.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Fairly uniform color. 51.2085 Section 51.2085... Definitions § 51.2085 Fairly uniform color. Fairly uniform color means that the shells do not show excessive variation in color, whether bleached or natural. ...

  9. Neuro-adaptive backstepping control of SISO non-affine systems with unknown gain sign.

    PubMed

    Ramezani, Zahra; Arefi, Mohammad Mehdi; Zargarzadeh, Hassan; Jahed-Motlagh, Mohammad Reza

    2016-11-01

    This paper presents two neuro-adaptive controllers for a class of uncertain single-input, single-output (SISO) nonlinear non-affine systems with unknown gain sign. The first approach is state feedback controller, so that a neuro-adaptive state-feedback controller is constructed based on the backstepping technique. The second approach is an observer-based controller and K-filters are designed to estimate the system states. The proposed method relaxes a priori knowledge of control gain sign and therefore by utilizing the Nussbaum-type functions this problem is addressed. In these methods, neural networks are employed to approximate the unknown nonlinear functions. The proposed adaptive control schemes guarantee that all the closed-loop signals are semi-globally uniformly ultimately bounded (SGUUB). Finally, the theoretical results are numerically verified through simulation examples. Simulation results show the effectiveness of the proposed methods. Copyright © 2016 ISA. All rights reserved.

  10. Uniform-related infection control practices of dental students

    PubMed Central

    Aljohani, Yazan; Almutadares, Mohammed; Alfaifi, Khalid; El Madhoun, Mona; Albahiti, Maysoon H; Al-Hazmi, Nadia

    2017-01-01

    Background Uniform-related infection control practices are sometimes overlooked and underemphasized. In Saudi Arabia, personal protective equipment must meet global standards for infection control, but the country’s Islamic legislature also needs to be taken into account. Aim To assess uniform-related infection control practices of a group of dental students in a dental school in Saudi Arabia and compare the results with existing literature related to cross-contamination through uniforms in the dental field. Method A questionnaire was formulated and distributed to dental students at King Abdulaziz University Faculty of Dentistry in Jeddah, Saudi Arabia, which queried the students about their uniform-related infection control practices and their methods and frequency of laundering and sanitizing their uniforms, footwear, and name tags. Results There is a significant difference between genders with regard to daily uniform habits. The frequency of uniform washing was below the standard and almost 30% of students were not aware of how their uniforms are washed. Added to this, there is no consensus on a unified uniform for male and female students. Conclusion Information on preventing cross-contamination through wearing uniforms must be supplied, reinforced, and emphasized while taking into consideration the cultural needs of the Saudi society. PMID:28490894

  11. An integral formulation for wave propagation on weakly non-uniform potential flows

    NASA Astrophysics Data System (ADS)

    Mancini, Simone; Astley, R. Jeremy; Sinayoko, Samuel; Gabard, Gwénaël; Tournour, Michel

    2016-12-01

    An integral formulation for acoustic radiation in moving flows is presented. It is based on a potential formulation for acoustic radiation on weakly non-uniform subsonic mean flows. This work is motivated by the absence of suitable kernels for wave propagation on non-uniform flow. The integral solution is formulated using a Green's function obtained by combining the Taylor and Lorentz transformations. Although most conventional approaches based on either transform solve the Helmholtz problem in a transformed domain, the current Green's function and associated integral equation are derived in the physical space. A dimensional error analysis is developed to identify the limitations of the current formulation. Numerical applications are performed to assess the accuracy of the integral solution. It is tested as a means of extrapolating a numerical solution available on the outer boundary of a domain to the far field, and as a means of solving scattering problems by rigid surfaces in non-uniform flows. The results show that the error associated with the physical model deteriorates with increasing frequency and mean flow Mach number. However, the error is generated only in the domain where mean flow non-uniformities are significant and is constant in regions where the flow is uniform.

  12. School Uniforms: Esprit de Corps.

    ERIC Educational Resources Information Center

    Ryan, Rosemary P.; Ryan, Thomas E.

    1998-01-01

    The benefits of school uniforms far outweigh their short-term costs. School uniforms not only keep students safe, but they increase their self-esteem, promote a more positive attitude toward school, lead to improved student behavior, and help blur social-class distinctions. Students are allowed to wear their own political or religious messages,…

  13. Pellicle transmission uniformity requirements

    NASA Astrophysics Data System (ADS)

    Brown, Thomas L.; Ito, Kunihiro

    1998-12-01

    Controlling critical dimensions of devices is a constant battle for the photolithography engineer. Current DUV lithographic process exposure latitude is typically 12 to 15% of the total dose. A third of this exposure latitude budget may be used up by a variable related to masking that has not previously received much attention. The emphasis on pellicle transmission has been focused on increasing the average transmission. Much less, attention has been paid to transmission uniformity. This paper explores the total demand on the photospeed latitude budget, the causes of pellicle transmission nonuniformity and examines reasonable expectations for pellicle performance. Modeling is used to examine how the two primary errors in pellicle manufacturing contribute to nonuniformity in transmission. World-class pellicle transmission uniformity standards are discussed and a comparison made between specifications of other components in the photolithographic process. Specifications for other materials or parameters are used as benchmarks to develop a proposed industry standard for pellicle transmission uniformity.

  14. 7 CFR 1425.13 - Uniform marketing agreement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Uniform marketing agreement. 1425.13 Section 1425.13... OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS COOPERATIVE MARKETING ASSOCIATIONS § 1425.13 Uniform marketing agreement. (a) A CMA must enter into a uniform marketing agreement with each member who...

  15. 7 CFR 1425.13 - Uniform marketing agreement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 10 2013-01-01 2013-01-01 false Uniform marketing agreement. 1425.13 Section 1425.13... OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS COOPERATIVE MARKETING ASSOCIATIONS § 1425.13 Uniform marketing agreement. (a) A CMA must enter into a uniform marketing agreement with each member who...

  16. 7 CFR 1425.13 - Uniform marketing agreement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 10 2012-01-01 2012-01-01 false Uniform marketing agreement. 1425.13 Section 1425.13... OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS COOPERATIVE MARKETING ASSOCIATIONS § 1425.13 Uniform marketing agreement. (a) A CMA must enter into a uniform marketing agreement with each member who...

  17. 32 CFR 199.18 - Uniform HMO Benefit.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 2 2014-07-01 2014-07-01 false Uniform HMO Benefit. 199.18 Section 199.18... Benefit. (a) In general. There is established a Uniform HMO Benefit. The purpose of the Uniform HMO benefit is to establish a health benefit option modeled on health maintenance organization plans. This...

  18. 78 FR 48366 - Civilian Health and Medical Program of the Uniformed Services (CHAMPUS); TRICARE Uniform Health...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-08

    ... Organization (HMO) Benefit--Prime Enrollment Fee Exemption for Survivors of Active Duty Deceased Sponsors and... Survivors of Active Duty Deceased Sponsors and Medically Retired Uniformed Services Members and their... uniform within the following groups: dependents of active duty members in [[Page 48367

  19. Combined Loads Test Fixture for Thermal-Structural Testing Aerospace Vehicle Panel Concepts

    NASA Technical Reports Server (NTRS)

    Fields, Roger A.; Richards, W. Lance; DeAngelis, Michael V.

    2004-01-01

    A structural test requirement of the National Aero-Space Plane (NASP) program has resulted in the design, fabrication, and implementation of a combined loads test fixture. Principal requirements for the fixture are testing a 4- by 4-ft hat-stiffened panel with combined axial (either tension or compression) and shear load at temperatures ranging from room temperature to 915 F, keeping the test panel stresses caused by the mechanical loads uniform, and thermal stresses caused by non-uniform panel temperatures minimized. The panel represents the side fuselage skin of an experimental aerospace vehicle, and was produced for the NASP program. A comprehensive mechanical loads test program using the new test fixture has been conducted on this panel from room temperature to 500 F. Measured data have been compared with finite-element analyses predictions, verifying that uniform load distributions were achieved by the fixture. The overall correlation of test data with analysis is excellent. The panel stress distributions and temperature distributions are very uniform and fulfill program requirements. This report provides details of an analytical and experimental validation of the combined loads test fixture. Because of its simple design, this unique test fixture can accommodate panels from a variety of aerospace vehicle designs.

  20. 46 CFR 310.63 - Uniforms and textbooks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Uniforms and textbooks. 310.63 Section 310.63 Shipping MARITIME ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRAINING MERCHANT MARINE TRAINING Admission and Training of Midshipmen at the United States Merchant Marine Academy § 310.63 Uniforms and textbooks. The Academy shall supply midshipmen uniforms an...

  1. Drug testing and flow cytometry analysis on a large number of uniform sized tumor spheroids using a microfluidic device

    NASA Astrophysics Data System (ADS)

    Patra, Bishnubrata; Peng, Chien-Chung; Liao, Wei-Hao; Lee, Chau-Hwang; Tung, Yi-Chung

    2016-02-01

    Three-dimensional (3D) tumor spheroid possesses great potential as an in vitro model to improve predictive capacity for pre-clinical drug testing. In this paper, we combine advantages of flow cytometry and microfluidics to perform drug testing and analysis on a large number (5000) of uniform sized tumor spheroids. The spheroids are formed, cultured, and treated with drugs inside a microfluidic device. The spheroids can then be harvested from the device without tedious operation. Due to the ample cell numbers, the spheroids can be dissociated into single cells for flow cytometry analysis. Flow cytometry provides statistical information in single cell resolution that makes it feasible to better investigate drug functions on the cells in more in vivo-like 3D formation. In the experiments, human hepatocellular carcinoma cells (HepG2) are exploited to form tumor spheroids within the microfluidic device, and three anti-cancer drugs: Cisplatin, Resveratrol, and Tirapazamine (TPZ), and their combinations are tested on the tumor spheroids with two different sizes. The experimental results suggest the cell culture format (2D monolayer vs. 3D spheroid) and spheroid size play critical roles in drug responses, and also demonstrate the advantages of bridging the two techniques in pharmaceutical drug screening applications.

  2. Sarcomere mechanics in uniform and non-uniform cardiac muscle: a link between pump function and arrhythmias.

    PubMed

    ter Keurs, Henk E D J; Shinozaki, Tsuyoshi; Zhang, Ying Ming; Zhang, Mei Luo; Wakayama, Yuji; Sugai, Yoshinao; Kagaya, Yutaka; Miura, Masahito; Boyden, Penelope A; Stuyvers, Bruno D M; Landesberg, Amir

    2008-01-01

    Starling's Law and the well-known end-systolic pressure-volume relationship (ESPVR) of the left ventricle reflect the effect of sarcomere length (SL) on stress (sigma) development and shortening by myocytes in the uniform ventricle. We show here that tetanic contractions of rat cardiac trabeculae exhibit a sigma-SL relationship at saturating [Ca2+] that depends on sarcomere geometry in a manner similar to skeletal sarcomeres and the existence of opposing forces in cardiac muscle shortened below slack length. The sigma-SL-[Ca2+]free relationships (sigma-SL-CaR) at submaximal [Ca2+] in intact and skinned trabeculae were similar, albeit that the sensitivity for Ca2+ of intact muscle was higher. We analyzed the mechanisms underlying the sigma-SL-CaR using a kinetic model where we assumed that the rates of Ca2+ binding by Troponin-C (Tn-C) and/or cross-bridge (XB) cycling are determined by SL, [Ca2+] or stress. We analyzed the correlation between the model results and steady state stress measurements at varied SL and [Ca2+] from skinned rat cardiac trabeculae to test the hypotheses that: (i) the dominant feedback mechanism is SL, stress or [Ca2+]-dependent; and (ii) the feedback mechanism regulates: Tn-C-Ca2+ affinity, XB kinetics or, unitary XB-force. The analysis strongly suggests that feedback of the number of strong XBs to cardiac Tn-C-Ca2+ affinity is the dominant mechanism that regulates XB recruitment. Application of this concept in a mathematical model of twitch-stress accurately reproduced the sigma-SL-CaR and the time course of twitch-stress as well as the time course of intracellular [Ca2+]i. Modeling of the response of the cardiac twitch to rapid stress changes using the above feedback model uniquely predicted the occurrence of [Ca2+]i transients as a result of accelerated Ca2+ dissociation from Tn-C. The above concept has important repercussions for the non-uniformly contracting heart in which arrhythmogenic Ca2+ waves arise from weakened areas in cardiac

  3. 78 FR 34292 - Civilian Health and Medical Program of the Uniformed Services (CHAMPUS); TRICARE Uniform Health...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-07

    ... Organization (HMO) Benefit--Prime Enrollment Fee Exemption for Survivors of Active Duty Deceased Sponsors and... Survivors of Active Duty Deceased Sponsors and Medically Retired Uniformed Services Members and their... uniform within the following groups: dependents of active duty members in pay grades of E-4 and below...

  4. 7 CFR 52.1007 - Uniformity of size.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Uniformity of size. 52.1007 Section 52.1007... PROCESSED FOOD PRODUCTS 1 United States Standards for Grades of Dates Factors of Quality § 52.1007... uniform in size may be given a score of 9 or 10 points. “Practically uniform in size” means that not more...

  5. GAIN Technology Workshops Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braase, Lori Ann

    National and global demand for nuclear energy is increasing and United States (U.S.) global leadership is eroding. There is a sense of urgency with respect to the deployment of the innovative nuclear energy technologies. The Gateway for Accelerated Innovation in Nuclear (GAIN) initiative is based on the simultaneous achievement of three strategic goals. The first is maintaining global technology leadership within the U.S. Department of Energy (DOE). The second is enabling global industrial leadership for nuclear vendors and suppliers. The third is focused on utility optimization of nuclear energy within the clean energy portfolio. An effective public-private partnership is requiredmore » to achieve these goals. DOEs recognizes the recent sense of urgency new developers and investors have in getting their concepts to market. They know that time to market for nuclear technology takes too long and the facilities needed to conduct the necessary research, development and demonstration (RD&D) activities are very expensive to develop and maintain. Early technologies, in the lower technology readiness levels (TRL) need materials testing, analysis, modeling, code development, etc., most of which currently exists in the DOE national laboratory system. However, mature technologies typically need large component testing and demonstration facilities, which are expensive and long-lead efforts. By understanding the needs of advanced nuclear technology developers, GAIN will connect DOE national laboratory capabilities (e.g., facilities, expertise, materials, and data) with industry RD&D needs. In addition, GAIN is working with the Nuclear Regulatory Commission (NRC) to streamline processes and increase understanding of the licensing requirements for advanced reactors.« less

  6. Continuity of pullback and uniform attractors

    NASA Astrophysics Data System (ADS)

    Hoang, Luan T.; Olson, Eric J.; Robinson, James C.

    2018-03-01

    We study the continuity of pullback and uniform attractors for non-autonomous dynamical systems with respect to perturbations of a parameter. Consider a family of dynamical systems parameterized by λ ∈ Λ, where Λ is a complete metric space, such that for each λ ∈ Λ there exists a unique pullback attractor Aλ (t). Using the theory of Baire category we show under natural conditions that there exists a residual set Λ* ⊆ Λ such that for every t ∈ R the function λ ↦Aλ (t) is continuous at each λ ∈Λ* with respect to the Hausdorff metric. Similarly, given a family of uniform attractors Aλ, there is a residual set at which the map λ ↦Aλ is continuous. We also introduce notions of equi-attraction suitable for pullback and uniform attractors and then show when Λ is compact that the continuity of pullback attractors and uniform attractors with respect to λ is equivalent to pullback equi-attraction and, respectively, uniform equi-attraction. These abstract results are then illustrated in the context of the Lorenz equations and the two-dimensional Navier-Stokes equations.

  7. 34 CFR 462.43 - How is educational gain measured?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...(b), with the student's educational functioning level as measured by the post-test described in § 462... reading score on the pre-test with the reading score on the post-test. (2) A student is considered to have made an educational gain when the student's post-test indicates that the student has completed one or...

  8. 34 CFR 462.43 - How is educational gain measured?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...(b), with the student's educational functioning level as measured by the post-test described in § 462... reading score on the pre-test with the reading score on the post-test. (2) A student is considered to have made an educational gain when the student's post-test indicates that the student has completed one or...

  9. 34 CFR 462.43 - How is educational gain measured?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...(b), with the student's educational functioning level as measured by the post-test described in § 462... reading score on the pre-test with the reading score on the post-test. (2) A student is considered to have made an educational gain when the student's post-test indicates that the student has completed one or...

  10. 34 CFR 462.43 - How is educational gain measured?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...(b), with the student's educational functioning level as measured by the post-test described in § 462... reading score on the pre-test with the reading score on the post-test. (2) A student is considered to have made an educational gain when the student's post-test indicates that the student has completed one or...

  11. 34 CFR 462.43 - How is educational gain measured?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...(b), with the student's educational functioning level as measured by the post-test described in § 462... reading score on the pre-test with the reading score on the post-test. (2) A student is considered to have made an educational gain when the student's post-test indicates that the student has completed one or...

  12. Effect of surfactants on weight gain in mice.

    PubMed

    Kaneene, J B; Ross, R W

    1986-03-01

    A study was conducted to determine if four surfactants can induce increased weight gain in the mouse. Basic-H, Triton X-100, Amway All Purpose Adjuvant and X-77 were put in water and fed to various groups of ICR 21 day old female mice for a period of 43 days. All the mice were clinically normal throughout the study period. Pathological examination of a random sample of the mice revealed no gross pathological changes. Similarly, histopathological examination of the lungs, livers and intestines did not reveal any visible lesions. Basic-H and Amway surfactants induced weight gain, though not significantly, better at 0.1% (V/V) concentration while X-77 and Triton X-100 induced weight gain better at 0.4% (V/V) concentration. Overall results show that none of the surfactants tested induced significant weight gain.

  13. Integrating uniform design and response surface methodology to optimize thiacloprid suspension

    PubMed Central

    Li, Bei-xing; Wang, Wei-chang; Zhang, Xian-peng; Zhang, Da-xia; Mu, Wei; Liu, Feng

    2017-01-01

    A model 25% suspension concentrate (SC) of thiacloprid was adopted to evaluate an integrative approach of uniform design and response surface methodology. Tersperse2700, PE1601, xanthan gum and veegum were the four experimental factors, and the aqueous separation ratio and viscosity were the two dependent variables. Linear and quadratic polynomial models of stepwise regression and partial least squares were adopted to test the fit of the experimental data. Verification tests revealed satisfactory agreement between the experimental and predicted data. The measured values for the aqueous separation ratio and viscosity were 3.45% and 278.8 mPa·s, respectively, and the relative errors of the predicted values were 9.57% and 2.65%, respectively (prepared under the proposed conditions). Comprehensive benefits could also be obtained by appropriately adjusting the amount of certain adjuvants based on practical requirements. Integrating uniform design and response surface methodology is an effective strategy for optimizing SC formulas. PMID:28383036

  14. Impact of School Uniforms on Student Discipline and the Learning Climate: A Comparative Case Study of Two Middle Schools with Uniform Dress Codes and Two Middle Schools without Uniform Dress Codes

    ERIC Educational Resources Information Center

    Dulin, Charles Dewitt

    2016-01-01

    The purpose of this research is to evaluate the impact of uniform dress codes on a school's climate for student behavior and learning in four middle schools in North Carolina. The research will compare the perceptions of parents, teachers, and administrators in schools with uniform dress codes against schools without uniform dress codes. This…

  15. Tablet splitting and weight uniformity of half-tablets of 4 medications in pharmacy practice.

    PubMed

    Tahaineh, Linda M; Gharaibeh, Shadi F

    2012-08-01

    Tablet splitting is a common practice for multiple reasons including cost savings; however, it does not necessarily result in weight-uniform half-tablets. To determine weight uniformity of half-tablets resulting from splitting 4 products available in the Jordanian market and investigate the effect of tablet characteristics on weight uniformity of half-tablets. Ten random tablets each of warfarin 5 mg, digoxin 0.25 mg, phenobarbital 30 mg, and prednisolone 5 mg were weighed and split by 6 PharmD students using a knife. The resulting half-tablets were weighed and evaluated for weight uniformity. Other relevant physical characteristics of the 4 products were measured. The average tablet hardness of the sampled tablets ranged from 40.3 N to 68.9 N. Digoxin, phenobarbital, and prednisolone half-tablets failed the weight uniformity test; however, warfarin half-tablets passed. Digoxin, warfarin, and phenobarbital tablets had a score line and warfarin tablets had the deepest score line of 0.81 mm. Splitting warfarin tablets produces weight-uniform half-tablets that may possibly be attributed to the hardness and the presence of a deep score line. Digoxin, phenobarbital, and prednisolone tablet splitting produces highly weight variable half-tablets. This can be of clinical significance in the case of the narrow therapeutic index medication digoxin.

  16. Uniform-droplet spray forming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blue, C.A.; Sikka, V.K.; Chun, Jung-Hoon

    1997-04-01

    The uniform-droplet process is a new method of liquid-metal atomization that results in single droplets that can be used to produce mono-size powders or sprayed-on to substrates to produce near-net shapes with tailored microstructure. The mono-sized powder-production capability of the uniform-droplet process also has the potential of permitting engineered powder blends to produce components of controlled porosity. Metal and alloy powders are commercially produced by at least three different methods: gas atomization, water atomization, and rotating disk. All three methods produce powders of a broad range in size with a very small yield of fine powders with single-sized droplets thatmore » can be used to produce mono-size powders or sprayed-on substrates to produce near-net shapes with tailored microstructures. The economical analysis has shown the process to have the potential of reducing capital cost by 50% and operating cost by 37.5% when applied to powder making. For the spray-forming process, a 25% savings is expected in both the capital and operating costs. The project is jointly carried out at Massachusetts Institute of Technology (MIT), Tuffs University, and Oak Ridge National Laboratory (ORNL). Preliminary interactions with both finished parts and powder producers have shown a strong interest in the uniform-droplet process. Systematic studies are being conducted to optimize the process parameters, understand the solidification of droplets and spray deposits, and develop a uniform-droplet-system (UDS) apparatus appropriate for processing engineering alloys.« less

  17. Use of Bayesian Methods to Analyze and Visualize Content Uniformity Capability Versus United States Pharmacopeia and ASTM Standards.

    PubMed

    Hofer, Jeffrey D; Rauk, Adam P

    2017-02-01

    The purpose of this work was to develop a straightforward and robust approach to analyze and summarize the ability of content uniformity data to meet different criteria. A robust Bayesian statistical analysis methodology is presented which provides a concise and easily interpretable visual summary of the content uniformity analysis results. The visualization displays individual batch analysis results and shows whether there is high confidence that different content uniformity criteria could be met a high percentage of the time in the future. The 3 tests assessed are as follows: (a) United States Pharmacopeia Uniformity of Dosage Units <905>, (b) a specific ASTM E2810 Sampling Plan 1 criterion to potentially be used for routine release testing, and (c) another specific ASTM E2810 Sampling Plan 2 criterion to potentially be used for process validation. The approach shown here could readily be used to create similar result summaries for other potential criteria. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  18. Arctic storms simulated in atmospheric general circulation models under uniform high, uniform low, and variable resolutions

    NASA Astrophysics Data System (ADS)

    Roesler, E. L.; Bosler, P. A.; Taylor, M.

    2016-12-01

    The impact of strong extratropical storms on coastal communities is large, and the extent to which storms will change with a warming Arctic is unknown. Understanding storms in reanalysis and in climate models is important for future predictions. We know that the number of detected Arctic storms in reanalysis is sensitive to grid resolution. To understand Arctic storm sensitivity to resolution in climate models, we describe simulations designed to identify and compare Arctic storms at uniform low resolution (1 degree), at uniform high resolution (1/8 degree), and at variable resolution (1 degree to 1/8 degree). High-resolution simulations resolve more fine-scale structure and extremes, such as storms, in the atmosphere than a uniform low-resolution simulation. However, the computational cost of running a globally uniform high-resolution simulation is often prohibitive. The variable resolution tool in atmospheric general circulation models permits regional high-resolution solutions at a fraction of the computational cost. The storms are identified using the open-source search algorithm, Stride Search. The uniform high-resolution simulation has over 50% more storms than the uniform low-resolution and over 25% more storms than the variable resolution simulations. Storm statistics from each of the simulations is presented and compared with reanalysis. We propose variable resolution as a cost-effective means of investigating physics/dynamics coupling in the Arctic environment. Future work will include comparisons with observed storms to investigate tuning parameters for high resolution models. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. SAND2016-7402 A

  19. Methods of obtaining a uniform volume concentration of implanted ions

    NASA Astrophysics Data System (ADS)

    Reutov, V. F.

    1998-05-01

    Three simple practical methods of irradiation with high energy particles (>5 MeV/n), providing the conditions of obtaining a uniform volume concentration of the implanted ions in the massive samples are described in the present paper. Realization of the condition of two-sided irradiation of a plane sample during its rotation in the flux of the projectiles is the basis of the first method. The use of free air as a filter with varying absorbent ability due to the movement of the irradiated sample along ion beam brought to the atmosphere is at the basis of the second method of uniform ion alloying. The third method of obtaining a uniform volume concentration of the implanted ions in a massive sample consists of sample irradiation through the absorbent filter in the shape of a foil curved according to the parabolic law moving along its surface. The first method is the most effective for obtaining a great number of the samples, for mechanical tests, for example, the second one - for irradiation in different gaseous media, the third one - for obtaining high concentration of the implanted ions under controlled (regulated) thermal and deformation conditions.

  20. Uniform insulation applied-B ion diode

    DOEpatents

    Seidel, David B.; Slutz, Stephen A.

    1988-01-01

    An applied-B field extraction ion diode has uniform insulation over an anode surface for increased efficiency. When the uniform insulation is accomplished with anode coils, and a charge-exchange foil is properly placed, the ions may be focused at a point on the z axis.

  1. A School Uniform Program That Works.

    ERIC Educational Resources Information Center

    Loesch, Paul C.

    1995-01-01

    According to advocates, school uniforms reduce gang influence, decrease families' clothing expenditures, and help mitigate potentially divisive cultural and economic differences. Aiming to improve school climate, a California elementary school adopted uniforms as a source of pride and affiliation. This article describes the development of the…

  2. Study on Mosaic and Uniform Color Method of Satellite Image Fusion in Large Srea

    NASA Astrophysics Data System (ADS)

    Liu, S.; Li, H.; Wang, X.; Guo, L.; Wang, R.

    2018-04-01

    Due to the improvement of satellite radiometric resolution and the color difference for multi-temporal satellite remote sensing images and the large amount of satellite image data, how to complete the mosaic and uniform color process of satellite images is always an important problem in image processing. First of all using the bundle uniform color method and least squares mosaic method of GXL and the dodging function, the uniform transition of color and brightness can be realized in large area and multi-temporal satellite images. Secondly, using Color Mapping software to color mosaic images of 16bit to mosaic images of 8bit based on uniform color method with low resolution reference images. At last, qualitative and quantitative analytical methods are used respectively to analyse and evaluate satellite image after mosaic and uniformity coloring. The test reflects the correlation of mosaic images before and after coloring is higher than 95 % and image information entropy increases, texture features are enhanced which have been proved by calculation of quantitative indexes such as correlation coefficient and information entropy. Satellite image mosaic and color processing in large area has been well implemented.

  3. Gestational Weight Gain: Results from the Delta Healthy Sprouts Comparative Impact Trial.

    PubMed

    Thomson, Jessica L; Tussing-Humphreys, Lisa M; Goodman, Melissa H; Olender, Sarah E

    2016-01-01

    Introduction. Delta Healthy Sprouts trial was designed to test the comparative impact of two home visiting programs on weight status, dietary intake, and health behaviors of Southern African American women and their infants. Results pertaining to the primary outcome, gestational weight gain, are reported. Methods. Participants (n = 82), enrolled early in their second trimester of pregnancy, were randomly assigned to one of two treatment arms. Gestational weight gain, measured at six monthly home visits, was calculated by subtracting measured weight at each visit from self-reported prepregnancy weight. Weight gain was classified as under, within, or exceeding the Institute of Medicine recommendations based on prepregnancy body mass index. Chi-square tests and generalized linear mixed models were used to test for significant differences in percentages of participants within recommended weight gain ranges. Results. Differences in percentages of participants within the gestational weight gain guidelines were not significant between treatment arms across all visits. Conclusions. Enhancing the gestational nutrition and physical activity components of an existing home visiting program is feasible in a high risk population of primarily low income African American women. The impact of these enhancements on appropriate gestational weight gain is questionable given the more basic living needs of such women. This trial is registered with ClinicalTrials.gov NCT01746394, registered 4 December 2012.

  4. Strategic development of a multivariate calibration model for the uniformity testing of tablets by transmission NIR analysis.

    PubMed

    Sasakura, D; Nakayama, K; Sakamoto, T; Chikuma, T

    2015-05-01

    The use of transmission near infrared spectroscopy (TNIRS) is of particular interest in the pharmaceutical industry. This is because TNIRS does not require sample preparation and can analyze several tens of tablet samples in an hour. It has the capability to measure all relevant information from a tablet, while still on the production line. However, TNIRS has a narrow spectrum range and overtone vibrations often overlap. To perform content uniformity testing in tablets by TNIRS, various properties in the tableting process need to be analyzed by a multivariate prediction model, such as a Partial Least Square Regression modeling. One issue is that typical approaches require several hundred reference samples to act as the basis of the method rather than a strategically designed method. This means that many batches are needed to prepare the reference samples; this requires time and is not cost effective. Our group investigated the concentration dependence of the calibration model with a strategic design. Consequently, we developed a more effective approach to the TNIRS calibration model than the existing methodology.

  5. School Uniforms and Discourses on Childhood.

    ERIC Educational Resources Information Center

    Bodine, Ann

    2003-01-01

    This ethnographic study examined the introduction of school uniforms in the public schools of one California city. Findings indicated that the uniform issue intersected with issues such as student safety and violence, family stress, egalitarianism, competitive dressing, and a power struggle over shaping the childhood environment. It was concluded…

  6. Sudden gains in exposure therapy for obsessive-compulsive disorder.

    PubMed

    Collins, Lindsey M; Coles, Meredith E

    2017-06-01

    Prior research in the treatment of depression and anxiety has demonstrated that a sudden reduction in symptoms between two consecutive sessions (sudden gain) is related to lower post-treatment symptom severity (e.g. Hofmann, Schulz, Meuret, Moscovitch, & Suvak, 2006; Tang & DeRubeis, 1999). However, only one study has examined sudden gains in the treatment of obsessive compulsive disorder (OCD). In that study, one-third of the patients with OCD experienced a sudden gain (Aderka et al., 2012). Further, patients who had a sudden gain had lower clinician-rated OCD symptom severity post-treatment (Aderka et al., 2012). In replication, the current study examined the frequency, characteristics, and clinical impact of sudden gains in 27 OCD patients during exposure and response prevention (ERP) therapy. Fifty two percent of patients experienced a sudden gain. The mean magnitude of a sudden gain represented, on average, 61.4% of total symptom reduction. Following treatment, individuals who had experienced a sudden gain were rated as less severe on the clinical global impression scale, but they did not experience a greater reduction in OCD symptoms (pre-to post-treatment) than those without a sudden gain. None of the pre-treatment characteristics tested were found to significantly predict whether a patient would have a sudden gain. Additional research examining predictors of, and patterns of, change in OCD symptoms is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. A Science and Risk-Based Pragmatic Methodology for Blend and Content Uniformity Assessment.

    PubMed

    Sayeed-Desta, Naheed; Pazhayattil, Ajay Babu; Collins, Jordan; Doshi, Chetan

    2018-04-01

    This paper describes a pragmatic approach that can be applied in assessing powder blend and unit dosage uniformity of solid dose products at Process Design, Process Performance Qualification, and Continued/Ongoing Process Verification stages of the Process Validation lifecycle. The statistically based sampling, testing, and assessment plan was developed due to the withdrawal of the FDA draft guidance for industry "Powder Blends and Finished Dosage Units-Stratified In-Process Dosage Unit Sampling and Assessment." This paper compares the proposed Grouped Area Variance Estimate (GAVE) method with an alternate approach outlining the practicality and statistical rationalization using traditional sampling and analytical methods. The approach is designed to fit solid dose processes assuring high statistical confidence in both powder blend uniformity and dosage unit uniformity during all three stages of the lifecycle complying with ASTM standards as recommended by the US FDA.

  8. Symptoms related to new flight attendant uniforms.

    PubMed

    McNeely, Eileen; Staffa, Steven J; Mordukhovich, Irina; Coull, Brent

    2018-01-03

    Flight attendants at Alaska Airlines reported health symptoms after the introduction of new uniforms in 2011. The airline replaced the uniforms in 2014 without acknowledging harm. To understand possible uniform-related health effects, we analyzed self-reported health symptoms in crew who participated in the Harvard Flight Attendant Health Study between 2007 and 2015, the period before, during, and after the introduction of new uniforms. We calculated a standardized prevalence of respiratory, dermatological and allergic symptoms at baseline, as well as during and after uniform changes in 684 flight attendants with a varying number of surveys completed across each time point. We used Generalized Estimating Equations (GEE) to model the association between symptoms at baseline versus the exposure period after adjusting for age, gender and smoking status and weighting respondents for the likelihood of attrition over the course of the study period. We found the following symptom prevalence (per 100) increased after the introduction of new uniforms: multiple chemical sensitivity (10 vs 5), itchy/irritated skin (25 vs 13), rash/hives (23 vs 13), itchy eyes (24 vs 14), blurred vision (14 vs 6), sinus congestion (28 vs 24), ear pain (15 vs 12), sore throat (9 vs 5), cough (17 vs 7), hoarseness/loss of voice (12 vs 3), and shortness of breath (8 vs 3). The odds of several symptoms significantly increased compared to baseline after adjusting for potential confounders. This study found a relationship between health complaints and the introduction of new uniforms in this longitudinal occupational cohort.

  9. Radiation Response of Emerging High Gain, Low Noise Detectors

    NASA Technical Reports Server (NTRS)

    Becker, Heidi N.; Farr, William H; Zhu, David Q.

    2007-01-01

    Data illustrating the radiation response of emerging high gain, low noise detectors are presented. Ionizing dose testing of silicon internal discrete avalanche photodiodes, and 51-MeV proton testing of InGaAs/InAlAs avalanche photodiodes operated in Geiger mode are discussed.

  10. Outrunning major weight gain: a prospective study of 8,340consistent runners during 7 years of follow-up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Paul T.

    2006-01-06

    Background: Body weight increases with aging. Short-term,longitudinal exercise training studies suggest that increasing exerciseproduces acute weight loss, but it is not clear if the maintenance oflong-term, vigorous exercise attenuates age-related weight gain inproportion to the exercise dose. Methods: Prospective study of 6,119 maleand 2,221 female runners whose running distance changed less than 5 km/wkbetween their baseline and follow-up survey 7 years later. Results: Onaverage, men who ran modest (0-24 km/wk), intermediate (24-48 km/wk) orprolonged distances (>_48 km/wk) all gained weight throughage 64,however, those who ran ?48 km/wk had one-half the average annual weightgain of those who ran<24 km/wk. Age-related weightmore » gain, and itsreduction by running, were both greater in younger than older men. Incontrast, men s gain in waist circumference with age, and its reductionby running, were the same in older and younger men. Women increased theirbody weight and waist and hip circumferences over time, regardless ofage, which was also reduced in proportion to running distance. In bothsexes, running did not attenuate weight gain uniformly, but ratherdisproportionately prevented more extreme increases. Conclusion: Men andwomen who remain vigorously active gain less weight as they age and thereduction is in proportion to the exercise dose.« less

  11. School Uniform Policies in Public Schools

    ERIC Educational Resources Information Center

    Brunsma, David L.

    2006-01-01

    The movement for school uniforms in public schools continues to grow despite the author's research indicating little if any impact on student behavior, achievement, and self-esteem. The author examines the distribution of uniform policies by region and demographics, the impact of these policies on perceptions of school climate and safety, and…

  12. Green Design and Sustainable Development of School Uniforms

    NASA Astrophysics Data System (ADS)

    Cui, Yumei; Fang, Xuemeng; Zhou, Honglei

    2018-01-01

    Since the 1990s, the school uniform has gradually become an integral part of campus culture construction. A school uniform is not only an iconic symbol of students and a school, but also the carrier of campus culture, with special education function and cultural connotation. However in the same time, many problems exist in the design, making and material selection of school uniforms, in which, substandard fabric quality is the most serious problem. To ensure the quality, health and safety of school uniforms, in my opinion, priority should be given to green design and sustainable development in the design process of school uniforms, which will be more conducive to promoting the sound development of school uniforms. In today’s economic development, the globalization of mass production is no longer just a symbol of challenging the limits of human beings, but to explore the unlimited potential of human spiritual collaboration. If we want to have a better future on this planet, we need to completely redefine the key issue we need to address, that is, green design. The rise of green products is a great progress of human understanding and solving environmental problems. It is the inevitable development trend of commodity production, and will have a profound impact on human survival and development in the future. School uniform is an important part of campus culture construction. In order to not damage the health of primary and secondary school students, in the school uniform design and production process should follow the concept of “green design” to achieve the school uniform style, color, material design, a comprehensive “green” positioning.

  13. 7 CFR 51.1407 - Fairly uniform in color.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Fairly uniform in color. 51.1407 Section 51.1407... Definitions § 51.1407 Fairly uniform in color. Fairly uniform in color means that the shells do not show sufficient variation in color to materially detract from the general appearance of the lot. ...

  14. 7 CFR 51.1407 - Fairly uniform in color.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Fairly uniform in color. 51.1407 Section 51.1407... Definitions § 51.1407 Fairly uniform in color. Fairly uniform in color means that the shells do not show sufficient variation in color to materially detract from the general appearance of the lot. ...

  15. A novel digital image sensor with row wise gain compensation for Hyper Spectral Imager (HySI) application

    NASA Astrophysics Data System (ADS)

    Lin, Shengmin; Lin, Chi-Pin; Wang, Weng-Lyang; Hsiao, Feng-Ke; Sikora, Robert

    2009-08-01

    A 256x512 element digital image sensor has been developed which has a large pixel size, slow scan and low power consumption for Hyper Spectral Imager (HySI) applications. The device is a mixed mode, silicon on chip (SOC) IC. It combines analog circuitry, digital circuitry and optical sensor circuitry into a single chip. This chip integrates a 256x512 active pixel sensor array, a programming gain amplifier (PGA) for row wise gain setting, I2C interface, SRAM, 12 bit analog to digital convertor (ADC), voltage regulator, low voltage differential signal (LVDS) and timing generator. The device can be used for 256 pixels of spatial resolution and 512 bands of spectral resolution ranged from 400 nm to 950 nm in wavelength. In row wise gain readout mode, one can set a different gain on each row of the photo detector by storing the gain setting data on the SRAM thru the I2C interface. This unique row wise gain setting can be used to compensate the silicon spectral response non-uniformity problem. Due to this unique function, the device is suitable for hyper-spectral imager applications. The HySI camera located on-board the Chandrayaan-1 satellite, was successfully launched to the moon on Oct. 22, 2008. The device is currently mapping the moon and sending back excellent images of the moon surface. The device design and the moon image data will be presented in the paper.

  16. Effects of beam irregularity on uniform scanning

    NASA Astrophysics Data System (ADS)

    Kim, Chang Hyeuk; Jang, Sea duk; Yang, Tae-Keun

    2016-09-01

    An active scanning beam delivery method has many advantages in particle beam applications. For the beam is to be successfully delivered to the target volume by using the active scanning technique, the dose uniformity must be considered and should be at least 2.5% in the case of therapy application. During beam irradiation, many beam parameters affect the 2-dimensional uniformity at the target layer. A basic assumption in the beam irradiation planning stage is that the shape of the beam is symmetric and follows a Gaussian distribution. In this study, a pure Gaussian-shaped beam distribution was distorted by adding parasitic Gaussian distribution. An appropriate uniform scanning condition was deduced by using a quantitative analysis based on the gamma value of the distorted beam and 2-dimensional uniformities.

  17. Test set up description and performances for HAWAII-2RG detector characterization at ESTEC

    NASA Astrophysics Data System (ADS)

    Crouzet, P.-E.; ter Haar, J.; de Wit, F.; Beaufort, T.; Butler, B.; Smit, H.; van der Luijt, C.; Martin, D.

    2012-07-01

    In the frame work of the European Space Agency's Cosmic Vision program, the Euclid mission has the objective to map the geometry of the Dark Universe. Galaxies and clusters of galaxies will be observed in the visible and near-infrared wavelengths by an imaging and spectroscopic channel. For the Near Infrared Spectrometer instrument (NISP), the state-of-the-art HAWAII-2RG detectors will be used, associated with the SIDECAR ASIC readout electronic which will perform the image frame acquisitions. To characterize and validate the performance of these detectors, a test bench has been designed, tested and validated. This publication describes the pre-tests performed to build the set up dedicated to dark current measurements and tests requiring reasonably uniform light levels (such as for conversion gain measurements). Successful cryogenic and vacuum tests on commercial LEDs and photodiodes are shown. An optimized feed through in stainless steel with a V-groove to pot the flex cable connecting the SIDECAR ASIC to the room temperature board (JADE2) has been designed and tested. The test set up for quantum efficiency measurements consisting of a lamp, a monochromator, an integrating sphere and set of cold filters, and which is currently under construction will ensure a uniform illumination across the detector with variations lower than 2%. A dedicated spot projector for intra-pixel measurements has been designed and built to reach a spot diameter of 5 μm at 920nm with 2nm of bandwidth [1].

  18. 7 CFR 51.1447 - Fairly uniform in color.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... § 51.1447 Fairly uniform in color. Fairly uniform in color means that 90 percent or more of the kernels in the lot have skin color within the range of one or two color classifications. ... 7 Agriculture 2 2014-01-01 2014-01-01 false Fairly uniform in color. 51.1447 Section 51.1447...

  19. 7 CFR 51.1447 - Fairly uniform in color.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... § 51.1447 Fairly uniform in color. Fairly uniform in color means that 90 percent or more of the kernels in the lot have skin color within the range of one or two color classifications. ... 7 Agriculture 2 2013-01-01 2013-01-01 false Fairly uniform in color. 51.1447 Section 51.1447...

  20. 7 CFR 51.891 - Uniform in appearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Vinifera Type) 1 Definitions § 51.891 Uniform in appearance. Uniform in appearance means that not more than... materially detract from the appearance of the contents of the individual container, and that the stems are...

  1. 7 CFR 51.891 - Uniform in appearance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Vinifera Type) 1 Definitions § 51.891 Uniform in appearance. Uniform in appearance means that not more than... materially detract from the appearance of the contents of the individual container, and that the stems are...

  2. Gaining Control over Radiolytic Synthesis of Uniform Sub-3-nanometer Palladium Nanoparticles: Use of Aromatic Liquids in the Electron Microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abellan Baeza, Patricia; Parent, Lucas R.; Al Hasan, Naila M.

    2016-01-07

    Synthesizing nanomaterials of uniform shape and size is of critical importance to access and manipulate the novel structure-property relationships arising at the nanoscale. In this work we synthesize Pd nanoparticles with well-controlled size using in situ liquid-stage scanning transmission electron microscopy (STEM) and demonstrate a match between the reaction kinetics and products of the radiolytic and chemical syntheses of size-stabilized Pd nanoparticles. We quantify the effect of electron dose on the nucleation kinetics, and compare these results with in situ small angle X-ray scattering (SAXS) experiments investigating the effect of temperature during chemical synthesis. This work introduces methods for precisemore » control of nanoparticle synthesis in the STEM and provides a means to uncover the fundamental processes behind the size and shape stabilization of nanoparticles.« less

  3. Oxygen consumption along bed forms under losing and gaining streamflow conditions

    NASA Astrophysics Data System (ADS)

    De Falco, Natalie; Arnon, Shai; Boano, Fulvio

    2016-04-01

    Recent studies have demonstrated that bed forms are the most significant geomorphological structure that drives hyporheic exchange and biogeochemical processes in stream networks. Other studies also demonstrated that due to the hyporheic flow patterns within bed form, biogeochemical processes do not occur uniformly along and within the bed forms. The objective of this work was to systematically evaluate how losing or gaining flow conditions affect oxygen consumption by biofilm along sandy bed forms. We measured the effects of losing and gaining flow conditions on oxygen consumption by combining modeling and experiments in a novel laboratory flume system that enable the control of losing and gaining fluxes. Oxygen consumption was measured after growing a benthic biofilm fed with Sodium Benzoate (as a carbon source) and measuring the distribution of oxygen in the streambed with microelectrodes. The experimental results were analyzed using a novel code that calculates vertical profiles of reaction rates in the presence of hyporheic water fluxes. These experimental observations and modeling revealed that oxygen distribution varied along the bed forms. The zone of oxygen consumption (i.e. depth of penetration) was the largest at the upstream side of the bed form and the smallest in the lee side (at the lowest part of the bed form), regardless of the flow conditions. Also, the zone of oxygen consumption was the largest under losing conditions, the smallest under gaining conditions, and in-between under neutral conditions. The distribution of oxygen consumption rates determined with our new model will be also discussed. Our preliminary results enable us to show the importance of the coupling between flow conditions and oxygen consumption along bed forms and are expected to improve our understanding of nutrient cycling in streams.

  4. A Simplified Model for Detonation Based Pressure-Gain Combustors

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.

    2010-01-01

    A time-dependent model is presented which simulates the essential physics of a detonative or otherwise constant volume, pressure-gain combustor for gas turbine applications. The model utilizes simple, global thermodynamic relations to determine an assumed instantaneous and uniform post-combustion state in one of many envisioned tubes comprising the device. A simple, second order, non-upwinding computational fluid dynamic algorithm is then used to compute the (continuous) flowfield properties during the blowdown and refill stages of the periodic cycle which each tube undergoes. The exhausted flow is averaged to provide mixed total pressure and enthalpy which may be used as a cycle performance metric for benefits analysis. The simplicity of the model allows for nearly instantaneous results when implemented on a personal computer. The results compare favorably with higher resolution numerical codes which are more difficult to configure, and more time consuming to operate.

  5. Ultimate intra-wafer critical dimension uniformity control by using lithography and etch tool corrections

    NASA Astrophysics Data System (ADS)

    Kubis, Michael; Wise, Rich; Reijnen, Liesbeth; Viatkina, Katja; Jaenen, Patrick; Luca, Melisa; Mernier, Guillaume; Chahine, Charlotte; Hellin, David; Kam, Benjamin; Sobieski, Daniel; Vertommen, Johan; Mulkens, Jan; Dusa, Mircea; Dixit, Girish; Shamma, Nader; Leray, Philippe

    2016-03-01

    With shrinking design rules, the overall patterning requirements are getting aggressively tighter. For the 7-nm node and below, allowable CD uniformity variations are entering the Angstrom region (ref [1]). Optimizing inter- and intra-field CD uniformity of the final pattern requires a holistic tuning of all process steps. In previous work, CD control with either litho cluster or etch tool corrections has been discussed. Today, we present a holistic CD control approach, combining the correction capability of the etch tool with the correction capability of the exposure tool. The study is done on 10-nm logic node wafers, processed with a test vehicle stack patterning sequence. We include wafer-to-wafer and lot-to-lot variation and apply optical scatterometry to characterize the fingerprints. Making use of all available correction capabilities (lithography and etch), we investigated single application of exposure tool corrections and of etch tool corrections as well as combinations of both to reach the lowest CD uniformity. Results of the final pattern uniformity based on single and combined corrections are shown. We conclude on the application of this holistic lithography and etch optimization to 7nm High-Volume manufacturing, paving the way to ultimate within-wafer CD uniformity control.

  6. Does child and adolescent mental health in-service training result in equivalent knowledge gain among cadres of non-specialist health workers in Uganda? A pre-test post-test study.

    PubMed

    Akol, Angela; Nalugya, Joyce; Nshemereirwe, Sylvia; Babirye, Juliet N; Engebretsen, Ingunn Marie Stadskleiv

    2017-01-01

    Early identification and management of child and adolescent mental health (CAMH) disorders helps to avert mental illness in adulthood but a CAMH treatment gap exists in Uganda. CAMH integration into primary health care (PHC) through in-service training of non-specialist health workers (NSHW) using the World Health Organisation (WHO) Mental Health Gap Action Programme (mhGAP) Intervention Guide (IG) is a strategy to address this gap. However, results of such training are not supported by information on training development or delivery; and are undifferentiated by NSHW cadre. We aim to describe an in-service CAMH training for NSHW in Uganda and assess cadre-differentiated learning outcomes. Thirty-six clinical officers, nurses and midwives from 18 randomly selected PHC clinics in eastern Uganda were trained for 5 days on CAMH screening and referral using a curriculum based on the mhGAP-IG version 1.0 and PowerPoint slides from the International Association of Child and Adolescent Psychiatry and Allied Professions (IACAPAP). The residential training was evaluated through pre- and post- training tests of CAMH knowledge and attitudes using the participants' post-test scores; and the difference between pre-test and post-test scores. Two-tailed t-tests assessed differences in mean pre-test and post-test scores between the cadres; hierarchical linear regression tested the association between cadre and post test scores; and logistic regression evaluated the relationship between cadre and knowledge gain at three pre-determined cut off points. Thirty-three participants completed both pre-and post-tests. Improved mean scores from pre- to post-test were observed for both clinical officers (20% change) and nurse/midwives (18% change). Clinical officers had significantly higher mean test scores than nurses and midwives (p < 0.05) but cadre was not significantly associated with improvement in CAMH knowledge at the 10% (AOR 0.08; 95 CI [0.01, 1.19]; p = 0.066), 15% (AOR 0

  7. Development of a chromatographic method with multi-criteria decision making design for simultaneous determination of nifedipine and atenolol in content uniformity testing.

    PubMed

    Ahmed, Sameh; Alqurshi, Abdulmalik; Mohamed, Abdel-Maaboud Ismail

    2018-07-01

    A new robust and reliable high-performance liquid chromatography (HPLC) method with multi-criteria decision making (MCDM) approach was developed to allow simultaneous quantification of atenolol (ATN) and nifedipine (NFD) in content uniformity testing. Felodipine (FLD) was used as an internal standard (I.S.) in this study. A novel marriage between a new interactive response optimizer and a HPLC method was suggested for multiple response optimizations of target responses. An interactive response optimizer was used as a decision and prediction tool for the optimal settings of target responses, according to specified criteria, based on Derringer's desirability. Four independent variables were considered in this study: Acetonitrile%, buffer pH and concentration along with column temperature. Eight responses were optimized: retention times of ATN, NFD, and FLD, resolutions between ATN/NFD and NFD/FLD, and plate numbers for ATN, NFD, and FLD. Multiple regression analysis was applied in order to scan the influences of the most significant variables for the regression models. The experimental design was set to give minimum retention times, maximum resolution and plate numbers. The interactive response optimizer allowed prediction of optimum conditions according to these criteria with a good composite desirability value of 0.98156. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines with the aid of the experimental design. The developed MCDM-HPLC method showed superior robustness and resolution in short analysis time allowing successful simultaneous content uniformity testing of ATN and NFD in marketed capsules. The current work presents an interactive response optimizer as an efficient platform to optimize, predict responses, and validate HPLC methodology with tolerable design space for assay in quality control laboratories. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Design of a Mach-15 Total-Enthalpy Nozzle With Non-uniform Inflow Using Rotational MOC

    NASA Technical Reports Server (NTRS)

    Gaffney, Richard L., Jr.

    2004-01-01

    A new computer program to design nozzles with non-uniform inflow has been developed using the rotational method of characteristics (MOC). This program has been used to design a nozzle for the NASA's HYPULSE shock-expansion tunnel for use in scramjet engine tests at a Mach-15 flight-enthalpy condition. The nozzle has an area ratio of 9.5:1 that expands the inflow from Mach 6 along the centerline to Mach 8.7. Although the density and Mach number vary radially at the exit due to the non-uniformities of the inflow, the MOC procedure produces exit flow that is parallel and has uniform static pressure. The design has been verified with CFD which compares favorably with the MOC solution.

  9. School Dress Codes and Uniform Policies.

    ERIC Educational Resources Information Center

    Anderson, Wendell

    2002-01-01

    Opinions abound on what students should wear to class. Some see student dress as a safety issue; others see it as a student-rights issue. The issue of dress codes and uniform policies has been tackled in the classroom, the boardroom, and the courtroom. This Policy Report examines the whole fabric of the debate on dress codes and uniform policies…

  10. Temperature uniformity in hyperthermal tumor therapy

    NASA Technical Reports Server (NTRS)

    Harrison, G. H.; Robinson, J. E.; Samaras, G. M.

    1978-01-01

    Mouse mammary tumors heated by water bath or by microwave-induced hyperthermia exhibit a response that varies sharply with treatment temperature; therefore, uniform heating of the tumor is essential to quantitate the biological response as a function of temperature. C3H tumors implanted on the mouse flank were easily heated to uniformities within 0.1 C by using water baths. Cold spots up to 1 C below the desired treatment temperature were observed in the same tumors implanted on the hind leg. These cold spots were attributed to cooling by major blood vessels near the tumor. In this case temperature uniformity was achieved by the deposition of 2450 MHz microwave energy into the tumor volume by using parallel-opposed applicators.

  11. Uniforms, status and professional boundaries in hospital.

    PubMed

    Timmons, Stephen; East, Linda

    2011-11-01

    Despite their comparative neglect analytically, uniforms play a key role in the delineation of occupational boundaries and the formation of professional identity in healthcare. This paper analyses a change to the system of uniforms in one UK hospital, where management have required all professions (with the exception of doctors) to wear the same 'corporate' uniform. Focus groups were conducted with the professionals and patients. We analyse this initiative as a kind of McDonaldisation, seeking to create a new 'corporate' worker whose allegiance is principally to the organisation, rather than a profession. Our findings show how important uniforms are to their wearers, both in terms of the defence of professional boundaries and status, as well as the construction of professional identity. © 2011 The Authors. Sociology of Health & Illness © 2011 Foundation for the Sociology of Health & Illness/Blackwell Publishing Ltd.

  12. The metallic sphere in a uniform ac magnetic field: A simple and precise experiment for exploring eddy currents and non-destructive testing

    NASA Astrophysics Data System (ADS)

    Honke, Michael L.; Bidinosti, Christopher P.

    2018-06-01

    We describe a very simple experiment that utilizes standard laboratory equipment to measure the electromagnetic response of a metallic sphere exposed to a uniform ac magnetic field. Measurements were made for a variety of non-magnetic and magnetic metals, and in all cases the results fit very well with theory over the four orders of frequency (25 Hz to 102 kHz) explored here. Precise values of magnetic permeability and electrical conductivity can be extracted from fits to the data given the sphere radius only. The same apparatus is also used to explore the effects of geometry on eddy current generation as well as to demonstrate non-destructive testing through measurements on coins of different composition.

  13. The Uniform Reporting Program

    ERIC Educational Resources Information Center

    Mansfield, Stephen J.

    1976-01-01

    The Uniform Reporting Program of the American College Health Association generalizes on the problems of health service management and then identifies specific measures and programs to relieve those problems. (MM)

  14. Predicting True Reading Gains After Remedial Tutoring.

    ERIC Educational Resources Information Center

    Dahlke, Anita B.

    Using selected student variables, an attempt was made to predict retarded readers' true reading gains after remedial tutoring. The independent variables consisted of IQ and subtest scores obtained on the Wechsler Intelligence Scale for Children (WISC), pretutoring reading levels on the individually administered Diagnostic Reading Scales test, age,…

  15. Non-Uniform Cathode Emission Studies of a MIG Gun

    NASA Astrophysics Data System (ADS)

    Marchewka, C. D.; Shapiro, M. A.; Sirigiri, J. R.; Temkin, R. J.

    2004-11-01

    We present the initial results of the modeling of the effect of emission non-uniformity in 96 kV, 40 A Magnetron Injection Gun (MIG) of a 1.5 MW 110 GHz gyrotron using a 3D gun simulation code. The azimuthal emission nonuniformity can lead to increased mode competition and an overall decreased efficiency of the device [1]. The electron beam is modeled from the cathode to a downstream position where the velocity spread saturates using the AMAZE 3D suite of codes. After bench marking the results of the 3D code with 2D codes such as TRAK2D and EGUN, the emitter was modified to simulate asymmetric emission from the cathode to gain an understanding into the effects of inhomogeneous beam current density on the velocity spread and pitch factor of the electron beam. [1] G. S. Nusinovich, A.N. Vlasov, M. Botton, T. M. Antonsen, Jr., S. Cauffman, K. Felch, ``Effect of the azimuthal inhomogeneity of electron emission on gyrotron operation,'' Phys. Plasmas, vol. 8, no. 7, pp. 3473-3479, 2001

  16. A quantitative experimental phantom study on MRI image uniformity.

    PubMed

    Felemban, Doaa; Verdonschot, Rinus G; Iwamoto, Yuri; Uchiyama, Yuka; Kakimoto, Naoya; Kreiborg, Sven; Murakami, Shumei

    2018-05-23

    Our goal was to assess MR image uniformity by investigating aspects influencing said uniformity via a method laid out by the National Electrical Manufacturers Association (NEMA). Six metallic materials embedded in a glass phantom were scanned (i.e. Au, Ag, Al, Au-Ag-Pd alloy, Ti and Co-Cr alloy) as well as a reference image. Sequences included spin echo (SE) and gradient echo (GRE) scanned in three planes (i.e. axial, coronal, and sagittal). Moreover, three surface coil types (i.e. head and neck, Brain, and temporomandibular joint coils) and two image correction methods (i.e. surface coil intensity correction or SCIC, phased array uniformity enhancement or PURE) were employed to evaluate their effectiveness on image uniformity. Image uniformity was assessed using the National Electrical Manufacturers Association peak-deviation non-uniformity method. Results showed that temporomandibular joint coils elicited the least uniform image and brain coils outperformed head and neck coils when metallic materials were present. Additionally, when metallic materials were present, spin echo outperformed gradient echo especially for Co-Cr (particularly in the axial plane). Furthermore, both SCIC and PURE improved image uniformity compared to uncorrected images, and SCIC slightly surpassed PURE when metallic metals were present. Lastly, Co-Cr elicited the least uniform image while other metallic materials generally showed similar patterns (i.e. no significant deviation from images without metallic metals). Overall, a quantitative understanding of the factors influencing MR image uniformity (e.g. coil type, imaging method, metal susceptibility, and post-hoc correction method) is advantageous to optimize image quality, assists clinical interpretation, and may result in improved medical and dental care.

  17. INITIAL GAIN MEASUREMENTS OF A 800 NM SASE FEL, VISA.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    FRIGOLA,P.; MUROKH,A.; ET AL

    2000-08-13

    The VISA (Visible to Infrared SASE Amplifier) FEL is designed to obtain high gain at a radiation wavelength of 800nm. The FEL uses the high brightness electron beam of the Accelerator Test Facility (ATF), with energy of 72MeV. VISA uses a novel, 4 m long, strong focusing undulator with a gap of 6mm and a period of 1.8cm. To obtain large gain the beam and undulator axis have to be aligned to better than 50{micro}m. Results from initial measurements on the alignment, gain, and spectrum will be presented and compared to theoretical calculations and simulations.

  18. Image correlation microscopy for uniform illumination.

    PubMed

    Gaborski, T R; Sealander, M N; Ehrenberg, M; Waugh, R E; McGrath, J L

    2010-01-01

    Image cross-correlation microscopy is a technique that quantifies the motion of fluorescent features in an image by measuring the temporal autocorrelation function decay in a time-lapse image sequence. Image cross-correlation microscopy has traditionally employed laser-scanning microscopes because the technique emerged as an extension of laser-based fluorescence correlation spectroscopy. In this work, we show that image correlation can also be used to measure fluorescence dynamics in uniform illumination or wide-field imaging systems and we call our new approach uniform illumination image correlation microscopy. Wide-field microscopy is not only a simpler, less expensive imaging modality, but it offers the capability of greater temporal resolution over laser-scanning systems. In traditional laser-scanning image cross-correlation microscopy, lateral mobility is calculated from the temporal de-correlation of an image, where the characteristic length is the illuminating laser beam width. In wide-field microscopy, the diffusion length is defined by the feature size using the spatial autocorrelation function. Correlation function decay in time occurs as an object diffuses from its original position. We show that theoretical and simulated comparisons between Gaussian and uniform features indicate the temporal autocorrelation function depends strongly on particle size and not particle shape. In this report, we establish the relationships between the spatial autocorrelation function feature size, temporal autocorrelation function characteristic time and the diffusion coefficient for uniform illumination image correlation microscopy using analytical, Monte Carlo and experimental validation with particle tracking algorithms. Additionally, we demonstrate uniform illumination image correlation microscopy analysis of adhesion molecule domain aggregation and diffusion on the surface of human neutrophils.

  19. Uniform circular motion concept attainment through circle share learning model using real media

    NASA Astrophysics Data System (ADS)

    Ponimin; Suparmi; Sarwanto; Sunarno, W.

    2017-01-01

    Uniform circular motion is an important concept and has many applications in life. Student’s concept understanding of uniform circular motion is not optimal because the teaching learning is not carried out properly in accordance with the characteristics of the concept. To improve student learning outcomes required better teaching learning which is match with the characteristics of uniform circular motion. The purpose of the study is to determine the effect of real media and circle share model to the understanding of the uniform circular motion concept. The real media was used to visualize of uniform circular motion concept. The real media consists of toy car, round table and spring balance. Circle share model is a learning model through discussion sequentially and programmed. Each group must evaluate the worksheets of another group in a circular position. The first group evaluates worksheets the second group, the second group evaluates worksheets third group, and the end group evaluates the worksheets of the first group. Assessment of learning outcomes includes experiment worksheets and post-test of students. Based on data analysis we obtained some findings. First, students can explain the understanding of uniform circular motion whose angular velocity and speed is constant correctly. Second, students can distinguish the angular velocity and linear velocity correctly. Third, students can explain the direction of the linear velocity vector and the direction of the centripetal force vector. Fourth, the student can explain the influence of the mass, radius, and velocity toward the centripetal force. Fifth, students can explain the principle of combined of wheels. Sixth, teaching learning used circle share, can increase student activity, experimental results and efficiency of discussion time.

  20. Deviations from uniform power law scaling in nonstationary time series

    NASA Technical Reports Server (NTRS)

    Viswanathan, G. M.; Peng, C. K.; Stanley, H. E.; Goldberger, A. L.

    1997-01-01

    A classic problem in physics is the analysis of highly nonstationary time series that typically exhibit long-range correlations. Here we test the hypothesis that the scaling properties of the dynamics of healthy physiological systems are more stable than those of pathological systems by studying beat-to-beat fluctuations in the human heart rate. We develop techniques based on the Fano factor and Allan factor functions, as well as on detrended fluctuation analysis, for quantifying deviations from uniform power-law scaling in nonstationary time series. By analyzing extremely long data sets of up to N = 10(5) beats for 11 healthy subjects, we find that the fluctuations in the heart rate scale approximately uniformly over several temporal orders of magnitude. By contrast, we find that in data sets of comparable length for 14 subjects with heart disease, the fluctuations grow erratically, indicating a loss of scaling stability.

  1. Programmable Gain Amplifiers with DC Suppression and Low Output Offset for Bioelectric Sensors

    PubMed Central

    Carrera, Albano; de la Rosa, Ramón; Alonso, Alonso

    2013-01-01

    DC-offset and DC-suppression are key parameters in bioelectric amplifiers. However, specific DC analyses are not often explained. Several factors influence the DC-budget: the programmable gain, the programmable cut-off frequencies for high pass filtering and, the low cut-off values and the capacitor blocking issues involved. A new intermediate stage is proposed to address the DC problem entirely. Two implementations were tested. The stage is composed of a programmable gain amplifier (PGA) with DC-rejection and low output offset. Cut-off frequencies are selectable and values from 0.016 to 31.83 Hz were tested, and the capacitor deblocking is embedded in the design. Hence, this PGA delivers most of the required gain with constant low output offset, notwithstanding the gain or cut-off frequency selected. PMID:24084109

  2. An innovative validated spectrofluorimetric method for determination of Lisinopril in presence of hydrochlorothiazide; application to content uniformity testing

    NASA Astrophysics Data System (ADS)

    Derayea, Sayed M.; Badr El-din, Khalid M.; Mohammed, Fatma F.

    2018-01-01

    A new sensitive and discriminating spectrofluorimetric method has been developed and validated for determination of Lisinopril, one of the angiotensin converting enzyme inhibitors, in its pure bulk form and pharmaceutical tablets. The reaction of Lisinopril with ethylacetoacetate and formaldehyde in acidic buffered medium (pH 3.8) has yielded a pale yellow product that exhibited a high fluorescence measured at 438 nm after excitation at 350 nm. All the experimental parameters affecting the formation and stability of the produced fluorophore were carefully investigated and optimized to give the maximum sensitivity. The fluorescence intensity was directly proportional to the drug concentration in the range of 0.5-4.5 μg/mL with a limit of detection equal to 0.16 μg/mL. The method was successfully applied in the analysis of the commercially available pharmaceutical tablets containing the single drug or its binary mixtures with Hydrochlorothiazide. Furthermore, the developed procedure was adapted for studying the content uniformity test of some dosage forms containing the cited drug.

  3. Inflection point caustic problems and solutions for high-gain dual-shaped reflectors

    NASA Technical Reports Server (NTRS)

    Galindo-Israel, Victor; Veruttipong, Thavath; Imbriale, William; Rengarajan, Sembiam

    1990-01-01

    The singular nature of the uniform geometrical theory of diffraction (UTD) subreflector scattered field at the vicinity of the main reflector edge (for a high-gain antenna design) is investigated. It is shown that the singularity in the UTD edge-diffracted and slope-diffracted fields is due to the reflection distance parameter approaching infinity in the transition functions. While the geometrical optics (GO) and UTD edge-diffracted fields exhibit singularities of the same order, the edge slope-diffracted field singularity is more significant and is substantial for greater subreflector edge tapers. The diffraction analysis of such a subreflector in the vicinity of the main reflector edge has been carried out efficiently and accurately by a stationary phase evaluation of the phi-integral, whereas the theta-integral is carried out numerically. Computational results from UTD and physical optics (PO) analysis of a 34-m ground station dual-shaped reflector confirm the analytical formulations for both circularly symmetric and offset asymmetric subreflectors. It is concluded that the proposed PO(theta)GO(phi) technique can be used to study the spillover or noise temperature characteristics of a high-gain reflector antenna efficiently and accurately.

  4. 7 CFR 51.2085 - Fairly uniform color.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Fairly uniform color. 51.2085 Section 51.2085 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... color. Fairly uniform color means that the shells do not show excessive variation in color, whether...

  5. 7 CFR 51.2085 - Fairly uniform color.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Fairly uniform color. 51.2085 Section 51.2085 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... color. Fairly uniform color means that the shells do not show excessive variation in color, whether...

  6. 7 CFR 51.2085 - Fairly uniform color.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Fairly uniform color. 51.2085 Section 51.2085 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... color. Fairly uniform color means that the shells do not show excessive variation in color, whether...

  7. Optimal shortening of uniform covering arrays

    PubMed Central

    Rangel-Valdez, Nelson; Avila-George, Himer; Carrizalez-Turrubiates, Oscar

    2017-01-01

    Software test suites based on the concept of interaction testing are very useful for testing software components in an economical way. Test suites of this kind may be created using mathematical objects called covering arrays. A covering array, denoted by CA(N; t, k, v), is an N × k array over Zv={0,…,v-1} with the property that every N × t sub-array covers all t-tuples of Zvt at least once. Covering arrays can be used to test systems in which failures occur as a result of interactions among components or subsystems. They are often used in areas such as hardware Trojan detection, software testing, and network design. Because system testing is expensive, it is critical to reduce the amount of testing required. This paper addresses the Optimal Shortening of Covering ARrays (OSCAR) problem, an optimization problem whose objective is to construct, from an existing covering array matrix of uniform level, an array with dimensions of (N − δ) × (k − Δ) such that the number of missing t-tuples is minimized. Two applications of the OSCAR problem are (a) to produce smaller covering arrays from larger ones and (b) to obtain quasi-covering arrays (covering arrays in which the number of missing t-tuples is small) to be used as input to a meta-heuristic algorithm that produces covering arrays. In addition, it is proven that the OSCAR problem is NP-complete, and twelve different algorithms are proposed to solve it. An experiment was performed on 62 problem instances, and the results demonstrate the effectiveness of solving the OSCAR problem to facilitate the construction of new covering arrays. PMID:29267343

  8. Gimbals Drive and Control Electronics Design, Development and Testing of the LRO High Gain Antenna and Solar Array Systems

    NASA Technical Reports Server (NTRS)

    Chernyakov, Boris; Thakore, Kamal

    2010-01-01

    Launched June 18, 2009 on an Atlas V rocket, NASA's Lunar Reconnaissance Orbiter (LRO) is the first step in NASA's Vision for Space Exploration program and for a human return to the Moon. The spacecraft (SC) carries a wide variety of scientific instruments and provides an extraordinary opportunity to study the lunar landscape at resolutions and over time scales never achieved before. The spacecraft systems are designed to enable achievement of LRO's mission requirements. To that end, LRO's mechanical system employed two two-axis gimbal assemblies used to drive the deployment and articulation of the Solar Array System (SAS) and the High Gain Antenna System (HGAS). This paper describes the design, development, integration, and testing of Gimbal Control Electronics (GCE) and Actuators for both the HGAS and SAS systems, as well as flight testing during the on-orbit commissioning phase and lessons learned.

  9. An Assessment of the Uniform Funding Policy of DoD Directive 3200.11.

    DTIC Science & Technology

    1980-09-01

    34 Unpublished master’s thesis. GSM/SM/73-10, AFIT/EN, Wright-Patterson AFB OH 45433, 7 January 1974. Horngren , Charles T. Cost Accounting : A Management...reverse side if noceeeary aid identify by block number) Uniform Funding Policy Test Facilities Test and Evaluation Cost Accounting Accounting 20...segregated from overhead as a cost accounting device in both Government and industry. Historically, this distinc- tion has merely aided distribution of total

  10. Washing uniforms at home: adherence to hospital policy.

    PubMed

    Riley, Kate; Laird, Katie; Williams, John

    2015-02-20

    Infection control is a priority for all hospitals to reduce the spread of healthcare-associated infections (HCAIs). Textiles especially uniforms, are a possible route of HCAI transmission. There are protocols to ensure hospital laundry services meet accepted standards, however healthcare uniforms are laundered by staff at home and variations in practice occur. A questionnaire was used to conduct a service evaluation at four hospitals in different NHS trusts to determine how closely healthcare staff followed hospital guidelines on laundering and aftercare of uniforms at home. Responses showed that not all staff followed these guidelines; 44% of staff washed their uniforms below the recommended temperature of 60°C, which presents a potential route for cross-contamination and infection.

  11. Investigation of methods to produce a uniform cloud of fuel particles in a flame tube

    NASA Technical Reports Server (NTRS)

    Siegert, Clifford E.; Pla, Frederic G.; Rubinstein, Robert; Niezgoda, Thomas F.; Burns, Robert J.; Johnson, Jerome A.

    1990-01-01

    The combustion of a uniform, quiescent cloud of 30-micron fuel particles in a flame tube was proposed as a space-based, low-gravity experiment. The subject is the normal- and low-gravity testing of several methods to produce such a cloud, including telescoping propeller fans, air pumps, axial and quadrature acoustical speakers, and combinations of these devices. When operated in steady state, none of the methods produced an acceptably uniform cloud (+ or - 5 percent of the mean concentration), and voids in the cloud were clearly visible. In some cases, severe particle agglomeration was observed; however, these clusters could be broken apart by a short acoustic burst from an axially in-line speaker. Analyses and experiments reported elsewhere suggest that transient, acoustic mixing methods can enhance cloud uniformity while minimizing particle agglomeration.

  12. School Uniform Policies: Students' Views of Effectiveness.

    ERIC Educational Resources Information Center

    McCarthy, Teresa M.; Moreno, Josephine

    2001-01-01

    Focus-group interviews of New York City middle-school students about their perceptions of the effectiveness of the school-uniform policy. Finds that students' perceptions of the effects of school-uniform policy on school culture varied considerably with those intended by the principal. (Contains 40 references.) (PKP)

  13. Caustic Singularities Of High-Gain, Dual-Shaped Reflectors

    NASA Technical Reports Server (NTRS)

    Galindo, Victor; Veruttipong, Thavath W.; Imbriale, William A.; Rengarajan, Sambiam

    1991-01-01

    Report presents study of some sources of error in analysis, by geometric theory of diffraction (GTD), of performance of high-gain, dual-shaped antenna reflector. Study probes into underlying analytic causes of singularity, with view toward devising and testing practical methods to avoid problems caused by singularity. Hybrid physical optics (PO) approach used to study near-field spillover or noise-temperature characteristics of high-gain relector antenna efficiently and accurately. Report illustrates this approach and underlying principles by presenting numerical results, for both offset and symmetrical reflector systems, computed by GTD, PO, and PO/GO methods.

  14. Developmental gains in visuospatial memory predict gains in mathematics achievement.

    PubMed

    Li, Yaoran; Geary, David C

    2013-01-01

    Visuospatial competencies are related to performance in mathematical domains in adulthood, but are not consistently related to mathematics achievement in children. We confirmed the latter for first graders and demonstrated that children who show above average first-to-fifth grade gains in visuospatial memory have an advantage over other children in mathematics. The study involved the assessment of the mathematics and reading achievement of 177 children in kindergarten to fifth grade, inclusive, and their working memory capacity and processing speed in first and fifth grade. Intelligence was assessed in first grade and their second to fourth grade teachers reported on their in-class attentive behavior. Developmental gains in visuospatial memory span (d = 2.4) were larger than gains in the capacity of the central executive (d = 1.6) that in turn were larger than gains in phonological memory span (d = 1.1). First to fifth grade gains in visuospatial memory and in speed of numeral processing predicted end of fifth grade mathematics achievement, as did first grade central executive scores, intelligence, and in-class attentive behavior. The results suggest there are important individual differences in the rate of growth of visuospatial memory during childhood and that these differences become increasingly important for mathematics learning.

  15. Developmental Gains in Visuospatial Memory Predict Gains in Mathematics Achievement

    PubMed Central

    Li, Yaoran; Geary, David C.

    2013-01-01

    Visuospatial competencies are related to performance in mathematical domains in adulthood, but are not consistently related to mathematics achievement in children. We confirmed the latter for first graders and demonstrated that children who show above average first-to-fifth grade gains in visuospatial memory have an advantage over other children in mathematics. The study involved the assessment of the mathematics and reading achievement of 177 children in kindergarten to fifth grade, inclusive, and their working memory capacity and processing speed in first and fifth grade. Intelligence was assessed in first grade and their second to fourth grade teachers reported on their in-class attentive behavior. Developmental gains in visuospatial memory span (d = 2.4) were larger than gains in the capacity of the central executive (d = 1.6) that in turn were larger than gains in phonological memory span (d = 1.1). First to fifth grade gains in visuospatial memory and in speed of numeral processing predicted end of fifth grade mathematics achievement, as did first grade central executive scores, intelligence, and in-class attentive behavior. The results suggest there are important individual differences in the rate of growth of visuospatial memory during childhood and that these differences become increasingly important for mathematics learning. PMID:23936154

  16. Research on the preparation, uniformity and stability of mixed standard substance for rapid detection of goat milk composition.

    PubMed

    Zhu, Yuying; Wang, Jianmin; Wang, Cunfang

    2018-05-01

    Taking fresh goat milk as raw material after filtering, centrifuging, hollow fiber ultrafiltration, allocating formula, value detection and preparation processing, a set of 10 goat milk mixed standard substances was prepared on the basis of one-factor-at-a-time using a uniform design method, and its accuracy, uniformity and stability were evaluated by paired t-test and F-test of one-way analysis of variance. The results showed that three milk composition contents of these standard products were independent of each other, and the preparation using the quasi-level design method, and without emulsifier was the best program. Compared with detection value by cow milk standards for calibration fast analyzer, the calibration by goat milk mixed standard was more applicable to rapid detection of goat milk composition, detection value was more accurate and the deviation showed less error. Single factor analysis of variance showed that the uniformity and stability of the mixed standard substance were better; it could be stored for 15 days at 4°C. The uniformity and stability of the in-units and inter-units could meet the requirements of the preparation of national standard products. © 2018 Japanese Society of Animal Science.

  17. Determination of the Potential Benefit of Time-Frequency Gain Manipulation

    PubMed Central

    Anzalone, Michael C.; Calandruccio, Lauren; Doherty, Karen A.; Carney, Laurel H.

    2008-01-01

    Objective The purpose of this study was to determine the maximum benefit provided by a time-frequency gain-manipulation algorithm for noise-reduction (NR) based on an ideal detector of speech energy. The amount of detected energy necessary to show benefit using this type of NR algorithm was examined, as well as the necessary speed and frequency resolution of the gain manipulation. Design NR was performed using time-frequency gain manipulation, wherein the gains of individual frequency bands depended on the absence or presence of speech energy within each band. Three different experiments were performed: (1) NR using ideal detectors, (2) NR with nonideal detectors, and (3) NR with ideal detectors and different processing speeds and frequency resolutions. All experiments were performed using the Hearing-in-Noise test (HINT). A total of 6 listeners with normal hearing and 14 listeners with hearing loss were tested. Results HINT thresholds improved for all listeners with NR based on the ideal detectors used in Experiment I. The nonideal detectors of Experiment II required detection of at least 90% of the speech energy before an improvement was seen in HINT thresholds. The results of Experiment III demonstrated that relatively high temporal resolution (<100 msec) was required by the NR algorithm to improve HINT thresholds. Conclusions The results indicated that a single-microphone NR system based on time-frequency gain manipulation improved the HINT thresholds of listeners. However, to obtain benefit in speech intelligibility, the detectors used in such a strategy were required to detect an unrealistically high percentage of the speech energy and to perform the gain manipulations on a fast temporal basis. PMID:16957499

  18. Formulation design of oral pediatric Acetazolamide suspension: dose uniformity and physico-chemical stability study.

    PubMed

    Santoveña, Ana; Suárez-González, Javier; Martín-Rodríguez, Cristina; Fariña, José B

    2017-03-01

    The formulation of an active pharmaceutical ingredient (API) as oral solution or suspension in pediatrics is a habitual practice, due to the non-existence of many commercialized medicines in pediatric doses. It is also the simplest way to prepare and administer them to this vulnerable population. The design of a formulation that assures the dose and the system stability depends on the physico-chemical properties of the API. In this study, we formulate a class IV API, Acetazolamide (AZM) as suspension for oral administration to pediatric population. The suspension must comply attributes of quality, safety and efficacy for this route of administration. We use simple compounding procedures, as well as fewer pure excipients, as recommended for children. Mass and uniformity content assays and physical and chemical stability studies were performed. To quantify the API an UPLC method was used. We verified the physico-chemical stability of the suspensions and that they passed the mass test of the European Pharmacopeia (EP), but not the dose uniformity test. This reveals that AZM must be formulated as liquid forms with a more complex system of excipients (not usually indicated in pediatrics), or otherwise solid forms capable of assuring uniformity of mass and dose for every dosage unit.

  19. Impact of uniform electrode current distribution on ETF

    NASA Technical Reports Server (NTRS)

    Bents, D. J.

    1982-01-01

    The design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution are examined and the alternate consolidation design which occur are presented compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is given for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.

  20. Biological Efficacy of Permethrin Treatment on New U.S. Military Uniforms

    USDA-ARS?s Scientific Manuscript database

    The United States Army and United States Marine Corps (USMC) are fielding uniforms that incorporate fire resistant fibers into the uniform material. For the U.S. Army, the change in uniform composition to produce the Fire-Resistant Army Combat Uniform (FRACU) results in a uniform that does not reta...

  1. Blend uniformity evaluation during continuous mixing in a twin screw granulator by in-line NIR using a moving F-test.

    PubMed

    Fonteyne, Margot; Vercruysse, Jurgen; De Leersnyder, Fien; Besseling, Rut; Gerich, Ad; Oostra, Wim; Remon, Jean Paul; Vervaet, Chris; De Beer, Thomas

    2016-09-07

    This study focuses on the twin screw granulator of a continuous from-powder-to-tablet production line. Whereas powder dosing into the granulation unit is possible from a container of preblended material, a truly continuous process uses several feeders (each one dosing an individual ingredient) and relies on a continuous blending step prior to granulation. The aim of the current study was to investigate the in-line blending capacity of this twin screw granulator, equipped with conveying elements only. The feasibility of in-line NIR (SentroPAT, Sentronic GmbH, Dresden, Germany) spectroscopy for evaluating the blend uniformity of powders after the granulator was tested. Anhydrous theophylline was used as a tracer molecule and was blended with lactose monohydrate. Theophylline and lactose were both fed from a different feeder into the twin screw granulator barrel. Both homogeneous mixtures and mixing experiments with induced errors were investigated. The in-line spectroscopic analyses showed that the twin screw granulator is a useful tool for in-line blending in different conditions. The blend homogeneity was evaluated by means of a novel statistical method being the moving F-test method in which the variance between two blocks of collected NIR spectra is evaluated. The α- and β-error of the moving F-test are controlled by using the appropriate block size of spectra. The moving F-test method showed to be an appropriate calibration and maintenance free method for blend homogeneity evaluation during continuous mixing. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Revisiting the Issues: The Uniform Adoption Act.

    ERIC Educational Resources Information Center

    Hollinger, Joan Heifetz

    1995-01-01

    Discusses how a complex regulatory system, along with a lack of consensus about the functions served by adoption, produces uncertainty on many basic issues, including distinguishing lawful adoption versus illegal "baby-selling." The author recommends passage of more uniform state adoption laws, describes the 1994 Uniform Adoption Act,…

  3. Fisheye camera method for spatial non-uniformity corrections in luminous flux measurements with integrating spheres

    NASA Astrophysics Data System (ADS)

    Kokka, Alexander; Pulli, Tomi; Poikonen, Tuomas; Askola, Janne; Ikonen, Erkki

    2017-08-01

    This paper presents a fisheye camera method for determining spatial non-uniformity corrections in luminous flux measurements with integrating spheres. Using a fisheye camera installed into a port of an integrating sphere, the relative angular intensity distribution of the lamp under test is determined. This angular distribution is used for calculating the spatial non-uniformity correction for the lamp when combined with the spatial responsivity data of the sphere. The method was validated by comparing it to a traditional goniophotometric approach when determining spatial correction factors for 13 LED lamps with different angular spreads. The deviations between the spatial correction factors obtained using the two methods ranged from -0.15 % to 0.15%. The mean magnitude of the deviations was 0.06%. For a typical LED lamp, the expanded uncertainty (k = 2 ) for the spatial non-uniformity correction factor was evaluated to be 0.28%. The fisheye camera method removes the need for goniophotometric measurements in determining spatial non-uniformity corrections, thus resulting in considerable system simplification. Generally, no permanent modifications to existing integrating spheres are required.

  4. Gain weighted eigenspace assignment

    NASA Technical Reports Server (NTRS)

    Davidson, John B.; Andrisani, Dominick, II

    1994-01-01

    This report presents the development of the gain weighted eigenspace assignment methodology. This provides a designer with a systematic methodology for trading off eigenvector placement versus gain magnitudes, while still maintaining desired closed-loop eigenvalue locations. This is accomplished by forming a cost function composed of a scalar measure of error between desired and achievable eigenvectors and a scalar measure of gain magnitude, determining analytical expressions for the gradients, and solving for the optimal solution by numerical iteration. For this development the scalar measure of gain magnitude is chosen to be a weighted sum of the squares of all the individual elements of the feedback gain matrix. An example is presented to demonstrate the method. In this example, solutions yielding achievable eigenvectors close to the desired eigenvectors are obtained with significant reductions in gain magnitude compared to a solution obtained using a previously developed eigenspace (eigenstructure) assignment method.

  5. Constructing Uniformity: the Standardization of International Electromagnetic Measures, 1860-1912

    NASA Astrophysics Data System (ADS)

    Lagerstrom, Larry Randles

    Metrology gained much attention from electrical scientists and practitioners in the nineteenth and early twentieth centuries. Spurred by the expanding telegraph industries, they considered the construction and acceptance of a universal system of electromagnetic measures essential for the growth of science and technology. The task was not easy. Scientists and practitioners, having different concerns and needs, often found themselves at odds. National rivalries further obstructed the attainment of uniform measures. Under the auspices of a series of international electrical congresses and conferences between 1881 and 1908, the systembuilders succeeded in establishing an international system of practical electrical units and standards--the ohm, volt, ampere, coulomb, farad, joule, and watt--based on the centimeter-gram-second (CGS) system of measures. They had less success, however, with practical magnetic units. They had designed the system of electrical units to meet the needs of telegraphy. But the rise of the technologies of electrical power in the late nineteenth century made it difficult to define magnetic units that were both practical for the new technologies and coherent with the existing system of units. The international congress, as an institution, also gave them trouble. It lacked authority and stability and, in some cases, hindered the development of the system of units. More credit for the success of the systembuilders must go, paradoxically, to the national physical laboratories that arose in Germany, France, Great Britain, and the United States circa 1900. They enabled the standardization of international electromagnetic measures by narrowing the community of systembuilders to a small circle of elite experts. This historical process illustrates important aspects of the ways and means of standardization, of the technical and social construction of uniformity.

  6. 50 CFR 510.9 - Uniform pay guidelines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 11 2012-10-01 2012-10-01 false Uniform pay guidelines. 510.9 Section 510.9 Wildlife and Fisheries MARINE MAMMAL COMMISSION IMPLEMENTATION OF THE FEDERAL ADVISORY COMMITTEE ACT § 510.9 Uniform pay guidelines. (a) Compensation of members and staff of, and consultants to the...

  7. 50 CFR 510.9 - Uniform pay guidelines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 9 2011-10-01 2011-10-01 false Uniform pay guidelines. 510.9 Section 510.9 Wildlife and Fisheries MARINE MAMMAL COMMISSION IMPLEMENTATION OF THE FEDERAL ADVISORY COMMITTEE ACT § 510.9 Uniform pay guidelines. (a) Compensation of members and staff of, and consultants to the...

  8. 50 CFR 510.9 - Uniform pay guidelines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 11 2014-10-01 2014-10-01 false Uniform pay guidelines. 510.9 Section 510.9 Wildlife and Fisheries MARINE MAMMAL COMMISSION IMPLEMENTATION OF THE FEDERAL ADVISORY COMMITTEE ACT § 510.9 Uniform pay guidelines. (a) Compensation of members and staff of, and consultants to the...

  9. 50 CFR 510.9 - Uniform pay guidelines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 11 2013-10-01 2013-10-01 false Uniform pay guidelines. 510.9 Section 510.9 Wildlife and Fisheries MARINE MAMMAL COMMISSION IMPLEMENTATION OF THE FEDERAL ADVISORY COMMITTEE ACT § 510.9 Uniform pay guidelines. (a) Compensation of members and staff of, and consultants to the...

  10. 50 CFR 510.9 - Uniform pay guidelines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Uniform pay guidelines. 510.9 Section 510.9 Wildlife and Fisheries MARINE MAMMAL COMMISSION IMPLEMENTATION OF THE FEDERAL ADVISORY COMMITTEE ACT § 510.9 Uniform pay guidelines. (a) Compensation of members and staff of, and consultants to the...

  11. Measurement of Magnetic Field Uniformity For a Neutron Electric Dipole Moment Detector with New Lead Endcaps

    NASA Astrophysics Data System (ADS)

    Kulkarni, Anita; Filippone, Bradley; Slutsky, Simon; Swank, Christopher; Carr, Robert; Osthelder, Charles; Biswas, Aritra; Molina, Daniel

    2016-09-01

    Over the last several decades, physicists have been measuring the neutron electric dipole moment (nEDM) with greater and greater sensitivity. The latest experiment we are developing will have 100 times more sensitivity than the previous leading experiment. A nonzero nEDM could, among other consequences, explain the presence of more matter than antimatter in the universe. To measure the nEDM with high accuracy, it is necessary to have a very uniform magnetic field inside the detector since non-uniformities can create false signals via the geometric phase effect. One way to improve field uniformity is to add superconducting lead endcaps to the detector, which constrain the fields at their surfaces to be parallel to them. Here, we test how the endcaps improve field uniformity by measuring the magnetic field at various points in a 1/3-scale experimental volume, inferring what the field must be at all other points, and calculating gradients in the field. This knowledge could help guide further steps needed to improve field uniformity and characterize limitations to the sensitivity of nEDM measurements for the full-scale experiment. Rose Hills Foundation, National Science Foundation Grant 1506459, and Department of Energy.

  12. CD uniformity control for thick resist process

    NASA Astrophysics Data System (ADS)

    Huang, Chi-hao; Liu, Yu-Lin; Wang, Weihung; Yang, Mars; Yang, Elvis; Yang, T. H.; Chen, K. C.

    2017-03-01

    In order to meet the increasing storage capacity demand and reduce bit cost of NAND flash memories, 3D stacked flash cell array has been proposed. In constructing 3D NAND flash memories, the higher bit number per area is achieved by increasing the number of stacked layers. Thus the so-called "staircase" patterning to form electrical connection between memory cells and word lines has become one of the primarily critical processes in 3D memory manufacture. To provide controllable critical dimension (CD) with good uniformity involving thick photo-resist has also been of particular concern for staircase patterning. The CD uniformity control has been widely investigated with relatively thinner resist associated with resolution limit dimension but thick resist coupling with wider dimension. This study explores CD uniformity control associated with thick photo-resist processing. Several critical parameters including exposure focus, exposure dose, baking condition, pattern size and development recipe, were found to strongly correlate with the thick photo-resist profile accordingly affecting the CD uniformity control. To minimize the within-wafer CD variation, the slightly tapered resist profile is proposed through well tailoring the exposure focus and dose together with optimal development recipe. Great improvements on DCD (ADI CD) and ECD (AEI CD) uniformity as well as line edge roughness were achieved through the optimization of photo resist profile.

  13. Gain Scheduling for the Orion Launch Abort Vehicle Controller

    NASA Technical Reports Server (NTRS)

    McNamara, Sara J.; Restrepo, Carolina I.; Madsen, Jennifer M.; Medina, Edgar A.; Proud, Ryan W.; Whitley, Ryan J.

    2011-01-01

    One of NASAs challenges for the Orion vehicle is the control system design for the Launch Abort Vehicle (LAV), which is required to abort safely at any time during the atmospheric ascent portion of ight. The focus of this paper is the gain design and scheduling process for a controller that covers the wide range of vehicle configurations and flight conditions experienced during the full envelope of potential abort trajectories from the pad to exo-atmospheric flight. Several factors are taken into account in the automation process for tuning the gains including the abort effectors, the environmental changes and the autopilot modes. Gain scheduling is accomplished using a linear quadratic regulator (LQR) approach for the decoupled, simplified linear model throughout the operational envelope in time, altitude and Mach number. The derived gains are then implemented into the full linear model for controller requirement validation. Finally, the gains are tested and evaluated in a non-linear simulation using the vehicles ight software to ensure performance requirements are met. An overview of the LAV controller design and a description of the linear plant models are presented. Examples of the most significant challenges with the automation of the gain tuning process are then discussed. In conclusion, the paper will consider the lessons learned through out the process, especially in regards to automation, and examine the usefulness of the gain scheduling tool and process developed as applicable to non-Orion vehicles.

  14. Evaluation of nitrous oxide as a substitute for sulfur hexafluoride to reduce global warming impacts of ANSI/HPS N13.1 gaseous uniformity testing

    DOE PAGES

    Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.; ...

    2017-12-12

    The ANSI/HPS N13.1–2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF 6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N 2O) was evaluated as a potential replacement to SF 6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position,more » and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF 6 modeling corroborated N 2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N 2O testing to SF 6 testing in the context of stack qualification tests. In conclusion, the results demonstrate that N 2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.« less

  15. Evaluation of nitrous oxide as a substitute for sulfur hexafluoride to reduce global warming impacts of ANSI/HPS N13.1 gaseous uniformity testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.

    The ANSI/HPS N13.1–2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF 6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N 2O) was evaluated as a potential replacement to SF 6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position,more » and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF 6 modeling corroborated N 2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N 2O testing to SF 6 testing in the context of stack qualification tests. In conclusion, the results demonstrate that N 2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.« less

  16. Evaluation of nitrous oxide as a substitute for sulfur hexafluoride to reduce global warming impacts of ANSI/HPS N13.1 gaseous uniformity testing

    NASA Astrophysics Data System (ADS)

    Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.; Recknagle, Kurtis P.; Flaherty, Julia E.; Antonio, Ernest J.; Glissmeyer, John A.

    2018-03-01

    The ANSI/HPS N13.1-2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N2O) was evaluated as a potential replacement to SF6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position, and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF6 modeling corroborated N2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N2O testing to SF6 testing in the context of stack qualification tests. The results demonstrate that N2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.

  17. New reversing design method for LED uniform illumination.

    PubMed

    Wang, Kai; Wu, Dan; Qin, Zong; Chen, Fei; Luo, Xiaobing; Liu, Sheng

    2011-07-04

    In light-emitting diode (LED) applications, it is becoming a big issue that how to optimize light intensity distribution curve (LIDC) and design corresponding optical component to achieve uniform illumination when distance-height ratio (DHR) is given. A new reversing design method is proposed to solve this problem, including design and optimization of LIDC to achieve high uniform illumination and a new algorithm of freeform lens to generate the required LIDC by LED light source. According to this method, two new LED modules integrated with freeform lenses are successfully designed for slim direct-lit LED backlighting with thickness of 10mm, and uniformities of illuminance increase from 0.446 to 0.915 and from 0.155 to 0.887 when DHRs are 2 and 3 respectively. Moreover, the number of new LED modules dramatically decreases to 1/9 of the traditional LED modules while achieving similar uniform illumination in backlighting. Therefore, this new method provides a practical and simple way for optical design of LED uniform illumination when DHR is much larger than 1.

  18. Student Dress Codes and Uniforms. Research Brief

    ERIC Educational Resources Information Center

    Johnston, Howard

    2009-01-01

    According to an Education Commission of the States "Policy Report", research on the effects of dress code and school uniform policies is inconclusive and mixed. Some researchers find positive effects; others claim no effects or only perceived effects. While no state has legislatively mandated the wearing of school uniforms, 28 states and…

  19. 44 CFR 12.18 - Uniform pay guidelines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Uniform pay guidelines. 12.18... HOMELAND SECURITY GENERAL ADVISORY COMMITTEES § 12.18 Uniform pay guidelines. (a) Members. Subject to the provisions of this section, the pay of any member of an advisory committee shall be fixed at the daily...

  20. Dose Uniformity of Scored and Unscored Tablets: Application of the FDA Tablet Scoring Guidance for Industry.

    PubMed

    Ciavarella, Anthony B; Khan, Mansoor A; Gupta, Abhay; Faustino, Patrick J

    This U.S. Food and Drug Administration (FDA) laboratory study examines the impact of tablet splitting, the effect of tablet splitters, and the presence of a tablet score on the dose uniformity of two model drugs. Whole tablets were purchased from five manufacturers for amlodipine and six for gabapentin. Two splitters were used for each drug product, and the gabapentin tablets were also split by hand. Whole and split amlodipine tablets were tested for content uniformity following the general chapter of the United States Pharmacopeia (USP) Uniformity of Dosage Units <905>, which is a requirement of the new FDA Guidance for Industry on tablet scoring. The USP weight variation method was used for gabapentin split tablets based on the recommendation of the guidance. All whole tablets met the USP acceptance criteria for the Uniformity of Dosage Units. Variation in whole tablet content ranged from 0.5 to 2.1 standard deviation (SD) of the percent label claim. Splitting the unscored amlodipine tablets resulted in a significant increase in dose variability of 6.5-25.4 SD when compared to whole tablets. Split tablets from all amlodipine drug products did not meet the USP acceptance criteria for content uniformity. Variation in the weight for gabapentin split tablets was greater than the whole tablets, ranging from 1.3 to 9.3 SD. All fully scored gabapentin products met the USP acceptance criteria for weight variation. Size, shape, and the presence or absence of a tablet score can affect the content uniformity and weight variation of amlodipine and gabapentin tablets. Tablet splitting produced higher variability. Differences in dose variability and fragmentation were observed between tablet splitters and hand splitting. These results are consistent with the FDA's concerns that tablet splitting can have an effect on the amount of drug present in a split tablet and available for absorption. Tablet splitting has become a very common practice in the United States and throughout

  1. 34 CFR 462.4 - What are the transition rules for using tests to measure educational gain for the National...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... measure educational gain for the National Reporting System for Adult Education (NRS)? 462.4 Section 462.4... ADULT EDUCATION, DEPARTMENT OF EDUCATION MEASURING EDUCATIONAL GAIN IN THE NATIONAL REPORTING SYSTEM FOR... gain for the National Reporting System for Adult Education (NRS)? A State or a local eligible provider...

  2. Trends and determinants of weight gains among OECD countries: an ecological study.

    PubMed

    Nghiem, S; Vu, X-B; Barnett, A

    2018-06-01

    Obesity has become a global issue with abundant evidence to indicate that the prevalence of obesity in many nations has increased over time. The literature also reports a strong association between obesity and economic development, but the trend that obesity growth rates may converge over time has not been examined. We propose a conceptual framework and conduct an ecological analysis on the relationship between economic development and weight gain. We also test the hypothesis that weight gain converges among countries over time and examine determinants of weight gains. This is a longitudinal study of 34 Organisation for Economic Cooperation and Development (OECD) countries in the years 1980-2008 using publicly available data. We apply a dynamic economic growth model to test the hypothesis that the rate of weight gains across countries may converge over time. We also investigate the determinants of weight gains using a longitudinal regression tree analysis. We do not find evidence that the growth rates of body weight across countries converged for all countries. However, there were groups of countries in which the growth rates of body weight converge, with five groups for males and seven groups for females. The predicted growth rates of body weight peak when gross domestic product (GDP) per capita reaches US$47,000 for males and US$37,000 for females in OECD countries. National levels of consumption of sugar, fat and alcohol were the most important contributors to national weight gains. National weight gains follow an inverse U-shape curve with economic development. Excessive calorie intake is the main contributor to weight gains. Copyright © 2018 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  3. Improved sensitivity via layered-double-hydroxide-uniformity-dependent chemiluminescence.

    PubMed

    Li, Zenghe; Wang, Dan; Yuan, Zhiqin; Lu, Chao

    2016-12-01

    In the last two decades nanoparticles have been widely applied to enhance chemiluminescence (CL). The morphology of nanoparticles has an important influence on nanoparticle-amplified CL. However, studies of nanoparticle-amplified CL focus mainly on the size and shape effects, and no attempt has been made to explore the influence of uniformity in nanoparticle-amplified CL processes. In this study we have investigated nanoparticle uniformity in the luminol-H 2 O 2 CL system using layered double hydroxides (LDHs) as a model material. The results demonstrated that the uniformity of LDHs played a key role in CL amplification. A possible mechanism is that LDHs with high uniformity possess abundant catalytic active sites, which results in high CL intensity. Meanwhile, the sensitivity for H 2 O 2 detection was increased by one order of magnitude (1.0 nM). Moreover, the uniform-LDH-amplified luminol CL could be applied to selective detection of glucose in human plasma samples. Furthermore, such a uniformity-dependent CL enhancement effect could adapted to other redox CL systems-for example, the peroxynitrous acid (ONOOH) CL system.

  4. 22 CFR 214.42 - Uniform pay guidelines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Uniform pay guidelines. 214.42 Section 214.42... Advisory Committees § 214.42 Uniform pay guidelines. (a) A.I.D. follows OMB/CSC guidelines in section 11 of OMB Circular A-63 in establishing rates of pay for advisory committee members, staffs, and consultants...

  5. Linking of uniform random polygons in confined spaces

    NASA Astrophysics Data System (ADS)

    Arsuaga, J.; Blackstone, T.; Diao, Y.; Karadayi, E.; Saito, M.

    2007-03-01

    In this paper, we study the topological entanglement of uniform random polygons in a confined space. We derive the formula for the mean squared linking number of such polygons. For a fixed simple closed curve in the confined space, we rigorously show that the linking probability between this curve and a uniform random polygon of n vertices is at least 1-O\\big(\\frac{1}{\\sqrt{n}}\\big) . Our numerical study also indicates that the linking probability between two uniform random polygons (in a confined space), of m and n vertices respectively, is bounded below by 1-O\\big(\\frac{1}{\\sqrt{mn}}\\big) . In particular, the linking probability between two uniform random polygons, both of n vertices, is bounded below by 1-O\\big(\\frac{1}{n}\\big) .

  6. Black Versus Gray T-Shirts: Comparison of Spectrophotometric and Other Biophysical Properties of Physical Fitness Uniforms and Modeled Heat Strain and Thermal Comfort

    DTIC Science & Technology

    2016-09-01

    test method for measuring the thermal insulation of clothing using a heated manikin. 2010. 2. ASTM International. F2370-10 Standard test method for...PROPERTIES OF PHYSICAL FITNESS UNIFORMS AND MODELED HEAT STRAIN AND THERMAL COMFORT DISCLAIMER The opinions or assertions contained herein are the...SHIRTS: COMPARISON OF SPECTROPHOTOMETRIC AND OTHER BIOPHYSICAL PROPERTIES OF PHYSICAL FITNESS UNIFORMS AND MODELED HEAT STRAIN AND THERMAL COMFORT

  7. Optical design and fabrication of palm/fingerprint uniform illumination system with a high-power near-infrared light-emitting diode.

    PubMed

    Jing, Lei; Wang, Yao; Zhao, Huifu; Ke, Hongliang; Wang, Xiaoxun; Gao, Qun

    2017-06-10

    In order to meet the requirements of uniform illumination for optical palm/fingerprint instruments and overcome the shortcomings of the poor uniform illumination on the working plane of the optical palm/fingerprint prism, a novel secondary optical lens with a free-form surface, compact structure, and high uniformity is presented in this paper. The design of the secondary optical lens is based on emission properties of the near-infrared light-emitting diode (LED) and basic principles of non-imaging optics, especially considering the impact of the thickness of the prism in the design. Through the numerical solution of Snell's law in geometric optics, we obtain the profile of the free-form surface of the lens. Using the optical software TracePro, we trace and simulate the illumination system. The results show that the uniformity is 89.8% on the working plane of the prism, and the test results show that the actual uniformity reaches 85.7% in the experiment, which provides an effective way for realizing a highly uniform illumination system with high-power near-infrared LED.

  8. Postcessation weight gain concern as a barrier to smoking cessation: Assessment considerations and future directions.

    PubMed

    Germeroth, Lisa J; Levine, Michele D

    2018-01-01

    Concern about postcessation weight gain may be one potential barrier to quitting smoking. In this 'mini-review' of recent literature, we summarize findings on the relationship between postcessation weight gain concern and smoking cessation, and evaluate varied use of postcessation weight gain concern assessments and potential moderators of the postcessation weight gain concern-cessation association. We conducted a search using the terms "smoking" OR "smoking cessation" AND "weight concern" for articles published between January 1, 2011 and December 31, 2016. We identified 17 studies assessing postcessation weight gain concern, seven of which evaluated the postcessation weight gain concern-cessation association. The relationship between postcessation weight gain concern and smoking cessation was mixed. Recent studies varied in their assessments of postcessation weight gain concern, many of which were not validated and assessed correlates of this construct. Studies varied in their adjustment of demographic (e.g., sex), smoking-specific (e.g., smoking level), and weight-specific (e.g., body mass index) variables. The use of non-validated assessments and variability in testing covariates/moderators may contribute to conflicting results regarding the postcessation weight gain concern-cessation relationship. We recommend validating an assessment of postcessation weight gain concern, maintaining vigilance in testing and reporting covariates/moderators, and investigating trajectories of this construct over time and by smoking status to inform future assessment and intervention efforts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Cold-Water Immersion for Hyperthermic Humans Wearing American Football Uniforms

    PubMed Central

    Miller, Kevin C.; Swartz, Erik E.; Long, Blaine C.

    2015-01-01

    Context Current treatment recommendations for American football players with exertional heatstroke are to remove clothing and equipment and immerse the body in cold water. It is unknown if wearing a full American football uniform during cold-water immersion (CWI) impairs rectal temperature (Trec) cooling or exacerbates hypothermic afterdrop. Objective To determine the time to cool Trec from 39.5°C to 38.0°C while participants wore a full American football uniform or control uniform during CWI and to determine the uniform's effect on Trec recovery postimmersion. Design Crossover study. Setting Laboratory. Patients or Other Participants A total of 18 hydrated, physically active, unacclimated men (age = 22 ± 3 years, height = 178.8 ± 6.8 cm, mass = 82.3 ± 12.6 kg, body fat = 13% ± 4%, body surface area = 2.0 ± 0.2 m2). Intervention(s) Participants wore the control uniform (undergarments, shorts, crew socks, tennis shoes) or full uniform (control plus T-shirt; tennis shoes; jersey; game pants; padding over knees, thighs, and tailbone; helmet; and shoulder pads). They exercised (temperature approximately 40°C, relative humidity approximately 35%) until Trec reached 39.5°C. They removed their T-shirts and shoes and were then immersed in water (approximately 10°C) while wearing each uniform configuration; time to cool Trec to 38.0°C (in minutes) was recorded. We measured Trec (°C) every 5 minutes for 30 minutes after immersion. Main Outcome Measure(s) Time to cool from 39.5°C to 38.0°C and Trec. Results The Trec cooled to 38.0°C in 6.19 ± 2.02 minutes in full uniform and 8.49 ± 4.78 minutes in control uniform (t17 = −2.1, P = .03; effect size = 0.48) corresponding to cooling rates of 0.28°C·min−1 ± 0.12°C·min−1 in full uniform and 0.23°C·min−1 ± 0.11°C·min−1 in control uniform (t17 = 1.6, P = .07, effect size = 0.44). The Trec postimmersion recovery did not differ between conditions over time (F1,17 = 0.6, P = .59). Conclusions We

  10. Cold-Water Immersion for Hyperthermic Humans Wearing American Football Uniforms.

    PubMed

    Miller, Kevin C; Swartz, Erik E; Long, Blaine C

    2015-08-01

    Current treatment recommendations for American football players with exertional heatstroke are to remove clothing and equipment and immerse the body in cold water. It is unknown if wearing a full American football uniform during cold-water immersion (CWI) impairs rectal temperature (Trec) cooling or exacerbates hypothermic afterdrop. To determine the time to cool Trec from 39.5°C to 38.0°C while participants wore a full American football uniform or control uniform during CWI and to determine the uniform's effect on Trec recovery postimmersion. Crossover study. Laboratory. A total of 18 hydrated, physically active, unacclimated men (age = 22 ± 3 years, height = 178.8 ± 6.8 cm, mass = 82.3 ± 12.6 kg, body fat = 13% ± 4%, body surface area = 2.0 ± 0.2 m(2)). Participants wore the control uniform (undergarments, shorts, crew socks, tennis shoes) or full uniform (control plus T-shirt; tennis shoes; jersey; game pants; padding over knees, thighs, and tailbone; helmet; and shoulder pads). They exercised (temperature approximately 40°C, relative humidity approximately 35%) until Trec reached 39.5°C. They removed their T-shirts and shoes and were then immersed in water (approximately 10°C) while wearing each uniform configuration; time to cool Trec to 38.0°C (in minutes) was recorded. We measured Trec (°C) every 5 minutes for 30 minutes after immersion. Time to cool from 39.5°C to 38.0°C and Trec. The Trec cooled to 38.0°C in 6.19 ± 2.02 minutes in full uniform and 8.49 ± 4.78 minutes in control uniform (t17 = -2.1, P = .03; effect size = 0.48) corresponding to cooling rates of 0.28°C·min(-1) ± 0.12°C·min(-1) in full uniform and 0.23°C·min(-1) ± 0.11°C·min(-1) in control uniform (t17 = 1.6, P = .07, effect size = 0.44). The Trec postimmersion recovery did not differ between conditions over time (F1,17 = 0.6, P = .59). We speculate that higher skin temperatures before CWI, less shivering, and greater conductive cooling explained the faster cooling

  11. Coded aperture imaging with uniformly redundant arrays

    DOEpatents

    Fenimore, Edward E.; Cannon, Thomas M.

    1980-01-01

    A system utilizing uniformly redundant arrays to image non-focusable radiation. The uniformly redundant array is used in conjunction with a balanced correlation technique to provide a system with no artifacts such that virtually limitless signal-to-noise ratio is obtained with high transmission characteristics. Additionally, the array is mosaicked to reduce required detector size over conventional array detectors.

  12. Coded aperture imaging with uniformly redundant arrays

    DOEpatents

    Fenimore, Edward E.; Cannon, Thomas M.

    1982-01-01

    A system utilizing uniformly redundant arrays to image non-focusable radiation. The uniformly redundant array is used in conjunction with a balanced correlation technique to provide a system with no artifacts such that virtually limitless signal-to-noise ratio is obtained with high transmission characteristics. Additionally, the array is mosaicked to reduce required detector size over conventional array detectors.

  13. Computational fluid dynamic (CFD) investigation of thermal uniformity in a thermal cycling based calibration chamber for MEMS

    NASA Astrophysics Data System (ADS)

    Gui, Xulong; Luo, Xiaobing; Wang, Xiaoping; Liu, Sheng

    2015-12-01

    Micro-electrical-mechanical system (MEMS) has become important for many industries such as automotive, home appliance, portable electronics, especially with the emergence of Internet of Things. Volume testing with temperature compensation has been essential in order to provide MEMS based sensors with repeatability, consistency, reliability, and durability, but low cost. Particularly, in the temperature calibration test, temperature uniformity of thermal cycling based calibration chamber becomes more important for obtaining precision sensors, as each sensor is different before the calibration. When sensor samples are loaded into the chamber, we usually open the door of the chamber, then place fixtures into chamber and mount the samples on the fixtures. These operations may affect temperature uniformity in the chamber. In order to study the influencing factors of sample-loading on the temperature uniformity in the chamber during calibration testing, numerical simulation work was conducted first. Temperature field and flow field were simulated in empty chamber, chamber with open door, chamber with samples, and chamber with fixtures, respectively. By simulation, it was found that opening chamber door, sample size and number of fixture layers all have effects on flow field and temperature field. By experimental validation, it was found that the measured temperature value was consistent with the simulated temperature value.

  14. Longitudinal uniformity, time performances and irradiation test of pure CsI crystals

    NASA Astrophysics Data System (ADS)

    Angelucci, M.; Atanova, O.; Baccaro, S.; Cemmi, A.; Cordelli, M.; Donghia, R.; Giovannella, S.; Happacher, F.; Miscetti, S.; Sarra, I.; Soleti, S. R.

    2016-07-01

    To study an alternative to BaF2, as the crystal choice for the Mu2e calorimeter, 13 pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response uniformity (LRU), when read with a UV extended PMT. The crystals show a LY of 100 p.e./MeV ( 150 p.e./MeV) when wrapped with Tyvek and coupled to the PMT without (with) optical grease. The LRU is well represented by a linear slope that is on average δ -0.6%/cm. The timing performances of the Opto Materials crystal, read with a UV extended MPPC, have been evaluated with minimum ionizing particles. A timing resolution of 330 ps ( 440 ps) is achieved when connecting the photosensor to the MPPC with (without) optical grease. The crystal radiation hardness to a ionization dose has also been studied for one pure CsI crystal from SICCAS. After exposing it to a dose of 900 Gy, a decrease of 33% in the LY is observed while the LRU remains unchanged.

  15. Lack of international uniformity in assessing color vision deficiency in professional pilots.

    PubMed

    Watson, Dougal B

    2014-02-01

    Color is an important characteristic of the aviation environment. Pilots must rapidly and accurately differentiate and identify colors. The medical standards published by the International Civil Aviation Organization (ICAO) require that pilots have "the ability to perceive readily those colors the perception of which is necessary for the safe performance of duties." The general wording of that color vision (CV) standard, coupled with the associated flexibility provisions, allows for different approaches to the assessment of color vision deficient (CVD) pilots. Data was gathered and analyzed regarding medical assessment practices applied by different countries to CVD pilots. Data was obtained from 78 countries, representing 78% of the population and 92% of the aviation activity of the world. That data indicates wide variation in the medical assessment of CVD pilots. Countries use different tools and procedures for the testing of pilots, and also apply different result criteria to those tests. At one extreme an applicant making one error upon Ishihara 24-plate pseudoisochromatic plate (PIP) testing is declined a class 1 medical assessment, while at another extreme an applicant failing every color vision test required by the regulatory authority may be issued a medical assessment allowing commercial and airline copilot privileges. The medical assessment of CVD applicants is not performed consistently across the world. Factors that favor uniformity have been inadequate to encourage countries toward consistent medical assessment outcomes. This data is not consistent with the highest practicable degree of uniformity in medical assessment outcomes, and encourages aeromedical tourism.

  16. Method for uniformly bending conduits

    DOEpatents

    Dekanich, S.J.

    1984-04-27

    The present invention is directed to a method for bending metal tubing through various radii while maintaining uniform cross section of the tubing. The present invention is practical by filling the tubing to a sufficient level with water, freezing the water to ice and bending the ice-filled tubing in a cooled die to the desired radius. The use of the ice as a filler material provides uniform cross-sectional bends of the tubing and upon removal of the ice provides an uncontaminated interior of the tubing which will enable it to be used in its intended application without encountering residual contaminants in the tubing due to the presence of the filler material.

  17. Uniformed Services Former Spouses’ Protection Act

    DTIC Science & Technology

    2005-11-01

    Uniformed Services Former Spouses’ Protection Act Legal Assistance Branch Administrative and Civil Law ...1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law , no person shall be subject to a penalty...ADMINISTRATIVE & CIVIL LAW DEP’T, THE JUDGE ADVOCATE GENERAL’S LEGAL CENTER AND SCHOOL, U.S. ARMY, JA 274, Uniformed Services Former Spouses’ Protection

  18. Terrestrial carbon cycle affected by non-uniform climate warming

    NASA Astrophysics Data System (ADS)

    Xia, Jianyang; Chen, Jiquan; Piao, Shilong; Ciais, Philippe; Luo, Yiqi; Wan, Shiqiang

    2014-03-01

    Feedbacks between the terrestrial carbon cycle and climate change could affect many ecosystem functions and services, such as food production, carbon sequestration and climate regulation. The rate of climate warming varies on diurnal and seasonal timescales. A synthesis of global air temperature data reveals a greater rate of warming in winter than in summer in northern mid and high latitudes, and the inverse pattern in some tropical regions. The data also reveal a decline in the diurnal temperature range over 51% of the global land area and an increase over only 13%, because night-time temperatures in most locations have risen faster than daytime temperatures. Analyses of satellite data, model simulations and in situ observations suggest that the impact of seasonal warming varies between regions. For example, spring warming has largely stimulated ecosystem productivity at latitudes between 30° and 90° N, but suppressed productivity in other regions. Contrasting impacts of day- and night-time warming on plant carbon gain and loss are apparent in many regions. We argue that ascertaining the effects of non-uniform climate warming on terrestrial ecosystems is a key challenge in carbon cycle research.

  19. What drives sleep-dependent memory consolidation: greater gain or less loss?

    PubMed

    Fenn, Kimberly M; Hambrick, David Z

    2013-06-01

    When memory is tested after a delay, performance is typically better if the retention interval includes sleep. However, it is unclear what accounts for this well-established effect. It is possible that sleep enhances the retrieval of information, but it is also possible that sleep protects against memory loss that normally occurs during waking activity. We developed a new research approach to investigate these possibilities. Participants learned a list of paired-associate items and were tested on the items after a 12-h interval that included waking or sleep. We analyzed the number of items gained versus the number of items lost across time. The sleep condition showed more items gained and fewer items lost than did the wake condition. Furthermore, the difference between the conditions (favoring sleep) in lost items was greater than the difference in gain, suggesting that loss prevention may primarily account for the effect of sleep on declarative memory consolidation. This finding may serve as an empirical constraint on theories of memory consolidation.

  20. 24 CFR 5.705 - Uniform physical inspection requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Uniform physical inspection... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Physical Condition Standards and Inspection Requirements § 5.705 Uniform physical inspection requirements. Any entity responsible for...

  1. 24 CFR 5.705 - Uniform physical inspection requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Uniform physical inspection... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Physical Condition Standards and Inspection Requirements § 5.705 Uniform physical inspection requirements. Any entity responsible for...

  2. 24 CFR 5.705 - Uniform physical inspection requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Uniform physical inspection... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Physical Condition Standards and Inspection Requirements § 5.705 Uniform physical inspection requirements. Any entity responsible for...

  3. 24 CFR 5.705 - Uniform physical inspection requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Uniform physical inspection... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Physical Condition Standards and Inspection Requirements § 5.705 Uniform physical inspection requirements. Any entity responsible for...

  4. 24 CFR 5.705 - Uniform physical inspection requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Uniform physical inspection... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Physical Condition Standards and Inspection Requirements § 5.705 Uniform physical inspection requirements. Any entity responsible for...

  5. Uniform irradiation of irregularly shaped cavities for photodynamic therapy.

    PubMed

    Rem, A I; van Gemert, M J; van der Meulen, F W; Gijsbers, G H; Beek, J F

    1997-03-01

    It is difficult to achieve a uniform light distribution in irregularly shaped cavities. We have conducted a study on the use of hollow 'integrating' moulds for more uniform light delivery of photodynamic therapy in irregularly shaped cavities such as the oral cavity. Simple geometries such as a cubical box, a sphere, a cylinder and a 'bottle-neck' geometry have been investigated experimentally and the results have been compared with computed light distributions obtained using the 'radiosity method'. A high reflection coefficient of the mould and the best uniform direct irradiance possible on the inside of the mould were found to be important determinants for achieving a uniform light distribution.

  6. Automatic gain control in the echolocation system of dolphins

    NASA Astrophysics Data System (ADS)

    Au, Whitlow W. L.; Benoit-Bird, Kelly J.

    2003-06-01

    In bats and technological sonars, the gain of the receiver is progressively increased with time after the transmission of a signal to compensate for acoustic propagation loss. The current understanding of dolphin echolocation indicates that automatic gain control is not a part of their sonar system. In order to test this understanding, we have performed field measurements of free-ranging echolocating dolphins. Here we show that dolphins do possess an automatic gain control mechanism, but that it is implemented in the transmission phase rather than the receiving phase of a sonar cycle. We find that the amplitude of the dolphins' echolocation signals are highly range dependent; this amplitude increases with increasing target range, R, in a 20log(R) fashion to compensate for propagation loss. If the echolocation target is a fish school with many sound scatterers, the echoes from the school will remain nearly constant with range as the dolphin closes in on it. This characteristic has the same effect as time-varying gain in bats and technological sonar when considered from a sonar system perspective.

  7. Characteristics of Patients With Satisfactory Functional Gain Following Total Joint Arthroplasty in a Postacute Rehabilitation Setting.

    PubMed

    Hershkovitz, Avital; Vesilkov, Marina; Beloosesky, Yichayaou; Brill, Shai

    2017-01-10

    Total joint arthroplasty (TJA) is an effective and successful treatment of osteoarthritis of the hip and knee as quantified by several measures, such as pain relief, improved walking, improved self-care, functions, and increased quality of life. Data are lacking as to the definition of a satisfactory functional gain in a postacute setting and identifying the characteristics of older patients with TJA who may achieve that gain. Our aim was to characterize patients who may achieve a satisfactory functional gain in a postacute rehabilitation setting following TJA. This was a retrospective study of 180 patients with TJA admitted during 2010-2013. The main outcome measures were the Functional Independence Measure (FIM), the Montebello Rehabilitation Factor Score (MRFS) on the motor FIM, and the Timed Get Up and Go Test. Satisfactory functional gain was defined as an mFIM MRFS score above median score. Comparisons of clinical and demographic characteristics between patients who achieved a satisfactory functional gain versus those who did not were performed by the Mann-Whitney U test and the χ test. The proportion of patients who achieved a satisfactory functional gain was similar in the total knee arthroplasty and total hip arthroplasty (THA) groups. The most significant characteristic of patients who achieved a satisfactory functional gain was their admission functional ability. Age negatively impacted the ability to achieve a satisfactory functional gain in patients with THA. Functional level on admission is the best predictive factor for a better rehabilitation outcome for patients with TJA. Age negatively affects functional gain in patients with THA.

  8. Excessive weight gain during full breast-feeding.

    PubMed

    Grunewald, Maria; Hellmuth, Christian; Demmelmair, Hans; Koletzko, Berthold

    2014-01-01

    Breast-feeding is considered to offer optimal nutrition for healthy infant growth and development. Observational studies have linked breast-feeding to reduced obesity. CASE OBSERVATION: We observed an infant who was born macrosomic (4.56 kg) and showed excessive weight gain markedly exceeding the 97th percentile of weight during full breast-feeding. At the age of 4 months, the weight was greater than 11 kg. Clinical evaluation did not reveal any underlying pathology. After the introduction of complementary feeding and hence reduction of the breast milk intake, the excessive weight gain was attenuated and the slope of the percentile curve paralleled upper percentiles. Since this pattern suggested full breast-feeding as the driver of excessive weight gain, we analyzed the human milk composition at the infant age of 1 year and compared the results with published data on composition at this stage of lactation. The milk contents of lactose, fat, fatty acids, polar lipids, carnitine species, and insulin were similar to the reference data. The adiponectin content was increased. The most remarkable alteration was a high milk protein content (mean 1.25 g/dl, reference 0.8 g/dl). A very high protein supply in infancy has been previously shown to increase plasma concentrations of the growth factors insulin and IGF-1, weight gain, and later obesity. We speculate that interindividual variations in human milk adiponectin and protein contents may contribute to modulation of the growth of fully breast-fed infants and in this case may have contributed to excessive weight gain during full breast-feeding. This hypothesis merits being tested in future cohort studies. © 2014 S. Karger AG, Basel.

  9. Energy gain calculations in spherical IEC fusion systems using the BAFP code

    NASA Astrophysics Data System (ADS)

    Chacón, L.; Miley, G. H.; Barnes, D. C.; Knoll, D. A.

    1999-11-01

    The spherical IEC fusion concept takes advantage of the potential well generated by an inner spherical cathode (physical or virtual), biased negatively to several kV with respect to a concentric outer grounded boundary, to focus ions inwards and form a dense central core where fusion may occur. However, defocusing of the ion beams due to ion-ion collisions may prevent a satisfactory energy balance in the system. This research concentrates of spherically symmetric virtual cathode IEC devices, in which a spherical cloud of electrons, confined á la Penning trap, creates the ion-confining electrostatic well. A bounce-averaged Fokker-Planck model has been constructed to analyze the ion physics in ideal conditions (i.e., spherically uniform electrostatic well, no collisional interaction between ions and electrons, single ion species).(L. Chacon, D. C. Barnes, D. A. Knoll, 40^th) Annual Meeting of the APS Division of Plasma Physics, New Orleans, LA, Nov. 1998 Results will reproduce the phenomenology of previously published( W. Nevins, Phys. Plasmas), 2(10), 3804-3819 (1995) theoretical limits, and will show that, under some conditions, steady-state solutions with relatively high gains and small ion recirculation powers exist for the bounce-averaged Fokker-Planck transport equation. Variations in gain with parameter space will be presented.

  10. Fertigation uniformity under sprinkler irrigation: evaluation and analysis

    USDA-ARS?s Scientific Manuscript database

    n modern farming systems, fertigation is widely practiced as a cost effective and convenient method for applying soluble fertilizers to crops. Along with efficiency and adequacy, uniformity is an important fertigation performance evaluation criterion. Fertigation uniformity is defined here as a comp...

  11. Comparing gains and losses.

    PubMed

    McGraw, A Peter; Larsen, Jeff T; Kahneman, Daniel; Schkade, David

    2010-10-01

    Loss aversion in choice is commonly assumed to arise from the anticipation that losses have a greater effect on feelings than gains, but evidence for this assumption in research on judged feelings is mixed. We argue that loss aversion is present in judged feelings when people compare gains and losses and assess them on a common scale. But many situations in which people judge and express their feelings lack these features. When judging their feelings about an outcome, people naturally consider a context of similar outcomes for comparison (e.g., they consider losses against other losses). This process permits gains and losses to be normed separately and produces psychological scale units that may not be the same in size or meaning for gains and losses. Our experiments show loss aversion in judged feelings for tasks that encourage gain-loss comparisons, but not tasks that discourage them, particularly those using bipolar scales.

  12. Uniform color space is not homogeneous

    NASA Astrophysics Data System (ADS)

    Kuehni, Rolf G.

    2002-06-01

    Historical data of chroma scaling and hue scaling are compared and evidence is shown that we do not have a reliable basis in either case. Several data sets indicate explicitly or implicitly that the number of constant sized hue differences between unique hues as well as in the quadrants of the a*, b* diagram differs making what is commonly regarded as uniform color space inhomogeneous. This problem is also shown to affect the OSA-UCS space. A Euclidean uniform psychological or psychophysical color space appears to be impossible.

  13. Thermal protective uniforms and hoods: impact of design modifications and water content on burn prevention in New York City firefighters: laboratory and field results

    PubMed Central

    Prezant, D; Malley, K; Barker, R; Guerth, C; Kelly, K

    2001-01-01

    Objectives—To determine (1) the effectiveness of hoods in reducing head burns, (2) the impact of clothes worn under the protective outer uniform (modern = long sleeve shirt and long pants; modified modern = short sleeve T-shirt and short pants) on burns, and (3) whether water content (dry, damp or saturated) affects the level of thermal protection. Setting—Fire Department of the City of New York (FDNY). Methods—Laboratory tests (fully dressed manikin) evaluated the different uniform and water conditions when exposed to an average 24 cal/cm2 heat flux, approximately 2250°F air temperature. FDNY field results compared (1) head burns during winters wearing the hood to winters without hood and (2) upper and lower extremity burns during summers wearing traditional, modern, and modified modern uniforms. Results—Laboratory tests showed that thermal protection was: (1) dramatically improved by the hood with protection increasing as water content increased and (2) not significantly different between modern and modified modern uniforms, regardless of water content. FDNY field results confirmed these tests showing (1) significant decreases in neck burns (by 54%), ear burns (by 60%), and head burn totals (by 46%) wearing the hood and (2) no significant differences in upper or lower extremity burns wearing modern compared with modified modern uniforms. Conclusions—Based on combined laboratory and field results, we strongly recommend the use of modern thermal protective hoods and the modified modern uniform. PMID:11565971

  14. Pressure-induced structural change in liquid GaIn eutectic alloy.

    PubMed

    Yu, Q; Ahmad, A S; Ståhl, K; Wang, X D; Su, Y; Glazyrin, K; Liermann, H P; Franz, H; Cao, Q P; Zhang, D X; Jiang, J Z

    2017-04-25

    Synchrotron x-ray diffraction reveals a pressure induced crystallization at about 3.4 GPa and a polymorphic transition near 10.3 GPa when compressed a liquid GaIn eutectic alloy up to ~13 GPa at room temperature in a diamond anvil cell. Upon decompression, the high pressure crystalline phase remains almost unchanged until it transforms to the liquid state at around 2.3 GPa. The ab initio molecular dynamics calculations can reproduce the low pressure crystallization and give some hints on the understanding of the transition between the liquid and the crystalline phase on the atomic level. The calculated pair correlation function g(r) shows a non-uniform contraction reflected by the different compressibility between the short (1st shell) and the intermediate (2nd to 4th shells). It is concluded that the pressure-induced liquid-crystalline phase transformation likely arises from the changes in local atomic packing of the nearest neighbors as well as electronic structures at the transition pressure.

  15. 7 CFR 1776.2 - Uniform Federal Assistance Provisions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Uniform Federal Assistance Provisions. 1776.2 Section 1776.2 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE (CONTINUED) HOUSEHOLD WATER WELL SYSTEM GRANT PROGRAM General § 1776.2 Uniform...

  16. 7 CFR 1776.2 - Uniform Federal Assistance Provisions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 12 2011-01-01 2011-01-01 false Uniform Federal Assistance Provisions. 1776.2 Section 1776.2 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE (CONTINUED) HOUSEHOLD WATER WELL SYSTEM GRANT PROGRAM General § 1776.2 Uniform...

  17. 7 CFR 1776.2 - Uniform Federal Assistance Provisions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 12 2013-01-01 2013-01-01 false Uniform Federal Assistance Provisions. 1776.2 Section 1776.2 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE (CONTINUED) HOUSEHOLD WATER WELL SYSTEM GRANT PROGRAM General § 1776.2 Uniform...

  18. 7 CFR 1776.2 - Uniform Federal Assistance Provisions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 12 2014-01-01 2013-01-01 true Uniform Federal Assistance Provisions. 1776.2 Section 1776.2 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE (CONTINUED) HOUSEHOLD WATER WELL SYSTEM GRANT PROGRAM General § 1776.2 Uniform...

  19. 7 CFR 1776.2 - Uniform Federal Assistance Provisions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 12 2012-01-01 2012-01-01 false Uniform Federal Assistance Provisions. 1776.2 Section 1776.2 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE (CONTINUED) HOUSEHOLD WATER WELL SYSTEM GRANT PROGRAM General § 1776.2 Uniform...

  20. Design and evaluation of an imaging spectrophotometer incorporating a uniform light source.

    PubMed

    Noble, S D; Brown, R B; Crowe, T G

    2012-03-01

    Accounting for light that is diffusely scattered from a surface is one of the practical challenges in reflectance measurement. Integrating spheres are commonly used for this purpose in point measurements of reflectance and transmittance. This solution is not directly applicable to a spectral imaging application for which diffuse reflectance measurements are desired. In this paper, an imaging spectrophotometer design is presented that employs a uniform light source to provide diffuse illumination. This creates the inverse measurement geometry to the directional illumination/diffuse reflectance mode typically used for point measurements. The final system had a spectral range between 400 and 1000 nm with a 5.2 nm resolution, a field of view of approximately 0.5 m by 0.5 m, and millimeter spatial resolution. Testing results indicate illumination uniformity typically exceeding 95% and reflectance precision better than 1.7%.

  1. Uniform Federal Accessibility Standards.

    ERIC Educational Resources Information Center

    Department of Housing and Urban Development, Washington, DC.

    The document presents uniform standards for facility accessibility by physically handicapped persons for Federal and federally funded facilities. The standards are to be applied during the design, construction, and alteration of buildings and facilities to the extent required by the Architectural Barriers Act of 1968, as amended. Technical…

  2. A Pilot Study for Gainful Employment in Home Economics. Final Report. Volume I.

    ERIC Educational Resources Information Center

    Cozine, June; And Others

    The major purpose of the study was to develop and test curriculum materials for three entry level gainful employment courses: Child Care Services, Clothing Services, Food Services. A second objective was to formulate recommendations for policies and procedures to follow in initiating and developing gainful employment programs in home economics.…

  3. Vertical uniformity of cells and nuclei in epithelial monolayers.

    PubMed

    Neelam, Srujana; Hayes, Peter Robert; Zhang, Qiao; Dickinson, Richard B; Lele, Tanmay P

    2016-01-22

    Morphological variability in cytoskeletal organization, organelle position and cell boundaries is a common feature of cultured cells. Remarkable uniformity and reproducibility in structure can be accomplished by providing cells with defined geometric cues. Cells in tissues can also self-organize in the absence of directing extracellular cues; however the mechanical principles for such self-organization are not understood. We report that unlike horizontal shapes, the vertical shapes of the cell and nucleus in the z-dimension are uniform in cells in cultured monolayers compared to isolated cells. Apical surfaces of cells and their nuclei in monolayers were flat and heights were uniform. In contrast, isolated cells, or cells with disrupted cell-cell adhesions had nuclei with curved apical surfaces and variable heights. Isolated cells cultured within micron-sized square wells displayed flat cell and nuclear shapes similar to cells in monolayers. Local disruption of nuclear-cytoskeletal linkages resulted in spatial variation in vertical uniformity. These results suggest that competition between cell-cell pulling forces that expand and shorten the vertical cell cross-section, thereby widening and flattening the nucleus, and the resistance of the nucleus to further flattening results in uniform cell and nuclear cross-sections. Our results reveal the mechanical principles of self-organized vertical uniformity in cell monolayers.

  4. Normal uniform mixture differential gene expression detection for cDNA microarrays

    PubMed Central

    Dean, Nema; Raftery, Adrian E

    2005-01-01

    Background One of the primary tasks in analysing gene expression data is finding genes that are differentially expressed in different samples. Multiple testing issues due to the thousands of tests run make some of the more popular methods for doing this problematic. Results We propose a simple method, Normal Uniform Differential Gene Expression (NUDGE) detection for finding differentially expressed genes in cDNA microarrays. The method uses a simple univariate normal-uniform mixture model, in combination with new normalization methods for spread as well as mean that extend the lowess normalization of Dudoit, Yang, Callow and Speed (2002) [1]. It takes account of multiple testing, and gives probabilities of differential expression as part of its output. It can be applied to either single-slide or replicated experiments, and it is very fast. Three datasets are analyzed using NUDGE, and the results are compared to those given by other popular methods: unadjusted and Bonferroni-adjusted t tests, Significance Analysis of Microarrays (SAM), and Empirical Bayes for microarrays (EBarrays) with both Gamma-Gamma and Lognormal-Normal models. Conclusion The method gives a high probability of differential expression to genes known/suspected a priori to be differentially expressed and a low probability to the others. In terms of known false positives and false negatives, the method outperforms all multiple-replicate methods except for the Gamma-Gamma EBarrays method to which it offers comparable results with the added advantages of greater simplicity, speed, fewer assumptions and applicability to the single replicate case. An R package called nudge to implement the methods in this paper will be made available soon at . PMID:16011807

  5. Active rc filter permits easy trade-off of amplifier gain and sensitivity to gain

    NASA Technical Reports Server (NTRS)

    Kerwin, W. J.; Shaffer, C. V.

    1968-01-01

    Passive RC network was designed with zeros of transmission in the right half of the complex frequency plane in the feedback loop of a simple negative-gain amplifier. The proper positioning provides any desired trade-off between amplifier gain and sensitivity to amplifier gain.

  6. Nurse uniform wearing practices and associated factors among nurses working in Northwest Ethiopia: a cross-sectional institution based study.

    PubMed

    Desta, Etaferahu Alamaw; Gebrie, Mignote Hailu; Dachew, Berihun Assefa

    2015-01-01

    Wearing uniforms help in the formation of professional identity in healthcare. It fosters a strong self image and professional identity which can lead to good confidence and better performance in nursing practice. However, most nurses in Ethiopia are not wearing nursing uniforms and the reasons remain unclear. Therefore, the aim of this research is to assess nurse uniform wearing practices among nurses and factors associated with such practice in hospitals in Northwest Ethiopia. A hospital based cross-sectional study was conducted from March to April, 2014 in five hospitals located in Northwest Ethiopia. A total 459 nurses participated in the study. Data was collected using a pre-tested self-administered questionnaire. Descriptive statistics were analyzed in order to characterize the study population. Bivariate and multiple logistic regression models were fitted. Odds ratios with 95 % confidence intervals were computed to identify factors associated with nursing uniform practice. Nurse uniform wearing practice was found to be 49.2 % of the total sample size. Around 35 % of the respondents that did not implement nurse uniform wearing practices stated that there was no specific uniform for nurses recommended by hospital management. In addition to this, nurse uniform wearing practices were positively associated with being female [AOR = 1.58, 95 % CI (1.02, 2.44)], studying nursing by choice [AOR =3.16, 95 % CI (2.03, 4.92)], and the appeal of nursing uniforms to nurses [AOR = 3.43 95 % CI (1.96, 5.98)]. Nurse uniform wearing practices were not exceptionally prevalent in Northwest Ethiopian hospitals. However, encouraging students to pursue interest-based careers and implementing a nurse uniform wearing policy may have the potential to improve such practices.

  7. Beam uniformity of flat top lasers

    NASA Astrophysics Data System (ADS)

    Chang, Chao; Cramer, Larry; Danielson, Don; Norby, James

    2015-03-01

    Many beams that output from standard commercial lasers are multi-mode, with each mode having a different shape and width. They show an overall non-homogeneous energy distribution across the spot size. There may be satellite structures, halos and other deviations from beam uniformity. However, many scientific, industrial and medical applications require flat top spatial energy distribution, high uniformity in the plateau region, and complete absence of hot spots. Reliable standard methods for the evaluation of beam quality are of great importance. Standard methods are required for correct characterization of the laser for its intended application and for tight quality control in laser manufacturing. The International Organization for Standardization (ISO) has published standard procedures and definitions for this purpose. These procedures have not been widely adopted by commercial laser manufacturers. This is due to the fact that they are unreliable because an unrepresentative single-pixel value can seriously distort the result. We hereby propose a metric of beam uniformity, a way of beam profile visualization, procedures to automatically detect hot spots and beam structures, and application examples in our high energy laser production.

  8. Uniform emergency codes: will they improve safety?

    PubMed

    2005-01-01

    There are pros and cons to uniform code systems, according to emergency medicine experts. Uniformity can be a benefit when ED nurses and other staff work at several facilities. It's critical that your staff understand not only what the codes stand for, but what they must do when codes are called. If your state institutes a new system, be sure to hold regular drills to familiarize your ED staff.

  9. A Temperature-Based Gain Calibration Technique for Precision Radiometry

    NASA Astrophysics Data System (ADS)

    Parashare, Chaitali Ravindra

    temperature which varies significantly with different climatic conditions. The model used to correct for gain variations is presented. We describe the measurements performed to verify the model. RFI is a major issue at low frequencies, which makes these kind of measurements extremely challenging. We discuss the careful measures required to mitigate the errors due to the unwanted interference. In the case of the laboratory measurements, the model follows closely with the measured power, and shows an improvement in the gain stability by a factor of ˜ 46, when the corrections are applied. The gain stability (rms to mean) improves from 1 part in 32 to 1 part in 1500. The field measurements suggest that correcting for cable temperature variations is challenging. The improvement in the gain stability is by a factor of ˜ 4.3, when the RF front end components are situated out in the field. The results are analyzed using the statistical methods such as the standard error of the mean, the run test, skewness, and kurtosis. These tests demonstrate the normal distribution of the process when the corrections are applied and confirm an effective gain bias removal. The results obtained from the sky observation using a single antenna element are compared before and after applying the corrections. Several days data verify that the power fluctuations are significantly reduced after the gain corrections are applied.

  10. Improved Gain Microstrip Patch Antenna

    DTIC Science & Technology

    2015-08-06

    08-2015 Publication Improved Gain Microstrip Patch Antenna David A. Tonn Naval Under Warfare Center Division, Newport 1176 Howell St., Code 00L...GAIN MICROSTRIP PATCH ANTENNA STATEMENT OF GOVERNMENT INTEREST [0001] The invention described herein may be manufactured and used by or for the...patch antenna having increased gain, and an apparatus for increasing the gain and bandwidth of an existing microstrip patch antenna . (2) Description

  11. Combined Heat and Power Protocol for Uniform Methods Project | Advanced

    Science.gov Websites

    Manufacturing Research | NREL Combined Heat and Power Protocol for Uniform Methods Project Combined Heat and Power Protocol for Uniform Methods Project NREL developed a protocol that provides a ; is consistent with the scope and other protocols developed for the Uniform Methods Project (UMP

  12. 25 CFR 23.49 - Fair and uniform provision of services.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Fair and uniform provision of services. 23.49 Section 23.49 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES INDIAN CHILD WELFARE ACT General and Uniform Grant Administration Provisions and Requirements § 23.49 Fair and uniform...

  13. Cooking increases net energy gain from a lipid-rich food.

    PubMed

    Groopman, Emily E; Carmody, Rachel N; Wrangham, Richard W

    2015-01-01

    Starch, protein, and lipid are three major sources of calories in the human diet. The unique and universal human practice of cooking has been demonstrated to increase the energy gained from foods rich in starch or protein. Yet no studies have tested whether cooking has equivalent effects on the energy gained from lipid-rich foods. Using mice as a model, we addressed this question by examining the impact of cooking on the energy gained from peanuts, a lipid-rich oilseed, and compared this impact against that of nonthermal processing (blending). We found that cooking consistently increased the energy gained per calorie, whereas blending had no detectable energetic benefits. Assessment of fecal fat excretion showed increases in lipid digestibility when peanuts were cooked, and examination of diet microstructure revealed concomitant alterations to the integrity of cell walls and the oleosin layer of proteins that otherwise shield lipids from digestive lipases. Both effects were consistent with the greater energy gain observed with cooking. Our findings highlight the importance of cooking in increasing dietary energy returns for humans, both past and present. © 2014 Wiley Periodicals, Inc.

  14. Mass test of AdvanSiD model ASD-NUV3S-P SiliconPMs for the Pixel Timing Counter of the MEG II experiment

    NASA Astrophysics Data System (ADS)

    Rossella, M.; Bariani, S.; Barnaba, O.; Cattaneo, P. W.; Cervi, T.; Menegolli, A.; Nardò, R.; Prata, M. C.; Romano, E.; Scagliotti, C.; Simonetta, M.; Vercellati, F.

    2017-02-01

    The MEG II Timing Counter will measure the positron time of arrival with a resolution of 30 ps relying on two arrays of scintillator pixels read out by 6144 Silicon Photomultipliers (SiPMs) from AdvanSiD. They must be characterized, measuring their breakdown voltage, to assure that the gains of the SiPMs of each pixel are as uniform as possible, to maximize the pixel resolution. To do this an automatic test system that can measure sequentially the parameters of 32 devices has been developed.

  15. 7 CFR 51.1407 - Fairly uniform in color.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Fairly uniform in color. 51.1407 Section 51.1407 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... in color. Fairly uniform in color means that the shells do not show sufficient variation in color to...

  16. 7 CFR 51.1407 - Fairly uniform in color.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Fairly uniform in color. 51.1407 Section 51.1407 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... in color. Fairly uniform in color means that the shells do not show sufficient variation in color to...

  17. 7 CFR 51.1447 - Fairly uniform in color.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... color. Fairly uniform in color means that 90 percent or more of the kernels in the lot have skin color within the range of one or two color classifications. ... 7 Agriculture 2 2011-01-01 2011-01-01 false Fairly uniform in color. 51.1447 Section 51.1447...

  18. 7 CFR 51.1447 - Fairly uniform in color.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... color. Fairly uniform in color means that 90 percent or more of the kernels in the lot have skin color within the range of one or two color classifications. ... 7 Agriculture 2 2012-01-01 2012-01-01 false Fairly uniform in color. 51.1447 Section 51.1447...

  19. 7 CFR 51.1407 - Fairly uniform in color.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Fairly uniform in color. 51.1407 Section 51.1407 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... in color. Fairly uniform in color means that the shells do not show sufficient variation in color to...

  20. 7 CFR 51.1447 - Fairly uniform in color.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Fairly uniform in color. 51.1447 Section 51.1447... color. Fairly uniform in color means that 90 percent or more of the kernels in the lot have skin color within the range of one or two color classifications. ...

  1. Modeling of the gain distribution for diode pumping of a solid-state laser rod with nonimaging optics.

    PubMed

    Koshel, R J; Walmsley, I A

    1993-03-20

    We investigate the absorption distribution in a cylindrical gain medium that is pumped by a source of distributed laser diodes by means of a pump cavity developed from the edge-ray principle of nonimaging optics. The performance of this pumping arrangement is studied by using a nonsequential, numerical, three-dimensional ray-tracing scheme. A figure of merit is defined for the pump cavities that takes into account the coupling efficiency and uniformity of the absorption distribution. It is found that the nonimaging pump cavity maintains a high coupling efficiency with extended two-dimensional diode arrays and obtains a fairly uniform absorption distribution. The nonimaging cavity is compared with two other designs: a close-coupled side-pumped cavity and an imaging design in the form of a elliptical cavity. The nonimaging cavity has a better figure of merit per diode than these two designs. It also permits the use of an extended, sparse, two-dimensional diode array, which reduces thermal loading of the source and eliminates all cavity optics other than the main reflector.

  2. Information Gain Based Dimensionality Selection for Classifying Text Documents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dumidu Wijayasekara; Milos Manic; Miles McQueen

    2013-06-01

    Selecting the optimal dimensions for various knowledge extraction applications is an essential component of data mining. Dimensionality selection techniques are utilized in classification applications to increase the classification accuracy and reduce the computational complexity. In text classification, where the dimensionality of the dataset is extremely high, dimensionality selection is even more important. This paper presents a novel, genetic algorithm based methodology, for dimensionality selection in text mining applications that utilizes information gain. The presented methodology uses information gain of each dimension to change the mutation probability of chromosomes dynamically. Since the information gain is calculated a priori, the computational complexitymore » is not affected. The presented method was tested on a specific text classification problem and compared with conventional genetic algorithm based dimensionality selection. The results show an improvement of 3% in the true positives and 1.6% in the true negatives over conventional dimensionality selection methods.« less

  3. Influence of travel speed on spray deposition uniformity from an air-assisted variable-rate sprayer

    USDA-ARS?s Scientific Manuscript database

    A newly developed LiDAR-guided air-assisted variable-rate sprayer for nursery and orchard applications was tested at various travel speeds to compare its spray deposition and coverage uniformity with constant-rate applications. Spray samplers, including nylon screens and water-sensitive papers (WSP)...

  4. Dynamic measurements in non-uniform flows

    NASA Astrophysics Data System (ADS)

    Ershov, A. P.

    2017-12-01

    The response of gauges registering the flow velocity and pressure in highly non-uniform media (for example, a powder under shock compression or powdered low-density explosive) is simulated. The modeling employs an acoustic approach. Against the average level of the signal, the fluctuations generated by the heterogeneity of the medium are observed which may distort the results completely. For reliable measurements, gauges larger than the characteristic scale of the medium non-uniformity are required. Under this condition, electromagnetic flow measurements and the velocity interferometer system for any reflector (VISAR) produce quite similar flow velocity profiles with small level of noise.

  5. Dynamic measurements in non-uniform flows

    NASA Astrophysics Data System (ADS)

    Ershov, A. P.

    2018-07-01

    The response of gauges registering the flow velocity and pressure in highly non-uniform media (for example, a powder under shock compression or powdered low-density explosive) is simulated. The modeling employs an acoustic approach. Against the average level of the signal, the fluctuations generated by the heterogeneity of the medium are observed which may distort the results completely. For reliable measurements, gauges larger than the characteristic scale of the medium non-uniformity are required. Under this condition, electromagnetic flow measurements and the velocity interferometer system for any reflector (VISAR) produce quite similar flow velocity profiles with small level of noise.

  6. Experimental and Numerical Characterization of a Pulsed Supersonic Uniform Flow for Kinetics and Spectroscopy

    NASA Astrophysics Data System (ADS)

    Suas-David, Nicolas; Thawoos, Shameemah; Broderick, Bernadette M.; Suits, Arthur

    2017-06-01

    The current CPUF (Chirped Pulse Uniform Flow) and the new UF-CRDS (Uniform Flow Cavity Ring-Down Spectroscopy) setups relie mostly on the production of a good quality supersonic uniform flow. A supersonic uniform flow is produced by expanding a gas through a Laval nozzle - similar to the nozzles used in aeronautics - linked to a vacuum chamber. The expansion is characterized by an isentropic core where constant very low kinetic temperature (down to 20K) and constant density are observed. The relatively large diameter of the isentropic core associated with homogeneous thermodynamic conditions makes it a relevant tool for low temperature spectroscopy. On the other hand, the length along the axis of the flow of this core (could be longer than 50cm) allows kinetic studies which is one of the main interest of this setup (CRESU technique. The formation of a uniform flow requires an extreme accuracy in the design of the shape of the nozzle for a set of defined temperature/density. The design is based on a Matlab program which retrieves the shape of the isentropic core according to the method of characteristics prior to calculate the thickness of the boundary layer. Two different approaches are used to test the viability of a new nozzle derived from the program. First, a computational fluid dynamic software (OpenFOAM) models the distribution of the thermodynamic properties of the expansion. Then, fabricated nozzles using 3-D printing are tested based on Pitot measurements and spectroscopic analyses. I will present comparisons of simulation and measured performance for a range of nozzles. We will see how the high level of accuracy of numerical simulations provides a deeper knowledge of the experimental conditions. J. M. Oldham, C. Abeysekera, J. Joalland, L. N. Zack, K. Prozument, I. R. Sims, G. Barrat Park, R. W. Filed and A. G. Suits, J. Chem. Phys. 141, 154202, (2014). I. Sims, J. L. Queffelec, A. Defrance, C. Rebrion-Rowe, D. Travers, P. Bocherel, B. Rowe, I. W. Smith

  7. Commutated automatic gain control system

    NASA Technical Reports Server (NTRS)

    Yost, S. R.

    1982-01-01

    The commutated automatic gain control (AGC) system was designed and built for the prototype Loran-C receiver is discussed. The current version of the prototype receiver, the Mini L-80, was tested initially in 1980. The receiver uses a super jolt microcomputer to control a memory aided phase loop (MAPLL). The microcomputer also controls the input/output, latitude/longitude conversion, and the recently added AGC system. The AGC control adjusts the level of each station signal, such that the early portion of each envelope rise is about at the same amplitude in the receiver envelope detector.

  8. Commutated automatic gain control system

    NASA Technical Reports Server (NTRS)

    Yost, S. R.

    1982-01-01

    A commutated automatic gain control (AGC) system was designed and built for a prototype Loran C receiver. The receiver uses a microcomputer to control a memory aided phase-locked loop (MAPLL). The microcomputer also controls the input/output, latitude/longitude conversion, and the recently added AGC system. The circuit designed for the AGC is described, and bench and flight test results are presented. The AGC circuit described actually samples starting at a point 40 microseconds after a zero crossing determined by the software lock pulse ultimately generated by a 30 microsecond delay and add network in the receiver front end envelope detector.

  9. Below-threshold harmonic generation from strong non-uniform fields

    NASA Astrophysics Data System (ADS)

    Yavuz, I.

    2017-10-01

    Strong-field photoemission below the ionization threshold is a rich/complex region where atomic emission and harmonic generation may coexist. We studied the mechanism of below-threshold harmonics (BTH) from spatially non-uniform local fields near the metallic nanostructures. Discrete harmonics are generated due to the broken inversion symmetry, suggesting enriched coherent emission in the vuv frequency range. Through the numerical solution of the time-dependent Schrödinger equation, we investigate wavelength and intensity dependence of BTH. Wavelength dependence identifies counter-regular resonances; individual contributions from the multi-photon emission and channel-closing effects due to quantum path interferences. In order to understand the underlying mechanism of BTH, we devised a generalized semi-classical model, including the influence of Coulomb and non-uniform field interactions. As in uniform fields, Coulomb potential in non-uniform fields is the determinant of BTH; we observed that the generation of BTH are due to returning trajectories with negative energies. Due to large distance effectiveness of the non-uniformity, only long trajectories are noticeably affected.

  10. The impact of recombination on short-term selection gain in plant breeding experiments.

    PubMed

    McClosky, Benjamin; Tanksley, Steven D

    2013-09-01

    Recombination is a requirement for response to selection, but researchers still debate whether increasing recombination beyond normal levels will result in significant gains in short-term selection. We tested this hypothesis, in the context of plant breeding, through a series of simulation experiments comparing short-term selection response (≤20 cycles) between populations with normal levels of recombination and similar populations with unconstrained recombination (i.e., free recombination). We considered additive and epistatic models and examined a wide range of values for key design variables: selection cycles, QTL number, heritability, linkage phase, selection intensity and population size. With few exceptions, going from normal to unconstrained levels of recombination produced only modest gains in response to selection (≈11 % on average). We then asked how breeders might capture some of this theoretical gain by increasing recombination through either (1) extra rounds of mating or (2) selection of highly recombinant individuals via use of molecular markers/maps. All methods tested captured less than half of the potential gain, but our analysis indicates that the most effective method is to select for increased recombination and the trait simultaneously. This recommendation is based on evidence of a favorable interaction between trait selection and the impact of recombination on selection gains. Finally, we examined the relative contributions of the two components of meiotic recombination, chromosome assortment and crossing over, to short-term selection gain. Depending primarily on the presence of trait selection pressure, chromosome assortment alone accounted for 40-75 % of gain in response to short-term selection.

  11. Enhancement of a 2D front-tracking algorithm with a non-uniform distribution of Lagrangian markers

    NASA Astrophysics Data System (ADS)

    Febres, Mijail; Legendre, Dominique

    2018-04-01

    The 2D front tracking method is enhanced to control the development of spurious velocities for non-uniform distributions of markers. The hybrid formulation of Shin et al. (2005) [7] is considered. A new tangent calculation is proposed for the calculation of the tension force at markers. A new reconstruction method is also proposed to manage non-uniform distributions of markers. We show that for both the static and the translating spherical drop test case the spurious currents are reduced to the machine precision. We also show that the ratio of the Lagrangian grid size Δs over the Eulerian grid size Δx has to satisfy Δs / Δx > 0.2 for ensuring such low level of spurious velocity. The method is found to provide very good agreement with benchmark test cases from the literature.

  12. Measurement of luminance and color uniformity of displays using the large-format scanner

    NASA Astrophysics Data System (ADS)

    Mazikowski, Adam

    2017-08-01

    Uniformity of display luminance and color is important for comfort and good perception of the information presented on the display. Although display technology has developed and improved a lot over the past years, different types of displays still present a challenge in selected applications, e.g. in medical use or in case of multi-screen installations. A simplified 9-point method of determining uniformity does not always produce satisfactory results, so a different solution is proposed in the paper. The developed system consists of the large-format X-Y-Z ISEL scanner (isel Germany AG), Konica Minolta high sensitivity spot photometer-colorimeter (e.g. CS-200, Konica Minolta, Inc.) and PC computer. Dedicated software in LabView environment for control of the scanner, transfer the measured data to the computer, and visualization of measurement results was also prepared. Based on the developed setup measurements of plasma display and LCD-LED display were performed. A heavily wornout plasma TV unit, with several artifacts visible was selected. These tests show the advantages and drawbacks of described scanning method with comparison with 9-point simplified uniformity determining method.

  13. Uniform, stable supply of medium for in vitro cell culture using a robust chamber

    NASA Astrophysics Data System (ADS)

    Wei, Juan; Liu, Chong; Jiang, Yang; Liu, Tao; Chen, Li; Liu, Bo; Li, Jingmin

    2018-06-01

    A uniform, stable supply of medium is important for in vitro cell culture. In this paper, a microfluidic device is presented for culturing cells inside a robust chamber with continuous perfusion of medium. The device consists of a main channel, two bifurcated channels and a culture chamber. The culture chamber connects to the bifurcated channels via multiple paths, and distributes symmetrically on the main channel, to improve the efficiency of medium exchange. Furthermore, regular polygonal chambers with various numbers of edges have been designed, to study the effects of chamber shape on flow fields. The finite element method has been employed to predict the effects of multiple paths on the uniformity and stability of flow fields in the culture chamber. Particle tracking technology has been used to evaluate the flow fields in the chambers, and PC-12 cells have been cultured using the microfluidic device, to test its validity. The results of simulation and experiment indicate that the microfluidic design could provide a continuous interstitial-like flow microenvironment, with a relatively stable and uniform supply of medium.

  14. Heat Balance Limits in Football Uniforms: How Different Uniform Ensembles Alter the Equation.

    ERIC Educational Resources Information Center

    Kulka, Hasha J.; Kenney, W. Larry

    2002-01-01

    Because football season becomes dangerous when warm weather collides with the need for protective gear, researchers investigated critical heat balance limits in non-heat- acclimatized men who wore various football uniform ensembles and exercised at 35 percent VO2 max in a programmable environmental chamber. The air temperature and humidity limits…

  15. Reactor for making uniform capsules

    NASA Technical Reports Server (NTRS)

    Wang, Taylor G. (Inventor); Anikumar, Amrutur V. (Inventor); Lacik, Igor (Inventor)

    1999-01-01

    The present invention provides a novel reactor for making capsules with uniform membrane. The reactor includes a source for providing a continuous flow of a first liquid through the reactor; a source for delivering a steady stream of drops of a second liquid to the entrance of the reactor; a main tube portion having at least one loop, and an exit opening, where the exit opening is at a height substantially equal to the entrance. In addition, a method for using the novel reactor is provided. This method involves providing a continuous stream of a first liquid; introducing uniformly-sized drops of the second liquid into the stream of the first liquid; allowing the drops to react in the stream for a pre-determined period of time; and collecting the capsules.

  16. 46 CFR 403.400 - Uniform pilot's source form.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 8 2011-10-01 2011-10-01 false Uniform pilot's source form. 403.400 Section 403.400... ACCOUNTING SYSTEM Source Forms § 403.400 Uniform pilot's source form. (a) Each Association shall record pilotage transactions on a form approved by the Director. The approved form shall be issued to pilots by...

  17. Prototype development and demonstration for response, emergency staging, communications, uniform management, and evacuation (R.E.S.C.U.M.E.) : technical report on prototype development and field testing of R.E.S.C.U.M.E. applications.

    DOT National Transportation Integrated Search

    2015-04-01

    This document is the final project technical report for the development and field testing of the Response, Emergency Staging, Communications, Uniform Management, and Evacuation (R.E.S.C.U.M.E.) application bundle, with a focus on the Incident Zone (I...

  18. Measurement Uncertainty Within the Uniform Engine Test Programme

    DTIC Science & Technology

    1989-05-01

    Design to Cost and l.ifc (.cle Cost to Aircraft Engines AGARD LS 107 (May 1980) Microcomputer Applications in Power and Propulsion Systems AGARD LS...Flows in Propulsion Systems AGARD LS 140 (June 1985) Engine Airframe Integration for Rotorcraft AGARD LS 148 (June 1986) Design Methods Used in Solid...modest nero-thermodynamic design was of no consequence. Two engines were loaned to the proeram by the U.S. Air Force. Due to higher priority test workload

  19. Designing divertor targets for uniform power load

    NASA Astrophysics Data System (ADS)

    Dekeyser, W.; Reiter, D.; Baelmans, M.

    2015-08-01

    Divertor design for next step fusion reactors heavily relies on 2D edge plasma modeling with codes as e.g. B2-EIRENE. While these codes are typically used in a design-by-analysis approach, in previous work we have shown that divertor design can alternatively be posed as a mathematical optimization problem, and solved very efficiently using adjoint methods adapted from computational aerodynamics. This approach has been applied successfully to divertor target shape design for more uniform power load. In this paper, the concept is further extended to include all contributions to the target power load, with particular focus on radiation. In a simplified test problem, we show the potential benefits of fully including the radiation load in the design cycle as compared to only assessing this load in a post-processing step.

  20. A Comparison of Uniform DIF Effect Size Estimators under the MIMIC and Rasch Models

    ERIC Educational Resources Information Center

    Jin, Ying; Myers, Nicholas D.; Ahn, Soyeon; Penfield, Randall D.

    2013-01-01

    The Rasch model, a member of a larger group of models within item response theory, is widely used in empirical studies. Detection of uniform differential item functioning (DIF) within the Rasch model typically employs null hypothesis testing with a concomitant consideration of effect size (e.g., signed area [SA]). Parametric equivalence between…

  1. VOR Gain Is Related to Compensatory Saccades in Healthy Older Adults

    PubMed Central

    Anson, Eric R.; Bigelow, Robin T.; Carey, John P.; Xue, Qian-Li; Studenski, Stephanie; Schubert, Michael C.; Agrawal, Yuri

    2016-01-01

    Objective: Vestibulo-ocular reflex (VOR) gain is well-suited for identifying rotational vestibular dysfunction, but may miss partial progressive decline in age-related vestibular function. Since compensatory saccades might provide an alternative method for identifying subtle vestibular decline, we describe the relationship between VOR gain and compensatory saccades in healthy older adults. Methods: Horizontal VOR gain was measured in 243 subjects age 60 and older from the Baltimore Longitudinal Study of Aging using video head impulse testing (HIT). Saccades in each HIT were identified as either “compensatory” or “compensatory back-up,” i.e., same or opposite direction as the VOR response respectively. Saccades were also classified as “covert” (occurring during head movement) and “overt” (occurring after head movement). The relationship between VOR gain and percentage of HITs with saccades, as well as the relationship between VOR gain and saccade latency and amplitude, were evaluated using regression analyses adjusting for age, gender, and race. Results: In adjusted analyses, the percentage of HITs with compensatory saccades increased 4.5% for every 0.1 decrease in VOR gain (p < 0.0001). Overt compensatory saccade amplitude decreased 0.6° (p < 0.005) and latency increased 90 ms (p < 0.001) for every 0.1 increase in VOR gain. Covert back-up compensatory saccade amplitude increased 0.4° for every 0.1 increase in VOR gain. Conclusion: We observed significant relationships between VOR gain and compensatory saccades in healthy older adults. Lower VOR gain was associated with larger amplitude, shorter latency compensatory saccades. Compensatory saccades reflect underlying rotational vestibular hypofunction, and may be particularly useful at identifying partial vestibular deficits as occur in aging adults. PMID:27445793

  2. Association of gestational weight gain expectations with advice on actual weight gain

    USDA-ARS?s Scientific Manuscript database

    To examine pregnant women's gestational weight gain expectations/advice from various sources (i.e., self, family/friends, physician) and the impact of these sources of expectations/advice on actual measured gestational weight gain. Pregnant women (n=230, 87.4% Caucasian, second pregnancy) in a cohor...

  3. Toward Uniformity in Exchange Communication

    ERIC Educational Resources Information Center

    Shinn, Isabella

    1972-01-01

    Instant communication, characterized by brevity, should be the practice of exchange librarians trading titles on the international level. Guidelines for a multilingual, many-purpose form letter, which could achieve uniformity, are presented. (14 references) (Author/SJ)

  4. Weight Gain during Pregnancy

    MedlinePlus

    ... Global Map Premature Birth Report Cards Careers Archives Pregnancy Before or between pregnancies Nutrition, weight & fitness Prenatal ... fitness > Weight gain during pregnancy Weight gain during pregnancy E-mail to a friend Please fill in ...

  5. Asthma Triggers: Gain Control

    MedlinePlus

    ... Centers Asthma Contact Us Share Asthma Triggers: Gain Control Breathing Freely: Controlling Asthma Triggers This video features ... Air Quality: Biological Pollutants Help Your Child Gain Control Over Asthma Top of Page Molds About Molds ...

  6. Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, David R.; Crawford, Aladsair J.; Fuller, Jason C.

    The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL 22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol,more » this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance.« less

  7. Exact Harmonic Metric for a Uniformly Moving Schwarzschild Black Hole

    NASA Astrophysics Data System (ADS)

    He, Guan-Sheng; Lin, Wen-Bin

    2014-02-01

    The harmonic metric for Schwarzschild black hole with a uniform velocity is presented. In the limit of weak field and low velocity, this metric reduces to the post-Newtonian approximation for one moving point mass. As an application, we derive the dynamics of particle and photon in the weak-field limit for the moving Schwarzschild black hole with an arbitrary velocity. It is found that the relativistic motion of gravitational source can induce an additional centripetal force on the test particle, which may be comparable to or even larger than the conventional Newtonian gravitational force.

  8. Gain and noise figure enhancement of Er+3/Yb+3 co-doped fiber/Raman hybrid amplifier

    NASA Astrophysics Data System (ADS)

    Mahran, O.

    2016-02-01

    An Er/Yb co-doped fiber/Raman hybrid amplifier (HA) is proposed and studied theoretically and analytically to improve the gain and noise figure of optical amplifiers. The calculations are performed under a uniform dopant and steady-state conditions. The initial energy transfer efficiency for Er/Yb co-doped fiber amplifier (EYDFA) is introduced, while the amplified spontaneous emission (ASE) is neglected. The glass fiber used for both Er/Yb and Raman amplifiers is phosphate. Different pump powers are used for both EYDFA and RA with 1 μW input signal power, 1 m length of Er/Yb amplifier and 25 km length of Raman amplifier (RA). The proposed model is validated for Er/Yb co-doped amplifier and Raman amplifier separately by comparing the calculating results with the experimental data. A high gain and low noise figure at 200 mW Raman pump power and 500 mW Er/Yb pump power are obtained for the proposed HA as compared with the experimental results of EYDFA, Raman amplifier and the EDFA/Raman hybrid amplifier.

  9. Uniform sunlight concentration reflectors for photovoltaic cells.

    PubMed

    Rabady, Rabi Ibrahim

    2014-03-20

    Sunlight concentration is essential to reach high temperatures of a working fluid in solar-thermal applications and to reduce the cost of photovoltaic (PV) electricity generation systems. Commonly, sunlight concentration is realized by parabolic or cylindrical reflectors, which do not provide uniform concentration on the receiver finite surface. Uniform concentration of sunlight is favored especially for the PV conversion applications since it not only enhances the conversion efficiency of sunlight but also reduces the thermal variations along the receiving PV cell, which can be a performance and life-span limiting factor. In this paper a reflector profile that uniformly infiltrates the concentrated sunlight into the receiving unit is attempted. The new design accounts for all factors that contribute to the nonuniform concentration, like the reflector curvature, which spatially reflects the sunlight nonuniformly, and the angular dependency of both the reflector reflectivity and the sunlight transmission through the PV cell.

  10. Perceptual uniformity of commonly used color spaces

    NASA Astrophysics Data System (ADS)

    Avanaki, Ali; Espig, Kathryn; Kimpe, Tom; Xthona, Albert; Marchessoux, Cedric; Rostang, Johan; Piepers, Bastian

    2014-03-01

    Use of color images in medical imaging has increased significantly the last few years. Color information is essential for applications such as ophthalmology, dermatology and clinical photography. Use of color at least brings benefits for other applications such as endoscopy, laparoscopy and digital pathology. Remarkably, as of today, there is no agreed standard on how color information needs to be visualized for medical applications. This lack of standardization results in large variability of how color images are visualized and it makes quality assurance a challenge. For this reason FDA and ICC recently organized a joint summit on color in medical imaging (CMI). At this summit, one of the suggestions was that modalities such as digital pathology could benefit from using a perceptually uniform color space (T. Kimpe, "Color Behavior of Medical Displays," CMI presentation, May 2013). Perceptually uniform spaces have already been used for many years in the radiology community where the DICOM GSDF standard provides linearity in luminance but not in color behavior. In this paper we quantify perceptual uniformity, using CIE's ΔE2000 as a color distance metric, of several color spaces that are typically used for medical applications. We applied our method to theoretical color spaces Gamma 1.8, 2.0, & 2.2, standard sRGB, and DICOM (correction LUT for gray applied to all primaries). In addition, we also measured color spaces (i.e., native behavior) of a high-end medical display (Barco Coronis Fusion 6MP DL, MDCC-6130), and a consumer display (Dell 1907FP). Our results indicate that sRGB & the native color space on the Barco Coronis Fusion exhibit the least non-uniformity within their group. However, the remaining degree of perceptual non-uniformity is still significant and there is room for improvement.

  11. Bus Testing Program

    DOT National Transportation Integrated Search

    1993-01-01

    The Bus Testing Program of the Federal Transit Administration was established in response to the requirements of the Surface Transportation and Uniform Relocation Assistance Act (STURAA) of 1987. Under the program, testing is required on all new mode...

  12. Water quality in Gaines Creek and Gaines Creek arm of Eufaula Lake, Oklahoma

    USGS Publications Warehouse

    Kurklin, J.K.

    1990-01-01

    Based on samples collected from May 1978 to May 1980 and analyzed for major anions, nitrogen, trace elements, phytoplankton, and bacteria, the water in Gaines Creek and the Gaines Creek arm of Eufaula Lake was similar with respect to suitability for municipal use. Water from Gaines Creek had a pH range of 5.7 to 7.6 and a maximum specific conductance of 97 microsiemens per centimeter at 25o Celsius, whereas water from the Gaines Creek arm of Eufaula Lake had a pH range of 6.0 to 9.2 and a maximum specific conductance of 260 microsiemens per centimeter at 25o Celsius. Dissolved oxygen, pH, temperature, and specific conductance values for the lake varied with depth. With the exceptions of cadmium, iron, lead, and manganese, trace-element determinations of samples were within recommended national primary and secondary drinking-water standards. When compared to the National Academy of Sciences water-quality criteria, phytoplankton and bacteria counts exceeded recommendations; however, water from either Gaines Creek or Eufaula Lake could be treated similarly and used as a municipal water supply.

  13. Chemical vapor deposition reactor. [providing uniform film thickness

    NASA Technical Reports Server (NTRS)

    Chern, S. S.; Maserjian, J. (Inventor)

    1977-01-01

    An improved chemical vapor deposition reactor is characterized by a vapor deposition chamber configured to substantially eliminate non-uniformities in films deposited on substrates by control of gas flow and removing gas phase reaction materials from the chamber. Uniformity in the thickness of films is produced by having reactive gases injected through multiple jets which are placed at uniformally distributed locations. Gas phase reaction materials are removed through an exhaust chimney which is positioned above the centrally located, heated pad or platform on which substrates are placed. A baffle is situated above the heated platform below the mouth of the chimney to prevent downdraft dispersion and scattering of gas phase reactant materials.

  14. Selective spectrofluorimetric method for determination of Lisinopril in pharmaceutical preparations and in presence of hydrochlorothiazide: Application to content uniformity testing.

    PubMed

    Derayea, Sayed M; Badr El-Din, Khalid M; Mohammed, Fatma F

    2017-12-01

    A novel sensitive and cost-effective spectrofluorimetric method has been developed and validated for determination of lisinopril (an angiotensin converting enzyme inhibitor) in its pure form and pharmaceutical preparations. The method is based on the reaction of the drug with ninhydrin and phenylacetaldehyde in buffered medium (pH 7.0) to form a highly fluorescent product measured at 460 nm after excitation at 390 nm. Different experimental parameters were optimized and calibration curve was constructed. The fluorescence-concentration relationship was linear in the range of 0.15-4.0 μg mL -1 . The calculated Limit of detection (LOD) and Limit of quantitation (LOQ) were 0.04 and 0.12 μg mL -1 , respectively. The method was successfully applied for the analysis of pharmaceutical preparations containing the studied drug either alone or co-formulated with hydrochlorothiazide. The obtained results were in agreement with those of the reported method in respect to accuracy and precession. Moreover, the method was applied content uniformity testing according to United States Pharmacopeia (USP) guidelines. Copyright © 2017 John Wiley & Sons, Ltd.

  15. The Uniformly Accelerated Reference Frame

    ERIC Educational Resources Information Center

    Hamilton, J. Dwayne

    1978-01-01

    The observations that would be made by a uniformly accelerated observer, including the observer's event horizon, the variation of clock rates with position, and the effects of following a freely falling object are considered in detail. (SL)

  16. The non-uniformity of fossil preservation.

    PubMed

    Holland, Steven M

    2016-07-19

    The fossil record provides the primary source of data for calibrating the origin of clades. Although minimum ages of clades are given by the oldest preserved fossil, these underestimate the true age, which must be bracketed by probabilistic methods based on multiple fossil occurrences. Although most of these methods assume uniform preservation rates, this assumption is unsupported over geological timescales. On geologically long timescales (more than 10 Myr), the origin and cessation of sedimentary basins, and long-term variations in tectonic subsidence, eustatic sea level and sedimentation rate control the availability of depositional facies that preserve the environments in which species lived. The loss of doomed sediments, those with a low probability of preservation, imparts a secular trend to fossil preservation. As a result, the fossil record is spatially and temporally non-uniform. Models of fossil preservation should reflect this non-uniformity by using empirical estimates of fossil preservation that are spatially and temporally partitioned, or by using indirect proxies of fossil preservation. Geologically, realistic models of preservation will provide substantially more reliable estimates of the origination of clades.This article is part of the themed issue 'Dating species divergences using rocks and clocks'. © 2016 The Author(s).

  17. The non-uniformity of fossil preservation

    PubMed Central

    2016-01-01

    The fossil record provides the primary source of data for calibrating the origin of clades. Although minimum ages of clades are given by the oldest preserved fossil, these underestimate the true age, which must be bracketed by probabilistic methods based on multiple fossil occurrences. Although most of these methods assume uniform preservation rates, this assumption is unsupported over geological timescales. On geologically long timescales (more than 10 Myr), the origin and cessation of sedimentary basins, and long-term variations in tectonic subsidence, eustatic sea level and sedimentation rate control the availability of depositional facies that preserve the environments in which species lived. The loss of doomed sediments, those with a low probability of preservation, imparts a secular trend to fossil preservation. As a result, the fossil record is spatially and temporally non-uniform. Models of fossil preservation should reflect this non-uniformity by using empirical estimates of fossil preservation that are spatially and temporally partitioned, or by using indirect proxies of fossil preservation. Geologically, realistic models of preservation will provide substantially more reliable estimates of the origination of clades. This article is part of the themed issue ‘Dating species divergences using rocks and clocks’. PMID:27325828

  18. Performance and Uniformity of Mass-Produced SIS Mixers for ALMA Band 8 Receiver Cartridges

    NASA Astrophysics Data System (ADS)

    Tomura, Tomonuri; Noguchi, Takashi; Sekimoto, Yutaro; Shan, Wenlei; Sato, Naohisa; Iizuka, Yoshizo; Kumagai, Kazuyoshi; Niizeki, Yasuaki; Iwakuni, Mikio; Ito, Tetsuya

    2015-05-01

    The Atacama large millimeter/submillimeter array (ALMA), which was jointly built in Chile by Europe, North America and East Asia, has an observational band from 30 to 950 GHz [1], [2]. We developed receiver cartridges for ALMA Band 8 (385-500 GHz) [3]-[5] which is one of ALMA 10 frequency bands. The Band 8 receiver cartridges were produced as 73 cartridges, and 292 SIS mixers were installed in their cartridges. Also, their all cartridges were required to meet following ALMA specifications: 1. The noise temperature is less than 196 K over 80% of the frequency range and less than 292 K at any frequency from 385 to 500 GHz. 2. The image rejection ratio is larger than 10 dB over 90% of the frequency range. 3. The IF output power variation is less than 7.0 dB peak-to-peak in the 4-8 GHz band. 4. The gain compression to RF load temperatures between 77 and 373 K is less than 5%. 5. The Allan variance of the IF output power is less than 4.0×10-7 in the time scale of 0.05 s≤T≤100 s and 3.0×10-6 at 300 s. To meet these specifications, the performance and uniformity of the SIS mixers are crucial. The SIS mixers with Nb/Al-AlOx/Nb superconductor-insulator-superconductor (SIS) tunnel junctions were fabricated in a clean room of National Astronomical Observatory of Japan and over 1000 mixer chips were mass-produced. After screening these mixers, 73 Band 8 receivers were assembled and tested. We report the test results of the mass-produced mixers and the receiver cartridges in detail from a statistical point of view.

  19. A Quasi-3-D Theory for Impedance Eduction in Uniform Grazing Flow

    NASA Technical Reports Server (NTRS)

    Watson, W. R.; Jones, M. G.; Parrott, T. L.

    2005-01-01

    A 2-D impedance eduction methodology is extended to quasi-3-D sound fields in uniform or shearing mean flow. We introduce a nonlocal, nonreflecting boundary condition to terminate the duct and then educe the impedance by minimizing an objective function. The introduction of a parallel, sparse, equation solver significantly reduces the wall clock time for educing the impedance when compared to that of the sequential band solver used in the 2-D methodology. The accuracy, efficiency, and robustness of the methodology is demonstrated using two examples. In the first example, we show that the method reproduces the known impedance of a ceramic tubular test liner. In the second example, we illustrate that the approach educes the impedance of a four-segment liner where the first, second, and fourth segments consist of a perforated face sheet bonded to honeycomb, and the third segment is a cut from the ceramic tubular test liner. The ability of the method to educe the impedances of multisegmented liners has the potential to significantly reduce the amount of time and cost required to determine the impedance of several uniform liners by allowing them to be placed in series in the test section and to educe the impedance of each segment using a single numerical experiment. Finally, we probe the objective function in great detail and show that it contains a single minimum. Thus, our objective function is ideal for use with local, inexpensive, gradient-based optimizers.

  20. Comparison of test particle acceleration in torsional spine and fan reconnection regimes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosseinpour, M., E-mail: hosseinpour@tabrizu.ac.ir; Mehdizade, M.; Mohammadi, M. A.

    2014-10-15

    Magnetic reconnection is a common phenomenon taking place in astrophysical and space plasmas, especially in solar flares which are rich sources of highly energetic particles. Torsional spine and fan reconnections are important mechanisms proposed for steady-state three-dimensional null-point reconnection. By using the magnetic and electric fields for these regimes, we numerically investigate the features of test particle acceleration in both regimes with input parameters for the solar corona. By comparison, torsional spine reconnection is found to be more efficient than torsional fan reconnection in an acceleration of a proton to a high kinetic energy. A proton can gain as highmore » as 100 MeV of relativistic kinetic energy within only a few milliseconds. Moreover, in torsional spine reconnection, an accelerated particle can escape either along the spine axis or on the fan plane depending on its injection position. However, in torsional fan reconnection, the particle is only allowed to accelerate along the spine axis. In addition, in both regimes, the particle's trajectory and final kinetic energy depend on the injection position but adopting either spatially uniform or non-uniform localized plasma resistivity does not much influence the features of trajectory.« less

  1. Examining Maternal Weight Gain During Contingency-Management Treatment for Smoking Cessation Among Pregnant Women

    PubMed Central

    Washio, Yukiko; Higgins, Stephen T.; Heil, Sarah H.; Badger, Gary J.; Skelly, Joan; Bernstein, Ira M.; Solomon, Laura J.; Higgins, Tara M.; Lynch, Mary Ellen; Hanson, Jennifer D.

    2010-01-01

    Excessive maternal weight gain during pregnancy can result in serious adverse maternal and neonatal health consequences making it an important outcome to monitor in developing smoking-cessation interventions for pregnant women. Maternal weight gain was investigated in the present study with 154 pregnant participants in controlled trials investigating the efficacy of contingency management (CM) for smoking cessation. Women were assigned to either an abstinence-contingent condition wherein they earned vouchers exchangeable for retail items by abstaining from smoking or to a control condition where they received comparable vouchers independent of smoking status. Mean percent of negative smoking status tests throughout antepartum was greater in the incentive than control condition (45.2±4.6 vs. 15.5±2.4, p < .001) as was late-pregnancy point-prevalence abstinence (36% vs. 8%, p < .001) but maternal weight gain did not differ significantly between treatment conditions (15.0 ± 0.8 kg vs. 15.0 ± 0.9 kg, p = .97). In a comparison of women classified by smoking status rather than treatment condition, a greater percent of negative smoking status tests predicted significantly more weight gain (0.34 kg per 10% increase in negative tests), an effect that appeared to be attributable to women with greater abstinence having larger infants. This study shows no evidence of excessive maternal weight gain among pregnant women receiving a CM intervention for smoking cessation. PMID:20870365

  2. Washing and changing uniforms: is guidance being adhered to?

    PubMed

    Potter, Yvonne Camilla; Justham, David

    To allay public apprehension regarding the risk of nurses' uniforms transmitting healthcare-associated infections (HCAI), national and local guidelines have been issued to control use, laundry and storage. This paper aims to measure the knowledge of registered nurses (RNs) and healthcare assistants (HCAs) working within a rural NHS foundation Trust and their adherence to the local infection prevention and control (IPC) standard regarding uniforms through a Trust-wide audit. Stratified random sampling selected 597 nursing staff and 399 responded (67%) by completing a short questionnaire based on the local standard. Responses were coded and transferred to SPSS (v. 17) for analysis. The audit found that nursing staff generally adhere to the guidelines, changing their uniforms daily and immediately upon accidental soiling, and wearing plastic aprons where indicated. At home, staff normally machine-wash and then iron their uniforms at the hottest setting. Nevertheless, few observe the local direction to place their newly-laundered uniforms in protective covers. This paper recommends a re-audit to compare compliance rates with baseline figures and further research into the reasons why compliance is lacking to sanction interventions for improvement, such as providing relevant staff education and re-introducing appropriate changing facilities.

  3. Non-Uniform Thickness Electroactive Device

    NASA Technical Reports Server (NTRS)

    Su, Ji (Inventor); Harrison, Joycelyn S. (Inventor)

    2006-01-01

    An electroactive device comprises at least two layers of material, wherein at least one layer is an electroactive material and wherein at least one layer is of non-uniform thickness. The device can be produced in various sizes, ranging from large structural actuators to microscale or nanoscale devices. The applied voltage to the device in combination with the non-uniform thickness of at least one of the layers (electroactive and/or non-electroactive) controls the contour of the actuated device. The effective electric field is a mathematical function of the local layer thickness. Therefore, the local strain and the local bending/ torsion curvature are also a mathematical function of the local thickness. Hence the thinnest portion of the actuator offers the largest bending and/or torsion response. Tailoring of the layer thicknesses can enable complex motions to be achieved.

  4. Rayleigh surface acoustic wave as an efficient heating system for biological reactions: investigation of microdroplet temperature uniformity.

    PubMed

    Roux-Marchand, Thibaut; Beyssen, Denis; Sarry, Frederic; Elmazria, Omar

    2015-04-01

    When a microdroplet is put on the Rayleigh surface acoustic wave path, longitudinal waves are radiated into the liquid and induce several phenomena such as the wellknown surface acoustic wave streaming. At the same time, the temperature of the microdroplet increases as it has been shown. In this paper, we study the temperature uniformity of a microdroplet heated by Rayleigh surface acoustic wave for discrete microfluidic applications such as biological reactions. To precisely ascertain the temperature uniformity and not interfere with the biological reaction, we used an infrared camera. We then tested the temperature uniformity as a function of three parameters: the microdroplet volume, the Rayleigh surface acoustic wave frequency, and the continuous applied radio frequency power. Based on these results, we propose a new device structure to develop a future lab on a chip based on reaction temperatures.

  5. An efficient, maintenance free and approved method for spectroscopic control and monitoring of blend uniformity: The moving F-test.

    PubMed

    Besseling, Rut; Damen, Michiel; Tran, Thanh; Nguyen, Thanh; van den Dries, Kaspar; Oostra, Wim; Gerich, Ad

    2015-10-10

    Dry powder mixing is a wide spread Unit Operation in the Pharmaceutical industry. With the advent of in-line Near Infrared (NIR) Spectroscopy and Quality by Design principles, application of Process Analytical Technology to monitor Blend Uniformity (BU) is taking a more prominent role. Yet routine use of NIR for monitoring, let alone control of blending processes is not common in the industry, despite the improved process understanding and (cost) efficiency that it may offer. Method maintenance, robustness and translation to regulatory requirements have been important barriers to implement the method. This paper presents a qualitative NIR-BU method offering a convenient and compliant approach to apply BU control for routine operation and process understanding, without extensive calibration and method maintenance requirements. The method employs a moving F-test to detect the steady state of measured spectral variances and the endpoint of mixing. The fundamentals and performance characteristics of the method are first presented, followed by a description of the link to regulatory BU criteria, the method sensitivity and practical considerations. Applications in upscaling, tech transfer and commercial production are described, along with evaluation of the method performance by comparison with results from quantitative calibration models. A full application, in which end-point detection via the F-test controls the blending process of a low dose product, was successfully filed in Europe and Australia, implemented in commercial production and routinely used for about five years and more than 100 batches. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. 78 FR 50359 - Civilian Health and Medical Program of the Uniformed Services (CHAMPUS); TRICARE Uniform Health...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-19

    ... Organization (HMO) Benefit--Prime Enrollment Fee Exemption for Survivors of Active Duty Deceased Sponsors and... Enrollment Fee Exemption for Survivors of Active Duty Deceased Sponsors and Medically Retired Uniformed...

  7. Leading Gainful Employment Metric Reporting

    ERIC Educational Resources Information Center

    Powers, Kristina; MacPherson, Derek

    2016-01-01

    This chapter will address the importance of intercampus involvement in reporting of gainful employment student-level data that will be used in the calculation of gainful employment metrics by the U.S. Department of Education. The authors will discuss why building relationships within the institution is critical for effective gainful employment…

  8. A uniform geometrical optics and an extended uniform geometrical theory of diffraction for evaluating high frequency EM fields near smooth caustics and composite shadow boundaries

    NASA Technical Reports Server (NTRS)

    Constantinides, E. D.; Marhefka, R. J.

    1994-01-01

    A uniform geometrical optics (UGO) and an extended uniform geometrical theory of diffraction (EUTD) are developed for evaluating high frequency electromagnetic (EM) fields within transition regions associated with a two and three dimensional smooth caustic of reflected rays and a composite shadow boundary formed by the caustic termination or the confluence of the caustic with the reflection shadow boundary (RSB). The UGO is a uniform version of the classic geometrical optics (GO). It retains the simple ray optical expressions of classic GO and employs a new set of uniform reflection coefficients. The UGO also includes a uniform version of the complex GO ray field that exists on the dark side of the smooth caustic. The EUTD is an extension of the classic uniform geometrical theory of diffraction (UTD) and accounts for the non-ray optical behavior of the UGO reflected field near caustics by using a two-variable transition function in the expressions for the edge diffraction coefficients. It also uniformly recovers the classic UTD behavior of the edge diffracted field outside the composite shadow boundary transition region. The approach employed for constructing the UGO/EUTD solution is based on a spatial domain physical optics (PO) radiation integral representation for the fields which is then reduced using uniform asymptotic procedures. The UGO/EUTD analysis is also employed to investigate the far-zone RCS problem of plane wave scattering from two and three dimensional polynomial defined surfaces, and uniform reflection, zero-curvature, and edge diffraction coefficients are derived. Numerical results for the scattering and diffraction from cubic and fourth order polynomial strips are also shown and the UGO/EUTD solution is validated by comparison to an independent moment method (MM) solution. The UGO/EUTD solution is also compared with the classic GO/UTD solution. The failure of the classic techniques near caustics and composite shadow boundaries is clearly

  9. Optimal geometry toward uniform current density electrodes

    NASA Astrophysics Data System (ADS)

    Song, Yizhuang; Lee, Eunjung; Woo, Eung Je; Seo, Jin Keun

    2011-07-01

    Electrodes are commonly used to inject current into the human body in various biomedical applications such as functional electrical stimulation, defibrillation, electrosurgery, RF ablation, impedance imaging, and so on. When a highly conducting electrode makes direct contact with biological tissues, the induced current density has strong singularity along the periphery of the electrode, which may cause painful sensation or burn. Especially in impedance imaging methods such as the magnetic resonance electrical impedance tomography, we should avoid such singularity since more uniform current density underneath a current-injection electrode is desirable. In this paper, we study an optimal geometry of a recessed electrode to produce a well-distributed current density on the contact area under the electrode. We investigate the geometry of the electrode surface to minimize the edge singularity and produce nearly uniform current density on the contact area. We propose a mathematical framework for the uniform current density electrode and its optimal geometry. The theoretical results are supported by numerical simulations.

  10. Processing of materials for uniform field emission

    DOEpatents

    Pam, L.S.; Felter, T.E.; Talin, A.; Ohlberg, D.; Fox, C.; Han, S.

    1999-01-12

    This method produces a field emitter material having a uniform electron emitting surface and a low turn-on voltage. Field emitter materials having uniform electron emitting surfaces as large as 1 square meter and turn-on voltages as low as 16V/{micro}m can be produced from films of electron emitting materials such as polycrystalline diamond, diamond-like carbon, graphite and amorphous carbon by the method of the present invention. The process involves conditioning the surface of a field emitter material by applying an electric field to the surface, preferably by scanning the surface of the field emitter material with an electrode maintained at a fixed distance of at least 3 {micro}m above the surface of the field emitter material and at a voltage of at least 500V. In order to enhance the uniformity of electron emission the step of conditioning can be preceded by ion implanting carbon, nitrogen, argon, oxygen or hydrogen into the surface layers of the field emitter material. 2 figs.

  11. Processing of materials for uniform field emission

    DOEpatents

    Pam, Lawrence S.; Felter, Thomas E.; Talin, Alec; Ohlberg, Douglas; Fox, Ciaran; Han, Sung

    1999-01-01

    This method produces a field emitter material having a uniform electron emitting surface and a low turn-on voltage. Field emitter materials having uniform electron emitting surfaces as large as 1 square meter and turn-on voltages as low as 16V/.mu.m can be produced from films of electron emitting materials such as polycrystalline diamond, diamond-like carbon, graphite and amorphous carbon by the method of the present invention. The process involves conditioning the surface of a field emitter material by applying an electric field to the surface, preferably by scanning the surface of the field emitter material with an electrode maintained at a fixed distance of at least 3 .mu.m above the surface of the field emitter material and at a voltage of at least 500V. In order to enhance the uniformity of electron emission the step of conditioning can be preceeded by ion implanting carbon, nitrogen, argon, oxygen or hydrogen into the surface layers of the field emitter material.

  12. Psychosocial influences on weight gain attitudes and behaviors during pregnancy.

    PubMed

    Dipietro, Janet A; Millet, Sarah; Costigan, Kathleen A; Gurewitsch, Edith; Caulfield, Laura E

    2003-10-01

    To examine pregnant women's weight-related attitudes and behaviors in relation to a constellation of psychosocial characteristics, prepregnancy body habitus, and gestational weight gain. One hundred-thirty women with low-risk, normal pregnancies. Cross-sectional, observational study assessed attitudes about weight gain at 36 weeks' gestation. Psychosocial characteristics, including anxiety, depression, social support, emotionality, and pregnancy-specific and nonspecific stress appraisal were assessed between 28 and 36 weeks' gestation. Principal components factor analysis, Pearson correlations, t tests, and analysis of variance. A range of positive and negative attitudes about weight gain was expressed. Twenty-one percent (n=27) of the sample endorsed at least one weight-restrictive behavior during pregnancy. Women who reported more weight-restrictive behaviors were more anxious (r=.24, P<.01), depressed (r=.29,P<.001), angry (r=.29, P<.001), stressed (r=.23, P<.01), and felt less uplifted (r=-.21, P<.05) about their pregnancies in general. Higher Positive Pregnancy Body Image scores were associated with feeling better about the pregnancy in general (r=.35, P<.001), fewer depressive symptoms, and less anger (both r=.20, both P<.01). Women who were self conscious about their weight gain felt more hassled by their pregnancies (r=.21, P<.05), greater anger (r=.21, P<.05), and more support from partners (r=.22, P<.05). Prepregnancy body mass index was unrelated, but negative attitudes about weight gain existed even among women who gained within recommended ranges. Women's attitudes about weight gain in pregnancy are imbedded in their orientation toward pregnancy as well as their general psychological functioning. Effective nutrition counseling for pregnant women should include consideration of weight-restrictive behaviors, the degree to which the pregnancy is perceived as positive and uplifting, and whether weight gain attitudes may be associated with their

  13. Motor planning under temporal uncertainty is suboptimal when the gain function is asymmetric

    PubMed Central

    Ota, Keiji; Shinya, Masahiro; Kudo, Kazutoshi

    2015-01-01

    For optimal action planning, the gain/loss associated with actions and the variability in motor output should both be considered. A number of studies make conflicting claims about the optimality of human action planning but cannot be reconciled due to their use of different movements and gain/loss functions. The disagreement is possibly because of differences in the experimental design and differences in the energetic cost of participant motor effort. We used a coincident timing task, which requires decision making with constant energetic cost, to test the optimality of participant's timing strategies under four configurations of the gain function. We compared participant strategies to an optimal timing strategy calculated from a Bayesian model that maximizes the expected gain. We found suboptimal timing strategies under two configurations of the gain function characterized by asymmetry, in which higher gain is associated with higher risk of zero gain. Participants showed a risk-seeking strategy by responding closer than optimal to the time of onset/offset of zero gain. Meanwhile, there was good agreement of the model with actual performance under two configurations of the gain function characterized by symmetry. Our findings show that human ability to make decisions that must reflect uncertainty in one's own motor output has limits that depend on the configuration of the gain function. PMID:26236227

  14. Positive Gain Spirals at Work: From Job Resources to Work Engagement, Personal Initiative and Work-Unit Innovativeness

    ERIC Educational Resources Information Center

    Hakanen, Jari J.; Perhoniemi, Riku; Toppinen-Tanner, Salla

    2008-01-01

    The present cross-lagged panel study aimed to investigate the energizing power of job resources and related gain spirals. Drawing on Hobfoll's Conservation of Resources (COR) theory's rarely tested assumptions of cumulative resource gains and gain spirals a reciprocal process was expected: (1) job resources lead to work engagement and work…

  15. Cylindrically distributing optical fiber tip for uniform laser illumination of hollow organs

    NASA Astrophysics Data System (ADS)

    Buonaccorsi, Giovanni A.; Burke, T.; MacRobert, Alexander J.; Hill, P. D.; Essenpreis, Matthias; Mills, Timothy N.

    1993-05-01

    To predict the outcome of laser therapy it is important to possess, among other things, an accurate knowledge of the intensity and distribution of the laser light incident on the tissue. For irradiation of the internal surfaces of hollow organs, modified fiber tips can be used to shape the light distribution to best suit the treatment geometry. There exist bulb-tipped optical fibers emitting a uniform isotropic distribution of light suitable for the treatment of organs which approximate a spherical geometry--the bladder, for example. For the treatment of organs approximating a cylindrical geometry--e.g. the oesophagus--an optical fiber tip which emits a uniform cylindrical distribution of light is required. We report on the design, development and testing of such a device, the CLD fiber tip. The device was made from a solid polymethylmethacrylate (PMMA) rod, 27 mm in length and 4 mm in diameter. One end was shaped and 'silvered' to form a mirror which reflected the light emitted from the delivery fiber positioned at the other end of the rod. The shape of the mirror was such that the light fell with uniform intensity on the circumferential surface of the rod. This surface was coated with BaSO4 reflectance paint to couple the light out of the rod and onto the surface of the tissue.

  16. Sequence specific motor performance gains after memory consolidation in children and adolescents.

    PubMed

    Dorfberger, Shoshi; Adi-Japha, Esther; Karni, Avi

    2012-01-01

    Memory consolidation for a trained sequence of finger opposition movements, in 9- and 12-year-old children, was recently found to be significantly less susceptible to interference by a subsequent training experience, compared to that of 17-year-olds. It was suggested that, in children, the experience of training on any sequence of finger movements may affect the performance of the sequence elements, component movements, rather than the sequence as a unit; the latter has been implicated in the learning of the task by adults. This hypothesis implied a possible childhood advantage in the ability to transfer the gains from a trained to the reversed, untrained, sequence of movements. Here we report the results of transfer tests undertaken to test this proposal in 9-, 12-, and 17-year-olds after training in the finger-to-thumb opposition sequence (FOS) learning task. Our results show that the performance gains in the trained sequence partially transferred from the left, trained hand, to the untrained hand at 48-hours after a single training session in the three age-groups tested. However, there was very little transfer of the gains from the trained to the untrained, reversed, sequence performed by either hand. The results indicate sequence specific post-training gains in FOS performance, as opposed to a general improvement in performance of the individual, component, movements that comprised both the trained and untrained sequences. These results do not support the proposal that the reduced susceptibility to interference, in children before adolescence, reflects a difference in movement syntax representation after training.

  17. Modelling of the reactive sputtering process with non-uniform discharge current density and different temperature conditions

    NASA Astrophysics Data System (ADS)

    Vašina, P; Hytková, T; Eliáš, M

    2009-05-01

    The majority of current models of the reactive magnetron sputtering assume a uniform shape of the discharge current density and the same temperature near the target and the substrate. However, in the real experimental set-up, the presence of the magnetic field causes high density plasma to form in front of the cathode in the shape of a toroid. Consequently, the discharge current density is laterally non-uniform. In addition to this, the heating of the background gas by sputtered particles, which is usually referred to as the gas rarefaction, plays an important role. This paper presents an extended model of the reactive magnetron sputtering that assumes the non-uniform discharge current density and which accommodates the gas rarefaction effect. It is devoted mainly to the study of the behaviour of the reactive sputtering rather that to the prediction of the coating properties. Outputs of this model are compared with those that assume uniform discharge current density and uniform temperature profile in the deposition chamber. Particular attention is paid to the modelling of the radial variation of the target composition near transitions from the metallic to the compound mode and vice versa. A study of the target utilization in the metallic and compound mode is performed for two different discharge current density profiles corresponding to typical two pole and multipole magnetics available on the market now. Different shapes of the discharge current density were tested. Finally, hysteresis curves are plotted for various temperature conditions in the reactor.

  18. Polygenic Risk, Appetite Traits, and Weight Gain in Middle Childhood

    PubMed Central

    Steinsbekk, Silje; Belsky, Daniel; Guzey, Ismail Cuneyt; Wardle, Jane; Wichstrøm, Lars

    2018-01-01

    IMPORTANCE Genome-wide association studies have identified genetic risks for obesity. These genetic risks influence development of obesity partly by accelerating weight gain in childhood. Research is needed to identify mechanisms to inform intervention. Cross-sectional studies suggest appetite traits as a candidate mechanism. Longitudinal studies are needed to test whether appetite traits mediate genetic influences on children’s weight gain. OBJECTIVE To test whether genetic risk for obesity predicts accelerated weight gain in middle childhood (ages 4–8 years) and whether genetic association with accelerated weight gain is mediated by appetite traits. DESIGN, SETTING, AND PARTICIPANTS Longitudinal study of a representative birth cohort at the Trondheim Early Secure Study, Trondheim, Norway, enrolled at age 4 years during 2007 to 2008, with follow-ups at ages 6 and 8 years. Participants were sampled from all children born in 2003 or 2004 who attended regular community health checkups for 4-year-olds (97.2%attendance; 82.0%consent rate, n = 2475). Nine hundred ninety-five children participated at age 4 years, 795 at age 6 years, and 699 at age 8 years. Analyses included 652 children with genotype, adiposity, and appetite data. MAIN OUTCOMES AND MEASURES Outcomes were body mass index and body-fat phenotypes measured from anthropometry (ages 4, 6, and 8 years) and bioelectrical impedance (ages 6 and 8 years). Genetic risk for obesity was measured using a genetic risk score composed of 32 single-nucleotide polymorphisms previously discovered in genome-wide association studies of adult body mass index. Appetite traits were measured at age 6 years with the Children’s Eating Behavior Questionnaire. RESULTS Of the 652 genotyped child participants, 323 (49.5%) were female, 58 (8.9%) were overweight, and 1 (0.2%) was obese. Children at higher genetic risk for obesity had higher baseline body mass index and fat mass compared with lower genetic risk peers, and they gained

  19. Switched-Observer-Based Adaptive Neural Control of MIMO Switched Nonlinear Systems With Unknown Control Gains.

    PubMed

    Long, Lijun; Zhao, Jun

    2017-07-01

    In this paper, the problem of adaptive neural output-feedback control is addressed for a class of multi-input multioutput (MIMO) switched uncertain nonlinear systems with unknown control gains. Neural networks (NNs) are used to approximate unknown nonlinear functions. In order to avoid the conservativeness caused by adoption of a common observer for all subsystems, an MIMO NN switched observer is designed to estimate unmeasurable states. A new switched observer-based adaptive neural control technique for the problem studied is then provided by exploiting the classical average dwell time (ADT) method and the backstepping method and the Nussbaum gain technique. It effectively handles the obstacle about the coexistence of multiple Nussbaum-type function terms, and improves the classical ADT method, since the exponential decline property of Lyapunov functions for individual subsystems is no longer satisfied. It is shown that the technique proposed is able to guarantee semiglobal uniformly ultimately boundedness of all the signals in the closed-loop system under a class of switching signals with ADT, and the tracking errors converge to a small neighborhood of the origin. The effectiveness of the approach proposed is illustrated by its application to a two inverted pendulum system.

  20. Fixed gain and adaptive techniques for rotorcraft vibration control

    NASA Technical Reports Server (NTRS)

    Roy, R. H.; Saberi, H. A.; Walker, R. A.

    1985-01-01

    The results of an analysis effort performed to demonstrate the feasibility of employing approximate dynamical models and frequency shaped cost functional control law desgin techniques for helicopter vibration suppression are presented. Both fixed gain and adaptive control designs based on linear second order dynamical models were implemented in a detailed Rotor Systems Research Aircraft (RSRA) simulation to validate these active vibration suppression control laws. Approximate models of fuselage flexibility were included in the RSRA simulation in order to more accurately characterize the structural dynamics. The results for both the fixed gain and adaptive approaches are promising and provide a foundation for pursuing further validation in more extensive simulation studies and in wind tunnel and/or flight tests.