Sample records for gait analysis methods

  1. Gait Analysis Using Wearable Sensors

    PubMed Central

    Tao, Weijun; Liu, Tao; Zheng, Rencheng; Feng, Hutian

    2012-01-01

    Gait analysis using wearable sensors is an inexpensive, convenient, and efficient manner of providing useful information for multiple health-related applications. As a clinical tool applied in the rehabilitation and diagnosis of medical conditions and sport activities, gait analysis using wearable sensors shows great prospects. The current paper reviews available wearable sensors and ambulatory gait analysis methods based on the various wearable sensors. After an introduction of the gait phases, the principles and features of wearable sensors used in gait analysis are provided. The gait analysis methods based on wearable sensors is divided into gait kinematics, gait kinetics, and electromyography. Studies on the current methods are reviewed, and applications in sports, rehabilitation, and clinical diagnosis are summarized separately. With the development of sensor technology and the analysis method, gait analysis using wearable sensors is expected to play an increasingly important role in clinical applications. PMID:22438763

  2. Basic gait analysis based on continuous wave radar.

    PubMed

    Zhang, Jun

    2012-09-01

    A gait analysis method based on continuous wave (CW) radar is proposed in this paper. Time-frequency analysis is used to analyze the radar micro-Doppler echo from walking humans, and the relationships between the time-frequency spectrogram and human biological gait are discussed. The methods for extracting the gait parameters from the spectrogram are studied in depth and experiments on more than twenty subjects have been performed to acquire the radar gait data. The gait parameters are calculated and compared. The gait difference between men and women are presented based on the experimental data and extracted features. Gait analysis based on CW radar will provide a new method for clinical diagnosis and therapy. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Automated Gait Analysis Through Hues and Areas (AGATHA): a method to characterize the spatiotemporal pattern of rat gait

    PubMed Central

    Kloefkorn, Heidi E.; Pettengill, Travis R.; Turner, Sara M. F.; Streeter, Kristi A.; Gonzalez-Rothi, Elisa J.; Fuller, David D.; Allen, Kyle D.

    2016-01-01

    While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns. PMID:27554674

  4. Automated Gait Analysis Through Hues and Areas (AGATHA): A Method to Characterize the Spatiotemporal Pattern of Rat Gait.

    PubMed

    Kloefkorn, Heidi E; Pettengill, Travis R; Turner, Sara M F; Streeter, Kristi A; Gonzalez-Rothi, Elisa J; Fuller, David D; Allen, Kyle D

    2017-03-01

    While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns.

  5. Assessment of Gait Characteristics in Total Knee Arthroplasty Patients Using a Hierarchical Partial Least Squares Method.

    PubMed

    Wang, Wei; Ackland, David C; McClelland, Jodie A; Webster, Kate E; Halgamuge, Saman

    2018-01-01

    Quantitative gait analysis is an important tool in objective assessment and management of total knee arthroplasty (TKA) patients. Studies evaluating gait patterns in TKA patients have tended to focus on discrete data such as spatiotemporal information, joint range of motion and peak values of kinematics and kinetics, or consider selected principal components of gait waveforms for analysis. These strategies may not have the capacity to capture small variations in gait patterns associated with each joint across an entire gait cycle, and may ultimately limit the accuracy of gait classification. The aim of this study was to develop an automatic feature extraction method to analyse patterns from high-dimensional autocorrelated gait waveforms. A general linear feature extraction framework was proposed and a hierarchical partial least squares method derived for discriminant analysis of multiple gait waveforms. The effectiveness of this strategy was verified using a dataset of joint angle and ground reaction force waveforms from 43 patients after TKA surgery and 31 healthy control subjects. Compared with principal component analysis and partial least squares methods, the hierarchical partial least squares method achieved generally better classification performance on all possible combinations of waveforms, with the highest classification accuracy . The novel hierarchical partial least squares method proposed is capable of capturing virtually all significant differences between TKA patients and the controls, and provides new insights into data visualization. The proposed framework presents a foundation for more rigorous classification of gait, and may ultimately be used to evaluate the effects of interventions such as surgery and rehabilitation.

  6. Analysis of Big Data in Gait Biomechanics: Current Trends and Future Directions.

    PubMed

    Phinyomark, Angkoon; Petri, Giovanni; Ibáñez-Marcelo, Esther; Osis, Sean T; Ferber, Reed

    2018-01-01

    The increasing amount of data in biomechanics research has greatly increased the importance of developing advanced multivariate analysis and machine learning techniques, which are better able to handle "big data". Consequently, advances in data science methods will expand the knowledge for testing new hypotheses about biomechanical risk factors associated with walking and running gait-related musculoskeletal injury. This paper begins with a brief introduction to an automated three-dimensional (3D) biomechanical gait data collection system: 3D GAIT, followed by how the studies in the field of gait biomechanics fit the quantities in the 5 V's definition of big data: volume, velocity, variety, veracity, and value. Next, we provide a review of recent research and development in multivariate and machine learning methods-based gait analysis that can be applied to big data analytics. These modern biomechanical gait analysis methods include several main modules such as initial input features, dimensionality reduction (feature selection and extraction), and learning algorithms (classification and clustering). Finally, a promising big data exploration tool called "topological data analysis" and directions for future research are outlined and discussed.

  7. Quantification and recognition of parkinsonian gait from monocular video imaging using kernel-based principal component analysis

    PubMed Central

    2011-01-01

    Background The computer-aided identification of specific gait patterns is an important issue in the assessment of Parkinson's disease (PD). In this study, a computer vision-based gait analysis approach is developed to assist the clinical assessments of PD with kernel-based principal component analysis (KPCA). Method Twelve PD patients and twelve healthy adults with no neurological history or motor disorders within the past six months were recruited and separated according to their "Non-PD", "Drug-On", and "Drug-Off" states. The participants were asked to wear light-colored clothing and perform three walking trials through a corridor decorated with a navy curtain at their natural pace. The participants' gait performance during the steady-state walking period was captured by a digital camera for gait analysis. The collected walking image frames were then transformed into binary silhouettes for noise reduction and compression. Using the developed KPCA-based method, the features within the binary silhouettes can be extracted to quantitatively determine the gait cycle time, stride length, walking velocity, and cadence. Results and Discussion The KPCA-based method uses a feature-extraction approach, which was verified to be more effective than traditional image area and principal component analysis (PCA) approaches in classifying "Non-PD" controls and "Drug-Off/On" PD patients. Encouragingly, this method has a high accuracy rate, 80.51%, for recognizing different gaits. Quantitative gait parameters are obtained, and the power spectrums of the patients' gaits are analyzed. We show that that the slow and irregular actions of PD patients during walking tend to transfer some of the power from the main lobe frequency to a lower frequency band. Our results indicate the feasibility of using gait performance to evaluate the motor function of patients with PD. Conclusion This KPCA-based method requires only a digital camera and a decorated corridor setup. The ease of use and installation of the current method provides clinicians and researchers a low cost solution to monitor the progression of and the treatment to PD. In summary, the proposed method provides an alternative to perform gait analysis for patients with PD. PMID:22074315

  8. Gait Analysis Methods for Rodent Models of Osteoarthritis

    PubMed Central

    Jacobs, Brittany Y.; Kloefkorn, Heidi E.; Allen, Kyle D.

    2014-01-01

    Patients with osteoarthritis (OA) primarily seek treatment due to pain and disability, yet the primary endpoints for rodent OA models tend to be histological measures of joint destruction. The discrepancy between clinical and preclinical evaluations is problematic, given that radiographic evidence of OA in humans does not always correlate to the severity of patient-reported symptoms. Recent advances in behavioral analyses have provided new methods to evaluate disease sequelae in rodents. Of particular relevance to rodent OA models are methods to assess rodent gait. While obvious differences exist between quadrupedal and bipedal gait sequences, the gait abnormalities seen in humans and in rodent OA models reflect similar compensatory behaviors that protect an injured limb from loading. The purpose of this review is to describe these compensations and current methods used to assess rodent gait characteristics, while detailing important considerations for the selection of gait analysis methods in rodent OA models. PMID:25160712

  9. Comparison of a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography.

    PubMed

    Stuberg, W A; Colerick, V L; Blanke, D J; Bruce, W

    1988-08-01

    The purpose of this study was to compare a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography in a gait analysis laboratory. Ten children with a diagnosis of cerebral palsy (means age = 8.8 +/- 2.7 years) and 9 healthy children (means age = 8.9 +/- 2.4 years) participated in the study. Stride length, walking velocity, and goniometric measurements of the hip, knee, and ankle were recorded using the two gait analysis methods. A multivariate analysis of variance was used to determine significant differences between the data collected using the two methods. Pearson product-moment correlation coefficients were determined to examine the relationship between the measurements recorded by the two methods. The consistency of performance of the subjects during walking was examined by intraclass correlation coefficients. No significant differences were found between the methods for the variables studied. Pearson product-moment correlation coefficients ranged from .79 to .95, and intraclass coefficients ranged from .89 to .97. The clinical gait analysis method was found to be a valid tool in comparison with 16-mm cinematography for the variables that were studied.

  10. Analysis of gait patterns pre- and post- Single Event Multilevel Surgery in children with Cerebral Palsy by means of Offset-Wise Movement Analysis Profile and Linear Fit Method.

    PubMed

    Ancillao, Andrea; van der Krogt, Marjolein M; Buizer, Annemieke I; Witbreuk, Melinda M; Cappa, Paolo; Harlaar, Jaap

    2017-10-01

    Gait analysis is used for the assessment of walking ability of children with cerebral palsy (CP), to inform clinical decision making and to quantify changes after treatment. To simplify gait analysis interpretation and to quantify deviations from normality, some quantitative synthetic descriptors were developed over the years, such as the Movement Analysis Profile (MAP) and the Linear Fit Method (LFM), but their interpretation is not always straightforward. The aims of this work were to: (i) study gait changes, by means of synthetic descriptors, in children with CP that underwent Single Event Multilevel Surgery; (ii) compare the MAP and the LFM on these patients; (iii) design a new index that may overcome the limitations of the previous methods, i.e. the lack of information about the direction of deviation or its source. Gait analysis exams of 10 children with CP, pre- and post-surgery, were collected and MAP and LFM were computed. A new index was designed asa modified version of the MAP by separating out changes in offset (named OC-MAP). MAP documented an improvement in the gait pattern after surgery. The highest effect was observed for the knee flexion/extension angle. However, a worsening was observed as an increase in anterior pelvic tilt. An important source of gait deviation was recognized in the offset between observed tracks and reference. OC-MAP allowed the assessment of the offset component versus the shape component of deviation. LFM provided results similar to OC-MAP offset analysis but could not be considered reliable due to intrinsic limitations. As offset in gait features played an important role in gait deviation, OC-MAP synthetic analysis was proposed as a novel approach to a meaningful parameterisation of global deviations in gait patterns of subjects with CP and gait changes after treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Gait Analysis Methods for Rodent Models of Arthritic Disorders: Reviews and Recommendations

    PubMed Central

    Lakes, Emily H.; Allen, Kyle D.

    2016-01-01

    Gait analysis is a useful tool to understand behavioral changes in preclinical arthritis models. While observational scoring and spatiotemporal gait parameters are the most widely performed gait analyses in rodents, commercially available systems can now provide quantitative assessments of spatiotemporal patterns. However, inconsistencies remain between testing platforms, and laboratories often select different gait pattern descriptors to report in the literature. Rodent gait can also be described through kinetic and kinematic analyses, but systems to analyze rodent kinetics and kinematics are typically custom made and often require sensitive, custom equipment. While the use of rodent gait analysis rapidly expands, it is important to remember that, while rodent gait analysis is a relatively modern behavioral assay, the study of quadrupedal gait is not new. Nearly all gait parameters are correlated, and a collection of gait parameters is needed to understand a compensatory gait pattern used by the animal. As such, a change in a single gait parameter is unlikely to tell the full biomechanical story; and to effectively use gait analysis, one must consider how multiple different parameters contribute to an altered gait pattern. The goal of this article is to review rodent gait analysis techniques and provide recommendations on how to use these technologies in rodent arthritis models, including discussions on the strengths and limitations of observational scoring, spatiotemporal, kinetic, and kinematic measures. Recognizing rodent gait analysis is an evolving tool, we also provide technical recommendations we hope will improve the utility of these analyses in the future. PMID:26995111

  12. Comparison of Gait Aspects According to FES Stimulation Position Applied to Stroke Patients

    PubMed Central

    Mun, Byeong-mu; Kim, Tae-ho; Lee, Jin-hwan; Lim, Jin-youg; Seo, Dong-kwon; Lee, Dong-jin

    2014-01-01

    [Purpose] This study sought to identify the gait aspects according to the FES stimulation position in stroke patients during gait training. [Subjects and Methods] To perform gait analysis, ten stroke patients were grouped based on 4 types of gait conditions: gait without FES stimulation (non-FES), gait with FES stimulation on the tibialis anterior (Ta), gait with FES stimulation on the tibialis anterior and quadriceps (TaQ), and gait with FES stimulation on the tibialis anterior and gluteus medius (TaGm). [Results] Based on repeated measures analysis of variance of measurements of gait aspects comprised of gait speed, gait cycle, and step length according to the FES stimulation position, the FES stimulation significantly affected gait aspects. [Conclusion] In conclusion, stimulating the tibialis anterior and quadriceps and stimulating the tibialis anterior and gluteus medius are much more effective than stimulating only the tibialis anterior during gait training in stroke patients using FES. PMID:24764634

  13. Two-dimensional PCA-based human gait identification

    NASA Astrophysics Data System (ADS)

    Chen, Jinyan; Wu, Rongteng

    2012-11-01

    It is very necessary to recognize person through visual surveillance automatically for public security reason. Human gait based identification focus on recognizing human by his walking video automatically using computer vision and image processing approaches. As a potential biometric measure, human gait identification has attracted more and more researchers. Current human gait identification methods can be divided into two categories: model-based methods and motion-based methods. In this paper a two-Dimensional Principal Component Analysis and temporal-space analysis based human gait identification method is proposed. Using background estimation and image subtraction we can get a binary images sequence from the surveillance video. By comparing the difference of two adjacent images in the gait images sequence, we can get a difference binary images sequence. Every binary difference image indicates the body moving mode during a person walking. We use the following steps to extract the temporal-space features from the difference binary images sequence: Projecting one difference image to Y axis or X axis we can get two vectors. Project every difference image in the difference binary images sequence to Y axis or X axis difference binary images sequence we can get two matrixes. These two matrixes indicate the styles of one walking. Then Two-Dimensional Principal Component Analysis(2DPCA) is used to transform these two matrixes to two vectors while at the same time keep the maximum separability. Finally the similarity of two human gait images is calculated by the Euclidean distance of the two vectors. The performance of our methods is illustrated using the CASIA Gait Database.

  14. Estimation of Temporal Gait Parameters Using a Wearable Microphone-Sensor-Based System

    PubMed Central

    Wang, Cheng; Wang, Xiangdong; Long, Zhou; Yuan, Jing; Qian, Yueliang; Li, Jintao

    2016-01-01

    Most existing wearable gait analysis methods focus on the analysis of data obtained from inertial sensors. This paper proposes a novel, low-cost, wireless and wearable gait analysis system which uses microphone sensors to collect footstep sound signals during walking. This is the first time a microphone sensor is used as a wearable gait analysis device as far as we know. Based on this system, a gait analysis algorithm for estimating the temporal parameters of gait is presented. The algorithm fully uses the fusion of two feet footstep sound signals and includes three stages: footstep detection, heel-strike event and toe-on event detection, and calculation of gait temporal parameters. Experimental results show that with a total of 240 data sequences and 1732 steps collected using three different gait data collection strategies from 15 healthy subjects, the proposed system achieves an average 0.955 F1-measure for footstep detection, an average 94.52% accuracy rate for heel-strike detection and 94.25% accuracy rate for toe-on detection. Using these detection results, nine temporal related gait parameters are calculated and these parameters are consistent with their corresponding normal gait temporal parameters and labeled data calculation results. The results verify the effectiveness of our proposed system and algorithm for temporal gait parameter estimation. PMID:27999321

  15. Gait Analysis by High School Students

    ERIC Educational Resources Information Center

    Heck, Andre; van Dongen, Caroline

    2008-01-01

    Human walking is a complicated motion. Movement scientists have developed various research methods to study gait. This article describes how a high school student collected and analysed high quality gait data in much the same way that movement scientists do, via the recording and measurement of motions with a video analysis tool and via…

  16. 2.5D multi-view gait recognition based on point cloud registration.

    PubMed

    Tang, Jin; Luo, Jian; Tjahjadi, Tardi; Gao, Yan

    2014-03-28

    This paper presents a method for modeling a 2.5-dimensional (2.5D) human body and extracting the gait features for identifying the human subject. To achieve view-invariant gait recognition, a multi-view synthesizing method based on point cloud registration (MVSM) to generate multi-view training galleries is proposed. The concept of a density and curvature-based Color Gait Curvature Image is introduced to map 2.5D data onto a 2D space to enable data dimension reduction by discrete cosine transform and 2D principle component analysis. Gait recognition is achieved via a 2.5D view-invariant gait recognition method based on point cloud registration. Experimental results on the in-house database captured by a Microsoft Kinect camera show a significant performance gain when using MVSM.

  17. Validity of the Kinect for Gait Assessment: A Focused Review

    PubMed Central

    Springer, Shmuel; Yogev Seligmann, Galit

    2016-01-01

    Gait analysis may enhance clinical practice. However, its use is limited due to the need for expensive equipment which is not always available in clinical settings. Recent evidence suggests that Microsoft Kinect may provide a low cost gait analysis method. The purpose of this report is to critically evaluate the literature describing the concurrent validity of using the Kinect as a gait analysis instrument. An online search of PubMed, CINAHL, and ProQuest databases was performed. Included were studies in which walking was assessed with the Kinect and another gold standard device, and consisted of at least one numerical finding of spatiotemporal or kinematic measures. Our search identified 366 papers, from which 12 relevant studies were retrieved. The results demonstrate that the Kinect is valid only for some spatiotemporal gait parameters. Although the kinematic parameters measured by the Kinect followed the trend of the joint trajectories, they showed poor validity and large errors. In conclusion, the Kinect may have the potential to be used as a tool for measuring spatiotemporal aspects of gait, yet standardized methods should be established, and future examinations with both healthy subjects and clinical participants are required in order to integrate the Kinect as a clinical gait analysis tool. PMID:26861323

  18. Gait Analysis From a Single Ear-Worn Sensor: Reliability and Clinical Evaluation for Orthopaedic Patients.

    PubMed

    Jarchi, Delaram; Lo, Benny; Wong, Charence; Ieong, Edmund; Nathwani, Dinesh; Yang, Guang-Zhong

    2016-08-01

    Objective assessment of detailed gait patterns after orthopaedic surgery is important for post-surgical follow-up and rehabilitation. The purpose of this paper is to assess the use of a single ear-worn sensor for clinical gait analysis. A reliability measure is devised for indicating the confidence level of the estimated gait events, allowing it to be used in free-walking environments and for facilitating clinical assessment of orthopaedic patients after surgery. Patient groups prior to or following anterior cruciate ligament (ACL) reconstruction and knee replacement were recruited to assess the proposed method. The ability of the sensor for detailed longitudinal analysis is demonstrated with a group of patients after lower limb reconstruction by considering parameters such as temporal and force-related gait asymmetry derived from gait events. The results suggest that the ear-worn sensor can be used for objective gait assessments of orthopaedic patients without the requirement and expense of an elaborate laboratory setup for gait analysis. It significantly simplifies the monitoring protocol and opens the possibilities for home-based remote patient assessment.

  19. 2.5D Multi-View Gait Recognition Based on Point Cloud Registration

    PubMed Central

    Tang, Jin; Luo, Jian; Tjahjadi, Tardi; Gao, Yan

    2014-01-01

    This paper presents a method for modeling a 2.5-dimensional (2.5D) human body and extracting the gait features for identifying the human subject. To achieve view-invariant gait recognition, a multi-view synthesizing method based on point cloud registration (MVSM) to generate multi-view training galleries is proposed. The concept of a density and curvature-based Color Gait Curvature Image is introduced to map 2.5D data onto a 2D space to enable data dimension reduction by discrete cosine transform and 2D principle component analysis. Gait recognition is achieved via a 2.5D view-invariant gait recognition method based on point cloud registration. Experimental results on the in-house database captured by a Microsoft Kinect camera show a significant performance gain when using MVSM. PMID:24686727

  20. Gait Analysis Methods: An Overview of Wearable and Non-Wearable Systems, Highlighting Clinical Applications

    PubMed Central

    Muro-de-la-Herran, Alvaro; Garcia-Zapirain, Begonya; Mendez-Zorrilla, Amaia

    2014-01-01

    This article presents a review of the methods used in recognition and analysis of the human gait from three different approaches: image processing, floor sensors and sensors placed on the body. Progress in new technologies has led the development of a series of devices and techniques which allow for objective evaluation, making measurements more efficient and effective and providing specialists with reliable information. Firstly, an introduction of the key gait parameters and semi-subjective methods is presented. Secondly, technologies and studies on the different objective methods are reviewed. Finally, based on the latest research, the characteristics of each method are discussed. 40% of the reviewed articles published in late 2012 and 2013 were related to non-wearable systems, 37.5% presented inertial sensor-based systems, and the remaining 22.5% corresponded to other wearable systems. An increasing number of research works demonstrate that various parameters such as precision, conformability, usability or transportability have indicated that the portable systems based on body sensors are promising methods for gait analysis. PMID:24556672

  1. On Gait Analysis Estimation Errors Using Force Sensors on a Smart Rollator

    PubMed Central

    Ballesteros, Joaquin; Urdiales, Cristina; Martinez, Antonio B.; van Dieën, Jaap H.

    2016-01-01

    Gait analysis can provide valuable information on a person’s condition and rehabilitation progress. Gait is typically captured using external equipment and/or wearable sensors. These tests are largely constrained to specific controlled environments. In addition, gait analysis often requires experts for calibration, operation and/or to place sensors on volunteers. Alternatively, mobility support devices like rollators can be equipped with onboard sensors to monitor gait parameters, while users perform their Activities of Daily Living. Gait analysis in rollators may use odometry and force sensors in the handlebars. However, force based estimation of gait parameters is less accurate than traditional methods, especially when rollators are not properly used. This paper presents an evaluation of force based gait analysis using a smart rollator on different groups of users to determine when this methodology is applicable. In a second stage, the rollator is used in combination with two lab-based gait analysis systems to assess the rollator estimation error. Our results show that: (i) there is an inverse relation between the variance in the force difference between handlebars and support on the handlebars—related to the user condition—and the estimation error; and (ii) this error is lower than 10% when the variation in the force difference is above 7 N. This lower limit was exceeded by the 95.83% of our challenged volunteers. In conclusion, rollators are useful for gait characterization as long as users really need the device for ambulation. PMID:27834911

  2. On Gait Analysis Estimation Errors Using Force Sensors on a Smart Rollator.

    PubMed

    Ballesteros, Joaquin; Urdiales, Cristina; Martinez, Antonio B; van Dieën, Jaap H

    2016-11-10

    Gait analysis can provide valuable information on a person's condition and rehabilitation progress. Gait is typically captured using external equipment and/or wearable sensors. These tests are largely constrained to specific controlled environments. In addition, gait analysis often requires experts for calibration, operation and/or to place sensors on volunteers. Alternatively, mobility support devices like rollators can be equipped with onboard sensors to monitor gait parameters, while users perform their Activities of Daily Living. Gait analysis in rollators may use odometry and force sensors in the handlebars. However, force based estimation of gait parameters is less accurate than traditional methods, especially when rollators are not properly used. This paper presents an evaluation of force based gait analysis using a smart rollator on different groups of users to determine when this methodology is applicable. In a second stage, the rollator is used in combination with two lab-based gait analysis systems to assess the rollator estimation error. Our results show that: (i) there is an inverse relation between the variance in the force difference between handlebars and support on the handlebars-related to the user condition-and the estimation error; and (ii) this error is lower than 10% when the variation in the force difference is above 7 N. This lower limit was exceeded by the 95.83% of our challenged volunteers. In conclusion, rollators are useful for gait characterization as long as users really need the device for ambulation.

  3. A perceptual map for gait symmetry quantification and pathology detection.

    PubMed

    Moevus, Antoine; Mignotte, Max; de Guise, Jacques A; Meunier, Jean

    2015-10-29

    The gait movement is an essential process of the human activity and the result of collaborative interactions between the neurological, articular and musculoskeletal systems, working efficiently together. This explains why gait analysis is important and increasingly used nowadays for the diagnosis of many different types (neurological, muscular, orthopedic, etc.) of diseases. This paper introduces a novel method to quickly visualize the different parts of the body related to an asymmetric movement in the human gait of a patient for daily clinical usage. The proposed gait analysis algorithm relies on the fact that the healthy walk has (temporally shift-invariant) symmetry properties in the coronal plane. The goal is to provide an inexpensive and easy-to-use method, exploiting an affordable consumer depth sensor, the Kinect, to measure the gait asymmetry and display results in a perceptual way. We propose a multi-dimensional scaling mapping using a temporally shift invariant distance, allowing us to efficiently visualize (in terms of perceptual color difference) the asymmetric body parts of the gait cycle of a subject. We also propose an index computed from this map and which quantifies locally and globally the degree of asymmetry. The proposed index is proved to be statistically significant and this new, inexpensive, marker-less, non-invasive, easy to set up, gait analysis system offers a readable and flexible tool for clinicians to analyze gait characteristics and to provide a fast diagnostic. This system, which estimates a perceptual color map providing a quick overview of asymmetry existing in the gait cycle of a subject, can be easily exploited for disease progression, recovery cues from post-operative surgery (e.g., to check the healing process or the effect of a treatment or a prosthesis) or might be used for other pathologies where gait asymmetry might be a symptom.

  4. A Mobile Kalman-Filter Based Solution for the Real-Time Estimation of Spatio-Temporal Gait Parameters.

    PubMed

    Ferrari, Alberto; Ginis, Pieter; Hardegger, Michael; Casamassima, Filippo; Rocchi, Laura; Chiari, Lorenzo

    2016-07-01

    Gait impairments are among the most disabling symptoms in several musculoskeletal and neurological conditions, severely limiting personal autonomy. Wearable gait sensors have been attracting attention as diagnostic tool for gait and are emerging as promising tool for tutoring and guiding gait execution. If their popularity is continuously growing, still there is room for improvement, especially towards more accurate solutions for spatio-temporal gait parameters estimation. We present an implementation of a zero-velocity-update gait analysis system based on a Kalman filter and off-the-shelf shoe-worn inertial sensors. The algorithms for gait events and step length estimation were specifically designed to comply with pathological gait patterns. More so, an Android app was deployed to support fully wearable and stand-alone real-time gait analysis. Twelve healthy subjects were enrolled to preliminarily tune the algorithms; afterwards sixteen persons with Parkinson's disease were enrolled for a validation study. Over the 1314 strides collected on patients at three different speeds, the total root mean square difference on step length estimation between this system and a gold standard was 2.9%. This shows that the proposed method allows for an accurate gait analysis and paves the way to a new generation of mobile devices usable anywhere for monitoring and intervention.

  5. General tensor discriminant analysis and gabor features for gait recognition.

    PubMed

    Tao, Dacheng; Li, Xuelong; Wu, Xindong; Maybank, Stephen J

    2007-10-01

    The traditional image representations are not suited to conventional classification methods, such as the linear discriminant analysis (LDA), because of the under sample problem (USP): the dimensionality of the feature space is much higher than the number of training samples. Motivated by the successes of the two dimensional LDA (2DLDA) for face recognition, we develop a general tensor discriminant analysis (GTDA) as a preprocessing step for LDA. The benefits of GTDA compared with existing preprocessing methods, e.g., principal component analysis (PCA) and 2DLDA, include 1) the USP is reduced in subsequent classification by, for example, LDA; 2) the discriminative information in the training tensors is preserved; and 3) GTDA provides stable recognition rates because the alternating projection optimization algorithm to obtain a solution of GTDA converges, while that of 2DLDA does not. We use human gait recognition to validate the proposed GTDA. The averaged gait images are utilized for gait representation. Given the popularity of Gabor function based image decompositions for image understanding and object recognition, we develop three different Gabor function based image representations: 1) the GaborD representation is the sum of Gabor filter responses over directions, 2) GaborS is the sum of Gabor filter responses over scales, and 3) GaborSD is the sum of Gabor filter responses over scales and directions. The GaborD, GaborS and GaborSD representations are applied to the problem of recognizing people from their averaged gait images.A large number of experiments were carried out to evaluate the effectiveness (recognition rate) of gait recognition based on first obtaining a Gabor, GaborD, GaborS or GaborSD image representation, then using GDTA to extract features and finally using LDA for classification. The proposed methods achieved good performance for gait recognition based on image sequences from the USF HumanID Database. Experimental comparisons are made with nine state of the art classification methods in gait recognition.

  6. Detrended Fluctuation Analysis and Adaptive Fractal Analysis of Stride Time Data in Parkinson's Disease: Stitching Together Short Gait Trials

    PubMed Central

    Liebherr, Magnus; Haas, Christian T.

    2014-01-01

    Variability indicates motor control disturbances and is suitable to identify gait pathologies. It can be quantified by linear parameters (amplitude estimators) and more sophisticated nonlinear methods (structural information). Detrended Fluctuation Analysis (DFA) is one method to measure structural information, e.g., from stride time series. Recently, an improved method, Adaptive Fractal Analysis (AFA), has been proposed. This method has not been applied to gait data before. Fractal scaling methods (FS) require long stride-to-stride data to obtain valid results. However, in clinical studies, it is not usual to measure a large number of strides (e.g., strides). Amongst others, clinical gait analysis is limited due to short walkways, thus, FS seem to be inapplicable. The purpose of the present study was to evaluate FS under clinical conditions. Stride time data of five self-paced walking trials ( strides each) of subjects with PD and a healthy control group (CG) was measured. To generate longer time series, stride time sequences were stitched together. The coefficient of variation (CV), fractal scaling exponents (DFA) and (AFA) were calculated. Two surrogate tests were performed: A) the whole time series was randomly shuffled; B) the single trials were randomly shuffled separately and afterwards stitched together. CV did not discriminate between PD and CG. However, significant differences between PD and CG were found concerning and . Surrogate version B yielded a higher mean squared error and empirical quantiles than version A. Hence, we conclude that the stitching procedure creates an artificial structure resulting in an overestimation of true . The method of stitching together sections of gait seems to be appropriate in order to distinguish between PD and CG with FS. It provides an approach to integrate FS as standard in clinical gait analysis and to overcome limitations such as short walkways. PMID:24465708

  7. Joint kinematic calculation based on clinical direct kinematic versus inverse kinematic gait models.

    PubMed

    Kainz, H; Modenese, L; Lloyd, D G; Maine, S; Walsh, H P J; Carty, C P

    2016-06-14

    Most clinical gait laboratories use the conventional gait analysis model. This model uses a computational method called Direct Kinematics (DK) to calculate joint kinematics. In contrast, musculoskeletal modelling approaches use Inverse Kinematics (IK) to obtain joint angles. IK allows additional analysis (e.g. muscle-tendon length estimates), which may provide valuable information for clinical decision-making in people with movement disorders. The twofold aims of the current study were: (1) to compare joint kinematics obtained by a clinical DK model (Vicon Plug-in-Gait) with those produced by a widely used IK model (available with the OpenSim distribution), and (2) to evaluate the difference in joint kinematics that can be solely attributed to the different computational methods (DK versus IK), anatomical models and marker sets by using MRI based models. Eight children with cerebral palsy were recruited and presented for gait and MRI data collection sessions. Differences in joint kinematics up to 13° were found between the Plug-in-Gait and the gait 2392 OpenSim model. The majority of these differences (94.4%) were attributed to differences in the anatomical models, which included different anatomical segment frames and joint constraints. Different computational methods (DK versus IK) were responsible for only 2.7% of the differences. We recommend using the same anatomical model for kinematic and musculoskeletal analysis to ensure consistency between the obtained joint angles and musculoskeletal estimates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Effects of gyrokinesis exercise on the gait pattern of female patients with chronic low back pain

    PubMed Central

    Seo, Kook-Eun; Park, Tae-Jin

    2016-01-01

    [Purpose] The purpose of the present study was to use kinematic variables to identify the effects of 8/weeks’ performance of a gyrokinesis exercise on the gait pattern of females with chronic low back pain. [Subjects] The subjects of the present study were females in their late 20s to mid 30s who were chronic back pain patients. [Methods] A 3-D motion analysis system was used to measure the changes in their gait patterns between pre and post-gyrokintic exercise. The SPSS 21.0 statistics program was used to perform the paired t-test, to compare the gait patterns of pre-post-gyrokinesis exercise. [Results] In the gait analysis, pre-post-gyrokinesis exercise gait patterns showed statistically significant differences in right and left step length, stride length, right-left step widths, and stride speed. [Conclusion] Gait pattern analysis revealed increases in step length, stride length, and stride speed along with a decrease in step width after 8 weeks of gyrokinesis exercise, demonstrating it improved gait pattern. PMID:27065537

  9. Trunk lean gait decreases multi-segmental coordination in the vertical direction.

    PubMed

    Tokuda, Kazuki; Anan, Masaya; Sawada, Tomonori; Tanimoto, Kenji; Takeda, Takuya; Ogata, Yuta; Takahashi, Makoto; Kito, Nobuhiro; Shinkoda, Koichi

    2017-11-01

    [Purpose] The strategy of trunk lean gait to reduce external knee adduction moment (KAM) may affect multi-segmental synergy control of center of mass (COM) displacement. Uncontrolled manifold (UCM) analysis is an evaluation index to understand motor variability. The purpose of this study was to investigate how motor variability is affected by using UCM analysis on adjustment of the trunk lean angle. [Subjects and Methods] Fifteen healthy young adults walked at their preferred speed under two conditions: normal and trunk lean gait. UCM analysis was performed with respect to the COM displacement during the stance phase. The KAM data were analyzed at the points of the first KAM peak during the stance phase. [Results] The KAM during trunk lean gait was smaller than during normal gait. Despite a greater segmental configuration variance with respect to mediolateral COM displacement during trunk lean gait, the synergy index was not significantly different between the two conditions. The synergy index with respect to vertical COM displacement during trunk lean gait was smaller than that during normal gait. [Conclusion] These results suggest that trunk lean gait is effective in reducing KAM; however, it may decrease multi-segmental movement coordination of COM control in the vertical direction.

  10. Reliability of videotaped observational gait analysis in patients with orthopedic impairments

    PubMed Central

    Brunnekreef, Jaap J; van Uden, Caro JT; van Moorsel, Steven; Kooloos, Jan GM

    2005-01-01

    Background In clinical practice, visual gait observation is often used to determine gait disorders and to evaluate treatment. Several reliability studies on observational gait analysis have been described in the literature and generally showed moderate reliability. However, patients with orthopedic disorders have received little attention. The objective of this study is to determine the reliability levels of visual observation of gait in patients with orthopedic disorders. Methods The gait of thirty patients referred to a physical therapist for gait treatment was videotaped. Ten raters, 4 experienced, 4 inexperienced and 2 experts, individually evaluated these videotaped gait patterns of the patients twice, by using a structured gait analysis form. Reliability levels were established by calculating the Intraclass Correlation Coefficient (ICC), using a two-way random design and based on absolute agreement. Results The inter-rater reliability among experienced raters (ICC = 0.42; 95%CI: 0.38–0.46) was comparable to that of the inexperienced raters (ICC = 0.40; 95%CI: 0.36–0.44). The expert raters reached a higher inter-rater reliability level (ICC = 0.54; 95%CI: 0.48–0.60). The average intra-rater reliability of the experienced raters was 0.63 (ICCs ranging from 0.57 to 0.70). The inexperienced raters reached an average intra-rater reliability of 0.57 (ICCs ranging from 0.52 to 0.62). The two expert raters attained ICC values of 0.70 and 0.74 respectively. Conclusion Structured visual gait observation by use of a gait analysis form as described in this study was found to be moderately reliable. Clinical experience appears to increase the reliability of visual gait analysis. PMID:15774012

  11. An IMU-to-Body Alignment Method Applied to Human Gait Analysis.

    PubMed

    Vargas-Valencia, Laura Susana; Elias, Arlindo; Rocon, Eduardo; Bastos-Filho, Teodiano; Frizera, Anselmo

    2016-12-10

    This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis.

  12. Automated extraction and validation of children's gait parameters with the Kinect.

    PubMed

    Motiian, Saeid; Pergami, Paola; Guffey, Keegan; Mancinelli, Corrie A; Doretto, Gianfranco

    2015-12-02

    Gait analysis for therapy regimen prescription and monitoring requires patients to physically access clinics with specialized equipment. The timely availability of such infrastructure at the right frequency is especially important for small children. Besides being very costly, this is a challenge for many children living in rural areas. This is why this work develops a low-cost, portable, and automated approach for in-home gait analysis, based on the Microsoft Kinect. A robust and efficient method for extracting gait parameters is introduced, which copes with the high variability of noisy Kinect skeleton tracking data experienced across the population of young children. This is achieved by temporally segmenting the data with an approach based on coupling a probabilistic matching of stride template models, learned offline, with the estimation of their global and local temporal scaling. A preliminary study conducted on healthy children between 2 and 4 years of age is performed to analyze the accuracy, precision, repeatability, and concurrent validity of the proposed method against the GAITRite when measuring several spatial and temporal children's gait parameters. The method has excellent accuracy and good precision, with segmenting temporal sequences of body joint locations into stride and step cycles. Also, the spatial and temporal gait parameters, estimated automatically, exhibit good concurrent validity with those provided by the GAITRite, as well as very good repeatability. In particular, on a range of nine gait parameters, the relative and absolute agreements were found to be good and excellent, and the overall agreements were found to be good and moderate. This work enables and validates the automated use of the Kinect for children's gait analysis in healthy subjects. In particular, the approach makes a step forward towards developing a low-cost, portable, parent-operated in-home tool for clinicians assisting young children.

  13. Gait characteristics under different walking conditions: Association with the presence of cognitive impairment in community-dwelling older people

    PubMed Central

    Fransen, Erik; Perkisas, Stany; Verhoeven, Veronique; Beauchet, Olivier; Remmen, Roy

    2017-01-01

    Background Gait characteristics measured at usual pace may allow profiling in patients with cognitive problems. The influence of age, gender, leg length, modified speed or dual tasking is unclear. Methods Cross-sectional analysis was performed on a data registry containing demographic, physical and spatial-temporal gait parameters recorded in five walking conditions with a GAITRite® electronic carpet in community-dwelling older persons with memory complaints. Four cognitive stages were studied: cognitively healthy individuals, mild cognitive impaired patients, mild dementia patients and advanced dementia patients. Results The association between spatial-temporal gait characteristics and cognitive stages was the most prominent: in the entire study population using gait speed, steps per meter (translation for mean step length), swing time variability, normalised gait speed (corrected for leg length) and normalised steps per meter at all five walking conditions; in the 50-to-70 years old participants applying step width at fast pace and steps per meter at usual pace; in the 70-to-80 years old persons using gait speed and normalised gait speed at usual pace, fast pace, animal walk and counting walk or steps per meter and normalised steps per meter at all five walking conditions; in over-80 years old participants using gait speed, normalised gait speed, steps per meter and normalised steps per meter at fast pace and animal dual-task walking. Multivariable logistic regression analysis adjusted for gender predicted in two compiled models the presence of dementia or cognitive impairment with acceptable accuracy in persons with memory complaints. Conclusion Gait parameters in multiple walking conditions adjusted for age, gender and leg length showed a significant association with cognitive impairment. This study suggested that multifactorial gait analysis could be more informative than using gait analysis with only one test or one variable. Using this type of gait analysis in clinical practice could facilitate screening for cognitive impairment. PMID:28570662

  14. The interest of gait markers in the identification of subgroups among fibromyalgia patients

    PubMed Central

    2011-01-01

    Background Fibromyalgia (FM) is a heterogeneous syndrome and its classification into subgroups calls for broad-based discussion. FM subgrouping, which aims to adapt treatment according to different subgroups, relies in part, on psychological and cognitive dysfunctions. Since motor control of gait is closely related to cognitive function, we hypothesized that gait markers could be of interest in the identification of FM patients' subgroups. This controlled study aimed at characterizing gait disorders in FM, and subgrouping FM patients according to gait markers such as stride frequency (SF), stride regularity (SR), and cranio-caudal power (CCP) which measures kinesia. Methods A multicentre, observational open trial enrolled patients with primary FM (44.1 ± 8.1 y), and matched controls (44.1 ± 7.3 y). Outcome measurements and gait analyses were available for 52 pairs. A 3-step statistical analysis was carried out. A preliminary single blind analysis using k-means cluster was performed as an initial validation of gait markers. Then in order to quantify FM patients according to psychometric and gait variables an open descriptive analysis comparing patients and controls were made, and correlations between gait variables and main outcomes were calculated. Finally using cluster analysis, we described subgroups for each gait variable and looked for significant differences in self-reported assessments. Results SF was the most discriminating gait variable (73% of patients and controls). SF, SR, and CCP were different between patients and controls. There was a non-significant association between SF, FIQ and physical components from Short-Form 36 (p = 0.06). SR was correlated to FIQ (p = 0.01) and catastrophizing (p = 0.05) while CCP was correlated to pain (p = 0.01). The SF cluster identified 3 subgroups with a particular one characterized by normal SF, low pain, high activity and hyperkinesia. The SR cluster identified 2 distinct subgroups: the one with a reduced SR was distinguished by high FIQ, poor coping and altered affective status. Conclusion Gait analysis may provide additional information in the identification of subgroups among fibromyalgia patients. Gait analysis provided relevant information about physical and cognitive status, and pain behavior. Further studies are needed to better understand gait analysis implications in FM. PMID:22078002

  15. Video gait analysis for ambulatory children with cerebral palsy: Why, when, where and how!

    PubMed

    Harvey, Adrienne; Gorter, Jan Willem

    2011-03-01

    This paper outlines the application of video gait analysis (VGA) for children with cerebral palsy (CP) when full instrumented three dimensional gait analysis (3DGA) is either not indicated or not available. Gait analysis is an important part of the assessment of ambulant children with CP for diagnosing gait deviations and for evaluating change. Many regard 3DGA as the most informative method of assessing gait, however, it is not always accessible, practical, or feasible and the detail obtained is not always indicated. VGA in conjunction with other carefully selected outcome measures can provide a comprehensive gait assessment in situations where 3DGA is not available or not indicated. Indications for VGA use include: documenting change in gait pattern over time, frequent monitoring in the rehabilitation phase following treatments and interventions (including surgery, spasticity management, serial casting and intensive therapy), monitoring orthotic changes, and for very young children and those with behavioural/cognitive issues that preclude them from cooperating with a 3DGA. Simple and inexpensive VGA systems can be set up in most settings. In an effort to make the process more objective and reliable a number of observational gait scales have been developed. Of these the Edinburgh Gait Score (EGS) has the strongest psychometric properties and is the most comprehensive by including both the coronal and the sagittal planes. While 3DGA remains an important part of complex clinical decision-making, there is also an increasingly important role for VGA. Guidelines need to be developed for its use within the field of gait analysis. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.

  16. Kinetic and kinematic follow‐up gait analysis in Doberman Pinschers with cervical spondylomyelopathy treated medically and surgically

    PubMed Central

    Smith, Rebecca L.; da Costa, Ronaldo C.

    2018-01-01

    Background The efficacy of treatment of dogs with cervical spondylomyelopathy (CSM) is commonly based on the owner's and clinician's perception of the gait, which is highly subjective and suffers from observer bias. Hypothesis/Objectives To compare selected kinetic and kinematic parameters before and after treatments and to correlate the findings of gait analysis to clinical outcome. Animals Eight Doberman Pinschers with CSM confirmed by magnetic resonsance imaging. Methods Patients were prospectively studied and treated with either medical management (n = 5) or surgery (n = 3). Force plate analysis and 3‐D kinematic motion capture were performed at initial presentation and approximately 8 weeks later. Force plate parameters evaluated included peak vertical force (PVF). Kinematic parameters measured included number of pelvic limb strides, stifle flexion and extension, maximum and minimum thoracic limb distance, truncal sway, and thoracic limb stride duration. Results Kinematic analysis showed that deviation of the spine to the right (truncal sway) was significantly smaller (P < .001) and the degree of right stifle flexion was significantly larger (P = .029) after treatment. Force plate analysis indicated that PVF was significantly different after treatment (P = .049) and the difference of the PVF also was significantly larger (P = .027). However, no correlation was found with either method of gait analysis and clinical recovery. Conclusions and Clinical Importance Kinetic and kinematic gait analysis were able to detect differences in dogs with CSM before and after treatment. A correlation of gait analysis to clinical improvement could not be determined. PMID:29572944

  17. Guidelines for Assessment of Gait and Reference Values for Spatiotemporal Gait Parameters in Older Adults: The Biomathics and Canadian Gait Consortiums Initiative

    PubMed Central

    Beauchet, Olivier; Allali, Gilles; Sekhon, Harmehr; Verghese, Joe; Guilain, Sylvie; Steinmetz, Jean-Paul; Kressig, Reto W.; Barden, John M.; Szturm, Tony; Launay, Cyrille P.; Grenier, Sébastien; Bherer, Louis; Liu-Ambrose, Teresa; Chester, Vicky L.; Callisaya, Michele L.; Srikanth, Velandai; Léonard, Guillaume; De Cock, Anne-Marie; Sawa, Ryuichi; Duque, Gustavo; Camicioli, Richard; Helbostad, Jorunn L.

    2017-01-01

    Background: Gait disorders, a highly prevalent condition in older adults, are associated with several adverse health consequences. Gait analysis allows qualitative and quantitative assessments of gait that improves the understanding of mechanisms of gait disorders and the choice of interventions. This manuscript aims (1) to give consensus guidance for clinical and spatiotemporal gait analysis based on the recorded footfalls in older adults aged 65 years and over, and (2) to provide reference values for spatiotemporal gait parameters based on the recorded footfalls in healthy older adults free of cognitive impairment and multi-morbidities. Methods: International experts working in a network of two different consortiums (i.e., Biomathics and Canadian Gait Consortium) participated in this initiative. First, they identified items of standardized information following the usual procedure of formulation of consensus findings. Second, they merged databases including spatiotemporal gait assessments with GAITRite® system and clinical information from the “Gait, cOgnitiOn & Decline” (GOOD) initiative and the Generation 100 (Gen 100) study. Only healthy—free of cognitive impairment and multi-morbidities (i.e., ≤ 3 therapeutics taken daily)—participants aged 65 and older were selected. Age, sex, body mass index, mean values, and coefficients of variation (CoV) of gait parameters were used for the analyses. Results: Standardized systematic assessment of three categories of items, which were demographics and clinical information, and gait characteristics (clinical and spatiotemporal gait analysis based on the recorded footfalls), were selected for the proposed guidelines. Two complementary sets of items were distinguished: a minimal data set and a full data set. In addition, a total of 954 participants (mean age 72.8 ± 4.8 years, 45.8% women) were recruited to establish the reference values. Performance of spatiotemporal gait parameters based on the recorded footfalls declined with increasing age (mean values and CoV) and demonstrated sex differences (mean values). Conclusions: Based on an international multicenter collaboration, we propose consensus guidelines for gait assessment and spatiotemporal gait analysis based on the recorded footfalls, and reference values for healthy older adults. PMID:28824393

  18. A New Classification of Diabetic Gait Pattern Based on Cluster Analysis of Biomechanical Data

    PubMed Central

    Sawacha, Zimi; Guarneri, Gabriella; Avogaro, Angelo; Cobelli, Claudio

    2010-01-01

    Background The diabetic foot, one of the most serious complications of diabetes mellitus and a major risk factor for plantar ulceration, is determined mainly by peripheral neuropathy. Neuropathic patients exhibit decreased stability while standing as well as during dynamic conditions. A new methodology for diabetic gait pattern classification based on cluster analysis has been proposed that aims to identify groups of subjects with similar patterns of gait and verify if three-dimensional gait data are able to distinguish diabetic gait patterns from one of the control subjects. Method The gait of 20 nondiabetic individuals and 46 diabetes patients with and without peripheral neuropathy was analyzed [mean age 59.0 (2.9) and 61.1(4.4) years, mean body mass index (BMI) 24.0 (2.8), and 26.3 (2.0)]. K-means cluster analysis was applied to classify the subjects' gait patterns through the analysis of their ground reaction forces, joints and segments (trunk, hip, knee, ankle) angles, and moments. Results Cluster analysis classification led to definition of four well-separated clusters: one aggregating just neuropathic subjects, one aggregating both neuropathics and non-neuropathics, one including only diabetes patients, and one including either controls or diabetic and neuropathic subjects. Conclusions Cluster analysis was useful in grouping subjects with similar gait patterns and provided evidence that there were subgroups that might otherwise not be observed if a group ensemble was presented for any specific variable. In particular, we observed the presence of neuropathic subjects with a gait similar to the controls and diabetes patients with a long disease duration with a gait as altered as the neuropathic one. PMID:20920432

  19. The development of a tool for assessing the quality of closed circuit camera footage for use in forensic gait analysis.

    PubMed

    Birch, Ivan; Vernon, Wesley; Walker, Jeremy; Saxelby, Jai

    2013-10-01

    Gait analysis from closed circuit camera footage is now commonly used as evidence in criminal trials. The biomechanical analysis of human gait is a well established science in both clinical and laboratory settings. However, closed circuit camera footage is rarely of the quality of that taken in the more controlled clinical and laboratory environments. The less than ideal quality of much of this footage for use in gait analysis is associated with a range of issues, the combination of which can often render the footage unsuitable for use in gait analysis. The aim of this piece of work was to develop a tool for assessing the suitability of closed circuit camera footage for the purpose of forensic gait analysis. A Delphi technique was employed with a small sample of expert forensic gait analysis practitioners, to identify key quality elements of CCTV footage used in legal proceedings. Five elements of the footage were identified and then subdivided into 15 contributing sub-elements, each of which was scored using a 5-point Likert scale. A Microsoft Excel worksheet was developed to calculate automatically an overall score from the fifteen sub-element scores. Five expert witnesses experienced in using CCTV footage for gait analysis then trialled the prototype tool on current case footage. A repeatability study was also undertaken using standardized CCTV footage. The results showed the tool to be a simple and repeatable means of assessing the suitability of closed circuit camera footage for use in forensic gait analysis. The inappropriate use of poor quality footage could lead to challenges to the practice of forensic gait analysis. All parties involved in criminal proceedings must therefore understand the fitness for purpose of any footage used. The development of this tool could offer a method of achieving this goal, and help to assure the continued role of forensic gait analysis as an aid to the identification process. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  20. Gait Profile Score in multiple sclerosis patients with low disability.

    PubMed

    Morel, Eric; Allali, Gilles; Laidet, Magali; Assal, Frédéric; Lalive, Patrice H; Armand, Stéphane

    2017-01-01

    Gait abnormalities are subtle in multiple sclerosis (MS) patients with low disability and need to be better determined. As a biomechanical approach, the Gait Profile Score (GPS) is used to assess gait quality by combining nine gait kinematic variables in one single value. This study aims i) to establish if the GPS can detect gait impairments and ii) to compare GPS with discrete spatiotemporal and kinematic parameters in low-disabled MS patients. Thirty-four relapsing-remitting MS patients with an Expanded Disability Status Scale (EDSS) score ≤2 (mean age 36.32±8.72 years; 12 men, 22 women; mean EDSS 1.19±0.8) and twenty-two healthy controls (mean age 36.85±7.87 years; 6 men, 16 women) matched for age, weight, height, body mass index and gender underwent an instrumented gait analysis. No significant difference in GPS values and in spatiotemporal parameters was found between patients and controls. However patients showed a significant alteration at the ankle and pelvis level. GPS fails to identify gait abnormalities in low-disabled MS patients, although kinematic analysis revealed subtle gait alterations. Future studies should investigate other methods to assess gait impairments with a gait score in low-disabled MS patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Modeling and simulation of normal and hemiparetic gait

    NASA Astrophysics Data System (ADS)

    Luengas, Lely A.; Camargo, Esperanza; Sanchez, Giovanni

    2015-09-01

    Gait is the collective term for the two types of bipedal locomotion, walking and running. This paper is focused on walking. The analysis of human gait is of interest to many different disciplines, including biomechanics, human-movement science, rehabilitation and medicine in general. Here we present a new model that is capable of reproducing the properties of walking, normal and pathological. The aim of this paper is to establish the biomechanical principles that underlie human walking by using Lagrange method. The constraint forces of Rayleigh dissipation function, through which to consider the effect on the tissues in the gait, are included. Depending on the value of the factor present in the Rayleigh dissipation function, both normal and pathological gait can be simulated. First of all, we apply it in the normal gait and then in the permanent hemiparetic gait. Anthropometric data of adult person are used by simulation, and it is possible to use anthropometric data for children but is necessary to consider existing table of anthropometric data. Validation of these models includes simulations of passive dynamic gait that walk on level ground. The dynamic walking approach provides a new perspective of gait analysis, focusing on the kinematics and kinetics of gait. There have been studies and simulations to show normal human gait, but few of them have focused on abnormal, especially hemiparetic gait. Quantitative comparisons of the model predictions with gait measurements show that the model can reproduce the significant characteristics of normal gait.

  2. An IMU-to-Body Alignment Method Applied to Human Gait Analysis

    PubMed Central

    Vargas-Valencia, Laura Susana; Elias, Arlindo; Rocon, Eduardo; Bastos-Filho, Teodiano; Frizera, Anselmo

    2016-01-01

    This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis. PMID:27973406

  3. Gait profile score and movement analysis profile in patients with Parkinson's disease during concurrent cognitive load

    PubMed Central

    Speciali, Danielli S.; Oliveira, Elaine M.; Cardoso, Jefferson R.; Correa, João C. F.; Baker, Richard; Lucareli, Paulo R. G.

    2014-01-01

    Background: Gait disorders are common in individuals with Parkinson's Disease (PD) and the concurrent performance of motor and cognitive tasks can have marked effects on gait. The Gait Profile Score (GPS) and the Movement Analysis Profile (MAP) were developed in order to summarize the data of kinematics and facilitate understanding of the results of gait analysis. Objective: To investigate the effectiveness of the GPS and MAP in the quantification of changes in gait during a concurrent cognitive load while walking in adults with and without PD. Method: Fourteen patients with idiopathic PD and nine healthy subjects participated in the study. All subjects performed single and dual walking tasks. The GPS/MAP was computed from three-dimensional gait analysis data. Results: Differences were found between tasks for GPS (P<0.05) and Gait Variable Score (GVS) (pelvic rotation, knee flexion-extension and ankle dorsiflexion-plantarflexion) (P<0.05) in the PD group. An interaction between task and group was observed for GPS (P<0.01) for the right side (Cohen's ¯d=0.99), left side (Cohen's ¯d=0.91), and overall (Cohen's ¯d=0.88). No interaction was observed only for hip internal-external rotation and foot internal-external progression GVS variables in the PD group. Conclusions: The results showed gait impairment during the dual task and suggest that GPS/MAP may be used to evaluate the effects of concurrent cognitive load while walking in patients with PD. PMID:25054382

  4. Low Power Shoe Integrated Intelligent Wireless Gait Measurement System

    NASA Astrophysics Data System (ADS)

    Wahab, Y.; Mazalan, M.; Bakar, N. A.; Anuar, A. F.; Zainol, M. Z.; Hamzah, F.

    2014-04-01

    Gait analysis measurement is a method to assess and identify gait events and the measurements of dynamic, motion and pressure parameters involving the lowest part of the body. This significant analysis is widely used in sports, rehabilitation as well as other health diagnostic towards improving the quality of life. This paper presents a new system empowered by Inertia Measurement Unit (IMU), ultrasonic sensors, piezoceramic sensors array, XBee wireless modules and Arduino processing unit. This research focuses on the design and development of a low power ultra-portable shoe integrated wireless intelligent gait measurement using MEMS and recent microelectronic devices for foot clearance, orientation, error correction, gait events and pressure measurement system. It is developed to be cheap, low power, wireless, real time and suitable for real life in-door and out-door environment.

  5. A systematic review of gait analysis methods based on inertial sensors and adaptive algorithms.

    PubMed

    Caldas, Rafael; Mundt, Marion; Potthast, Wolfgang; Buarque de Lima Neto, Fernando; Markert, Bernd

    2017-09-01

    The conventional methods to assess human gait are either expensive or complex to be applied regularly in clinical practice. To reduce the cost and simplify the evaluation, inertial sensors and adaptive algorithms have been utilized, respectively. This paper aims to summarize studies that applied adaptive also called artificial intelligence (AI) algorithms to gait analysis based on inertial sensor data, verifying if they can support the clinical evaluation. Articles were identified through searches of the main databases, which were encompassed from 1968 to October 2016. We have identified 22 studies that met the inclusion criteria. The included papers were analyzed due to their data acquisition and processing methods with specific questionnaires. Concerning the data acquisition, the mean score is 6.1±1.62, what implies that 13 of 22 papers failed to report relevant outcomes. The quality assessment of AI algorithms presents an above-average rating (8.2±1.84). Therefore, AI algorithms seem to be able to support gait analysis based on inertial sensor data. Further research, however, is necessary to enhance and standardize the application in patients, since most of the studies used distinct methods to evaluate healthy subjects. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Fear of falling and gait variability in older adults: a systematic review and meta-analysis.

    PubMed

    Ayoubi, Farah; Launay, Cyrille P; Annweiler, Cédric; Beauchet, Olivier

    2015-01-01

    Fear of falling (FOF) and increased gait variability are both independent markers of gait instability. There is a complex interplay between both entities. The purposes of this study were (1) to perform a qualitative analysis of all published studies on FOF-related changes in gait variability through a systematic review, and (2) to quantitatively synthesize FOF-related changes in gait variability. A systematic Medline literature search was conducted in May 2014 using the Medical Subject Heading (MeSH) terms "Fear" OR "fear of falling" combined with "Accidental Falls" AND "Gait" OR "Gait Apraxia" OR "Gait Ataxia" OR "Gait disorders, Neurologic" OR "Gait assessment" OR "Functional gait assessment" AND "Self efficacy" OR "Self confidence" AND "Aged" OR "Aged, 80 and over." Systematic review and fixed-effects meta-analysis using an inverse-variance method were performed. Of the 2184 selected studies, 10 observational studies (including 5 cross-sectional studies, 4 prospective cohort studies, and 1 case-control study) met the selection criteria. All were of good quality. The number of participants ranged from 52 to 1307 older community-dwellers (26.2%-85.0% women). The meta-analysis was performed on 10 studies with a total of 999 cases and 4502 controls. In one study, the higher limits of the effect size's confidence interval (CI) were lower than zero. In the remaining studies, the higher limits of the CI were positive. The summary random effect size of 0.29 (95% CI 0.13-0.45) was significant albeit of small magnitude, and indicated that gait variability was overall 0.29 SD higher in FOF cases compared with controls. Our findings show that FOF is associated with a statistically significant, albeit of small magnitude, increase in gait variability. Copyright © 2015 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  7. Automated quantitative gait analysis during overground locomotion in the rat: its application to spinal cord contusion and transection injuries.

    PubMed

    Hamers, F P; Lankhorst, A J; van Laar, T J; Veldhuis, W B; Gispen, W H

    2001-02-01

    Analysis of locomotion is an important tool in the study of peripheral and central nervous system damage. Most locomotor scoring systems in rodents are based either upon open field locomotion assessment, for example, the BBB score or upon foot print analysis. The former yields a semiquantitative description of locomotion as a whole, whereas the latter generates quantitative data on several selected gait parameters. In this paper, we describe the use of a newly developed gait analysis method that allows easy quantitation of a large number of locomotion parameters during walkway crossing. We were able to extract data on interlimb coordination, swing duration, paw print areas (total over stance, and at 20-msec time resolution), stride length, and base of support: Similar data can not be gathered by any single previously described method. We compare changes in gait parameters induced by two different models of spinal cord injury in rats, transection of the dorsal half of the spinal cord and spinal cord contusion injury induced by the NYU or MASCIS device. Although we applied this method to rats with spinal cord injury, the usefulness of this method is not limited to rats or to the investigation of spinal cord injuries alone.

  8. Markerless identification of key events in gait cycle using image flow.

    PubMed

    Vishnoi, Nalini; Duric, Zoran; Gerber, Naomi Lynn

    2012-01-01

    Gait analysis has been an interesting area of research for several decades. In this paper, we propose image-flow-based methods to compute the motion and velocities of different body segments automatically, using a single inexpensive video camera. We then identify and extract different events of the gait cycle (double-support, mid-swing, toe-off and heel-strike) from video images. Experiments were conducted in which four walking subjects were captured from the sagittal plane. Automatic segmentation was performed to isolate the moving body from the background. The head excursion and the shank motion were then computed to identify the key frames corresponding to different events in the gait cycle. Our approach does not require calibrated cameras or special markers to capture movement. We have also compared our method with the Optotrak 3D motion capture system and found our results in good agreement with the Optotrak results. The development of our method has potential use in the markerless and unencumbered video capture of human locomotion. Monitoring gait in homes and communities provides a useful application for the aged and the disabled. Our method could potentially be used as an assessment tool to determine gait symmetry or to establish the normal gait pattern of an individual.

  9. Lack of maintenance of gait pattern as measured by instrumental methods suggests psychogenic gait.

    PubMed

    Merello, Marcelo; Ballesteros, Diego; Rossi, Malco; Arena, Julieta; Crespo, Marcos; Cervio, Andres; Cuello Oderiz, Carolina; Rivero, Alberto; Cerquetti, Daniel; Risk, Marcelo; Balej, Jorge

    2012-01-01

    Fluctuation is a common feature of all psychogenic gait disorder (PGD) patterns. Whether this fluctuation involves only the degree of impairment or whether it affects the gait pattern itself remains an interesting question. We hypothesize that, on repeated measurements, both normal and abnormal gait may present quantitative differences while maintaining their basic underlying pattern; conversely, in psychogenic gait, the basic pattern appears not to be preserved. Using an optoelectronic system, data acquired from 19 normal subjects and 66 patients were applied to train a neural network (NN) and subsequently classify gait patterns into four different groups (normal, ataxic, spastic-paraparetic and parkinsonian). Five patients who fulfilled clinical criteria for psychogenic gait and six controls were then prospectively evaluated on two separate occasions, three months apart. Normal controls and ataxic, parkinsonian or spastic patients were correctly identified by the NN, and categorized within the corresponding groups at baseline as well as at a three-month follow-up evaluation. NN analysis showed that after three months, no PGD patient preserved the gait pattern detected at baseline, even though this finding was not clinically apparent. Modification of gait pattern detected by repeated kinematic measurement and NN analysis could suggest the presence of PGD, particularly in difficult-to-diagnose cases.

  10. Systematic review of quantitative clinical gait analysis in patients with dementia.

    PubMed

    van Iersel, M B; Hoefsloot, W; Munneke, M; Bloem, B R; Olde Rikkert, M G M

    2004-02-01

    Diminished mobility often accompanies dementia and has a great impact on independence and quality of life. New treatment strategies for dementia are emerging, but the effects on gait remains to be studied objectively. In this review we address the general effects of dementia on gait as revealed by quantitative gait analysis. A systematic literature search with the (MESH) terms: 'dementia' and 'gait disorders' in Medline, CC, Psychlit and CinaHL between 1980-2002. Main inclusion criteria: controlled studies; patients with dementia; quantitative gait data. Seven publications met the inclusion criteria. All compared gait in Alzheimer's Disease (AD) with healthy elderly controls; one also assessed gait in Vascular Dementia (VaD). The methodology used was inconsistent and often had many shortcomings. However, there were several consistent findings: walking velocity decreased in dementia compared to healthy controls and decreased further with progressing severity of dementia. VaD was associated with a significant decrease in walking velocity compared to AD subjects. Dementia was associated with a shortened step length, an increased double support time and step to step variability. Gait in dementia is hardly analyzed in a well-designed manner. Despite this, the literature suggests that quantitative gait analysis can be sufficiently reliable and responsive to measure decline in walking velocity between subjects with and without dementia. More research is required to assess, both on an individual and a group level, how the minimal clinically relevant changes in gait in elderly demented patients should be defined and what would be the most responsive method to measure these changes.

  11. The Gait Deviation Index Is Associated with Hip Muscle Strength and Patient-Reported Outcome in Patients with Severe Hip Osteoarthritis—A Cross-Sectional Study

    PubMed Central

    Rosenlund, Signe; Holsgaard-Larsen, Anders; Overgaard, Søren; Jensen, Carsten

    2016-01-01

    Background The Gait Deviation Index summarizes overall gait ‘quality’, based on kinematic data from a 3-dimensional gait analysis. However, it is unknown which clinical outcomes may affect the Gait Deviation Index in patients with primary hip osteoarthritis. The aim of this study was to investigate associations between Gait Deviation Index as a measure of gait ‘quality’ and hip muscle strength and between Gait Deviation Index and patient-reported outcomes in patients with primary hip osteoarthritis. Method Forty-seven patients (34 males), aged 61.1 ± 6.7 years, with BMI 27.3 ± 3.4 (kg/m2) and with severe primary hip osteoarthritis underwent 3-dimensional gait analysis. Mean Gait Deviation Index, pain after walking and maximal isometric hip muscle strength (flexor, extensor, and abductor) were recorded. All patients completed the ‘Physical Function Short-form of the Hip disability and Osteoarthritis Outcome Score (HOOS-Physical Function) and the Hip disability and Osteoarthritis Outcome Score subscales for pain (HOOS-Pain) and quality-of-life (HOOS-QOL). Results Mean Gait Deviation Index was positively associated with hip abduction strength (p<0.01, r = 0.40), hip flexion strength (p = 0.01, r = 0.37), HOOS-Physical Function (p<0.01, r = 0.41) HOOS-QOL (p<0.01, r = 0.41), and negatively associated with HOOS-Pain after walking (p<0.01, r = -0.45). Adjusting the analysis for walking speed did not affect the association. Conclusion Patients with the strongest hip abductor and hip flexor muscles had the best gait ‘quality’. Furthermore, patients with higher physical function, quality of life scores and lower pain levels demonstrated better gait ‘quality’. These findings indicate that interventions aimed at improving hip muscle strength and pain management may to a moderate degree improve the overall gait ‘quality’ in patients with primary hip OA. PMID:27065007

  12. Gait recognition based on Gabor wavelets and modified gait energy image for human identification

    NASA Astrophysics Data System (ADS)

    Huang, Deng-Yuan; Lin, Ta-Wei; Hu, Wu-Chih; Cheng, Chih-Hsiang

    2013-10-01

    This paper proposes a method for recognizing human identity using gait features based on Gabor wavelets and modified gait energy images (GEIs). Identity recognition by gait generally involves gait representation, extraction, and classification. In this work, a modified GEI convolved with an ensemble of Gabor wavelets is proposed as a gait feature. Principal component analysis is then used to project the Gabor-wavelet-based gait features into a lower-dimension feature space for subsequent classification. Finally, support vector machine classifiers based on a radial basis function kernel are trained and utilized to recognize human identity. The major contributions of this paper are as follows: (1) the consideration of the shadow effect to yield a more complete segmentation of gait silhouettes; (2) the utilization of motion estimation to track people when walkers overlap; and (3) the derivation of modified GEIs to extract more useful gait information. Extensive performance evaluation shows a great improvement of recognition accuracy due to the use of shadow removal, motion estimation, and gait representation using the modified GEIs and Gabor wavelets.

  13. Class Energy Image Analysis for Video Sensor-Based Gait Recognition: A Review

    PubMed Central

    Lv, Zhuowen; Xing, Xianglei; Wang, Kejun; Guan, Donghai

    2015-01-01

    Gait is a unique perceptible biometric feature at larger distances, and the gait representation approach plays a key role in a video sensor-based gait recognition system. Class Energy Image is one of the most important gait representation methods based on appearance, which has received lots of attentions. In this paper, we reviewed the expressions and meanings of various Class Energy Image approaches, and analyzed the information in the Class Energy Images. Furthermore, the effectiveness and robustness of these approaches were compared on the benchmark gait databases. We outlined the research challenges and provided promising future directions for the field. To the best of our knowledge, this is the first review that focuses on Class Energy Image. It can provide a useful reference in the literature of video sensor-based gait representation approach. PMID:25574935

  14. Prediction of Knee Joint Contact Forces From External Measures Using Principal Component Prediction and Reconstruction.

    PubMed

    Saliba, Christopher M; Clouthier, Allison L; Brandon, Scott C E; Rainbow, Michael J; Deluzio, Kevin J

    2018-05-29

    Abnormal loading of the knee joint contributes to the pathogenesis of knee osteoarthritis. Gait retraining is a non-invasive intervention that aims to reduce knee loads by providing audible, visual, or haptic feedback of gait parameters. The computational expense of joint contact force prediction has limited real-time feedback to surrogate measures of the contact force, such as the knee adduction moment. We developed a method to predict knee joint contact forces using motion analysis and a statistical regression model that can be implemented in near real-time. Gait waveform variables were deconstructed using principal component analysis and a linear regression was used to predict the principal component scores of the contact force waveforms. Knee joint contact force waveforms were reconstructed using the predicted scores. We tested our method using a heterogenous population of asymptomatic controls and subjects with knee osteoarthritis. The reconstructed contact force waveforms had mean (SD) RMS differences of 0.17 (0.05) bodyweight compared to the contact forces predicted by a musculoskeletal model. Our method successfully predicted subject-specific shape features of contact force waveforms and is a potentially powerful tool in biofeedback and clinical gait analysis.

  15. Assessment of biofeedback rehabilitation in post-stroke patients combining fMRI and gait analysis: a case study

    PubMed Central

    2014-01-01

    Background The ability to walk independently is a primary goal for rehabilitation after stroke. Gait analysis provides a great amount of valuable information, while functional magnetic resonance imaging (fMRI) offers a powerful approach to define networks involved in motor control. The present study reports a new methodology based on both fMRI and gait analysis outcomes in order to investigate the ability of fMRI to reflect the phases of motor learning before/after electromyographic biofeedback treatment: the preliminary fMRI results of a post stroke subject’s brain activation, during passive and active ankle dorsal/plantarflexion, before and after biofeedback (BFB) rehabilitation are reported and their correlation with gait analysis data investigated. Methods A control subject and a post-stroke patient with chronic hemiparesis were studied. Functional magnetic resonance images were acquired during a block-design protocol on both subjects while performing passive and active ankle dorsal/plantarflexion. fMRI and gait analysis were assessed on the patient before and after electromyographic biofeedback rehabilitation treatment during gait activities. Lower limb three-dimensional kinematics, kinetics and surface electromyography were evaluated. Correlation between fMRI and gait analysis categorical variables was assessed: agreement/disagreement was assigned to each variable if the value was in/outside the normative range (gait analysis), or for presence of normal/diffuse/no activation of motor area (fMRI). Results Altered fMRI activity was found on the post-stroke patient before biofeedback rehabilitation with respect to the control one. Meanwhile the patient showed a diffuse, but more limited brain activation after treatment (less voxels). The post-stroke gait data showed a trend towards the normal range: speed, stride length, ankle power, and ankle positive work increased. Preliminary correlation analysis revealed that consistent changes were observed both for the fMRI data, and the gait analysis data after treatment (R > 0.89): this could be related to the possible effects BFB might have on the central as well as on the peripheral nervous system. Conclusions Our findings showed that this methodology allows evaluation of the relationship between alterations in gait and brain activation of a post-stroke patient. Such methodology, if applied on a larger sample subjects, could provide information about the specific motor area involved in a rehabilitation treatment. PMID:24716475

  16. Spatial parameters of walking gait and footedness.

    PubMed

    Zverev, Y P

    2006-01-01

    The present study was undertaken to assess whether footedness has effects on selected spatial and angular parameters of able-bodied gait by evaluating footprints of young adults. A total of 112 males and 93 females were selected from among students and staff members of the University of Malawi using a simple random sampling method. Footedness of subjects was assessed by the Waterloo Footedness Questionnaire Revised. Gait at natural speed was recorded using the footprint method. The following spatial parameters of gait were derived from the inked footprint sequences of subjects: step and stride lengths, gait angle and base of gait. The anthropometric measurements taken were weight, height, leg and foot length, foot breadth, shoulder width, and hip and waist circumferences. The prevalence of right-, left- and mix-footedness in the whole sample of young Malawian adults was 81%, 8.3% and 10.7%, respectively. One-way analysis of variance did not reveal a statistically significant difference between footedness categories in the mean values of anthropometric measurements (p > 0.05 for all variables). Gender differences in step and stride length values were not statistically significant. Correction of these variables for stature did not change the trend. Males had significantly broader steps than females. Normalized values of base of gait had similar gender difference. The group means of step length and normalized step length of the right and left feet were similar, for males and females. There was a significant side difference in the gait angle in both gender groups of volunteers with higher mean values on the left side compared to the right one (t = 2.64, p < 0.05 for males, and t = 2.78, p < 0.05 for females). One-way analysis of variance did not demonstrate significant difference between footedness categories in the mean values of step length, gait angle, bilateral differences in step length and gait angle, stride length, gait base and normalized gait variables of male and female volunteers (p > 0.05 for all variables). The present study demonstrated that footedness does not affect spatial and angular parameters of walking gait.

  17. Self-Tuning Threshold Method for Real-Time Gait Phase Detection Based on Ground Contact Forces Using FSRs.

    PubMed

    Tang, Jing; Zheng, Jianbin; Wang, Yang; Yu, Lie; Zhan, Enqi; Song, Qiuzhi

    2018-02-06

    This paper presents a novel methodology for detecting the gait phase of human walking on level ground. The previous threshold method (TM) sets a threshold to divide the ground contact forces (GCFs) into on-ground and off-ground states. However, the previous methods for gait phase detection demonstrate no adaptability to different people and different walking speeds. Therefore, this paper presents a self-tuning triple threshold algorithm (STTTA) that calculates adjustable thresholds to adapt to human walking. Two force sensitive resistors (FSRs) were placed on the ball and heel to measure GCFs. Three thresholds (i.e., high-threshold, middle-threshold andlow-threshold) were used to search out the maximum and minimum GCFs for the self-adjustments of thresholds. The high-threshold was the main threshold used to divide the GCFs into on-ground and off-ground statuses. Then, the gait phases were obtained through the gait phase detection algorithm (GPDA), which provides the rules that determine calculations for STTTA. Finally, the STTTA reliability is determined by comparing the results between STTTA and Mariani method referenced as the timing analysis module (TAM) and Lopez-Meyer methods. Experimental results show that the proposed method can be used to detect gait phases in real time and obtain high reliability when compared with the previous methods in the literature. In addition, the proposed method exhibits strong adaptability to different wearers walking at different walking speeds.

  18. Gender may have an influence on the relationship between Functional Movement Screen scores and gait parameters in elite junior athletes - A pilot study.

    PubMed

    Magyari, N; Szakács, V; Bartha, C; Szilágyi, B; Galamb, K; Magyar, M O; Hortobágyi, T; Kiss, R M; Tihanyi, J; Négyesi, J

    2017-09-01

    Aims The aim of this study was to examine the effects of gender on the relationship between Functional Movement Screen (FMS) and treadmill-based gait parameters. Methods Twenty elite junior athletes (10 women and 10 men) performed the FMS tests and gait analysis at a fixed speed. Between-gender differences were calculated for the relationship between FMS test scores and gait parameters, such as foot rotation, step length, and length of gait line. Results Gender did not affect the relationship between FMS and treadmill-based gait parameters. The nature of correlations between FMS test scores and gait parameters was different in women and men. Furthermore, different FMS test scores predicted different gait parameters in female and male athletes. FMS asymmetry and movement asymmetries measured by treadmill-based gait parameters did not correlate in either gender. Conclusion There were no interactions between FMS, gait parameters, and gender; however, correlation analyses support the idea that strength and conditioning coaches need to pay attention not only to how to score but also how to correctly use FMS.

  19. A Grassmann graph embedding framework for gait analysis

    NASA Astrophysics Data System (ADS)

    Connie, Tee; Goh, Michael Kah Ong; Teoh, Andrew Beng Jin

    2014-12-01

    Gait recognition is important in a wide range of monitoring and surveillance applications. Gait information has often been used as evidence when other biometrics is indiscernible in the surveillance footage. Building on recent advances of the subspace-based approaches, we consider the problem of gait recognition on the Grassmann manifold. We show that by embedding the manifold into reproducing kernel Hilbert space and applying the mechanics of graph embedding on such manifold, significant performance improvement can be obtained. In this work, the gait recognition problem is studied in a unified way applicable for both supervised and unsupervised configurations. Sparse representation is further incorporated in the learning mechanism to adaptively harness the local structure of the data. Experiments demonstrate that the proposed method can tolerate variations in appearance for gait identification effectively.

  20. Objective assessment of motor fatigue in multiple sclerosis using kinematic gait analysis: a pilot study

    PubMed Central

    2011-01-01

    Background Fatigue is a frequent and serious symptom in patients with Multiple Sclerosis (MS). However, to date there are only few methods for the objective assessment of fatigue. The aim of this study was to develop a method for the objective assessment of motor fatigue using kinematic gait analysis based on treadmill walking and an infrared-guided system. Patients and methods Fourteen patients with clinically definite MS participated in this study. Fatigue was defined according to the Fatigue Scale for Motor and Cognition (FSMC). Patients underwent a physical exertion test involving walking at their pre-determined patient-specific preferred walking speed until they reached complete exhaustion. Gait was recorded using a video camera, a three line-scanning camera system with 11 infrared sensors. Step length, width and height, maximum circumduction with the right and left leg, maximum knee flexion angle of the right and left leg, and trunk sway were measured and compared using paired t-tests (α = 0.005). In addition, variability in these parameters during one-minute intervals was examined. The fatigue index was defined as the number of significant mean and SD changes from the beginning to the end of the exertion test relative to the total number of gait kinematic parameters. Results Clearly, for some patients the mean gait parameters were more affected than the variability of their movements while other patients had smaller differences in mean gait parameters with greater increases in variability. Finally, for other patients gait changes with physical exertion manifested both in changes in mean gait parameters and in altered variability. The variability and fatigue indices correlated significantly with the motoric but not with the cognitive dimension of the FSMC score (R = -0.602 and R = -0.592, respectively; P < 0.026). Conclusions Changes in gait patterns following a physical exertion test in patients with MS suffering from motor fatigue can be measured objectively. These changes in gait patterns can be described using the motor fatigue index and represent an objective measure to assess motor fatigue in MS patients. The results of this study have important implications for the assessments and treatment evaluations of fatigue in MS. PMID:22029427

  1. Computer aided analysis of gait patterns in patients with acute anterior cruciate ligament injury.

    PubMed

    Christian, Josef; Kröll, Josef; Strutzenberger, Gerda; Alexander, Nathalie; Ofner, Michael; Schwameder, Hermann

    2016-03-01

    Gait analysis is a useful tool to evaluate the functional status of patients with anterior cruciate ligament injury. Pattern recognition methods can be used to automatically assess walking patterns and objectively support clinical decisions. This study aimed to test a pattern recognition system for analyzing kinematic gait patterns of recently anterior cruciate ligament injured patients and for evaluating the effects of a therapeutic treatment. Gait kinematics of seven male patients with an acute unilateral anterior cruciate ligament rupture and seven healthy males were recorded. A support vector machine was trained to distinguish the groups. Principal component analysis and recursive feature elimination were used to extract features from 3D marker trajectories. A Classifier Oriented Gait Score was defined as a measure of gait quality. Visualizations were used to allow functional interpretations of characteristic group differences. The injured group was evaluated by the system after a therapeutic treatment. The results were compared against a clinical rating of the patients' gait. Cross validation yielded 100% accuracy. After the treatment the score improved significantly (P<0.01) as well as the clinical rating (P<0.05). The visualizations revealed characteristic kinematic features, which differentiated between the groups. The results show that gait alterations in the early phase after anterior cruciate ligament injury can be detected automatically. The results of the automatic analysis are comparable with the clinical rating and support the validity of the system. The visualizations allow interpretations on discriminatory features and can facilitate the integration of the results into the diagnostic process. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Benchmarking Foot Trajectory Estimation Methods for Mobile Gait Analysis

    PubMed Central

    Ollenschläger, Malte; Roth, Nils; Klucken, Jochen

    2017-01-01

    Mobile gait analysis systems based on inertial sensing on the shoe are applied in a wide range of applications. Especially for medical applications, they can give new insights into motor impairment in, e.g., neurodegenerative disease and help objectify patient assessment. One key component in these systems is the reconstruction of the foot trajectories from inertial data. In literature, various methods for this task have been proposed. However, performance is evaluated on a variety of datasets due to the lack of large, generally accepted benchmark datasets. This hinders a fair comparison of methods. In this work, we implement three orientation estimation and three double integration schemes for use in a foot trajectory estimation pipeline. All methods are drawn from literature and evaluated against a marker-based motion capture reference. We provide a fair comparison on the same dataset consisting of 735 strides from 16 healthy subjects. As a result, the implemented methods are ranked and we identify the most suitable processing pipeline for foot trajectory estimation in the context of mobile gait analysis. PMID:28832511

  3. EMG normalization method based on grade 3 of manual muscle testing: Within- and between-day reliability of normalization tasks and application to gait analysis.

    PubMed

    Tabard-Fougère, Anne; Rose-Dulcina, Kevin; Pittet, Vincent; Dayer, Romain; Vuillerme, Nicolas; Armand, Stéphane

    2018-02-01

    Electromyography (EMG) is an important parameter in Clinical Gait Analysis (CGA), and is generally interpreted with timing of activation. EMG amplitude comparisons between individuals, muscles or days need normalization. There is no consensus on existing methods. The gold standard, maximum voluntary isometric contraction (MVIC), is not adapted to pathological populations because patients are often unable to perform an MVIC. The normalization method inspired by the isometric grade 3 of manual muscle testing (isoMMT3), which is the ability of a muscle to maintain a position against gravity, could be an interesting alternative. The aim of this study was to evaluate the within- and between-day reliability of the isoMMT3 EMG normalizing method during gait compared with the conventional MVIC method. Lower limb muscles EMG (gluteus medius, rectus femoris, tibialis anterior, semitendinosus) were recorded bilaterally in nine healthy participants (five males, aged 29.7±6.2years, BMI 22.7±3.3kgm -2 ) giving a total of 18 independent legs. Three repeated measurements of the isoMMT3 and MVIC exercises were performed with an EMG recording. EMG amplitude of the muscles during gait was normalized by these two methods. This protocol was repeated one week later. Within- and between-day reliability of normalization tasks were similar for isoMMT3 and MVIC methods. Within- and between-day reliability of gait EMG normalized by isoMMT3 was higher than with MVIC normalization. These results indicate that EMG normalization using isoMMT3 is a reliable method with no special equipment needed and will support CGA interpretation. The next step will be to evaluate this method in pathological populations. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Non-invasive detection of the freezing of gait in Parkinson's disease using spectral and wavelet features.

    PubMed

    Nazarzadeh, Kimia; Arjunan, Sridhar P; Kumar, Dinesh K; Das, Debi Prasad

    2016-08-01

    In this study, we have analyzed the accelerometer data recorded during gait analysis of Parkinson disease patients for detecting freezing of gait (FOG) episodes. The proposed method filters the recordings for noise reduction of the leg movement changes and computes the wavelet coefficients to detect FOG events. Publicly available FOG database was used and the technique was evaluated using receiver operating characteristic (ROC) analysis. Results show a higher performance of the wavelet feature in discrimination of the FOG events from the background activity when compared with the existing technique.

  5. Variations in Kinematics during Clinical Gait Analysis in Stroke Patients

    PubMed Central

    Boudarham, Julien; Roche, Nicolas; Pradon, Didier; Bonnyaud, Céline; Bensmail, Djamel; Zory, Raphael

    2013-01-01

    In addition to changes in spatio-temporal and kinematic parameters, patients with stroke exhibit fear of falling as well as fatigability during gait. These changes could compromise interpretation of data from gait analysis. The aim of this study was to determine if the gait of hemiplegic patients changes significantly over successive gait trials. Forty two stroke patients and twenty healthy subjects performed 9 gait trials during a gait analysis session. The mean and variability of spatio-temporal and kinematic joint parameters were analyzed during 3 groups of consecutive gait trials (1–3, 4–6 and 7–9). Principal component analysis was used to reduce the number of variables from the joint kinematic waveforms and to identify the parts of the gait cycle which changed during the gait analysis session. The results showed that i) spontaneous gait velocity and the other spatio-temporal parameters significantly increased, and ii) gait variability decreased, over the last 6 gait trials compared to the first 3, for hemiplegic patients but not healthy subjects. Principal component analysis revealed changes in the sagittal waveforms of the hip, knee and ankle for hemiplegic patients after the first 3 gait trials. These results suggest that at the beginning of the gait analysis session, stroke patients exhibited phase of adaptation,characterized by a “cautious gait” but no fatigue was observed. PMID:23799100

  6. Towards Real-Time Detection of Gait Events on Different Terrains Using Time-Frequency Analysis and Peak Heuristics Algorithm.

    PubMed

    Zhou, Hui; Ji, Ning; Samuel, Oluwarotimi Williams; Cao, Yafei; Zhao, Zheyi; Chen, Shixiong; Li, Guanglin

    2016-10-01

    Real-time detection of gait events can be applied as a reliable input to control drop foot correction devices and lower-limb prostheses. Among the different sensors used to acquire the signals associated with walking for gait event detection, the accelerometer is considered as a preferable sensor due to its convenience of use, small size, low cost, reliability, and low power consumption. Based on the acceleration signals, different algorithms have been proposed to detect toe off (TO) and heel strike (HS) gait events in previous studies. While these algorithms could achieve a relatively reasonable performance in gait event detection, they suffer from limitations such as poor real-time performance and are less reliable in the cases of up stair and down stair terrains. In this study, a new algorithm is proposed to detect the gait events on three walking terrains in real-time based on the analysis of acceleration jerk signals with a time-frequency method to obtain gait parameters, and then the determination of the peaks of jerk signals using peak heuristics. The performance of the newly proposed algorithm was evaluated with eight healthy subjects when they were walking on level ground, up stairs, and down stairs. Our experimental results showed that the mean F1 scores of the proposed algorithm were above 0.98 for HS event detection and 0.95 for TO event detection on the three terrains. This indicates that the current algorithm would be robust and accurate for gait event detection on different terrains. Findings from the current study suggest that the proposed method may be a preferable option in some applications such as drop foot correction devices and leg prostheses.

  7. Towards Real-Time Detection of Gait Events on Different Terrains Using Time-Frequency Analysis and Peak Heuristics Algorithm

    PubMed Central

    Zhou, Hui; Ji, Ning; Samuel, Oluwarotimi Williams; Cao, Yafei; Zhao, Zheyi; Chen, Shixiong; Li, Guanglin

    2016-01-01

    Real-time detection of gait events can be applied as a reliable input to control drop foot correction devices and lower-limb prostheses. Among the different sensors used to acquire the signals associated with walking for gait event detection, the accelerometer is considered as a preferable sensor due to its convenience of use, small size, low cost, reliability, and low power consumption. Based on the acceleration signals, different algorithms have been proposed to detect toe off (TO) and heel strike (HS) gait events in previous studies. While these algorithms could achieve a relatively reasonable performance in gait event detection, they suffer from limitations such as poor real-time performance and are less reliable in the cases of up stair and down stair terrains. In this study, a new algorithm is proposed to detect the gait events on three walking terrains in real-time based on the analysis of acceleration jerk signals with a time-frequency method to obtain gait parameters, and then the determination of the peaks of jerk signals using peak heuristics. The performance of the newly proposed algorithm was evaluated with eight healthy subjects when they were walking on level ground, up stairs, and down stairs. Our experimental results showed that the mean F1 scores of the proposed algorithm were above 0.98 for HS event detection and 0.95 for TO event detection on the three terrains. This indicates that the current algorithm would be robust and accurate for gait event detection on different terrains. Findings from the current study suggest that the proposed method may be a preferable option in some applications such as drop foot correction devices and leg prostheses. PMID:27706086

  8. Do physical examination and CT-scan measures of femoral neck anteversion and tibial torsion relate to each other?

    PubMed

    Sangeux, Morgan; Mahy, Jessica; Graham, H Kerr

    2014-01-01

    Informed clinical decision making for femoral and/or tibial de-rotation osteotomies requires accurate measurement of patient function through gait analysis and anatomy through physical examination of bony torsions. Validity of gait analysis has been extensively studied; however, controversy remains regarding the accuracy of physical examination measurements of femoral and tibial torsion. Comparison between CT-scans and physical examination measurements of femoral neck anteversion (FNA) and external tibial torsion (ETT) were retrospectively obtained for 98 (FNA) and 64 (ETT) patients who attended a tertiary hospital for instrumented gait analysis between 2007 and 2010. The physical examination methods studied for femoral neck anteversion were the trochanteric prominence angle test (TPAT) and the maximum hip rotation arc midpoint (Arc midpoint) and for external tibial torsion the transmalleolar axis (TMA). Results showed that all physical examination measurements statistically differed to the CT-scans (bias(standard deviation): -2(14) for TPAT, -10(12) for Arc midpoint and -16(9) for TMA). Bland and Altman plots showed that method disagreements increased with increasing bony torsions in all cases but notably for TPAT. Regression analysis showed that only TMA and CT-scan measurement of external tibial torsion demonstrated good (R(2)=57%) correlation. Correlations for both TPAT (R(2)=14%) and Arc midpoint (R(2)=39%) with CT-scan measurements of FNA were limited. We conclude that physical examination should be considered as screening techniques rather than definitive measurement methods for FNA and ETT. Further research is required to develop more accurate measurement methods to accompany instrumented gait analysis. Copyright © 2013. Published by Elsevier B.V.

  9. Effect of rhythmic auditory stimulation on gait kinematic parameters of patients with multiple sclerosis.

    PubMed

    Shahraki, M; Sohrabi, M; Taheri Torbati, H R; Nikkhah, K; NaeimiKia, M

    2017-01-01

    Purpose: This study aimed to examine the effect of rhythmic auditory stimulation on gait kinematic parameters of patients with multiple sclerosis. Subjects and Methods: In this study, 18 subjects, comprising 4 males and 14 females with Multiple Sclerosis with expanded disability status scale of 3 to 6 were chosen. Subjects were selected by available and targeted sampling and were randomly divided into two experimental (n = 9) and control (n = 9) groups. Exercises were gait with rhythmic auditory stimulation by a metronome device, in addition to gait without stimulation for the experimental and control groups, respectively. Training was carried out for 3 weeks, with 30 min duration for each session 3 times a week. Stride length, stride time, double support time, cadence and gait speed were measured by motion analysis device. Results: There was a significant difference between stride length, stride time, double support time, cadence and gait speed in the experimental group, before and after the training. Furthermore, there was a significant difference between the experimental and control groups in the enhancement of stride length, stride time, cadence and gait speed in favor of the experimental group. While this difference was not significant for double support time. Conclusion: The results of this study showed that rhythmic auditory stimulation is an effective rehabilitation method to improve gait kinematic parameters in patients with multiple sclerosis.

  10. Functional asymmetry of gait in children and youth with low-grade scoliosis.

    PubMed

    Nowotny-Czupryna, Olga; Nowotny, Janusz; Brzek, Anna; Czupryna, Krzysztof

    2006-04-28

    Background. Compensation for abnormal alignment of body parts in scoliosis may occur above or below the pelvis. This manifests as dislocation of body parts or changes in the angular composition of the lower limbs. Compensation for unbalanced body arrangement through changes in pelvic tilt and lower limb joints are typically reflected in the gait pattern of the person with scoliosis. The aim of our research was to determine whether and how improper body arrangement in the frontal plane is reflected in the gait pattern of children and youth with lower degree scolioses. Material and method. Children and youth with scolioses of varying grade were examined. In addition to photogrammetric body posture examination, three-dimensional gait analysis was performed during particular gait phases. For each examined child the results of this analysis were compared to the posture parameters. Results. Varying signs of gait asymmetry were observed in the whole group of children and youth with scoliosis. The symptoms were connected with both general gait attributes (unisommetry and unisochrony) and further gait markers. The most obvious changes were observed in pelvis rotation during the swing phase and excessive pelvis elevation during the mid-stance phase. These deviations did not correlate significantly with the results of the static examination. Conclusions. The gait asymmetries observed in children and youth with low-grade scoliosis are non-specific, and probably depend on the individual capabilities of each person to compensate for deficiencies.

  11. Differential effects of rhythmic auditory stimulation and neurodevelopmental treatment/Bobath on gait patterns in adults with cerebral palsy: a randomized controlled trial.

    PubMed

    Kim, Soo Ji; Kwak, Eunmi E; Park, Eun Sook; Cho, Sung-Rae

    2012-10-01

    To investigate the effects of rhythmic auditory stimulation (RAS) on gait patterns in comparison with changes after neurodevelopmental treatment (NDT/Bobath) in adults with cerebral palsy. A repeated-measures analysis between the pretreatment and posttreatment tests and a comparison study between groups. Human gait analysis laboratory. Twenty-eight cerebral palsy patients with bilateral spasticity participated in this study. The subjects were randomly allocated to either neurodevelopmental treatment (n = 13) or rhythmic auditory stimulation (n = 15). Gait training with rhythmic auditory stimulation or neurodevelopmental treatment was performed three sessions per week for three weeks. Temporal and kinematic data were analysed before and after the intervention. Rhythmic auditory stimulation was provided using a combination of a metronome beat set to the individual's cadence and rhythmic cueing from a live keyboard, while neurodevelopmental treatment was implemented following the traditional method. Temporal data, kinematic parameters and gait deviation index as a measure of overall gait pathology were assessed. Temporal gait measures revealed that rhythmic auditory stimulation significantly increased cadence, walking velocity, stride length, and step length (P < 0.05). Kinematic data demonstrated that anterior tilt of the pelvis and hip flexion during a gait cycle was significantly ameliorated after rhythmic auditory stimulation (P < 0.05). Gait deviation index also showed modest improvement in cerebral palsy patients treated with rhythmic auditory stimulation (P < 0.05). However, neurodevelopmental treatment showed that internal and external rotations of hip joints were significantly improved, whereas rhythmic auditory stimulation showed aggravated maximal internal rotation in the transverse plane (P < 0.05). Gait training with rhythmic auditory stimulation or neurodevelopmental treatment elicited differential effects on gait patterns in adults with cerebral palsy.

  12. Gait Partitioning Methods: A Systematic Review

    PubMed Central

    Taborri, Juri; Palermo, Eduardo; Rossi, Stefano; Cappa, Paolo

    2016-01-01

    In the last years, gait phase partitioning has come to be a challenging research topic due to its impact on several applications related to gait technologies. A variety of sensors can be used to feed algorithms for gait phase partitioning, mainly classifiable as wearable or non-wearable. Among wearable sensors, footswitches or foot pressure insoles are generally considered as the gold standard; however, to overcome some inherent limitations of the former, inertial measurement units have become popular in recent decades. Valuable results have been achieved also though electromyography, electroneurography, and ultrasonic sensors. Non-wearable sensors, such as opto-electronic systems along with force platforms, remain the most accurate system to perform gait analysis in an indoor environment. In the present paper we identify, select, and categorize the available methodologies for gait phase detection, analyzing advantages and disadvantages of each solution. Finally, we comparatively examine the obtainable gait phase granularities, the usable computational methodologies and the optimal sensor placements on the targeted body segments. PMID:26751449

  13. Gait Partitioning Methods: A Systematic Review.

    PubMed

    Taborri, Juri; Palermo, Eduardo; Rossi, Stefano; Cappa, Paolo

    2016-01-06

    In the last years, gait phase partitioning has come to be a challenging research topic due to its impact on several applications related to gait technologies. A variety of sensors can be used to feed algorithms for gait phase partitioning, mainly classifiable as wearable or non-wearable. Among wearable sensors, footswitches or foot pressure insoles are generally considered as the gold standard; however, to overcome some inherent limitations of the former, inertial measurement units have become popular in recent decades. Valuable results have been achieved also though electromyography, electroneurography, and ultrasonic sensors. Non-wearable sensors, such as opto-electronic systems along with force platforms, remain the most accurate system to perform gait analysis in an indoor environment. In the present paper we identify, select, and categorize the available methodologies for gait phase detection, analyzing advantages and disadvantages of each solution. Finally, we comparatively examine the obtainable gait phase granularities, the usable computational methodologies and the optimal sensor placements on the targeted body segments.

  14. Locomotor Recovery in Spinal Cord Injury: Insights Beyond Walking Speed and Distance.

    PubMed

    Awai, Lea; Curt, Armin

    2016-08-01

    Recovery of locomotor function after incomplete spinal cord injury (iSCI) is clinically assessed through walking speed and distance, while improvements in these measures might not be in line with a normalization of gait quality and are, on their own, insensitive at revealing potential mechanisms underlying recovery. The objective of this study was to relate changes of gait parameters to the recovery of walking speed while distinguishing between parameters that rather reflect speed improvements from factors contributing to overall recovery. Kinematic data of 16 iSCI subjects were repeatedly recorded during in-patient rehabilitation. The responsiveness of gait parameters to walking speed was assessed by linear regression. Principal component analysis (PCA) was applied on the multivariate data across time to identify factors that contribute to recovery after iSCI. Parameters of gait cycle and movement dynamics were both responsive and closely related to the recovery of walking speed, which increased by 96%. Multivariate analysis revealed specific gait parameters (intralimb shape normality and consistency) that, although less related to speed increments, loaded highly on principal component one (PC1) (58.6%) explaining the highest proportion of variance (i.e., recovery of outcome over time). Interestingly, measures of hip, knee, and ankle range of motion showed varying degrees of responsiveness (from very high to very low) while not contributing to gait recovery as revealed by PCA. The conjunct application of two analysis methods distinguishes gait parameters that simply reflect increased walking speed from parameters that actually contribute to gait recovery in iSCI. This distinction may be of value for the evaluation of interventions for locomotor recovery.

  15. Gait-Event-Based Synchronization Method for Gait Rehabilitation Robots via a Bioinspired Adaptive Oscillator.

    PubMed

    Chen, Gong; Qi, Peng; Guo, Zhao; Yu, Haoyong

    2017-06-01

    In the field of gait rehabilitation robotics, achieving human-robot synchronization is very important. In this paper, a novel human-robot synchronization method using gait event information is proposed. This method includes two steps. First, seven gait events in one gait cycle are detected in real time with a hidden Markov model; second, an adaptive oscillator is utilized to estimate the stride percentage of human gait using any one of the gait events. Synchronous reference trajectories for the robot are then generated with the estimated stride percentage. This method is based on a bioinspired adaptive oscillator, which is a mathematical tool, first proposed to explain the phenomenon of synchronous flashing among fireflies. The proposed synchronization method is implemented in a portable knee-ankle-foot robot and tested in 15 healthy subjects. This method has the advantages of simple structure, flexible selection of gait events, and fast adaptation. Gait event is the only information needed, and hence the performance of synchronization holds when an abnormal gait pattern is involved. The results of the experiments reveal that our approach is efficient in achieving human-robot synchronization and feasible for rehabilitation robotics application.

  16. Gait Phase Recognition for Lower-Limb Exoskeleton with Only Joint Angular Sensors

    PubMed Central

    Liu, Du-Xin; Wu, Xinyu; Du, Wenbin; Wang, Can; Xu, Tiantian

    2016-01-01

    Gait phase is widely used for gait trajectory generation, gait control and gait evaluation on lower-limb exoskeletons. So far, a variety of methods have been developed to identify the gait phase for lower-limb exoskeletons. Angular sensors on lower-limb exoskeletons are essential for joint closed-loop controlling; however, other types of sensors, such as plantar pressure, attitude or inertial measurement unit, are not indispensable.Therefore, to make full use of existing sensors, we propose a novel gait phase recognition method for lower-limb exoskeletons using only joint angular sensors. The method consists of two procedures. Firstly, the gait deviation distances during walking are calculated and classified by Fisher’s linear discriminant method, and one gait cycle is divided into eight gait phases. The validity of the classification results is also verified based on large gait samples. Secondly, we build a gait phase recognition model based on multilayer perceptron and train it with the phase-labeled gait data. The experimental result of cross-validation shows that the model has a 94.45% average correct rate of set (CRS) and an 87.22% average correct rate of phase (CRP) on the testing set, and it can predict the gait phase accurately. The novel method avoids installing additional sensors on the exoskeleton or human body and simplifies the sensory system of the lower-limb exoskeleton. PMID:27690023

  17. Changes in frontal plane dynamics and the loading response phase of the gait cycle are characteristic of severe knee osteoarthritis application of a multidimensional analysis technique.

    PubMed

    Astephen, J L; Deluzio, K J

    2005-02-01

    Osteoarthritis of the knee is related to many correlated mechanical factors that can be measured with gait analysis. Gait analysis results in large data sets. The analysis of these data is difficult due to the correlated, multidimensional nature of the measures. A multidimensional model that uses two multivariate statistical techniques, principal component analysis and discriminant analysis, was used to discriminate between the gait patterns of the normal subject group and the osteoarthritis subject group. Nine time varying gait measures and eight discrete measures were included in the analysis. All interrelationships between and within the measures were retained in the analysis. The multidimensional analysis technique successfully separated the gait patterns of normal and knee osteoarthritis subjects with a misclassification error rate of <6%. The most discriminatory feature described a static and dynamic alignment factor. The second most discriminatory feature described a gait pattern change during the loading response phase of the gait cycle. The interrelationships between gait measures and between the time instants of the gait cycle can provide insight into the mechanical mechanisms of pathologies such as knee osteoarthritis. These results suggest that changes in frontal plane loading and alignment and the loading response phase of the gait cycle are characteristic of severe knee osteoarthritis gait patterns. Subsequent investigations earlier in the disease process may suggest the importance of these factors to the progression of knee osteoarthritis.

  18. Femoral anteversion and tibial torsion only explain 25% of variance in regression analysis of foot progression angle in children with diplegic cerebral palsy

    PubMed Central

    2013-01-01

    Background The relationship between torsional bony deformities and rotational gait parameters has not been sufficiently investigated. This study was to investigate the degree of contribution of torsional bony deformities to rotational gait parameters in patients with diplegic cerebral palsy (CP). Methods Thirty three legs from 33 consecutive ambulatory patients (average age 9.5 years, SD 6.9 years; 20 males and 13 females) with diplegic CP who underwent preoperative three dimensional gait analysis, foot radiographs, and computed tomography (CT) were included. Adjusted foot progression angle (FPA) was retrieved from gait analysis by correcting pelvic rotation from conventional FPA, which represented the rotational gait deviation of the lower extremity from the tip of the femoral head to the foot. Correlations between rotational gait parameters (FPA, adjusted FPA, average pelvic rotation, average hip rotation, and average knee rotation) and radiologic measurements (acetabular version, femoral anteversion, knee torsion, tibial torsion, and anteroposteriortalo-first metatarsal angle) were analyzed. Multiple regression analysis was performed to identify significant contributing radiographic measurements to adjusted FPA. Results Adjusted FPA was significantly correlated with FPA (r=0.837, p<0.001), contralateral FPA (r=0.492, p=0.004), pelvic rotation during gait (r=−0.489, p=0.004), knee rotation during gait (r=0.376, p=0.031), and femoral anteversion (r=0.350, p=0.046). In multiple regression analysis, femoral anteversion (p=0.026) and tibial torsion (p=0.034) were found to be the significant contributing structural deformities to the adjusted FPA (R2=0.247). Conclusions Femoral anteversion and tibial torsion were found to be the significant structural deformities that could affect adjusted FPA in patients with diplegic CP. Femoral anteversion and tibial torsion could explain only 24.7% of adjusted FPA. PMID:23767833

  19. An Ambulatory Method of Identifying Anterior Cruciate Ligament Reconstructed Gait Patterns

    PubMed Central

    Patterson, Matthew R.; Delahunt, Eamonn; Sweeney, Kevin T.; Caulfield, Brian

    2014-01-01

    The use of inertial sensors to characterize pathological gait has traditionally been based on the calculation of temporal and spatial gait variables from inertial sensor data. This approach has proved successful in the identification of gait deviations in populations where substantial differences from normal gait patterns exist; such as in Parkinsonian gait. However, it is not currently clear if this approach could identify more subtle gait deviations, such as those associated with musculoskeletal injury. This study investigates whether additional analysis of inertial sensor data, based on quantification of gyroscope features of interest, would provide further discriminant capability in this regard. The tested cohort consisted of a group of anterior cruciate ligament reconstructed (ACL-R) females and a group of non-injured female controls, each performed ten walking trials. Gait performance was measured simultaneously using inertial sensors and an optoelectronic marker based system. The ACL-R group displayed kinematic and kinetic deviations from the control group, but no temporal or spatial deviations. This study demonstrates that quantification of gyroscope features can successfully identify changes associated with ACL-R gait, which was not possible using spatial or temporal variables. This finding may also have a role in other clinical applications where small gait deviations exist. PMID:24451464

  20. Gait Event Detection in Real-World Environment for Long-Term Applications: Incorporating Domain Knowledge Into Time-Frequency Analysis.

    PubMed

    Khandelwal, Siddhartha; Wickstrom, Nicholas

    2016-12-01

    Detecting gait events is the key to many gait analysis applications that would benefit from continuous monitoring or long-term analysis. Most gait event detection algorithms using wearable sensors that offer a potential for use in daily living have been developed from data collected in controlled indoor experiments. However, for real-word applications, it is essential that the analysis is carried out in humans' natural environment; that involves different gait speeds, changing walking terrains, varying surface inclinations and regular turns among other factors. Existing domain knowledge in the form of principles or underlying fundamental gait relationships can be utilized to drive and support the data analysis in order to develop robust algorithms that can tackle real-world challenges in gait analysis. This paper presents a novel approach that exhibits how domain knowledge about human gait can be incorporated into time-frequency analysis to detect gait events from long-term accelerometer signals. The accuracy and robustness of the proposed algorithm are validated by experiments done in indoor and outdoor environments with approximately 93 600 gait events in total. The proposed algorithm exhibits consistently high performance scores across all datasets in both, indoor and outdoor environments.

  1. Three Dimensional Gait Analysis Using Wearable Acceleration and Gyro Sensors Based on Quaternion Calculations

    PubMed Central

    Tadano, Shigeru; Takeda, Ryo; Miyagawa, Hiroaki

    2013-01-01

    This paper proposes a method for three dimensional gait analysis using wearable sensors and quaternion calculations. Seven sensor units consisting of a tri-axial acceleration and gyro sensors, were fixed to the lower limbs. The acceleration and angular velocity data of each sensor unit were measured during level walking. The initial orientations of the sensor units were estimated using acceleration data during upright standing position and the angular displacements were estimated afterwards using angular velocity data during gait. Here, an algorithm based on quaternion calculation was implemented for orientation estimation of the sensor units. The orientations of the sensor units were converted to the orientations of the body segments by a rotation matrix obtained from a calibration trial. Body segment orientations were then used for constructing a three dimensional wire frame animation of the volunteers during the gait. Gait analysis was conducted on five volunteers, and results were compared with those from a camera-based motion analysis system. Comparisons were made for the joint trajectory in the horizontal and sagittal plane. The average RMSE and correlation coefficient (CC) were 10.14 deg and 0.98, 7.88 deg and 0.97, 9.75 deg and 0.78 for the hip, knee and ankle flexion angles, respectively. PMID:23877128

  2. Analysis of Modification Mechanism of Gait with Rhythmic Cueing Training Paradigm

    NASA Astrophysics Data System (ADS)

    Muto, Takeshi; Kanai, Tetsuya; Sakuta, Hiroshi; Miyake, Yoshihiro

    In this research, we applied the gait training method which takes in the rhythmic auditory stimulation as a pace maker to the assistance of gait motion, and analyzed the dynamical stability of the period and trajectory of the lower limbs' motions. As the result, it was clarified that, in the training style which presents a constant rhythm, trajectory of ankles was modified as the stable state which has the historical property, but the period of footsteps was not modified but susceptible to the external environment. This result suggests that the hierarchical modification mechanism of motor schema of gait is realized by the connection between the immediate and historical modification system.

  3. Validation of a commercial inertial sensor system for spatiotemporal gait measurements in children.

    PubMed

    Lanovaz, Joel L; Oates, Alison R; Treen, Tanner T; Unger, Janelle; Musselman, Kristin E

    2017-01-01

    Although inertial sensor systems are becoming a popular tool for gait analysis in both healthy and pathological adult populations, there are currently no data on the validity of these systems for use with children. The purpose of this study was to validate spatiotemporal data from a commercial inertial sensor system (MobilityLab) in typically-developing children. Data from 10 children (5 males; 3.0-8.3 years, mean=5.1) were collected simultaneously from MobilityLab and 3D motion capture during gait at self-selected and fast walking speeds. Spatiotemporal parameters were compared between the two methods using a Bland-Altman method. The results indicate that, while the temporal gait measurements were similar between the two systems, MobilityLab demonstrated a consistent bias with respect to measurement of the spatial data (stride length). This error is likely due to differences in relative leg length and gait characteristics in children compared to the MobilityLab adult reference population used to develop the stride length algorithm. A regression-based equation was developed based on the current data to correct the MobilityLab stride length output. The correction was based on leg length, stride time, and shank range-of-motion, each of which were independently associated with stride length. Once the correction was applied, all of the spatiotemporal parameters evaluated showed good agreement. The results of this study indicate that MobilityLab is a valid tool for gait analysis in typically-developing children. Further research is needed to determine the efficacy of this system for use in children suffering from pathologies that impact gait mechanics. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Computational intelligence in gait research: a perspective on current applications and future challenges.

    PubMed

    Lai, Daniel T H; Begg, Rezaul K; Palaniswami, Marimuthu

    2009-09-01

    Our mobility is an important daily requirement so much so that any disruption to it severely degrades our perceived quality of life. Studies in gait and human movement sciences, therefore, play a significant role in maintaining the well-being of our mobility. Current gait analysis involves numerous interdependent gait parameters that are difficult to adequately interpret due to the large volume of recorded data and lengthy assessment times in gait laboratories. A proposed solution to these problems is computational intelligence (CI), which is an emerging paradigm in biomedical engineering most notably in pathology detection and prosthesis design. The integration of CI technology in gait systems facilitates studies in disorders caused by lower limb defects, cerebral disorders, and aging effects by learning data relationships through a combination of signal processing and machine learning techniques. Learning paradigms, such as supervised learning, unsupervised learning, and fuzzy and evolutionary algorithms, provide advanced modeling capabilities for biomechanical systems that in the past have relied heavily on statistical analysis. CI offers the ability to investigate nonlinear data relationships, enhance data interpretation, design more efficient diagnostic methods, and extrapolate model functionality. These are envisioned to result in more cost-effective, efficient, and easy-to-use systems, which would address global shortages in medical personnel and rising medical costs. This paper surveys current signal processing and CI methodologies followed by gait applications ranging from normal gait studies and disorder detection to artificial gait simulation. We review recent systems focusing on the existing challenges and issues involved in making them successful. We also examine new research in sensor technologies for gait that could be combined with these intelligent systems to develop more effective healthcare solutions.

  5. The effect of intracortical bone pin application on kinetics and tibiocalcaneal kinematics of walking gait.

    PubMed

    Maiwald, Christian; Arndt, Anton; Nester, Chris; Jones, Richard; Lundberg, Arne; Wolf, Peter

    2017-02-01

    Bone anchored markers using intracortical bone pins are one of the few available methods for analyzing skeletal motion during human gait in-vivo without errors induced by soft tissue artifacts. However, bone anchored markers require local anesthesia and may alter the motor control and motor output during gait. The purpose of this study was to examine the effect of local anesthesia and the use of bone anchored markers on typical gait analysis variables. Five subjects were analyzed in two different gait analysis sessions. In the first session, a protocol with skin markers was used. In the second session, bone anchored markers were added after local anesthesia was applied. For both sessions, three dimensional infrared kinematics of the calcaneus and tibia segments, ground reaction forces, and plantar pressure data were collected. 95% confidence intervals and boxplots were used to compare protocols and assess the data distribution and data variability for each subject. Although considerable variation was found between subjects, within-subject comparison of the two protocols revealed non-systematic effects on the target variables. Two of the five subjects walked at reduced gait speed during the bone pin session, which explained the between-session differences found in kinetic and kinematic variables. The remaining three subjects did not systematically alter their gait pattern between the two sessions. Results support the hypothesis that local anesthesia and the presence of bone pins still allow a valid gait pattern to be analyzed. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Gait Analysis in Adults with Intellectual Disabilities Living in a Residential Facility

    ERIC Educational Resources Information Center

    Salb, Johannes; Lindemann, Ulrich; Woodward, Carol; Almutaseb, Sanaa; Becker, Clemens; Sieber, Cornel; Freiberger, Ellen

    2017-01-01

    Background: Mobility limitations are of particular interest in people with intellectual disabilities. The aim of this study was to present feasibility and mean values of gait parameters in people with intellectual disability and it was hypothesized that several trials would be necessary to gain stable values for this cohort. Material and Methods:…

  7. A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait

    PubMed Central

    2014-01-01

    Background Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting number of steps to be analyzed. Traditional measuring gait systems carry out their measurement at frequencies oscillating between 60 to 100 Hz. It can be argued about the need of higher sampling rates for gait measurements. However small displacements of the knee or hip for example, cannot be seen with low frequencies required a more detailed sampling and higher frequency sampling. Bearing this in mind, in this paper is presented a 250 Hz system based on accelerometers for gait measurement, and the particularities of knee and hip angles during gait are highlighted. Methods The system was designed with a PCI data acquisition card instrumented with an FPGA to achieve a rate sample of 250 Hz. The accelerometers were placed in thighs and legs to calculate the joint angles of hip and knee in the sagittal plane. The angles were estimated using the acceleration polygon method without integrating the acceleration and without filters. Results The gait of thirty healthy people of Mexican phenotype was analyzed over a flat floor free of obstacles. The results showed the gait phases and particularities associated with the walking style and people's laterality; the movement patterns were similar in the thirty persons. Based on the results, the particularities as the maximum amplitude in the angles and the shape in the movement patterns were related to the anthropometry and people phenotype. Conclusions The sampling frequency was essential to record 340 samples in single gait cycle and so registering the gait cycle with its particularities. In this work were recorded an average of 8 to 10 gait cycles, and the results showed variation regarding works carried out in biomechanics laboratories; this variation was related to the method and reference frame used to obtain the joint angles and the accuracy of measurement system. PMID:24684720

  8. Underwater gait analysis in Parkinson's disease.

    PubMed

    Volpe, Daniele; Pavan, Davide; Morris, Meg; Guiotto, Annamaria; Iansek, Robert; Fortuna, Sofia; Frazzitta, Giuseppe; Sawacha, Zimi

    2017-02-01

    Although hydrotherapy is one of the physical therapies adopted to optimize gait rehabilitation in people with Parkinson disease, the quantitative measurement of gait-related outcomes has not been provided yet. This work aims to document the gait improvements in a group of parkinsonians after a hydrotherapy program through 2D and 3D underwater and on land gait analysis. Thirty-four parkinsonians and twenty-two controls were enrolled, divided into two different cohorts. In the first one, 2 groups of patients underwent underwater or land based walking training; controls underwent underwater walking training. Hence pre-treatment 2D underwater and on land gait analysis were performed, together with post-treatment on land gait analysis. Considering that current literature documented a reduced movement amplitude in parkinsonians across all lower limb joints in all movement planes, 3D underwater and on land gait analysis were performed on a second cohort of subjects (10 parkinsonians and 10 controls) who underwent underwater gait training. Baseline land 2D and 3D gait analysis in parkinsonians showed shorter stride length and slower speed than controls, in agreement with previous findings. Comparison between underwater and on land gait analysis showed reduction in stride length, cadence and speed on both parkinsonians and controls. Although patients who underwent underwater treatment exhibited significant changes on spatiotemporal parameters and sagittal plane lower limb kinematics, 3D gait analysis documented a significant (p<0.05) improvement in all movement planes. These data deserve attention for research directions promoting the optimal recovery and maintenance of walking ability. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  9. Assessing the efficacy of perioperative oral carprofen after cranial cruciate surgery using noninvasive, objective pressure platform gait analysis.

    PubMed

    Horstman, Christopher L; Conzemius, Michael G; Evans, Richard; Gordon, Wanda J

    2004-01-01

    To document, using pressure platform gait analysis, the effect of perioperative oral carprofen on limb function and pain after cranial cruciate ligament surgery in dogs. Blinded, prospective clinical investigation. Twenty dogs with naturally occurring unilateral cranial cruciate disease. Physiologic indices, subjective pain scoring, and pressure platform gait analyses were performed before and 24, 48, and 72 hours after surgery. Correlations were assessed between methods of evaluation and the data was compared across treatment groups. No strong correlations were noted between physiologic data, subjective scoring systems, or gait analysis data at a walk or stance. Although average measures of limb function were nearly twice as large in dogs treated with carprofen, no significant differences between groups over time were identified. No significant differences were noted in any other measure of pain or limb function. Power analysis of peak vertical force at a walk indicated that significant difference would have been detected had the number of dogs in each group been increased to 35. When limb function was assessed with pressure platform gait analysis no statistical difference was noted between groups with respect to PVF and VI at a walk or stance, although average ground reaction forces for dogs in the carprofen group were greater than the traditional pain management group at all time points. Oral carprofen appears to provide some benefit for the treatment of postoperative orthopedic pain.

  10. Gait biomechanics in the era of data science.

    PubMed

    Ferber, Reed; Osis, Sean T; Hicks, Jennifer L; Delp, Scott L

    2016-12-08

    Data science has transformed fields such as computer vision and economics. The ability of modern data science methods to extract insights from large, complex, heterogeneous, and noisy datasets is beginning to provide a powerful complement to the traditional approaches of experimental motion capture and biomechanical modeling. The purpose of this article is to provide a perspective on how data science methods can be incorporated into our field to advance our understanding of gait biomechanics and improve treatment planning procedures. We provide examples of how data science approaches have been applied to biomechanical data. We then discuss the challenges that remain for effectively using data science approaches in clinical gait analysis and gait biomechanics research, including the need for new tools, better infrastructure and incentives for sharing data, and education across the disciplines of biomechanics and data science. By addressing these challenges, we can revolutionize treatment planning and biomechanics research by capitalizing on the wealth of knowledge gained by gait researchers over the past decades and the vast, but often siloed, data that are collected in clinical and research laboratories around the world. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Single-Camera-Based Method for Step Length Symmetry Measurement in Unconstrained Elderly Home Monitoring.

    PubMed

    Cai, Xi; Han, Guang; Song, Xin; Wang, Jinkuan

    2017-11-01

    single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring. To build unconstrained monitoring environments, we propose a method to measure step length symmetry ratio (a useful gait parameter representing gait symmetry without significant relationship with age) from unconstrained straight walking using a single camera, without strict restrictions on walking directions or routes. according to projective geometry theory, we first develop a calculation formula of step length ratio for the case of unconstrained straight-line walking. Then, to adapt to general cases, we propose to modify noncollinear footprints, and accordingly provide general procedure for step length ratio extraction from unconstrained straight walking. Our method achieves a mean absolute percentage error (MAPE) of 1.9547% for 15 subjects' normal and abnormal side-view gaits, and also obtains satisfactory MAPEs for non-side-view gaits (2.4026% for 45°-view gaits and 3.9721% for 30°-view gaits). The performance is much better than a well-established monocular gait measurement system suitable only for side-view gaits with a MAPE of 3.5538%. Independently of walking directions, our method can accurately estimate step length ratios from unconstrained straight walking. This demonstrates our method is applicable for elders' daily gait monitoring to provide valuable information for elderly health care, such as abnormal gait recognition, fall risk assessment, etc. single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring. To build unconstrained monitoring environments, we propose a method to measure step length symmetry ratio (a useful gait parameter representing gait symmetry without significant relationship with age) from unconstrained straight walking using a single camera, without strict restrictions on walking directions or routes. according to projective geometry theory, we first develop a calculation formula of step length ratio for the case of unconstrained straight-line walking. Then, to adapt to general cases, we propose to modify noncollinear footprints, and accordingly provide general procedure for step length ratio extraction from unconstrained straight walking. Our method achieves a mean absolute percentage error (MAPE) of 1.9547% for 15 subjects' normal and abnormal side-view gaits, and also obtains satisfactory MAPEs for non-side-view gaits (2.4026% for 45°-view gaits and 3.9721% for 30°-view gaits). The performance is much better than a well-established monocular gait measurement system suitable only for side-view gaits with a MAPE of 3.5538%. Independently of walking directions, our method can accurately estimate step length ratios from unconstrained straight walking. This demonstrates our method is applicable for elders' daily gait monitoring to provide valuable information for elderly health care, such as abnormal gait recognition, fall risk assessment, etc.

  12. Extraction of human gait signatures: an inverse kinematic approach using Groebner basis theory applied to gait cycle analysis

    NASA Astrophysics Data System (ADS)

    Barki, Anum; Kendricks, Kimberly; Tuttle, Ronald F.; Bunker, David J.; Borel, Christoph C.

    2013-05-01

    This research highlights the results obtained from applying the method of inverse kinematics, using Groebner basis theory, to the human gait cycle to extract and identify lower extremity gait signatures. The increased threat from suicide bombers and the force protection issues of today have motivated a team at Air Force Institute of Technology (AFIT) to research pattern recognition in the human gait cycle. The purpose of this research is to identify gait signatures of human subjects and distinguish between subjects carrying a load to those subjects without a load. These signatures were investigated via a model of the lower extremities based on motion capture observations, in particular, foot placement and the joint angles for subjects affected by carrying extra load on the body. The human gait cycle was captured and analyzed using a developed toolkit consisting of an inverse kinematic motion model of the lower extremity and a graphical user interface. Hip, knee, and ankle angles were analyzed to identify gait angle variance and range of motion. Female subjects exhibited the most knee angle variance and produced a proportional correlation between knee flexion and load carriage.

  13. Analysis of several methods and inertial sensors locations to assess gait parameters in able-bodied subjects.

    PubMed

    Ben Mansour, Khaireddine; Rezzoug, Nasser; Gorce, Philippe

    2015-10-01

    The purpose of this paper was to determine which types of inertial sensors and which advocated locations should be used for reliable and accurate gait event detection and temporal parameter assessment in normal adults. In addition, we aimed to remove the ambiguity found in the literature of the definition of the initial contact (IC) from the lumbar accelerometer. Acceleration and angular velocity data was gathered from the lumbar region and the distal edge of each shank. This data was evaluated in comparison to an instrumented treadmill and an optoelectronic system during five treadmill speed sessions. The lumbar accelerometer showed that the peak of the anteroposterior component was the most accurate for IC detection. Similarly, the valley that followed the peak of the vertical component was the most precise for terminal contact (TC) detection. Results based on ANOVA and Tukey tests showed that the set of inertial methods was suitable for temporal gait assessment and gait event detection in able-bodied subjects. For gait event detection, an exception was found with the shank accelerometer. The tool was suitable for temporal parameters assessment, despite the high root mean square error on the detection of IC (RMSEIC) and TC (RMSETC). The shank gyroscope was found to be as accurate as the kinematic method since the statistical tests revealed no significant difference between the two techniques for the RMSE off all gait events and temporal parameters. The lumbar and shank accelerometers were the most accurate alternative to the shank gyroscope for gait event detection and temporal parameters assessment, respectively. Copyright © 2015. Published by Elsevier B.V.

  14. View-invariant gait recognition method by three-dimensional convolutional neural network

    NASA Astrophysics Data System (ADS)

    Xing, Weiwei; Li, Ying; Zhang, Shunli

    2018-01-01

    Gait as an important biometric feature can identify a human at a long distance. View change is one of the most challenging factors for gait recognition. To address the cross view issues in gait recognition, we propose a view-invariant gait recognition method by three-dimensional (3-D) convolutional neural network. First, 3-D convolutional neural network (3DCNN) is introduced to learn view-invariant feature, which can capture the spatial information and temporal information simultaneously on normalized silhouette sequences. Second, a network training method based on cross-domain transfer learning is proposed to solve the problem of the limited gait training samples. We choose the C3D as the basic model, which is pretrained on the Sports-1M and then fine-tune C3D model to adapt gait recognition. In the recognition stage, we use the fine-tuned model to extract gait features and use Euclidean distance to measure the similarity of gait sequences. Sufficient experiments are carried out on the CASIA-B dataset and the experimental results demonstrate that our method outperforms many other methods.

  15. The value of the NDT-Bobath method in post-stroke gait training.

    PubMed

    Mikołajewska, Emilia

    2013-01-01

    Stroke is perceived a major cause of disability, including gait disorders. Looking for more effective methods of gait reeducation in post-stroke survivors is one of the most important issues in contemporary neurorehabilitation. Following a stroke, patients suffer from gait disorders. The aim of this paper is to present the outcomes of a study of post-stroke gait reeducation using the NeuroDevelopmental Treatment-Bobath (NDT-Bobath) method. The research was conducted among 60 adult patients who had undergone ischemic stroke. These patients were treated using the NDT-Bobath method. These patients' gait reeducation was assessed using spatio-temporal gait parameters (gait velocity, cadence and stride length). Measurements of these parameters were conducted by the same therapist twice: on admission, and after the tenth session of gait reeducation. Among the 60 patients involved in the study, the results were as follows: in terms of gait velocity, recovery was observed in 39 cases (65%), in terms of cadence, recovery was observed in 39 cases (65%), in terms of stride length, recovery was observed in 50 cases (83.33%). Benefits were observed after short-term therapy, reflected by measurable statistically significant changes in the patients' gait parameters.

  16. Measuring Gait Quality in Parkinson’s Disease through Real-Time Gait Phase Recognition

    PubMed Central

    Mileti, Ilaria; Germanotta, Marco; Di Sipio, Enrica; Imbimbo, Isabella; Pacilli, Alessandra; Erra, Carmen; Petracca, Martina; Del Prete, Zaccaria; Bentivoglio, Anna Rita; Padua, Luca

    2018-01-01

    Monitoring gait quality in daily activities through wearable sensors has the potential to improve medical assessment in Parkinson’s Disease (PD). In this study, four gait partitioning methods, two based on thresholds and two based on a machine learning approach, considering the four-phase model, were compared. The methods were tested on 26 PD patients, both in OFF and ON levodopa conditions, and 11 healthy subjects, during walking tasks. All subjects were equipped with inertial sensors placed on feet. Force resistive sensors were used to assess reference time sequence of gait phases. Goodness Index (G) was evaluated to assess accuracy in gait phases estimation. A novel synthetic index called Gait Phase Quality Index (GPQI) was proposed for gait quality assessment. Results revealed optimum performance (G < 0.25) for three tested methods and good performance (0.25 < G < 0.70) for one threshold method. The GPQI resulted significantly higher in PD patients than in healthy subjects, showing a moderate correlation with clinical scales score. Furthermore, in patients with severe gait impairment, GPQI was found higher in OFF than in ON state. Our results unveil the possibility of monitoring gait quality in PD through real-time gait partitioning based on wearable sensors. PMID:29558410

  17. The Novel Quantitative Technique for Assessment of Gait Symmetry Using Advanced Statistical Learning Algorithm

    PubMed Central

    Wu, Jianning; Wu, Bin

    2015-01-01

    The accurate identification of gait asymmetry is very beneficial to the assessment of at-risk gait in the clinical applications. This paper investigated the application of classification method based on statistical learning algorithm to quantify gait symmetry based on the assumption that the degree of intrinsic change in dynamical system of gait is associated with the different statistical distributions between gait variables from left-right side of lower limbs; that is, the discrimination of small difference of similarity between lower limbs is considered the reorganization of their different probability distribution. The kinetic gait data of 60 participants were recorded using a strain gauge force platform during normal walking. The classification method is designed based on advanced statistical learning algorithm such as support vector machine algorithm for binary classification and is adopted to quantitatively evaluate gait symmetry. The experiment results showed that the proposed method could capture more intrinsic dynamic information hidden in gait variables and recognize the right-left gait patterns with superior generalization performance. Moreover, our proposed techniques could identify the small significant difference between lower limbs when compared to the traditional symmetry index method for gait. The proposed algorithm would become an effective tool for early identification of the elderly gait asymmetry in the clinical diagnosis. PMID:25705672

  18. The novel quantitative technique for assessment of gait symmetry using advanced statistical learning algorithm.

    PubMed

    Wu, Jianning; Wu, Bin

    2015-01-01

    The accurate identification of gait asymmetry is very beneficial to the assessment of at-risk gait in the clinical applications. This paper investigated the application of classification method based on statistical learning algorithm to quantify gait symmetry based on the assumption that the degree of intrinsic change in dynamical system of gait is associated with the different statistical distributions between gait variables from left-right side of lower limbs; that is, the discrimination of small difference of similarity between lower limbs is considered the reorganization of their different probability distribution. The kinetic gait data of 60 participants were recorded using a strain gauge force platform during normal walking. The classification method is designed based on advanced statistical learning algorithm such as support vector machine algorithm for binary classification and is adopted to quantitatively evaluate gait symmetry. The experiment results showed that the proposed method could capture more intrinsic dynamic information hidden in gait variables and recognize the right-left gait patterns with superior generalization performance. Moreover, our proposed techniques could identify the small significant difference between lower limbs when compared to the traditional symmetry index method for gait. The proposed algorithm would become an effective tool for early identification of the elderly gait asymmetry in the clinical diagnosis.

  19. Gait phenotypes in paediatric hereditary spastic paraplegia revealed by dynamic time warping analysis and random forests

    PubMed Central

    Martín-Gonzalo, Juan Andrés; Rodríguez-Andonaegui, Irene; López-López, Javier; Pascual-Pascual, Samuel Ignacio

    2018-01-01

    The Hereditary Spastic Paraplegias (HSP) are a group of heterogeneous disorders with a wide spectrum of underlying neural pathology, and hence HSP patients express a variety of gait abnormalities. Classification of these phenotypes may help in monitoring disease progression and personalizing therapies. This is currently managed by measuring values of some kinematic and spatio-temporal parameters at certain moments during the gait cycle, either in the doctor´s surgery room or after very precise measurements produced by instrumental gait analysis (IGA). These methods, however, do not provide information about the whole structure of the gait cycle. Classification of the similarities among time series of IGA measured values of sagittal joint positions throughout the whole gait cycle can be achieved by hierarchical clustering analysis based on multivariate dynamic time warping (DTW). Random forests can estimate which are the most important isolated parameters to predict the classification revealed by DTW, since clinicians need to refer to them in their daily practice. We acquired time series of pelvic, hip, knee, ankle and forefoot sagittal angular positions from 26 HSP and 33 healthy children with an optokinetic IGA system. DTW revealed six gait patterns with different degrees of impairment of walking speed, cadence and gait cycle distribution and related with patient’s age, sex, GMFCS stage, concurrence of polyneuropathy and abnormal visual evoked potentials or corpus callosum. The most important parameters to differentiate patterns were mean pelvic tilt and hip flexion at initial contact. Longer time of support, decreased values of hip extension and increased knee flexion at initial contact can differentiate the mildest, near to normal HSP gait phenotype and the normal healthy one. Increased values of knee flexion at initial contact and delayed peak of knee flexion are important factors to distinguish GMFCS stages I from II-III and concurrence of polyneuropathy. PMID:29518090

  20. Towards more effective robotic gait training for stroke rehabilitation: a review

    PubMed Central

    2012-01-01

    Background Stroke is the most common cause of disability in the developed world and can severely degrade walking function. Robot-driven gait therapy can provide assistance to patients during training and offers a number of advantages over other forms of therapy. These potential benefits do not, however, seem to have been fully realised as of yet in clinical practice. Objectives This review determines ways in which robot-driven gait technology could be improved in order to achieve better outcomes in gait rehabilitation. Methods The literature on gait impairments caused by stroke is reviewed, followed by research detailing the different pathways to recovery. The outcomes of clinical trials investigating robot-driven gait therapy are then examined. Finally, an analysis of the literature focused on the technical features of the robot-based devices is presented. This review thus combines both clinical and technical aspects in order to determine the routes by which robot-driven gait therapy could be further developed. Conclusions Active subject participation in robot-driven gait therapy is vital to many of the potential recovery pathways and is therefore an important feature of gait training. Higher levels of subject participation and challenge could be promoted through designs with a high emphasis on robotic transparency and sufficient degrees of freedom to allow other aspects of gait such as balance to be incorporated. PMID:22953989

  1. Do you see what I see? Mobile eye-tracker contextual analysis and inter-rater reliability.

    PubMed

    Stuart, S; Hunt, D; Nell, J; Godfrey, A; Hausdorff, J M; Rochester, L; Alcock, L

    2018-02-01

    Mobile eye-trackers are currently used during real-world tasks (e.g. gait) to monitor visual and cognitive processes, particularly in ageing and Parkinson's disease (PD). However, contextual analysis involving fixation locations during such tasks is rarely performed due to its complexity. This study adapted a validated algorithm and developed a classification method to semi-automate contextual analysis of mobile eye-tracking data. We further assessed inter-rater reliability of the proposed classification method. A mobile eye-tracker recorded eye-movements during walking in five healthy older adult controls (HC) and five people with PD. Fixations were identified using a previously validated algorithm, which was adapted to provide still images of fixation locations (n = 116). The fixation location was manually identified by two raters (DH, JN), who classified the locations. Cohen's kappa correlation coefficients determined the inter-rater reliability. The algorithm successfully provided still images for each fixation, allowing manual contextual analysis to be performed. The inter-rater reliability for classifying the fixation location was high for both PD (kappa = 0.80, 95% agreement) and HC groups (kappa = 0.80, 91% agreement), which indicated a reliable classification method. This study developed a reliable semi-automated contextual analysis method for gait studies in HC and PD. Future studies could adapt this methodology for various gait-related eye-tracking studies.

  2. Wearable sensors objectively measure gait parameters in Parkinson’s disease

    PubMed Central

    Marxreiter, Franz; Gossler, Julia; Kohl, Zacharias; Reinfelder, Samuel; Gassner, Heiko; Aminian, Kamiar; Eskofier, Bjoern M.; Winkler, Jürgen; Klucken, Jochen

    2017-01-01

    Distinct gait characteristics like short steps and shuffling gait are prototypical signs commonly observed in Parkinson’s disease. Routinely assessed by observation through clinicians, gait is rated as part of categorical clinical scores. There is an increasing need to provide quantitative measurements of gait, e.g. to provide detailed information about disease progression. Recently, we developed a wearable sensor-based gait analysis system as diagnostic tool that objectively assesses gait parameter in Parkinson’s disease without the need of having a specialized gait laboratory. This system consists of inertial sensor units attached laterally to both shoes. The computed target of measures are spatiotemporal gait parameters including stride length and time, stance phase time, heel-strike and toe-off angle, toe clearance, and inter-stride variation from gait sequences. To translate this prototype into medical care, we conducted a cross-sectional study including 190 Parkinson’s disease patients and 101 age-matched controls and measured gait characteristics during a 4x10 meter walk at the subjects’ preferred speed. To determine intraindividual changes in gait, we monitored the gait characteristics of 63 patients longitudinally. Cross-sectional analysis revealed distinct spatiotemporal gait parameter differences reflecting typical Parkinson’s disease gait characteristics including short steps, shuffling gait, and postural instability specific for different disease stages and levels of motor impairment. The longitudinal analysis revealed that gait parameters were sensitive to changes by mirroring the progressive nature of Parkinson’s disease and corresponded to physician ratings. Taken together, we successfully show that wearable sensor-based gait analysis reaches clinical applicability providing a high biomechanical resolution for gait impairment in Parkinson’s disease. These data demonstrate the feasibility and applicability of objective wearable sensor-based gait measurement in Parkinson’s disease reaching high technological readiness levels for both, large scale clinical studies and individual patient care. PMID:29020012

  3. A Wearable Magneto-Inertial System for Gait Analysis (H-Gait): Validation on Normal Weight and Overweight/Obese Young Healthy Adults

    PubMed Central

    Gastaldi, Laura; Rosso, Valeria; Knaflitz, Marco; Tadano, Shigeru

    2017-01-01

    Background: Wearable magneto-inertial sensors are being increasingly used to obtain human motion measurements out of the lab, although their performance in applications requiring high accuracy, such as gait analysis, are still a subject of debate. The aim of this work was to validate a gait analysis system (H-Gait) based on magneto-inertial sensors, both in normal weight (NW) and overweight/obese (OW) subjects. The validation is performed against a reference multichannel recording system (STEP32), providing direct measurements of gait timings (through foot-switches) and joint angles in the sagittal plane (through electrogoniometers). Methods: Twenty-two young male subjects were recruited for the study (12 NW, 10 OW). After positioning body-fixed sensors of both systems, each subject was asked to walk, at a self-selected speed, over a 14-m straight path for 12 trials. Gait signals were recorded, at the same time, with the two systems. Spatio-temporal parameters, ankle, knee, and hip joint kinematics were extracted analyzing an average of 89 ± 13 gait cycles from each lower limb. Intraclass correlation coefficient and Bland-Altmann plots were used to compare H-Gait and STEP32 measurements. Changes in gait parameters and joint kinematics of OW with respect NW were also evaluated. Results: The two systems were highly consistent for cadence, while a lower agreement was found for the other spatio-temporal parameters. Ankle and knee joint kinematics is overall comparable. Joint ROMs values were slightly lower for H-Gait with respect to STEP32 for the ankle (by 1.9° for NW, and 1.6° for OW) and for the knee (by 4.1° for NW, and 1.8° for OW). More evident differences were found for hip joint, with ROMs values higher for H-Gait (by 6.8° for NW, and 9.5° for OW). NW and OW showed significant differences considering STEP32 (p = 0.0004), but not H-Gait (p = 0.06). In particular, overweight/obese subjects showed a higher cadence (55.0 vs. 52.3 strides/min) and a lower hip ROM (23.0° vs. 27.3°) than normal weight subjects. Conclusions: The two systems can be considered interchangeable for what concerns joint kinematics, except for the hip, where discrepancies were evidenced. Differences between normal and overweight/obese subjects were statistically significant using STEP32. The same tendency was observed using H-Gait. PMID:29065485

  4. A method to simulate motor control strategies to recover from perturbations: application to a stumble recovery during gait.

    PubMed

    Forner-Cordero, Arturo; Ackermann, Marko; de Lima Freitas, Mateus

    2011-01-01

    Perturbations during human gait such as a trip or a slip can result in a fall, especially among frail populations such as the elderly. In order to recover from a trip or a stumble during gait, humans perform different types of recovery strategies. It is very useful to uncover the mechanisms of the recovery to improve training methods for populations at risk of falling. Moreover, human recovery strategies could be applied to implement controllers for bipedal robot walker, as an application of biomimetic design. A biomechanical model of the response to a trip during gait might uncover the control mechanisms underlying the different recovery strategies and the adaptation of the responses found during the execution of successive perturbation trials. This paper introduces a model of stumble in the multibody system framework. This model is used to assess different feedforward strategies to recover from a trip. First of all, normal gait patterns for the musculoskeletal system model are obtained by solving an optimal control problem. Secondly, the reference gait is perturbed by the application of forces on the swinging foot in different ways: as an instantaneous inelastic collision of the foot with an obstacle, as an impulsive horizontal force or using a force curve measured experimentally during gait perturbation experiments. The influence of the type of perturbation, the timing of the collision with respect to the gait cycle, as well as of the coefficient of restitution was investigated previously. Finally, in order to test the effects of different muscle excitation levels on the initial phases of the recovery response, several muscle excitations were added to selected muscles of the legs, thus providing a simulation of the recovery reactions. These results pave the way for future analysis and modeling of the control mechanisms of gait.

  5. A mechanical energy analysis of gait initiation

    NASA Technical Reports Server (NTRS)

    Miller, C. A.; Verstraete, M. C.

    1999-01-01

    The analysis of gait initiation (the transient state between standing and walking) is an important diagnostic tool to study pathologic gait and to evaluate prosthetic devices. While past studies have quantified mechanical energy of the body during steady-state gait, to date no one has computed the mechanical energy of the body during gait initiation. In this study, gait initiation in seven normal male subjects was studied using a mechanical energy analysis to compute total body energy. The data showed three separate states: quiet standing, gait initiation, and steady-state gait. During gait initiation, the trends in the energy data for the individual segments were similar to those seen during steady-state gait (and in Winter DA, Quanbury AO, Reimer GD. Analysis of instantaneous energy of normal gait. J Biochem 1976;9:253-257), but diminished in amplitude. However, these amplitudes increased to those seen in steady-state during the gait initiation event (GIE), with the greatest increase occurring in the second step due to the push-off of the foundation leg. The baseline level of mechanical energy was due to the potential energy of the individual segments, while the cyclic nature of the data was indicative of the kinetic energy of the particular leg in swing phase during that step. The data presented showed differences in energy trends during gait initiation from those of steady state, thereby demonstrating the importance of this event in the study of locomotion.

  6. The effect of mirror therapy integrating functional electrical stimulation on the gait of stroke patients.

    PubMed

    Ji, Sang-Goo; Cha, Hyun-Gyu; Kim, Myoung-Kwon; Lee, Chang-Ryeol

    2014-04-01

    [Purpose] The aim of the present study was to examine whether mirror therapy in conjunction with FES in stroke patients can improve gait ability. [Subjects] This study was conducted with 30 subjects who were diagnosed with hemiparesis due to stroke. [Methods] Experimental group I contained 10 subjects who received mirror therapy in conjunction with functional electrical stimulation, experimental group II contained 10 subjects who received mirror therapy, and the control group contained 10 subjects who received a sham therapy. A gait analysis was performed using a three-dimensional motion capture system, which was a real-time tracking device that delivers data in an infrared mode via reflective markers using six cameras. [Results] The results showed a significant difference in gait velocity between groups after the experiment, and post hoc analysis revealed significant differences between experimental group I and the control group and between experimental group II and the control group, respectively. There were also significant differences in step length and stride length between the groups after the experiment, and post hoc analysis revealed significant differences between experimental group I and control group. [Conclusion] The present study showed that mirror therapy in conjunction with FES is more effective for improving gait ability than mirror therapy alone.

  7. The Gait Disorder in Downbeat Nystagmus Syndrome

    PubMed Central

    Schniepp, Roman; Wuehr, Max; Huth, Sabrina; Pradhan, Cauchy; Schlick, Cornelia; Brandt, Thomas; Jahn, Klaus

    2014-01-01

    Background Downbeat nystagmus (DBN) is a common form of acquired fixation nystagmus with key symptoms of oscillopsia and gait disturbance. Gait disturbance could be a result of impaired visual feedback due to the involuntary ocular oscillations. Alternatively, a malfunction of cerebellar locomotor control might be involved, since DBN is considered a vestibulocerebellar disorder. Methods Investigation of walking in 50 DBN patients (age 72±11 years, 23 females) and 50 healthy controls (HS) (age 70±11 years, 23 females) using a pressure sensitive carpet (GAITRite). The patient cohort comprised subjects with only ocular motor signs (DBN) and subjects with an additional limb ataxia (DBNCA). Gait investigation comprised different walking speeds and walking with eyes closed. Results In DBN, gait velocity was reduced (p<0.001) with a reduced stride length (p<0.001), increased base of support (p<0.050), and increased double support (p<0.001). Walking with eyes closed led to significant gait changes in both HS and DBN. These changes were more pronounced in DBN patients (p<0.001). Speed-dependency of gait variability revealed significant differences between the subgroups of DBN and DBNCA (p<0.050). Conclusions (I) Impaired visual control caused by involuntary ocular oscillations cannot sufficiently explain the gait disorder. (II) The gait of patients with DBN is impaired in a speed dependent manner. (III) Analysis of gait variability allows distinguishing DBN from DBNCA: Patients with pure DBN show a speed dependency of gait variability similar to that of patients with afferent vestibular deficits. In DBNCA, gait variability resembles the pattern found in cerebellar ataxia. PMID:25140517

  8. Gait and Cognition in Parkinson's Disease: Cognitive Impairment Is Inadequately Reflected by Gait Performance during Dual Task.

    PubMed

    Gaßner, Heiko; Marxreiter, Franz; Steib, Simon; Kohl, Zacharias; Schlachetzki, Johannes C M; Adler, Werner; Eskofier, Bjoern M; Pfeifer, Klaus; Winkler, Jürgen; Klucken, Jochen

    2017-01-01

    Cognitive and gait deficits are common symptoms in Parkinson's disease (PD). Motor-cognitive dual tasks (DTs) are used to explore the interplay between gait and cognition. However, it is unclear if DT gait performance is indicative for cognitive impairment. Therefore, the aim of this study was to investigate if cognitive deficits are reflected by DT costs of spatiotemporal gait parameters. Cognitive function, single task (ST) and DT gait performance were investigated in 67 PD patients. Cognition was assessed by the Montreal Cognitive Assessment (MoCA) followed by a standardized, sensor-based gait test and the identical gait test while subtracting serial 3's. Cognitive impairment was defined by a MoCA score <26. DT costs in gait parameters [(DT - ST)/ST × 100] were calculated as a measure of DT effect on gait. Correlation analysis was used to evaluate the association between MoCA performance and gait parameters. In a linear regression model, DT gait costs and clinical confounders (age, gender, disease duration, motor impairment, medication, and depression) were correlated to cognitive performance. In a subgroup analysis, we compared matched groups of cognitively impaired and unimpaired PD patients regarding differences in ST, DT, and DT gait costs. Correlation analysis revealed weak correlations between MoCA score and DT costs of gait parameters ( r / r Sp  ≤ 0.3). DT costs of stride length, swing time variability, and maximum toe clearance (| r / r Sp | > 0.2) were included in a regression analysis. The parameters only explain 8% of the cognitive variance. In combination with clinical confounders, regression analysis showed that these gait parameters explained 30% of MoCA performance. Group comparison revealed strong DT effects within both groups (large effect sizes), but significant between-group effects in DT gait costs were not observed. These findings suggest that DT gait performance is not indicative for cognitive impairment in PD. DT effects on gait parameters were substantial in cognitively impaired and unimpaired patients, thereby potentially overlaying the effect of cognitive impairment on DT gait costs. Limits of the MoCA in detecting motor-function specific cognitive performance or variable individual response to the DT as influencing factors cannot be excluded. Therefore, DT gait parameters as marker for cognitive performance should be carefully interpreted in the clinical context.

  9. Newly Identified Gait Patterns in Patients With Multiple Sclerosis May Be Related to Push-off Quality.

    PubMed

    Kempen, Jiska C E; Doorenbosch, Caroline A M; Knol, Dirk L; de Groot, Vincent; Beckerman, Heleen

    2016-11-01

    Limited walking ability is an important problem for patients with multiple sclerosis. A better understanding of how gait impairments lead to limited walking ability may help to develop more targeted interventions. Although gait classifications are available in cerebral palsy and stroke, relevant knowledge in MS is scarce. The aims of this study were: (1) to identify distinctive gait patterns in patients with MS based on a combined evaluation of kinematics, gait features, and muscle activity during walking and (2) to determine the clinical relevance of these gait patterns. This was a cross-sectional study of 81 patients with MS of mild-to-moderate severity (Expanded Disability Status Scale [EDSS] median score=3.0, range=1.0-7.0) and an age range of 28 to 69 years. The patients participated in 2-dimensional video gait analysis, with concurrent measurement of surface electromyography and ground reaction forces. A score chart of 73 gait items was used to rate each gait analysis. A single rater performed the scoring. Latent class analysis was used to identify gait classes. Analysis of the 73 gait variables revealed that 9 variables could distinguish 3 clinically meaningful gait classes. The 9 variables were: (1) heel-rise in terminal stance, (2) push-off, (3) clearance in initial swing, (4) plantar-flexion position in mid-swing, (5) pelvic rotation, (6) arm-trunk movement, (7) activity of the gastrocnemius muscle in pre-swing, (8) M-wave, and (9) propulsive force. The EDSS score and gait speed worsened in ascending classes. Most participants had mild-to-moderate limitations in walking ability based on their EDSS scores, and the number of walkers who were severely limited was small. Based on a small set of 9 variables measured with 2-dimensional clinical gait analysis, patients with MS could be divided into 3 different gait classes. The gait variables are suggestive of insufficient ankle push-off. © 2016 American Physical Therapy Association.

  10. Gait analysis in children with cerebral palsy.

    PubMed

    Armand, Stéphane; Decoulon, Geraldo; Bonnefoy-Mazure, Alice

    2016-12-01

    Cerebral palsy (CP) children present complex and heterogeneous motor disorders that cause gait deviations.Clinical gait analysis (CGA) is needed to identify, understand and support the management of gait deviations in CP. CGA assesses a large amount of quantitative data concerning patients' gait characteristics, such as video, kinematics, kinetics, electromyography and plantar pressure data.Common gait deviations in CP can be grouped into the gait patterns of spastic hemiplegia (drop foot, equinus with different knee positions) and spastic diplegia (true equinus, jump, apparent equinus and crouch) to facilitate communication. However, gait deviations in CP tend to be a continuum of deviations rather than well delineated groups. To interpret CGA, it is necessary to link gait deviations to clinical impairments and to distinguish primary gait deviations from compensatory strategies.CGA does not tell us how to treat a CP patient, but can provide objective identification of gait deviations and further the understanding of gait deviations. Numerous treatment options are available to manage gait deviations in CP. Generally, treatments strive to limit secondary deformations, re-establish the lever arm function and preserve muscle strength.Additional roles of CGA are to better understand the effects of treatments on gait deviations. Cite this article: Armand S, Decoulon G, Bonnefoy-Mazure A. Gait analysis in children with cerebral palsy. EFORT Open Rev 2016;1:448-460. DOI: 10.1302/2058-5241.1.000052.

  11. Gait changes precede overt arthritis and strongly correlate with symptoms and histopathological events in pristane-induced arthritis

    PubMed Central

    2010-01-01

    Introduction Pristane-induced arthritis (PIA) in the rat has been described as an animal model of inflammatory arthritis which exhibits features similar to rheumatoid arthritis in humans, such as a chronic, destructive, and symmetrical involvement of peripheral joints. However, so far little is known about the earliest inflammatory events and their influence on locomotor behaviour during the course of PIA. To investigate this issue a detailed analysis of the pathologic changes occurring during the prodromal and early stages of PIA was performed. Methods Arthritis was induced in DA.rats by injection of 150 μl 2,6,10,4-tetramethyl-pentadecane (pristane) at the base of the tail and changes in locomotor behaviour of the affected paws were monitored using the CatWalk quantitative gait analysis system. The pathologic events occurring in the joints of pristane-injected animals were studied before onset, at onset, and during acute phase of arthritis by histological methods. Results Gait analysis revealed that changes in locomotion such as reduced paw print areas and stance phase time are already apparent before the onset of clinically discernible arthritis symptoms (erythema, paw swelling) and correlate with PIA scores. In agreement with these findings, inflammatory tenosynovitis could be observed by histology already before the onset of erythema and swelling of the respective paws. In the most heavily affected rats also irregularities in step sequence patterns occurred A kinetic analysis of clinical and histological findings demonstrated that gait changes precede the pathological changes occurring during the acute phase of pristane-induced arthritis. Conclusions Gait analysis allows for pinpointing the initial inflammatory changes in experimental arthritis models such as pristane-induced arthritis. Analysis of early clinically relevant symptoms in arthritis models may facilitate the search for novel therapeutics to interfere with pain, inflammation and joint destruction in patients suffering from inflammatory arthritis. PMID:20222952

  12. Balzac and human gait analysis.

    PubMed

    Collado-Vázquez, S; Carrillo, J M

    2015-05-01

    People have been interested in movement analysis in general, and gait analysis in particular, since ancient times. Aristotle, Hippocrates, Galen, Leonardo da Vinci and Honoré de Balzac all used observation to analyse the gait of human beings. The purpose of this study is to compare Honoré de Balzac's writings with a scientific analysis of human gait. Honoré de Balzac's Theory of walking and other works by that author referring to gait. Honoré de Balzac had an interest in gait analysis, as demonstrated by his descriptions of characters which often include references to their way of walking. He also wrote a treatise entitled Theory of walking (Théorie de la demarche) in which he employed his keen observation skills to define gait using a literary style. He stated that the walking process is divided into phases and listed the factors that influence gait, such as personality, mood, height, weight, profession and social class, and also provided a description of the correct way of walking. Balzac considered gait analysis to be very important and this is reflected in both his character descriptions and Theory of walking, his analytical observation of gait. In our own technology-dominated times, this serves as a reminder of the importance of observation. Copyright © 2011 Sociedad Española de Neurología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Effects of Robot-assisted Gait Training Combined with Functional Electrical Stimulation on Recovery of Locomotor Mobility in Chronic Stroke Patients: A Randomized Controlled Trial.

    PubMed

    Bae, Young-Hyeon; Ko, Young Jun; Chang, Won Hyuk; Lee, Ju Hyeok; Lee, Kyeong Bong; Park, Yoo Jung; Ha, Hyun Geun; Kim, Yun-Hee

    2014-12-01

    [Purpose] The purpose of the present study was to investigate the effects of robot-assisted gait training combined with functional electrical stimulation on locomotor recovery in patients with chronic stroke. [Subjects] The 20 subjects were randomly assigned into either an experimental group (n = 10) that received a combination of robot-assisted gait training and functional electrical stimulation on the ankle dorsiflexor of the affected side or a control group (n = 10) that received robot-assisted gait training only. [Methods] Both groups received the respective therapies for 30 min/day, 3 days/week for 5 weeks. The outcome was measured using the Modified Motor Assessment Scale (MMAS), Timed Up-and-Go Test (TUG), Berg Balance Scale (BBS), and gait parameters through gait analysis (Vicon 370 motion analysis system, Oxford Metrics Ltd., Oxford, UK). All the variables were measured before and after training. [Results] Step length and maximal knee extension were significantly greater than those before training in the experimental group only. Maximal Knee flexion showed a significant difference between the experimental and control groups. The MMAS, BBS, and TUG scores improved significantly after training compared with before training in both groups. [Conclusion] We suggest that the combination of robot-assisted gait training and functional electrical stimulation encourages patients to actively participate in training because it facilitates locomotor recovery without the risk of adverse effects.

  14. Gait Patterns in Hemiplegic Children with Cerebral Palsy: Comparison of Right and Left Hemiplegia

    ERIC Educational Resources Information Center

    Galli, Manuela; Cimolin, Veronica; Rigoldi, Chiara; Tenore, Nunzio; Albertini, Giorgio

    2010-01-01

    The aims of this study are to compare quantitatively the gait strategy of the right and left hemiplegic children with Cerebral Palsy (CP) using gait analysis. The gait strategy of 28 right hemiparetic CP (RHG) and 23 left hemiparetic CP (LHG) was compared using gait analysis (spatio-temporal and kinematic parameters) and considering the hemiplegic…

  15. Data series embedding and scale invariant statistics.

    PubMed

    Michieli, I; Medved, B; Ristov, S

    2010-06-01

    Data sequences acquired from bio-systems such as human gait data, heart rate interbeat data, or DNA sequences exhibit complex dynamics that is frequently described by a long-memory or power-law decay of autocorrelation function. One way of characterizing that dynamics is through scale invariant statistics or "fractal-like" behavior. For quantifying scale invariant parameters of physiological signals several methods have been proposed. Among them the most common are detrended fluctuation analysis, sample mean variance analyses, power spectral density analysis, R/S analysis, and recently in the realm of the multifractal approach, wavelet analysis. In this paper it is demonstrated that embedding the time series data in the high-dimensional pseudo-phase space reveals scale invariant statistics in the simple fashion. The procedure is applied on different stride interval data sets from human gait measurements time series (Physio-Bank data library). Results show that introduced mapping adequately separates long-memory from random behavior. Smaller gait data sets were analyzed and scale-free trends for limited scale intervals were successfully detected. The method was verified on artificially produced time series with known scaling behavior and with the varying content of noise. The possibility for the method to falsely detect long-range dependence in the artificially generated short range dependence series was investigated. (c) 2009 Elsevier B.V. All rights reserved.

  16. Correlation between static radiographic measurements and intersegmental angular measurements during gait using a multisegment foot model.

    PubMed

    Lee, Dong Yeon; Seo, Sang Gyo; Kim, Eo Jin; Kim, Sung Ju; Lee, Kyoung Min; Farber, Daniel C; Chung, Chin Youb; Choi, In Ho

    2015-01-01

    Radiographic examination is a widely used evaluation method in the orthopedic clinic. However, conventional radiography alone does not reflect the dynamic changes between foot and ankle segments during gait. Multiple 3-dimensional multisegment foot models (3D MFMs) have been introduced to evaluate intersegmental motion of the foot. In this study, we evaluated the correlation between static radiographic indices and intersegmental foot motion indices. One hundred twenty-five females were tested. Static radiographs of full-leg and anteroposterior (AP) and lateral foot views were performed. For hindfoot evaluation, we measured the AP tibiotalar angle (TiTA), talar tilt (TT), calcaneal pitch, lateral tibiocalcaneal angle, and lateral talcocalcaneal angle. For the midfoot segment, naviculocuboid overlap and talonavicular coverage angle were calculated. AP and lateral talo-first metatarsal angles and metatarsal stacking angle (MSA) were measured to assess the forefoot. Hallux valgus angle (HVA) and hallux interphalangeal angle were measured. In gait analysis by 3D MFM, intersegmental angle (ISA) measurements of each segment (hallux, forefoot, hindfoot, arch) were recorded. ISAs at midstance phase were most highly correlated with radiography. Significant correlations were observed between ISA measurements using MFM and static radiographic measurements in the same segment. In the hindfoot, coronal plane ISA was correlated with AP TiTA (P < .001) and TT (P = .018). In the hallux, HVA was strongly correlated with transverse ISA of the hallux (P < .001). The segmental foot motion indices at midstance phase during gait measured by 3D MFM gait analysis were correlated with the conventional radiographic indices. The observed correlation between MFM measurements at midstance phase during gait and static radiographic measurements supports the fundamental basis for the use of MFM in analysis of dynamic motion of foot segment during gait. © The Author(s) 2014.

  17. Quadrupedal rodent gait compensations in a low dose monoiodoacetate model of osteoarthritis.

    PubMed

    Lakes, Emily H; Allen, Kyle D

    2018-06-01

    Rodent gait analysis provides robust, quantitative results for preclinical musculoskeletal and neurological models. In prior work, surgical models of osteoarthritis have been found to result in a hind limb shuffle-stepping gait compensation, while a high dose monoiodoacetate (MIA, 3 mg) model resulted in a hind limb antalgic gait. However, it is unknown whether the antalgic gait caused by MIA is associated with severity of degeneration from the high dosage or the whole-joint degeneration associated with glycolysis inhibition. This study evaluates rodent gait changes resulting from a low dose, 1 mg unilateral intra-articular injection of MIA compared to saline injected and naïve rats. Spatiotemporal and dynamic gait parameters were collected from a total of 42 male Lewis rats spread across 3 time points: 1, 2, and 4 weeks post-injection. To provide a detailed analysis of this low dose MIA model, gait analysis was used to uniquely quantify both fore and hind limb gait parameters. Our data indicate that 1 mg of MIA caused relatively minor degeneration and a shuffle-step gait compensation, similar to the compensation observed in prior surgical models. These data from a 1 mg MIA model show a different gait compensation compared to a previously studied 3 mg model. This 1 mg MIA model resulted in gait compensations more similar to a previously studied surgical model of osteoarthritis. Additionally, this study provides detailed 4 limb analysis of rodent gait that includes spatiotemporal and dynamic data from the same gait trial. These data highlight the importance of measuring dynamic data in combination with spatiotemporal data, since compensatory gait patterns may not be captured by spatial, temporal, or dynamic characterizations alone. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Gait Recognition Using Wearable Motion Recording Sensors

    NASA Astrophysics Data System (ADS)

    Gafurov, Davrondzhon; Snekkenes, Einar

    2009-12-01

    This paper presents an alternative approach, where gait is collected by the sensors attached to the person's body. Such wearable sensors record motion (e.g. acceleration) of the body parts during walking. The recorded motion signals are then investigated for person recognition purposes. We analyzed acceleration signals from the foot, hip, pocket and arm. Applying various methods, the best EER obtained for foot-, pocket-, arm- and hip- based user authentication were 5%, 7%, 10% and 13%, respectively. Furthermore, we present the results of our analysis on security assessment of gait. Studying gait-based user authentication (in case of hip motion) under three attack scenarios, we revealed that a minimal effort mimicking does not help to improve the acceptance chances of impostors. However, impostors who know their closest person in the database or the genders of the users can be a threat to gait-based authentication. We also provide some new insights toward the uniqueness of gait in case of foot motion. In particular, we revealed the following: a sideway motion of the foot provides the most discrimination, compared to an up-down or forward-backward directions; and different segments of the gait cycle provide different level of discrimination.

  19. Intraindividual Variability in Executive Functions but Not Speed of Processing or Conflict Resolution Predicts Performance Differences in Gait Speed in Older Adults

    PubMed Central

    Mahoney, Jeannette; Verghese, Joe

    2014-01-01

    Background. The relationship between executive functions (EF) and gait speed is well established. However, with the exception of dual tasking, the key components of EF that predict differences in gait performance have not been determined. Therefore, the current study was designed to determine whether processing speed, conflict resolution, and intraindividual variability in EF predicted variance in gait performance in single- and dual-task conditions. Methods. Participants were 234 nondemented older adults (mean age 76.48 years; 55% women) enrolled in a community-based cohort study. Gait speed was assessed using an instrumented walkway during single- and dual-task conditions. The flanker task was used to assess EF. Results. Results from the linear mixed effects model showed that (a) dual-task interference caused a significant dual-task cost in gait speed (estimate = 35.99; 95% CI = 33.19–38.80) and (b) of the cognitive predictors, only intraindividual variability was associated with gait speed (estimate = −.606; 95% CI = −1.11 to −.10). In unadjusted analyses, the three EF measures were related to gait speed in single- and dual-task conditions. However, in fully adjusted linear regression analysis, only intraindividual variability predicted performance differences in gait speed during dual tasking (B = −.901; 95% CI = −1.557 to −.245). Conclusion. Among the three EF measures assessed, intraindividual variability but not speed of processing or conflict resolution predicted performance differences in gait speed. PMID:24285744

  20. New Lower-Limb Gait Asymmetry Indices Based on a Depth Camera

    PubMed Central

    Auvinet, Edouard; Multon, Franck; Meunier, Jean

    2015-01-01

    Background: Various asymmetry indices have been proposed to compare the spatiotemporal, kinematic and kinetic parameters of lower limbs during the gait cycle. However, these indices rely on gait measurement systems that are costly and generally require manual examination, calibration procedures and the precise placement of sensors/markers on the body of the patient. Methods: To overcome these issues, this paper proposes a new asymmetry index, which uses an inexpensive, easy-to-use and markerless depth camera (Microsoft Kinect™) output. This asymmetry index directly uses depth images provided by the Kinect™ without requiring joint localization. It is based on the longitudinal spatial difference between lower-limb movements during the gait cycle. To evaluate the relevance of this index, fifteen healthy subjects were tested on a treadmill walking normally and then via an artificially-induced gait asymmetry with a thick sole placed under one shoe. The gait movement was simultaneously recorded using a Kinect™ placed in front of the subject and a motion capture system. Results: The proposed longitudinal index distinguished asymmetrical gait (p < 0.001), while other symmetry indices based on spatiotemporal gait parameters failed using such Kinect™ skeleton measurements. Moreover, the correlation coefficient between this index measured by Kinect™ and the ground truth of this index measured by motion capture is 0.968. Conclusion: This gait asymmetry index measured with a Kinect™ is low cost, easy to use and is a promising development for clinical gait analysis. PMID:25719863

  1. Good agreement between smart device and inertial sensor-based gait parameters during a 6-min walk.

    PubMed

    Proessl, F; Swanson, C W; Rudroff, T; Fling, B W; Tracy, B L

    2018-05-28

    Traditional laboratory-based kinetic and kinematic gait analyses are expensive, time-intensive, and impractical for clinical settings. Inertial sensors have gained popularity in gait analysis research and more recently smart devices have been employed to provide quantification of gait. However, no study to date has investigated the agreement between smart device and inertial sensor-based gait parameters during prolonged walking. Compare spatiotemporal gait metrics measured with a smart device versus previously validated inertial sensors. Twenty neurologically healthy young adults (7 women; age: 25.0 ± 3.7 years; BMI: 23.4 ± 2.9 kg/m 2 ) performed a 6-min walk test (6MWT) wearing inertial sensors and smart devices to record stride duration, stride length, cadence, and gait speed. Pearson correlations were used to assess associations between spatiotemporal measures from the two devices and agreement between the two methods was assessed with Bland-Altman plots and limits of agreement. All spatiotemporal gait metrics (stride duration, cadence, stride length and gait speed) showed strong (r>0.9) associations and good agreement between the two devices. Smart devices are capable of accurately reflecting many of the spatiotemporal gait metrics of inertial sensors. As the smart devices also accurately reflected individual leg output, future studies may apply this analytical strategy to clinical populations, to identify hallmarks of disability status and disease progression in a more ecologically valid environment. Copyright © 2018. Published by Elsevier B.V.

  2. The interest of gait markers in the identification of subgroups among fibromyalgia patients.

    PubMed

    Auvinet, Bernard; Chaleil, Denis; Cabane, Jean; Dumolard, Anne; Hatron, Pierre; Juvin, Robert; Lanteri-Minet, Michel; Mainguy, Yves; Negre-Pages, Laurence; Pillard, Fabien; Riviere, Daniel; Maugars, Yves-Michel

    2011-11-11

    Fibromyalgia (FM) is a heterogeneous syndrome and its classification into subgroups calls for broad-based discussion. FM subgrouping, which aims to adapt treatment according to different subgroups, relies in part, on psychological and cognitive dysfunctions. Since motor control of gait is closely related to cognitive function, we hypothesized that gait markers could be of interest in the identification of FM patients' subgroups. This controlled study aimed at characterizing gait disorders in FM, and subgrouping FM patients according to gait markers such as stride frequency (SF), stride regularity (SR), and cranio-caudal power (CCP) which measures kinesia. A multicentre, observational open trial enrolled patients with primary FM (44.1 ± 8.1 y), and matched controls (44.1 ± 7.3 y). Outcome measurements and gait analyses were available for 52 pairs. A 3-step statistical analysis was carried out. A preliminary single blind analysis using k-means cluster was performed as an initial validation of gait markers. Then in order to quantify FM patients according to psychometric and gait variables an open descriptive analysis comparing patients and controls were made, and correlations between gait variables and main outcomes were calculated. Finally using cluster analysis, we described subgroups for each gait variable and looked for significant differences in self-reported assessments. SF was the most discriminating gait variable (73% of patients and controls). SF, SR, and CCP were different between patients and controls. There was a non-significant association between SF, FIQ and physical components from Short-Form 36 (p = 0.06). SR was correlated to FIQ (p = 0.01) and catastrophizing (p = 0.05) while CCP was correlated to pain (p = 0.01). The SF cluster identified 3 subgroups with a particular one characterized by normal SF, low pain, high activity and hyperkinesia. The SR cluster identified 2 distinct subgroups: the one with a reduced SR was distinguished by high FIQ, poor coping and altered affective status. Gait analysis may provide additional information in the identification of subgroups among fibromyalgia patients. Gait analysis provided relevant information about physical and cognitive status, and pain behavior. Further studies are needed to better understand gait analysis implications in FM.

  3. A PDF-based classification of gait cadence patterns in patients with amyotrophic lateral sclerosis.

    PubMed

    Wu, Yunfeng; Ng, Sin Chun

    2010-01-01

    Amyotrophic lateral sclerosis (ALS) is a type of neurological disease due to the degeneration of motor neurons. During the course of such a progressive disease, it would be difficult for ALS patients to regulate normal locomotion, so that the gait stability becomes perturbed. This paper presents a pilot statistical study on the gait cadence (or stride interval) in ALS, based on the statistical analysis method. The probability density functions (PDFs) of stride interval were first estimated with the nonparametric Parzen-window method. We computed the mean of the left-foot stride interval and the modified Kullback-Leibler divergence (MKLD) from the PDFs estimated. The analysis results suggested that both of these two statistical parameters were significantly altered in ALS, and the least-squares support vector machine (LS-SVM) may effectively distinguish the stride patterns between the ALS patients and healthy controls, with an accurate rate of 82.8% and an area of 0.87 under the receiver operating characteristic curve.

  4. Gait disorders in the elderly and dual task gait analysis: a new approach for identifying motor phenotypes.

    PubMed

    Auvinet, Bernard; Touzard, Claude; Montestruc, François; Delafond, Arnaud; Goeb, Vincent

    2017-01-31

    Gait disorders and gait analysis under single and dual-task conditions are topics of great interest, but very few studies have looked for the relevance of gait analysis under dual-task conditions in elderly people on the basis of a clinical approach. An observational study including 103 patients (mean age 76.3 ± 7.2, women 56%) suffering from gait disorders or memory impairment was conducted. Gait analysis under dual-task conditions was carried out for all patients. Brain MRI was performed in the absence of contra-indications. Three main gait variables were measured: walking speed, stride frequency, and stride regularity. For each gait variable, the dual task cost was computed and a quartile analysis was obtained. Nonparametric tests were used for all the comparisons (Wilcoxon, Kruskal-Wallis, Fisher or Chi 2 tests). Four clinical subgroups were identified: gait instability (45%), recurrent falls (29%), memory impairment (18%), and cautious gait (8%). The biomechanical severity of these subgroups was ordered according to walking speed and stride regularity under both conditions, from least to most serious as follows: memory impairment, gait instability, recurrent falls, cautious gait (p < 0.01 for walking speed, p = 0.05 for stride regularity). According to the established diagnoses of gait disorders, 5 main pathological subgroups were identified (musculoskeletal diseases (n = 11), vestibular diseases (n = 6), mild cognitive impairment (n = 24), central nervous system pathologies, (n = 51), and without diagnosis (n = 8)). The dual task cost for walking speed, stride frequency and stride regularity were different among these subgroups (p < 0.01). The subgroups mild cognitive impairment and central nervous system pathologies both showed together a higher dual task cost for each variable compared to the other subgroups combined (p = 0.01). The quartile analysis of dual task cost for stride frequency and stride regularity allowed the identification of 3 motor phenotypes (p < 0.01), without any difference for white matter hyperintensities, but with an increased Scheltens score from the first to the third motor phenotype (p = 0.05). Gait analysis under dual-task conditions in elderly people suffering from gait disorders or memory impairment is of great value in assessing the severity of gait disorders, differentiating between peripheral pathologies and central nervous system pathologies, and identifying motor phenotypes. Correlations between motor phenotypes and brain imaging require further studies.

  5. Kinematic Analysis of Gait Following Intra-articular Corticosteroid Injection into the Knee Joint with an Acute Exacerbation of Arthritis

    PubMed Central

    Mehta, Saurabh; Szturm, Tony; El-Gabalawy, Hani S.

    2011-01-01

    ABSTRACT Purpose: The objective of this study was to examine the effects of intra-articular corticosteroid injection (ICI) on ipsilateral knee flexion/extension, ankle dorsiflexion/plantarflexion (DF/PF), and hip abduction/adduction (abd/add) during stance phase in people with an acute exacerbation of rheumatoid arthritis (RA) of the knee joint. The study also assessed the effects of ICI on spatiotemporal parameters of gait and functional status in this group. Methods: Nine people with an exacerbation of RA of the knee were recruited. Kinematic and spatiotemporal gait parameters were obtained for each participant. Knee-related functional status was assessed using the Knee injury and Osteoarthritis Outcome Score (KOOS). Spatiotemporal gait parameters and joint angles (knee flexion, ankle DF/PF, hip abd/add) of the affected side were compared pre- and post-ICI. Results: Data for eight people were available for analysis. Median values for knee flexion and ankle PF increased significantly following ICI. Gait parameters of cadence, velocity, bilateral stride length, bilateral step length, step width, double-support percentage, and step time on the affected side also showed improvement. Pain and knee-related functional status as measured by the KOOS showed improvement. Conclusions: This study demonstrated a beneficial short-term effect of ICI on knee-joint movements, gait parameters, and knee-related functional status in people with acute exacerbation of RA of the knee. PMID:22942516

  6. A gait stability investigation into FES-assisted paraplegic walking based on the walker tipping index.

    PubMed

    Ming, Dong; Bai, Yanru; Liu, Xiuyun; Qi, Hongzhi; Cheng, Longlong; Wan, Baikun; Hu, Yong; Wong, Yatwa; Luk, Keith D K; Leong, John C Y

    2009-12-01

    The gait outcome measures used in clinical trials of paraplegic locomotor training determine the effectiveness of improved walking function assisted by the functional electrical stimulation (FES) system. Focused on kinematic, kinetic or physiological changes of paraplegic patients, traditional methods cannot quantify the walking stability or identify the unstable factors of gait in real time. Up until now, the published studies on dynamic gait stability for the effective use of FES have been limited. In this paper, the walker tipping index (WTI) was used to analyze and process gait stability in FES-assisted paraplegic walking. The main instrument was a specialized walker dynamometer system based on a multi-channel strain-gauge bridge network fixed on the frame of the walker. This system collected force information for the handle reaction vector between the patient's upper extremities and the walker during the walking process; the information was then converted into walker tipping index data, which is an evaluation indicator of the patient's walking stability. To demonstrate the potential usefulness of WTI in gait analysis, a preliminary clinical trial was conducted with seven paraplegic patients who were undergoing FES-assisted walking training and seven normal control subjects. The gait stability levels were quantified for these patients under different stimulation patterns and controls under normal walking with knee-immobilization through WTI analysis. The results showed that the walking stability in the FES-assisted paraplegic group was worse than that in the control subject group, with the primary concern being in the anterior-posterior plane. This new technique is practical for distinguishing useful gait information from the viewpoint of stability, and may be further applied in FES-assisted paraplegic walking rehabilitation.

  7. Meaningful improvement in gait speed in hip fracture recovery.

    PubMed

    Alley, Dawn E; Hicks, Gregory E; Shardell, Michelle; Hawkes, William; Miller, Ram; Craik, Rebecca L; Mangione, Kathleen K; Orwig, Denise; Hochberg, Marc; Resnick, Barbara; Magaziner, Jay

    2011-09-01

    To estimate meaningful improvements in gait speed observed during recovery from hip fracture and to evaluate the sensitivity and specificity of gait speed changes in detecting change in self-reported mobility. Secondary longitudinal data analysis from two randomized controlled trials Twelve hospitals in the Baltimore, Maryland, area. Two hundred seventeen women admitted with hip fracture. Usual gait speed and self-reported mobility (ability to walk 1 block and climb 1 flight of stairs) measured 2 and 12 months after fracture. Effect size-based estimates of meaningful differences were 0.03 for small differences and 0.09 for substantial differences. Depending on the anchor (stairs vs walking) and method (mean difference vs regression), anchor-based estimates ranged from 0.10 to 0.17 m/s for small meaningful improvements and 0.17 to 0.26 m/s for substantial meaningful improvement. Optimal gait speed cutpoints yielded low sensitivity (0.39-0.62) and specificity (0.57-0.76) for improvements in self-reported mobility. Results from this sample of women recovering from hip fracture provide only limited support for the 0.10-m/s cut point for substantial meaningful change previously identified in community-dwelling older adults experiencing declines in walking abilities. Anchor-based estimates and cut points derived from receiver operating characteristic curve analysis suggest that greater improvements in gait speed may be required for substantial perceived mobility improvement in female hip fracture patients. Furthermore, gait speed change performed poorly in discriminating change in self-reported mobility. Estimates of meaningful change in gait speed may differ based on the direction of change (improvement vs decline) or between patient populations. © 2011, Copyright the Authors. Journal compilation © 2011, The American Geriatrics Society.

  8. Meaningful Improvement in Gait Speed in Hip Fracture Recovery

    PubMed Central

    Alley, Dawn E.; Hicks, Gregory E.; Shardell, Michelle; Hawkes, William; Miller, Ram; Craik, Rebecca L.; Mangione, Kathleen K.; Orwig, Denise; Hochberg, Marc; Resnick, Barbara; Magaziner, Jay

    2011-01-01

    OBJECTIVES To estimate meaningful improvements in gait speed observed during recovery from hip fracture and to evaluate the sensitivity and specificity of gait speed changes in detecting change in self-reported mobility. DESIGN Secondary longitudinal data analysis from two randomized controlled trials SETTING Twelve hospitals in the Baltimore, Maryland, area. PARTICIPANTS Two hundred seventeen women admitted with hip fracture. MEASUREMENTS Usual gait speed and self-reported mobility (ability to walk 1 block and climb 1 flight of stairs) measured 2 and 12 months after fracture. RESULTS Effect size–based estimates of meaningful differences were 0.03 for small differences and 0.09 for substantial differences. Depending on the anchor (stairs vs walking) and method (mean difference vs regression), anchor-based estimates ranged from 0.10 to 0.17 m/s for small meaningful improvements and 0.17 to 0.26 m/s for substantial meaningful improvement. Optimal gait speed cut-points yielded low sensitivity (0.39–0.62) and specificity (0.57–0.76) for improvements in self-reported mobility. CONCLUSION Results from this sample of women recovering from hip fracture provide only limited support for the 0.10-m/s cut point for substantial meaningful change previously identified in community-dwelling older adults experiencing declines in walking abilities. Anchor-based estimates and cut points derived from receiver operating characteristic curve analysis suggest that greater improvements in gait speed may be required for substantial perceived mobility improvement in female hip fracture patients. Furthermore, gait speed change performed poorly in discriminating change in self-reported mobility. Estimates of meaningful change in gait speed may differ based on the direction of change (improvement vs decline) or between patient populations. PMID:21883109

  9. A gait stability investigation into FES-assisted paraplegic walking based on the walker tipping index

    NASA Astrophysics Data System (ADS)

    Ming, Dong; Bai, Yanru; Liu, Xiuyun; Qi, Hongzhi; Cheng, Longlong; Wan, Baikun; Hu, Yong; Wong, Yatwa; Luk, Keith D. K.; Leong, John C. Y.

    2009-12-01

    The gait outcome measures used in clinical trials of paraplegic locomotor training determine the effectiveness of improved walking function assisted by the functional electrical stimulation (FES) system. Focused on kinematic, kinetic or physiological changes of paraplegic patients, traditional methods cannot quantify the walking stability or identify the unstable factors of gait in real time. Up until now, the published studies on dynamic gait stability for the effective use of FES have been limited. In this paper, the walker tipping index (WTI) was used to analyze and process gait stability in FES-assisted paraplegic walking. The main instrument was a specialized walker dynamometer system based on a multi-channel strain-gauge bridge network fixed on the frame of the walker. This system collected force information for the handle reaction vector between the patient's upper extremities and the walker during the walking process; the information was then converted into walker tipping index data, which is an evaluation indicator of the patient's walking stability. To demonstrate the potential usefulness of WTI in gait analysis, a preliminary clinical trial was conducted with seven paraplegic patients who were undergoing FES-assisted walking training and seven normal control subjects. The gait stability levels were quantified for these patients under different stimulation patterns and controls under normal walking with knee-immobilization through WTI analysis. The results showed that the walking stability in the FES-assisted paraplegic group was worse than that in the control subject group, with the primary concern being in the anterior-posterior plane. This new technique is practical for distinguishing useful gait information from the viewpoint of stability, and may be further applied in FES-assisted paraplegic walking rehabilitation.

  10. Changes of kinematics parameters of pelvis during walking under the influence of means facilitates treatment of cerebral palsied children.

    PubMed

    Czupryna, Krzysztof; Nowotny, Janusz

    2012-01-01

    Physiological human gait is characterized by tree-dimensional pelvis movements, which make that gait is smooth and does not require excessive energy expenditure. In children with cerebral palsy determinants of the pelvis may be affected, mainly due to pathological afferent synergisms. Therefore many specialists is looking for ways to improve this situation. The aim of this study was to verify whether the use of botulinium toxin or inhibitive casts affects the kinematic parameters of the pelvis during the gait of children with hemiparetic form of cerebral palsy. The study involved 34 hemiparetic children with cerebral palsy aged 7-14 years who reached the capacity of walking. All were improving by neurodevelop-mental treatment according to NDT-Bobath method. Two groups were created. In the first group inhibiting casting was used in 16 children. In the second group botulinium toxin was injected in 18 children. Gait analysis was performed before and after using those type of treatment. Ultrasonic CMS-HS system (Zebris) was used for three dimensional gait analysis. Despite of the characteristic for hemiplegic gait pattern asymmetry, various ab-normalities of pelvis kinematic parameters were observed. Gait symmetry was improved aafter the treatment. Using inhibiting casts also improved kinematic parameters of the pelvis, especially in those children who are found deficit of decreasing and rotation of the pelvis. 1) The use of Btx-A or inhibitive casts results in improving temporal- spatial parameters of gait of cerebral palsied children with hemiparesis. 2) The improvement of kinematic pelvis parameters are obtained through the use of inhibitive casts, while the use of Btx-A does not have a significant impact on them.

  11. Changes of kinematics parameters of pelvis during walking under the influence of means facilitates treatment of cerebral palsied children.

    PubMed

    Czupryna, Krzysztof; Nowotny, Janusz

    2012-01-01

    Physiological human gait is characterized by changes of foot and knee angle that make the gait efficient and not require excessive energy expenditure. In cerebral palsied children, the foot-knee relationship is disturbed by pathological synergies. Therefore, ways to improve this situation are sought. The aim of the study was to verify whether and how well the use of botulinum toxin or inhibitive casts alters the behaviour of the foot-knee complex in cerebral palsy gait. The study involved 34 hemiparetic children with cerebral palsy aged 7-14 years who were able to walk unassisted. Neurodevelopmental treatment according to the NDT-Bobath method was given to all the children. Two groups were formed. In the first group of 16 children, inhibitive castings were used. The second group of 18 children received Btx-A injections. Gait analysis was performed at baseline and one month after administering these additional treatments. The CMS-HS ultrasonic system (Zebris) was used for three dimensional gait analysis. Apart from the pattern asymmetry characteristic of a hemiplegic gait, various pronounced abnormalities of the foot-knee complex were observed. Following treatment, gait symmetry improved in both groups as did the position of the hemiparetic foot in the mid-support phase. In the inhibitive casting groups, similar improvements were also observed in the initial contact phase. In the knee, greater improvement in knee was noted in the Btx-A group. Btx-A injections or inhibitive casts improve gait parameters in cerebral palsied children. This improvement is individual and seen in different stages of the support phase, but of similar magnitude following the use of either treatment. Achieving simultaneous improvement in the knee and foot is difficult.

  12. Predicting timing of foot strike during running, independent of striking technique, using principal component analysis of joint angles.

    PubMed

    Osis, Sean T; Hettinga, Blayne A; Leitch, Jessica; Ferber, Reed

    2014-08-22

    As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical features. Therefore, the purpose of this study was to define a new foot strike detection method for a continuum of striking techniques, by applying PCA to joint angle waveforms. In accordance with Newtonian mechanics, it was hypothesized that transient features in the sagittal-plane accelerations of the lower extremity would be linked with the impulsive application of force to the foot at foot strike. Kinematic and kinetic data from treadmill running were selected for 154 subjects, from a database of gait biomechanics. Ankle, knee and hip sagittal plane angular acceleration kinematic curves were chained together to form a row input to a PCA matrix. A linear polynomial was calculated based on PCA scores, and a 10-fold cross-validation was performed to evaluate prediction accuracy against gold-standard foot strike as determined by a 10 N rise in the vertical ground reaction force. Results show 89-94% of all predicted foot strikes were within 4 frames (20 ms) of the gold standard with the largest error being 28 ms. It is concluded that this new foot strike detection is an improvement on existing methods and can be applied regardless of whether the runner exhibits a rearfoot, midfoot, or forefoot strike pattern. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Computing the variations in the self-similar properties of the various gait intervals in Parkinson disease patients.

    PubMed

    Manjeri Keloth, Sana; Arjunan, Sridhar P; Kumar, Dinesh

    2017-07-01

    This study has investigated the stride, swing, stance and double support intervals of gait for Parkinson's disease (PD) patients with different levels of severity. Self-similar properties of the gait signal were analyzed to investigate the changes in the gait pattern of the healthy and PD patients. To understand the self-similar property, detrended fluctuation analysis was performed. The analysis shows that the PD patients have less defined gait when compared to healthy. The study also shows that among the stance and swing phase of stride interval, the self-similarity is less for swing interval when compared to the stance interval of gait and decreases with the severity of gait. Also, PD patients show decreased self-similar patterns in double support interval of gait. This suggest that there are less rhythmic gait intervals and a sense of urgency to remain in support phase of gait by the PD patients.

  14. A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait.

    PubMed

    Martínez-Solís, Fermín; Claudio-Sánchez, Abraham; Rodríguez-Lelis, José M; Vergara-Limon, Sergio; Olivares-Peregrino, Víctor; Vargas-Treviño, Marciano

    2014-03-31

    Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting number of steps to be analyzed. Traditional measuring gait systems carry out their measurement at frequencies oscillating between 60 to 100 Hz. It can be argued about the need of higher sampling rates for gait measurements. However small displacements of the knee or hip for example, cannot be seen with low frequencies required a more detailed sampling and higher frequency sampling. Bearing this in mind, in this paper is presented a 250 Hz system based on accelerometers for gait measurement, and the particularities of knee and hip angles during gait are highlighted. The system was designed with a PCI data acquisition card instrumented with an FPGA to achieve a rate sample of 250 Hz. The accelerometers were placed in thighs and legs to calculate the joint angles of hip and knee in the sagittal plane. The angles were estimated using the acceleration polygon method without integrating the acceleration and without filters. The gait of thirty healthy people of Mexican phenotype was analyzed over a flat floor free of obstacles. The results showed the gait phases and particularities associated with the walking style and people's laterality; the movement patterns were similar in the thirty persons. Based on the results, the particularities as the maximum amplitude in the angles and the shape in the movement patterns were related to the anthropometry and people phenotype. The sampling frequency was essential to record 340 samples in single gait cycle and so registering the gait cycle with its particularities. In this work were recorded an average of 8 to 10 gait cycles, and the results showed variation regarding works carried out in biomechanics laboratories; this variation was related to the method and reference frame used to obtain the joint angles and the accuracy of measurement system.

  15. Pilot study of the impact that bilateral sacroiliac joint manipulation using a drop table technique has on gait parameters in asymptomatic individuals with a leg length inequality.

    PubMed

    Ward, John; Sorrels, Ken; Coats, Jesse; Pourmoghaddam, Amir; Deleon, Carlos; Daigneault, Paige

    2014-03-01

    The purpose of this study was to pilot test our study procedures and estimate parameters for sample size calculations for a randomized controlled trial to determine if bilateral sacroiliac (SI) joint manipulation affects specific gait parameters in asymptomatic individuals with a leg length inequality (LLI). Twenty-one asymptomatic chiropractic students engaged in a baseline 90-second walking kinematic analysis using infrared Vicon® cameras. Following this, participants underwent a functional LLI test. Upon examination participants were classified as: left short leg, right short leg, or no short leg. Half of the participants in each short leg group were then randomized to receive bilateral corrective SI joint chiropractic manipulative therapy (CMT). All participants then underwent another 90-second gait analysis. Pre- versus post-intervention gait data were then analyzed within treatment groups by an individual who was blinded to participant group status. For the primary analysis, all p-values were corrected for multiple comparisons using the Bonferroni method. Within groups, no differences in measured gait parameters were statistically significant after correcting for multiple comparisons. The protocol of this study was acceptable to all subjects who were invited to participate. No participants refused randomization. Based on the data collected, we estimated that a larger main study would require 34 participants in each comparison group to detect a moderate effect size.

  16. Development and validity of methods for the estimation of temporal gait parameters from heel-attached inertial sensors in younger and older adults.

    PubMed

    Misu, Shogo; Asai, Tsuyoshi; Ono, Rei; Sawa, Ryuichi; Tsutsumimoto, Kota; Ando, Hiroshi; Doi, Takehiko

    2017-09-01

    The heel is likely a suitable location to which inertial sensors are attached for the detection of gait events. However, there are few studies to detect gait events and determine temporal gait parameters using sensors attached to the heels. We developed two methods to determine temporal gait parameters: detecting heel-contact using acceleration and detecting toe-off using angular velocity data (acceleration-angular velocity method; A-V method), and detecting both heel-contact and toe-off using angular velocity data (angular velocity-angular velocity method; V-V method). The aim of this study was to examine the concurrent validity of the A-V and V-V methods against the standard method, and to compare their accuracy. Temporal gait parameters were measured in 10 younger and 10 older adults. The intra-class correlation coefficients were excellent in both methods compared with the standard method (0.80 to 1.00). The root mean square errors of stance and swing time in the A-V method were smaller than the V-V method in older adults, although there were no significant discrepancies in the other comparisons. Our study suggests that inertial sensors attached to the heels, using the A-V method in particular, provide a valid measurement of temporal gait parameters. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Reliability of four models for clinical gait analysis.

    PubMed

    Kainz, Hans; Graham, David; Edwards, Julie; Walsh, Henry P J; Maine, Sheanna; Boyd, Roslyn N; Lloyd, David G; Modenese, Luca; Carty, Christopher P

    2017-05-01

    Three-dimensional gait analysis (3DGA) has become a common clinical tool for treatment planning in children with cerebral palsy (CP). Many clinical gait laboratories use the conventional gait analysis model (e.g. Plug-in-Gait model), which uses Direct Kinematics (DK) for joint kinematic calculations, whereas, musculoskeletal models, mainly used for research, use Inverse Kinematics (IK). Musculoskeletal IK models have the advantage of enabling additional analyses which might improve the clinical decision-making in children with CP. Before any new model can be used in a clinical setting, its reliability has to be evaluated and compared to a commonly used clinical gait model (e.g. Plug-in-Gait model) which was the purpose of this study. Two testers performed 3DGA in eleven CP and seven typically developing participants on two occasions. Intra- and inter-tester standard deviations (SD) and standard error of measurement (SEM) were used to compare the reliability of two DK models (Plug-in-Gait and a six degrees-of-freedom model solved using Vicon software) and two IK models (two modifications of 'gait2392' solved using OpenSim). All models showed good reliability (mean SEM of 3.0° over all analysed models and joint angles). Variations in joint kinetics were less in typically developed than in CP participants. The modified 'gait2392' model which included all the joint rotations commonly reported in clinical 3DGA, showed reasonable reliable joint kinematic and kinetic estimates, and allows additional musculoskeletal analysis on surgically adjustable parameters, e.g. muscle-tendon lengths, and, therefore, is a suitable model for clinical gait analysis. Copyright © 2017. Published by Elsevier B.V.

  18. Interpreting sources of variation in clinical gait analysis: A case study.

    PubMed

    King, Stephanie L; Barton, Gabor J; Ranganath, Lakshminarayan R

    2017-02-01

    To illustrate and discuss sources of gait deviations (experimental, genuine and intentional) during a gait analysis and how these deviations inform clinical decision making. A case study of a 24-year old male diagnosed with Alkaptonuria undergoing a routine gait analysis. A 3D motion capture with the Helen-Hayes marker set was used to quantify lower-limb joint kinematics during barefoot walking along a 10m walkway at a self-selected pace. Additional 2D video data were recorded in the sagittal and frontal plane. The patient reported no aches or pains in any joint and described his lifestyle as active. Temporal-spatial parameters were within normal ranges for his age and sex. Three sources of gait deviations were identified; the posteriorly rotated pelvis was due to an experimental error and marker misplacement, the increased rotation of the pelvis in the horizontal plane was genuine and observed in both 3D gait curves and in 2D video analysis, finally the inconsistency in knee flexion/extension combined with a seemingly innocuous interest in the consequences of abnormal gait suggested an intentional gait deviation. Gait analysis is an important analytical tool in the management of a variety of conditions that negatively impact on movement. Experienced gait analysts have the ability to recognise genuine gait adaptations that forms part of the decision-making process for that patient. However, their role also necessitates the ability to identify and correct for experimental errors and critically evaluate when a deviation may not be genuine. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Gait Strategy in Patients with Ehlers-Danlos Syndrome Hypermobility Type: A Kinematic and Kinetic Evaluation Using 3D Gait Analysis

    ERIC Educational Resources Information Center

    Galli, Manuela; Cimolin, Veronica; Rigoldi, Chiara; Castori, Marco; Celletti, Claudia; Albertini, Giorgio; Camerota, Filippo

    2011-01-01

    The aim of this study was to quantify the gait patterns of adults with joint hypermobility syndrome/Ehlers-Danlos syndrome (JHS/EDS-HT) hypermobility type, using Gait Analysis. We quantified the gait strategy in 12 JHS/EDS-HT adults individuals (age: 43.08 + 6.78 years) compared to 20 healthy controls (age: 37.23 plus or minus 8.91 years), in…

  20. Terminology and forensic gait analysis.

    PubMed

    Birch, Ivan; Vernon, Wesley; Walker, Jeremy; Young, Maria

    2015-07-01

    The use of appropriate terminology is a fundamental aspect of forensic gait analysis. The language used in forensic gait analysis is an amalgam of that used in clinical practice, podiatric biomechanics and the wider field of biomechanics. The result can often be a lack of consistency in the language used, the definitions used and the clarity of the message given. Examples include the use of 'gait' and 'walking' as synonymous terms, confusion between 'step' and 'stride', the mixing of anatomical, positional and pathological descriptors, and inability to describe appropriately movements of major body segments such as the torso. The purpose of this paper is to share the well-established definitions of the fundamental parameters of gait, common to all professions, and advocate their use in forensic gait analysis to establish commonality. The paper provides guidance on the selection and use of appropriate terminology in the description of gait in the forensic context. This paper considers the established definitions of the terms commonly used, identifies those terms which have the potential to confuse readers, and suggests a framework of terminology which should be utilised in forensic gait analysis. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Research the Gait Characteristics of Human Walking Based on a Robot Model and Experiment

    NASA Astrophysics Data System (ADS)

    He, H. J.; Zhang, D. N.; Yin, Z. W.; Shi, J. H.

    2017-02-01

    In order to research the gait characteristics of human walking in different walking ways, a robot model with a single degree of freedom is put up in this paper. The system control models of the robot are established through Matlab/Simulink toolbox. The gait characteristics of straight, uphill, turning, up the stairs, down the stairs up and down areanalyzed by the system control models. To verify the correctness of the theoretical analysis, an experiment was carried out. The comparison between theoretical results and experimental results shows that theoretical results are better agreement with the experimental ones. Analyze the reasons leading to amplitude error and phase error and give the improved methods. The robot model and experimental ways can provide foundation to further research the various gait characteristics of the exoskeleton robot.

  2. The effect of gait training with shoe inserts on the improvement of pain and gait in sacroiliac joint patients.

    PubMed

    Cho, Byung-Yun; Yoon, Jung-Gyu

    2015-08-01

    [Purpose] The purpose of the current research was to identify how gait training with shoe inserts affects the pain and gait of sacroiliac joint dysfunction patients. [Subjects and Methods] Thirty subjects were randomly selected and assigned to be either the experimental group (gait training with shoe insert group) or control group. Each group consisted of 15 patients. Pain was measured by Visual Analogue Scale, and foot pressure in a standing position and during gait was measured with a Gateview AFA-50 system (Alpus, Seoul, Republic of Korea). A paired sample t-test was used to compare the pain and gait of the sacroiliac joint before and after the intervention. Correlation between pain and walking after gait training with shoe inserts was examined by Pearson test. The level of significance was set at α=0.05. [Results] It was found that application of the intervention to the experimental group resulted in a significant decrease in sacroiliac joint pain. It was also found that there was a significant correlation between Visual Analogue Scale score and dynamic asymmetric index (r= 0.796) and that there was a negative correlation between Visual Analogue Scale score and forefoot/rear foot peak pressure ratio (r=-0.728). [Conclusion] The results of our analysis lead us to conclude that the intervention with shoe inserts had a significant influence on the pain and gait of sacroiliac joint patients.

  3. The effect of gait training with shoe inserts on the improvement of pain and gait in sacroiliac joint patients

    PubMed Central

    Cho, Byung-Yun; Yoon, Jung-Gyu

    2015-01-01

    [Purpose] The purpose of the current research was to identify how gait training with shoe inserts affects the pain and gait of sacroiliac joint dysfunction patients. [Subjects and Methods] Thirty subjects were randomly selected and assigned to be either the experimental group (gait training with shoe insert group) or control group. Each group consisted of 15 patients. Pain was measured by Visual Analogue Scale, and foot pressure in a standing position and during gait was measured with a Gateview AFA-50 system (Alpus, Seoul, Republic of Korea). A paired sample t-test was used to compare the pain and gait of the sacroiliac joint before and after the intervention. Correlation between pain and walking after gait training with shoe inserts was examined by Pearson test. The level of significance was set at α=0.05. [Results] It was found that application of the intervention to the experimental group resulted in a significant decrease in sacroiliac joint pain. It was also found that there was a significant correlation between Visual Analogue Scale score and dynamic asymmetric index (r= 0.796) and that there was a negative correlation between Visual Analogue Scale score and forefoot/rear foot peak pressure ratio (r=-0.728). [Conclusion] The results of our analysis lead us to conclude that the intervention with shoe inserts had a significant influence on the pain and gait of sacroiliac joint patients. PMID:26357428

  4. Effects of conventional overground gait training and a gait trainer with partial body weight support on spatiotemporal gait parameters of patients after stroke

    PubMed Central

    Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Noh, Ji-Woong; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Kim, Junghwan

    2015-01-01

    [Purpose] The purpose of this study was to confirm the effects of both conventional overground gait training (CGT) and a gait trainer with partial body weight support (GTBWS) on spatiotemporal gait parameters of patients with hemiparesis following chronic stroke. [Subjects and Methods] Thirty stroke patients were alternately assigned to one of two treatment groups, and both groups underwent CGT and GTBWS. [Results] The functional ambulation classification on the affected side improved significantly in the CGT and GTBWS groups. Walking speed also improved significantly in both groups. [Conclusion] These results suggest that the GTBWS in company with CGT may be, in part, an effective method of gait training for restoring gait ability in patients after a stroke. PMID:26157272

  5. Effects of conventional overground gait training and a gait trainer with partial body weight support on spatiotemporal gait parameters of patients after stroke.

    PubMed

    Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Noh, Ji-Woong; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Kim, Junghwan

    2015-05-01

    [Purpose] The purpose of this study was to confirm the effects of both conventional overground gait training (CGT) and a gait trainer with partial body weight support (GTBWS) on spatiotemporal gait parameters of patients with hemiparesis following chronic stroke. [Subjects and Methods] Thirty stroke patients were alternately assigned to one of two treatment groups, and both groups underwent CGT and GTBWS. [Results] The functional ambulation classification on the affected side improved significantly in the CGT and GTBWS groups. Walking speed also improved significantly in both groups. [Conclusion] These results suggest that the GTBWS in company with CGT may be, in part, an effective method of gait training for restoring gait ability in patients after a stroke.

  6. Gait parameters extraction by using mobile robot equipped with Kinect v2

    NASA Astrophysics Data System (ADS)

    Ogawa, Ami; Mita, Akira; Yorozu, Ayanori; Takahashi, Masaki

    2016-04-01

    The needs for monitoring systems to be used in houses are getting stronger because of the increase of the single household population due to the low birth rate and longevity. Among others, gait parameters are under the spotlight to be examined as the relations with several diseases have been reported. It is known that the gait parameters obtained at a walk test are different from those obtained under the daily life. Thus, the system which can measure the gait parameters in the real living environment is needed. Generally, gait abilities are evaluated by a measurement test, such as Timed Up and Go test and 6-minute walking test. However, these methods need measurers, so the accuracy depends on them and the lack of objectivity is pointed out. Although, a precise motion capture system is used for more objective measurement, it is hard to be used in daily measurement, because the subjects have to put the markers on their body. To solve this problem, marker less sensors, such as Kinect, are developed and used for gait information acquisition. When they are attached to a mobile robot, there is no limitation of distance. However, they still have challenges of calibration for gait parameters, and the important gait parameters to be acquired are not well examined. Therefore, in this study, we extract the important parameters for gait analysis, which have correlations with diseases and age differences, and suggest the gait parameters extraction from depth data by Kinect v2 which is mounted on a mobile robot aiming at applying to the living environment.

  7. Three-Dimensional Trunk and Lower Limbs Characteristics during Gait in Patients with Huntington's Disease.

    PubMed

    Mirek, Elzbieta; Filip, Magdalena; Chwała, Wiesław; Banaszkiewicz, Krzysztof; Rudzinska-Bar, Monika; Szymura, Jadwiga; Pasiut, Szymon; Szczudlik, Andrzej

    2017-01-01

    Objective: A number of studies on gait disturbances have been conducted, however, no clear pattern of gait disorders was described. The aim of the study was to characterize the gait pattern in HD patients by conducting analysis of mean angular movement changes the lower limb joints and trunk (kinematics parameters). Methods: The study group consisted of 30 patients with HD (17 women and 13 men). The reference data include the results of 30 healthy subjects (17 women and 13 men). Registration of gait with the Vicon 250 system was performed using passive markers attached to specific anthropometric points directly on the skin, based on the Golem biomechanical model (Oxford Metrics Ltd.). The research group and the control group were tested once. Results: Statistically significant ( p < 0.05) angular changes in gait cycle for HD patients were observed in: insufficient plantar flexion during Loading Response and Pre-swing phases; insufficient flexion of the knee joint during Initial Swing and Mid Swing phases; excessive flexion of the hip in Terminal Stance and Pre-swing phases and over-normative forward inclination of the trunk in all gait phases. It should be noted that the group of patients with HD obtained, for all the mean angular movement changes higher standard deviation. Conclusion: A characteristic gait disorder common to all patients with HD occurring throughout the whole duration of the gait cycle is a pathological anterior tilt of the trunk. The results will significantly contribute to programming physiotherapy for people with HD, aimed at stabilizing the trunk in a position of extension during gait.

  8. Health Monitors for Chronic Disease by Gait Analysis with Mobile Phones

    PubMed Central

    Juen, Joshua; Cheng, Qian; Prieto-Centurion, Valentin; Krishnan, Jerry A.

    2014-01-01

    Abstract We have developed GaitTrack, a phone application to detect health status while the smartphone is carried normally. GaitTrack software monitors walking patterns, using only accelerometers embedded in phones to record spatiotemporal motion, without the need for sensors external to the phone. Our software transforms smartphones into health monitors, using eight parameters of phone motion transformed into body motion by the gait model. GaitTrack is designed to detect health status while the smartphone is carried during normal activities, namely, free-living walking. The current method for assessing free-living walking is medical accelerometers, so we present evidence that mobile phones running our software are more accurate. We then show our gait model is more accurate than medical pedometers for counting steps of patients with chronic disease. Our gait model was evaluated in a pilot study involving 30 patients with chronic lung disease. The six-minute walk test (6MWT) is a major assessment for chronic heart and lung disease, including congestive heart failure and especially chronic obstructive pulmonary disease (COPD), affecting millions of persons. The 6MWT consists of walking back and forth along a measured distance for 6 minutes. The gait model using linear regression performed with 94.13% accuracy in measuring walk distance, compared with the established standard of direct observation. We also evaluated a different statistical model using the same gait parameters to predict health status through lung function. This gait model has high accuracy when applied to demographic cohorts, for example, 89.22% accuracy testing the cohort of 12 female patients with ages 50–64 years. PMID:24694291

  9. Analysis of Interrelationships among Voluntary and Prosthetic Leg Joint Parameters Using Cyclograms.

    PubMed

    Jasni, Farahiyah; Hamzaid, Nur Azah; Mohd Syah, Nor Elleeiana; Chung, Tze Y; Abu Osman, Noor Azuan

    2017-01-01

    The walking mechanism of a prosthetic leg user is a tightly coordinated movement of several joints and limb segments. The interaction among the voluntary and mechanical joints and segments requires particular biomechanical insight. This study aims to analyze the inter-relationship between amputees' voluntary and mechanical coupled leg joints variables using cyclograms. From this analysis, the critical gait parameters in each gait phase were determined and analyzed if they contribute to a better powered prosthetic knee control design. To develop the cyclogram model, 20 healthy able-bodied subjects and 25 prosthesis and orthosis users (10 transtibial amputees, 5 transfemoral amputees, and 10 different pathological profiles of orthosis users) walked at their comfortable speed in a 3D motion analysis lab setting. The gait parameters (i.e., angle, moment and power for the ankle, knee and hip joints) were coupled to form 36 cyclograms relationship. The model was validated by quantifying the gait disparities of all the pathological walking by analyzing each cyclograms pairs using feed-forward neural network with backpropagation. Subsequently, the cyclogram pairs that contributed to the highest gait disparity of each gait phase were manipulated by replacing it with normal values and re-analyzed. The manipulated cyclograms relationship that showed highest improvement in terms of gait disparity calculation suggested that they are the most dominant parameters in powered-knee control. In case of transfemoral amputee walking, it was identified using this approach that at each gait sub-phase, the knee variables most responsible for closest to normal walking were: knee power during loading response and mid-stance, knee moment and knee angle during terminal stance phase, knee angle and knee power during pre-swing, knee angle at initial swing, and knee power at terminal swing. No variable was dominant during mid-swing phase implying natural pendulum effect of the lower limb between the initial and terminal swing phases. The outcome of this cyclogram adoption approach proposed an insight into the method of determining the causal effect of manipulating a particular joint's mechanical properties toward the joint behavior in an amputee's gait by determining the curve closeness, C, of the modified cyclogram curve to the normal conventional curve, to enable quantitative judgment of the effect of changing a particular parameter in the prosthetic leg gait.

  10. A biofeedback cycling training to improve locomotion: a case series study based on gait pattern classification of 153 chronic stroke patients

    PubMed Central

    2011-01-01

    Background The restoration of walking ability is the main goal of post-stroke lower limb rehabilitation and different studies suggest that pedaling may have a positive effect on locomotion. The aim of this study was to explore the feasibility of a biofeedback pedaling treatment and its effects on cycling and walking ability in chronic stroke patients. A case series study was designed and participants were recruited based on a gait pattern classification of a population of 153 chronic stroke patients. Methods In order to optimize participants selection, a k-means cluster analysis was performed to subgroup homogenous gait patterns in terms of gait speed and symmetry. The training consisted of a 2-week treatment of 6 sessions. A visual biofeedback helped the subjects in maintaining a symmetrical contribution of the two legs during pedaling. Participants were assessed before, after training and at follow-up visits (one week after treatment). Outcome measures were the unbalance during a pedaling test, and the temporal, spatial, and symmetry parameters during gait analysis. Results and discussion Three clusters, mainly differing in terms of gait speed, were identified and participants, representative of each cluster, were selected. An intra-subject statistical analysis (ANOVA) showed that all patients significantly decreased the pedaling unbalance after treatment and maintained significant improvements with respect to baseline at follow-up. The 2-week treatment induced some modifications in the gait pattern of two patients: one, the most impaired, significantly improved mean velocity and increased gait symmetry; the other one reduced significantly the over-compensation of the healthy limb. No benefits were produced in the gait of the last subject who maintained her slow but almost symmetrical pattern. Thus, this study might suggest that the treatment can be beneficial for patients having a very asymmetrical and inefficient gait and for those that overuse the healthy leg. Conclusion The results demonstrated that the treatment is feasible and it might be effective in translating progresses from pedaling to locomotion. If these results are confirmed on a larger and controlled scale, the intervention, thanks to its safety and low price, could have a significant impact as a home- rehabilitation treatment for chronic stroke patients. PMID:21861930

  11. Development of a hip joint model for finite volume simulations.

    PubMed

    Cardiff, P; Karač, A; FitzPatrick, D; Ivanković, A

    2014-01-01

    This paper establishes a procedure for numerical analysis of a hip joint using the finite volume method. Patient-specific hip joint geometry is segmented directly from computed tomography and magnetic resonance imaging datasets and the resulting bone surfaces are processed into a form suitable for volume meshing. A high resolution continuum tetrahedral mesh has been generated, where a sandwich model approach is adopted; the bones are represented as a stiffer cortical shells surrounding more flexible cancellous cores. Cartilage is included as a uniform thickness extruded layer and the effect of layer thickness is investigated. To realistically position the bones, gait analysis has been performed giving the 3D positions of the bones for the full gait cycle. Three phases of the gait cycle are examined using a finite volume based custom structural contact solver implemented in open-source software OpenFOAM.

  12. Femoral anteversion assessment: Comparison of physical examination, gait analysis, and EOS biplanar radiography.

    PubMed

    Westberry, David E; Wack, Linda I; Davis, Roy B; Hardin, James W

    2018-05-01

    Multiple measurement methods are available to assess transverse plane alignment of the lower extremity. This study was performed to determine the extent of correlation between femoral anteversion assessment using simultaneous biplanar radiographs and three-dimensional modeling (EOS imaging), clinical hip rotation by physical examination, and dynamic hip rotation assessed by gait analysis. Seventy-seven patients with cerebral palsy (GMFCS Level I and II) and 33 neurologically typical children with torsional abnormalities completed a comprehensive gait analysis with same day biplanar anterior-posterior and lateral radiographs and three-dimensional transverse plane assessment of femoral anteversion. Correlations were determined between physical exam of hip rotation, EOS imaging of femoral anteversion, and transverse plane hip kinematics for this retrospective review study. Linear regression analysis revealed a weak relationship between physical examination measures of hip rotation and biplanar radiographic assessment of femoral anteversion. Similarly, poor correlation was found between clinical evaluation of femoral anteversion and motion assessment of dynamic hip rotation. Correlations were better in neurologically typical children with torsional abnormalities compared to children with gait dysfunction secondary to cerebral palsy. Dynamic hip rotation cannot be predicted by physical examination measures of hip range of motion or from three-dimensional assessment of femoral anteversion derived from biplanar radiographs. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Laboratory review: the role of gait analysis in seniors' mobility and fall prevention.

    PubMed

    Bridenbaugh, Stephanie A; Kressig, Reto W

    2011-01-01

    Walking is a complex motor task generally performed automatically by healthy adults. Yet, by the elderly, walking is often no longer performed automatically. Older adults require more attention for motor control while walking than younger adults. Falls, often with serious consequences, can be the result. Gait impairments are one of the biggest risk factors for falls. Several studies have identified changes in certain gait parameters as independent predictors of fall risk. Such gait changes are often too discrete to be detected by clinical observation alone. At the Basel Mobility Center, we employ the GAITRite electronic walkway system for spatial-temporal gait analysis. Although we have a large range of indications for gait analyses and several areas of clinical research, our focus is on the association between gait and cognition. Gait analysis with walking as a single-task condition alone is often insufficient to reveal underlying gait disorders present during normal, everyday activities. We use a dual-task paradigm, walking while simultaneously performing a second cognitive task, to assess the effects of divided attention on motor performance and gait control. Objective quantification of such clinically relevant gait changes is necessary to determine fall risk. Early detection of gait disorders and fall risk permits early intervention and, in the best-case scenario, fall prevention. We and others have shown that rhythmic movement training such as Jaques-Dalcroze eurhythmics, tai chi and social dancing can improve gait regularity and automaticity, thus increasing gait safety and reducing fall risk. Copyright © 2010 S. Karger AG, Basel.

  14. Toward a low-cost gait analysis system for clinical and free-living assessment.

    PubMed

    Ladha, Cassim; Del Din, Silvia; Nazarpour, Kianoush; Hickey, Aodhan; Morris, Rosie; Catt, Michael; Rochester, Lynn; Godfrey, Alan

    2016-08-01

    Gait is an important clinical assessment tool since changes in gait may reflect changes in general health. Measurement of gait is a complex process which has been restricted to bespoke clinical facilities until recently. The use of inexpensive wearable technologies is an attractive alternative and offers the potential to assess gait in any environment. In this paper we present the development of a low cost analysis gait system built using entirely open source components. The system is used to capture spatio-temporal gait characteristics derived from an existing conceptual model, sensitive to ageing and neurodegenerative pathology (e.g. Parkinson's disease). We demonstrate the system is suitable for use in a clinical unit and will lead to pragmatic use in a free-living (home) environment. The system consists of a wearable (tri-axial accelerometer and gyroscope) with a Raspberry Pi module for data storage and analysis. This forms ongoing work to develop gait as a low cost diagnostic in modern healthcare.

  15. Statically vs dynamically balanced gait: Analysis of a robotic exoskeleton compared with a human.

    PubMed

    Barbareschi, Giulia; Richards, Rosie; Thornton, Matt; Carlson, Tom; Holloway, Catherine

    2015-01-01

    In recent years exoskeletons able to replicate human gait have begun to attract growing popularity for both assistive and rehabilitative purposes. Although wearable robots often need the use of external support in order to maintain stability, the REX exoskeleton by REX Bionics is able to self-balance through the whole cycle. However this statically balanced gait presents important differences with the dynamically balanced gait of human subjects. This paper will examine kinematic and kinetic differences between the gait analysis performed on a subject wearing the REX exoskeleton and human gait analysis data as presented in literature. We will also provide an insight on the impact that these differences can have for both rehabilitative and assistive applications.

  16. Evaluation of the relationship between the static measurement of transverse arch flexibility of the forefoot and gait parameters in healthy subjects.

    PubMed

    Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu

    2017-03-01

    [Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study's findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait.

  17. Evaluation of the relationship between the static measurement of transverse arch flexibility of the forefoot and gait parameters in healthy subjects

    PubMed Central

    Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu

    2017-01-01

    [Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study’s findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait. PMID:28356622

  18. Change in gait after high tibial osteotomy: A systematic review and meta-analysis.

    PubMed

    Lee, Seung Hoon; Lee, O-Sung; Teo, Seow Hui; Lee, Yong Seuk

    2017-09-01

    We conducted a meta-analysis to analyze how high tibial osteotomy (HTO) changes gait and focused on the following questions: (1) How does HTO change basic gait variables? (2) How does HTO change the gait variables in the knee joint? Twelve articles were included in the final analysis. A total of 383 knees was evaluated. There were 237 open wedge (OW) and 143 closed wedge (CW) HTOs. There were 4 level II studies and 8 level III studies. All studies included gait analysis and compared pre- and postoperative values. One study compared CWHTO and unicompartmental knee arthroplasty (UKA), and another study compared CWHTO and OWHTO. Five studies compared gait variables with those of healthy controls. One study compared operated limb gait variables with those in the non-operated limb. Gait speed, stride length, knee adduction moment, and lateral thrust were major variables assessed in 2 or more studies. Walking speed increased and stride length was increased or similar after HTO compared to the preoperative value in basic gait variables. Knee adduction moment and lateral thrust were decreased after HTO compared to the preoperative knee joint gait variables. Change in co-contraction of the medial side muscle after surgery differed depending on the degree of frontal plane alignment. The relationship between change in knee adduction moment and change in mechanical axis angle was controversial. Based on our systematic review and meta-analysis, walking speed and stride length increased after HTO. Knee adduction moment and lateral thrust decreased after HTO compared to the preoperative values of gait variables in the knee joint. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Model Predictive Control-based gait pattern generation for wearable exoskeletons.

    PubMed

    Wang, Letian; van Asseldonk, Edwin H F; van der Kooij, Herman

    2011-01-01

    This paper introduces a new method for controlling wearable exoskeletons that do not need predefined joint trajectories. Instead, it only needs basic gait descriptors such as step length, swing duration, and walking speed. End point Model Predictive Control (MPC) is used to generate the online joint trajectories based on these gait parameters. Real-time ability and control performance of the method during the swing phase of gait cycle is studied in this paper. Experiments are performed by helping a human subject swing his leg with different patterns in the LOPES gait trainer. Results show that the method is able to assist subjects to make steps with different step length and step duration without predefined joint trajectories and is fast enough for real-time implementation. Future study of the method will focus on controlling the exoskeletons in the entire gait cycle. © 2011 IEEE

  20. Proposition of a Classification of Adult Patients with Hemiparesis in Chronic Phase

    PubMed Central

    Filipetti, Paul; Remacle, Angélique; Kolanowski, Elisabeth

    2016-01-01

    Background Patients who have developed hemiparesis as a result of a central nervous system lesion, often experience reduced walking capacity and worse gait quality. Although clinically, similar gait patterns have been observed, presently, no clinically driven classification has been validated to group these patients’ gait abnormalities at the level of the hip, knee and ankle joints. This study has thus intended to put forward a new gait classification for adult patients with hemiparesis in chronic phase, and to validate its discriminatory capacity. Methods and Findings Twenty-six patients with hemiparesis were included in this observational study. Following a clinical examination, a clinical gait analysis, complemented by a video analysis, was performed whereby participants were requested to walk spontaneously on a 10m walkway. A patient’s classification was established from clinical examination data and video analysis. This classification was made up of three groups, including two sub-groups, defined with key abnormalities observed whilst walking. Statistical analysis was achieved on the basis of 25 parameters resulting from the clinical gait analysis in order to assess the discriminatory characteristic of the classification as displayed by the walking speed and kinematic parameters. Results revealed that the parameters related to the discriminant criteria of the proposed classification were all significantly different between groups and subgroups. More generally, nearly two thirds of the 25 parameters showed significant differences (p<0.05) between the groups and sub-groups. However, prior to being fully validated, this classification must still be tested on a larger number of patients, and the repeatability of inter-operator measures must be assessed. Conclusions This classification enables patients to be grouped on the basis of key abnormalities observed whilst walking and has the advantage of being able to be used in clinical routines without necessitating complex apparatus. In the midterm, this classification may allow a decision-tree of therapies to be developed on the basis of the group in which the patient has been categorised. PMID:27271533

  1. Optics in gait analysis and anthropometry

    NASA Astrophysics Data System (ADS)

    Silva Moreno, Alejandra Alicia

    2013-11-01

    Since antiquity, human gait has been studied to understand human movement, the kind of gait, in some cases, can cause musculoskeletal disorders or other health problems; in addition, also from antiquity, anthropometry has been important for the design of human items such as workspaces, tools, garments, among others. Nowadays, thanks to the development of optics and electronics, more accurate studies of gait and anthropometry can be developed. This work will describe the most important parameters for gait analysis, anthropometry and the optical systems used.

  2. Challenging Gait Conditions Predict 1-Year Decline in Gait Speed in Older Adults With Apparently Normal Gait

    PubMed Central

    Perera, Subashan; VanSwearingen, Jessie M.; Hile, Elizabeth S.; Wert, David M.; Studenski, Stephanie A.

    2011-01-01

    Background Mobility often is tested under a low challenge condition (ie, over a straight, uncluttered path), which often fails to identify early mobility difficulty. Tests of walking during challenging conditions may uncover mobility difficulty that is not identified with usual gait testing. Objective The purpose of this study was to determine whether gait during challenging conditions predicts decline in gait speed over 1 year in older people with apparently normal gait (ie, gait speed of ≥1.0 m/s). Design This was a prospective cohort study. Methods Seventy-one older adults (mean age=75.9 years) with a usual gait speed of ≥1.0 m/s participated. Gait was tested at baseline under 4 challenging conditions: (1) narrow walk (15 cm wide), (2) stepping over obstacles (15.24 cm [6 in] and 30.48 cm [12 in]), (3) simple walking while talking (WWT), and (4) complex WWT. Usual gait speed was recorded over a 4-m course at baseline and 1 year later. A 1-year change in gait speed was calculated, and participants were classified as declined (decreased ≥0.10 m/s, n=18), stable (changed <0.10 m/s, n=43), or improved (increased ≥0.10 m/s, n=10). Analysis of variance was used to compare challenging condition cost (usual − challenging condition gait speed difference) among the 3 groups. Results Participants who declined in the ensuing year had a greater narrow walk and obstacle walk cost than those who were stable or who improved in gait speed (narrow walk cost=0.43 versus 0.33 versus 0.22 m/s and obstacle walk cost=0.35 versus 0.26 versus 0.13 m/s). Simple and complex WWT cost did not differ among the groups. Limitations The participants who declined in gait speed over time walked the fastest, and those who improved walked the slowest at baseline; thus, the potential contribution of regression to the mean to the findings should not be overlooked. Conclusions In older adults with apparently normal gait, the assessment of gait during challenging conditions appears to uncover mobility difficulty that is not identified by usual gait testing. PMID:22003167

  3. The effects of aquatic trunk exercise on gait and muscle activity in stroke patients: a randomized controlled pilot study.

    PubMed

    Park, Byoung-Sun; Noh, Ji-Woong; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-11-01

    [Purpose] The purpose of this study was to investigate the relationship between muscle activity and gait function following aquatic trunk exercise in hemiplegic stroke patients. [Subjects and Methods] This study's participants included thirteen hemiplegic patients (ten males and three females). The aquatic therapy consisted of administering concentrative aquatic therapy for four weeks in a therapeutic pool. Gait parameters were measured using a gait analysis system adjusted to each subject's comfortable walking speed. Electromyographic signals were measured for the rectus abdominis, external abdominal oblique, transversus abdominis/internal-abdominal oblique, and erector spine of each patients. [Results] The pre- and post-training performances of the transversus abdominis/internal-abdominal oblique were compared statistically. There was no statistical difference between the patients' pre- and post-training values of maximal voluntary isometric contraction of the rectus abdominis, but the external abdominal oblique values tended to improve. Furthermore, gait factors improved significantly in terms of walking speeds, walking cycles, affected-side stance phases, affected-stride lengths, and stance-phase symmetry indices, respectively. [Conclusion] These results suggest that the trunk exercise during aquatic therapy may in part contribute to clinically relevant improvements in muscle activities and gait parameters.

  4. The effects of aquatic trunk exercise on gait and muscle activity in stroke patients: a randomized controlled pilot study

    PubMed Central

    Park, Byoung-Sun; Noh, Ji-Woong; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-01-01

    [Purpose] The purpose of this study was to investigate the relationship between muscle activity and gait function following aquatic trunk exercise in hemiplegic stroke patients. [Subjects and Methods] This study’s participants included thirteen hemiplegic patients (ten males and three females). The aquatic therapy consisted of administering concentrative aquatic therapy for four weeks in a therapeutic pool. Gait parameters were measured using a gait analysis system adjusted to each subject’s comfortable walking speed. Electromyographic signals were measured for the rectus abdominis, external abdominal oblique, transversus abdominis/internal-abdominal oblique, and erector spine of each patients. [Results] The pre- and post-training performances of the transversus abdominis/internal-abdominal oblique were compared statistically. There was no statistical difference between the patients’ pre- and post-training values of maximal voluntary isometric contraction of the rectus abdominis, but the external abdominal oblique values tended to improve. Furthermore, gait factors improved significantly in terms of walking speeds, walking cycles, affected-side stance phases, affected-stride lengths, and stance-phase symmetry indices, respectively. [Conclusion] These results suggest that the trunk exercise during aquatic therapy may in part contribute to clinically relevant improvements in muscle activities and gait parameters. PMID:26696736

  5. Does Nordic walking improves the postural control and gait parameters of women between the age 65 and 74: a randomized trial

    PubMed Central

    Kocur, Piotr; Wiernicka, Marzena; Wilski, Maciej; Kaminska, Ewa; Furmaniuk, Lech; Maslowska, Marta Flis; Lewandowski, Jacek

    2015-01-01

    [Purpose] To assess the effect of 12-weeks Nordic walking training on gait parameters and some elements of postural control. [Subjects and Methods] Sixty-seven women aged 65 to 74 years were enrolled in this study. The subjects were divided into a Nordic Walking group (12 weeks of Nordic walking training, 3 times a week for 75 minutes) and a control group. In both study groups, a set of functional tests were conducted at the beginning and at the end of the study: the Forward Reach Test (FRT) and the Upward Reach Test (URT) on a stabilometric platform, and the analysis of gait parameters on a treadmill. [Results] The NW group showed improvements in: the range of reach in the FRT test and the URT test in compared to the control group. The length of the gait cycle and gait cycle frequency also showed changes in the NW group compared to the control group. [Conclusion] A 12-week NW training program had a positive impact on selected gait parameters and may improve the postural control of women aged over 65 according to the results selected functional tests. PMID:26834341

  6. Does Nordic walking improves the postural control and gait parameters of women between the age 65 and 74: a randomized trial.

    PubMed

    Kocur, Piotr; Wiernicka, Marzena; Wilski, Maciej; Kaminska, Ewa; Furmaniuk, Lech; Maslowska, Marta Flis; Lewandowski, Jacek

    2015-12-01

    [Purpose] To assess the effect of 12-weeks Nordic walking training on gait parameters and some elements of postural control. [Subjects and Methods] Sixty-seven women aged 65 to 74 years were enrolled in this study. The subjects were divided into a Nordic Walking group (12 weeks of Nordic walking training, 3 times a week for 75 minutes) and a control group. In both study groups, a set of functional tests were conducted at the beginning and at the end of the study: the Forward Reach Test (FRT) and the Upward Reach Test (URT) on a stabilometric platform, and the analysis of gait parameters on a treadmill. [Results] The NW group showed improvements in: the range of reach in the FRT test and the URT test in compared to the control group. The length of the gait cycle and gait cycle frequency also showed changes in the NW group compared to the control group. [Conclusion] A 12-week NW training program had a positive impact on selected gait parameters and may improve the postural control of women aged over 65 according to the results selected functional tests.

  7. Assessment of stability during gait in patients with spinal deformity-A preliminary analysis using the dynamic stability margin.

    PubMed

    Simon, Anne-Laure; Lugade, Vipul; Bernhardt, Kathie; Larson, A Noelle; Kaufman, Kenton

    2017-06-01

    Daily living activities are dynamic, requiring spinal motion through space. Current assessment of spinal deformities is based on static measurements from full-spine standing radiographs. Tools to assess dynamic stability during gait might be useful to enhance the standard evaluation. The aim of this study was to evaluate gait dynamic imbalance in patients with spinal deformity using the dynamic stability margin (DSM). Twelve normal subjects and 17 patients with spinal deformity were prospectively recruited. A kinematic 3D gait analysis was performed for the control group (CG) and the spinal deformity group (SDG). The DSM (distance between the extrapolated center of mass and the base of support) and time-distance parameters were calculated for the right and left side during gait. The relationship between DSM and step length was assessed using three variables: gait stability, symmetry, and consistency. Variables' accuracy was validated by a discriminant analysis. Patients with spinal deformity exhibited gait instability according to the DSM (0.25m versus 0.31m) with decreased velocity (1.1ms -1 versus 1.3ms -1 ) and decreased step length (0.32m versus 0.38m). According to the discriminant analysis, gait stability was the more accurate variable (area under the curve AUC=0.98) followed by gait symmetry and consistency. However, gait consistency showed 100% of specificity, sensitivity, and accuracy of precision. The DSM showed that patients with spinal malalignment exhibit decreased gait stability, symmetry, and consistency besides gait time-distance parameter changes. Additional work is required to determine how to apply the DSM for preoperative and postoperative spinal deformity management. Copyright © 2017. Published by Elsevier B.V.

  8. Kinematic measures for assessing gait stability in elderly individuals: a systematic review

    PubMed Central

    Hamacher, D.; Singh, N.B.; Van Dieën, J.H.; Heller, M.O.; Taylor, W.R.

    2011-01-01

    Falls not only present a considerable health threat, but the resulting treatment and loss of working days also place a heavy economic burden on society. Gait instability is a major fall risk factor, particularly in geriatric patients, and walking is one of the most frequent dynamic activities of daily living. To allow preventive strategies to become effective, it is therefore imperative to identify individuals with an unstable gait. Assessment of dynamic stability and gait variability via biomechanical measures of foot kinematics provides a viable option for quantitative evaluation of gait stability, but the ability of these methods to predict falls has generally not been assessed. Although various methods for assessing gait stability exist, their sensitivity and applicability in a clinical setting, as well as their cost-effectiveness, need verification. The objective of this systematic review was therefore to evaluate the sensitivity of biomechanical measures that quantify gait stability among elderly individuals and to evaluate the cost of measurement instrumentation required for application in a clinical setting. To assess gait stability, a comparative effect size (Cohen's d) analysis of variability and dynamic stability of foot trajectories during level walking was performed on 29 of an initial yield of 9889 articles from four electronic databases. The results of this survey demonstrate that linear variability of temporal measures of swing and stance was most capable of distinguishing between fallers and non-fallers, whereas step width and stride velocity prove more capable of discriminating between old versus young (OY) adults. In addition, while orbital stability measures (Floquet multipliers) applied to gait have been shown to distinguish between both elderly fallers and non-fallers as well as between young and old adults, local stability measures (λs) have been able to distinguish between young and old adults. Both linear and nonlinear measures of foot time series during gait seem to hold predictive ability in distinguishing healthy from fall-prone elderly adults. In conclusion, biomechanical measurements offer promise for identifying individuals at risk of falling and can be obtained with relatively low-cost tools. Incorporation of the most promising measures in combined retrospective and prospective studies for understanding fall risk and designing preventive strategies is warranted. PMID:21880615

  9. Kinematic measures for assessing gait stability in elderly individuals: a systematic review.

    PubMed

    Hamacher, D; Singh, N B; Van Dieën, J H; Heller, M O; Taylor, W R

    2011-12-07

    Falls not only present a considerable health threat, but the resulting treatment and loss of working days also place a heavy economic burden on society. Gait instability is a major fall risk factor, particularly in geriatric patients, and walking is one of the most frequent dynamic activities of daily living. To allow preventive strategies to become effective, it is therefore imperative to identify individuals with an unstable gait. Assessment of dynamic stability and gait variability via biomechanical measures of foot kinematics provides a viable option for quantitative evaluation of gait stability, but the ability of these methods to predict falls has generally not been assessed. Although various methods for assessing gait stability exist, their sensitivity and applicability in a clinical setting, as well as their cost-effectiveness, need verification. The objective of this systematic review was therefore to evaluate the sensitivity of biomechanical measures that quantify gait stability among elderly individuals and to evaluate the cost of measurement instrumentation required for application in a clinical setting. To assess gait stability, a comparative effect size (Cohen's d) analysis of variability and dynamic stability of foot trajectories during level walking was performed on 29 of an initial yield of 9889 articles from four electronic databases. The results of this survey demonstrate that linear variability of temporal measures of swing and stance was most capable of distinguishing between fallers and non-fallers, whereas step width and stride velocity prove more capable of discriminating between old versus young (OY) adults. In addition, while orbital stability measures (Floquet multipliers) applied to gait have been shown to distinguish between both elderly fallers and non-fallers as well as between young and old adults, local stability measures (λs) have been able to distinguish between young and old adults. Both linear and nonlinear measures of foot time series during gait seem to hold predictive ability in distinguishing healthy from fall-prone elderly adults. In conclusion, biomechanical measurements offer promise for identifying individuals at risk of falling and can be obtained with relatively low-cost tools. Incorporation of the most promising measures in combined retrospective and prospective studies for understanding fall risk and designing preventive strategies is warranted.

  10. Pilot study of atomoxetine in patients with Parkinson's disease and dopa-unresponsive Freezing of Gait.

    PubMed

    Revuelta, Gonzalo J; Embry, Aaron; Elm, Jordan J; Gregory, Chris; Delambo, Amy; Kautz, Steve; Hinson, Vanessa K

    2015-01-01

    Freezing of gait (FoG) is a common and debilitating condition in Parkinson's disease (PD) associated with executive dysfunction. A subtype of FoG does not respond to dopaminergic therapy and may be related to noradrenergic deficiency. This pilot study explores the effects of atomoxetine on gait in PD patients with dopa-unresponsive FoG using a novel paradigm for objective gait assessment. Ten patients with PD and dopa-unresponsive FoG were enrolled in this eight-week open label pilot study. Assessments included an exploratory gait analysis protocol that quantified spatiotemporal parameters during straight-away walking and turning, while performing a dual task. Clinical, and subjective assessments of gait, quality of life, and safety were also administered. The primary outcome was a validated subjective assessment for FoG (FOG-Q). Atomoxetine was well tolerated, however, no significant change was observed in the primary outcome. The gait analysis protocol correlated well with clinical scales, but not with subjective assessments. DBS patients were more likely to increase gait velocity (p = 0.033), and improved in other clinical assessments. Objective gait analysis protocols assessing gait while dual tasking are feasible and useful for this patient population, and may be superior correlates of FoG severity than subjective measures. These findings can inform future trials in this population.

  11. Gait impairment in neurological disorders: a new technological approach.

    PubMed

    Semprini, Roberta; Sale, Patrizio; Foti, Calogero; Fini, Massimo; Franceschini, Marco

    2009-01-01

    Gait recovery is considered one of the main objectives of rehabilitation interventions in neurological disabilities, as restricted movement can significantly reduce an individual's ability to take part in normal activities of daily living. Locomotor training has been shown to improve gait rehabilitation. Studies have recently been published on the use of robots and other devices in patients with gait disabilities, particularly in the rehabilitation of the lower limbs. However, analysis of the recent literature reveals a relative paucity of strong methodological studies. The evidence that is available, while strong, is not yet sufficient to allow definite conclusions to be drawn regarding the efficacy of these devices. From these considerations, it is clear that validated and standardized methods need to be adopted for each of the different systems available. This would help to clarify the indications for and correct use of robotic devices in the different neurological disorders.

  12. Quantitative method for gait pattern detection based on fiber Bragg grating sensors

    NASA Astrophysics Data System (ADS)

    Ding, Lei; Tong, Xinglin; Yu, Lie

    2017-03-01

    This paper presents a method that uses fiber Bragg grating (FBG) sensors to distinguish the temporal gait patterns in gait cycles. Unlike most conventional methods that focus on electronic sensors to collect those physical quantities (i.e., strains, forces, pressure, displacements, velocity, and accelerations), the proposed method utilizes the backreflected peak wavelength from FBG sensors to describe the motion characteristics in human walking. Specifically, the FBG sensors are sensitive to external strain with the result that their backreflected peak wavelength will be shifted according to the extent of the influence of external strain. Therefore, when subjects walk in different gait patterns, the strains on FBG sensors will be different such that the magnitude of the backreflected peak wavelength varies. To test the reliability of the FBG sensor platform for gait pattern detection, the gold standard method using force-sensitive resistors (FSRs) for defining gait patterns is introduced as a reference platform. The reliability of the FBG sensor platform is determined by comparing the detection results between the FBG sensors and FSRs platforms. The experimental results show that the FBG sensor platform is reliable in gait pattern detection and gains high reliability when compared with the reference platform.

  13. The complex genetics of gait speed: genome-wide meta-analysis approach

    PubMed Central

    Lunetta, Kathryn L.; Smith, Jennifer A.; Eicher, John D.; Vered, Rotem; Deelen, Joris; Arnold, Alice M.; Buchman, Aron S.; Tanaka, Toshiko; Faul, Jessica D.; Nethander, Maria; Fornage, Myriam; Adams, Hieab H.; Matteini, Amy M.; Callisaya, Michele L.; Smith, Albert V.; Yu, Lei; De Jager, Philip L.; Evans, Denis A.; Gudnason, Vilmundur; Hofman, Albert; Pattie, Alison; Corley, Janie; Launer, Lenore J.; Knopman, Davis S.; Parimi, Neeta; Turner, Stephen T.; Bandinelli, Stefania; Beekman, Marian; Gutman, Danielle; Sharvit, Lital; Mooijaart, Simon P.; Liewald, David C.; Houwing-Duistermaat, Jeanine J.; Ohlsson, Claes; Moed, Matthijs; Verlinden, Vincent J.; Mellström, Dan; van der Geest, Jos N.; Karlsson, Magnus; Hernandez, Dena; McWhirter, Rebekah; Liu, Yongmei; Thomson, Russell; Tranah, Gregory J.; Uitterlinden, Andre G.; Weir, David R.; Zhao, Wei; Starr, John M.; Johnson, Andrew D.; Ikram, M. Arfan; Bennett, David A.; Cummings, Steven R.; Deary, Ian J.; Harris, Tamara B.; Kardia, Sharon L. R.; Mosley, Thomas H.; Srikanth, Velandai K.; Windham, Beverly G.; Newman, Ann B.; Walston, Jeremy D.; Davies, Gail; Evans, Daniel S.; Slagboom, Eline P.; Ferrucci, Luigi; Kiel, Douglas P.; Murabito, Joanne M.; Atzmon, Gil

    2017-01-01

    Emerging evidence suggests that the basis for variation in late-life mobility is attributable, in part, to genetic factors, which may become increasingly important with age. Our objective was to systematically assess the contribution of genetic variation to gait speed in older individuals. We conducted a meta-analysis of gait speed GWASs in 31,478 older adults from 17 cohorts of the CHARGE consortium, and validated our results in 2,588 older adults from 4 independent studies. We followed our initial discoveries with network and eQTL analysis of candidate signals in tissues. The meta-analysis resulted in a list of 536 suggestive genome wide significant SNPs in or near 69 genes. Further interrogation with Pathway Analysis placed gait speed as a polygenic complex trait in five major networks. Subsequent eQTL analysis revealed several SNPs significantly associated with the expression of PRSS16, WDSUB1 and PTPRT, which in addition to the meta-analysis and pathway suggested that genetic effects on gait speed may occur through synaptic function and neuronal development pathways. No genome-wide significant signals for gait speed were identified from this moderately large sample of older adults, suggesting that more refined physical function phenotypes will be needed to identify the genetic basis of gait speed in aging. PMID:28077804

  14. Longitudinal quasi-static stability predicts changes in dog gait on rough terrain

    PubMed Central

    Reeve, Michelle A.; Haynes, G. Clark; Revzen, Shai; Koditschek, Daniel E.; Spence, Andrew J.

    2017-01-01

    ABSTRACT Legged animals utilize gait selection to move effectively and must recover from environmental perturbations. We show that on rough terrain, domestic dogs, Canis lupus familiaris, spend more time in longitudinal quasi-statically stable patterns of movement. Here, longitudinal refers to the rostro-caudal axis. We used an existing model in the literature to quantify the longitudinal quasi-static stability of gaits neighbouring the walk, and found that trot-like gaits are more stable. We thus hypothesized that when perturbed, the rate of return to a stable gait would depend on the direction of perturbation, such that perturbations towards less quasi-statically stable patterns of movement would be more rapid than those towards more stable patterns of movement. The net result of this would be greater time spent in longitudinally quasi-statically stable patterns of movement. Limb movement patterns in which diagonal limbs were more synchronized (those more like a trot) have higher longitudinal quasi-static stability. We therefore predicted that as dogs explored possible limb configurations on rough terrain at walking speeds, the walk would shift towards trot. We gathered experimental data quantifying dog gait when perturbed by rough terrain and confirmed this prediction using GPS and inertial sensors (n=6, P<0.05). By formulating gaits as trajectories on the n-torus we are able to make tractable the analysis of gait similarity. These methods can be applied in a comparative study of gait control which will inform the ultimate role of the constraints and costs impacting locomotion, and have applications in diagnostic procedures for gait abnormalities, and in the development of agile legged robots. PMID:28264903

  15. Longitudinal quasi-static stability predicts changes in dog gait on rough terrain.

    PubMed

    Wilshin, Simon; Reeve, Michelle A; Haynes, G Clark; Revzen, Shai; Koditschek, Daniel E; Spence, Andrew J

    2017-05-15

    Legged animals utilize gait selection to move effectively and must recover from environmental perturbations. We show that on rough terrain, domestic dogs, Canis lupus familiaris , spend more time in longitudinal quasi-statically stable patterns of movement. Here, longitudinal refers to the rostro-caudal axis. We used an existing model in the literature to quantify the longitudinal quasi-static stability of gaits neighbouring the walk, and found that trot-like gaits are more stable. We thus hypothesized that when perturbed, the rate of return to a stable gait would depend on the direction of perturbation, such that perturbations towards less quasi-statically stable patterns of movement would be more rapid than those towards more stable patterns of movement. The net result of this would be greater time spent in longitudinally quasi-statically stable patterns of movement. Limb movement patterns in which diagonal limbs were more synchronized (those more like a trot) have higher longitudinal quasi-static stability. We therefore predicted that as dogs explored possible limb configurations on rough terrain at walking speeds, the walk would shift towards trot. We gathered experimental data quantifying dog gait when perturbed by rough terrain and confirmed this prediction using GPS and inertial sensors ( n =6, P <0.05). By formulating gaits as trajectories on the n -torus we are able to make tractable the analysis of gait similarity. These methods can be applied in a comparative study of gait control which will inform the ultimate role of the constraints and costs impacting locomotion, and have applications in diagnostic procedures for gait abnormalities, and in the development of agile legged robots. © 2017. Published by The Company of Biologists Ltd.

  16. Effects of Two Years of Exercise on Gait Impairment in People with Parkinson’s Disease: The PRET-PD Randomized Trial

    PubMed Central

    Rafferty, Miriam R.; Prodoehl, Janey; Robichaud, Julie A.; David, Fabian J.; Poon, Cynthia; Goelz, Lisa C.; Vaillancourt, David E.; Kohrt, Wendy M.; Comella, Cynthia L.; Corcos, Daniel M.

    2016-01-01

    Background and Purpose This study presents a secondary analysis from the Progressive Resistance Exercise Training in Parkinson disease (PRET-PD) trial investigating the effects of progressive resistance exercise (PRE) and a PD-specific multimodal exercise program, modified Fitness Counts (mFC), on spatial, temporal, and stability-related gait impairments in people with Parkinson disease (PD). Methods Forty-eight people with PD were randomized to participate in PRE or mFC 2×/week for 24 months; 38 completed the study. Gait velocity, stride length, cadence, and double support time were measured under 4 walking conditions (off/on medication, comfortable/fast speed). Ankle strength was also measured off and on medication. Twenty-four healthy controls provided comparison data at one time point. Results At 24 months, there were no significant differences between exercise groups. Both groups improved fast gait velocity off medication, cadence in all conditions, and plantarflexion strength off/on medication. Both groups with PD had more gait measures that approximated the heathy controls at 24 months than at baseline. Plantarflexion strength was significantly associated with gait velocity and stride length in people with PD at baseline and 24 months, but changes in strength were not associated with changes in gait. Discussion and Conclusions Twenty-four months of PRE and mFC were associated with improved off medication fast gait velocity and improved cadence in all conditions, which is important because temporal gait measures can be resistant to medications. Spatial and stability-related measures were resistant to long-term improvements, but did not decline over 24 months. Strength gains did not appear to transfer to gait. Video Abstract available for more insights from the authors (see Supplemental Digital Content 1). PMID:27977518

  17. Evaluation of joint findings with gait analysis in children with hemophilia.

    PubMed

    Cayir, Atilla; Yavuzer, Gunes; Sayli, Revide Tülin; Gurcay, Eda; Culha, Vildan; Bozkurt, Murat

    2014-01-01

    Hemophilic arthropathy due to recurrent joint bleeding leads to physical, psychological and socioeconomic problems in children with hemophilia and reduces their quality of life. The purpose of this study was to evaluate joint damage through various parameters and to determine functional deterioration in the musculoskeletal system during walking using kinetic and kinematic gait analysis. Physical examination and kinetic and kinematic gait analysis findings of 19 hemophilic patients aged 7-20 years were compared with those of age, sex and leg length matched controls. Stride time was longer in the hemophilia group (p=0.001) compared to the age matched healthy control group, while hip, knee and ankle joint rotation angles were more limited (p=0.001, p=0.035 and p=0.001, respectively). In the hemophilia group, the extensor moment of the knee joint in the stance phase was less than that in the control group (p=0.001). Stride time was longer in the severe hemophilia group compared to the mild-moderate hemophilia and control groups (p=0.011 and p=0.001, respectively). Rotation angle of the ankle was wider in the control group compared to the other two groups (p=0.001 for both). Rotation angle of the ankle joint was narrower in the severe hemophilia group compared to the others (p=0.001 for each). Extensor moment of the knee joint was greater in the control group compared to the other two groups (p=0.003 and p=0.001, respectively). Walking velocity was higher in the control group compared to the severe hemophilia group. Kinetic and kinematic gait analysis has the sensitivity to detect minimal changes in biomechanical parameters. Gait analysis can be used as a reliable method to detect early joint damage.

  18. Motor Phenotype of Decline in Cognitive Performance among Community-Dwellers without Dementia: Population-Based Study and Meta-Analysis

    PubMed Central

    Beauchet, Olivier; Allali, Gilles; Montero-Odasso, Manuel; Sejdić, Ervin; Fantino, Bruno; Annweiler, Cédric

    2014-01-01

    Background Decline in cognitive performance is associated with gait deterioration. Our objectives were: 1) to determine, from an original study in older community-dwellers without diagnosis of dementia, which gait parameters, among slower gait speed, higher stride time variability (STV) and Timed Up & Go test (TUG) delta time, were most strongly associated with lower performance in two cognitive domains (i.e., episodic memory and executive function); and 2) to quantitatively synthesize, with a systematic review and meta-analysis, the association between gait performance and cognitive decline (i.e., mild cognitive impairment (MCI) and dementia). Methods Based on a cross-sectional design, 934 older community-dwellers without dementia (mean±standard deviation, 70.3±4.9years; 52.1% female) were recruited. A score at 5 on the Short Mini-Mental State Examination defined low episodic memory performance. Low executive performance was defined by clock-drawing test errors. STV and gait speed were measured using GAITRite system. TUG delta time was calculated as the difference between the times needed to perform and to imagine the TUG. Then, a systematic Medline search was conducted in November 2013 using the Medical Subject Heading terms “Delirium,” “Dementia,” “Amnestic,” “Cognitive disorders” combined with “Gait” OR “Gait disorders, Neurologic” and “Variability.” Findings A total of 294 (31.5%) participants presented decline in cognitive performance. Higher STV, higher TUG delta time, and slower gait speed were associated with decline in episodic memory and executive performances (all P-values <0.001). The highest magnitude of association was found for higher STV (effect size  =  −0.74 [95% Confidence Interval (CI): −1.05;−0.43], among participants combining of decline in episodic memory and in executive performances). Meta-analysis underscored that higher STV represented a gait biomarker in patients with MCI (effect size  =  0.48 [95% CI: 0.30;0.65]) and dementia (effect size  = 1.06 [95% CI: 0.40;1.72]). Conclusion Higher STV appears to be a motor phenotype of cognitive decline. PMID:24911155

  19. Quantifying Parkinson's disease progression by simulating gait patterns

    NASA Astrophysics Data System (ADS)

    Cárdenas, Luisa; Martínez, Fabio; Atehortúa, Angélica; Romero, Eduardo

    2015-12-01

    Modern rehabilitation protocols of most neurodegenerative diseases, in particular the Parkinson Disease, rely on a clinical analysis of gait patterns. Currently, such analysis is highly dependent on both the examiner expertise and the type of evaluation. Development of evaluation methods with objective measures is then crucial. Physical models arise as a powerful alternative to quantify movement patterns and to emulate the progression and performance of specific treatments. This work introduces a novel quantification of the Parkinson disease progression using a physical model that accurately represents the main gait biomarker, the body Center of Gravity (CoG). The model tracks the whole gait cycle by a coupled double inverted pendulum that emulates the leg swinging for the single support phase and by a damper-spring System (SDP) that recreates both legs in contact with the ground for the double phase. The patterns generated by the proposed model are compared with actual ones learned from 24 subjects in stages 2,3, and 4. The evaluation performed demonstrates a better performance of the proposed model when compared with a baseline model(SP) composed of a coupled double pendulum and a mass-spring system. The Frechet distance measured differences between model estimations and real trajectories, showing for stages 2, 3 and 4 distances of 0.137, 0.155, 0.38 for the baseline and 0.07, 0.09, 0.29 for the proposed method.

  20. Analysis of gait symmetry during over-ground walking in children with autism spectrum disorder.

    PubMed

    Eggleston, Jeffrey D; Harry, John R; Hickman, Robbin A; Dufek, Janet S

    2017-06-01

    Gait symmetry is utilized as an indicator of neurologic function. Healthy gait often exhibits minimal asymmetries, while pathological gait exhibits exaggerated asymmetries. The purpose of this study was to examine symmetry of mechanical gait parameters during over-ground walking in children with Autism Spectrum Disorder (ASD). Kinematic and kinetic data were obtained from 10 children (aged 5-12 years) with ASD. The Model Statistic procedure (α=0.05) was used to compare gait related parameters between limbs. Analysis revealed children with ASD exhibit significant lower extremity joint position and ground reaction force asymmetries throughout the gait cycle. The observed asymmetries were unique for each subject. These data do not support previous research relative to gait symmetry in children with ASD. Many individuals with ASD do not receive physical therapy interventions, however, precision medicine based interventions emphasizing lower extremity asymmetries may improve gait function and improve performance during activities of daily living. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The Effects of Aging and Dual Tasking on Human Gait Complexity During Treadmill Walking: A Comparative Study Using Quantized Dynamical Entropy and Sample Entropy.

    PubMed

    Ahmadi, Samira; Wu, Christine; Sepehri, Nariman; Kantikar, Anuprita; Nankar, Mayur; Szturm, Tony

    2018-01-01

    Quantized dynamical entropy (QDE) has recently been proposed as a new measure to quantify the complexity of dynamical systems with the purpose of offering a better computational efficiency. This paper further investigates the viability of this method using five different human gait signals. These signals are recorded while normal walking and while performing secondary tasks among two age groups (young and older age groups). The results are compared with the outcomes of previously established sample entropy (SampEn) measure for the same signals. We also study how analyzing segmented and spatially and temporally normalized signal differs from analyzing whole data. Our findings show that human gait signals become more complex as people age and while they are cognitively loaded. Center of pressure (COP) displacement in mediolateral direction is the best signal for showing the gait changes. Moreover, the results suggest that by segmenting data, more information about intrastride dynamical features are obtained. Most importantly, QDE is shown to be a reliable measure for human gait complexity analysis.

  2. Mechanical energy estimation during walking: validity and sensitivity in typical gait and in children with cerebral palsy.

    PubMed

    Van de Walle, P; Hallemans, A; Schwartz, M; Truijen, S; Gosselink, R; Desloovere, K

    2012-02-01

    Gait efficiency in children with cerebral palsy is usually quantified by metabolic energy expenditure. Mechanical energy estimations, however, can be a valuable supplement as they can be assessed during gait analysis and plotted over the gait cycle, thus revealing information on timing and sources of increases in energy expenditure. Unfortunately, little information on validity and sensitivity exists. Three mechanical estimation approaches: (1) centre of mass (CoM) approach, (2) sum of segmental energies (SSE) approach and (3) integrated joint power approach, were validated against oxygen consumption and each other. Sensitivity was assessed in typical gait and in children with diplegia. CoM approach underestimated total energy expenditure and showed poor sensitivity. SSE approach overestimated energy expenditure and showed acceptable sensitivity. Validity and sensitivity were best in the integrated joint power approach. This method is therefore preferred for mechanical energy estimation in children with diplegia. However, mechanical energy should supplement, not replace metabolic energy, as total energy expended is not captured in any mechanical approach. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Accelerometry-based gait analysis, an additional objective approach to screen subjects at risk for falling.

    PubMed

    Senden, R; Savelberg, H H C M; Grimm, B; Heyligers, I C; Meijer, K

    2012-06-01

    This study investigated whether the Tinetti scale, as a subjective measure for fall risk, is associated with objectively measured gait characteristics. It is studied whether gait parameters are different for groups that are stratified for fall risk using the Tinetti scale. Moreover, the discriminative power of gait parameters to classify elderly according to the Tinetti scale is investigated. Gait of 50 elderly with a Tinneti>24 and 50 elderly with a Tinetti≤24 was analyzed using acceleration-based gait analysis. Validated algorithms were used to derive spatio-temporal gait parameters, harmonic ratio, inter-stride amplitude variability and root mean square (RMS) from the accelerometer data. Clear differences in gait were found between the groups. All gait parameters correlated with the Tinetti scale (r-range: 0.20-0.73). Only walking speed, step length and RMS showed moderate to strong correlations and high discriminative power to classify elderly according to the Tinetti scale. It is concluded that subtle gait changes that have previously been related to fall risk are not captured by the subjective assessment. It is therefore worthwhile to include objective gait assessment in fall risk screening. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Visual analysis of the effects of load carriage on gait

    NASA Astrophysics Data System (ADS)

    Wittman, Michael G.; Ward, James M.; Flynn, Patrick J.

    2005-03-01

    As early as the 1970's it was determined that gait, or the "manner of walking" is an identifying feature of a human being. Since then, extensive research has been done in the field of computer vision to determine how accurately a subject can be identified by gait characteristics. This has necessarily led to the study of how various data collection conditions, such as terrain type, varying camera angles, or a carried briefcase, may affect the identifying features of gait. However, little or no research has been done to question whether such conditions may be inferred from gait analysis. For example, is it possible to determine characteristics of the walking surface simply by looking at statistics derived from the subject's gait? The question to be addressed is whether significant concealed weight distributed on the subject's torso can be discovered through analysis of his gait. Individual trends in subjects in response to increasing concealed weight will be explored, with the objective of finding universal trends that would have obvious security purposes.

  5. Comparison of Rectified and Unrectified Sockets for Transtibial Amputees.

    PubMed

    Engsberg, Jack R; Sprouse, S Wayne; Uhrich, Mary L; Ziegler, Barbara R; Luitjohan, F Daniel

    2008-01-01

    The current method for fabricating prosthetic sockets is to modify a positive mold to account for the non-homogeneity of the residual limb to tolerate load (i.e., rectified socket). We tested unrectified sockets by retaining the shape of the residual limb, except for a distal end pad, using an alginate gel process instead of casting. This investigation compared rectified and unrectified sockets. Forty-three adults with unilateral transtibial amputations were tested after randomly wearing both rectified and unrectified sockets for at least 4 weeks. Testing included a gait analysis, energy expenditure and Prosthesis Evaluation Questionnaire (PEQ). Results indicated no differences between sockets for gait speed and timing, gait kinematics and kinetics, and gait energy expenditure. There were also no differences in the Prosthetic Evaluation Questionnaire and 16 subjects selected the rectified socket, 25 selected the unrectified socket, and 2 subjects selected to use both sockets as their exit socket. Results seemed to indicate that more than one paradigm exists for shaping prosthetic sockets, and this paradigm may be helpful in understanding the mechanisms of socket fit. The alginate gel fabrication method was simpler than the traditional method. The method could be helpful in other countries where prosthetic care is lacking, may be helpful with new amputees, and may be helpful in typical clinics to reduce costs and free the prosthetist to focus more time on patient needs.

  6. Comparison of Rectified and Unrectified Sockets for Transtibial Amputees

    PubMed Central

    Engsberg, Jack R.; Sprouse, S. Wayne; Uhrich, Mary L.; Ziegler, Barbara R.; Luitjohan, F. Daniel

    2008-01-01

    The current method for fabricating prosthetic sockets is to modify a positive mold to account for the non-homogeneity of the residual limb to tolerate load (i.e., rectified socket). We tested unrectified sockets by retaining the shape of the residual limb, except for a distal end pad, using an alginate gel process instead of casting. This investigation compared rectified and unrectified sockets. Forty-three adults with unilateral transtibial amputations were tested after randomly wearing both rectified and unrectified sockets for at least 4 weeks. Testing included a gait analysis, energy expenditure and Prosthesis Evaluation Questionnaire (PEQ). Results indicated no differences between sockets for gait speed and timing, gait kinematics and kinetics, and gait energy expenditure. There were also no differences in the Prosthetic Evaluation Questionnaire and 16 subjects selected the rectified socket, 25 selected the unrectified socket, and 2 subjects selected to use both sockets as their exit socket. Results seemed to indicate that more than one paradigm exists for shaping prosthetic sockets, and this paradigm may be helpful in understanding the mechanisms of socket fit. The alginate gel fabrication method was simpler than the traditional method. The method could be helpful in other countries where prosthetic care is lacking, may be helpful with new amputees, and may be helpful in typical clinics to reduce costs and free the prosthetist to focus more time on patient needs. PMID:18776945

  7. A Neural Network-Based Gait Phase Classification Method Using Sensors Equipped on Lower Limb Exoskeleton Robots

    PubMed Central

    Jung, Jun-Young; Heo, Wonho; Yang, Hyundae; Park, Hyunsub

    2015-01-01

    An exact classification of different gait phases is essential to enable the control of exoskeleton robots and detect the intentions of users. We propose a gait phase classification method based on neural networks using sensor signals from lower limb exoskeleton robots. In such robots, foot sensors with force sensing registers are commonly used to classify gait phases. We describe classifiers that use the orientation of each lower limb segment and the angular velocities of the joints to output the current gait phase. Experiments to obtain the input signals and desired outputs for the learning and validation process are conducted, and two neural network methods (a multilayer perceptron and nonlinear autoregressive with external inputs (NARX)) are used to develop an optimal classifier. Offline and online evaluations using four criteria are used to compare the performance of the classifiers. The proposed NARX-based method exhibits sufficiently good performance to replace foot sensors as a means of classifying gait phases. PMID:26528986

  8. A Neural Network-Based Gait Phase Classification Method Using Sensors Equipped on Lower Limb Exoskeleton Robots.

    PubMed

    Jung, Jun-Young; Heo, Wonho; Yang, Hyundae; Park, Hyunsub

    2015-10-30

    An exact classification of different gait phases is essential to enable the control of exoskeleton robots and detect the intentions of users. We propose a gait phase classification method based on neural networks using sensor signals from lower limb exoskeleton robots. In such robots, foot sensors with force sensing registers are commonly used to classify gait phases. We describe classifiers that use the orientation of each lower limb segment and the angular velocities of the joints to output the current gait phase. Experiments to obtain the input signals and desired outputs for the learning and validation process are conducted, and two neural network methods (a multilayer perceptron and nonlinear autoregressive with external inputs (NARX)) are used to develop an optimal classifier. Offline and online evaluations using four criteria are used to compare the performance of the classifiers. The proposed NARX-based method exhibits sufficiently good performance to replace foot sensors as a means of classifying gait phases.

  9. Orthopaedic Application Of Spatio Temporal Analysis Of Body Form And Function

    NASA Astrophysics Data System (ADS)

    Tauber, C.; Au, J.; Bernstein, S.; Grant, A.; Pugh, J.

    1983-07-01

    Spatial and temporal analysis of walking provides the orthopaedist with objective evidence of functional ability and improvement in a patient. Patients with orthopaedic problems experiencing extreme pain and, consequently, irregularities in joint motions on weightbearing are videorecorded before, during and after a course of rehabilitative treatment and/or surgical correction of their disability. A specially-programmed computer analyzes these tapes for the parameters of walking by locating reflective spots which indicate the centers of the lower limb joints. The following parameters of gait are then generated: dynamic hip, knee and foot angles at various intervals during walking; vertical, horizontal and lateral displacements of each joint at various time intervals; linear and angular velocities of each joint; and the relationships between the joints during various phases of the gait cycle. The systematic sampling and analysis of the videorecordings by computer enable such information to be converted into and presented as computer graphics, as well as organized into tables of gait variables. This format of presentation of the skeletal adjustments involved in normal human motion provides the clinician with a visual format of gait information which objectively illuminates the multifaceted and complex factors involved. This system provides the clinician a method by which to evaluate the success of the regimen in terms of patient comfort and function.

  10. When human walking becomes random walking: fractal analysis and modeling of gait rhythm fluctuations

    NASA Astrophysics Data System (ADS)

    Hausdorff, Jeffrey M.; Ashkenazy, Yosef; Peng, Chang-K.; Ivanov, Plamen Ch.; Stanley, H. Eugene; Goldberger, Ary L.

    2001-12-01

    We present a random walk, fractal analysis of the stride-to-stride fluctuations in the human gait rhythm. The gait of healthy young adults is scale-free with long-range correlations extending over hundreds of strides. This fractal scaling changes characteristically with maturation in children and older adults and becomes almost completely uncorrelated with certain neurologic diseases. Stochastic modeling of the gait rhythm dynamics, based on transitions between different “neural centers”, reproduces distinctive statistical properties of the gait pattern. By tuning one model parameter, the hopping (transition) range, the model can describe alterations in gait dynamics from childhood to adulthood - including a decrease in the correlation and volatility exponents with maturation.

  11. Recommended number of strides for automatic assessment of gait symmetry and regularity in above-knee amputees by means of accelerometry and autocorrelation analysis

    PubMed Central

    2012-01-01

    Background Symmetry and regularity of gait are essential outcomes of gait retraining programs, especially in lower-limb amputees. This study aims presenting an algorithm to automatically compute symmetry and regularity indices, and assessing the minimum number of strides for appropriate evaluation of gait symmetry and regularity through autocorrelation of acceleration signals. Methods Ten transfemoral amputees (AMP) and ten control subjects (CTRL) were studied. Subjects wore an accelerometer and were asked to walk for 70 m at their natural speed (twice). Reference values of step and stride regularity indices (Ad1 and Ad2) were obtained by autocorrelation analysis of the vertical and antero-posterior acceleration signals, excluding initial and final strides. The Ad1 and Ad2 coefficients were then computed at different stages by analyzing increasing portions of the signals (considering both the signals cleaned by initial and final strides, and the whole signals). At each stage, the difference between Ad1 and Ad2 values and the corresponding reference values were compared with the minimum detectable difference, MDD, of the index. If that difference was less than MDD, it was assumed that the portion of signal used in the analysis was of sufficient length to allow reliable estimation of the autocorrelation coefficient. Results All Ad1 and Ad2 indices were lower in AMP than in CTRL (P < 0.0001). Excluding initial and final strides from the analysis, the minimum number of strides needed for reliable computation of step symmetry and stride regularity was about 2.2 and 3.5, respectively. Analyzing the whole signals, the minimum number of strides increased to about 15 and 20, respectively. Conclusions Without the need to identify and eliminate the phases of gait initiation and termination, twenty strides can provide a reasonable amount of information to reliably estimate gait regularity in transfemoral amputees. PMID:22316184

  12. Dynamic leg length asymmetry during gait is not a valid method for estimating mild anatomic leg length discrepancy.

    PubMed

    Leporace, Gustavo; Batista, Luiz Alberto; Serra Cruz, Raphael; Zeitoune, Gabriel; Cavalin, Gabriel Armondi; Metsavaht, Leonardo

    2018-03-01

    The purpose of this study was to test the validity of dynamic leg length discrepancy (DLLD) during gait as a radiation-free screening method for measuring anatomic leg length discrepancy (ALLD). Thirty-three subjects with mild leg length discrepancy walked along a walkway and the dynamic leg length discrepancy (DLLD) was calculated using a motion analysis system. Pearson correlation and paired Student t -tests were applied to calculate the correlation and compare the differences between DLLD and ALLD (α = 0.05). The results of our study showed DLLD is not a valid method to predict ALLD in subjects with mild limb discrepancy.

  13. Gait analysis in children with haemophilia: first Italian experience at the Turin Haemophilia Centre.

    PubMed

    Forneris, E; Andreacchio, A; Pollio, B; Mannucci, C; Franchini, M; Mengoli, C; Pagliarino, M; Messina, M

    2016-05-01

    To investigate the functional status in haemophilia patients referred to an Italian paediatric haemophilia centre using gait analysis, verifying any differences between mild, moderate or severe haemophilia at a functional level. Forty-two patients (age 4-18) presenting to the Turin Paediatric Haemophilia Centre who could walk independently were included. Therapy included prophylaxis (n = 21), on-demand (n = 17) or immune tolerance induction + inhibitor (n = 4). Patients performed a test of gait analysis. Temporal, spatial and kinematic parameters were calculated for patient subgroups by disease severity and background treatment, and compared with normal values. Moderate (35.7%) or severe (64.3%) haemophilia patients showed obvious variations from normal across a variety of temporal and spatial gait analysis parameters, including step speed and length, double support, swing phase, load asymmetry, stance phase, swing phase and speed. Kinematic parameters were characterized by frequent foot external rotation with deficient plantar flexion during the stance phase, retropelvic tilt, impaired power generation distally and reduced ground reaction forces. Both Gait Deviation Index and Gait Profile Score values for severe haemophilia patients indicated abnormal gait parameters, which were worst in patients with a history of past or current use of inhibitors and those receiving on-demand therapy. Functional evaluation identified changes in gait pattern in patients with severe and moderate haemophilia, compared with normal values. Gait analysis may be a useful tool to facilitate early diagnosis of joint damage, prevent haemophilic arthropathy, design a personalized rehabilitative treatment and monitor functional status over time. © 2016 John Wiley & Sons Ltd.

  14. Probabilistic Gait Classification in Children with Cerebral Palsy: A Bayesian Approach

    ERIC Educational Resources Information Center

    Van Gestel, Leen; De Laet, Tinne; Di Lello, Enrico; Bruyninckx, Herman; Molenaers, Guy; Van Campenhout, Anja; Aertbelien, Erwin; Schwartz, Mike; Wambacq, Hans; De Cock, Paul; Desloovere, Kaat

    2011-01-01

    Three-dimensional gait analysis (3DGA) generates a wealth of highly variable data. Gait classifications help to reduce, simplify and interpret this vast amount of 3DGA data and thereby assist and facilitate clinical decision making in the treatment of CP. CP gait is often a mix of several clinically accepted distinct gait patterns. Therefore,…

  15. Generating high-speed dynamic running gaits in a quadruped robot using an evolutionary search.

    PubMed

    Krasny, Darren P; Orin, David E

    2004-08-01

    Over the past several decades, there has been a considerable interest in investigating high-speed dynamic gaits for legged robots. While much research has been published, both in the biomechanics and engineering fields regarding the analysis of these gaits, no single study has adequately characterized the dynamics of high-speed running as can be achieved in a realistic, yet simple, robotic system. The goal of this paper is to find the most energy-efficient, natural, and unconstrained gallop that can be achieved using a simulated quadrupedal robot with articulated legs, asymmetric mass distribution, and compliant legs. For comparison purposes, we also implement the bound and canter. The model used here is planar, although we will show that it captures much of the predominant dynamic characteristics observed in animals. While it is not our goal to prove anything about biological locomotion, the dynamic similarities between the gaits we produce and those found in animals does indicate a similar underlying dynamic mechanism. Thus, we will show that achieving natural, efficient high-speed locomotion is possible even with a fairly simple robotic system. To generate the high-speed gaits, we use an efficient evolutionary algorithm called set-based stochastic optimization. This algorithm finds open-loop control parameters to generate periodic trajectories for the body. Several alternative methods are tested to generate periodic trajectories for the legs. The combined solutions found by the evolutionary search and the periodic-leg methods, over a range of speeds up to 10.0 m/s, reveal "biological" characteristics that are emergent properties of the underlying gaits.

  16. Real-Time Classification of Patients with Balance Disorders vs. Normal Subjects Using a Low-Cost Small Wireless Wearable Gait Sensor.

    PubMed

    Nukala, Bhargava Teja; Nakano, Taro; Rodriguez, Amanda; Tsay, Jerry; Lopez, Jerry; Nguyen, Tam Q; Zupancic, Steven; Lie, Donald Y C

    2016-11-29

    Gait analysis using wearable wireless sensors can be an economical, convenient and effective way to provide diagnostic and clinical information for various health-related issues. In this work, our custom designed low-cost wireless gait analysis sensor that contains a basic inertial measurement unit (IMU) was used to collect the gait data for four patients diagnosed with balance disorders and additionally three normal subjects, each performing the Dynamic Gait Index (DGI) tests while wearing the custom wireless gait analysis sensor (WGAS). The small WGAS includes a tri-axial accelerometer integrated circuit (IC), two gyroscopes ICs and a Texas Instruments (TI) MSP430 microcontroller and is worn by each subject at the T4 position during the DGI tests. The raw gait data are wirelessly transmitted from the WGAS to a near-by PC for real-time gait data collection and analysis. In order to perform successful classification of patients vs. normal subjects, we used several different classification algorithms, such as the back propagation artificial neural network (BP-ANN), support vector machine (SVM), k -nearest neighbors (KNN) and binary decision trees (BDT), based on features extracted from the raw gait data of the gyroscopes and accelerometers. When the range was used as the input feature, the overall classification accuracy obtained is 100% with BP-ANN, 98% with SVM, 96% with KNN and 94% using BDT. Similar high classification accuracy results were also achieved when the standard deviation or other values were used as input features to these classifiers. These results show that gait data collected from our very low-cost wearable wireless gait sensor can effectively differentiate patients with balance disorders from normal subjects in real time using various classifiers, the success of which may eventually lead to accurate and objective diagnosis of abnormal human gaits and their underlying etiologies in the future, as more patient data are being collected.

  17. Correlations among measures of knee stiffness, gait performance and complaints in individuals with knee osteoarthritis.

    PubMed

    Oatis, Carol A; Wolff, Edward F; Lockard, Margery A; Michener, Lori A; Robbins, Steven J

    2013-03-01

    Stiffness is a common complaint in individuals with knee osteoarthritis and is a component of the osteoarthritis diagnosis. Yet the relationship between stiffness and function is poorly understood and methods to quantify stiffness are limited. Using a cross-sectional observational design with 66 subjects with knee osteoarthritis, stiffness and damping coefficients were calculated from a relaxed knee oscillation procedure. Gait parameters were measured using an electronic walkway. Self-reported pain, stiffness, and function were measured with the Western Ontario and McMaster Osteoarthritis Index. Correlation and Alexander's normalized-t approximation analyses were used to assess associations among the variables. Subset analysis was performed on subjects with and without tibiofemoral joint crepitus. Slight to moderate correlations existed between stiffness and damping coefficients and most gait parameters ((| r |=0.30-0.56; P<.05) and between Western Ontario and McMaster Osteoarthritis Index scores and all gait parameters (| r |=0.35-0.62; P<.05). The damping coefficient was only slightly associated with patient-rated Western Ontario and McMaster Osteoarthritis Index stiffness subscale scores. Subset analysis revealed significant correlations that differed between those with and without crepitus. These findings suggest that laboratory measured stiffness and damping coefficients, Western Ontario and McMaster Osteoarthritis Index scores and gait-related measurements assess different aspects related to movement in individuals with knee osteoarthritis. Stiffness and damping coefficients may offer the ability to explain gait changes in the knee that are independent of a person's perceptions particularly in the early stages of the disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Technological Advances in Interventions to Enhance Post-Stroke Gait

    PubMed Central

    Sheffler, Lynne R.; Chae, John

    2012-01-01

    Synopsis This article provides a comprehensive review of specific rehabilitation interventions used to enhance hemiparetic gait following stroke. Neurologic rehabilitation interventions may be either therapeutic resulting in enhanced motor recovery or compensatory whereby assistance or substitution for neurological deficits results in improved functional performance. Included in this review are lower extremity functional electrical stimulation (FES), body-weight supported treadmill training (BWSTT), and lower extremity robotic-assisted gait training. These post-stroke gait training therapies are predicated on activity-dependent neuroplasticity which is the concept that cortical reorganization following central nervous system injury may be induced by repetitive, skilled, and cognitively engaging active movement. All three interventions have been trialed extensively in both research and clinical settings to demonstrate a positive effect on various gait parameters and measures of walking performance. However, more evidence is necessary to determine if specific technology-enhanced gait training methods are superior to conventional gait training methods. This review provides an overview of evidence-based research which supports the efficacy of these three interventions to improve gait, as well as provide perspective on future developments to enhance post-stroke gait in neurologic rehabilitation. PMID:23598265

  19. The Gait Deviation Index Is Associated with Hip Muscle Strength and Patient-Reported Outcome in Patients with Severe Hip Osteoarthritis-A Cross-Sectional Study.

    PubMed

    Rosenlund, Signe; Holsgaard-Larsen, Anders; Overgaard, Søren; Jensen, Carsten

    2016-01-01

    The Gait Deviation Index summarizes overall gait 'quality', based on kinematic data from a 3-dimensional gait analysis. However, it is unknown which clinical outcomes may affect the Gait Deviation Index in patients with primary hip osteoarthritis. The aim of this study was to investigate associations between Gait Deviation Index as a measure of gait 'quality' and hip muscle strength and between Gait Deviation Index and patient-reported outcomes in patients with primary hip osteoarthritis. Forty-seven patients (34 males), aged 61.1 ± 6.7 years, with BMI 27.3 ± 3.4 (kg/m2) and with severe primary hip osteoarthritis underwent 3-dimensional gait analysis. Mean Gait Deviation Index, pain after walking and maximal isometric hip muscle strength (flexor, extensor, and abductor) were recorded. All patients completed the 'Physical Function Short-form of the Hip disability and Osteoarthritis Outcome Score (HOOS-Physical Function) and the Hip disability and Osteoarthritis Outcome Score subscales for pain (HOOS-Pain) and quality-of-life (HOOS-QOL). Mean Gait Deviation Index was positively associated with hip abduction strength (p<0.01, r = 0.40), hip flexion strength (p = 0.01, r = 0.37), HOOS-Physical Function (p<0.01, r = 0.41) HOOS-QOL (p<0.01, r = 0.41), and negatively associated with HOOS-Pain after walking (p<0.01, r = -0.45). Adjusting the analysis for walking speed did not affect the association. Patients with the strongest hip abductor and hip flexor muscles had the best gait 'quality'. Furthermore, patients with higher physical function, quality of life scores and lower pain levels demonstrated better gait 'quality'. These findings indicate that interventions aimed at improving hip muscle strength and pain management may to a moderate degree improve the overall gait 'quality' in patients with primary hip OA.

  20. Analysis of the Applicability of an Ankle-Foot Orthosis during Gait in Poststroke Patients

    PubMed Central

    Costa, Rafael Vital; Grecco, Luanda André Collange; Neto, Hugo Pasini; Franco de Moura, Renata Calhes; Correa, João Carlos Ferrari; Corrêa, Fernanda Ishida; Oliveira, Claudia Santos

    2013-01-01

    [Purpose] The aim of this study was to develop and assess the applicability of an experimental ankle-foot orthosis during gait in patients with hemiparesis. [Subjects and Methods] This was a noncontrolled cross-sectional study. Ten adult patients with hemiparesis but who were capable of independent gait were included in the study. Gait assessment was performed using two platforms (EMG System do Brasil), an electromyograph (EMG System do Brasil), and a video camera. The experimental orthosis consisted of a single piece that fit over the foot and 1/3 of the distal tibia and had a steel spring. [Results] There was greater activation of the rectus femoris and vastus lateralis muscles in the stance and mid-stance phases with the use of the experimental ankle-foot orthosis in comparison with the use of a polypropylene ankle-foot orthosis and no orthosis. Regarding spatial and temporal gait parameters, the individuals achieved an increase in stride length with the use of the experimental ankle-foot orthosis in comparison with the use of a polypropylene ankle-foot orthosis. [Conclusion] The results of the present study demonstrate that individuals with hemiparesis achieved an improvement in the stance and mid-stance phases of gait with the use of the experimental ankle-foot orthosis. PMID:24259903

  1. Accuracy and reliability of observational gait analysis data: judgments of push-off in gait after stroke.

    PubMed

    McGinley, Jennifer L; Goldie, Patricia A; Greenwood, Kenneth M; Olney, Sandra J

    2003-02-01

    Physical therapists routinely observe gait in clinical practice. The purpose of this study was to determine the accuracy and reliability of observational assessments of push-off in gait after stroke. Eighteen physical therapists and 11 subjects with hemiplegia following a stroke participated in the study. Measurements of ankle power generation were obtained from subjects following stroke using a gait analysis system. Concurrent videotaped gait performances were observed by the physical therapists on 2 occasions. Ankle power generation at push-off was scored as either normal or abnormal using two 11-point rating scales. These observational ratings were correlated with the measurements of peak ankle power generation. A high correlation was obtained between the observational ratings and the measurements of ankle power generation (mean Pearson r=.84). Interobserver reliability was moderately high (mean intraclass correlation coefficient [ICC (2,1)]=.76). Intraobserver reliability also was high, with a mean ICC (2,1) of.89 obtained. Physical therapists were able to make accurate and reliable judgments of push-off in videotaped gait of subjects following stroke using observational assessment. Further research is indicated to explore the accuracy and reliability of data obtained with observational gait analysis as it occurs in clinical practice.

  2. Relationships between Isometric Muscle Strength, Gait Parameters, and Gross Motor Function Measure in Patients with Cerebral Palsy

    PubMed Central

    Shin, Hyung-Ik; Sung, Ki Hyuk; Chung, Chin Youb; Lee, Kyoung Min; Lee, Seung Yeol; Lee, In Hyeok

    2016-01-01

    Purpose This study investigated the correlation between isometric muscle strength, gross motor function, and gait parameters in patients with spastic cerebral palsy and to find which muscle groups play an important role for gait pattern in a flexed knee gait. Materials and Methods Twenty-four ambulatory patients (mean age, 10.0 years) with spastic cerebral palsy who were scheduled for single event multilevel surgery, including distal hamstring lengthening, were included. Preoperatively, peak isometric muscle strength was measured for the hip flexor, hip extensor, knee flexor, and knee extensor muscle groups using a handheld dynamometer, and three-dimensional (3D) gait analysis and gross motor function measure (GMFM) scoring were also performed. Correlations between peak isometric strength and GMFM, gait kinematics, and gait kinetics were analyzed. Results Peak isometric muscle strength of all muscle groups was not related to the GMFM score and the gross motor function classification system level. Peak isometric strength of the hip extensor and knee extensor was significantly correlated with the mean pelvic tilt (r=-0.588, p=0.003 and r=-0.436, p=0.033) and maximum pelvic obliquity (r=-0.450, p=0.031 and r=-0.419, p=0.041). There were significant correlations between peak isometric strength of the knee extensor and peak knee extensor moment in early stance (r=0.467, p=0.021) and in terminal stance (r=0.416, p=0.043). Conclusion There is no correlation between muscle strength and gross motor function. However, this study showed that muscle strength, especially of the extensor muscle group of the hip and knee joints, might play a critical role in gait by stabilizing pelvic motion and decreasing energy consumption in a flexed knee gait. PMID:26632404

  3. A model of free-living gait: A factor analysis in Parkinson's disease.

    PubMed

    Morris, Rosie; Hickey, Aodhán; Del Din, Silvia; Godfrey, Alan; Lord, Sue; Rochester, Lynn

    2017-02-01

    Gait is a marker of global health, cognition and falls risk. Gait is complex, comprised of multiple characteristics sensitive to survival, age and pathology. Due to covariance amongst characteristics, conceptual gait models have been established to reduce redundancy and aid interpretation. Previous models have been derived from laboratory gait assessments which are costly in equipment and time. Body-worn monitors (BWM) allow for free-living, low-cost and continuous gait measurement and produce similar covariant gait characteristics. A BWM gait model from both controlled and free-living measurement has not yet been established, limiting utility. 103 control and 67 PD participants completed a controlled laboratory assessment; walking for two minutes around a circuit wearing a BWM. 89 control and 58 PD participants were assessed in free-living, completing normal activities for 7 days wearing a BWM. Fourteen gait characteristics were derived from the BWM, selected according to a previous model. Principle component analysis derived factor loadings of gait characteristics. Four gait domains were derived for both groups and conditions; pace, rhythm, variability and asymmetry. Domains totalled 84.84% and 88.43% of variance for controlled and 90.00% and 93.03% of variance in free-living environments for control and PD participants respectively. Gait characteristic loading was unambiguous for all characteristics apart from gait variability which demonstrated cross-loading for both groups and environments. The model was highly congruent with the original model. The conceptual gait models remained stable using a BWM in controlled and free-living environments. The model became more discrete supporting utility of the gait model for free-living gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Characterizing left-right gait balance using footstep-induced structural vibrations

    NASA Astrophysics Data System (ADS)

    Fagert, Jonathon; Mirshekari, Mostafa; Pan, Shijia; Zhang, Pei; Noh, Hae Young

    2017-04-01

    In this paper, we introduce a method for estimating human left/right walking gait balance using footstep-induced structural vibrations. Understanding human gait balance is an integral component of assessing gait, neurological and musculoskeletal conditions, overall health status, and risk of falls. Existing techniques utilize pressure- sensing mats, wearable devices, and human observation-based assessment by healthcare providers. These existing methods are collectively limited in their operation and deployment; often requiring dense sensor deployment or direct user interaction. To address these limitations, we utilize footstep-induced structural vibration responses. Based on the physical insight that the vibration energy is a function of the force exerted by a footstep, we calculate the vibration signal energy due to a footstep and use it to estimate the footstep force. By comparing the footstep forces while walking, we determine balance. This approach enables non-intrusive gait balance assessment using sparsely deployed sensors. The primary research challenge is that the floor vibration signal energy is also significantly affected by the distance between the footstep location and the vibration sensor; this function is unclear in real-world scenarios and is a mixed function of wave propagation and structure-dependent properties. We overcome this challenge through footstep localization and incorporating structural factors into an analytical force-energy-distance function. This function is estimated through a nonlinear least squares regression analysis. We evaluate the performance of our method with a real-world deployment in a campus building. Our approach estimates footstep forces with a RMSE of 61.0N (8% of participant's body weight), representing a 1.54X improvement over the baseline.

  5. A fault tolerant gait for a hexapod robot over uneven terrain.

    PubMed

    Yang, J M; Kim, J H

    2000-01-01

    The fault tolerant gait of legged robots in static walking is a gait which maintains its stability against a fault event preventing a leg from having the support state. In this paper, a fault tolerant quadruped gait is proposed for a hexapod traversing uneven terrain with forbidden regions, which do not offer viable footholds but can be stepped over. By comparing performance of straight-line motion and crab walking over even terrain, it is shown that the proposed gait has better mobility and terrain adaptability than previously developed gaits. Based on the proposed gait, we present a method for the generation of the fault tolerant locomotion of a hexapod over uneven terrain with forbidden regions. The proposed method minimizes the number of legs on the ground during walking, and foot adjustment algorithm is used for avoiding steps on forbidden regions. The effectiveness of the proposed strategy over uneven terrain is demonstrated with a computer simulation.

  6. Dynamic Simulation and Analysis of Human Walking Mechanism

    NASA Astrophysics Data System (ADS)

    Azahari, Athirah; Siswanto, W. A.; Ngali, M. Z.; Salleh, S. Md.; Yusup, Eliza M.

    2017-01-01

    Behaviour such as gait or posture may affect a person with the physiological condition during daily activities. The characteristic of human gait cycle phase is one of the important parameter which used to described the human movement whether it is in normal gait or abnormal gait. This research investigates four types of crouch walking (upright, interpolated, crouched and severe) by simulation approach. The assessment are conducting by looking the parameters of hamstring muscle joint, knee joint and ankle joint. The analysis results show that based on gait analysis approach, the crouch walking have a weak pattern of walking and postures. Short hamstring and knee joint is the most influence factor contributing to the crouch walking due to excessive hip flexion that typically accompanies knee flexion.

  7. Gait patterns comparison of children with Duchenne muscular dystrophy to those of control subjects considering the effect of gait velocity.

    PubMed

    Gaudreault, Nathaly; Gravel, Denis; Nadeau, Sylvie; Houde, Sylvie; Gagnon, Denis

    2010-07-01

    3D analysis of the gait of children with Duchenne muscular dystrophy (DMD) was the topic of only a few studies and none of these considered the effect of gait velocity on the gait parameters of children with DMD. Gait parameters of 11 children with DMD were compared to those of 14 control children while considering the effect of gait velocity using 3D biomechanical analysis. Kinematic and kinetic gait parameters were measured using an Optotrak motion analysis system and AMTI force plates embedded in the floor. The data profiles of children with DMD walking at natural gait velocity were compared to those of the control children who walked at both natural and slow gait velocities. When both groups walked at similar velocity, children with DMD had higher cadence and shorter step length. They demonstrated a lower hip extension moment as well as a minimal or absent knee extension moment. At the ankle, a dorsiflexion moment was absent at heel strike due to the anterior location of the center of pressure. The magnitude of the medio-lateral ground reaction force was higher in children with DMD. Despite this increase, the hip abductor moment was lower. Hip power generation was also observed at the mid-stance in DMD children. These results suggest that most of the modifications observed are strategies used by children with DMD to cope with possible muscle weakness in order to provide support, propulsion and balance of the body during gait. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. FreeWalker: a smart insole for longitudinal gait analysis.

    PubMed

    Wang, Baitong; Rajput, Kuldeep Singh; Tam, Wing-Kin; Tung, Anthony K H; Yang, Zhi

    2015-08-01

    Gait analysis is an important diagnostic measure to investigate the pattern of walking. Traditional gait analysis is generally carried out in a gait lab, with equipped force and body tracking sensors, which needs a trained medical professional to interpret the results. This procedure is tedious, expensive, and unreliable and makes it difficult to track the progress across multiple visits. In this paper, we present a smart insole called FreeWalker, which provides quantitative gait analysis outside the confinement of traditional lab, at low- cost. The insole consists of eight pressure sensors and two motion tracking sensors, i.e. 3-axis accelerometer and 3-axis gyroscope. This enables measurement of under-foot pressure distribution and motion sequences in real-time. The insole is enabled with onboard SD card as well as wireless data transmission, which help in continuous gait-cycle analysis. The data is then sent to a gateway, for analysis and interpretation of data, using a user interface where gait features are graphically displayed. We also present validation result of a subject's left foot, who was asked to perform a specific task. Experiment results show that we could achieve a data-sampling rate of over 1 KHz, transmitting data up to a distance of 20 meter and maintain a battery life of around 24 hours. Taking advantage of these features, FreeWalker can be used in various applications, like medical diagnosis, rehabilitation, sports and entertainment.

  9. A machine learning approach for gait speed estimation using skin-mounted wearable sensors: From healthy controls to individuals with multiple sclerosis.

    PubMed

    McGinnis, Ryan S; Mahadevan, Nikhil; Moon, Yaejin; Seagers, Kirsten; Sheth, Nirav; Wright, John A; DiCristofaro, Steven; Silva, Ikaro; Jortberg, Elise; Ceruolo, Melissa; Pindado, Jesus A; Sosnoff, Jacob; Ghaffari, Roozbeh; Patel, Shyamal

    2017-01-01

    Gait speed is a powerful clinical marker for mobility impairment in patients suffering from neurological disorders. However, assessment of gait speed in coordination with delivery of comprehensive care is usually constrained to clinical environments and is often limited due to mounting demands on the availability of trained clinical staff. These limitations in assessment design could give rise to poor ecological validity and limited ability to tailor interventions to individual patients. Recent advances in wearable sensor technologies have fostered the development of new methods for monitoring parameters that characterize mobility impairment, such as gait speed, outside the clinic, and therefore address many of the limitations associated with clinical assessments. However, these methods are often validated using normal gait patterns; and extending their utility to subjects with gait impairments continues to be a challenge. In this paper, we present a machine learning method for estimating gait speed using a configurable array of skin-mounted, conformal accelerometers. We establish the accuracy of this technique on treadmill walking data from subjects with normal gait patterns and subjects with multiple sclerosis-induced gait impairments. For subjects with normal gait, the best performing model systematically overestimates speed by only 0.01 m/s, detects changes in speed to within less than 1%, and achieves a root-mean-square-error of 0.12 m/s. Extending these models trained on normal gait to subjects with gait impairments yields only minor changes in model performance. For example, for subjects with gait impairments, the best performing model systematically overestimates speed by 0.01 m/s, quantifies changes in speed to within 1%, and achieves a root-mean-square-error of 0.14 m/s. Additional analyses demonstrate that there is no correlation between gait speed estimation error and impairment severity, and that the estimated speeds maintain the clinical significance of ground truth speed in this population. These results support the use of wearable accelerometer arrays for estimating walking speed in normal subjects and their extension to MS patient cohorts with gait impairment.

  10. Gait pattern of severely disabled hemiparetic subjects on a new controlled gait trainer as compared to assisted treadmill walking with partial body weight support.

    PubMed

    Hesse, S; Uhlenbrock, D; Sarkodie-Gyan, T

    1999-10-01

    To investigate to what extent and with how much therapeutic effort nonambulatory stroke patients could train a gait-like movement on a newly developed, machine-supported gait trainer. Open study comparing the movement on the gait trainer with assisted walking on the treadmill. Motion analysis laboratory of a rehabilitation centre. Fourteen chronic, nonambulatory hemiparetic patients. Complex gait analysis while training on the gait trainer and while walking on the treadmill. Gait kinematics, kinesiological EMG of several lower limb muscles and the required assistance. Patients could train a gait-like movement on the gait trainer, characterized kinematically by a perfect symmetry, larger hip extension during stance, less knee flexion and less ankle plantar flexion during swing as compared to treadmill walking (p <0.01). The pattern and amount of activation of relevant weight-bearing muscles was comparable with an even larger activation of the M. biceps femoris on the gait trainer (p <0.01). The tibialis anterior muscle of the nonaffected side, however, was less activated during swing (p <0.01). Two therapists assisted walking on the treadmill while only one therapist was necessary to help with weight shifting on the new device. The newly developed gait trainer offered severely disabled hemiparetic subjects the possibility of training a gait-like, highly symmetrical movement with a favourable facilitation of relevant anti-gravity muscles. At the same time, the effort required of the therapists was reduced.

  11. Effect of rhythmic auditory cueing on gait in cerebral palsy: a systematic review and meta-analysis.

    PubMed

    Ghai, Shashank; Ghai, Ishan; Effenberg, Alfred O

    2018-01-01

    Auditory entrainment can influence gait performance in movement disorders. The entrainment can incite neurophysiological and musculoskeletal changes to enhance motor execution. However, a consensus as to its effects based on gait in people with cerebral palsy is still warranted. A systematic review and meta-analysis were carried out to analyze the effects of rhythmic auditory cueing on spatiotemporal and kinematic parameters of gait in people with cerebral palsy. Systematic identification of published literature was performed adhering to Preferred Reporting Items for Systematic Reviews and Meta-Analyses and American Academy for Cerebral Palsy and Developmental Medicine guidelines, from inception until July 2017, on online databases: Web of Science, PEDro, EBSCO, Medline, Cochrane, Embase and ProQuest. Kinematic and spatiotemporal gait parameters were evaluated in a meta-analysis across studies. Of 547 records, nine studies involving 227 participants (108 children/119 adults) met our inclusion criteria. The qualitative review suggested beneficial effects of rhythmic auditory cueing on gait performance among all included studies. The meta-analysis revealed beneficial effects of rhythmic auditory cueing on gait dynamic index (Hedge's g =0.9), gait velocity (1.1), cadence (0.3), and stride length (0.5). This review for the first time suggests a converging evidence toward application of rhythmic auditory cueing to enhance gait performance and stability in people with cerebral palsy. This article details underlying neurophysiological mechanisms and use of cueing as an efficient home-based intervention. It bridges gaps in the literature, and suggests translational approaches on how rhythmic auditory cueing can be incorporated in rehabilitation approaches to enhance gait performance in people with cerebral palsy.

  12. Relationships of stroke patients' gait parameters with fear of falling.

    PubMed

    Park, Jin; Yoo, Ingyu

    2014-12-01

    [Purpose] The purpose of this study was to assess the correlation of gait parameters with fear of falling in stroke survivors. [Subjects] In total, 12 patients with stroke participated. [Methods] The subjects performed on a Biodex Gait Trainer 2 for 5 min to evaluate characteristic gait parameters. The kinematic gait parameters measured were gait speed, step cycle, step length, and time on each foot (step symmetry). All the subjects also completed a fall anxiety survey. [Results] Correlations between gait parameters and fear of falling scores were calculated. There was a moderate degree of correlation between fear of falling scores and the step cycle item of gait parameters. [Conclusions] According to our results, the step cycle gait parameter may be related to increased fall anxiety.

  13. Instrumented gait analysis: a measure of gait improvement by a wheeled walker in hospitalized geriatric patients.

    PubMed

    Schülein, Samuel; Barth, Jens; Rampp, Alexander; Rupprecht, Roland; Eskofier, Björn M; Winkler, Jürgen; Gaßmann, Karl-Günter; Klucken, Jochen

    2017-02-27

    In an increasing aging society, reduced mobility is one of the most important factors limiting activities of daily living and overall quality of life. The ability to walk independently contributes to the mobility, but is increasingly restricted by numerous diseases that impair gait and balance. The aim of this cross-sectional observation study was to examine whether spatio-temporal gait parameters derived from mobile instrumented gait analysis can be used to measure the gait stabilizing effects of a wheeled walker (WW) and whether these gait parameters may serve as surrogate marker in hospitalized patients with multifactorial gait and balance impairment. One hundred six patients (ages 68-95) wearing inertial sensor equipped shoes passed an instrumented walkway with and without gait support from a WW. The walkway assessed the risk of falling associated gait parameters velocity, swing time, stride length, stride time- and double support time variability. Inertial sensor-equipped shoes measured heel strike and toe off angles, and foot clearance. The use of a WW improved the risk of spatio-temporal parameters velocity, swing time, stride length and the sagittal plane associated parameters heel strike and toe off angles in all patients. First-time users (FTUs) showed similar gait parameter improvement patterns as frequent WW users (FUs). However, FUs with higher levels of gait impairment improved more in velocity, stride length and toe off angle compared to the FTUs. The impact of a WW can be quantified objectively by instrumented gait assessment. Thus, objective gait parameters may serve as surrogate markers for the use of walking aids in patients with gait and balance impairments.

  14. Identity Recognition Algorithm Using Improved Gabor Feature Selection of Gait Energy Image

    NASA Astrophysics Data System (ADS)

    Chao, LIANG; Ling-yao, JIA; Dong-cheng, SHI

    2017-01-01

    This paper describes an effective gait recognition approach based on Gabor features of gait energy image. In this paper, the kernel Fisher analysis combined with kernel matrix is proposed to select dominant features. The nearest neighbor classifier based on whitened cosine distance is used to discriminate different gait patterns. The approach proposed is tested on the CASIA and USF gait databases. The results show that our approach outperforms other state of gait recognition approaches in terms of recognition accuracy and robustness.

  15. Synthesis of walking sounds for alleviating gait disturbances in Parkinson's disease.

    PubMed

    Rodger, Matthew W M; Young, William R; Craig, Cathy M

    2014-05-01

    Managing gait disturbances in people with Parkinson's disease is a pressing challenge, as symptoms can contribute to injury and morbidity through an increased risk of falls. While drug-based interventions have limited efficacy in alleviating gait impairments, certain nonpharmacological methods, such as cueing, can also induce transient improvements to gait. The approach adopted here is to use computationally-generated sounds to help guide and improve walking actions. The first method described uses recordings of force data taken from the steps of a healthy adult which in turn were used to synthesize realistic gravel-footstep sounds that represented different spatio-temporal parameters of gait, such as step duration and step length. The second method described involves a novel method of sonifying, in real time, the swing phase of gait using real-time motion-capture data to control a sound synthesis engine. Both approaches explore how simple but rich auditory representations of action based events can be used by people with Parkinson's to guide and improve the quality of their walking, reducing the risk of falls and injury. Studies with Parkinson's disease patients are reported which show positive results for both techniques in reducing step length variability. Potential future directions for how these sound approaches can be used to manage gait disturbances in Parkinson's are also discussed.

  16. Quantifying prosthetic gait deviation using simple outcome measures

    PubMed Central

    Kark, Lauren; Odell, Ross; McIntosh, Andrew S; Simmons, Anne

    2016-01-01

    AIM: To develop a subset of simple outcome measures to quantify prosthetic gait deviation without needing three-dimensional gait analysis (3DGA). METHODS: Eight unilateral, transfemoral amputees and 12 unilateral, transtibial amputees were recruited. Twenty-eight able-bodied controls were recruited. All participants underwent 3DGA, the timed-up-and-go test and the six-minute walk test (6MWT). The lower-limb amputees also completed the Prosthesis Evaluation Questionnaire. Results from 3DGA were summarised using the gait deviation index (GDI), which was subsequently regressed, using stepwise regression, against the other measures. RESULTS: Step-length (SL), self-selected walking speed (SSWS) and the distance walked during the 6MWT (6MWD) were significantly correlated with GDI. The 6MWD was the strongest, single predictor of the GDI, followed by SL and SSWS. The predictive ability of the regression equations were improved following inclusion of self-report data related to mobility and prosthetic utility. CONCLUSION: This study offers a practicable alternative to quantifying kinematic deviation without the need to conduct complete 3DGA. PMID:27335814

  17. Flexed-knee gait in children with cerebral palsy.

    PubMed

    Church, C; Ge, J; Hager, S; Haumont, T; Lennon, N; Niiler, T; Hulbert, R; Miller, F

    2018-04-01

    Aims The purpose of this study was to evaluate the long-term outcome of adolescents with cerebral palsy who have undergone single-event multilevel surgery for a flexed-knee gait, followed into young adulthood using 3D motion analysis. Patients and Methods A total of 59 young adults with spastic cerebral palsy, with a mean age of 26 years (sd 3), were enrolled into the study in which their gait was compared with an evaluation that had taken place a mean of 12 years (sd 2) previously. At their visits during adolescence, the children walked with excessive flexion of the knee at initial contact and surgical or therapeutic interventions were not controlled between visits. Results Based on the change in flexed-knee gait over approximately ten years, improvements were seen in increased Gait Deviation Index (p < 0.001) and decreased flexion of the knee at initial contact (p < 0.001). Greater popliteal angle (p < 0.001), reduced Gross Motor Function Measure section D (p = 0.006), and reduced speed of gait (p = 0.007) suggested a mild decline in function. Quality-of-life measures showed that these patients fell within normal limits compared with typical young adults in areas other than physical function. Conclusion While some small significant changes were noted, little clinically significant change was seen in function and gait, with gross motor function maintained between adolescence and young adulthood. Cite this article: Bone Joint J 2018;100-B:549-56.

  18. Poor Gait Performance and Prediction of Dementia: Results From a Meta-Analysis.

    PubMed

    Beauchet, Olivier; Annweiler, Cédric; Callisaya, Michele L; De Cock, Anne-Marie; Helbostad, Jorunn L; Kressig, Reto W; Srikanth, Velandai; Steinmetz, Jean-Paul; Blumen, Helena M; Verghese, Joe; Allali, Gilles

    2016-06-01

    Poor gait performance predicts risk of developing dementia. No structured critical evaluation has been conducted to study this association yet. The aim of this meta-analysis was to systematically examine the association of poor gait performance with incidence of dementia. An English and French Medline search was conducted in June 2015, with no limit of date, using the medical subject headings terms "Gait" OR "Gait Disorders, Neurologic" OR "Gait Apraxia" OR "Gait Ataxia" AND "Dementia" OR "Frontotemporal Dementia" OR "Dementia, Multi-Infarct" OR "Dementia, Vascular" OR "Alzheimer Disease" OR "Lewy Body Disease" OR "Frontotemporal Dementia With Motor Neuron Disease" (Supplementary Concept). Poor gait performance was defined by standardized tests of walking, and dementia was diagnosed according to international consensus criteria. Four etiologies of dementia were identified: any dementia, Alzheimer disease (AD), vascular dementia (VaD), and non-AD (ie, pooling VaD, mixed dementias, and other dementias). Fixed effects meta-analyses were performed on the estimates in order to generate summary values. Of the 796 identified abstracts, 12 (1.5%) were included in this systematic review and meta-analysis. Poor gait performance predicted dementia [pooled hazard ratio (HR) combined with relative risk and odds ratio = 1.53 with P < .001 for any dementia, pooled HR = 1.79 with P < .001 for VaD, HR = 1.89 with P value < .001 for non-AD]. Findings were weaker for predicting AD (HR = 1.03 with P value = .004). This meta-analysis provides evidence that poor gait performance predicts dementia. This association depends on the type of dementia; poor gait performance is a stronger predictor of non-AD dementias than AD. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  19. Finite Element Analysis of a Highly Flexible Flapping Wing

    DTIC Science & Technology

    2013-03-01

    normal operating conditions the duck was powered by a rechargeable lithium- ion battery. Placing this battery in a vacuum could be potentially hazardous ...Figure 26. Wingtip trace for (a) albatross fast gait, (b) pigeon slow gait, (c) horseshoe bat fast gait, (d) horseshoe bat slow gait, (e) blowfly, (f

  20. The application of high-speed cinematography for the quantitative analysis of equine locomotion.

    PubMed

    Fredricson, I; Drevemo, S; Dalin, G; Hjertën, G; Björne, K

    1980-04-01

    Locomotive disorders constitute a serious problem in horse racing which will only be rectified by a better understanding of the causative factors associated with disturbances of gait. This study describes a system for the quantitative analysis of the locomotion of horses at speed. The method is based on high-speed cinematography with a semi-automatic system of analysis of the films. The recordings are made with a 16 mm high-speed camera run at 500 frames per second (fps) and the films are analysed by special film-reading equipment and a mini-computer. The time and linear gait variables are presented in tabular form and the angles and trajectories of the joints and body segments are presented graphically.

  1. Zero velocity interval detection based on a continuous hidden Markov model in micro inertial pedestrian navigation

    NASA Astrophysics Data System (ADS)

    Sun, Wei; Ding, Wei; Yan, Huifang; Duan, Shunli

    2018-06-01

    Shoe-mounted pedestrian navigation systems based on micro inertial sensors rely on zero velocity updates to correct their positioning errors in time, which effectively makes determining the zero velocity interval play a key role during normal walking. However, as walking gaits are complicated, and vary from person to person, it is difficult to detect walking gaits with a fixed threshold method. This paper proposes a pedestrian gait classification method based on a hidden Markov model. Pedestrian gait data are collected with a micro inertial measurement unit installed at the instep. On the basis of analyzing the characteristics of the pedestrian walk, a single direction angular rate gyro output is used to classify gait features. The angular rate data are modeled into a univariate Gaussian mixture model with three components, and a four-state left–right continuous hidden Markov model (CHMM) is designed to classify the normal walking gait. The model parameters are trained and optimized using the Baum–Welch algorithm and then the sliding window Viterbi algorithm is used to decode the gait. Walking data are collected through eight subjects walking along the same route at three different speeds; the leave-one-subject-out cross validation method is conducted to test the model. Experimental results show that the proposed algorithm can accurately detect different walking gaits of zero velocity interval. The location experiment shows that the precision of CHMM-based pedestrian navigation improved by 40% when compared to the angular rate threshold method.

  2. A semi-automated software tool to study treadmill locomotion in the rat: from experiment videos to statistical gait analysis.

    PubMed

    Gravel, P; Tremblay, M; Leblond, H; Rossignol, S; de Guise, J A

    2010-07-15

    A computer-aided method for the tracking of morphological markers in fluoroscopic images of a rat walking on a treadmill is presented and validated. The markers correspond to bone articulations in a hind leg and are used to define the hip, knee, ankle and metatarsophalangeal joints. The method allows a user to identify, using a computer mouse, about 20% of the marker positions in a video and interpolate their trajectories from frame-to-frame. This results in a seven-fold speed improvement in detecting markers. This also eliminates confusion problems due to legs crossing and blurred images. The video images are corrected for geometric distortions from the X-ray camera, wavelet denoised, to preserve the sharpness of minute bone structures, and contrast enhanced. From those images, the marker positions across video frames are extracted, corrected for rat "solid body" motions on the treadmill, and used to compute the positional and angular gait patterns. Robust Bootstrap estimates of those gait patterns and their prediction and confidence bands are finally generated. The gait patterns are invaluable tools to study the locomotion of healthy animals or the complex process of locomotion recovery in animals with injuries. The method could, in principle, be adapted to analyze the locomotion of other animals as long as a fluoroscopic imager and a treadmill are available. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Quantitative Balance and Gait Measurement in Patients with Frontotemporal Dementia and Alzheimer Diseases: A Pilot Study

    PubMed Central

    Velayutham, Selva Ganapathy; Chandra, Sadanandavalli Retnaswami; Bharath, Srikala; Shankar, Ravi Girikamatha

    2017-01-01

    Introduction: Alzhiemers disease and Frontotemporal dementia are common neurodegenerative dementias with a wide prevalence. Falls are a common cause of morbidity in these patients. Identifying subclinical involvement of these parameters might serve as a tool in differential analysis of these distinct parameters involved in these conditions and also help in planning preventive strategies to prevent falls. Patients and Methods: Eight patients in age and gender matched patients in each group were compared with normal controls. Standardizes methods of gait and balance aseesment were done in all persons. Results: Results revealed subclinical involvement of gait and balancesin all groups specially during divided attention. The parameters were significantly more affected in patients. Patients with AD and FTD had involement of over all ambulation index balance more affected in AD patients FTD patients showed step cycle, stride length abnormalities. Discussion: There is balance and gait involvement in normal ageing as well as patients with AD and FTD. The pattern of involvement in AD correlates with WHERE pathway involvement and FTD with frontal subcortical circuits involvement. Conclusion: Identification the differential patterns of involvement in subclinical stage might help to differentiate normal ageing and the different types of cortical dementias. This could serve as an additional biomarker and also assist in initiating appropriate training methods to prevent future falls. PMID:28515555

  4. Reliability of a Qualitative Video Analysis for Running.

    PubMed

    Pipkin, Andrew; Kotecki, Kristy; Hetzel, Scott; Heiderscheit, Bryan

    2016-07-01

    Study Design Reliability study. Background Video analysis of running gait is frequently performed in orthopaedic and sports medicine practices to assess biomechanical factors that may contribute to injury. However, the reliability of a whole-body assessment has not been determined. Objective To determine the intrarater and interrater reliability of the qualitative assessment of specific running kinematics from a 2-dimensional video. Methods Running-gait analysis was performed on videos recorded from 15 individuals (8 male, 7 female) running at a self-selected pace (3.17 ± 0.40 m/s, 8:28 ± 1:04 min/mi) using a high-speed camera (120 frames per second). These videos were independently rated on 2 occasions by 3 experienced physical therapists using a standardized qualitative assessment. Fifteen sagittal and frontal plane kinematic variables were rated on a 3- or 5-point categorical scale at specific events of the gait cycle, including initial contact (n = 3) and midstance (n = 9), or across the full gait cycle (n = 3). The video frame number corresponding to each gait event was also recorded. Intrarater and interrater reliability values were calculated for gait-event detection (intraclass correlation coefficient [ICC] and standard error of measurement [SEM]) and the individual kinematic variables (weighted kappa [κw]). Results Gait-event detection was highly reproducible within raters (ICC = 0.94-1.00; SEM, 0.3-1.0 frames) and between raters (ICC = 0.77-1.00; SEM, 0.4-1.9 frames). Eleven of the 15 kinematic variables demonstrated substantial (κw = 0.60-0.799) or excellent (κw>0.80) intrarater agreement, with the exception of foot-to-center-of-mass position (κw = 0.59), forefoot position (κw = 0.58), ankle dorsiflexion at midstance (κw = 0.49), and center-of-mass vertical excursion (κw = 0.36). Interrater agreement for the kinematic measures varied more widely (κw = 0.00-0.85), with 5 variables showing substantial or excellent reliability. Conclusion The qualitative assessment of specific kinematic measures during running can be reliably performed with the use of a high-speed video camera. Detection of specific gait events was highly reproducible, as were common kinematic variables such as rearfoot position, foot-strike pattern, tibial inclination angle, knee flexion angle, and forward trunk lean. Other variables should be used with caution. J Orthop Sports Phys Ther 2016;46(7):556-561. Epub 6 Jun 2016. doi:10.2519/jospt.2016.6280.

  5. Assessment of gait parameters and fatigue in MS patients during inpatient rehabilitation: a pilot trial.

    PubMed

    Sacco, Rosaria; Bussman, Rita; Oesch, Peter; Kesselring, Jürg; Beer, Serafin

    2011-05-01

    Gait impairment and fatigue are common and disabling problems in multiple sclerosis (MS). Characterisation of abnormal gait in MS patients has been done mainly using observational studies and simple walking tests providing only limited quantitative and no qualitative data, or using intricate and time-consuming assessment procedures. In addition, the correlation of gait impairments with fatigue is largely unknown. The aim of this study was to characterise spatio-temporal gait parameters by a simple and easy-to-use gait analysis system (GAITRite®) in MS patients compared with healthy controls, and to analyse changes and correlation with fatigue during inpatient rehabilitation. Twenty-four MS patients (EDSS <6.5) admitted for inpatient rehabilitation and 19 healthy subjects were evaluated using the GAITRite® Functional Ambulation System. Between-group differences and changes of gait parameters during inpatient rehabilitation were analysed, and correlation with fatigue, using the Wurzburg Fatigue Inventory for Multiple Sclerosis (WEIMuS), was determined. Compared to healthy controls MS patients showed significant impairments in different spatio-temporal gait parameters, which showed a significant improvement during inpatient rehabilitation. Different gait parameters were correlated with fatigue physical score, and change of gait parameters was correlated with improvement of fatigue. Spatio-temporal gait analysis is helpful to assess specific walking impairments in MS patients and subtle changes during rehabilitation. Correlation with fatigue may indicate a possible negative impact of fatigue on rehabilitation outcome.

  6. Feature extraction via KPCA for classification of gait patterns.

    PubMed

    Wu, Jianning; Wang, Jue; Liu, Li

    2007-06-01

    Automated recognition of gait pattern change is important in medical diagnostics as well as in the early identification of at-risk gait in the elderly. We evaluated the use of Kernel-based Principal Component Analysis (KPCA) to extract more gait features (i.e., to obtain more significant amounts of information about human movement) and thus to improve the classification of gait patterns. 3D gait data of 24 young and 24 elderly participants were acquired using an OPTOTRAK 3020 motion analysis system during normal walking, and a total of 36 gait spatio-temporal and kinematic variables were extracted from the recorded data. KPCA was used first for nonlinear feature extraction to then evaluate its effect on a subsequent classification in combination with learning algorithms such as support vector machines (SVMs). Cross-validation test results indicated that the proposed technique could allow spreading the information about the gait's kinematic structure into more nonlinear principal components, thus providing additional discriminatory information for the improvement of gait classification performance. The feature extraction ability of KPCA was affected slightly with different kernel functions as polynomial and radial basis function. The combination of KPCA and SVM could identify young-elderly gait patterns with 91% accuracy, resulting in a markedly improved performance compared to the combination of PCA and SVM. These results suggest that nonlinear feature extraction by KPCA improves the classification of young-elderly gait patterns, and holds considerable potential for future applications in direct dimensionality reduction and interpretation of multiple gait signals.

  7. A Machine Learning Approach to Automated Gait Analysis for the Noldus Catwalk System.

    PubMed

    Frohlich, Holger; Claes, Kasper; De Wolf, Catherine; Van Damme, Xavier; Michel, Anne

    2018-05-01

    Gait analysis of animal disease models can provide valuable insights into in vivo compound effects and thus help in preclinical drug development. The purpose of this paper is to establish a computational gait analysis approach for the Noldus Catwalk system, in which footprints are automatically captured and stored. We present a - to our knowledge - first machine learning based approach for the Catwalk system, which comprises a step decomposition, definition and extraction of meaningful features, multivariate step sequence alignment, feature selection, and training of different classifiers (gradient boosting machine, random forest, and elastic net). Using animal-wise leave-one-out cross validation we demonstrate that with our method we can reliable separate movement patterns of a putative Parkinson's disease animal model and several control groups. Furthermore, we show that we can predict the time point after and the type of different brain lesions and can even forecast the brain region, where the intervention was applied. We provide an in-depth analysis of the features involved into our classifiers via statistical techniques for model interpretation. A machine learning method for automated analysis of data from the Noldus Catwalk system was established. Our works shows the ability of machine learning to discriminate pharmacologically relevant animal groups based on their walking behavior in a multivariate manner. Further interesting aspects of the approach include the ability to learn from past experiments, improve with more data arriving and to make predictions for single animals in future studies.

  8. Predicting the probability of slip in gait: methodology and distribution study.

    PubMed

    Gragg, Jared; Yang, James

    2016-01-01

    The likelihood of a slip is related to the available and required friction for a certain activity, here gait. Classical slip and fall analysis presumed that a walking surface was safe if the difference between the mean available and required friction coefficients exceeded a certain threshold. Previous research was dedicated to reformulating the classical slip and fall theory to include the stochastic variation of the available and required friction when predicting the probability of slip in gait. However, when predicting the probability of a slip, previous researchers have either ignored the variation in the required friction or assumed the available and required friction to be normally distributed. Also, there are no published results that actually give the probability of slip for various combinations of required and available frictions. This study proposes a modification to the equation for predicting the probability of slip, reducing the previous equation from a double-integral to a more convenient single-integral form. Also, a simple numerical integration technique is provided to predict the probability of slip in gait: the trapezoidal method. The effect of the random variable distributions on the probability of slip is also studied. It is shown that both the required and available friction distributions cannot automatically be assumed as being normally distributed. The proposed methods allow for any combination of distributions for the available and required friction, and numerical results are compared to analytical solutions for an error analysis. The trapezoidal method is shown to be highly accurate and efficient. The probability of slip is also shown to be sensitive to the input distributions of the required and available friction. Lastly, a critical value for the probability of slip is proposed based on the number of steps taken by an average person in a single day.

  9. Hybridization between multi-objective genetic algorithm and support vector machine for feature selection in walker-assisted gait.

    PubMed

    Martins, Maria; Costa, Lino; Frizera, Anselmo; Ceres, Ramón; Santos, Cristina

    2014-03-01

    Walker devices are often prescribed incorrectly to patients, leading to the increase of dissatisfaction and occurrence of several problems, such as, discomfort and pain. Thus, it is necessary to objectively evaluate the effects that assisted gait can have on the gait patterns of walker users, comparatively to a non-assisted gait. A gait analysis, focusing on spatiotemporal and kinematics parameters, will be issued for this purpose. However, gait analysis yields redundant information that often is difficult to interpret. This study addresses the problem of selecting the most relevant gait features required to differentiate between assisted and non-assisted gait. For that purpose, it is presented an efficient approach that combines evolutionary techniques, based on genetic algorithms, and support vector machine algorithms, to discriminate differences between assisted and non-assisted gait with a walker with forearm supports. For comparison purposes, other classification algorithms are verified. Results with healthy subjects show that the main differences are characterized by balance and joints excursion in the sagittal plane. These results, confirmed by clinical evidence, allow concluding that this technique is an efficient feature selection approach. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Clinical implications of gait analysis in the rehabilitation of adult patients with "Prader-Willi" Syndrome: a cross-sectional comparative study ("Prader-Willi" Syndrome vs matched obese patients and healthy subjects)

    PubMed Central

    Vismara, Luca; Romei, Marianna; Galli, Manuela; Montesano, Angelo; Baccalaro, Gabriele; Crivellini, Marcello; Grugni, Graziano

    2007-01-01

    Background Being severely overweight is a distinctive clinical feature of Prader-Willi Syndrome (PWS). PWS is a complex multisystem disorder, representing the most common form of genetic obesity. The aim of this study was the analysis of the gait pattern of adult subjects with PWS by using three-Dimensional Gait Analysis. The results were compared with those obtained in a group of obese patients and in a group of healthy subjects. Methods Cross-sectional, comparative study: 19 patients with PWS (11 males and 8 females, age: 18–40 years, BMI: 29.3–50.3 kg/m2); 14 obese matched patients (5 males and 9 females, age: 18–40 years, BMI: 34.3–45.2 kg/m2); 20 healthy subjects (10 males and 10 females, age: 21–41 years, BMI: 19.3–25.4 kg/m2). Kinematic and kinetic parameters during walking were assessed by an optoelectronic system and two force platforms. Results PWS adult patients walked slower, had a shorter stride length, a lower cadence and a longer stance phase compared with both matched obese, and healthy subjects. Obese matched patients showed spatio-temporal parameters significantly different from healthy subjects. Furthermore, Range Of Motion (ROM) at knee and ankle, and plantaflexor activity of PWS patients were significantly different between obese and healthy subjects. Obese subjects revealed kinematic and kinetic data similar to healthy subjects. Conclusion PWS subjects had a gait pattern significantly different from obese patients. Despite that, both groups had a similar BMI. We suggest that PWS gait abnormalities may be related to abnormalities in the development of motor skills in childhood, due to precocious obesity. A tailored rehabilitation program in early childhood of PWS patients could prevent gait pattern changes. PMID:17493259

  11. Gait Speed Predicts Incident Disability: A Pooled Analysis

    PubMed Central

    Patel, Kushang V.; Rosano, Caterina; Rubin, Susan M.; Satterfield, Suzanne; Harris, Tamara; Ensrud, Kristine; Orwoll, Eric; Lee, Christine G.; Chandler, Julie M.; Newman, Anne B.; Cauley, Jane A.; Guralnik, Jack M.; Ferrucci, Luigi; Studenski, Stephanie A.

    2016-01-01

    Background. Functional independence with aging is an important goal for individuals and society. Simple prognostic indicators can inform health promotion and care planning, but evidence is limited by heterogeneity in measures of function. Methods. We performed a pooled analysis of data from seven studies of 27,220 community-dwelling older adults aged 65 or older with baseline gait speed, followed for disability and mortality. Outcomes were incident inability or dependence on another person in bathing or dressing; and difficulty walking ¼ – ½ mile or climbing 10 steps within 3 years. Results. Participants with faster baseline gait had lower rates of incident disability. In subgroups (defined by 0.2 m/s-wide intervals from <0.4 to ≥1.4 m/s) with increasingly greater gait speed, 3-year rates of bathing or dressing dependence trended from 10% to 1% in men, and from 15% to 1% in women, while mobility difficulty trended from 47% to 4% in men and 40% to 6% in women. The age-adjusted relative risk ratio per 0.1 m/s greater speed for bathing or dressing dependence in men was 0.68 (0.57–0.81) and in women: 0.74 (0.66–0.82); for mobility difficulty, men: 0.75 (0.68–0.82), women: 0.73 (0.67–0.80). Results were similar for combined disability and mortality. Effects were largely consistent across subgroups based on age, gender, race, body mass index, prior hospitalization, and selected chronic conditions. In the presence of multiple other risk factors for disability, gait speed significantly increased the area under the receiver operator characteristic curve. Conclusion. In older adults, gait speed predicts 3 year incidence of bathing or dressing dependence, mobility difficulty, and a composite outcome of disability and mortality. PMID:26297942

  12. Assessment of gait in subcortical vascular encephalopathy by computerized analysis: a cross-sectional and longitudinal study.

    PubMed

    Bäzner, H; Oster, M; Daffertshofer, M; Hennerici, M

    2000-11-01

    In subcortical vascular encephalopathy (SVE) gait disturbance is a common and early clinical sign which might be used to monitor disease progression. In the absence of reliable scales and with regard to the equivocal results of highly complex gait imaging devices we assessed the natural course of SVE in a prospective study, using a new straight forward technique to quantify and compare sequential gait studies. We report the results of 300 computerized gait analyses in 119 patients with SVE and 63 age-matched controls. Thirty-nine SVE patients were re-evaluated to monitor the natural course of the disease and to study the correlation of gait disturbances with MRI changes and neuropsychological findings. The system consists of a set of shoes containing 16 load sensors and a measuring-unit reading each sensor at 20-ms intervals. By off-line analysis we graded each recording on a Gait Disorder Score (GDS) with six variables indicating gait steadiness: step frequency, length of gait lines (which represent the movement of the centre of gravity during heel to toe movement), length of single support lines, variability of single and of double support lines, and double support time. In cross-sectional analysis, patients with SVE showed cadence (steps/min) to be reduced at 87.3 +/- 19.5 (96.4 +/- 7.8 in controls, P < 0.05). Length of gait lines was significantly less: 0.70 +/- 0.13 vs. 0.80 +/- 0.05 in controls, with length of single support gait lines reduced at 0.42 +/- 0.14 in SVE (0.58 +/- 0.06 in controls, P < 0.05). Variability of both single support lines (5.69 +/- 1.90%; 4.24 +/- 1.07% in controls, P < 0.05) and double support lines was elevated (3.59 +/- 1.62% vs. 2.54 +/- 0.59%), while duration of double support phases was increased (0.19 +/- 0.10 s vs. 0.13 +/- 0.02 s in controls, P < 0.05). The progressive character of the disease was demonstrated by increasing GDS values in 39 SVE patients with a frontal gait disorder who were re-investigated after a mean interval of 26 months (5.4 +/- 4.5 vs. 8.4 +/- 5.5, P < 0.05). This study shows the value of a new and practicable gait analysis system for the evaluation of gait disorders and it quantifies the deterioration of gait in SVE patients.

  13. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING THE DOUBLE-BUNDLE TECHNIQUE – EVALUATION IN THE BIOMECHANICS LABORATORY

    PubMed Central

    D'Elia, Caio Oliveira; Bitar, Alexandre Carneiro; Castropil, Wagner; Garofo, Antônio Guilherme Padovani; Cantuária, Anita Lopes; Orselli, Maria Isabel Veras; Luques, Isabela Ugo; Duarte, Marcos

    2015-01-01

    Objective: The objective of this study was to describe the methodology of knee rotation analysis using biomechanics laboratory instruments and to present the preliminary results from a comparative study on patients who underwent anterior cruciate ligament (ACL) reconstruction using the double-bundle technique. Methods: The protocol currently used in our laboratory was described. Three-dimensional kinematic analysis was performed and knee rotation amplitude was measured on eight normal patients (control group) and 12 patients who were operated using the double-bundle technique, by means of three tasks in the biomechanics laboratory. Results: No significant differences between operated and non-operated sides were shown in relation to the mean amplitudes of gait, gait with change in direction or gait with change in direction when going down stairs (p > 0.13). Conclusion: The preliminary results did not show any difference in the double-bundle ACL reconstruction technique in relation to the contralateral side and the control group. PMID:27027003

  14. Muscle strength, gait, and balance in 20 patients with hip osteoarthritis followed for 2 years after THA

    PubMed Central

    Dalén, Nils; Berg, Hans E

    2010-01-01

    Background Patients with hip osteoarthritis (OA) have muscular weakness, impaired balance, and limp. Deficits in the different limb muscles and their recovery courses are largely unknown, however. We hypothesized that there is persisting muscular weakness in lower limb muscles and an impaired balance and gait 2 years after THA. Patients and methods 20 elderly patients with unilateral OA were assessed before, and 6 and 24 months after surgery for maximal voluntary isometric strength of hip and knee muscles and by gait analysis, postural stability, and clinical scores (HHS, SF-36, EuroQoL). Results Hip muscles showed a remaining 6% weakness compared to the contralateral healthy limb 2 years after THA. Preoperatively and 6 months postoperatively, that deficit was 18% and 12%, respectively. Knee extensors fully recovered a preoperative 27% deficit after 2 years. Gait analysis demonstrated a shorter single stance phase for the OA limb compared to healthy limb preoperatively, that had already recovered at the 6-month follow-up. Balance of two-foot standing showed improvement in both sagittal and lateral sway after operation. All clinical scores improved. Interpretation Muscle strength data demonstrated a slow but full recovery of muscles acting about the knee, but there was still a deficit in hip muscle strength 2 years after THA. Gait and balance recovered after the operation. To accelerate improvement in muscular strength after THA, postoperative training should probably be more intense and target hip abductors. PMID:20367414

  15. Gait alterations in the UAE population with and without diabetic complications using both traditional and entropy measures.

    PubMed

    Khalaf, Kinda; Al-Angari, Haitham M; Khandoker, Ahsan H; Lee, Sungmun; Almahmeed, Wael; Al Safar, Habiba S; Jelinek, Herbert F

    2017-10-01

    Diabetic foot, one of the most common and debilitating manifestations of type 2 diabetes mellitus (T2DM), is the leading cause of worldwide non-traumatic lower extremity amputations. Diabetics who are at risk of ulceration are currently mainly identified by a thorough clinical examination of the feet, which typically does not show clear symptoms during the early stages of disease progression. In this study, we used a non-linear dynamics tool, gait entropy (GaitEN), in addition to traditional linear gait analysis methods, to investigate gait alterations amongst diabetic patients with combinations of three types of T2DM related complications: retinopathy, diabetic peripheral neuropathy (DPN) and nephropathy. Peak plantar pressure (PPP) was not significantly different in the group with DPN as compared to the control group (diabetics with no complications, CONT) in the forefoot region (DPN: mean±SD: 396±69.4kPa, CONT: 409±68.9kPa), although it was significantly lower in the heel region (DPN: mean±SD: 285±43.1.4kPa, CONT: 295±61.8kPa). On the other hand, gait entropy was significantly lower for the DPN compared to CONT group (DPN: 0.95±0.34, CONT: 1.03±0.28, p<0.05). The significant low entropy was maintained when neuropathy was combined with either retinopathy or nephropathy. For the group with all three complications (ALL-C), the entropy was higher than CONT (ALL-C: 1.07±0.26). This may indicate an intrinsic sensorimotor feedback mechanism for the DPN patients to regulate their gait. However, this feedback gets weaker as patients develop multiple complications. Further analysis with longer walking time and different speeds is needed to verify the entropy results. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Can biomechanical variables predict improvement in crouch gait?

    PubMed Central

    Hicks, Jennifer L.; Delp, Scott L.; Schwartz, Michael H.

    2011-01-01

    Many patients respond positively to treatments for crouch gait, yet surgical outcomes are inconsistent and unpredictable. In this study, we developed a multivariable regression model to determine if biomechanical variables and other subject characteristics measured during a physical exam and gait analysis can predict which subjects with crouch gait will demonstrate improved knee kinematics on a follow-up gait analysis. We formulated the model and tested its performance by retrospectively analyzing 353 limbs of subjects who walked with crouch gait. The regression model was able to predict which subjects would demonstrate ‘improved’ and ‘unimproved’ knee kinematics with over 70% accuracy, and was able to explain approximately 49% of the variance in subjects’ change in knee flexion between gait analyses. We found that improvement in stance phase knee flexion was positively associated with three variables that were drawn from knowledge about the biomechanical contributors to crouch gait: i) adequate hamstrings lengths and velocities, possibly achieved via hamstrings lengthening surgery, ii) normal tibial torsion, possibly achieved via tibial derotation osteotomy, and iii) sufficient muscle strength. PMID:21616666

  17. Reliability and validity of a smartphone-based assessment of gait parameters across walking speed and smartphone locations: Body, bag, belt, hand, and pocket.

    PubMed

    Silsupadol, Patima; Teja, Kunlanan; Lugade, Vipul

    2017-10-01

    The assessment of spatiotemporal gait parameters is a useful clinical indicator of health status. Unfortunately, most assessment tools require controlled laboratory environments which can be expensive and time consuming. As smartphones with embedded sensors are becoming ubiquitous, this technology can provide a cost-effective, easily deployable method for assessing gait. Therefore, the purpose of this study was to assess the reliability and validity of a smartphone-based accelerometer in quantifying spatiotemporal gait parameters when attached to the body or in a bag, belt, hand, and pocket. Thirty-four healthy adults were asked to walk at self-selected comfortable, slow, and fast speeds over a 10-m walkway while carrying a smartphone. Step length, step time, gait velocity, and cadence were computed from smartphone-based accelerometers and validated with GAITRite. Across all walking speeds, smartphone data had excellent reliability (ICC 2,1 ≥0.90) for the body and belt locations, with bag, hand, and pocket locations having good to excellent reliability (ICC 2,1 ≥0.69). Correlations between the smartphone-based and GAITRite-based systems were very high for the body (r=0.89, 0.98, 0.96, and 0.87 for step length, step time, gait velocity, and cadence, respectively). Similarly, Bland-Altman analysis demonstrated that the bias approached zero, particularly in the body, bag, and belt conditions under comfortable and fast speeds. Thus, smartphone-based assessments of gait are most valid when placed on the body, in a bag, or on a belt. The use of a smartphone to assess gait can provide relevant data to clinicians without encumbering the user and allow for data collection in the free-living environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Macrostructural and Microstructural Brain Lesions Relate to Gait Pathology in Children With Cerebral Palsy.

    PubMed

    Meyns, Pieter; Van Gestel, Leen; Leunissen, Inge; De Cock, Paul; Sunaert, Stefan; Feys, Hilde; Duysens, Jacques; Desloovere, Kaat; Ortibus, Els

    2016-10-01

    Background Even though lower-limb motor disorders are core features of spastic cerebral palsy (sCP), the relationship with brain lesions remains unclear. Unraveling the relation between gait pathology, lower-limb function, and brain lesions in sCP is complex for several reasons; wide heterogeneity in brain lesions, ongoing brain maturation, and gait depends on a number of primary motor functions/deficits (eg, muscle strength, spasticity). Objective To use a comprehensive approach combining conventional MRI and diffusion tensor imaging (DTI) in children with sCP above 3 years old to relate quantitative parameters of brain lesions in multiple brain areas to gait performance. Methods A total of 50 children with sCP (25 bilateral, 25 unilateral involvement) were enrolled. The investigated neuroradiological parameters included the following: (1) volumetric measures of the corpus callosum (CC) and lateral ventricles (LVs), and (2) DTI parameters of the corticospinal tract (CST). Gait pathology and primary motor deficits, including muscle strength and spasticity, were evaluated by 3D gait analysis and clinical examination. Results In bilateral sCP (n = 25), volume of the LV and the subparts of the CC connecting frontal, (pre)motor, and sensory areas were most related to lower-limb functioning and gait pathology. DTI measures of the CST revealed additional relations with the primary motor deficits (n = 13). In contrast, in unilateral sCP, volumetric (n = 25) and diffusion measures (n = 14) were only correlated to lower-limb strength. Conclusions These results indicate that the combined influence of multiple brain lesions and their impact on the primary motor deficits might explain a large part of the gait pathology in sCP. © The Author(s) 2016.

  19. Three-dimensional dynamic analysis of knee joint during gait in medial knee osteoarthritis using loading axis of knee.

    PubMed

    Nishino, Katsutoshi; Omori, Go; Koga, Yoshio; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji; Tanaka, Masaei; Arakawa, Masaaki

    2015-07-01

    We recently developed a new method for three-dimensional evaluation of mechanical factors affecting knee joint in order to help identify factors that contribute to the progression of knee osteoarthritis (KOA). This study aimed to verify the clinical validity of our method by evaluating knee joint dynamics during gait. Subjects were 41 individuals (14 normal knees; 8 mild KOAs; 19 severe KOAs). The positions of skin markers attached to the body were captured during gait, and bi-planar X-ray images of the lower extremities were obtained in standing position. The positional relationship between the markers and femorotibial bones was determined from the X-ray images. Combining this relationship with gait capture allowed for the estimation of relative movement between femorotibial bones. We also calculated the point of intersection of loading axis of knee on the tibial proximal surface (LAK point) to analyze knee joint dynamics. Knee flexion range in subjects with severe KOA during gait was significantly smaller than that in those with normal knees (p=0.011), and knee adduction in those with severe KOA was significantly larger than in those with mild KOA (p<0.000). LAK point was locally loaded on the medial compartment of the tibial surface as KOA progressed, with LAK point of subjects with severe KOA rapidly shifting medially during loading response. Local loading and medial shear force were applied to the tibial surface during stance phase as medial KOA progressed. Our findings suggest that our method is useful for the quantitative evaluation of mechanical factors that affect KOA progression. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Gait-force model and inertial measurement unit-based measurements: A new approach for gait analysis and balance monitoring.

    PubMed

    Li, Xinan; Xu, Hongyuan; Cheung, Jeffrey T

    2016-12-01

    This work describes a new approach for gait analysis and balance measurement. It uses an inertial measurement unit (IMU) that can either be embedded inside a dynamically unstable platform for balance measurement or mounted on the lower back of a human participant for gait analysis. The acceleration data along three Cartesian coordinates is analyzed by the gait-force model to extract bio-mechanics information in both the dynamic state as in the gait analyzer and the steady state as in the balance scale. For the gait analyzer, the simple, noninvasive and versatile approach makes it appealing to a broad range of applications in clinical diagnosis, rehabilitation monitoring, athletic training, sport-apparel design, and many other areas. For the balance scale, it provides a portable platform to measure the postural deviation and the balance index under visual or vestibular sensory input conditions. Despite its simple construction and operation, excellent agreement has been demonstrated between its performance and the high-cost commercial balance unit over a wide dynamic range. The portable balance scale is an ideal tool for routine monitoring of balance index, fall-risk assessment, and other balance-related health issues for both clinical and household use.

  1. Gait patterns in hemiplegic patients with equinus foot deformity.

    PubMed

    Manca, M; Ferraresi, G; Cosma, M; Cavazzuti, L; Morelli, M; Benedetti, M G

    2014-01-01

    Equinus deformity of the foot is a common feature of hemiplegia, which impairs the gait pattern of patients. The aim of the present study was to explore the role of ankle-foot deformity in gait impairment. A hierarchical cluster analysis was used to classify the gait patterns of 49 chronic hemiplegic patients with equinus deformity of the foot, based on temporal-distance parameters and joint kinematic measures obtained by an innovative protocol for motion assessment in the sagittal, frontal, and transverse planes, synthesized by parametrical analysis. Cluster analysis identified five subgroups of patients with homogenous levels of dysfunction during gait. Specific joint kinematic abnormalities were found, according to the speed of progression in each cluster. Patients with faster walking were those with less ankle-foot complex impairment or with reduced range of motion of ankle-foot complex, that is with a stiff ankle-foot complex. Slow walking was typical of patients with ankle-foot complex instability (i.e., larger motion in all the planes), severe equinus and hip internal rotation pattern, and patients with hip external rotation pattern. Clustering of gait patterns in these patients is helpful for a better understanding of dysfunction during gait and delivering more targeted treatment.

  2. Gait Characteristic Analysis and Identification Based on the iPhone's Accelerometer and Gyrometer

    PubMed Central

    Sun, Bing; Wang, Yang; Banda, Jacob

    2014-01-01

    Gait identification is a valuable approach to identify humans at a distance. In this paper, gait characteristics are analyzed based on an iPhone's accelerometer and gyrometer, and a new approach is proposed for gait identification. Specifically, gait datasets are collected by the triaxial accelerometer and gyrometer embedded in an iPhone. Then, the datasets are processed to extract gait characteristic parameters which include gait frequency, symmetry coefficient, dynamic range and similarity coefficient of characteristic curves. Finally, a weighted voting scheme dependent upon the gait characteristic parameters is proposed for gait identification. Four experiments are implemented to validate the proposed scheme. The attitude and acceleration solutions are verified by simulation. Then the gait characteristics are analyzed by comparing two sets of actual data, and the performance of the weighted voting identification scheme is verified by 40 datasets of 10 subjects. PMID:25222034

  3. Cross-view gait recognition using joint Bayesian

    NASA Astrophysics Data System (ADS)

    Li, Chao; Sun, Shouqian; Chen, Xiaoyu; Min, Xin

    2017-07-01

    Human gait, as a soft biometric, helps to recognize people by walking. To further improve the recognition performance under cross-view condition, we propose Joint Bayesian to model the view variance. We evaluated our prosed method with the largest population (OULP) dataset which makes our result reliable in a statically way. As a result, we confirmed our proposed method significantly outperformed state-of-the-art approaches for both identification and verification tasks. Finally, sensitivity analysis on the number of training subjects was conducted, we find Joint Bayesian could achieve competitive results even with a small subset of training subjects (100 subjects). For further comparison, experimental results, learning models, and test codes are available.

  4. A sensitivity analysis method for the body segment inertial parameters based on ground reaction and joint moment regressor matrices.

    PubMed

    Futamure, Sumire; Bonnet, Vincent; Dumas, Raphael; Venture, Gentiane

    2017-11-07

    This paper presents a method allowing a simple and efficient sensitivity analysis of dynamics parameters of complex whole-body human model. The proposed method is based on the ground reaction and joint moment regressor matrices, developed initially in robotics system identification theory, and involved in the equations of motion of the human body. The regressor matrices are linear relatively to the segment inertial parameters allowing us to use simple sensitivity analysis methods. The sensitivity analysis method was applied over gait dynamics and kinematics data of nine subjects and with a 15 segments 3D model of the locomotor apparatus. According to the proposed sensitivity indices, 76 segments inertial parameters out the 150 of the mechanical model were considered as not influent for gait. The main findings were that the segment masses were influent and that, at the exception of the trunk, moment of inertia were not influent for the computation of the ground reaction forces and moments and the joint moments. The same method also shows numerically that at least 90% of the lower-limb joint moments during the stance phase can be estimated only from a force-plate and kinematics data without knowing any of the segment inertial parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Robot-assisted gait training versus treadmill training in patients with Parkinson's disease: a kinematic evaluation with gait profile score.

    PubMed

    Galli, M; Cimolin, V; De Pandis, M F; Le Pera, D; Sova, I; Albertini, G; Stocchi, F; Franceschini, M

    2016-01-01

    The purpose of this study was to quantitatively compare the effects, on walking performance, of end-effector robotic rehabilitation locomotor training versus intensive training with a treadmill in Parkinson's disease (PD). Fifty patients with PD were randomly divided into two groups: 25 were assigned to the robot-assisted therapy group (RG) and 25 to the intensive treadmill therapy group (IG). They were evaluated with clinical examination and 3D quantitative gait analysis [gait profile score (GPS) and its constituent gait variable scores (GVSs) were calculated from gait analysis data] at the beginning (T0) and at the end (T1) of the treatment. In the RG no differences were found in the GPS, but there were significant improvements in some GVSs (Pelvic Obl and Hip Ab-Add). The IG showed no statistically significant changes in either GPS or GVSs. The end-effector robotic rehabilitation locomotor training improved gait kinematics and seems to be effective for rehabilitation in patients with mild PD.

  6. Quantitative Balance and Gait Measurement in Patients with Frontotemporal Dementia and Alzheimer Diseases: A Pilot Study.

    PubMed

    Velayutham, Selva Ganapathy; Chandra, Sadanandavalli Retnaswami; Bharath, Srikala; Shankar, Ravi Girikamatha

    2017-01-01

    Alzhiemers disease and Frontotemporal dementia are common neurodegenerative dementias with a wide prevalence. Falls are a common cause of morbidity in these patients. Identifying subclinical involvement of these parameters might serve as a tool in differential analysis of these distinct parameters involved in these conditions and also help in planning preventive strategies to prevent falls. Eight patients in age and gender matched patients in each group were compared with normal controls. Standardizes methods of gait and balance aseesment were done in all persons. Results revealed subclinical involvement of gait and balancesin all groups specially during divided attention. The parameters were significantly more affected in patients. Patients with AD and FTD had involement of over all ambulation index balance more affected in AD patients FTD patients showed step cycle, stride length abnormalities. There is balance and gait involvement in normal ageing as well as patients with AD and FTD. The pattern of involvement in AD correlates with WHERE pathway involvement and FTD with frontal subcortical circuits involvement. Identification the differential patterns of involvement in subclinical stage might help to differentiate normal ageing and the different types of cortical dementias. This could serve as an additional biomarker and also assist in initiating appropriate training methods to prevent future falls.

  7. Neurotomy of the rectus femoris nerve: Short-term effectiveness for spastic stiff knee gait: Clinical assessment and quantitative gait analysis.

    PubMed

    Gross, R; Robertson, J; Leboeuf, F; Hamel, O; Brochard, S; Perrouin-Verbe, B

    2017-02-01

    Stiff knee gait is a troublesome gait disturbance related to spastic paresis, frequently associated with overactivity of the rectus femoris muscle in the swing phase of gait. The aim of this study was to assess the short-term effects of rectus femoris neurotomy for the treatment of spastic stiff-knee gait in patients with hemiparesis. An Intervention study (before-after trial) with an observational design was carried out in a university hospital. Seven ambulatory patients with hemiparesis of spinal or cerebral origin and spastic stiff-knee gait, which had previously been improved by botulinum toxin injections, were proposed a selective neurotomy of the rectus femoris muscle. A functional evaluation (Functional Ambulation Classification and maximal walking distance), clinical evaluation (spasticity - Ashworth scale and Duncan-Ely test, muscle strength - Medical Research Council scale), and quantitative gait analysis (spatiotemporal parameters, stiff knee gait-related kinematic and kinetic parameters, and dynamic electromyography of rectus femoris) were performed as outcome measures, before and 3 months after rectus femoris neurotomy. Compared with preoperative values, there was a significant increase in maximal walking distance, gait speed, and stride length at 3 months. All kinematic parameters improved, and the average early swing phase knee extension moment decreased. The duration of the rectus femoris burst decreased post-op. This study is the first to show that rectus femoris neurotomy helps to normalise muscle activity during gait, and results in improvements in kinetic, kinematic, and functional parameters in patients with spastic stiff knee gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Understanding adaptive gait in lower-limb amputees: insights from multivariate analyses

    PubMed Central

    2013-01-01

    Background In this paper we use multivariate statistical techniques to gain insights into how adaptive gait involving obstacle crossing is regulated in lower-limb amputees compared to able-bodied controls, with the aim of identifying underlying characteristics that differ between the two groups and consequently highlighting gait deficits in the amputees. Methods Eight unilateral trans-tibial amputees and twelve able-bodied controls completed adaptive gait trials involving negotiating various height obstacles; with amputees leading with their prosthetic limb. Spatiotemporal variables that are regularly used to quantify how gait is adapted when crossing obstacles were determined and subsequently analysed using multivariate statistical techniques. Results and discussion There were fundamental differences in the adaptive gait between the two groups. Compared to controls, amputees had a reduced approach velocity, reduced foot placement distance before and after the obstacle and reduced foot clearance over it, and reduced lead-limb knee flexion during the step following crossing. Logistic regression analysis highlighted the variables that best distinguished between the gait of the two groups and multiple regression analysis (with approach velocity as a controlling factor) helped identify what gait adaptations were driving the differences seen in these variables. Getting closer to the obstacle before crossing it appeared to be a strategy to ensure the heel of the lead-limb foot passed over the obstacle prior to the foot being lowered to the ground. Despite adopting such a heel clearance strategy, the lead-foot was positioned closer to the obstacle following crossing, which was likely a result of a desire to attain a limb/foot angle and orientation at instant of landing that minimised loads on the residuum (as evidenced by the reduced lead-limb knee flexion during the step following crossing). These changes in foot placement meant the foot was in a different part of swing at point of crossing and this explains why foot clearance was considerably reduced in amputees. Conclusions These results highlight that trans-tibial amputees use quite different gait adaptations to cross obstacles compared with controls (at least when leading with their prosthetic limb), indicating they are governed by different constraints; seemingly related to how they land on/load their prosthesis after crossing the obstacle. PMID:23958032

  9. Vision-based gait impairment analysis for aided diagnosis.

    PubMed

    Ortells, Javier; Herrero-Ezquerro, María Trinidad; Mollineda, Ramón A

    2018-02-12

    Gait is a firsthand reflection of health condition. This belief has inspired recent research efforts to automate the analysis of pathological gait, in order to assist physicians in decision-making. However, most of these efforts rely on gait descriptions which are difficult to understand by humans, or on sensing technologies hardly available in ambulatory services. This paper proposes a number of semantic and normalized gait features computed from a single video acquired by a low-cost sensor. Far from being conventional spatio-temporal descriptors, features are aimed at quantifying gait impairment, such as gait asymmetry from several perspectives or falling risk. They were designed to be invariant to frame rate and image size, allowing cross-platform comparisons. Experiments were formulated in terms of two databases. A well-known general-purpose gait dataset is used to establish normal references for features, while a new database, introduced in this work, provides samples under eight different walking styles: one normal and seven impaired patterns. A number of statistical studies were carried out to prove the sensitivity of features at measuring the expected pathologies, providing enough evidence about their accuracy. Graphical Abstract Graphical abstract reflecting main contributions of the manuscript: at the top, a robust, semantic and easy-to-interpret feature set to describe impaired gait patterns; at the bottom, a new dataset consisting of video-recordings of a number of volunteers simulating different patterns of pathological gait, where features were statistically assessed.

  10. Estimation of Temporal Gait Parameters Using a Human Body Electrostatic Sensing-Based Method.

    PubMed

    Li, Mengxuan; Li, Pengfei; Tian, Shanshan; Tang, Kai; Chen, Xi

    2018-05-28

    Accurate estimation of gait parameters is essential for obtaining quantitative information on motor deficits in Parkinson's disease and other neurodegenerative diseases, which helps determine disease progression and therapeutic interventions. Due to the demand for high accuracy, unobtrusive measurement methods such as optical motion capture systems, foot pressure plates, and other systems have been commonly used in clinical environments. However, the high cost of existing lab-based methods greatly hinders their wider usage, especially in developing countries. In this study, we present a low-cost, noncontact, and an accurate temporal gait parameters estimation method by sensing and analyzing the electrostatic field generated from human foot stepping. The proposed method achieved an average 97% accuracy on gait phase detection and was further validated by comparison to the foot pressure system in 10 healthy subjects. Two results were compared using the Pearson coefficient r and obtained an excellent consistency ( r = 0.99, p < 0.05). The repeatability of the purposed method was calculated between days by intraclass correlation coefficients (ICC), and showed good test-retest reliability (ICC = 0.87, p < 0.01). The proposed method could be an affordable and accurate tool to measure temporal gait parameters in hospital laboratories and in patients' home environments.

  11. Estimates of circulation and gait change based on a three-dimensional kinematic analysis of flight in cockatiels (Nymphicus hollandicus) and ringed turtle-doves (Streptopelia risoria).

    PubMed

    Hedrick, Tyson L; Tobalske, Bret W; Biewener, Andrew A

    2002-05-01

    Birds and bats are known to employ two different gaits in flapping flight, a vortex-ring gait in slow flight and a continuous-vortex gait in fast flight. We studied the use of these gaits over a wide range of speeds (1-17 ms(-1)) and transitions between gaits in cockatiels (Nymphicus hollandicus) and ringed turtle-doves (Streptopelia risoria) trained to fly in a recently built, variable-speed wind tunnel. Gait use was investigated via a combination of three-dimensional kinematics and quasi-steady aerodynamic modeling of bound circulation on the distal and proximal portions of the wing. Estimates of lift from our circulation model were sufficient to support body weight at all but the slowest speeds (1 and 3 ms(-1)). From comparisons of aerodynamic impulse derived from our circulation analysis with the impulse estimated from whole-body acceleration, it appeared that our quasi-steady aerodynamic analysis was most accurate at intermediate speeds (5-11 ms(-1)). Despite differences in wing shape and wing loading, both species shifted from a vortex-ring to a continuous-vortex gait at 7 ms(-1). We found that the shift from a vortex-ring to a continuous-vortex gait (i) was associated with a phase delay in the peak angle of attack of the proximal wing section from downstroke into upstroke and (ii) depended on sufficient forward velocity to provide airflow over the wing during the upstroke similar to that during the downstroke. Our kinematic estimates indicated significant variation in the magnitude of circulation over the course the wingbeat cycle when either species used a continuous-vortex gait. This variation was great enough to suggest that both species shifted to a ladder-wake gait as they approached the maximum flight speed (cockatiels 15 ms(-1), doves 17 ms(-1)) that they would sustain in the wind tunnel. This shift in flight gait appeared to reflect the need to minimize drag and produce forward thrust in order to fly at high speed. The ladder-wake gait was also employed in forward and vertical acceleration at medium and fast flight speeds.

  12. [Update rehabilitation therapy for Parkinson disease].

    PubMed

    Hayashi, Akito

    2013-01-01

    Rehabilitation is essential for treatment of Parkinson's disease. New rehabilitation therapy is updated, in addition to evidence shown with "Parkinson's disease treatment guidelines 2011". Furthermore, a portable gait rhythmogram (acceleration sensor) is presented (not publication). Parkinsonian gait was significantly slow and the steps were small, but the cadence was not different compared as that of normal control. The strength of parkinsonian gait was apparently week compared as normal control. We also could examine consecutive changes of gait rhythm and detect freezing gait in patients. In this study, we could extract the characteristic of the parkinsonian gait and evaluate especially freeing events more objectively. This method may bring us to evaluate severity of parkinsonian gait not only in a consulting room but also daily profile even not to see directly, using the portable gait rhythmogram.

  13. Effect of Rhythmic Auditory Stimulation on Hemiplegic Gait Patterns

    PubMed Central

    Shin, Yoon-Kyum; Chong, Hyun Ju

    2015-01-01

    Purpose The purpose of our study was to investigate the effect of gait training with rhythmic auditory stimulation (RAS) on both kinematic and temporospatial gait patterns in patients with hemiplegia. Materials and Methods Eighteen hemiplegic patients diagnosed with either cerebral palsy or stroke participated in this study. All participants underwent the 4-week gait training with RAS. The treatment was performed for 30 minutes per each session, three sessions per week. RAS was provided with rhythmic beats using a chord progression on a keyboard. Kinematic and temporospatial data were collected and analyzed using a three-dimensional motion analysis system. Results Gait training with RAS significantly improved both proximal and distal joint kinematic patterns in hip adduction, knee flexion, and ankle plantar flexion, enhancing the gait deviation index (GDI) as well as ameliorating temporal asymmetry of the stance and swing phases in patients with hemiplegia. Stroke patients with previous walking experience demonstrated significant kinematic improvement in knee flexion in mid-swing and ankle dorsiflexion in terminal stance. Among stroke patients, subacute patients showed a significantly increased GDI score compared with chronic patients. In addition, household ambulators showed a significant effect on reducing anterior tilt of the pelvis with an enhanced GDI score, while community ambulators significantly increased knee flexion in mid-swing phase and ankle dorsiflexion in terminal stance phase. Conclusion Gait training with RAS has beneficial effects on both kinematic and temporospatial patterns in patients with hemiplegia, providing not only clinical implications of locomotor rehabilitation with goal-oriented external feedback using RAS but also differential effects according to ambulatory function. PMID:26446657

  14. The Effect of Body Weight Support Treadmill Training on Gait Recovery, Proximal Lower Limb Motor Pattern, and Balance in Patients with Subacute Stroke

    PubMed Central

    Lo, Wai Leung; Lin, Qiang; Xiao, Xiang; Raghavan, Preeti; Huang, Dong-Feng

    2015-01-01

    Objective. Gait performance is an indicator of mobility impairment after stroke. This study evaluated changes in balance, lower extremity motor function, and spatiotemporal gait parameters after receiving body weight supported treadmill training (BWSTT) and conventional overground walking training (CT) in patients with subacute stroke using 3D motion analysis. Setting. Inpatient department of rehabilitation medicine at a university-affiliated hospital. Participants. 24 subjects with unilateral hemiplegia in the subacute stage were randomized to the BWSTT (n = 12) and CT (n = 12) groups. Parameters were compared between the two groups. Data from twelve age matched healthy subjects were recorded as reference. Interventions. Patients received gait training with BWSTT or CT for an average of 30 minutes/day, 5 days/week, for 3 weeks. Main Outcome Measures. Balance was measured by the Brunel balance assessment. Lower extremity motor function was evaluated by the Fugl-Meyer assessment scale. Kinematic data were collected and analyzed using a gait capture system before and after the interventions. Results. Both groups improved on balance and lower extremity motor function measures (P < 0.05), with no significant difference between the two groups after intervention. However, kinematic data were significantly improved (P < 0.05) after BWSTT but not after CT. Maximum hip extension and flexion angles were significantly improved (P < 0.05) for the BWSTT group during the stance and swing phases compared to baseline. Conclusion. In subacute patients with stroke, BWSTT can lead to improved gait quality when compared with conventional gait training. Both methods can improve balance and motor function. PMID:26649295

  15. The Effect of Body Weight Support Treadmill Training on Gait Recovery, Proximal Lower Limb Motor Pattern, and Balance in Patients with Subacute Stroke.

    PubMed

    Mao, Yu-Rong; Lo, Wai Leung; Lin, Qiang; Li, Le; Xiao, Xiang; Raghavan, Preeti; Huang, Dong-Feng

    2015-01-01

    Gait performance is an indicator of mobility impairment after stroke. This study evaluated changes in balance, lower extremity motor function, and spatiotemporal gait parameters after receiving body weight supported treadmill training (BWSTT) and conventional overground walking training (CT) in patients with subacute stroke using 3D motion analysis. Inpatient department of rehabilitation medicine at a university-affiliated hospital. 24 subjects with unilateral hemiplegia in the subacute stage were randomized to the BWSTT (n = 12) and CT (n = 12) groups. Parameters were compared between the two groups. Data from twelve age matched healthy subjects were recorded as reference. Patients received gait training with BWSTT or CT for an average of 30 minutes/day, 5 days/week, for 3 weeks. Balance was measured by the Brunel balance assessment. Lower extremity motor function was evaluated by the Fugl-Meyer assessment scale. Kinematic data were collected and analyzed using a gait capture system before and after the interventions. Both groups improved on balance and lower extremity motor function measures (P < 0.05), with no significant difference between the two groups after intervention. However, kinematic data were significantly improved (P < 0.05) after BWSTT but not after CT. Maximum hip extension and flexion angles were significantly improved (P < 0.05) for the BWSTT group during the stance and swing phases compared to baseline. In subacute patients with stroke, BWSTT can lead to improved gait quality when compared with conventional gait training. Both methods can improve balance and motor function.

  16. Screw-Home Movement of the Tibiofemoral Joint during Normal Gait: Three-Dimensional Analysis

    PubMed Central

    Kim, Ha Yong; Yang, Dae Suk; Jeung, Sang Wook; Choi, Han Gyeol; Choy, Won Sik

    2015-01-01

    Background The purpose of this study was to evaluate the screw-home movement at the tibiofemoral joint during normal gait by utilizing the 3-dimensional motion capture technique. Methods Fifteen young males and fifteen young females (total 60 knee joints) who had no history of musculoskeletal disease or a particular gait problem were included in this study. Two more markers were attached to the subject in addition to the Helen-Hayes marker set. Thus, two virtual planes, femoral coronal plane (Pf) and tibial coronal plane (Pt), were created by Skeletal Builder software. This study measured the 3-dimensional knee joint movement in the sagittal, coronal, and transverse planes of these two virtual planes (Pf and Pt) during normal gait. Results With respect to kinematics and kinetics, both males and females showed normal adult gait patterns, and the mean difference in the temporal gait parameters was not statistically significant (p > 0.05). In the transverse plane, the screw-home movement occurred as expected during the pre-swing phase and the late-swing phase at an angle of about 17°. However, the tibia rotated externally with respect to the femur, rather than internally, while the knee joint started to flex during the loading response (paradoxical screw-home movement), and the angle was 6°. Conclusions Paradoxical screw-home movement may be an important mechanism that provides stability to the knee joint during the remaining stance phase. Obtaining the kinematic values of the knee joint during gait can be useful in diagnosing and treating the pathological knee joints. PMID:26330951

  17. No effects of functional exercise therapy on walking biomechanics in patients with knee osteoarthritis: exploratory outcome analyses from a randomised trial

    PubMed Central

    Bartholdy, Cecilie; Schjoedt-Jorgensen, Tanja; Bliddal, Henning

    2016-01-01

    Aim To assess the effects of a functional and individualised exercise programme on gait biomechanics during walking in people with knee OA. Methods Sixty participants were randomised to 12 weeks of facility-based functional and individualised neuromuscular exercise therapy (ET), 3 sessions per week supervised by trained physical therapists, or a no attention control group (CG). Three-dimensional gait analyses were used, from which a comprehensive list of conventional gait variables were extracted (totally 52 kinematic, kinetic and spatiotemporal variables). According to the protocol, the analyses were based on the ‘Per-Protocol’ population (defined as participants following the protocol with complete and valid gait analyses). Analysis of covariance adjusting for the level at baseline was used to determine differences between groups (95% CIs) in the changes from baseline at follow-up. Results The per-protocol population included 46 participants (24 ET/22 CG). There were no group differences in the analysed gait variables, except for a significant group difference in the second peak knee flexor moment and second peak vertical ground reaction force. Conclusion While plausible we have limited confidence in the findings due to multiple statistical tests and lack of biomechanical logics. Therefore we conclude that a 12-week supervised individualised neuromuscular exercise programme has no effects on gait biomechanics. Future studies should focus on exercise programmes specifically designed to alter gait patterns, or include other measures of mobility, such as walking on stairs or inclined surfaces. Trial registration number ClinicalTrials.gov: NCT01545258. PMID:28879038

  18. Behavioral and Neural Correlates of Imagined Walking and Walking-While-Talking in the Elderly

    PubMed Central

    Blumen, Helena M.; Holtzer, Roee; Brown, Lucy L.; Gazes, Yunglin; Verghese, Joe

    2014-01-01

    Cognition is important for locomotion and gait decline increases the risk for morbidity, mortality, cognitive decline, and dementia. Yet, the neural correlates of gait are not well established, because most neuroimaging methods cannot image the brain during locomotion. Imagined gait protocols overcome this limitation. This study examined the behavioral and neural correlates of a new imagined gait protocol that involved imagined walking (iW), imagined talking (iT), and imagined walking-while-talking (iWWT). In Experiment 1, 82 cognitively-healthy older adults (M = 80.45) walked (W), iW, walked while talking (WWT) and iWWT. Real and imagined walking task times were strongly correlated, particularly real and imagined dual-task times (WWT and iWWT). In Experiment 2, 33 cognitively-healthy older adults (M = 73.03) iW, iT, and iWWT during functional Magnetic Resonance Imaging. A multivariate Ordinal Trend (OrT) Covariance analysis identified a pattern of brain regions that: 1) varied as a function of imagery task difficulty (iW, iT and iWWT), 2) involved cerebellar, precuneus, supplementary motor and other prefrontal regions, and 3) were associated with kinesthetic imagery ratings and behavioral performance during actual WWT. This is the first study to compare the behavioral and neural correlates of imagined gait in single and dual-task situations, an issue that is particularly relevant to elderly populations. These initial findings encourage further research and development of this imagined gait protocol as a tool for improving gait and cognition among the elderly. PMID:24522972

  19. The effect of frame rate on the ability of experienced gait analysts to identify characteristics of gait from closed circuit television footage.

    PubMed

    Birch, Ivan; Vernon, Wesley; Burrow, Gordon; Walker, Jeremy

    2014-03-01

    Forensic gait analysis is increasingly being used as part of criminal investigations. A major issue is the quality of the closed circuit television (CCTV) footage used, particularly the frame rate which can vary from 25 frames per second to one frame every 4s. To date, no study has investigated the effect of frame rate on forensic gait analysis. A single subject was fitted with an ankle foot orthosis and recorded walking at 25 frames per second. 3D motion data were also collected, providing an absolute assessment of the gait characteristics. The CCTV footage was then edited to produce a set of eight additional pieces of footage, at various frame rates. Practitioners with knowledge of forensic gait analysis were recruited and instructed to record their observations regarding the characteristics of the subject's gait from the footage. They were sequentially sent web links to the nine pieces of footage, lowest frame rate first, and a simple observation recording form, over a period of 8 months. A sample-based Pearson product-moment correlation analysis of the results demonstrated a significant positive relationship between frame rate and scores (r=0.868, p=0.002). The results of this study show that frame rate affects the ability of experienced practitioners to identify characteristics of gait captured on CCTV footage. Every effort should therefore be made to ensure that CCTV footage likely to be used in criminal proceedings is captured at as high a frame rate as possible. © 2013.

  20. GaitaBase: Web-based repository system for gait analysis.

    PubMed

    Tirosh, Oren; Baker, Richard; McGinley, Jenny

    2010-02-01

    The need to share gait analysis data to improve clinical decision support has been recognised since the early 1990s. GaitaBase has been established to provide a web-accessible repository system of gait analysis data to improve the sharing of data across local and international clinical and research community. It is used by several clinical and research groups across the world providing cross-group access permissions to retrieve and analyse the data. The system is useful for bench-marking and quality assurance, clinical consultation, and collaborative research. It has the capacity to increase the population sample size and improve the quality of 'normative' gait data. In addition the accumulated stored data may facilitate clinicians in comparing their own gait data with others, and give a valuable insight into how effective specific interventions have been for others. 2009 Elsevier Ltd. All rights reserved.

  1. The development and validity of the Salford Gait Tool: an observation-based clinical gait assessment tool.

    PubMed

    Toro, Brigitte; Nester, Christopher J; Farren, Pauline C

    2007-03-01

    To develop the construct, content, and criterion validity of the Salford Gait Tool (SF-GT) and to evaluate agreement between gait observations using the SF-GT and kinematic gait data. Tool development and comparative evaluation. University in the United Kingdom. For designing construct and content validity, convenience samples of 10 children with hemiplegic, diplegic, and quadriplegic cerebral palsy (CP) and 152 physical therapy students and 4 physical therapists were recruited. For developing criterion validity, kinematic gait data of 13 gait clusters containing 56 children with hemiplegic, diplegic, and quadriplegic CP and 11 neurologically intact children was used. For clinical evaluation, a convenience sample of 23 pediatric physical therapists participated. We developed a sagittal plane observational gait assessment tool through a series of design, test, and redesign iterations. The tool's grading system was calibrated using kinematic gait data of 13 gait clusters and was evaluated by comparing the agreement of gait observations using the SF-GT with kinematic gait data. Criterion standard kinematic gait data. There was 58% mean agreement based on grading categories and 80% mean agreement based on degree estimations evaluated with the least significant difference method. The new SF-GT has good concurrent criterion validity.

  2. Analysis of foot load during ballet dancers' gait.

    PubMed

    Prochazkova, Marketa; Tepla, Lucie; Svoboda, Zdenek; Janura, Miroslav; Cieslarová, Miloslava

    2014-01-01

    Ballet is an art that puts extreme demands on the dancer's musculoskeletal system and therefore significantly affects motor behavior of the dancers. The aim of our research was to compare plantar pressure distribution during stance phase of gait between a group of professional ballet dancers and non-dancers. Thirteen professional dancers (5 men, 8 women; mean age of 24.1 ± 3.8 years) and 13 nondancers (5 men, 8 women; mean age of 26.1 ± 5.3 years) participated in this study. Foot pressure analysis during gait was collected using a 2 m pressure plate. The participants were instructed to walk across the platform at a self-selected pace barefoot. Three gait cycles were necessary for the data analysis. The results revealed higher (p < 0.05) pressure peaks in medial edge of forefoot during gait for dancers in comparison with nondancers. Furthermore, differences in total foot loading and foot loading duration of rearfoot was higher (p < 0.05) in dancers as well. We can attribute these differences to long-term and intensive dancing exercises that can change the dancer's gait stereotype.

  3. Reliability and validity of gait analysis by android-based smartphone.

    PubMed

    Nishiguchi, Shu; Yamada, Minoru; Nagai, Koutatsu; Mori, Shuhei; Kajiwara, Yuu; Sonoda, Takuya; Yoshimura, Kazuya; Yoshitomi, Hiroyuki; Ito, Hiromu; Okamoto, Kazuya; Ito, Tatsuaki; Muto, Shinyo; Ishihara, Tatsuya; Aoyama, Tomoki

    2012-05-01

    Smartphones are very common devices in daily life that have a built-in tri-axial accelerometer. Similar to previously developed accelerometers, smartphones can be used to assess gait patterns. However, few gait analyses have been performed using smartphones, and their reliability and validity have not been evaluated yet. The purpose of this study was to evaluate the reliability and validity of a smartphone accelerometer. Thirty healthy young adults participated in this study. They walked 20 m at their preferred speeds, and their trunk accelerations were measured using a smartphone and a tri-axial accelerometer that was secured over the L3 spinous process. We developed a gait analysis application and installed it in the smartphone to measure the acceleration. After signal processing, we calculated the gait parameters of each measurement terminal: peak frequency (PF), root mean square (RMS), autocorrelation peak (AC), and coefficient of variance (CV) of the acceleration peak intervals. Remarkable consistency was observed in the test-retest reliability of all the gait parameter results obtained by the smartphone (p<0.001). All the gait parameter results obtained by the smartphone showed statistically significant and considerable correlations with the same parameter results obtained by the tri-axial accelerometer (PF r=0.99, RMS r=0.89, AC r=0.85, CV r=0.82; p<0.01). Our study indicates that the smartphone with gait analysis application used in this study has the capacity to quantify gait parameters with a degree of accuracy that is comparable to that of the tri-axial accelerometer.

  4. Does a single gait training session performed either overground or on a treadmill induce specific short-term effects on gait parameters in patients with hemiparesis? A randomized controlled study.

    PubMed

    Bonnyaud, Céline; Pradon, Didier; Zory, Raphael; Bensmail, Djamel; Vuillerme, Nicolas; Roche, Nicolas

    2013-01-01

    Gait training for patients with hemiparesis is carried out independently overground or on a treadmill. Several studies have shown differences in hemiparetic gait parameters during overground versus treadmill walking. However, few studies have compared the effects of these 2 gait training conditions on gait parameters, and no study has compared the short-term effects of these techniques on all biomechanical gait parameters. To determine whether a gait training session performed overground or on a treadmill induces specific short-term effects on biomechanical gait parameters in patients with hemiparesis. Twenty-six subjects with hemiparesis were randomly assigned to a single session of either overground or treadmill gait training. The short-term effects on spatiotemporal, kinematic, and kinetic gait parameters were assessed using gait analysis before and immediately after the training and after a 20-minute rest. Speed, cadence, percentage of single support phase, peak knee extension, peak propulsion, and braking on the paretic side were significantly increased after the gait training session. However, there were no specific changes dependent on the type of gait training performed (overground or on a treadmill). A gait training session performed by subjects with hemiparesis overground or on a treadmill did not induce specific short-term effects on biomechanical gait parameters. The increase in gait velocity that followed a gait training session seemed to reflect specific modifications of the paretic lower limb and adaptation of the nonparetic lower limb.

  5. Learning Efficient Spatial-Temporal Gait Features with Deep Learning for Human Identification.

    PubMed

    Liu, Wu; Zhang, Cheng; Ma, Huadong; Li, Shuangqun

    2018-02-06

    The integration of the latest breakthroughs in bioinformatics technology from one side and artificial intelligence from another side, enables remarkable advances in the fields of intelligent security guard computational biology, healthcare, and so on. Among them, biometrics based automatic human identification is one of the most fundamental and significant research topic. Human gait, which is a biometric features with the unique capability, has gained significant attentions as the remarkable characteristics of remote accessed, robust and security in the biometrics based human identification. However, the existed methods cannot well handle the indistinctive inter-class differences and large intra-class variations of human gait in real-world situation. In this paper, we have developed an efficient spatial-temporal gait features with deep learning for human identification. First of all, we proposed a gait energy image (GEI) based Siamese neural network to automatically extract robust and discriminative spatial gait features for human identification. Furthermore, we exploit the deep 3-dimensional convolutional networks to learn the human gait convolutional 3D (C3D) as the temporal gait features. Finally, the GEI and C3D gait features are embedded into the null space by the Null Foley-Sammon Transform (NFST). In the new space, the spatial-temporal features are sufficiently combined with distance metric learning to drive the similarity metric to be small for pairs of gait from the same person, and large for pairs from different persons. Consequently, the experiments on the world's largest gait database show our framework impressively outperforms state-of-the-art methods.

  6. Gait impairment precedes clinical symptoms in spinocerebellar ataxia type 6.

    PubMed

    Rochester, Lynn; Galna, Brook; Lord, Sue; Mhiripiri, Dadirayi; Eglon, Gail; Chinnery, Patrick F

    2014-02-01

    Spinocerebellar ataxia type 6 (SCA6) is an inherited ataxia with no established treatment. Gait ataxia is a prominent feature causing substantial disability. Understanding the evolution of the gait disturbance is a key step in developing treatment strategies. We studied 9 gait variables in 24 SCA6 (6 presymptomatic; 18 symptomatic) and 24 controls and correlated gait with clinical severity (presymptomatic and symptomatic). Discrete gait characteristics precede symptoms in SCA6 with significantly increased variability of step width and step time, whereas a more global gait deficit was evident in symptomatic individuals. Gait characteristics discriminated between presymptomatic and symptomatic individuals and were selectively associated with disease severity. This is the largest study to include a detailed characterization of gait in SCA6, including presymptomatic subjects, allowing changes across the disease spectrum to be compared. Selective gait disturbance is already present in SCA6 before clinical symptoms appear and gait characteristics are also sensitive to disease progression. Early gait disturbance likely reflects primary pathology distinct from secondary changes. These findings open the opportunity for early evaluation and sensitive measures of therapeutic efficacy using instrumented gait analysis which may have broader relevance for all degenerative ataxias. © 2013 Movement Disorder Society.

  7. Plasticity of spinal centers in spinal cord injury patients: new concepts for gait evaluation and training.

    PubMed

    Scivoletto, Giorgio; Ivanenko, Yuri; Morganti, Barbara; Grasso, Renato; Zago, Mirka; Lacquaniti, Francesco; Ditunno, John; Molinari, Marco

    2007-01-01

    Recent data on spinal cord plasticity after spinal cord injury (SCI) were reviewed to analyze the influence of training on the neurophysiological organization of locomotor spinal circuits in SCI patients. In particular, the authors studied the relationship between central pattern generators (CPGs) and motor neuron pool activation during gait. An analysis of the relations between locomotor recovery and compensatory mechanisms focuses on the hierarchical organization of gait parameters and allows characterizing kinematic parameters that are highly stable during different gait conditions and in recovered gait after SCI. The importance of training characteristics and the use of robotic/automated devices in gait recovery is analyzed and discussed. The role of CPG in defining kinematic gait parameters is summarized, and spatio-temporal maps of EMG activity during gait are used to clarify the role of CPG plasticity in sustaining gait recovery.

  8. Does acupuncture ameliorate motor impairment after stroke? An assessment using the CatWalk gait system.

    PubMed

    Cao, Yan; Sun, Ning; Yang, Jing-Wen; Zheng, Yang; Zhu, Wen; Zhang, Zhen-Hua; Wang, Xue-Rui; Shi, Guang-Xia; Liu, Cun-Zhi

    2017-07-01

    The effect of acupuncture on gait deficits after stroke is uncertain. This animal study was designed to determine whether acupuncture improves gait impairment following experimentally induced ischemic stroke. Ischemic stroke was induced by permanent middle cerebral artery occlusion (MCAO) in rats. After 7 days' of acupuncture treatment, assessment of gait changes using the CatWalk automated gait analysis system was performed. Comparison of the CatWalk gait parameters among the groups showed that gait function was impaired after ischemic stroke and acupuncture treatment was effective in improving a variety of gait parameters including intensity, stance and swing time, swing speed and stride length at postoperative day 8. This study demonstrates a beneficial effect of acupuncture on gait impairment in rats following ischemic stroke. Further studies aimed to investigate the effects of acupuncture at different stages during stroke using the CatWalk system are required. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Kinematic and dynamic gait compensations in a rat model of lumbar radiculopathy and the effects of tumor necrosis factor-alpha antagonism

    PubMed Central

    2011-01-01

    Introduction Tumor necrosis factor-α (TNFα) has received significant attention as a mediator of lumbar radiculopathy, with interest in TNF antagonism to treat radiculopathy. Prior studies have demonstrated that TNF antagonists can attenuate heightened nociception resulting from lumbar radiculopathy in the preclinical model. Less is known about the potential impact of TNF antagonism on gait compensations, despite being of clinical relevance. In this study, we expand on previous descriptions of gait compensations resulting from lumbar radiculopathy in the rat and describe the ability of local TNF antagonism to prevent the development of gait compensations, altered weight bearing, and heightened nociception. Methods Eighteen male Sprague-Dawley rats were investigated for mechanical sensitivity, weight-bearing, and gait pre- and post-operatively. For surgery, tail nucleus pulposus (NP) tissue was collected and the right L5 dorsal root ganglion (DRG) was exposed (Day 0). In sham animals, NP tissue was discarded (n = 6); for experimental animals, autologous NP was placed on the DRG with or without 20 μg of soluble TNF receptor type II (sTNFRII, n = 6 per group). Spatiotemporal gait characteristics (open arena) and mechanical sensitivity (von Frey filaments) were assessed on post-operative Day 5; gait dynamics (force plate arena) and weight-bearing (incapacitance meter) were assessed on post-operative Day 6. Results High-speed gait characterization revealed animals with NP alone had a 5% decrease in stance time on their affected limbs on Day 5 (P ≤0.032). Ground reaction force analysis on Day 6 aligned with temporal changes observed on Day 5, with vertical impulse reduced in the affected limb of animals with NP alone (area under the vertical force-time curve, P <0.02). Concordant with gait, animals with NP alone also had some evidence of affected limb mechanical allodynia on Day 5 (P = 0.08) and reduced weight-bearing on the affected limb on Day 6 (P <0.05). Delivery of sTNFRII at the time of NP placement ameliorated signs of mechanical hypersensitivity, imbalanced weight distribution, and gait compensations (P <0.1). Conclusions Our data indicate gait characterization has value for describing early limb dysfunctions in pre-clinical models of lumbar radiculopathy. Furthermore, TNF antagonism prevented the development of gait compensations subsequent to lumbar radiculopathy in our model. PMID:21871102

  10. Effectiveness of Rehabilitation Interventions to Improve Gait Speed in Children With Cerebral Palsy: Systematic Review and Meta-analysis

    PubMed Central

    Bodkin, Amy Winter; Bjornson, Kristie; Hobbs, Amy; Soileau, Mallary; Lahasky, Kay

    2016-01-01

    Background Children with cerebral palsy (CP) have decreased gait speeds, which can negatively affect their community participation and quality of life. However, evidence for effective rehabilitation interventions to improve gait speed remains unclear. Purpose The purpose of this study was to determine the effectiveness of interventions for improving gait speed in ambulatory children with CP. Data Sources MEDLINE/PubMed, CINAHL, ERIC, and PEDro were searched from inception through April 2014. Study Selection The selected studies were randomized controlled trials or had experimental designs with a comparison group, included a physical therapy or rehabilitation intervention for children with CP, and reported gait speed as an outcome measure. Data Extraction Methodological quality was assessed by PEDro scores. Means, standard deviations, and change scores for gait speed were extracted. General study information and dosing parameters (frequency, duration, intensity, and volume) of the intervention were recorded. Data Synthesis Twenty-four studies were included. Three categories of interventions were identified: gait training (n=8), resistance training (n=9), and miscellaneous (n=7). Meta-analysis showed that gait training was effective in increasing gait speed, with a standardized effect size of 0.92 (95% confidence interval=0.19, 1.66; P=.01), whereas resistance training was shown to have a negligible effect (effect size=0.06; 95% confidence interval=−0.12, 0.25; P=.51). Effect sizes from negative to large were reported for studies in the miscellaneous category. Limitations Gait speed was the only outcome measure analyzed. Conclusions Gait training was the most effective intervention in improving gait speed for ambulatory children with CP. Strength training, even if properly dosed, was not shown to be effective in improving gait speed. Velocity training, electromyographic biofeedback training, and whole-body vibration were effective in improving gait speed in individual studies and warrant further investigation. PMID:27313240

  11. Real-time feedback to improve gait in children with cerebral palsy.

    PubMed

    van Gelder, Linda; Booth, Adam T C; van de Port, Ingrid; Buizer, Annemieke I; Harlaar, Jaap; van der Krogt, Marjolein M

    2017-02-01

    Real-time feedback may be useful for enhancing information gained from clinical gait analysis of children with cerebral palsy (CP). It may also be effective in functional gait training, however, it is not known if children with CP can adapt gait in response to real-time feedback of kinematic parameters. Sixteen children with cerebral palsy (age 6-16; GMFCS I-III), walking with a flexed-knee gait pattern, walked on an instrumented treadmill with virtual reality in three conditions: regular walking without feedback (NF), feedback on hip angle (FH) and feedback on knee angle (FK). Clinically relevant gait parameters were calculated and the gait profile score (GPS) was used as a measure of overall gait changes between conditions. All children, except one, were able to improve hip and/or knee extension during gait in response to feedback, with nine achieving a clinically relevant improvement. Peak hip extension improved significantly by 5.1±5.9° (NF: 8.9±12.8°, FH: 3.8±10.4°, p=0.01). Peak knee extension improved significantly by 7.7±7.1° (NF: 22.2±12.0°, FK: 14.5±12.7°, p<0.01). GPS did not change between conditions due to increased deviations in other gait parameters. Responders to feedback were shown to have worse initial gait as measured by GPS (p=0.005) and functional selectivity score (p=0.049). In conclusion, ambulatory children with CP show adaptability in gait and are able to respond to real-time feedback, resulting in significant and clinically relevant improvements in peak hip and knee extension. These findings show the potential of real-time feedback as a tool for functional gait training and advanced gait analysis in CP. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. A comparative analysis of spectral exponent estimation techniques for 1/fβ processes with applications to the analysis of stride interval time series

    PubMed Central

    Schaefer, Alexander; Brach, Jennifer S.; Perera, Subashan; Sejdić, Ervin

    2013-01-01

    Background The time evolution and complex interactions of many nonlinear systems, such as in the human body, result in fractal types of parameter outcomes that exhibit self similarity over long time scales by a power law in the frequency spectrum S(f) = 1/fβ. The scaling exponent β is thus often interpreted as a “biomarker” of relative health and decline. New Method This paper presents a thorough comparative numerical analysis of fractal characterization techniques with specific consideration given to experimentally measured gait stride interval time series. The ideal fractal signals generated in the numerical analysis are constrained under varying lengths and biases indicative of a range of physiologically conceivable fractal signals. This analysis is to complement previous investigations of fractal characteristics in healthy and pathological gait stride interval time series, with which this study is compared. Results The results of our analysis showed that the averaged wavelet coefficient method consistently yielded the most accurate results. Comparison with Existing Methods: Class dependent methods proved to be unsuitable for physiological time series. Detrended fluctuation analysis as most prevailing method in the literature exhibited large estimation variances. Conclusions The comparative numerical analysis and experimental applications provide a thorough basis for determining an appropriate and robust method for measuring and comparing a physiologically meaningful biomarker, the spectral index β. In consideration of the constraints of application, we note the significant drawbacks of detrended fluctuation analysis and conclude that the averaged wavelet coefficient method can provide reasonable consistency and accuracy for characterizing these fractal time series. PMID:24200509

  13. Free-living and laboratory gait characteristics in patients with multiple sclerosis

    PubMed Central

    Nair, K. P. S.; Clarke, Alison J.; Van der Meulen, Jill M.; Mazzà, Claudia

    2018-01-01

    Background Wearable sensors offer the potential to bring new knowledge to inform interventions in patients affected by multiple sclerosis (MS) by thoroughly quantifying gait characteristics and gait deficits from prolonged daily living measurements. The aim of this study was to characterise gait in both laboratory and daily life conditions for a group of patients with moderate to severe ambulatory impairment due to MS. To this purpose, algorithms to detect and characterise gait from wearable inertial sensors data were also validated. Methods Fourteen patients with MS were divided into two groups according to their disability level (EDSS 6.5–6.0 and EDSS 5.5–5.0, respectively). They performed both intermittent and continuous walking bouts (WBs) in a gait laboratory wearing waist and shank mounted inertial sensors. An algorithm (W-CWT) to estimate gait events and temporal parameters (mean and variability values) using data recorded from the waist mounted sensor (Dynaport, Mc Roberts) was tested against a reference algorithm (S-REF) based on the shank-worn sensors (OPAL, APDM). Subsequently, the accuracy of another algorithm (W-PAM) to detect and classify WBs was also tested. The validated algorithms were then used to quantify gait characteristics during short (sWB, 5–50 steps), intermediate (iWB, 51–100 steps) and long (lWB, >100 steps) daily living WBs and laboratory walking. Group means were compared using a two-way ANOVA. Results W-CWT compared to S-REF showed good gait event accuracy (0.05–0.10 s absolute error) and was not influenced by disability level. It slightly overestimated stride time in intermittent walking (0.012 s) and overestimated highly variability of temporal parameters in both intermittent (17.5%–58.2%) and continuous walking (11.2%–76.7%). The accuracy of W-PAM was speed-dependent and decreased with increasing disability. The ANOVA analysis showed that patients walked at a slower pace in daily living than in the laboratory. In daily living gait, all mean temporal parameters decreased as the WB duration increased. In the sWB, the patients with a lower disability score showed, on average, lower values of the temporal parameters. Variability decreased as the WB duration increased. Conclusions This study validated a method to quantify walking in real life in people with MS and showed how gait characteristics estimated from short walking bouts during daily living may be the most informative to quantify level of disability and effects of interventions in patients moderately affected by MS. The study provides a robust approach for the quantification of recognised clinically relevant outcomes and an innovative perspective in the study of real life walking. PMID:29715279

  14. A pilot study of randomized clinical controlled trial of gait training in subacute stroke patients with partial body-weight support electromechanical gait trainer and functional electrical stimulation: six-month follow-up.

    PubMed

    Ng, Maple F W; Tong, Raymond K Y; Li, Leonard S W

    2008-01-01

    This study aimed to assess the effectiveness of gait training using an electromechanical gait trainer with or without functional electrical stimulation for people with subacute stroke. This was a nonblinded randomized controlled trial with a 6-month follow-up. Fifty-four subjects were recruited within 6 weeks after stroke onset and were randomly assigned to 1 of 3 gait intervention groups: conventional overground gait training treatment (CT, n=21), electromechanical gait trainer (GT, n=17) and, electromechanical gait trainer with functional electrical stimulation (GT-FES, n=16). All subjects were to undergo an assigned intervention program comprising a 20-minute session every weekday for 4 weeks. The outcome measures were Functional Independence Measure, Barthel Index, Motricity Index leg subscale, Elderly Mobility Scale (EMS), Berg Balance Scale, Functional Ambulatory Category (FAC), and 5-meter walking speed test. Assessments were made at baseline, at the end of the 4-week intervention program, and 6 months after the program ended. By intention-to-treat and multivariate analysis, statistically significant differences showed up in EMS (Wilks' lambda=0.743, P=0.005), FAC (Wilks' lambda=0.744, P=0.005) and gait speed (Wilks' lambda=0.658, P<0.0001). Post hoc analysis (univariate 2-way ANCOVA) revealed that the GT and GT-FES groups showed significantly better improvement in comparison with the CT group at the end of the 4 weeks of training and in the 6-month follow-up. For the early stage after stroke, this study indicated a higher effectiveness in poststroke gait training that used an electromechanical gait trainer compared with conventional overground gait training. The training effect was sustained through to the 6-month follow-up after the intervention.

  15. Effect of Virtual Reality Training on Balance and Gait Ability in Patients With Stroke: Systematic Review and Meta-Analysis.

    PubMed

    de Rooij, Ilona J M; van de Port, Ingrid G L; Meijer, Jan-Willem G

    2016-12-01

    Virtual reality (VR) training is considered to be a promising novel therapy for balance and gait recovery in patients with stroke. The aim of this study was to conduct a systematic literature review with meta-analysis to investigate whether balance or gait training using VR is more effective than conventional balance or gait training in patients with stroke. A literature search was carried out in the databases PubMed, Embase, MEDLINE, and Cochrane Library up to December 1, 2015. Randomized controlled trials that compared the effect of balance or gait training with and without VR on balance and gait ability in patients with stroke were included. Twenty-one studies with a median PEDro score of 6.0 were included. The included studies demonstrated a significant greater effect of VR training on balance and gait recovery after stroke compared with conventional therapy as indicated with the most frequently used measures: gait speed, Berg Balance Scale, and Timed "Up & Go" Test. Virtual reality was more effective to train gait and balance than conventional training when VR interventions were added to conventional therapy and when time dose was matched. The presence of publication bias and diversity in included studies were limitations of the study. The results suggest that VR training is more effective than balance or gait training without VR for improving balance or gait ability in patients with stroke. Future studies are recommended to investigate the effect of VR on participation level with an adequate follow-up period. Overall, a positive and promising effect of VR training on balance and gait ability is expected. © 2016 American Physical Therapy Association.

  16. Enhanced data consistency of a portable gait measurement system.

    PubMed

    Lin, Hsien-I; Chiang, Y P

    2013-11-01

    A gait measurement system is a useful tool for rehabilitation applications. Such a system is used to conduct gait experiments in large workplaces such as laboratories where gait measurement equipment can be permanently installed. However, a gait measurement system should be portable if it is to be used in clinics or community centers for aged people. In a portable gait measurement system, the workspace is limited and landmarks on a subject may not be visible to the cameras during experiments. Thus, we propose a virtual-marker function to obtain positions of unseen landmarks for maintaining data consistency. This work develops a portable clinical gait measurement system consisting of lightweight motion capture devices, force plates, and a walkway assembled from plywood boards. We evaluated the portable clinic gait system with 11 normal subjects in three consecutive days in a limited experimental space. Results of gait analysis based on the verification of within-day and between-day coefficients of multiple correlations show that the proposed portable gait system is reliable.

  17. Enhanced data consistency of a portable gait measurement system

    NASA Astrophysics Data System (ADS)

    Lin, Hsien-I.; Chiang, Y. P.

    2013-11-01

    A gait measurement system is a useful tool for rehabilitation applications. Such a system is used to conduct gait experiments in large workplaces such as laboratories where gait measurement equipment can be permanently installed. However, a gait measurement system should be portable if it is to be used in clinics or community centers for aged people. In a portable gait measurement system, the workspace is limited and landmarks on a subject may not be visible to the cameras during experiments. Thus, we propose a virtual-marker function to obtain positions of unseen landmarks for maintaining data consistency. This work develops a portable clinical gait measurement system consisting of lightweight motion capture devices, force plates, and a walkway assembled from plywood boards. We evaluated the portable clinic gait system with 11 normal subjects in three consecutive days in a limited experimental space. Results of gait analysis based on the verification of within-day and between-day coefficients of multiple correlations show that the proposed portable gait system is reliable.

  18. Effects of Vojta Therapy on Gait of Children with Spastic Diplegia

    PubMed Central

    Lim, Hyungwon; Kim, Tackhoon

    2014-01-01

    [Purpose] This study aimed to investigate the effects of Vojta therapy on spatiotemporal gait parameters in children with spastic diplegia. [Methods] The study population consisted of 3 children diagnosed with spastic diplegia. The subjects were treated with Vojta therapy for 8 weeks and followed up for 8 weeks after completion of the therapy. Vicon motion analysis was used to determine the subjects’ spatiotemporal gait parameters. [Results] The following results were noted in the changes of each joint angle in the sagittal plane after Vojta therapy. Subject 1 remained in phase throughout the entire gait cycle and did not show any noticeable improvement, even demonstrating a negative range of motion when compared to the baseline. Subject 2 showed a normal anti-phase in heel strike, and the mid-stance, and swing phases. Subject 3 showed a normal anti-phase in heel strike and mid-stance, but the anti-phase during the swing phase was not significantly different from the baseline. For subjects 2 and 3, compared to the baseline, the range of motion of the hip and knee increased but the range of motion of the ankle decreased. [Conclusion] The findings of this study indicate that Vojta therapy can do a good role in improve the spatiotemporal gait parameters of children with spastic diplegia. PMID:24409030

  19. Effects of 8 weeks of mat-based Pilates exercise on gait in chronic stroke patients.

    PubMed

    Roh, SuYeon; Gil, Ho Jong; Yoon, Sukhoon

    2016-09-01

    [Purpose] The purpose of this study was to investigate the effects of an 8-week program of Pilates exercise on gait in chronic hemiplegia patients and to determine whether or not it can be used for rehabilitation in postsrtoke patients. [Subjects and Methods] Twenty individuals with unilateral chronic hemiparetic stroke (age, 66.1 ± 4.4 yrs; height, 162.3 ± 8.3 cm; weight, 67.4 ± 12.3 kg) participated in this study and were randomly allocated equally to either a Pilates exercise group or a control group. To identify the effects of Pilates exercise, a 3-D motion analysis with 8 infrared cameras was performed. [Results] For the gait parameters, improvements were found in the Pilates exercise group for all variables, and statistical significance was observed for stride length, gait velocity, knee range of motion and hip range of motion. For the asymmetry indexes, insignificant improvements were found for all variables in the Pilates exercise group. [Conclusion] In conclusion, an 8-week program of Pilates exercise had a positive influence on improving the gait ability of poststroke patients, and the intervention could be applied to poststroke patients with various levels of physical disability by adjusting the intensity of training.

  20. Effects of 8 weeks of mat-based Pilates exercise on gait in chronic stroke patients

    PubMed Central

    Roh, SuYeon; Gil, Ho Jong; Yoon, Sukhoon

    2016-01-01

    [Purpose] The purpose of this study was to investigate the effects of an 8-week program of Pilates exercise on gait in chronic hemiplegia patients and to determine whether or not it can be used for rehabilitation in postsrtoke patients. [Subjects and Methods] Twenty individuals with unilateral chronic hemiparetic stroke (age, 66.1 ± 4.4 yrs; height, 162.3 ± 8.3 cm; weight, 67.4 ± 12.3 kg) participated in this study and were randomly allocated equally to either a Pilates exercise group or a control group. To identify the effects of Pilates exercise, a 3-D motion analysis with 8 infrared cameras was performed. [Results] For the gait parameters, improvements were found in the Pilates exercise group for all variables, and statistical significance was observed for stride length, gait velocity, knee range of motion and hip range of motion. For the asymmetry indexes, insignificant improvements were found for all variables in the Pilates exercise group. [Conclusion] In conclusion, an 8-week program of Pilates exercise had a positive influence on improving the gait ability of poststroke patients, and the intervention could be applied to poststroke patients with various levels of physical disability by adjusting the intensity of training. PMID:27799706

  1. Biomechanical mechanism of lateral trunk lean gait for knee osteoarthritis patients.

    PubMed

    Tokuda, Kazuki; Anan, Masaya; Takahashi, Makoto; Sawada, Tomonori; Tanimoto, Kenji; Kito, Nobuhiro; Shinkoda, Koichi

    2018-01-03

    The biomechanical mechanism of lateral trunk lean gait employed to reduce external knee adduction moment (KAM) for knee osteoarthritis (OA) patients is not well known. This mechanism may relate to the center of mass (COM) motion. Moreover, lateral trunk lean gait may affect motor control of the COM displacement. Uncontrolled manifold (UCM) analysis is an evaluation index used to understand motor control and variability of the motor task. Here we aimed to clarify the biomechanical mechanism to reduce KAM during lateral trunk lean gait and how motor variability controls the COM displacement. Twenty knee OA patients walked under two conditions: normal and lateral trunk lean gait conditions. UCM analysis was performed with respect to the COM displacement in the frontal plane. We also determined how the variability is structured with regards to the COM displacement as a performance variable. The peak KAM under lateral trunk lean gait was lower than that under normal gait. The reduced peak KAM observed was accompanied by medially shifted knee joint center, shortened distance of the center of pressure to knee joint center, and shortened distance of the knee-ground reaction force lever arm during the stance phase. Knee OA patients with lateral trunk lean gait could maintain kinematic synergy by utilizing greater segmental configuration variance to the performance variable. However, the COM displacement variability of lateral trunk lean gait was larger than that of normal gait. Our findings may provide clinical insights to effectively evaluate and prescribe gait modification training for knee OA patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. An animal model to evaluate skin-implant-bone integration and gait with a prosthesis directly attached to the residual limb

    PubMed Central

    Farrell, Brad J; Prilutsky, Boris I; Kistenberg, Robert S; Dalton, John F; Pitkin, Mark

    2014-01-01

    Background Despite the number of advantages of bone-anchored prostheses, their use in patients is limited due to the lack of complete skin-implant integration. The objective of the present study was to develop an animal model that would permit both detailed investigations of gait with a bone-anchored limb prosthesis and histological analysis of the skin-implant-bone interface after physiological loading of the implant during standing and walking. Methods Full-body mechanics of walking in two cats was recorded and analyzed before and after implantation of a percutaneous porous titanium pylon into the right tibia and attachment of a prosthesis. The rehabilitation procedures included initial limb casting, progressively increasing loading of implant, and standing and locomotor training. Detailed histological analysis of bone and skin ingrowth into implant was performed at the end of the study. Findings The two animals adopted the bone-anchored prosthesis for standing and locomotion, although loads on the prosthetic limb during walking decreased by 22% and 62%, respectively, 4 months after implantation. The animals shifted body weight to the contralateral side and increased propulsion forces by the contralateral hindlimb. Histological analysis of the limb implants demonstrated bone and skin ingrowth. Interpretation The developed animal model to study prosthetic gait and tissue integration with the implant demonstrated that porous titanium implants may permit bone and skin integration and prosthetic gait with a prosthesis. Future studies with this model will help optimize the implant and prosthesis properties. PMID:24405567

  3. Identification of subgroups among fibromyalgia patients.

    PubMed

    Auvinet, B; Chaleil, D

    2012-09-28

    This paper presents some hypotheses concerning the identification of homogeneous subgroups among fibromyalgia (FM) patients in order to improve the management of the disease. It also reviews the available literature about this subject. Three methods for subgrouping are discussed according to clinical features, biomarkers, and gait analysis. Clinical subgrouping based on cluster analysis has been used for the identification of homogeneous subgroups of patients and, more recently, homogeneous clinical features. So far, longitudinal studies using clinical subgroups to direct treatment and predict outcome are still required. Biomarkers in FM, which is a neurobiological disease, are of promising interest, nevertheless currently, none of them can be used to subgroup FM patients. Due to the fact that cortical and subcortical mechanisms of gait control share some cognitive functions which are involved in FM, gait markers have been proposed to evaluate and to subgroup FM patients, in clinical settings. Three out of 4 core FM symptoms are linked to gait markers. Kinesia measured by means of cranio-caudal power is correlated to pain, and could be proposed to assess pain behavior (kinesiophobia). Stride frequency, which is linked to physical component, allows the identification of a hyperkinetic subgroup. Moreover, SF has been correlated to fatigue during the 6 minute walking test. Stride regularity, which expresses the unsteadiness of gait, is correlated to cognitive dysfunction in FM. Decreased stride regularity allows the recognition of a homogeneous subgroup characterized by an increased anxiety and depression, and decreased cognitive functions. These results need further studies to be validated and so used in the daily clinical practice.

  4. The Influence of a Cognitive Dual Task on the Gait Parameters of Healthy Older Adults: A Systematic Review and Meta-Analysis.

    PubMed

    Smith, Erin; Cusack, Tara; Cunningham, Caitriona; Blake, Catherine

    2017-10-01

    This review examines the effect of a dual task on the gait parameters of older adults with a mean gait speed of 1.0 m/s or greater, and the effect of type and complexity of task. A systematic review of Web of Science, PubMed, SCOPUS, Embase, and PsycINFO was performed in July 2016. Twenty-three studies (28 data sets) were reviewed and pooled for meta-analysis. The effect size on seven gait parameters was measured as the raw mean difference between single- and dual-task performance. Gait speed significantly reduced with the addition of a dual task, with increasing complexity showing greater decrements. Cadence, stride time, and measures of gait variability were all negatively affected under the dual-task condition. In older adults, the addition of a dual task significantly reduces gait speed and cadence, with possible implications for the assessment of older people, as the addition of a dual task may expose deficits not observed under single-task assessment.

  5. Robot-assisted gait training versus treadmill training in patients with Parkinson’s disease: a kinematic evaluation with gait profile score

    PubMed Central

    Galli, Manuela; Cimolin, Veronica; De Pandis, Maria Francesca; Le Pera, Domenica; Sova, Ivan; Albertini, Giorgio; Stocchi, Fabrizio; Franceschini, Marco

    2016-01-01

    Summary The purpose of this study was to quantitatively compare the effects, on walking performance, of end-effector robotic rehabilitation locomotor training versus intensive training with a treadmill in Parkinson’s disease (PD). Fifty patients with PD were randomly divided into two groups: 25 were assigned to the robot-assisted therapy group (RG) and 25 to the intensive treadmill therapy group (IG). They were evaluated with clinical examination and 3D quantitative gait analysis [gait profile score (GPS) and its constituent gait variable scores (GVSs) were calculated from gait analysis data] at the beginning (T0) and at the end (T1) of the treatment. In the RG no differences were found in the GPS, but there were significant improvements in some GVSs (Pelvic Obl and Hip Ab-Add). The IG showed no statistically significant changes in either GPS or GVSs. The end-effector robotic rehabilitation locomotor training improved gait kinematics and seems to be effective for rehabilitation in patients with mild PD. PMID:27678210

  6. Capability of 2 gait measures for detecting response to gait training in stroke survivors: Gait Assessment and Intervention Tool and the Tinetti Gait Scale.

    PubMed

    Zimbelman, Janice; Daly, Janis J; Roenigk, Kristen L; Butler, Kristi; Burdsall, Richard; Holcomb, John P

    2012-01-01

    To characterize the performance of 2 observational gait measures, the Tinetti Gait Scale (TGS) and the Gait Assessment and Intervention Tool (G.A.I.T.), in identifying improvement in gait in response to gait training. In secondary analysis from a larger study of multimodal gait training for stroke survivors, we measured gait at pre-, mid-, and posttreatment according to G.A.I.T. and TGS, assessing their capability to capture recovery of coordinated gait components. Large medical center. Cohort of stroke survivors (N=44) greater than 6 months after stroke. All subjects received 48 sessions of a multimodal gait-training protocol. Treatment consisted of 1.5 hours per session, 4 sessions per week for 12 weeks, receiving these 3 treatment aspects: (1) coordination exercise, (2) body weight-supported treadmill training, and (3) overground gait training, with 46% of subjects receiving functional electrical stimulation. All subjects were evaluated with the G.A.I.T. and TGS before and after completing the 48-session intervention. An additional evaluation was performed at midtreatment (after session 24). For the total subject sample, there were significant pre-/post-, pre-/mid-, and mid-/posttreatment gains for both the G.A.I.T. and the TGS. According to the G.A.I.T., 40 subjects (91%) showed improved scores, 2 (4%) no change, and 2 (4%) a worsening score. According to the TGS, only 26 subjects (59%) showed improved scores, 16 (36%) no change, and 1 (2%) a worsening score. For 1 treatment group of chronic stroke survivors, the TGS failed to identify a significant treatment response to gait training, whereas the G.A.I.T. measure was successful. The G.A.I.T. is more sensitive than the TGS for individual patients and group treatment response in identifying recovery of volitional control of gait components in response to gait training. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Dual-tasking and gait in people with Mild Cognitive Impairment. The effect of working memory

    PubMed Central

    Montero-Odasso, Manuel; Bergman, Howard; Phillips, Natalie A; Wong, Chek H; Sourial, Nadia; Chertkow, Howard

    2009-01-01

    Background Cognition and mobility in older adults are closely associated and they decline together with aging. Studies evaluating associations between cognitive factors and gait performance in people with Mild Cognitive Impairment (MCI) are scarce. In this study, our aim was to determine whether specific cognitive factors have a more identifiable effect on gait velocity during dual-tasking in people with MCI. Methods Fifty-five participants, mean age 77.7 (SD = 5.9), 45% women, with MCI were evaluated for global cognition, working memory, executive function, and attention. Gait Velocity (GV) was measured under a single-task condition (single GV) and under two dual-task conditions: 1) while counting backwards (counting GV), 2) while naming animals (verbal GV). Multivariable linear regression analysis was used to examine associations with an alpha-level of 0.05. Results Participants experienced a reduction in GV while engaging in dual-task challenges (p < 0.005). Low executive function and working memory performances were associated with slow single GV (p = 0.038), slow counting GV (p = 0.017), and slow verbal GV (p = 0.031). After adjustments, working memory was the only cognitive factor which remained significantly associated with a slow GV. Conclusion In older adults with MCI, low working memory performance was associated with slow GV. Dual-task conditions showed the strongest associations with gait slowing. Our findings suggest that cortical control of gait is associated with decline in working memory in people with MCI. PMID:19723315

  8. Effects of different frequencies of rhythmic auditory cueing on the stride length, cadence, and gait speed in healthy young females.

    PubMed

    Yu, Lili; Zhang, Qi; Hu, Chunying; Huang, Qiuchen; Ye, Miao; Li, Desheng

    2015-02-01

    [Purpose] The aim of this study was to explore the effects of different frequencies of rhythmic auditory cueing (RAC) on stride length, cadence, and gait speed in healthy young females. The findings of this study might be used as clinical guidance of physical therapy for choosing the suitable frequency of RAC. [Subjects] Thirteen healthy young females were recruited in this study. [Methods] Ten meters walking tests were measured in all subjects under 4 conditions with each repeated 3 times and a 3-min seated rest period between repetitions. Subjects first walked as usual and then were asked to listen carefully to the rhythm of a metronome and walk with 3 kinds of RAC (90%, 100%, and 110% of the mean cadence). The three frequencies (90%, 100%, and 110%) of RAC were randomly assigned. Gait speed, stride length, and cadence were calculated, and a statistical analysis was performed using the SPSS (version 17.0) computer package. [Results] The gait speed and cadence of 90% RAC walking showed significant decreases compared with normal walking and 100% and 110% RAC walking. The stride length, cadence, and gait speed of 110% RAC walking showed significant increases compared with normal walking and 90% and 100% RAC walking. [Conclusion] Our results showed that 110% RAC was the best of the 3 cueing frequencies for improvement of stride length, cadence, and gait speed in healthy young females.

  9. Measurement of Walking Ground Reactions in Real-Life Environments: A Systematic Review of Techniques and Technologies.

    PubMed

    Shahabpoor, Erfan; Pavic, Aleksandar

    2017-09-12

    Monitoring natural human gait in real-life environments is essential in many applications, including quantification of disease progression, monitoring the effects of treatment, and monitoring alteration of performance biomarkers in professional sports. Nevertheless, developing reliable and practical techniques and technologies necessary for continuous real-life monitoring of gait is still an open challenge. A systematic review of English-language articles from scientific databases including Scopus, ScienceDirect, Pubmed, IEEE Xplore, EBSCO and MEDLINE were carried out to analyse the 'accuracy' and 'practicality' of the current techniques and technologies for quantitative measurement of the tri-axial walking ground reactions outside the laboratory environment, and to highlight their strengths and shortcomings. In total, 679 relevant abstracts were identified, 54 full-text papers were included in the paper and the quantitative results of 17 papers were used for meta-analysis and comparison. Three classes of methods were reviewed: (1) methods based on measured kinematic data; (2) methods based on measured plantar pressure; and (3) methods based on direct measurement of ground reactions. It was found that all three classes of methods have competitive accuracy levels with methods based on direct measurement of the ground reactions showing highest accuracy while being least practical for long-term real-life measurement. On the other hand, methods that estimate ground reactions using measured body kinematics show highest practicality of the three classes of methods reviewed. Among the most prominent technical and technological challenges are: (1) reducing the size and price of tri-axial load-cells; (2) improving the accuracy of orientation measurement using IMUs; (3) minimizing the number and optimizing the location of required IMUs for kinematic measurement; (4) increasing the durability of pressure insole sensors, and (5) enhancing the robustness and versatility of the ground reactions estimation methods to include pathological gaits and natural variability of gait in real-life physical environment.

  10. Measurement of Walking Ground Reactions in Real-Life Environments: A Systematic Review of Techniques and Technologies

    PubMed Central

    Shahabpoor, Erfan; Pavic, Aleksandar

    2017-01-01

    Monitoring natural human gait in real-life environments is essential in many applications, including quantification of disease progression, monitoring the effects of treatment, and monitoring alteration of performance biomarkers in professional sports. Nevertheless, developing reliable and practical techniques and technologies necessary for continuous real-life monitoring of gait is still an open challenge. A systematic review of English-language articles from scientific databases including Scopus, ScienceDirect, Pubmed, IEEE Xplore, EBSCO and MEDLINE were carried out to analyse the ‘accuracy’ and ‘practicality’ of the current techniques and technologies for quantitative measurement of the tri-axial walking ground reactions outside the laboratory environment, and to highlight their strengths and shortcomings. In total, 679 relevant abstracts were identified, 54 full-text papers were included in the paper and the quantitative results of 17 papers were used for meta-analysis and comparison. Three classes of methods were reviewed: (1) methods based on measured kinematic data; (2) methods based on measured plantar pressure; and (3) methods based on direct measurement of ground reactions. It was found that all three classes of methods have competitive accuracy levels with methods based on direct measurement of the ground reactions showing highest accuracy while being least practical for long-term real-life measurement. On the other hand, methods that estimate ground reactions using measured body kinematics show highest practicality of the three classes of methods reviewed. Among the most prominent technical and technological challenges are: (1) reducing the size and price of tri-axial load-cells; (2) improving the accuracy of orientation measurement using IMUs; (3) minimizing the number and optimizing the location of required IMUs for kinematic measurement; (4) increasing the durability of pressure insole sensors, and (5) enhancing the robustness and versatility of the ground reactions estimation methods to include pathological gaits and natural variability of gait in real-life physical environment. PMID:28895909

  11. Gait recognition based on integral outline

    NASA Astrophysics Data System (ADS)

    Ming, Guan; Fang, Lv

    2017-02-01

    Biometric identification technology replaces traditional security technology, which has become a trend, and gait recognition also has become a hot spot of research because its feature is difficult to imitate and theft. This paper presents a gait recognition system based on integral outline of human body. The system has three important aspects: the preprocessing of gait image, feature extraction and classification. Finally, using a method of polling to evaluate the performance of the system, and summarizing the problems existing in the gait recognition and the direction of development in the future.

  12. Development of quadruped walking locomotion gait generator using a hybrid method

    NASA Astrophysics Data System (ADS)

    Jasni, F.; Shafie, A. A.

    2013-12-01

    The earth, in many areas is hardly reachable by the wheeled or tracked locomotion system. Thus, walking locomotion system is becoming a favourite option for mobile robot these days. This is because of the ability of walking locomotion to move on the rugged and unlevel terrains. However, to develop a walking locomotion gait for a robot is not a simple task. Central Pattern Generator (CPGs) method is a biological inspired method that is introduced as a method to develop the gait for the walking robot recently to tackle the issue faced by the conventional method of pre-designed trajectory based method. However, research shows that even the CPG method do have some limitations. Thus, in this paper, a hybrid method that combines CPG and the pre-designed trajectory based method is introduced to develop a walking gait for quadruped walking robot. The 3-D foot trajectories and the joint angle trajectories developed using the proposed method are compared with the data obtained via the conventional method of pre-designed trajectory to confirm the performance.

  13. Gait Analysis of Symptomatic Flatfoot in Children: An Observational Study.

    PubMed

    Kim, Ha Yong; Shin, Hyuck Soo; Ko, Jun Hyuck; Cha, Yong Han; Ahn, Jae Hoon; Hwang, Jae Yeon

    2017-09-01

    Flatfoot deformity is a lever arm disease that incurs kinetic inefficiency during gait. The purpose of this study was to measure the degree of kinetic inefficiency by comparing the gait analysis data of a flatfoot group with a normal control group. The patient group consisted of 26 children (21 males and 5 females) with symptomatic flatfoot. They were examined with gait analysis between May 2005 and February 2014. Exclusion criteria were patients with secondary flatfoot caused by neuromuscular disorders, tarsal coalition, vertical talus, or others. Patients' mean age was 9.5 years (range, 7 to 13 years). The gait analysis data of the study group and the normal control group were compared. The mean vertical ground reaction force (GRF) in the push-off phase was 0.99 for the patient group and 1.15 for the control group ( p < 0.05). The mean ankle moment in the sagittal plane during the push-off phase was 0.89 for the patient group and 1.27 for the control group ( p < 0.05). The mean ankle power in the sagittal plane during the push-off phase was 1.38 for the patient group and 2.52 for the control group ( p < 0.05). The aforementioned results show that patients with pes planovalgus had a reduction of moment, power, and GRF in the push-off phase during gait. Symptomatic flatfeet had a moment inefficiency of 30% and power inefficiency of 45% during gait compared to feet with preserved medial longitudinal arches.

  14. Clinical Gait Evaluation of Patients with Lumbar Spine Stenosis.

    PubMed

    Sun, Jun; Liu, Yan-Cheng; Yan, Song-Hua; Wang, Sha-Sha; Lester, D Kevin; Zeng, Ji-Zhou; Miao, Jun; Zhang, Kuan

    2018-02-01

    The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3, MiniSun, CA) has been developed for clinical gait evaluation, and this study was designed to evaluate the accuracy and reliability of IDEEA3 for the gait measurement of lumbar spinal stenosis (LSS) patients. Twelve healthy volunteers were recruited to compare gait cycle, cadence, step length, velocity, and number of steps between a motion analysis system and a high-speed video camera. Twenty hospitalized LSS patients were recruited for the comparison of the five parameters between the IDEEA3 and GoPro camera. Paired t-test, intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plots were used for the data analysis. The ratios of GoPro camera results to motion analysis system results, and the ratios of IDEEA3 results to GoPro camera results were all around 1.00. All P-values of paired t-tests for gait cycle, cadence, step length, and velocity were greater than 0.05, while all the ICC and CCC results were above 0.950 with P < 0.001. The measurements for gait cycle, cadence, step length, velocity, and number of steps with the GoPro camera are highly consistent with the measurements with the motion analysis system. The measurements for IDEEA3 are consistent with those for the GoPro camera. IDEEA3 can be effectively used in the gait measurement of LSS patients. © 2018 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  15. Can turned inward patella predict an excess of femoral anteversion during gait in spastic diplegic children?

    PubMed

    Simon, Anne-Laure; Presedo, Ana; Ilharreborde, Brice; Mallet, Cindy; Mazda, Keyvan; Penneçot, Georges-François

    2014-06-01

    Determining patellar orientation in the transverse plane during observational gait analysis is a fundamental aspect of physical examinations. Many physicians consider that an abnormal position of the patella in the transverse planes is only explained by a rotational abnormality of the proximal femur. A total of 188 spastic diplegic children with cerebral palsy were reviewed (376 lower limbs). The physical examination included observation of patellar orientation at midstride and measuring femoral anteversion (FA). All patients also underwent 3-dimensional (3D) computerized gait analysis of pelvic and hip rotation kinematics. Observational gait analysis and videotapes found 103 children (206 lower limbs) with inturned patella at midstance. Kinematic data from 3D gait analysis showed that the visual impression of turned inward patella was erroneous in 48 limbs. Of the remaining 158 lower limbs, 117 (74%) exhibited excessive FA and 41 (26%) did not. Of the 117 with excessive FA, kinematics showed only 66 (56%) with excessive internal hip rotation (with or without excessive internal pelvic rotation). Of the 41 lower limbs without excessive FA, 25 were explained by excessive internal pelvic rotation and 16 were explained by excessive internal hip rotation (isolated spasticity and/or contracture of internal rotator muscles). Turned inward patella was caused by isolated excessive internal pelvic rotation in 48%, excessive internal hip rotation in 35% (including 44 cases with excessive FA and 12 cases with isolated spasticity and/or contracture of internal hip rotators), and excessive internal hip rotation combined with excessive internal pelvic rotation in 17%. Excessive FA was not the only cause of turned inward patella gait and could not explain this gait anomaly by itself. Excessive internal pelvic rotation was the most frequent cause of turned inward patella gait. Level IV.

  16. Higher heritabilities for gait components than for overall gait scores may improve mobility in ducks.

    PubMed

    Duggan, Brendan M; Rae, Anne M; Clements, Dylan N; Hocking, Paul M

    2017-05-02

    Genetic progress in selection for greater body mass and meat yield in poultry has been associated with an increase in gait problems which are detrimental to productivity and welfare. The incidence of suboptimal gait in breeding flocks is controlled through the use of a visual gait score, which is a subjective assessment of walking ability of each bird. The subjective nature of the visual gait score has led to concerns over its effectiveness in reducing the incidence of suboptimal gait in poultry through breeding. The aims of this study were to assess the reliability of the current visual gait scoring system in ducks and to develop a more objective method to select for better gait. Experienced gait scorers assessed short video clips of walking ducks to estimate the reliability of the current visual gait scoring system. Kendall's coefficients of concordance between and within observers were estimated at 0.49 and 0.75, respectively. In order to develop a more objective scoring system, gait components were visually scored on more than 4000 pedigreed Pekin ducks and genetic parameters were estimated for these components. Gait components, which are a more objective measure, had heritabilities that were as good as, or better than, those of the overall visual gait score. Measurement of gait components is simpler and therefore more objective than the standard visual gait score. The recording of gait components can potentially be automated, which may increase accuracy further and may improve heritability estimates. Genetic correlations were generally low, which suggests that it is possible to use gait components to select for an overall improvement in both economic traits and gait as part of a balanced breeding programme.

  17. Early signs of gait deviation in Duchenne muscular dystrophy.

    PubMed

    Doglio, L; Pavan, E; Pernigotti, I; Petralia, P; Frigo, C; Minetti, C

    2011-12-01

    Most analytical studies found in literature only focus on specific aspects of Duchenne muscular dystrophy (DMD) gait and posture (joint range of motion, standing balance, variations of gait spatial-temporal parameters). Some of them analyze single cases and do not provide a comprehensive evaluation of locomotion. There are few studies about DMD gait patterns, most of them concerning small groups of patients, sometimes not homogeneous, in which the clinical manifestations of the next stages of DMD were present. The goal of our study was to analyze the characteristics of gait patterns in early stage patients, when clinical and functional evaluation do not allow to quantify initial walking worsening or to identify the changes adopted to compensate for muscle weakness. Gait Analysis Laboratory by using a six-camera motion capture system (Vicon, Oxford Metrics, UK), set at a sampling rate of 60 Hz. Subjects were asked to walk barefoot at their usual cadence, along a 10-m walkway, where one force platform (Kistler, Switzerland), embedded in the middle portion of the pathway, measured the foot-ground reaction forces. Retroreflective markers were placed on the subjects according to the protocol described in Davis et al. A group of 15 patients aging from 5 to 6.8 years was compared with a similar age control group composed of 9 healthy children. Spatial and temporal parameters showed significant differences between the two groups: cadence was increased and step length was decreased significantly in the DMD group. We found a significant increase in the range of anterior-posterior pelvic tilt and in pelvic rotation. In the frontal plane there was a tendency for an increased pelvic obliquity. Dynamic range of motion in sagittal plane showed a significant difference at the ankle, with an increased plantarflexion in swing in the dystrophic patients. Maximum dorsiflexion was reduced in the DMD group. Kinetic analysis showed significant differences in power generation and absorption at the hip joint and at the ankle joint. At knee there was a reduced flexor moment in mid-stance. Ankle showed a reduced dorsiflexor moment in terminal stance and pre-swing with a consequent reduction in the peak-to-peak excursion. It was shown that instrumented gait analysis, being more sensitive than other clinical and functional assessment methods, allowed to quantify the very early modifications characterizing locomotion worsening in the first stage of the DMD.

  18. Gait analysis following treadmill training with body weight support versus conventional physical therapy: a prospective randomized controlled single blind study.

    PubMed

    Lucareli, P R; Lima, M O; Lima, F P S; de Almeida, J G; Brech, G C; D'Andréa Greve, J M

    2011-09-01

    Single-blind randomized, controlled clinical study. To evaluate, using kinematic gait analysis, the results obtained from gait training on a treadmill with body weight support versus those obtained with conventional gait training and physiotherapy. Thirty patients with sequelae from traumatic incomplete spinal cord injuries at least 12 months earlier; patients were able to walk and were classified according to motor function as ASIA (American Spinal Injury Association) impairment scale C or D. Patients were divided randomly into two groups of 15 patients by the drawing of opaque envelopes: group A (weight support) and group B (conventional). After an initial assessment, both groups underwent 30 sessions of gait training. Sessions occurred twice a week, lasted for 30 min each and continued for four months. All of the patients were evaluated by a single blinded examiner using movement analysis to measure angular and linear kinematic gait parameters. Six patients (three from group A and three from group B) were excluded because they attended fewer than 85% of the training sessions. There were no statistically significant differences in intra-group comparisons among the spatial-temporal variables in group B. In group A, the following significant differences in the studied spatial-temporal variables were observed: increases in velocity, distance, cadence, step length, swing phase and gait cycle duration, in addition to a reduction in stance phase. There were also no significant differences in intra-group comparisons among the angular variables in group B. However, group A achieved significant improvements in maximum hip extension and plantar flexion during stance. Gait training with body weight support was more effective than conventional physiotherapy for improving the spatial-temporal and kinematic gait parameters among patients with incomplete spinal cord injuries.

  19. Correlations between Berg balance scale and gait speed in individuals with stroke wearing ankle-foot orthoses - a pilot study.

    PubMed

    Kobayashi, Toshiki; Leung, Aaron K L; Akazawa, Yasushi; Hutchins, Stephen W

    2016-01-01

    The Berg balance scale (BBS) is commonly used to assess balancing ability in patients with stroke. The BBS may be a good candidate for clinical assessment prior to orthotic intervention, if it correlates well with outcome measures such as gait speed. The purpose of this study was to investigate the correlation between the BBS measured prior to walking with an ankle-foot orthosis (AFO) and specific temporal-spatial parameters of gait when walking with an AFO donned. Eight individuals with chronic stroke participated in this study. Balancing ability was assessed using the BBS, while temporal-spatial parameters of gait (gait speed, bilateral step length, stride length and step width) were measured using a three-dimensional motion analysis system. The correlations between the BBS and gait parameters were investigated using a non-parametric Kendall's Tau (τ) correlation analysis. The BBS showed correlations with gait speed (τ = 0.64, p < 0.05), the step length of the affected side (τ = 0.74, p < 0.05), and the stride length (τ = 0.64, p < 0.05). Assessment of the BBS prior to AFO prescription may potentially help clinicians to estimate the gait speed achievable following orthotic intervention in patients with stroke. Implications for Rehabilitation Assessment of the BBS prior to AFO prescription may help orthotists to estimate the gait speed following an orthotic intervention in patients with stroke. Assessment of the BBS prior to AFO prescription may help orthotists to understand overall balance and postural control abilities in patients with stroke. A larger scale multifactorial analysis is warranted to confirm the results of this pilot study.

  20. Analysis of spastic gait in cervical myelopathy: Linking compression ratio to spatiotemporal and pedobarographic parameters.

    PubMed

    Nagai, Taro; Takahashi, Yasuhito; Endo, Kenji; Ikegami, Ryo; Ueno, Ryuichi; Yamamoto, Kengo

    2018-01-01

    Gait dysfunction associated with spasticity and hyperreflexia is a primary symptom in patients with compression of cervical spinal cord. The objective of this study was to link maximum compression ratio (CR) to spatiotemporal/pedobarographic parameters. Quantitative gait analysis was performed by using a pedobarograph in 75 elderly males with a wide range of cervical compression severity. CR values were characterized on T1-weighted magnetic resonance imaging (MRI). Statistical significances in gait analysis parameters (speed, cadence, stride length, step with, and toe-out angle) were evaluated among different CR groups by the non-parametric Kruskal-Wallis test followed by the Mann-Whitney U test using Bonferroni correction. The Spearman test was performed to verify correlations between CR and gait parameters. The Kruskal-Wallis test revealed significant decline in gait speed and stride length and significant increase in toe-out angle with progression of cervical compression myelopathy. The post-hoc Mann-Whitney U test showed significant differences in these parameters between the control group (0.45

  1. Development of gait segmentation methods for wearable foot pressure sensors.

    PubMed

    Crea, S; De Rossi, S M M; Donati, M; Reberšek, P; Novak, D; Vitiello, N; Lenzi, T; Podobnik, J; Munih, M; Carrozza, M C

    2012-01-01

    We present an automated segmentation method based on the analysis of plantar pressure signals recorded from two synchronized wireless foot insoles. Given the strict limits on computational power and power consumption typical of wearable electronic components, our aim is to investigate the capability of a Hidden Markov Model machine-learning method, to detect gait phases with different levels of complexity in the processing of the wearable pressure sensors signals. Therefore three different datasets are developed: raw voltage values, calibrated sensor signals and a calibrated estimation of total ground reaction force and position of the plantar center of pressure. The method is tested on a pool of 5 healthy subjects, through a leave-one-out cross validation. The results show high classification performances achieved using estimated biomechanical variables, being on average the 96%. Calibrated signals and raw voltage values show higher delays and dispersions in phase transition detection, suggesting a lower reliability for online applications.

  2. Rehabilitation of gait after stroke: a review towards a top-down approach

    PubMed Central

    2011-01-01

    This document provides a review of the techniques and therapies used in gait rehabilitation after stroke. It also examines the possible benefits of including assistive robotic devices and brain-computer interfaces in this field, according to a top-down approach, in which rehabilitation is driven by neural plasticity. The methods reviewed comprise classical gait rehabilitation techniques (neurophysiological and motor learning approaches), functional electrical stimulation (FES), robotic devices, and brain-computer interfaces (BCI). From the analysis of these approaches, we can draw the following conclusions. Regarding classical rehabilitation techniques, there is insufficient evidence to state that a particular approach is more effective in promoting gait recovery than other. Combination of different rehabilitation strategies seems to be more effective than over-ground gait training alone. Robotic devices need further research to show their suitability for walking training and their effects on over-ground gait. The use of FES combined with different walking retraining strategies has shown to result in improvements in hemiplegic gait. Reports on non-invasive BCIs for stroke recovery are limited to the rehabilitation of upper limbs; however, some works suggest that there might be a common mechanism which influences upper and lower limb recovery simultaneously, independently of the limb chosen for the rehabilitation therapy. Functional near infrared spectroscopy (fNIRS) enables researchers to detect signals from specific regions of the cortex during performance of motor activities for the development of future BCIs. Future research would make possible to analyze the impact of rehabilitation on brain plasticity, in order to adapt treatment resources to meet the needs of each patient and to optimize the recovery process. PMID:22165907

  3. Clinical Phenotype Classifications Based on Static Varus Alignment and Varus Thrust in Japanese Patients With Medial Knee Osteoarthritis

    PubMed Central

    Iijima, Hirotaka; Fukutani, Naoto; Fukumoto, Takahiko; Uritani, Daisuke; Kaneda, Eishi; Ota, Kazuo; Kuroki, Hiroshi; Matsuda, Shuichi

    2015-01-01

    Objective To investigate the association between knee pain during gait and 4 clinical phenotypes based on static varus alignment and varus thrust in patients with medial knee osteoarthritis (OA). Methods Patients in an orthopedic clinic (n = 266) diagnosed as having knee OA (Kellgren/Lawrence [K/L] grade ≥1) were divided into 4 phenotype groups according to the presence or absence of static varus alignment and varus thrust (dynamic varus): no varus (n = 173), dynamic varus (n = 17), static varus (n = 50), and static varus + dynamic varus (n = 26). The knee range of motion, spatiotemporal gait parameters, visual analog scale scores for knee pain, and scores on the Japanese Knee Osteoarthritis Measure were used to assess clinical outcomes. Multiple logistic regression analyses identified the relationship between knee pain during gait and the 4 phenotypes, adjusted for possible risk factors, including age, sex, body mass index, K/L grade, and gait velocity. Results Multiple logistic regression analysis showed that varus thrust without varus alignment was associated with knee pain during gait (odds ratio [OR] 3.30, 95% confidence interval [95% CI] 1.08–12.4), and that varus thrust combined with varus alignment was strongly associated with knee pain during gait (OR 17.1, 95% CI 3.19–320.0). Sensitivity analyses applying alternative cutoff values for defining static varus alignment showed comparable results. Conclusion Varus thrust with or without static varus alignment was associated with the occurrence of knee pain during gait. Tailored interventions based on individual malalignment phenotypes may improve clinical outcomes in patients with knee OA. PMID:26017348

  4. Balance and gait in older electroconvulsive therapy recipients: a pilot study

    PubMed Central

    Plakiotis, Chris; Barson, Fay; Vengadasalam, Bharathi; Haines, Terry P; O’Connor, Daniel W

    2013-01-01

    Background Electroconvulsive therapy (ECT) is commonly used to treat depression in older adults. Despite its efficacy in this regard, an associated increase in the risk of falls in this population is a downside of treatment. ECT research has focused on the incidence of falls, but its effect on balance and gait – intrinsic factors in instability and falls – has not been studied. Our aim was to examine changes in balance and gait among older adults before and after a single ECT session and explore the effect of patient-related and treatment factors on any changes found. Methods Participants were 21 older adults requiring ECT for depression in public psychiatric services. Patients with clinically overt mobility problems (impairing test participation or increasing the risk of falls) were excluded. Balance and gait testing 1 hour pre-ECT and 1, 2 and 3 hours post-ECT included: (1) steady standing test; (2) perturbation of standing balance by self-initiated movements; (3) perturbation of standing balance by an external perturbation; and (4) timed up and go test. Results No deterioration in test performance was found, using one-way repeated measures analysis of variance. Conclusion Balance and gait did not deteriorate immediately after ECT. Exclusion of participants with clinically overt mobility problems and falls being better attributable to factors unrelated to balance and gait (such as post-ECT confusion) may account for our findings. This research does not repudiate the occurrence of ECT-related falls but calls into question the utility of introducing routine balance and gait assessment among older ECT recipients without pre-existing mobility problems as a means of preventing them. PMID:23766650

  5. Automated health alerts from Kinect-based in-home gait measurements.

    PubMed

    Stone, Erik E; Skubic, Marjorie; Back, Jessica

    2014-01-01

    A method for automatically generating alerts to clinicians in response to changes in in-home gait parameters is investigated. Kinect-based gait measurement systems were installed in apartments in a senior living facility. The systems continuously monitored the walking speed, stride time, and stride length of apartment residents. A framework for modeling uncertainty in the residents' gait parameter estimates, which is critical for robust change detection, is developed; along with an algorithm for detecting changes that may be clinically relevant. Three retrospective case studies, of individuals who had their gait monitored for periods ranging from 12 to 29 months, are presented to illustrate use of the alert method. Evidence suggests that clinicians could be alerted to health changes at an early stage, while they are still small and interventions may be most successful. Additional potential uses are also discussed.

  6. Prediction of future falls in a community dwelling older adult population using instrumented balance and gait analysis.

    PubMed

    Bauer, C M; Gröger, I; Rupprecht, R; Marcar, V L; Gaßmann, K G

    2016-04-01

    The role of instrumented balance and gait assessment when screening for prospective fallers is currently a topic of controversial discussion. This study analyzed the association between variables derived from static posturography, instrumented gait analysis and clinical assessments with the occurrence of prospective falls in a sample of community dwelling older people. In this study 84 older people were analyzed. Based on a prospective occurrence of falls, participants were categorized into fallers and non-fallers. Variables derived from clinical assessments, static posturography and instrumented gait analysis were evaluated with respect to the association with the occurrence of prospective falls using a forward stepwise, binary, logistic regression procedure. Fallers displayed a significantly shorter single support time during walking while counting backwards, increased mediolateral to anteroposterior sway amplitude ratio, increased fast mediolateral oscillations and a larger coefficient (Coeff) of sway direction during various static posturography tests. Previous falls were insignificantly associated with the occurrence of prospective falls. Variables derived from posturography and instrumented gait analysis showed significant associations with the occurrence of prospective falls in a sample of community dwelling older adults.

  7. Gait characterization in golden retriever muscular dystrophy dogs using linear discriminant analysis.

    PubMed

    Fraysse, Bodvaël; Barthélémy, Inès; Qannari, El Mostafa; Rouger, Karl; Thorin, Chantal; Blot, Stéphane; Le Guiner, Caroline; Chérel, Yan; Hogrel, Jean-Yves

    2017-04-12

    Accelerometric analysis of gait abnormalities in golden retriever muscular dystrophy (GRMD) dogs is of limited sensitivity, and produces highly complex data. The use of discriminant analysis may enable simpler and more sensitive evaluation of treatment benefits in this important preclinical model. Accelerometry was performed twice monthly between the ages of 2 and 12 months on 8 healthy and 20 GRMD dogs. Seven accelerometric parameters were analysed using linear discriminant analysis (LDA). Manipulation of the dependent and independent variables produced three distinct models. The ability of each model to detect gait alterations and their pattern change with age was tested using a leave-one-out cross-validation approach. Selecting genotype (healthy or GRMD) as the dependent variable resulted in a model (Model 1) allowing a good discrimination between the gait phenotype of GRMD and healthy dogs. However, this model was not sufficiently representative of the disease progression. In Model 2, age in months was added as a supplementary dependent variable (GRMD_2 to GRMD_12 and Healthy_2 to Healthy_9.5), resulting in a high overall misclassification rate (83.2%). To improve accuracy, a third model (Model 3) was created in which age was also included as an explanatory variable. This resulted in an overall misclassification rate lower than 12%. Model 3 was evaluated using blinded data pertaining to 81 healthy and GRMD dogs. In all but one case, the model correctly matched gait phenotype to the actual genotype. Finally, we used Model 3 to reanalyse data from a previous study regarding the effects of immunosuppressive treatments on muscular dystrophy in GRMD dogs. Our model identified significant effect of immunosuppressive treatments on gait quality, corroborating the original findings, with the added advantages of direct statistical analysis with greater sensitivity and more comprehensible data representation. Gait analysis using LDA allows for improved analysis of accelerometry data by applying a decision-making analysis approach to the evaluation of preclinical treatment benefits in GRMD dogs.

  8. The PARAChute Project: Remote Monitoring of Posture and Gait for Fall Prevention

    NASA Astrophysics Data System (ADS)

    Hewson, David J.; Duchêne, Jacques; Charpillet, François; Saboune, Jamal; Michel-Pellegrino, Valérie; Amoud, Hassan; Doussot, Michel; Paysant, Jean; Boyer, Anne; Hogrel, Jean-Yves

    2007-12-01

    Falls in the elderly are a major public health problem due to both their frequency and their medical and social consequences. In France alone, more than two million people aged over 65 years old fall each year, leading to more than 9 000 deaths, in particular in those over 75 years old (more than 8 000 deaths). This paper describes the PARAChute project, which aims to develop a methodology that will enable the detection of an increased risk of falling in community-dwelling elderly. The methods used for a remote noninvasive assessment for static and dynamic balance assessments and gait analysis are described. The final result of the project has been the development of an algorithm for movement detection during gait and a balance signature extracted from a force plate. A multicentre longitudinal evaluation of balance has commenced in order to validate the methodologies and technologies developed in the project.

  9. [Evidence-based rehabilitation of mobility after stroke].

    PubMed

    Dohle, C; Tholen, R; Wittenberg, H; Quintern, J; Saal, S; Stephan, K M

    2016-10-01

    Approximately two thirds of stroke patients initially suffer from at least impaired mobility. Various rehabilitation concepts have been proposed. Based on the current literature, which rehabilitation methods can be recommended for improvement of gait, gait velocity, gait distance and balance? A systematic literature search was carried out for randomized clinical studies and reviews with clinically relevant outcome variables. Formulation of recommendations, separated for target variables and time after stroke. Restoration and improvement of gait function relies on a high number of repetitions of gait movements, which for more severely affected patients is preferentially machine-based. For improvement of gait velocity for less severely affected patients intensive gait training does not necessarily rely on mechanical support. Gait distance can be improved by aerobic endurance exercises with a cardiovascular effect, which have to be performed in a functional context. Improvement of balance should be achieved by intensive functional gait training. Additional stimulation techniques are only effective when included in a functionally relevant training program. These guidelines not only provide recommendations for action but also provide pathophysiological insights into functional restoration of stance and gait after stroke.

  10. Research on gait-based human identification

    NASA Astrophysics Data System (ADS)

    Li, Youguo

    Gait recognition refers to automatic identification of individual based on his/her style of walking. This paper proposes a gait recognition method based on Continuous Hidden Markov Model with Mixture of Gaussians(G-CHMM). First, we initialize a Gaussian mix model for training image sequence with K-means algorithm, then train the HMM parameters using a Baum-Welch algorithm. These gait feature sequences can be trained and obtain a Continuous HMM for every person, therefore, the 7 key frames and the obtained HMM can represent each person's gait sequence. Finally, the recognition is achieved by Front algorithm. The experiments made on CASIA gait databases obtain comparatively high correction identification ratio and comparatively strong robustness for variety of bodily angle.

  11. Exploring the feasibility and acceptability of sensor monitoring of gait and falls in the homes of persons with multiple sclerosis.

    PubMed

    Newland, Pamela; Wagner, Joanne M; Salter, Amber; Thomas, Florian P; Skubic, Marjorie; Rantz, Marilyn

    2016-09-01

    Gait parameters variability and falls are problems for persons with MS and have not been adequately captured in the home. Our goal was to explore the feasibility and acceptability of monitoring of gait and falls in the homes of persons with MS over a period of 30 days. To test the feasibility of measuring gait and falls for 30days in the home of persons with MS, spatiotemporal gait parameters stride length, stride time, and gait speed were compared. A 3D infrared depth imaging system has been developed to objectively measure gait and falls in the home environment. Participants also completed a 16-foot GaitRite electronic pathway walk to validate spatiotemporal parameters of gait (gait speed (cm/s), stride length (cm), and gait cycle time(s)) during the timed 25 foot walking test (T25FWT). We also documented barriers to feasibility of installing the in-home sensors for these participants. The results of the study suggest that the Kinect sensor may be used as an alternative device to measure gait for persons with MS, depending on the desired accuracy level. Ultimately, using in-home sensors to analyze gait parameters in real time is feasible and could lead to better analysis of gait in persons with MS. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Gait Deviations in Children With Osteogenesis Imperfecta Type I.

    PubMed

    Garman, Christina R; Graf, Adam; Krzak, Joseph; Caudill, Angela; Smith, Peter; Harris, Gerald

    2017-08-02

    Osteogenesis imperfecta (OI) is a congenital connective tissue disorder often characterized by orthopaedic complications that impact normal gait. As such, mobility is of particular interest in the OI population as it is associated with multiple aspects of participation and quality of life. The purpose of the current study was to identify and describe common gait deviations in a large sample of individuals with type I OI and speculate the etiology with a goal of improving function. Gait analysis was performed on 44 subjects with type I (11.7±3.08 y old) and 30 typically developing controls (9.54±3.1 y old ). Spatial temporal, kinematic, and kinetic gait data were calculated from the Vicon Plug-in-Gait Model. Musculoskeletal modeling of the muscle tendon lengths (MTL) was done in OpenSim 3.3 to evaluate the MTL of the gastrocnemius and gluteus maximus. The gait deviation index, a dimensionless parameter that evaluates the deviation of 9 kinematic gait parameters from a control database, was also calculated. Walking speed, single support time, stride, and step length were lower and double support time was higher in the OI group. The gait deviation index score was lower and external hip rotation angle was higher in the OI group. Peak hip flexor, knee extensor and ankle plantarflexor moments, and power generation at the ankle were lower in the OI group. MTL analysis revealed no significant length discrepancies between the OI group and the typically developing group. Together, these findings provide a comprehensive description of gait characteristics among a group of individuals with type I OI. Such data inform clinicians about specific gait deviations in this population allowing clinicians to recommend more focused interventions. Level III-case-control study.

  13. Inertial Sensors to Assess Gait Quality in Patients with Neurological Disorders: A Systematic Review of Technical and Analytical Challenges

    PubMed Central

    Vienne, Aliénor; Barrois, Rémi P.; Buffat, Stéphane; Ricard, Damien; Vidal, Pierre-Paul

    2017-01-01

    Gait disorders are major causes of falls in patients with neurological diseases. Understanding these disorders allows prevention and better insights into underlying diseases. InertiaLocoGraphy (ILG) –the quantification of gait by using inertial measurement units (IMUs) –shows great potential to address this public health challenge, but protocols vary widely and normative values of gait parameters are still unavailable. This systematic review critically compares ILG protocols, questions features extracted from inertial signals and proposes a semeiological analysis of clinimetric characteristics for use in neurological clinical routine. For this systematic review, PubMed, Cochrane and EMBASE were searched for articles assessing gait quality by using IMUs that were published from January 1, 2014 to August 31, 2016. ILG was used to assess gait in a wide range of neurological disorders – including Parkinson disease, mild cognitive impairment, Alzheimer disease, cerebral palsy, and cerebellar atrophy – as well as in the faller or frail older population and in people presenting rheumatological pathologies. However, results have not yet been driving changes in clinical practice. One reason could be that studies mainly aimed at comparing pathological gait to healthy gait, but there is stronger need for semiological descriptions of gait perturbation, severity or prognostic assessment. Furthermore, protocols used to assess gait using IMUs are too many. Likely, outcomes are highly heterogeneous and difficult to compare across large panels of studies. Therefore, homogenization is needed to foster the use of ILG to assess gait quality in neurological routine practice. The pros and cons of each protocol are emphasized so that a compromise can be reached. As well, analysis of seven complementary clinical criteria (springiness, sturdiness, smoothness, steadiness, stability, symmetry, synchronization) is advocated. PMID:28572784

  14. Pure akinesia: a kinematic analysis in a case responsive to rotigotine

    PubMed Central

    Di Fabio, Roberto; Serrao, Mariano; Pierelli, Francesco; Fragiotta, Gaia; Sandrini, Giorgio

    2013-01-01

    Summary A patient with pure akinesia is described. This rare gait disorder, poorly responsive to therapy, is characterized by gait impairment which may be associated with handwriting and speech difficulties, in the absence of further signs of extrapyramidal involvement. Here, we report the improvement in a patient suffering from pure akinesia after low doses of rotigotine, a non-ergolinic dopamine agonist, detailing the kinematic analysis before and after the treatment. After therapy, an improvement in all of the gait parameters, particularly gait speed, was observed with a trend toward normalization. Our case report suggests that rotigotine may be a therapeutic option in cases of pure akinesia. PMID:24125564

  15. Predicting ground contact events for a continuum of gait types: An application of targeted machine learning using principal component analysis.

    PubMed

    Osis, Sean T; Hettinga, Blayne A; Ferber, Reed

    2016-05-01

    An ongoing challenge in the application of gait analysis to clinical settings is the standardized detection of temporal events, with unobtrusive and cost-effective equipment, for a wide range of gait types. The purpose of the current study was to investigate a targeted machine learning approach for the prediction of timing for foot strike (or initial contact) and toe-off, using only kinematics for walking, forefoot running, and heel-toe running. Data were categorized by gait type and split into a training set (∼30%) and a validation set (∼70%). A principal component analysis was performed, and separate linear models were trained and validated for foot strike and toe-off, using ground reaction force data as a gold-standard for event timing. Results indicate the model predicted both foot strike and toe-off timing to within 20ms of the gold-standard for more than 95% of cases in walking and running gaits. The machine learning approach continues to provide robust timing predictions for clinical use, and may offer a flexible methodology to handle new events and gait types. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Natural progression of blood-induced joint damage in patients with haemophilia: clinical relevance and reproducibility of three-dimensional gait analysis.

    PubMed

    Lobet, S; Detrembleur, C; Francq, B; Hermans, C

    2010-09-01

    A major complication in haemophilia is the destruction of joint cartilage because of recurrent intraarticular and intramuscular bleeds. Therefore, joint assessment is critical to quantify the extent of joint damage, which has traditionally been evaluated using both radiological and clinical joint scores. Our study aimed to evaluate the natural progression of haemophilic arthopathy using three-dimensional gait analysis (3DGA) and to assess the reproducibility of this technique. We hypothesized that the musculoskeletal function was relatively stable in patients with haemophilia. Eighteen adults with established haemophilic arthropathies were evaluated twice by 3DGA (mean follow-up: 18 +/- 5 weeks). Unexpectedly, our findings revealed infraclinical deterioration of gait pattern, characterized by a 3.2% decrease in the recovery index, which is indicative of the subject's ability to save energy while walking. A tendency towards modification of segmental joint function was also observed. Gait analysis was sufficiently reproducible with regards to spatiotemporal parameters as well as kinetic, mechanical and energetic gait variables. The kinematic variables were reproducible in both the sagittal and frontal planes. In conclusion, 3DGA is a reproducible tool to assess abnormal gait patterns and monitor natural disease progression in haemophilic patients.

  17. [Three-dimensional gait analysis of patients with osteonecrosis of femoral head before and after treatments with vascularized greater trochanter bone flap].

    PubMed

    Cui, Daping; Zhao, Dewei

    2011-03-01

    To provide the objective basis for the evaluation of the operative results of vascularized greater trochanter bone flap in treating osteonecrosis of the femoral head (ONFH) by three-dimensional gait analysis. Between March 2006 and March 2007, 35 patients with ONFH were treated with vascularized greater trochanter bone flap, and gait analysis was made by using three-dimensional gait analysis system before operation and at 1, 2 years after operation. There were 23 males and 12 females, aged 21-52 years (mean, 35.2 years), including 8 cases of steroid-induced, 7 cases of traumatic, 6 cases of alcoholic, and 14 cases of idiopathic ONFH. The left side was involved in 15 cases, and right side in 20 cases. According to Association Research Circulation Osseous (ARCO) classification, all patients were diagnosed as having femoral-head necrosis at stage III. Preoperative Harris hip functional score (HHS) was 56.2 +/- 5.6. The disease duration was 1.5-18.6 years (mean, 5.2 years). All incisions healed at stage I without early postoperative complications of deep vein thrombosis and infections of incision. Thirty-five patients were followed up 2-3 years with an average of 2.5 years. At 2 years after operation, the HHS score was 85.8 +/- 4.1, showing significant difference when compared with the preoperative score (t = 23.200, P = 0.000). Before operation, patients showed a hip muscles gait, short gait, reduce pain gait, and the pathological gaits significantly improved at 1 year after operation. At 1 year and 2 years after operation, step frequency, pace, step length and hip flexion, hip extension, knee flexion, ankle flexion were significantly improved (P < 0.01). Acceleration-time curves showed that negative wave and spinous wave at acceleration-stance phase of front feet and hind feet in affected limb were obviously reduced at 1 year and 2 years after operation. Postoperative petronas wave appeared at swing phase; the preoperative situation was three normal phase waves. These results suggest that three-dimensional gait analysis before and after vascularized greater trochanter for ONFH can evaluate precisely hip vitodynamics variation.

  18. Interrater reliability of videotaped observational gait-analysis assessments.

    PubMed

    Eastlack, M E; Arvidson, J; Snyder-Mackler, L; Danoff, J V; McGarvey, C L

    1991-06-01

    The purpose of this study was to determine the interrater reliability of videotaped observational gait-analysis (VOGA) assessments. Fifty-four licensed physical therapists with varying amounts of clinical experience served as raters. Three patients with rheumatoid arthritis who demonstrated an abnormal gait pattern served as subjects for the videotape. The raters analyzed each patient's most severely involved knee during the four subphases of stance for the kinematic variables of knee flexion and genu valgum. Raters were asked to determine whether these variables were inadequate, normal, or excessive. The temporospatial variables analyzed throughout the entire gait cycle were cadence, step length, stride length, stance time, and step width. Generalized kappa coefficients ranged from .11 to .52. Intraclass correlation coefficients (2,1) and (3,1) were slightly higher. Our results indicate that physical therapists' VOGA assessments are only slightly to moderately reliable and that improved interrater reliability of the assessments of physical therapists utilizing this technique is needed. Our data suggest that there is a need for greater standardization of gait-analysis training.

  19. Feasibility of visual instrumented movement feedback therapy in individuals with motor incomplete spinal cord injury walking on a treadmill

    PubMed Central

    Schließmann, Daniel; Schuld, Christian; Schneiders, Matthias; Derlien, Steffen; Glöckner, Maria; Gladow, Till; Weidner, Norbert; Rupp, Rüdiger

    2014-01-01

    Background: Incomplete spinal cord injury (iSCI) leads to motor and sensory deficits. Even in ambulatory persons with good motor function an impaired proprioception may result in an insecure gait. Limited internal afferent feedback (FB) can be compensated by provision of external FB by therapists or technical systems. Progress in computational power of motion analysis systems allows for implementation of instrumented real-time FB. The aim of this study was to test if individuals with iSCI can normalize their gait kinematics during FB and more importantly maintain an improvement after therapy. Methods: Individuals with chronic iSCI had to complete 6 days (1 day per week) of treadmill-based FB training with a 2 weeks pause after 3 days of training. Each day consists of an initial gait analysis followed by 2 blocks with FB/no-FB. During FB the deviation of the mean knee angle during swing from a speed matched reference (norm distance, ND) is visualized as a number. The task consists of lowering the ND, which was updated after every stride. Prior to the tests in patients the in-house developed FB implementation was tested in healthy subjects with an artificial movement task. Results: Four of five study participants benefited from FB in the short and medium term. Decrease of mean ND was highest during the first 3 sessions (from 3.93 ± 1.54 to 2.18 ± 1.04). After the pause mean ND stayed in the same range than before. In the last 3 sessions the mean ND decreased slower (2.40 ± 1.18 to 2.20 ± 0.90). Direct influences of FB ranged from 60 to 15% of reduction in mean ND compared to initial gait analysis and from 20 to 1% compared to no-FB sessions. Conclusions: Instrumented kinematic real-time FB may serve as an effective adjunct to established gait therapies in normalizing the gait pattern after incomplete spinal cord injury. Further studies with larger patient groups need to prove long term learning and the successful transfer of newly acquired skills to activities of daily living. PMID:24987344

  20. Surgical versus conservative treatment following acute rupture of the Achilles tendon: is there a pedobarographic difference?

    PubMed

    Karaaslan, Fatih; Mermerkaya, Musa Uğur; Çıraklı, Alper; Karaoğlu, Sinan; Duygulu, Fuat

    2016-01-01

    Controversy remains regarding the optimal treatment method and postoperative rehabilitation of acute Achilles tendon ruptures. In this study, pedobarographic assessments of surgical and conservative treatments were compared. A prospective assessment was made of 16 patients (eight surgical, eight conservative) and eight healthy controls using a plantar pressure measurement system. Biomechanical gait parameters were obtained using the Footscan dynamic gait analysis system. Kruskal-Wallis and Mann-Whitney U-tests were used for the evaluation of data. Nineteen males and five females were assessed, with an average age of 42.0±11.9 years. Follow-up was completed in 16 patients. No statistically significant difference was determined between the two treatment groups with regard to the gait analysis, but a difference was observed with the control group (P<0.001). All patients were able to resume their prior activities after 6 months and regained normal ranges of motion, with a high rate of satisfaction. Most of the patients (75%) were able to return to their pre-injury level of activities. Satisfactory results were obtained through conservative treatment of acute ruptures of the Achilles tendon. No significant differences or complications were observed in the group managed conservatively versus the group treated surgically. Further studies including 3D gait analyses and tendon biomechanical research are required to further investigate this issue.

  1. IMU-Based Gait Recognition Using Convolutional Neural Networks and Multi-Sensor Fusion.

    PubMed

    Dehzangi, Omid; Taherisadr, Mojtaba; ChangalVala, Raghvendar

    2017-11-27

    The wide spread usage of wearable sensors such as in smart watches has provided continuous access to valuable user generated data such as human motion that could be used to identify an individual based on his/her motion patterns such as, gait. Several methods have been suggested to extract various heuristic and high-level features from gait motion data to identify discriminative gait signatures and distinguish the target individual from others. However, the manual and hand crafted feature extraction is error prone and subjective. Furthermore, the motion data collected from inertial sensors have complex structure and the detachment between manual feature extraction module and the predictive learning models might limit the generalization capabilities. In this paper, we propose a novel approach for human gait identification using time-frequency (TF) expansion of human gait cycles in order to capture joint 2 dimensional (2D) spectral and temporal patterns of gait cycles. Then, we design a deep convolutional neural network (DCNN) learning to extract discriminative features from the 2D expanded gait cycles and jointly optimize the identification model and the spectro-temporal features in a discriminative fashion. We collect raw motion data from five inertial sensors placed at the chest, lower-back, right hand wrist, right knee, and right ankle of each human subject synchronously in order to investigate the impact of sensor location on the gait identification performance. We then present two methods for early (input level) and late (decision score level) multi-sensor fusion to improve the gait identification generalization performance. We specifically propose the minimum error score fusion (MESF) method that discriminatively learns the linear fusion weights of individual DCNN scores at the decision level by minimizing the error rate on the training data in an iterative manner. 10 subjects participated in this study and hence, the problem is a 10-class identification task. Based on our experimental results, 91% subject identification accuracy was achieved using the best individual IMU and 2DTF-DCNN. We then investigated our proposed early and late sensor fusion approaches, which improved the gait identification accuracy of the system to 93.36% and 97.06%, respectively.

  2. Towards autonomous locomotion: CPG-based control of smooth 3D slithering gait transition of a snake-like robot.

    PubMed

    Bing, Zhenshan; Cheng, Long; Chen, Guang; Röhrbein, Florian; Huang, Kai; Knoll, Alois

    2017-04-04

    Snake-like robots with 3D locomotion ability have significant advantages of adaptive travelling in diverse complex terrain over traditional legged or wheeled mobile robots. Despite numerous developed gaits, these snake-like robots suffer from unsmooth gait transitions by changing the locomotion speed, direction, and body shape, which would potentially cause undesired movement and abnormal torque. Hence, there exists a knowledge gap for snake-like robots to achieve autonomous locomotion. To address this problem, this paper presents the smooth slithering gait transition control based on a lightweight central pattern generator (CPG) model for snake-like robots. First, based on the convergence behavior of the gradient system, a lightweight CPG model with fast computing time was designed and compared with other widely adopted CPG models. Then, by reshaping the body into a more stable geometry, the slithering gait was modified, and studied based on the proposed CPG model, including the gait transition of locomotion speed, moving direction, and body shape. In contrast to sinusoid-based method, extensive simulations and prototype experiments finally demonstrated that smooth slithering gait transition can be effectively achieved using the proposed CPG-based control method without generating undesired locomotion and abnormal torque.

  3. Target of physiological gait: Realization of speed adaptive control for a prosthetic knee during swing flexion.

    PubMed

    Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Li, Jin; Wei, Xiaodong

    2018-01-01

    Prosthetic knee is the most important component of lower limb prosthesis. Speed adaptive for prosthetic knee during swing flexion is the key method to realize physiological gait. This study aims to discuss the target of physiological gait, propose a speed adaptive control method during swing flexion and research the damping adjustment law of intelligent hydraulic prosthetic knee. According to the physiological gait trials of healthy people, the control target during swing flexion is defined. A new prosthetic knee with fuzzy logical control during swing flexion is designed to realize the damping adjustment automatically. The function simulation and evaluation system of intelligent knee prosthesis is provided. Speed adaptive control test of the intelligent prosthetic knee in different velocities are researched. The maximum swing flexion of the knee angle is set between sixty degree and seventy degree as the target of physiological gait. Preliminary experimental results demonstrate that the prosthetic knee with fuzzy logical control is able to realize physiological gait under different speeds. The faster the walking, the bigger the valve closure percentage of the hydraulic prosthetic knee. The proposed fuzzy logical control strategy and intelligent hydraulic prosthetic knee are effective for the amputee to achieve physiological gait.

  4. Effect of 24-h continuous rotigotine treatment on stationary and non-stationary locomotion in de novo patients with Parkinson disease in an open-label uncontrolled study.

    PubMed

    Serrao, Mariano; Ranavolo, Alberto; Conte, Carmela; Davassi, Chiara; Mari, Silvia; Fasano, Alfonso; Chini, Giorgia; Coppola, Gianluca; Draicchio, Francesco; Pierelli, Francesco

    2015-11-01

    The aim of this study was to investigate the effect of a rotigotine transdermal patch on stationary and non-stationary locomotion in de novo Parkinson disease (PD) patients in an open-label uncontrolled study. A 3-D gait analysis system was used to investigate four different locomotor tasks: steady-state linear walking, gait initiation, gait termination and 180°-turning. A series of gait variables were measured for each locomotor task. PD patients who received rotigotine treatment (4-8 mg) displayed: (1) increased step length, gait speed, cadence and arm oscillations, and reduced double support duration and step asymmetry during steady-state linear gait; (2) increased initial step length during gait initiation; (3) increased final step length and gait speed, and decreased stability index during gait termination; (4) decreased duration of turning and head-pelvis delays during 180°-turning. The main finding that emerges from the present study is that the dopamine agonist rotigotine can improve various aspects of gait in de novo PD patients.

  5. The effects of posterior cruciate ligament deficiency on posterolateral corner structures under gait- and squat-loading conditions

    PubMed Central

    Kang, K-T.; Koh, Y-G.; Jung, M.; Nam, J-H.; Son, J.; Lee, Y.H.

    2017-01-01

    Objectives The aim of the current study was to analyse the effects of posterior cruciate ligament (PCL) deficiency on forces of the posterolateral corner structure and on tibiofemoral (TF) and patellofemoral (PF) contact force under dynamic-loading conditions. Methods A subject-specific knee model was validated using a passive flexion experiment, electromyography data, muscle activation, and previous experimental studies. The simulation was performed on the musculoskeletal models with and without PCL deficiency using a novel force-dependent kinematics method under gait- and squat-loading conditions, followed by probabilistic analysis for material uncertain to be considered. Results Comparison of predicted passive flexion, posterior drawer kinematics and muscle activation with experimental measurements showed good agreement. Forces of the posterolateral corner structure, and TF and PF contact forces increased with PCL deficiency under gait- and squat-loading conditions. The rate of increase in PF contact force was the greatest during the squat-loading condition. The TF contact forces increased on both medial and lateral compartments during gait-loading conditions. However, during the squat-loading condition, the medial TF contact force tended to increase, while the lateral TF contact forces decreased. The posterolateral corner structure, which showed the greatest increase in force with deficiency of PCL under both gait- and squat-loading conditions, was the popliteus tendon (PT). Conclusion PCL deficiency is a factor affecting the variability of force on the PT in dynamic-loading conditions, and it could lead to degeneration of the PF joint. Cite this article: K-T. Kang, Y-G. Koh, M. Jung, J-H. Nam, J. Son, Y.H. Lee, S-J. Kim, S-H. Kim. The effects of posterior cruciate ligament deficiency on posterolateral corner structures under gait- and squat-loading conditions: A computational knee model. Bone Joint Res 2017;6:31–42. DOI: 10.1302/2046-3758.61.BJR-2016-0184.R1. PMID:28077395

  6. Three-Dimensional Kinematic Gait Analysis of Doberman Pinschers with and without Cervical Spondylomyelopathy

    PubMed Central

    Foss, K.; da Costa, R.C.; Moore, S.

    2014-01-01

    Background The optimal treatment of cervical spondylomyelopathy (CSM) is controversial, with the owner’s and clinician’s perception of gait improvement often being used as outcome measures. These methods are subjective and suffer from observer bias. Objectives To establish kinematic gait parameters utilizing digital motion capture in normal Doberman Pinschers and compare them with CSM-affected Dobermans. Animals Nineteen Doberman Pinschers; 10 clinically normal and 9 with CSM. Methods All dogs were enrolled prospectively and fitted with a Lycra® body suit, and motion capture was performed and used to reconstruct a 3-D stick diagram representation of each dog based on 32 reflective markers, from which several parameters were measured. These included stride duration, length, and height; maximal and minimal spinal angles; elbow and stifle flexion and extension; and maximum and minimum distances between the thoracic and pelvic limbs. A random-effects linear regression model was used to compare parameters between groups. Results Significant differences between groups included smaller minimum (mean = 116 mm; P = .024) and maximum (mean = 184 mm; P = .001) distance between the thoracic limbs in CSM-affected dogs. Additionally, thoracic limb stride duration was also smaller (P = .009) in CSM-affected dogs (mean = 0.7 seconds) when compared with normal dogs (mean = 0.8 seconds). In the pelvic limbs, the average stifle flexion (mean = 100°; P = .048) and extension (mean = 136°; P = .009), as well as number of strides (mean = 2.7 strides; P = .033) were different between groups. Conclusions and Clinical Importance Our findings suggest that computerized gait analysis reveals more consistent kinematic differences in the thoracic limbs, which can be used as future objective outcome measures. PMID:23194100

  7. Clinical experience using a 5-week treadmill training program with virtual reality to enhance gait in an ambulatory physical therapy service.

    PubMed

    Shema, Shirley Roth; Brozgol, Marina; Dorfman, Moran; Maidan, Inbal; Sharaby-Yeshayahu, Lior; Malik-Kozuch, Hila; Wachsler Yannai, Orly; Giladi, Nir; Hausdorff, Jeffrey M; Mirelman, Anat

    2014-09-01

    Current literature views safe gait as a complex task, relying on motor and cognitive resources. The use of virtual reality (VR) in gait training offers a multifactorial approach, showing positive effects on mobility, balance, and fall risk in elderly people and individuals with neurological disorders. This form of training has been described as a viable research tool; however, it has not been applied routinely in clinical practice. Recently, VR was used to develop an adjunct training method for use by physical therapists in an ambulatory clinical setting. The aim of this article is to describe the initial clinical experience of applying a 5-week VR clinical service to improve gait and mobility in people with a history of falls, poor mobility, or postural instability. A retrospective data analysis was conducted. The clinical records of the first 60 patients who completed the VR gait training program were examined. Training was provided 3 times per week for 5 weeks, with each session lasting approximately 1 hour and consisting of walking on a treadmill while negotiating virtual obstacles. Main outcome measures were compared across time and included the Timed "Up & Go" Test (TUG), the Two-Minute Walk Test (2MWT), and the Four Square Step Test (FSST). After 5 weeks of training, time to complete the TUG decreased by 10.3%, the distance walked during the 2MWT increased by 9.5%, and performance on the FSST improved by 13%. Limitations of the study include the use of a retrospective analysis with no control group and the lack of objective cognitive assessment. Treadmill training with VR appears to be an effective and practical tool that can be applied in an outpatient physical therapy clinic. This training apparently leads to improvements in gait, mobility, and postural control. It, perhaps, also may augment cognitive and functional aspects. © 2014 American Physical Therapy Association.

  8. Mobile gait analysis via eSHOEs instrumented shoe insoles: a pilot study for validation against the gold standard GAITRite®.

    PubMed

    Jagos, Harald; Pils, Katharina; Haller, Michael; Wassermann, Claudia; Chhatwal, Christa; Rafolt, Dietmar; Rattay, Frank

    2017-07-01

    Clinical gait analysis contributes massively to rehabilitation support and improvement of in-patient care. The research project eSHOE aspires to be a useful addition to the rich variety of gait analysis systems. It was designed to fill the gap of affordable, reasonably accurate and highly mobile measurement devices. With the overall goal of enabling individual home-based monitoring and training for people suffering from chronic diseases, affecting the locomotor system. Motion and pressure sensors gather movement data directly on the (users) feet, store them locally and/or transmit them wirelessly to a PC. A combination of pattern recognition and feature extraction algorithms translates the motion data into standard gait parameters. Accuracy of eSHOE were evaluated against the reference system GAITRite in a clinical pilot study. Eleven hip fracture patients (78.4 ± 7.7 years) and twelve healthy subjects (40.8 ± 9.1 years) were included in these trials. All subjects performed three measurements at a comfortable walking speed over 8 m, including the 6-m long GAITRite mat. Six standard gait parameters were extracted from a total of 347 gait cycles. Agreement was analysed via scatterplots, histograms and Bland-Altman plots. In the patient group, the average differences between eSHOE and GAITRite range from -0.046 to 0.045 s and in the healthy group from -0.029 to 0.029 s. Therefore, it can be concluded that eSHOE delivers adequately accurate results. Especially with the prospect as an at home supplement or follow-up to clinical gait analysis and compared to other state of the art wearable motion analysis systems.

  9. Gait analysis before and after achilles tendon surgical suture in a single-subject study: a case report.

    PubMed

    Marcolin, Giuseppe; Buriani, Alessandro; Balasso, Alberto; Villaminar, Renato; Petrone, Nicola

    2015-01-01

    Achilles tendon rupture is a disabling injury that requires a long recovery time. We describe a unique case of a 46-year-old male who had undergone gait analysis as part of a personal physical examination and who, 16 months later, ruptured his left Achilles tendon while running. With gait kinematic and kinetic data available both before and after his injury, we determined the residual gait asymmetries on his uninjured side and compared the pre- and postinjury measurements. We analyzed his gait at 1, 4, and 7 weeks after his return to full weightbearing. Compared with the preinjury values, at 7 weeks he had almost complete range of motion in his left ankle (-2%) and a slight increase in gait velocity (+6%) and cadence (+3%). The peak power of his injured ankle was 90% of its preinjury value. In contrast, the unaffected ankle was at 118%. These observations suggest that measuring the asymmetries of the gait cycle, especially at the beginning of rehabilitation, can be used to improve treatment. We had the patient strengthen his ankle using a stationary bicycle before he returned to running. Kinetics also appears to be more powerful than kinematics in detecting functional asymmetries associated with reduced calf strength, even 15 weeks after surgery. Gait analysis could be used to predict the effectiveness of rehabilitation protocols and help calibrate and monitor the return to sports participation while preventing overloading muscle and tendon syndromes. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Effect of rhythmic auditory cueing on gait in people with Alzheimer disease.

    PubMed

    Wittwer, Joanne E; Webster, Kate E; Hill, Keith

    2013-04-01

    To determine whether rhythmic music and metronome cues alter spatiotemporal gait measures and gait variability in people with Alzheimer disease (AD). A repeated-measures study requiring participants to walk under different cueing conditions. University movement laboratory. Of the people (N=46) who met study criteria (a diagnosis of probable AD and ability to walk 100m) at routine medical review, 30 (16 men; mean age ± SD, 80±6y; revised Addenbrooke's Cognitive Examination range, 26-79) volunteered to participate. Participants walked 4 times over an electronic walkway synchronizing to (1) rhythmic music and (2) a metronome set at individual mean baseline comfortable speed cadence. Gait spatiotemporal measures and gait variability (coefficient of variation [CV]). Data from individual walks under each condition were combined. A 1-way repeated-measures analysis of variance was used to compare uncued baseline, cued, and retest measures. Gait velocity decreased with both music and metronome cues compared with baseline (baseline, 110.5cm/s; music, 103.4cm/s; metronome, 105.4cm/s), primarily because of significant decreases in stride length (baseline, 120.9cm; music, 112.5cm; metronome, 114.8cm) with both cue types. This was coupled with increased stride length variability compared with baseline (baseline CV, 3.4%; music CV, 4.3%; metronome CV, 4.5%) with both cue types. These changes did not persist at (uncued) retest. Temporal variability was unchanged. Rhythmic auditory cueing at comfortable speed tempo produced deleterious effects on gait in a single session in this group with AD. The deterioration in spatial gait parameters may result from impaired executive function associated with AD. Further research should investigate whether these instantaneous cue effects are altered with more practice or with learning methods tailored to people with cognitive impairment. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. [The present state and progress of researches on gait recognition].

    PubMed

    Xue, Zhaojun; Jin, Jingna; Ming, Dong; Wan, Baikun

    2008-10-01

    Recognition by gait is a new field for the biometric recognition technology. Its aim is to recognize people and detect physiological, pathological and mental characters by their walk style. The use of gait as a biometric for human identification is promising. The technique of gait recognition, as an attractive research area of biomedical information detection, attracts more and more attention. In this paper is introduced a survey of the basic theory, existing gait recognition methods and potential prospects. The latest progress and key factors of research difficulties are analyzed, and future researches are envisaged.

  12. Multi-complexity ensemble measures for gait time series analysis: application to diagnostics, monitoring and biometrics.

    PubMed

    Gavrishchaka, Valeriy; Senyukova, Olga; Davis, Kristina

    2015-01-01

    Previously, we have proposed to use complementary complexity measures discovered by boosting-like ensemble learning for the enhancement of quantitative indicators dealing with necessarily short physiological time series. We have confirmed robustness of such multi-complexity measures for heart rate variability analysis with the emphasis on detection of emerging and intermittent cardiac abnormalities. Recently, we presented preliminary results suggesting that such ensemble-based approach could be also effective in discovering universal meta-indicators for early detection and convenient monitoring of neurological abnormalities using gait time series. Here, we argue and demonstrate that these multi-complexity ensemble measures for gait time series analysis could have significantly wider application scope ranging from diagnostics and early detection of physiological regime change to gait-based biometrics applications.

  13. Selective motor control correlates with gait abnormality in children with cerebral palsy.

    PubMed

    Chruscikowski, Emily; Fry, Nicola R D; Noble, Jonathan J; Gough, Martin; Shortland, Adam P

    2017-02-01

    Children with bilateral cerebral palsy (CP) commonly have limited selective motor control (SMC). This affects their ability to complete functional tasks. The impact of impaired SMC on walking has yet to be fully understood. Measures of SMC have been shown to correlate with specific characteristics of gait, however the impact of SMC on overall gait pattern has not been reported. This study explored SMC data collected as part of routine gait analysis in children with bilateral CP. As part of their clinical assessment, SMC was measured with the Selective Control Assessment of the Lower Extremities (SCALE) in 194 patients with bilateral cerebral palsy attending for clinical gait analysis at a single centre. Their summed SCALE score was compared with overall gait impairment, as measured by Gait Profile Score (GPS). Score on SCALE showed a significant negative correlation with GPS (r s =-0.603, p<0.001). Cerebral injuries in CP result in damage to the motor tracts responsible for SMC. Our results indicate that this damage is also associated with changes in the development of walking pattern in children with CP. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Gait dynamics to optimize fall risk assessment in geriatric patients admitted to an outpatient diagnostic clinic

    PubMed Central

    de Groot, Maartje H.; van Campen, Jos P.; Beijnen, Jos H.; Hortobágyi, Tibor; Vuillerme, Nicolas; Lamoth, Claudine C. J.

    2017-01-01

    Fall prediction in geriatric patients remains challenging because the increased fall risk involves multiple, interrelated factors caused by natural aging and/or pathology. Therefore, we used a multi-factorial statistical approach to model categories of modifiable fall risk factors among geriatric patients to identify fallers with highest sensitivity and specificity with a focus on gait performance. Patients (n = 61, age = 79; 41% fallers) underwent extensive screening in three categories: (1) patient characteristics (e.g., handgrip strength, medication use, osteoporosis-related factors) (2) cognitive function (global cognition, memory, executive function), and (3) gait performance (speed-related and dynamic outcomes assessed by tri-axial trunk accelerometry). Falls were registered prospectively (mean follow-up 8.6 months) and one year retrospectively. Principal Component Analysis (PCA) on 11 gait variables was performed to determine underlying gait properties. Three fall-classification models were then built using Partial Least Squares–Discriminant Analysis (PLS-DA), with separate and combined analyses of the fall risk factors. PCA identified ‘pace’, ‘variability’, and ‘coordination’ as key properties of gait. The best PLS-DA model produced a fall classification accuracy of AUC = 0.93. The specificity of the model using patient characteristics was 60% but reached 80% when cognitive and gait outcomes were added. The inclusion of cognition and gait dynamics in fall classification models reduced misclassification. We therefore recommend assessing geriatric patients’ fall risk using a multi-factorial approach that incorporates patient characteristics, cognition, and gait dynamics. PMID:28575126

  15. Gait dynamics to optimize fall risk assessment in geriatric patients admitted to an outpatient diagnostic clinic.

    PubMed

    Kikkert, Lisette H J; de Groot, Maartje H; van Campen, Jos P; Beijnen, Jos H; Hortobágyi, Tibor; Vuillerme, Nicolas; Lamoth, Claudine C J

    2017-01-01

    Fall prediction in geriatric patients remains challenging because the increased fall risk involves multiple, interrelated factors caused by natural aging and/or pathology. Therefore, we used a multi-factorial statistical approach to model categories of modifiable fall risk factors among geriatric patients to identify fallers with highest sensitivity and specificity with a focus on gait performance. Patients (n = 61, age = 79; 41% fallers) underwent extensive screening in three categories: (1) patient characteristics (e.g., handgrip strength, medication use, osteoporosis-related factors) (2) cognitive function (global cognition, memory, executive function), and (3) gait performance (speed-related and dynamic outcomes assessed by tri-axial trunk accelerometry). Falls were registered prospectively (mean follow-up 8.6 months) and one year retrospectively. Principal Component Analysis (PCA) on 11 gait variables was performed to determine underlying gait properties. Three fall-classification models were then built using Partial Least Squares-Discriminant Analysis (PLS-DA), with separate and combined analyses of the fall risk factors. PCA identified 'pace', 'variability', and 'coordination' as key properties of gait. The best PLS-DA model produced a fall classification accuracy of AUC = 0.93. The specificity of the model using patient characteristics was 60% but reached 80% when cognitive and gait outcomes were added. The inclusion of cognition and gait dynamics in fall classification models reduced misclassification. We therefore recommend assessing geriatric patients' fall risk using a multi-factorial approach that incorporates patient characteristics, cognition, and gait dynamics.

  16. Using the Oxford Foot Model to determine the association between objective measures of foot function and results of the AOFAS Ankle-Hindfoot Scale and the Foot Function Index: a prospective gait analysis study in Germany

    PubMed Central

    Kostuj, Tanja; Stief, Felix; Hartmann, Kirsten Anna; Schaper, Katharina; Arabmotlagh, Mohammad; Baums, Mike H; Meurer, Andrea; Krummenauer, Frank; Lieske, Sebastian

    2018-01-01

    Objective After cross-cultural adaption for the German translation of the Ankle-Hindfoot Scale of the American Orthopaedic Foot and Ankle Society (AOFAS-AHS) and agreement analysis with the Foot Function Index (FFI-D), the following gait analysis study using the Oxford Foot Model (OFM) was carried out to show which of the two scores better correlates with objective gait dysfunction. Design and participants Results of the AOFAS-AHS and FFI-D, as well as data from three-dimensional gait analysis were collected from 20 patients with mild to severe ankle and hindfoot pathologies. Kinematic and kinetic gait data were correlated with the results of the total AOFAS scale and FFI-D as well as the results of those items representing hindfoot function in the AOFAS-AHS assessment. With respect to the foot disorders in our patients (osteoarthritis and prearthritic conditions), we correlated the total range of motion (ROM) in the ankle and subtalar joints as identified by the OFM with values identified during clinical examination ‘translated’ into score values. Furthermore, reduced walking speed, reduced step length and reduced maximum ankle power generation during push-off were taken into account and correlated to gait abnormalities described in the scores. An analysis of correlations with CIs between the FFI-D and the AOFAS-AHS items and the gait parameters was performed by means of the Jonckheere-Terpstra test; furthermore, exploratory factor analysis was applied to identify common information structures and thereby redundancy in the FFI-D and the AOFAS-AHS items. Results Objective findings for hindfoot disorders, namely a reduced ROM, in the ankle and subtalar joints, respectively, as well as reduced ankle power generation during push-off, showed a better correlation with the AOFAS-AHS total score—as well as AOFAS-AHS items representing ROM in the ankle, subtalar joints and gait function—compared with the FFI-D score. Factor analysis, however, could not identify FFI-D items consistently related to these three indicator parameters (pain, disability and function) found in the AOFAS-AHS. Furthermore, factor analysis did not support stratification of the FFI-D into two subscales. Conclusions The AOFAS-AHS showed a good agreement with objective gait parameters and is therefore better suited to evaluate disability and functional limitations of patients suffering from foot and ankle pathologies compared with the FFI-D. PMID:29626046

  17. View-Invariant Gait Recognition Through Genetic Template Segmentation

    NASA Astrophysics Data System (ADS)

    Isaac, Ebenezer R. H. P.; Elias, Susan; Rajagopalan, Srinivasan; Easwarakumar, K. S.

    2017-08-01

    Template-based model-free approach provides by far the most successful solution to the gait recognition problem in literature. Recent work discusses how isolating the head and leg portion of the template increase the performance of a gait recognition system making it robust against covariates like clothing and carrying conditions. However, most involve a manual definition of the boundaries. The method we propose, the genetic template segmentation (GTS), employs the genetic algorithm to automate the boundary selection process. This method was tested on the GEI, GEnI and AEI templates. GEI seems to exhibit the best result when segmented with our approach. Experimental results depict that our approach significantly outperforms the existing implementations of view-invariant gait recognition.

  18. A comparative analysis of spectral exponent estimation techniques for 1/f(β) processes with applications to the analysis of stride interval time series.

    PubMed

    Schaefer, Alexander; Brach, Jennifer S; Perera, Subashan; Sejdić, Ervin

    2014-01-30

    The time evolution and complex interactions of many nonlinear systems, such as in the human body, result in fractal types of parameter outcomes that exhibit self similarity over long time scales by a power law in the frequency spectrum S(f)=1/f(β). The scaling exponent β is thus often interpreted as a "biomarker" of relative health and decline. This paper presents a thorough comparative numerical analysis of fractal characterization techniques with specific consideration given to experimentally measured gait stride interval time series. The ideal fractal signals generated in the numerical analysis are constrained under varying lengths and biases indicative of a range of physiologically conceivable fractal signals. This analysis is to complement previous investigations of fractal characteristics in healthy and pathological gait stride interval time series, with which this study is compared. The results of our analysis showed that the averaged wavelet coefficient method consistently yielded the most accurate results. Class dependent methods proved to be unsuitable for physiological time series. Detrended fluctuation analysis as most prevailing method in the literature exhibited large estimation variances. The comparative numerical analysis and experimental applications provide a thorough basis for determining an appropriate and robust method for measuring and comparing a physiologically meaningful biomarker, the spectral index β. In consideration of the constraints of application, we note the significant drawbacks of detrended fluctuation analysis and conclude that the averaged wavelet coefficient method can provide reasonable consistency and accuracy for characterizing these fractal time series. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Novel approach to ambulatory assessment of human segmental orientation on a wearable sensor system.

    PubMed

    Liu, Kun; Liu, Tao; Shibata, Kyoko; Inoue, Yoshio; Zheng, Rencheng

    2009-12-11

    A new method using a double-sensor difference based algorithm for analyzing human segment rotational angles in two directions for segmental orientation analysis in the three-dimensional (3D) space was presented. A wearable sensor system based only on triaxial accelerometers was developed to obtain the pitch and yaw angles of thigh segment with an accelerometer approximating translational acceleration of the hip joint and two accelerometers measuring the actual accelerations on the thigh. To evaluate the method, the system was first tested on a 2 degrees of freedom mechanical arm assembled out of rigid segments and encoders. Then, to estimate the human segmental orientation, the wearable sensor system was tested on the thighs of eight volunteer subjects, who walked in a straight forward line in the work space of an optical motion analysis system at three self-selected speeds: slow, normal and fast. In the experiment, the subject was assumed to walk in a straight forward way with very little trunk sway, skin artifacts and no significant internal/external rotation of the leg. The root mean square (RMS) errors of the thigh segment orientation measurement were between 2.4 degrees and 4.9 degrees during normal gait that had a 45 degrees flexion/extension range of motion. Measurement error was observed to increase with increasing walking speed probably because of the result of increased trunk sway, axial rotation and skin artifacts. The results show that, without integration and switching between different sensors, using only one kind of sensor, the wearable sensor system is suitable for ambulatory analysis of normal gait orientation of thigh and shank in two directions of the segment-fixed local coordinate system in 3D space. It can then be applied to assess spatio-temporal gait parameters and monitoring the gait function of patients in clinical settings.

  20. Timing of intermittent torque control with wire-driven gait training robot lifting toe trajectory for trip avoidance.

    PubMed

    Miyake, Tamon; Kobayashi, Yo; Fujie, Masakatsu G; Sugano, Shigeki

    2017-07-01

    Gait training robots are useful for changing gait patterns and decreasing risk of trip. Previous research has reported that decreasing duration of the assistance or guidance of the robot is beneficial for efficient gait training. Although robotic intermittent control method for assisting joint motion has been established, the effect of the robot intervention timing on change of toe clearance is unclear. In this paper, we tested different timings of applying torque to the knee, employing the intermittent control of a gait training robot to increase toe clearance throughout the swing phase. We focused on knee flexion motion and designed a gait training robot that can apply flexion torque to the knee with a wire-driven system. We used a method of timing detecting for the robot conducting torque control based on information from the hip, knee, and ankle angles to establish a non-time dependent parameter that can be used to adapt to gait change, such as gait speed. We carried out an experiment in which the conditions were four time points: starting the swing phase, lifting the foot, maintaining knee flexion, and finishing knee flexion. The results show that applying flexion torque to the knee at the time point when people start lifting their toe is effective for increasing toe clearance in the whole swing phase.

  1. Approach for gait analysis in persons with limb loss including residuum and prosthesis socket dynamics.

    PubMed

    LaPrè, A K; Price, M A; Wedge, R D; Umberger, B R; Sup, Frank C

    2018-04-01

    Musculoskeletal modeling and marker-based motion capture techniques are commonly used to quantify the motions of body segments, and the forces acting on them during human gait. However, when these techniques are applied to analyze the gait of people with lower limb loss, the clinically relevant interaction between the residual limb and prosthesis socket is typically overlooked. It is known that there is considerable motion and loading at the residuum-socket interface, yet traditional gait analysis techniques do not account for these factors due to the inability to place tracking markers on the residual limb inside of the socket. In the present work, we used a global optimization technique and anatomical constraints to estimate the motion and loading at the residuum-socket interface as part of standard gait analysis procedures. We systematically evaluated a range of parameters related to the residuum-socket interface, such as the number of degrees of freedom, and determined the configuration that yields the best compromise between faithfully tracking experimental marker positions while yielding anatomically realistic residuum-socket kinematics and loads that agree with data from the literature. Application of the present model to gait analysis for people with lower limb loss will deepen our understanding of the biomechanics of walking with a prosthesis, which should facilitate the development of enhanced rehabilitation protocols and improved assistive devices. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Reduction of genu recurvatum through adjustment of plantarflexion resistance of an articulated ankle-foot orthosis in individuals post stroke

    PubMed Central

    Kobayashi, Toshiki; Orendurff, Michael S.; Singer, Madeline L.; Gao, Fan; Daly, Wayne K.; Foreman, K. Bo

    2016-01-01

    Background Genu recurvatum (knee hyperextension) is a common issue for individuals post stroke. Ankle-foot orthoses are used to improve genu recurvatum, but evidence is limited concerning their effectiveness. Therefore, the aim of this study was to investigate the effect of changing the plantarflexion resistance of an articulated ankle-foot orthosis on genu recurvatum in patients post stroke. Methods Gait analysis was performed on 6 individuals post stroke with genu recurvatum using an articulated ankle-foot orthosis whose plantarflexion resistance was adjustable at four levels. Gait data were collected using a Bertec split-belt instrumented treadmill in a 3-dimensional motion analysis laboratory. Gait parameters were extracted and plotted for each subject under the four plantarflexion resistance conditions of the ankle-foot orthosis. Gait parameters included: a) peak ankle plantarflexion angle, b) peak ankle dorsiflexion moment, c) peak knee extension angle and d) peak knee flexion moment. A non-parametric Friedman test was performed followed by a post-hoc Wilcoxon Signed-Rank test for statistical analyses. Findings All the gait parameters demonstrated statistically significant differences among the four resistance conditions of the AFO. Increasing the amount of plantarflexion resistance of the ankle-foot orthosis generally reduced genu recurvatum in all subjects. However, individual analyses showed that the responses to the changes in the plantarflexion resistance of the AFO were not necessarily linear, and appear unique to each subject. Interpretations The plantarflexion resistance of an articulated AFO should be adjusted to improve genu recurvatum in patients post stroke. Future studies should investigate what clinical factors would influence the individual differences. PMID:27136122

  3. Sex-specific gait adaptations prior to and up to six months after ACL reconstruction

    PubMed Central

    Stasi, Stephanie L. Di; Hartigan, Erin H.; Snyder-Mackler, Lynn

    2015-01-01

    STUDY DESIGN Controlled longitudinal laboratory study. OBJECTIVES Compare sagittal plane gait mechanics of men and women before and up to 6 months after anterior cruciate ligament reconstruction (ACLR). BACKGROUND Aberrant gait patterns are ubiquitous after anterior cruciate ligament (ACL) rupture and persist after ACLR despite skilled physical therapy. Sex influences post-operative function and second ACL injury risk, but its influence on gait adaptations after injury have not been investigated. METHODS Sagittal plane knee and hip joint excursions during midstance and internal knee and hip extension moments at peak knee flexion were collected on 12 women and 27 men using 3-dimensional gait analysis before (Screen) and after pre-operative physical therapy (Pre-sx), and 6 months after ACLR (6mo). Repeated measures analysis of variance models were used to determine whether limb asymmetries changed differently over time in men and women. RESULTS Significant time x limb x sex interactions were identified for hip and knee excursions and internal knee extension moments (P≤.007). Both sexes demonstrated smaller knee excursions on the involved compared to the uninvolved knee at each time point (P≤.007), but only women demonstrated a decrease in the involved knee excursion from pre-sx to 6mo (P=.03). Women also demonstrated smaller hip excursions (P<.001) and internal knee extension moments (P=.005) on the involved limb compared to the uninvolved limb at 6mo. Men demonstrated smaller hip excursions and knee moments on the involved limb compared to the uninvolved limb (main effects, P<.001). CONCLUSION The persistence of limb asymmetries in men and women 6 months after ACLR indicates that current rehabilitation efforts are inadequate for some individuals following ACLR. PMID:25627155

  4. External Mechanical Work and Pendular Energy Transduction of Overground and Treadmill Walking in Adolescents with Unilateral Cerebral Palsy

    PubMed Central

    Zollinger, Marie; Degache, Francis; Currat, Gabriel; Pochon, Ludmila; Peyrot, Nicolas; Newman, Christopher J.; Malatesta, Davide

    2016-01-01

    Purpose: Motor impairments affect functional abilities and gait in children and adolescents with cerebral palsy (CP). Improving their walking is an essential objective of treatment, and the use of a treadmill for gait analysis and training could offer several advantages in adolescents with CP. However, there is a controversy regarding the similarity between treadmill and overground walking both for gait analysis and training in children and adolescents. The aim of this study was to compare the external mechanical work and pendular energy transduction of these two types of gait modalities at standard and preferred walking speeds in adolescents with unilateral cerebral palsy (UCP) and typically developing (TD) adolescents matched on age, height and body mass. Methods: Spatiotemporal parameters, external mechanical work and pendular energy transduction of walking were computed using two inertial sensors equipped with a triaxial accelerometer and gyroscope and compared in 10 UCP (14.2 ± 1.7 year) and 10 TD (14.1 ± 1.9 year) adolescents during treadmill and overground walking at standard and preferred speeds. Results: The treadmill induced almost identical mechanical changes to overground walking in TD adolescents and those with UCP, with the exception of potential and kinetic vertical and lateral mechanical works, which are both significantly increased in the overground-treadmill transition only in UCP (P < 0.05). Conclusions: Adolescents with UCP have a reduced adaptive capacity in absorbing and decelerating the speed created by a treadmill (i.e., dynamic stability) compared to TD adolescents. This may have an important implication in rehabilitation programs that assess and train gait by using a treadmill in adolescents with UCP. PMID:27148062

  5. Robotic Gait Training for Individuals With Cerebral Palsy: A Systematic Review and Meta-Analysis.

    PubMed

    Carvalho, Igor; Pinto, Sérgio Medeiros; Chagas, Daniel das Virgens; Praxedes Dos Santos, Jomilto Luiz; de Sousa Oliveira, Tainá; Batista, Luiz Alberto

    2017-11-01

    To identify the effects of robotic gait training practices in individuals with cerebral palsy. The search was performed in the following electronic databases: PubMed, Embase, Medline (OvidSP), Cochrane Database of Systematic Reviews, Web of Science, Scopus, Compendex, IEEE Xplore, ScienceDirect, Academic Search Premier, and Physiotherapy Evidence Database. Studies were included if they fulfilled the following criteria: (1) they investigated the effects of robotic gait training, (2) they involved patients with cerebral palsy, and (3) they enrolled patients classified between levels I and IV using the Gross Motor Function Classification System. The information was extracted from the selected articles using the descriptive-analytical method. The Critical Review Form for Quantitative Studies was used to quantitate the presence of critical components in the articles. To perform the meta-analysis, the effects of the intervention were quantified by effect size (Cohen d). Of the 133 identified studies, 10 met the inclusion criteria. The meta-analysis showed positive effects on gait speed (.21 [-.09, .51]), endurance (.21 [-.06, .49]), and gross motor function in dimension D (.18 [-.10, .45]) and dimension E (0.12 [-.15, .40]). The results obtained suggest that this training benefits people with cerebral palsy, specifically by increasing walking speed and endurance and improving gross motor function. For future studies, we suggest investigating device configuration parameters and conducting a large number of randomized controlled trials with larger sample sizes and individuals with homogeneous impairment. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  6. Influence of different safety shoes on gait and plantar pressure: a standardized examination of workers in the automotive industry

    PubMed Central

    Ochsmann, Elke; Noll, Ulrike; Ellegast, Rolf; Hermanns, Ingo; Kraus, Thomas

    2016-01-01

    Objective: Working conditions, such as walking and standing on hard surfaces, can increase the development of musculoskeletal complaints. At the interface between flooring and musculoskeletal system, safety shoes may play an important role in the well-being of employees. The aim of this study was to evaluate the effects of different safety shoes on gait and plantar pressure distributions on industrial flooring. Methods: Twenty automotive workers were individually fitted out with three different pairs of safety shoes ( "normal" shoes, cushioned shoes, and midfoot bearing shoes). They walked at a given speed of 1.5 m/s. The CUELA measuring system and shoe insoles were used for gait analysis and plantar pressure measurements, respectively. Statistical analysis was conducted by ANOVA analysis for repeated measures. Results: Walking with cushioned safety shoes or a midfoot bearing safety shoe led to a significant decrease of the average trunk inclination (p<0.005). Furthermore, the average hip flexion angle decreased for cushioned shoes as well as midfoot bearing shoes (p<0.002). The range of motion of the knee joint increased for cushioned shoes. As expected, plantar pressure distributions varied significantly between cushioned or midfoot bearing shoes and shoes without ergonomic components. Conclusion: The overall function of safety shoes is the avoidance of injury in case of an industrial accident, but in addition, safety shoes could be a long-term preventive instrument for maintaining health of the employees' musculoskeletal system, as they are able to affect gait parameters. Further research needs to focus on safety shoes in working situations. PMID:27488038

  7. Lameness detection challenges in automated milking systems addressed with partial least squares discriminant analysis.

    PubMed

    Garcia, E; Klaas, I; Amigo, J M; Bro, R; Enevoldsen, C

    2014-12-01

    Lameness causes decreased animal welfare and leads to higher production costs. This study explored data from an automatic milking system (AMS) to model on-farm gait scoring from a commercial farm. A total of 88 cows were gait scored once per week, for 2 5-wk periods. Eighty variables retrieved from AMS were summarized week-wise and used to predict 2 defined classes: nonlame and clinically lame cows. Variables were represented with 2 transformations of the week summarized variables, using 2-wk data blocks before gait scoring, totaling 320 variables (2 × 2 × 80). The reference gait scoring error was estimated in the first week of the study and was, on average, 15%. Two partial least squares discriminant analysis models were fitted to parity 1 and parity 2 groups, respectively, to assign the lameness class according to the predicted probability of being lame (score 3 or 4/4) or not lame (score 1/4). Both models achieved sensitivity and specificity values around 80%, both in calibration and cross-validation. At the optimum values in the receiver operating characteristic curve, the false-positive rate was 28% in the parity 1 model, whereas in the parity 2 model it was about half (16%), which makes it more suitable for practical application; the model error rates were, 23 and 19%, respectively. Based on data registered automatically from one AMS farm, we were able to discriminate nonlame and lame cows, where partial least squares discriminant analysis achieved similar performance to the reference method. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Automatic detection of health changes using statistical process control techniques on measured transfer times of elderly.

    PubMed

    Baldewijns, Greet; Luca, Stijn; Nagels, William; Vanrumste, Bart; Croonenborghs, Tom

    2015-01-01

    It has been shown that gait speed and transfer times are good measures of functional ability in elderly. However, data currently acquired by systems that measure either gait speed or transfer times in the homes of elderly people require manual reviewing by healthcare workers. This reviewing process is time-consuming. To alleviate this burden, this paper proposes the use of statistical process control methods to automatically detect both positive and negative changes in transfer times. Three SPC techniques: tabular CUSUM, standardized CUSUM and EWMA, known for their ability to detect small shifts in the data, are evaluated on simulated transfer times. This analysis shows that EWMA is the best-suited method with a detection accuracy of 82% and an average detection time of 9.64 days.

  9. Sensitivity analysis of multi-objective optimization of CPG parameters for quadruped robot locomotion

    NASA Astrophysics Data System (ADS)

    Oliveira, Miguel; Santos, Cristina P.; Costa, Lino

    2012-09-01

    In this paper, a study based on sensitivity analysis is performed for a gait multi-objective optimization system that combines bio-inspired Central Patterns Generators (CPGs) and a multi-objective evolutionary algorithm based on NSGA-II. In this system, CPGs are modeled as autonomous differential equations, that generate the necessary limb movement to perform the required walking gait. In order to optimize the walking gait, a multi-objective problem with three conflicting objectives is formulated: maximization of the velocity, the wide stability margin and the behavioral diversity. The experimental results highlight the effectiveness of this multi-objective approach and the importance of the objectives to find different walking gait solutions for the quadruped robot.

  10. IMU-Based Joint Angle Measurement for Gait Analysis

    PubMed Central

    Seel, Thomas; Raisch, Jorg; Schauer, Thomas

    2014-01-01

    This contribution is concerned with joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid assuming certain orientations in which the sensors are mounted with respect to the body segments. After a review of available methods that may cope with this challenge, we present a set of new methods for: (1) joint axis and position identification; and (2) flexion/extension joint angle measurement. In particular, we propose methods that use only gyroscopes and accelerometers and, therefore, do not rely on a homogeneous magnetic field. We provide results from gait trials of a transfemoral amputee in which we compare the inertial measurement unit (IMU)-based methods to an optical 3D motion capture system. Unlike most authors, we place the optical markers on anatomical landmarks instead of attaching them to the IMUs. Root mean square errors of the knee flexion/extension angles are found to be less than 1° on the prosthesis and about 3° on the human leg. For the plantar/dorsiflexion of the ankle, both deviations are about 1°. PMID:24743160

  11. Human gait recognition by pyramid of HOG feature on silhouette images

    NASA Astrophysics Data System (ADS)

    Yang, Guang; Yin, Yafeng; Park, Jeanrok; Man, Hong

    2013-03-01

    As a uncommon biometric modality, human gait recognition has a great advantage of identify people at a distance without high resolution images. It has attracted much attention in recent years, especially in the fields of computer vision and remote sensing. In this paper, we propose a human gait recognition framework that consists of a reliable background subtraction method followed by the pyramid of Histogram of Gradient (pHOG) feature extraction on the silhouette image, and a Hidden Markov Model (HMM) based classifier. Through background subtraction, the silhouette of human gait in each frame is extracted and normalized from the raw video sequence. After removing the shadow and noise in each region of interest (ROI), pHOG feature is computed on the silhouettes images. Then the pHOG features of each gait class will be used to train a corresponding HMM. In the test stage, pHOG feature will be extracted from each test sequence and used to calculate the posterior probability toward each trained HMM model. Experimental results on the CASIA Gait Dataset B1 demonstrate that with our proposed method can achieve very competitive recognition rate.

  12. Agreement between the spatio-temporal gait parameters from treadmill-based photoelectric cell and the instrumented treadmill system in healthy young adults and stroke patients.

    PubMed

    Lee, Myungmo; Song, Changho; Lee, Kyoungjin; Shin, Doochul; Shin, Seungho

    2014-07-14

    Treadmill gait analysis was more advantageous than over-ground walking because it allowed continuous measurements of the gait parameters. The purpose of this study was to investigate the concurrent validity and the test-retest reliability of the OPTOGait photoelectric cell system against the treadmill-based gait analysis system by assessing spatio-temporal gait parameters. Twenty-six stroke patients and 18 healthy adults were asked to walk on the treadmill at their preferred speed. The concurrent validity was assessed by comparing data obtained from the 2 systems, and the test-retest reliability was determined by comparing data obtained from the 1st and the 2nd session of the OPTOGait system. The concurrent validity, identified by the intra-class correlation coefficients (ICC [2, 1]), coefficients of variation (CVME), and 95% limits of agreement (LOA) for the spatial-temporal gait parameters, were excellent but the temporal parameters expressed as a percentage of the gait cycle were poor. The test-retest reliability of the OPTOGait System, identified by ICC (3, 1), CVME, 95% LOA, standard error of measurement (SEM), and minimum detectable change (MDC95%) for the spatio-temporal gait parameters, was high. These findings indicated that the treadmill-based OPTOGait System had strong concurrent validity and test-retest reliability. This portable system could be useful for clinical assessments.

  13. Upper limb movement analysis during gait in multiple sclerosis patients.

    PubMed

    Elsworth-Edelsten, Charlotte; Bonnefoy-Mazure, Alice; Laidet, Magali; Armand, Stephane; Assal, Frederic; Lalive, Patrice; Allali, Gilles

    2017-08-01

    Gait disorders in multiple sclerosis (MS) are well studied; however, no previous study has described upper limb movements during gait. However, upper limb movements have an important role during locomotion and can be altered in MS patients due to direct MS lesions or mechanisms of compensation. The aim of this study was to describe the arm movements during gait in a population of MS patients with low disability compared with a healthy control group. In this observational study we analyzed the arm movements during gait in 52 outpatients (mean age: 39.7±9.6years, female: 40%) with relapsing-remitting MS with low disability (mean EDSS: 2±1) and 25 healthy age-matched controls using a 3-dimension gait analysis. MS patients walked slower, with increased mean elbow flexion and decreased amplitude of elbow flexion (ROM) compared to the control group, whereas shoulder and hand movements were similar to controls. These differences were not explained by age or disability. Upper limb alterations in movement during gait in MS patients with low disability can be characterized by an increase in mean elbow flexion and a decrease in amplitude (ROM) for elbow flexion/extension. This upper limb movement pattern should be considered as a new component of gait disorders in MS and may reflect subtle motor deficits or the use of compensatory mechanisms. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Gait Analysis in Rats with Single Joint Inflammation: Influence of Experimental Factors

    PubMed Central

    Ängeby Möller, Kristina; Kinert, Susanne; Størkson, Rolf; Berge, Odd-Geir

    2012-01-01

    Disability and movement-related pain are major symptoms of joint disease, motivating the development of methods to quantify motor behaviour in rodent joint pain models. We used observational scoring and automated methods to compare weight bearing during locomotion and during standing after single joint inflammation induced by Freund's complete adjuvant (0.12–8.0 mg/mL) or carrageenan (0.47–30 mg/mL). Automated gait analysis was based on video capture of prints generated by light projected into the long edge of the floor of a walkway, producing an illuminated image of the contact area of each paw with light intensity reflecting the contact pressure. Weight bearing was calculated as an area-integrated paw pressure, that is, the light intensity of all pixels activated during the contact phase of a paw placement. Automated static weight bearing was measured with the Incapacitance tester. Pharmacological sensitivity of weight-bearing during locomotion was tested in carrageenan-induced monoarthritis by administration of the commonly used analgesics diclofenac, ibuprofen, and naproxen, as well as oxycodone and paracetamol. Observational scoring and automated quantification yielded similar results. We found that the window between control rats and monoarthritic rats was greater during locomotion. The response was more pronounced for inflammation in the ankle as compared to the knee, suggesting a methodological advantage of using this injection site. The effects of both Freund's complete adjuvant and carrageenan were concentration related, but Freund's incomplete adjuvant was found to be as effective as lower, commonly used concentrations of the complete adjuvant. The results show that gait analysis can be an effective method to quantify behavioural effects of single joint inflammation in the rat, sensitive to analgesic treatment. PMID:23071540

  15. Analysis of gait in rats with olivocerebellar lesions and ability of the nicotinic acetylcholine receptor agonist varenicline to attenuate impairments.

    PubMed

    Lambert, C S; Philpot, R M; Engberg, M E; Johns, B E; Wecker, L

    2015-09-15

    Studies have demonstrated that administration of the neuronal nicotinic receptor agonist varenicline to rats with olivocerebellar lesions attenuates balance deficits on a rotorod and balance beam, but the effects of this drug on gait deficits have not been investigated. To accomplish this, male Sprague-Dawley rats were trained to walk on a motorized treadmill at 25 and 35 cm/s and baseline performance determined; both temporal and spatial gait parameters were analyzed. A principal component analysis (PCA) was used to identify the key components of gait, and the cumulative gait index (CGI) was calculated, representing deviations from prototypical gait patterns. Subsequently, animals either remained as non-lesioned controls or received injections of 3-acetylpyridine (3-AP)/nicotinamide to destroy the climbing fibers innervating Purkinje cells. The gait of the non-lesioned group was assessed weekly to monitor changes in the normal population, while the gait of the lesioned group was assessed 1 week following 3-AP administration, and weekly following the daily administration of saline or varenicline (0.3, 1.0, or 3.0mg free base/kg) for 2 weeks. Non-lesioned animals exhibited a 60-70% increased CGI over time due to increases in temporal gait measures, whereas lesioned animals exhibited a nearly 3-fold increased CGI as a consequence of increases in spatial measures. Following 2 weeks of treatment with the highest dose of varenicline (3.0mg free base/kg), the swing duration of lesioned animals normalized, and stride duration, stride length and step angle in this population did not differ from the non-lesioned population. Thus, varenicline enabled animals to compensate for their impairments and rectify the timing of the gait cycle. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Foot and Ankle Kinematics and Dynamic Electromyography: Quantitative Analysis of Recovery From Peroneal Neuropathy in a Professional Football Player.

    PubMed

    Prasad, Nikhil K; Coleman Wood, Krista A; Spinner, Robert J; Kaufman, Kenton R

    The assessment of neuromuscular recovery after peripheral nerve surgery has typically been a subjective physical examination. The purpose of this report was to assess the value of gait analysis in documenting recovery quantitatively. A professional football player underwent gait analysis before and after surgery for a peroneal intraneural ganglion cyst causing a left-sided foot drop. Surface electromyography (SEMG) recording from surface electrodes and motion parameter acquisition from a computerized motion capture system consisting of 10 infrared cameras were performed simultaneously. A comparison between SEMG recordings before and after surgery showed a progression from disorganized activation in the left tibialis anterior and peroneus longus muscles to temporally appropriate activation for the phase of the gait cycle. Kinematic analysis of ankle motion planes showed resolution from a complete foot drop preoperatively to phase-appropriate dorsiflexion postoperatively. Gait analysis with dynamic SEMG and motion capture complements physical examination when assessing postoperative recovery in athletes.

  17. An Automatic Gait Feature Extraction Method for Identifying Gait Asymmetry Using Wearable Sensors

    PubMed Central

    Vassallo, Michael

    2018-01-01

    This paper aims to assess the use of Inertial Measurement Unit (IMU) sensors to identify gait asymmetry by extracting automatic gait features. We design and develop an android app to collect real time synchronous IMU data from legs. The results from our method are validated using a Qualisys Motion Capture System. The data are collected from 10 young and 10 older subjects. Each performed a trial in a straight corridor comprising 15 strides of normal walking, a turn around and another 15 strides. We analyse the data for total distance, total time, total velocity, stride, step, cadence, step ratio, stance, and swing. The accuracy of detecting the stride number using the proposed method is 100% for young and 92.67% for older subjects. The accuracy of estimating travelled distance using the proposed method for young subjects is 97.73% and 98.82% for right and left legs; and for the older, is 88.71% and 89.88% for right and left legs. The average travelled distance is 37.77 (95% CI ± 3.57) meters for young subjects and is 22.50 (95% CI ± 2.34) meters for older subjects. The average travelled time for young subjects is 51.85 (95% CI ± 3.08) seconds and for older subjects is 84.02 (95% CI ± 9.98) seconds. The results show that wearable sensors can be used for identifying gait asymmetry without the requirement and expense of an elaborate laboratory setup. This can serve as a tool in diagnosing gait abnormalities in individuals and opens the possibilities for home based self-gait asymmetry assessment. PMID:29495299

  18. Improved ankle push-off power following cheilectomy for hallux rigidus: a prospective gait analysis study.

    PubMed

    Smith, Sheryl M; Coleman, Scott C; Bacon, Stacy A; Polo, Fabian E; Brodsky, James W

    2012-06-01

    There is limited objective scientific information on the functional effects of cheilectomy. The purpose of this study was to test the hypothesis that cheilectomy for hallux rigidus improves gait by increasing ankle push-off power. Seventeen patients with symptomatic Stage 1 or Stage 2 hallux rigidus were studied. Pre- and postoperative first metatarsophalangeal (MTP) range of motion and AOFAS hallux scores were recorded. A gait analysis was performed within 4 weeks prior to surgery and repeated at a minimum of 1 year after surgery. Gait analysis was done using a three-dimensional motion capture system and a force platform embedded in a 10-m walkway. Gait velocity sagittal plane ankle range of motion and peak sagittal plane ankle push-off power were analyzed. Following cheilectomy, significant increases were noted for first MTP range of motion and AOFAS hallux score. First MTP motion improved an average of 16.7 degrees, from means of 33.9 degrees preoperatively to 50.6 degrees postoperatively (p<0.001). AOFAS hallux score increased from 62 to 81 (p<0.007). As demonstrated through gait anaylsis, a significant increase in postoperative peak sagittal plane ankle push-off power from 1.71±0.92 W/kg to 2.05±0.75 W/kg (p<0.04). In addition to clinically increased range of motion and improved AOFAS Hallux score, first MTP joint cheilectomy produced objective improvement in gait, as measured by increased peak sagittal-plane ankle push-off power.

  19. The developmental dynamics of gait maturation with a focus on spatiotemporal measures.

    PubMed

    Kraan, C M; Tan, A H J; Cornish, K M

    2017-01-01

    Gait analysis is recognised as a powerful clinical tool for studying relationships between motor control and brain function. By drawing on the literature investigating gait in individuals with neurological disorders, this review provides insight into the neural processes that contribute to and regulate specific spatiotemporal sub-components of gait and how they may mature across early to late childhood. This review also discusses the roles of changing anthropomorphic characteristics, and maturing sensory and higher-order cognitive processes in differentiating the developmental trajectories of the sub-components of gait. Importantly, although studies have shown that cognitive-gait interference is larger in children compared to adults, the contributing neurocognitive mechanisms may vary across age groups who have different types of attentional or cognitive vulnerabilities. These findings have implications for current models of gait maturation by highlighting the need for a dynamic model that focuses on the integration of various factors that contribute to gait though experience and practice. This is essential to elucidating why gait and other motor deficits are often contiguous with cognitive neurodevelopmental disorders. Copyright © 2016. Published by Elsevier B.V.

  20. DMRT3 is associated with gait type in Mangalarga Marchador horses, but does not control gait ability.

    PubMed

    Patterson, L; Staiger, E A; Brooks, S A

    2015-04-01

    The Mangalarga Marchador (MM) is a Brazilian horse breed known for a uniquely smooth gait. A recent publication described a mutation in the DMRT3 gene that the authors claim controls the ability to perform lateral patterned gaits (Andersson et al. 2012). We tested 81 MM samples for the DMRT3 mutation using extracted DNA from hair bulbs using a novel RFLP. Horses were phenotypically categorized by their gait type (batida or picada), as recorded by the Brazilian Mangalarga Marchador Breeders Association (ABCCMM). Statistical analysis using the plink toolset (Purcell, 2007) revealed significant association between gait type and the DMRT3 mutation (P = 2.3e-22). Deviation from Hardy-Weinberg equilibrium suggests that selective pressure for gait type is altering allele frequencies in this breed (P = 1.00e-5). These results indicate that this polymorphism may be useful for genotype-assisted selection for gait type within this breed. As both batida and picada MM horses can perform lateral gaits, the DMRT3 mutation is not the only locus responsible for the lateral gait pattern. © 2015 Stichting International Foundation for Animal Genetics.

  1. Quantifying Variation in Gait Features from Wearable Inertial Sensors Using Mixed Effects Models

    PubMed Central

    Cresswell, Kellen Garrison; Shin, Yongyun; Chen, Shanshan

    2017-01-01

    The emerging technology of wearable inertial sensors has shown its advantages in collecting continuous longitudinal gait data outside laboratories. This freedom also presents challenges in collecting high-fidelity gait data. In the free-living environment, without constant supervision from researchers, sensor-based gait features are susceptible to variation from confounding factors such as gait speed and mounting uncertainty, which are challenging to control or estimate. This paper is one of the first attempts in the field to tackle such challenges using statistical modeling. By accepting the uncertainties and variation associated with wearable sensor-based gait data, we shift our efforts from detecting and correcting those variations to modeling them statistically. From gait data collected on one healthy, non-elderly subject during 48 full-factorial trials, we identified four major sources of variation, and quantified their impact on one gait outcome—range per cycle—using a random effects model and a fixed effects model. The methodology developed in this paper lays the groundwork for a statistical framework to account for sources of variation in wearable gait data, thus facilitating informative statistical inference for free-living gait analysis. PMID:28245602

  2. Estimation of spatial-temporal gait parameters using a low-cost ultrasonic motion analysis system.

    PubMed

    Qi, Yongbin; Soh, Cheong Boon; Gunawan, Erry; Low, Kay-Soon; Thomas, Rijil

    2014-08-20

    In this paper, a low-cost motion analysis system using a wireless ultrasonic sensor network is proposed and investigated. A methodology has been developed to extract spatial-temporal gait parameters including stride length, stride duration, stride velocity, stride cadence, and stride symmetry from 3D foot displacements estimated by the combination of spherical positioning technique and unscented Kalman filter. The performance of this system is validated against a camera-based system in the laboratory with 10 healthy volunteers. Numerical results show the feasibility of the proposed system with average error of 2.7% for all the estimated gait parameters. The influence of walking speed on the measurement accuracy of proposed system is also evaluated. Statistical analysis demonstrates its capability of being used as a gait assessment tool for some medical applications.

  3. Effects of Rhythmic Auditory Cueing in Gait Rehabilitation for Multiple Sclerosis: A Mini Systematic Review and Meta-Analysis

    PubMed Central

    Ghai, Shashank; Ghai, Ishan

    2018-01-01

    Rhythmic auditory cueing has been shown to enhance gait performance in several movement disorders. The “entrainment effect” generated by the stimulations can enhance auditory motor coupling and instigate plasticity. However, a consensus as to its influence over gait training among patients with multiple sclerosis is still warranted. A systematic review and meta-analysis was carried out to analyze the effects of rhythmic auditory cueing in studies gait performance in patients with multiple sclerosis. This systematic identification of published literature was performed according to PRISMA guidelines, from inception until Dec 2017, on online databases: Web of science, PEDro, EBSCO, MEDLINE, Cochrane, EMBASE, and PROQUEST. Studies were critically appraised using PEDro scale. Of 602 records, five studies (PEDro score: 5.7 ± 1.3) involving 188 participants (144 females/40 males) met our inclusion criteria. The meta-analysis revealed enhancements in spatiotemporal parameters of gait i.e., velocity (Hedge's g: 0.67), stride length (0.70), and cadence (1.0), and reduction in timed 25 feet walking test (−0.17). Underlying neurophysiological mechanisms, and clinical implications are discussed. This present review bridges the gaps in literature by suggesting application of rhythmic auditory cueing in conventional rehabilitation approaches to enhance gait performance in the multiple sclerosis community. PMID:29942278

  4. The effect of subtalar inversion/eversion on the dynamic function of the tibialis anterior, soleus, and gastrocnemius during the stance phase of gait.

    PubMed

    Wang, Ruoli; Gutierrez-Farewik, Elena M

    2011-05-01

    The purpose of this study was to determine how gait deviation in one plane (i.e. excessive subtalar inversion/eversion) can affect the dynamic function of the tibialis anterior, gastrocnemius, and soleus to accelerate the subtalar, ankle, knee and hip joints, as well as the body center of mass. Induced acceleration analysis was performed based on a subject-specific three-dimensional linkage model configured by stance phase gait data and driven by one unit of muscle force. Eight healthy adult subjects were examined in gait analysis. The subtalar inversion/eversion was modeled by offsetting up to 20° from the normal subtalar angle while other configurations remained unaltered. This study showed that the gastrocnemius, soleus and tibialis anterior generally functioned as their anatomical definition in normal gait, but counterintuitive function was occasionally found in the bi-articular gastrocnemius. The plantarflexors play important roles in the body support and forward progression. Excessive subtalar eversion was found to enlarge the plantarflexors and tibialis anterior's function. Induced acceleration analysis demonstrated its ability to isolate the contributions of individual muscle to a given factor, and as a means of studying effect of pathological gait on the dynamic muscle functions. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. The effect of pharmacological treatment on gait biomechanics in peripheral arterial disease patients

    PubMed Central

    2010-01-01

    Background Pharmacological treatment has been advocated as a first line therapy for Peripheral Arterial Disease (PAD) patients suffering from intermittent claudication. Previous studies document the ability of pharmacological treatment to increase walking distances. However, the effect of pharmacological treatment on gait biomechanics in PAD patients has not been objectively evaluated as is common with other gait abnormalities. Methods Sixteen patients were prescribed an FDA approved drug (Pentoxifylline or Cilostazol) for the treatment of symptomatic PAD. Patients underwent baseline gait testing prior to medication use which consisted of acquisition of ground reaction forces and kinematics while walking in a pain free state. After three months of treatment, patients underwent repeat gait testing. Results Patients with symptomatic PAD had significant gait abnormalities at baseline during pain free walking as compared to healthy controls. However, pharmacological treatment did not produce any identifiable alterations on the biomechanics of gait of the PAD patients as revealed by the statistical comparisons performed between pre and post-treatment and between post-treatment and the healthy controls. Conclusions Pharmacological treatment did not result in statistically significant improvements in the gait biomechanics of patients with symptomatic PAD. Future studies will need to further explore different cohorts of patients that have shown to improve significantly their claudication distances and/or their muscle fiber morphology with the use of pharmacological treatment and determine if this is associated with an improvement in gait biomechanics. Using these methods we may distinguish the patients who benefit from pharmacotherapy and those who do not. PMID:20529284

  6. Measuring Clearance Mechanics Based on Dynamic Leg Length

    ERIC Educational Resources Information Center

    Khamis, Sam; Danino, Barry; Hayek, Shlomo; Carmeli, Eli

    2018-01-01

    The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant…

  7. Gait analysis in demented subjects: Interests and perspectives

    PubMed Central

    Beauchet, Olivier; Allali, Gilles; Berrut, Gilles; Hommet, Caroline; Dubost, Véronique; Assal, Frédéric

    2008-01-01

    Gait disorders are more prevalent in dementia than in normal aging and are related to the severity of cognitive decline. Dementia-related gait changes (DRGC) mainly include decrease in walking speed provoked by a decrease in stride length and an increase in support phase. More recently, dual-task related changes in gait were found in Alzheimer’s disease (AD) and non-Alzheimer dementia, even at an early stage. An increase in stride-to-stride variability while usual walking and dual-tasking has been shown to be more specific and sensitive than any change in mean value in subjects with dementia. Those data show that DRGC are not only associated to motor disorders but also to problem with central processing of information and highlight that dysfunction of temporal and frontal lobe may in part explain gait impairment among demented subjects. Gait assessment, and more particularly dual-task analysis, is therefore crucial in early diagnosis of dementia and/or related syndromes in the elderly. Moreover, dual-task disturbances could be a specific marker of falling at a pre-dementia stage. PMID:18728766

  8. Reliability and validity of Edinburgh visual gait score as an evaluation tool for children with cerebral palsy.

    PubMed

    Del Pilar Duque Orozco, Maria; Abousamra, Oussama; Church, Chris; Lennon, Nancy; Henley, John; Rogers, Kenneth J; Sees, Julieanne P; Connor, Justin; Miller, Freeman

    2016-09-01

    Assessment of gait abnormalities in cerebral palsy (CP) is challenging, and access to instrumented gait analysis is not always feasible. Therefore, many observational gait analysis scales have been devised. This study aimed to evaluate the interobserver reliability, intraobserver reliability, and validity of Edinburgh visual gait score (EVGS). Video of 30 children with spastic CP were reviewed by 7 raters (10 children each in GMFCS levels I, II, and III, age 6-12 years). Three observers had high level of experience in gait analysis (10+ years), two had medium level (2-5 years) and two had no previous experience (orthopedic fellows). Interobserver reliability was evaluated using percentage of complete agreement and kappa values. Criterion validity was evaluated by comparing EVGS scores with 3DGA data taken from the same video visit. Interobserver agreement was 60-90% and Kappa values were 0.18-0.85 for the 17 items in EVGS. Reliability was higher for distal segments (foot/ankle/knee 63-90%; trunk/pelvis/hip 60-76%), with greater experience (high 66-91%, medium 62-90%, no-experience 41-87%), with more EVGS practice (1st 10 videos 52-88%, last 10 videos 64-97%) and when used with higher functioning children (GMFCS I 65-96%, II 58-90%, III 35-65%). Intraobserver agreement was 64-92%. Agreement between EVGS and 3DGA was 52-73%. We believe that having EVGS as part of the standardized gait evaluation is helpful in optimizing the visual scoring. EVGS can be a supportive tool that adds quantitative data instead of only qualitative assessment to a video only gait evaluation. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Development of a universal measure of quadrupedal forelimb-hindlimb coordination using digital motion capture and computerised analysis.

    PubMed

    Hamilton, Lindsay; Franklin, Robin J M; Jeffery, Nick D

    2007-09-18

    Clinical spinal cord injury in domestic dogs provides a model population in which to test the efficacy of putative therapeutic interventions for human spinal cord injury. To achieve this potential a robust method of functional analysis is required so that statistical comparison of numerical data derived from treated and control animals can be achieved. In this study we describe the use of digital motion capture equipment combined with mathematical analysis to derive a simple quantitative parameter - 'the mean diagonal coupling interval' - to describe coordination between forelimb and hindlimb movement. In normal dogs this parameter is independent of size, conformation, speed of walking or gait pattern. We show here that mean diagonal coupling interval is highly sensitive to alterations in forelimb-hindlimb coordination in dogs that have suffered spinal cord injury, and can be accurately quantified, but is unaffected by orthopaedic perturbations of gait. Mean diagonal coupling interval is an easily derived, highly robust measurement that provides an ideal method to compare the functional effect of therapeutic interventions after spinal cord injury in quadrupeds.

  10. Kinematic Gait Changes Following Serial Casting and Bracing to Treat Toe Walking in a Child With Autism.

    PubMed

    Barkocy, Marybeth; Dexter, James; Petranovich, Colleen

    2017-07-01

    To evaluate the effectiveness of serial casting in a child with autism spectrum disorder (ASD) exhibiting a toe-walking gait pattern with equinus contractures. Although many children with ASD toe walk, little research on physical therapy interventions exists for this population. Serial casting has been validated for use in idiopathic toe walking to increase passive dorsiflexion and improve gait, but not for toe walking in children with ASD. Serial casting followed by ankle-foot orthosis use was implemented to treat a child with ASD who had an obligatory equinus gait pattern. Gait analysis supported improvements in kinematic, spatial, and temporal parameters of gait, and the child maintained a consistent heel-toe gait at 2-year follow-up. STATEMENT OF CONCLUSION AND RECOMMENDATIONS FOR CLINICAL PRACTICE:: Serial casting followed by ankle-foot orthosis use is a viable treatment option for toe walking in children with ASD.

  11. Increased Anterior Pelvic Angle Characterizes the Gait of Children with Attention Deficit/Hyperactivity Disorder (ADHD).

    PubMed

    Naruse, Hiroaki; Fujisawa, Takashi X; Yatsuga, Chiho; Kubota, Masafumi; Matsuo, Hideaki; Takiguchi, Shinichiro; Shimada, Seiichiro; Imai, Yuto; Hiratani, Michio; Kosaka, Hirotaka; Tomoda, Akemi

    2017-01-01

    Children with attention deficit/hyperactivity disorder (ADHD) frequently have motor problems. Previous studies have reported that the characteristic gait in children with ADHD is immature and that subjects demonstrate higher levels of variability in gait characteristics for the lower extremities than healthy controls. However, little is known about body movement during gait in children with ADHD. The purpose of this study was to identify the characteristic body movements associated with ADHD symptoms in children with ADHD. Using a three-dimensional motion analysis system, we compared gait variables in boys with ADHD (n = 19; mean age, 9.58 years) and boys with typical development (TD) (n = 21; mean age, 10.71 years) to determine the specific gait characteristics related to ADHD symptoms. We assessed spatiotemporal gait variables (i.e. speed, stride length, and cadence), and kinematic gait variables (i.e. angle of pelvis, hip, knee, and ankle) to measure body movement when walking at a self-selected pace. In comparison with the TD group, the ADHD group demonstrated significantly higher values in cadence (t = 3.33, p = 0.002) and anterior pelvic angle (t = 3.08, p = 0.004). In multiple regression analysis, anterior pelvic angle was associated with the ADHD rating scale hyperactive/impulsive scores (β = 0.62, t = 2.58, p = 0.025), but not other psychiatric symptoms in the ADHD group. Our results suggest that anterior pelvic angle represents a specific gait variable related to ADHD symptoms. Our kinematic findings could have potential implications for evaluating the body movement in boys with ADHD.

  12. Gait analysis in patients with chronic obstructive pulmonary disease: a systematic review.

    PubMed

    Zago, Matteo; Sforza, Chiarella; Bonardi, Daniela Rita; Guffanti, Enrico Eugenio; Galli, Manuela

    2018-03-01

    Gait instability is a major fall-risk factor in patients with chronic obstructive pulmonary disease (COPD). Clinical gait analysis is a reliable tool to predict fall onsets. However, controversy still exists on gait impairments associated with COPD. Thus, the aims of this review were to evaluate the current understanding of spatiotemporal, kinematic and kinetic gait features in patients with COPD. In line with PRISMA guidelines, a systematic literature search was performed throughout Web of Science, PubMed Medline, Scopus, PEDro and Scielo databases. We considered observational cross-sectional studies evaluating gait features in patients with COPD as their primary outcome. Risk of bias and applicability of these papers were assessed according to the QUADAS-2 tool. Seven articles, cross-sectional studies published from 2011 to 2017, met the inclusion criteria. Sample size of patients with COPD ranged 14-196 (mean age range: 64-75 years). The main reported gait abnormalities were reduced step length and cadence, and altered variability of spatiotemporal parameters. Only subtle biomechanical changes were reported at the ankle level. A convincing mechanistic link between such gait impairments and falls in patients with COPD is still lacking. The paucity of studies, small sample sizes, gender and disease status pooling were the main risk of biases affecting the results uncertainty. Two research directions emerged: stricter cohorts characterization in terms of COPD phenotype and longitudinal studies. Quantitative assessment of gait would identify abnormalities and sensorimotor postural deficiencies that in turn may lead to better falling prevention strategies in COPD. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Clinical gait evaluation of patients with knee osteoarthritis.

    PubMed

    Sun, Jun; Liu, Yancheng; Yan, Songhua; Cao, Guanglei; Wang, Shasha; Lester, D Kevin; Zhang, Kuan

    2017-10-01

    Knee osteoarthritis (KOA) is the most common osteoarthritis in lower limbs, and gait measurement is important to evaluate walking function of KOA patients before and after treatment. The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3) is a portable gait analysis system to evaluate gaits. This study is to evaluate the accuracy and reliability of IDEEA3 for gait measurement of KOA patients. Meanwhile, gait differences between KOA patients and healthy subjects are examined. Twelve healthy volunteers were recruited for measurement comparison of gait cycle (GC), cadence, step length, velocity and step counts between a motion analysis system and a high-speed camera (GoPro Hero3). Twenty-three KOA patients were recruited for measurement comparison of former five parameters between GoPro Hero3 and IDEEA3. Paired t-test, Concordance Correlation Coefficient (CCC) and Intraclass Correlation Coefficient (ICC) were used for data analysis. All p-values of paired t-tests for GC, cadence, step length and velocity were greater than 0.05 while all CCC and ICC results were above 0.95. The measurements of GC, cadence, step length, velocity and step counts by motion analysis system are highly consistent with the measurements by GoPro Hero3. The measurements of former parameters by GoPro Hero3 are not statistically different from the measurements by IDEEA3. IDEEA3 can be effectively used for the measurement of GC, cadence, step length, velocity and step counts in KOA patients. The KOA patients walk with longer GC, lower cadence, shorter step length and slower speed compared with healthy subjects in natural speed with flat shoes. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Hamstring Activity in the Anterior Cruciate Ligament Injured Patient: Injury Implications and Comparison With Quadriceps Activity.

    PubMed

    Frank, Rachel M; Lundberg, Hannah; Wimmer, Markus A; Forsythe, Brian; Bach, Bernard R; Verma, Nikhil N; Cole, Brian J

    2016-08-01

    To investigate the potential causes of diminished knee extension after acute anterior cruciate ligament (ACL) injury using both surface electromyography (sEMG) analysis of the quadriceps and hamstrings, and gait analysis to assess muscle action and tone. Consecutive patients with an acute ACL tear underwent sEMG and gait analysis within 2 weeks of injury, before ACL reconstruction. Standard motion analysis techniques were used and sEMG data were collected simultaneously with gait data. T-tests were used to determine differences between the ACL-deficient and control subjects in knee flexion angles, peak external knee joint moments, and total time that a muscle was activated ("on") during gait. External knee moments were expressed as a percentage of body weight times height. Ten patients (mean age 24 ± 4 years) were included at a mean 10.2 days between injury and analysis; 10 uninjured, matched control subjects were included for comparison. There were significant increases in minimum flexion angle at heel strike (5.92 ± 3.39 v -3.49 ± 4.55, P < .001) and midstance (14.1 ± 6.23 v 1.20 ± 4.21, P < .001) in the injured limb compared with controls. There were significantly lower maximum external extension moments at heel strike (-0.99 ± 0.46 v -2.94 ± 0.60, P < .001) and during the second half of stance in the injured limb compared with controls (-0.56 ± 1.14 v -3.54 ± 1.31, P < .001). The rectus femoris was "on" significantly less during gait in the injured leg compared with controls (49.1 ± 7.76% v 61.0 ± 14.8%, P = .044). There were no significant differences in hamstring activity "on" time during gait (P > .05). In patients with acute ACL injury, the ACL-deficient limb does not reach as much extension as controls. Although the rectus femoris is "on" for shorter periods during the gait cycle, there is no difference in hamstring time on during gait. This information may help clinicians better understand muscle function and gait patterns in the acute time period after ACL injury. Level III, case control study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Prevalence and Burden of Gait Disorders in Elderly Men and Women Aged 60–97 Years: A Population-Based Study

    PubMed Central

    Mahlknecht, Philipp; Kiechl, Stefan; Bloem, Bastiaan R.; Willeit, Johann; Scherfler, Christoph; Gasperi, Arno; Rungger, Gregorio; Poewe, Werner; Seppi, Klaus

    2013-01-01

    Background Although gait disorders are common in the elderly, the prevalence and overall burden of these disorders in the general community is not well defined. Methods In a cross-sectional investigation of the population-based Bruneck Study cohort, 488 community-residing elderly aged 60–97 years underwent a thorough neurological assessment including a standardized gait evaluation. Gait disorders were classified according to an accepted scheme and their associations to falls, neuropsychological measures, and quality of life were explored. Results Overall, 32.2% (95% confidence interval [CI] 28.2%–36.4%) of participants presented with impaired gait. Prevalence increased with age (p<0.001), but 38.3% (95%CI 30.1%–47.3%) of the subjects aged 80 years or older still had a normally preserved gait. A total of 24.0% (95%CI 20.4%–28.0%) manifested neurological gait disorders, 17.4% (14.3%–21.0%) non-neurological gait problems, and 9.2% (6.9%–12.1%) a combination of both. While there was no association of neurological gait disorders with gender, non-neurological gait disorders were more frequent in women (p = 0.012). Within the group of neurological gait disorders 69.2% (95%CI 60.3%–76.9%) had a single distinct entity and 30.8% (23.1%–39.7%) had multiple neurological causes for gait impairment. Gait disorders had a significant negative impact on quantitative gait measures, but only neurological gait disorders were associated with recurrent falls (odds ratio 3.3; 95%CI 1.4–7.5; p = 0.005 for single and 7.1; 2.7–18.7; p<0.001 for multiple neurological gait disorders). Finally, we detected a significant association of gait disorders, in particular neurological gait disorders, with depressed mood, cognitive dysfunction, and compromised quality of life. Conclusions Gait disorders are common in the general elderly population and are associated with reduced mobility. Neurological gait disorders in particular are associated with recurrent falls, lower cognitive function, depressed mood, and diminished quality of life. PMID:23894511

  16. Simple analytical model reveals the functional role of embodied sensorimotor interaction in hexapod gaits

    PubMed Central

    Aoi, Shinya; Nachstedt, Timo; Manoonpong, Poramate; Wörgötter, Florentin; Matsuno, Fumitoshi

    2018-01-01

    Insects have various gaits with specific characteristics and can change their gaits smoothly in accordance with their speed. These gaits emerge from the embodied sensorimotor interactions that occur between the insect’s neural control and body dynamic systems through sensory feedback. Sensory feedback plays a critical role in coordinated movements such as locomotion, particularly in stick insects. While many previously developed insect models can generate different insect gaits, the functional role of embodied sensorimotor interactions in the interlimb coordination of insects remains unclear because of their complexity. In this study, we propose a simple physical model that is amenable to mathematical analysis to explain the functional role of these interactions clearly. We focus on a foot contact sensory feedback called phase resetting, which regulates leg retraction timing based on touchdown information. First, we used a hexapod robot to determine whether the distributed decoupled oscillators used for legs with the sensory feedback generate insect-like gaits through embodied sensorimotor interactions. The robot generated two different gaits and one had similar characteristics to insect gaits. Next, we proposed the simple model as a minimal model that allowed us to analyze and explain the gait mechanism through the embodied sensorimotor interactions. The simple model consists of a rigid body with massless springs acting as legs, where the legs are controlled using oscillator phases with phase resetting, and the governed equations are reduced such that they can be explained using only the oscillator phases with some approximations. This simplicity leads to analytical solutions for the hexapod gaits via perturbation analysis, despite the complexity of the embodied sensorimotor interactions. This is the first study to provide an analytical model for insect gaits under these interaction conditions. Our results clarified how this specific foot contact sensory feedback contributes to generation of insect-like ipsilateral interlimb coordination during hexapod locomotion. PMID:29489831

  17. Comparative assessment of bone pose estimation using Point Cluster Technique and OpenSim.

    PubMed

    Lathrop, Rebecca L; Chaudhari, Ajit M W; Siston, Robert A

    2011-11-01

    Estimating the position of the bones from optical motion capture data is a challenge associated with human movement analysis. Bone pose estimation techniques such as the Point Cluster Technique (PCT) and simulations of movement through software packages such as OpenSim are used to minimize soft tissue artifact and estimate skeletal position; however, using different methods for analysis may produce differing kinematic results which could lead to differences in clinical interpretation such as a misclassification of normal or pathological gait. This study evaluated the differences present in knee joint kinematics as a result of calculating joint angles using various techniques. We calculated knee joint kinematics from experimental gait data using the standard PCT, the least squares approach in OpenSim applied to experimental marker data, and the least squares approach in OpenSim applied to the results of the PCT algorithm. Maximum and resultant RMS differences in knee angles were calculated between all techniques. We observed differences in flexion/extension, varus/valgus, and internal/external rotation angles between all approaches. The largest differences were between the PCT results and all results calculated using OpenSim. The RMS differences averaged nearly 5° for flexion/extension angles with maximum differences exceeding 15°. Average RMS differences were relatively small (< 1.08°) between results calculated within OpenSim, suggesting that the choice of marker weighting is not critical to the results of the least squares inverse kinematics calculations. The largest difference between techniques appeared to be a constant offset between the PCT and all OpenSim results, which may be due to differences in the definition of anatomical reference frames, scaling of musculoskeletal models, and/or placement of virtual markers within OpenSim. Different methods for data analysis can produce largely different kinematic results, which could lead to the misclassification of normal or pathological gait. Improved techniques to allow non-uniform scaling of generic models to more accurately reflect subject-specific bone geometries and anatomical reference frames may reduce differences between bone pose estimation techniques and allow for comparison across gait analysis platforms.

  18. A biofeedback cycling training to improve locomotion: a case series study based on gait pattern classification of 153 chronic stroke patients.

    PubMed

    Ferrante, Simona; Ambrosini, Emilia; Ravelli, Paola; Guanziroli, Eleonora; Molteni, Franco; Ferrigno, Giancarlo; Pedrocchi, Alessandra

    2011-08-24

    The restoration of walking ability is the main goal of post-stroke lower limb rehabilitation and different studies suggest that pedaling may have a positive effect on locomotion. The aim of this study was to explore the feasibility of a biofeedback pedaling treatment and its effects on cycling and walking ability in chronic stroke patients. A case series study was designed and participants were recruited based on a gait pattern classification of a population of 153 chronic stroke patients. In order to optimize participants selection, a k-means cluster analysis was performed to subgroup homogenous gait patterns in terms of gait speed and symmetry.The training consisted of a 2-week treatment of 6 sessions. A visual biofeedback helped the subjects in maintaining a symmetrical contribution of the two legs during pedaling. Participants were assessed before, after training and at follow-up visits (one week after treatment). Outcome measures were the unbalance during a pedaling test, and the temporal, spatial, and symmetry parameters during gait analysis. Three clusters, mainly differing in terms of gait speed, were identified and participants, representative of each cluster, were selected.An intra-subject statistical analysis (ANOVA) showed that all patients significantly decreased the pedaling unbalance after treatment and maintained significant improvements with respect to baseline at follow-up. The 2-week treatment induced some modifications in the gait pattern of two patients: one, the most impaired, significantly improved mean velocity and increased gait symmetry; the other one reduced significantly the over-compensation of the healthy limb. No benefits were produced in the gait of the last subject who maintained her slow but almost symmetrical pattern. Thus, this study might suggest that the treatment can be beneficial for patients having a very asymmetrical and inefficient gait and for those that overuse the healthy leg. The results demonstrated that the treatment is feasible and it might be effective in translating progresses from pedaling to locomotion. If these results are confirmed on a larger and controlled scale, the intervention, thanks to its safety and low price, could have a significant impact as a home- rehabilitation treatment for chronic stroke patients.

  19. Walking Stroop carpet: an innovative dual-task concept for detecting cognitive impairment

    PubMed Central

    Perrochon, A; Kemoun, G; Watelain, E; Berthoz, A

    2013-01-01

    Background Several studies have reported the potential value of the dual-task concept during locomotion in clinical evaluation because cognitive decline is strongly associated with gait abnormalities. However, current dual-task tests appear to be insufficient for early diagnosis of cognitive impairment. Methods Forty-nine subjects (young, old, with or without mild cognitive impairment) underwent cognitive evaluation (Mini-Mental State Examination, Frontal Assessment Battery, five-word test, Stroop, clock-drawing) and single-task locomotor evaluation on an electronic walkway. They were then dual-task-tested on the Walking Stroop carpet, which is an adaptation of the Stroop color–word task for locomotion. A cluster analysis, followed by an analysis of variance, was performed to assess gait parameters. Results Cluster analysis of gait parameters on the Walking Stroop carpet revealed an interaction between cognitive and functional abilities because it made it possible to distinguish dysexecutive cognitive fragility or decline with a sensitivity of 89% and a specificity of 94%. Locomotor abilities differed according to the group and dual-task conditions. Healthy subjects performed less well on dual-tasking under reading conditions than when they were asked to distinguish colors, whereas dysexecutive subjects had worse motor performances when they were required to dual task. Conclusion The Walking Stroop carpet is a dual-task test that enables early detection of cognitive fragility that has not been revealed by traditional neuropsychological tests or single-task walking analysis. PMID:23682211

  20. Development of an assist controller with robot suit HAL for hemiplegic patients using motion data on the unaffected side.

    PubMed

    Kawamoto, Hiroaki; Kandone, Hideki; Sakurai, Takeru; Ariyasu, Ryohei; Ueno, Yukiko; Eguchi, Kiyoshi; Sankai, Yoshiyuki

    2014-01-01

    Among several characteristics seen in gait of hemiplegic patients after stroke, symmetry is known to be an indicator of the degree of impairment of walking ability. This paper proposes a control method for a wearable type lower limb motion assist robot to realize spontaneous symmetric gait for these individuals. This control method stores the motion of the unaffected limb during swing and then provides motion support on the affected limb during the subsequent swing using the stored pattern to realize symmetric gait based on spontaneous limb swing. This method is implemented on the robot suit HAL (Hybrid Assistive Limbs). Clinical tests were conducted in order to assess the feasibility of the control method. Our case study involved participation of one chronic stroke patient who was not able to flex his right knee. As a result, the walking support for hemiplegic leg provided by the HAL improved the subject's gait symmetry. The feasibility study showed promising basis for the future clinical study.

  1. Concurrent musculoskeletal dynamics and finite element analysis predicts altered gait patterns to reduce foot tissue loading.

    PubMed

    Halloran, Jason P; Ackermann, Marko; Erdemir, Ahmet; van den Bogert, Antonie J

    2010-10-19

    Current computational methods for simulating locomotion have primarily used muscle-driven multibody dynamics, in which neuromuscular control is optimized. Such simulations generally represent joints and soft tissue as simple kinematic or elastic elements for computational efficiency. These assumptions limit application in studies such as ligament injury or osteoarthritis, where local tissue loading must be predicted. Conversely, tissue can be simulated using the finite element method with assumed or measured boundary conditions, but this does not represent the effects of whole body dynamics and neuromuscular control. Coupling the two domains would overcome these limitations and allow prediction of movement strategies guided by tissue stresses. Here we demonstrate this concept in a gait simulation where a musculoskeletal model is coupled to a finite element representation of the foot. Predictive simulations incorporated peak plantar tissue deformation into the objective of the movement optimization, as well as terms to track normative gait data and minimize fatigue. Two optimizations were performed, first without the strain minimization term and second with the term. Convergence to realistic gait patterns was achieved with the second optimization realizing a 44% reduction in peak tissue strain energy density. The study demonstrated that it is possible to alter computationally predicted neuromuscular control to minimize tissue strain while including desired kinematic and muscular behavior. Future work should include experimental validation before application of the methodology to patient care. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Effects of Nordic walking and walking on spatiotemporal gait parameters and ground reaction force.

    PubMed

    Park, Seung Kyu; Yang, Dae Jung; Kang, Yang Hun; Kim, Je Ho; Uhm, Yo Han; Lee, Yong Seon

    2015-09-01

    [Purpose] The purpose of this study was to investigate the effects of Nordic walking and walking on spatiotemporal gait parameters and ground reaction force. [Subjects] The subjects of this study were 30 young adult males, who were divided into a Nordic walking group of 15 subjects and a walking group of 15 subjects. [Methods] To analyze the spatiotemporal parameters and ground reaction force during walking in the two groups, the six-camera Vicon MX motion analysis system was used. The subjects were asked to walk 12 meters using the more comfortable walking method for them between Nordic walking and walking. After they walked 12 meters more than 10 times, their most natural walking patterns were chosen three times and analyzed. To determine the pole for Nordic walking, each subject's height was multiplied by 0.68. We then measured the spatiotemporal gait parameters and ground reaction force. [Results] Compared with the walking group, the Nordic walking group showed an increase in cadence, stride length, and step length, and a decrease in stride time, step time, and vertical ground reaction force. [Conclusion] The results of this study indicate that Nordic walking increases the stride and can be considered as helping patients with diseases affecting their gait. This demonstrates that Nordic walking is more effective in improving functional capabilities by promoting effective energy use and reducing the lower limb load, because the weight of the upper and lower limbs is dispersed during Nordic walking.

  3. Prospective dynamic functional evaluation of gait and spinal balance following spinal fusion in adolescent idiopathic scoliosis.

    PubMed

    Lenke, L G; Engsberg, J R; Ross, S A; Reitenbach, A; Blanke, K; Bridwell, K H

    2001-07-15

    Prospective evaluation of gait and spinal-pelvic balance parameters in patients with adolescent idiopathic scoliosis undergoing a spinal fusion. To evaluate changes in gait and three-dimensional alignment and balance of the spine relative to the pelvis as a consequence of spinal fusion. Preoperative and postoperative spinal radiographs have been the major forms of outcome analysis of adolescent idiopathic scoliosis fusions. The use of optoelectronic analysis for posture and gait has gained acceptance recently. However, there is a paucity of data quantifying, comparing, and correlating structural and functional changes in patients undergoing scoliosis fusion surgery including upright posture and gait. Thirty patients with adolescent idiopathic scoliosis undergoing an instrumented spinal fusion were prospectively evaluated. Coronal and sagittal vertical alignment was evaluated on radiographs (CVA-R, SVA-R), during upright posture (CVA-P and SVA-P), and during gait (CVA-G, SVA-G). Transverse plane alignment was evaluated by the acromion-pelvis angle during gait. Gait speed was significantly decreased (P < 0.05) between preoperative (129 +/- 16 cm/sec) and 2-year postoperative (119 +/- 16 cm/sec) testing sessions. Decreasing gait speed was the result of significantly reduced cadence and decreased stride length. There were no significant differences for lower extremity kinematics over the entire gait cycle. Spinal-pelvic balance parameters showed significant improvement in mean CVA-R, CVA-G (P < 0.05), then unchanged CVA-P at 2 years postoperation. CVA-P was relatively unchanged while the mean CVA-G also showed significant improvement from preoperation (2.2 +/- 2.4 cm) to 2 years postoperation (1.3 +/- 1.3 cm)(P < 0.05). The mean SVA-R, SVA-P, and SVA-G were unchanged at 2 years postoperation (P > 0.05). The acromion-pelvis angle during gait at maximum shoulder rotation was statistically improved at 1 year (P = 0.002) and 2 years (P = 0.001) after surgery. Importantly, CVA-P correlated with CVA-G, and SVA-P correlated with SVA-G to the P < 0.05 level. Patients with adolescent idiopathic scoliosis undergoing spinal fusion show slightly decreased gait speed at 2 years postoperation without any change in lower extremity kinematics. Spinal-pelvic balance parameters are improved in the coronal plane and unchanged in the sagittal plane radiographically and during standing posture and gait. Transverse plane parameters also are improved at maximum shoulder rotation during gait.

  4. Detecting gait alterations due to concussion impairment with radar using information-theoretic techniques

    NASA Astrophysics Data System (ADS)

    Palmer, Jennifer; Bing, Kristin; Sharma, Amy; Greneker, Eugene; Selee, Teresa

    2011-06-01

    Several studies have shown that measuring changes in gait could provide an easier method of diagnosing and monitoring concussions. The purpose of this study was to measure radar signal returns to explore if differences in gait patterns between normal and "concussed" individuals could be identified from radar spectrogram data. Access to concussed individuals was not available during this feasibility study. Instead, based on research that demonstrated concussion impairment is equivalent to a blood alcohol content (BAC) of 0.05%, BAC impairment goggles were used to visually simulate a concussion. Both "impaired" and "not impaired" individuals were asked to complete only a motor skill task (walking) and then complete motor skill and cognitive skill (saying the months of the year in reverse order) tasks simultaneously. Results from the tests were analyzed using informationtheoretic (IT) techniques. IT algorithms were selected because of their potential to identify similarities and differences without having the requirement of a priori knowledge on an individual. To quantify results, two methods were incorporated: decision index, D(Q), analysis with receiver operating characteristic (ROC) curves and object-feature matrix clustering. Both techniques showed acceptable percent correctness in discriminating between normal and "impaired" individuals.

  5. Do Men and Women Walk Differently? A Review and Meta-Analysis of Sex Difference in Non-Pathological Gait Kinematics

    DTIC Science & Technology

    2014-01-01

    Physiotherapy , 2011. 97(3): 182-189. 27. Al-Obaidi, S., et al., Basic gait parameters: a comparison of reference data for normal subjects 20 to 29...et al., Importance of correcting for individual differences in the clinical diagnosis of gait disorders. Physiotherapy , 2012. 98(4): 320-324. 71

  6. Analysis of Parallel and Transverse Visual Cues on the Gait of Individuals with Idiopathic Parkinson's Disease

    ERIC Educational Resources Information Center

    de Melo Roiz, Roberta; Azevedo Cacho, Enio Walker; Cliquet, Alberto, Jr.; Barasnevicius Quagliato, Elizabeth Maria Aparecida

    2011-01-01

    Idiopathic Parkinson's disease (IPD) has been defined as a chronic progressive neurological disorder with characteristics that generate changes in gait pattern. Several studies have reported that appropriate external influences, such as visual or auditory cues may improve the gait pattern of patients with IPD. Therefore, the objective of this…

  7. Using the Oxford Foot Model to determine the association between objective measures of foot function and results of the AOFAS Ankle-Hindfoot Scale and the Foot Function Index: a prospective gait analysis study in Germany.

    PubMed

    Kostuj, Tanja; Stief, Felix; Hartmann, Kirsten Anna; Schaper, Katharina; Arabmotlagh, Mohammad; Baums, Mike H; Meurer, Andrea; Krummenauer, Frank; Lieske, Sebastian

    2018-04-05

    After cross-cultural adaption for the German translation of the Ankle-Hindfoot Scale of the American Orthopaedic Foot and Ankle Society (AOFAS-AHS) and agreement analysis with the Foot Function Index (FFI-D), the following gait analysis study using the Oxford Foot Model (OFM) was carried out to show which of the two scores better correlates with objective gait dysfunction. Results of the AOFAS-AHS and FFI-D, as well as data from three-dimensional gait analysis were collected from 20 patients with mild to severe ankle and hindfoot pathologies.Kinematic and kinetic gait data were correlated with the results of the total AOFAS scale and FFI-D as well as the results of those items representing hindfoot function in the AOFAS-AHS assessment. With respect to the foot disorders in our patients (osteoarthritis and prearthritic conditions), we correlated the total range of motion (ROM) in the ankle and subtalar joints as identified by the OFM with values identified during clinical examination 'translated' into score values. Furthermore, reduced walking speed, reduced step length and reduced maximum ankle power generation during push-off were taken into account and correlated to gait abnormalities described in the scores. An analysis of correlations with CIs between the FFI-D and the AOFAS-AHS items and the gait parameters was performed by means of the Jonckheere-Terpstra test; furthermore, exploratory factor analysis was applied to identify common information structures and thereby redundancy in the FFI-D and the AOFAS-AHS items. Objective findings for hindfoot disorders, namely a reduced ROM, in the ankle and subtalar joints, respectively, as well as reduced ankle power generation during push-off, showed a better correlation with the AOFAS-AHS total score-as well as AOFAS-AHS items representing ROM in the ankle, subtalar joints and gait function-compared with the FFI-D score.Factor analysis, however, could not identify FFI-D items consistently related to these three indicator parameters (pain, disability and function) found in the AOFAS-AHS. Furthermore, factor analysis did not support stratification of the FFI-D into two subscales. The AOFAS-AHS showed a good agreement with objective gait parameters and is therefore better suited to evaluate disability and functional limitations of patients suffering from foot and ankle pathologies compared with the FFI-D. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Swimming with multiple propulsors: measurement and comparison of swimming gaits in three species of neotropical cichlids.

    PubMed

    Feilich, Kara L

    2017-11-15

    Comparative studies of fish swimming have been limited by the lack of quantitative definitions of fish gaits. Traditionally, steady swimming gaits have been defined categorically by the fin or region of the body that is used as the main propulsor and named after major fish clades (e.g. carangiform, anguilliform, balistiform, labriform). This method of categorization is limited by the lack of explicit measurements, the inability to incorporate contributions of multiple propulsors and the inability to compare gaits across different categories. I propose an alternative framework for the definition and comparison of fish gaits based on the propulsive contribution of each structure (body and/or fin) being used as a propulsor relative to locomotor output, and demonstrate the effectiveness of this framework by comparing three species of neotropical cichlids with different body shapes. This approach is modular with respect to the number of propulsors considered, flexible with respect to the definition of the propulsive inputs and the locomotor output of interest, and designed explicitly to handle combinations of propulsors. Using this approach, gait can be defined as a trajectory through propulsive space, and gait transitions can be defined as discontinuities in the gait trajectory. By measuring and defining gait in this way, patterns of clustering corresponding to existing categorical definitions of gait may emerge, and gaits can be rigorously compared across categories. © 2017. Published by The Company of Biologists Ltd.

  9. Bilateral step length estimation using a single inertial measurement unit attached to the pelvis

    PubMed Central

    2012-01-01

    Background The estimation of the spatio-temporal gait parameters is of primary importance in both physical activity monitoring and clinical contexts. A method for estimating step length bilaterally, during level walking, using a single inertial measurement unit (IMU) attached to the pelvis is proposed. In contrast to previous studies, based either on a simplified representation of the human gait mechanics or on a general linear regressive model, the proposed method estimates the step length directly from the integration of the acceleration along the direction of progression. Methods The IMU was placed at pelvis level fixed to the subject's belt on the right side. The method was validated using measurements from a stereo-photogrammetric system as a gold standard on nine subjects walking ten laps along a closed loop track of about 25 m, varying their speed. For each loop, only the IMU data recorded in a 4 m long portion of the track included in the calibrated volume of the SP system, were used for the analysis. The method takes advantage of the cyclic nature of gait and it requires an accurate determination of the foot contact instances. A combination of a Kalman filter and of an optimally filtered direct and reverse integration applied to the IMU signals formed a single novel method (Kalman and Optimally filtered Step length Estimation - KOSE method). A correction of the IMU displacement due to the pelvic rotation occurring in gait was implemented to estimate the step length and the traversed distance. Results The step length was estimated for all subjects with less than 3% error. Traversed distance was assessed with less than 2% error. Conclusions The proposed method provided estimates of step length and traversed distance more accurate than any other method applied to measurements obtained from a single IMU that can be found in the literature. In healthy subjects, it is reasonable to expect that, errors in traversed distance estimation during daily monitoring activity would be of the same order of magnitude of those presented. PMID:22316235

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Qingdu; Guo, Jianli; Yang, Xiao-Song, E-mail: yangxs@hust.edu.cn

    We present some rich new complex gaits in the simple walking model with upper body by Wisse et al. in [Robotica 22, 681 (2004)]. We first show that the stable gait found by Wisse et al. may become chaotic via period-doubling bifurcations. Such period-doubling routes to chaos exist for all parameters, such as foot mass, upper body mass, body length, hip spring stiffness, and slope angle. Then, we report three new gaits with period 3, 4, and 6; for each gait, there is also a period-doubling route to chaos. Finally, we show a practical method for finding a topological horseshoemore » in 3D Poincaré map, and present a rigorous verification of chaos from these gaits.« less

  11. Virtual gait training for children with cerebral palsy using the Lokomat gait orthosis.

    PubMed

    Koenig, Alexander; Wellner, Mathias; Köneke, Susan; Meyer-Heim, Andreas; Lünenburger, Lars; Riener, Robert

    2008-01-01

    The Lokomat gait orthosis was developed in the Spinal Cord Injury Center at the University Hospital Balgrist Zurich and provides automatic gait training for patients with neurological gait impairments, such as Cerebral Palsy (CP). Each patient undergoes a task-oriented Lokomat rehabilitation training program via a virtual reality setup. In four virtual scenarios, the patient is able to exercise tasks such as wading through water, playing soccer, overstepping obstacles or training in a street scenario, each task offering varying levels of difficulty. Patients provided positive feedback in reference to the utilized haptic method, specifically addressing the sufficient degree of realism. In a single case study, we verified the task difficulty.

  12. 3D gait assessment in young and elderly subjects using foot-worn inertial sensors.

    PubMed

    Mariani, Benoit; Hoskovec, Constanze; Rochat, Stephane; Büla, Christophe; Penders, Julien; Aminian, Kamiar

    2010-11-16

    This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Quantitative assessment of the effects of 6 months of adapted physical activity on gait in people with multiple sclerosis: a randomized controlled trial.

    PubMed

    Pau, Massimiliano; Corona, Federica; Coghe, Giancarlo; Marongiu, Elisabetta; Loi, Andrea; Crisafulli, Antonio; Concu, Alberto; Galli, Manuela; Marrosu, Maria Giovanna; Cocco, Eleonora

    2018-01-01

    The purpose of this study is to quantitatively assess the effect of 6 months of supervised adapted physical activity (APA i.e. physical activity designed for people with special needs) on spatio-temporal and kinematic parameters of gait in persons with Multiple Sclerosis (pwMS). Twenty-two pwMS with Expanded Disability Status Scale scores ranging from 1.5 to 5.5 were randomly assigned either to the intervention group (APA, n = 11) or the control group (CG, n = 11). The former underwent 6 months of APA consisting of 3 weekly 60-min sessions of aerobic and strength training, while CG participants were engaged in no structured PA program. Gait patterns were analyzed before and after the training using three-dimensional gait analysis by calculating spatio-temporal parameters and concise indexes of gait kinematics (Gait Profile Score - GPS and Gait Variable Score - GVS) as well as dynamic Range of Motion (ROM) of hip, knee, and ankle joints. The training originated significant improvements in stride length, gait speed and cadence in the APA group, while GPS and GVS scores remained practically unchanged. A trend of improvement was also observed as regard the dynamic ROM of hip, knee, and ankle joints. No significant changes were observed in the CG for any of the parameters considered. The quantitative analysis of gait supplied mixed evidence about the actual impact of 6 months of APA on pwMS. Although some improvements have been observed, the substantial constancy of kinematic patterns of gait suggests that the full transferability of the administered training on the ambulation function may require more specific exercises. Implications for rehabilitation Adapted Physical Activity (APA) is effective in improving spatio-temporal parameters of gait, but not kinematics, in people with multiple sclerosis. Dynamic range of motion during gait is increased after APA. The full transferability of APA on the ambulation function may require specific exercises rather than generic lower limbs strength/flexibility training.

  14. Intensive gait training with rhythmic auditory stimulation in individuals with chronic hemiparetic stroke: a pilot randomized controlled study.

    PubMed

    Cha, Yuri; Kim, Young; Hwang, Sujin; Chung, Yijung

    2014-01-01

    Motor relearning protocols should involve task-oriented movement, focused attention, and repetition of desired movements. To investigate the effect of intensive gait training with rhythmic auditory stimulation on postural control and gait performance in individuals with chronic hemiparetic stroke. Twenty patients with chronic hemiparetic stroke participated in this study. Subjects in the Rhythmic auditory stimulation training group (10 subjects) underwent intensive gait training with rhythmic auditory stimulation for a period of 6 weeks (30 min/day, five days/week), while those in the control group (10 subjects) underwent intensive gait training for the same duration. Two clinical measures, Berg balance scale and stroke specific quality of life scale, and a 2-demensional gait analysis system, were used as outcome measure. To provide rhythmic auditory stimulation during gait training, the MIDI Cuebase musical instrument digital interface program and a KM Player version 3.3 was utilized for this study. Intensive gait training with rhythmic auditory stimulation resulted in significant improvement in scores on the Berg balance scale, gait velocity, cadence, stride length and double support period in affected side, and stroke specific quality of life scale compared with the control group after training. Findings of this study suggest that intensive gait training with rhythmic auditory stimulation improves balance and gait performance as well as quality of life, in individuals with chronic hemiparetic stroke.

  15. Evidence of end-effector based gait machines in gait rehabilitation after CNS lesion.

    PubMed

    Hesse, S; Schattat, N; Mehrholz, J; Werner, C

    2013-01-01

    A task-specific repetitive approach in gait rehabilitation after CNS lesion is well accepted nowadays. To ease the therapists' and patients' physical effort, the past two decades have seen the introduction of gait machines to intensify the amount of gait practice. Two principles have emerged, an exoskeleton- and an endeffector-based approach. Both systems share the harness and the body weight support. With the end-effector-based devices, the patients' feet are positioned on two foot plates, whose movements simulate stance and swing phase. This article provides an overview on the end-effector based machine's effectiveness regarding the restoration of gait. For the electromechanical gait trainer GT I, a meta analysis identified nine controlled trials (RCT) in stroke subjects (n = 568) and were analyzed to detect differences between end-effector-based locomotion + physiotherapy and physiotherapy alone. Patients practising with the machine effected in a superior gait ability (210 out of 319 patients, 65.8% vs. 96 out of 249 patients, 38.6%, respectively, Z = 2.29, p = 0.020), due to a larger training intensity. Only single RCTs have been reported for other devices and etiologies. The introduction of end-effector based gait machines has opened a new succesful chapter in gait rehabilitation after CNS lesion.

  16. Efficacy of ankle control balance training on postural balance and gait ability in community-dwelling older adults: a single-blinded, randomized clinical trial.

    PubMed

    Lee, Kyeongjin; Lee, Yong Woo

    2017-09-01

    [Purpose] This study was conducted to investigate the effects of ankle control balance training (ACBT) on postural balance and gait ability in community-dwelling older adults. [Subjects and Methods] Fifty-four subjects were randomly divided into two groups, with 27 subjects in the ACBT group and 27 subjects in the control group. Subjects in the ACBT group received ACBT for 60 minutes, twice per week for 4 weeks, and all subjects had undergone fall prevention education for 60 minutes, once per week for 4 weeks. The main outcome measures, including the Berg balance scale; the functional reach test and one leg stance test for postural balance; and the timed up-and-go test and 10-meter walking test for gait ability, were assessed at baseline and after 4 weeks of training. [Results] The postural balance and gait ability in the ACBT group improved significantly compared to those in the control group, except BBS. [Conclusion] The results of this study showed improved postural balance and gait abilities after ACBT and that ACBT is a feasible method for improving postural balance and gait ability in community-dwelling older adults.

  17. Efficacy of ankle control balance training on postural balance and gait ability in community-dwelling older adults: a single-blinded, randomized clinical trial

    PubMed Central

    Lee, Kyeongjin; Lee, Yong Woo

    2017-01-01

    [Purpose] This study was conducted to investigate the effects of ankle control balance training (ACBT) on postural balance and gait ability in community-dwelling older adults. [Subjects and Methods] Fifty-four subjects were randomly divided into two groups, with 27 subjects in the ACBT group and 27 subjects in the control group. Subjects in the ACBT group received ACBT for 60 minutes, twice per week for 4 weeks, and all subjects had undergone fall prevention education for 60 minutes, once per week for 4 weeks. The main outcome measures, including the Berg balance scale; the functional reach test and one leg stance test for postural balance; and the timed up-and-go test and 10-meter walking test for gait ability, were assessed at baseline and after 4 weeks of training. [Results] The postural balance and gait ability in the ACBT group improved significantly compared to those in the control group, except BBS. [Conclusion] The results of this study showed improved postural balance and gait abilities after ACBT and that ACBT is a feasible method for improving postural balance and gait ability in community-dwelling older adults. PMID:28931994

  18. Kinematic gait patterns in healthy runners: A hierarchical cluster analysis.

    PubMed

    Phinyomark, Angkoon; Osis, Sean; Hettinga, Blayne A; Ferber, Reed

    2015-11-05

    Previous studies have demonstrated distinct clusters of gait patterns in both healthy and pathological groups, suggesting that different movement strategies may be represented. However, these studies have used discrete time point variables and usually focused on only one specific joint and plane of motion. Therefore, the first purpose of this study was to determine if running gait patterns for healthy subjects could be classified into homogeneous subgroups using three-dimensional kinematic data from the ankle, knee, and hip joints. The second purpose was to identify differences in joint kinematics between these groups. The third purpose was to investigate the practical implications of clustering healthy subjects by comparing these kinematics with runners experiencing patellofemoral pain (PFP). A principal component analysis (PCA) was used to reduce the dimensionality of the entire gait waveform data and then a hierarchical cluster analysis (HCA) determined group sets of similar gait patterns and homogeneous clusters. The results show two distinct running gait patterns were found with the main between-group differences occurring in frontal and sagittal plane knee angles (P<0.001), independent of age, height, weight, and running speed. When these two groups were compared to PFP runners, one cluster exhibited greater while the other exhibited reduced peak knee abduction angles (P<0.05). The variability observed in running patterns across this sample could be the result of different gait strategies. These results suggest care must be taken when selecting samples of subjects in order to investigate the pathomechanics of injured runners. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Gait pattern in myotonic dystrophy (Steinert disease): a kinematic, kinetic and EMG evaluation using 3D gait analysis.

    PubMed

    Galli, Manuela; Cimolin, Veronica; Crugnola, Veronica; Priano, Lorenzo; Menegoni, Francesco; Trotti, Claudio; Milano, Eva; Mauro, Alessandro

    2012-03-15

    We investigated the gait pattern of 10 patients with myotonic dystrophy (Steinert disease; 4 females, 6 males; age: 41.5+7.6 years), compared to 20 healthy controls, through manual muscle test and gait analysis, in terms of kinematic, kinetic and EMG data. In most of patients (80%) distal muscle groups were weaker than proximal ones. Weakness at lower limbs was in general moderate to severe and MRC values evidenced a significant correlation between tibialis anterior and gastrocnemius medialis (R=0.91). An overall observation of gait pattern in patients when compared to controls showed that most spatio-temporal parameters (velocity, step length and cadence) were significantly different. As concerns kinematics, patients' pelvic tilt was globally in a higher position than control group, with reduced hip extension ability in stance phase and limited range of motion; 60% of the limbs revealed knee hyperextension during midstance and ankle joints showed a quite physiological position at initial contact and higher dorsiflexion during stance phase if compared to healthy individuals. Kinetic plots evidenced higher hip power during loading response and lower ankle power generation in terminal stance. The main EMG abnormalities were seen in tibialis anterior and gastrocnemius medialis muscles. In this study gait analysis gives objective and quantitative information about the gait pattern and the deviations due to the muscular situation of these patients; these results are important from a clinical point of view and suggest that rehabilitation programs for them should take these findings into account. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Tools for observational gait analysis in patients with stroke: a systematic review.

    PubMed

    Ferrarello, Francesco; Bianchi, Valeria Anna Maria; Baccini, Marco; Rubbieri, Gaia; Mossello, Enrico; Cavallini, Maria Chiara; Marchionni, Niccolò; Di Bari, Mauro

    2013-12-01

    Stroke severely affects walking ability, and assessment of gait kinematics is important in defining diagnosis, planning treatment, and evaluating interventions in stroke rehabilitation. Although observational gait analysis is the most common approach to evaluate gait kinematics, tools useful for this purpose have received little attention in the scientific literature and have not been thoroughly reviewed. The aims of this systematic review were to identify tools proposed to conduct observational gait analysis in adults with a stroke, to summarize evidence concerning their quality, and to assess their implementation in rehabilitation research and clinical practice. An extensive search was performed of original articles reporting on visual/observational tools developed to investigate gait kinematics in adults with a stroke. Two reviewers independently selected studies, extracted data, assessed quality of the included studies, and scored the metric properties and clinical utility of each tool. Rigor in reporting metric properties and dissemination of the tools also was evaluated. Five tools were identified, not all of which had been tested adequately for their metric properties. Evaluation of content validity was partially satisfactory. Reliability was poorly investigated in all but one tool. Concurrent validity and sensitivity to change were shown for 3 and 2 tools, respectively. Overall, adequate levels of quality were rarely reached. The dissemination of the tools was poor. Based on critical appraisal, the Gait Assessment and Intervention Tool shows a good level of quality, and its use in stroke rehabilitation is recommended. Rigorous studies are needed for the other tools in order to establish their usefulness.

  1. Does robot-assisted gait training ameliorate gait abnormalities in multiple sclerosis? A pilot randomized-control trial.

    PubMed

    Straudi, S; Benedetti, M G; Venturini, E; Manca, M; Foti, C; Basaglia, N

    2013-01-01

    Gait disorders are common in multiple sclerosis (MS) and lead to a progressive reduction of function and quality of life. Test the effects of robot-assisted gait rehabilitation in MS subjects through a pilot randomized-controlled study. We enrolled MS subjects with Expanded Disability Status Scale scores within 4.5-6.5. The experimental group received 12 robot-assisted gait training sessions over 6 weeks. The control group received the same amount of conventional physiotherapy. Outcomes measures were both biomechanical assessment of gait, including kinematics and spatio-temporal parameters, and clinical test of walking endurance (six-minute walk test) and mobility (Up and Go Test). 16 subjects (n = 8 experimental group, n = 8 control group) were included in the final analysis. At baseline the two groups were similar in all variables, except for step length. Data showed walking endurance, as well as spatio-temporal gait parameters improvements after robot-assisted gait training. Pelvic antiversion and reduced hip extension during terminal stance ameliorated after aforementioned intervention. Robot-assisted gait training seems to be effective in increasing walking competency in MS subjects. Moreover, it could be helpful in restoring the kinematic of the hip and pelvis.

  2. The effect of gait velocity on calcaneal balance at heel strike; Implications for orthotic prescription in injury prevention.

    PubMed

    Shanthikumar, Shivanthan; Low, Zi; Falvey, Eanna; McCrory, Paul; Franklyn-Miller, Andy

    2010-01-01

    Exercise related lower limb injuries (ERLLI), are common in the recreational and competitive sporting population. Although ERLLI are thought to be multi-factorial in aetiology, one of the critical predisposing factors is known to gait abnormality. There is little published evidence comparing walking and running gait in the same subjects, and no evidence on the effect of gait velocity on calcaneal pronation, even though this may have implications for orthotic prescription and injury prevention. In this study, the walking and running gait of 50 physically active subjects was assessed using pressure plate analysis. The results show that rearfoot pronation occurs on foot contact in both running and walking gait, and that there is significantly more rearfoot pronation in walking gait (p<0.01). The difference in the magnitude of rearfoot pronation affected foot orthoses prescription. A 63% fall in computerized correction suggested by RSscan D3D software prescription was seen, based on running vs. walking gait. The findings of this study suggest that in the athletic population orthoses prescription should be based on dynamic assessment of running gait. Crown Copyright 2009. Published by Elsevier B.V. All rights reserved.

  3. Artificial Walking Technologies to Improve Gait in Cerebral Palsy: Multichannel Neuromuscular Stimulation.

    PubMed

    Rose, Jessica; Cahill-Rowley, Katelyn; Butler, Erin E

    2017-11-01

    Cerebral palsy (CP) is the most common childhood motor disability and often results in debilitating walking abnormalities, such as flexed-knee and stiff-knee gait. Current medical and surgical treatments are only partially effective in improving gait abnormalities and may cause significant muscle weakness. However, emerging artificial walking technologies, such as step-initiated, multichannel neuromuscular electrical stimulation (NMES), can substantially improve gait patterns and promote muscle strength in children with spastic CP. NMES may also be applied to specific lumbar-sacral sensory roots to reduce spasticity. Development of tablet computer-based multichannel NMES can leverage lightweight, wearable wireless stimulators, advanced control design, and surface electrodes to activate lower-limb muscles. Musculoskeletal models have been used to characterize muscle contributions to unimpaired gait and identify high muscle demands, which can help guide multichannel NMES-assisted gait protocols. In addition, patient-specific NMES-assisted gait protocols based on 3D gait analysis can facilitate the appropriate activation of lower-limb muscles to achieve a more functional gait: stance-phase hip and knee extension and swing-phase sequence of hip and knee flexion followed by rapid knee extension. NMES-assisted gait treatment can be conducted as either clinic-based or home-based programs. Rigorous testing of multichannel NMES-assisted gait training protocols will determine optimal treatment dosage for future clinical trials. Evidence-based outcome evaluation using 3D kinematics or temporal-spatial gait parameters will help determine immediate neuroprosthetic effects and longer term neurotherapeutic effects of step-initiated, multichannel NMES-assisted gait in children with spastic CP. Multichannel NMES is a promising assistive technology to help children with spastic CP achieve a more upright, functional gait. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. Changes of gait pattern in children with Charcot-Marie-Tooth disease type 1A: a 18 months follow-up study

    PubMed Central

    2013-01-01

    Background In a previous study we identified 3 different gait patterns in a group of children with CMT1A disease: Normal-like (NL), Foot-drop (FD), Foot-drop and Push-off Deficit (FD&POD). Goal of the present study was to perform a follow-up evaluation of the same group of patients to analyze possible changes of gait features in relation to disease progression or specific therapy. Methods Nineteen children with CMT1A were evaluated clinically (CMT-Examination Score and Overall Neuropathy Limitation Scale) and through gait analysis 18.2±1.5 months after a baseline evaluation. Meanwhile, 3 of them had foot surgery. Results Fifteen out of the 16 non-operated patients significantly changed at least one of the two parameters associated to primary signs (FD and/or POD). Eleven participants worsened at least one parameter and 9 improved one parameter. CMTES significantly worsened for the group of non-operated patients. However, there was no change in CMTES score in 4 patients and in ONLS score in 11. At subgroup level, participants originally belonging to NL group showed a trend towards a foot-drop deficit (−15%, ns); FD and FD&POD subgroups did not change their primary signs, although significant changes were identified individually. All 3 patients operated have improved push-off and proximal joint patterns during walking. Clinical scores did not change within any sub-group. Conclusions Subtle changes occurring in 1.5 year in gait features of CMT1A children can be instrumentally identified. Such changes show a large inter-subject variability, with some patients even improving their walking pattern. There is anecdotal evidence that foot surgery may improve the push-off phase of gait. PMID:23819439

  5. Meaningful change and responsiveness in common physical performance measures in older adults.

    PubMed

    Perera, Subashan; Mody, Samir H; Woodman, Richard C; Studenski, Stephanie A

    2006-05-01

    To estimate the magnitude of small meaningful and substantial individual change in physical performance measures and evaluate their responsiveness. Secondary data analyses using distribution- and anchor-based methods to determine meaningful change. Secondary analysis of data from an observational study and clinical trials of community-dwelling older people and subacute stroke survivors. Older adults with mobility disabilities in a strength training trial (n=100), subacute stroke survivors in an intervention trial (n=100), and a prospective cohort of community-dwelling older people (n=492). Gait speed, Short Physical Performance Battery (SPPB), 6-minute-walk distance (6MWD), and self-reported mobility. Most small meaningful change estimates ranged from 0.04 to 0.06 m/s for gait speed, 0.27 to 0.55 points for SPPB, and 19 to 22 m for 6MWD. Most substantial change estimates ranged from 0.08 to 0.14 m/s for gait speed, 0.99 to 1.34 points for SPPB, and 47 to 49 m for 6MWD. Based on responsiveness indices, per-group sample sizes for clinical trials ranged from 13 to 42 for substantial change and 71 to 161 for small meaningful change. Best initial estimates of small meaningful change are near 0.05 m/s for gait speed, 0.5 points for SPPB, and 20 m for 6MWD and of substantial change are near 0.10 m/s for gait speed, 1.0 point for SPPB, and 50 m for 6MWD. For clinical use, substantial change in these measures and small change in gait speed and 6MWD, but not SPPB, are detectable. For research use, these measures yield feasible sample sizes for detecting meaningful change.

  6. Net ankle quasi-stiffness is influenced by walking speed but not age for older adult women.

    PubMed

    Collins, John D; Arch, Elisa S; Crenshaw, Jeremy R; Bernhardt, Kathie A; Khosla, Sundeep; Amin, Shreyasee; Kaufman, Kenton R

    2018-03-26

    Insufficient plantar flexor resistance due to plantar flexor weakness, an impairment common in patient populations, causes substantial gait deficits. The bending stiffness of passive-dynamic ankle-foot orthoses (PD-AFOs) has the capacity to replace lost plantar flexor resistance. Many patients who are prescribed PD-AFOs are older adults. While PD-AFO bending stiffness should be customized for patients, a method to objectively prescribe this stiffness does not exist. Quantifying natural plantar flexor resistance during non-pathological gait could provide a reference value for objectively prescribing PD-AFO bending stiffness. This study investigated the effect of age on plantar flexor resistance in 113 participants above the age of 65 years. We did so while also considering the confounding influence of gait speed, an aspect known to be reduced with old age. Ambulatory, community-dwelling older adult women (ages 65-91 years) with no current or recent lower-extremity injuries or surgeries underwent an instrumented gait analysis at a self-selected speed. Plantar flexor resistance was quantified via net ankle quasi-stiffness (NAS) defined as the slope of ankle joint moment-angle curve during late stance. showed that NAS was not significantly influenced by age (r = -0.11, p = 0.12), and that the confounding factor of walking speed had a significant, positive relationship with NAS (r = 0.59, p < 0.001). By determining that gait speed, not age, is related to NAS in older adults, this study represents the initial step towards objectively prescribing PD-AFO bending stiffness to achieve a targeted gait speed for older adults with plantar flexor weakness. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. The Effects of Stroke Type, Locus, and Extent on Long-Term Outcome of Gait Rehabilitation: The LEAPS Experience.

    PubMed

    Nadeau, Stephen E; Dobkin, Bruce; Wu, Samuel S; Pei, Qinglin; Duncan, Pamela W

    2016-08-01

    Background Paresis in stroke is largely a result of damage to descending corticospinal and corticobulbar pathways. Recovery of paresis predominantly reflects the impact on the neural consequences of this white matter lesion by reactive neuroplasticity (mechanisms involved in spontaneous recovery) and experience-dependent neuroplasticity, driven by therapy and daily experience. However, both theoretical considerations and empirical data suggest that type of stroke (large vessel distribution/lacunar infarction, hemorrhage), locus and extent of infarction (basal ganglia, right-hemisphere cerebral cortex), and the presence of leukoaraiosis or prior stroke might influence long-term recovery of walking ability. In this secondary analysis based on the 408 participants in the Locomotor Experience Applied Post-Stroke (LEAPS) study database, we seek to address these possibilities. Methods Lesion type, locus, and extent were characterized by the 2 neurologists in the LEAPS trial on the basis of clinical computed tomography and magnetic resonance imaging scans. A series of regression models was used to test our hypotheses regarding the effects of lesion type, locus, extent, and laterality on 2- to 12-month change in gait speed, controlling for baseline gait speed, age, and Berg Balance Scale score. Results Gait speed change at 1 year was significantly reduced in participants with basal ganglia involvement and prior stroke. There was a trend toward reduction of gait speed change in participants with lacunar infarctions. The presence of right-hemisphere cortical involvement had no significant impact on outcome. Conclusions Type, locus, and extent of lesion, and the loss of substrate for neuroplastic effect as a result of prior stroke may affect long-term outcome of rehabilitation of hemiparetic gait. © The Author(s) 2015.

  8. “Gunslinger’s gait”: a new cause of unilaterally reduced arm swing

    PubMed Central

    Araújo, Rui; Ferreira, Joaquim J; Antonini, Angelo

    2015-01-01

    Objective To postulate a new possible cause of a unilaterally reduced arm swing in addition to the known medical conditions such as shoulder pathology, Erb’s palsy, stroke, and Parkinson’s disease. Methods Analysis of YouTube videos depicting the gait of highly ranked Russian officials. Results We found a similar walking pattern in President Vladimir Putin, Prime Minister Dmitry Medvedev and three other highly ranked Russian officials, all presenting with a consistently reduced right arm swing in the absence of other overt neurological abnormalities. Conclusions We propose that this new gait pattern, which we term “gunslinger’s gait,” may result from a behavioural adaptation, possibly triggered by KGB or other forms of weapons training where trainees are taught to keep their right hand close to the chest while walking, allowing them to quickly draw a gun when faced with a foe. This should be included in the differential diagnosis of a unilaterally reduced arm swing. PMID:26666758

  9. Horse-like walking, trotting, and galloping derived from kinematic Motion Primitives (kMPs) and their application to walk/trot transitions in a compliant quadruped robot.

    PubMed

    Moro, Federico L; Spröwitz, Alexander; Tuleu, Alexandre; Vespignani, Massimo; Tsagarakis, Nikos G; Ijspeert, Auke J; Caldwell, Darwin G

    2013-06-01

    This manuscript proposes a method to directly transfer the features of horse walking, trotting, and galloping to a quadruped robot, with the aim of creating a much more natural (horse-like) locomotion profile. A principal component analysis on horse joint trajectories shows that walk, trot, and gallop can be described by a set of four kinematic Motion Primitives (kMPs). These kMPs are used to generate valid, stable gaits that are tested on a compliant quadruped robot. Tests on the effects of gait frequency scaling as follows: results indicate a speed optimal walking frequency around 3.4 Hz, and an optimal trotting frequency around 4 Hz. Following, a criterion to synthesize gait transitions is proposed, and the walk/trot transitions are successfully tested on the robot. The performance of the robot when the transitions are scaled in frequency is evaluated by means of roll and pitch angle phase plots.

  10. Insights into gait disorders: walking variability using phase plot analysis, Huntington's disease.

    PubMed

    Collett, Johnny; Esser, Patrick; Khalil, Hanan; Busse, Monica; Quinn, Lori; DeBono, Katy; Rosser, Anne; Nemeth, Andrea H; Dawes, Helen

    2014-09-01

    Huntington's disease (HD) is a progressive inherited neurodegenerative disorder. Identifying sensitive methodologies to quantitatively measure early motor changes have been difficult to develop. This exploratory observational study investigated gait variability and symmetry in HD using phase plot analysis. We measured the walking of 22 controls and 35 HD gene carriers (7 premanifest (PreHD)), 16 early/mid (HD1) and 12 late stage (HD2) in Oxford and Cardiff, UK. The unified Huntington's disease rating scale-total motor scores (UHDRS-TMS) and disease burden scores (DBS) were used to quantify disease severity. Data was collected during a clinical walk test (8.8 or 10 m) using an inertial measurement unit attached to the trunk. The 6 middle strides were used to calculate gait variability determined by spatiotemporal parameters (co-efficient of variation (CoV)) and phase plot analysis. Phase plots considered the variability in consecutive wave forms from vertical movement and were quantified by SDA (spatiotemporal variability), SDB (temporal variability), ratio ∀ (ratio SDA:SDB) and Δangleβ (symmetry). Step time CoV was greater in manifest HD (p<0.01, both manifest groups) than controls, as was stride length CoV for HD2 (p<0.01). No differences were found in spatiotemporal variability between PreHD and controls (p>0.05). Phase plot analysis identified differences between manifest HD and controls for SDB, Ratio ∀ and Δangle (all p<0.01, both manifest groups). Furthermore Ratio ∀ was smaller in PreHD compared with controls (p<0.01). Ratio ∀ also produced the strongest correlation with UHDRS-TMS (r=-0.61, p<0.01) and was correlated with DBS (r=-0.42, p=0.02). Phase plot analysis may be a sensitive method of detecting gait changes in HD and can be performed quickly during clinical walking tests. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Wavelet-based multiscale analysis of minimum toe clearance variability in the young and elderly during walking.

    PubMed

    Khandoker, Ahsan H; Karmakar, Chandan K; Begg, Rezaul K; Palaniswami, Marimuthu

    2007-01-01

    As humans age or are influenced by pathology of the neuromuscular system, gait patterns are known to adjust, accommodating for reduced function in the balance control system. The aim of this study was to investigate the effectiveness of a wavelet based multiscale analysis of a gait variable [minimum toe clearance (MTC)] in deriving indexes for understanding age-related declines in gait performance and screening of balance impairments in the elderly. MTC during walking on a treadmill for 30 healthy young, 27 healthy elderly and 10 falls risk elderly subjects with a history of tripping falls were analyzed. The MTC signal from each subject was decomposed to eight detailed signals at different wavelet scales by using the discrete wavelet transform. The variances of detailed signals at scales 8 to 1 were calculated. The multiscale exponent (beta) was then estimated from the slope of the variance progression at successive scales. The variance at scale 5 was significantly (p<0.01) different between young and healthy elderly group. Results also suggest that the Beta between scales 1 to 2 are effective for recognizing falls risk gait patterns. Results have implication for quantifying gait dynamics in normal, ageing and pathological conditions. Early detection of gait pattern changes due to ageing and balance impairments using wavelet-based multiscale analysis might provide the opportunity to initiate preemptive measures to be undertaken to avoid injurious falls.

  12. Asymmetry in gait pattern following bicondylar tibial plateau fractures-A prospective one-year cohort study.

    PubMed

    Elsoe, Rasmus; Larsen, Peter

    2017-07-01

    Despite the high number of studies evaluating outcomes following tibial plateau fractures, the literature lacks studies including the objective assessment of gait pattern. The purpose of the present study was to evaluate asymmetry in gait patterns at 12 months after frame removal following ring fixation of a tibial plateau fracture. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns 12 months after frame removal measured with a pressure-sensitive mat. The mat registers footprints and present gait speed, cadence, as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. Twenty-three patients were included with a mean age of 54.4 years (32-78 years). Patients presented with a shorter step-length of the injured leg compared to the non-injured leg (asymmetry of 11.3%). Analysis of single-support showed shorter support time of the injured leg compared to the non-injured leg (asymmetry of 8.7%). Moreover, analysis of swing-time showed increased swing-time of the injured leg (asymmetry of 8.9%). Compared to a healthy reference population, increased asymmetry in all gait patterns was observed. The association between asymmetry and health-related quality of life (HRQOL) showed moderate associations (single-support: R=0.50, P=0.03; step-length: R=0.43, P=0.07; swing-time: R=0.46, P=0.05). Compared to a healthy reference population, gait asymmetry is common 12 months after frame removal in patients treated with external ring fixation following a tibial plateau fracture of the tibia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Symmetry in locomotor central pattern generators and animal gaits

    NASA Astrophysics Data System (ADS)

    Golubitsky, Martin; Stewart, Ian; Buono, Pietro-Luciano; Collins, J. J.

    1999-10-01

    Animal locomotion is controlled, in part, by a central pattern generator (CPG), which is an intraspinal network of neurons capable of generating a rhythmic output. The spatio-temporal symmetries of the quadrupedal gaits walk, trot and pace lead to plausible assumptions about the symmetries of locomotor CPGs. These assumptions imply that the CPG of a quadruped should consist of eight nominally identical subcircuits, arranged in an essentially unique matter. Here we apply analogous arguments to myriapod CPGs. Analyses based on symmetry applied to these networks lead to testable predictions, including a distinction between primary and secondary gaits, the existence of a new primary gait called `jump', and the occurrence of half-integer wave numbers in myriapod gaits. For bipeds, our analysis also predicts two gaits with the out-of-phase symmetry of the walk and two gaits with the in-phase symmetry of the hop. We present data that support each of these predictions. This work suggests that symmetry can be used to infer a plausible class of CPG network architectures from observed patterns of animal gaits.

  14. Effects of robot assisted gait training in progressive supranuclear palsy (PSP): a preliminary report

    PubMed Central

    Sale, Patrizio; Stocchi, Fabrizio; Galafate, Daniele; De Pandis, Maria Francesca; Le Pera, Domenica; Sova, Ivan; Galli, Manuela; Foti, Calogero; Franceschini, Marco

    2014-01-01

    Background and Purpose: Progressive supranuclear palsy (PSP) is a rare neurodegenerative disease clinically characterized by prominent axial extrapyramidal motor symptoms with frequent falls. Over the last years the introduction of robotic technologies to recover lower limb function has been greatly employed in the rehabilitative practice. This observational trial is aimed at investigating the changes in the main spatiotemporal following end-effector robot training in people with PSP. Method: Pilot observational trial. Participants: Five cognitively intact participants with PSP and gait disorders. Interventions: Patients were submitted to a rehabilitative program of robot-assisted walking sessions for 45 min, 5 times a week for 4 weeks. Main outcome measures: The spatiotemporal parameters at the beginning (T0) and at the end of treatment (T1) were recorded by a gait analysis laboratory. Results: Robot training was feasible, acceptable and safe and all participants completed the prescribed training sessions. All patients showed an improvement in the gait spatiotemporal index (Mean velocity, Cadence, Step length, and Step width) (T0 vs. T1). Conclusions: Robot training is a feasible and safe form of rehabilitation for cognitively intact people with PSP. The lack of side effects and the positive results in the gait parameter index in all patients support the recommendation to extend the trials of this treatment. Further investigation regarding the effectiveness of robot training in time is necessary. Trial registration: ClinicalTrials.gov NCT01668407. PMID:24860459

  15. The Ergogenic Effect of Elastic Therapeutic Tape on Stride and Step Length in Fatigued Runners

    PubMed Central

    Ward, John; Sorrels, Kenneth; Coats, Jesse; Pourmoghaddam, Amir; Moskop, JoAnn; Ueckert, Kate; Glass, Amanda

    2014-01-01

    Objective The purpose of this study was to determine if elastic therapeutic tape placed on anterior lower limbs would affect stride and step length in fatigued runners’ gait. Methods Forty-two healthy participants were equally divided into a kinesiology tape group (Rocktape) and a no-tape control group. Participants in both groups underwent a baseline running gait test at 6 mph without tape. After this, participants engaged in an exhaustive lower body fatigue protocol until they reached maximal volitional exhaustion. Participants were then randomized to 1 of 2 interventions: (1) Experimental group, which had kinesiology tape placed under tension on the anterior aspect of their lower limbs bilaterally from the upper thigh to just below the patella, or (2) Control group, which did not receive taping. All participants then engaged in a similar 6-mph running gait postanalysis. Participant’s gait was analyzed for 90 seconds during each test iteration. Researchers used a 2-way repeated-measures analysis of variance considering fatigue (prefatigue, postfatigue) and group (tape, no-tape) as subject factors. Results After the fatigue protocol, the no-tape group demonstrated a significant decrease in step length of 14.2 mm (P = .041) and stride length of 29.4 mm (P = .043). The kinesiology tape group did not demonstrate a significant decline in these gait parameters. Conclusions In this preliminary study, placing elastic therapeutic tape over the anterior lower limbs demonstrated short-term preservation of runner step length and stride length in a fatigued state. PMID:25435835

  16. Nonlinear analysis of gait kinematics to track changes in oxygen consumption in prolonged load carriage walking: a pilot study.

    PubMed

    Schiffman, Jeffrey M; Chelidze, David; Adams, Albert; Segala, David B; Hasselquist, Leif

    2009-09-18

    Linking human mechanical work to physiological work for the purpose of developing a model of physical fatigue is a complex problem that cannot be solved easily by conventional biomechanical analysis. The purpose of the study was to determine if two nonlinear analysis methods can address the fundamental issue of utilizing kinematic data to track oxygen consumption from a prolonged walking trial: we evaluated the effectiveness of dynamical systems and fractal analysis in this study. Further, we selected, oxygen consumption as a measure to represent the underlying physiological measure of fatigue. Three male US Army Soldier volunteers (means: 23.3 yr; 1.80 m; 77.3 kg) walked for 120 min at 1.34 m/s with a 40-kg load on a level treadmill. Gait kinematic data and oxygen consumption (VO(2)) data were collected over the 120-min period. For the fractal analysis, utilizing stride interval data, we calculated fractal dimension. For the dynamical systems analysis, kinematic angle time series were used to estimate phase space warping based features at uniform time intervals: smooth orthogonal decomposition (SOD) was used to extract slowly time-varying trends from these features. Estimated fractal dimensions showed no apparent trend or correlation with independently measured VO(2). While inter-individual difference did exist in the VO(2) data, dominant SOD time trends tracked and correlated with the VO(2) for all volunteers. Thus, dynamical systems analysis using gait kinematics may be suitable to develop a model to predict physiologic fatigue based on biomechanical work.

  17. Effect of aquatic dual-task training on balance and gait in stroke patients

    PubMed Central

    Kim, Kyoung; Lee, Dong-Kyu; Kim, Eun-Kyung

    2016-01-01

    [Purpose] The purpose of this study was to determine the effect of aquatic dual-task training on balance and gait in stroke patients. [Subjects and Methods] Twenty stroke patients were divided into the experimental (n=10) and control (n=10) groups. Both groups underwent neurodevelopmental treatment. The experimental group additionally underwent aquatic dual-task training for 30 minutes a day, 5 days a week, for 6 weeks. Balance was measured using the Berg balance scale, Five Times Sit-to Stand Test, and Functional Reach Test. Gait was measured using the 10-Meter Walk Test, Timed Up and Go Test, and Functional Gait Assessment. [Results] For intragroup comparison, the experimental group showed a significant change after the experiment in all balance and gait assessment tests. For intergroup comparison, the experimental group showed relatively more significant change after the experiment in all balance and gait assessment tests. [Conclusion] Our results showed that aquatic dual-task training has a positive effect on balance and gait in stroke patients. PMID:27512261

  18. Effect of aquatic dual-task training on balance and gait in stroke patients.

    PubMed

    Kim, Kyoung; Lee, Dong-Kyu; Kim, Eun-Kyung

    2016-07-01

    [Purpose] The purpose of this study was to determine the effect of aquatic dual-task training on balance and gait in stroke patients. [Subjects and Methods] Twenty stroke patients were divided into the experimental (n=10) and control (n=10) groups. Both groups underwent neurodevelopmental treatment. The experimental group additionally underwent aquatic dual-task training for 30 minutes a day, 5 days a week, for 6 weeks. Balance was measured using the Berg balance scale, Five Times Sit-to Stand Test, and Functional Reach Test. Gait was measured using the 10-Meter Walk Test, Timed Up and Go Test, and Functional Gait Assessment. [Results] For intragroup comparison, the experimental group showed a significant change after the experiment in all balance and gait assessment tests. For intergroup comparison, the experimental group showed relatively more significant change after the experiment in all balance and gait assessment tests. [Conclusion] Our results showed that aquatic dual-task training has a positive effect on balance and gait in stroke patients.

  19. An Ambulatory System for Gait Monitoring Based on Wireless Sensorized Insoles.

    PubMed

    González, Iván; Fontecha, Jesús; Hervás, Ramón; Bravo, José

    2015-07-09

    A new gait phase detection system for continuous monitoring based on wireless sensorized insoles is presented. The system can be used in gait analysis mobile applications, and it is designed for real-time demarcation of gait phases. The system employs pressure sensors to assess the force exerted by each foot during walking. A fuzzy rule-based inference algorithm is implemented on a smartphone and used to detect each of the gait phases based on the sensor signals. Additionally, to provide a solution that is insensitive to perturbations caused by non-walking activities, a probabilistic classifier is employed to discriminate walking forward from other low-level activities, such as turning, walking backwards, lateral walking, etc. The combination of these two algorithms constitutes the first approach towards a continuous gait assessment system, by means of the avoidance of non-walking influences.

  20. Clinical Measures Are Feasible and Sensitive to Assess Balance and Gait Capacities in Older Persons with Mild to Moderate Intellectual Disabilities

    ERIC Educational Resources Information Center

    Enkelaar, Lotte; Smulders, Ellen; Lantman-de Valk, Henny van Schrojenstein; Weerdesteyn, Vivian; Geurts, Alexander C. H.

    2013-01-01

    Mobility limitations are common in persons with Intellectual Disabilities (ID). Differences in balance and gait capacities between persons with ID and controls have mainly been demonstrated by instrumented assessments (e.g. posturography and gait analysis), which require sophisticated and expensive equipment such as force plates or a 3D motion…

  1. Is Interlimb Coordination during Walking Preserved in Children with Cerebral Palsy?

    ERIC Educational Resources Information Center

    Meyns, Pieter; Van Gestel, Leen; Bruijn, Sjoerd M.; Desloovere, Kaat; Swinnen, Stephan P.; Duysens, Jacques

    2012-01-01

    Arm movements during gait in children with cerebral palsy (CP) are altered compared to typically developing children (TD). We investigated whether these changes in arm movements alter interlimb coordination in CP gait. 3D gait analysis was performed in CP (diplegia [DI]: N = 15 and hemiplegia [HE]: N = 11) and TD (N = 24) children at preferred and…

  2. Multicomponent physical exercise with simultaneous cognitive training to enhance dual-task walking of older adults: a secondary analysis of a 6-month randomized controlled trial with 1-year follow-up

    PubMed Central

    Eggenberger, Patrick; Theill, Nathan; Holenstein, Stefan; Schumacher, Vera; de Bruin, Eling D

    2015-01-01

    Background About one-third of people older than 65 years fall at least once a year. Physical exercise has been previously demonstrated to improve gait, enhance physical fitness, and prevent falls. Nonetheless, the addition of cognitive training components may potentially increase these effects, since cognitive impairment is related to gait irregularities and fall risk. We hypothesized that simultaneous cognitive–physical training would lead to greater improvements in dual-task (DT) gait compared to exclusive physical training. Methods Elderly persons older than 70 years and without cognitive impairment were randomly assigned to the following groups: 1) virtual reality video game dancing (DANCE), 2) treadmill walking with simultaneous verbal memory training (MEMORY), or 3) treadmill walking (PHYS). Each program was complemented with strength and balance exercises. Two 1-hour training sessions per week over 6 months were applied. Gait variables, functional fitness (Short Physical Performance Battery, 6-minute walk), and fall frequencies were assessed at baseline, after 3 months and 6 months, and at 1-year follow-up. Multiple regression analyses with planned comparisons were carried out. Results Eighty-nine participants were randomized to three groups initially; 71 completed the training and 47 were available at 1-year follow-up. DANCE/MEMORY showed a significant advantage compared to PHYS in DT costs of step time variability at fast walking (P=0.044). Training-specific gait adaptations were found on comparing DANCE and MEMORY: DANCE reduced step time at fast walking (P=0.007) and MEMORY reduced gait variability in DT and DT costs at preferred walking speed (both trend P=0.062). Global linear time effects showed improved gait (P<0.05), functional fitness (P<0.05), and reduced fall frequency (−77%, P<0.001). Only single-task fast walking, gait variability at preferred walking speed, and Short Physical Performance Battery were reduced at follow-up (all P<0.05 or trend). Conclusion Long-term multicomponent cognitive–physical and exclusive physical training programs demonstrated similar potential to counteract age-related decline in physical functioning. PMID:26604719

  3. Somatosensory inputs by application of KinesioTaping: effects on spasticity, balance, and gait in chronic spinal cord injury

    PubMed Central

    Tamburella, Federica; Scivoletto, Giorgio; Molinari, Marco

    2014-01-01

    Introduction: Leg paralysis, spasticity, reduced interlimb coordination, and impaired balance are the chief limitations to overground ambulation in subjects with incomplete spinal cord injury (SCI). In recent years, the application of KinesioTaping (KT) has been proposed to enhance sensory inputs, decreasing spasticity by proprioception feedback and relieving abnormal muscle tension. Because no studies have examined KT-based techniques in SCI subjects, our goal was to analyze the effects of ankle joint KT on spasticity, balance, and gait. Materials and Methods: A randomized crossover case control design was used to compare the effects of KT and conventional nonelastic silk tape (ST) in 11 chronic SCI subjects, AIS level D, with soleus/gastrocnemius (S/G) muscle spasticity and balance and gait impairments. Treatment: 48 h of treatment with KT or ST was followed by 48 h with the other technique after 1 week. A single Y-strip of Cure© tape (KT) and ST was to the S and G muscles with 0% stretch. Before and 48 h after of application of KT and ST, clinical data on the range of motion (ROM), spasticity, clonus, pain, balance, and gait were collected. Stabilometric platform assessment of center of pressure (COP) movements; bidimensional gait analysis; and recording of electromyographic (EMG) activity of the S, G, and tibialis anterior and extensor hallucis lungus muscles were also performed. Results: Only KT had significant effects on spasticity (p < 0.05), clonus (p < 0.001) and COP movements (p < 0.05), kinematic gait parameters (p < 0.001), and EMG activity (p < 0.001). Comparison between ST and KT improvements pointed out significant differences as concerns ROM (p < 0.001), spasticity (p < 0.001), clonus (p < 0.001), pain (p < 0.001), COP parameters (p < 0.05), and most kinematic gait data (p < 0.05). Discussion: Short-term application of KT reduces spasticity and pain and improves balance and gait in chronic SCI subjects. Although these data are promising, they require confirmation in a larger cohort of patients. PMID:24910607

  4. Effects of Design Variants in Lower-Limb Prostheses on Gait Synergy

    PubMed Central

    Pitkin, Mark R.

    2016-01-01

    A lower-limb prosthesis is the mechanical device with which an amputee’s residual limb interacts with the walking surface. The pressure and shear forces that affect the residuum due to prosthesis use are the sources of pain, residual-limb skin problems and gait deviations. Direct approaches to reducing these problems include improving fit, alignment technique and socket design as well as increasing cushioning with socket liners. A summary of typical malalignments and their consequences is presented. The malalignments are considered sources of excessive moments applied to the residuum, which simplifies the analysis of a patient’s gait. A better design of prosthetic joints could improve prosthetic gait. This article addresses the key mechanical parameter of prosthetic joints, namely the dependence “moment of resistance/angle of deflection.” A mathematical model has been developed that links stresses on the residuum in transtibial amputees with the moment of resistance in the prosthetic ankle at the critical gait phases. Analysis of the model yields a substantial decrease in stresses on the residuum during the most demanding, load-bearing phase of stance if the moment of resistance in the ankle is similar to that seen in the biological ankle joint. Gait study shows use of the experimental rolling-joint prosthetic foot more closely simulates normal gait synergy than the SACH foot. PMID:27087763

  5. A Pilot Study of Gait Function in Farmworkers in Eastern North Carolina.

    PubMed

    Nguyen, Ha T; Kritchevsky, Stephen B; Foxworth, Judy L; Quandt, Sara A; Summers, Phillip; Walker, Francis O; Arcury, Thomas A

    2015-01-01

    Farmworkers endure many job-related hazards, including fall-related work injuries. Gait analysis may be useful in identifying potential fallers. The goal of this pilot study was to explore differences in gait between farmworkers and non-farmworkers. The sample included 16 farmworkers and 24 non-farmworkers. Gait variables were collected using the portable GAITRite system, a 16-foot computerized walkway. Generalized linear regression models were used to examine group differences. All models were adjusted for two established confounders, age and body mass index. There were no significant differences in stride length, step length, double support time, and base of support; but farmworkers had greater irregularity of stride length (P = .01) and step length (P = .08). Farmworkers performed significantly worse on gait velocity (P = .003) and cadence (P < .001) relative to non-farmworkers. We found differences in gait function between farmworkers and non-farmworkers. These findings suggest that measuring gait with a portable walkway system is feasible and informative in farmworkers and may possibly be of use in assessing fall risk.

  6. Efficacy and Safety of Pedunculopontine Nuclei (PPN) Deep Brain Stimulation in the Treatment of Gait Disorders: A Meta-Analysis of Clinical Studies.

    PubMed

    Golestanirad, Laleh; Elahi, Behzad; Graham, Simon J; Das, Sunit; Wald, Lawrence L

    2016-01-01

    Pedunculopontine nucleus (PPN) has complex reciprocal connections with basal ganglia, especially with internal globus pallidus and substantia nigra, and it has been postulated that PPN stimulation may improve gait instability and freezing of gait. In this meta-analysis, we will assess the evidence for PPN deep brain stimulation in treatment of gait and motor abnormalities especially focusing on Parkinson disease patients. PubMed and Scopus electronic databases were searched for related studies published before February 2014. Medline (1966-2014), Embase (1974-2010), CINAHL, Web of Science, Scopus bibliographic, and Google Scholar databases (1960-2014) were also searched for studies investigating effect of PPN deep brain stimulation in treatment of postural and postural instability and total of ten studies met the inclusion criteria for this analysis. Our findings showed a significant improvement in postural instability (p<0.001) and motor symptoms of Parkinson disease on and off medications (p<0.05), but failed to show improvement in freezing of gait. Despite significant improvement in postural instability observed in included studies, evidence from current literature is not sufficient to generalize these findings to the majority of patients.

  7. Subliminal gait initiation deficits in REM sleep behavior disorder: a harbinger of freezing of gait?

    PubMed Central

    Alibiglou, L.; Videnovic, A.; Planetta, P.J.; Vaillancourt, D.E.; MacKinnon, C.D.

    2016-01-01

    Background Muscle activity during REM sleep is markedly increased in people with REM sleep behavior disorder (RBD) and people with Parkinson’s disease (PD) who have freezing of gait. This study examined if individuals with RBD, who do not have a diagnosis of PD, show abnormalities in gait initiation that resemble the impairments observed in PD and whether there is a relationship between these deficits and the level of REM sleep without atonia. Methods Gait initiation and polysomnography studies were conducted in four groups of 10 subjects each: RBD, PD with and without freezing of gait and control subjects. Results Significant reductions were seen in the posterior shift of the center of pressure during the propulsive phase of gait initiation in the RBD and PD with freezing of gait groups compared with controls and PD non-freezers. These reductions negatively correlated with the amount of REM sleep without atonia. The duration of the initial dorsiflexor muscle burst during gait initiation was significantly reduced in both PD groups and the RBD cohort. Conclusions These results provide evidence that people with RBD, prior to a diagnosis of a degenerative neurologic disorder, show alterations in the coupling of posture and gait similar to those seen in PD. The correlation between increased REM sleep without atonia and deficits in forward propulsion during the push-off phase of gait initiation suggests that abnormities in the regulation of muscle tone during REM sleep may be related to the pathogenesis of freezing of gait. PMID:27250871

  8. Accelerometric gait analysis for use in hospital outpatients.

    PubMed

    Auvinet, B; Chaleil, D; Barrey, E

    1999-01-01

    To provide clinicians with a quantitative human gait analysis tool suitable for routine use. We evaluated the reproducibility, sensitivity, and specificity of gait analysis based on measurements of acceleration at a point near the center of gravity of the body. Two accelerometers held over the middle of the low back by a semi-elastic belt were used to record craniocaudal and side-to-side accelerations at a frequency of 50 Hz. Subjects were asked to walk at their normal speed to the end of a straight 40 meter-long hospital corridor and back. A 20-second period of stabilized walking was used to calculate cycle frequency, stride symmetry, and stride regularity. Symmetry and regularity were each derived from an auto-correlation coefficient; to convert their distribution from nonnormal to normal, Fisher's Z transformation was applied to the auto-coefficients for these two variables. Intraobserver reproducibility was evaluated by asking the same observer to test 16 controls on three separate occasions at two-day intervals and interobserver reproducibility by asking four different observers to each test four controls (Latin square). Specificity and sensitivity were determined by testing 139 controls and 63 patients. The 139 controls (70 women and 69 men) were divided into five age groups (third through seventh decades of life). The 63 patients had a noninflammatory musculoskeletal condition predominating on one side. ROC curves were used to determine the best cutoffs for separating normal from abnormal values. Neither intra- nor interobserver variability was significant (P > 0.05). Cycle frequency was significantly higher in female than in male controls (1.05 +/- 0.06 versus 0.98 +/- 0.05 cycles/s; P < 0.001). Neither symmetry nor regularity were influenced by gender in the controls; both variables were also unaffected by age, although nonsignificant decreases were found in the 61 to 70-year age group, which included only nine subjects. In the ROC curve analysis, the area under the curve was high for all three variables (frequency, 0.81 +/- 0.04; symmetry, 0.85 +/- 0.03; and regularity, 0.88 +/- 0.03), establishing that there was a good compromise between sensitivity and specificity. Our gait analysis method offers satisfactory reproducibility and is sufficiently sensitive and specific to be used by clinicians in the quantitative evaluation of gait abnormalities.

  9. Neurological Gait Abnormalities And Risk Of Falls In Older Adults

    PubMed Central

    Verghese, Joe; Ambrose, Anne F; Lipton, Richard B; Wang, Cuiling

    2009-01-01

    Objective To estimate the validity of neurological gait evaluations in predicting falls in older adults. Methods We studied 632 adults age 70 and over (mean age 80.6 years, 62% women) enrolled in the Einstein Aging Study whose walking patterns were evaluated by study clinicians using a clinical gait rating scale. Association of neurological gaits and six subtypes (hemiparetic, frontal, Parkinsonian, unsteady, neuropathic, and spastic) with incident falls was studied using generalized estimation equation procedures adjusted for potential confounders, and reported as risk ratio with 95% confidence intervals (CI). Results Over a mean follow-up of 21 months, 244 (39%) subjects fell. Mean fall rate was 0.47 falls per person year. At baseline, 120 subjects were diagnosed with neurological gaits. Subjects with neurological gaits were at increased risk of falls (risk ratio 1.49, 95% CI 1.11 – 2.00). Unsteady (risk ratio 1.52, 95% CI 1.04 – 2.22), and neuropathic gait (risk ratio 1.94, 95% CI 1.07 – 3.11) were the two gait subtypes that predicted risk of falls. The results remained significant after accounting for disability and cognitive status, and also with injurious falls as the outcome. Conclusions Neurological gaits and subtypes are independent predictors of falls in older adults. Neurological gait assessments will help clinicians identify and institute preventive measures in older adults at high risk for falls. PMID:19784714

  10. Morphofunctional changes in distribution of pressure center in multiple sclerosis.

    PubMed

    Neamţu, Marius Cristian; Neamţu, Oana Maria; Enescu Bieru, Denisa; Marin, Mihnea Ion; Rusu, Mihai Robert; Tudorache, Ştefania; Brăila, Anca Daniela; Poiană, Cătălina; Rusu, Ligia

    2018-01-01

    Gait evaluation and assessment of motor performance are of utmost importance in the clinical management of multiple sclerosis (MS). A new approach to the analysis of static and dynamic balance of MS patients is the use of complex biomechanical analysis that includes an analysis of the distribution of the center of pressure (DCP) and loading, measured by using the pressure and force platforms. The study was conducted on a total of 18 patients with MS, with the mean age of 41.2 years old, divided into two groups, according to the presence of clinically detectable gait disturbances. The biomechanical analysis that included the assessment of the loading and DPC was performed using the platform of force distribution. DPC represented the center of all the forces applied and its value could appreciate the mediolateral stability, hence the pronation or, respectively, the supination. Group 1, consisting of 12 patients with MS with clinically detectable gait disorders, including six men and six women, and group 2, of six MS patients without clinically detectable gait disorders, including two men and four women. For group 1, the center of pressure had a left-right asymmetric distribution, and also an anterior-posterior one. There was a predominant distribution at the medial heel, at metatarsals 1-3 and at the hallux. For group 2, the analysis of the plantograms recorded in our study indicated a tendency of the distribution of the pressure center in the metatarsals 2, 3 and less in the heel. The analysis of the loading and distribution of the pressure center was important not only to appreciate the static equilibrium disorders but also to appreciate how these disorders affected the gait initiation, since the patients suffered from anterior-posterior and mediolateral disorders, which produced spatial and temporal distortion preventing gait initiation. In the study of pressure and force, we noticed a predominant distribution on the lateral region of the heel, explained by an attempt of the body to compensate the disorders of balance and orientation of the reaction force of the ground to normalize the gait.

  11. Bifurcation and chaos in the simple passive dynamic walking model with upper body.

    PubMed

    Li, Qingdu; Guo, Jianli; Yang, Xiao-Song

    2014-09-01

    We present some rich new complex gaits in the simple walking model with upper body by Wisse et al. in [Robotica 22, 681 (2004)]. We first show that the stable gait found by Wisse et al. may become chaotic via period-doubling bifurcations. Such period-doubling routes to chaos exist for all parameters, such as foot mass, upper body mass, body length, hip spring stiffness, and slope angle. Then, we report three new gaits with period 3, 4, and 6; for each gait, there is also a period-doubling route to chaos. Finally, we show a practical method for finding a topological horseshoe in 3D Poincaré map, and present a rigorous verification of chaos from these gaits.

  12. Bifurcation and chaos in the simple passive dynamic walking model with upper body

    NASA Astrophysics Data System (ADS)

    Li, Qingdu; Guo, Jianli; Yang, Xiao-Song

    2014-09-01

    We present some rich new complex gaits in the simple walking model with upper body by Wisse et al. in [Robotica 22, 681 (2004)]. We first show that the stable gait found by Wisse et al. may become chaotic via period-doubling bifurcations. Such period-doubling routes to chaos exist for all parameters, such as foot mass, upper body mass, body length, hip spring stiffness, and slope angle. Then, we report three new gaits with period 3, 4, and 6; for each gait, there is also a period-doubling route to chaos. Finally, we show a practical method for finding a topological horseshoe in 3D Poincaré map, and present a rigorous verification of chaos from these gaits.

  13. Combining gait optimization with passive system to increase the energy efficiency of a humanoid robot walking movement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira, Ana I.; ALGORITMI,University of Minho; Lima, José

    There are several approaches to create the Humanoid robot gait planning. This problem presents a large number of unknown parameters that should be found to make the humanoid robot to walk. Optimization in simulation models can be used to find the gait based on several criteria such as energy minimization, acceleration, step length among the others. The energy consumption can also be reduced with elastic elements coupled to each joint. The presented paper addresses an optimization method, the Stretched Simulated Annealing, that runs in an accurate and stable simulation model to find the optimal gait combined with elastic elements. Finalmore » results demonstrate that optimization is a valid gait planning technique.« less

  14. Flexible Piezoelectric Sensor-Based Gait Recognition.

    PubMed

    Cha, Youngsu; Kim, Hojoon; Kim, Doik

    2018-02-05

    Most motion recognition research has required tight-fitting suits for precise sensing. However, tight-suit systems have difficulty adapting to real applications, because people normally wear loose clothes. In this paper, we propose a gait recognition system with flexible piezoelectric sensors in loose clothing. The gait recognition system does not directly sense lower-body angles. It does, however, detect the transition between standing and walking. Specifically, we use the signals from the flexible sensors attached to the knee and hip parts on loose pants. We detect the periodic motion component using the discrete time Fourier series from the signal during walking. We adapt the gait detection method to a real-time patient motion and posture monitoring system. In the monitoring system, the gait recognition operates well. Finally, we test the gait recognition system with 10 subjects, for which the proposed system successfully detects walking with a success rate over 93 %.

  15. Optimality Principles for Model-Based Prediction of Human Gait

    PubMed Central

    Ackermann, Marko; van den Bogert, Antonie J.

    2010-01-01

    Although humans have a large repertoire of potential movements, gait patterns tend to be stereotypical and appear to be selected according to optimality principles such as minimal energy. When applied to dynamic musculoskeletal models such optimality principles might be used to predict how a patient’s gait adapts to mechanical interventions such as prosthetic devices or surgery. In this paper we study the effects of different performance criteria on predicted gait patterns using a 2D musculoskeletal model. The associated optimal control problem for a family of different cost functions was solved utilizing the direct collocation method. It was found that fatigue-like cost functions produced realistic gait, with stance phase knee flexion, as opposed to energy-related cost functions which avoided knee flexion during the stance phase. We conclude that fatigue minimization may be one of the primary optimality principles governing human gait. PMID:20074736

  16. To pace or not to pace: a pilot study of four- and five-gaited Icelandic horses homozygous for the DMRT3 'Gait Keeper' mutation.

    PubMed

    Jäderkvist Fegraeus, K; Hirschberg, I; Árnason, T; Andersson, L; Velie, B D; Andersson, L S; Lindgren, G

    2017-12-01

    The Icelandic horse is a breed known mainly for its ability to perform the ambling four-beat gait 'tölt' and the lateral two-beat gait pace. The natural ability of the breed to perform these alternative gaits is highly desired by breeders. Therefore, the discovery that a nonsense mutation (C>A) in the DMRT3 gene was the main genetic factor for horses' ability to perform gaits in addition to walk, trot and canter was of great interest. Although several studies have demonstrated that homozygosity for the DMRT3 mutation is important for the ability to pace, only about 70% of the homozygous mutant (AA) Icelandic horses are reported to pace. The aim of the study was to genetically compare four- and five-gaited (i.e. horses with and without the ability to pace) AA Icelandic horses by performing a genome-wide association (GWA) analysis. All horses (n = 55) were genotyped on the 670K Axiom Equine Genotyping Array, and a GWA analysis was performed using the genabel package in r. No SNP demonstrated genome-wide significance, implying that the ability to pace goes beyond the presence of a single gene variant. Despite its limitations, the current study provides additional information regarding the genetic complexity of pacing ability in horses. However, to fully understand the genetic differences between four- and five-gaited AA horses, additional studies with larger sample materials and consistent phenotyping are needed. © 2017 Stichting International Foundation for Animal Genetics.

  17. Stimulation of the mesencephalic locomotor region for gait recovery after stroke.

    PubMed

    Fluri, Felix; Malzahn, Uwe; Homola, György A; Schuhmann, Michael K; Kleinschnitz, Christoph; Volkmann, Jens

    2017-11-01

    One-third of all stroke survivors are unable to walk, even after intensive physiotherapy. Thus, other concepts to restore walking are needed. Because electrical stimulation of the mesencephalic locomotor region (MLR) is known to elicit gait movements, this area might be a promising target for restorative neurostimulation in stroke patients with gait disability. The present study aims to delineate the effect of high-frequency stimulation of the MLR (MLR-HFS) on gait impairment in a rodent stroke model. Male Wistar rats underwent photothrombotic stroke of the right sensorimotor cortex and chronic implantation of a stimulating electrode into the right MLR. Gait was assessed using clinical scoring of the beam-walking test and video-kinematic analysis (CatWalk) at baseline and on days 3 and 4 after experimental stroke with and without MLR-HFS. Kinematic analysis revealed significant changes in several dynamic and static gait parameters resulting in overall reduced gait velocity. All rats exhibited major coordination deficits during the beam-walking challenge and were unable to cross the beam. Simultaneous to the onset of MLR-HFS, a significantly higher walking speed and improvements in several dynamic gait parameters were detected by the CatWalk system. Rats regained the ability to cross the beam unassisted, showing a reduced number of paw slips and misses. MLR-HFS can improve disordered locomotor function in a rodent stroke model. It may act by shielding brainstem and spinal locomotor centers from abnormal cortical input after stroke, thus allowing for compensatory and independent action of these circuits. Ann Neurol 2017;82:828-840. © 2017 American Neurological Association.

  18. Spatio-temporal gait disorder and gait fatigue index in a six-minute walk test in women with fibromyalgia.

    PubMed

    Heredia-Jimenez, Jose; Latorre-Roman, Pedro; Santos-Campos, Maria; Orantes-Gonzalez, Eva; Soto-Hermoso, Victor M

    2016-03-01

    Gait disorders in fibromyalgia patients affect several gait parameters and different muscle recruitment patterns. The aim of this study was to assess the gait differences observed during a six-minute walk test between fibromyalgia patients and healthy controls. Forty-eight women with fibromyalgia and 15 healthy women were evaluated. Fibromyalgia patients met the American College of Rheumatology criteria for fibromyalgia selected of an ambulatory care. Both patients and controls had a negative history of musculoskeletal disease, neurological disorders, and gait abnormalities. The 15 controls were healthy women matched to the patients in age, height and body weight. Spatio-temporal gait variables and the rate of perceived exertion during the six-minute walk test (all subjects) and Fibromyalgia Impact Questionnaire (fibromyalgia subjects) were evaluated. All walking sets on the GaitRITE were collected and the gait variables were selected at three stages during the six-minute walk test: two sets at the beginning, two sets at 3 min and two sets at the end of the test. In addition, the Fibromyalgia Impact Questionnaire was used for the fibromyalgia patients. Fibromyalgia patients showed a significant decrease in all spatio-temporal gait variables at each of the three stages and had a lower walk distance covered in the six-minute walk test and higher rate of perceived exertion. No correlations were found between the Fibromyalgia Impact Questionnaire and gait variables. The fibromyalgia and control subjects showed lower gait fatigue indices between the middle and last stages. Gait analysis during a six-minute walk test is a good tool to assess the fatigue and physical symptoms of patients with fibromyalgia. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Effects of sex and obesity on gait biomechanics before and six months after total knee arthroplasty: A longitudinal cohort study.

    PubMed

    Paterson, K L; Sosdian, L; Hinman, R S; Wrigley, T V; Kasza, J; Dowsey, M; Choong, P; Bennell, K L

    2018-03-01

    Gait biomechanics, sex, and obesity can contribute to suboptimal outcomes from primary total knee arthroplasty. The aims of this study were to i) determine if sex and/or obesity influence the amount of change in gait biomechanics from pre-surgery to six months post-surgery and; ii) assess if gait returns to normal in men and women. Three-dimensional gait analysis was performed on 43 patients undergoing primary total knee arthroplasty for knee osteoarthritis (pre- and six months post-operative) and 40 asymptomatic controls. Mixed linear regression models were fit to assess which factors influenced change in gait biomechanics within the arthroplasty cohort, and interaction terms were included to assess if biomechanics returned to normal following surgery. Male peak knee adduction moment (p < 0.001) and impulse (p < 0.001) decreased six months following arthroplasty, whilst gait in women remained unchanged after surgery. Obesity did not influence gait changes in men or women. Gait of female arthroplasty participants did not differ from female controls after surgery except for sagittal plane knee range of motion (p = 0.003), whilst men differed from controls for peak knee adduction moment (p = 0.011), knee range of motion (p < 0.001), and peak knee flexion moment (p < 0.001). Sex, but not obesity, influenced changes in gait biomechanics after arthroplasty. Men retained abnormal gait patterns after surgery, whilst women did not. Further research should determine the long-term implications of gait abnormalities seen in men after arthroplasty. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. The gait disorder in downbeat nystagmus syndrome.

    PubMed

    Schniepp, Roman; Wuehr, Max; Huth, Sabrina; Pradhan, Cauchy; Schlick, Cornelia; Brandt, Thomas; Jahn, Klaus

    2014-01-01

    Downbeat nystagmus (DBN) is a common form of acquired fixation nystagmus with key symptoms of oscillopsia and gait disturbance. Gait disturbance could be a result of impaired visual feedback due to the involuntary ocular oscillations. Alternatively, a malfunction of cerebellar locomotor control might be involved, since DBN is considered a vestibulocerebellar disorder. Investigation of walking in 50 DBN patients (age 72 ± 11 years, 23 females) and 50 healthy controls (HS) (age 70 ± 11 years, 23 females) using a pressure sensitive carpet (GAITRite). The patient cohort comprised subjects with only ocular motor signs (DBN) and subjects with an additional limb ataxia (DBNCA). Gait investigation comprised different walking speeds and walking with eyes closed. In DBN, gait velocity was reduced (p<0.001) with a reduced stride length (p<0.001), increased base of support (p<0.050), and increased double support (p<0.001). Walking with eyes closed led to significant gait changes in both HS and DBN. These changes were more pronounced in DBN patients (p<0.001). Speed-dependency of gait variability revealed significant differences between the subgroups of DBN and DBNCA (p<0.050). (I) Impaired visual control caused by involuntary ocular oscillations cannot sufficiently explain the gait disorder. (II) The gait of patients with DBN is impaired in a speed dependent manner. (III) Analysis of gait variability allows distinguishing DBN from DBNCA: Patients with pure DBN show a speed dependency of gait variability similar to that of patients with afferent vestibular deficits. In DBNCA, gait variability resembles the pattern found in cerebellar ataxia.

  1. Foot pressure analysis of gait pattern in older Japanese females requiring different personal care support levels.

    PubMed

    Takayanagi, Naoto; Sudo, Motoki; Fujii, Masahiko; Sakai, Hirokazu; Morimoto, Keiko; Tomisaki, Masumi; Niki, Yoshifumi; Tokimitsu, Ichiro

    2018-03-01

    [Purpose] This study evaluated gait parameters and foot pressure in two regions of the feet among older females with different personal care support needs to analyze factors that contribute to higher support requirements. [Subjects and Methods] Thirty-two older females were divided into support-need and care-need level groups. Gait parameters (speed, cadence, step length, step width, gait angle, toe angle, double support phase, swing phase, and stance phase) and foot pressure during a 5-m walk were measured and analyzed in the two groups. [Results] The percentage of the double support phase on both feet and the right stance phase were significantly higher in the care-need level group, while that of the right swing phase was significantly lower than that of the support-need level group. Additionally, the phase showing peak pressure on the left rear foot was significantly delayed and the left forefoot pressure in the terminal stance was significantly lower in the care-need level group than in the support-need level group. [Conclusion] These findings show that the temporal duration parameters and foot pressure on a particular side were significantly different between the two groups and suggest that these differences were associated with a higher care level.

  2. Real-Time Gait Event Detection Based on Kinematic Data Coupled to a Biomechanical Model.

    PubMed

    Lambrecht, Stefan; Harutyunyan, Anna; Tanghe, Kevin; Afschrift, Maarten; De Schutter, Joris; Jonkers, Ilse

    2017-03-24

    Real-time detection of multiple stance events, more specifically initial contact (IC), foot flat (FF), heel off (HO), and toe off (TO), could greatly benefit neurorobotic (NR) and neuroprosthetic (NP) control. Three real-time threshold-based algorithms have been developed, detecting the aforementioned events based on kinematic data in combination with a biomechanical model. Data from seven subjects walking at three speeds on an instrumented treadmill were used to validate the presented algorithms, accumulating to a total of 558 steps. The reference for the gait events was obtained using marker and force plate data. All algorithms had excellent precision and no false positives were observed. Timing delays of the presented algorithms were similar to current state-of-the-art algorithms for the detection of IC and TO, whereas smaller delays were achieved for the detection of FF. Our results indicate that, based on their high precision and low delays, these algorithms can be used for the control of an NR/NP, with the exception of the HO event. Kinematic data is used in most NR/NP control schemes and is thus available at no additional cost, resulting in a minimal computational burden. The presented methods can also be applied for screening pathological gait or gait analysis in general in/outside of the laboratory.

  3. RISK FACTORS FOR SLOW GAIT SPEED: A NESTED CASE-CONTROL SECONDARY ANALYSIS OF THE MEXICAN HEALTH AND AGING STUDY.

    PubMed

    Pérez-Zepeda, M U; González-Chavero, J G; Salinas-Martinez, R; Gutiérrez-Robledo, L M

    2015-01-01

    Physical performance tests play a major role in the geriatric assessment. In particular, gait speed has shown to be useful for predicting adverse outcomes. However, risk factors for slow gait speed (slowness) are not clearly described. To determine risk factors associated with slowness in Mexican older adults. A two-step process was adopted for exploring the antecedent risk factors of slow gait speed. First, the cut-off values for gait speed were determined in a representative sample of Mexican older adults. Then, antecedent risk factors of slow gait speed (defined using the identified cut-points) were explored in a nested, cohort case-control study. One representative sample of a cross-sectional survey for the first step and the Mexican Health and Aging Study (a cohort characterized by a 10-year follow-up). A 4-meter usual gait speed test was conducted. Lowest gender and height-stratified groups were considered as defining slow gait speed. Sociodemographic characteristics, comorbidities, psychological and health-care related variables were explored to find those associated with the subsequent development of slow gait speed. Unadjusted and adjusted logistic regression models were performed. In the final model, age, diabetes, hypertension, and history of fractures were associated with the development of slow gait speed. Early identification of subjects at risk of developing slow gait speed may halt the path to disability due to the robust association of this physical performance test with functional decline.

  4. Gait performance of children and adolescents with sensorineural hearing loss.

    PubMed

    Melo, Renato de Souza

    2017-09-01

    Several studies have demonstrated that children with sensorineural hearing loss (SNHL) may exhibit balance disorders, which can compromise the gait performance of this population. Compare the gait performance of normal hearing (NH) children and those with SNHL, considering the sex and age range of the sample, and analyze gait performance according to degrees of hearing loss and etiological factors in the latter group. This is a cross-sectional study that assessed 96 students, 48 NH and 48 with SNHL, aged between 7 and 18 years. The Brazilian version of the Dynamic Gait Index (DGI) was used to analyze gait and the Mann-Whitney test for statistical analysis. The group with SNHL obtained lower average gait performance compared to NH subjects (p=0.000). This was also observed when the children were grouped by sex female and male (p=0.000). The same difference occurred when the children were stratified by age group: 7-18 years (p=0.000). The group with severe and profound hearing loss exhibited worse gait performance than those with mild and moderate loss (p=0.048) and children with prematurity as an etiological factor demonstrated the worst gait performance. The children with SNHL showed worse gait performance compared to NH of the same sex and age group. Those with severe and profound hearing loss and prematurity as an etiological factor demonstrated the worst gait performances. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Randomized controlled trial of robot-assisted gait training with dorsiflexion assistance on chronic stroke patients wearing ankle-foot-orthosis.

    PubMed

    Yeung, Ling-Fung; Ockenfeld, Corinna; Pang, Man-Kit; Wai, Hon-Wah; Soo, Oi-Yan; Li, Sheung-Wai; Tong, Kai-Yu

    2018-06-19

    Robot-assisted ankle-foot-orthosis (AFO) can provide immediate powered ankle assistance in post-stroke gait training. Our research team has developed a novel lightweight portable robot-assisted AFO which is capable of detecting walking intentions using sensor feedback of wearer's gait pattern. This study aims to investigate the therapeutic effects of robot-assisted gait training with ankle dorsiflexion assistance. This was a double-blinded randomized controlled trial. Nineteen chronic stroke patients with motor impairment at ankle participated in 20-session robot-assisted gait training for about five weeks, with 30-min over-ground walking and stair ambulation practices. Robot-assisted AFO either provided active powered ankle assistance during swing phase in Robotic Group (n = 9), or torque impedance at ankle joint as passive AFO in Sham Group (n = 10). Functional assessments were performed before and after the 20-session gait training with 3-month Follow-up. Primary outcome measure was gait independency assessed by Functional Ambulatory Category (FAC). Secondary outcome measures were clinical scores including Fugl-Meyer Assessment (FMA), Modified Ashworth Scale (MAS), Berg Balance Scale (BBS), Timed 10-Meter Walk Test (10MWT), Six-minute Walk Test (SMWT), supplemented by gait analysis. All outcome measures were performed in unassisted gait after patients had taken off the robot-assisted AFO. Repeated-measures analysis of covariance was conducted to test the group differences referenced to clinical scores before training. After 20-session robot-assisted gait training with ankle dorsiflexion assistance, the active ankle assistance in Robotic Group induced changes in gait pattern with improved gait independency (all patients FAC ≥ 5 post-training and 3-month follow-up), motor recovery, walking speed, and greater confidence in affected side loading response (vertical ground reaction force + 1.49 N/kg, peak braking force + 0.24 N/kg) with heel strike instead of flat foot touch-down at initial contact (foot tilting + 1.91°). Sham Group reported reduction in affected leg range of motion (ankle dorsiflexion - 2.36° and knee flexion - 8.48°) during swing. Robot-assisted gait training with ankle dorsiflexion assistance could improve gait independency and help stroke patients developing confidence in weight acceptance, but future development of robot-assisted AFO should consider more lightweight and custom-fit design. ClinicalTrials.gov NCT02471248 . Registered 15 June 2015 retrospectively registered.

  6. Biofeedback for robotic gait rehabilitation.

    PubMed

    Lünenburger, Lars; Colombo, Gery; Riener, Robert

    2007-01-23

    Development and increasing acceptance of rehabilitation robots as well as advances in technology allow new forms of therapy for patients with neurological disorders. Robot-assisted gait therapy can increase the training duration and the intensity for the patients while reducing the physical strain for the therapist. Optimal training effects during gait therapy generally depend on appropriate feedback about performance. Compared to manual treadmill therapy, there is a loss of physical interaction between therapist and patient with robotic gait retraining. Thus, it is difficult for the therapist to assess the necessary feedback and instructions. The aim of this study was to define a biofeedback system for a gait training robot and test its usability in subjects without neurological disorders. To provide an overview of biofeedback and motivation methods applied in gait rehabilitation, previous publications and results from our own research are reviewed. A biofeedback method is presented showing how a rehabilitation robot can assess the patients' performance and deliver augmented feedback. For validation, three subjects without neurological disorders walked in a rehabilitation robot for treadmill training. Several training parameters, such as body weight support and treadmill speed, were varied to assess the robustness of the biofeedback calculation to confounding factors. The biofeedback values correlated well with the different activity levels of the subjects. Changes in body weight support and treadmill velocity had a minor effect on the biofeedback values. The synchronization of the robot and the treadmill affected the biofeedback values describing the stance phase. Robot-aided assessment and feedback can extend and improve robot-aided training devices. The presented method estimates the patients' gait performance with the use of the robot's existing sensors, and displays the resulting biofeedback values to the patients and therapists. The therapists can adapt the therapy and give further instructions to the patients. The feedback might help the patients to adapt their movement patterns and to improve their motivation. While it is assumed that these novel methods also improve training efficacy, the proof will only be possible with future in-depth clinical studies.

  7. Effects of obesity on gait pattern in young individuals with Down syndrome.

    PubMed

    Galli, Manuela; Cimolin, Veronica; Rigoldi, Chiara; Condoluci, Claudia; Albertini, Giorgio

    2015-03-01

    In individuals with Down syndrome (DS), the prevalence of obesity is widespread; despite this, there are no experimental studies on the effect of obesity on gait strategy in DS individuals. The aim of this study is to assess the clinical gait analysis of a group of obese individuals with DS and a group of nonobese individuals with DS to determine whether obesity produces a different gait pattern in these participants. In addition, although females and males share a similar mass, they are characterized by different fat distribution and/or accumulation; thus, the presence of differences between females and males within the two DS groups was investigated. Gait analysis data of a group of 78 young individuals with DS and 20 normal-weight participants in the 5-18-year age range were considered. Among DS individuals, 40 were classified as obese (obese DS group), whereas 38 were classified as normal weight (nonobese groups). A three-dimensional gait analysis was carried out using an optoelectronic system, force platforms and video recording. Spatiotemporal, kinematic and kinetic parameters were identified and calculated for each participant. Our results show that most of the parameters were similar in the two groups of DS participants; the only differences were in terms of stance duration, longer in the obese DS group and dorsiflexion ability during the swing phase, which was limited in the obese DS group. The two DS groups were significantly different in terms of ankle stiffness (Ka index): both groups were characterized by reduced values compared with the control group, but the obese group presented lower values with respect to nonobese participants. The data showed that females were characterized by significant modifications of gait pattern compared with males in both groups, in particular, at proximal levels, such as the hip and the pelvis. Our findings indicate that the presence of obesity exerts effects on gait pattern in DS individuals and in particular on ankle joint stiffness. These results may have special clinical relevance; the biomechanical comparison of gait in young obese and nonobese DS individuals may provide a basis for developing either specific or common rehabilitative strategies.

  8. The effects of additional arm weights on arm-swing magnitude and gait patterns in Parkinson's disease.

    PubMed

    Yoon, Jiyeon; Park, Jinse; Park, Kunbo; Jo, Geunyeol; Kim, Haeyu; Jang, Wooyoung; Kim, Ji Sun; Youn, Jinyoung; Oh, Eung Seok; Kim, Hee-Tae; Youm, Chang Hong

    2016-01-01

    Recently, arm facilitation has been interested in gait rehabilitation. However, there have been few studies concerning arm facilitation in patients with Parkinson's disease (PD). The aim of our study was to investigate the effect of increasing arm weights on gait pattern in patients with PD. Twenty-seven patients with PD were enrolled, and they underwent gait analysis using a three-dimensional motion capture system. Sandbags were applied to the distal forearms in all participants. We compared gait parameters including arm swing, pelvic motion, spatiotemporal data, and relative rotational angle between the weighted and unweighted gaits. The total arm-swing amplitude and pelvic rotation were significantly higher when walking with additional arm weights than without arm weights. Cadence, walking speed, stride length, and swing phase were significantly higher, whereas stride time, double-support time, and stance phase were significantly lower, when walking with additional arm weights than without arm weights. We conclude that adding weights to the arm during walking may facilitate arm and pelvic movements, which results in changes to gait patterns. The therapeutic use of additional arm weights could be considered for gait rehabilitation in PD to improve gait impairment. Arm-swing facilitation using weight load improved gait in Parkinson's disease. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  9. Accuracy of clinical observations of push-off during gait after stroke.

    PubMed

    McGinley, Jennifer L; Morris, Meg E; Greenwood, Ken M; Goldie, Patricia A; Olney, Sandra J

    2006-06-01

    To determine the accuracy (criterion-related validity) of real-time clinical observations of push-off in gait after stroke. Criterion-related validity study of gait observations. Rehabilitation hospital in Australia. Eleven participants with stroke and 8 treating physical therapists. Not applicable. Pearson product-moment correlation between physical therapists' observations of push-off during gait and criterion measures of peak ankle power generation from a 3-dimensional motion analysis system. A high correlation was obtained between the observational ratings and the measurements of peak ankle power generation (Pearson r =.98). The standard error of estimation of ankle power generation was .32W/kg. Physical therapists can make accurate real-time clinical observations of push-off during gait following stroke.

  10. Implementation An image processing technique for video motion analysis during the gait cycle canine

    NASA Astrophysics Data System (ADS)

    López, G.; Hernández, J. O.

    2017-01-01

    Nowadays the analyses of human movement, more specifically of the gait have ceased to be a priority for our species. Technological advances and implementations engineering have joined to obtain data and information regarding the gait cycle in another animal species. The aim of this paper is to analyze the canine gait in order to get results that describe the behavior of the limbs during the gait cycle. The research was performed by: 1. Dog training, where it is developed the step of adaptation and trust; 2. Filming gait cycle; 3. Data acquisition, in order to obtain values that describe the motion cycle canine and 4. Results, obtaining the kinematics variables involved in the march. Which are essential to determine the behavior of the limbs, as well as for the development of prosthetic or orthotic. This project was carried out with conventional equipment and using computational tools easily accessible.

  11. An Ambulatory System for Gait Monitoring Based on Wireless Sensorized Insoles

    PubMed Central

    González, Iván; Fontecha, Jesús; Hervás, Ramón; Bravo, José

    2015-01-01

    A new gait phase detection system for continuous monitoring based on wireless sensorized insoles is presented. The system can be used in gait analysis mobile applications, and it is designed for real-time demarcation of gait phases. The system employs pressure sensors to assess the force exerted by each foot during walking. A fuzzy rule-based inference algorithm is implemented on a smartphone and used to detect each of the gait phases based on the sensor signals. Additionally, to provide a solution that is insensitive to perturbations caused by non-walking activities, a probabilistic classifier is employed to discriminate walking forward from other low-level activities, such as turning, walking backwards, lateral walking, etc. The combination of these two algorithms constitutes the first approach towards a continuous gait assessment system, by means of the avoidance of non-walking influences. PMID:26184199

  12. Three-dimensional kinematic analysis of upper and lower limb motion during gait of post-stroke patients

    PubMed Central

    Carmo, A.A.; Kleiner, A.F.R.; Lobo da Costa, P.H.; Barros, R.M.L.

    2012-01-01

    The aim of this study was to analyze the alterations of arm and leg movements of patients during stroke gait. Joint angles of upper and lower limbs and spatiotemporal variables were evaluated in two groups: hemiparetic group (HG, 14 hemiparetic men, 53 ± 10 years) and control group (CG, 7 able-bodied men, 50 ± 4 years). The statistical analysis was based on the following comparisons (P ≤ 0.05): 1) right versus left sides of CG; 2) affected (AF) versus unaffected (UF) sides of HG; 3) CG versus both the affected and unaffected sides of HG, and 4) an intracycle comparison of the kinematic continuous angular variables between HG and CG. This study showed that the affected upper limb motion in stroke gait was characterized by a decreased range of motion of the glenohumeral (HG: 6.3 ± 4.5, CG: 20.1 ± 8.2) and elbow joints (AF: 8.4 ± 4.4, UF: 15.6 ± 7.6) on the sagittal plane and elbow joint flexion throughout the cycle (AF: 68.2 ± 0.4, CG: 46.8 ± 2.7). The glenohumeral joint presented a higher abduction angle (AF: 14.2 ± 1.6, CG: 11.5 ± 4.0) and a lower external rotation throughout the cycle (AF: 4.6 ± 1.2, CG: 22.0 ± 3.0). The lower limbs showed typical alterations of the stroke gait patterns. Thus, the changes in upper and lower limb motion of stroke gait were identified. The description of upper limb motion in stroke gait is new and complements gait analysis. PMID:22473324

  13. Asymmetric pelvic and hip rotation in children with bilateral cerebral palsy: uni- or bilateral femoral derotation osteotomy?

    PubMed

    Niklasch, M; Döderlein, L; Klotz, M C; Braatz, F; Wolf, S I; Dreher, T

    2015-02-01

    Internal rotation gait is common among children with bilateral cerebral palsy. However, despite bilaterally increased femoral anteversion asymmetric internal rotation gait is often found. Femoral derotation osteotomy (FDO) is commonly performed bilaterally. Variable functional outcomes are reported especially in cases with mild internal hip rotation during gait and abnormal preoperative pelvic rotation. A major question is if a unilateral treatment of the more involved side in asymmetric cases leads to a comparable or even superior outcome. One hundred and nine children with spastic bilateral CP treated with FDO with pre- and 1-year postoperative 3D gait analysis were retrospectively collected. The asymmetry was calculated from the preoperative difference between both limbs in hip rotation obtained by 3D gait analysis. Twenty-eight children with asymmetry larger than 20° were selected and classified into two groups, according to whether they obtained a unilateral or bilateral FDO. Preoperative clinical examination and pre- and postoperative hip and pelvic rotation in gait analysis on the more and the less involved side did not differ significantly between both groups. Interestingly, in both groups, hip rotation did not change significantly in less-involved limbs, although intraoperative derotation averaged 25°. After unilateral FDO a significant change in pelvic rotation resulted, whereas this was not found after bilateral FDO. The results of this study suggest that unilateral FDO in children with asymmetric internal rotation gait leads to a comparable functional outcome compared to bilateral treatment. Furthermore, it was shown for the first time that considering the asymmetry has a positive effect on pelvic rotation. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Effects of Exercise on Falls, Balance, and Gait Ability in Parkinson's Disease: A Meta-analysis.

    PubMed

    Shen, Xia; Wong-Yu, Irene S K; Mak, Margaret K Y

    2016-07-01

    Postural instability and falls are complex and disabling features of Parkinson's disease (PD) and respond poorly to anti-Parkinsonian medication. There is an imperative need to evaluate the effectiveness of exercise interventions in enhancing postural stability and decreasing falls in the PD population. The objectives of our study were to determine the effects of exercise training on the enhancement of balance and gait ability and reduction in falls for people with PD and to investigate potential factors contributing to the training effects on balance and gait ability of people with PD. We included 25 randomized control trials of a moderate methodological quality in our meta-analysis. The trials examined the effects of exercise training on balance and gait ability and falls against no intervention and placebo intervention. The results showed positive effects of exercise intervention on enhancing balance and gait performance (Hedges' g = 0.303 over the short-term in 24 studies and 0.419 over the long-term in 12 studies; P < .05) and reducing the fall rate (rate ratio = 0.485 over the short-term in 4 studies and 0.413 over the long-term in 5 studies; P < .05). The longest follow-up duration was 12 months. There was no evidence that training decreased the number of fallers over the short- or long-term (P > .05). The results of our metaregression and subgroup analysis showed that facility-based training produced greater training effects on improving PD participants' balance and gait ability (P < .05). The findings support the application of exercise training to improve balance and gait ability and prevent falls in people with PD. © The Author(s) 2015.

  15. Comparison of a robotic-assisted gait training program with a program of functional gait training for children with cerebral palsy: design and methods of a two group randomized controlled cross-over trial.

    PubMed

    Hilderley, Alicia J; Fehlings, Darcy; Lee, Gloria W; Wright, F Virginia

    2016-01-01

    Enhancement of functional ambulation is a key goal of rehabilitation for children with cerebral palsy (CP) who experience gross motor impairment. Physiotherapy (PT) approaches often involve overground and treadmill-based gait training to promote motor learning, typically as free walking or with body-weight support. Robotic-assisted gait training (RAGT), using a device such as the Lokomat ® Pro, may permit longer training duration, faster and more variable gait speeds, and support walking pattern guidance more than overground/treadmill training to further capitalize on motor learning principles. Single group pre-/post-test studies have demonstrated an association between RAGT and moderate to large improvements in gross motor skills, gait velocity and endurance. A single published randomized controlled trial (RCT) comparing RAGT to a PT-only intervention showed no difference in gait kinematics. However, gross motor function and walking endurance were not evaluated and conclusions were limited by a large PT group drop-out rate. In this two-group cross-over RCT, children are randomly allocated to the RAGT or PT arm (each with twice weekly sessions for eight weeks), with cross-over to the other intervention arm following a six-week break. Both interventions are grounded in motor learning principles with incorporation of individualized mobility-based goals. Sessions are fully operationalized through manualized, menu-based protocols and post-session documentation to enhance internal and external validity. Assessments occur pre/post each intervention arm (four time points total) by an independent assessor. The co-primary outcomes are gross motor functional ability (Gross Motor Function Measure (GMFM-66) and 6-minute walk test), with secondary outcome measures assessing: (a) individualized goals; (b) gait variables and daily walking amounts; and (c) functional abilities, participation and quality of life. Investigators and statisticians are blinded to study group allocation in the analyses, and assessors are blinded to treatment group. The primary analysis will be the pre- to post-test differences (change scores) of the GMFM-66 and 6MWT between RAGT and PT groups. This study is the first RCT comparing RAGT to an active gait-related PT intervention in paediatric CP that addresses gait-related gross motor, participation and individualized outcomes, and as such, is expected to provide comprehensive information as to the potential role of RAGT in clinical practice. Trial registration ClinicalTrials.gov NCT02196298.

  16. A Portable Gait Asymmetry Rehabilitation System for Individuals with Stroke Using a Vibrotactile Feedback.

    PubMed

    Afzal, Muhammad Raheel; Oh, Min-Kyun; Lee, Chang-Hee; Park, Young Sook; Yoon, Jungwon

    2015-01-01

    Gait asymmetry caused by hemiparesis results in reduced gait efficiency and reduced activity levels. In this paper, a portable rehabilitation device is proposed that can serve as a tool in diagnosing gait abnormalities in individuals with stroke and has the capability of providing vibration feedback to help compensate for the asymmetric gait. Force-sensitive resistor (FSR) based insoles are used to detect ground contact and estimate stance time. A controller (Arduino) provides different vibration feedback based on the gait phase measurement. It also allows wireless interaction with a personal computer (PC) workstation using the XBee transceiver module, featuring data logging capabilities for subsequent analysis. Walking trials conducted with healthy young subjects allowed us to observe that the system can influence abnormality in the gait. The results of trials showed that a vibration cue based on temporal information was more effective than intensity information. With clinical experiments conducted for individuals with stroke, significant improvement in gait symmetry was observed with minimal disturbance caused to the balance and gait speed as an effect of the biofeedback. Future studies of the long-term rehabilitation effects of the proposed system and further improvements to the system will result in an inexpensive, easy-to-use, and effective rehabilitation device.

  17. [Development of a gait trainer with regulated servo-drive for rehabilitation of locomotor disabled patients].

    PubMed

    Uhlenbrock, D; Sarkodie-Gyan, T; Reiter, F; Konrad, M; Hesse, S

    1997-01-01

    The aim of the present study was to develop a new gait trainer for the rehabilitation of non-ambulatory patients. For the simulation of the gait phase, we used a commercially available fitness trainer (Fast Track) with two foot plates moving in an alternating fashion and connected to a servo-controlled propulsion system providing the necessary support for the movement depending on the patient's impairment level. To compensate deficient equilibrium reflexes, the patient was suspended in a harness capable of supporting some of his/her weight. Video analysis of gait and the kinesiological EMG were used to assess the pattern of movement and the corresponding muscle activity, which were then evaluated in healthy subjects, spinal cord injured and stroke patients and compared with walking on the flat or on a treadmill. Walking on the gait trainer was characterised by a symmetrical, sinusoidal movement of lower amplitude than in normal gait. The EMG showed a low activity of the tibialis anterior muscle, while the antigravity muscles were clearly activated by the gait trainer during the stance phase. In summary, the new gait trainer generates a symmetrical gait-like movement, promoting weight acceptance in the stance phase, which is important for the restoration of walking ability.

  18. A Portable Gait Asymmetry Rehabilitation System for Individuals with Stroke Using a Vibrotactile Feedback

    PubMed Central

    Afzal, Muhammad Raheel; Oh, Min-Kyun; Lee, Chang-Hee; Park, Young Sook; Yoon, Jungwon

    2015-01-01

    Gait asymmetry caused by hemiparesis results in reduced gait efficiency and reduced activity levels. In this paper, a portable rehabilitation device is proposed that can serve as a tool in diagnosing gait abnormalities in individuals with stroke and has the capability of providing vibration feedback to help compensate for the asymmetric gait. Force-sensitive resistor (FSR) based insoles are used to detect ground contact and estimate stance time. A controller (Arduino) provides different vibration feedback based on the gait phase measurement. It also allows wireless interaction with a personal computer (PC) workstation using the XBee transceiver module, featuring data logging capabilities for subsequent analysis. Walking trials conducted with healthy young subjects allowed us to observe that the system can influence abnormality in the gait. The results of trials showed that a vibration cue based on temporal information was more effective than intensity information. With clinical experiments conducted for individuals with stroke, significant improvement in gait symmetry was observed with minimal disturbance caused to the balance and gait speed as an effect of the biofeedback. Future studies of the long-term rehabilitation effects of the proposed system and further improvements to the system will result in an inexpensive, easy-to-use, and effective rehabilitation device. PMID:26161398

  19. Variability of gait, bilateral coordination, and asymmetry in women with fibromyalgia.

    PubMed

    Heredia-Jimenez, J; Orantes-Gonzalez, E; Soto-Hermoso, V M

    2016-03-01

    To analyze how fibromyalgia affected the variability, asymmetry, and bilateral coordination of gait walking at comfortable and fast speeds. 65 fibromyalgia (FM) patients and 50 healthy women were analyzed. Gait analysis was performed using an instrumented walkway (GAITRite system). Average walking speed, coefficient of variation (CV) of stride length, swing time, and step width data were obtained and bilateral coordination and gait asymmetry were analyzed. FM patients presented significantly lower speeds than the healthy group. FM patients obtained significantly higher values of CV_StrideLength (p=0.04; p<0.001), CV_SwingTime (p<0.001; p<0.001), CV_StepWidth (p=0.004; p<0.001), phase coordination index (p=0.01; p=0.03), and p_CV (p<0.001; p=0.001) than the control group, walking at comfortable or fast speeds. Gait asymmetry only showed significant differences in the fast condition. FM patients walked more slowly and presented a greater variability of gait and worse bilateral coordination than healthy subjects. Gait asymmetry only showed differences in the fast condition. The variability and the bilateral coordination were particularly affected by FM in women. Therefore, variability and bilateral coordination of gait could be analyzed to complement the gait evaluation of FM patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Psychometric evaluation of the adolescent and parent versions of the Gaming Addiction Identification Test (GAIT).

    PubMed

    Vadlin, Sofia; Åslund, Cecilia; Rehn, Mattias; Nilsson, Kent W

    2015-12-01

    The objective of the study is to evaluate the psychometric properties of the Gaming Addiction Identification Test (GAIT) and its parent version (GAIT-P), in a representative community sample of adolescents and parents in Västmanland, Sweden. Self-rated and parent-rated gaming addictive symptoms identified by GAIT and GAIT-P were analyzed for frequency of endorsement, internal consistency, concordance, factor structure, prevalence of Internet gaming disorder (IGD), concurrence with the Gaming Addiction Scale for Adolescents, 7-item version (GAS) and the parent version of GAS (GAS-P), and for sex differences. The 12-month prevalence of IGD was found to be 1.3% with GAIT and 2.4% with GAIT-P. Results also indicate promising psychometric results within this population, with high internal consistency, and high concurrent validity with GAS and GAS-P. Concordance between adolescents and parents ratings was high, although moderate in girls. Although exploratory factor analysis indicated poor model fit, it also indicated unidimensionality and high factor loadings in all analyses. GAIT and GAIT-P are suitable for continued use in measuring gaming addiction in adolescents, and, with the additional two items, they now cover all nine IGD criteria. © 2015 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  1. Inertial Sensor-Based Gait Recognition: A Review

    PubMed Central

    Sprager, Sebastijan; Juric, Matjaz B.

    2015-01-01

    With the recent development of microelectromechanical systems (MEMS), inertial sensors have become widely used in the research of wearable gait analysis due to several factors, such as being easy-to-use and low-cost. Considering the fact that each individual has a unique way of walking, inertial sensors can be applied to the problem of gait recognition where assessed gait can be interpreted as a biometric trait. Thus, inertial sensor-based gait recognition has a great potential to play an important role in many security-related applications. Since inertial sensors are included in smart devices that are nowadays present at every step, inertial sensor-based gait recognition has become very attractive and emerging field of research that has provided many interesting discoveries recently. This paper provides a thorough and systematic review of current state-of-the-art in this field of research. Review procedure has revealed that the latest advanced inertial sensor-based gait recognition approaches are able to sufficiently recognise the users when relying on inertial data obtained during gait by single commercially available smart device in controlled circumstances, including fixed placement and small variations in gait. Furthermore, these approaches have also revealed considerable breakthrough by realistic use in uncontrolled circumstances, showing great potential for their further development and wide applicability. PMID:26340634

  2. Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model.

    PubMed

    Żuk, Magdalena; Pezowicz, Celina

    2015-01-01

    Objective. The purpose of the present work was to assess the validity of a six-degrees-of-freedom gait analysis model based on the ISB recommendation on definitions of joint coordinate systems (ISB 6DOF) through a quantitative comparison with the Helen Hays model (HH) and repeatability assessment. Methods. Four healthy subjects were analysed with both marker sets: an HH marker set and four marker clusters in ISB 6DOF. A navigated pointer was used to indicate the anatomical landmark position in the cluster reference system according to the ISB recommendation. Three gait cycles were selected from the data collected simultaneously for the two marker sets. Results. Two protocols showed good intertrial repeatability, which apart from pelvic rotation did not exceed 2°. The greatest differences between protocols were observed in the transverse plane as well as for knee angles. Knee internal/external rotation revealed the lowest subject-to-subject and interprotocol repeatability and inconsistent patterns for both protocols. Knee range of movement in transverse plane was overestimated for the HH set (the mean is 34°), which could indicate the cross-talk effect. Conclusions. The ISB 6DOF anatomically based protocol enabled full 3D kinematic description of joints according to the current standard with clinically acceptable intertrial repeatability and minimal equipment requirements.

  3. Partial Body Weight-Supported Treadmill Training in Spinocerebellar Ataxia

    PubMed Central

    Martins, Camilla Polonini; Horsczaruk, Carlos Henrique Ramos; da Silva, Débora Cristina Lima; Meira Mainenti, Míriam Raquel; Rodrigues, Erika de Carvalho

    2018-01-01

    Background and Purpose The motor impairments related to gait and balance have a huge impact on the life of individuals with spinocerebellar ataxia (SCA). Here, the aim was to assess the possibility of retraining gait, improving cardiopulmonary capacity, and challenging balance during gait in SCA using a partial body weight support (BWS) and a treadmill. Also, the effects of this training over functionality and quality of life were investigated. Methods Eight SCA patients were engaged in the first stage of the study that focused on gait training and cardiovascular conditioning. From those, five took part in a second stage of the study centered on dynamic balance training during gait. The first and second stages lasted 8 and 10 weeks, respectively, both comprising sessions of 50 min (2 times per week). Results The results showed that gait training using partial BWS significantly increased gait performance, treadmill inclination, duration of exercise, and cardiopulmonary capacity in individuals with SCA. After the second stage, balance improvements were also found. Conclusion Combining gait training and challenging tasks to the postural control system in SCA individuals is viable, well tolerated by patients with SCA, and resulted in changes in capacity for walking and balance. PMID:29535874

  4. Effect of Horseback Riding Simulation Machine Training on Trunk Balance and Gait of Chronic Stroke Patients

    PubMed Central

    Kim, Hyungguen; Her, Jin Gang; Ko, Jooyeon

    2014-01-01

    [Purpose] The purpose of this study was to assess the effect of horseback riding simulation machine training on trunk balance and gait of patients with chronic stroke. [Subjects and Methods] The subjects were 20 patients hospitalized for treatment after being diagnosed with stroke. Horseback riding simulation training was provided for 30 minutes, 5 times a week, for 6 weeks. Trunk balance was assessed using the Trunk Impairment Scale (TIS) and a balance measuring device (Biorescue, RM ingenierie, France), and gait ability was measured using the Functional Gait Assessment (FGA) and a gait analyzer (GAITRite, CIR system Inc., USA). [Results] There were significant changes in movement area, distance and velocity of body sway as measured by the TIS and the balance measuring device, and in gait velocity, cadence, stride length and double limb support as measured by the FGA and gait analyzer. [Conclusion] Horseback riding simulation training improved the trunk balance and gait of chronic stroke patients. This present study provides preliminary objective data for future research, and useful clinical information for physical therapists using horseback riding simulation machines as a treatment modality for patients with chronic stroke. PMID:24567670

  5. The effects of smartphone multitasking on gait and dynamic balance.

    PubMed

    Lee, Jeon Hyeong; Lee, Myoung Hee

    2018-02-01

    [Purpose] This study was performed to analyze the influence of smartphone multitasking on gait and dynamic balance. [Subjects and Methods] The subjects were 19 male and 20 female university students. There were 4 types of gait tasks: General Gait (walking without a task), Task Gait 1 (walking while writing a message), Task Gait 2 (walking while writing a message and listening to music), Task Gait 3 (walking while writing a message and having a conversation). To exclude the learning effect, the order of tasks was randomized. The Zebris FDM-T treadmill system (Zebris Medical GmbH, Germany) was used to measure left and right step length and width, and a 10 m walking test (10MWT) was conducted for gait velocity. In addition, a Timed Up and Go test (TUG) was used to measure dynamic balance. All the tasks were performed 3 times, and the mean of the measured values was analyzed. [Results] There were no statistically significant differences in step length and width. There were statistically significant differences in the 10MWT and TUG tests. [Conclusion] Using a smartphone while walking decreases a person's dynamic balance and walking ability. It is considered that accident rates are higher when using a smartphone.

  6. Gait biometrics under spoofing attacks: an experimental investigation

    NASA Astrophysics Data System (ADS)

    Hadid, Abdenour; Ghahramani, Mohammad; Kellokumpu, Vili; Feng, Xiaoyi; Bustard, John; Nixon, Mark

    2015-11-01

    Gait is a relatively biometric modality which has a precious advantage over other modalities, such as iris and voice, in that it can be easily captured from a distance. Although it has recently become a topic of great interest in biometric research, there has been little investigation into gait spoofing attacks where a person tries to imitate the clothing or walking style of someone else. We recently analyzed for the first time the effects of spoofing attacks on silhouette-based gait biometric systems and showed that it was indeed possible to spoof gait biometric systems by clothing impersonation and the deliberate selection of a target that has a similar build to the attacker. To gain deeper insight into the performance of current gait biometric systems under spoofing attacks, we provide a thorough investigation on how clothing can be used to spoof a target and evaluate the performance of two state-of-the-art recognition methods on a gait spoofing database recorded at the University of Southampton. Furthermore, we describe and evaluate an initial solution coping with gait spoofing attacks. The obtained results are very promising and point out interesting findings which can be used for future investigations.

  7. An apparent contradiction: increasing variability to achieve greater precision?

    PubMed

    Rosenblatt, Noah J; Hurt, Christopher P; Latash, Mark L; Grabiner, Mark D

    2014-02-01

    To understand the relationship between variability of foot placement in the frontal plane and stability of gait patterns, we explored how constraining mediolateral foot placement during walking affects the structure of kinematic variance in the lower-limb configuration space during the swing phase of gait. Ten young subjects walked under three conditions: (1) unconstrained (normal walking), (2) constrained (walking overground with visual guides for foot placement to achieve the measured unconstrained step width) and, (3) beam (walking on elevated beams spaced to achieve the measured unconstrained step width). The uncontrolled manifold analysis of the joint configuration variance was used to quantify two variance components, one that did not affect the mediolateral trajectory of the foot in the frontal plane ("good variance") and one that affected this trajectory ("bad variance"). Based on recent studies, we hypothesized that across conditions (1) the index of the synergy stabilizing the mediolateral trajectory of the foot (the normalized difference between the "good variance" and "bad variance") would systematically increase and (2) the changes in the synergy index would be associated with a disproportionate increase in the "good variance." Both hypotheses were confirmed. We conclude that an increase in the "good variance" component of the joint configuration variance may be an effective method of ensuring high stability of gait patterns during conditions requiring increased control of foot placement, particularly if a postural threat is present. Ultimately, designing interventions that encourage a larger amount of "good variance" may be a promising method of improving stability of gait patterns in populations such as older adults and neurological patients.

  8. Gait functional assessment: Spatio-temporal analysis and classification of barefoot plantar pressure in a group of 11-12-year-old children.

    PubMed

    Latour, Ewa; Latour, Marek; Arlet, Jarosław; Adach, Zdzisław; Bohatyrewicz, Andrzej

    2011-07-01

    Analysis of pedobarographical data requires geometric identification of specific anatomical areas extracted from recorded plantar pressures. This approach has led to ambiguity in measurements that may underlie the inconsistency of conclusions reported in pedobarographical studies. The goal of this study was to design a new analysis method less susceptible to the projection accuracy of anthropometric points and distance estimation, based on rarely used spatio-temporal indices. Six pedobarographic records per person (three per foot) from a group of 60 children aged 11-12 years were obtained and analyzed. The basis of the analysis was a mutual relationship between two spatio-temporal indices created by excursion of the peak pressure point and the center-of-pressure point on the dynamic pedobarogram. Classification of weight-shift patterns was elaborated and performed, and their frequencies of occurrence were assessed. This new method allows an assessment of body weight shift through the plantar pressure surface based on distribution analysis of spatio-temporal indices not affected by the shape of this surface. Analysis of the distribution of the created index confirmed the existence of typical ways of weight shifting through the plantar surface of the foot during gait, as well as large variability of the intrasubject occurrence. This method may serve as the basis for interpretation of foot functional features and may extend the clinical usefulness of pedobarography. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Predictive value of clinical scoring and simplified gait analysis for acetabulum fractures.

    PubMed

    Braun, Benedikt J; Wrona, Julian; Veith, Nils T; Rollman, Mika; Orth, Marcel; Herath, Steven C; Holstein, Jörg H; Pohlemann, Tim

    2016-12-01

    Fractures of the acetabulum show a high, long-term complication rate. The aim of the present study was to determine the predictive value of clinical scoring and standardized, simplified gait analysis on the outcome after these fractures. Forty-one patients with acetabular fractures treated between 2008 and 2013 and available, standardized video recorded aftercare were identified from a prospective database. A visual gait score was used to determine the patients walking abilities 6-m postoperatively. Clinical (Merle d'Aubigne and Postel score, visual analogue scale pain, EQ5d) and radiological scoring (Kellgren-Lawrence score, postoperative computed tomography, and Matta classification) were used to perform correlation and multivariate regression analysis. The average patient age was 48 y (range, 15-82 y), six female patients were included in the study. Mean follow-up was 1.6 y (range, 1-2 y). Moderate correlation between the gait score and outcome (versus EQ5d: r s  = 0.477; versus Merle d'Aubigne: r s  = 0.444; versus Kellgren-Lawrence: r s  = -0.533), as well as high correlation between the Merle d'Aubigne score and outcome were seen (versus EQ5d: r s  = 0.575; versus Merle d'Aubigne: r s  = 0.776; versus Kellgren-Lawrence: r s  = -0.419). Using a multivariate regression model, the 6 m gait score (B = -0.299; P < 0.05) and early osteoarthritis development (B = 1.026; P < 0.05) were determined as predictors of final osteoarthritis. A good fit of the regression model was seen (R 2  = 904). Easy and available clinical scoring (gait score/Merle d'Aubigne) can predict short-term radiological and functional outcome after acetabular fractures with sufficient accuracy. Decisions on further treatment and interventions could be based on simplified gait analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Image based weighted center of proximity versus directly measured knee contact location during simulated gait

    PubMed Central

    Wang, Hongsheng; Chen, Tony; Koff, Matthew F.; Hutchinson, Ian D.; Gilbert, Susannah; Choi, Dan; Warren, Russell F.; Rodeo, Scott A.; Maher, Suzanne A.

    2014-01-01

    To understand the mechanical consequences of knee injury requires a detailed analysis of the effect of that injury on joint contact mechanics during activities of daily living. Three-dimensional (3D) knee joint geometric models have been combined with knee joint kinematics to dynamically estimate the location of joint contact during physiological activities – using a weighted center of proximity (WCoP) method. However, the relationship between the estimated WCoP and the actual location of contact has not been defined. The objective of this study was to assess the relationship between knee joint contact location as estimated using the image-based WCoP method, and a directly measured weighted center of contact (WCoC) method during simulated walking. To achieve this goal, we created knee specific models of six human cadaveric knees from magnetic resonance imaging. All knees were then subjected to physiological loads on a knee simulator intended to mimic gait. Knee joint motion was captured using a motion capture system. Knee joint contact stresses were synchronously recorded using a thin electronic sensor throughout gait, and used to compute WCoC for the medial and lateral plateaus of each knee. WCoP was calculated by combining knee kinematics with the MRI-based knee specific model. Both metrics were compared throughout gait using linear regression. The anteroposterior (AP) location of WCoP was significantly correlated with that of WCoC on both tibial plateaus in all specimens (P < 0.01, 95% confidence interval of Person’s coefficient r > 0), but the correlation was not significant in the mediolateral (ML) direction for 4/6 knees (P > 0.05). Our study demonstrates that while the location of joint contact obtained from 3D knee joint contact model, using the WCoP method, is significantly correlated with the location of actual contact stresses in the AP direction, that relationship is less certain in the ML direction. PMID:24837219

  11. Estimation of Ground Reaction Forces and Moments During Gait Using Only Inertial Motion Capture

    PubMed Central

    Karatsidis, Angelos; Bellusci, Giovanni; Schepers, H. Martin; de Zee, Mark; Andersen, Michael S.; Veltink, Peter H.

    2016-01-01

    Ground reaction forces and moments (GRF&M) are important measures used as input in biomechanical analysis to estimate joint kinetics, which often are used to infer information for many musculoskeletal diseases. Their assessment is conventionally achieved using laboratory-based equipment that cannot be applied in daily life monitoring. In this study, we propose a method to predict GRF&M during walking, using exclusively kinematic information from fully-ambulatory inertial motion capture (IMC). From the equations of motion, we derive the total external forces and moments. Then, we solve the indeterminacy problem during double stance using a distribution algorithm based on a smooth transition assumption. The agreement between the IMC-predicted and reference GRF&M was categorized over normal walking speed as excellent for the vertical (ρ = 0.992, rRMSE = 5.3%), anterior (ρ = 0.965, rRMSE = 9.4%) and sagittal (ρ = 0.933, rRMSE = 12.4%) GRF&M components and as strong for the lateral (ρ = 0.862, rRMSE = 13.1%), frontal (ρ = 0.710, rRMSE = 29.6%), and transverse GRF&M (ρ = 0.826, rRMSE = 18.2%). Sensitivity analysis was performed on the effect of the cut-off frequency used in the filtering of the input kinematics, as well as the threshold velocities for the gait event detection algorithm. This study was the first to use only inertial motion capture to estimate 3D GRF&M during gait, providing comparable accuracy with optical motion capture prediction. This approach enables applications that require estimation of the kinetics during walking outside the gait laboratory. PMID:28042857

  12. Gait cycle analysis: parameters sensitive for functional evaluation of peripheral nerve recovery in rat hind limbs.

    PubMed

    Rui, Jing; Runge, M Brett; Spinner, Robert J; Yaszemski, Michael J; Windebank, Anthony J; Wang, Huan

    2014-10-01

    Video-assisted gait kinetics analysis has been a sensitive method to assess rat sciatic nerve function after injury and repair. However, in conduit repair of sciatic nerve defects, previously reported kinematic measurements failed to be a sensitive indicator because of the inferior recovery and inevitable joint contracture. This study aimed to explore the role of physiotherapy in mitigating joint contracture and to seek motion analysis indices that can sensitively reflect motor function. Data were collected from 26 rats that underwent sciatic nerve transection and conduit repair. Regular postoperative physiotherapy was applied. Parameters regarding step length, phase duration, and ankle angle were acquired and analyzed from video recording of gait kinetics preoperatively and at regular postoperative intervals. Stride length ratio (step length of uninjured foot/step length of injured foot), percent swing of the normal paw (percentage of the total stride duration when the uninjured paw is in the air), propulsion angle (toe-off angle subtracted by midstance angle), and clearance angle (ankle angle change from toe off to midswing) decreased postoperatively comparing with baseline values. The gradual recovery of these measurements had a strong correlation with the post-nerve repair time course. Ankle joint contracture persisted despite rigorous physiotherapy. Parameters acquired from a 2-dimensional motion analysis system, that is, stride length ratio, percent swing of the normal paw, propulsion angle, and clearance angle, could sensitively reflect nerve function impairment and recovery in the rat sciatic nerve conduit repair model despite the existence of joint contractures.

  13. SIAMOC position paper on gait analysis in clinical practice: General requirements, methods and appropriateness. Results of an Italian consensus conference.

    PubMed

    Benedetti, Maria Grazia; Beghi, Ettore; De Tanti, Antonio; Cappozzo, Aurelio; Basaglia, Nino; Cutti, Andrea Giovanni; Cereatti, Andrea; Stagni, Rita; Verdini, Federica; Manca, Mario; Fantozzi, Silvia; Mazzà, Claudia; Camomilla, Valentina; Campanini, Isabella; Castagna, Anna; Cavazzuti, Lorenzo; Del Maestro, Martina; Croce, Ugo Della; Gasperi, Marco; Leo, Tommaso; Marchi, Pia; Petrarca, Maurizio; Piccinini, Luigi; Rabuffetti, Marco; Ravaschio, Andrea; Sawacha, Zimi; Spolaor, Fabiola; Tesio, Luigi; Vannozzi, Giuseppe; Visintin, Isabella; Ferrarin, Maurizio

    2017-10-01

    Gait analysis is recognized as a useful assessment tool in the field of human movement research. However, doubts remain on its real effectiveness as a clinical tool, i.e. on its capability to change the diagnostic-therapeutic practice. In particular, the conditions in which evidence of a favorable cost-benefit ratio is found and the methodology for properly conducting and interpreting the exam are not identified clearly. To provide guidelines for the use of Gait Analysis in the context of rehabilitation medicine, SIAMOC (the Italian Society of Clinical Movement Analysis) promoted a National Consensus Conference which was held in Bologna on September 14th, 2013. The resulting recommendations were the result of a three-stage process entailing i) the preparation of working documents on specific open issues, ii) the holding of the consensus meeting, and iii) the drafting of consensus statements by an external Jury. The statements were formulated based on scientific evidence or experts' opinion, when the quality/quantity of the relevant literature was deemed insufficient. The aim of this work is to disseminate the consensus statements. These are divided into 13 questions grouped in three areas of interest: 1) General requirements and management, 2) Methodological and instrumental issues, and 3) Scientific evidence and clinical appropriateness. SIAMOC hopes that this document will contribute to improve clinical practice and help promoting further research in the field. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Non-linear dynamics of human locomotion: effects of rhythmic auditory cueing on local dynamic stability.

    PubMed

    Terrier, Philippe; Dériaz, Olivier

    2013-01-01

    It has been observed that times series of gait parameters [stride length (SL), stride time (ST), and stride speed (SS)], exhibit long-term persistence and fractal-like properties. Synchronizing steps with rhythmic auditory stimuli modifies the persistent fluctuation pattern to anti-persistence. Another non-linear method estimates the degree of resilience of gait control to small perturbations, i.e., the local dynamic stability (LDS). The method makes use of the maximal Lyapunov exponent, which estimates how fast a non-linear system embedded in a reconstructed state space (attractor) diverges after an infinitesimal perturbation. We propose to use an instrumented treadmill to simultaneously measure basic gait parameters (time series of SL, ST, and SS from which the statistical persistence among consecutive strides can be assessed), and the trajectory of the center of pressure (from which the LDS can be estimated). In 20 healthy participants, the response to rhythmic auditory cueing (RAC) of LDS and of statistical persistence [assessed with detrended fluctuation analysis (DFA)] was compared. By analyzing the divergence curves, we observed that long-term LDS (computed as the reverse of the average logarithmic rate of divergence between the 4th and the 10th strides downstream from nearest neighbors in the reconstructed attractor) was strongly enhanced (relative change +73%). That is likely the indication of a more dampened dynamics. The change in short-term LDS (divergence over one step) was smaller (+3%). DFA results (scaling exponents) confirmed an anti-persistent pattern in ST, SL, and SS. Long-term LDS (but not short-term LDS) and scaling exponents exhibited a significant correlation between them (r = 0.7). Both phenomena probably result from the more conscious/voluntary gait control that is required by RAC. We suggest that LDS and statistical persistence should be used to evaluate the efficiency of cueing therapy in patients with neurological gait disorders.

  15. Complex pattern of interaction between in utero hypoxia-ischemia and intra-amniotic inflammation disrupts brain development and motor function

    PubMed Central

    2014-01-01

    Background Infants born preterm commonly suffer from a combination of hypoxia-ischemia (HI) and infectious perinatal inflammatory insults that lead to cerebral palsy, cognitive delay, behavioral issues and epilepsy. Using a novel rat model of combined late gestation HI and lipopolysaccharide (LPS)-induced inflammation, we tested our hypothesis that inflammation from HI and LPS differentially affects gliosis, white matter development and motor impairment during the first postnatal month. Methods Pregnant rats underwent laparotomy on embryonic day 18 and transient systemic HI (TSHI) and/or intra-amniotic LPS injection. Shams received laparotomy and anesthesia only. Pups were born at term. Immunohistochemistry with stereological estimates was performed to assess regional glial loads, and western blots were performed for protein expression. Erythropoietin ligand and receptor levels were quantified using quantitative PCR. Digigait analysis detected gait deficits. Statistical analysis was performed with one-way analysis of variance and post-hoc Bonferonni correction. Results Microglial and astroglial immunolabeling are elevated in TSHI + LPS fimbria at postnatal day 2 compared to sham (both P < 0.03). At postnatal day 15, myelin basic protein expression is reduced by 31% in TSHI + LPS pups compared to shams (P < 0.05). By postnatal day 28, white matter injury shifts from the acute injury pattern to a chronic injury pattern in TSHI pups only. Both myelin basic protein expression (P < 0.01) and the phosphoneurofilament/neurofilament ratio, a marker of axonal dysfunction, are reduced in postnatal day 28 TSHI pups (P < 0.001). Erythropoietin ligand to receptor ratios differ between brains exposed to TSHI and LPS. Gait analyses reveal that all groups (TSHI, LPS and TSHI + LPS) are ataxic with deficits in stride, paw placement, gait consistency and coordination (all P < 0.001). Conclusions Prenatal TSHI and TSHI + LPS lead to different patterns of injury with respect to myelination, axon integrity and gait deficits. Dual injury leads to acute alterations in glial response and cellular inflammation, while TSHI alone causes more prominent chronic white matter and axonal injury. Both injuries cause significant gait deficits. Further study will contribute to stratification of injury mechanisms in preterm infants, and guide the use of promising therapeutic interventions. PMID:25082427

  16. Spatial-dependence recurrence sample entropy

    NASA Astrophysics Data System (ADS)

    Pham, Tuan D.; Yan, Hong

    2018-03-01

    Measuring complexity in terms of the predictability of time series is a major area of research in science and engineering, and its applications are spreading throughout many scientific disciplines, where the analysis of physiological signals is perhaps the most widely reported in literature. Sample entropy is a popular measure for quantifying signal irregularity. However, the sample entropy does not take sequential information, which is inherently useful, into its calculation of sample similarity. Here, we develop a method that is based on the mathematical principle of the sample entropy and enables the capture of sequential information of a time series in the context of spatial dependence provided by the binary-level co-occurrence matrix of a recurrence plot. Experimental results on time-series data of the Lorenz system, physiological signals of gait maturation in healthy children, and gait dynamics in Huntington's disease show the potential of the proposed method.

  17. Improved gait after repetitive locomotor training in children with cerebral palsy.

    PubMed

    Smania, Nicola; Bonetti, Paola; Gandolfi, Marialuisa; Cosentino, Alessandro; Waldner, Andreas; Hesse, Stefan; Werner, Cordula; Bisoffi, Giulia; Geroin, Christian; Munari, Daniele

    2011-02-01

    The aim of this study was to evaluate the effectiveness of repetitive locomotor training with an electromechanical gait trainer in children with cerebral palsy. In this randomized controlled trial, 18 ambulatory children with diplegic or tetraplegic cerebral palsy were randomly assigned to an experimental group or a control group. The experimental group received 30 mins of repetitive locomotor training with an applied technology (Gait Trainer GT I) plus 10 mins of passive joint mobilization and stretching exercises. The control group received 40 mins of conventional physiotherapy. Each subject underwent a total of 10 treatment sessions over a 2-wk period. Performance on the 10-m walk test, 6-min walk test, WeeFIM scale, and gait analysis was evaluated by a blinded rater before and after treatment and at 1-mo follow-up. The experimental group showed significant posttreatment improvement on the 10-m walk test, 6-min walk test, hip kinematics, gait speed, and step length, all of which were maintained at the 1-mo follow-up assessment. No significant changes in performance parameters were observed in the control group. Repetitive locomotor training with an electromechanical gait trainer may improve gait velocity, endurance, spatiotemporal, and kinematic gait parameters in patients with cerebral palsy.

  18. Normal human gait patterns in Peruvian individuals: an exploratory assessment using VICON motion capture system

    NASA Astrophysics Data System (ADS)

    Dongo, R.; Moscoso, M.; Callupe, R.; Pajaya, J.; Elías, D.

    2017-11-01

    Gait analysis is of clinical relevance for clinicians. However, normal gait patterns used in foreign literature could be different from local individuals. The aim of this study was to determine the normal gait patterns and parameters of Peruvian individuals in order to have a local referent for clinical assessments and making diagnosis and treatment Peruvian people with lower motor neuron injuries. A descriptive study with 34 subjects was conducted to assess their gait cycle. VICON® cameras were used to capture body movements. For the analyses, we calculated spatiotemporal gait parameters and average angles of displacement of the hip, knee, and ankle joints with their respective 95% confidence intervals. The results showed gait speed was 0.58m/s, cadence was 102.1steps/min, and the angular displacement of the hip, knee and ankle joints were all lower than those described in the literature. In the graphs, gait cycles were close to those reported in previous studies, but the parameters of speed, cadence and angles of displacements are lower than the ones shown in the literature. These results could be used as a better reference pattern in the clinical setting.

  19. Biofeedback for robotic gait rehabilitation

    PubMed Central

    Lünenburger, Lars; Colombo, Gery; Riener, Robert

    2007-01-01

    Background Development and increasing acceptance of rehabilitation robots as well as advances in technology allow new forms of therapy for patients with neurological disorders. Robot-assisted gait therapy can increase the training duration and the intensity for the patients while reducing the physical strain for the therapist. Optimal training effects during gait therapy generally depend on appropriate feedback about performance. Compared to manual treadmill therapy, there is a loss of physical interaction between therapist and patient with robotic gait retraining. Thus, it is difficult for the therapist to assess the necessary feedback and instructions. The aim of this study was to define a biofeedback system for a gait training robot and test its usability in subjects without neurological disorders. Methods To provide an overview of biofeedback and motivation methods applied in gait rehabilitation, previous publications and results from our own research are reviewed. A biofeedback method is presented showing how a rehabilitation robot can assess the patients' performance and deliver augmented feedback. For validation, three subjects without neurological disorders walked in a rehabilitation robot for treadmill training. Several training parameters, such as body weight support and treadmill speed, were varied to assess the robustness of the biofeedback calculation to confounding factors. Results The biofeedback values correlated well with the different activity levels of the subjects. Changes in body weight support and treadmill velocity had a minor effect on the biofeedback values. The synchronization of the robot and the treadmill affected the biofeedback values describing the stance phase. Conclusion Robot-aided assessment and feedback can extend and improve robot-aided training devices. The presented method estimates the patients' gait performance with the use of the robot's existing sensors, and displays the resulting biofeedback values to the patients and therapists. The therapists can adapt the therapy and give further instructions to the patients. The feedback might help the patients to adapt their movement patterns and to improve their motivation. While it is assumed that these novel methods also improve training efficacy, the proof will only be possible with future in-depth clinical studies. PMID:17244363

  20. Gait characteristics and their discriminative power in geriatric patients with and without cognitive impairment.

    PubMed

    Kikkert, Lisette H J; Vuillerme, Nicolas; van Campen, Jos P; Appels, Bregje A; Hortobágyi, Tibor; Lamoth, Claudine J C

    2017-08-15

    A detailed gait analysis (e.g., measures related to speed, self-affinity, stability, and variability) can help to unravel the underlying causes of gait dysfunction, and identify cognitive impairment. However, because geriatric patients present with multiple conditions that also affect gait, results from healthy old adults cannot easily be extrapolated to geriatric patients. Hence, we (1) quantified gait outcomes based on dynamical systems theory, and (2) determined their discriminative power in three groups: healthy old adults, geriatric patients with- and geriatric patients without cognitive impairment. For the present cross-sectional study, 25 healthy old adults recruited from community (65 ± 5.5 years), and 70 geriatric patients with (n = 39) and without (n = 31) cognitive impairment from the geriatric dayclinic of the MC Slotervaart hospital in Amsterdam (80 ± 6.6 years) were included. Participants walked for 3 min during single- and dual-tasking at self-selected speed while 3D trunk accelerations were registered with an IPod touch G4. We quantified 23 gait outcomes that reflect multiple gait aspects. A multivariate model was built using Partial Least Square- Discriminant Analysis (PLS-DA) that best modelled participant group from gait outcomes. For single-task walking, the PLS-DA model consisted of 4 Latent Variables that explained 63 and 41% of the variance in gait outcomes and group, respectively. Outcomes related to speed, regularity, predictability, and stability of trunk accelerations revealed with the highest discriminative power (VIP > 1). A high proportion of healthy old adults (96 and 93% for single- and dual-task, respectively) was correctly classified based on the gait outcomes. The discrimination of geriatric patients with and without cognitive impairment was poor, with 57% (single-task) and 64% (dual-task) of the patients misclassified. While geriatric patients vs. healthy old adults walked slower, and less regular, predictable, and stable, we found no differences in gait between geriatric patients with and without cognitive impairment. The effects of multiple comorbidities on geriatric patients' gait possibly causes a 'floor-effect', with no room for further deterioration when patients develop cognitive impairment. An accurate identification of cognitive status thus necessitates a multifactorial approach.

  1. A Microsoft Kinect-Based Point-of-Care Gait Assessment Framework for Multiple Sclerosis Patients.

    PubMed

    Gholami, Farnood; Trojan, Daria A; Kovecses, Jozsef; Haddad, Wassim M; Gholami, Behnood

    2017-09-01

    Gait impairment is a prevalent and important difficulty for patients with multiple sclerosis (MS), a common neurological disorder. An easy to use tool to objectively evaluate gait in MS patients in a clinical setting can assist clinicians to perform an objective assessment. The overall objective of this study is to develop a framework to quantify gait abnormalities in MS patients using the Microsoft Kinect for the Windows sensor; an inexpensive, easy to use, portable camera. Specifically, we aim to evaluate its feasibility for utilization in a clinical setting, assess its reliability, evaluate the validity of gait indices obtained, and evaluate a novel set of gait indices based on the concept of dynamic time warping. In this study, ten ambulatory MS patients, and ten age and sex-matched normal controls were studied at one session in a clinical setting with gait assessment using a Kinect camera. The expanded disability status scale (EDSS) clinical ambulation score was calculated for the MS subjects, and patients completed the Multiple Sclerosis walking scale (MSWS). Based on this study, we established the potential feasibility of using a Microsoft Kinect camera in a clinical setting. Seven out of the eight gait indices obtained using the proposed method were reliable with intraclass correlation coefficients ranging from 0.61 to 0.99. All eight MS gait indices were significantly different from those of the controls (p-values less than 0.05). Finally, seven out of the eight MS gait indices were correlated with the objective and subjective gait measures (Pearson's correlation coefficients greater than 0.40). This study shows that the Kinect camera is an easy to use tool to assess gait in MS patients in a clinical setting.

  2. Spontaneous Symmetry-Breaking in a Network Model for Quadruped Locomotion

    NASA Astrophysics Data System (ADS)

    Stewart, Ian

    2017-12-01

    Spontaneous symmetry-breaking proves a mechanism for pattern generation in legged locomotion of animals. The basic timing patterns of animal gaits are produced by a network of spinal neurons known as a Central Pattern Generator (CPG). Animal gaits are primarily characterized by phase differences between leg movements in a periodic gait cycle. Many different gaits occur, often having spatial or spatiotemporal symmetries. A natural way to explain gait patterns is to assume that the CPG is symmetric, and to classify the possible symmetry-breaking periodic motions. Pinto and Golubitsky have discussed a four-node model CPG network for biped gaits with ℤ2 × ℤ2 symmetry, classifying the possible periodic states that can arise. A more specific rate model with this structure has been analyzed in detail by Stewart. Here we extend these methods to quadruped gaits, using an eight-node network with ℤ4 × ℤ2 symmetry proposed by Golubitsky and coworkers. We formulate a rate model and calculate how the first steady or Hopf bifurcation depends on its parameters, which represent four connection strengths. The calculations involve a distinction between “real” gaits with one or two phase shifts (pronk, bound, pace, trot) and “complex” gaits with four phase shifts (forward and reverse walk, forward and reverse buck). The former correspond to real eigenvalues of the connection matrix, the latter to complex conjugate pairs. The partition of parameter space according to the first bifurcation, ignoring complex gaits, is described explicitly. The complex gaits introduce further complications, not yet fully understood. All eight gaits can occur as the first bifurcation from a fully synchronous equilibrium, for suitable parameters, and numerical simulations indicate that they can be asymptotically stable.

  3. Ankle joint function during walking in tophaceous gout: A biomechanical gait analysis study.

    PubMed

    Carroll, Matthew; Boocock, Mark; Dalbeth, Nicola; Stewart, Sarah; Frampton, Christopher; Rome, Keith

    2018-04-17

    The foot and ankle are frequently affected in tophaceous gout, yet kinematic and kinetic changes in this region during gait are unknown. The aim of the study was to evaluate ankle biomechanical characteristics in people with tophaceous gout using three-dimensional gait analysis. Twenty-four participants with tophaceous gout were compared with 24 age-and sex-matched control participants. A 9-camera motion analysis system and two floor-mounted force plates were used to calculate kinematic and kinetic parameters. Peak ankle joint angular velocity was significantly decreased in participants with gout (P < 0.01). No differences were found for ankle ROM in either the sagittal (P = 0.43) or frontal planes (P = 0.08). No differences were observed between groups for peak ankle joint power (P = 0.41), peak ankle joint force (P = 0.25), peak ankle joint moment (P = 0.16), timing for peak ankle joint force (P = 0.81), or timing for peak ankle joint moment (P = 0.16). Three dimensional gait analysis demonstrated that ankle joint function does not change in people with gout. People with gout demonstrated a reduced peak ankle joint angular velocity which may reflect gait-limiting factors and adaptations from the high levels of foot pain, impairment and disability experienced by this population. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Classifying Lower Extremity Muscle Fatigue during Walking using Machine Learning and Inertial Sensors

    PubMed Central

    Zhang, Jian; Lockhart, Thurmon E.; Soangra, Rahul

    2013-01-01

    Fatigue in lower extremity musculature is associated with decline in postural stability, motor performance and alters normal walking patterns in human subjects. Automated recognition of lower extremity muscle fatigue condition may be advantageous in early detection of fall and injury risks. Supervised machine learning methods such as Support Vector Machines (SVM) have been previously used for classifying healthy and pathological gait patterns and also for separating old and young gait patterns. In this study we explore the classification potential of SVM in recognition of gait patterns utilizing an inertial measurement unit associated with lower extremity muscular fatigue. Both kinematic and kinetic gait patterns of 17 participants (29±11 years) were recorded and analyzed in normal and fatigued state of walking. Lower extremities were fatigued by performance of a squatting exercise until the participants reached 60% of their baseline maximal voluntary exertion level. Feature selection methods were used to classify fatigue and no-fatigue conditions based on temporal and frequency information of the signals. Additionally, influences of three different kernel schemes (i.e., linear, polynomial, and radial basis function) were investigated for SVM classification. The results indicated that lower extremity muscle fatigue condition influenced gait and loading responses. In terms of the SVM classification results, an accuracy of 96% was reached in distinguishing the two gait patterns (fatigue and no-fatigue) within the same subject using the kinematic, time and frequency domain features. It is also found that linear kernel and RBF kernel were equally good to identify intra-individual fatigue characteristics. These results suggest that intra-subject fatigue classification using gait patterns from an inertial sensor holds considerable potential in identifying “at-risk” gait due to muscle fatigue. PMID:24081829

  5. EEG and Neuronal Activity Topography analysis can predict effectiveness of shunt operation in idiopathic normal pressure hydrocephalus patients☆

    PubMed Central

    Aoki, Yasunori; Kazui, Hiroaki; Tanaka, Toshihisa; Ishii, Ryouhei; Wada, Tamiki; Ikeda, Shunichiro; Hata, Masahiro; Canuet, Leonides; Musha, Toshimitsu; Matsuzaki, Haruyasu; Imajo, Kaoru; Yoshiyama, Kenji; Yoshida, Tetsuhiko; Shimizu, Yoshiro; Nomura, Keiko; Iwase, Masao; Takeda, Masatoshi

    2013-01-01

    Idiopathic normal pressure hydrocephalus (iNPH) is a neuropsychiatric syndrome characterized by gait disturbance, cognitive impairment and urinary incontinence that affect elderly individuals. These symptoms can potentially be reversed by cerebrospinal fluid (CSF) drainage or shunt operation. Prior to shunt operation, drainage of a small amount of CSF or “CSF tapping” is usually performed to ascertain the effect of the operation. Unfortunately, conventional neuroimaging methods such as single photon emission computed tomography (SPECT) and functional magnetic resonance imaging (fMRI), as well as electroencephalogram (EEG) power analysis seem to have failed to detect the effect of CSF tapping on brain function. In this work, we propose the use of Neuronal Activity Topography (NAT) analysis, which calculates normalized power variance (NPV) of EEG waves, to detect cortical functional changes induced by CSF tapping in iNPH. Based on clinical improvement by CSF tapping and shunt operation, we classified 24 iNPH patients into responders (N = 11) and nonresponders (N = 13), and performed both EEG power analysis and NAT analysis. We also assessed correlations between changes in NPV and changes in functional scores on gait and cognition scales before and after CSF tapping. NAT analysis showed that after CSF tapping there was a significant decrease in alpha NPV at the medial frontal cortex (FC) (Fz) in responders, while nonresponders exhibited an increase in alpha NPV at the right dorsolateral prefrontal cortex (DLPFC) (F8). Furthermore, we found correlations between cortical functional changes and clinical symptoms. In particular, delta and alpha NPV changes in the left-dorsal FC (F3) correlated with changes in gait status, while alpha and beta NPV changes in the right anterior prefrontal cortex (PFC) (Fp2) and left DLPFC (F7) as well as alpha NPV changes in the medial FC (Fz) correlated with changes in gait velocity. In addition, alpha NPV changes in the right DLPFC (F8) correlated with changes in WMS-R Mental Control scores in iNPH patients. An additional analysis combining the changes in values of alpha NPV over the left-dorsal FC (∆alpha-F3-NPV) and the medial FC (∆alpha-Fz-NPV) induced by CSF tapping (cut-off value of ∆alpha-F3-NPV + ∆alpha-Fz-NPV = 0), could correctly identified “shunt responders” and “shunt nonresponders” with a positive predictive value of 100% (10/10) and a negative predictive value of 66% (2/3). In contrast, EEG power spectral analysis showed no function related changes in cortical activity at the frontal cortex before and after CSF tapping. These results indicate that the clinical changes in gait and response suppression induced by CSF tapping in iNPH patients manifest as NPV changes, particularly in the alpha band, rather than as EEG power changes. Our findings suggest that NAT analysis can detect CSF tapping-induced functional changes in cortical activity, in a way that no other neuroimaging methods have been able to do so far, and can predict clinical response to shunt operation in patients with iNPH. PMID:24273735

  6. EEG and Neuronal Activity Topography analysis can predict effectiveness of shunt operation in idiopathic normal pressure hydrocephalus patients.

    PubMed

    Aoki, Yasunori; Kazui, Hiroaki; Tanaka, Toshihisa; Ishii, Ryouhei; Wada, Tamiki; Ikeda, Shunichiro; Hata, Masahiro; Canuet, Leonides; Musha, Toshimitsu; Matsuzaki, Haruyasu; Imajo, Kaoru; Yoshiyama, Kenji; Yoshida, Tetsuhiko; Shimizu, Yoshiro; Nomura, Keiko; Iwase, Masao; Takeda, Masatoshi

    2013-01-01

    Idiopathic normal pressure hydrocephalus (iNPH) is a neuropsychiatric syndrome characterized by gait disturbance, cognitive impairment and urinary incontinence that affect elderly individuals. These symptoms can potentially be reversed by cerebrospinal fluid (CSF) drainage or shunt operation. Prior to shunt operation, drainage of a small amount of CSF or "CSF tapping" is usually performed to ascertain the effect of the operation. Unfortunately, conventional neuroimaging methods such as single photon emission computed tomography (SPECT) and functional magnetic resonance imaging (fMRI), as well as electroencephalogram (EEG) power analysis seem to have failed to detect the effect of CSF tapping on brain function. In this work, we propose the use of Neuronal Activity Topography (NAT) analysis, which calculates normalized power variance (NPV) of EEG waves, to detect cortical functional changes induced by CSF tapping in iNPH. Based on clinical improvement by CSF tapping and shunt operation, we classified 24 iNPH patients into responders (N = 11) and nonresponders (N = 13), and performed both EEG power analysis and NAT analysis. We also assessed correlations between changes in NPV and changes in functional scores on gait and cognition scales before and after CSF tapping. NAT analysis showed that after CSF tapping there was a significant decrease in alpha NPV at the medial frontal cortex (FC) (Fz) in responders, while nonresponders exhibited an increase in alpha NPV at the right dorsolateral prefrontal cortex (DLPFC) (F8). Furthermore, we found correlations between cortical functional changes and clinical symptoms. In particular, delta and alpha NPV changes in the left-dorsal FC (F3) correlated with changes in gait status, while alpha and beta NPV changes in the right anterior prefrontal cortex (PFC) (Fp2) and left DLPFC (F7) as well as alpha NPV changes in the medial FC (Fz) correlated with changes in gait velocity. In addition, alpha NPV changes in the right DLPFC (F8) correlated with changes in WMS-R Mental Control scores in iNPH patients. An additional analysis combining the changes in values of alpha NPV over the left-dorsal FC (∆alpha-F3-NPV) and the medial FC (∆alpha-Fz-NPV) induced by CSF tapping (cut-off value of ∆alpha-F3-NPV + ∆alpha-Fz-NPV = 0), could correctly identified "shunt responders" and "shunt nonresponders" with a positive predictive value of 100% (10/10) and a negative predictive value of 66% (2/3). In contrast, EEG power spectral analysis showed no function related changes in cortical activity at the frontal cortex before and after CSF tapping. These results indicate that the clinical changes in gait and response suppression induced by CSF tapping in iNPH patients manifest as NPV changes, particularly in the alpha band, rather than as EEG power changes. Our findings suggest that NAT analysis can detect CSF tapping-induced functional changes in cortical activity, in a way that no other neuroimaging methods have been able to do so far, and can predict clinical response to shunt operation in patients with iNPH.

  7. Gait symmetry and regularity in transfemoral amputees assessed by trunk accelerations

    PubMed Central

    2010-01-01

    Background The aim of this study was to evaluate a method based on a single accelerometer for the assessment of gait symmetry and regularity in subjects wearing lower limb prostheses. Methods Ten transfemoral amputees and ten healthy control subjects were studied. For the purpose of this study, subjects wore a triaxial accelerometer on their thorax, and foot insoles. Subjects were asked to walk straight ahead for 70 m at their natural speed, and at a lower and faster speed. Indices of step and stride regularity (Ad1 and Ad2, respectively) were obtained by the autocorrelation coefficients computed from the three acceleration components. Step and stride durations were calculated from the plantar pressure data and were used to compute two reference indices (SI1 and SI2) for step and stride regularity. Results Regression analysis showed that both Ad1 well correlates with SI1 (R2 up to 0.74), and Ad2 well correlates with SI2 (R2 up to 0.52). A ROC analysis showed that Ad1 and Ad2 has generally a good sensitivity and specificity in classifying amputee's walking trial, as having a normal or a pathologic step or stride regularity as defined by means of the reference indices SI1 and SI2. In particular, the antero-posterior component of Ad1 and the vertical component of Ad2 had a sensitivity of 90.6% and 87.2%, and a specificity of 92.3% and 81.8%, respectively. Conclusions The use of a simple accelerometer, whose components can be analyzed by the autocorrelation function method, is adequate for the assessment of gait symmetry and regularity in transfemoral amputees. PMID:20085653

  8. Use of the Gait Deviation Index for the Assessment of Gastrocnemius Fascia Lengthening in Children with Cerebral Palsy

    ERIC Educational Resources Information Center

    Cimolin, Veronica; Galli, Manuela; Vimercati, Sara Laura; Albertini, Giorgio

    2011-01-01

    Gait analysis (GA) is widely used for clinical evaluations and it is recognized as a central element in the quantitative evaluation of gait, in the planning of treatments and in the pre vs. post intervention evaluations in children with Cerebral Palsy (CP). Otherwise, GA produces a large volume of data and there is the clinical need to provide…

  9. Effects of circular gait training on balance, balance confidence in patients with stroke: a pilot study.

    PubMed

    Park, Shin-Kyu; Kim, Sung-Jin; Yoon, Tak Yong; Lee, Suk-Min

    2018-05-01

    [Purpose] This study aimed to investigate the effects of circular gait training on balance and balance confidence in patients with stroke. [Subjects and Methods] Fifteen patients with stroke were randomly divided into either the circular gait training (CGT) group (n=8) or the straight gait training (SGT) group (n=7). Both groups had conventional therapy that adhered to the neurodevelopmental treatment (NDT) approach, for 30 min. In addition, the CGT group performed circular gait training, and the SGT group practiced straight gait training for 30 min. Each intervention was applied for 1 h, 5 days a week, for 2 weeks. Berg Balance Scale (BBS), Timed Up and Go (TUG) test, and Activities-specific Balance Confidence (ABC) scale were used to test balance and balance confidence. [Results] After the intervention, both groups showed significant increases in balance and balance confidence. Significant improvements in the balance of the CGT group compared with the SGT group were observed at post-assessment. [Conclusion] This study showed that circular gait training significantly improves balance in patients with stroke.

  10. Full Body Gait Analysis May Improve Diagnostic Discrimination Between Hereditary Spastic Paraplegia and Spastic Diplegia: A Preliminary Study

    ERIC Educational Resources Information Center

    Bonnefoy-Mazure, A.; Turcot, K.; Kaelin, A.; De Coulon, G.; Armand, S.

    2013-01-01

    Hereditary spastic paraplegia (HSP) and spastic diplegia (SD) patients share a strong clinical resemblance. Thus, HSP patients are frequently misdiagnosed with a mild form of SD. Clinical gait analysis (CGA) has been highlighted as a possible tool to support the differential diagnosis of HSP and SD. Previous analysis has focused on the lower-body…

  11. Stereophotogrammetrie Mass Distribution Parameter Determination Of The Lower Body Segments For Use In Gait Analysis

    NASA Astrophysics Data System (ADS)

    Sheffer, Daniel B.; Schaer, Alex R.; Baumann, Juerg U.

    1989-04-01

    Inclusion of mass distribution information in biomechanical analysis of motion is a requirement for the accurate calculation of external moments and forces acting on the segmental joints during locomotion. Regression equations produced from a variety of photogrammetric, anthropometric and cadaeveric studies have been developed and espoused in literature. Because of limitations in the accuracy of predicted inertial properties based on the application of regression equation developed on one population and then applied on a different study population, the employment of a measurement technique that accurately defines the shape of each individual subject measured is desirable. This individual data acquisition method is especially needed when analyzing the gait of subjects with large differences in their extremity geo-metry from those considered "normal", or who may possess gross asymmetries in shape in their own contralateral limbs. This study presents the photogrammetric acquisition and data analysis methodology used to assess the inertial tensors of two groups of subjects, one with spastic diplegic cerebral palsy and the other considered normal.

  12. Quantifying gait deviations in individuals with rheumatoid arthritis using the Gait Deviation Index.

    PubMed

    Esbjörnsson, A-C; Rozumalski, A; Iversen, M D; Schwartz, M H; Wretenberg, P; Broström, E W

    2014-01-01

    In this study we evaluated the usability of the Gait Deviation Index (GDI), an index that summarizes the amount of deviation in movement from a standard norm, in adults with rheumatoid arthritis (RA). The aims of the study were to evaluate the ability of the GDI to identify gait deviations, assess inter-trial repeatability, and examine the relationship between the GDI and walking speed, physical disability, and pain. Sixty-three adults with RA and 59 adults with typical gait patterns were included in this retrospective case-control study. Following a three-dimensional gait analysis (3DGA), representative gait cycles were selected and GDI scores calculated. To evaluate the effect of walking speed, GDI scores were calculated using both a free-speed and a speed-matched reference set. Physical disability was assessed using the Health Assessment Questionnaire (HAQ) and subjects rated their pain during walking. Adults with RA had significantly increased gait deviations compared to healthy individuals, as shown by lower GDI scores [87.9 (SD = 8.7) vs. 99.4 (SD = 8.3), p < 0.001]. This difference was also seen when adjusting for walking speed [91.7 (SD = 9.0) vs. 99.9 (SD = 8.6), p < 0.001]. It was estimated that a change of ≥ 5 GDI units was required to account for natural variation in gait. There was no evident relationship between GDI and low/high RA-related physical disability and pain. The GDI seems to useful for identifying and summarizing gait deviations in individuals with RA. Thus, we consider that the GDI provides an overall measure of gait deviation that may reflect lower extremity pathology and may help clinicians to understand the impact of RA on gait dynamics.

  13. Gait outcome following outpatient physiotherapy based on the Bobath concept in people post stroke.

    PubMed

    Lennon, Sheila; Ashburn, Ann; Baxter, David

    The purpose of this study was to characterize the gait cycle of patients with hemiplegia before and after a period of outpatient physiotherapy based on the Bobath concept. Nine patients, at least 6 weeks post stroke and recently discharged from a stroke unit, were measured before and after a period of outpatient physiotherapy (mean duration = 17.4 weeks). Therapy was documented using a treatment checklist for each patient. The primary outcome measures were a number of gait variables related to the therapists' treatment hypothesis, recorded during the gait cycle using the CODA motion analysis system. Other secondary outcome measures were the Motor Assessment Scale, Modified Ashworth Scale, subtests of the Sodring Motor Evaluation Scale, the Step test, a 10-m walk test, the Barthel Index and the London Handicap Score. Recovery of more normal gait patterns in the gait cycle (using motion analysis) did not occur. Significant changes in temporal parameters (loading response, single support time) for both legs, in one kinematic (dorsiflexion during stance) and one kinetic variable on the unaffected side (hip flexor moment), and most of the clinical measures of impairment, activity and participation (with the exception of the Modified Ashworth Scale and the 10-m walk) were noted. Study findings did not support the hypothesis that the Bobath approach restored more normal movement patterns to the gait cycle. Further research is required to investigate the treatment techniques that are effective at improving walking ability in people after stroke.

  14. Effects of intensive therapy using gait trainer or floor walking exercises early after stroke.

    PubMed

    Peurala, Sinikka H; Airaksinen, Olavi; Huuskonen, Pirjo; Jäkälä, Pekka; Juhakoski, Mika; Sandell, Kaisa; Tarkka, Ina M; Sivenius, Juhani

    2009-02-01

    To analyse the effects of gait therapy for patients after acute stroke in a randomized controlled trial. Fifty-six patients with a mean of 8 days post-stroke participated in: (i) gait trainer exercise; (ii) walking training over ground; or (iii) conventional treatment. Patients in the gait trainer exercise and walking groups practiced gait for 15 sessions over 3 weeks and received additional physiotherapy. Functional Ambulatory Category and several secondary outcome measures assessing gait and mobility were administered before and after rehabilitation and at 6-month follow-up. Patients also evaluated their own effort. Walking ability improved more with intensive walk training compared with conventional treatment; median Functional Ambulatory Category was zero in all patients at the start of the study, but it was 3 in both walk-training groups and 0.5 in the conventional treatment group at the end of the therapy. Median Functional Ambulatory Category was 4 in both walk-training groups and 2.5 in conventional treatment group at 6-month follow-up. Mean accomplished walking distance was not different between the gait trainer exercise and over ground walking groups. Borg scale indicated more effort in over ground walking. Secondary outcomes also indicated improvements. Exercise therapy with walking training improved gait function irrespective of the method used, but the time and effort required to achieve the results favour the gait trainer exercise. Early intensive gait training resulted in better walking ability than did conventional treatment.

  15. Cognitive Contributions to Gait and Falls: Evidence and Implications

    PubMed Central

    Amboni, Marianna; Barone, Paolo; Hausdorff, Jeffrey M.

    2014-01-01

    Dementia and gait impairments often coexist in older adults and patients with neurodegenerative disease. Both conditions represent independent risk factors for falls. The relationship between cognitive function and gait has recently received increasing attention. Gait is no longer considered merely automated motor activity but rather an activity that requires executive function and attention as well as judgment of external and internal cues. In this review, we intend to: (1) summarize and synthesize the experimental, neuropsychological, and neuroimaging evidence that supports the role played by cognition in the control of gait; and (2) briefly discuss the implications deriving from the interplay between cognition and gait. In recent years, the dual task paradigm has been widely used as an experimental method to explore the interplay between gait and cognition. Several neuropsychological investigations have also demonstrated that walking relies on the use of several cognitive domains, including executive-attentional function, visuospatial abilities, and even memory resources. A number of morphological and functional neuroimaging studies have offered additional evidence supporting the relationship between gait and cognitive resources. Based on the findings from 3 lines of studies, it appears that a growing body of evidence indicates a pivotal role of cognition in gait control and fall prevention. The interplay between higher-order neural function and gait has a number of clinical implications, ranging from integrated assessment tools to possible innovative lines of interventions, including cognitive therapy for falls prevention on one hand and walking program for reducing dementia risk on the other. PMID:24132840

  16. RISK FACTORS FOR SLOW GAIT SPEED: A NESTED CASE-CONTROL SECONDARY ANALYSIS OF THE MEXICAN HEALTH AND AGING STUDY

    PubMed Central

    Pérez-Zepeda, M.U.; González-Chavero, J.G.; Salinas-Martinez, R.; Gutiérrez-Robledo, L.M.

    2016-01-01

    Background Physical performance tests play a major role in the geriatric assessment. In particular, gait speed has shown to be useful for predicting adverse outcomes. However, risk factors for slow gait speed (slowness) are not clearly described. Objectives To determine risk factors associated with slowness in Mexican older adults. Design A two-step process was adopted for exploring the antecedent risk factors of slow gait speed. First, the cut-off values for gait speed were determined in a representative sample of Mexican older adults. Then, antecedent risk factors of slow gait speed (defined using the identified cut-points) were explored in a nested, cohort case-control study. Setting, participants One representative sample of a cross-sectional survey for the first step and the Mexican Health and Aging Study (a cohort characterized by a 10-year follow-up). Measurements A 4-meter usual gait speed test was conducted. Lowest gender and height-stratified groups were considered as defining slow gait speed. Sociodemographic characteristics, comorbidities, psychological and health-care related variables were explored to find those associated with the subsequent development of slow gait speed. Unadjusted and adjusted logistic regression models were performed. Results In the final model, age, diabetes, hypertension, and history of fractures were associated with the development of slow gait speed. Conclusions Early identification of subjects at risk of developing slow gait speed may halt the path to disability due to the robust association of this physical performance test with functional decline. PMID:26889463

  17. Characterization of gait function in patients with postsurgical sagittal (flatback) deformity: a prospective study of 21 patients.

    PubMed

    Sarwahi, Vishal; Boachie-Adjei, Oheneba; Backus, Sherry I; Taira, Gaku

    2002-11-01

    This study prospectively analyzed gait in 21 patients with flatback and reviewed radiographs and charts. To analyze the effect of sagittal imbalance on gait and hip and knee joints. Loss of lumbar lordosis causes anterior displacement of the center of gravity, which creates instability and increases the work of gait. Several compensatory changes occur in response. The long-term effect of these changes on extra-axial joints has not been reported, nor have many studies analyzed the gait deviations in patients with flatback. Over time, as patients' ability to compensate is limited, increased gait deviations result. A total of 21 of 44 patients who had gait analysis as part of the preoperative workup were selected based on outlined criteria. Kinetics and kinematics data were analyzed along with radiographic and chart review. Normal healthy individuals served as controls. Gait deviations were present in gait kinetics and kinematics, including decreased stride length and velocity, to almost 60% of controls. Stance duration was prolonged with increased hip and knee flexion during stance. Hip and knee extensor moments were decreased with vertical ground reaction force showing slower rate of loading, reduced peak values, and flattening of normal loading response. Patients with flatback develop several compensatory mechanisms. The goal of the compensation is to maintain an efficient gait and decrease joint damage, but these safeguards fail over time. Flatback not only causes backache, abnormal posture, and abnormal body mechanics but also compromises the stability of gait and taxes the knee and hip joints adversely.

  18. Improving Sensitivity to Detect Mild Cognitive Impairment: Cognitive Load Dual-Task Gait Speed Assessment.

    PubMed

    MacAulay, Rebecca K; Wagner, Mark T; Szeles, Dana; Milano, Nicholas J

    2017-07-01

    Longitudinal research indicates that cognitive load dual-task gait assessment is predictive of cognitive decline and thus might provide a sensitive measure to screen for mild cognitive impairment (MCI). However, research among older adults being clinically evaluated for cognitive concerns, a defining feature of MCI, is lacking. The present study investigated the effect of performing a cognitive task on normal walking speed in patients presenting to a memory clinic with cognitive complaints. Sixty-one patients with a mean age of 68 years underwent comprehensive neuropsychological testing, clinical interview, and gait speed (simple- and dual-task conditions) assessments. Thirty-four of the 61 patients met criteria for MCI. Repeated measure analyses of covariance revealed that greater age and MCI both significantly associated with slower gait speed, ps<.05. Follow-up analysis indicated that the MCI group had significantly slower dual-task gait speed but did not differ in simple-gait speed. Multivariate linear regression across groups found that executive attention performance accounted for 27.4% of the variance in dual-task gait speed beyond relevant demographic and health risk factors. The present study increases the external validity of dual-task gait assessment of MCI. Differences in dual-task gait speed appears to be largely attributable to executive attention processes. These findings have clinical implications as they demonstrate expected patterns of gait-brain behavior relationships in response to a cognitive dual task within a clinically representative population. Cognitive load dual-task gait assessment may provide a cost efficient and sensitive measure to detect older adults at high risk of a dementia disorder. (JINS, 2017, 23, 493-501).

  19. Gait and Functional Mobility Deficits in Fragile X-Associated Tremor/Ataxia Syndrome.

    PubMed

    O'Keefe, Joan A; Robertson-Dick, Erin E; Hall, Deborah A; Berry-Kravis, Elizabeth

    2016-08-01

    Fragile X-associated tremor/ataxia syndrome (FXTAS) results from a "premutation" (PM) size CGG repeat expansion in the fragile X mental retardation 1 (FMR1) gene. Cerebellar gait ataxia is the primary feature in some FXTAS patients causing progressive disability. However, no studies have quantitatively characterized gait and mobility deficits in FXTAS. We performed quantitative gait and mobility analysis in seven FMR1 PM carriers with FXTAS and ataxia, six PM carriers without FXTAS, and 18 age-matched controls. We studied four independent gait domains, trunk range of motion (ROM), and movement transitions using an instrumented Timed Up and Go (i-TUG). We correlated these outcome measures with FMR1 molecular variables and clinical severity scales. PM carriers with FXTAS were globally impaired in every gait performance domain except trunk ROM compared to controls. These included total i-TUG duration, stride velocity, gait cycle time, cadence, double-limb support and swing phase times, turn duration, step time before turn, and turn-to-sit duration, and increased gait variability on several measures. Carriers without FXTAS did not differ from controls on any parameters, but double-limb support time was close to significance. Balance and disability scales correlated with multiple gait and movement transition parameters, while the FXTAS Rating Scale did not. This is the first study to quantitatively examine gait and movement transitions in FXTAS patients. Gait characteristics were consistent with those from previous cohorts with cerebellar ataxia. Sensitive measures like the i-TUG may help determine efficacy of interventions, characterize disease progression, and provide early markers of disease in FXTAS.

  20. Quadrupedal gaits in hexapod animals - inter-leg coordination in free-walking adult stick insects.

    PubMed

    Grabowska, Martyna; Godlewska, Elzbieta; Schmidt, Joachim; Daun-Gruhn, Silvia

    2012-12-15

    The analysis of inter-leg coordination in insect walking is generally a study of six-legged locomotion. For decades, the stick insect Carausius morosus has been instrumental for unravelling the rules and mechanisms that control leg coordination in hexapeds. We analysed inter-leg coordination in C. morosus that freely walked on straight paths on plane surfaces with different slopes. Consecutive 1.7 s sections were assigned inter-leg coordination patterns (which we call gaits) based on footfall patterns. Regular gaits, i.e. wave, tetrapod or tripod gaits, occurred in different proportions depending on surface slopes. Tetrapod gaits were observed most frequently, wave gaits only occurred on 90 deg inclining slopes and tripod gaits occurred most often on 15 deg declining slopes, i.e. in 40% of the sections. Depending on the slope, 36-66% of the sections were assigned irregular gaits. Irregular gaits were mostly due to multiple stepping by the front legs, which is perhaps probing behaviour, not phase coupled to the middle legs' cycles. In irregular gaits, middle leg and hindleg coordination was regular, related to quadrupedal walk and wave gaits. Apparently, front legs uncouple from and couple to the walking system without compromising middle leg and hindleg coordination. In front leg amputees, the remaining legs were strictly coordinated. In hindleg and middle leg amputees, the front legs continued multiple stepping. The coordination of middle leg amputees was maladapted, with front legs and hindlegs performing multiple steps or ipsilateral legs being in simultaneous swing. Thus, afferent information from middle legs might be necessary for a regular hindleg stepping pattern.

Top