Sample records for gait cycle parameters

  1. Real-Time Gait Cycle Parameter Recognition Using a Wearable Accelerometry System

    PubMed Central

    Yang, Che-Chang; Hsu, Yeh-Liang; Shih, Kao-Shang; Lu, Jun-Ming

    2011-01-01

    This paper presents the development of a wearable accelerometry system for real-time gait cycle parameter recognition. Using a tri-axial accelerometer, the wearable motion detector is a single waist-mounted device to measure trunk accelerations during walking. Several gait cycle parameters, including cadence, step regularity, stride regularity and step symmetry can be estimated in real-time by using autocorrelation procedure. For validation purposes, five Parkinson’s disease (PD) patients and five young healthy adults were recruited in an experiment. The gait cycle parameters among the two subject groups of different mobility can be quantified and distinguished by the system. Practical considerations and limitations for implementing the autocorrelation procedure in such a real-time system are also discussed. This study can be extended to the future attempts in real-time detection of disabling gaits, such as festinating or freezing of gait in PD patients. Ambulatory rehabilitation, gait assessment and personal telecare for people with gait disorders are also possible applications. PMID:22164019

  2. Energy Expenditure of Trotting Gait Under Different Gait Parameters

    NASA Astrophysics Data System (ADS)

    Chen, Xian-Bao; Gao, Feng

    2017-07-01

    Robots driven by batteries are clean, quiet, and can work indoors or in space. However, the battery endurance is a great problem. A new gait parameter design energy saving strategy to extend the working hours of the quadruped robot is proposed. A dynamic model of the robot is established to estimate and analyze the energy expenditures during trotting. Given a trotting speed, optimal stride frequency and stride length can minimize the energy expenditure. However, the relationship between the speed and the optimal gait parameters is nonlinear, which is difficult for practical application. Therefore, a simplified gait parameter design method for energy saving is proposed. A critical trotting speed of the quadruped robot is found and can be used to decide the gait parameters. When the robot is travelling lower than this speed, it is better to keep a constant stride length and change the cycle period. When the robot is travelling higher than this speed, it is better to keep a constant cycle period and change the stride length. Simulations and experiments on the quadruped robot show that by using the proposed gait parameter design approach, the energy expenditure can be reduced by about 54% compared with the 100 mm stride length under 500 mm/s speed. In general, an energy expenditure model based on the gait parameter of the quadruped robot is built and the trotting gait parameters design approach for energy saving is proposed.

  3. Relationships of stroke patients' gait parameters with fear of falling.

    PubMed

    Park, Jin; Yoo, Ingyu

    2014-12-01

    [Purpose] The purpose of this study was to assess the correlation of gait parameters with fear of falling in stroke survivors. [Subjects] In total, 12 patients with stroke participated. [Methods] The subjects performed on a Biodex Gait Trainer 2 for 5 min to evaluate characteristic gait parameters. The kinematic gait parameters measured were gait speed, step cycle, step length, and time on each foot (step symmetry). All the subjects also completed a fall anxiety survey. [Results] Correlations between gait parameters and fear of falling scores were calculated. There was a moderate degree of correlation between fear of falling scores and the step cycle item of gait parameters. [Conclusions] According to our results, the step cycle gait parameter may be related to increased fall anxiety.

  4. Gait parameter control timing with dynamic manual contact or visual cues.

    PubMed

    Rabin, Ely; Shi, Peter; Werner, William

    2016-06-01

    We investigated the timing of gait parameter changes (stride length, peak toe velocity, and double-, single-support, and complete step duration) to control gait speed. Eleven healthy participants adjusted their gait speed on a treadmill to maintain a constant distance between them and a fore-aft oscillating cue (a place on a conveyor belt surface). The experimental design balanced conditions of cue modality (vision: eyes-open; manual contact: eyes-closed while touching the cue); treadmill speed (0.2, 0.4, 0.85, and 1.3 m/s); and cue motion (none, ±10 cm at 0.09, 0.11, and 0.18 Hz). Correlation analyses revealed a number of temporal relationships between gait parameters and cue speed. The results suggest that neural control ranged from feedforward to feedback. Specifically, step length preceded cue velocity during double-support duration suggesting anticipatory control. Peak toe velocity nearly coincided with its most-correlated cue velocity during single-support duration. The toe-off concluding step and double-support durations followed their most-correlated cue velocity, suggesting feedback control. Cue-tracking accuracy and cue velocity correlations with timing parameters were higher with the manual contact cue than visual cue. The cue/gait timing relationships generalized across cue modalities, albeit with greater delays of step-cycle events relative to manual contact cue velocity. We conclude that individual kinematic parameters of gait are controlled to achieve a desired velocity at different specific times during the gait cycle. The overall timing pattern of instantaneous cue velocities associated with different gait parameters is conserved across cues that afford different performance accuracies. This timing pattern may be temporally shifted to optimize control. Different cue/gait parameter latencies in our nonadaptation paradigm provide general-case evidence of the independent control of gait parameters previously demonstrated in gait adaptation paradigms

  5. Gait parameter control timing with dynamic manual contact or visual cues

    PubMed Central

    Shi, Peter; Werner, William

    2016-01-01

    We investigated the timing of gait parameter changes (stride length, peak toe velocity, and double-, single-support, and complete step duration) to control gait speed. Eleven healthy participants adjusted their gait speed on a treadmill to maintain a constant distance between them and a fore-aft oscillating cue (a place on a conveyor belt surface). The experimental design balanced conditions of cue modality (vision: eyes-open; manual contact: eyes-closed while touching the cue); treadmill speed (0.2, 0.4, 0.85, and 1.3 m/s); and cue motion (none, ±10 cm at 0.09, 0.11, and 0.18 Hz). Correlation analyses revealed a number of temporal relationships between gait parameters and cue speed. The results suggest that neural control ranged from feedforward to feedback. Specifically, step length preceded cue velocity during double-support duration suggesting anticipatory control. Peak toe velocity nearly coincided with its most-correlated cue velocity during single-support duration. The toe-off concluding step and double-support durations followed their most-correlated cue velocity, suggesting feedback control. Cue-tracking accuracy and cue velocity correlations with timing parameters were higher with the manual contact cue than visual cue. The cue/gait timing relationships generalized across cue modalities, albeit with greater delays of step-cycle events relative to manual contact cue velocity. We conclude that individual kinematic parameters of gait are controlled to achieve a desired velocity at different specific times during the gait cycle. The overall timing pattern of instantaneous cue velocities associated with different gait parameters is conserved across cues that afford different performance accuracies. This timing pattern may be temporally shifted to optimize control. Different cue/gait parameter latencies in our nonadaptation paradigm provide general-case evidence of the independent control of gait parameters previously demonstrated in gait adaptation paradigms

  6. Impact of SCBA size and fatigue from different firefighting work cycles on firefighter gait.

    PubMed

    Kesler, Richard M; Bradley, Faith F; Deetjen, Grace S; Angelini, Michael J; Petrucci, Matthew N; Rosengren, Karl S; Horn, Gavin P; Hsiao-Wecksler, Elizabeth T

    2018-04-04

    Risk of slips, trips and falls in firefighters maybe influenced by the firefighter's equipment and duration of firefighting. This study examined the impact of a four self-contained breathing apparatus (SCBA) three SCBA of increasing size and a prototype design and three work cycles one bout (1B), two bouts with a five-minute break (2B) and two bouts back-to-back (BB) on gait in 30 firefighters. Five gait parameters (double support time, single support time, stride length, step width and stride velocity) were examined pre- and post-firefighting activity. The two largest SCBA resulted in longer double support times relative to the smallest SCBA. Multiple bouts of firefighting activity resulted in increased single and double support time and decreased stride length, step width and stride velocity. These results suggest that with larger SCBA or longer durations of activity, firefighters may adopt more conservative gait patterns to minimise fall risk. Practitioner Summary: The effects of four self-contained breathing apparatus (SCBA) and three work cycles on five gait parameters were examined pre- and post-firefighting activity. Both SCBA size and work cycle affected gait. The two largest SCBA resulted in longer double support times. Multiple bouts of activity resulted in more conservative gait patterns.

  7. Effects of 12-week supervised treadmill training on spatio-temporal gait parameters in patients with claudication.

    PubMed

    Konik, Anita; Kuklewicz, Stanisław; Rosłoniec, Ewelina; Zając, Marcin; Spannbauer, Anna; Nowobilski, Roman; Mika, Piotr

    2016-01-01

    The purpose of the study was to evaluate selected temporal and spatial gait parameters in patients with intermittent claudication after completion of 12-week supervised treadmill walking training. The study included 36 patients (26 males and 10 females) aged: mean 64 (SD 7.7) with intermittent claudication. All patients were tested on treadmill (Gait Trainer, Biodex). Before the programme and after its completion, the following gait biomechanical parameters were tested: step length (cm), step cycle (cycle/s), leg support time (%), coefficient of step variation (%) as well as pain-free walking time (PFWT) and maximal walking time (MWT) were measured. Training was conducted in accordance with the current TASC II guidelines. After 12 weeks of training, patients showed significant change in gait biomechanics consisting in decreased frequency of step cycle (p < 0.05) and extended step length (p < 0.05). PFWT increased by 96% (p < 0.05). MWT increased by 100% (p < 0.05). After completing the training, patients' gait was more regular, which was expressed via statistically significant decrease of coefficient of variation (p < 0.05) for both legs. No statistically significant relation between the post-training improvement of PFWT and MWT and step length increase and decreased frequency of step cycle was observed (p > 0.05). Twelve-week treadmill walking training programme may lead to significant improvement of temporal and spatial gait parameters in patients with intermittent claudication. Twelve-week treadmill walking training programme may lead to significant improvement of pain-free walking time and maximum walking time in patients with intermittent claudication.

  8. The effect of uphill and downhill walking on gait parameters: A self-paced treadmill study.

    PubMed

    Kimel-Naor, Shani; Gottlieb, Amihai; Plotnik, Meir

    2017-07-26

    It has been shown that gait parameters vary systematically with the slope of the surface when walking uphill (UH) or downhill (DH) (Andriacchi et al., 1977; Crowe et al., 1996; Kawamura et al., 1991; Kirtley et al., 1985; McIntosh et al., 2006; Sun et al., 1996). However, gait trials performed on inclined surfaces have been subject to certain technical limitations including using fixed speed treadmills (TMs) or, alternatively, sampling only a few gait cycles on inclined ramps. Further, prior work has not analyzed upper body kinematics. This study aims to investigate effects of slope on gait parameters using a self-paced TM (SPTM) which facilitates more natural walking, including measuring upper body kinematics and gait coordination parameters. Gait of 11 young healthy participants was sampled during walking in steady state speed. Measurements were made at slopes of +10°, 0° and -10°. Force plates and a motion capture system were used to reconstruct twenty spatiotemporal gait parameters. For validation, previously described parameters were compared with the literature, and novel parameters measuring upper body kinematics and bilateral gait coordination were also analyzed. Results showed that most lower and upper body gait parameters were affected by walking slope angle. Specifically, UH walking had a higher impact on gait kinematics than DH walking. However, gait coordination parameters were not affected by walking slope, suggesting that gait asymmetry, left-right coordination and gait variability are robust characteristics of walking. The findings of the study are discussed in reference to a potential combined effect of slope and gait speed. Follow-up studies are needed to explore the relative effects of each of these factors. Copyright © 2017. Published by Elsevier Ltd.

  9. Gait variability and basal ganglia disorders: stride-to-stride variations of gait cycle timing in Parkinson's disease and Huntington's disease

    NASA Technical Reports Server (NTRS)

    Hausdorff, J. M.; Cudkowicz, M. E.; Firtion, R.; Wei, J. Y.; Goldberger, A. L.

    1998-01-01

    The basal ganglia are thought to play an important role in regulating motor programs involved in gait and in the fluidity and sequencing of movement. We postulated that the ability to maintain a steady gait, with low stride-to-stride variability of gait cycle timing and its subphases, would be diminished with both Parkinson's disease (PD) and Huntington's disease (HD). To test this hypothesis, we obtained quantitative measures of stride-to-stride variability of gait cycle timing in subjects with PD (n = 15), HD (n = 20), and disease-free controls (n = 16). All measures of gait variability were significantly increased in PD and HD. In subjects with PD and HD, gait variability measures were two and three times that observed in control subjects, respectively. The degree of gait variability correlated with disease severity. In contrast, gait speed was significantly lower in PD, but not in HD, and average gait cycle duration and the time spent in many subphases of the gait cycle were similar in control subjects, HD subjects, and PD subjects. These findings are consistent with a differential control of gait variability, speed, and average gait cycle timing that may have implications for understanding the role of the basal ganglia in locomotor control and for quantitatively assessing gait in clinical settings.

  10. Automated extraction and validation of children's gait parameters with the Kinect.

    PubMed

    Motiian, Saeid; Pergami, Paola; Guffey, Keegan; Mancinelli, Corrie A; Doretto, Gianfranco

    2015-12-02

    Gait analysis for therapy regimen prescription and monitoring requires patients to physically access clinics with specialized equipment. The timely availability of such infrastructure at the right frequency is especially important for small children. Besides being very costly, this is a challenge for many children living in rural areas. This is why this work develops a low-cost, portable, and automated approach for in-home gait analysis, based on the Microsoft Kinect. A robust and efficient method for extracting gait parameters is introduced, which copes with the high variability of noisy Kinect skeleton tracking data experienced across the population of young children. This is achieved by temporally segmenting the data with an approach based on coupling a probabilistic matching of stride template models, learned offline, with the estimation of their global and local temporal scaling. A preliminary study conducted on healthy children between 2 and 4 years of age is performed to analyze the accuracy, precision, repeatability, and concurrent validity of the proposed method against the GAITRite when measuring several spatial and temporal children's gait parameters. The method has excellent accuracy and good precision, with segmenting temporal sequences of body joint locations into stride and step cycles. Also, the spatial and temporal gait parameters, estimated automatically, exhibit good concurrent validity with those provided by the GAITRite, as well as very good repeatability. In particular, on a range of nine gait parameters, the relative and absolute agreements were found to be good and excellent, and the overall agreements were found to be good and moderate. This work enables and validates the automated use of the Kinect for children's gait analysis in healthy subjects. In particular, the approach makes a step forward towards developing a low-cost, portable, parent-operated in-home tool for clinicians assisting young children.

  11. Validity and repeatability of inertial measurement units for measuring gait parameters.

    PubMed

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Concurrent validity and reliability of wireless instrumented insoles measuring postural balance and temporal gait parameters.

    PubMed

    Oerbekke, Michiel S; Stukstette, Mirelle J; Schütte, Kurt; de Bie, Rob A; Pisters, Martijn F; Vanwanseele, Benedicte

    2017-01-01

    The OpenGo seems promising to take gait analysis out of laboratory settings due to its capability of long-term measurements and mobility. However, the OpenGo's concurrent validity and reliability need to be assessed to determine if the instrument is suitable for validation in patient samples. Twenty healthy volunteers participated. Center of pressure data were collected under eyes open and closed conditions with participants performing unilateral stance trials on the gold standard (AMTI OR6-7 force plate) while wearing the OpenGo. Temporal gait data (stance time, gait cycle time, and cadence) were collected at a self-selected comfortable walking speed with participants performing test-retest trials on an instrumented treadmill while wearing the OpenGo. Validity was assessed using Bland-Altman plots. Reliability was assessed with Intraclass Correlation Coefficient (2,1) and smallest detectable changes were calculated. Negative means of differences were found in all measured parameters, illustrating lower scores for the OpenGo on average. The OpenGo showed negative upper limits of agreement in center of pressure parameters on the mediolateral axis. Temporal reliability ICCs ranged from 0.90-0.93. Smallest detectable changes for both stance times were 0.04 (left) and 0.05 (right) seconds, for gait cycle time 0.08s, and for cadence 4.5 steps per minute. The OpenGo is valid and reliable for the measurement of temporal gait parameters during walking. Measurements of center of pressure parameters during unilateral stance are not considered valid. The OpenGo seems a promising instrument for clinically screening and monitoring temporal gait parameters in patients, however validation in patient populations is needed. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Non-MTC gait cycles: An adaptive toe trajectory control strategy in older adults.

    PubMed

    Santhiranayagam, Braveena K; Sparrow, W A; Lai, Daniel T H; Begg, Rezaul K

    2017-03-01

    Minimum-toe-clearance (MTC) above the walking surface is a critical representation of toe-trajectory control due to its association with tripping risk. Not all gait cycles exhibit a clearly defined MTC within the swing phase but there have been few previous accounts of the biomechanical characteristics of non-MTC gait cycles. The present report investigated the within-subject non-MTC gait cycle characteristics of 15 older adults (mean 73.1 years) and 15 young controls (mean 26.1 years). Participants performed the following tasks on a motorized treadmill: preferred speed walking, dual task walking (carrying a glass of water) and a dual-task speed-matched control. Toe position-time coordinates were acquired using a 3 dimensional motion capture system. When MTC was present, toe height at MTC (MTC height ) was extracted. The proportion of non-MTC gait cycles was computed for the age groups and individuals. For non-MTC gait cycles an 'indicative' toe height at the individual's average swing phase time (MTC time ) for observed MTC cycles was averaged across multiple non-MTC gait cycles. In preferred-speed walking Young demonstrated 2.9% non-MTC gait cycles and Older 18.7%. In constrained walking conditions both groups increased non-MTC gait cycles and some older adults revealed over 90%, confirming non-MTC gait cycles as an ageing-related phenomenon in lower limb trajectory control. For all participants median indicative toe-height on non-MTC gait cycles was greater than median MTC height . This result suggests that eliminating the biomechanically hazardous MTC event by adopting more of the higher-clearance non-MTC gait cycles, is adaptive in reducing the likelihood of toe-ground contact. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Effect of visual biofeedback cycling training on gait in patients with multiple sclerosis.

    PubMed

    Hochsprung, A; Granja Domínguez, A; Magni, E; Escudero Uribe, S; Moreno García, A

    2017-09-06

    Gait alterations are present in a high percentage of patients with multiple sclerosis (MS). They appear from early stages of the disease and can limit patients' capacity to perform basic activities of daily living, affecting their quality of life. Visual biofeedback cycling training appears to be a useful tool in treating these impairments. This study aims to evaluate the short-term effect of visual biofeedback cycling training on gait in patients with MS. A total of 61 patients with mild to moderate MS were randomly assigned to a control group and an intervention group. The intervention group received visual biofeedback cycling training (MOTOmed viva2 system) once per week for 3 months, and a home exercise program. The control group only received the home exercise program. Both groups were evaluated using the GAITRite ® Walkway gait assessment system before the intervention, during the first month of the programme, and after the intervention. In the intervention group, the analysis revealed statistically significant differences between Functional Ambulation Profile (FAP) scores before and during the intervention (P=.014), and before and after the intervention (P=.002). A statistically significant improvement was observed in step length in the intervention group between pre- and post-intervention scores (P=.001) and between first-month and post-intervention scores (P=.004). Visual biofeedback cycling training improved specific gait parameters in the short term and appears to be a therapeutic option for gait retraining in patients with MS. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. A possible parameter for gait clinimetric evaluation in Parkinson’s disease patients

    NASA Astrophysics Data System (ADS)

    Lescano, C. N.; Rodrigo, S. E.; Christian, D. A.

    2016-04-01

    The strength and usefulness of a rating scale for describing disease evolution relies on the accurate determination of variations representing clinically relevant changes. In this sense, the habitually used Hoehn-Yahr (HY) Scale for Parkinson Disease (PD) in its modified version distinguishes between the 2 and 2.5 stages to explain if the bilateral involvement is or is not accompanied by body balance impairment. Nevertheless, this scaling does not allow for differentiating the symptoms and signs associated with each stage accurately. Considering this difference, this work aims at analyzing some gait parameters-stance and swing phase times and magnitude of the vertical component of ground reaction force during the gait cycle-of PD patients classified as HY=2 and HY=2.5 in contrast with healthy subjects (HY=0), with the purpose of assessing whether there is a statistically significant difference among all these HY categories. For all gait parameters evaluated, the results indicated significant differences between HY=0 and HY=2.5. However, only the magnitude of the vertical component of ground reaction force presented relevant differences between HY=2 and 2.5. As expected, therefore, these results show the potential of such parameter to clinimetrically identify the level of gait impairment/disability in PD patients on the Hoehn-Yahr Scale.

  16. Spatial parameters of walking gait and footedness.

    PubMed

    Zverev, Y P

    2006-01-01

    The present study was undertaken to assess whether footedness has effects on selected spatial and angular parameters of able-bodied gait by evaluating footprints of young adults. A total of 112 males and 93 females were selected from among students and staff members of the University of Malawi using a simple random sampling method. Footedness of subjects was assessed by the Waterloo Footedness Questionnaire Revised. Gait at natural speed was recorded using the footprint method. The following spatial parameters of gait were derived from the inked footprint sequences of subjects: step and stride lengths, gait angle and base of gait. The anthropometric measurements taken were weight, height, leg and foot length, foot breadth, shoulder width, and hip and waist circumferences. The prevalence of right-, left- and mix-footedness in the whole sample of young Malawian adults was 81%, 8.3% and 10.7%, respectively. One-way analysis of variance did not reveal a statistically significant difference between footedness categories in the mean values of anthropometric measurements (p > 0.05 for all variables). Gender differences in step and stride length values were not statistically significant. Correction of these variables for stature did not change the trend. Males had significantly broader steps than females. Normalized values of base of gait had similar gender difference. The group means of step length and normalized step length of the right and left feet were similar, for males and females. There was a significant side difference in the gait angle in both gender groups of volunteers with higher mean values on the left side compared to the right one (t = 2.64, p < 0.05 for males, and t = 2.78, p < 0.05 for females). One-way analysis of variance did not demonstrate significant difference between footedness categories in the mean values of step length, gait angle, bilateral differences in step length and gait angle, stride length, gait base and normalized gait variables of male

  17. Wearable sensors objectively measure gait parameters in Parkinson’s disease

    PubMed Central

    Marxreiter, Franz; Gossler, Julia; Kohl, Zacharias; Reinfelder, Samuel; Gassner, Heiko; Aminian, Kamiar; Eskofier, Bjoern M.; Winkler, Jürgen; Klucken, Jochen

    2017-01-01

    Distinct gait characteristics like short steps and shuffling gait are prototypical signs commonly observed in Parkinson’s disease. Routinely assessed by observation through clinicians, gait is rated as part of categorical clinical scores. There is an increasing need to provide quantitative measurements of gait, e.g. to provide detailed information about disease progression. Recently, we developed a wearable sensor-based gait analysis system as diagnostic tool that objectively assesses gait parameter in Parkinson’s disease without the need of having a specialized gait laboratory. This system consists of inertial sensor units attached laterally to both shoes. The computed target of measures are spatiotemporal gait parameters including stride length and time, stance phase time, heel-strike and toe-off angle, toe clearance, and inter-stride variation from gait sequences. To translate this prototype into medical care, we conducted a cross-sectional study including 190 Parkinson’s disease patients and 101 age-matched controls and measured gait characteristics during a 4x10 meter walk at the subjects’ preferred speed. To determine intraindividual changes in gait, we monitored the gait characteristics of 63 patients longitudinally. Cross-sectional analysis revealed distinct spatiotemporal gait parameter differences reflecting typical Parkinson’s disease gait characteristics including short steps, shuffling gait, and postural instability specific for different disease stages and levels of motor impairment. The longitudinal analysis revealed that gait parameters were sensitive to changes by mirroring the progressive nature of Parkinson’s disease and corresponded to physician ratings. Taken together, we successfully show that wearable sensor-based gait analysis reaches clinical applicability providing a high biomechanical resolution for gait impairment in Parkinson’s disease. These data demonstrate the feasibility and applicability of objective wearable sensor

  18. Extraction of human gait signatures: an inverse kinematic approach using Groebner basis theory applied to gait cycle analysis

    NASA Astrophysics Data System (ADS)

    Barki, Anum; Kendricks, Kimberly; Tuttle, Ronald F.; Bunker, David J.; Borel, Christoph C.

    2013-05-01

    This research highlights the results obtained from applying the method of inverse kinematics, using Groebner basis theory, to the human gait cycle to extract and identify lower extremity gait signatures. The increased threat from suicide bombers and the force protection issues of today have motivated a team at Air Force Institute of Technology (AFIT) to research pattern recognition in the human gait cycle. The purpose of this research is to identify gait signatures of human subjects and distinguish between subjects carrying a load to those subjects without a load. These signatures were investigated via a model of the lower extremities based on motion capture observations, in particular, foot placement and the joint angles for subjects affected by carrying extra load on the body. The human gait cycle was captured and analyzed using a developed toolkit consisting of an inverse kinematic motion model of the lower extremity and a graphical user interface. Hip, knee, and ankle angles were analyzed to identify gait angle variance and range of motion. Female subjects exhibited the most knee angle variance and produced a proportional correlation between knee flexion and load carriage.

  19. Quantifying dynamic characteristics of human walking for comprehensive gait cycle.

    PubMed

    Mummolo, Carlotta; Mangialardi, Luigi; Kim, Joo H

    2013-09-01

    Normal human walking typically consists of phases during which the body is statically unbalanced while maintaining dynamic stability. Quantifying the dynamic characteristics of human walking can provide better understanding of gait principles. We introduce a novel quantitative index, the dynamic gait measure (DGM), for comprehensive gait cycle. The DGM quantifies the effects of inertia and the static balance instability in terms of zero-moment point and ground projection of center of mass and incorporates the time-varying foot support region (FSR) and the threshold between static and dynamic walking. Also, a framework of determining the DGM from experimental data is introduced, in which the gait cycle segmentation is further refined. A multisegmental foot model is integrated into a biped system to reconstruct the walking motion from experiments, which demonstrates the time-varying FSR for different subphases. The proof-of-concept results of the DGM from a gait experiment are demonstrated. The DGM results are analyzed along with other established features and indices of normal human walking. The DGM provides a measure of static balance instability of biped walking during each (sub)phase as well as the entire gait cycle. The DGM of normal human walking has the potential to provide some scientific insights in understanding biped walking principles, which can also be useful for their engineering and clinical applications.

  20. Estimation of Temporal Gait Parameters Using a Wearable Microphone-Sensor-Based System

    PubMed Central

    Wang, Cheng; Wang, Xiangdong; Long, Zhou; Yuan, Jing; Qian, Yueliang; Li, Jintao

    2016-01-01

    Most existing wearable gait analysis methods focus on the analysis of data obtained from inertial sensors. This paper proposes a novel, low-cost, wireless and wearable gait analysis system which uses microphone sensors to collect footstep sound signals during walking. This is the first time a microphone sensor is used as a wearable gait analysis device as far as we know. Based on this system, a gait analysis algorithm for estimating the temporal parameters of gait is presented. The algorithm fully uses the fusion of two feet footstep sound signals and includes three stages: footstep detection, heel-strike event and toe-on event detection, and calculation of gait temporal parameters. Experimental results show that with a total of 240 data sequences and 1732 steps collected using three different gait data collection strategies from 15 healthy subjects, the proposed system achieves an average 0.955 F1-measure for footstep detection, an average 94.52% accuracy rate for heel-strike detection and 94.25% accuracy rate for toe-on detection. Using these detection results, nine temporal related gait parameters are calculated and these parameters are consistent with their corresponding normal gait temporal parameters and labeled data calculation results. The results verify the effectiveness of our proposed system and algorithm for temporal gait parameter estimation. PMID:27999321

  1. Does Nordic walking improves the postural control and gait parameters of women between the age 65 and 74: a randomized trial

    PubMed Central

    Kocur, Piotr; Wiernicka, Marzena; Wilski, Maciej; Kaminska, Ewa; Furmaniuk, Lech; Maslowska, Marta Flis; Lewandowski, Jacek

    2015-01-01

    [Purpose] To assess the effect of 12-weeks Nordic walking training on gait parameters and some elements of postural control. [Subjects and Methods] Sixty-seven women aged 65 to 74 years were enrolled in this study. The subjects were divided into a Nordic Walking group (12 weeks of Nordic walking training, 3 times a week for 75 minutes) and a control group. In both study groups, a set of functional tests were conducted at the beginning and at the end of the study: the Forward Reach Test (FRT) and the Upward Reach Test (URT) on a stabilometric platform, and the analysis of gait parameters on a treadmill. [Results] The NW group showed improvements in: the range of reach in the FRT test and the URT test in compared to the control group. The length of the gait cycle and gait cycle frequency also showed changes in the NW group compared to the control group. [Conclusion] A 12-week NW training program had a positive impact on selected gait parameters and may improve the postural control of women aged over 65 according to the results selected functional tests. PMID:26834341

  2. Does Nordic walking improves the postural control and gait parameters of women between the age 65 and 74: a randomized trial.

    PubMed

    Kocur, Piotr; Wiernicka, Marzena; Wilski, Maciej; Kaminska, Ewa; Furmaniuk, Lech; Maslowska, Marta Flis; Lewandowski, Jacek

    2015-12-01

    [Purpose] To assess the effect of 12-weeks Nordic walking training on gait parameters and some elements of postural control. [Subjects and Methods] Sixty-seven women aged 65 to 74 years were enrolled in this study. The subjects were divided into a Nordic Walking group (12 weeks of Nordic walking training, 3 times a week for 75 minutes) and a control group. In both study groups, a set of functional tests were conducted at the beginning and at the end of the study: the Forward Reach Test (FRT) and the Upward Reach Test (URT) on a stabilometric platform, and the analysis of gait parameters on a treadmill. [Results] The NW group showed improvements in: the range of reach in the FRT test and the URT test in compared to the control group. The length of the gait cycle and gait cycle frequency also showed changes in the NW group compared to the control group. [Conclusion] A 12-week NW training program had a positive impact on selected gait parameters and may improve the postural control of women aged over 65 according to the results selected functional tests.

  3. Guidelines for Assessment of Gait and Reference Values for Spatiotemporal Gait Parameters in Older Adults: The Biomathics and Canadian Gait Consortiums Initiative

    PubMed Central

    Beauchet, Olivier; Allali, Gilles; Sekhon, Harmehr; Verghese, Joe; Guilain, Sylvie; Steinmetz, Jean-Paul; Kressig, Reto W.; Barden, John M.; Szturm, Tony; Launay, Cyrille P.; Grenier, Sébastien; Bherer, Louis; Liu-Ambrose, Teresa; Chester, Vicky L.; Callisaya, Michele L.; Srikanth, Velandai; Léonard, Guillaume; De Cock, Anne-Marie; Sawa, Ryuichi; Duque, Gustavo; Camicioli, Richard; Helbostad, Jorunn L.

    2017-01-01

    Background: Gait disorders, a highly prevalent condition in older adults, are associated with several adverse health consequences. Gait analysis allows qualitative and quantitative assessments of gait that improves the understanding of mechanisms of gait disorders and the choice of interventions. This manuscript aims (1) to give consensus guidance for clinical and spatiotemporal gait analysis based on the recorded footfalls in older adults aged 65 years and over, and (2) to provide reference values for spatiotemporal gait parameters based on the recorded footfalls in healthy older adults free of cognitive impairment and multi-morbidities. Methods: International experts working in a network of two different consortiums (i.e., Biomathics and Canadian Gait Consortium) participated in this initiative. First, they identified items of standardized information following the usual procedure of formulation of consensus findings. Second, they merged databases including spatiotemporal gait assessments with GAITRite® system and clinical information from the “Gait, cOgnitiOn & Decline” (GOOD) initiative and the Generation 100 (Gen 100) study. Only healthy—free of cognitive impairment and multi-morbidities (i.e., ≤ 3 therapeutics taken daily)—participants aged 65 and older were selected. Age, sex, body mass index, mean values, and coefficients of variation (CoV) of gait parameters were used for the analyses. Results: Standardized systematic assessment of three categories of items, which were demographics and clinical information, and gait characteristics (clinical and spatiotemporal gait analysis based on the recorded footfalls), were selected for the proposed guidelines. Two complementary sets of items were distinguished: a minimal data set and a full data set. In addition, a total of 954 participants (mean age 72.8 ± 4.8 years, 45.8% women) were recruited to establish the reference values. Performance of spatiotemporal gait parameters based on the recorded

  4. Spatial-temporal parameters of gait in women with fibromyalgia.

    PubMed

    Heredia Jiménez, José María; Aparicio García-Molina, Virginia A; Porres Foulquie, Jesús M; Delgado Fernández, Manuel; Soto Hermoso, Victor M

    2009-05-01

    The aim of the present study was to determine if there are differences in such parameters among patients affected by fibromyalgia (FM) and healthy subjects and whether the degree of affectation by FM can decrease the gait parameters. We studied 55 women with FM and 44 controls. Gait analysis was performed using an instrumented walkway for measurement of the kinematic parameters of gait (GAITRite system), and patients completed a Spanish version of Fibromyalgia Impact Questionnaire (FIQ). Significant differences (p < 0.001) between FM and control groups were found in velocity, stride length, cadence, single support ratio, double support ratio, stance phase ratio, and swing phase ratio. There were significant inverse correlations between FIQ and velocity, stride length, swing phase, and single support, whereas significant direct correlations were found with stance phase and double support. Gait parameters of women affected by FM were severely impaired when compared to those of healthy women. Different factors such as lack of physical activity, bradikinesia, overweight, fatigue, and pain together with a lower isometric force in the legs can be responsible for the alterations in gait and poorer life quality of women with FM.

  5. Reliability of diabetic patients' gait parameters in a challenging environment.

    PubMed

    Allet, L; Armand, S; de Bie, R A; Golay, A; Monnin, D; Aminian, K; de Bruin, E D

    2008-11-01

    Activities of daily life require us to move about in challenging environments and to walk on varied surfaces. Irregular terrain has been shown to influence gait parameters, especially in a population at risk for falling. A precise portable measurement system would permit objective gait analysis under such conditions. The aims of this study are to (a) investigate the reliability of gait parameters measured with the Physilog in diabetic patients walking on different surfaces (tar, grass, and stones); (b) identify the measurement error (precision); (c) identify the minimal clinical detectable change. 16 patients with Type 2 diabetes were measured twice within 8 days. After clinical examination patients walked, equipped with a Physilog, on the three aforementioned surfaces. ICC for each surface was excellent for within-visit analyses (>0.938). Inter-visit ICC's (0.753) were excellent except for the knee range parameter (>0.503). The coefficient of variation (CV) was lower than 5% for most of the parameters. Bland and Altman Plots, SEM and SDC showed precise values, distributed around zero for all surfaces. Good reliability of Physilog measurements on different surfaces suggests that Physilog could facilitate the study of diabetic patients' gait in conditions close to real-life situations. Gait parameters during complex locomotor activities (e.g. stair-climbing, curbs, slopes) have not yet been extensively investigated. Good reliability, small measurement error and values of minimal clinical detectable change recommend the utilization of Physilog for the evaluation of gait parameters in diabetic patients.

  6. Gait parameters extraction by using mobile robot equipped with Kinect v2

    NASA Astrophysics Data System (ADS)

    Ogawa, Ami; Mita, Akira; Yorozu, Ayanori; Takahashi, Masaki

    2016-04-01

    The needs for monitoring systems to be used in houses are getting stronger because of the increase of the single household population due to the low birth rate and longevity. Among others, gait parameters are under the spotlight to be examined as the relations with several diseases have been reported. It is known that the gait parameters obtained at a walk test are different from those obtained under the daily life. Thus, the system which can measure the gait parameters in the real living environment is needed. Generally, gait abilities are evaluated by a measurement test, such as Timed Up and Go test and 6-minute walking test. However, these methods need measurers, so the accuracy depends on them and the lack of objectivity is pointed out. Although, a precise motion capture system is used for more objective measurement, it is hard to be used in daily measurement, because the subjects have to put the markers on their body. To solve this problem, marker less sensors, such as Kinect, are developed and used for gait information acquisition. When they are attached to a mobile robot, there is no limitation of distance. However, they still have challenges of calibration for gait parameters, and the important gait parameters to be acquired are not well examined. Therefore, in this study, we extract the important parameters for gait analysis, which have correlations with diseases and age differences, and suggest the gait parameters extraction from depth data by Kinect v2 which is mounted on a mobile robot aiming at applying to the living environment.

  7. Implementation An image processing technique for video motion analysis during the gait cycle canine

    NASA Astrophysics Data System (ADS)

    López, G.; Hernández, J. O.

    2017-01-01

    Nowadays the analyses of human movement, more specifically of the gait have ceased to be a priority for our species. Technological advances and implementations engineering have joined to obtain data and information regarding the gait cycle in another animal species. The aim of this paper is to analyze the canine gait in order to get results that describe the behavior of the limbs during the gait cycle. The research was performed by: 1. Dog training, where it is developed the step of adaptation and trust; 2. Filming gait cycle; 3. Data acquisition, in order to obtain values that describe the motion cycle canine and 4. Results, obtaining the kinematics variables involved in the march. Which are essential to determine the behavior of the limbs, as well as for the development of prosthetic or orthotic. This project was carried out with conventional equipment and using computational tools easily accessible.

  8. Accuracy of the Microsoft Kinect for measuring gait parameters during treadmill walking.

    PubMed

    Xu, Xu; McGorry, Raymond W; Chou, Li-Shan; Lin, Jia-Hua; Chang, Chien-Chi

    2015-07-01

    The measurement of gait parameters normally requires motion tracking systems combined with force plates, which limits the measurement to laboratory settings. In some recent studies, the possibility of using the portable, low cost, and marker-less Microsoft Kinect sensor to measure gait parameters on over-ground walking has been examined. The current study further examined the accuracy level of the Kinect sensor for assessment of various gait parameters during treadmill walking under different walking speeds. Twenty healthy participants walked on the treadmill and their full body kinematics data were measured by a Kinect sensor and a motion tracking system, concurrently. Spatiotemporal gait parameters and knee and hip joint angles were extracted from the two devices and were compared. The results showed that the accuracy levels when using the Kinect sensor varied across the gait parameters. Average heel strike frame errors were 0.18 and 0.30 frames for the right and left foot, respectively, while average toe off frame errors were -2.25 and -2.61 frames, respectively, across all participants and all walking speeds. The temporal gait parameters based purely on heel strike have less error than the temporal gait parameters based on toe off. The Kinect sensor can follow the trend of the joint trajectories for the knee and hip joints, though there was substantial error in magnitudes. The walking speed was also found to significantly affect the identified timing of toe off. The results of the study suggest that the Kinect sensor may be used as an alternative device to measure some gait parameters for treadmill walking, depending on the desired accuracy level. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Markerless identification of key events in gait cycle using image flow.

    PubMed

    Vishnoi, Nalini; Duric, Zoran; Gerber, Naomi Lynn

    2012-01-01

    Gait analysis has been an interesting area of research for several decades. In this paper, we propose image-flow-based methods to compute the motion and velocities of different body segments automatically, using a single inexpensive video camera. We then identify and extract different events of the gait cycle (double-support, mid-swing, toe-off and heel-strike) from video images. Experiments were conducted in which four walking subjects were captured from the sagittal plane. Automatic segmentation was performed to isolate the moving body from the background. The head excursion and the shank motion were then computed to identify the key frames corresponding to different events in the gait cycle. Our approach does not require calibrated cameras or special markers to capture movement. We have also compared our method with the Optotrak 3D motion capture system and found our results in good agreement with the Optotrak results. The development of our method has potential use in the markerless and unencumbered video capture of human locomotion. Monitoring gait in homes and communities provides a useful application for the aged and the disabled. Our method could potentially be used as an assessment tool to determine gait symmetry or to establish the normal gait pattern of an individual.

  10. Reliability of spatial-temporal gait parameters during dual-task interference in people with multiple sclerosis. A cross-sectional study.

    PubMed

    Monticone, Marco; Ambrosini, Emilia; Fiorentini, Roberta; Rocca, Barbara; Liquori, Valentina; Pedrocchi, Alessandra; Ferrante, Simona

    2014-09-01

    To evaluate the reliability and minimum detectable change (MDC) of spatial-temporal gait parameters in subjects with multiple sclerosis (MS) during dual tasking. This cross-sectional study involved 25 healthy subjects (mean age 49.9 ± 15.8 years) and 25 people with MS (mean age 49.2 ± 11.5 years). Gait under motor-cognitive and motor-motor dual tasking conditions was evaluated in two sessions separated by a one-day interval using the GAITRite Walkway System. Test-retest reliability was assessed using intraclass correlation coefficients (ICCs), standard errors of measurement (SEM), and coefficients of variation (CV). MDC scores were computed for the velocity, cadence, step and stride length, step and stride time, double support time, the % of gait cycle for single support and stance phase, and base of support. All of the gait parameters reported good to excellent ICCs under both conditions, with healthy subject values of >0.69 and MS subject values of >0.84. SEM values were always below 18% for both groups of subjects. The gait patterns of the people with MS were slightly more variable than those of the normal controls (CVs: 5.88-41.53% vs 2.84-30.48%). The assessment of quantitative gait parameters in healthy subjects and people with MS is highly reliable under both of the investigated dual tasking conditions. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Effects of conventional overground gait training and a gait trainer with partial body weight support on spatiotemporal gait parameters of patients after stroke

    PubMed Central

    Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Noh, Ji-Woong; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Kim, Junghwan

    2015-01-01

    [Purpose] The purpose of this study was to confirm the effects of both conventional overground gait training (CGT) and a gait trainer with partial body weight support (GTBWS) on spatiotemporal gait parameters of patients with hemiparesis following chronic stroke. [Subjects and Methods] Thirty stroke patients were alternately assigned to one of two treatment groups, and both groups underwent CGT and GTBWS. [Results] The functional ambulation classification on the affected side improved significantly in the CGT and GTBWS groups. Walking speed also improved significantly in both groups. [Conclusion] These results suggest that the GTBWS in company with CGT may be, in part, an effective method of gait training for restoring gait ability in patients after a stroke. PMID:26157272

  12. Effects of conventional overground gait training and a gait trainer with partial body weight support on spatiotemporal gait parameters of patients after stroke.

    PubMed

    Park, Byoung-Sun; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Noh, Ji-Woong; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Kim, Junghwan

    2015-05-01

    [Purpose] The purpose of this study was to confirm the effects of both conventional overground gait training (CGT) and a gait trainer with partial body weight support (GTBWS) on spatiotemporal gait parameters of patients with hemiparesis following chronic stroke. [Subjects and Methods] Thirty stroke patients were alternately assigned to one of two treatment groups, and both groups underwent CGT and GTBWS. [Results] The functional ambulation classification on the affected side improved significantly in the CGT and GTBWS groups. Walking speed also improved significantly in both groups. [Conclusion] These results suggest that the GTBWS in company with CGT may be, in part, an effective method of gait training for restoring gait ability in patients after a stroke.

  13. Cellular Telephone Dialing Influences Kinematic and Spatiotemporal Gait Parameters in Healthy Adults.

    PubMed

    Seymour, Kelly M; Higginson, Christopher I; DeGoede, Kurt M; Bifano, Morgan K; Orr, Rachel; Higginson, Jill S

    2016-01-01

    Gait speed is typically reduced when individuals simultaneously perform other tasks. However, the impact of dual tasking on kinetic and kinematic gait parameters is unclear because these vary with gait speed. The objective of this study was to identify whether dual tasking impacts gait in healthy adults when speed is constant. Twenty-two healthy adults dialed a cell phone during treadmill walking at a self-selected speed while kinetic, kinematic, and spatial parameters were recorded. Results indicated that dual tasking did not impact phone dialing speed, but increased stride width, peak knee flexion during stance, and peak plantarflexion, and decreased knee and ankle range of motion. Dual tasking appears to influence kinematic gait variables in a manner consistent with promotion of stability.

  14. Agreement between the spatio-temporal gait parameters from treadmill-based photoelectric cell and the instrumented treadmill system in healthy young adults and stroke patients.

    PubMed

    Lee, Myungmo; Song, Changho; Lee, Kyoungjin; Shin, Doochul; Shin, Seungho

    2014-07-14

    Treadmill gait analysis was more advantageous than over-ground walking because it allowed continuous measurements of the gait parameters. The purpose of this study was to investigate the concurrent validity and the test-retest reliability of the OPTOGait photoelectric cell system against the treadmill-based gait analysis system by assessing spatio-temporal gait parameters. Twenty-six stroke patients and 18 healthy adults were asked to walk on the treadmill at their preferred speed. The concurrent validity was assessed by comparing data obtained from the 2 systems, and the test-retest reliability was determined by comparing data obtained from the 1st and the 2nd session of the OPTOGait system. The concurrent validity, identified by the intra-class correlation coefficients (ICC [2, 1]), coefficients of variation (CVME), and 95% limits of agreement (LOA) for the spatial-temporal gait parameters, were excellent but the temporal parameters expressed as a percentage of the gait cycle were poor. The test-retest reliability of the OPTOGait System, identified by ICC (3, 1), CVME, 95% LOA, standard error of measurement (SEM), and minimum detectable change (MDC95%) for the spatio-temporal gait parameters, was high. These findings indicated that the treadmill-based OPTOGait System had strong concurrent validity and test-retest reliability. This portable system could be useful for clinical assessments.

  15. Effect of Sacroiliac Joint Manipulation on Selected Gait Parameters in Healthy Subjects.

    PubMed

    Wójtowicz, Sebastian; Sajko, Igor; Hadamus, Anna; Mosiołek, Anna; Białoszewski, Dariusz

    2017-08-31

    The sacroiliac joints have complicated biomechanics. While the movements in the joints are small, they exert a significant effect on gait. This study aimed to assess how sacroiliac joint manipulation influences selected gait parameters. The study enrolled 57 healthy subjects. The experimental group consisted of 26 participants diagnosed with dysfunction of one sacroiliac joint. The control group was composed of 31 persons. All subjects from the experimental group underwent sacroiliac joint manipulation. The experimental group showed significant lengthening of the step on both sides and the stride length in this group increased as well. Moreover, the duration of the stride increased (p=0.000826). The maximum midfoot pressure was higher and maximum heel pressure decreased. The differences were statistically significant. 1. Subclinical dysfunctions of the sacroiliac joints may cause functional gait disturbance. 2. Manipulation of the iliosacral joint exerts a significant effect on gait parameters, which may lead to improved gait economy and effec-tiveness. 3. Following manipulation of one iliosacral joint, altered gait parameters are noted on both the manipulated side and the contralateral side, which may translate into improved quality of locomotion.

  16. Assessment of gait parameters and fatigue in MS patients during inpatient rehabilitation: a pilot trial.

    PubMed

    Sacco, Rosaria; Bussman, Rita; Oesch, Peter; Kesselring, Jürg; Beer, Serafin

    2011-05-01

    Gait impairment and fatigue are common and disabling problems in multiple sclerosis (MS). Characterisation of abnormal gait in MS patients has been done mainly using observational studies and simple walking tests providing only limited quantitative and no qualitative data, or using intricate and time-consuming assessment procedures. In addition, the correlation of gait impairments with fatigue is largely unknown. The aim of this study was to characterise spatio-temporal gait parameters by a simple and easy-to-use gait analysis system (GAITRite®) in MS patients compared with healthy controls, and to analyse changes and correlation with fatigue during inpatient rehabilitation. Twenty-four MS patients (EDSS <6.5) admitted for inpatient rehabilitation and 19 healthy subjects were evaluated using the GAITRite® Functional Ambulation System. Between-group differences and changes of gait parameters during inpatient rehabilitation were analysed, and correlation with fatigue, using the Wurzburg Fatigue Inventory for Multiple Sclerosis (WEIMuS), was determined. Compared to healthy controls MS patients showed significant impairments in different spatio-temporal gait parameters, which showed a significant improvement during inpatient rehabilitation. Different gait parameters were correlated with fatigue physical score, and change of gait parameters was correlated with improvement of fatigue. Spatio-temporal gait analysis is helpful to assess specific walking impairments in MS patients and subtle changes during rehabilitation. Correlation with fatigue may indicate a possible negative impact of fatigue on rehabilitation outcome.

  17. Does a single gait training session performed either overground or on a treadmill induce specific short-term effects on gait parameters in patients with hemiparesis? A randomized controlled study.

    PubMed

    Bonnyaud, Céline; Pradon, Didier; Zory, Raphael; Bensmail, Djamel; Vuillerme, Nicolas; Roche, Nicolas

    2013-01-01

    Gait training for patients with hemiparesis is carried out independently overground or on a treadmill. Several studies have shown differences in hemiparetic gait parameters during overground versus treadmill walking. However, few studies have compared the effects of these 2 gait training conditions on gait parameters, and no study has compared the short-term effects of these techniques on all biomechanical gait parameters. To determine whether a gait training session performed overground or on a treadmill induces specific short-term effects on biomechanical gait parameters in patients with hemiparesis. Twenty-six subjects with hemiparesis were randomly assigned to a single session of either overground or treadmill gait training. The short-term effects on spatiotemporal, kinematic, and kinetic gait parameters were assessed using gait analysis before and immediately after the training and after a 20-minute rest. Speed, cadence, percentage of single support phase, peak knee extension, peak propulsion, and braking on the paretic side were significantly increased after the gait training session. However, there were no specific changes dependent on the type of gait training performed (overground or on a treadmill). A gait training session performed by subjects with hemiparesis overground or on a treadmill did not induce specific short-term effects on biomechanical gait parameters. The increase in gait velocity that followed a gait training session seemed to reflect specific modifications of the paretic lower limb and adaptation of the nonparetic lower limb.

  18. Gait parameters associated with responsiveness to treadmill training with body-weight support after stroke: an exploratory study.

    PubMed

    Mulroy, Sara J; Klassen, Tara; Gronley, JoAnne K; Eberly, Valerie J; Brown, David A; Sullivan, Katherine J

    2010-02-01

    Task-specific training programs after stroke improve walking function, but it is not clear which biomechanical parameters of gait are most associated with improved walking speed. The purpose of this study was to identify gait parameters associated with improved walking speed after a locomotor training program that included body-weight-supported treadmill training (BWSTT). A prospective, between-subjects design was used. Fifteen people, ranging from approximately 9 months to 5 years after stroke, completed 1 of 3 different 6-week training regimens. These regimens consisted of 12 sessions of BWSTT alternated with 12 sessions of: lower-extremity resistive cycling; lower-extremity progressive, resistive strengthening; or a sham condition of arm ergometry. Gait analysis was conducted before and after the 6-week intervention program. Kinematics, kinetics, and electromyographic (EMG) activity were recorded from the hemiparetic lower extremity while participants walked at a self-selected pace. Changes in gait parameters were compared in participants who showed an increase in self-selected walking speed of greater than 0.08 m/s (high-response group) and in those with less improvement (low-response group). Compared with participants in the low-response group, those in the high-response group displayed greater increases in terminal stance hip extension angle and hip flexion power (product of net joint moment and angular velocity) after the intervention. The intensity of soleus muscle EMG activity during walking also was significantly higher in participants in the high-response group after the intervention. Only sagittal-plane parameters were assessed, and the sample size was small. Task-specific locomotor training alternated with strength training resulted in kinematic, kinetic, and muscle activation adaptations that were strongly associated with improved walking speed. Changes in both hip and ankle biomechanics during late stance were associated with greater increases in

  19. Fear of falling and gait parameters in older adults with and without fall history.

    PubMed

    Makino, Keitaro; Makizako, Hyuma; Doi, Takehiko; Tsutsumimoto, Kota; Hotta, Ryo; Nakakubo, Sho; Suzuki, Takao; Shimada, Hiroyuki

    2017-12-01

    Fear of falling (FOF) is associated with spatial and temporal gait parameters in older adults. FOF is prevalent among older adults, both those with and without fall history. It is still unclear whether the relationships between FOF and gait parameters are affected by fall history. The aim of the present study was to compare gait parameters by the presence of FOF and fall history. A total of 3575 older adults (mean age 71.7 years, 49.7% female) met the inclusion criteria for the present study. We assessed the presence of fall history and FOF by face-to-face interview, and gait parameters (gait speed, stride length, step rate, double support time and variation of stride length) at a comfortable speed using a computerized electronic walkway. Prevalences of fall history and FOF were as follows: non-fallers without FOF 52.6% (n = 1881); fallers without FOF 6.3% (n = 227); non-fallers with FOF 34.4% (n = 1229); and fallers with FOF 6.7% (n = 238). Analysis of covariance showed significant differences among the four groups in all gait variables even after adjusting for age, sex and number of medications used. It should be noted that non-fallers with FOF showed significantly slower gait speed, shorter stride length and longer double support time than did non-fallers without FOF (P < 0.001). The present results suggest that spatial and temporal gait parameters are influenced by FOF, even in the absence of fall history. The assessment of FOF might be helpful for better understanding of age-related changes in gait control. Geriatr Gerontol Int 2017; 17: 2455-2459. © 2017 Japan Geriatrics Society.

  20. Pendulum test measure correlates with gait parameters in children with cerebral palsy.

    PubMed

    Lotfian, M; Mirbagheri, M M; Kharazi, M R; Dadashi, F; Nourian, R; Irani, A; Mirbagheri, A

    2016-08-01

    Individuals with cerebral palsy (CP) usually suffer from different impairments including gait impairment and spasticity. Spastic hypertonia is a defining feature of spasticity and manifests as a mechanical abnormality. The objective of this study was to determine the relationship between spastic hypertonia and gait impairments in spastic children with CP, addressing an important controversial issue. Spastic hypertonia was quantified using the pendulum test. The gait impairments were evaluated using the motion capture system in a gait laboratory. Our results showed significant correlations among gait parameters; i.e. walking speed, step length, and the pendulum test measures. This indicates that neuromuscular abnormalities are associated with spasticity and may contribute to gait impairments. The clinical implication is that the impaired gait in children with CP may be improved with the treatment of neuromuscular abnormalities.

  1. Technology-Based Feedback and Its Efficacy in Improving Gait Parameters in Patients with Abnormal Gait: A Systematic Review.

    PubMed

    Chamorro-Moriana, Gema; Moreno, Antonio José; Sevillano, José Luis

    2018-01-06

    This systematic review synthesized and analyzed clinical findings related to the effectiveness of innovative technological feedback for tackling functional gait recovery. An electronic search of PUBMED, PEDro, WOS, CINAHL, and DIALNET was conducted from January 2011 to December 2016. The main inclusion criteria were: patients with modified or abnormal gait; application of technology-based feedback to deal with functional recovery of gait; any comparison between different kinds of feedback applied by means of technology, or any comparison between technological and non-technological feedback; and randomized controlled trials. Twenty papers were included. The populations were neurological patients (75%), orthopedic and healthy subjects. All participants were adults, bar one. Four studies used exoskeletons, 6 load platforms and 5 pressure sensors. The breakdown of the type of feedback used was as follows: 60% visual, 40% acoustic and 15% haptic. 55% used terminal feedback versus 65% simultaneous feedback. Prescriptive feedback was used in 60% of cases, while 50% used descriptive feedback. 62.5% and 58.33% of the trials showed a significant effect in improving step length and speed, respectively. Efficacy in improving other gait parameters such as balance or range of movement is observed in more than 75% of the studies with significant outcomes. Treatments based on feedback using innovative technology in patients with abnormal gait are mostly effective in improving gait parameters and therefore useful for the functional recovery of patients. The most frequently highlighted types of feedback were immediate visual feedback followed by terminal and immediate acoustic feedback.

  2. Changes in spatiotemporal gait parameters following intravenous immunoglobulin treatment for chronic inflammatory demyelinating polyneuropathy.

    PubMed

    Vo, Mary L; Chin, Russell L; Miranda, Caroline; Latov, Norman

    2017-10-01

    Gait impairment is a common presenting symptom in patients with chronic inflammatory demyelinating polyneuropathy (CIDP). However, gait parameters have not previously been evaluated in detail as potential independent outcome measures. We prospectively measured changes in spatiotemporal gait parameters of 20 patients with CIDP at baseline and following treatment with intravenous immunoglobulin (IVIG), using GAITRite® a computerized walkway system with embedded sensors. Overall, study patients showed significant improvements in gait velocity, cadence, stride length, double support time, stance phase, and swing phase following IVIG treatment. Mean changes in velocity, stance phase, and swing phase, exhibited the greatest statistical significance among the subgroup that exhibited clinically meaningful improvement in Inflammatory Neuropathy Cause and Treatment disability score, Medical Research Council sum score, and grip strength. Assessment of gait parameters, in particular velocity, step phase and swing phase, is a potentially sensitive outcome measure for evaluating treatment response in CIDP. Muscle Nerve 56: 732-736, 2017. © 2017 Wiley Periodicals, Inc.

  3. Balance and ankle muscle strength predict spatiotemporal gait parameters in individuals with diabetic peripheral neuropathy.

    PubMed

    Camargo, Marcela R; Barela, José A; Nozabieli, Andréa J L; Mantovani, Alessandra M; Martinelli, Alessandra R; Fregonesi, Cristina E P T

    2015-01-01

    The aims of this study were to evaluate aspects of balance, ankle muscle strength and spatiotemporal gait parameters in individuals with diabetic peripheral neuropathy (DPN) and verify whether deficits in spatiotemporal gait parameters were associated with ankle muscle strength and balance performance. Thirty individuals with DPN and 30 control individuals have participated. Spatiotemporal gait parameters were evaluated by measuring the time to walk a set distance during self-selected and maximal walking speeds. Functional mobility and balance performance were assessed using the Functional Reach and the Time Up and Go tests. Ankle isometric muscle strength was assessed with a handheld digital dynamometer. Analyses of variance were employed to verify possible differences between groups and conditions. Multiple linear regression analysis was employed to uncover possible predictors of gait deficits. Gait spatiotemporal, functional mobility, balance performance and ankle muscle strength were affected in individuals with DPN. The Time Up and Go test performance and ankle muscle isometric strength were associated to spatiotemporal gait changes, especially during maximal walking speed condition. Functional mobility and balance performance are damaged in DPN and balance performance and ankle muscle strength can be used to predict spatiotemporal gait parameters in individuals with DPN. Copyright © 2015 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  4. Technology-Based Feedback and Its Efficacy in Improving Gait Parameters in Patients with Abnormal Gait: A Systematic Review

    PubMed Central

    Chamorro-Moriana, Gema; Moreno, Antonio José

    2018-01-01

    This systematic review synthesized and analyzed clinical findings related to the effectiveness of innovative technological feedback for tackling functional gait recovery. An electronic search of PUBMED, PEDro, WOS, CINAHL, and DIALNET was conducted from January 2011 to December 2016. The main inclusion criteria were: patients with modified or abnormal gait; application of technology-based feedback to deal with functional recovery of gait; any comparison between different kinds of feedback applied by means of technology, or any comparison between technological and non-technological feedback; and randomized controlled trials. Twenty papers were included. The populations were neurological patients (75%), orthopedic and healthy subjects. All participants were adults, bar one. Four studies used exoskeletons, 6 load platforms and 5 pressure sensors. The breakdown of the type of feedback used was as follows: 60% visual, 40% acoustic and 15% haptic. 55% used terminal feedback versus 65% simultaneous feedback. Prescriptive feedback was used in 60% of cases, while 50% used descriptive feedback. 62.5% and 58.33% of the trials showed a significant effect in improving step length and speed, respectively. Efficacy in improving other gait parameters such as balance or range of movement is observed in more than 75% of the studies with significant outcomes. Conclusion: Treatments based on feedback using innovative technology in patients with abnormal gait are mostly effective in improving gait parameters and therefore useful for the functional recovery of patients. The most frequently highlighted types of feedback were immediate visual feedback followed by terminal and immediate acoustic feedback. PMID:29316645

  5. Asymmetry of short-term control of spatio-temporal gait parameters during treadmill walking

    NASA Astrophysics Data System (ADS)

    Kozlowska, Klaudia; Latka, Miroslaw; West, Bruce J.

    2017-03-01

    Optimization of energy cost determines average values of spatio-temporal gait parameters such as step duration, step length or step speed. However, during walking, humans need to adapt these parameters at every step to respond to exogenous and/or endogenic perturbations. While some neurological mechanisms that trigger these responses are known, our understanding of the fundamental principles governing step-by-step adaptation remains elusive. We determined the gait parameters of 20 healthy subjects with right-foot preference during treadmill walking at speeds of 1.1, 1.4 and 1.7 m/s. We found that when the value of the gait parameter was conspicuously greater (smaller) than the mean value, it was either followed immediately by a smaller (greater) value of the contralateral leg (interleg control), or the deviation from the mean value decreased during the next movement of ipsilateral leg (intraleg control). The selection of step duration and the selection of step length during such transient control events were performed in unique ways. We quantified the symmetry of short-term control of gait parameters and observed the significant dominance of the right leg in short-term control of all three parameters at higher speeds (1.4 and 1.7 m/s).

  6. Trans-tibial amputee gait: time-distance parameters and EMG activity.

    PubMed

    Isakov, E; Keren, O; Benjuya, N

    2000-12-01

    Gait analysis of trans-tibial (TT) amputees discloses asymmetries in gait parameters between the amputated and sound legs. The present study aimed at outlining differences between both legs with regard to kinematic parameters and activity of the muscles controlling the knees. The gait of 14 traumatic TT amputees, walking at a mean speed of 74.96 m/min, was analysed by means of an electronic walkway, video camera, and portable electromyography system. Results showed differences in kinematic parameters. Step length, step time and swing time were significantly longer, while stance time and single support time were significantly shorter on the amputated side. A significant difference was also found between knee angle in both legs at heel strike. The biceps femoris/vastus medialis ratio in the amputated leg, during the first half of stance phase, was significantly higher when compared to the same muscle ratio in the sound leg. This difference was due to the higher activity of the biceps femoris, almost four times higher than the vastus medialis in the amputated leg. The observed differences in time-distance parameters are due to stiffness of the prosthesis ankle (the SACH foot) that impedes the normal forward advance of the amputated leg during the first half of stance. The higher knee flexion at heel strike is due to the necessary socket alignment. Unlike in the sound leg, the biceps femoris in the amputated leg reaches maximal activity during the first half of stance, cocontracting with the vastus medialis, to support body weight on the amputated leg. The obtained data can serve as a future reference for evaluating the influence of new prosthetic components on the quality of TT amputee's gait.

  7. Kinetic and temporospatial gait parameters in a heterogeneous group of dogs.

    PubMed

    Kano, Washington T; Rahal, Sheila C; Agostinho, Felipe S; Mesquita, Luciane R; Santos, Rogerio R; Monteiro, Frederico O B; Castilho, Maira S; Melchert, Alessandra

    2016-01-04

    A prime concern of the gait analysis in a heterogeneous group of dogs is the potential influence of factors such as individual body size, body mass, type of gait, and velocity. Thus, this study aimed to evaluate in a heterogeneous group of dogs a possible correlation of the stride frequency with kinetic and temporospatial variables, as well as the percentage of body weight distribution (%BWD), and compare symmetry index (SI) between trotting and walking dogs. Twenty-nine clinically healthy dogs moving in a controlled velocity were used. The dogs were organized into two groups based on duty factor. Group 1 comprised 15 walking dogs, aged from 9 months to 8 years and weighing about 22.3 kg. Group 2 had 14 trotting dogs, aged from 1 to 6 years and weighing about 6.5 kg. The kinetic data and temporospatial parameters were obtained using a pressure-sensing walkway. The velocity was 0.9-1.1 m/s. The peak vertical force (PVF), vertical impulse (VI), gait cycle time, stance time, swing time, stride length, and percentages of body weight distribution among the four limbs were determined. For each variable, the SIs were calculated. Pearson's coefficient was used to evaluate correlation between stride frequency and other variables, initially in each group and after including all animals. Except for the %BWD (approximately 60% for the forelimbs and 40% for the hind limbs), all other parameters differed between groups. Considering each Group individually a strong correlation was observed for most of the temporospatial parameters, but no significant correlation occurred between stride frequency and PVF, and stride frequency and %BWD. However, including all dogs a strong correlation was observed in all temporospatial parameters, and moderate correlation between stride frequency and VI, and weak correlation between stride frequency and PVF. There was no correlation between stride frequency and %BWD. Groups 1 and 2 did not differ statistically in SIs. In a heterogeneous group of

  8. Gait cycle analysis: parameters sensitive for functional evaluation of peripheral nerve recovery in rat hind limbs.

    PubMed

    Rui, Jing; Runge, M Brett; Spinner, Robert J; Yaszemski, Michael J; Windebank, Anthony J; Wang, Huan

    2014-10-01

    Video-assisted gait kinetics analysis has been a sensitive method to assess rat sciatic nerve function after injury and repair. However, in conduit repair of sciatic nerve defects, previously reported kinematic measurements failed to be a sensitive indicator because of the inferior recovery and inevitable joint contracture. This study aimed to explore the role of physiotherapy in mitigating joint contracture and to seek motion analysis indices that can sensitively reflect motor function. Data were collected from 26 rats that underwent sciatic nerve transection and conduit repair. Regular postoperative physiotherapy was applied. Parameters regarding step length, phase duration, and ankle angle were acquired and analyzed from video recording of gait kinetics preoperatively and at regular postoperative intervals. Stride length ratio (step length of uninjured foot/step length of injured foot), percent swing of the normal paw (percentage of the total stride duration when the uninjured paw is in the air), propulsion angle (toe-off angle subtracted by midstance angle), and clearance angle (ankle angle change from toe off to midswing) decreased postoperatively comparing with baseline values. The gradual recovery of these measurements had a strong correlation with the post-nerve repair time course. Ankle joint contracture persisted despite rigorous physiotherapy. Parameters acquired from a 2-dimensional motion analysis system, that is, stride length ratio, percent swing of the normal paw, propulsion angle, and clearance angle, could sensitively reflect nerve function impairment and recovery in the rat sciatic nerve conduit repair model despite the existence of joint contractures.

  9. A novel biofeedback cycling training to improve gait symmetry in stroke patients: a case series study.

    PubMed

    Ambrosini, Emilia; Ferrante, Simona; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Guanziroli, Eleonora; Molteni, Franco

    2011-01-01

    The restoration of walking ability is crucial for maximizing independent mobility among patients with stroke. Leg cycling is becoming an established intervention to supplement ambulation training for stroke patients with problems of unbalance and weakness. The aim of the study was to explore the feasibility of a biofeedback pedaling treatment and its effects on cycling and walking ability in chronic stroke patients. Three patients were included in the study. The training consisted of a 2-week treatment of 6 sessions, during which a visual biofeedback helped the participants in maintaining a symmetrical pedaling. Participants were assessed before, after training and at follow-up, by means of a pedaling test and gait analysis. Outcome measurements were the unbalance during pedaling, the temporal, spatial and symmetry parameters during walking. An intra-subject statistical analysis (ANOVA, p<;0.05) showed that all patients significantly decreased pedaling unbalance after treatment and maintained the improvements at follow-up. The training induced some gait pattern modifications in two patients: one significantly improved mean velocity and gait symmetry, while the other one reduced the compensation strategy of the healthy leg. The results demonstrated the feasibility of the treatment. If further trials on a larger and controlled scale confirmed the same results, this treatment, thanks to its safety and low price, could have a significant impact as a home-rehabilitation treatment. © 2011 IEEE

  10. Concurrent validity of the Microsoft Kinect for Windows v2 for measuring spatiotemporal gait parameters.

    PubMed

    Dolatabadi, Elham; Taati, Babak; Mihailidis, Alex

    2016-09-01

    This paper presents a study to evaluate the concurrent validity of the Microsoft Kinect for Windows v2 for measuring the spatiotemporal parameters of gait. Twenty healthy adults performed several sequences of walks across a GAITRite mat under three different conditions: usual pace, fast pace, and dual task. Each walking sequence was simultaneously captured with two Kinect for Windows v2 and the GAITRite system. An automated algorithm was employed to extract various spatiotemporal features including stance time, step length, step time and gait velocity from the recorded Kinect v2 sequences. Accuracy in terms of reliability, concurrent validity and limits of agreement was examined for each gait feature under different walking conditions. The 95% Bland-Altman limits of agreement were narrow enough for the Kinect v2 to be a valid tool for measuring all reported spatiotemporal parameters of gait in all three conditions. An excellent intraclass correlation coefficient (ICC2, 1) ranging from 0.9 to 0.98 was observed for all gait measures across different walking conditions. The inter trial reliability of all gait parameters were shown to be strong for all walking types (ICC3, 1 > 0.73). The results of this study suggest that the Kinect for Windows v2 has the capacity to measure selected spatiotemporal gait parameters for healthy adults. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Prediction of human gait parameters from temporal measures of foot-ground contact

    NASA Technical Reports Server (NTRS)

    Breit, G. A.; Whalen, R. T.

    1997-01-01

    Investigation of the influence of human physical activity on bone functional adaptation requires long-term histories of gait-related ground reaction force (GRF). Towards a simpler portable GRF measurement, we hypothesized that: 1) the reciprocal of foot-ground contact time (1/tc); or 2) the reciprocal of stride-period-normalized contact time (T/tc) predict peak vertical and horizontal GRF, loading rates, and horizontal speed during gait. GRF data were collected from 24 subjects while they walked and ran at a variety of speeds. Linear regression and ANCOVA determined the dependence of gait parameters on 1/tc and T/tc, and prediction SE. All parameters were significantly correlated to 1/tc and T/tc. The closest pooled relationship existed between peak running vertical GRF and T/tc (r2 = 0.896; SE = 3.6%) and improved with subject-specific regression (r2 = 0.970; SE = 2.2%). We conclude that temporal measures can predict force parameters of gait and may represent an alternative to direct GRF measurements for determining daily histories of habitual lower limb loading quantities necessary to quantify a bone remodeling stimulus.

  12. Design, simulation and modelling of auxiliary exoskeleton to improve human gait cycle.

    PubMed

    Ashkani, O; Maleki, A; Jamshidi, N

    2017-03-01

    Exoskeleton is a walking assistance device that improves human gait cycle through providing auxiliary force and transferring physical load to the stronger muscles. This device takes the natural state of organ and follows its natural movement. Exoskeleton functions as an auxiliary device to help those with disabilities in hip and knee such as devotees, elderly farmers and agricultural machinery operators who suffer from knee complications. In this research, an exoskeleton designed with two screw jacks at knee and hip joints. To simulate extension and flexion movements of the leg joints, bearings were used at the end of hip and knee joints. The generated torque and motion angles of these joints obtained as well as the displacement curves of screw jacks in the gait cycle. Then, the human gait cycle was simulated in stance and swing phases and the obtained torque curves were compared. The results indicated that they followed the natural circle of the generated torque in joints with a little difference from each other. The maximum displacement obtained 4 and 6 cm in hip and knee joints jack respectively. The maximum torques in hip and knee joints were generated in foot contact phase. Also the minimum torques in hip and knee joints were generated in toe off and heel off phases respectively.

  13. Variations in Kinematics during Clinical Gait Analysis in Stroke Patients

    PubMed Central

    Boudarham, Julien; Roche, Nicolas; Pradon, Didier; Bonnyaud, Céline; Bensmail, Djamel; Zory, Raphael

    2013-01-01

    In addition to changes in spatio-temporal and kinematic parameters, patients with stroke exhibit fear of falling as well as fatigability during gait. These changes could compromise interpretation of data from gait analysis. The aim of this study was to determine if the gait of hemiplegic patients changes significantly over successive gait trials. Forty two stroke patients and twenty healthy subjects performed 9 gait trials during a gait analysis session. The mean and variability of spatio-temporal and kinematic joint parameters were analyzed during 3 groups of consecutive gait trials (1–3, 4–6 and 7–9). Principal component analysis was used to reduce the number of variables from the joint kinematic waveforms and to identify the parts of the gait cycle which changed during the gait analysis session. The results showed that i) spontaneous gait velocity and the other spatio-temporal parameters significantly increased, and ii) gait variability decreased, over the last 6 gait trials compared to the first 3, for hemiplegic patients but not healthy subjects. Principal component analysis revealed changes in the sagittal waveforms of the hip, knee and ankle for hemiplegic patients after the first 3 gait trials. These results suggest that at the beginning of the gait analysis session, stroke patients exhibited phase of adaptation,characterized by a “cautious gait” but no fatigue was observed. PMID:23799100

  14. Gait-Cycle-Driven Transmission Power Control Scheme for a Wireless Body Area Network.

    PubMed

    Zang, Weilin; Li, Ye

    2018-05-01

    In a wireless body area network (WBAN), walking movements can result in rapid channel fluctuations, which severely degrade the performance of transmission power control (TPC) schemes. On the other hand, these channel fluctuations are often periodic and are time-synchronized with the user's gait cycle, since they are all driven from the walking movements. In this paper, we propose a novel gait-cycle-driven transmission power control (G-TPC) for a WBAN. The proposed G-TPC scheme reinforces the existing TPC scheme by exploiting the periodic channel fluctuation in the walking scenario. In the proposed scheme, the user's gait cycle information acquired by an accelerometer is used as beacons for arranging the transmissions at the time points with the ideal channel state. The specific transmission power is then determined by using received signal strength indication (RSSI). An experiment was conducted to evaluate the energy efficiency and reliability of the proposed G-TPC based on a CC2420 platform. The results reveal that compared to the original RSSI/link-quality-indication-based TPC, G-TPC reduces energy consumption by 25% on the sensor node and reduce the packet loss rate by 65%.

  15. Analysis of spastic gait in cervical myelopathy: Linking compression ratio to spatiotemporal and pedobarographic parameters.

    PubMed

    Nagai, Taro; Takahashi, Yasuhito; Endo, Kenji; Ikegami, Ryo; Ueno, Ryuichi; Yamamoto, Kengo

    2018-01-01

    Gait dysfunction associated with spasticity and hyperreflexia is a primary symptom in patients with compression of cervical spinal cord. The objective of this study was to link maximum compression ratio (CR) to spatiotemporal/pedobarographic parameters. Quantitative gait analysis was performed by using a pedobarograph in 75 elderly males with a wide range of cervical compression severity. CR values were characterized on T1-weighted magnetic resonance imaging (MRI). Statistical significances in gait analysis parameters (speed, cadence, stride length, step with, and toe-out angle) were evaluated among different CR groups by the non-parametric Kruskal-Wallis test followed by the Mann-Whitney U test using Bonferroni correction. The Spearman test was performed to verify correlations between CR and gait parameters. The Kruskal-Wallis test revealed significant decline in gait speed and stride length and significant increase in toe-out angle with progression of cervical compression myelopathy. The post-hoc Mann-Whitney U test showed significant differences in these parameters between the control group (0.45Gait speed, stride length, and toe-out angle can serve as useful indexes for evaluating progressive gait abnormality in cervical myelopathy. Our findings suggest that CR≤0.25 is associated with significantly poorer gait performance. Nevertheless, future prospective studies are needed to determine a potential benefit from decompressive surgery in such severe compression patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Associations between results of post-stroke NDT-Bobath rehabilitation in gait parameters, ADL and hand functions.

    PubMed

    Mikołajewska, Emilia

    2013-01-01

    In patients after a stroke there are variable disorders. These patients often need rehabilitation in more than one area beceause of multiple limitations of the ability to perform everyday activities. The aim of the study was to assess correlations - statistical relationships between observed gait parameters, ADL and hand functions - results of rehabilitation of patients after ischaemic stroke according to the NDTBobath method for adults. The investigated group consisted of 60 patients after ischaemic stroke, who participated in the rehabilitation programme. 10 sessions of the NDT-Bobath therapy were provided in 2 weeks (10 days of the therapy). The calculation of correlations was made based on changes of parameters: Bobath Scale (to assess hand functions), Barthel Index (to assess ADL), gait velocity, cadence and stride lenght. Measurements were performed in every patient twice: on admission (before the therapy) and after last session of the therapy to assess rehabilitation effects. The main statistically relevant corellations observed in the study were as follows: in the whole group of patients: poor and moderate (negative) correlation between changes of gait parameters and Bobath Scale and Barthel Index, moderate and severe (negative) correlation between changes of gait parameters and Bobath Scale and Barthel Index in the group of women, correlation between changes in Bobath Scale and Barthel Index in the group of patients with left side of paresis, (negative) correlation between changes of gait parameters and Bobath Scale in group of patients younger than 68 years, moderate, high and very high correlations between changes in gait parameters in groups of women, men, younger than 68 years and older than 68 years. There have been observed statistically significant and favourable changes in the health status of patients, described by gait parameters, changes in hand functions and ADL. Based on the presented correlations there is an assumption that it is hard to

  17. Influence of dual task and frailty on gait parameters of older community-dwelling individuals

    PubMed Central

    Guedes, Rita C.; Dias, Rosângela C.; Pereira, Leani S. M.; Silva, Sílvia L. A.; Lustosa, Lygia P.; Dias, João M. D.

    2014-01-01

    Background: Gait parameters such as gait speed (GS) are important indicators of functional capacity. Frailty Syndrome is closely related to GS and is also capable of predicting adverse outcomes. The cognitive demand of gait control is usually explored with dual-task (DT) methodology. Objective: To investigate the effect of DT and frailty on the spatio-temporal parameters of gait in older people and identify which variables relate to GS. Method: The presence of frailty was verified by Fried's Frailty Criteria. Cognitive function was evaluated with the Mini-Mental State Exam (MMSE) and gait parameters were analyzed through the GAITRite(r) system in the single-task and DT conditions. The Kolmogorov-Smirnov, ANOVA, and Pearson's Correlation tests were administered. Results: The participants were assigned to the groups frail (FG), pre-frail (PFG), and non-frail (NFG). During the DT, the three groups showed a decrease in GS, cadence, and stride length and an increase in stride time (p<0.001). The reduction in the GS of the FG during the DT showed a positive correlation with the MMSE scores (r=730; p=0.001) and with grip strength (r=681; p=0.001). Conclusions: Gait parameters are more affected by the DT, especially in the frail older subjects. The reduction in GS in the FG is associated with lower grip strength and lower scores in the MMSE. The GS was able to discriminate the older adults in the three levels of frailty, being an important measure of the functional capacity in this population. PMID:25372007

  18. Model Predictive Control-based gait pattern generation for wearable exoskeletons.

    PubMed

    Wang, Letian; van Asseldonk, Edwin H F; van der Kooij, Herman

    2011-01-01

    This paper introduces a new method for controlling wearable exoskeletons that do not need predefined joint trajectories. Instead, it only needs basic gait descriptors such as step length, swing duration, and walking speed. End point Model Predictive Control (MPC) is used to generate the online joint trajectories based on these gait parameters. Real-time ability and control performance of the method during the swing phase of gait cycle is studied in this paper. Experiments are performed by helping a human subject swing his leg with different patterns in the LOPES gait trainer. Results show that the method is able to assist subjects to make steps with different step length and step duration without predefined joint trajectories and is fast enough for real-time implementation. Future study of the method will focus on controlling the exoskeletons in the entire gait cycle. © 2011 IEEE

  19. Intra-rater repeatability of gait parameters in healthy adults during self-paced treadmill-based virtual reality walking.

    PubMed

    Al-Amri, Mohammad; Al Balushi, Hilal; Mashabi, Abdulrhman

    2017-12-01

    Self-paced treadmill walking is becoming increasingly popular for the gait assessment and re-education, in both research and clinical settings. Its day-to-day repeatability is yet to be established. This study scrutinised the test-retest repeatability of key gait parameters, obtained from the Gait Real-time Analysis Interactive Lab (GRAIL) system. Twenty-three male able-bodied adults (age: 34.56 ± 5.12 years) completed two separate gait assessments on the GRAIL system, separated by 5 ± 3 days. Key gait kinematic, kinetic, and spatial-temporal parameters were analysed. The Intraclass-Correlation Coefficients (ICC), Standard Error Measurement (SEM), Minimum Detectable Change (MDC), and the 95% limits of agreements were calculated to evaluate the repeatability of these gait parameters. Day-to-day agreements were excellent (ICCs > 0.87) for spatial-temporal parameters with low MDC and SEM values, <0.153 and <0.055, respectively. The repeatability was higher for joint kinetic than kinematic parameters, as reflected in small values of SEM (<0.13 Nm/kg and <3.4°) and MDC (<0.335 Nm/kg and <9.44°). The obtained values of all parameters fell within the 95% limits of agreement. Our findings demonstrate the repeatability of the GRAIL system available in our laboratory. The SEM and MDC values can be used to assist researchers and clinicians to distinguish 'real' changes in gait performance over time.

  20. Clinical assessment of spatiotemporal gait parameters in patients and older adults.

    PubMed

    Item-Glatthorn, Julia F; Maffiuletti, Nicola A

    2014-11-07

    Spatial and temporal characteristics of human walking are frequently evaluated to identify possible gait impairments, mainly in orthopedic and neurological patients, but also in healthy older adults. The quantitative gait analysis described in this protocol is performed with a recently-introduced photoelectric system (see Materials table) which has the potential to be used in the clinic because it is portable, easy to set up (no subject preparation is required before a test), and does not require maintenance and sensor calibration. The photoelectric system consists of series of high-density floor-based photoelectric cells with light-emitting and light-receiving diodes that are placed parallel to each other to create a corridor, and are oriented perpendicular to the line of progression. The system simply detects interruptions in light signal, for instance due to the presence of feet within the recording area. Temporal gait parameters and 1D spatial coordinates of consecutive steps are subsequently calculated to provide common gait parameters such as step length, single limb support and walking velocity, whose validity against a criterion instrument has recently been demonstrated. The measurement procedures are very straightforward; a single patient can be tested in less than 5 min and a comprehensive report can be generated in less than 1 min.

  1. Normal human gait patterns in Peruvian individuals: an exploratory assessment using VICON motion capture system

    NASA Astrophysics Data System (ADS)

    Dongo, R.; Moscoso, M.; Callupe, R.; Pajaya, J.; Elías, D.

    2017-11-01

    Gait analysis is of clinical relevance for clinicians. However, normal gait patterns used in foreign literature could be different from local individuals. The aim of this study was to determine the normal gait patterns and parameters of Peruvian individuals in order to have a local referent for clinical assessments and making diagnosis and treatment Peruvian people with lower motor neuron injuries. A descriptive study with 34 subjects was conducted to assess their gait cycle. VICON® cameras were used to capture body movements. For the analyses, we calculated spatiotemporal gait parameters and average angles of displacement of the hip, knee, and ankle joints with their respective 95% confidence intervals. The results showed gait speed was 0.58m/s, cadence was 102.1steps/min, and the angular displacement of the hip, knee and ankle joints were all lower than those described in the literature. In the graphs, gait cycles were close to those reported in previous studies, but the parameters of speed, cadence and angles of displacements are lower than the ones shown in the literature. These results could be used as a better reference pattern in the clinical setting.

  2. Neuromorphic walking gait control.

    PubMed

    Still, Susanne; Hepp, Klaus; Douglas, Rodney J

    2006-03-01

    We present a neuromorphic pattern generator for controlling the walking gaits of four-legged robots which is inspired by central pattern generators found in the nervous system and which is implemented as a very large scale integrated (VLSI) chip. The chip contains oscillator circuits that mimic the output of motor neurons in a strongly simplified way. We show that four coupled oscillators can produce rhythmic patterns with phase relationships that are appropriate to generate all four-legged animal walking gaits. These phase relationships together with frequency and duty cycle of the oscillators determine the walking behavior of a robot driven by the chip, and they depend on a small set of stationary bias voltages. We give analytic expressions for these dependencies. This chip reduces the complex, dynamic inter-leg control problem associated with walking gait generation to the problem of setting a few stationary parameters. It provides a compact and low power solution for walking gait control in robots.

  3. 3D gait assessment in young and elderly subjects using foot-worn inertial sensors.

    PubMed

    Mariani, Benoit; Hoskovec, Constanze; Rochat, Stephane; Büla, Christophe; Penders, Julien; Aminian, Kamiar

    2010-11-16

    This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. New Lower-Limb Gait Asymmetry Indices Based on a Depth Camera

    PubMed Central

    Auvinet, Edouard; Multon, Franck; Meunier, Jean

    2015-01-01

    Background: Various asymmetry indices have been proposed to compare the spatiotemporal, kinematic and kinetic parameters of lower limbs during the gait cycle. However, these indices rely on gait measurement systems that are costly and generally require manual examination, calibration procedures and the precise placement of sensors/markers on the body of the patient. Methods: To overcome these issues, this paper proposes a new asymmetry index, which uses an inexpensive, easy-to-use and markerless depth camera (Microsoft Kinect™) output. This asymmetry index directly uses depth images provided by the Kinect™ without requiring joint localization. It is based on the longitudinal spatial difference between lower-limb movements during the gait cycle. To evaluate the relevance of this index, fifteen healthy subjects were tested on a treadmill walking normally and then via an artificially-induced gait asymmetry with a thick sole placed under one shoe. The gait movement was simultaneously recorded using a Kinect™ placed in front of the subject and a motion capture system. Results: The proposed longitudinal index distinguished asymmetrical gait (p < 0.001), while other symmetry indices based on spatiotemporal gait parameters failed using such Kinect™ skeleton measurements. Moreover, the correlation coefficient between this index measured by Kinect™ and the ground truth of this index measured by motion capture is 0.968. Conclusion: This gait asymmetry index measured with a Kinect™ is low cost, easy to use and is a promising development for clinical gait analysis. PMID:25719863

  5. Effect of rhythmic auditory stimulation on gait kinematic parameters of patients with multiple sclerosis.

    PubMed

    Shahraki, M; Sohrabi, M; Taheri Torbati, H R; Nikkhah, K; NaeimiKia, M

    2017-01-01

    Purpose: This study aimed to examine the effect of rhythmic auditory stimulation on gait kinematic parameters of patients with multiple sclerosis. Subjects and Methods: In this study, 18 subjects, comprising 4 males and 14 females with Multiple Sclerosis with expanded disability status scale of 3 to 6 were chosen. Subjects were selected by available and targeted sampling and were randomly divided into two experimental (n = 9) and control (n = 9) groups. Exercises were gait with rhythmic auditory stimulation by a metronome device, in addition to gait without stimulation for the experimental and control groups, respectively. Training was carried out for 3 weeks, with 30 min duration for each session 3 times a week. Stride length, stride time, double support time, cadence and gait speed were measured by motion analysis device. Results: There was a significant difference between stride length, stride time, double support time, cadence and gait speed in the experimental group, before and after the training. Furthermore, there was a significant difference between the experimental and control groups in the enhancement of stride length, stride time, cadence and gait speed in favor of the experimental group. While this difference was not significant for double support time. Conclusion: The results of this study showed that rhythmic auditory stimulation is an effective rehabilitation method to improve gait kinematic parameters in patients with multiple sclerosis.

  6. Sensitivity of subject-specific models to Hill muscle-tendon model parameters in simulations of gait.

    PubMed

    Carbone, V; van der Krogt, M M; Koopman, H F J M; Verdonschot, N

    2016-06-14

    Subject-specific musculoskeletal (MS) models of the lower extremity are essential for applications such as predicting the effects of orthopedic surgery. We performed an extensive sensitivity analysis to assess the effects of potential errors in Hill muscle-tendon (MT) model parameters for each of the 56 MT parts contained in a state-of-the-art MS model. We used two metrics, namely a Local Sensitivity Index (LSI) and an Overall Sensitivity Index (OSI), to distinguish the effect of the perturbation on the predicted force produced by the perturbed MT parts and by all the remaining MT parts, respectively, during a simulated gait cycle. Results indicated that sensitivity of the model depended on the specific role of each MT part during gait, and not merely on its size and length. Tendon slack length was the most sensitive parameter, followed by maximal isometric muscle force and optimal muscle fiber length, while nominal pennation angle showed very low sensitivity. The highest sensitivity values were found for the MT parts that act as prime movers of gait (Soleus: average OSI=5.27%, Rectus Femoris: average OSI=4.47%, Gastrocnemius: average OSI=3.77%, Vastus Lateralis: average OSI=1.36%, Biceps Femoris Caput Longum: average OSI=1.06%) and hip stabilizers (Gluteus Medius: average OSI=3.10%, Obturator Internus: average OSI=1.96%, Gluteus Minimus: average OSI=1.40%, Piriformis: average OSI=0.98%), followed by the Peroneal muscles (average OSI=2.20%) and Tibialis Anterior (average OSI=1.78%) some of which were not included in previous sensitivity studies. Finally, the proposed priority list provides quantitative information to indicate which MT parts and which MT parameters should be estimated most accurately to create detailed and reliable subject-specific MS models. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Changes in the gait characteristics caused by external load, ground slope and velocity variation

    NASA Astrophysics Data System (ADS)

    Mrozowski, Jerzy; Awrejcewicz, Jan

    2011-05-01

    The complexity of the human gait manifests itself by lots of parameters that can evoke different changes in the walking manner. They can be divided into two groups: inherent, like anthropometric features or peculiar psychomotor type, and those related to the external conditions. The aim of the paper is to analyze the influence of three parameters, i.e. external load, ground slope and gait velocity, on the locomotion characteristics and the gait stability. Within the framework of investigations for different values of the mentioned parameters a film registration of the trajectories of selected kinematic nodes during some gait cycles has been carried out. The obtained data was a subject of numerical calculation aimed at extracting the essential properties of the principal gait characteristics.

  8. Gait parameters are differently affected by concurrent smartphone-based activities with scaled levels of cognitive effort.

    PubMed

    Caramia, Carlotta; Bernabucci, Ivan; D'Anna, Carmen; De Marchis, Cristiano; Schmid, Maurizio

    2017-01-01

    The widespread and pervasive use of smartphones for sending messages, calling, and entertainment purposes, mainly among young adults, is often accompanied by the concurrent execution of other tasks. Recent studies have analyzed how texting, reading or calling while walking-in some specific conditions-might significantly influence gait parameters. The aim of this study is to examine the effect of different smartphone activities on walking, evaluating the variations of several gait parameters. 10 young healthy students (all smartphone proficient users) were instructed to text chat (with two different levels of cognitive load), call, surf on a social network or play with a math game while walking in a real-life outdoor setting. Each of these activities is characterized by a different cognitive load. Using an inertial measurement unit on the lower trunk, spatio-temporal gait parameters, together with regularity, symmetry and smoothness parameters, were extracted and grouped for comparison among normal walking and different dual task demands. An overall significant effect of task type on the aforementioned parameters group was observed. The alterations in gait parameters vary as a function of cognitive effort. In particular, stride frequency, step length and gait speed show a decrement, while step time increases as a function of cognitive effort. Smoothness, regularity and symmetry parameters are significantly altered for specific dual task conditions, mainly along the mediolateral direction. These results may lead to a better understanding of the possible risks related to walking and concurrent smartphone use.

  9. Gait parameters are differently affected by concurrent smartphone-based activities with scaled levels of cognitive effort

    PubMed Central

    Bernabucci, Ivan; D'Anna, Carmen; De Marchis, Cristiano; Schmid, Maurizio

    2017-01-01

    The widespread and pervasive use of smartphones for sending messages, calling, and entertainment purposes, mainly among young adults, is often accompanied by the concurrent execution of other tasks. Recent studies have analyzed how texting, reading or calling while walking–in some specific conditions–might significantly influence gait parameters. The aim of this study is to examine the effect of different smartphone activities on walking, evaluating the variations of several gait parameters. 10 young healthy students (all smartphone proficient users) were instructed to text chat (with two different levels of cognitive load), call, surf on a social network or play with a math game while walking in a real-life outdoor setting. Each of these activities is characterized by a different cognitive load. Using an inertial measurement unit on the lower trunk, spatio-temporal gait parameters, together with regularity, symmetry and smoothness parameters, were extracted and grouped for comparison among normal walking and different dual task demands. An overall significant effect of task type on the aforementioned parameters group was observed. The alterations in gait parameters vary as a function of cognitive effort. In particular, stride frequency, step length and gait speed show a decrement, while step time increases as a function of cognitive effort. Smoothness, regularity and symmetry parameters are significantly altered for specific dual task conditions, mainly along the mediolateral direction. These results may lead to a better understanding of the possible risks related to walking and concurrent smartphone use. PMID:29023456

  10. Estimation of Temporal Gait Parameters Using a Human Body Electrostatic Sensing-Based Method.

    PubMed

    Li, Mengxuan; Li, Pengfei; Tian, Shanshan; Tang, Kai; Chen, Xi

    2018-05-28

    Accurate estimation of gait parameters is essential for obtaining quantitative information on motor deficits in Parkinson's disease and other neurodegenerative diseases, which helps determine disease progression and therapeutic interventions. Due to the demand for high accuracy, unobtrusive measurement methods such as optical motion capture systems, foot pressure plates, and other systems have been commonly used in clinical environments. However, the high cost of existing lab-based methods greatly hinders their wider usage, especially in developing countries. In this study, we present a low-cost, noncontact, and an accurate temporal gait parameters estimation method by sensing and analyzing the electrostatic field generated from human foot stepping. The proposed method achieved an average 97% accuracy on gait phase detection and was further validated by comparison to the foot pressure system in 10 healthy subjects. Two results were compared using the Pearson coefficient r and obtained an excellent consistency ( r = 0.99, p < 0.05). The repeatability of the purposed method was calculated between days by intraclass correlation coefficients (ICC), and showed good test-retest reliability (ICC = 0.87, p < 0.01). The proposed method could be an affordable and accurate tool to measure temporal gait parameters in hospital laboratories and in patients' home environments.

  11. Using gait parameters to detect fatigue and responses to ice slurry during prolonged load carriage.

    PubMed

    Tay, Cheryl S; Lee, Jason K W; Teo, Ya S; Foo, Phildia Q Z; Tan, Pearl M S; Kong, Pui W

    2016-01-01

    This study examined (1) if changes in gait characteristics could indicate the exertional heat stress experienced during prolonged load carriage, and (2) if gait characteristics were responsive to a heat mitigation strategy. In an environmental chamber replicating tropical climatic conditions (ambient temperature 32°C, 70% relative humidity), 16 males aged 21.8 (1.2) years performed two trials of a work-rest cycle protocol consisting two bouts of 4-km treadmill walks with 30-kg load at 5.3km/h separated by a 15-min rest period. Ice slurry (ICE) or room temperature water (29°C) as a control (CON) was provided in 200-ml aliquots. The fluids were given 10min before the start, at the 15(th) and 30(th) min of each work cycle, and during each rest period. Spatio-temporal gait characteristics were obtained at the start and end of each work-rest cycle using a floor-based photocell system (OptoGait) and a high-speed video camera at 120Hz. Repeated-measure analysis of variance (trial×time) showed that with time, step width decreased (p=.024) while percent crossover steps increased (p=.008) from the 40(th) min onwards. Reduced stance time variability (-11.1%, p=.029) step width variability (-8.2%, p=.001), and percent crossover step (-18.5%, p=.010) were observed in ICE compared with CON. No differences in step length and most temporal variables were found. In conclusion, changes in frontal plane gait characteristics may indicate exertional heat stress during prolonged load carriage, and some of these changes may be mitigated with ice slurry ingestion. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Gender may have an influence on the relationship between Functional Movement Screen scores and gait parameters in elite junior athletes - A pilot study.

    PubMed

    Magyari, N; Szakács, V; Bartha, C; Szilágyi, B; Galamb, K; Magyar, M O; Hortobágyi, T; Kiss, R M; Tihanyi, J; Négyesi, J

    2017-09-01

    Aims The aim of this study was to examine the effects of gender on the relationship between Functional Movement Screen (FMS) and treadmill-based gait parameters. Methods Twenty elite junior athletes (10 women and 10 men) performed the FMS tests and gait analysis at a fixed speed. Between-gender differences were calculated for the relationship between FMS test scores and gait parameters, such as foot rotation, step length, and length of gait line. Results Gender did not affect the relationship between FMS and treadmill-based gait parameters. The nature of correlations between FMS test scores and gait parameters was different in women and men. Furthermore, different FMS test scores predicted different gait parameters in female and male athletes. FMS asymmetry and movement asymmetries measured by treadmill-based gait parameters did not correlate in either gender. Conclusion There were no interactions between FMS, gait parameters, and gender; however, correlation analyses support the idea that strength and conditioning coaches need to pay attention not only to how to score but also how to correctly use FMS.

  13. The effect of three different types of walking aids on spatio-temporal gait parameters in community-dwelling older adults.

    PubMed

    Härdi, Irene; Bridenbaugh, Stephanie A; Gschwind, Yves J; Kressig, Reto W

    2014-04-01

    Gait and balance impairments lead to falls and injuries in older people. Walking aids are meant to increase gait safety and prevent falls, yet little is known about how their use alters gait parameters. This study aimed to quantify gait in older adults during walking without and with different walking aids and to compare gait parameters to matched controls. This retrospective study included 65 older (≥60 years) community dwellers who used a cane, crutch or walker and 195 independently mobile-matched controls. Spatio-temporal gait parameters were measured with an electronic walkway system during normal walking. When walking unaided or aided, walking aid users had significantly worse gait than matched controls. Significant differences between the walking aid groups were found for stride time variability (cane vs. walker) in walking unaided only. Gait performances significantly improved when assessed with vs. without the walking aid for the cane (increased stride time and length, decreased cadence and stride length variability), crutch (increased stride time and length, decreased cadence, stride length variability and double support) and walker (increased gait speed and stride length, decreased base of support and double support) users. Gait in older adults who use a walking aid is more irregular and unstable than gait in independently mobile older adults. Walking aid users have better gait when using their walking aid than when walking without it. The changes in gait were different for the different types of walking aids used. These study results may help better understand gait in older adults and differentiate between pathological gait changes and compensatory gait changes due to the use of a walking aid.

  14. Gait phenotypes in paediatric hereditary spastic paraplegia revealed by dynamic time warping analysis and random forests

    PubMed Central

    Martín-Gonzalo, Juan Andrés; Rodríguez-Andonaegui, Irene; López-López, Javier; Pascual-Pascual, Samuel Ignacio

    2018-01-01

    The Hereditary Spastic Paraplegias (HSP) are a group of heterogeneous disorders with a wide spectrum of underlying neural pathology, and hence HSP patients express a variety of gait abnormalities. Classification of these phenotypes may help in monitoring disease progression and personalizing therapies. This is currently managed by measuring values of some kinematic and spatio-temporal parameters at certain moments during the gait cycle, either in the doctor´s surgery room or after very precise measurements produced by instrumental gait analysis (IGA). These methods, however, do not provide information about the whole structure of the gait cycle. Classification of the similarities among time series of IGA measured values of sagittal joint positions throughout the whole gait cycle can be achieved by hierarchical clustering analysis based on multivariate dynamic time warping (DTW). Random forests can estimate which are the most important isolated parameters to predict the classification revealed by DTW, since clinicians need to refer to them in their daily practice. We acquired time series of pelvic, hip, knee, ankle and forefoot sagittal angular positions from 26 HSP and 33 healthy children with an optokinetic IGA system. DTW revealed six gait patterns with different degrees of impairment of walking speed, cadence and gait cycle distribution and related with patient’s age, sex, GMFCS stage, concurrence of polyneuropathy and abnormal visual evoked potentials or corpus callosum. The most important parameters to differentiate patterns were mean pelvic tilt and hip flexion at initial contact. Longer time of support, decreased values of hip extension and increased knee flexion at initial contact can differentiate the mildest, near to normal HSP gait phenotype and the normal healthy one. Increased values of knee flexion at initial contact and delayed peak of knee flexion are important factors to distinguish GMFCS stages I from II-III and concurrence of polyneuropathy

  15. Age-related changes in physical examination and gait parameters in normally developing children and adolescents.

    PubMed

    Lee, Seung Yeol; Lee, Sang Hyeong; Chung, Chin Youb; Park, Moon Seok; Lee, Kyoung Min; Akhmedov, Bekhzad; Choi, In Ho; Cho, Tae-Joon; Yoo, Won Joon; Sung, Ki Hyuk

    2013-03-01

    This study aimed to examine the correlations between physical examinations and gait kinematics, and age-related changes in 47 normally developing children. Physical examinations were not found to be significantly correlated with kinematics, except for Thomas and Staheli tests. Unilateral and bilateral popliteal angles decreased significantly by 2.2 and 1.6° per annum, and ankle dorsiflexion with knee extension and 90° flexion decreased significantly by 0.7 and 0.8°. Physical examinations and gait parameters might represent different dimensions of gait, and care should be taken when assessing gait problems. Age-related changes should be considered when interpreting physical examination and gait kinematics for surgery.

  16. The impact of obesity in the kinematic parameters of gait in young women

    PubMed Central

    da Silva-Hamu, Tânia Cristina Dias; Formiga, Cibelle Kayenne Martins Roberto; Gervásio, Flávia Martins; Ribeiro, Darlan Martins; Christofoletti, Gustavo; de França Barros, Jônatas

    2013-01-01

    Background The prevalence of obesity is increasing in the population, particularly in women. Obesity has an impact on the musculoskeletal system, leading to knee and ankle overexertion, difficulty with balance, and functional disability. The aim of this study was to identify changes in kinematic parameters of gait in obese young women. Methods A case-control study with 24 obese women (mean age 35.20 ± 9.9 years and mean body mass index of 31.85 ± 2.94 kg/m2) and 24 eutrophic women (mean age of 36.33 ± 11.14 and mean body mass index of 21.82 ± 1.58 kg/m2). The gait of women was evaluated by the system Vicon Motus® 9.2. The linear parameters of speed, cadence, right and left step, and stride lengths were studied, as well as the angular parameters of knee and ankle. Results There was a decrease in linear gait parameters (P < 0.001), speed, cadence, right and left step, and stride lengths. In regard to the angular parameters of the knee and ankle, there were also differences between the analyses (P < 0.001). At the knee joint, obese women have delayed onset of the second wave of flexion, exacerbating such movement in order to compensate. In regard to the ankle, both groups showed curves of normal plantar flexion and dorsiflexion, but there was a delay in the path graph in the ankle of obese women indicating a reduced range of motion and possible over-exertion of the pretibial muscles and soleus muscles simultaneously. Conclusion The results of this study revealed that obesity is a factor that negatively influences the kinematic parameters of gait of young women. PMID:23837005

  17. Inter-trial and test–retest reliability of kinematic and kinetic gait parameters among subjects with adolescent idiopathic scoliosis

    PubMed Central

    Nadeau, Sylvie; Labelle, Hubert

    2007-01-01

    Gait analysis is actually used in subjects with scoliosis to determine the change in lower limb parameters after surgery, but the reliability of these parameters still remained unknown. The purpose of this study was to assess the repeatability of traditional gait parameters in subjects with adolescent idiopathic scoliosis (AIS) and to estimate the associated standard error of measurement (SEM). A test–retest design was used to assess the reliability of gait parameters at self-selected and fast speeds. A convenience sample of 20 girls aged from 12 to 17 years, with an idiopathic scoliosis (King classification: types I, II or III; Cobb angle 17–50°) participated in the study. Five good trials were recorded on two occasions. The time-distance, kinematic, and kinetic gait parameters were recorded using foot-switches in combination with a three-dimensional motion analysis system (Optotrak) and Advanced Mechanical Technologies Inc., (AMTI) Watertown, MA, USA; force plates. The coefficients of dependability and SEM derived from the generalizability theory were used to assess the reliability. Inter-trial reliability was good for time-distance, kinematic, and kinetic (absolute and normalized) gait parameters except for the medio-lateral ground reaction force (GRF) component and the ankle dorsiflexor moment (ϕ = 0.60–0.77). Test–retest reliability was higher for the kinetic than for the kinematic parameters. These coefficients ranged from 0.42 to 0.58 for the time-distance parameters; from 0.55 to 0.88 for the angular displacements and from 0.25 to 0.99 for the kinetic parameters. The SEMs were lower than 3.3° for the angular displacements and lower than 8 Nm (0.15 Nm/kg) and 36 W (0.54 W/Kg) for the joint moments and powers regardless of the speed. Several gait parameters are reliable among subjects with AIS and can be used to assess the evolution of the spinal modifications and the impact of treatment on their lower limb gait pattern. PMID:17891424

  18. Reliability of spatiotemporal and kinetic gait parameters determined by a new instrumented treadmill system.

    PubMed

    Reed, Lloyd F; Urry, Stephen R; Wearing, Scott C

    2013-08-21

    Despite the emerging use of treadmills integrated with pressure platforms as outcome tools in both clinical and research settings, published evidence regarding the measurement properties of these new systems is limited. This study evaluated the within- and between-day repeatability of spatial, temporal and vertical ground reaction force parameters measured by a treadmill system instrumented with a capacitance-based pressure platform. Thirty three healthy adults (mean age, 21.5 ± 2.8 years; height, 168.4 ± 9.9 cm; and mass, 67.8 ± 18.6 kg), walked barefoot on a treadmill system (FDM-THM-S, Zebris Medical GmbH) on three separate occasions. For each testing session, participants set their preferred pace but were blinded to treadmill speed. Spatial (foot rotation, step width, stride and step length), temporal (stride and step times, duration of stance, swing and single and double support) and peak vertical ground reaction force variables were collected over a 30-second capture period, equating to an average of 52 ± 5 steps of steady-state walking. Testing was repeated one week following the initial trial and again, for a third time, 20 minutes later. Repeated measures ANOVAs within a generalized linear modelling framework were used to assess between-session differences in gait parameters. Agreement between gait parameters measured within the same day (session 2 and 3) and between days (session 1 and 2; 1 and 3) were evaluated using the 95% repeatability coefficient. There were statistically significant differences in the majority (14/16) of temporal, spatial and kinetic gait parameters over the three test sessions (P < .01). The minimum change that could be detected with 95% confidence ranged between 3% and 17% for temporal parameters, 14% and 33% for spatial parameters, and 4% and 20% for kinetic parameters between days. Within-day repeatability was similar to that observed between days. Temporal and kinetic gait parameters were typically more

  19. Analysis of several methods and inertial sensors locations to assess gait parameters in able-bodied subjects.

    PubMed

    Ben Mansour, Khaireddine; Rezzoug, Nasser; Gorce, Philippe

    2015-10-01

    The purpose of this paper was to determine which types of inertial sensors and which advocated locations should be used for reliable and accurate gait event detection and temporal parameter assessment in normal adults. In addition, we aimed to remove the ambiguity found in the literature of the definition of the initial contact (IC) from the lumbar accelerometer. Acceleration and angular velocity data was gathered from the lumbar region and the distal edge of each shank. This data was evaluated in comparison to an instrumented treadmill and an optoelectronic system during five treadmill speed sessions. The lumbar accelerometer showed that the peak of the anteroposterior component was the most accurate for IC detection. Similarly, the valley that followed the peak of the vertical component was the most precise for terminal contact (TC) detection. Results based on ANOVA and Tukey tests showed that the set of inertial methods was suitable for temporal gait assessment and gait event detection in able-bodied subjects. For gait event detection, an exception was found with the shank accelerometer. The tool was suitable for temporal parameters assessment, despite the high root mean square error on the detection of IC (RMSEIC) and TC (RMSETC). The shank gyroscope was found to be as accurate as the kinematic method since the statistical tests revealed no significant difference between the two techniques for the RMSE off all gait events and temporal parameters. The lumbar and shank accelerometers were the most accurate alternative to the shank gyroscope for gait event detection and temporal parameters assessment, respectively. Copyright © 2015. Published by Elsevier B.V.

  20. Estimation of spatial-temporal gait parameters using a low-cost ultrasonic motion analysis system.

    PubMed

    Qi, Yongbin; Soh, Cheong Boon; Gunawan, Erry; Low, Kay-Soon; Thomas, Rijil

    2014-08-20

    In this paper, a low-cost motion analysis system using a wireless ultrasonic sensor network is proposed and investigated. A methodology has been developed to extract spatial-temporal gait parameters including stride length, stride duration, stride velocity, stride cadence, and stride symmetry from 3D foot displacements estimated by the combination of spherical positioning technique and unscented Kalman filter. The performance of this system is validated against a camera-based system in the laboratory with 10 healthy volunteers. Numerical results show the feasibility of the proposed system with average error of 2.7% for all the estimated gait parameters. The influence of walking speed on the measurement accuracy of proposed system is also evaluated. Statistical analysis demonstrates its capability of being used as a gait assessment tool for some medical applications.

  1. Clinical Gait Evaluation of Patients with Lumbar Spine Stenosis.

    PubMed

    Sun, Jun; Liu, Yan-Cheng; Yan, Song-Hua; Wang, Sha-Sha; Lester, D Kevin; Zeng, Ji-Zhou; Miao, Jun; Zhang, Kuan

    2018-02-01

    The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3, MiniSun, CA) has been developed for clinical gait evaluation, and this study was designed to evaluate the accuracy and reliability of IDEEA3 for the gait measurement of lumbar spinal stenosis (LSS) patients. Twelve healthy volunteers were recruited to compare gait cycle, cadence, step length, velocity, and number of steps between a motion analysis system and a high-speed video camera. Twenty hospitalized LSS patients were recruited for the comparison of the five parameters between the IDEEA3 and GoPro camera. Paired t-test, intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plots were used for the data analysis. The ratios of GoPro camera results to motion analysis system results, and the ratios of IDEEA3 results to GoPro camera results were all around 1.00. All P-values of paired t-tests for gait cycle, cadence, step length, and velocity were greater than 0.05, while all the ICC and CCC results were above 0.950 with P < 0.001. The measurements for gait cycle, cadence, step length, velocity, and number of steps with the GoPro camera are highly consistent with the measurements with the motion analysis system. The measurements for IDEEA3 are consistent with those for the GoPro camera. IDEEA3 can be effectively used in the gait measurement of LSS patients. © 2018 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  2. Analysis of gait symmetry during over-ground walking in children with autism spectrum disorder.

    PubMed

    Eggleston, Jeffrey D; Harry, John R; Hickman, Robbin A; Dufek, Janet S

    2017-06-01

    Gait symmetry is utilized as an indicator of neurologic function. Healthy gait often exhibits minimal asymmetries, while pathological gait exhibits exaggerated asymmetries. The purpose of this study was to examine symmetry of mechanical gait parameters during over-ground walking in children with Autism Spectrum Disorder (ASD). Kinematic and kinetic data were obtained from 10 children (aged 5-12 years) with ASD. The Model Statistic procedure (α=0.05) was used to compare gait related parameters between limbs. Analysis revealed children with ASD exhibit significant lower extremity joint position and ground reaction force asymmetries throughout the gait cycle. The observed asymmetries were unique for each subject. These data do not support previous research relative to gait symmetry in children with ASD. Many individuals with ASD do not receive physical therapy interventions, however, precision medicine based interventions emphasizing lower extremity asymmetries may improve gait function and improve performance during activities of daily living. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Do spatiotemporal parameters and gait variability differ across the lifespan of healthy adults? A systematic review.

    PubMed

    Herssens, Nolan; Verbecque, Evi; Hallemans, Ann; Vereeck, Luc; Van Rompaey, Vincent; Saeys, Wim

    2018-06-12

    Aging is often associated with changes in the musculoskeletal system, peripheral and central nervous system. These age-related changes often result in mobility problems influencing gait performance. Compensatory strategies are used as a way to adapt to these physiological changes. The aim of this review is to investigate the differences in spatiotemporal and gait variability measures throughout the healthy adult life. This systematic review was conducted according to the PRISMA guidelines and registered in the PROSPERO database (no. CRD42017057720). Databases MEDLINE (Pubmed), Web of Science (Web of Knowledge), Cochrane Library and ScienceDirect were systematically searched until March 2018. Eighteen of the 3195 original studies met the eligibility criteria and were included in this review. The majority of studies reported spatiotemporal and gait variability measures in adults above the age of 65, followed by the young adult population, information of middle-aged adults is lacking. Spatiotemporal parameters and gait variability measures were extracted from 2112 healthy adults between 18 and 98 years old and, in general, tend to deteriorate with increasing age. Variability measures were only reported in an elderly population and show great variety between studies. The findings of this review suggest that most spatiotemporal parameters significantly differ across different age groups. Elderly populations show a reduction of preferred walking speed, cadence, step and stride length, all related to a more cautious gait, while gait variability measures remain stable over time. A preliminary framework of normative reference data is provided, enabling insights into the influence of aging on spatiotemporal parameters, however spatiotemporal parameters of middle-aged adults should be investigated more thoroughly. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Comparison of biomechanical gait parameters of young children with haemophilia and those of age-matched peers.

    PubMed

    Stephensen, D; Drechsler, W; Winter, M; Scott, O

    2009-03-01

    Quality of life for children with haemophilia has improved since the introduction of prophylaxis. The frequency of joint haemorrhages has reduced, but the consequences of reduced bleeding on the biomechanical parameters of walking are not well understood. This study explored the differences in sagittal plane biomechanics of walking between a control group (Group 1) of normal age-matched children and children with haemophilia (Group 2) with a target ankle joint. A motion capture system and two force platforms were used to collect sagittal plane kinematic, kinetic and temporal-spatial data during walking of 14 age-matched normal children and 14 children with haemophilia aged 7-13 years. Group differences in maximum and minimum flexion/extension angles and moments of the hip, knee and ankle joints, ground reaction forces and temporal-spatial gait cycle parameters were analysed using one-way anova. Significant changes (P < 0.05) in kinematic and kinetic parameters but not temporal-spatial parameters were found in children with haemophilia; greater flexion angles and external moments of force at the knee, greater ankle plantarflexion external moments and lower hip flexion external moments. These results suggest that early biomechanical changes are present in young haemophilic children with a history of a target ankle joint and imply that lower limb joint function is more impaired than current clinical evaluations indicate. Protocols and quantitative data on the biomechanical gait pattern of children with haemophilia reported in this study provide a baseline to evaluate lower limb joint function and clinical progression.

  5. A mechanized gait trainer for restoration of gait.

    PubMed

    Hesse, S; Uhlenbrock, D

    2000-01-01

    The newly developed gait trainer allows wheel-chair-bound subjects the repetitive practice of a gait-like movement without overstressing therapists. The device simulates the phases of gait, supports the subjects according to their abilities, and controls the center of mass (CoM) in the vertical and horizontal directions. The patterns of sagittal lower limb joint kinematics and of muscle activation for a normal subject were similar when using the mechanized trainer and when walking on a treadmill. A non-ambulatory hemiparetic subject required little help from one therapist on the gait trainer, while two therapists were required to support treadmill walking. Gait movements on the trainer were highly symmetrical, impact free, and less spastic. The vertical displacement of the CoM was bi-phasic instead of mono-phasic during each gait cycle on the new device. Two cases of non-ambulatory patients, who regained their walking ability after 4 weeks of daily training on the gait trainer, are reported.

  6. Monitoring walking and cycling of middle-aged to older community dwellers using wireless wearable accelerometers.

    PubMed

    Zhang, Yuting; Beenakker, Karel G M; Butala, Pankil M; Lin, Cheng-Chieh; Little, Thomas D C; Maier, Andrea B; Stijntjes, Marjon; Vartanian, Richard; Wagenaar, Robert C

    2012-01-01

    Changes in gait parameters have been shown to be an important indicator of several age-related cognitive and physical declines of older adults. In this paper we propose a method to monitor and analyze walking and cycling activities based on a triaxial accelerometer worn on one ankle. We use an algorithm that can (1) distinguish between static and dynamic functional activities, (2) detect walking and cycling events, (3) identify gait parameters, including step frequency, number of steps, number of walking periods, and total walking duration per day, and (4) evaluate cycling parameters, including cycling frequency, number of cycling periods, and total cycling duration. Our algorithm is evaluated against the triaxial accelerometer data obtained from a group of 297 middle-aged to older adults wearing an activity monitor on the right ankle for approximately one week while performing unconstrained daily activities in the home and community setting. The correlation coefficients between each of detected gait and cycling parameters on two weekdays are all statistically significant, ranging from 0.668 to 0.873. These results demonstrate good test-retest reliability of our method in monitoring walking and cycling activities and analyzing gait and cycling parameters. This algorithm is efficient and causal in time and thus implementable for real-time monitoring and feedback.

  7. Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle

    NASA Astrophysics Data System (ADS)

    Ibrahim, I. W.; Razak, A. H. A.; Ahmad, A.; Salleh, M. K. M.

    2015-11-01

    Intra-body communication (IBC) is a communication system that uses human body as a signal transmission medium. From previous research, two coupling methods of IBC were concluded which are capacitive coupling and galvanic coupling. This paper investigates the effect of human movement on IBC using the galvanic coupling method. Because the human movement is control by the limb joint, the knee flexion angle during gait cycle was used to examine the influence of human movement on galvanic coupling IBC. The gait cycle is a cycle of people walking that start from one foot touch the ground till that foot touch the ground again. Frequency range from 300 kHz to 200MHz was swept in order to investigate the signal transmission loss and the result was focused on operating frequency 70MHz to 90MHz. Results show that the transmission loss varies when the knee flexion angle increased. The highest loss of signal at frequency range between 70MHz to 90 MHz was 69dB when the knee flexion angle is 50° and the minimum loss was 51dB during the flexion angle is 5°.

  8. Instrumented gait analysis: a measure of gait improvement by a wheeled walker in hospitalized geriatric patients.

    PubMed

    Schülein, Samuel; Barth, Jens; Rampp, Alexander; Rupprecht, Roland; Eskofier, Björn M; Winkler, Jürgen; Gaßmann, Karl-Günter; Klucken, Jochen

    2017-02-27

    In an increasing aging society, reduced mobility is one of the most important factors limiting activities of daily living and overall quality of life. The ability to walk independently contributes to the mobility, but is increasingly restricted by numerous diseases that impair gait and balance. The aim of this cross-sectional observation study was to examine whether spatio-temporal gait parameters derived from mobile instrumented gait analysis can be used to measure the gait stabilizing effects of a wheeled walker (WW) and whether these gait parameters may serve as surrogate marker in hospitalized patients with multifactorial gait and balance impairment. One hundred six patients (ages 68-95) wearing inertial sensor equipped shoes passed an instrumented walkway with and without gait support from a WW. The walkway assessed the risk of falling associated gait parameters velocity, swing time, stride length, stride time- and double support time variability. Inertial sensor-equipped shoes measured heel strike and toe off angles, and foot clearance. The use of a WW improved the risk of spatio-temporal parameters velocity, swing time, stride length and the sagittal plane associated parameters heel strike and toe off angles in all patients. First-time users (FTUs) showed similar gait parameter improvement patterns as frequent WW users (FUs). However, FUs with higher levels of gait impairment improved more in velocity, stride length and toe off angle compared to the FTUs. The impact of a WW can be quantified objectively by instrumented gait assessment. Thus, objective gait parameters may serve as surrogate markers for the use of walking aids in patients with gait and balance impairments.

  9. Anti-Dementia Drugs, Gait Performance and Mental Imagery of Gait: A Non-Randomized Open-Label Trial.

    PubMed

    Beauchet, Olivier; Barden, John; Liu-Ambrose, Teresa; Chester, Victoria L; Annweiler, Cedric; Szturm, Tony; Grenier, Sébastien; Léonard, Guillaume; Bherer, Louis; Allali, Gilles

    2016-09-01

    Few studies have examined the effect of anti-dementia drugs (i.e., acetylcholinesterase inhibitors and N-methyl-D-aspartate receptor antagonists) on gait performance. Past studies have focused on the stride time (i.e., gait cycle duration) but not on the mental imagery of gait. To compare mental imagery of gait and spatiotemporal gait parameters in patients with dementia [i.e., Alzheimer's disease (AD) and non-AD] before and after the use of anti-dementia drugs (i.e., acetylcholinesterase inhibitors and memantine) and in controls (i.e., patients with dementia who did not take anti-dementia drugs). A total of 112 patients (mean age 82.5 ± 4.2 years, 68.8 % female) with mild-to-moderate AD and non-AD dementia were included in this non-randomized open-label trial (n = 56 in the Intervention group, and n = 56 in the Control group matched for age, sex, and stage and type of dementia) nested in a cohort study (mean follow-up 238.5 ± 79.8 days). Mental imagery of gait was assessed with the actual and imagined Timed Up and Go tests (aTUG and iTUG) and the difference between aTUG and iTUG (i.e., delta-TUG). Spatiotemporal gait parameters were measured with the GAITRite(®) system during normal walking. Participants in the Intervention group had a longer iTUG time (p < 0.001) and a lower delta-TUG value (p = 0.001) at the follow-up compared with those in the Control group. There was a significant increase in iTUG (p = 0.001) and decrease in delta-TUG (p < 0.001) from baseline to the follow-up only in the Intervention group. Multiple linear regression showed that the use of anti-dementia drugs was associated with a longer iTUG time and a lower delta-TUG value (best performance, p < 0.002). Our findings showed an improvement in mental imagery of gait with the use of anti-dementia drugs, but no changes in actual gait performance. NCT01315704.

  10. Total hip arthroplasty using a cementless dual-mobility cup provides increased stability and favorable gait parameters at five years follow-up.

    PubMed

    Acker, A; Fischer, J-F; Aminian, K; Lécureux, E; Jolles, B M

    2017-02-01

    Rates of dislocation following primary total hip arthroplasty (THA) vary from 0.5 to 10%. Dual-mobility cups in THA demonstrate increased stability. Clinical outcomes following THA with dual-mobility cups have been reported, but gait has not been assessed. Therefore we performed a retrospective case control study to answer: (1) is gait better in patients following THA with a dual-mobility cup than in frail, elderly patients of the same age? (2) Are clinical outcomes better in patients following THA with a dual-mobility cup than in frail, elderly patients? (3) What is the dislocation rate following THA with a dual-mobility cup? We hypothesized that patients who underwent THA with a dual-mobility cup have a better gait compared to frail, elderly patients of the same age. Twenty patients (22 hips), mean age 79.9±7.7 (range, 62.3-88.3) years were assessed in this retrospective case-control series 5.6±1.4 (range: 4.1-8.8) years following dual-mobility cup THA. A reference group consisted of 72 "frail elderly" patients in a rehabilitation hospital for health problems unrelated to the lower limb, with no lower limb surgery or neurological conditions. Temporal and spatial gait performance were measured with four miniature gyroscopes, mounted on each thigh and calf, while patients walked freely along a 30m corridor. Harris Hip Score, WOMAC, radiological outcomes, and dislocation rate were determined. All gait parameters were better in the dual-mobility group compared to the frail elderly group. The dual-mobility group had a higher cadence (100.3 steps/minute versus 75.6 steps/minute), shorter (relative to gait cycle time) stance (61.6% versus 67.8%), shorter (relative to gait cycle time) double stance (23.3% versus 36.0%), longer stride (1.13m versus 0.80m), and faster walking speed (0.96m/s versus 0.52m/s). Range of motion of the shank, thigh and knee were better in the dual-mobility group. Harris Hip Score was 87.6±13.9 (range 51-100) and WOMAC score was 11.3±12

  11. Multilayer Joint Gait-Pose Manifolds for Human Gait Motion Modeling.

    PubMed

    Ding, Meng; Fan, Guolian

    2015-11-01

    We present new multilayer joint gait-pose manifolds (multilayer JGPMs) for complex human gait motion modeling, where three latent variables are defined jointly in a low-dimensional manifold to represent a variety of body configurations. Specifically, the pose variable (along the pose manifold) denotes a specific stage in a walking cycle; the gait variable (along the gait manifold) represents different walking styles; and the linear scale variable characterizes the maximum stride in a walking cycle. We discuss two kinds of topological priors for coupling the pose and gait manifolds, i.e., cylindrical and toroidal, to examine their effectiveness and suitability for motion modeling. We resort to a topologically-constrained Gaussian process (GP) latent variable model to learn the multilayer JGPMs where two new techniques are introduced to facilitate model learning under limited training data. First is training data diversification that creates a set of simulated motion data with different strides. Second is the topology-aware local learning to speed up model learning by taking advantage of the local topological structure. The experimental results on the Carnegie Mellon University motion capture data demonstrate the advantages of our proposed multilayer models over several existing GP-based motion models in terms of the overall performance of human gait motion modeling.

  12. Quantification of gait parameters in freely walking wild type and sensory deprived Drosophila melanogaster

    PubMed Central

    Mendes, César S; Bartos, Imre; Akay, Turgay; Márka, Szabolcs; Mann, Richard S

    2013-01-01

    Coordinated walking in vertebrates and multi-legged invertebrates such as Drosophila melanogaster requires a complex neural network coupled to sensory feedback. An understanding of this network will benefit from systems such as Drosophila that have the ability to genetically manipulate neural activities. However, the fly's small size makes it challenging to analyze walking in this system. In order to overcome this limitation, we developed an optical method coupled with high-speed imaging that allows the tracking and quantification of gait parameters in freely walking flies with high temporal and spatial resolution. Using this method, we present a comprehensive description of many locomotion parameters, such as gait, tarsal positioning, and intersegmental and left-right coordination for wild type fruit flies. Surprisingly, we find that inactivation of sensory neurons in the fly's legs, to block proprioceptive feedback, led to deficient step precision, but interleg coordination and the ability to execute a tripod gait were unaffected. DOI: http://dx.doi.org/10.7554/eLife.00231.001 PMID:23326642

  13. Changes in frontal plane dynamics and the loading response phase of the gait cycle are characteristic of severe knee osteoarthritis application of a multidimensional analysis technique.

    PubMed

    Astephen, J L; Deluzio, K J

    2005-02-01

    Osteoarthritis of the knee is related to many correlated mechanical factors that can be measured with gait analysis. Gait analysis results in large data sets. The analysis of these data is difficult due to the correlated, multidimensional nature of the measures. A multidimensional model that uses two multivariate statistical techniques, principal component analysis and discriminant analysis, was used to discriminate between the gait patterns of the normal subject group and the osteoarthritis subject group. Nine time varying gait measures and eight discrete measures were included in the analysis. All interrelationships between and within the measures were retained in the analysis. The multidimensional analysis technique successfully separated the gait patterns of normal and knee osteoarthritis subjects with a misclassification error rate of <6%. The most discriminatory feature described a static and dynamic alignment factor. The second most discriminatory feature described a gait pattern change during the loading response phase of the gait cycle. The interrelationships between gait measures and between the time instants of the gait cycle can provide insight into the mechanical mechanisms of pathologies such as knee osteoarthritis. These results suggest that changes in frontal plane loading and alignment and the loading response phase of the gait cycle are characteristic of severe knee osteoarthritis gait patterns. Subsequent investigations earlier in the disease process may suggest the importance of these factors to the progression of knee osteoarthritis.

  14. A Mobile Kalman-Filter Based Solution for the Real-Time Estimation of Spatio-Temporal Gait Parameters.

    PubMed

    Ferrari, Alberto; Ginis, Pieter; Hardegger, Michael; Casamassima, Filippo; Rocchi, Laura; Chiari, Lorenzo

    2016-07-01

    Gait impairments are among the most disabling symptoms in several musculoskeletal and neurological conditions, severely limiting personal autonomy. Wearable gait sensors have been attracting attention as diagnostic tool for gait and are emerging as promising tool for tutoring and guiding gait execution. If their popularity is continuously growing, still there is room for improvement, especially towards more accurate solutions for spatio-temporal gait parameters estimation. We present an implementation of a zero-velocity-update gait analysis system based on a Kalman filter and off-the-shelf shoe-worn inertial sensors. The algorithms for gait events and step length estimation were specifically designed to comply with pathological gait patterns. More so, an Android app was deployed to support fully wearable and stand-alone real-time gait analysis. Twelve healthy subjects were enrolled to preliminarily tune the algorithms; afterwards sixteen persons with Parkinson's disease were enrolled for a validation study. Over the 1314 strides collected on patients at three different speeds, the total root mean square difference on step length estimation between this system and a gold standard was 2.9%. This shows that the proposed method allows for an accurate gait analysis and paves the way to a new generation of mobile devices usable anywhere for monitoring and intervention.

  15. Treadmill locomotion of the mouse lemur (Microcebus murinus); kinematic parameters during symmetrical and asymmetrical gaits.

    PubMed

    Herbin, Marc; Hommet, Eva; Hanotin-Dossot, Vicky; Perret, Martine; Hackert, Rémi

    2018-06-01

    The gaits of the adult grey mouse lemur Microcebus murinus were studied during treadmill locomotion over a large range of velocities. The locomotion sequences were analysed to determine the gait and the various spatiotemporal gait parameters of the limbs. We found that velocity adjustments are accounted for differently by stride frequency and stride length depending on whether the animal showed a symmetrical or an asymmetrical gait. When using symmetrical gaits the increase in velocity is associated with a constant contribution of the stride length and stride frequency; the increase of the stride frequency being always lower. When using asymmetrical gaits, the increase in velocity is mainly assured by an increase in the stride length which tends to decrease with increasing velocity. A reduction in both stance time and swing time contributed to the increase in stride frequency for both gaits, though with a major contribution from the decrease in stance time. The pattern of locomotion obtained in a normal young adult mouse lemurs can be used as a template for studying locomotor control deficits during aging or in different environments such as arboreal ones which likely modify the kinematics of locomotion.

  16. Gait and Cognition in Parkinson's Disease: Cognitive Impairment Is Inadequately Reflected by Gait Performance during Dual Task.

    PubMed

    Gaßner, Heiko; Marxreiter, Franz; Steib, Simon; Kohl, Zacharias; Schlachetzki, Johannes C M; Adler, Werner; Eskofier, Bjoern M; Pfeifer, Klaus; Winkler, Jürgen; Klucken, Jochen

    2017-01-01

    Cognitive and gait deficits are common symptoms in Parkinson's disease (PD). Motor-cognitive dual tasks (DTs) are used to explore the interplay between gait and cognition. However, it is unclear if DT gait performance is indicative for cognitive impairment. Therefore, the aim of this study was to investigate if cognitive deficits are reflected by DT costs of spatiotemporal gait parameters. Cognitive function, single task (ST) and DT gait performance were investigated in 67 PD patients. Cognition was assessed by the Montreal Cognitive Assessment (MoCA) followed by a standardized, sensor-based gait test and the identical gait test while subtracting serial 3's. Cognitive impairment was defined by a MoCA score <26. DT costs in gait parameters [(DT - ST)/ST × 100] were calculated as a measure of DT effect on gait. Correlation analysis was used to evaluate the association between MoCA performance and gait parameters. In a linear regression model, DT gait costs and clinical confounders (age, gender, disease duration, motor impairment, medication, and depression) were correlated to cognitive performance. In a subgroup analysis, we compared matched groups of cognitively impaired and unimpaired PD patients regarding differences in ST, DT, and DT gait costs. Correlation analysis revealed weak correlations between MoCA score and DT costs of gait parameters ( r / r Sp  ≤ 0.3). DT costs of stride length, swing time variability, and maximum toe clearance (| r / r Sp | > 0.2) were included in a regression analysis. The parameters only explain 8% of the cognitive variance. In combination with clinical confounders, regression analysis showed that these gait parameters explained 30% of MoCA performance. Group comparison revealed strong DT effects within both groups (large effect sizes), but significant between-group effects in DT gait costs were not observed. These findings suggest that DT gait performance is not indicative for cognitive impairment in PD. DT

  17. Gait parameter risk factors for falls under simple and dual task conditions in cognitively impaired older people.

    PubMed

    Taylor, Morag E; Delbaere, Kim; Mikolaizak, A Stefanie; Lord, Stephen R; Close, Jacqueline C T

    2013-01-01

    Impaired gait may contribute to the increased rate of falls in cognitively impaired older people. We investigated whether gait under simple and dual task conditions could predict falls in this group. The study sample consisted of 64 community dwelling older people with mild to moderate cognitive impairment. Participants walked at their preferred speed under three conditions: (a) simple walking, (b) walking while carrying a glass of water and (c) walking while counting backwards from 30. Spatiotemporal gait parameters were measured using the GAITRite(®) mat. Falls were recorded prospectively for 12months with the assistance of carers. Twenty-two (35%) people fell two or more times in the 12month follow-up period. There was a significant main effect of gait condition and a significant main effect of faller status for mean value measures (velocity, stride length, double support time and stride width) and for variability measures (swing time variability and stride length variability). Examination of individual gait parameters indicated that the multiple fallers walked more slowly, had shorter stride length, spent longer time in double support, had a wider support width and showed more variability in stride length and swing time (p<0.05). There was no significant interaction between gait condition and faller status for any of the gait variables. In conclusion, dual task activities adversely affect gait in cognitively impaired older people. Multiple fallers performed worse in each gait condition but the addition of a functional or cognitive secondary task provided no added benefit in discriminating fallers from non-fallers with cognitive impairment. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Automated classification of neurological disorders of gait using spatio-temporal gait parameters.

    PubMed

    Pradhan, Cauchy; Wuehr, Max; Akrami, Farhoud; Neuhaeusser, Maximilian; Huth, Sabrina; Brandt, Thomas; Jahn, Klaus; Schniepp, Roman

    2015-04-01

    Automated pattern recognition systems have been used for accurate identification of neurological conditions as well as the evaluation of the treatment outcomes. This study aims to determine the accuracy of diagnoses of (oto-)neurological gait disorders using different types of automated pattern recognition techniques. Clinically confirmed cases of phobic postural vertigo (N = 30), cerebellar ataxia (N = 30), progressive supranuclear palsy (N = 30), bilateral vestibulopathy (N = 30), as well as healthy subjects (N = 30) were recruited for the study. 8 measurements with 136 variables using a GAITRite(®) sensor carpet were obtained from each subject. Subjects were randomly divided into two groups (training cases and validation cases). Sensitivity and specificity of k-nearest neighbor (KNN), naive-bayes classifier (NB), artificial neural network (ANN), and support vector machine (SVM) in classifying the validation cases were calculated. ANN and SVM had the highest overall sensitivity with 90.6% and 92.0% respectively, followed by NB (76.0%) and KNN (73.3%). SVM and ANN showed high false negative rates for bilateral vestibulopathy cases (20.0% and 26.0%); while KNN and NB had high false negative rates for progressive supranuclear palsy cases (76.7% and 40.0%). Automated pattern recognition systems are able to identify pathological gait patterns and establish clinical diagnosis with good accuracy. SVM and ANN in particular differentiate gait patterns of several distinct oto-neurological disorders of gait with high sensitivity and specificity compared to KNN and NB. Both SVM and ANN appear to be a reliable diagnostic and management tool for disorders of gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. A Wearable Magneto-Inertial System for Gait Analysis (H-Gait): Validation on Normal Weight and Overweight/Obese Young Healthy Adults

    PubMed Central

    Gastaldi, Laura; Rosso, Valeria; Knaflitz, Marco; Tadano, Shigeru

    2017-01-01

    Background: Wearable magneto-inertial sensors are being increasingly used to obtain human motion measurements out of the lab, although their performance in applications requiring high accuracy, such as gait analysis, are still a subject of debate. The aim of this work was to validate a gait analysis system (H-Gait) based on magneto-inertial sensors, both in normal weight (NW) and overweight/obese (OW) subjects. The validation is performed against a reference multichannel recording system (STEP32), providing direct measurements of gait timings (through foot-switches) and joint angles in the sagittal plane (through electrogoniometers). Methods: Twenty-two young male subjects were recruited for the study (12 NW, 10 OW). After positioning body-fixed sensors of both systems, each subject was asked to walk, at a self-selected speed, over a 14-m straight path for 12 trials. Gait signals were recorded, at the same time, with the two systems. Spatio-temporal parameters, ankle, knee, and hip joint kinematics were extracted analyzing an average of 89 ± 13 gait cycles from each lower limb. Intraclass correlation coefficient and Bland-Altmann plots were used to compare H-Gait and STEP32 measurements. Changes in gait parameters and joint kinematics of OW with respect NW were also evaluated. Results: The two systems were highly consistent for cadence, while a lower agreement was found for the other spatio-temporal parameters. Ankle and knee joint kinematics is overall comparable. Joint ROMs values were slightly lower for H-Gait with respect to STEP32 for the ankle (by 1.9° for NW, and 1.6° for OW) and for the knee (by 4.1° for NW, and 1.8° for OW). More evident differences were found for hip joint, with ROMs values higher for H-Gait (by 6.8° for NW, and 9.5° for OW). NW and OW showed significant differences considering STEP32 (p = 0.0004), but not H-Gait (p = 0.06). In particular, overweight/obese subjects showed a higher cadence (55.0 vs. 52.3 strides/min) and a lower hip

  20. Effect of total knee replacement surgery and postoperative 12 month home exercise program on gait parameters.

    PubMed

    Heikkilä, A; Sevander-Kreus, N; Häkkinen, A; Vuorenmaa, M; Salo, Petr; Konsta, P; Ylinen, J

    2017-03-01

    To evaluate the effects of surgery and a postoperative progressive home exercise program on gait parameters among individuals operated with total knee arthroplasty. Single blinded randomized controlled trial. 108 patients (84 females, 24 males, mean age 69 years). Patients were equally randomized into an exercise group (EG) and control group (CG). The 12-months progressive home exercise program starting two months postoperatively was compared to usual care. Gait analysis was performed using the Gaitrite electronic walkway system. In addition, knee extension and flexion strength were measured by a dynamometer preoperatively, and pain on visual analog scale (VAS) at two months and 14 months postoperatively. At the 12-month follow-up, maximal gait velocity (p=0.006), cadence (p=0.003) and stance time (p=0.039) showed a greater increase among EG than CG. All the other gait parameters improved among both groups, but with not statistically discernible difference between groups. Weak correlations were found between changes in maximal gait velocity and the knee extension (r=-0.31, p=0.002), flexion strength (r=0.28, p=0.004) and pain during loading (r=-0.27, p=0.005) values. The intervention produced statistically significant changes in maximal gait velocity, cadence and stance times in the exercise group compared to controls. Although the average change was small it is of importance that biggest changes occurred in those with low performance. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Implementation of a gait cycle loading into healthy and meniscectomised knee joint models with fibril-reinforced articular cartilage.

    PubMed

    Mononen, Mika E; Jurvelin, Jukka S; Korhonen, Rami K

    2015-01-01

    Computational models can be used to evaluate the functional properties of knee joints and possible risk locations within joints. Current models with fibril-reinforced cartilage layers do not provide information about realistic human movement during walking. This study aimed to evaluate stresses and strains within a knee joint by implementing load data from a gait cycle in healthy and meniscectomised knee joint models with fibril-reinforced cartilages. A 3D finite element model of a knee joint with cartilages and menisci was created from magnetic resonance images. The gait cycle data from varying joint rotations, translations and axial forces were taken from experimental studies and implemented into the model. Cartilage layers were modelled as a fibril-reinforced poroviscoelastic material with the menisci considered as a transversely isotropic elastic material. In the normal knee joint model, relatively high maximum principal stresses were specifically predicted to occur in the medial condyle of the knee joint during the loading response. Bilateral meniscectomy increased stresses, strains and fluid pressures in cartilage on the lateral side, especially during the first 50% of the stance phase of the gait cycle. During the entire stance phase, the superficial collagen fibrils modulated stresses of cartilage, especially in the medial tibial cartilage. The present computational model with a gait cycle and fibril-reinforced biphasic cartilage revealed time- and location-dependent differences in stresses, strains and fluid pressures occurring in cartilage during walking. The lateral meniscus was observed to have a more significant role in distributing loads across the knee joint than the medial meniscus, suggesting that meniscectomy might initiate a post-traumatic process leading to osteoarthritis at the lateral compartment of the knee joint.

  2. Does positive pressure body weight-support alter spatiotemporal gait parameters in healthy and parkinsonian individuals?

    PubMed

    Lander, Joshua J; Moran, Matthew F

    2017-01-01

    Evidence suggests treadmill training (TT) and body weight-supported treadmill training (BWSTT) are effective strategies to improve gait in Parkinson's disease (PD) patients. However, few researchers have investigated the spatiotemporal parameters during TT or BWSTT. The goal of this study is to determine gait adaptations in PD and healthy subjects during positive pressure BWSTT and post-intervention overground walking. Ten PD and ten healthy individuals participated in this study. Baseline spatiotemporal parameters were assessed using a six meter instrumented mat. A 10-min progressive BWSTT trial from 10% to 40% body weight support (BWS) was then completed. Video capture and analysis of 10-min BWSTT trials were performed to determine spatiotemporal gait parameters. Three (5-min, 10-min, and 15-min) post-intervention overground assessments were obtained. During positive pressure BWSTT there was a significant effect of BW support on step length(SL) increase (p < 0.01) and cadence decrease (p < 0.001) in the healthy group but not in the PD group (p = 0.45 SL, p = 0.21 cadence). In post-intervention assessments there was a significant effect of time on velocity (p < 0.002 non-PD, p < 0.001 PD) and cadence (p < 0.05 non-PD, p < 0.01 PD) in both groups. There appears to be a generalized effect of TT on overground gait mechanics after a single session of positive pressure BWSTT regardless of PD impairment.

  3. Gait outcome following outpatient physiotherapy based on the Bobath concept in people post stroke.

    PubMed

    Lennon, Sheila; Ashburn, Ann; Baxter, David

    The purpose of this study was to characterize the gait cycle of patients with hemiplegia before and after a period of outpatient physiotherapy based on the Bobath concept. Nine patients, at least 6 weeks post stroke and recently discharged from a stroke unit, were measured before and after a period of outpatient physiotherapy (mean duration = 17.4 weeks). Therapy was documented using a treatment checklist for each patient. The primary outcome measures were a number of gait variables related to the therapists' treatment hypothesis, recorded during the gait cycle using the CODA motion analysis system. Other secondary outcome measures were the Motor Assessment Scale, Modified Ashworth Scale, subtests of the Sodring Motor Evaluation Scale, the Step test, a 10-m walk test, the Barthel Index and the London Handicap Score. Recovery of more normal gait patterns in the gait cycle (using motion analysis) did not occur. Significant changes in temporal parameters (loading response, single support time) for both legs, in one kinematic (dorsiflexion during stance) and one kinetic variable on the unaffected side (hip flexor moment), and most of the clinical measures of impairment, activity and participation (with the exception of the Modified Ashworth Scale and the 10-m walk) were noted. Study findings did not support the hypothesis that the Bobath approach restored more normal movement patterns to the gait cycle. Further research is required to investigate the treatment techniques that are effective at improving walking ability in people after stroke.

  4. Exploring the feasibility and acceptability of sensor monitoring of gait and falls in the homes of persons with multiple sclerosis.

    PubMed

    Newland, Pamela; Wagner, Joanne M; Salter, Amber; Thomas, Florian P; Skubic, Marjorie; Rantz, Marilyn

    2016-09-01

    Gait parameters variability and falls are problems for persons with MS and have not been adequately captured in the home. Our goal was to explore the feasibility and acceptability of monitoring of gait and falls in the homes of persons with MS over a period of 30 days. To test the feasibility of measuring gait and falls for 30days in the home of persons with MS, spatiotemporal gait parameters stride length, stride time, and gait speed were compared. A 3D infrared depth imaging system has been developed to objectively measure gait and falls in the home environment. Participants also completed a 16-foot GaitRite electronic pathway walk to validate spatiotemporal parameters of gait (gait speed (cm/s), stride length (cm), and gait cycle time(s)) during the timed 25 foot walking test (T25FWT). We also documented barriers to feasibility of installing the in-home sensors for these participants. The results of the study suggest that the Kinect sensor may be used as an alternative device to measure gait for persons with MS, depending on the desired accuracy level. Ultimately, using in-home sensors to analyze gait parameters in real time is feasible and could lead to better analysis of gait in persons with MS. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. [Subjective Gait Stability in the Elderly].

    PubMed

    Hirsch, Theresa; Lampe, Jasmin; Michalk, Katrin; Röder, Lotte; Munsch, Karoline; Marquardt, Jonas

    2017-07-10

    It can be assumed that the feeling of gait stability or gait instability in the elderly may be independent of a possible fear of falling or a history of falling when walking. Up to now, there has been a lack of spatiotemporal gait parameters for older people who subjectively feel secure when walking. The aim of the study is to analyse the distribution of various gait parameters for older people who subjectively feel secure when walking. In a cross-sectional study, the gait parameters stride time, step time, stride length, step length, double support, single support, and walking speed were measured using a Vicon three-dimensional motion capture system (Plug-In Gait Lower-Body Marker Set) in 31 healthy people aged 65 years and older (mean age 72 ± 3.54 years) who subjectively feel secure when walking. There was a homogeneous distribution in the gait parameters examined, with no abnormalities. The mean values have a low variance with narrow confidence intervals. This study provides evidence that people who subjectively feel secure when walking demonstrate similarly objective gait parameters..

  6. Objective assessment of gait in xylazine-induced ataxic horses.

    PubMed

    Nout-Lomas, Y S; Page, K M; Kang, H G; Aanstoos, M E; Greene, H M

    2017-05-01

    There is poor agreement between observers of equine neurological gait abnormalities using the modified Mayhew grading scale. To stimulate a dose-dependent ataxia in horses through xylazine administration and identify quantifiable relevant gait parameters. Balanced, randomised, 2-way crossover design. Eight horses were assessed before and after administration of xylazine (low dose and high dose). Gait analyses performed before and after xylazine administration included: 1) kinematic data collected on an equine high-speed treadmill (flat and 10% decline) and from accelerometers placed on head and sacrum; and 2) kinetic data collected on a force plate. All horses developed dose-dependent ataxia. Horses developed a dose-dependent increased stride time, stride length, and time of contact (P<0.0001), and a decreased stride frequency (P<0.0002) after administration of xylazine. Although pelvic acceleration increased in the mediolateral direction (P<0.05) in horses walked on the treadmill, this movement decreased when walking over ground after administration of xylazine (P<0.05). Furthermore, centre of pressure and path length indices changed significantly in horses following administration of xylazine (P<0.05). This study examined one breed of horse (Arabian), all of similar height and weight. Accelerometers were attached to skin, not bone; no correction was made for artefacts from skin displacement. The sedative drug effect is of certain duration, limiting the data collection period. Administration of xylazine induced a dose-dependent ataxia in horses and resulted in significant changes of gait parameters, pelvic accelerations, and stabilographic variables, some of which changed in a dose-dependent fashion. Some of the altered gait parameters in this model were probably a result of overall slowing down of the stride cycle secondary to the sedative effect. Continued efforts to discover and evaluate quantifiable gait parameters that are susceptible to change following

  7. Kinematic Analysis Quantifies Gait Abnormalities Associated with Lameness in Broiler Chickens and Identifies Evolutionary Gait Differences

    PubMed Central

    Caplen, Gina; Hothersall, Becky; Murrell, Joanna C.; Nicol, Christine J.; Waterman-Pearson, Avril E.; Weeks, Claire A.; Colborne, G. Robert

    2012-01-01

    This is the first time that gait characteristics of broiler (meat) chickens have been compared with their progenitor, jungle fowl, and the first kinematic study to report a link between broiler gait parameters and defined lameness scores. A commercial motion-capturing system recorded three-dimensional temporospatial information during walking. The hypothesis was that the gait characteristics of non-lame broilers (n = 10) would be intermediate to those of lame broilers (n = 12) and jungle fowl (n = 10, tested at two ages: immature and adult). Data analysed using multi-level models, to define an extensive range of baseline gait parameters, revealed inter-group similarities and differences. Natural selection is likely to have made jungle fowl walking gait highly efficient. Modern broiler chickens possess an unbalanced body conformation due to intense genetic selection for additional breast muscle (pectoral hypertrophy) and whole body mass. Together with rapid growth, this promotes compensatory gait adaptations to minimise energy expenditure and triggers high lameness prevalence within commercial flocks; lameness creating further disruption to the gait cycle and being an important welfare issue. Clear differences were observed between the two lines (short stance phase, little double-support, low leg lift, and little back displacement in adult jungle fowl; much double-support, high leg lift, and substantial vertical back movement in sound broilers) presumably related to mass and body conformation. Similarities included stride length and duration. Additional modifications were also identified in lame broilers (short stride length and duration, substantial lateral back movement, reduced velocity) presumably linked to musculo-skeletal abnormalities. Reduced walking velocity suggests an attempt to minimise skeletal stress and/or discomfort, while a shorter stride length and time, together with longer stance and double-support phases, are associated with

  8. The effect of environment and task on gait parameters after stroke: A randomized comparison of measurement conditions.

    PubMed

    Lord, Susan E; Rochester, Lynn; Weatherall, Mark; McPherson, Kathryn M; McNaughton, Harry K

    2006-07-01

    To assess the effect of environment and a secondary task on gait parameters in community ambulant stroke survivors and to assess the contribution of clinical symptoms to gait performance. A 2x3 randomized factorial design with 2 main factors: task (no task, motor task, cognitive task) and environment (clinic, suburban street, shopping mall). Subjects were assessed in 1 of 3 settings: 2 in the community (a suburban street and shopping mall) and 1 clinical environment. Twenty-seven people with stroke (mean age, 61+/-11.6y; mean time since stroke onset, 45.8+/-34.2mo), living at home, were recruited from community stroke groups and from a local rehabilitation unit. Selection criteria included the following: ability to give informed consent, unilateral first ever or recurrent stroke at least 6 months previously, walking independently in the community, a gait speed between 24 and 50 m/min, Mini-Mental State Examination score of 24 or higher, and no severe comorbidity. Not applicable. Gait speed (in m/min), cadence, and step length were assessed by using an accelerometer with adjustable thresholds. Clinical measures hypothesized to influence gait parameters in community environments were also assessed including fatigue, anxiety and depression, and attentional deficit. Twenty-seven people with a mean baseline gait speed of 42.2+/-5.9 m/min were randomly allocated to 1 of 9 conditions in which the setting and distraction were manipulated. Analysis of variance showed a significant main effect for environment (P = .046) but not for task (P = .37). The interaction between task and environment was not significant (P = .73). Adjusting for baseline gait speed, people walked on average 8.8m/min faster in the clinic (95% confidence interval, 0.3-17.3m/min) than in the mall. Scores for fatigue, anxiety and depression, and attentional deficit were higher than normative values but did not influence gait performance. This study suggests that people with chronic stroke cope well with

  9. Good agreement between smart device and inertial sensor-based gait parameters during a 6-min walk.

    PubMed

    Proessl, F; Swanson, C W; Rudroff, T; Fling, B W; Tracy, B L

    2018-05-28

    Traditional laboratory-based kinetic and kinematic gait analyses are expensive, time-intensive, and impractical for clinical settings. Inertial sensors have gained popularity in gait analysis research and more recently smart devices have been employed to provide quantification of gait. However, no study to date has investigated the agreement between smart device and inertial sensor-based gait parameters during prolonged walking. Compare spatiotemporal gait metrics measured with a smart device versus previously validated inertial sensors. Twenty neurologically healthy young adults (7 women; age: 25.0 ± 3.7 years; BMI: 23.4 ± 2.9 kg/m 2 ) performed a 6-min walk test (6MWT) wearing inertial sensors and smart devices to record stride duration, stride length, cadence, and gait speed. Pearson correlations were used to assess associations between spatiotemporal measures from the two devices and agreement between the two methods was assessed with Bland-Altman plots and limits of agreement. All spatiotemporal gait metrics (stride duration, cadence, stride length and gait speed) showed strong (r>0.9) associations and good agreement between the two devices. Smart devices are capable of accurately reflecting many of the spatiotemporal gait metrics of inertial sensors. As the smart devices also accurately reflected individual leg output, future studies may apply this analytical strategy to clinical populations, to identify hallmarks of disability status and disease progression in a more ecologically valid environment. Copyright © 2018. Published by Elsevier B.V.

  10. A biofeedback cycling training to improve locomotion: a case series study based on gait pattern classification of 153 chronic stroke patients.

    PubMed

    Ferrante, Simona; Ambrosini, Emilia; Ravelli, Paola; Guanziroli, Eleonora; Molteni, Franco; Ferrigno, Giancarlo; Pedrocchi, Alessandra

    2011-08-24

    The restoration of walking ability is the main goal of post-stroke lower limb rehabilitation and different studies suggest that pedaling may have a positive effect on locomotion. The aim of this study was to explore the feasibility of a biofeedback pedaling treatment and its effects on cycling and walking ability in chronic stroke patients. A case series study was designed and participants were recruited based on a gait pattern classification of a population of 153 chronic stroke patients. In order to optimize participants selection, a k-means cluster analysis was performed to subgroup homogenous gait patterns in terms of gait speed and symmetry.The training consisted of a 2-week treatment of 6 sessions. A visual biofeedback helped the subjects in maintaining a symmetrical contribution of the two legs during pedaling. Participants were assessed before, after training and at follow-up visits (one week after treatment). Outcome measures were the unbalance during a pedaling test, and the temporal, spatial, and symmetry parameters during gait analysis. Three clusters, mainly differing in terms of gait speed, were identified and participants, representative of each cluster, were selected.An intra-subject statistical analysis (ANOVA) showed that all patients significantly decreased the pedaling unbalance after treatment and maintained significant improvements with respect to baseline at follow-up. The 2-week treatment induced some modifications in the gait pattern of two patients: one, the most impaired, significantly improved mean velocity and increased gait symmetry; the other one reduced significantly the over-compensation of the healthy limb. No benefits were produced in the gait of the last subject who maintained her slow but almost symmetrical pattern. Thus, this study might suggest that the treatment can be beneficial for patients having a very asymmetrical and inefficient gait and for those that overuse the healthy leg. The results demonstrated that the treatment

  11. A biofeedback cycling training to improve locomotion: a case series study based on gait pattern classification of 153 chronic stroke patients

    PubMed Central

    2011-01-01

    Background The restoration of walking ability is the main goal of post-stroke lower limb rehabilitation and different studies suggest that pedaling may have a positive effect on locomotion. The aim of this study was to explore the feasibility of a biofeedback pedaling treatment and its effects on cycling and walking ability in chronic stroke patients. A case series study was designed and participants were recruited based on a gait pattern classification of a population of 153 chronic stroke patients. Methods In order to optimize participants selection, a k-means cluster analysis was performed to subgroup homogenous gait patterns in terms of gait speed and symmetry. The training consisted of a 2-week treatment of 6 sessions. A visual biofeedback helped the subjects in maintaining a symmetrical contribution of the two legs during pedaling. Participants were assessed before, after training and at follow-up visits (one week after treatment). Outcome measures were the unbalance during a pedaling test, and the temporal, spatial, and symmetry parameters during gait analysis. Results and discussion Three clusters, mainly differing in terms of gait speed, were identified and participants, representative of each cluster, were selected. An intra-subject statistical analysis (ANOVA) showed that all patients significantly decreased the pedaling unbalance after treatment and maintained significant improvements with respect to baseline at follow-up. The 2-week treatment induced some modifications in the gait pattern of two patients: one, the most impaired, significantly improved mean velocity and increased gait symmetry; the other one reduced significantly the over-compensation of the healthy limb. No benefits were produced in the gait of the last subject who maintained her slow but almost symmetrical pattern. Thus, this study might suggest that the treatment can be beneficial for patients having a very asymmetrical and inefficient gait and for those that overuse the healthy leg

  12. Bipedal gait model for precise gait recognition and optimal triggering in foot drop stimulator: a proof of concept.

    PubMed

    Shaikh, Muhammad Faraz; Salcic, Zoran; Wang, Kevin I-Kai; Hu, Aiguo Patrick

    2018-03-10

    Electrical stimulators are often prescribed to correct foot drop walking. However, commercial foot drop stimulators trigger inappropriately under certain non-gait scenarios. Past researches addressed this limitation by defining stimulation control based on automaton of a gait cycle executed by foot drop of affected limb/foot only. Since gait is a collaborative activity of both feet, this research highlights the role of normal foot for robust gait detection and stimulation triggering. A novel bipedal gait model is proposed where gait cycle is realized as an automaton based on concurrent gait sub-phases (states) from each foot. The input for state transition is fused information from feet-worn pressure and inertial sensors. Thereafter, a bipedal gait model-based stimulation control algorithm is developed. As a feasibility study, bipedal gait model and stimulation control are evaluated in real-time simulation manner on normal and simulated foot drop gait measurements from 16 able-bodied participants with three speed variations, under inappropriate triggering scenarios and with foot drop rehabilitation exercises. Also, the stimulation control employed in commercial foot drop stimulators and single foot gait-based foot drop stimulators are compared alongside. Gait detection accuracy (98.9%) and precise triggering under all investigations prove bipedal gait model reliability. This infers that gait detection leveraging bipedal periodicity is a promising strategy to rectify prevalent stimulation triggering deficiencies in commercial foot drop stimulators. Graphical abstract Bipedal information-based gait recognition and stimulation triggering.

  13. The Influence of a Cognitive Dual Task on the Gait Parameters of Healthy Older Adults: A Systematic Review and Meta-Analysis.

    PubMed

    Smith, Erin; Cusack, Tara; Cunningham, Caitriona; Blake, Catherine

    2017-10-01

    This review examines the effect of a dual task on the gait parameters of older adults with a mean gait speed of 1.0 m/s or greater, and the effect of type and complexity of task. A systematic review of Web of Science, PubMed, SCOPUS, Embase, and PsycINFO was performed in July 2016. Twenty-three studies (28 data sets) were reviewed and pooled for meta-analysis. The effect size on seven gait parameters was measured as the raw mean difference between single- and dual-task performance. Gait speed significantly reduced with the addition of a dual task, with increasing complexity showing greater decrements. Cadence, stride time, and measures of gait variability were all negatively affected under the dual-task condition. In older adults, the addition of a dual task significantly reduces gait speed and cadence, with possible implications for the assessment of older people, as the addition of a dual task may expose deficits not observed under single-task assessment.

  14. An Inverse Kinematic Approach Using Groebner Basis Theory Applied to Gait Cycle Analysis

    DTIC Science & Technology

    2013-03-01

    stance phase begins with initial contact, heel strike , and ends with toe off. The swing phase begins at toe off and ends with the heel striking the ground...and transition phase (10%). Recall, that the gait cycle begins when the heel strikes the ground of one foot and ends when that same foot strikes the...Validation of Knee Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 12 Validation of Ankle Angle

  15. Gait and Functional Mobility Deficits in Fragile X-Associated Tremor/Ataxia Syndrome.

    PubMed

    O'Keefe, Joan A; Robertson-Dick, Erin E; Hall, Deborah A; Berry-Kravis, Elizabeth

    2016-08-01

    Fragile X-associated tremor/ataxia syndrome (FXTAS) results from a "premutation" (PM) size CGG repeat expansion in the fragile X mental retardation 1 (FMR1) gene. Cerebellar gait ataxia is the primary feature in some FXTAS patients causing progressive disability. However, no studies have quantitatively characterized gait and mobility deficits in FXTAS. We performed quantitative gait and mobility analysis in seven FMR1 PM carriers with FXTAS and ataxia, six PM carriers without FXTAS, and 18 age-matched controls. We studied four independent gait domains, trunk range of motion (ROM), and movement transitions using an instrumented Timed Up and Go (i-TUG). We correlated these outcome measures with FMR1 molecular variables and clinical severity scales. PM carriers with FXTAS were globally impaired in every gait performance domain except trunk ROM compared to controls. These included total i-TUG duration, stride velocity, gait cycle time, cadence, double-limb support and swing phase times, turn duration, step time before turn, and turn-to-sit duration, and increased gait variability on several measures. Carriers without FXTAS did not differ from controls on any parameters, but double-limb support time was close to significance. Balance and disability scales correlated with multiple gait and movement transition parameters, while the FXTAS Rating Scale did not. This is the first study to quantitatively examine gait and movement transitions in FXTAS patients. Gait characteristics were consistent with those from previous cohorts with cerebellar ataxia. Sensitive measures like the i-TUG may help determine efficacy of interventions, characterize disease progression, and provide early markers of disease in FXTAS.

  16. Increased lower limb muscle coactivation reduces gait performance and increases metabolic cost in patients with hereditary spastic paraparesis.

    PubMed

    Rinaldi, Martina; Ranavolo, Alberto; Conforto, Silvia; Martino, Giovanni; Draicchio, Francesco; Conte, Carmela; Varrecchia, Tiwana; Bini, Fabiano; Casali, Carlo; Pierelli, Francesco; Serrao, Mariano

    2017-10-01

    The aim of this study was to investigate the lower limb muscle coactivation and its relationship with muscles spasticity, gait performance, and metabolic cost in patients with hereditary spastic paraparesis. Kinematic, kinetic, electromyographic and energetic parameters of 23 patients and 23 controls were evaluated by computerized gait analysis system. We computed ankle and knee antagonist muscle coactivation indexes throughout the gait cycle and during the subphases of gait. Energy consumption and energy recovery were measured as well. In addition to the correlation analysis between coactivation indexes and clinical variables, correlations between coactivation indexes and time-distance, kinematic, kinetic, and energetic parameters were estimated. Increased coactivity indexes of both knee and ankle muscles throughout the gait cycle and during the subphases of gait were observed in patients compared with controls. Energetic parameters were significantly higher in patients than in controls. Both knee and ankle muscle coactivation indexes were positively correlated with knee and ankle spasticity (Ashworth score), respectively. Knee and ankle muscle coactivation indexes were both positively correlated with energy consumption and both negatively correlated with energy recovery. Positive correlations between the Ashworth score and lower limb muscle coactivation suggest that abnormal lower limb muscle coactivation in patients with hereditary spastic paraparesis reflects a primary deficit linked to lower limb spasticity. Furthermore, these abnormalities influence the energetic mechanisms during walking. Identifying excessive muscle coactivation may be helpful in individuating the rehabilitative treatments and designing specific orthosis to restrain spasticity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Gait parameter and event estimation using smartphones.

    PubMed

    Pepa, Lucia; Verdini, Federica; Spalazzi, Luca

    2017-09-01

    The use of smartphones can greatly help for gait parameters estimation during daily living, but its accuracy needs a deeper evaluation against a gold standard. The objective of the paper is a step-by-step assessment of smartphone performance in heel strike, step count, step period, and step length estimation. The influence of smartphone placement and orientation on estimation performance is evaluated as well. This work relies on a smartphone app developed to acquire, process, and store inertial sensor data and rotation matrices about device position. Smartphone alignment was evaluated by expressing the acceleration vector in three reference frames. Two smartphone placements were tested. Three methods for heel strike detection were considered. On the basis of estimated heel strikes, step count is performed, step period is obtained, and the inverted pendulum model is applied for step length estimation. Pearson correlation coefficient, absolute and relative errors, ANOVA, and Bland-Altman limits of agreement were used to compare smartphone estimation with stereophotogrammetry on eleven healthy subjects. High correlations were found between smartphone and stereophotogrammetric measures: up to 0.93 for step count, to 0.99 for heel strike, 0.96 for step period, and 0.92 for step length. Error ranges are comparable to those in the literature. Smartphone placement did not affect the performance. The major influence of acceleration reference frames and heel strike detection method was found in step count. This study provides detailed information about expected accuracy when smartphone is used as a gait monitoring tool. The obtained results encourage real life applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Development and validity of methods for the estimation of temporal gait parameters from heel-attached inertial sensors in younger and older adults.

    PubMed

    Misu, Shogo; Asai, Tsuyoshi; Ono, Rei; Sawa, Ryuichi; Tsutsumimoto, Kota; Ando, Hiroshi; Doi, Takehiko

    2017-09-01

    The heel is likely a suitable location to which inertial sensors are attached for the detection of gait events. However, there are few studies to detect gait events and determine temporal gait parameters using sensors attached to the heels. We developed two methods to determine temporal gait parameters: detecting heel-contact using acceleration and detecting toe-off using angular velocity data (acceleration-angular velocity method; A-V method), and detecting both heel-contact and toe-off using angular velocity data (angular velocity-angular velocity method; V-V method). The aim of this study was to examine the concurrent validity of the A-V and V-V methods against the standard method, and to compare their accuracy. Temporal gait parameters were measured in 10 younger and 10 older adults. The intra-class correlation coefficients were excellent in both methods compared with the standard method (0.80 to 1.00). The root mean square errors of stance and swing time in the A-V method were smaller than the V-V method in older adults, although there were no significant discrepancies in the other comparisons. Our study suggests that inertial sensors attached to the heels, using the A-V method in particular, provide a valid measurement of temporal gait parameters. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Effects of Nordic walking and walking on spatiotemporal gait parameters and ground reaction force.

    PubMed

    Park, Seung Kyu; Yang, Dae Jung; Kang, Yang Hun; Kim, Je Ho; Uhm, Yo Han; Lee, Yong Seon

    2015-09-01

    [Purpose] The purpose of this study was to investigate the effects of Nordic walking and walking on spatiotemporal gait parameters and ground reaction force. [Subjects] The subjects of this study were 30 young adult males, who were divided into a Nordic walking group of 15 subjects and a walking group of 15 subjects. [Methods] To analyze the spatiotemporal parameters and ground reaction force during walking in the two groups, the six-camera Vicon MX motion analysis system was used. The subjects were asked to walk 12 meters using the more comfortable walking method for them between Nordic walking and walking. After they walked 12 meters more than 10 times, their most natural walking patterns were chosen three times and analyzed. To determine the pole for Nordic walking, each subject's height was multiplied by 0.68. We then measured the spatiotemporal gait parameters and ground reaction force. [Results] Compared with the walking group, the Nordic walking group showed an increase in cadence, stride length, and step length, and a decrease in stride time, step time, and vertical ground reaction force. [Conclusion] The results of this study indicate that Nordic walking increases the stride and can be considered as helping patients with diseases affecting their gait. This demonstrates that Nordic walking is more effective in improving functional capabilities by promoting effective energy use and reducing the lower limb load, because the weight of the upper and lower limbs is dispersed during Nordic walking.

  20. Effects of Vojta Therapy on Gait of Children with Spastic Diplegia

    PubMed Central

    Lim, Hyungwon; Kim, Tackhoon

    2014-01-01

    [Purpose] This study aimed to investigate the effects of Vojta therapy on spatiotemporal gait parameters in children with spastic diplegia. [Methods] The study population consisted of 3 children diagnosed with spastic diplegia. The subjects were treated with Vojta therapy for 8 weeks and followed up for 8 weeks after completion of the therapy. Vicon motion analysis was used to determine the subjects’ spatiotemporal gait parameters. [Results] The following results were noted in the changes of each joint angle in the sagittal plane after Vojta therapy. Subject 1 remained in phase throughout the entire gait cycle and did not show any noticeable improvement, even demonstrating a negative range of motion when compared to the baseline. Subject 2 showed a normal anti-phase in heel strike, and the mid-stance, and swing phases. Subject 3 showed a normal anti-phase in heel strike and mid-stance, but the anti-phase during the swing phase was not significantly different from the baseline. For subjects 2 and 3, compared to the baseline, the range of motion of the hip and knee increased but the range of motion of the ankle decreased. [Conclusion] The findings of this study indicate that Vojta therapy can do a good role in improve the spatiotemporal gait parameters of children with spastic diplegia. PMID:24409030

  1. Clinical gait evaluation of patients with knee osteoarthritis.

    PubMed

    Sun, Jun; Liu, Yancheng; Yan, Songhua; Cao, Guanglei; Wang, Shasha; Lester, D Kevin; Zhang, Kuan

    2017-10-01

    Knee osteoarthritis (KOA) is the most common osteoarthritis in lower limbs, and gait measurement is important to evaluate walking function of KOA patients before and after treatment. The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3) is a portable gait analysis system to evaluate gaits. This study is to evaluate the accuracy and reliability of IDEEA3 for gait measurement of KOA patients. Meanwhile, gait differences between KOA patients and healthy subjects are examined. Twelve healthy volunteers were recruited for measurement comparison of gait cycle (GC), cadence, step length, velocity and step counts between a motion analysis system and a high-speed camera (GoPro Hero3). Twenty-three KOA patients were recruited for measurement comparison of former five parameters between GoPro Hero3 and IDEEA3. Paired t-test, Concordance Correlation Coefficient (CCC) and Intraclass Correlation Coefficient (ICC) were used for data analysis. All p-values of paired t-tests for GC, cadence, step length and velocity were greater than 0.05 while all CCC and ICC results were above 0.95. The measurements of GC, cadence, step length, velocity and step counts by motion analysis system are highly consistent with the measurements by GoPro Hero3. The measurements of former parameters by GoPro Hero3 are not statistically different from the measurements by IDEEA3. IDEEA3 can be effectively used for the measurement of GC, cadence, step length, velocity and step counts in KOA patients. The KOA patients walk with longer GC, lower cadence, shorter step length and slower speed compared with healthy subjects in natural speed with flat shoes. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Automated gait and balance parameters diagnose and correlate with severity in Parkinson disease.

    PubMed

    Dewey, D Campbell; Miocinovic, Svjetlana; Bernstein, Ira; Khemani, Pravin; Dewey, Richard B; Querry, Ross; Chitnis, Shilpa; Dewey, Richard B

    2014-10-15

    To assess the suitability of instrumented gait and balance measures for diagnosis and estimation of disease severity in PD. Each subject performed iTUG (instrumented Timed-Up-and-Go) and iSway (instrumented Sway) using the APDM(®) Mobility Lab. MDS-UPDRS parts II and III, a postural instability and gait disorder (PIGD) score, the mobility subscale of the PDQ-39, and Hoehn & Yahr stage were measured in the PD cohort. Two sets of gait and balance variables were defined by high correlation with diagnosis or disease severity and were evaluated using multiple linear and logistic regressions, ROC analyses, and t-tests. 135 PD subjects and 66 age-matched controls were evaluated in this prospective cohort study. We found that both iTUG and iSway variables differentiated PD subjects from controls (area under the ROC curve was 0.82 and 0.75 respectively) and correlated with all PD severity measures (R(2) ranging from 0.18 to 0.61). Objective exam-based scores correlated more strongly with iTUG than iSway. The chosen set of iTUG variables was abnormal in very mild disease. Age and gender influenced gait and balance parameters and were therefore controlled in all analyses. Our study identified sets of iTUG and iSway variables which correlate with PD severity measures and differentiate PD subjects from controls. These gait and balance measures could potentially serve as markers of PD progression and are under evaluation for this purpose in the ongoing NIH Parkinson Disease Biomarker Program. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Automated Gait and Balance Parameters Diagnose and Correlate with Severity in Parkinson Disease

    PubMed Central

    Dewey, Daniel C.; Miocinovic, Svjetlana; Bernstein, Ira; Khemani, Pravin; Dewey, Richard B.; Querry, Ross; Chitnis, Shilpa; Dewey, Richard B.

    2014-01-01

    Objective To assess the suitability of instrumented gait and balance measures for diagnosis and estimation of disease severity in PD. Methods Each subject performed iTUG (instrumented Timed-Up-and-Go) and iSway (instrumented Sway) using the APDM® Mobility Lab. MDS-UPDRS parts II and III, a postural instability and gait disorder (PIGD) score, the mobility subscale of the PDQ-39, and Hoehn & Yahr stage were measured in the PD cohort. Two sets of gait and balance variables were defined by high correlation with diagnosis or disease severity and were evaluated using multiple linear and logistic regressions, ROC analyses, and t-tests. Results 135 PD subjects and 66 age-matched controls were evaluated in this prospective cohort study. We found that both iTUG and iSway variables differentiated PD subjects from controls (area under the ROC curve was 0.82 and 0.75 respectively) and correlated with all PD severity measures (R2 ranging from 0.18 to 0.61). Objective exam-based scores correlated more strongly with iTUG than iSway. The chosen set of iTUG variables was abnormal in very mild disease. Age and gender influenced gait and balance parameters and were therefore controlled in all analyses. Interpretation Our study identified sets of iTUG and iSway variables which correlate with PD severity measures and differentiate PD subjects from controls. These gait and balance measures could potentially serve as markers of PD progression and are under evaluation for this purpose in the ongoing NIH Parkinson Disease Biomarker Program. PMID:25082782

  4. Surface Peroneal Nerve Stimulation in Lower Limb Hemiparesis: Effect on Quantitative Gait Parameters

    PubMed Central

    Sheffler, Lynne R.; Taylor, Paul N.; Bailey, Stephanie Nogan; Gunzler, Douglas D.; Buurke, Jaap H.; IJzerman, Maarten J.; Chae, John

    2015-01-01

    Objective To evaluate possible mechanisms for functional improvement and compare ambulation training with surface peroneal nerve stimulation (PNS) versus usual care (UC) via quantitative gait analysis. Design Randomized controlled clinical trial. Setting Teaching hospital of academic medical center. Participants 110 chronic stroke survivors (> 12-wks post-stroke) with unilateral hemiparesis. Interventions Subjects were randomized to a surface PNS device or UC intervention. Subjects were treated for 12-wks and followed for 6-months post-treatment. Main Outcome Measures Spatiotemporal, kinematic, and kinetic parameters of gait. Results Cadence (F3,153=5.81, p=.012), stride length (F3,179=20.01, p<.001), walking speed (F3,167=18.2, p<.001), anterior posterior ground reaction force (F3,164=6.61, p=.004), peak hip power in pre-swing (F3,156=8.76, p<.001), and peak ankle power at push-off (F3,149=6.38, p=.005) all improved with respect to time. However, peak ankle DF in swing (F3,184=4.99, p=.031) worsened. In general, the greatest change for all parameters occurred during the treatment period. There was no significant treatment group by time interaction effects for any of the spatiotemporal, kinematic, or kinetic parameters. Conclusions Gait training with PNS and usual care was associated with improvements in peak hip power in pre-swing and peak ankle power at push-off, which may have resulted in improved cadence, stride length, and walking speed; however, there were no differences between treatment groups. Both treatment groups also experienced a decrease in peak ankle DF in swing, though the clinical implications of this finding are unclear. PMID:25802966

  5. Effect of body weight support variation on muscle activities during robot assisted gait: a dynamic simulation study.

    PubMed

    Hussain, Shahid; Jamwal, Prashant K; Ghayesh, Mergen H

    2017-05-01

    While body weight support (BWS) intonation is vital during conventional gait training of neurologically challenged subjects, it is important to evaluate its effect during robot assisted gait training. In the present research we have studied the effect of BWS intonation on muscle activities during robotic gait training using dynamic simulations. Two dimensional (2-D) musculoskeletal model of human gait was developed conjointly with another 2-D model of a robotic orthosis capable of actuating hip, knee and ankle joints simultaneously. The musculoskeletal model consists of eight major muscle groups namely; soleus (SOL), gastrocnemius (GAS), tibialis anterior (TA), hamstrings (HAM), vasti (VAS), gluteus maximus (GLU), uniarticular hip flexors (iliopsoas, IP), and Rectus Femoris (RF). BWS was provided at levels of 0, 20, 40 and 60% during the simulations. In order to obtain a feasible set of muscle activities during subsequent gait cycles, an inverse dynamics algorithm along with a quadratic minimization algorithm was implemented. The dynamic parameters of the robot assisted human gait such as joint angle trajectories, ground contact force (GCF), human limb joint torques and robot induced torques at different levels of BWS were derived. The patterns of muscle activities at variable BWS were derived and analysed. For most part of the gait cycle (GC) the muscle activation patterns are quite similar for all levels of BWS as is apparent from the mean of muscle activities for the complete GC. Effect of BWS variation during robot assisted gait on muscle activities was studied by developing dynamic simulation. It is expected that the proposed dynamic simulation approach will provide important inferences and information about the muscle function variations consequent upon a change in BWS during robot assisted gait. This information shall be quite important while investigating the influence of BWS intonation on neuromuscular parameters of interest during robotic gait training.

  6. Quantitative assessment of gait and neurochemical correlation in a classical murine model of Parkinson's disease.

    PubMed

    Wang, Xiao Hong; Lu, Gang; Hu, Xiang; Tsang, Kam Sze; Kwong, Wing Hang; Wu, Feng Xia; Meng, Hai Wei; Jiang, Shu; Liu, Shu Wei; Ng, Ho Keung; Poon, Wai Sang

    2012-11-14

    Gait deficits are important clinical symptoms of Parkinson's disease (PD). However, existing behavioral tests for the detection of motor impairments in rodents with systemic dopamine depletion only measure akinesia and dyskinesia, and data focusing on gait are scarce. We evaluated gait changes in the methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-induced C57BL/6 murine model of PD by using a computer-assisted CatWalk system. Correlations of gait parameters with tyrosine hydroxylase (TH) protein levels in the substantia nigra (SN) were also investigated. The gait readouts, including the walking duration, variation of walking speed, step cycle, duty cycle, stance, initial dual stance, terminal dual stance, three- and four-point supports, and the base of support between hind limbs was noted to increase significantly one week after MPTP injection. In contrast, values of the stride length, cadence, swing speed, and diagonal dual support decreased substantially following MPTP treatment (p < 0.05). All of these changes lasted for three weeks after the last MPTP administration. Except for the stance in the fore limbs and the swing speed in the hind limbs, the gait variability in the PD mice showed a closer correlation with the protein levels of TH in the SN than the walking distances in the conventional open field test. Coordination parameters of the regularity index and step pattern were not affected in mice treated with MPTP. Data of the study suggest that the computer-assisted CatWalk system can provide reliable and objective criteria to stratify gait changes arising from MPTP-induced bilateral lesions in C57/BL6 mice. The extent of gait changes was noted to correlate with the expression of the biomarker for dopaminergic neurons. This novel analytical method may hold promise in the study of disease progression and new drug screening in a murine PD model.

  7. Three-Dimensional Trunk and Lower Limbs Characteristics during Gait in Patients with Huntington's Disease.

    PubMed

    Mirek, Elzbieta; Filip, Magdalena; Chwała, Wiesław; Banaszkiewicz, Krzysztof; Rudzinska-Bar, Monika; Szymura, Jadwiga; Pasiut, Szymon; Szczudlik, Andrzej

    2017-01-01

    Objective: A number of studies on gait disturbances have been conducted, however, no clear pattern of gait disorders was described. The aim of the study was to characterize the gait pattern in HD patients by conducting analysis of mean angular movement changes the lower limb joints and trunk (kinematics parameters). Methods: The study group consisted of 30 patients with HD (17 women and 13 men). The reference data include the results of 30 healthy subjects (17 women and 13 men). Registration of gait with the Vicon 250 system was performed using passive markers attached to specific anthropometric points directly on the skin, based on the Golem biomechanical model (Oxford Metrics Ltd.). The research group and the control group were tested once. Results: Statistically significant ( p < 0.05) angular changes in gait cycle for HD patients were observed in: insufficient plantar flexion during Loading Response and Pre-swing phases; insufficient flexion of the knee joint during Initial Swing and Mid Swing phases; excessive flexion of the hip in Terminal Stance and Pre-swing phases and over-normative forward inclination of the trunk in all gait phases. It should be noted that the group of patients with HD obtained, for all the mean angular movement changes higher standard deviation. Conclusion: A characteristic gait disorder common to all patients with HD occurring throughout the whole duration of the gait cycle is a pathological anterior tilt of the trunk. The results will significantly contribute to programming physiotherapy for people with HD, aimed at stabilizing the trunk in a position of extension during gait.

  8. Reliability and comparison of Kinect-based methods for estimating spatiotemporal gait parameters of healthy and post-stroke individuals.

    PubMed

    Latorre, Jorge; Llorens, Roberto; Colomer, Carolina; Alcañiz, Mariano

    2018-04-27

    Different studies have analyzed the potential of the off-the-shelf Microsoft Kinect, in its different versions, to estimate spatiotemporal gait parameters as a portable markerless low-cost alternative to laboratory grade systems. However, variability in populations, measures, and methodologies prevents accurate comparison of the results. The objective of this study was to determine and compare the reliability of the existing Kinect-based methods to estimate spatiotemporal gait parameters in healthy and post-stroke adults. Forty-five healthy individuals and thirty-eight stroke survivors participated in this study. Participants walked five meters at a comfortable speed and their spatiotemporal gait parameters were estimated from the data retrieved by a Kinect v2, using the most common methods in the literature, and by visual inspection of the videotaped performance. Errors between both estimations were computed. For both healthy and post-stroke participants, highest accuracy was obtained when using the speed of the ankles to estimate gait speed (3.6-5.5 cm/s), stride length (2.5-5.5 cm), and stride time (about 45 ms), and when using the distance between the sacrum and the ankles and toes to estimate double support time (about 65 ms) and swing time (60-90 ms). Although the accuracy of these methods is limited, these measures could occasionally complement traditional tools. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Spatiotemporal and Kinematic Parameters Relating to Oriented Gait and Turn Performance in Patients with Chronic Stroke

    PubMed Central

    Bonnyaud, Céline; Pradon, Didier; Vuillerme, Nicolas; Bensmail, Djamel; Roche, Nicolas

    2015-01-01

    Background The timed up and go test (TUG) is a functional test which is increasingly used to evaluate patients with stroke. The outcome measured is usually global TUG performance-time. Assessment of spatiotemporal and kinematic parameters during the Oriented gait and Turn sub-tasks of the TUG would provide a better understanding of the mechanisms underlying patients’ performance and therefore may help to guide rehabilitation. The aim of this study was thus to determine the spatiotemporal and kinematic parameters which were most related to the walking and turning sub-tasks of TUG performance in stroke patients. Methods 29 stroke patients carried out the TUG test which was recorded using an optoelectronic system in two conditions: spontaneous and standardized condition (standardized foot position and instructed to turn towards the paretic side). They also underwent a clinical assessment. Stepwise regression was used to determine the parameters most related to Oriented gait and Turn sub-tasks. Relationships between explanatory parameters of Oriented gait and Turn performance and clinical scales were evaluated using Spearman correlations. Results Step length and cadence explained 82% to 95% of the variance for the walking sub-tasks in both conditions. Percentage single support phase and contralateral swing phase (depending on the condition) respectively explained 27% and 56% of the variance during the turning sub-task in the spontaneous and standardized conditions. Discussion and Conclusion Step length, cadence, percentage of paretic single support phase and non-paretic swing phase, as well as dynamic stability were the main parameters related to TUG performance and they should be targeted in rehabilitation. PMID:26091555

  10. Quantitative assessment of gait and neurochemical correlation in a classical murine model of Parkinson’s disease

    PubMed Central

    2012-01-01

    Background Gait deficits are important clinical symptoms of Parkinson’s disease (PD). However, existing behavioral tests for the detection of motor impairments in rodents with systemic dopamine depletion only measure akinesia and dyskinesia, and data focusing on gait are scarce. We evaluated gait changes in the methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-induced C57BL/6 murine model of PD by using a computer-assisted CatWalk system. Correlations of gait parameters with tyrosine hydroxylase (TH) protein levels in the substantia nigra (SN) were also investigated. Results The gait readouts, including the walking duration, variation of walking speed, step cycle, duty cycle, stance, initial dual stance, terminal dual stance, three- and four-point supports, and the base of support between hind limbs was noted to increase significantly one week after MPTP injection. In contrast, values of the stride length, cadence, swing speed, and diagonal dual support decreased substantially following MPTP treatment (p < 0.05). All of these changes lasted for three weeks after the last MPTP administration. Except for the stance in the fore limbs and the swing speed in the hind limbs, the gait variability in the PD mice showed a closer correlation with the protein levels of TH in the SN than the walking distances in the conventional open field test. Coordination parameters of the regularity index and step pattern were not affected in mice treated with MPTP. Conclusion Data of the study suggest that the computer-assisted CatWalk system can provide reliable and objective criteria to stratify gait changes arising from MPTP-induced bilateral lesions in C57/BL6 mice. The extent of gait changes was noted to correlate with the expression of the biomarker for dopaminergic neurons. This novel analytical method may hold promise in the study of disease progression and new drug screening in a murine PD model. PMID:23151254

  11. What is the Best Configuration of Wearable Sensors to Measure Spatiotemporal Gait Parameters in Children with Cerebral Palsy?

    PubMed Central

    Carcreff, Lena; Paraschiv-Ionescu, Anisoara; De Coulon, Geraldo; Armand, Stéphane; Aminian, Kamiar

    2018-01-01

    Wearable inertial devices have recently been used to evaluate spatiotemporal parameters of gait in daily life situations. Given the heterogeneity of gait patterns in children with cerebral palsy (CP), the sensor placement and analysis algorithm may influence the validity of the results. This study aimed at comparing the spatiotemporal measurement performances of three wearable configurations defined by different sensor positioning on the lower limbs: (1) shanks and thighs, (2) shanks, and (3) feet. The three configurations were selected based on their potential to be used in daily life for children with CP and typically developing (TD) controls. For each configuration, dedicated gait analysis algorithms were used to detect gait events and compute spatiotemporal parameters. Fifteen children with CP and 11 TD controls were included. Accuracy, precision, and agreement of the three configurations were determined in comparison with an optoelectronic system as a reference. The three configurations were comparable for the evaluation of TD children and children with a low level of disability (CP-GMFCS I) whereas the shank-and-thigh-based configuration was more robust regarding children with a higher level of disability (CP-GMFCS II–III). PMID:29385700

  12. An integrated gait rehabilitation training based on Functional Electrical Stimulation cycling and overground robotic exoskeleton in complete spinal cord injury patients: Preliminary results.

    PubMed

    Mazzoleni, S; Battini, E; Rustici, A; Stampacchia, G

    2017-07-01

    The aim of this study is to investigate the effects of an integrated gait rehabilitation training based on Functional Electrical Stimulation (FES)-cycling and overground robotic exoskeleton in a group of seven complete spinal cord injury patients on spasticity and patient-robot interaction. They underwent a robot-assisted rehabilitation training based on two phases: n=20 sessions of FES-cycling followed by n= 20 sessions of robot-assisted gait training based on an overground robotic exoskeleton. The following clinical outcome measures were used: Modified Ashworth Scale (MAS), Numerical Rating Scale (NRS) on spasticity, Penn Spasm Frequency Scale (PSFS), Spinal Cord Independence Measure Scale (SCIM), NRS on pain and International Spinal Cord Injury Pain Data Set (ISCI). Clinical outcome measures were assessed before (T0) after (T1) the FES-cycling training and after (T2) the powered overground gait training. The ability to walk when using exoskeleton was assessed by means of 10 Meter Walk Test (10MWT), 6 Minute Walk Test (6MWT), Timed Up and Go test (TUG), standing time, walking time and number of steps. Statistically significant changes were found on the MAS score, NRS-spasticity, 6MWT, TUG, standing time and number of steps. The preliminary results of this study show that an integrated gait rehabilitation training based on FES-cycling and overground robotic exoskeleton in complete SCI patients can provide a significant reduction of spasticity and improvements in terms of patient-robot interaction.

  13. Temporo-spatial gait parameters during street crossing conditions: a comparison between younger and older adults.

    PubMed

    Vieira, Edgar R; Lim, Hyun-Hwa; Brunt, Denis; Hallal, Camilla Z; Kinsey, Laura; Errington, Lisa; Gonçalves, Mauro

    2015-02-01

    Most traffic accidents involving pedestrians happen during street crossing. Safe street crossing by older adults requires complex planning and imposes high cognitive demands. Understanding how street crossing situations affect younger and older adults' gait is important to create evidence-based policies, education and training. The objective of this study was to develop and test a method to evaluate temporo-spatial gait parameters of younger and older adults during simulated street crossing situations. Twenty-two younger (25±2 years old) and 22 older adults (73±6 years old) who lived independently in the community completed 3 walking trials at preferred gait speed and during simulated street crossing with regular and with reduced time. There were significant differences between groups (p<0.001) and conditions (p<0.001). Older adults' street crossing walking speed was higher than their preferred speed (p<0.001). Gait during simulated street crossing resulted in significant and progressive gait changes. The methods developed and tested can be used to (1) evaluate if people are at risk of falls and accidents during street crossing situations, (2) to compare among different groups, and (3) to help establish appropriate times for older pedestrians to cross streets safely. The current time to cross streets is too short even for healthy older adults. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Gait-Event-Based Synchronization Method for Gait Rehabilitation Robots via a Bioinspired Adaptive Oscillator.

    PubMed

    Chen, Gong; Qi, Peng; Guo, Zhao; Yu, Haoyong

    2017-06-01

    In the field of gait rehabilitation robotics, achieving human-robot synchronization is very important. In this paper, a novel human-robot synchronization method using gait event information is proposed. This method includes two steps. First, seven gait events in one gait cycle are detected in real time with a hidden Markov model; second, an adaptive oscillator is utilized to estimate the stride percentage of human gait using any one of the gait events. Synchronous reference trajectories for the robot are then generated with the estimated stride percentage. This method is based on a bioinspired adaptive oscillator, which is a mathematical tool, first proposed to explain the phenomenon of synchronous flashing among fireflies. The proposed synchronization method is implemented in a portable knee-ankle-foot robot and tested in 15 healthy subjects. This method has the advantages of simple structure, flexible selection of gait events, and fast adaptation. Gait event is the only information needed, and hence the performance of synchronization holds when an abnormal gait pattern is involved. The results of the experiments reveal that our approach is efficient in achieving human-robot synchronization and feasible for rehabilitation robotics application.

  15. Nonlinear dynamical model of human gait

    NASA Astrophysics Data System (ADS)

    West, Bruce J.; Scafetta, Nicola

    2003-05-01

    We present a nonlinear dynamical model of the human gait control system in a variety of gait regimes. The stride-interval time series in normal human gait is characterized by slightly multifractal fluctuations. The fractal nature of the fluctuations becomes more pronounced under both an increase and decrease in the average gait. Moreover, the long-range memory in these fluctuations is lost when the gait is keyed on a metronome. Human locomotion is controlled by a network of neurons capable of producing a correlated syncopated output. The central nervous system is coupled to the motocontrol system, and together they control the locomotion of the gait cycle itself. The metronomic gait is simulated by a forced nonlinear oscillator with a periodic external force associated with the conscious act of walking in a particular way.

  16. Comparison of standing postural control and gait parameters in people with and without chronic low back pain: a cross-sectional case-control study.

    PubMed

    MacRae, Catharine Siân; Critchley, Duncan; Lewis, Jeremy S; Shortland, Adam

    2018-01-01

    Differences in postural control and gait have been identified between people with and without chronic low back pain (CLBP); however, many previous studies present data from small samples, or have used methodologies with questionable reliability. This study, employing robust methodology, hypothesised that there would be a difference in postural control, and spatiotemporal parameters of gait in people with CLBP compared with asymptomatic individuals. This cross-sectional case-control study age-matched and gender-matched 16 CLBP and 16 asymptomatic participants. Participants were assessed barefoot (1) standing, over three 40 s trials, under four posture challenging conditions (2) during gait. Primary outcome was postural stability (assessed by root mean squared error of centre of pressure (CoP) displacement (CoP RMSEAP ) and mean CoP velocity (CoP VELAP ), both in the anteroposterior direction); gait outcomes were hip range of movement and peak moments, walking speed, cadence and stride length, assessed using force plates and a motion analysis system. There were no differences between groups in CoP RMSEAP (P=0.26), or CoP VELAP (P=0.60) for any standing condition. During gait, no differences were observed between groups for spatiotemporal parameters, maximum, minimum and total ranges of hip movement, or peak hip flexor or extensor moments in the sagittal plane. In contrast to previous research, this study suggests that people with mild to moderate CLBP present with similar standing postural control, and parameters of gait to asymptomatic individuals. Treatments directed at influencing postural stability (eg, standing on a wobble board) or specific parameters of gait may be an unnecessary addition to a treatment programme.

  17. Effect of investigator observation on gait parameters in individuals with and without chronic low back pain.

    PubMed

    Vickers, Joshua; Reed, Austin; Decker, Robert; Conrad, Bryan P; Olegario-Nebel, Marissa; Vincent, Heather K

    2017-03-01

    Despite the ubiquity of gait assessment in clinic and research, it is unclear how observation impacts gait, particularly in persons with chronic pain and psychological stress. We compared temporal spatial gait patterns in people with and without chronic low back pain (CLBP) when they were aware and unaware of being observed. This was a repeated-measures, deception study in 55 healthy persons (32.0±12.4 yr, 24.2±2.7kg/m 2 ) and persons with CLBP (51.9±17.9 yr, 27.8±4.4kg/m 2 ). Participants performed one condition in which they were unaware of observation (UNW), and three conditions under investigator observation: (1) aware of observation (AWA), (2) investigators watching cadence, (3) investigators watching step length. Participants walked across an 8.4m gait mat, while temporal spatial parameters of gait were collected. The Medical Outcomes Short Form (SF-12), Beck Depression Inventory (BDI), State Trait Anxiety Inventory (STAI), and Oswestry Disability Index (ODI) were completed. Significant condition by group interactions were found for velocity and step length (p<0.05). Main effects of study condition existed for all gait variables except for step width. Main effects of group (healthy, LBP) were significant for all variables except for step width (p<0.05). Regression analyses revealed that after accounting for age, sex, and SF-12 mental component score, BDI scores predict velocity changes during walking from the UNW to AWA conditions. These findings show that people change their gait patterns when being observed. Gait analyses may require additional trials before data can reliably be interpreted and used for clinical decision-making. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Improved kinect-based spatiotemporal and kinematic treadmill gait assessment.

    PubMed

    Eltoukhy, Moataz; Oh, Jeonghoon; Kuenze, Christopher; Signorile, Joseph

    2017-01-01

    A cost-effective, clinician friendly gait assessment tool that can automatically track patients' anatomical landmarks can provide practitioners with important information that is useful in prescribing rehabilitative and preventive therapies. This study investigated the validity and reliability of the Microsoft Kinect v2 as a potential inexpensive gait analysis tool. Ten healthy subjects walked on a treadmill at 1.3 and 1.6m·s -1 , as spatiotemporal parameters and kinematics were extracted concurrently using the Kinect and three-dimensional motion analysis. Spatiotemporal measures included step length and width, step and stride times, vertical and mediolateral pelvis motion, and foot swing velocity. Kinematic outcomes included hip, knee, and ankle joint angles in the sagittal plane. The absolute agreement and relative consistency between the two systems were assessed using interclass correlations coefficients (ICC2,1), while reproducibility between systems was established using Lin's Concordance Correlation Coefficient (rc). Comparison of ensemble curves and associated 90% confidence intervals (CI90) of the hip, knee, and ankle joint angles were performed to investigate if the Kinect sensor could consistently and accurately assess lower extremity joint motion throughout the gait cycle. Results showed that the Kinect v2 sensor has the potential to be an effective clinical assessment tool for sagittal plane knee and hip joint kinematics, as well as some spatiotemporal temporal variables including pelvis displacement and step characteristics during the gait cycle. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. The impact of time of day on the gait and balance control of Alzheimer's patients.

    PubMed

    Paillard, Thierry; Noé, Frederic; Bru, Noëlle; Couderc, Martine; Debove, Lola

    2016-01-01

    Alzheimer's patients suffer from circadian dysregulation. The aim of this study was to examine the evolution of balance control and gait at different times of the day (11:00, 14:00, 18:00) in order to identify whether Alzheimer's patients were more likely to fall at certain periods of the day. Spatio-temporal parameters of centre of foot pressure displacements were measured with a force platform and spatio-temporal parameters of walking were evaluated with a gait analysis device. The results highlighted that balance control was worse in the evening and the afternoon than in the morning. Furthermore, the walking speed was faster and support duration, swing duration and cycle duration were shorter in the evening than in the morning and afternoon. The combined analysis of balance control and gait parameters revealed that balance control and walking are concomitantly altered in the evening which increases the fall risk in the evening, in comparison with the morning, for Alzheimer's patients.

  20. Ground Reaction Forces and Gait Parameters during Motorized and Non-Motorized Treadmill Walking and Runing on the International Space Station Treadmill

    NASA Technical Reports Server (NTRS)

    Hagan, Ronald Donald; Norcross, Jason; DeWitt, John; Lee, Stuart M.; McCleary, Frank; Edwards, W. Brent

    2006-01-01

    Both motorized (T-M) and non-motorized (T-NM) treadmill locomotion are used on the International Space Station (ISS) as countermeasures to the deleterious effects of prolonged weightlessness. However, the ground reaction forces (GRF) and gait parameters of these exercise modes have not been examined. The purpose of this study was to determine if differences in GRF and gait parameters exist while walking (1.34 m/s) and running (3.13 m/s) on T-M and T-NM. Dissimilar GRF and gait parameters suggest that T-M and T-NM locomotion may elicit different physiologic effects. T-NM may result in a reduced stimulus to bone formation due to a lower LR, but an increased energy cost as a result of shorter, more frequent strides. Therefore, the usage of each mode should depend upon the desired training stimulus.

  1. Development of an advanced mechanised gait trainer, controlling movement of the centre of mass, for restoring gait in non-ambulant subjects.

    PubMed

    Hesse, S; Sarkodie-Gyan, T; Uhlenbrock, D

    1999-01-01

    The study aimed at further development of a mechanised gait trainer which would allow non-ambulant people to practice a gait-like motion repeatedly. To simulate normal gait, discrete stance and swing phases, lasting 60% and 40% of the gait cycle respectively, and the control of the movement of the centre of mass were required. A complex gear system provided the gait-like movement of two foot plates with a ratio of 60% to 40% between the stance and swing phases. A controlled propulsion system adjusted its output according to patient's efforts. Two eccenters on the central gear controlled phase-adjusted the vertical and horizontal position of the centre of mass. The patterns of sagittal lower limb joint kinematics and of muscle activation of a normal subject were similar when using the mechanised trainer and when walking on a treadmill. A non-ambulatory hemiparetic subject required little help from one therapist on the gait trainer, while two therapists supported treadmill walking. Gait movements on the trainer were highly symmetrical, impact-free, and less spastic. The weight-bearing muscles were activated in a similar fashion during both conditions. The vertical displacement of the centre of mass was bi-instead of mono-phasic during each gait cycle on the new device. In conclusion, the gait trainer allowed wheelchair-bound subjects the repetitive practice of a gait-like movement without overstraining therapists.

  2. Effects of treadmill training with load addition on non-paretic lower limb on gait parameters after stroke: A randomized controlled clinical trial.

    PubMed

    Ribeiro, Tatiana S; Silva, Emília M G S; Silva, Isaíra A P; Costa, Mayara F P; Cavalcanti, Fabrícia A C; Lindquist, Ana R

    2017-05-01

    The addition of load on the non-paretic lower limb for the purpose of restraining this limb and stimulating the use of the paretic limb has been suggested to improve hemiparetic gait. However, the results are conflicting and only short-term effects have been observed. This study aims to investigate the effects of adding load on non-paretic lower limb during treadmill gait training as a multisession intervention on kinematic gait parameters after stroke. With this aim, 38 subacute stroke patients (mean time since stroke: 4.5 months) were randomly divided into two groups: treadmill training with load (equivalent to 5% of body weight) on the non-paretic ankle (experimental group) and treadmill training without load (control group). Both groups performed treadmill training during 30min per day, for two consecutive weeks (nine sessions). Spatiotemporal and angular gait parameters were assessed by a motion system analysis at baseline, post-training (at the end of 9days of interventions) and follow-up (40days after the end of interventions). Several post-training effects were demonstrated: patients walked faster and with longer paretic and non-paretic steps compared to baseline, and maintained these gains at follow-up. In addition, patients exhibited greater hip and knee joint excursion in both limbs at post-training, while maintaining most of these benefits at follow-up. All these improvements were observed in both groups. Although the proposal gait training program has provided better gait parameters for these subacute stroke patients, our data indicate that load addition used as a restraint may not provide additional benefits to gait training. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Relationships between Isometric Muscle Strength, Gait Parameters, and Gross Motor Function Measure in Patients with Cerebral Palsy.

    PubMed

    Shin, Hyung Ik; Sung, Ki Hyuk; Chung, Chin Youb; Lee, Kyoung Min; Lee, Seung Yeol; Lee, In Hyeok; Park, Moon Seok

    2016-01-01

    This study investigated the correlation between isometric muscle strength, gross motor function, and gait parameters in patients with spastic cerebral palsy and to find which muscle groups play an important role for gait pattern in a flexed knee gait. Twenty-four ambulatory patients (mean age, 10.0 years) with spastic cerebral palsy who were scheduled for single event multilevel surgery, including distal hamstring lengthening, were included. Preoperatively, peak isometric muscle strength was measured for the hip flexor, hip extensor, knee flexor, and knee extensor muscle groups using a handheld dynamometer, and three-dimensional (3D) gait analysis and gross motor function measure (GMFM) scoring were also performed. Correlations between peak isometric strength and GMFM, gait kinematics, and gait kinetics were analyzed. Peak isometric muscle strength of all muscle groups was not related to the GMFM score and the gross motor function classification system level. Peak isometric strength of the hip extensor and knee extensor was significantly correlated with the mean pelvic tilt (r=-0.588, p=0.003 and r=-0.436, p=0.033) and maximum pelvic obliquity (r=-0.450, p=0.031 and r=-0.419, p=0.041). There were significant correlations between peak isometric strength of the knee extensor and peak knee extensor moment in early stance (r=0.467, p=0.021) and in terminal stance (r=0.416, p=0.043). There is no correlation between muscle strength and gross motor function. However, this study showed that muscle strength, especially of the extensor muscle group of the hip and knee joints, might play a critical role in gait by stabilizing pelvic motion and decreasing energy consumption in a flexed knee gait.

  4. Neurotomy of the rectus femoris nerve: Short-term effectiveness for spastic stiff knee gait: Clinical assessment and quantitative gait analysis.

    PubMed

    Gross, R; Robertson, J; Leboeuf, F; Hamel, O; Brochard, S; Perrouin-Verbe, B

    2017-02-01

    Stiff knee gait is a troublesome gait disturbance related to spastic paresis, frequently associated with overactivity of the rectus femoris muscle in the swing phase of gait. The aim of this study was to assess the short-term effects of rectus femoris neurotomy for the treatment of spastic stiff-knee gait in patients with hemiparesis. An Intervention study (before-after trial) with an observational design was carried out in a university hospital. Seven ambulatory patients with hemiparesis of spinal or cerebral origin and spastic stiff-knee gait, which had previously been improved by botulinum toxin injections, were proposed a selective neurotomy of the rectus femoris muscle. A functional evaluation (Functional Ambulation Classification and maximal walking distance), clinical evaluation (spasticity - Ashworth scale and Duncan-Ely test, muscle strength - Medical Research Council scale), and quantitative gait analysis (spatiotemporal parameters, stiff knee gait-related kinematic and kinetic parameters, and dynamic electromyography of rectus femoris) were performed as outcome measures, before and 3 months after rectus femoris neurotomy. Compared with preoperative values, there was a significant increase in maximal walking distance, gait speed, and stride length at 3 months. All kinematic parameters improved, and the average early swing phase knee extension moment decreased. The duration of the rectus femoris burst decreased post-op. This study is the first to show that rectus femoris neurotomy helps to normalise muscle activity during gait, and results in improvements in kinetic, kinematic, and functional parameters in patients with spastic stiff knee gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Basic gait analysis based on continuous wave radar.

    PubMed

    Zhang, Jun

    2012-09-01

    A gait analysis method based on continuous wave (CW) radar is proposed in this paper. Time-frequency analysis is used to analyze the radar micro-Doppler echo from walking humans, and the relationships between the time-frequency spectrogram and human biological gait are discussed. The methods for extracting the gait parameters from the spectrogram are studied in depth and experiments on more than twenty subjects have been performed to acquire the radar gait data. The gait parameters are calculated and compared. The gait difference between men and women are presented based on the experimental data and extracted features. Gait analysis based on CW radar will provide a new method for clinical diagnosis and therapy. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Inter- and intraobserver repeatability of the Salford Gait Tool: an observation-based clinical gait assessment tool.

    PubMed

    Toro, Brigitte; Nester, Christopher J; Farren, Pauline C

    2007-03-01

    To evaluate the inter- and intraobserver repeatability of the Salford Gait Tool (SF-GT), a new observation-based gait assessment tool for evaluating sagittal plane cerebral palsy (CP) gait. Masked comparative evaluation. University in the United Kingdom. A convenience sample of 23 pediatric physical therapists with varying degrees of clinical experience recruited from the Greater Manchester area. Participants viewed videotapes of the sagittal plane gait of 13 children and used the SF-GT to analyze their 13 different gait styles on 2 occasions. Eleven children had hemiplegic, diplegic, or quadriplegic CP and 2 were neurologically intact. Inter- and intraobserver repeatability of hip, knee, and ankle joint positions at 6 different phases of the gait cycle. The SF-GT demonstrated good interobserver (77%) and intraobserver (75%) repeatability. We have established that the SF-GT is a repeatable clinical assessment tool with which to guide the diagnosis, treatment planning, and evaluation of interventions by pediatric physical therapists of sagittal plane gait deviations in CP.

  7. Changes in gait patterns induced by rhythmic auditory stimulation for adolescents with acquired brain injury.

    PubMed

    Kim, Soo Ji; Shin, Yoon-Kyum; Yoo, Ga Eul; Chong, Hyun Ju; Cho, Sung-Rae

    2016-12-01

    The effects of rhythmic auditory stimulation (RAS) on gait in adolescents with acquired brain injury (ABI) were investigated. A total of 14 adolescents with ABI were initially recruited, and 12 were included in the final analysis (n = 6 each). They were randomly assigned to the experimental (RAS) or the control (conventional gait training) groups. The experimental group received gait training with RAS three times a week for 4 weeks. For both groups, spatiotemporal parameters and kinematic data, such as dynamic motions of joints on three-dimensional planes during a gait cycle and the range of motion in each joint, were collected. Significant group differences in pre-post changes were observed in cadence, walking velocity, and step time, indicating that there were greater improvements in those parameters in the RAS group compared with the control group. Significant increases in hip and knee motions in the sagittal plane were also observed in the RAS group. The changes in kinematic data significantly differed between groups, particularly from terminal stance to mid-swing phase. An increase of both spatiotemporal parameters and corresponding kinematic changes of hip and knee joints after RAS protocol indicates that the use of rhythmic cueing may change gait patterns in adolescents with ABI. © 2016 The Authors. Annals of the New York Academy of Sciences published by Wiley Periodicals, Inc. on behalf of New York Academy of Sciences.

  8. Relationships between Isometric Muscle Strength, Gait Parameters, and Gross Motor Function Measure in Patients with Cerebral Palsy

    PubMed Central

    Shin, Hyung-Ik; Sung, Ki Hyuk; Chung, Chin Youb; Lee, Kyoung Min; Lee, Seung Yeol; Lee, In Hyeok

    2016-01-01

    Purpose This study investigated the correlation between isometric muscle strength, gross motor function, and gait parameters in patients with spastic cerebral palsy and to find which muscle groups play an important role for gait pattern in a flexed knee gait. Materials and Methods Twenty-four ambulatory patients (mean age, 10.0 years) with spastic cerebral palsy who were scheduled for single event multilevel surgery, including distal hamstring lengthening, were included. Preoperatively, peak isometric muscle strength was measured for the hip flexor, hip extensor, knee flexor, and knee extensor muscle groups using a handheld dynamometer, and three-dimensional (3D) gait analysis and gross motor function measure (GMFM) scoring were also performed. Correlations between peak isometric strength and GMFM, gait kinematics, and gait kinetics were analyzed. Results Peak isometric muscle strength of all muscle groups was not related to the GMFM score and the gross motor function classification system level. Peak isometric strength of the hip extensor and knee extensor was significantly correlated with the mean pelvic tilt (r=-0.588, p=0.003 and r=-0.436, p=0.033) and maximum pelvic obliquity (r=-0.450, p=0.031 and r=-0.419, p=0.041). There were significant correlations between peak isometric strength of the knee extensor and peak knee extensor moment in early stance (r=0.467, p=0.021) and in terminal stance (r=0.416, p=0.043). Conclusion There is no correlation between muscle strength and gross motor function. However, this study showed that muscle strength, especially of the extensor muscle group of the hip and knee joints, might play a critical role in gait by stabilizing pelvic motion and decreasing energy consumption in a flexed knee gait. PMID:26632404

  9. Does robot-assisted gait training ameliorate gait abnormalities in multiple sclerosis? A pilot randomized-control trial.

    PubMed

    Straudi, S; Benedetti, M G; Venturini, E; Manca, M; Foti, C; Basaglia, N

    2013-01-01

    Gait disorders are common in multiple sclerosis (MS) and lead to a progressive reduction of function and quality of life. Test the effects of robot-assisted gait rehabilitation in MS subjects through a pilot randomized-controlled study. We enrolled MS subjects with Expanded Disability Status Scale scores within 4.5-6.5. The experimental group received 12 robot-assisted gait training sessions over 6 weeks. The control group received the same amount of conventional physiotherapy. Outcomes measures were both biomechanical assessment of gait, including kinematics and spatio-temporal parameters, and clinical test of walking endurance (six-minute walk test) and mobility (Up and Go Test). 16 subjects (n = 8 experimental group, n = 8 control group) were included in the final analysis. At baseline the two groups were similar in all variables, except for step length. Data showed walking endurance, as well as spatio-temporal gait parameters improvements after robot-assisted gait training. Pelvic antiversion and reduced hip extension during terminal stance ameliorated after aforementioned intervention. Robot-assisted gait training seems to be effective in increasing walking competency in MS subjects. Moreover, it could be helpful in restoring the kinematic of the hip and pelvis.

  10. Evaluation of the relationship between the static measurement of transverse arch flexibility of the forefoot and gait parameters in healthy subjects

    PubMed Central

    Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu

    2017-01-01

    [Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study’s findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait. PMID:28356622

  11. Evaluation of the relationship between the static measurement of transverse arch flexibility of the forefoot and gait parameters in healthy subjects.

    PubMed

    Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu

    2017-03-01

    [Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study's findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait.

  12. The influence of the Re-Link Trainer on gait symmetry in healthy adults.

    PubMed

    Ward, Sarah; Wiedemann, Lukas; Stinear, Cathy; Stinear, James; McDaid, Andrew

    2017-07-01

    Walking function post-stroke is characterized by asymmetries in gait cycle parameters and joint kinematics. The Re-Link Trainer is designed to provide kinematic constraint to the paretic lower limb, to guide a physiologically normal and symmetrical gait pattern. The purpose of this pilot study was to assess the immediate influence of the Re-Link Trainer on measures of gait symmetry in healthy adults. Participants demonstrated a significantly lower cadence and a 62% reduction in walking speed in the Re-Link Trainer compared to normal walking. The step length ratio had a significant increase from 1.0 during normal walking to 2.5 when walking in the Re-Link Trainer. The results from this pilot study suggest in its current iteration the Re-Link Trainer imposes an asymmetrical constraint on lower limb kinematics.

  13. Different horse's paces during hippotherapy on spatio-temporal parameters of gait in children with bilateral spastic cerebral palsy: A feasibility study.

    PubMed

    Antunes, Fabiane Nunes; Pinho, Alexandre Severo do; Kleiner, Ana Francisca Rozin; Salazar, Ana Paula; Eltz, Giovana Duarte; de Oliveira Junior, Alcyr Alves; Cechetti, Fernanda; Galli, Manuela; Pagnussat, Aline Souza

    2016-12-01

    Hippotherapy is often carried out for the rehabilitation of children with Cerebral Palsy (CP), with the horse riding at a walking pace. This study aimed to explore the immediate effects of a hippotherapy protocol using a walk-trot pace on spatio-temporal gait parameters and muscle tone in children with Bilateral Spastic CP (BS-CP). Ten children diagnosed with BS-CP and 10 healthy aged-matched children (reference group) took part in this study. The children with BS-CP underwent two sessions of hippotherapy for one week of washout between them. Two protocols (lasting 30min) were applied on separate days: Protocol 1: the horse's pace was a walking pace; and Protocol 2: the horse's pace was a walk-trot pace. Children from the reference group were not subjected to treatment. A wireless inertial measurement unit measured gait spatio-temporal parameters before and after each session. The Modified Ashworth Scale was applied for muscle tone measurement of hip adductors. The participants underwent the gait assessment on a path with surface irregularities (ecological context). The comparisons between BS-CP and the reference group found differences in all spatio-temporal parameters, except for gait velocity. Within-group analysis of children with BS-CP showed that the swing phase did not change after the walk pace and after the walk-trot pace. The percentage of rolling phase and double support improved after the walk-trot. The spasticity of the hip adductors was significantly reduced as an immediate result of both protocols, but this decrease was more evident after the walk-trot. The walk-trot protocol is feasible and is able to induce an immediate effect that improves the gait spatio-temporal parameters and the hip adductors spasticity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Prospective dynamic functional evaluation of gait and spinal balance following spinal fusion in adolescent idiopathic scoliosis.

    PubMed

    Lenke, L G; Engsberg, J R; Ross, S A; Reitenbach, A; Blanke, K; Bridwell, K H

    2001-07-15

    Prospective evaluation of gait and spinal-pelvic balance parameters in patients with adolescent idiopathic scoliosis undergoing a spinal fusion. To evaluate changes in gait and three-dimensional alignment and balance of the spine relative to the pelvis as a consequence of spinal fusion. Preoperative and postoperative spinal radiographs have been the major forms of outcome analysis of adolescent idiopathic scoliosis fusions. The use of optoelectronic analysis for posture and gait has gained acceptance recently. However, there is a paucity of data quantifying, comparing, and correlating structural and functional changes in patients undergoing scoliosis fusion surgery including upright posture and gait. Thirty patients with adolescent idiopathic scoliosis undergoing an instrumented spinal fusion were prospectively evaluated. Coronal and sagittal vertical alignment was evaluated on radiographs (CVA-R, SVA-R), during upright posture (CVA-P and SVA-P), and during gait (CVA-G, SVA-G). Transverse plane alignment was evaluated by the acromion-pelvis angle during gait. Gait speed was significantly decreased (P < 0.05) between preoperative (129 +/- 16 cm/sec) and 2-year postoperative (119 +/- 16 cm/sec) testing sessions. Decreasing gait speed was the result of significantly reduced cadence and decreased stride length. There were no significant differences for lower extremity kinematics over the entire gait cycle. Spinal-pelvic balance parameters showed significant improvement in mean CVA-R, CVA-G (P < 0.05), then unchanged CVA-P at 2 years postoperation. CVA-P was relatively unchanged while the mean CVA-G also showed significant improvement from preoperation (2.2 +/- 2.4 cm) to 2 years postoperation (1.3 +/- 1.3 cm)(P < 0.05). The mean SVA-R, SVA-P, and SVA-G were unchanged at 2 years postoperation (P > 0.05). The acromion-pelvis angle during gait at maximum shoulder rotation was statistically improved at 1 year (P = 0.002) and 2 years (P = 0.001) after surgery. Importantly

  15. Gait Analysis Methods for Rodent Models of Arthritic Disorders: Reviews and Recommendations

    PubMed Central

    Lakes, Emily H.; Allen, Kyle D.

    2016-01-01

    Gait analysis is a useful tool to understand behavioral changes in preclinical arthritis models. While observational scoring and spatiotemporal gait parameters are the most widely performed gait analyses in rodents, commercially available systems can now provide quantitative assessments of spatiotemporal patterns. However, inconsistencies remain between testing platforms, and laboratories often select different gait pattern descriptors to report in the literature. Rodent gait can also be described through kinetic and kinematic analyses, but systems to analyze rodent kinetics and kinematics are typically custom made and often require sensitive, custom equipment. While the use of rodent gait analysis rapidly expands, it is important to remember that, while rodent gait analysis is a relatively modern behavioral assay, the study of quadrupedal gait is not new. Nearly all gait parameters are correlated, and a collection of gait parameters is needed to understand a compensatory gait pattern used by the animal. As such, a change in a single gait parameter is unlikely to tell the full biomechanical story; and to effectively use gait analysis, one must consider how multiple different parameters contribute to an altered gait pattern. The goal of this article is to review rodent gait analysis techniques and provide recommendations on how to use these technologies in rodent arthritis models, including discussions on the strengths and limitations of observational scoring, spatiotemporal, kinetic, and kinematic measures. Recognizing rodent gait analysis is an evolving tool, we also provide technical recommendations we hope will improve the utility of these analyses in the future. PMID:26995111

  16. Acute effects of anesthetic lumbar spine injections on temporal spatial parameters of gait in individuals with chronic low back pain: A pilot study.

    PubMed

    Herndon, Carl L; Horodyski, MaryBeth; Vincent, Heather K

    2017-10-01

    This study examined whether epidural injection-induced anesthesia acutely and positively affected temporal spatial parameters of gait in patients with chronic low back pain (LBP) due to lumbar spinal stenosis. Twenty-five patients (61.7±13.6years) who were obtaining lumbar epidural injections for stenosis-related LBP participated. Oswestry Disability Index (ODI) scores, Medical Outcomes Short Form (SF-36) scores, 11-point Numerical pain rating (NRS pain ) scores, and temporal spatial parameters of walking gait were obtained prior to, and 11-point Numerical pain rating (NRS pain ) scores, and temporal spatial parameters of walking gait were obtained after the injection. Gait parameters were measured using an instrumented gait mat. Patients received transforaminal epidural injections in the L1-S1 vertebral range (1% lidocaine, corticosteroid) under fluoroscopic guidance. Patients with post-injection NRS pain ratings of "0" or values greater than "0" were stratified into two groups: 1) full pain relief, or 2) partial pain relief, respectively. Post-injection, 48% (N=12) of patients reported full pain relief. ODI scores were higher in patients with full pain relief (55.3±21.4 versus 33.7 12.8; p=0.008). Post-injection, stride length and step length variability were significantly improved in the patients with full pain relief compared to those with partial pain relief. Effect sizes between full and partial pain relief for walking velocity, step length, swing time, stride and step length variability were medium to large (Cohen's d>0.50). Patients with LBP can gain immediate gait improvements from complete pain relief from transforaminal epidural anesthetic injections for LBP, which could translate to better stability and lower fall risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Neuro-Mechanics of Recumbent Leg Cycling in Post-Acute Stroke Patients.

    PubMed

    Ambrosini, Emilia; De Marchis, Cristiano; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Monticone, Marco; Schmid, Maurizio; D'Alessio, Tommaso; Conforto, Silvia; Ferrante, Simona

    2016-11-01

    Cycling training is strongly applied in post-stroke rehabilitation, but how its modular control is altered soon after stroke has been not analyzed yet. EMG signals from 9 leg muscles and pedal forces were measured bilaterally during recumbent pedaling in 16 post-acute stroke patients and 12 age-matched healthy controls. Patients were asked to walk over a GaitRite mat and standard gait parameters were computed. Four muscle synergies were extracted through nonnegative matrix factorization in healthy subjects and patients unaffected legs. Two to four synergies were identified in the affected sides and the number of synergies significantly correlated with the Motricity Index (Spearman's coefficient = 0.521). The reduced coordination complexity resulted in a reduced biomechanical performance, with the two-module sub-group showing the lowest work production and mechanical effectiveness in the affected side. These patients also exhibited locomotor impairments (reduced gait speed, asymmetrical stance time, prolonged double support time). Significant correlations were found between cycling-based metrics and gait parameters, suggesting that neuro-mechanical quantities of pedaling can inform on walking dysfunctions. Our findings support the use of pedaling as a rehabilitation method and an assessment tool after stroke, mainly in the early phase, when patients can be unable to perform a safe and active gait training.

  18. Effects of wide step walking on swing phase hip muscle forces and spatio-temporal gait parameters.

    PubMed

    Bajelan, Soheil; Nagano, Hanatsu; Sparrow, Tony; Begg, Rezaul K

    2017-07-01

    Human walking can be viewed essentially as a continuum of anterior balance loss followed by a step that re-stabilizes balance. To secure balance an extended base of support can be assistive but healthy young adults tend to walk with relatively narrower steps compared to vulnerable populations (e.g. older adults and patients). It was, therefore, hypothesized that wide step walking may enhance dynamic balance at the cost of disturbed optimum coupling of muscle functions, leading to additional muscle work and associated reduction of gait economy. Young healthy adults may select relatively narrow steps for a more efficient gait. The current study focused on the effects of wide step walking on hip abductor and adductor muscles and spatio-temporal gait parameters. To this end, lower body kinematic data and ground reaction forces were obtained using an Optotrak motion capture system and AMTI force plates, respectively, while AnyBody software was employed for muscle force simulation. A single step of four healthy young male adults was captured during preferred walking and wide step walking. Based on preferred walking data, two parallel lines were drawn on the walkway to indicate 50% larger step width and participants targeted the lines with their heels as they walked. In addition to step width that defined walking conditions, other spatio-temporal gait parameters including step length, double support time and single support time were obtained. Average hip muscle forces during swing were modeled. Results showed that in wide step walking step length increased, Gluteus Minimus muscles were more active while Gracilis and Adductor Longus revealed considerably reduced forces. In conclusion, greater use of abductors and loss of adductor forces were found in wide step walking. Further validation is needed in future studies involving older adults and other pathological populations.

  19. Information presentation through a head-worn display (“smart glasses”) has a smaller influence on the temporal structure of gait variability during dual-task gait compared to handheld displays (paper-based system and smartphone)

    PubMed Central

    Sedighi, Alireza; Ulman, Sophia M.

    2018-01-01

    The need to complete multiple tasks concurrently is a common occurrence both daily life and in occupational activities, which can often include simultaneous cognitive and physical demands. As one example, there is increasing availability of head-worn display technologies that can be employed when a user is mobile (e.g., while walking). This new method of information presentation may, however, introduce risks of adverse outcomes such as a decrement to gait performance. The goal of this study was thus to quantify the effects of a head-worn display (i.e., smart glasses) on motor variability during gait and to compare these effects with those of other common information displays (i.e., smartphone and paper-based system). Twenty participants completed four walking conditions, as a single task and in three dual-task conditions (three information displays). In the dual-task conditions, the information display was used to present several cognitive tasks. Three different measures were used to quantify variability in gait parameters for each walking condition (using the cycle-to-cycle standard deviation, sample entropy, and the “goal-equivalent manifold” approach). Our results indicated that participants used less adaptable gait strategies in dual-task walking using the paper-based system and smartphone conditions compared with single-task walking. Gait performance, however, was less affected during dual-task walking with the smart glasses. We conclude that the risk of an adverse gait event (e.g., a fall) in head-down walking conditions (i.e., the paper-based system and smartphone conditions) were higher than in single-task walking, and that head-worn displays might help reduce the risk of such events during dual-task gait conditions. PMID:29630614

  20. Quantifying gait deviations in individuals with rheumatoid arthritis using the Gait Deviation Index.

    PubMed

    Esbjörnsson, A-C; Rozumalski, A; Iversen, M D; Schwartz, M H; Wretenberg, P; Broström, E W

    2014-01-01

    In this study we evaluated the usability of the Gait Deviation Index (GDI), an index that summarizes the amount of deviation in movement from a standard norm, in adults with rheumatoid arthritis (RA). The aims of the study were to evaluate the ability of the GDI to identify gait deviations, assess inter-trial repeatability, and examine the relationship between the GDI and walking speed, physical disability, and pain. Sixty-three adults with RA and 59 adults with typical gait patterns were included in this retrospective case-control study. Following a three-dimensional gait analysis (3DGA), representative gait cycles were selected and GDI scores calculated. To evaluate the effect of walking speed, GDI scores were calculated using both a free-speed and a speed-matched reference set. Physical disability was assessed using the Health Assessment Questionnaire (HAQ) and subjects rated their pain during walking. Adults with RA had significantly increased gait deviations compared to healthy individuals, as shown by lower GDI scores [87.9 (SD = 8.7) vs. 99.4 (SD = 8.3), p < 0.001]. This difference was also seen when adjusting for walking speed [91.7 (SD = 9.0) vs. 99.9 (SD = 8.6), p < 0.001]. It was estimated that a change of ≥ 5 GDI units was required to account for natural variation in gait. There was no evident relationship between GDI and low/high RA-related physical disability and pain. The GDI seems to useful for identifying and summarizing gait deviations in individuals with RA. Thus, we consider that the GDI provides an overall measure of gait deviation that may reflect lower extremity pathology and may help clinicians to understand the impact of RA on gait dynamics.

  1. Gait patterns comparison of children with Duchenne muscular dystrophy to those of control subjects considering the effect of gait velocity.

    PubMed

    Gaudreault, Nathaly; Gravel, Denis; Nadeau, Sylvie; Houde, Sylvie; Gagnon, Denis

    2010-07-01

    3D analysis of the gait of children with Duchenne muscular dystrophy (DMD) was the topic of only a few studies and none of these considered the effect of gait velocity on the gait parameters of children with DMD. Gait parameters of 11 children with DMD were compared to those of 14 control children while considering the effect of gait velocity using 3D biomechanical analysis. Kinematic and kinetic gait parameters were measured using an Optotrak motion analysis system and AMTI force plates embedded in the floor. The data profiles of children with DMD walking at natural gait velocity were compared to those of the control children who walked at both natural and slow gait velocities. When both groups walked at similar velocity, children with DMD had higher cadence and shorter step length. They demonstrated a lower hip extension moment as well as a minimal or absent knee extension moment. At the ankle, a dorsiflexion moment was absent at heel strike due to the anterior location of the center of pressure. The magnitude of the medio-lateral ground reaction force was higher in children with DMD. Despite this increase, the hip abductor moment was lower. Hip power generation was also observed at the mid-stance in DMD children. These results suggest that most of the modifications observed are strategies used by children with DMD to cope with possible muscle weakness in order to provide support, propulsion and balance of the body during gait. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Optics in gait analysis and anthropometry

    NASA Astrophysics Data System (ADS)

    Silva Moreno, Alejandra Alicia

    2013-11-01

    Since antiquity, human gait has been studied to understand human movement, the kind of gait, in some cases, can cause musculoskeletal disorders or other health problems; in addition, also from antiquity, anthropometry has been important for the design of human items such as workspaces, tools, garments, among others. Nowadays, thanks to the development of optics and electronics, more accurate studies of gait and anthropometry can be developed. This work will describe the most important parameters for gait analysis, anthropometry and the optical systems used.

  3. Higher heritabilities for gait components than for overall gait scores may improve mobility in ducks.

    PubMed

    Duggan, Brendan M; Rae, Anne M; Clements, Dylan N; Hocking, Paul M

    2017-05-02

    Genetic progress in selection for greater body mass and meat yield in poultry has been associated with an increase in gait problems which are detrimental to productivity and welfare. The incidence of suboptimal gait in breeding flocks is controlled through the use of a visual gait score, which is a subjective assessment of walking ability of each bird. The subjective nature of the visual gait score has led to concerns over its effectiveness in reducing the incidence of suboptimal gait in poultry through breeding. The aims of this study were to assess the reliability of the current visual gait scoring system in ducks and to develop a more objective method to select for better gait. Experienced gait scorers assessed short video clips of walking ducks to estimate the reliability of the current visual gait scoring system. Kendall's coefficients of concordance between and within observers were estimated at 0.49 and 0.75, respectively. In order to develop a more objective scoring system, gait components were visually scored on more than 4000 pedigreed Pekin ducks and genetic parameters were estimated for these components. Gait components, which are a more objective measure, had heritabilities that were as good as, or better than, those of the overall visual gait score. Measurement of gait components is simpler and therefore more objective than the standard visual gait score. The recording of gait components can potentially be automated, which may increase accuracy further and may improve heritability estimates. Genetic correlations were generally low, which suggests that it is possible to use gait components to select for an overall improvement in both economic traits and gait as part of a balanced breeding programme.

  4. Altered vision destabilizes gait in older persons.

    PubMed

    Helbostad, Jorunn L; Vereijken, Beatrix; Hesseberg, Karin; Sletvold, Olav

    2009-08-01

    This study assessed the effects of dim light and four experimentally induced changes in vision on gait speed and footfall and trunk parameters in older persons walking on level ground. Using a quasi-experimental design, gait characteristics were assessed in full light, dim light, and in dim light combined with manipulations resulting in reduced depth vision, double vision, blurred vision, and tunnel vision, respectively. A convenience sample of 24 home-dwelling older women and men (mean age 78.5 years, SD 3.4) with normal vision for their age and able to walk at least 10 m without assistance participated. Outcome measures were gait speed and spatial and temporal parameters of footfall and trunk acceleration, derived from an electronic gait mat and accelerometers. Dim light alone had no effect. Vision manipulations combined with dim light had effect on most footfall parameters but few trunk parameters. The largest effects were found regarding double and tunnel vision. Men increased and women decreased gait speed following manipulations (p=0.017), with gender differences also in stride velocity variability (p=0.017) and inter-stride medio-lateral trunk acceleration variability (p=0.014). Gender effects were related to differences in body height and physical functioning. Results indicate that visual problems lead to a more cautious and unstable gait pattern even under relatively simple conditions. This points to the importance of assessing vision in older persons and correcting visual impairments where possible.

  5. Gait performance and foot pressure distribution during wearable robot-assisted gait in elderly adults.

    PubMed

    Lee, Su-Hyun; Lee, Hwang-Jae; Chang, Won Hyuk; Choi, Byung-Ok; Lee, Jusuk; Kim, Jeonghun; Ryu, Gyu-Ha; Kim, Yun-Hee

    2017-11-28

    A robotic exoskeleton device is an intelligent system designed to improve gait performance and quality of life for the wearer. Robotic technology has developed rapidly in recent years, and several robot-assisted gait devices were developed to enhance gait function and activities of daily living in elderly adults and patients with gait disorders. In this study, we investigated the effects of the Gait-enhancing Mechatronic System (GEMS), a new wearable robotic hip-assist device developed by Samsung Electronics Co, Ltd., Korea, on gait performance and foot pressure distribution in elderly adults. Thirty elderly adults who had no neurological or musculoskeletal abnormalities affecting gait participated in this study. A three-dimensional (3D) motion capture system, surface electromyography and the F-Scan system were used to collect data on spatiotemporal gait parameters, muscle activity and foot pressure distribution under three conditions: free gait without robot assistance (FG), robot-assisted gait with zero torque (RAG-Z) and robot-assisted gait (RAG). We found increased gait speed, cadence, stride length and single support time in the RAG condition. Reduced rectus femoris and medial gastrocnemius muscle activity throughout the terminal stance phase and reduced effort of the medial gastrocnemius muscle throughout the pre-swing phase were also observed in the RAG condition. In addition, walking with the assistance of GEMS resulted in a significant increase in foot pressure distribution, specifically in maximum force and peak pressure of the total foot, medial masks, anterior masks and posterior masks. The results of the present study reveal that GEMS may present an alternative way of restoring age-related changes in gait such as gait instability with muscle weakness, reduced step force and lower foot pressure in elderly adults. In addition, GEMS improved gait performance by improving push-off power and walking speed and reducing muscle activity in the lower

  6. Biologically-variable rhythmic auditory cues are superior to isochronous cues in fostering natural gait variability in Parkinson's disease.

    PubMed

    Dotov, D G; Bayard, S; Cochen de Cock, V; Geny, C; Driss, V; Garrigue, G; Bardy, B; Dalla Bella, S

    2017-01-01

    Rhythmic auditory cueing improves certain gait symptoms of Parkinson's disease (PD). Cues are typically stimuli or beats with a fixed inter-beat interval. We show that isochronous cueing has an unwanted side-effect in that it exacerbates one of the motor symptoms characteristic of advanced PD. Whereas the parameters of the stride cycle of healthy walkers and early patients possess a persistent correlation in time, or long-range correlation (LRC), isochronous cueing renders stride-to-stride variability random. Random stride cycle variability is also associated with reduced gait stability and lack of flexibility. To investigate how to prevent patients from acquiring a random stride cycle pattern, we tested rhythmic cueing which mimics the properties of variability found in healthy gait (biological variability). PD patients (n=19) and age-matched healthy participants (n=19) walked with three rhythmic cueing stimuli: isochronous, with random variability, and with biological variability (LRC). Synchronization was not instructed. The persistent correlation in gait was preserved only with stimuli with biological variability, equally for patients and controls (p's<0.05). In contrast, cueing with isochronous or randomly varying inter-stimulus/beat intervals removed the LRC in the stride cycle. Notably, the individual's tendency to synchronize steps with beats determined the amount of negative effects of isochronous and random cues (p's<0.05) but not the positive effect of biological variability. Stimulus variability and patients' propensity to synchronize play a critical role in fostering healthier gait dynamics during cueing. The beneficial effects of biological variability provide useful guidelines for improving existing cueing treatments. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Influence of velocity on variability in gait kinematics: implications for recognition in forensic science.

    PubMed

    Yang, Sylvia X M; Larsen, Peter K; Alkjaer, Tine; Lynnerup, Niels; Simonsen, Erik B

    2014-09-01

    Closed circuit television (CCTV) footage is often available from crime scenes and may be used to compare perpetrators with suspects. Usually, the footage comprises incomplete gait cycles at different velocities, making gait pattern identification from crimes difficult. This study investigated the concurrence of joint angles throughout a gait cycle at three different velocities (3.0, 4.5, 6.0 km/h). Six datasets at each velocity were collected from 16 men. A variability range VR throughout the gait cycle at each velocity for each joint angle for each person was calculated. The joint angles at each velocity were compared pairwise, and whenever this showed values within the VR of this velocity, the case was positive. By adding the positives throughout the gait cycle, phases with high and low concurrences were located; peak concurrence was observed at mid-stance phase. Striving for the same velocity for the suspect and perpetrator is recommended. © 2014 American Academy of Forensic Sciences.

  8. The effects of aquatic trunk exercise on gait and muscle activity in stroke patients: a randomized controlled pilot study.

    PubMed

    Park, Byoung-Sun; Noh, Ji-Woong; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-11-01

    [Purpose] The purpose of this study was to investigate the relationship between muscle activity and gait function following aquatic trunk exercise in hemiplegic stroke patients. [Subjects and Methods] This study's participants included thirteen hemiplegic patients (ten males and three females). The aquatic therapy consisted of administering concentrative aquatic therapy for four weeks in a therapeutic pool. Gait parameters were measured using a gait analysis system adjusted to each subject's comfortable walking speed. Electromyographic signals were measured for the rectus abdominis, external abdominal oblique, transversus abdominis/internal-abdominal oblique, and erector spine of each patients. [Results] The pre- and post-training performances of the transversus abdominis/internal-abdominal oblique were compared statistically. There was no statistical difference between the patients' pre- and post-training values of maximal voluntary isometric contraction of the rectus abdominis, but the external abdominal oblique values tended to improve. Furthermore, gait factors improved significantly in terms of walking speeds, walking cycles, affected-side stance phases, affected-stride lengths, and stance-phase symmetry indices, respectively. [Conclusion] These results suggest that the trunk exercise during aquatic therapy may in part contribute to clinically relevant improvements in muscle activities and gait parameters.

  9. The effects of aquatic trunk exercise on gait and muscle activity in stroke patients: a randomized controlled pilot study

    PubMed Central

    Park, Byoung-Sun; Noh, Ji-Woong; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-01-01

    [Purpose] The purpose of this study was to investigate the relationship between muscle activity and gait function following aquatic trunk exercise in hemiplegic stroke patients. [Subjects and Methods] This study’s participants included thirteen hemiplegic patients (ten males and three females). The aquatic therapy consisted of administering concentrative aquatic therapy for four weeks in a therapeutic pool. Gait parameters were measured using a gait analysis system adjusted to each subject’s comfortable walking speed. Electromyographic signals were measured for the rectus abdominis, external abdominal oblique, transversus abdominis/internal-abdominal oblique, and erector spine of each patients. [Results] The pre- and post-training performances of the transversus abdominis/internal-abdominal oblique were compared statistically. There was no statistical difference between the patients’ pre- and post-training values of maximal voluntary isometric contraction of the rectus abdominis, but the external abdominal oblique values tended to improve. Furthermore, gait factors improved significantly in terms of walking speeds, walking cycles, affected-side stance phases, affected-stride lengths, and stance-phase symmetry indices, respectively. [Conclusion] These results suggest that the trunk exercise during aquatic therapy may in part contribute to clinically relevant improvements in muscle activities and gait parameters. PMID:26696736

  10. Research on gait-based human identification

    NASA Astrophysics Data System (ADS)

    Li, Youguo

    Gait recognition refers to automatic identification of individual based on his/her style of walking. This paper proposes a gait recognition method based on Continuous Hidden Markov Model with Mixture of Gaussians(G-CHMM). First, we initialize a Gaussian mix model for training image sequence with K-means algorithm, then train the HMM parameters using a Baum-Welch algorithm. These gait feature sequences can be trained and obtain a Continuous HMM for every person, therefore, the 7 key frames and the obtained HMM can represent each person's gait sequence. Finally, the recognition is achieved by Front algorithm. The experiments made on CASIA gait databases obtain comparatively high correction identification ratio and comparatively strong robustness for variety of bodily angle.

  11. Reliability and validity of gait analysis by android-based smartphone.

    PubMed

    Nishiguchi, Shu; Yamada, Minoru; Nagai, Koutatsu; Mori, Shuhei; Kajiwara, Yuu; Sonoda, Takuya; Yoshimura, Kazuya; Yoshitomi, Hiroyuki; Ito, Hiromu; Okamoto, Kazuya; Ito, Tatsuaki; Muto, Shinyo; Ishihara, Tatsuya; Aoyama, Tomoki

    2012-05-01

    Smartphones are very common devices in daily life that have a built-in tri-axial accelerometer. Similar to previously developed accelerometers, smartphones can be used to assess gait patterns. However, few gait analyses have been performed using smartphones, and their reliability and validity have not been evaluated yet. The purpose of this study was to evaluate the reliability and validity of a smartphone accelerometer. Thirty healthy young adults participated in this study. They walked 20 m at their preferred speeds, and their trunk accelerations were measured using a smartphone and a tri-axial accelerometer that was secured over the L3 spinous process. We developed a gait analysis application and installed it in the smartphone to measure the acceleration. After signal processing, we calculated the gait parameters of each measurement terminal: peak frequency (PF), root mean square (RMS), autocorrelation peak (AC), and coefficient of variance (CV) of the acceleration peak intervals. Remarkable consistency was observed in the test-retest reliability of all the gait parameter results obtained by the smartphone (p<0.001). All the gait parameter results obtained by the smartphone showed statistically significant and considerable correlations with the same parameter results obtained by the tri-axial accelerometer (PF r=0.99, RMS r=0.89, AC r=0.85, CV r=0.82; p<0.01). Our study indicates that the smartphone with gait analysis application used in this study has the capacity to quantify gait parameters with a degree of accuracy that is comparable to that of the tri-axial accelerometer.

  12. The value of the NDT-Bobath method in post-stroke gait training.

    PubMed

    Mikołajewska, Emilia

    2013-01-01

    Stroke is perceived a major cause of disability, including gait disorders. Looking for more effective methods of gait reeducation in post-stroke survivors is one of the most important issues in contemporary neurorehabilitation. Following a stroke, patients suffer from gait disorders. The aim of this paper is to present the outcomes of a study of post-stroke gait reeducation using the NeuroDevelopmental Treatment-Bobath (NDT-Bobath) method. The research was conducted among 60 adult patients who had undergone ischemic stroke. These patients were treated using the NDT-Bobath method. These patients' gait reeducation was assessed using spatio-temporal gait parameters (gait velocity, cadence and stride length). Measurements of these parameters were conducted by the same therapist twice: on admission, and after the tenth session of gait reeducation. Among the 60 patients involved in the study, the results were as follows: in terms of gait velocity, recovery was observed in 39 cases (65%), in terms of cadence, recovery was observed in 39 cases (65%), in terms of stride length, recovery was observed in 50 cases (83.33%). Benefits were observed after short-term therapy, reflected by measurable statistically significant changes in the patients' gait parameters.

  13. Gait Implications of Visual Field Damage from Glaucoma.

    PubMed

    Mihailovic, Aleksandra; Swenor, Bonnielin K; Friedman, David S; West, Sheila K; Gitlin, Laura N; Ramulu, Pradeep Y

    2017-06-01

    To evaluate fall-relevant gait features in older glaucoma patients. The GAITRite Electronic Walkway was used to define fall-related gait parameters in 239 patients with suspected or manifest glaucoma under normal usual-pace walking conditions and while carrying a cup or tray. Multiple linear regression models assessed the association between gait parameters and integrated visual field (IVF) sensitivity after controlling for age, race, sex, medications, and comorbid illness. Under normal walking conditions, worse IVF sensitivity was associated with a wider base of support (β = 0.60 cm/5 dB IVF sensitivity decrement, 95% confidence interval [CI] = 0.12-1.09, P = 0.016). Worse IVF sensitivity was not associated with slower gait speed, shorter step or stride length, or greater left-right drift under normal walking conditions ( P > 0.05 for all), but was during cup and/or tray carrying conditions ( P < 0.05 for all). Worse IVF sensitivity was positively associated with greater stride-to-stride variability in step length, stride length, and stride velocity ( P < 0.005 for all). Inferior and superior IVF sensitivity demonstrated associations with each of the above gait parameters as well, though these associations were consistently similar to, or weaker than, the associations noted for overall IVF sensitivity. Glaucoma severity was associated with several gait parameters predictive of higher fall risk in prior studies, particularly measures of stride-to-stride variability. Gait may be useful in identifying glaucoma patients at higher risk of falls, and in designing and testing interventions to prevent falls in this high-risk group. These findings could serve to inform the development of the interventions for falls prevention in glaucoma patients.

  14. Crowd-Sourced Amputee Gait Data: A Feasibility Study Using YouTube Videos of Unilateral Trans-Femoral Gait.

    PubMed

    Gardiner, James; Gunarathne, Nuwan; Howard, David; Kenney, Laurence

    2016-01-01

    Collecting large datasets of amputee gait data is notoriously difficult. Additionally, collecting data on less prevalent amputations or on gait activities other than level walking and running on hard surfaces is rarely attempted. However, with the wealth of user-generated content on the Internet, the scope for collecting amputee gait data from alternative sources other than traditional gait labs is intriguing. Here we investigate the potential of YouTube videos to provide gait data on amputee walking. We use an example dataset of trans-femoral amputees level walking at self-selected speeds to collect temporal gait parameters and calculate gait asymmetry. We compare our YouTube data with typical literature values, and show that our methodology produces results that are highly comparable to data collected in a traditional manner. The similarity between the results of our novel methodology and literature values lends confidence to our technique. Nevertheless, clear challenges with the collection and interpretation of crowd-sourced gait data remain, including long term access to datasets, and a lack of validity and reliability studies in this area.

  15. Crowd-Sourced Amputee Gait Data: A Feasibility Study Using YouTube Videos of Unilateral Trans-Femoral Gait

    PubMed Central

    Gardiner, James; Gunarathne, Nuwan; Howard, David; Kenney, Laurence

    2016-01-01

    Collecting large datasets of amputee gait data is notoriously difficult. Additionally, collecting data on less prevalent amputations or on gait activities other than level walking and running on hard surfaces is rarely attempted. However, with the wealth of user-generated content on the Internet, the scope for collecting amputee gait data from alternative sources other than traditional gait labs is intriguing. Here we investigate the potential of YouTube videos to provide gait data on amputee walking. We use an example dataset of trans-femoral amputees level walking at self-selected speeds to collect temporal gait parameters and calculate gait asymmetry. We compare our YouTube data with typical literature values, and show that our methodology produces results that are highly comparable to data collected in a traditional manner. The similarity between the results of our novel methodology and literature values lends confidence to our technique. Nevertheless, clear challenges with the collection and interpretation of crowd-sourced gait data remain, including long term access to datasets, and a lack of validity and reliability studies in this area. PMID:27764226

  16. Reliability and validity of a smartphone-based assessment of gait parameters across walking speed and smartphone locations: Body, bag, belt, hand, and pocket.

    PubMed

    Silsupadol, Patima; Teja, Kunlanan; Lugade, Vipul

    2017-10-01

    The assessment of spatiotemporal gait parameters is a useful clinical indicator of health status. Unfortunately, most assessment tools require controlled laboratory environments which can be expensive and time consuming. As smartphones with embedded sensors are becoming ubiquitous, this technology can provide a cost-effective, easily deployable method for assessing gait. Therefore, the purpose of this study was to assess the reliability and validity of a smartphone-based accelerometer in quantifying spatiotemporal gait parameters when attached to the body or in a bag, belt, hand, and pocket. Thirty-four healthy adults were asked to walk at self-selected comfortable, slow, and fast speeds over a 10-m walkway while carrying a smartphone. Step length, step time, gait velocity, and cadence were computed from smartphone-based accelerometers and validated with GAITRite. Across all walking speeds, smartphone data had excellent reliability (ICC 2,1 ≥0.90) for the body and belt locations, with bag, hand, and pocket locations having good to excellent reliability (ICC 2,1 ≥0.69). Correlations between the smartphone-based and GAITRite-based systems were very high for the body (r=0.89, 0.98, 0.96, and 0.87 for step length, step time, gait velocity, and cadence, respectively). Similarly, Bland-Altman analysis demonstrated that the bias approached zero, particularly in the body, bag, and belt conditions under comfortable and fast speeds. Thus, smartphone-based assessments of gait are most valid when placed on the body, in a bag, or on a belt. The use of a smartphone to assess gait can provide relevant data to clinicians without encumbering the user and allow for data collection in the free-living environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Neuromuscular response of hip-spanning and low back muscles to medio-lateral foot center of pressure manipulation during gait.

    PubMed

    Solomonow-Avnon, Deborah; Levin, Daniel; Elboim-Gabyzon, Michal; Rozen, Nimrod; Peled, Eli; Wolf, Alon

    2016-06-01

    Footwear-generated medio-lateral foot center of pressure manipulation has been shown to have potential positive effects on gait parameters of hip osteoarthritis patients, ultimately reducing maximum joint reaction forces. The objective of this study was to investigate effects of medio-lateral foot center of pressure manipulation on muscle activity of hip-spanning and back muscles during gait in bilateral hip osteoarthritis patients. Foot center of pressure was shifted along the medio-lateral foot axis using a foot-worn biomechanical device allowing controlled center of pressure manipulation. Sixteen female bilateral hip osteoarthritis patients underwent electromyography analysis while walking in the device set to three parasagittal configurations: neutral (control), medial, and lateral. Seven hip-spanning muscles (Gluteus Medius, Gluteus Maximus, Tensor Fascia Latae, Rectus Femoris, Semitendinosis, Biceps Femoris, Adductor Magnus) and one back muscle (Erector Spinae) were analyzed. Magnitude and temporal parameters were calculated. The amplitude and temporal parameter varied significantly between foot center of pressure positions for 5 out of 8 muscles each for either the more or less symptomatic leg in at least one subphase of the gait cycle. Medio-lateral foot center of pressure manipulation significantly affects neuromuscular pattern of hip and back musculature during gait in female hip bilateral osteoarthritis patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Robot-assisted gait training in multiple sclerosis patients: a randomized trial.

    PubMed

    Schwartz, Isabella; Sajin, Anna; Moreh, Elior; Fisher, Iris; Neeb, Martin; Forest, Adina; Vaknin-Dembinsky, Adi; Karusis, Dimitrios; Meiner, Zeev

    2012-06-01

    Preservation of locomotor activity in multiple sclerosis (MS) patients is of utmost importance. Robotic-assisted body weight-supported treadmill training is a promising method to improve gait functions in neurologically impaired patients, although its effectiveness in MS patients is still unknown. To compare the effectiveness of robot-assisted gait training (RAGT) with that of conventional walking treatment (CWT) on gait and generalized functions in a group of stable MS patients. A prospective randomized controlled trial of 12 sessions of RAGT or CWT in MS patients of EDSS score 5-7. Primary outcome measures were gait parameters and the secondary outcomes were functional and quality of life parameters. All tests were performed at baseline, 3 and 6 months post-treatment by a blinded rater. Fifteen and 17 patients were randomly allocated to RAGT and CWT, respectively. Both groups were comparable at baseline in all parameters. As compared with baseline, although some gait parameters improved significantly following the treatment at each time point there was no difference between the groups. Both FIM and EDSS scores improved significantly post-treatment with no difference between the groups. At 6 months, most gait and functional parameters had returned to baseline. Robot-assisted gait training is feasible and safe and may be an effective additional therapeutic option in MS patients with severe walking disabilities.

  19. Cognitive and motor dual task gait training improve dual task gait performance after stroke - A randomized controlled pilot trial.

    PubMed

    Liu, Yan-Ci; Yang, Yea-Ru; Tsai, Yun-An; Wang, Ray-Yau

    2017-06-22

    This study investigated effects of cognitive and motor dual task gait training on dual task gait performance in stroke. Participants (n = 28) were randomly assigned to cognitive dual task gait training (CDTT), motor dual task gait training (MDTT), or conventional physical therapy (CPT) group. Participants in CDTT or MDTT group practiced the cognitive or motor tasks respectively during walking. Participants in CPT group received strengthening, balance, and gait training. The intervention was 30 min/session, 3 sessions/week for 4 weeks. Three test conditions to evaluate the training effects were single walking, walking while performing cognitive task (serial subtraction), and walking while performing motor task (tray-carrying). Parameters included gait speed, dual task cost of gait speed (DTC-speed), cadence, stride time, and stride length. After CDTT, cognitive-motor dual task gait performance (stride length and DTC-speed) was improved (p = 0.021; p = 0.015). After MDTT, motor dual task gait performance (gait speed, stride length, and DTC-speed) was improved (p = 0.008; p = 0.008; p = 0.008 respectively). It seems that CDTT improved cognitive dual task gait performance and MDTT improved motor dual task gait performance although such improvements did not reach significant group difference. Therefore, different types of dual task gait training can be adopted to enhance different dual task gait performance in stroke.

  20. Gait consistency over a 7-day interval in people with Parkinson's disease.

    PubMed

    Urquhart, D M; Morris, M E; Iansek, R

    1999-06-01

    To evaluate the consistency of temporal and spatial parameters of the walking pattern in subjects with idiopathic Parkinson's disease (PD) over a 7-day interval during the "on" phase of the levodopa medication cycle. Walking patterns were measured on a 12-meter walkway at the Kingston Gait Laboratory, Cheltenham, using a computerized stride analyzer. Sixteen subjects (7 women, 9 men) with PD recruited from the Movement Disorders Clinic at Kingston Centre. Speed of walking, stride length, cadence, and the percentage of the walking cycle spent in the double limb support phase of gait were measured, together with the level of disability as indexed by the modified Webster scale. Product-moment correlation coefficients and intraclass correlation coefficients (ICC 2,1) for repeat measures over a 7-day interval were high for speed (r = .90; ICC = .93), cadence (r = .90; ICC = .86), and stride length (r = 1.00; ICC = .97) and moderate for double limb support duration after removal of outliers (r = .75; ICC = .73); 95% confidence intervals for the change scores were within clinically acceptable limits for all variables. The mean modified Webster score was 11.4 on the first day and 10.1 7 days later. The gait pattern and level of disability in subjects with PD without severe motor fluctuations remained stable over a 1-week period when optimal medication prevailed.

  1. An elaborate data set on human gait and the effect of mechanical perturbations

    PubMed Central

    Hnat, Sandra K.; van den Bogert, Antonie J.

    2015-01-01

    Here we share a rich gait data set collected from fifteen subjects walking at three speeds on an instrumented treadmill. Each trial consists of 120 s of normal walking and 480 s of walking while being longitudinally perturbed during each stance phase with pseudo-random fluctuations in the speed of the treadmill belt. A total of approximately 1.5 h of normal walking (>5000 gait cycles) and 6 h of perturbed walking (>20,000 gait cycles) is included in the data set. We provide full body marker trajectories and ground reaction loads in addition to a presentation of processed data that includes gait events, 2D joint angles, angular rates, and joint torques along with the open source software used for the computations. The protocol is described in detail and supported with additional elaborate meta data for each trial. This data can likely be useful for validating or generating mathematical models that are capable of simulating normal periodic gait and non-periodic, perturbed gaits. PMID:25945311

  2. Gait Profile Score in multiple sclerosis patients with low disability.

    PubMed

    Morel, Eric; Allali, Gilles; Laidet, Magali; Assal, Frédéric; Lalive, Patrice H; Armand, Stéphane

    2017-01-01

    Gait abnormalities are subtle in multiple sclerosis (MS) patients with low disability and need to be better determined. As a biomechanical approach, the Gait Profile Score (GPS) is used to assess gait quality by combining nine gait kinematic variables in one single value. This study aims i) to establish if the GPS can detect gait impairments and ii) to compare GPS with discrete spatiotemporal and kinematic parameters in low-disabled MS patients. Thirty-four relapsing-remitting MS patients with an Expanded Disability Status Scale (EDSS) score ≤2 (mean age 36.32±8.72 years; 12 men, 22 women; mean EDSS 1.19±0.8) and twenty-two healthy controls (mean age 36.85±7.87 years; 6 men, 16 women) matched for age, weight, height, body mass index and gender underwent an instrumented gait analysis. No significant difference in GPS values and in spatiotemporal parameters was found between patients and controls. However patients showed a significant alteration at the ankle and pelvis level. GPS fails to identify gait abnormalities in low-disabled MS patients, although kinematic analysis revealed subtle gait alterations. Future studies should investigate other methods to assess gait impairments with a gait score in low-disabled MS patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. The Effects on Kinematics and Muscle Activity of Walking in a Robotic Gait Trainer During Zero-Force Control.

    PubMed

    van Asseldonk, Edwin H F; Veneman, Jan F; Ekkelenkamp, Ralf; Buurke, Jaap H; van der Helm, Frans C T; van der Kooij, Herman

    2008-08-01

    "Assist as needed" control algorithms promote activity of patients during robotic gait training. Implementing these requires a free walking mode of a device, as unassisted motions should not be hindered. The goal of this study was to assess the normality of walking in the free walking mode of the LOPES gait trainer, an 8 degrees-of-freedom lightweight impedance controlled exoskeleton. Kinematics, gait parameters and muscle activity of walking in a free walking mode in the device were compared with those of walking freely on a treadmill. Average values and variability of the spatio-temporal gait variables showed no or small (relative to cycle-to-cycle variability) changes and the kinematics showed a significant and relevant decrease in knee angle range only. Muscles involved in push off showed a small decrease, whereas muscles involved in acceleration and deceleration of the swing leg showed an increase of their activity. Timing of the activity was mainly unaffected. Most of the observed differences could be ascribed to the inertia of the exoskeleton. Overall, walking with the LOPES resembled free walking, although this required several adaptations in muscle activity. These adaptations are such that we expect that Assist as Needed training can be implemented in LOPES.

  4. An accelerometry-based comparison of 2 robotic assistive devices for treadmill training of gait.

    PubMed

    Regnaux, Jean-Philippe; Saremi, Kaveh; Marehbian, Jon; Bussel, Bernard; Dobkin, Bruce H

    2008-01-01

    Two commercial robotic devices, the Gait Trainer (GT) and the Lokomat (LOKO), assist task-oriented practice of walking. The gait patterns induced by these motor-driven devices have not been characterized and compared. A healthy participant chose the most comfortable gait pattern on each device and for treadmill (TM) walking at 1, 2 (maximum for the GT), and 3 km/h and over ground at similar speeds. A system of accelerometers on the thighs and feet allowed the calculation of spatiotemporal features and accelerations during the gait cycle. At the 1 and 2 km/h speed settings, single-limb stance times were prolonged on the devices compared with overground walking. Differences on the LOKO were decreased by adjusting the hip and knee angles and step length. At the 3 km/h setting, the LOKO approximated the participant's overground parameters. Irregular accelerations and decelerations from toe-off to heel contact were induced by the devices, especially at slower speeds. The LOKO and GT impose mechanical constraints that may alter leg accelerations-decelerations during stance and swing phases, as well as stance duration, especially at their slower speed settings, that are not found during TM and overground walking. The potential impact of these perturbations on training to improve gait needs further study.

  5. Spatiotemporal Gait Characteristics Associated with Cognitive Impairment: A Multicenter Cross-Sectional Study, the Intercontinental "Gait, cOgnitiOn & Decline" Initiative.

    PubMed

    Beauchet, Olivier; Blumen, Helena M; Callisaya, Michele L; De Cock, Anne-Marie; Kressig, Reto W; Srikanth, Velandai; Steinmetz, Jean-Paul; Verghese, Joe; Allali, Gilles

    2018-01-23

    The study aims to determine the spatiotemporal gait parameters and/or their combination(s) that best differentiate between cognitively healthy individuals (CHI), patients with mild cognitive impairment (MCI) and those with mild and moderate dementia, regardless of the etiology of cognitive impairment. A total of 2099 participants (1015 CHI, 478 patients with MCI, 331 patients with mild dementia and 275 with moderate dementia) were selected from the intercontinental "Gait, cOgnitiOn & Decline" (GOOD) initiative, which merged different databases from seven cross-sectional studies. Mean values and coefficients of variation (CoV) of spatiotemporal gait parameters were recorded during usual walking with the GAITRite® system. The severity of cognitive impairment was associated with worse performance on all gait parameters. Stride velocity had the strongest association with cognitive impairment, regardless of cognitive status. High mean value and CoV of stride length characterized moderate dementia, whereas increased CoV of stride time was specific to MCI status. The findings support the existence of specific cognitive impairment-related gait disturbances with differences related to stages of cognitive impairment, which may be used to screen individuals with cognitive impairment. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Terminology and forensic gait analysis.

    PubMed

    Birch, Ivan; Vernon, Wesley; Walker, Jeremy; Young, Maria

    2015-07-01

    The use of appropriate terminology is a fundamental aspect of forensic gait analysis. The language used in forensic gait analysis is an amalgam of that used in clinical practice, podiatric biomechanics and the wider field of biomechanics. The result can often be a lack of consistency in the language used, the definitions used and the clarity of the message given. Examples include the use of 'gait' and 'walking' as synonymous terms, confusion between 'step' and 'stride', the mixing of anatomical, positional and pathological descriptors, and inability to describe appropriately movements of major body segments such as the torso. The purpose of this paper is to share the well-established definitions of the fundamental parameters of gait, common to all professions, and advocate their use in forensic gait analysis to establish commonality. The paper provides guidance on the selection and use of appropriate terminology in the description of gait in the forensic context. This paper considers the established definitions of the terms commonly used, identifies those terms which have the potential to confuse readers, and suggests a framework of terminology which should be utilised in forensic gait analysis. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Effects of different heel-raise-lower exercise interventions on the strength of plantarflexion, balance, and gait parameters in stroke survivors.

    PubMed

    Lee, Seung-Mi; Cynn, Heon-Seock; Yoon, Tae-Lim; Lee, Ji-Hyun

    2017-09-01

    The objective of this study was to investigate the effects of Heel-Raise-Lower Exercise (HRLE) interventions on the strength of plantarflexion, balance, and gait parameters in people with stroke. Specifically, this study compared the two different HRLEs to identify whether heels raise-lower with forefoot on a block (HRB) is more effective or ineffective to enhance strength and functional capacities than heels raise-lower on a level floor (HRL) exercise in people with stroke. Repetitive heel raise-lower is a common exercise for improving the strength and power of ankle plantarflexors. It is a simple movement, requires no equipment, and can be performed at home. Each group of 10 people with stroke was given either HRB training or HRL training. The subjects performed the exercise 100 times per day, 5 days per week for 6 weeks. The strength of plantarflexors, static/dynamic balance, and gait parameters were measured using the manual muscle test (MMT), a Biodex Balance System (BBS) SD, and the GAITRite system. After 6 weeks of treatment, there were significant increases in the plantarflexors strength in both groups: by 34% in the HRB group and by 21% in the HRL group. Static and dynamic balance and gait speed also increased significantly in both groups. However, cadence, the paretic side single limb support period (SLSP), paretic side step length, and paretic side stride length significantly increased only in the HRB group. The HRB improved significantly the plantar flexor strength of the paretic side, gait speed, and cadence compared to the HRL.

  8. A perceptual map for gait symmetry quantification and pathology detection.

    PubMed

    Moevus, Antoine; Mignotte, Max; de Guise, Jacques A; Meunier, Jean

    2015-10-29

    The gait movement is an essential process of the human activity and the result of collaborative interactions between the neurological, articular and musculoskeletal systems, working efficiently together. This explains why gait analysis is important and increasingly used nowadays for the diagnosis of many different types (neurological, muscular, orthopedic, etc.) of diseases. This paper introduces a novel method to quickly visualize the different parts of the body related to an asymmetric movement in the human gait of a patient for daily clinical usage. The proposed gait analysis algorithm relies on the fact that the healthy walk has (temporally shift-invariant) symmetry properties in the coronal plane. The goal is to provide an inexpensive and easy-to-use method, exploiting an affordable consumer depth sensor, the Kinect, to measure the gait asymmetry and display results in a perceptual way. We propose a multi-dimensional scaling mapping using a temporally shift invariant distance, allowing us to efficiently visualize (in terms of perceptual color difference) the asymmetric body parts of the gait cycle of a subject. We also propose an index computed from this map and which quantifies locally and globally the degree of asymmetry. The proposed index is proved to be statistically significant and this new, inexpensive, marker-less, non-invasive, easy to set up, gait analysis system offers a readable and flexible tool for clinicians to analyze gait characteristics and to provide a fast diagnostic. This system, which estimates a perceptual color map providing a quick overview of asymmetry existing in the gait cycle of a subject, can be easily exploited for disease progression, recovery cues from post-operative surgery (e.g., to check the healing process or the effect of a treatment or a prosthesis) or might be used for other pathologies where gait asymmetry might be a symptom.

  9. Quantitative Gait Measurement With Pulse-Doppler Radar for Passive In-Home Gait Assessment

    PubMed Central

    Skubic, Marjorie; Rantz, Marilyn; Cuddihy, Paul E.

    2014-01-01

    In this paper, we propose a pulse-Doppler radar system for in-home gait assessment of older adults. A methodology has been developed to extract gait parameters including walking speed and step time using Doppler radar. The gait parameters have been validated with a Vicon motion capture system in the lab with 13 participants and 158 test runs. The study revealed that for an optimal step recognition and walking speed estimation, a dual radar set up with one radar placed at foot level and the other at torso level is necessary. An excellent absolute agreement with intraclass correlation coefficients of 0.97 was found for step time estimation with the foot level radar. For walking speed, although both radars show excellent consistency they all have a system offset compared to the ground truth due to walking direction with respect to the radar beam. The torso level radar has a better performance (9% offset on average) in the speed estimation compared to the foot level radar (13%–18% offset). Quantitative analysis has been performed to compute the angles causing the systematic error. These lab results demonstrate the capability of the system to be used as a daily gait assessment tool in home environments, useful for fall risk assessment and other health care applications. The system is currently being tested in an unstructured home environment. PMID:24771566

  10. Quantitative gait measurement with pulse-Doppler radar for passive in-home gait assessment.

    PubMed

    Wang, Fang; Skubic, Marjorie; Rantz, Marilyn; Cuddihy, Paul E

    2014-09-01

    In this paper, we propose a pulse-Doppler radar system for in-home gait assessment of older adults. A methodology has been developed to extract gait parameters including walking speed and step time using Doppler radar. The gait parameters have been validated with a Vicon motion capture system in the lab with 13 participants and 158 test runs. The study revealed that for an optimal step recognition and walking speed estimation, a dual radar set up with one radar placed at foot level and the other at torso level is necessary. An excellent absolute agreement with intraclass correlation coefficients of 0.97 was found for step time estimation with the foot level radar. For walking speed, although both radars show excellent consistency they all have a system offset compared to the ground truth due to walking direction with respect to the radar beam. The torso level radar has a better performance (9% offset on average) in the speed estimation compared to the foot level radar (13%-18% offset). Quantitative analysis has been performed to compute the angles causing the systematic error. These lab results demonstrate the capability of the system to be used as a daily gait assessment tool in home environments, useful for fall risk assessment and other health care applications. The system is currently being tested in an unstructured home environment.

  11. Real-time feedback to improve gait in children with cerebral palsy.

    PubMed

    van Gelder, Linda; Booth, Adam T C; van de Port, Ingrid; Buizer, Annemieke I; Harlaar, Jaap; van der Krogt, Marjolein M

    2017-02-01

    Real-time feedback may be useful for enhancing information gained from clinical gait analysis of children with cerebral palsy (CP). It may also be effective in functional gait training, however, it is not known if children with CP can adapt gait in response to real-time feedback of kinematic parameters. Sixteen children with cerebral palsy (age 6-16; GMFCS I-III), walking with a flexed-knee gait pattern, walked on an instrumented treadmill with virtual reality in three conditions: regular walking without feedback (NF), feedback on hip angle (FH) and feedback on knee angle (FK). Clinically relevant gait parameters were calculated and the gait profile score (GPS) was used as a measure of overall gait changes between conditions. All children, except one, were able to improve hip and/or knee extension during gait in response to feedback, with nine achieving a clinically relevant improvement. Peak hip extension improved significantly by 5.1±5.9° (NF: 8.9±12.8°, FH: 3.8±10.4°, p=0.01). Peak knee extension improved significantly by 7.7±7.1° (NF: 22.2±12.0°, FK: 14.5±12.7°, p<0.01). GPS did not change between conditions due to increased deviations in other gait parameters. Responders to feedback were shown to have worse initial gait as measured by GPS (p=0.005) and functional selectivity score (p=0.049). In conclusion, ambulatory children with CP show adaptability in gait and are able to respond to real-time feedback, resulting in significant and clinically relevant improvements in peak hip and knee extension. These findings show the potential of real-time feedback as a tool for functional gait training and advanced gait analysis in CP. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Accelerometry-based gait analysis, an additional objective approach to screen subjects at risk for falling.

    PubMed

    Senden, R; Savelberg, H H C M; Grimm, B; Heyligers, I C; Meijer, K

    2012-06-01

    This study investigated whether the Tinetti scale, as a subjective measure for fall risk, is associated with objectively measured gait characteristics. It is studied whether gait parameters are different for groups that are stratified for fall risk using the Tinetti scale. Moreover, the discriminative power of gait parameters to classify elderly according to the Tinetti scale is investigated. Gait of 50 elderly with a Tinneti>24 and 50 elderly with a Tinetti≤24 was analyzed using acceleration-based gait analysis. Validated algorithms were used to derive spatio-temporal gait parameters, harmonic ratio, inter-stride amplitude variability and root mean square (RMS) from the accelerometer data. Clear differences in gait were found between the groups. All gait parameters correlated with the Tinetti scale (r-range: 0.20-0.73). Only walking speed, step length and RMS showed moderate to strong correlations and high discriminative power to classify elderly according to the Tinetti scale. It is concluded that subtle gait changes that have previously been related to fall risk are not captured by the subjective assessment. It is therefore worthwhile to include objective gait assessment in fall risk screening. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Metabolic, Cardiopulmonary, and Gait Profiles of Recently Injured and Noninjured Runners

    PubMed Central

    Peng, Lucinda; Seay, Amanda N.; Montero, Cindy; Barnes, Leslie L.; Vincent, Kevin R.; Conrad, Bryan P.; Chen, Cong; Vincent, Heather K.

    2017-01-01

    Objective To examine whether runners recovering from a lower body musculoskeletal injury have different metabolic, cardiopulmonary, and gait responses compared with healthy runners. Design Cross-sectional study. Setting Research laboratory at an academic institution. Methods Healthy runners (n = 50) were compared with runners who were recently injured but had returned to running (n = 50). Both groups were participating in similar cross-training modalities such as swimming, weight training, biking, and yoga. Running gait was analyzed on a treadmill using 3-dimensional motion capture, and metabolic and cardiopulmonary measures were captured simultaneously with a portable metabolic analyzer. Main Outcome Measures Rate of oxygen consumption, heart rate, ventilation, carbohydrate and fat oxidation values, gait temporospatial parameters and range of motion measures (ROM) in the sagittal plane, energy expenditure, and vertical displacement of the body’s center of gravity (COG). Results The self-selected running speed was different between the injured and healthy runners (9.7 ± 1.1 km/h and 10.6 ± 1.1 km/h, respectively; P = .038). No significant group differences were noted in any metabolic or cardiopulmonary variable while running at the self-selected or standard speed (13.6 km/h). The vertical displacement of the COG was less in the injured group (8.4 ± 1.4 cm and 8.9 ± 1.4, respectively; P = .044). ROM about the right ankle in the sagittal plane at the self-selected running speed during the gait cycle was less in the injured runners compared with the healthy runners (P < .05). Conclusions Runners with a recent lower body injury who have returned to running have similar cardiopulmonary and metabolic responses to running as healthy runners at the self-selected and standard speeds; this finding may be due in part to participation in cross-training modes that preserve cardiopulmonary and metabolic adaptations. Injured runners may conserve motion by minimizing COG

  14. Gait Characteristic Analysis and Identification Based on the iPhone's Accelerometer and Gyrometer

    PubMed Central

    Sun, Bing; Wang, Yang; Banda, Jacob

    2014-01-01

    Gait identification is a valuable approach to identify humans at a distance. In this paper, gait characteristics are analyzed based on an iPhone's accelerometer and gyrometer, and a new approach is proposed for gait identification. Specifically, gait datasets are collected by the triaxial accelerometer and gyrometer embedded in an iPhone. Then, the datasets are processed to extract gait characteristic parameters which include gait frequency, symmetry coefficient, dynamic range and similarity coefficient of characteristic curves. Finally, a weighted voting scheme dependent upon the gait characteristic parameters is proposed for gait identification. Four experiments are implemented to validate the proposed scheme. The attitude and acceleration solutions are verified by simulation. Then the gait characteristics are analyzed by comparing two sets of actual data, and the performance of the weighted voting identification scheme is verified by 40 datasets of 10 subjects. PMID:25222034

  15. Quantitative Balance and Gait Measurement in Patients with Frontotemporal Dementia and Alzheimer Diseases: A Pilot Study.

    PubMed

    Velayutham, Selva Ganapathy; Chandra, Sadanandavalli Retnaswami; Bharath, Srikala; Shankar, Ravi Girikamatha

    2017-01-01

    Alzhiemers disease and Frontotemporal dementia are common neurodegenerative dementias with a wide prevalence. Falls are a common cause of morbidity in these patients. Identifying subclinical involvement of these parameters might serve as a tool in differential analysis of these distinct parameters involved in these conditions and also help in planning preventive strategies to prevent falls. Eight patients in age and gender matched patients in each group were compared with normal controls. Standardizes methods of gait and balance aseesment were done in all persons. Results revealed subclinical involvement of gait and balancesin all groups specially during divided attention. The parameters were significantly more affected in patients. Patients with AD and FTD had involement of over all ambulation index balance more affected in AD patients FTD patients showed step cycle, stride length abnormalities. There is balance and gait involvement in normal ageing as well as patients with AD and FTD. The pattern of involvement in AD correlates with WHERE pathway involvement and FTD with frontal subcortical circuits involvement. Identification the differential patterns of involvement in subclinical stage might help to differentiate normal ageing and the different types of cortical dementias. This could serve as an additional biomarker and also assist in initiating appropriate training methods to prevent future falls.

  16. A Bayesian framework for extracting human gait using strong prior knowledge.

    PubMed

    Zhou, Ziheng; Prügel-Bennett, Adam; Damper, Robert I

    2006-11-01

    Extracting full-body motion of walking people from monocular video sequences in complex, real-world environments is an important and difficult problem, going beyond simple tracking, whose satisfactory solution demands an appropriate balance between use of prior knowledge and learning from data. We propose a consistent Bayesian framework for introducing strong prior knowledge into a system for extracting human gait. In this work, the strong prior is built from a simple articulated model having both time-invariant (static) and time-variant (dynamic) parameters. The model is easily modified to cater to situations such as walkers wearing clothing that obscures the limbs. The statistics of the parameters are learned from high-quality (indoor laboratory) data and the Bayesian framework then allows us to "bootstrap" to accurate gait extraction on the noisy images typical of cluttered, outdoor scenes. To achieve automatic fitting, we use a hidden Markov model to detect the phases of images in a walking cycle. We demonstrate our approach on silhouettes extracted from fronto-parallel ("sideways on") sequences of walkers under both high-quality indoor and noisy outdoor conditions. As well as high-quality data with synthetic noise and occlusions added, we also test walkers with rucksacks, skirts, and trench coats. Results are quantified in terms of chamfer distance and average pixel error between automatically extracted body points and corresponding hand-labeled points. No one part of the system is novel in itself, but the overall framework makes it feasible to extract gait from very much poorer quality image sequences than hitherto. This is confirmed by comparing person identification by gait using our method and a well-established baseline recognition algorithm.

  17. Gait Recognition Using Wearable Motion Recording Sensors

    NASA Astrophysics Data System (ADS)

    Gafurov, Davrondzhon; Snekkenes, Einar

    2009-12-01

    This paper presents an alternative approach, where gait is collected by the sensors attached to the person's body. Such wearable sensors record motion (e.g. acceleration) of the body parts during walking. The recorded motion signals are then investigated for person recognition purposes. We analyzed acceleration signals from the foot, hip, pocket and arm. Applying various methods, the best EER obtained for foot-, pocket-, arm- and hip- based user authentication were 5%, 7%, 10% and 13%, respectively. Furthermore, we present the results of our analysis on security assessment of gait. Studying gait-based user authentication (in case of hip motion) under three attack scenarios, we revealed that a minimal effort mimicking does not help to improve the acceptance chances of impostors. However, impostors who know their closest person in the database or the genders of the users can be a threat to gait-based authentication. We also provide some new insights toward the uniqueness of gait in case of foot motion. In particular, we revealed the following: a sideway motion of the foot provides the most discrimination, compared to an up-down or forward-backward directions; and different segments of the gait cycle provide different level of discrimination.

  18. Gait Kinematics After Taping in Participants With Chronic Ankle Instability

    PubMed Central

    Chinn, Lisa; Dicharry, Jay; Hart, Joseph M.; Saliba, Susan; Wilder, Robert; Hertel, Jay

    2014-01-01

    Context: Chronic ankle instability is characterized by repetitive lateral ankle sprains. Prophylactic ankle taping is a common intervention used to reduce the risk of ankle sprains. However, little research has been conducted to evaluate the effect ankle taping has on gait kinematics. Objective: To investigate the effect of taping on ankle and knee kinematics during walking and jogging in participants with chronic ankle instability. Design: Controlled laboratory study. Setting: Motion analysis laboratory. Patients or Participants: A total of 15 individuals (8 men, 7 women; age = 26.9 ± 6.8 years, height = 171.7 ± 6.3 cm, mass = 73.5 ± 10.7 kg) with self-reported chronic ankle instability volunteered. They had an average of 5.3 ± 3.1 incidences of ankle sprain. Intervention(s): Participants walked and jogged in shoes on a treadmill while untaped and taped. The tape technique was a traditional preventive taping procedure. Conditions were randomized. Main Outcome Measure(s): Frontal-plane and sagittal-plane ankle and sagittal-plane knee kinematics were recorded throughout the entire gait cycle. Group means and 90% confidence intervals were calculated, plotted, and inspected for percentages of the gait cycle in which the confidence intervals did not overlap. Results: During walking, participants were less plantar flexed from 64% to 69% of the gait cycle (mean difference = 5.73° ± 0.54°) and less inverted from 51% to 61% (mean difference = 4.34° ± 0.65°) and 76% to 81% (mean difference = 5.55° ± 0.54°) of the gait cycle when taped. During jogging, participants were less dorsiflexed from 12% to 21% (mean difference = 4.91° ± 0.18°) and less inverted from 47% to 58% (mean difference = 6.52° ± 0.12°) of the gait cycle when taped. No sagittal-plane knee kinematic differences were found. Conclusions: In those with chronic ankle instability, taping resulted in a more neutral ankle position during walking and jogging in shoes on a treadmill. This change in

  19. Comparison of Gait Aspects According to FES Stimulation Position Applied to Stroke Patients

    PubMed Central

    Mun, Byeong-mu; Kim, Tae-ho; Lee, Jin-hwan; Lim, Jin-youg; Seo, Dong-kwon; Lee, Dong-jin

    2014-01-01

    [Purpose] This study sought to identify the gait aspects according to the FES stimulation position in stroke patients during gait training. [Subjects and Methods] To perform gait analysis, ten stroke patients were grouped based on 4 types of gait conditions: gait without FES stimulation (non-FES), gait with FES stimulation on the tibialis anterior (Ta), gait with FES stimulation on the tibialis anterior and quadriceps (TaQ), and gait with FES stimulation on the tibialis anterior and gluteus medius (TaGm). [Results] Based on repeated measures analysis of variance of measurements of gait aspects comprised of gait speed, gait cycle, and step length according to the FES stimulation position, the FES stimulation significantly affected gait aspects. [Conclusion] In conclusion, stimulating the tibialis anterior and quadriceps and stimulating the tibialis anterior and gluteus medius are much more effective than stimulating only the tibialis anterior during gait training in stroke patients using FES. PMID:24764634

  20. Children and adults minimise activated muscle volume by selecting gait parameters that balance gross mechanical power and work demands.

    PubMed

    Hubel, Tatjana Y; Usherwood, James R

    2015-09-01

    Terrestrial locomotion on legs is energetically expensive. Compared with cycling, or with locomotion in swimming or flying animals, walking and running are highly uneconomical. Legged gaits that minimise mechanical work have previously been identified and broadly match walking and running at appropriate speeds. Furthermore, the 'cost of muscle force' approaches are effective in relating locomotion kinetics to metabolic cost. However, few accounts have been made for why animals deviate from either work-minimising or muscle-force-minimising strategies. Also, there is no current mechanistic account for the scaling of locomotion kinetics with animal size and speed. Here, we report measurements of ground reaction forces in walking children and adult humans, and their stance durations during running. We find that many aspects of gait kinetics and kinematics scale with speed and size in a manner that is consistent with minimising muscle activation required for the more demanding between mechanical work and power: spreading the duration of muscle action reduces activation requirements for power, at the cost of greater work demands. Mechanical work is relatively more demanding for larger bipeds--adult humans--accounting for their symmetrical M-shaped vertical force traces in walking, and relatively brief stance durations in running compared with smaller bipeds--children. The gaits of small children, and the greater deviation of their mechanics from work-minimising strategies, may be understood as appropriate for their scale, not merely as immature, incompletely developed and energetically sub-optimal versions of adult gaits. © 2015. Published by The Company of Biologists Ltd.

  1. Underwater gait analysis in Parkinson's disease.

    PubMed

    Volpe, Daniele; Pavan, Davide; Morris, Meg; Guiotto, Annamaria; Iansek, Robert; Fortuna, Sofia; Frazzitta, Giuseppe; Sawacha, Zimi

    2017-02-01

    Although hydrotherapy is one of the physical therapies adopted to optimize gait rehabilitation in people with Parkinson disease, the quantitative measurement of gait-related outcomes has not been provided yet. This work aims to document the gait improvements in a group of parkinsonians after a hydrotherapy program through 2D and 3D underwater and on land gait analysis. Thirty-four parkinsonians and twenty-two controls were enrolled, divided into two different cohorts. In the first one, 2 groups of patients underwent underwater or land based walking training; controls underwent underwater walking training. Hence pre-treatment 2D underwater and on land gait analysis were performed, together with post-treatment on land gait analysis. Considering that current literature documented a reduced movement amplitude in parkinsonians across all lower limb joints in all movement planes, 3D underwater and on land gait analysis were performed on a second cohort of subjects (10 parkinsonians and 10 controls) who underwent underwater gait training. Baseline land 2D and 3D gait analysis in parkinsonians showed shorter stride length and slower speed than controls, in agreement with previous findings. Comparison between underwater and on land gait analysis showed reduction in stride length, cadence and speed on both parkinsonians and controls. Although patients who underwent underwater treatment exhibited significant changes on spatiotemporal parameters and sagittal plane lower limb kinematics, 3D gait analysis documented a significant (p<0.05) improvement in all movement planes. These data deserve attention for research directions promoting the optimal recovery and maintenance of walking ability. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  2. An intermittent control model of flexible human gait using a stable manifold of saddle-type unstable limit cycle dynamics

    PubMed Central

    Fu, Chunjiang; Suzuki, Yasuyuki; Kiyono, Ken; Morasso, Pietro; Nomura, Taishin

    2014-01-01

    Stability of human gait is the ability to maintain upright posture during walking against external perturbations. It is a complex process determined by a number of cross-related factors, including gait trajectory, joint impedance and neural control strategies. Here, we consider a control strategy that can achieve stable steady-state periodic gait while maintaining joint flexibility with the lowest possible joint impedance. To this end, we carried out a simulation study of a heel-toe footed biped model with hip, knee and ankle joints and a heavy head-arms-trunk element, working in the sagittal plane. For simplicity, the model assumes a periodic desired joint angle trajectory and joint torques generated by a set of feed-forward and proportional-derivative feedback controllers, whereby the joint impedance is parametrized by the feedback gains. We could show that a desired steady-state gait accompanied by the desired joint angle trajectory can be established as a stable limit cycle (LC) for the feedback controller with an appropriate set of large feedback gains. Moreover, as the feedback gains are decreased for lowering the joint stiffness, stability of the LC is lost only in a few dimensions, while leaving the remaining large number of dimensions quite stable: this means that the LC becomes saddle-type, with a low-dimensional unstable manifold and a high-dimensional stable manifold. Remarkably, the unstable manifold remains of low dimensionality even when the feedback gains are decreased far below the instability point. We then developed an intermittent neural feedback controller that is activated only for short periods of time at an optimal phase of each gait stride. We characterized the robustness of this design by showing that it can better stabilize the unstable LC with small feedback gains, leading to a flexible gait, and in particular we demonstrated that such an intermittent controller performs better if it drives the state point to the stable manifold, rather

  3. An intermittent control model of flexible human gait using a stable manifold of saddle-type unstable limit cycle dynamics.

    PubMed

    Fu, Chunjiang; Suzuki, Yasuyuki; Kiyono, Ken; Morasso, Pietro; Nomura, Taishin

    2014-12-06

    Stability of human gait is the ability to maintain upright posture during walking against external perturbations. It is a complex process determined by a number of cross-related factors, including gait trajectory, joint impedance and neural control strategies. Here, we consider a control strategy that can achieve stable steady-state periodic gait while maintaining joint flexibility with the lowest possible joint impedance. To this end, we carried out a simulation study of a heel-toe footed biped model with hip, knee and ankle joints and a heavy head-arms-trunk element, working in the sagittal plane. For simplicity, the model assumes a periodic desired joint angle trajectory and joint torques generated by a set of feed-forward and proportional-derivative feedback controllers, whereby the joint impedance is parametrized by the feedback gains. We could show that a desired steady-state gait accompanied by the desired joint angle trajectory can be established as a stable limit cycle (LC) for the feedback controller with an appropriate set of large feedback gains. Moreover, as the feedback gains are decreased for lowering the joint stiffness, stability of the LC is lost only in a few dimensions, while leaving the remaining large number of dimensions quite stable: this means that the LC becomes saddle-type, with a low-dimensional unstable manifold and a high-dimensional stable manifold. Remarkably, the unstable manifold remains of low dimensionality even when the feedback gains are decreased far below the instability point. We then developed an intermittent neural feedback controller that is activated only for short periods of time at an optimal phase of each gait stride. We characterized the robustness of this design by showing that it can better stabilize the unstable LC with small feedback gains, leading to a flexible gait, and in particular we demonstrated that such an intermittent controller performs better if it drives the state point to the stable manifold, rather

  4. The Required Coefficient of Friction for evaluating gait alterations in people with Multiple Sclerosis during gait.

    PubMed

    Pacifici, Ilaria; Galli, Manuela; Kleiner, Ana Francisca Rozin; Corona, Federica; Coghe, Giancarlo; Marongiu, Elisabetta; Loi, Andrea; Crisafulli, Antonio; Cocco, Eleonora; Marrosu, Maria Giovanna; Pau, Massimiliano

    2016-11-01

    Required Coefficient of Friction (RCOF) is one of the most critical gait parameters associated to the occurrence of slipping in individuals affected by neurological disorders characterized by balance impairments. This study aims to calculate RCOF in people with Multiple Sclerosis (MS) on the basis of three-dimensional Gait Analysis (GA) data. This study enrolls 22 people with MS (pwMS) who were characterized by an Expanded Disability Status Score in the range 1.5-6 and 10 healthy controls (HC). All participants underwent to three-dimensional GA from which we extracted kinematic and kinetic data (i.e. the Ground Reaction Forces, GRF, and joint moments and powers in the sagittal plane). RCOF was calculated as the ratio of the shear to normal GRF components during the stance phase of gait cycle, and normalized by the walking velocity. Thus, the following variables were extracted: first peak (named P1COF), valley (named V1COF), and second peak (named P2COF) in RCOF curve; also computating the maximum ankle dorsi-plantarflexion moment (MOMmax) and the maximum ankle joint power (PWRmax). Our data revealed that P2COF results are significantly lower in pwMS when compared to HC (p=0.043; Z=-2.025). In pwMS, the study found a moderate, positive correlation between V1COF and MOMmax (r=0.558; p<0.001) and a moderate, positive correlation between EDSS score and MOMmax (rho=0.622; p=0.001). While, in HC group, the study detected a moderate positive correlation between P1COF and MOM max (r=0.636; p=0.008). Friction during mid stance and push off phases is critically important to determine whether the frictional capabilities of foot/floor interface are sufficient to prevent slips in pwMS. The impaired ankle moment in MS group causes increased P2COF in comparison to HC, increasing the risk of slipping in the critical phase of transmission of the developed forces to kinematic chain. Also, the correlation analysis among RCOF values and kinetic variables describe the interplay between

  5. Plasticity of spinal centers in spinal cord injury patients: new concepts for gait evaluation and training.

    PubMed

    Scivoletto, Giorgio; Ivanenko, Yuri; Morganti, Barbara; Grasso, Renato; Zago, Mirka; Lacquaniti, Francesco; Ditunno, John; Molinari, Marco

    2007-01-01

    Recent data on spinal cord plasticity after spinal cord injury (SCI) were reviewed to analyze the influence of training on the neurophysiological organization of locomotor spinal circuits in SCI patients. In particular, the authors studied the relationship between central pattern generators (CPGs) and motor neuron pool activation during gait. An analysis of the relations between locomotor recovery and compensatory mechanisms focuses on the hierarchical organization of gait parameters and allows characterizing kinematic parameters that are highly stable during different gait conditions and in recovered gait after SCI. The importance of training characteristics and the use of robotic/automated devices in gait recovery is analyzed and discussed. The role of CPG in defining kinematic gait parameters is summarized, and spatio-temporal maps of EMG activity during gait are used to clarify the role of CPG plasticity in sustaining gait recovery.

  6. Immediate effects of a single session of robot-assisted gait training using Hybrid Assistive Limb (HAL) for cerebral palsy.

    PubMed

    Matsuda, Mayumi; Mataki, Yuki; Mutsuzaki, Hirotaka; Yoshikawa, Kenichi; Takahashi, Kazushi; Enomoto, Keiko; Sano, Kumiko; Mizukami, Masafumi; Tomita, Kazuhide; Ohguro, Haruka; Iwasaki, Nobuaki

    2018-02-01

    [Purpose] Robot-assisted gait training (RAGT) using Hybrid Assistive Limb (HAL, CYBERDYNE) was previously reported beneficial for stroke and spinal cord injury patients. Here, we investigate the immediate effect of a single session of RAGT using HAL on gait function for cerebral palsy (CP) patients. [Subjects and Methods] Twelve patients (average age: 16.2 ± 7.3 years) with CP received a single session of RAGT using HAL. Gait speed, step length, cadence, single-leg support per gait cycle, hip and knee joint angle in stance, and swing phase per gait cycle were assessed before, during, and immediately after HAL intervention. [Results] Compared to baseline values, single-leg support per gait cycle (64.5 ± 15.8% to 69.3 ± 12.1%), hip extension angle in mid-stance (149.2 ± 19.0° to 155.5 ± 20.1°), and knee extension angle in mid-stance (137.6 ± 20.2° to 143.1 ± 19.5°) were significantly increased immediately after intervention. Further, the knee flexion angle in mid-swing was significantly decreased immediately after treatment (112.0 ± 15.5° to 105.2 ± 17.1°). Hip flexion angle in mid-swing also decreased following intervention (137.2 ± 14.6° to 129.7 ± 16.6°), but not significantly. Conversely, gait speed, step length, and cadence were unchanged after intervention. [Conclusion] A single-time RAGT with HAL improved single-leg support per gait cycle and hip and knee joint angle during gait, therapeutically improving gait function in CP patients.

  7. Gait Parameter Adjustments for Walking on a Treadmill at Preferred, Slower, and Faster Speeds in Older Adults with Down Syndrome

    PubMed Central

    Smith, Beth A.; Kubo, Masayoshi; Ulrich, Beverly D.

    2012-01-01

    The combined effects of ligamentous laxity, hypotonia, and decrements associated with aging lead to stability-enhancing foot placement adaptations during routine overground walking at a younger age in adults with Down syndrome (DS) compared to their peers with typical development (TD). Our purpose here was to examine real-time adaptations in older adults with DS by testing their responses to walking on a treadmill at their preferred speed and at speeds slower and faster than preferred. We found that older adults with DS were able to adapt their gait to slower and faster than preferred treadmill speeds; however, they maintained their stability-enhancing foot placements at all speeds compared to their peers with TD. All adults adapted their gait patterns similarly in response to faster and slower than preferred treadmill-walking speeds. They increased stride frequency and stride length, maintained step width, and decreased percent stance as treadmill speed increased. Older adults with DS, however, adjusted their stride frequencies significantly less than their peers with TD. Our results show that older adults with DS have the capacity to adapt their gait parameters in response to different walking speeds while also supporting the need for intervention to increase gait stability. PMID:22693497

  8. Transfer effects of fall training on balance performance and spatiotemporal gait parameters in healthy community-dwelling older adults: a pilot study.

    PubMed

    Donath, Lars; Faude, Oliver; Bridenbaugh, Stephanie A; Roth, Ralf; Soltermann, Martin; Kressig, Reto W; Zahner, Lukas

    2014-07-01

    This study examined transfer effects of fall training on fear of falling (Falls Efficacy Scale-International [FES-I]), balance performance, and spatiotemporal gait characteristics in older adults. Eighteen community-dwelling older adults (ages 65-85) were randomly assigned to an intervention or control group. The intervention group completed 12 training sessions (60 min, 6 weeks). During pre- and posttesting, we measured FES-I, balance performance (double limb, closed eyes; single limb, open eyes; double limb, open eyes with motor-interfered task), and gait parameters (e.g., velocity; cadence; stride time, stride width, and stride length; variability of stride time and stride length) under single- and motor-interfered tasks. Dual tasks were applied to appraise improvements of cognitive processing during balance and gait. FES-I (p = .33) and postural sway did not significantly change (0.36 < p < .79). Trends toward significant interaction effects were found for step width during normal walking and stride length variability during the motor dual task (p = .05, ηp 2 = .22). Fall training did not sufficiently improve fear of falling, balance, or gait performance under single- or dual-task conditions in healthy older adults.

  9. Asymmetry in gait pattern following bicondylar tibial plateau fractures-A prospective one-year cohort study.

    PubMed

    Elsoe, Rasmus; Larsen, Peter

    2017-07-01

    Despite the high number of studies evaluating outcomes following tibial plateau fractures, the literature lacks studies including the objective assessment of gait pattern. The purpose of the present study was to evaluate asymmetry in gait patterns at 12 months after frame removal following ring fixation of a tibial plateau fracture. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns 12 months after frame removal measured with a pressure-sensitive mat. The mat registers footprints and present gait speed, cadence, as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. Twenty-three patients were included with a mean age of 54.4 years (32-78 years). Patients presented with a shorter step-length of the injured leg compared to the non-injured leg (asymmetry of 11.3%). Analysis of single-support showed shorter support time of the injured leg compared to the non-injured leg (asymmetry of 8.7%). Moreover, analysis of swing-time showed increased swing-time of the injured leg (asymmetry of 8.9%). Compared to a healthy reference population, increased asymmetry in all gait patterns was observed. The association between asymmetry and health-related quality of life (HRQOL) showed moderate associations (single-support: R=0.50, P=0.03; step-length: R=0.43, P=0.07; swing-time: R=0.46, P=0.05). Compared to a healthy reference population, gait asymmetry is common 12 months after frame removal in patients treated with external ring fixation following a tibial plateau fracture of the tibia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. IMU-Based Gait Recognition Using Convolutional Neural Networks and Multi-Sensor Fusion.

    PubMed

    Dehzangi, Omid; Taherisadr, Mojtaba; ChangalVala, Raghvendar

    2017-11-27

    The wide spread usage of wearable sensors such as in smart watches has provided continuous access to valuable user generated data such as human motion that could be used to identify an individual based on his/her motion patterns such as, gait. Several methods have been suggested to extract various heuristic and high-level features from gait motion data to identify discriminative gait signatures and distinguish the target individual from others. However, the manual and hand crafted feature extraction is error prone and subjective. Furthermore, the motion data collected from inertial sensors have complex structure and the detachment between manual feature extraction module and the predictive learning models might limit the generalization capabilities. In this paper, we propose a novel approach for human gait identification using time-frequency (TF) expansion of human gait cycles in order to capture joint 2 dimensional (2D) spectral and temporal patterns of gait cycles. Then, we design a deep convolutional neural network (DCNN) learning to extract discriminative features from the 2D expanded gait cycles and jointly optimize the identification model and the spectro-temporal features in a discriminative fashion. We collect raw motion data from five inertial sensors placed at the chest, lower-back, right hand wrist, right knee, and right ankle of each human subject synchronously in order to investigate the impact of sensor location on the gait identification performance. We then present two methods for early (input level) and late (decision score level) multi-sensor fusion to improve the gait identification generalization performance. We specifically propose the minimum error score fusion (MESF) method that discriminatively learns the linear fusion weights of individual DCNN scores at the decision level by minimizing the error rate on the training data in an iterative manner. 10 subjects participated in this study and hence, the problem is a 10-class identification task

  11. Adaptive changes in spatiotemporal gait characteristics in women during pregnancy.

    PubMed

    Błaszczyk, Janusz W; Opala-Berdzik, Agnieszka; Plewa, Michał

    2016-01-01

    Spatiotemporal gait cycle characteristics were assessed at early (P1), and late (P2) pregnancy, as well as at 2 months (PP1) and 6 months (PP2) postpartum. A substantial decrease in walking speed was observed throughout the pregnancy, with the slowest speed (1±0.2m/s) being during the third trimester. Walking at slower velocity resulted in complex adaptive adjustments to their spatiotemporal gait pattern, including a shorter step length and an increased duration of both their stance and double-support phases. Duration of the swing phase remained the least susceptible to changes. Habitual walking velocity (1.13±0.2m/s) and the optimal gait pattern were fully recovered 6 months after childbirth. Documented here adaptive changes in the preferred gait pattern seem to result mainly from the altered body anthropometry leading to temporary balance impairments. All the observed changes within stride cycle aimed to improve gait safety by focusing on its dynamic stability. The pregnant women preferred to walk at a slower velocity which allowed them to spend more time in double-support compared with their habitual pattern. Such changes provided pregnant women with a safer and more tentative ambulation that reduced the single-support period and, hence, the possibility of instability. As pregnancy progressed a significant increase in stance width and a decrease in step length was observed. Both factors allow also for gait stability improvement. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Quantitative Balance and Gait Measurement in Patients with Frontotemporal Dementia and Alzheimer Diseases: A Pilot Study

    PubMed Central

    Velayutham, Selva Ganapathy; Chandra, Sadanandavalli Retnaswami; Bharath, Srikala; Shankar, Ravi Girikamatha

    2017-01-01

    Introduction: Alzhiemers disease and Frontotemporal dementia are common neurodegenerative dementias with a wide prevalence. Falls are a common cause of morbidity in these patients. Identifying subclinical involvement of these parameters might serve as a tool in differential analysis of these distinct parameters involved in these conditions and also help in planning preventive strategies to prevent falls. Patients and Methods: Eight patients in age and gender matched patients in each group were compared with normal controls. Standardizes methods of gait and balance aseesment were done in all persons. Results: Results revealed subclinical involvement of gait and balancesin all groups specially during divided attention. The parameters were significantly more affected in patients. Patients with AD and FTD had involement of over all ambulation index balance more affected in AD patients FTD patients showed step cycle, stride length abnormalities. Discussion: There is balance and gait involvement in normal ageing as well as patients with AD and FTD. The pattern of involvement in AD correlates with WHERE pathway involvement and FTD with frontal subcortical circuits involvement. Conclusion: Identification the differential patterns of involvement in subclinical stage might help to differentiate normal ageing and the different types of cortical dementias. This could serve as an additional biomarker and also assist in initiating appropriate training methods to prevent future falls. PMID:28515555

  13. Gait Parameters and Functional Outcomes After Total Knee Arthroplasty Using Persona Knee System With Cruciate Retaining and Ultracongruent Knee Inserts.

    PubMed

    Rajgopal, Ashok; Aggarwal, Kalpana; Khurana, Anshika; Rao, Arun; Vasdev, Attique; Pandit, Hemant

    2017-01-01

    Total knee arthroplasty is a well-established treatment for managing end-stage symptomatic knee osteoarthritis. Currently, different designs of prostheses are available with majority ensuring similar clinical outcomes. Altered surface geometry is introduced to strive toward gaining superior outcomes. We aimed to investigate any differences in functional outcomes between 2 different polyethylene designs namely the Persona CR (cruciate retaining) and Persona UC (ultracongruent) tibial inserts (Zimmer-Biomet, Warsaw, IN). This prospective single blind, single-surgeon randomized controlled trial reports on 105 patients, (66 female and 39 male), who underwent simultaneous bilateral total knee arthroplasty using the Persona knee system (Zimmer-Biomet) UC inserts in one side and CR inserts in the contralateral side. By a blind assessor, at regular time intervals patients were assessed in terms of function and gait. The functional knee scoring scales used were the Western Ontario and McMaster Universities Osteoarthritis Index and Modified Knee Society Score. The gait parameters evaluated were foot pressure and step length. During the study period, no patient was lost to follow-up or underwent revision surgery for any cause. Western Ontario and McMaster Universities Osteoarthritis Index scores, Modified Knee Society Score, and knee range of motion of all 105 patients assessed preoperatively and postoperatively at 6 months, 1 year, and 2 years showed statistically better results (P < .05) for UC inserts. Gait analysis measuring foot pressures and step length, however, did not show any statistically significant differences at 2-year follow-up. Ultracongruent tibial inserts show significantly better functional outcomes as compared to CR inserts during a 2-year follow-up period. However, in this study these findings were not shown to be attributed to differences in gait parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Gait analysis following treadmill training with body weight support versus conventional physical therapy: a prospective randomized controlled single blind study.

    PubMed

    Lucareli, P R; Lima, M O; Lima, F P S; de Almeida, J G; Brech, G C; D'Andréa Greve, J M

    2011-09-01

    Single-blind randomized, controlled clinical study. To evaluate, using kinematic gait analysis, the results obtained from gait training on a treadmill with body weight support versus those obtained with conventional gait training and physiotherapy. Thirty patients with sequelae from traumatic incomplete spinal cord injuries at least 12 months earlier; patients were able to walk and were classified according to motor function as ASIA (American Spinal Injury Association) impairment scale C or D. Patients were divided randomly into two groups of 15 patients by the drawing of opaque envelopes: group A (weight support) and group B (conventional). After an initial assessment, both groups underwent 30 sessions of gait training. Sessions occurred twice a week, lasted for 30 min each and continued for four months. All of the patients were evaluated by a single blinded examiner using movement analysis to measure angular and linear kinematic gait parameters. Six patients (three from group A and three from group B) were excluded because they attended fewer than 85% of the training sessions. There were no statistically significant differences in intra-group comparisons among the spatial-temporal variables in group B. In group A, the following significant differences in the studied spatial-temporal variables were observed: increases in velocity, distance, cadence, step length, swing phase and gait cycle duration, in addition to a reduction in stance phase. There were also no significant differences in intra-group comparisons among the angular variables in group B. However, group A achieved significant improvements in maximum hip extension and plantar flexion during stance. Gait training with body weight support was more effective than conventional physiotherapy for improving the spatial-temporal and kinematic gait parameters among patients with incomplete spinal cord injuries.

  15. Gait Phase Estimation Based on Noncontact Capacitive Sensing and Adaptive Oscillators.

    PubMed

    Zheng, Enhao; Manca, Silvia; Yan, Tingfang; Parri, Andrea; Vitiello, Nicola; Wang, Qining

    2017-10-01

    This paper presents a novel strategy aiming to acquire an accurate and walking-speed-adaptive estimation of the gait phase through noncontact capacitive sensing and adaptive oscillators (AOs). The capacitive sensing system is designed with two sensing cuffs that can measure the leg muscle shape changes during walking. The system can be dressed above the clothes and free human skin from contacting to electrodes. In order to track the capacitance signals, the gait phase estimator is designed based on the AO dynamic system due to its ability of synchronizing with quasi-periodic signals. After the implementation of the whole system, we first evaluated the offline estimation performance by experiments with 12 healthy subjects walking on a treadmill with changing speeds. The strategy achieved an accurate and consistent gait phase estimation with only one channel of capacitance signal. The average root-mean-square errors in one stride were 0.19 rad (3.0% of one gait cycle) for constant walking speeds and 0.31 rad (4.9% of one gait cycle) for speed transitions even after the subjects rewore the sensing cuffs. We then validated our strategy in a real-time gait phase estimation task with three subjects walking with changing speeds. Our study indicates that the strategy based on capacitive sensing and AOs is a promising alternative for the control of exoskeleton/orthosis.

  16. Spatio-temporal gait disorder and gait fatigue index in a six-minute walk test in women with fibromyalgia.

    PubMed

    Heredia-Jimenez, Jose; Latorre-Roman, Pedro; Santos-Campos, Maria; Orantes-Gonzalez, Eva; Soto-Hermoso, Victor M

    2016-03-01

    Gait disorders in fibromyalgia patients affect several gait parameters and different muscle recruitment patterns. The aim of this study was to assess the gait differences observed during a six-minute walk test between fibromyalgia patients and healthy controls. Forty-eight women with fibromyalgia and 15 healthy women were evaluated. Fibromyalgia patients met the American College of Rheumatology criteria for fibromyalgia selected of an ambulatory care. Both patients and controls had a negative history of musculoskeletal disease, neurological disorders, and gait abnormalities. The 15 controls were healthy women matched to the patients in age, height and body weight. Spatio-temporal gait variables and the rate of perceived exertion during the six-minute walk test (all subjects) and Fibromyalgia Impact Questionnaire (fibromyalgia subjects) were evaluated. All walking sets on the GaitRITE were collected and the gait variables were selected at three stages during the six-minute walk test: two sets at the beginning, two sets at 3 min and two sets at the end of the test. In addition, the Fibromyalgia Impact Questionnaire was used for the fibromyalgia patients. Fibromyalgia patients showed a significant decrease in all spatio-temporal gait variables at each of the three stages and had a lower walk distance covered in the six-minute walk test and higher rate of perceived exertion. No correlations were found between the Fibromyalgia Impact Questionnaire and gait variables. The fibromyalgia and control subjects showed lower gait fatigue indices between the middle and last stages. Gait analysis during a six-minute walk test is a good tool to assess the fatigue and physical symptoms of patients with fibromyalgia. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Gait Deviations in Children With Osteogenesis Imperfecta Type I.

    PubMed

    Garman, Christina R; Graf, Adam; Krzak, Joseph; Caudill, Angela; Smith, Peter; Harris, Gerald

    2017-08-02

    Osteogenesis imperfecta (OI) is a congenital connective tissue disorder often characterized by orthopaedic complications that impact normal gait. As such, mobility is of particular interest in the OI population as it is associated with multiple aspects of participation and quality of life. The purpose of the current study was to identify and describe common gait deviations in a large sample of individuals with type I OI and speculate the etiology with a goal of improving function. Gait analysis was performed on 44 subjects with type I (11.7±3.08 y old) and 30 typically developing controls (9.54±3.1 y old ). Spatial temporal, kinematic, and kinetic gait data were calculated from the Vicon Plug-in-Gait Model. Musculoskeletal modeling of the muscle tendon lengths (MTL) was done in OpenSim 3.3 to evaluate the MTL of the gastrocnemius and gluteus maximus. The gait deviation index, a dimensionless parameter that evaluates the deviation of 9 kinematic gait parameters from a control database, was also calculated. Walking speed, single support time, stride, and step length were lower and double support time was higher in the OI group. The gait deviation index score was lower and external hip rotation angle was higher in the OI group. Peak hip flexor, knee extensor and ankle plantarflexor moments, and power generation at the ankle were lower in the OI group. MTL analysis revealed no significant length discrepancies between the OI group and the typically developing group. Together, these findings provide a comprehensive description of gait characteristics among a group of individuals with type I OI. Such data inform clinicians about specific gait deviations in this population allowing clinicians to recommend more focused interventions. Level III-case-control study.

  18. Statistical Parametric Mapping to Identify Differences between Consensus-Based Joint Patterns during Gait in Children with Cerebral Palsy.

    PubMed

    Nieuwenhuys, Angela; Papageorgiou, Eirini; Desloovere, Kaat; Molenaers, Guy; De Laet, Tinne

    2017-01-01

    Experts recently identified 49 joint motion patterns in children with cerebral palsy during a Delphi consensus study. Pattern definitions were therefore the result of subjective expert opinion. The present study aims to provide objective, quantitative data supporting the identification of these consensus-based patterns. To do so, statistical parametric mapping was used to compare the mean kinematic waveforms of 154 trials of typically developing children (n = 56) to the mean kinematic waveforms of 1719 trials of children with cerebral palsy (n = 356), which were classified following the classification rules of the Delphi study. Three hypotheses stated that: (a) joint motion patterns with 'no or minor gait deviations' (n = 11 patterns) do not differ significantly from the gait pattern of typically developing children; (b) all other pathological joint motion patterns (n = 38 patterns) differ from typically developing gait and the locations of difference within the gait cycle, highlighted by statistical parametric mapping, concur with the consensus-based classification rules. (c) all joint motion patterns at the level of each joint (n = 49 patterns) differ from each other during at least one phase of the gait cycle. Results showed that: (a) ten patterns with 'no or minor gait deviations' differed somewhat unexpectedly from typically developing gait, but these differences were generally small (≤3°); (b) all other joint motion patterns (n = 38) differed from typically developing gait and the significant locations within the gait cycle that were indicated by the statistical analyses, coincided well with the classification rules; (c) joint motion patterns at the level of each joint significantly differed from each other, apart from two sagittal plane pelvic patterns. In addition to these results, for several joints, statistical analyses indicated other significant areas during the gait cycle that were not included in the pattern definitions of the consensus study

  19. Immediate effects of a single session of robot-assisted gait training using Hybrid Assistive Limb (HAL) for cerebral palsy

    PubMed Central

    Matsuda, Mayumi; Mataki, Yuki; Mutsuzaki, Hirotaka; Yoshikawa, Kenichi; Takahashi, Kazushi; Enomoto, Keiko; Sano, Kumiko; Mizukami, Masafumi; Tomita, Kazuhide; Ohguro, Haruka; Iwasaki, Nobuaki

    2018-01-01

    [Purpose] Robot-assisted gait training (RAGT) using Hybrid Assistive Limb (HAL, CYBERDYNE) was previously reported beneficial for stroke and spinal cord injury patients. Here, we investigate the immediate effect of a single session of RAGT using HAL on gait function for cerebral palsy (CP) patients. [Subjects and Methods] Twelve patients (average age: 16.2 ± 7.3 years) with CP received a single session of RAGT using HAL. Gait speed, step length, cadence, single-leg support per gait cycle, hip and knee joint angle in stance, and swing phase per gait cycle were assessed before, during, and immediately after HAL intervention. [Results] Compared to baseline values, single-leg support per gait cycle (64.5 ± 15.8% to 69.3 ± 12.1%), hip extension angle in mid-stance (149.2 ± 19.0° to 155.5 ± 20.1°), and knee extension angle in mid-stance (137.6 ± 20.2° to 143.1 ± 19.5°) were significantly increased immediately after intervention. Further, the knee flexion angle in mid-swing was significantly decreased immediately after treatment (112.0 ± 15.5° to 105.2 ± 17.1°). Hip flexion angle in mid-swing also decreased following intervention (137.2 ± 14.6° to 129.7 ± 16.6°), but not significantly. Conversely, gait speed, step length, and cadence were unchanged after intervention. [Conclusion] A single-time RAGT with HAL improved single-leg support per gait cycle and hip and knee joint angle during gait, therapeutically improving gait function in CP patients. PMID:29545679

  20. Capability of 2 gait measures for detecting response to gait training in stroke survivors: Gait Assessment and Intervention Tool and the Tinetti Gait Scale.

    PubMed

    Zimbelman, Janice; Daly, Janis J; Roenigk, Kristen L; Butler, Kristi; Burdsall, Richard; Holcomb, John P

    2012-01-01

    To characterize the performance of 2 observational gait measures, the Tinetti Gait Scale (TGS) and the Gait Assessment and Intervention Tool (G.A.I.T.), in identifying improvement in gait in response to gait training. In secondary analysis from a larger study of multimodal gait training for stroke survivors, we measured gait at pre-, mid-, and posttreatment according to G.A.I.T. and TGS, assessing their capability to capture recovery of coordinated gait components. Large medical center. Cohort of stroke survivors (N=44) greater than 6 months after stroke. All subjects received 48 sessions of a multimodal gait-training protocol. Treatment consisted of 1.5 hours per session, 4 sessions per week for 12 weeks, receiving these 3 treatment aspects: (1) coordination exercise, (2) body weight-supported treadmill training, and (3) overground gait training, with 46% of subjects receiving functional electrical stimulation. All subjects were evaluated with the G.A.I.T. and TGS before and after completing the 48-session intervention. An additional evaluation was performed at midtreatment (after session 24). For the total subject sample, there were significant pre-/post-, pre-/mid-, and mid-/posttreatment gains for both the G.A.I.T. and the TGS. According to the G.A.I.T., 40 subjects (91%) showed improved scores, 2 (4%) no change, and 2 (4%) a worsening score. According to the TGS, only 26 subjects (59%) showed improved scores, 16 (36%) no change, and 1 (2%) a worsening score. For 1 treatment group of chronic stroke survivors, the TGS failed to identify a significant treatment response to gait training, whereas the G.A.I.T. measure was successful. The G.A.I.T. is more sensitive than the TGS for individual patients and group treatment response in identifying recovery of volitional control of gait components in response to gait training. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  1. A 12-Week Cycling Training Regimen Improves Gait and Executive Functions Concomitantly in People with Parkinson’s Disease

    PubMed Central

    Nadeau, Alexandra; Lungu, Ovidiu; Duchesne, Catherine; Robillard, Marie-Ève; Bore, Arnaud; Bobeuf, Florian; Plamondon, Réjean; Lafontaine, Anne-Louise; Gheysen, Freja; Bherer, Louis; Doyon, Julien

    2017-01-01

    Background: There is increasing evidence that executive functions and attention are associated with gait and balance, and that this link is especially prominent in older individuals or those who are afflicted by neurodegenerative diseases that affect cognition and/or motor functions. People with Parkinson’s disease (PD) often present gait disturbances, which can be reduced when PD patients engage in different types of physical exercise (PE), such as walking on a treadmill. Similarly, PE has also been found to improve executive functions in this population. Yet, no exercise intervention investigated simultaneously gait and non-motor symptoms (executive functions, motor learning) in PD patients. Objective: To assess the impact of aerobic exercise training (AET) using a stationary bicycle on a set of gait parameters (walking speed, cadence, step length, step width, single and double support time, as well as variability of step length, step width and double support time) and executive functions (cognitive inhibition and flexibility) in sedentary PD patients and healthy controls. Methods: Two groups, 19 PD patients (Hoehn and Yahr ≤2) and 20 healthy adults, matched on age and sedentary level, followed a 3-month stationary bicycle AET regimen. Results: Aerobic capacity, as well as performance of motor learning and on cognitive inhibition, increased significantly in both groups after the training regimen, but only PD patients improved their walking speed and cadence (all p < 0.05; with no change in the step length). Moreover, in PD patients, training-related improvements in aerobic capacity correlated positively with improvements in walking speed (r = 0.461, p < 0.05). Conclusion: AET using stationary bicycle can independently improve gait and cognitive inhibition in sedentary PD patients. Given that increases in walking speed were obtained through increases in cadence, with no change in step length, our findings suggest that gait improvements are specific to the type

  2. Analysis of foot load during ballet dancers' gait.

    PubMed

    Prochazkova, Marketa; Tepla, Lucie; Svoboda, Zdenek; Janura, Miroslav; Cieslarová, Miloslava

    2014-01-01

    Ballet is an art that puts extreme demands on the dancer's musculoskeletal system and therefore significantly affects motor behavior of the dancers. The aim of our research was to compare plantar pressure distribution during stance phase of gait between a group of professional ballet dancers and non-dancers. Thirteen professional dancers (5 men, 8 women; mean age of 24.1 ± 3.8 years) and 13 nondancers (5 men, 8 women; mean age of 26.1 ± 5.3 years) participated in this study. Foot pressure analysis during gait was collected using a 2 m pressure plate. The participants were instructed to walk across the platform at a self-selected pace barefoot. Three gait cycles were necessary for the data analysis. The results revealed higher (p < 0.05) pressure peaks in medial edge of forefoot during gait for dancers in comparison with nondancers. Furthermore, differences in total foot loading and foot loading duration of rearfoot was higher (p < 0.05) in dancers as well. We can attribute these differences to long-term and intensive dancing exercises that can change the dancer's gait stereotype.

  3. The influence of age on gait parameters during the transition from a wide to a narrow pathway.

    PubMed

    Shkuratova, Nataliya; Taylor, Nicholas

    2008-06-01

    The ability to negotiate pathways of different widths is a prerequisite of daily living. However, only a few studies have investigated changes in gait parameters in response to walking on narrow pathways. The aim of this study is to examine the influence of age on gait adjustments during the transition from a wide to a narrow pathway. Two-group repeated measures design. Gait Laboratory. Twenty healthy older participants (mean [M] = 74.3 years, Standard deviation [SD] = 7.2 years); 20 healthy young participants (M = 26.6 years, SD = 6.1 years). Making the transition from walking on a wide pathway (68 cm) to walking on a narrow pathway (15 cm). Step length, step time, step width, double support time and base of support. Healthy older participants were able to make the transition from a wide to a narrow pathway successfully. There was only one significant interaction, between age and base of support (p < 0.003). Older adults decreased their base of support only when negotiating the transition step, while young participants started decreasing their base of support prior to the negotiation of transition step (p < 0.01). Adjustments to the transition from a wide to a narrow pathway are largely unaffected by normal ageing. Difficulties in making the transition to a narrow pathway during walking should not be attributed to normal age-related changes. (c) 2008 John Wiley & Sons, Ltd.

  4. Pilot study of the impact that bilateral sacroiliac joint manipulation using a drop table technique has on gait parameters in asymptomatic individuals with a leg length inequality.

    PubMed

    Ward, John; Sorrels, Ken; Coats, Jesse; Pourmoghaddam, Amir; Deleon, Carlos; Daigneault, Paige

    2014-03-01

    The purpose of this study was to pilot test our study procedures and estimate parameters for sample size calculations for a randomized controlled trial to determine if bilateral sacroiliac (SI) joint manipulation affects specific gait parameters in asymptomatic individuals with a leg length inequality (LLI). Twenty-one asymptomatic chiropractic students engaged in a baseline 90-second walking kinematic analysis using infrared Vicon® cameras. Following this, participants underwent a functional LLI test. Upon examination participants were classified as: left short leg, right short leg, or no short leg. Half of the participants in each short leg group were then randomized to receive bilateral corrective SI joint chiropractic manipulative therapy (CMT). All participants then underwent another 90-second gait analysis. Pre- versus post-intervention gait data were then analyzed within treatment groups by an individual who was blinded to participant group status. For the primary analysis, all p-values were corrected for multiple comparisons using the Bonferroni method. Within groups, no differences in measured gait parameters were statistically significant after correcting for multiple comparisons. The protocol of this study was acceptable to all subjects who were invited to participate. No participants refused randomization. Based on the data collected, we estimated that a larger main study would require 34 participants in each comparison group to detect a moderate effect size.

  5. Automatic Setting Procedure for Exoskeleton-Assisted Overground Gait: Proof of Concept on Stroke Population.

    PubMed

    Gandolla, Marta; Guanziroli, Eleonora; D'Angelo, Andrea; Cannaviello, Giovanni; Molteni, Franco; Pedrocchi, Alessandra

    2018-01-01

    Stroke-related locomotor impairments are often associated with abnormal timing and intensity of recruitment of the affected and non-affected lower limb muscles. Restoring the proper lower limbs muscles activation is a key factor to facilitate recovery of gait capacity and performance, and to reduce maladaptive plasticity. Ekso is a wearable powered exoskeleton robot able to support over-ground gait training. The user controls the exoskeleton by triggering each single step during the gait cycle. The fine-tuning of the exoskeleton control system is crucial-it is set according to the residual functional abilities of the patient, and it needs to ensure lower limbs powered gait to be the most physiological as possible. This work focuses on the definition of an automatic calibration procedure able to detect the best Ekso setting for each patient. EMG activity has been recorded from Tibialis Anterior, Soleus, Rectus Femoris, and Semitendinosus muscles in a group of 7 healthy controls and 13 neurological patients. EMG signals have been processed so to obtain muscles activation patterns. The mean muscular activation pattern derived from the controls cohort has been set as reference. The developed automatic calibration procedure requires the patient to perform overground walking trials supported by the exoskeleton while changing parameters setting. The Gait Metric index is calculated for each trial, where the closer the performance is to the normative muscular activation pattern, in terms of both relative amplitude and timing, the higher the Gait Metric index is. The trial with the best Gait Metric index corresponds to the best parameters set. It has to be noted that the automatic computational calibration procedure is based on the same number of overground walking trials, and the same experimental set-up as in the current manual calibration procedure. The proposed approach allows supporting the rehabilitation team in the setting procedure. It has been demonstrated to be

  6. Automatic Setting Procedure for Exoskeleton-Assisted Overground Gait: Proof of Concept on Stroke Population

    PubMed Central

    Gandolla, Marta; Guanziroli, Eleonora; D'Angelo, Andrea; Cannaviello, Giovanni; Molteni, Franco; Pedrocchi, Alessandra

    2018-01-01

    Stroke-related locomotor impairments are often associated with abnormal timing and intensity of recruitment of the affected and non-affected lower limb muscles. Restoring the proper lower limbs muscles activation is a key factor to facilitate recovery of gait capacity and performance, and to reduce maladaptive plasticity. Ekso is a wearable powered exoskeleton robot able to support over-ground gait training. The user controls the exoskeleton by triggering each single step during the gait cycle. The fine-tuning of the exoskeleton control system is crucial—it is set according to the residual functional abilities of the patient, and it needs to ensure lower limbs powered gait to be the most physiological as possible. This work focuses on the definition of an automatic calibration procedure able to detect the best Ekso setting for each patient. EMG activity has been recorded from Tibialis Anterior, Soleus, Rectus Femoris, and Semitendinosus muscles in a group of 7 healthy controls and 13 neurological patients. EMG signals have been processed so to obtain muscles activation patterns. The mean muscular activation pattern derived from the controls cohort has been set as reference. The developed automatic calibration procedure requires the patient to perform overground walking trials supported by the exoskeleton while changing parameters setting. The Gait Metric index is calculated for each trial, where the closer the performance is to the normative muscular activation pattern, in terms of both relative amplitude and timing, the higher the Gait Metric index is. The trial with the best Gait Metric index corresponds to the best parameters set. It has to be noted that the automatic computational calibration procedure is based on the same number of overground walking trials, and the same experimental set-up as in the current manual calibration procedure. The proposed approach allows supporting the rehabilitation team in the setting procedure. It has been demonstrated to be

  7. Effects of the bilateral isokinetic strengthening training on functional parameters, gait, and the quality of life in patients with stroke.

    PubMed

    Büyükvural Şen, Sıdıka; Özbudak Demir, Sibel; Ekiz, Timur; Özgirgin, Neşe

    2015-01-01

    To evaluate the effects of the bilateral isokinetic strengthening training applied to knee and ankle muscles on balance, functional parameters, gait, and the quality of in stroke patients. Fifty patients (33 M, 17 F) with subacute-chronic stroke and 30 healthy subjects were included. Stroke patients were allocated into isokinetic and control groups. Conventional rehabilitation program was applied to all cases; additionally maximal concentric isokinetic strengthening training was applied to the knee-ankle muscles bilaterally to the isokinetic group 5 days a week for 3 weeks. Biodex System 3 Pro Multijoint System isokinetic dynamometer was used for isokinetic evaluation. The groups were assessed by Functional Independence Measure, Stroke Specific Quality of Life Scale, Timed 10-Meter Walk Test, Six-Minute Walk Test, Stair-Climbing Test, Timed up&go Test, Berg Balance Scale, and Rivermead Mobility Index. Compared with baseline, the isokinetic PT values of the knee and ankle on both sides significantly increased in all cases. PT change values were significantly higher in the isokinetic group than the control group (P<0.025). Furthermore, the quality of life, gait, balance and mobility index values improved significantly in both groups, besides the increase levels were found significantly higher in the isokinetic group (P<0.025, P<0.05). Bilateral isokinetic strengthening training in addition to conventional rehabilitation program after stroke seems to be effective on strengthening muscles on both sides, improving functional parameters, gait, balance and life quality.

  8. Effects of the bilateral isokinetic strengthening training on functional parameters, gait, and the quality of life in patients with stroke

    PubMed Central

    Büyükvural Şen, Sıdıka; Özbudak Demir, Sibel; Ekiz, Timur; Özgirgin, Neşe

    2015-01-01

    Objective: To evaluate the effects of the bilateral isokinetic strengthening training applied to knee and ankle muscles on balance, functional parameters, gait, and the quality of in stroke patients. Methods: Fifty patients (33 M, 17 F) with subacute-chronic stroke and 30 healthy subjects were included. Stroke patients were allocated into isokinetic and control groups. Conventional rehabilitation program was applied to all cases; additionally maximal concentric isokinetic strengthening training was applied to the knee-ankle muscles bilaterally to the isokinetic group 5 days a week for 3 weeks. Biodex System 3 Pro Multijoint System isokinetic dynamometer was used for isokinetic evaluation. The groups were assessed by Functional Independence Measure, Stroke Specific Quality of Life Scale, Timed 10-Meter Walk Test, Six-Minute Walk Test, Stair-Climbing Test, Timed up&go Test, Berg Balance Scale, and Rivermead Mobility Index. Results: Compared with baseline, the isokinetic PT values of the knee and ankle on both sides significantly increased in all cases. PT change values were significantly higher in the isokinetic group than the control group (P<0.025). Furthermore, the quality of life, gait, balance and mobility index values improved significantly in both groups, besides the increase levels were found significantly higher in the isokinetic group (P<0.025, P<0.05). Conclusion: Bilateral isokinetic strengthening training in addition to conventional rehabilitation program after stroke seems to be effective on strengthening muscles on both sides, improving functional parameters, gait, balance and life quality. PMID:26629238

  9. Comparison between treadmill training with rhythmic auditory stimulation and ground walking with rhythmic auditory stimulation on gait ability in chronic stroke patients: A pilot study.

    PubMed

    Park, Jin; Park, So-yeon; Kim, Yong-wook; Woo, Youngkeun

    2015-01-01

    Generally, treadmill training is very effective intervention, and rhythmic auditory stimulation is designed to feedback during gait training in stroke patients. The purpose of this study was to compare the gait abilities in chronic stroke patients following either treadmill walking training with rhythmic auditory stimulation (TRAS) or over ground walking training with rhythmic auditory stimulation (ORAS). Nineteen subjects were divided into two groups: a TRAS group (9 subjects) and an ORAS group (10 subjects). Temporal and spatial gait parameters and motor recovery ability were measured before and after the training period. Gait ability was measured by the Biodex Gait trainer treadmill system, Timed up and go test (TUG), 6 meter walking distance (6MWD) and Functional gait assessment (FGA). After the training periods, the TRAS group showed a significant improvement in walking speed, step cycle, step length of the unaffected limb, coefficient of variation, 6MWD, and, FGA when compared to the ORAS group (p <  0.05). Treadmill walking training during the rhythmic auditory stimulation may be useful for rehabilitation of patients with chronic stroke.

  10. Automated health alerts from Kinect-based in-home gait measurements.

    PubMed

    Stone, Erik E; Skubic, Marjorie; Back, Jessica

    2014-01-01

    A method for automatically generating alerts to clinicians in response to changes in in-home gait parameters is investigated. Kinect-based gait measurement systems were installed in apartments in a senior living facility. The systems continuously monitored the walking speed, stride time, and stride length of apartment residents. A framework for modeling uncertainty in the residents' gait parameter estimates, which is critical for robust change detection, is developed; along with an algorithm for detecting changes that may be clinically relevant. Three retrospective case studies, of individuals who had their gait monitored for periods ranging from 12 to 29 months, are presented to illustrate use of the alert method. Evidence suggests that clinicians could be alerted to health changes at an early stage, while they are still small and interventions may be most successful. Additional potential uses are also discussed.

  11. Overground robot assisted gait trainer for the treatment of drug-resistant freezing of gait in Parkinson disease.

    PubMed

    Pilleri, Manuela; Weis, Luca; Zabeo, Letizia; Koutsikos, Konstantinos; Biundo, Roberta; Facchini, Silvia; Rossi, Simonetta; Masiero, Stefano; Antonini, Angelo

    2015-08-15

    Freezing of Gait (FOG) is a frequent and disabling feature of Parkinson disease (PD). Gait rehabilitation assisted by electromechanical devices, such as training on treadmill associated with sensory cues or assisted by gait orthosis have been shown to improve FOG. Overground robot assisted gait training (RGT) has been recently tested in patients with PD with improvement of several gait parameters. We here evaluated the effectiveness of RGT on FOG severity and gait abnormalities in PD patients. Eighteen patients with FOG resistant to dopaminergic medications were treated with 15 sessions of RGT and underwent an extensive clinical evaluation before and after treatment. The main outcome measures were FOG questionnaire (FOGQ) global score and specific tasks for gait assessment, namely 10 meter walking test (10 MWT), Timed Up and Go test (TUG) and 360° narrow turns (360 NT). Balance was also evaluated through Fear of Falling Efficacy Scale (FFES), assessing self perceived stability and Berg Balance Scale (BBS), for objective examination. After treatment, FOGQ score was significantly reduced (P=0.023). We also found a significant reduction of time needed to complete TUG, 10 MWT, and 360 NT (P=0.009, 0.004 and 0.04, respectively). By contrast the number of steps and the number of freezing episodes recorded at each gait task did not change. FFES and BBS scores also improved, with positive repercussions on performance on daily activity and quality of life. Our results indicate that RGT is a useful strategy for the treatment of drug refractory FOG. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Asymmetry in gait pattern following tibial shaft fractures - a prospective one-year follow-up study of 49 patients.

    PubMed

    Larsen, Peter; Laessoe, Uffe; Rasmussen, Sten; Graven-Nielsen, Thomas; Berre Eriksen, Christian; Elsoe, Rasmus

    2017-01-01

    Despite the high number of studies evaluating the outcomes following tibial shaft fractures, the literature lacks studies including objective assessment of patients' recovery regarding gait pattern. The purpose of the present study was to evaluate whether gait patterns at 6 and 12 months post-operatively following intramedullary nailing of a tibial shaft fracture are different compared with a healthy reference population. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns at 6 and 12 months post-operatively measured with a 6-metre-long pressure-sensitive mat. The mat registers footprints and present gait speed, cadence as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. 49 patients were included with a mean age of 43.1 years (18-79 years). Forty-three patients completed the 12-month follow-up (88%). Gait speed and cadence were significantly increased between the 6- and 12-month follow-up (P<0.001). At 6-month follow-up, patients showed considerable asymmetry in the injured leg compared with the non-injured leg: single-support time 12.8% shorter, swing-time 12.8% longer, step-length 11.9% shorter, and rotation of the foot increased by 32.3%. At the 12-month follow-up, gait asymmetry become almost normalized compared to a healthy reference group. In patients treated by intramedullary nailing following a tibial shaft fracture, gait asymmetry accompanied with slower speed and cadence are common during the first 6 months and become normalized compared with a healthy reference population between 6 and 12 months post-operatively. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Positive outcomes following gait therapy intervention for hip osteoarthritis: A longitudinal study.

    PubMed

    Solomonow-Avnon, Deborah; Herman, Amir; Levin, Daniel; Rozen, Nimrod; Peled, Eli; Wolf, Alon

    2017-10-01

    Footwear-generated biomechanical manipulation of lower-limb joints was shown to beneficially impact gait and quality of life in knee osteoarthritis patients, but has not been tested in hip osteoarthritis patients. We examined a customized gait treatment program using a biomechanical device shown in previous investigations to be capable of manipulating hip biomechanics via foot center of pressure (COP) modulation. The objective of this study was to assess the treatment program for hip osteoarthritis patients, enrolled in a 1-year prospective investigation, by means of objective gait and spatiotemporal parameters, and subjective quality of life measures. Gait analysis and completion of questionnaires were performed at the start of the treatment (baseline), and after 3, 6, and 12 months. Outcome parameters were evaluated over time using linear mixed effects models, and association between improvement in quality of life measures and change in objective outcomes was tested using mixed effect linear regression models. Quality of life measures improved compared to baseline, accompanied by increased gait speed and cadence. Sagittal-plane hip joint kinetics, kinematics, and spatiotemporal parameters changed throughout the study compared to baseline, in a manner suggesting improvement of gait. The most substantial improvement occurred within 3 months after treatment initiation, after which improvement approximately plateaued, but was sustained at 12 months. Speed and cadence, as well as several sagittal-plane gait parameters, were significant predictors of improvement in quality of life. Evidence suggests that a biomechanical gait therapy program improves subjective and objective outcomes measures and is a valid treatment option for hip osteoarthritis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2222-2232, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. Is the Limit-Cycle-Attractor an (almost) invariable characteristic in human walking?

    PubMed

    Broscheid, Kim-Charline; Dettmers, Christian; Vieten, Manfred

    2018-05-16

    Common methods of gait analyses measure step length/width, gait velocity and gait variability to name just a few. Those parameters tend to be changing with fitness and skill of the subjects. But, do stable subject characteristic parameters in walking exist? Does the Limit-Cycle-Attractor qualify as such a parameter?. The attractor method is a new approach focusing on the dynamics of human motion. It classifies the fundamental walking pattern by calculating the Limit-Cycle-Attractor and its variability from acceleration data of the feet. Our hypothesis is that the fundamental walking pattern in healthy controls and in people with Multiple Sclerosis (pwMS) is stable, but can be altered through acute interventions or rehabilitation. For this purpose, two investigations were conducted involving 113 subjects. The short-term stability was tested pre and post a 15 min passive/active MOTOmed (ergometer) session as well as up to 20 min afterwards. The long-term stability was tested over five weeks of rehabilitation once a week in pwMS. The main parameter of interest describes the velocity normalized average difference between two attractors (δM), which is an indicator for the change in movement pattern. The Friedman's two-way ANOVA by ranks did not reveal any significant difference in δM. However, the conventional walking tests (6 min.10 m) improved significantly (p < 0.05) during rehabilitation. Contrary to our original hypothesis, the fundamental walking pattern was highly stable against controlled motor-assisted movement initiation via MOTOmed and rehabilitation treatment. Movement characteristics appeared to be independent of the improved fitness as indicated by the enhanced walking speed and distance. The individual Limit-Cycle-Attractor is extremely robust and might indeed qualify as an (almost) invariable characteristic in human walking. This opens up the possibility to encode the individual walking characteristics. Conditions as Parkinson, Multiple

  15. The effect of functional electrical stimulation cycling on late functional improvement in patients with chronic incomplete spinal cord injury.

    PubMed

    Yaşar, E; Yılmaz, B; Göktepe, S; Kesikburun, S

    2015-12-01

    Prospective single-arm study. To investigate the effect of functional electrical stimulation (FES) cycling on late functional recovery, spasticity, gait parameters and oxygen consumption during walking in patients with chronic incomplete spinal cord injury (SCI). Turkish Armed Forces Rehabilitation Center, Ankara, Turkey. Ten patients with chronic (duration of more than 2 years) incomplete SCI who could ambulate at least 10 m independently or with the assistance of a cane or walker, but no hip-knee-ankle-foot orthosis. The subjects underwent 1-h FES cycling sessions three times a week for 16 weeks. Outcome measures including the total motor score, the Functional Independence Measure (FIM) score, the Modified Ashworth Scale for knee spasticity, temporal spatial gait parameters and oxygen consumption rate during walking were assessed at baseline, 3 and 6 months after the baseline. There were statistically significant improvements in total motor scores, the FIM scores and spasticity level at the 6-month follow-up (P<0.01). The changes in gait parameters reached no significant level (P>0.05). Oxygen consumption rate of the patients showed significant reduction at only 6 months compared with baseline (P<0.01). The results suggest that FES cycling may provide some functional improvements in the late period of SCI. The study was supported by The Scientific and Technological Research Council of Turkey (TUBITAK).

  16. Gait Phase Recognition for Lower-Limb Exoskeleton with Only Joint Angular Sensors

    PubMed Central

    Liu, Du-Xin; Wu, Xinyu; Du, Wenbin; Wang, Can; Xu, Tiantian

    2016-01-01

    Gait phase is widely used for gait trajectory generation, gait control and gait evaluation on lower-limb exoskeletons. So far, a variety of methods have been developed to identify the gait phase for lower-limb exoskeletons. Angular sensors on lower-limb exoskeletons are essential for joint closed-loop controlling; however, other types of sensors, such as plantar pressure, attitude or inertial measurement unit, are not indispensable.Therefore, to make full use of existing sensors, we propose a novel gait phase recognition method for lower-limb exoskeletons using only joint angular sensors. The method consists of two procedures. Firstly, the gait deviation distances during walking are calculated and classified by Fisher’s linear discriminant method, and one gait cycle is divided into eight gait phases. The validity of the classification results is also verified based on large gait samples. Secondly, we build a gait phase recognition model based on multilayer perceptron and train it with the phase-labeled gait data. The experimental result of cross-validation shows that the model has a 94.45% average correct rate of set (CRS) and an 87.22% average correct rate of phase (CRP) on the testing set, and it can predict the gait phase accurately. The novel method avoids installing additional sensors on the exoskeleton or human body and simplifies the sensory system of the lower-limb exoskeleton. PMID:27690023

  17. Quadrupedal rodent gait compensations in a low dose monoiodoacetate model of osteoarthritis.

    PubMed

    Lakes, Emily H; Allen, Kyle D

    2018-06-01

    Rodent gait analysis provides robust, quantitative results for preclinical musculoskeletal and neurological models. In prior work, surgical models of osteoarthritis have been found to result in a hind limb shuffle-stepping gait compensation, while a high dose monoiodoacetate (MIA, 3 mg) model resulted in a hind limb antalgic gait. However, it is unknown whether the antalgic gait caused by MIA is associated with severity of degeneration from the high dosage or the whole-joint degeneration associated with glycolysis inhibition. This study evaluates rodent gait changes resulting from a low dose, 1 mg unilateral intra-articular injection of MIA compared to saline injected and naïve rats. Spatiotemporal and dynamic gait parameters were collected from a total of 42 male Lewis rats spread across 3 time points: 1, 2, and 4 weeks post-injection. To provide a detailed analysis of this low dose MIA model, gait analysis was used to uniquely quantify both fore and hind limb gait parameters. Our data indicate that 1 mg of MIA caused relatively minor degeneration and a shuffle-step gait compensation, similar to the compensation observed in prior surgical models. These data from a 1 mg MIA model show a different gait compensation compared to a previously studied 3 mg model. This 1 mg MIA model resulted in gait compensations more similar to a previously studied surgical model of osteoarthritis. Additionally, this study provides detailed 4 limb analysis of rodent gait that includes spatiotemporal and dynamic data from the same gait trial. These data highlight the importance of measuring dynamic data in combination with spatiotemporal data, since compensatory gait patterns may not be captured by spatial, temporal, or dynamic characterizations alone. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Improved gait after repetitive locomotor training in children with cerebral palsy.

    PubMed

    Smania, Nicola; Bonetti, Paola; Gandolfi, Marialuisa; Cosentino, Alessandro; Waldner, Andreas; Hesse, Stefan; Werner, Cordula; Bisoffi, Giulia; Geroin, Christian; Munari, Daniele

    2011-02-01

    The aim of this study was to evaluate the effectiveness of repetitive locomotor training with an electromechanical gait trainer in children with cerebral palsy. In this randomized controlled trial, 18 ambulatory children with diplegic or tetraplegic cerebral palsy were randomly assigned to an experimental group or a control group. The experimental group received 30 mins of repetitive locomotor training with an applied technology (Gait Trainer GT I) plus 10 mins of passive joint mobilization and stretching exercises. The control group received 40 mins of conventional physiotherapy. Each subject underwent a total of 10 treatment sessions over a 2-wk period. Performance on the 10-m walk test, 6-min walk test, WeeFIM scale, and gait analysis was evaluated by a blinded rater before and after treatment and at 1-mo follow-up. The experimental group showed significant posttreatment improvement on the 10-m walk test, 6-min walk test, hip kinematics, gait speed, and step length, all of which were maintained at the 1-mo follow-up assessment. No significant changes in performance parameters were observed in the control group. Repetitive locomotor training with an electromechanical gait trainer may improve gait velocity, endurance, spatiotemporal, and kinematic gait parameters in patients with cerebral palsy.

  19. Mobile gait analysis via eSHOEs instrumented shoe insoles: a pilot study for validation against the gold standard GAITRite®.

    PubMed

    Jagos, Harald; Pils, Katharina; Haller, Michael; Wassermann, Claudia; Chhatwal, Christa; Rafolt, Dietmar; Rattay, Frank

    2017-07-01

    Clinical gait analysis contributes massively to rehabilitation support and improvement of in-patient care. The research project eSHOE aspires to be a useful addition to the rich variety of gait analysis systems. It was designed to fill the gap of affordable, reasonably accurate and highly mobile measurement devices. With the overall goal of enabling individual home-based monitoring and training for people suffering from chronic diseases, affecting the locomotor system. Motion and pressure sensors gather movement data directly on the (users) feet, store them locally and/or transmit them wirelessly to a PC. A combination of pattern recognition and feature extraction algorithms translates the motion data into standard gait parameters. Accuracy of eSHOE were evaluated against the reference system GAITRite in a clinical pilot study. Eleven hip fracture patients (78.4 ± 7.7 years) and twelve healthy subjects (40.8 ± 9.1 years) were included in these trials. All subjects performed three measurements at a comfortable walking speed over 8 m, including the 6-m long GAITRite mat. Six standard gait parameters were extracted from a total of 347 gait cycles. Agreement was analysed via scatterplots, histograms and Bland-Altman plots. In the patient group, the average differences between eSHOE and GAITRite range from -0.046 to 0.045 s and in the healthy group from -0.029 to 0.029 s. Therefore, it can be concluded that eSHOE delivers adequately accurate results. Especially with the prospect as an at home supplement or follow-up to clinical gait analysis and compared to other state of the art wearable motion analysis systems.

  20. Monitoring gait in multiple sclerosis with novel wearable motion sensors.

    PubMed

    Moon, Yaejin; McGinnis, Ryan S; Seagers, Kirsten; Motl, Robert W; Sheth, Nirav; Wright, John A; Ghaffari, Roozbeh; Sosnoff, Jacob J

    2017-01-01

    Mobility impairment is common in people with multiple sclerosis (PwMS) and there is a need to assess mobility in remote settings. Here, we apply a novel wireless, skin-mounted, and conformal inertial sensor (BioStampRC, MC10 Inc.) to examine gait characteristics of PwMS under controlled conditions. We determine the accuracy and precision of BioStampRC in measuring gait kinematics by comparing to contemporary research-grade measurement devices. A total of 45 PwMS, who presented with diverse walking impairment (Mild MS = 15, Moderate MS = 15, Severe MS = 15), and 15 healthy control subjects participated in the study. Participants completed a series of clinical walking tests. During the tests participants were instrumented with BioStampRC and MTx (Xsens, Inc.) sensors on their shanks, as well as an activity monitor GT3X (Actigraph, Inc.) on their non-dominant hip. Shank angular velocity was simultaneously measured with the inertial sensors. Step number and temporal gait parameters were calculated from the data recorded by each sensor. Visual inspection and the MTx served as the reference standards for computing the step number and temporal parameters, respectively. Accuracy (error) and precision (variance of error) was assessed based on absolute and relative metrics. Temporal parameters were compared across groups using ANOVA. Mean accuracy±precision for the BioStampRC was 2±2 steps error for step number, 6±9ms error for stride time and 6±7ms error for step time (0.6-2.6% relative error). Swing time had the least accuracy±precision (25±19ms error, 5±4% relative error) among the parameters. GT3X had the least accuracy±precision (8±14% relative error) in step number estimate among the devices. Both MTx and BioStampRC detected significantly distinct gait characteristics between PwMS with different disability levels (p<0.01). BioStampRC sensors accurately and precisely measure gait parameters in PwMS across diverse walking impairment levels and detected

  1. Monitoring gait in multiple sclerosis with novel wearable motion sensors

    PubMed Central

    McGinnis, Ryan S.; Seagers, Kirsten; Motl, Robert W.; Sheth, Nirav; Wright, John A.; Ghaffari, Roozbeh; Sosnoff, Jacob J.

    2017-01-01

    Background Mobility impairment is common in people with multiple sclerosis (PwMS) and there is a need to assess mobility in remote settings. Here, we apply a novel wireless, skin-mounted, and conformal inertial sensor (BioStampRC, MC10 Inc.) to examine gait characteristics of PwMS under controlled conditions. We determine the accuracy and precision of BioStampRC in measuring gait kinematics by comparing to contemporary research-grade measurement devices. Methods A total of 45 PwMS, who presented with diverse walking impairment (Mild MS = 15, Moderate MS = 15, Severe MS = 15), and 15 healthy control subjects participated in the study. Participants completed a series of clinical walking tests. During the tests participants were instrumented with BioStampRC and MTx (Xsens, Inc.) sensors on their shanks, as well as an activity monitor GT3X (Actigraph, Inc.) on their non-dominant hip. Shank angular velocity was simultaneously measured with the inertial sensors. Step number and temporal gait parameters were calculated from the data recorded by each sensor. Visual inspection and the MTx served as the reference standards for computing the step number and temporal parameters, respectively. Accuracy (error) and precision (variance of error) was assessed based on absolute and relative metrics. Temporal parameters were compared across groups using ANOVA. Results Mean accuracy±precision for the BioStampRC was 2±2 steps error for step number, 6±9ms error for stride time and 6±7ms error for step time (0.6–2.6% relative error). Swing time had the least accuracy±precision (25±19ms error, 5±4% relative error) among the parameters. GT3X had the least accuracy±precision (8±14% relative error) in step number estimate among the devices. Both MTx and BioStampRC detected significantly distinct gait characteristics between PwMS with different disability levels (p<0.01). Conclusion BioStampRC sensors accurately and precisely measure gait parameters in PwMS across diverse walking

  2. Statistical Parametric Mapping to Identify Differences between Consensus-Based Joint Patterns during Gait in Children with Cerebral Palsy

    PubMed Central

    Papageorgiou, Eirini; Desloovere, Kaat; Molenaers, Guy; De Laet, Tinne

    2017-01-01

    Experts recently identified 49 joint motion patterns in children with cerebral palsy during a Delphi consensus study. Pattern definitions were therefore the result of subjective expert opinion. The present study aims to provide objective, quantitative data supporting the identification of these consensus-based patterns. To do so, statistical parametric mapping was used to compare the mean kinematic waveforms of 154 trials of typically developing children (n = 56) to the mean kinematic waveforms of 1719 trials of children with cerebral palsy (n = 356), which were classified following the classification rules of the Delphi study. Three hypotheses stated that: (a) joint motion patterns with ‘no or minor gait deviations’ (n = 11 patterns) do not differ significantly from the gait pattern of typically developing children; (b) all other pathological joint motion patterns (n = 38 patterns) differ from typically developing gait and the locations of difference within the gait cycle, highlighted by statistical parametric mapping, concur with the consensus-based classification rules. (c) all joint motion patterns at the level of each joint (n = 49 patterns) differ from each other during at least one phase of the gait cycle. Results showed that: (a) ten patterns with ‘no or minor gait deviations’ differed somewhat unexpectedly from typically developing gait, but these differences were generally small (≤3°); (b) all other joint motion patterns (n = 38) differed from typically developing gait and the significant locations within the gait cycle that were indicated by the statistical analyses, coincided well with the classification rules; (c) joint motion patterns at the level of each joint significantly differed from each other, apart from two sagittal plane pelvic patterns. In addition to these results, for several joints, statistical analyses indicated other significant areas during the gait cycle that were not included in the pattern definitions of the consensus

  3. Validity of the Kinect for Gait Assessment: A Focused Review

    PubMed Central

    Springer, Shmuel; Yogev Seligmann, Galit

    2016-01-01

    Gait analysis may enhance clinical practice. However, its use is limited due to the need for expensive equipment which is not always available in clinical settings. Recent evidence suggests that Microsoft Kinect may provide a low cost gait analysis method. The purpose of this report is to critically evaluate the literature describing the concurrent validity of using the Kinect as a gait analysis instrument. An online search of PubMed, CINAHL, and ProQuest databases was performed. Included were studies in which walking was assessed with the Kinect and another gold standard device, and consisted of at least one numerical finding of spatiotemporal or kinematic measures. Our search identified 366 papers, from which 12 relevant studies were retrieved. The results demonstrate that the Kinect is valid only for some spatiotemporal gait parameters. Although the kinematic parameters measured by the Kinect followed the trend of the joint trajectories, they showed poor validity and large errors. In conclusion, the Kinect may have the potential to be used as a tool for measuring spatiotemporal aspects of gait, yet standardized methods should be established, and future examinations with both healthy subjects and clinical participants are required in order to integrate the Kinect as a clinical gait analysis tool. PMID:26861323

  4. Transplantation of Embryonic Cerebellar Grafts Improves Gait Parameters in Ataxic Lurcher Mice.

    PubMed

    Babuska, Vaclav; Houdek, Zbynek; Tuma, Jan; Purkartova, Zdenka; Tumova, Jana; Kralickova, Milena; Vozeh, Frantisek; Cendelin, Jan

    2015-12-01

    Hereditary cerebellar ataxias are severe diseases for which therapy is currently not sufficiently effective. One of the possible therapeutic approaches could be neurotransplantation. Lurcher mutant mice are a natural model of olivocerebellar degeneration representing a tool to investigate its pathogenesis as well as experimental therapies for hereditary cerebellar ataxias. The effect of intracerebellar transplantation of embryonic cerebellar solid tissue or cell suspension on motor performance in adult Lurcher mutant and healthy wild-type mice was studied. Brain-derived neurotrophic factor level was measured in the graft and adult cerebellar tissue. Gait analysis and rotarod, horizontal wire, and wooden beam tests were carried out 2 or 6 months after the transplantation. Higher level of the brain-derived neurotrophic factor was found in the Lurcher cerebellum than in the embryonic and adult wild-type tissue. A mild improvement of gait parameters was found in graft-treated Lurcher mice. The effect was more marked in cell suspension grafts than in solid transplants and after the longer period than after the short one. Lurcher mice treated with cell suspension and examined 6 months later had a longer hind paw stride (4.11 vs. 3.73 mm, P < 0.05) and higher swing speed for both forepaws (52.46 vs. 32.79 cm/s, P < 0.01) and hind paws (63.46 vs. 43.67 cm/s, P < 0.001) than controls. On the other hand, classical motor tests were not capable of detecting clearly the change in the motor performance. No strong long-lasting negative effect of the transplantation was seen in wild-type mice, suggesting that the treatment has no harmful impact on the healthy cerebellum.

  5. Quantitative gait analysis in parkin disease: Possible role of dystonia.

    PubMed

    Castagna, Anna; Frittoli, Serena; Ferrarin, Maurizio; Del Sorbo, Francesca; Romito, Luigi M; Elia, Antonio E; Albanese, Alberto

    2016-11-01

    Parkin disease (PARK2, OMIM 602544) is an autosomal-recessive early-onset parkinsonism characterized by an early occurrence of lower limb dystonia. The aim of this study was to analyze spatiotemporal, kinematic, and kinetic gait parameters in patients with parkin disease in the OFF and ON conditions compared to healthy age-matched controls. Fifteen patients with parkin disease and 15 healthy age-matched controls were studied in a gait analysis laboratory with an integrated optoelectronic system. Spatiotemporal, kinematic, and kinetic gait parameters at a self-selected speed were recorded in the OFF and ON conditions. A jerk index was computed to quantify the possible reduction of smoothness of joint movements. Compared to controls, parkin patients had, either in the OFF or in the ON conditions, significant reduction of walking velocity, increased step width, and decreased percentage of double support. Kinematic analysis in both conditions showed: increased ankle dorsiflexion and knee flexion at the initial contact; maximal flexion and increased range of motion in mid stance; increased hip flexion and max extension in stance at pelvis; and increased mean tilt antiversion. Kinetics showed increased hip and knee power generation in stance in either condition. The jerk index was increased at all joints both in OFF and ON. There were no correlations between individual gait parameters and clinical ratings. Parkin patients have an abnormal gait pattern that does not vary between the OFF and the ON conditions. Variations recorded with instrumented analysis are more evident for kinematic than kinetic parameters at lower limbs. Severity of dystonia does not correlate with any individual kinematic parameter. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.

  6. Gait initiation and termination strategies in patients with Prader-Willi syndrome.

    PubMed

    Cimolin, Veronica; Cau, Nicola; Galli, Manuela; Santovito, Cristina; Grugni, Graziano; Capodaglio, Paolo

    2017-05-23

    Gait Initiation (GI) is a functional task representing one of the first voluntary destabilizing behaviours observed in the development of a locomotor pattern as the whole body centre of mass transitions from a large to a small base of support. Conversely, Gait Termination (GT) consists in the transition from walking to standing which, in everyday life, is a very common movement. Compared to normal walking, it requires higher control of postural stability. For a safe GT, the forward movement of the body has to be slowed down to achieve a stable upright position. Stability requirements have to be fulfilled for safe GT. In individuals with Prader-Willi syndrome (PWS), excessive body weight negatively affects the movement, such as walking and posture, but there are no experimental studies about GI and GT in these individuals. The aim of this study was to quantitatively characterise the strategy of patients with PWS during GI and GT using parameters obtained by the Center of Pressure (CoP) track. Twelve patients with PWS, 20 obese (OG) and 19 healthy individuals (HG) were tested using a force platform during the GI and GT tasks. CoP plots were divided into different phases, and duration, length and velocity of the CoP trace in these phases were calculated and compared for each task. As for GI, the results showed a significant reduction of the task duration and lower velocity and CoP length parameters in PWS, compared to OG and HG. In PWS, those parameters were reduced to a higher degree with respect to the OG. During GT, longer durations, similar to OG, were observed in PWS than HG. Velocity is reduced when compared to OG and HG, especially in medio-lateral direction and in the terminal part of GT. From these data, GI appears to be a demanding task in most of its sub-phases for PWS individuals, while GT seems to require caution only towards the end of the task. Breaking the cycle of gait into the phases of GI and GT and implementing specific exercises focusing on weight

  7. Gait analysis in children with haemophilia: first Italian experience at the Turin Haemophilia Centre.

    PubMed

    Forneris, E; Andreacchio, A; Pollio, B; Mannucci, C; Franchini, M; Mengoli, C; Pagliarino, M; Messina, M

    2016-05-01

    To investigate the functional status in haemophilia patients referred to an Italian paediatric haemophilia centre using gait analysis, verifying any differences between mild, moderate or severe haemophilia at a functional level. Forty-two patients (age 4-18) presenting to the Turin Paediatric Haemophilia Centre who could walk independently were included. Therapy included prophylaxis (n = 21), on-demand (n = 17) or immune tolerance induction + inhibitor (n = 4). Patients performed a test of gait analysis. Temporal, spatial and kinematic parameters were calculated for patient subgroups by disease severity and background treatment, and compared with normal values. Moderate (35.7%) or severe (64.3%) haemophilia patients showed obvious variations from normal across a variety of temporal and spatial gait analysis parameters, including step speed and length, double support, swing phase, load asymmetry, stance phase, swing phase and speed. Kinematic parameters were characterized by frequent foot external rotation with deficient plantar flexion during the stance phase, retropelvic tilt, impaired power generation distally and reduced ground reaction forces. Both Gait Deviation Index and Gait Profile Score values for severe haemophilia patients indicated abnormal gait parameters, which were worst in patients with a history of past or current use of inhibitors and those receiving on-demand therapy. Functional evaluation identified changes in gait pattern in patients with severe and moderate haemophilia, compared with normal values. Gait analysis may be a useful tool to facilitate early diagnosis of joint damage, prevent haemophilic arthropathy, design a personalized rehabilitative treatment and monitor functional status over time. © 2016 John Wiley & Sons Ltd.

  8. Early presentation of gait impairment in Wolfram Syndrome

    PubMed Central

    2012-01-01

    Background Classically characterized by early onset insulin-dependent diabetes mellitus, optic atrophy, deafness, diabetes insipidus, and neurological abnormalities, Wolfram syndrome (WFS) is also associated with atypical brainstem and cerebellar findings in the first decade of life. As such, we hypothesized that gait differences between individuals with WFS and typically developing (TD) individuals may be detectable across the course of the disease. Methods Gait was assessed for 13 individuals with WFS (min 6.4 yrs, max 25.8 yrs) and 29 age-matched, typically developing individuals (min 5.6 yrs, max 28.5 yrs) using a GAITRite ® walkway system. Velocity, cadence, step length, base of support and double support time were compared between groups. Results Across all tasks, individuals with WFS walked slower (p = 0.03), took shorter (p ≤ 0.001) and wider (p ≤ 0.001) steps and spent a greater proportion of the gait cycle in double support (p = 0.03) compared to TD individuals. Cadence did not differ between groups (p = 0.62). Across all tasks, age was significantly correlated with cadence and double support time in the TD group but only double support time was correlated with age in the WFS group and only during preferred pace forward (rs= 0.564, p = 0.045) and dual task forward walking (rs= 0.720, p = 0.006) tasks. Individuals with WFS also had a greater number of missteps during tandem walking (p ≤ 0.001). Within the WFS group, spatiotemporal measures of gait did not correlate with measures of visual acuity. Balance measures negatively correlated with normalized gait velocity during fast forward walking (rs = −0.59, p = 0.03) and percent of gait cycle in double support during backward walking (rs = −0.64, p = 0.03). Conclusions Quantifiable gait impairments can be detected in individuals with WFS earlier than previous clinical observations suggested. These impairments are not fully accounted for by the visual or balance deficits associated with WFS

  9. Gait Patterns in Hemiplegic Children with Cerebral Palsy: Comparison of Right and Left Hemiplegia

    ERIC Educational Resources Information Center

    Galli, Manuela; Cimolin, Veronica; Rigoldi, Chiara; Tenore, Nunzio; Albertini, Giorgio

    2010-01-01

    The aims of this study are to compare quantitatively the gait strategy of the right and left hemiplegic children with Cerebral Palsy (CP) using gait analysis. The gait strategy of 28 right hemiparetic CP (RHG) and 23 left hemiparetic CP (LHG) was compared using gait analysis (spatio-temporal and kinematic parameters) and considering the hemiplegic…

  10. Does acupuncture ameliorate motor impairment after stroke? An assessment using the CatWalk gait system.

    PubMed

    Cao, Yan; Sun, Ning; Yang, Jing-Wen; Zheng, Yang; Zhu, Wen; Zhang, Zhen-Hua; Wang, Xue-Rui; Shi, Guang-Xia; Liu, Cun-Zhi

    2017-07-01

    The effect of acupuncture on gait deficits after stroke is uncertain. This animal study was designed to determine whether acupuncture improves gait impairment following experimentally induced ischemic stroke. Ischemic stroke was induced by permanent middle cerebral artery occlusion (MCAO) in rats. After 7 days' of acupuncture treatment, assessment of gait changes using the CatWalk automated gait analysis system was performed. Comparison of the CatWalk gait parameters among the groups showed that gait function was impaired after ischemic stroke and acupuncture treatment was effective in improving a variety of gait parameters including intensity, stance and swing time, swing speed and stride length at postoperative day 8. This study demonstrates a beneficial effect of acupuncture on gait impairment in rats following ischemic stroke. Further studies aimed to investigate the effects of acupuncture at different stages during stroke using the CatWalk system are required. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Technological Advances in Interventions to Enhance Post-Stroke Gait

    PubMed Central

    Sheffler, Lynne R.; Chae, John

    2012-01-01

    Synopsis This article provides a comprehensive review of specific rehabilitation interventions used to enhance hemiparetic gait following stroke. Neurologic rehabilitation interventions may be either therapeutic resulting in enhanced motor recovery or compensatory whereby assistance or substitution for neurological deficits results in improved functional performance. Included in this review are lower extremity functional electrical stimulation (FES), body-weight supported treadmill training (BWSTT), and lower extremity robotic-assisted gait training. These post-stroke gait training therapies are predicated on activity-dependent neuroplasticity which is the concept that cortical reorganization following central nervous system injury may be induced by repetitive, skilled, and cognitively engaging active movement. All three interventions have been trialed extensively in both research and clinical settings to demonstrate a positive effect on various gait parameters and measures of walking performance. However, more evidence is necessary to determine if specific technology-enhanced gait training methods are superior to conventional gait training methods. This review provides an overview of evidence-based research which supports the efficacy of these three interventions to improve gait, as well as provide perspective on future developments to enhance post-stroke gait in neurologic rehabilitation. PMID:23598265

  12. Effect of body mass index on hemiparetic gait.

    PubMed

    Sheffler, Lynne R; Bailey, Stephanie Nogan; Gunzler, Douglas; Chae, John

    2014-10-01

    To evaluate the relationship between body mass index (BMI) and spatiotemporal, kinematic, and kinetic gait parameters in chronic hemiparetic stroke survivors. Secondary analysis of data collected in a randomized controlled trial comparing two 12-week ambulation training treatments. Academic medical center. Chronic hemiparetic stroke survivors (N = 108, >3 months poststroke) Linear regression analyses were performed of BMI, and selected pretreatment gait parameters were recorded using quantitative gait analysis. Spatiotemporal, kinematic, and kinetic gait parameters. A series of linear regression models that controlled for age, gender, stroke type (ischemic versus hemorrhagic), interval poststroke, level of motor impairment (Fugl-Meyer score), and walking speed found BMI to be positively associated with step width (m) (β = 0.364, P < .001), positively associated with peak hip abduction angle of the nonparetic limb during stance (deg) (β = 0.177, P = .040), negatively associated with ankle dorsiflexion angle at initial contact of the paretic limb (deg) (β = -0.222, P = .023), and negatively associated with peak ankle power at push-off (W/kg) of the paretic limb (W/kg)(β = -0.142, P = .026). When walking at a similar speed, chronic hemiparetic stroke subjects with a higher BMI demonstrated greater step width, greater hip hiking of the paretic lower limb, less paretic limb dorsiflexion at initial contact, and less paretic ankle power at push-off as compared to stroke subjects with a lower BMI and similar level of motor impairment. Further studies are necessary to determine the clinical relevance of these findings with respect to rehabilitation strategies for gait dysfunction in hemiparetic patients with higher BMIs. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  13. Integration of smartphones and webcam for the measure of spatio-temporal gait parameters.

    PubMed

    Barone, V; Maranesi, E; Fioretti, S

    2014-01-01

    A very low cost prototype has been made for the spatial and temporal analysis of human movement using an integrated system of last generation smartphones and a highdefinition webcam, controlled by a laptop. The system can be used to analyze mainly planar motions in non-structured environments. In this paper, the accelerometer signal as captured by the 3D sensor embedded in one smartphone, and the position of colored markers derived by the webcam frames, are used for the computation of spatial-temporal parameters of gait. Accuracy of results is compared with that obtainable by a gold-standard instrumentation. The system is characterized by a very low cost and by a very high level of automation. It has been thought to be used by non-expert users in ambulatory settings.

  14. Gait rehabilitation machines based on programmable footplates.

    PubMed

    Schmidt, Henning; Werner, Cordula; Bernhardt, Rolf; Hesse, Stefan; Krüger, Jörg

    2007-02-09

    Gait restoration is an integral part of rehabilitation of brain lesioned patients. Modern concepts favour a task-specific repetitive approach, i.e. who wants to regain walking has to walk, while tone-inhibiting and gait preparatory manoeuvres had dominated therapy before. Following the first mobilization out of the bed, the wheelchair-bound patient should have the possibility to practise complex gait cycles as soon as possible. Steps in this direction were treadmill training with partial body weight support and most recently gait machines enabling the repetitive training of even surface gait and even of stair climbing. With treadmill training harness-secured and partially relieved wheelchair-mobilised patients could practise up to 1000 steps per session for the first time. Controlled trials in stroke and SCI patients, however, failed to show a superior result when compared to walking exercise on the floor. Most likely explanation was the effort for the therapists, e.g. manually setting the paretic limbs during the swing phase resulting in a too little gait intensity. The next steps were gait machines, either consisting of a powered exoskeleton and a treadmill (Lokomat, AutoAmbulator) or an electromechanical solution with the harness secured patient placed on movable foot plates (Gait Trainer GT I). For the latter, a large multi-centre trial with 155 non-ambulatory stroke patients (DEGAS) revealed a superior gait ability and competence in basic activities of living in the experimental group. The HapticWalker continued the end effector concept of movable foot plates, now fully programmable and equipped with 6 DOF force sensors. This device for the first time enables training of arbitrary walking situations, hence not only the simulation of floor walking but also for example of stair climbing and perturbations. Locomotor therapy is a fascinating new tool in rehabilitation, which is in line with modern principles of motor relearning promoting a task-specific repetitive

  15. Gait rehabilitation machines based on programmable footplates

    PubMed Central

    Schmidt, Henning; Werner, Cordula; Bernhardt, Rolf; Hesse, Stefan; Krüger, Jörg

    2007-01-01

    Background Gait restoration is an integral part of rehabilitation of brain lesioned patients. Modern concepts favour a task-specific repetitive approach, i.e. who wants to regain walking has to walk, while tone-inhibiting and gait preparatory manoeuvres had dominated therapy before. Following the first mobilization out of the bed, the wheelchair-bound patient should have the possibility to practise complex gait cycles as soon as possible. Steps in this direction were treadmill training with partial body weight support and most recently gait machines enabling the repetitive training of even surface gait and even of stair climbing. Results With treadmill training harness-secured and partially relieved wheelchair-mobilised patients could practise up to 1000 steps per session for the first time. Controlled trials in stroke and SCI patients, however, failed to show a superior result when compared to walking exercise on the floor. Most likely explanation was the effort for the therapists, e.g. manually setting the paretic limbs during the swing phase resulting in a too little gait intensity. The next steps were gait machines, either consisting of a powered exoskeleton and a treadmill (Lokomat, AutoAmbulator) or an electromechanical solution with the harness secured patient placed on movable foot plates (Gait Trainer GT I). For the latter, a large multi-centre trial with 155 non-ambulatory stroke patients (DEGAS) revealed a superior gait ability and competence in basic activities of living in the experimental group. The HapticWalker continued the end effector concept of movable foot plates, now fully programmable and equipped with 6 DOF force sensors. This device for the first time enables training of arbitrary walking situations, hence not only the simulation of floor walking but also for example of stair climbing and perturbations. Conclusion Locomotor therapy is a fascinating new tool in rehabilitation, which is in line with modern principles of motor relearning

  16. Comparing electro- and mechano-myographic muscle activation patterns in self-paced pediatric gait.

    PubMed

    Plewa, Katherine; Samadani, Ali; Chau, Tom

    2017-10-01

    Electromyography (EMG) is the standard modality for measuring muscle activity. However, the convenience and availability of low-cost accelerometer-based wearables makes mechanomyography (MMG) an increasingly attractive alternative modality for clinical applications. Literature to date has demonstrated a strong association between EMG and MMG temporal alignment in isometric and isokinetic contractions. However, the EMG-MMG relationship has not been studied in gait. In this study, the concurrence of EMG- and MMG-detected contractions in the tibialis anterior, lateral gastrocnemius, vastus lateralis, and biceps femoris muscles were investigated in children during self-paced gait. Furthermore, the distribution of signal power over the gait cycle was statistically compared between EMG-MMG modalities. With EMG as the reference, muscular contractions were detected based on MMG with balanced accuracies between 88 and 94% for all muscles except the gastrocnemius. MMG signal power differed from that of EMG during certain phases of the gait cycle in all muscles except the biceps femoris. These timing and power distribution differences between the two modalities may in part be related to muscle fascicle length changes that are unique to muscle motion during gait. Our findings suggest that the relationship between EMG and MMG appears to be more complex during gait than in isometric and isokinetic contractions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. On Gait Analysis Estimation Errors Using Force Sensors on a Smart Rollator

    PubMed Central

    Ballesteros, Joaquin; Urdiales, Cristina; Martinez, Antonio B.; van Dieën, Jaap H.

    2016-01-01

    Gait analysis can provide valuable information on a person’s condition and rehabilitation progress. Gait is typically captured using external equipment and/or wearable sensors. These tests are largely constrained to specific controlled environments. In addition, gait analysis often requires experts for calibration, operation and/or to place sensors on volunteers. Alternatively, mobility support devices like rollators can be equipped with onboard sensors to monitor gait parameters, while users perform their Activities of Daily Living. Gait analysis in rollators may use odometry and force sensors in the handlebars. However, force based estimation of gait parameters is less accurate than traditional methods, especially when rollators are not properly used. This paper presents an evaluation of force based gait analysis using a smart rollator on different groups of users to determine when this methodology is applicable. In a second stage, the rollator is used in combination with two lab-based gait analysis systems to assess the rollator estimation error. Our results show that: (i) there is an inverse relation between the variance in the force difference between handlebars and support on the handlebars—related to the user condition—and the estimation error; and (ii) this error is lower than 10% when the variation in the force difference is above 7 N. This lower limit was exceeded by the 95.83% of our challenged volunteers. In conclusion, rollators are useful for gait characterization as long as users really need the device for ambulation. PMID:27834911

  18. On Gait Analysis Estimation Errors Using Force Sensors on a Smart Rollator.

    PubMed

    Ballesteros, Joaquin; Urdiales, Cristina; Martinez, Antonio B; van Dieën, Jaap H

    2016-11-10

    Gait analysis can provide valuable information on a person's condition and rehabilitation progress. Gait is typically captured using external equipment and/or wearable sensors. These tests are largely constrained to specific controlled environments. In addition, gait analysis often requires experts for calibration, operation and/or to place sensors on volunteers. Alternatively, mobility support devices like rollators can be equipped with onboard sensors to monitor gait parameters, while users perform their Activities of Daily Living. Gait analysis in rollators may use odometry and force sensors in the handlebars. However, force based estimation of gait parameters is less accurate than traditional methods, especially when rollators are not properly used. This paper presents an evaluation of force based gait analysis using a smart rollator on different groups of users to determine when this methodology is applicable. In a second stage, the rollator is used in combination with two lab-based gait analysis systems to assess the rollator estimation error. Our results show that: (i) there is an inverse relation between the variance in the force difference between handlebars and support on the handlebars-related to the user condition-and the estimation error; and (ii) this error is lower than 10% when the variation in the force difference is above 7 N. This lower limit was exceeded by the 95.83% of our challenged volunteers. In conclusion, rollators are useful for gait characterization as long as users really need the device for ambulation.

  19. A proof-of-concept study for measuring gait speed, steadiness, and dynamic balance under various footwear conditions outside of the gait laboratory.

    PubMed

    Wrobel, James S; Edgar, Sarah; Cozzetto, Dana; Maskill, James; Peterson, Paul; Najafi, Bijan

    2010-01-01

    This pilot study examined the effect of custom and prefabricated foot orthoses on self-selected walking speed, walking speed variability, and dynamic balance in the mediolateral direction. The gait of four healthy participants was analyzed with a body-worn sensor system across a distance of at least 30 m outside of the gait laboratory. Participants walked at their habitual speed in four conditions: barefoot, regular shoes, prefabricated foot orthoses, and custom foot orthoses. In the custom foot orthoses condition, gait speed was improved on average 13.5% over the barefoot condition and 9.8% over the regular shoe condition. The mediolateral range of motion of center of mass was reduced 55% and 56% compared with the shoes alone and prefabricated foot orthoses conditions, respectively. This may suggest better gait efficiency and lower energy cost with custom foot orthoses. This tendency remained after normalizing center of mass by gait speed, suggesting that irrespective of gait speed, custom foot orthoses improve center of mass motion in the mediolateral direction compared with other footwear conditions. Gait intercycle variability, measured by intercycle coefficient of variation of gait speed, was decreased on average by 25% and 19% compared with the barefoot and shoes-alone conditions, respectively. The decrease in gait unsteadiness after wearing custom foot orthoses may suggest improved proprioception from the increased contact area of custom foot orthoses versus the barefoot condition. These findings may open new avenues for objective assessment of the impact of prescribed footwear on dynamic balance and spatiotemporal parameters of gait and assess gait adaptation after use of custom foot orthoses.

  20. The influence of applying additional weight to the affected leg on gait patterns during aquatic treadmill walking in people poststroke.

    PubMed

    Jung, Taeyou; Lee, Dokyeong; Charalambous, Charalambos; Vrongistinos, Konstantinos

    2010-01-01

    Jung T, Lee D, Charalambous C, Vrongistinos K. The influence of applying additional weight to the affected leg on gait patterns during aquatic treadmill walking in people poststroke. To investigate how the application of additional weights to the affected leg influences gait patterns of people poststroke during aquatic treadmill walking. Comparative gait analysis. University-based aquatic therapy center. Community-dwelling volunteers (n=22) with chronic hemiparesis caused by stroke. Not applicable. Spatiotemporal and kinematic gait parameters. The use of an ankle weight showed an increase in the stance phase percentage of gait cycle (3%, P=.015) when compared with no weight. However, the difference was not significant after a Bonferroni adjustment was applied for a more stringent statistical analysis. No significant differences were found in cadence and stride length. The use of an ankle weight showed a significant decrease of the peak hip flexion (7.9%, P=.001) of the affected limb as compared with no weight condition. This decrease was marked as the reduction of unwanted limb flotation because people poststroke typically show excessive hip flexion of the paretic leg in the late swing phase followed by fluctuating hip movements during aquatic treadmill walking. The frontal and transverse plane hip motions did not show any significant differences but displayed a trend of a decrease in the peak hip abduction during the swing phase with additional weights. The use of additional weight did not alter sagittal plane kinematics of the knee and ankle joints. The use of applied weight on the affected limb can reduce unwanted limb flotation on the paretic side during aquatic treadmill walking. It can also assist the stance stability by increasing the stance phase percentage closer to 60% of gait cycle. Both findings can contribute to the development of more efficient motor patterns in gait training for people poststroke. The use of a cuff weight does not seem to reduce the

  1. Statically vs dynamically balanced gait: Analysis of a robotic exoskeleton compared with a human.

    PubMed

    Barbareschi, Giulia; Richards, Rosie; Thornton, Matt; Carlson, Tom; Holloway, Catherine

    2015-01-01

    In recent years exoskeletons able to replicate human gait have begun to attract growing popularity for both assistive and rehabilitative purposes. Although wearable robots often need the use of external support in order to maintain stability, the REX exoskeleton by REX Bionics is able to self-balance through the whole cycle. However this statically balanced gait presents important differences with the dynamically balanced gait of human subjects. This paper will examine kinematic and kinetic differences between the gait analysis performed on a subject wearing the REX exoskeleton and human gait analysis data as presented in literature. We will also provide an insight on the impact that these differences can have for both rehabilitative and assistive applications.

  2. Challenging Gait Conditions Predict 1-Year Decline in Gait Speed in Older Adults With Apparently Normal Gait

    PubMed Central

    Perera, Subashan; VanSwearingen, Jessie M.; Hile, Elizabeth S.; Wert, David M.; Studenski, Stephanie A.

    2011-01-01

    Background Mobility often is tested under a low challenge condition (ie, over a straight, uncluttered path), which often fails to identify early mobility difficulty. Tests of walking during challenging conditions may uncover mobility difficulty that is not identified with usual gait testing. Objective The purpose of this study was to determine whether gait during challenging conditions predicts decline in gait speed over 1 year in older people with apparently normal gait (ie, gait speed of ≥1.0 m/s). Design This was a prospective cohort study. Methods Seventy-one older adults (mean age=75.9 years) with a usual gait speed of ≥1.0 m/s participated. Gait was tested at baseline under 4 challenging conditions: (1) narrow walk (15 cm wide), (2) stepping over obstacles (15.24 cm [6 in] and 30.48 cm [12 in]), (3) simple walking while talking (WWT), and (4) complex WWT. Usual gait speed was recorded over a 4-m course at baseline and 1 year later. A 1-year change in gait speed was calculated, and participants were classified as declined (decreased ≥0.10 m/s, n=18), stable (changed <0.10 m/s, n=43), or improved (increased ≥0.10 m/s, n=10). Analysis of variance was used to compare challenging condition cost (usual − challenging condition gait speed difference) among the 3 groups. Results Participants who declined in the ensuing year had a greater narrow walk and obstacle walk cost than those who were stable or who improved in gait speed (narrow walk cost=0.43 versus 0.33 versus 0.22 m/s and obstacle walk cost=0.35 versus 0.26 versus 0.13 m/s). Simple and complex WWT cost did not differ among the groups. Limitations The participants who declined in gait speed over time walked the fastest, and those who improved walked the slowest at baseline; thus, the potential contribution of regression to the mean to the findings should not be overlooked. Conclusions In older adults with apparently normal gait, the assessment of gait during challenging conditions appears to uncover

  3. Interrater reliability of videotaped observational gait-analysis assessments.

    PubMed

    Eastlack, M E; Arvidson, J; Snyder-Mackler, L; Danoff, J V; McGarvey, C L

    1991-06-01

    The purpose of this study was to determine the interrater reliability of videotaped observational gait-analysis (VOGA) assessments. Fifty-four licensed physical therapists with varying amounts of clinical experience served as raters. Three patients with rheumatoid arthritis who demonstrated an abnormal gait pattern served as subjects for the videotape. The raters analyzed each patient's most severely involved knee during the four subphases of stance for the kinematic variables of knee flexion and genu valgum. Raters were asked to determine whether these variables were inadequate, normal, or excessive. The temporospatial variables analyzed throughout the entire gait cycle were cadence, step length, stride length, stance time, and step width. Generalized kappa coefficients ranged from .11 to .52. Intraclass correlation coefficients (2,1) and (3,1) were slightly higher. Our results indicate that physical therapists' VOGA assessments are only slightly to moderately reliable and that improved interrater reliability of the assessments of physical therapists utilizing this technique is needed. Our data suggest that there is a need for greater standardization of gait-analysis training.

  4. Climbing favours the tripod gait over alternative faster insect gaits

    NASA Astrophysics Data System (ADS)

    Ramdya, Pavan; Thandiackal, Robin; Cherney, Raphael; Asselborn, Thibault; Benton, Richard; Ijspeert, Auke Jan; Floreano, Dario

    2017-02-01

    To escape danger or catch prey, running vertebrates rely on dynamic gaits with minimal ground contact. By contrast, most insects use a tripod gait that maintains at least three legs on the ground at any given time. One prevailing hypothesis for this difference in fast locomotor strategies is that tripod locomotion allows insects to rapidly navigate three-dimensional terrain. To test this, we computationally discovered fast locomotor gaits for a model based on Drosophila melanogaster. Indeed, the tripod gait emerges to the exclusion of many other possible gaits when optimizing fast upward climbing with leg adhesion. By contrast, novel two-legged bipod gaits are fastest on flat terrain without adhesion in the model and in a hexapod robot. Intriguingly, when adhesive leg structures in real Drosophila are covered, animals exhibit atypical bipod-like leg coordination. We propose that the requirement to climb vertical terrain may drive the prevalence of the tripod gait over faster alternative gaits with minimal ground contact.

  5. Climbing favours the tripod gait over alternative faster insect gaits

    PubMed Central

    Ramdya, Pavan; Thandiackal, Robin; Cherney, Raphael; Asselborn, Thibault; Benton, Richard; Ijspeert, Auke Jan; Floreano, Dario

    2017-01-01

    To escape danger or catch prey, running vertebrates rely on dynamic gaits with minimal ground contact. By contrast, most insects use a tripod gait that maintains at least three legs on the ground at any given time. One prevailing hypothesis for this difference in fast locomotor strategies is that tripod locomotion allows insects to rapidly navigate three-dimensional terrain. To test this, we computationally discovered fast locomotor gaits for a model based on Drosophila melanogaster. Indeed, the tripod gait emerges to the exclusion of many other possible gaits when optimizing fast upward climbing with leg adhesion. By contrast, novel two-legged bipod gaits are fastest on flat terrain without adhesion in the model and in a hexapod robot. Intriguingly, when adhesive leg structures in real Drosophila are covered, animals exhibit atypical bipod-like leg coordination. We propose that the requirement to climb vertical terrain may drive the prevalence of the tripod gait over faster alternative gaits with minimal ground contact. PMID:28211509

  6. Health Monitors for Chronic Disease by Gait Analysis with Mobile Phones

    PubMed Central

    Juen, Joshua; Cheng, Qian; Prieto-Centurion, Valentin; Krishnan, Jerry A.

    2014-01-01

    Abstract We have developed GaitTrack, a phone application to detect health status while the smartphone is carried normally. GaitTrack software monitors walking patterns, using only accelerometers embedded in phones to record spatiotemporal motion, without the need for sensors external to the phone. Our software transforms smartphones into health monitors, using eight parameters of phone motion transformed into body motion by the gait model. GaitTrack is designed to detect health status while the smartphone is carried during normal activities, namely, free-living walking. The current method for assessing free-living walking is medical accelerometers, so we present evidence that mobile phones running our software are more accurate. We then show our gait model is more accurate than medical pedometers for counting steps of patients with chronic disease. Our gait model was evaluated in a pilot study involving 30 patients with chronic lung disease. The six-minute walk test (6MWT) is a major assessment for chronic heart and lung disease, including congestive heart failure and especially chronic obstructive pulmonary disease (COPD), affecting millions of persons. The 6MWT consists of walking back and forth along a measured distance for 6 minutes. The gait model using linear regression performed with 94.13% accuracy in measuring walk distance, compared with the established standard of direct observation. We also evaluated a different statistical model using the same gait parameters to predict health status through lung function. This gait model has high accuracy when applied to demographic cohorts, for example, 89.22% accuracy testing the cohort of 12 female patients with ages 50–64 years. PMID:24694291

  7. A patient-specific EMG-driven neuromuscular model for the potential use of human-inspired gait rehabilitation robots.

    PubMed

    Ma, Ye; Xie, Shengquan; Zhang, Yanxin

    2016-03-01

    A patient-specific electromyography (EMG)-driven neuromuscular model (PENm) is developed for the potential use of human-inspired gait rehabilitation robots. The PENm is modified based on the current EMG-driven models by decreasing the calculation time and ensuring good prediction accuracy. To ensure the calculation efficiency, the PENm is simplified into two EMG channels around one joint with minimal physiological parameters. In addition, a dynamic computation model is developed to achieve real-time calculation. To ensure the calculation accuracy, patient-specific muscle kinematics information, such as the musculotendon lengths and the muscle moment arms during the entire gait cycle, are employed based on the patient-specific musculoskeletal model. Moreover, an improved force-length-velocity relationship is implemented to generate accurate muscle forces. Gait analysis data including kinematics, ground reaction forces, and raw EMG signals from six adolescents at three different speeds were used to evaluate the PENm. The simulation results show that the PENm has the potential to predict accurate joint moment in real-time. The design of advanced human-robot interaction control strategies and human-inspired gait rehabilitation robots can benefit from the application of the human internal state provided by the PENm. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Concurrent prediction of muscle and tibiofemoral contact forces during treadmill gait.

    PubMed

    Guess, Trent M; Stylianou, Antonis P; Kia, Mohammad

    2014-02-01

    Detailed knowledge of knee kinematics and dynamic loading is essential for improving the design and outcomes of surgical procedures, tissue engineering applications, prosthetics design, and rehabilitation. This study used publicly available data provided by the "Grand Challenge Competition to Predict in-vivo Knee Loads" for the 2013 American Society of Mechanical Engineers Summer Bioengineering Conference (Fregly et al., 2012, "Grand Challenge Competition to Predict in vivo Knee Loads," J. Orthop. Res., 30, pp. 503-513) to develop a full body, musculoskeletal model with subject specific right leg geometries that can concurrently predict muscle forces, ligament forces, and knee and ground contact forces. The model includes representation of foot/floor interactions and predicted tibiofemoral joint loads were compared to measured tibial loads for two different cycles of treadmill gait. The model used anthropometric data (height and weight) to scale the joint center locations and mass properties of a generic model and then used subject bone geometries to more accurately position the hip and ankle. The musculoskeletal model included 44 muscles on the right leg, and subject specific geometries were used to create a 12 degrees-of-freedom anatomical right knee that included both patellofemoral and tibiofemoral articulations. Tibiofemoral motion was constrained by deformable contacts defined between the tibial insert and femoral component geometries and by ligaments. Patellofemoral motion was constrained by contact between the patellar button and femoral component geometries and the patellar tendon. Shoe geometries were added to the feet, and shoe motion was constrained by contact between three shoe segments per foot and the treadmill surface. Six-axis springs constrained motion between the feet and shoe segments. Experimental motion capture data provided input to an inverse kinematics stage, and the final forward dynamics simulations tracked joint angle errors for the left

  9. Reliability of four models for clinical gait analysis.

    PubMed

    Kainz, Hans; Graham, David; Edwards, Julie; Walsh, Henry P J; Maine, Sheanna; Boyd, Roslyn N; Lloyd, David G; Modenese, Luca; Carty, Christopher P

    2017-05-01

    Three-dimensional gait analysis (3DGA) has become a common clinical tool for treatment planning in children with cerebral palsy (CP). Many clinical gait laboratories use the conventional gait analysis model (e.g. Plug-in-Gait model), which uses Direct Kinematics (DK) for joint kinematic calculations, whereas, musculoskeletal models, mainly used for research, use Inverse Kinematics (IK). Musculoskeletal IK models have the advantage of enabling additional analyses which might improve the clinical decision-making in children with CP. Before any new model can be used in a clinical setting, its reliability has to be evaluated and compared to a commonly used clinical gait model (e.g. Plug-in-Gait model) which was the purpose of this study. Two testers performed 3DGA in eleven CP and seven typically developing participants on two occasions. Intra- and inter-tester standard deviations (SD) and standard error of measurement (SEM) were used to compare the reliability of two DK models (Plug-in-Gait and a six degrees-of-freedom model solved using Vicon software) and two IK models (two modifications of 'gait2392' solved using OpenSim). All models showed good reliability (mean SEM of 3.0° over all analysed models and joint angles). Variations in joint kinetics were less in typically developed than in CP participants. The modified 'gait2392' model which included all the joint rotations commonly reported in clinical 3DGA, showed reasonable reliable joint kinematic and kinetic estimates, and allows additional musculoskeletal analysis on surgically adjustable parameters, e.g. muscle-tendon lengths, and, therefore, is a suitable model for clinical gait analysis. Copyright © 2017. Published by Elsevier B.V.

  10. Effects of walking speed on asymmetry and bilateral coordination of gait

    PubMed Central

    Plotnik, Meir; Bartsch, Ronny P.; Zeev, Aviva; Giladi, Nir; Hausdorff, Jeffery M.

    2013-01-01

    The mechanisms regulating the bilateral coordination of gait in humans are largely unknown. Our objective was to study how bilateral coordination changes as a result of gait speed modifications during over ground walking. 15 young adults wore force sensitive insoles that measured vertical forces used to determine the timing of the gait cycle events under three walking conditions (i.e., usual-walking, fast and slow). Ground reaction force impact (GRFI) associated with heel-strikes was also quantified, representing the potential contribution of sensory feedback to the regulation of gait. Gait asymmetry (GA) was quantified based on the differences between right and left swing times and the bilateral coordination of gait was assessed using the phase coordination index (PCI), a metric that quantifies the consistency and accuracy of the anti-phase stepping pattern. GA was preserved in the three different gait speeds. PCI was higher (reduced coordination) in the slow gait condition, compared to usual-walking (3.51% vs. 2.47%, respectively, p=0.002), but was not significantly affected in the fast condition. GRFI values were lower in the slow walking as compared to usual-walking and higher in the fast walking condition (p<0.001). Stepwise regression revealed that slowed gait related changes in PCI were not associated with the slowed gait related changes in GRFI. The present findings suggest that left-right anti-phase stepping is similar in normal and fast walking, but altered during slowed walking. This behavior might reflect a relative increase in attention resources required to regulate a slow gait speed, consistent with the possibility that cortical function and supraspinal input influences the bilateral coordination of gait. PMID:23680424

  11. Kinematics gait disorder in men with fibromyalgia.

    PubMed

    Heredia-Jimenez, Jose M; Soto-Hermoso, Victor M

    2014-01-01

    The aim of this study was to assess the kinematics disorder of gait in men with fibromyalgia. We studied 12 male with fibromyalgia and 14 healthy men. Each participant of the study walked five trials along a 18.6-m walkway. Fibromyalgia patients completed a Spanish version of Fibromyalgia Impact Questionnaire. Significant differences between fibromyalgia and control groups were found in velocity, stride length, and cadence. Gait parameters of men affected by fibromyalgia were impaired when compared to those of healthy group due to bradykinesia. According to previous studies to assess gait variables in female patients, the male with fibromyalgia also showed lower values of velocity, cadence, and stride length than healthy group but not reported significant differences in swing, stance, single, or double support phase.

  12. Differential effects of rhythmic auditory stimulation and neurodevelopmental treatment/Bobath on gait patterns in adults with cerebral palsy: a randomized controlled trial.

    PubMed

    Kim, Soo Ji; Kwak, Eunmi E; Park, Eun Sook; Cho, Sung-Rae

    2012-10-01

    To investigate the effects of rhythmic auditory stimulation (RAS) on gait patterns in comparison with changes after neurodevelopmental treatment (NDT/Bobath) in adults with cerebral palsy. A repeated-measures analysis between the pretreatment and posttreatment tests and a comparison study between groups. Human gait analysis laboratory. Twenty-eight cerebral palsy patients with bilateral spasticity participated in this study. The subjects were randomly allocated to either neurodevelopmental treatment (n = 13) or rhythmic auditory stimulation (n = 15). Gait training with rhythmic auditory stimulation or neurodevelopmental treatment was performed three sessions per week for three weeks. Temporal and kinematic data were analysed before and after the intervention. Rhythmic auditory stimulation was provided using a combination of a metronome beat set to the individual's cadence and rhythmic cueing from a live keyboard, while neurodevelopmental treatment was implemented following the traditional method. Temporal data, kinematic parameters and gait deviation index as a measure of overall gait pathology were assessed. Temporal gait measures revealed that rhythmic auditory stimulation significantly increased cadence, walking velocity, stride length, and step length (P < 0.05). Kinematic data demonstrated that anterior tilt of the pelvis and hip flexion during a gait cycle was significantly ameliorated after rhythmic auditory stimulation (P < 0.05). Gait deviation index also showed modest improvement in cerebral palsy patients treated with rhythmic auditory stimulation (P < 0.05). However, neurodevelopmental treatment showed that internal and external rotations of hip joints were significantly improved, whereas rhythmic auditory stimulation showed aggravated maximal internal rotation in the transverse plane (P < 0.05). Gait training with rhythmic auditory stimulation or neurodevelopmental treatment elicited differential effects on gait patterns in adults with cerebral palsy.

  13. Dynamic parameters of three-point crutch gait in female patients after total hip arthroplasty.

    PubMed

    Murawa, Michał; Dworak, Lechosław B; Kabaciński, Jarosław; Syczewska, Małgorzata; Rzepnicka, Agata

    2016-01-01

    Patient recovery after a surgical procedure depends, among other factors, on the amount of the body weight with which patient loads lower limb. Research studies report different results of the degree of body weight with which lower limb is loaded during three-point crutch gait. The aim of this study was to evaluate the level of the ground reaction forces (GRF) during crutch gait used by patients after total hip arthroplasty (THA) in the first week after discharge from the orthopaedic units. Ten female patients diagnosed with primary unilateral coxarthrosis participated in a single measurement session. In order to record kinematic and dynamic variables of this gait pattern motion analysis system was used together with two force plates. The static test of body weight distribution between lower limbs was performed on a dual-top stabilometric plate. The average peak values of loading on the operated (O) limb during mid stance and terminal stance of three-point crutch gait were 64.6% and 64.3% of body weight (BW), respectively, whereas in the case of the nonoperated (NO) limb 103.5%BW and 108.8%BW, respectively. The maximum loads on the crutches were significantly higher (by 9%BW) on the NO side as compared to the O side ( p < 0.05). During the static test, average values of body weight distribution on the O and NO limb were 36%BW and 64%BW, respectively. The patients showed surprisingly similar level of loading on the O limb. The weight bearing on the O limb was lower during static trial than during three-point crutch gait.

  14. A Robust Parameterization of Human Gait Patterns Across Phase-Shifting Perturbations

    PubMed Central

    Villarreal, Dario J.; Poonawala, Hasan A.; Gregg, Robert D.

    2016-01-01

    The phase of human gait is difficult to quantify accurately in the presence of disturbances. In contrast, recent bipedal robots use time-independent controllers relying on a mechanical phase variable to synchronize joint patterns through the gait cycle. This concept has inspired studies to determine if human joint patterns can also be parameterized by a mechanical variable. Although many phase variable candidates have been proposed, it remains unclear which, if any, provide a robust representation of phase for human gait analysis or control. In this paper we analytically derive an ideal phase variable (the hip phase angle) that is provably monotonic and bounded throughout the gait cycle. To examine the robustness of this phase variable, ten able-bodied human subjects walked over a platform that randomly applied phase-shifting perturbations to the stance leg. A statistical analysis found the correlations between nominal and perturbed joint trajectories to be significantly greater when parameterized by the hip phase angle (0.95+) than by time or a different phase variable. The hip phase angle also best parameterized the transient errors about the nominal periodic orbit. Finally, interlimb phasing was best explained by local (ipsilateral) hip phase angles that are synchronized during the double-support period. PMID:27187967

  15. Gait and energy consumption in adolescent idiopathic scoliosis: A literature review.

    PubMed

    Daryabor, Aliyeh; Arazpour, Mokhtar; Sharifi, Guive; Bani, Monireh Ahmadi; Aboutorabi, Atefeh; Golchin, Navid

    2017-04-01

    Adolescent idiopathic scoliosis (AIS) is a progressive growth disease that affects spinal anatomy, mobility, and left-right trunk symmetry. The disease can modify human gait. We aimed to review articles describing the measurement of gait parameters and energy consumption in AIS during walking without any intervention. Literature review. The search strategy was based on the Population Intervention Comparison Outcome method and included all relevant articles published from 1996 to 2015. Articles were searched in MEDLINE via PubMed, Science Direct, Google Scholar, and ISI Web of Knowledge databases. We selected 33 studies investigating the effect of scoliosis deformity on gait parameters and energy expenditure during walking. Most of the studies concluded no significant differences in walking speed, cadence and step width in scoliosis patients and normal participants. However, patients showed decreased hip and pelvic motion, excessive energy cost of walking, stepping pattern asymmetry and ground reaction force asymmetry. We lack consistent evidence of the effect of scoliosis on temporal spatial and kinematic parameters in AIS patients as compared with normal people. However, further research is needed to assess the effect of scoliosis on gait and energy consumption. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Automatic identification of gait events using an instrumented sock

    PubMed Central

    2011-01-01

    Background Textile-based transducers are an emerging technology in which piezo-resistive properties of materials are used to measure an applied strain. By incorporating these sensors into a sock, this technology offers the potential to detect critical events during the stance phase of the gait cycle. This could prove useful in several applications, such as functional electrical stimulation (FES) systems to assist gait. Methods We investigated the output of a knitted resistive strain sensor during walking and sought to determine the degree of similarity between the sensor output and the ankle angle in the sagittal plane. In addition, we investigated whether it would be possible to predict three key gait events, heel strike, heel lift and toe off, with a relatively straight-forward algorithm. This worked by predicting gait events to occur at fixed time offsets from specific peaks in the sensor signal. Results Our results showed that, for all subjects, the sensor output exhibited the same general characteristics as the ankle joint angle. However, there were large between-subjects differences in the degree of similarity between the two curves. Despite this variability, it was possible to accurately predict gait events using a simple algorithm. This algorithm displayed high levels of trial-to-trial repeatability. Conclusions This study demonstrates the potential of using textile-based transducers in future devices that provide active gait assistance. PMID:21619570

  17. Quantification and recognition of parkinsonian gait from monocular video imaging using kernel-based principal component analysis

    PubMed Central

    2011-01-01

    Background The computer-aided identification of specific gait patterns is an important issue in the assessment of Parkinson's disease (PD). In this study, a computer vision-based gait analysis approach is developed to assist the clinical assessments of PD with kernel-based principal component analysis (KPCA). Method Twelve PD patients and twelve healthy adults with no neurological history or motor disorders within the past six months were recruited and separated according to their "Non-PD", "Drug-On", and "Drug-Off" states. The participants were asked to wear light-colored clothing and perform three walking trials through a corridor decorated with a navy curtain at their natural pace. The participants' gait performance during the steady-state walking period was captured by a digital camera for gait analysis. The collected walking image frames were then transformed into binary silhouettes for noise reduction and compression. Using the developed KPCA-based method, the features within the binary silhouettes can be extracted to quantitatively determine the gait cycle time, stride length, walking velocity, and cadence. Results and Discussion The KPCA-based method uses a feature-extraction approach, which was verified to be more effective than traditional image area and principal component analysis (PCA) approaches in classifying "Non-PD" controls and "Drug-Off/On" PD patients. Encouragingly, this method has a high accuracy rate, 80.51%, for recognizing different gaits. Quantitative gait parameters are obtained, and the power spectrums of the patients' gaits are analyzed. We show that that the slow and irregular actions of PD patients during walking tend to transfer some of the power from the main lobe frequency to a lower frequency band. Our results indicate the feasibility of using gait performance to evaluate the motor function of patients with PD. Conclusion This KPCA-based method requires only a digital camera and a decorated corridor setup. The ease of use and

  18. Low Power Shoe Integrated Intelligent Wireless Gait Measurement System

    NASA Astrophysics Data System (ADS)

    Wahab, Y.; Mazalan, M.; Bakar, N. A.; Anuar, A. F.; Zainol, M. Z.; Hamzah, F.

    2014-04-01

    Gait analysis measurement is a method to assess and identify gait events and the measurements of dynamic, motion and pressure parameters involving the lowest part of the body. This significant analysis is widely used in sports, rehabilitation as well as other health diagnostic towards improving the quality of life. This paper presents a new system empowered by Inertia Measurement Unit (IMU), ultrasonic sensors, piezoceramic sensors array, XBee wireless modules and Arduino processing unit. This research focuses on the design and development of a low power ultra-portable shoe integrated wireless intelligent gait measurement using MEMS and recent microelectronic devices for foot clearance, orientation, error correction, gait events and pressure measurement system. It is developed to be cheap, low power, wireless, real time and suitable for real life in-door and out-door environment.

  19. Analysis of gait in rats with olivocerebellar lesions and ability of the nicotinic acetylcholine receptor agonist varenicline to attenuate impairments.

    PubMed

    Lambert, C S; Philpot, R M; Engberg, M E; Johns, B E; Wecker, L

    2015-09-15

    Studies have demonstrated that administration of the neuronal nicotinic receptor agonist varenicline to rats with olivocerebellar lesions attenuates balance deficits on a rotorod and balance beam, but the effects of this drug on gait deficits have not been investigated. To accomplish this, male Sprague-Dawley rats were trained to walk on a motorized treadmill at 25 and 35 cm/s and baseline performance determined; both temporal and spatial gait parameters were analyzed. A principal component analysis (PCA) was used to identify the key components of gait, and the cumulative gait index (CGI) was calculated, representing deviations from prototypical gait patterns. Subsequently, animals either remained as non-lesioned controls or received injections of 3-acetylpyridine (3-AP)/nicotinamide to destroy the climbing fibers innervating Purkinje cells. The gait of the non-lesioned group was assessed weekly to monitor changes in the normal population, while the gait of the lesioned group was assessed 1 week following 3-AP administration, and weekly following the daily administration of saline or varenicline (0.3, 1.0, or 3.0mg free base/kg) for 2 weeks. Non-lesioned animals exhibited a 60-70% increased CGI over time due to increases in temporal gait measures, whereas lesioned animals exhibited a nearly 3-fold increased CGI as a consequence of increases in spatial measures. Following 2 weeks of treatment with the highest dose of varenicline (3.0mg free base/kg), the swing duration of lesioned animals normalized, and stride duration, stride length and step angle in this population did not differ from the non-lesioned population. Thus, varenicline enabled animals to compensate for their impairments and rectify the timing of the gait cycle. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Motor Learning Versus StandardWalking Exercise in Older Adults with Subclinical Gait Dysfunction: A Randomized Clinical Trial

    PubMed Central

    Brach, Jennifer S.; Van Swearingen, Jessie M.; Perera, Subashan; Wert, David M.; Studenski, Stephanie

    2013-01-01

    Background Current exercise recommendationsfocus on endurance and strength, but rarely incorporate principles of motor learning. Motor learning exerciseis designed to address neurological aspects of movement. Motor learning exercise has not been evaluated in older adults with subclinical gait dysfunction. Objectives Tocompare motor learning versus standard exercise on measures of mobility and perceived function and disability. Design Single-blind randomized trial. Setting University research center. Participants Olderadults (n=40), mean age 77.1±6.0 years), who had normal walking speed (≥1.0 m/s) and impaired motor skill (Figure of 8 walk time > 8 s). Interventions The motor learning program (ML) incorporated goal-oriented stepping and walking to promote timing and coordination within the phases of the gait cycle. The standard program (S) employed endurance training by treadmill walking.Both included strength training and were offered twice weekly for one hour for 12 weeks. Measurements Primary outcomes included mobility performance (gait efficiency, motor skill in walking, gait speed, and walking endurance)and secondary outcomes included perceived function and disability (Late Life Function and Disability Instrument). Results 38 of 40 participants completed the trial (ML, n=18; S, n=20). ML improved more than Sin gait speed (0.13 vs. 0.05 m/s, p=0.008) and motor skill (−2.2 vs. −0.89 s, p<0.0001). Both groups improved in walking endurance (28.3 and 22.9m, but did not differ significantly p=0.14). Changes in gait efficiency and perceived function and disability were not different between the groups (p>0.10). Conclusion In older adults with subclinical gait dysfunction, motor learning exercise improved some parameters of mobility performance more than standard exercise. PMID:24219189

  1. Gait pattern alteration by functional sensory substitution in healthy subjects and in diabetic subjects with peripheral neuropathy.

    PubMed

    Walker, S C; Helm, P A; Lavery, L A

    1997-08-01

    To evaluate the ability of diabetic and nondiabetic individuals to learn to use a lower extremity sensory substitution device to cue gait pattern changes. Case-control study. Gait laboratory. Thirty diabetic persons and 20 age- and education-matched nondiabetic controls responded to advertisements for study participation. Participants walked on a treadmill at three speeds (1, 2, and 2.5mph) with auditory sensory feedback to cue ground contact greater than 80% duration of baseline. The variables measured included gait cycle (steps per minute) and number of times per minute that any step during a trial exceeded 80% duration of ground contacted compared with a measured baseline step length for each speed. Persons in both groups were able to rapidly and significantly alter their gait patterns in response to signals from the sensory substitution device, by changing their gait cycles (nondiabetic group, F(17,124) = 5.27, p < .001; diabetic group, F(5,172) = 3.45, p < .001). Post hoc analyses showed early gait cycle modification and error reduction among both groups. The nondiabetic group learned to use the device significantly more quickly than the diabetic group during the slow (1mph, t = 3.57, p < .001) and average (2mph, t = 2.97, p < .05) trials. By the fast (2.5mph) ambulation trial, both groups were performing equally, suggesting a rapid rate of adjustment to the device. No technical failures from gait trainer malfunction occurred during the study. Diabetic persons with neuropathy effectively used lower extremity sensory substitution, and the technology is now available to manufacture a durable, effective lower extremity sensory substitution system.

  2. Portable kit for the assessment of gait parameters in daily telerehabilitation.

    PubMed

    Giansanti, Daniele; Morelli, Sandra; Maccioni, Giovanni; Grigioni, Mauro

    2013-03-01

    When designing a complete process of daily telerehabilitation, it should be borne in mind that patients should be furnished with properly designed methodologies for executing specific motion tasks and the assessment of the relevant parameters. In general, such a process should comprehend three basic elements in both the hospital and the home: (a) instrumented walkways, (b) walking aids or supports, and (c) equipment for the assessment of parameters. The objective, with gait being the focus, of this study was thus to design a simple, portable kit-as an alternative to the complex and expensive instruments currently used-to be easily interfaced or integrated with the instrumented walkways and aids/supports both for self-monitoring while patients are exercising with their own aids and for clinical reporting. The proposed system is a portable kit that furnishes useful parameters with feedback to both the patient and the trainer/therapist. Capable of being integrated with the most common mechanical tools used in motion rehabilitation (handrail, scales, walkways, etc.), it constantly monitors and quantitatively assesses progress in rehabilitation care. It is composed of one step counter, photo-emitter detectors, one central unit for collecting and processing the telemetrically transmitted data, and a software interface. The system has been successfully validated on 16 subjects at the second level of the Tinetti test in a clinical application for both home and the hospital. The portable kit can be used with different rehabilitation tools and on varying ground rugosity. Advantages include (a) very low cost, when compared with optoelectronic solutions or other portable devices, (b) very high accuracy, also for subjects with imbalance problems, compared with other commercial solutions, and (c) integration (compatibility) with any rehabilitative tool.

  3. Improved walking ability and reduced therapeutic stress with an electromechanical gait device.

    PubMed

    Freivogel, Susanna; Schmalohr, Dieter; Mehrholz, Jan

    2009-09-01

    To evaluate the effectiveness of repetitive locomotor training using a newly developed electromechanical gait device compared with treadmill training/gait training with respect to patient's ambulatory motor outcome, necessary personnel resources, and discomfort experienced by therapists and patients. Randomized, controlled, cross-over trial. Sixteen non-ambulatory patients after stroke, severe brain or spinal cord injury sequentially received 2 kinds of gait training. Study intervention A: 20 treatments of locomotor training with an electromechanical gait device; control intervention B: 20 treatments of locomotor training with treadmill or task-oriented gait training. The primary variable was walking ability (Functional Ambulation Category). Secondary variables included gait velocity, Motricity-Index, Rivermead-Mobility-Index, number of therapists needed, and discomfort and effort of patients and therapists during training. Gait ability and the other motor outcome related parameters improved for all patients, but without significant difference between intervention types. However, during intervention A, significantly fewer therapists were needed, and they reported less discomfort and a lower level of effort during training sessions. Locomotor training with or without an electromechanical gait trainer leads to improved gait ability; however, using the electromechanical gait trainer requires less therapeutic assistance, and therapist discomfort is reduced.

  4. Free-living and laboratory gait characteristics in patients with multiple sclerosis

    PubMed Central

    Nair, K. P. S.; Clarke, Alison J.; Van der Meulen, Jill M.; Mazzà, Claudia

    2018-01-01

    Background Wearable sensors offer the potential to bring new knowledge to inform interventions in patients affected by multiple sclerosis (MS) by thoroughly quantifying gait characteristics and gait deficits from prolonged daily living measurements. The aim of this study was to characterise gait in both laboratory and daily life conditions for a group of patients with moderate to severe ambulatory impairment due to MS. To this purpose, algorithms to detect and characterise gait from wearable inertial sensors data were also validated. Methods Fourteen patients with MS were divided into two groups according to their disability level (EDSS 6.5–6.0 and EDSS 5.5–5.0, respectively). They performed both intermittent and continuous walking bouts (WBs) in a gait laboratory wearing waist and shank mounted inertial sensors. An algorithm (W-CWT) to estimate gait events and temporal parameters (mean and variability values) using data recorded from the waist mounted sensor (Dynaport, Mc Roberts) was tested against a reference algorithm (S-REF) based on the shank-worn sensors (OPAL, APDM). Subsequently, the accuracy of another algorithm (W-PAM) to detect and classify WBs was also tested. The validated algorithms were then used to quantify gait characteristics during short (sWB, 5–50 steps), intermediate (iWB, 51–100 steps) and long (lWB, >100 steps) daily living WBs and laboratory walking. Group means were compared using a two-way ANOVA. Results W-CWT compared to S-REF showed good gait event accuracy (0.05–0.10 s absolute error) and was not influenced by disability level. It slightly overestimated stride time in intermittent walking (0.012 s) and overestimated highly variability of temporal parameters in both intermittent (17.5%–58.2%) and continuous walking (11.2%–76.7%). The accuracy of W-PAM was speed-dependent and decreased with increasing disability. The ANOVA analysis showed that patients walked at a slower pace in daily living than in the laboratory. In daily

  5. The effect of a 3-month supervised exercise programme on gait parameters of patients with peripheral arterial disease and intermittent claudication.

    PubMed

    King, Stephanie; Vanicek, Natalie; Mockford, Katherine A; Coughlin, Patrick A

    2012-10-01

    The management of peripheral arterial disease with intermittent claudication includes angioplasty, pharmaceutical therapy, risk factor modification and exercise therapy. Supervised exercise programmes are used sporadically but may improve the distance that an individual with claudication can walk. The purpose of this study was to evaluate the effectiveness of a 3-month supervised exercise programme on improving gait parameters in patients with intermittent claudication. 12 participants were recruited (mean (SD) - age: 67.3 (6.8) years, height: 1.67 (0.09) m, mass: 79.4 (14.0) kg, ankle brachial pressure index: 0.73 (0.17)) from the local vascular unit and enrolled in a supervised exercise programme. Kinematic and kinetic data were collected at the following time points: pain-free walking, initial claudication pain, absolute claudication pain and after a patient-defined rest period. Data were collected before and after the 3-month supervised exercise programme. No significant differences were found in any of the gait parameters post-intervention including pain-free walking speed (P=0.274), peak hip extension (P=0.125), peak ankle plantarflexion (P=0.254), or first vertical ground reaction force peak (P=0.654). No significant gait differences were found across different levels of pain pre- or post-intervention. The lack of improvement post-intervention observed suggests that the current exercise protocol was not tailored to elicit significant improvements in patients with intermittent claudication, specifically. The results indicate that exercise programmes may show improved results post-intervention if they are longer in duration and varied in intensity. Further research into more detailed muscle and biomechanical adaptations is needed to inform exercise programmes specific to this population. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Altering length and velocity feedback during a neuro-musculoskeletal simulation of normal gait contributes to hemiparetic gait characteristics.

    PubMed

    Jansen, Karen; De Groote, Friedl; Aerts, Wouter; De Schutter, Joris; Duysens, Jacques; Jonkers, Ilse

    2014-04-30

    Spasticity is an important complication after stroke, especially in the anti-gravity muscles, i.e. lower limb extensors. However the contribution of hyperexcitable muscle spindle reflex loops to gait impairments after stroke is often disputed. In this study a neuro-musculoskeletal model was developed to investigate the contribution of an increased length and velocity feedback and altered reflex modulation patterns to hemiparetic gait deficits. A musculoskeletal model was extended with a muscle spindle model providing real-time length and velocity feedback of gastrocnemius, soleus, vasti and rectus femoris during a forward dynamic simulation (neural control model). By using a healthy subject's base muscle excitations, in combination with increased feedback gains and altered reflex modulation patterns, the effect on kinematics was simulated. A foot-ground contact model was added to account for the interaction effect between the changed kinematics and the ground. The qualitative effect i.e. the directional effect and the specific gait phases where the effect is present, on the joint kinematics was then compared with hemiparetic gait deviations reported in the literature. Our results show that increased feedback in combination with altered reflex modulation patterns of soleus, vasti and rectus femoris muscle can contribute to excessive ankle plantarflexion/inadequate dorsiflexion, knee hyperextension/inadequate flexion and increased hip extension/inadequate flexion during dedicated gait cycle phases. Increased feedback of gastrocnemius can also contribute to excessive plantarflexion/inadequate dorsiflexion, however in combination with excessive knee and hip flexion. Increased length/velocity feedback can therefore contribute to two types of gait deviations, which are both in accordance with previously reported gait deviations in hemiparetic patients. Furthermore altered modulation patterns, in particular the reduced suppression of the muscle spindle feedback during

  7. DEVELOPMENT OF AN INFLIGHT COUNTERMEASURE TO MITIGATE POSTFLIGHT GAIT DYSFUNCTION

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Mulavara, A. P.; Cohen, H. S.; Richards, J. T.; Miller, C. A.

    2005-01-01

    Locomotion Test (ITLT) and the Functional Mobility Test (FMT). The ITLT characterizes alterations in the integrated function of multiple sensorimotor subsystems responsible for the control of locomotion. This test calls for subjects to walk on a motorized treadmill while we assess changes in dynamic postural stability, head-trunk coordination, short-latency head stabilization responses, dynamic visual acuity, lower limb coordination strategies and gait cycle timing. To make these assessments we measure the following parameters while subjects walk on the treadmill: 1) full body 3-dimensional kinematics using a motion capture system (Motion Analysis Corp., Santa Rosa, CA); 2) the shock-wave transmitted from heel-strike to the head using triaxial accelerometers placed on the tibia and head (Entran, Fairfield, NJ); 3) vertical forces using an instrumented treadmill (Kistler Instrument Corp., Amherst, NY); 4) Dynamic visual acuity using Landolt Cs presented on a laptop computer located 4m from the eyes and 5) Gait cycle timing using foot-switches (Motion Lab Systems, Inc., Baton Rouge, LA) attached to the plantar surface of each shoe at the heel and toe. The FMT evaluates a subject's ability to perform challenging locomotor maneuvers similar to those encountered during an egress from a space vehicle. Subjects step over and duck under obstacles along with negotiating a series of pylons set up on a base of 10 cm thick medium density foam. The dependent measures for the FMT are time to complete the course and the number of obstacles touched. To date, we have collected pre and postflight locomotion data from Expeditions 5-9 who will serve as part of the control group for this study. Preliminary results comparing the recovery rates in gait control sub-systems obtained from the ITLT and FMT performance showed two recovery patterns: 1) a concordant recovery trend between gait control parameters and FMT performance indicating a restitution pattern of recovery and 2) gait controecovery

  8. Development of an Inflight Countermeasure to Mitigate Postflight Gait Dysfunction

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Richards, J. T.; Miller, C. A.; Brady, R.; Warren, L. E.

    2005-01-01

    Locomotion Test (ITLT) and the Functional Mobility Test (FMT). The ITLT characterizes alterations in the integrated function of multiple sensorimotor subsystems responsible for the control of locomotion. This test calls for subjects to walk on a motorized treadmill while we assess changes in dynamic postural stability, head-trunk coordination, short-latency head stabilization responses, dynamic visual acuity, lower limb coordination strategies and gait cycle timing. To make these assessments we measure the following parameters while subjects walk on the treadmill: 1) full body 3-dimensional kinematics using a motion capture system (Motion Analysis Corp., Santa Rosa, CA); 2) the shock-wave transmitted from heel-strike to the head using triaxial accelerometers placed on the tibia and head (Entran, Fairfield, NJ); 3) vertical forces using an instumented treadmill (Kistler Instrument Corp., Amherst, NY); 4) Dynamic visual acuity using Landolt Cs presented on a laptop computer located 4m from the eyes and 5) Gait cycle timing using foot-switches (Motion Lab Systems, Inc., Baton Rouge, LA) attached to the plantar surface of each shoe at the heel and toe. The FMT evaluates s. subject's ability to perform challenging locomotor maneuvers similar to those encountered during an egress from a space vehicle. Subjects step over and duck under obstacles along with negotiating a series of pylons set up on a base of 10 cm thick medium density foam. The dependent measures for the FMT are time to complete the course and the number of obstacles touched. To date, we have collected pre and postflight locomotion data from Expeditions 5-9 who will serve as part of the control group for this study. Preliminary results comparing the recovery rates in gait control sub-systems obtained from the ITLT and FMT performance showed two recovery patterns: 1) a concordant recovery trend between gait control parameters and FMT performance indicating a restitution pattern of recovery and 2) gait controecovery

  9. Gait Characteristics in Adolescents With Multiple Sclerosis.

    PubMed

    Kalron, Alon; Frid, Lior; Menascu, Shay

    2017-03-01

    Multiple sclerosis is a progressive autoimmune disease of the central nervous system. A presentation of multiple sclerosis before age18 years has traditionally been thought to be rare. However, during the past decade, more cases have been reported. We examined gait characteristics in 24 adolescents with multiple sclerosis (12 girls, 12 boys). Mean disease duration was 20.4 (S.D. = 24.9) months and mean age was 15.5 (S.D. = 1.1) years. The mean expanded disability status scale score was 1.7 (S.D. = 0.7) indicating minimal disability. Outcomes were compared with gait and the gait variability index value of healthy age-matched adolescents. Adolescents with multiple sclerosis walked slower with a wider base of support compared with age-matched healthy control subjects. Moreover, the gait variability index was lower in the multiple sclerosis group compared with the values in the healthy adolescents: 85.4 (S.D. = 8.1) versus 96.5 (S.D. = 7.4). We present gait parameters of adolescents with multiple sclerosis. From a clinical standpoint, our data could improve management of walking dysfunction in this relatively young population. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Scrunching: a novel escape gait in planarians

    NASA Astrophysics Data System (ADS)

    Cochet-Escartin, Olivier; Mickolajczyk, Keith J.; Collins, Eva-Maria S.

    2015-10-01

    The ability to escape a predator or other life-threatening situations is central to animal survival. Different species have evolved unique strategies under anatomical and environmental constraints. In this study, we describe a novel musculature-driven escape gait in planarians, ‘scrunching’, which is quantitatively different from other planarian gaits, such as gliding and peristalsis. We show that scrunching is a conserved gait among different flatworm species, underlying its importance as an escape mechanism. We further demonstrate that it can be induced by a variety of physical stimuli, including amputation, high temperature, electric shock and low pH. We discuss the functional basis for scrunching as the preferential gait when gliding is impaired due to a disruption of mucus production. Finally, we show that the key mechanical features of scrunching are adequately captured by a simple biomechanical model that is solely based on experimental data from traction force microscopy and tissue rheology without fit parameters. Together, our results form a complete description of this novel form of planarian locomotion. Because scrunching has distinct dynamics, this gait can serve as a robust behavioral readout for studies of motor neuron and muscular functions in planarians and in particular the restoration of these functions during regeneration.

  11. Computational evaluation of load carriage effects on gait balance stability.

    PubMed

    Mummolo, Carlotta; Park, Sukyung; Mangialardi, Luigi; Kim, Joo H

    2016-01-01

    Evaluating the effects of load carriage on gait balance stability is important in various applications. However, their quantification has not been rigorously addressed in the current literature, partially due to the lack of relevant computational indices. The novel Dynamic Gait Measure (DGM) characterizes gait balance stability by quantifying the relative effects of inertia in terms of zero-moment point, ground projection of center of mass, and time-varying foot support region. In this study, the DGM is formulated in terms of the gait parameters that explicitly reflect the gait strategy of a given walking pattern and is used for computational evaluation of the distinct balance stability of loaded walking. The observed gait adaptations caused by load carriage (decreased single support duration, inertia effects, and step length) result in decreased DGM values (p < 0.0001), which indicate that loaded walking motions are more statically stable compared with the unloaded normal walking. Comparison of the DGM with other common gait stability indices (the maximum Floquet multiplier and the margin of stability) validates the unique characterization capability of the DGM, which is consistently informative of the presence of the added load.

  12. Stimulation of the mesencephalic locomotor region for gait recovery after stroke.

    PubMed

    Fluri, Felix; Malzahn, Uwe; Homola, György A; Schuhmann, Michael K; Kleinschnitz, Christoph; Volkmann, Jens

    2017-11-01

    One-third of all stroke survivors are unable to walk, even after intensive physiotherapy. Thus, other concepts to restore walking are needed. Because electrical stimulation of the mesencephalic locomotor region (MLR) is known to elicit gait movements, this area might be a promising target for restorative neurostimulation in stroke patients with gait disability. The present study aims to delineate the effect of high-frequency stimulation of the MLR (MLR-HFS) on gait impairment in a rodent stroke model. Male Wistar rats underwent photothrombotic stroke of the right sensorimotor cortex and chronic implantation of a stimulating electrode into the right MLR. Gait was assessed using clinical scoring of the beam-walking test and video-kinematic analysis (CatWalk) at baseline and on days 3 and 4 after experimental stroke with and without MLR-HFS. Kinematic analysis revealed significant changes in several dynamic and static gait parameters resulting in overall reduced gait velocity. All rats exhibited major coordination deficits during the beam-walking challenge and were unable to cross the beam. Simultaneous to the onset of MLR-HFS, a significantly higher walking speed and improvements in several dynamic gait parameters were detected by the CatWalk system. Rats regained the ability to cross the beam unassisted, showing a reduced number of paw slips and misses. MLR-HFS can improve disordered locomotor function in a rodent stroke model. It may act by shielding brainstem and spinal locomotor centers from abnormal cortical input after stroke, thus allowing for compensatory and independent action of these circuits. Ann Neurol 2017;82:828-840. © 2017 American Neurological Association.

  13. Extensive Corrective Fixation Surgeries for Adult Spinal Deformity Improve Posture and Lower Extremity Kinematics During Gait.

    PubMed

    Arima, Hideyuki; Yamato, Yu; Hasegawa, Tomohiko; Kobayashi, Sho; Yoshida, Go; Yasuda, Tatsuya; Banno, Tomohiro; Oe, Shin; Mihara, Yuki; Togawa, Daisuke; Matsuyama, Yukihiro

    2017-10-01

    Longitudinal cohort. The present study aimed to document changes in posture and lower extremity kinematics during gait in patients with adult spinal deformity (ASD) after extensive corrective surgery. Standing radiographic parameters are typically used to evaluate patients with ASD. Previously, preoperative walking and standing posture discrepancy were reported in patients with ASD. We did not include comparison between before and after surgery. Therefore, we thought that pre- and postoperative evaluations for patients with ASD should include gait analysis. Thirty-nine patients with ASD (5 men, 34 women; mean age, 71.0 ± 6.1) who underwent posterior corrective fixation surgeries from the thoracic spine to the pelvis were included. A 4-m walk was recorded and analyzed. Sagittal balance while walking was calculated as the angle between the plumb line on the side and the line connecting the greater trochanter and pinna while walking (i.e., the gait-trunk tilt angle [GTA]). We measured maximum knee extension angle during one gait cycle, step length (cm), and walking speed (m/min). Radiographic parameters were also measured. The mean GTA and the mean maximum knee extension angle significantly improved from 13.4° to 6.4°, and -13.3° to -9.4°(P < 0.001 and P = 0.006), respectively. The mean step length improved from 40.4 to 43.1 cm (P = 0.049), but there was no significant change in walking speed (38.4 to 41.5 m/min, P = 0.105). Postoperative GTA, maximum knee extension angle and step length correlated with postoperative pelvic incidence minus lumbar lordosis (r = 0.324, P = 0.044; r = -0.317, P = 0.049; r = -0.416, P = 0.008, respectively). Our results suggest that postoperative posture, maximum knee extension angle, and step length during gait in patients with ASD improved corresponding to how much correction of the sagittal spinal deformity was achieved. 3.

  14. Muscle Activation during Gait in Children with Duchenne Muscular Dystrophy.

    PubMed

    Ropars, Juliette; Lempereur, Mathieu; Vuillerot, Carole; Tiffreau, Vincent; Peudenier, Sylviane; Cuisset, Jean-Marie; Pereon, Yann; Leboeuf, Fabien; Delporte, Ludovic; Delpierre, Yannick; Gross, Raphaël; Brochard, Sylvain

    2016-01-01

    The aim of this prospective study was to investigate changes in muscle activity during gait in children with Duchenne muscular Dystrophy (DMD). Dynamic surface electromyography recordings (EMGs) of 16 children with DMD and pathological gait were compared with those of 15 control children. The activity of the rectus femoris (RF), vastus lateralis (VL), medial hamstrings (HS), tibialis anterior (TA) and gastrocnemius soleus (GAS) muscles was recorded and analysed quantitatively and qualitatively. The overall muscle activity in the children with DMD was significantly different from that of the control group. Percentage activation amplitudes of RF, HS and TA were greater throughout the gait cycle in the children with DMD and the timing of GAS activity differed from the control children. Significantly greater muscle coactivation was found in the children with DMD. There were no significant differences between sides. Since the motor command is normal in DMD, the hyper-activity and co-contractions likely compensate for gait instability and muscle weakness, however may have negative consequences on the muscles and may increase the energy cost of gait. Simple rehabilitative strategies such as targeted physical therapies may improve stability and thus the pattern of muscle activity.

  15. How to measure responses of the knee to lateral perturbations during gait? A proof-of-principle for quantification of knee instability.

    PubMed

    van den Noort, Josien C; Sloot, Lizeth H; Bruijn, Sjoerd M; Harlaar, Jaap

    2017-08-16

    Knee instability is a major problem in patients with anterior cruciate ligament injury or knee osteoarthritis. A valid and clinically meaningful measure for functional knee instability is lacking. The concept of the gait sensitivity norm, the normalized perturbation response of a walking system to external perturbations, could be a sensible way to quantify knee instability. The aim of this study is to explore the feasibility of this concept for measurement of knee responses, using controlled external perturbations during walking in healthy subjects. Nine young healthy participants walked on a treadmill, while three dimensional kinematics were measured. Sudden lateral translations of the treadmill were applied at five different intensities during stance. Right knee kinematic responses and spatio-temporal parameters were tracked for the perturbed stride and following four cycles, to calculate perturbation response and gait sensitivity norm values (i.e. response/perturbation) in various ways. The perturbation response values in terms of knee flexion and abduction increased with perturbation intensity and decreased with an increased number of steps after perturbation. For flexion and ab/adduction during midswing, the gait sensitivity norm values were shown to be constant over perturbation intensities, demonstrating the potential of the gait sensitivity norm as a robust measure of knee responses to perturbations. These results show the feasibility of using the gait sensitivity norm concept for certain gait indicators based on kinematics of the knee, as a measure of responses during perturbed gait. The current findings in healthy subjects could serve as reference-data to quantify pathological knee instability. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Comparison of the Classifier Oriented Gait Score and the Gait Profile Score based on imitated gait impairments.

    PubMed

    Christian, Josef; Kröll, Josef; Schwameder, Hermann

    2017-06-01

    Common summary measures of gait quality such as the Gait Profile Score (GPS) are based on the principle of measuring a distance from the mean pattern of a healthy reference group in a gait pattern vector space. The recently introduced Classifier Oriented Gait Score (COGS) is a pathology specific score that measures this distance in a unique direction, which is indicated by a linear classifier. This approach has potentially improved the discriminatory power to detect subtle changes in gait patterns but does not incorporate a profile of interpretable sub-scores like the GPS. The main aims of this study were to extend the COGS by decomposing it into interpretable sub-scores as realized in the GPS and to compare the discriminative power of the GPS and COGS. Two types of gait impairments were imitated to enable a high level of control of the gait patterns. Imitated impairments were realized by restricting knee extension and inducing leg length discrepancy. The results showed increased discriminatory power of the COGS for differentiating diverse levels of impairment. Comparison of the GPS and COGS sub-scores and their ability to indicate changes in specific variables supports the validity of both scores. The COGS is an overall measure of gait quality with increased power to detect subtle changes in gait patterns and might be well suited for tracing the effect of a therapeutic treatment over time. The newly introduced sub-scores improved the interpretability of the COGS, which is helpful for practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Gait deviations in Duchenne muscular dystrophy-Part 2. Statistical non-parametric mapping to analyze gait deviations in children with Duchenne muscular dystrophy.

    PubMed

    Goudriaan, Marije; Van den Hauwe, Marleen; Simon-Martinez, Cristina; Huenaerts, Catherine; Molenaers, Guy; Goemans, Nathalie; Desloovere, Kaat

    2018-04-30

    Prolonged ambulation is considered important in children with Duchenne muscular dystrophy (DMD). However, previous studies analyzing DMD gait were sensitive to false positive outcomes, caused by uncorrected multiple comparisons, regional focus bias, and inter-component covariance bias. Also, while muscle weakness is often suggested to be the main cause for the altered gait pattern in DMD, this was never verified. Our research question was twofold: 1) are we able to confirm the sagittal kinematic and kinetic gait alterations described in a previous review with statistical non-parametric mapping (SnPM)? And 2) are these gait deviations related to lower limb weakness? We compared gait kinematics and kinetics of 15 children with DMD and 15 typical developing (TD) children (5-17 years), with a two sample Hotelling's T 2 test and post-hoc two-tailed, two-sample t-test. We used canonical correlation analyses to study the relationship between weakness and altered gait parameters. For all analyses, α-level was corrected for multiple comparisons, resulting in α = 0.005. We only found one of the previously reported kinematic deviations: the children with DMD had an increased knee flexion angle during swing (p = 0.0006). Observed gait deviations that were not reported in the review were an increased hip flexion angle during stance (p = 0.0009) and swing (p = 0.0001), altered combined knee and ankle torques (p = 0.0002), and decreased power absorption during stance (p = 0.0001). No relationships between weakness and these gait deviations were found. We were not able to replicate the gait deviations in DMD previously reported in literature, thus DMD gait remains undefined. Further, weakness does not seem to be linearly related to altered gait features. The progressive nature of the disease requires larger study populations and longitudinal analyses to gain more insight into DMD gait and its underlying causes. Copyright © 2018 Elsevier B.V. All rights

  18. Objective assessment of motor fatigue in multiple sclerosis using kinematic gait analysis: a pilot study

    PubMed Central

    2011-01-01

    Background Fatigue is a frequent and serious symptom in patients with Multiple Sclerosis (MS). However, to date there are only few methods for the objective assessment of fatigue. The aim of this study was to develop a method for the objective assessment of motor fatigue using kinematic gait analysis based on treadmill walking and an infrared-guided system. Patients and methods Fourteen patients with clinically definite MS participated in this study. Fatigue was defined according to the Fatigue Scale for Motor and Cognition (FSMC). Patients underwent a physical exertion test involving walking at their pre-determined patient-specific preferred walking speed until they reached complete exhaustion. Gait was recorded using a video camera, a three line-scanning camera system with 11 infrared sensors. Step length, width and height, maximum circumduction with the right and left leg, maximum knee flexion angle of the right and left leg, and trunk sway were measured and compared using paired t-tests (α = 0.005). In addition, variability in these parameters during one-minute intervals was examined. The fatigue index was defined as the number of significant mean and SD changes from the beginning to the end of the exertion test relative to the total number of gait kinematic parameters. Results Clearly, for some patients the mean gait parameters were more affected than the variability of their movements while other patients had smaller differences in mean gait parameters with greater increases in variability. Finally, for other patients gait changes with physical exertion manifested both in changes in mean gait parameters and in altered variability. The variability and fatigue indices correlated significantly with the motoric but not with the cognitive dimension of the FSMC score (R = -0.602 and R = -0.592, respectively; P < 0.026). Conclusions Changes in gait patterns following a physical exertion test in patients with MS suffering from motor fatigue can be measured

  19. Gait disorders in patients with fibromyalgia.

    PubMed

    Auvinet, Bernard; Bileckot, Richard; Alix, Anne-Sophie; Chaleil, Denis; Barrey, Eric

    2006-10-01

    The objective of this study was to compare gait in patients with fibromyalgia and in matched controls. Measurements must be obtained in patients with fibromyalgia, as the evaluation scales for this disorder are semi-quantitative. We used a patented gait analysis system (Locometrix Centaure Metrix, France) developed by the French National Institute for Agricultural Research. Relaxed walking was evaluated in 14 women (mean age 50+/-5 years; mean height 162+/-5 cm; and mean body weight 68+/-13 kg) meeting American College of Rheumatology criteria for fibromyalgia and in 14 controls matched on sex, age, height, and body weight. Gait during stable walking was severely altered in the patients. Walking speed was significantly diminished (P<0.001) as a result of reductions in stride length (P<0.001) and cycle frequency (P<0.001). The resulting bradykinesia (P<0.001) was the best factor for separating the two groups. Regularity was affected in the patients (P<0.01); this variable is interesting because it is independent of age and sex in healthy, active adults. Measuring the variables that characterize relaxed walking provides useful quantitative data in patients with fibromyalgia.

  20. FreeWalker: a smart insole for longitudinal gait analysis.

    PubMed

    Wang, Baitong; Rajput, Kuldeep Singh; Tam, Wing-Kin; Tung, Anthony K H; Yang, Zhi

    2015-08-01

    Gait analysis is an important diagnostic measure to investigate the pattern of walking. Traditional gait analysis is generally carried out in a gait lab, with equipped force and body tracking sensors, which needs a trained medical professional to interpret the results. This procedure is tedious, expensive, and unreliable and makes it difficult to track the progress across multiple visits. In this paper, we present a smart insole called FreeWalker, which provides quantitative gait analysis outside the confinement of traditional lab, at low- cost. The insole consists of eight pressure sensors and two motion tracking sensors, i.e. 3-axis accelerometer and 3-axis gyroscope. This enables measurement of under-foot pressure distribution and motion sequences in real-time. The insole is enabled with onboard SD card as well as wireless data transmission, which help in continuous gait-cycle analysis. The data is then sent to a gateway, for analysis and interpretation of data, using a user interface where gait features are graphically displayed. We also present validation result of a subject's left foot, who was asked to perform a specific task. Experiment results show that we could achieve a data-sampling rate of over 1 KHz, transmitting data up to a distance of 20 meter and maintain a battery life of around 24 hours. Taking advantage of these features, FreeWalker can be used in various applications, like medical diagnosis, rehabilitation, sports and entertainment.

  1. Towards a Passive Low-Cost In-Home Gait Assessment System for Older Adults

    PubMed Central

    Wang, Fang; Stone, Erik; Skubic, Marjorie; Keller, James M.; Abbott, Carmen; Rantz, Marilyn

    2013-01-01

    In this paper, we propose a webcam-based system for in-home gait assessment of older adults. A methodology has been developed to extract gait parameters including walking speed, step time and step length from a three-dimensional voxel reconstruction, which is built from two calibrated webcam views. The gait parameters are validated with a GAITRite mat and a Vicon motion capture system in the lab with 13 participants and 44 tests, and again with GAITRite for 8 older adults in senior housing. An excellent agreement with intra-class correlation coefficients of 0.99 and repeatability coefficients between 0.7% and 6.6% was found for walking speed, step time and step length given the limitation of frame rate and voxel resolution. The system was further tested with 10 seniors in a scripted scenario representing everyday activities in an unstructured environment. The system results demonstrate the capability of being used as a daily gait assessment tool for fall risk assessment and other medical applications. Furthermore, we found that residents displayed different gait patterns during their clinical GAITRite tests compared to the realistic scenario, namely a mean increase of 21% in walking speed, a mean decrease of 12% in step time, and a mean increase of 6% in step length. These findings provide support for continuous gait assessment in the home for capturing habitual gait. PMID:24235111

  2. Driving electromechanically assisted Gait Trainer for people with stroke.

    PubMed

    Iosa, Marco; Morone, Giovanni; Bragoni, Maura; De Angelis, Domenico; Venturiero, Vincenzo; Coiro, Paola; Pratesi, Luca; Paolucci, Stefano

    2011-01-01

    Electromechanically assisted gait training is a promising task-oriented approach for gait restoration, especially for people with subacute stroke. However, few guidelines are available for selecting the parameter values of the electromechanical Gait Trainer (GT) (Reha-Stim; Berlin, Germany) and none is tailored to a patient's motor capacity. We assessed 342 GT sessions performed by 20 people with stroke who were stratified by Functional Ambulatory Category. In the first GT session of all patients, the body-weight support (BWS) required was higher than that reported in the literature. In further sessions, we noted a slow reduction of BWS and a fast increment of walking speed for the most-affected patients. Inverse trends were observed for the less-affected patients. In all the patients, the heart rate increment was about 20 beats per minute, even for sessions in which the number of strides performed was up to 500. In addition, the effective BWS measured during GT sessions was different from that initially selected by the physiotherapist. This difference depended mainly on the position of the GT platforms during selection. Finally, harness acceleration in the anteroposterior direction proved to be higher in patients with stroke than in nondisabled subjects. Our findings are an initial step toward scientifically selecting parameters in electromechanically assisted gait training.

  3. Metronome Cueing of Walking Reduces Gait Variability after a Cerebellar Stroke.

    PubMed

    Wright, Rachel L; Bevins, Joseph W; Pratt, David; Sackley, Catherine M; Wing, Alan M

    2016-01-01

    Cerebellar stroke typically results in increased variability during walking. Previous research has suggested that auditory cueing reduces excessive variability in conditions such as Parkinson's disease and post-stroke hemiparesis. The aim of this case report was to investigate whether the use of a metronome cue during walking could reduce excessive variability in gait parameters after a cerebellar stroke. An elderly female with a history of cerebellar stroke and recurrent falling undertook three standard gait trials and three gait trials with an auditory metronome. A Vicon system was used to collect 3-D marker trajectory data. The coefficient of variation was calculated for temporal and spatial gait parameters. SDs of the joint angles were calculated and used to give a measure of joint kinematic variability. Step time, stance time, and double support time variability were reduced with metronome cueing. Variability in the sagittal hip, knee, and ankle angles were reduced to normal values when walking to the metronome. In summary, metronome cueing resulted in a decrease in variability for step, stance, and double support times and joint kinematics. Further research is needed to establish whether a metronome may be useful in gait rehabilitation after cerebellar stroke and whether this leads to a decreased risk of falling.

  4. Metronome Cueing of Walking Reduces Gait Variability after a Cerebellar Stroke

    PubMed Central

    Wright, Rachel L.; Bevins, Joseph W.; Pratt, David; Sackley, Catherine M.; Wing, Alan M.

    2016-01-01

    Cerebellar stroke typically results in increased variability during walking. Previous research has suggested that auditory cueing reduces excessive variability in conditions such as Parkinson’s disease and post-stroke hemiparesis. The aim of this case report was to investigate whether the use of a metronome cue during walking could reduce excessive variability in gait parameters after a cerebellar stroke. An elderly female with a history of cerebellar stroke and recurrent falling undertook three standard gait trials and three gait trials with an auditory metronome. A Vicon system was used to collect 3-D marker trajectory data. The coefficient of variation was calculated for temporal and spatial gait parameters. SDs of the joint angles were calculated and used to give a measure of joint kinematic variability. Step time, stance time, and double support time variability were reduced with metronome cueing. Variability in the sagittal hip, knee, and ankle angles were reduced to normal values when walking to the metronome. In summary, metronome cueing resulted in a decrease in variability for step, stance, and double support times and joint kinematics. Further research is needed to establish whether a metronome may be useful in gait rehabilitation after cerebellar stroke and whether this leads to a decreased risk of falling. PMID:27313563

  5. Quantitative method for gait pattern detection based on fiber Bragg grating sensors

    NASA Astrophysics Data System (ADS)

    Ding, Lei; Tong, Xinglin; Yu, Lie

    2017-03-01

    This paper presents a method that uses fiber Bragg grating (FBG) sensors to distinguish the temporal gait patterns in gait cycles. Unlike most conventional methods that focus on electronic sensors to collect those physical quantities (i.e., strains, forces, pressure, displacements, velocity, and accelerations), the proposed method utilizes the backreflected peak wavelength from FBG sensors to describe the motion characteristics in human walking. Specifically, the FBG sensors are sensitive to external strain with the result that their backreflected peak wavelength will be shifted according to the extent of the influence of external strain. Therefore, when subjects walk in different gait patterns, the strains on FBG sensors will be different such that the magnitude of the backreflected peak wavelength varies. To test the reliability of the FBG sensor platform for gait pattern detection, the gold standard method using force-sensitive resistors (FSRs) for defining gait patterns is introduced as a reference platform. The reliability of the FBG sensor platform is determined by comparing the detection results between the FBG sensors and FSRs platforms. The experimental results show that the FBG sensor platform is reliable in gait pattern detection and gains high reliability when compared with the reference platform.

  6. Improvement in gait following combined ankle and subtalar arthrodesis.

    PubMed

    Tenenbaum, Shay; Coleman, Scott C; Brodsky, James W

    2014-11-19

    This study assessed the hypothesis that arthrodesis of both the ankle and the hindfoot joints produces an objective improvement of function as measured by gait analysis of patients with severe ankle and hindfoot arthritis. Twenty-one patients with severe ankle and hindfoot arthritis who underwent unilateral tibiotalocalcaneal arthrodesis with an intramedullary nail were prospectively studied with three-dimensional (3D) gait analysis at a minimum of one year postoperatively. The mean age at the time of the operation was fifty-nine years, and the mean duration of follow-up was seventeen months (range, twelve to thirty-one months). Temporospatial measurements included cadence, step length, walking velocity, and total support time. The kinematic parameters were sagittal plane motion of the ankle, knee, and hip. The kinetic parameters were sagittal plane ankle power and moment and hip power. Symmetry of gait was analyzed by comparing the step lengths on the affected and unaffected sides. There was significant improvement in multiple parameters of postoperative gait as compared with the patients' own preoperative function. Temporospatial data showed significant increases in cadence (p = 0.03) and walking speed (p = 0.001) and decreased total support time (p = 0.02). Kinematic results showed that sagittal plane ankle motion had decreased, from 13.2° preoperatively to 10.2° postoperatively, in the operatively treated limb (p = 0.02), and increased from 22.2° to 24.1° (p = 0.01) in the contralateral limb. Hip motion on the affected side increased from 39° to 43° (p = 0.007), and knee motion increased from 56° to 60° (p = 0.054). Kinetic results showed significant increases in ankle moment (p < 0.0001) of the operatively treated limb, ankle power of the contralateral limb (p = 0.009), and hip power on the affected side (p = 0.005) postoperatively. There was a significant improvement in gait symmetry (p = 0.01). There was a small loss of sagittal plane motion in the

  7. Implementation of an iPhone as a wireless accelerometer for quantifying gait characteristics.

    PubMed

    Lemoyne, Robert; Mastroianni, Timothy; Cozza, Michael; Coroian, Cristian; Grundfest, Warren

    2010-01-01

    The capacity to quantify and evaluate gait beyond the general confines of a clinical environment under effectively autonomous conditions may alleviate rampant strain on limited and highly specialized medical resources. An iPhone consists of a three dimensional accelerometer subsystem with highly robust and scalable software applications. With the synthesis of the integral iPhone features, an iPhone application, which constitutes a wireless accelerometer system for gait quantification and analysis, has been tested and evaluated in an autonomous environment. The acquired gait cycle data was transmitted wireless and through email for subsequent post-processing in a location remote to the location where the experiment was conducted. The iPhone application functioning as a wireless accelerometer for the acquisition of gait characteristics has demonstrated sufficient accuracy and consistency.

  8. Acetabular cartilage defects cause altered hip and knee joint coordination variability during gait.

    PubMed

    Samaan, Michael A; Teng, Hsiang-Ling; Kumar, Deepak; Lee, Sonia; Link, Thomas M; Majumdar, Sharmila; Souza, Richard B

    2015-12-01

    Patients with acetabular cartilage defects reported increased pain and disability compared to those without acetabular cartilage defects. The specific effects of acetabular cartilage defects on lower extremity coordination patterns are unclear. The purpose of this study was to determine hip and knee joint coordination variability during gait in those with and without acetabular cartilage defects. A combined approach, consisting of a semi-quantitative MRI-based quantification method and vector coding, was used to assess hip and knee joint coordination variability during gait in those with and without acetabular cartilage lesions. The coordination variability of the hip flexion-extension/knee rotation, hip abduction-adduction/knee rotation, and hip rotation/knee rotation joint couplings were reduced in the acetabular lesion group compared to the control group during loading response of the gait cycle. The lesion group demonstrated increased variability in the hip flexion-extension/knee rotation and hip abduction-adduction/knee rotation joint couplings, compared to the control group, during the terminal stance/pre-swing phase of gait. Reduced variability during loading response in the lesion group may suggest reduced movement strategies and a possible compensation mechanism for lower extremity instability during this phase of the gait cycle. During terminal stance/pre-swing, a larger variability in the lesion group may suggest increased movement strategies and represent a compensation or pain avoidance mechanism caused by the load applied to the hip joint. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Can FES-Augmented Active Cycling Training Improve Locomotion in Post-Acute Elderly Stroke Patients?

    PubMed

    Peri, Elisabetta; Ambrosini, Emilia; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Nava, Claudia; Longoni, Valentina; Monticone, Marco; Ferrante, Simona

    2016-06-13

    Recent studies advocated the use of active cycling coupled with functional electrical stimulation to induce neuroplasticity and enhance functional improvements in stroke adult patients. The aim of this work was to evaluate whether the benefits induced by such a treatment are superior to standard physiotherapy. A single-blinded randomized controlled trial has been performed on post-acute elderly stroke patients. Patients underwent FES-augmented cycling training combined with voluntary pedaling or standard physiotherapy. The intervention consisted of fifteen 30-minutes sessions carried out within 3 weeks. Patients were evaluated before and after training, through functional scales, gait analysis and a voluntary pedaling test. Results were compared with an age-matched healthy group. Sixteen patients completed the training. After treatment, a general improvement of all clinical scales was obtained for both groups. Only the mechanical efficiency highlighted a group effect in favor of the experimental group. Although a group effect was not found for any other cycling or gait parameters, the experimental group showed a higher percentage of change with respect to the control group (e.g. the gait velocity was improved of 35.4% and 25.4% respectively, and its variation over time was higher than minimal clinical difference for the experimental group only). This trend suggests that differences in terms of motor recovery between the two groups may be achieved increasing the training dose. In conclusion, this study, although preliminary, showed that FES-augmented active cycling training seems to be effective in improving cycling and walking ability in post-acute elderly stroke patients. A higher sample size is required to confirm results.

  10. Biofeedback for robotic gait rehabilitation.

    PubMed

    Lünenburger, Lars; Colombo, Gery; Riener, Robert

    2007-01-23

    Development and increasing acceptance of rehabilitation robots as well as advances in technology allow new forms of therapy for patients with neurological disorders. Robot-assisted gait therapy can increase the training duration and the intensity for the patients while reducing the physical strain for the therapist. Optimal training effects during gait therapy generally depend on appropriate feedback about performance. Compared to manual treadmill therapy, there is a loss of physical interaction between therapist and patient with robotic gait retraining. Thus, it is difficult for the therapist to assess the necessary feedback and instructions. The aim of this study was to define a biofeedback system for a gait training robot and test its usability in subjects without neurological disorders. To provide an overview of biofeedback and motivation methods applied in gait rehabilitation, previous publications and results from our own research are reviewed. A biofeedback method is presented showing how a rehabilitation robot can assess the patients' performance and deliver augmented feedback. For validation, three subjects without neurological disorders walked in a rehabilitation robot for treadmill training. Several training parameters, such as body weight support and treadmill speed, were varied to assess the robustness of the biofeedback calculation to confounding factors. The biofeedback values correlated well with the different activity levels of the subjects. Changes in body weight support and treadmill velocity had a minor effect on the biofeedback values. The synchronization of the robot and the treadmill affected the biofeedback values describing the stance phase. Robot-aided assessment and feedback can extend and improve robot-aided training devices. The presented method estimates the patients' gait performance with the use of the robot's existing sensors, and displays the resulting biofeedback values to the patients and therapists. The therapists can adapt the

  11. Biofeedback for robotic gait rehabilitation

    PubMed Central

    Lünenburger, Lars; Colombo, Gery; Riener, Robert

    2007-01-01

    Background Development and increasing acceptance of rehabilitation robots as well as advances in technology allow new forms of therapy for patients with neurological disorders. Robot-assisted gait therapy can increase the training duration and the intensity for the patients while reducing the physical strain for the therapist. Optimal training effects during gait therapy generally depend on appropriate feedback about performance. Compared to manual treadmill therapy, there is a loss of physical interaction between therapist and patient with robotic gait retraining. Thus, it is difficult for the therapist to assess the necessary feedback and instructions. The aim of this study was to define a biofeedback system for a gait training robot and test its usability in subjects without neurological disorders. Methods To provide an overview of biofeedback and motivation methods applied in gait rehabilitation, previous publications and results from our own research are reviewed. A biofeedback method is presented showing how a rehabilitation robot can assess the patients' performance and deliver augmented feedback. For validation, three subjects without neurological disorders walked in a rehabilitation robot for treadmill training. Several training parameters, such as body weight support and treadmill speed, were varied to assess the robustness of the biofeedback calculation to confounding factors. Results The biofeedback values correlated well with the different activity levels of the subjects. Changes in body weight support and treadmill velocity had a minor effect on the biofeedback values. The synchronization of the robot and the treadmill affected the biofeedback values describing the stance phase. Conclusion Robot-aided assessment and feedback can extend and improve robot-aided training devices. The presented method estimates the patients' gait performance with the use of the robot's existing sensors, and displays the resulting biofeedback values to the patients and

  12. Gait patterns in hemiplegic patients with equinus foot deformity.

    PubMed

    Manca, M; Ferraresi, G; Cosma, M; Cavazzuti, L; Morelli, M; Benedetti, M G

    2014-01-01

    Equinus deformity of the foot is a common feature of hemiplegia, which impairs the gait pattern of patients. The aim of the present study was to explore the role of ankle-foot deformity in gait impairment. A hierarchical cluster analysis was used to classify the gait patterns of 49 chronic hemiplegic patients with equinus deformity of the foot, based on temporal-distance parameters and joint kinematic measures obtained by an innovative protocol for motion assessment in the sagittal, frontal, and transverse planes, synthesized by parametrical analysis. Cluster analysis identified five subgroups of patients with homogenous levels of dysfunction during gait. Specific joint kinematic abnormalities were found, according to the speed of progression in each cluster. Patients with faster walking were those with less ankle-foot complex impairment or with reduced range of motion of ankle-foot complex, that is with a stiff ankle-foot complex. Slow walking was typical of patients with ankle-foot complex instability (i.e., larger motion in all the planes), severe equinus and hip internal rotation pattern, and patients with hip external rotation pattern. Clustering of gait patterns in these patients is helpful for a better understanding of dysfunction during gait and delivering more targeted treatment.

  13. Effect of arm swing strategy on local dynamic stability of human gait.

    PubMed

    Punt, Michiel; Bruijn, Sjoerd M; Wittink, Harriet; van Dieën, Jaap H

    2015-02-01

    Falling causes long term disability and can even lead to death. Most falls occur during gait. Therefore improving gait stability might be beneficial for people at risk of falling. Recently arm swing has been shown to influence gait stability. However at present it remains unknown which mode of arm swing creates the most stable gait. To examine how different modes of arm swing affect gait stability. Ten healthy young male subjects volunteered for this study. All subjects walked with four different arm swing instructions at seven different gait speeds. The Xsens motion capture suit was used to capture gait kinematics. Basic gait parameters, variability and stability measures were calculated. We found an increased stability in the medio-lateral direction with excessive arm swing in comparison to normal arm swing at all gait speeds. Moreover, excessive arm swing increased stability in the anterior-posterior and vertical direction at low gait speeds. Ipsilateral and inphase arm swing did not differ compared to a normal arm swing. Excessive arm swing is a promising gait manipulation to improve local dynamic stability. For excessive arm swing in the ML direction there appears to be converging evidence. The effect of excessive arm swing on more clinically relevant groups like the more fall prone elderly or stroke survivors is worth further investigating. Excessive arm swing significantly increases local dynamic stability of human gait. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Gait asymmetry of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees.

    PubMed

    Kaufman, Kenton R; Frittoli, Serena; Frigo, Carlo A

    2012-06-01

    Amputees walk with an asymmetrical gait, which may lead to future musculoskeletal degenerative changes. The purpose of this study was to compare the gait asymmetry of active transfemoral amputees while using a passive mechanical knee joint or a microprocessor-controlled knee joint. Objective 3D gait measurements were obtained in 15 subjects (12 men and 3 women; age 42, range 26-57). Research participants were longtime users of a mechanical prosthesis (mean 20 years, range 3-36 years). Joint symmetry was calculated using a novel method that includes the entire waveform throughout the gait cycle. There was no significant difference in hip, knee and ankle kinematics symmetry when using the different knee prostheses. In contrast, the results demonstrated a significant improvement in lower extremity joint kinetics symmetry when using the microprocessor-controlled knee. Use of the microprocessor-controlled knee joint resulted in improved gait symmetry. These improvements may lead to a reduction in the degenerative musculoskeletal changes often experienced by amputees. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Macrostructural and Microstructural Brain Lesions Relate to Gait Pathology in Children With Cerebral Palsy.

    PubMed

    Meyns, Pieter; Van Gestel, Leen; Leunissen, Inge; De Cock, Paul; Sunaert, Stefan; Feys, Hilde; Duysens, Jacques; Desloovere, Kaat; Ortibus, Els

    2016-10-01

    Background Even though lower-limb motor disorders are core features of spastic cerebral palsy (sCP), the relationship with brain lesions remains unclear. Unraveling the relation between gait pathology, lower-limb function, and brain lesions in sCP is complex for several reasons; wide heterogeneity in brain lesions, ongoing brain maturation, and gait depends on a number of primary motor functions/deficits (eg, muscle strength, spasticity). Objective To use a comprehensive approach combining conventional MRI and diffusion tensor imaging (DTI) in children with sCP above 3 years old to relate quantitative parameters of brain lesions in multiple brain areas to gait performance. Methods A total of 50 children with sCP (25 bilateral, 25 unilateral involvement) were enrolled. The investigated neuroradiological parameters included the following: (1) volumetric measures of the corpus callosum (CC) and lateral ventricles (LVs), and (2) DTI parameters of the corticospinal tract (CST). Gait pathology and primary motor deficits, including muscle strength and spasticity, were evaluated by 3D gait analysis and clinical examination. Results In bilateral sCP (n = 25), volume of the LV and the subparts of the CC connecting frontal, (pre)motor, and sensory areas were most related to lower-limb functioning and gait pathology. DTI measures of the CST revealed additional relations with the primary motor deficits (n = 13). In contrast, in unilateral sCP, volumetric (n = 25) and diffusion measures (n = 14) were only correlated to lower-limb strength. Conclusions These results indicate that the combined influence of multiple brain lesions and their impact on the primary motor deficits might explain a large part of the gait pathology in sCP. © The Author(s) 2016.

  16. Effect of 6-month community-based exercise interventions on gait and functional fitness of an older population: a quasi-experimental study.

    PubMed

    Ramalho, Fátima; Santos-Rocha, Rita; Branco, Marco; Moniz-Pereira, Vera; André, Helô-Isa; Veloso, António P; Carnide, Filomena

    2018-01-01

    Gait ability in older adults has been associated with independent living, increased survival rates, fall prevention, and quality of life. There are inconsistent findings regarding the effects of exercise interventions in the maintenance of gait parameters. The aim of the study was to analyze the effects of a community-based periodized exercise intervention on the improvement of gait parameters and functional fitness in an older adult group compared with a non-periodized program. A quasi-experimental study with follow-up was performed in a periodized exercise group (N=15) and in a non-periodized exercise group (N=13). The primary outcomes were plantar pressure gait parameters, and the secondary outcomes were physical activity, aerobic endurance, lower limb strength, agility, and balance. These variables were recorded at baseline and after 6 months of intervention. Both programs were tailored to older adults' functional fitness level and proved to be effective in reducing the age-related decline regarding functional fitness and gait parameters. Gait parameters were sensitive to both the exercise interventions. These exercise protocols can be used by exercise professionals in prescribing community exercise programs, as well as by health professionals in promoting active aging.

  17. Gait alterations to effectively reduce hip contact forces.

    PubMed

    Wesseling, Mariska; de Groote, Friedl; Meyer, Christophe; Corten, Kristoff; Simon, Jean-Pierre; Desloovere, Kaat; Jonkers, Ilse

    2015-07-01

    Patients with hip pathology present alterations in gait which have an effect on joint moments and loading. In knee osteoarthritic patients, the relation between medial knee contact forces and the knee adduction moment are currently being exploited to define gait retraining strategies to effectively reduce pain and disease progression. However, the relation between hip contact forces and joint moments has not been clearly established. Therefore, this study aims to investigate the effect of changes in hip and pelvis kinematics during gait on internal hip moments and contact forces which is calculated using muscle driven simulations. The results showed that frontal plane kinetics have the largest effect on hip contact forces. Given the high correlation between the change in hip adduction moment and contact force at initial stance (R(2)  = 0.87), this parameter can be used to alter kinematics and predict changes in contact force. At terminal stance the hip adduction and flexion moment can be used to predict changes in contact force (R(2)  = 0.76). Therefore, gait training that focuses on decreasing hip adduction moments, a wide base gait pattern, has the largest potential to reduce hip contact forces. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  18. The gait standard deviation, a single measure of kinematic variability.

    PubMed

    Sangeux, Morgan; Passmore, Elyse; Graham, H Kerr; Tirosh, Oren

    2016-05-01

    Measurement of gait kinematic variability provides relevant clinical information in certain conditions affecting the neuromotor control of movement. In this article, we present a measure of overall gait kinematic variability, GaitSD, based on combination of waveforms' standard deviation. The waveform standard deviation is the common numerator in established indices of variability such as Kadaba's coefficient of multiple correlation or Winter's waveform coefficient of variation. Gait data were collected on typically developing children aged 6-17 years. Large number of strides was captured for each child, average 45 (SD: 11) for kinematics and 19 (SD: 5) for kinetics. We used a bootstrap procedure to determine the precision of GaitSD as a function of the number of strides processed. We compared the within-subject, stride-to-stride, variability with the, between-subject, variability of the normative pattern. Finally, we investigated the correlation between age and gait kinematic, kinetic and spatio-temporal variability. In typically developing children, the relative precision of GaitSD was 10% as soon as 6 strides were captured. As a comparison, spatio-temporal parameters required 30 strides to reach the same relative precision. The ratio stride-to-stride divided by normative pattern variability was smaller in kinematic variables (the smallest for pelvic tilt, 28%) than in kinetic and spatio-temporal variables (the largest for normalised stride length, 95%). GaitSD had a strong, negative correlation with age. We show that gait consistency may stabilise only at, or after, skeletal maturity. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. A multi-channel biomimetic neuroprosthesis to support treadmill gait training in stroke patients.

    PubMed

    Chia, Noelia; Ambrosini, Emilia; Baccinelli, Walter; Nardone, Antonio; Monticone, Marco; Ferrigno, Giancarlo; Pedrocchi, Alessandra; Ferrante, Simona

    2015-01-01

    This study presents an innovative multi-channel neuroprosthesis that induces a biomimetic activation of the main lower-limb muscles during treadmill gait training to be used in the rehabilitation of stroke patients. The electrostimulation strategy replicates the physiological muscle synergies used by healthy subjects to walk on a treadmill at their self-selected speed. This strategy is mapped to the current gait sub-phases, which are identified in real time by a custom algorithm. This algorithm divides the gait cycle into six sub-phases, based on two inertial sensors placed laterally on the shanks. Therefore, the pre-defined stimulation profiles are expanded or stretched based on the actual gait pattern of each single subject. A preliminary experimental protocol, involving 10 healthy volunteers, was carried out to extract the muscle synergies and validate the gait-detection algorithm, which were afterwards used in the development of the neuroprosthesis. The feasibility of the neuroprosthesis was tested on one healthy subject who simulated different gait patterns, and a chronic stroke patient. The results showed the correct functioning of the system. A pilot study of the neurorehabilitation treatment for stroke patients is currently being carried out.

  20. Backward compared to forward over ground gait retraining have additional benefits for gait in individuals with mild to moderate Parkinson's disease: A randomized controlled trial.

    PubMed

    Grobbelaar, Roné; Venter, Ranel; Welman, Karen Estelle

    2017-10-01

    Over ground gait retraining in the reverse direction has shown to be beneficial for neurological rehabilitation, but has not yet been investigated in Parkinson's disease (PD). Backwards walking (BW) might be a useful training alternative to improve PD gait and possibly reduce fall risk during complex multi-directional daily activities. The primary aim was to compare the effect of an eight-week forward (FWG) and backwards (BWG) gait retraining program on gait parameters in PD individuals. Twenty-nine participants (aged 71.0±8.8years; UPDRS-III 38.1±12.3; H&Y 2.7±0.5) were randomly assigned to either the control (FWG; n=14) or experimental group (BWG; n=15). Baseline measures included disease severity (UPDRS III), global cognition (MoCA) and depression (PHQ-9). Outcome measures were selected gait variables on the 10m-instrumented-walk-test (i10mWT) assessed before and after the interventions. Both groups improved usual gait speed (FWG: p=0.03, d=0.35; BWG: p<0.01, d=0.35) and height-normalized gait speed (FWG: p=0.04, d=0.35; BWG: p<0.01, d=0.57). Additionally, the BWG demonstrated improved cadence (p<0.01, d=0.67) and stride length (SL; p=0.02, d=0.39). Both interventions were effective to improved gait speed sufficiently to independently navigate in the community. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. An electromechanical gait trainer for restoration of gait in hemiparetic stroke patients: preliminary results.

    PubMed

    Hesse, S; Werner, C; Uhlenbrock, D; von Frankenberg, S; Bardeleben, A; Brandl-Hesse, B

    2001-01-01

    Modern concepts of gait rehabilitation after stroke favor a task-specific repetitive approach. In practice, the required physical effort of the therapists limits the realization of this approach. Therefore, a mechanized gait trainer enabling nonambulatory patients to have the repetitive practice of a gait-like movement without overstraining therapists was constructed. This preliminary study investigated whether an additional 4-week daily therapy on the gait trainer could improve gait ability in 14 chronic wheelchair-bound hemiparetic subjects. The 4 weeks of physiotherapy and gait-trainer therapy resulted in a relevant improvement of gait ability in all subjects. Velocity, cadence, and stride length improved significantly (p < 0.01). The kinesiologic electromyogram of selected lower-limb muscles revealed a more physiologic pattern. The confounding influence of spontaneous recovery, the lack of a control group, and the double amount of therapy limit the clinical relevance of this study. Nevertheless, the gait trainer seems feasible as an adjunctive tool in gait rehabilitation after stroke; further studies are needed.

  2. The Combined Effects of Body Weight Support and Gait Speed on Gait Related Muscle Activity: A Comparison between Walking in the Lokomat Exoskeleton and Regular Treadmill Walking

    PubMed Central

    Van Kammen, Klaske; Boonstra, Annemarijke; Reinders-Messelink, Heleen; den Otter, Rob

    2014-01-01

    Background For the development of specialized training protocols for robot assisted gait training, it is important to understand how the use of exoskeletons alters locomotor task demands, and how the nature and magnitude of these changes depend on training parameters. Therefore, the present study assessed the combined effects of gait speed and body weight support (BWS) on muscle activity, and compared these between treadmill walking and walking in the Lokomat exoskeleton. Methods Ten healthy participants walked on a treadmill and in the Lokomat, with varying levels of BWS (0% and 50% of the participants’ body weight) and gait speed (0.8, 1.8, and 2.8 km/h), while temporal step characteristics and muscle activity from Erector Spinae, Gluteus Medius, Vastus Lateralis, Biceps Femoris, Gastrocnemius Medialis, and Tibialis Anterior muscles were recorded. Results The temporal structure of the stepping pattern was altered when participants walked in the Lokomat or when BWS was provided (i.e. the relative duration of the double support phase was reduced, and the single support phase prolonged), but these differences normalized as gait speed increased. Alternations in muscle activity were characterized by complex interactions between walking conditions and training parameters: Differences between treadmill walking and walking in the exoskeleton were most prominent at low gait speeds, and speed effects were attenuated when BWS was provided. Conclusion Walking in the Lokomat exoskeleton without movement guidance alters the temporal step regulation and the neuromuscular control of walking, although the nature and magnitude of these effects depend on complex interactions with gait speed and BWS. If normative neuromuscular control of gait is targeted during training, it is recommended that very low speeds and high levels of BWS should be avoided when possible. PMID:25226302

  3. When human walking becomes random walking: fractal analysis and modeling of gait rhythm fluctuations

    NASA Astrophysics Data System (ADS)

    Hausdorff, Jeffrey M.; Ashkenazy, Yosef; Peng, Chang-K.; Ivanov, Plamen Ch.; Stanley, H. Eugene; Goldberger, Ary L.

    2001-12-01

    We present a random walk, fractal analysis of the stride-to-stride fluctuations in the human gait rhythm. The gait of healthy young adults is scale-free with long-range correlations extending over hundreds of strides. This fractal scaling changes characteristically with maturation in children and older adults and becomes almost completely uncorrelated with certain neurologic diseases. Stochastic modeling of the gait rhythm dynamics, based on transitions between different “neural centers”, reproduces distinctive statistical properties of the gait pattern. By tuning one model parameter, the hopping (transition) range, the model can describe alterations in gait dynamics from childhood to adulthood - including a decrease in the correlation and volatility exponents with maturation.

  4. Interpreting sources of variation in clinical gait analysis: A case study.

    PubMed

    King, Stephanie L; Barton, Gabor J; Ranganath, Lakshminarayan R

    2017-02-01

    To illustrate and discuss sources of gait deviations (experimental, genuine and intentional) during a gait analysis and how these deviations inform clinical decision making. A case study of a 24-year old male diagnosed with Alkaptonuria undergoing a routine gait analysis. A 3D motion capture with the Helen-Hayes marker set was used to quantify lower-limb joint kinematics during barefoot walking along a 10m walkway at a self-selected pace. Additional 2D video data were recorded in the sagittal and frontal plane. The patient reported no aches or pains in any joint and described his lifestyle as active. Temporal-spatial parameters were within normal ranges for his age and sex. Three sources of gait deviations were identified; the posteriorly rotated pelvis was due to an experimental error and marker misplacement, the increased rotation of the pelvis in the horizontal plane was genuine and observed in both 3D gait curves and in 2D video analysis, finally the inconsistency in knee flexion/extension combined with a seemingly innocuous interest in the consequences of abnormal gait suggested an intentional gait deviation. Gait analysis is an important analytical tool in the management of a variety of conditions that negatively impact on movement. Experienced gait analysts have the ability to recognise genuine gait adaptations that forms part of the decision-making process for that patient. However, their role also necessitates the ability to identify and correct for experimental errors and critically evaluate when a deviation may not be genuine. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Correlation between the knee adduction torque and medial contact force for a variety of gait patterns.

    PubMed

    Zhao, Dong; Banks, Scott A; Mitchell, Kim H; D'Lima, Darryl D; Colwell, Clifford W; Fregly, Benjamin J

    2007-06-01

    The external knee adduction torque has been proposed as a surrogate measure for medial compartment load during gait. However, a direct link between these two quantities has not been demonstrated using in vivo measurement of medial compartment load. This study uses in vivo data collected from a single subject with an instrumented knee implant to evaluate this link. The subject performed five different overground gait motions (normal, fast, slow, wide, and toe-out) with simultaneous collection of instrumented implant, video motion, and ground reaction data. For each trial, the knee adduction torque was measured externally while the total axial force applied to the tibial insert was measured internally. Based on data collected from the same subject performing treadmill gait under fluoroscopic motion analysis, a regression equation was developed to calculate medial contact force from the implant load cell measurements. Correlation analyses were performed for the stance phase and entire gait cycle to quantify the relationship between the knee adduction torque and both the medial contact force and the medial to total contact force ratio. When the entire gait cycle was analyzed, R(2) for medial contact force was 0.77 when all gait trials were analyzed together and between 0.69 and 0.93 when each gait trial was analyzed separately (p < 0.001 in all cases). For medial to total force ratio, R(2) was 0.69 for all trials together and between 0.54 and 0.90 for each trial separately (p < 0.001 in all cases). When only the stance phase was analyzed, R(2) values were slightly lower. These results support the hypothesis that the knee adduction torque is highly correlated with medial compartment contact force and medial to total force ratio during gait. (c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Validation of enhanced kinect sensor based motion capturing for gait assessment

    PubMed Central

    Müller, Björn; Ilg, Winfried; Giese, Martin A.

    2017-01-01

    Optical motion capturing systems are expensive and require substantial dedicated space to be set up. On the other hand, they provide unsurpassed accuracy and reliability. In many situations however flexibility is required and the motion capturing system can only temporarily be placed. The Microsoft Kinect v2 sensor is comparatively cheap and with respect to gait analysis promising results have been published. We here present a motion capturing system that is easy to set up, flexible with respect to the sensor locations and delivers high accuracy in gait parameters comparable to a gold standard motion capturing system (VICON). Further, we demonstrate that sensor setups which track the person only from one-side are less accurate and should be replaced by two-sided setups. With respect to commonly analyzed gait parameters, especially step width, our system shows higher agreement with the VICON system than previous reports. PMID:28410413

  7. A Combined Cognitive Stimulation and Physical Exercise Programme (MINDVital) in Early Dementia: Differential Effects on Single- and Dual-Task Gait Performance.

    PubMed

    Tay, Laura; Lim, Wee Shiong; Chan, Mark; Ali, Noorhazlina; Chong, Mei Sian

    2016-01-01

    Gait disorders are common in early dementia, with particularly pronounced dual-task deficits, contributing to the increased fall risk and mobility decline associated with cognitive impairment. This study examines the effects of a combined cognitive stimulation and physical exercise programme (MINDVital) on gait performance under single- and dual-task conditions in older adults with mild dementia. Thirty-nine patients with early dementia participated in a multi-disciplinary rehabilitation programme comprising both physical exercise and cognitive stimulation. The programme was conducted in 8-week cycles with participants attending once weekly, and all participants completed 2 successive cycles. Cognitive, functional performance and behavioural symptoms were assessed at baseline and at the end of each 8-week cycle. Gait speed was examined under both single- (Timed Up and Go and 6-metre walk tests) and dual-task (animal category and serial counting) conditions. A random effects model was performed for the independent effect of MINDVital on the primary outcome variable of gait speed under dual-task conditions. The mean age of patients enroled in the rehabilitation programme was 79 ± 6.2 years; 25 (64.1%) had a diagnosis of Alzheimer's dementia, and 26 (66.7%) were receiving a cognitive enhancer therapy. There was a significant improvement in cognitive performance [random effects coefficient (standard error) = 0.90 (0.31), p = 0.003] and gait speed under both dual-task situations [animal category: random effects coefficient = 0.04 (0.02), p = 0.039; serial counting: random effects coefficient = 0.05 (0.02), p = 0.013], with reduced dual-task cost for gait speed [serial counting: random effects coefficient = -4.05 (2.35), p = 0.086] following successive MINDVital cycles. No significant improvement in single-task gait speed was observed. Improved cognitive performance over time was a significant determinant of changes in dual-task gait speed [random effects coefficients

  8. A study of the passive gait of a compass-like biped robot: Symmetry and chaos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goswami, A.; Espiau, B.; Thuilot, B.

    1998-12-01

    The focus of this work is a systematic study of the passive gait of a compass-like planar, biped robot on inclined slopes. The robot is kinematically equivalent to a double pendulum, possessing two kneeless legs with point masses and a third point mass at the hip joint. Three parameters, namely, the ground-slope angle and the normalized mass and length of the robot describe its gait. The authors show that in response to a continuous change in any one of its parameters, the symmetric and steady stable gait of the unpowered robot gradually evolves through a regime of bifurcations characterized bymore » progressively complicated asymmetric gaits, eventually arriving at an apparently chaotic gait where not two steps are identical. The robot can maintain this gait indefinitely. A necessary (but not sufficient) condition for the stability of such gaits is the contraction of the phase-fluid volume. For this frictionless robot, the volume contraction, which the authors compute, is caused by the dissipative effects of the ground-impact model. In the chaotic regime, the fractal dimension of the robot`s strange attractor (2.07) compared to its state-space dimension (4) also reveals strong contraction. The authors present a novel graphical technique based on the first return map that compactly captures the entire evolution of the gait, from symmetry to chaos. Additional passive dissipative elements in the robot joint results in a significant improvement in the stability and the versatility of the gait, and provide a rich repertoire for simple controls laws.« less

  9. Preliminary Assessment of a Compliant Gait Exoskeleton.

    PubMed

    Cestari, Manuel; Sanz-Merodio, Daniel; Garcia, Elena

    2017-06-01

    Current commercial wearable gait exoskeletons contain joints with stiff actuators that cannot adapt to unpredictable environments. These actuators consume a significant amount of energy, and their stiffness may not be appropriate for safe human-machine interactions. Adjustable compliant actuators are being designed and implemented because of their ability to minimize large forces due to shocks, to safely interact with the user, and to store and release energy in passive elastic elements. Introduction of such compliant actuation in gait exoskeletons, however, has been limited by the larger power-to-weight and volume ratio requirement. This article presents a preliminary assessment of the first compliant exoskeleton for children. Compliant actuation systems developed by our research group were integrated into the ATLAS exoskeleton prototype. The resulting device is a compliant exoskeleton, the ATLAS-C prototype. The exoskeleton is coupled with a special standing frame to provide balance while allowing a semi-natural gait. Experiments show that when comparing the behavior of the joints under different stiffness conditions, the inherent compliance of the implemented actuators showed natural adaptability during the gait cycle and in regions of shock absorption. Torque tracking of the joint is achieved, identifying the areas of loading response. The implementation of a state machine in the control of knee motion allowed reutilization of the stored energy during deflection at the end of the support phase to partially propel the leg and achieve a more natural and free swing.

  10. Emotional state affects gait initiation in individuals with Parkinson’s disease

    PubMed Central

    Hass, Chris J.; Bowers, Dawn; Janelle, Christopher M.

    2013-01-01

    The purpose of the present study was to determine the impact of manipulating emotional state on gait initiation in persons with Parkinson’s disease (PD) and healthy older adults. Following the presentation of pictures that are known to elicit specific emotional responses, participants initiated gait and continued to walk for several steps at their normal pace. Reaction time, the displacement and velocity of the center of pressure (COP) trajectory during the preparatory postural adjustments, and length and velocity of the first two steps were measured. Analysis of the gait initiation measures revealed that exposure to (1) threatening pictures, relative to all other pictures, speeded the initiation of gait for PD patients and healthy older adults; (2) approach-oriented emotional pictures (erotic and happy people), relative to withdrawal-oriented pictures, facilitated the anticipatory postural adjustments of gait initiation for PD patients and healthy older adults, as evidenced by greater displacement and velocity of the COP movement; and (3) emotional pictures modulated gait initiation parameters in PD patients to the same degree as in healthy older adults. Collectively, these findings hold significant implications for understanding the circuitry underlying the manner by which emotions modulate movement and for the development of emotion-based interventions designed to maximize improvements in gait initiation for individuals with PD. PMID:22194236

  11. Measuring Gait Quality in Parkinson’s Disease through Real-Time Gait Phase Recognition

    PubMed Central

    Mileti, Ilaria; Germanotta, Marco; Di Sipio, Enrica; Imbimbo, Isabella; Pacilli, Alessandra; Erra, Carmen; Petracca, Martina; Del Prete, Zaccaria; Bentivoglio, Anna Rita; Padua, Luca

    2018-01-01

    Monitoring gait quality in daily activities through wearable sensors has the potential to improve medical assessment in Parkinson’s Disease (PD). In this study, four gait partitioning methods, two based on thresholds and two based on a machine learning approach, considering the four-phase model, were compared. The methods were tested on 26 PD patients, both in OFF and ON levodopa conditions, and 11 healthy subjects, during walking tasks. All subjects were equipped with inertial sensors placed on feet. Force resistive sensors were used to assess reference time sequence of gait phases. Goodness Index (G) was evaluated to assess accuracy in gait phases estimation. A novel synthetic index called Gait Phase Quality Index (GPQI) was proposed for gait quality assessment. Results revealed optimum performance (G < 0.25) for three tested methods and good performance (0.25 < G < 0.70) for one threshold method. The GPQI resulted significantly higher in PD patients than in healthy subjects, showing a moderate correlation with clinical scales score. Furthermore, in patients with severe gait impairment, GPQI was found higher in OFF than in ON state. Our results unveil the possibility of monitoring gait quality in PD through real-time gait partitioning based on wearable sensors. PMID:29558410

  12. Gait and Balance in Essential Tremor: Variable Effects of Bilateral Thalamic Stimulation

    PubMed Central

    Earhart, Gammon M.; Clark, B. Ruth; Tabbal, Samer D.; Perlmutter, Joel S.

    2010-01-01

    Essential tremor (ET) is a multi-faceted condition best known for postural and action tremor but also may include disordered gait and postural instability. Deep brain stimulation (DBS) of the ventral intermediate nucleus (VIM) of the thalamus provides substantial tremor reduction yet some patients with bilateral VIM DBS have gait and balance impairment. This study examines gait and balance performance in 13 participants with ET who have bilateral VIM DBS compared to a matched control group. Participants with ET were tested with their stimulators off (DBS OFF) and on (DBS ON). For both standard and tandem walking, participants with ET walked significantly more slowly than controls, with significantly lower cadence, spending a lower percentage of the gait cycle in single limb support and a higher percentage in double support compared to controls. Participants with ET also had significantly lower tandem and one leg stance times, Berg balance scores, balance confidence, and required significantly greater time to perform the Timed Up-and-Go relative to controls. There were no significant differences in any gait or balance measures in the DBS OFF versus DBS ON conditions, but the effects of DBS on gait and balance were highly variable among individuals. Future studies are needed to determine why some individuals experience gait and balance difficulties after bilateral thalamic DBS and others do not. A better understanding of the mechanisms underlying gait and balance impairments in those with bilateral DBS is critical in order to reduce falls and fractures in this group. PMID:19006189

  13. Gait Analysis Using Wearable Sensors

    PubMed Central

    Tao, Weijun; Liu, Tao; Zheng, Rencheng; Feng, Hutian

    2012-01-01

    Gait analysis using wearable sensors is an inexpensive, convenient, and efficient manner of providing useful information for multiple health-related applications. As a clinical tool applied in the rehabilitation and diagnosis of medical conditions and sport activities, gait analysis using wearable sensors shows great prospects. The current paper reviews available wearable sensors and ambulatory gait analysis methods based on the various wearable sensors. After an introduction of the gait phases, the principles and features of wearable sensors used in gait analysis are provided. The gait analysis methods based on wearable sensors is divided into gait kinematics, gait kinetics, and electromyography. Studies on the current methods are reviewed, and applications in sports, rehabilitation, and clinical diagnosis are summarized separately. With the development of sensor technology and the analysis method, gait analysis using wearable sensors is expected to play an increasingly important role in clinical applications. PMID:22438763

  14. Gait recognition based on Gabor wavelets and modified gait energy image for human identification

    NASA Astrophysics Data System (ADS)

    Huang, Deng-Yuan; Lin, Ta-Wei; Hu, Wu-Chih; Cheng, Chih-Hsiang

    2013-10-01

    This paper proposes a method for recognizing human identity using gait features based on Gabor wavelets and modified gait energy images (GEIs). Identity recognition by gait generally involves gait representation, extraction, and classification. In this work, a modified GEI convolved with an ensemble of Gabor wavelets is proposed as a gait feature. Principal component analysis is then used to project the Gabor-wavelet-based gait features into a lower-dimension feature space for subsequent classification. Finally, support vector machine classifiers based on a radial basis function kernel are trained and utilized to recognize human identity. The major contributions of this paper are as follows: (1) the consideration of the shadow effect to yield a more complete segmentation of gait silhouettes; (2) the utilization of motion estimation to track people when walkers overlap; and (3) the derivation of modified GEIs to extract more useful gait information. Extensive performance evaluation shows a great improvement of recognition accuracy due to the use of shadow removal, motion estimation, and gait representation using the modified GEIs and Gabor wavelets.

  15. Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments.

    PubMed

    Geerse, Daphne J; Coolen, Bert H; Roerdink, Melvyn

    2015-01-01

    Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point's time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point's time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters' walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman's bias and limits of agreement. Body point's time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point's time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained

  16. Recognition using gait.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koch, Mark William

    2007-09-01

    Gait or an individual's manner of walking, is one approach for recognizing people at a distance. Studies in psychophysics and medicine indicate that humans can recognize people by their gait and have found twenty-four different components to gait that taken together make it a unique signature. Besides not requiring close sensor contact, gait also does not necessarily require a cooperative subject. Using video data of people walking in different scenarios and environmental conditions we develop and test an algorithm that uses shape and motion to identify people from their gait. The algorithm uses dynamic time warping to match stored templatesmore » against an unknown sequence of silhouettes extracted from a person walking. While results under similar constraints and conditions are very good, the algorithm quickly degrades with varying conditions such as surface and clothing.« less

  17. Variation of Solar, Interplanetary and Geomagnetic Parameters during Solar Cycles 21-24

    NASA Astrophysics Data System (ADS)

    Oh, Suyeon; Kim, Bogyeong

    2013-06-01

    The length of solar cycle 23 has been prolonged up to about 13 years. Many studies have speculated that the solar cycle 23/24 minimum will indicate the onset of a grand minimum of solar activity, such as the Maunder Minimum. We check the trends of solar (sunspot number, solar magnetic fields, total solar irradiance, solar radio flux, and frequency of solar X-ray flare), interplanetary (interplanetary magnetic field, solar wind and galactic cosmic ray intensity), and geomagnetic (Ap index) parameters (SIG parameters) during solar cycles 21-24. Most SIG parameters during the period of the solar cycle 23/24 minimum have remarkably low values. Since the 1970s, the space environment has been monitored by ground observatories and satellites. Such prevalently low values of SIG parameters have never been seen. We suggest that these unprecedented conditions of SIG parameters originate from the weakened solar magnetic fields. Meanwhile, the deep 23/24 solar cycle minimum might be the portent of a grand minimum in which the global mean temperature of the lower atmosphere is as low as in the period of Dalton or Maunder minimum.

  18. Laboratory review: the role of gait analysis in seniors' mobility and fall prevention.

    PubMed

    Bridenbaugh, Stephanie A; Kressig, Reto W

    2011-01-01

    Walking is a complex motor task generally performed automatically by healthy adults. Yet, by the elderly, walking is often no longer performed automatically. Older adults require more attention for motor control while walking than younger adults. Falls, often with serious consequences, can be the result. Gait impairments are one of the biggest risk factors for falls. Several studies have identified changes in certain gait parameters as independent predictors of fall risk. Such gait changes are often too discrete to be detected by clinical observation alone. At the Basel Mobility Center, we employ the GAITRite electronic walkway system for spatial-temporal gait analysis. Although we have a large range of indications for gait analyses and several areas of clinical research, our focus is on the association between gait and cognition. Gait analysis with walking as a single-task condition alone is often insufficient to reveal underlying gait disorders present during normal, everyday activities. We use a dual-task paradigm, walking while simultaneously performing a second cognitive task, to assess the effects of divided attention on motor performance and gait control. Objective quantification of such clinically relevant gait changes is necessary to determine fall risk. Early detection of gait disorders and fall risk permits early intervention and, in the best-case scenario, fall prevention. We and others have shown that rhythmic movement training such as Jaques-Dalcroze eurhythmics, tai chi and social dancing can improve gait regularity and automaticity, thus increasing gait safety and reducing fall risk. Copyright © 2010 S. Karger AG, Basel.

  19. Effects of unilateral robotic limb loading on gait characteristics in subjects with chronic stroke.

    PubMed

    Khanna, Ira; Roy, Anindo; Rodgers, Mary M; Krebs, Hermano I; Macko, Richard M; Forrester, Larry W

    2010-05-21

    Hemiparesis after stroke often leads to impaired ankle motor control that impacts gait function. In recent studies, robotic devices have been developed to address this impairment. While capable of imparting forces to assist during training and gait, these devices add mass to the paretic leg which might encumber patients' gait pattern. The purpose of this study was to assess the effects of the added mass of one of these robots, the MIT's Anklebot, while unpowered, on gait of chronic stroke survivors during overground and treadmill walking. Nine chronic stroke survivors walked overground and on a treadmill with and without the anklebot mounted on the paretic leg. Gait parameters, interlimb symmetry, and joint kinematics were collected for the four conditions. Repeated-measures analysis of variance (ANOVA) tests were conducted to examine for possible differences across four conditions for the paretic and nonparetic leg. The added inertia and friction of the unpowered anklebot had no statistically significant effect on spatio-temporal parameters of gait, including paretic and nonparetic step time and stance percentage, in both overground and treadmill conditions. Noteworthy, interlimb symmetry as characterized by relative stance duration was greater on the treadmill than overground regardless of loading conditions. The presence of the unpowered robot loading reduced the nonparetic knee peak flexion on the treadmill and paretic peak dorsiflexion overground (p < 0.05). Our results suggest that for these subjects the added inertia and friction of this backdriveable robot did not significantly alter their gait pattern.

  20. Can FES-Augmented Active Cycling Training Improve Locomotion in Post-Acute Elderly Stroke Patients?

    PubMed Central

    Peri, Elisabetta; Ambrosini, Emilia; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Nava, Claudia; Longoni, Valentina; Monticone, Marco; Ferrante, Simona

    2016-01-01

    Recent studies advocated the use of active cycling coupled with functional electrical stimulation to induce neuroplasticity and enhance functional improvements in stroke adult patients. The aim of this work was to evaluate whether the benefits induced by such a treatment are superior to standard physiotherapy. A single-blinded randomized controlled trial has been performed on post-acute elderly stroke patients. Patients underwent FES-augmented cycling training combined with voluntary pedaling or standard physiotherapy. The intervention consisted of fifteen 30-minutes sessions carried out within 3 weeks. Patients were evaluated before and after training, through functional scales, gait analysis and a voluntary pedaling test. Results were compared with an age-matched healthy group. Sixteen patients completed the training. After treatment, a general improvement of all clinical scales was obtained for both groups. Only the mechanical efficiency highlighted a group effect in favor of the experimental group. Although a group effect was not found for any other cycling or gait parameters, the experimental group showed a higher percentage of change with respect to the control group (e.g. the gait velocity was improved of 35.4% and 25.4% respectively, and its variation over time was higher than minimal clinical difference for the experimental group only). This trend suggests that differences in terms of motor recovery between the two groups may be achieved increasing the training dose. In conclusion, this study, although preliminary, showed that FES-augmented active cycling training seems to be effective in improving cycling and walking ability in post-acute elderly stroke patients. A higher sample size is required to confirm results. PMID:27990234

  1. Hardware Development and Locomotion Control Strategy for an Over-Ground Gait Trainer: NaTUre-Gaits.

    PubMed

    Luu, Trieu Phat; Low, Kin Huat; Qu, Xingda; Lim, Hup Boon; Hoon, Kay Hiang

    2014-01-01

    Therapist-assisted body weight supported (TABWS) gait rehabilitation was introduced two decades ago. The benefit of TABWS in functional recovery of walking in spinal cord injury and stroke patients has been demonstrated and reported. However, shortage of therapists, labor-intensiveness, and short duration of training are some limitations of this approach. To overcome these deficiencies, robotic-assisted gait rehabilitation systems have been suggested. These systems have gained attentions from researchers and clinical practitioner in recent years. To achieve the same objective, an over-ground gait rehabilitation system, NaTUre-gaits, was developed at the Nanyang Technological University. The design was based on a clinical approach to provide four main features, which are pelvic motion, body weight support, over-ground walking experience, and lower limb assistance. These features can be achieved by three main modules of NaTUre-gaits: 1) pelvic assistance mechanism, mobile platform, and robotic orthosis. Predefined gait patterns are required for a robotic assisted system to follow. In this paper, the gait pattern planning for NaTUre-gaits was accomplished by an individual-specific gait pattern prediction model. The model generates gait patterns that resemble natural gait patterns of the targeted subjects. The features of NaTUre-gaits have been demonstrated by walking trials with several subjects. The trials have been evaluated by therapists and doctors. The results show that 10-m walking trial with a reduction in manpower. The task-specific repetitive training approach and natural walking gait patterns were also successfully achieved.

  2. Energy expenditure during rest and treadmill gait training in quadriplegic subjects.

    PubMed

    de Carvalho, D C L; Cliquet, A

    2005-11-01

    The analysis of oxygen uptake (VO(2)) and energy consumption in quadriplegics after 6 months of treadmill gait with neuromuscular electrical stimulation (NMES). To compare metabolic responses in quadriplegics after 6 months of treadmill training, with NMES (30-50% body weight relief), with quadriplegics who did not perform gait. Ambulatory of University Hospital, Brazil. Quadriplegics were separated into gait and control groups (CGs). On inclusion, all subjects performed VO(2) test. In the gait group (GG) (n=11), the protocol consisted of 8 min of rest, 10 min of treadmill walking using NMES and 10 min of recovery. In the CG (n=10), testing consisted of 8 min rest, 15 min of quadriceps endurance exercise in sitting position with NMES and 10 min recovery. VO(2), carbon dioxide production (VCO(2)) and energy consumption were measured. The GG performed 6 months of treadmill training, using NMES, for 20 min, twice a week. The CG did not practice any activity with NMES, performing conventional physiotherapy only; the CG was stimulated only during the cardiorespiratory test. All parameters increased significantly for the GG: 36% for VO(2) (l/min), 43% for VCO(2) (l/min) and 32.5% for energy consumption (J/kg/s). For the CG, during knee extension exercise, VO(2) increased without changes in the energy consumption (P<0.05); smaller values were obtained for all parameters when compared to those obtained during gait. Quadriplegic gait was efficient towards increasing VO(2) and energy consumption, which can decrease the risk of cardiovascular diseases. Spinal Cord (2005) 43, 658-663. doi:10.1038/sj.sc.3101776; published online 21 June 2005.

  3. Gait pattern in myotonic dystrophy (Steinert disease): a kinematic, kinetic and EMG evaluation using 3D gait analysis.

    PubMed

    Galli, Manuela; Cimolin, Veronica; Crugnola, Veronica; Priano, Lorenzo; Menegoni, Francesco; Trotti, Claudio; Milano, Eva; Mauro, Alessandro

    2012-03-15

    We investigated the gait pattern of 10 patients with myotonic dystrophy (Steinert disease; 4 females, 6 males; age: 41.5+7.6 years), compared to 20 healthy controls, through manual muscle test and gait analysis, in terms of kinematic, kinetic and EMG data. In most of patients (80%) distal muscle groups were weaker than proximal ones. Weakness at lower limbs was in general moderate to severe and MRC values evidenced a significant correlation between tibialis anterior and gastrocnemius medialis (R=0.91). An overall observation of gait pattern in patients when compared to controls showed that most spatio-temporal parameters (velocity, step length and cadence) were significantly different. As concerns kinematics, patients' pelvic tilt was globally in a higher position than control group, with reduced hip extension ability in stance phase and limited range of motion; 60% of the limbs revealed knee hyperextension during midstance and ankle joints showed a quite physiological position at initial contact and higher dorsiflexion during stance phase if compared to healthy individuals. Kinetic plots evidenced higher hip power during loading response and lower ankle power generation in terminal stance. The main EMG abnormalities were seen in tibialis anterior and gastrocnemius medialis muscles. In this study gait analysis gives objective and quantitative information about the gait pattern and the deviations due to the muscular situation of these patients; these results are important from a clinical point of view and suggest that rehabilitation programs for them should take these findings into account. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Gait patterns in Prader-Willi and Down syndrome patients

    PubMed Central

    2010-01-01

    Background Prader-Willi (PWS) and Down Syndrome (DS) are two genetic disorders characterised by some common clinical and functional features. A quantitative description and comparison of their patterns would contribute to a deeper understanding of the determinants of motor disability in these two syndromes. The aim of this study was to measure gait pattern in PWS and DS in order to provide data for developing evidence-based deficit-specific or common rehabilitation strategies. Methods 19 PWS patients (17.7-40 yr) and 21 DS patients (18-39 yr) were evaluated with an optoelectronic system and force platforms for measuring kinematic and kinetic parameters during walking. The results were compared with those obtained in a group of normal-weight controls (Control Group: CG; 33.4 + 9.6 yr). Results and Discussion The results show that PWS and DS are characterised by different gait strategies. Spatio-temporal parameters indicated a cautious, abnormal gait in both groups, but DS walked with a less stable strategy than PWS. As for kinematics, DS showed a significantly reduced hip and knee flexion, especially at initial contact and ankle range of motion than PWS. DS were characterised by lower ranges of motion (p < 0.05) in all joints than CG and PWS. As for ankle kinetics, both PWS and DS showed a significantly lower push-off during terminal stance than CG, with DS yielding the lowest values. Stiffness at hip and ankle level was increased in DS. PWS showed hip stiffness values close to normal. At ankle level, stiffness was significantly decreased in both groups. Conclusions Our data show that DS walk with a less physiological gait pattern than PWS. Based on our results, PWS and DS patients need targeted rehabilitation and exercise prescription. Common to both groups is the aim to improve hypotonia, muscle strength and motor control during gait. In DS, improving pelvis and hip range of motion should represent a major specific goal to optimize gait pattern. PMID:20565926

  5. Gait patterns in Prader-Willi and Down syndrome patients.

    PubMed

    Cimolin, Veronica; Galli, Manuela; Grugni, Graziano; Vismara, Luca; Albertini, Giorgio; Rigoldi, Chiara; Capodaglio, Paolo

    2010-06-21

    Prader-Willi (PWS) and Down Syndrome (DS) are two genetic disorders characterised by some common clinical and functional features. A quantitative description and comparison of their patterns would contribute to a deeper understanding of the determinants of motor disability in these two syndromes. The aim of this study was to measure gait pattern in PWS and DS in order to provide data for developing evidence-based deficit-specific or common rehabilitation strategies. 19 PWS patients (17.7-40 yr) and 21 DS patients (18-39 yr) were evaluated with an optoelectronic system and force platforms for measuring kinematic and kinetic parameters during walking. The results were compared with those obtained in a group of normal-weight controls (Control Group: CG; 33.4 + 9.6 yr). The results show that PWS and DS are characterised by different gait strategies. Spatio-temporal parameters indicated a cautious, abnormal gait in both groups, but DS walked with a less stable strategy than PWS. As for kinematics, DS showed a significantly reduced hip and knee flexion, especially at initial contact and ankle range of motion than PWS. DS were characterised by lower ranges of motion (p < 0.05) in all joints than CG and PWS. As for ankle kinetics, both PWS and DS showed a significantly lower push-off during terminal stance than CG, with DS yielding the lowest values. Stiffness at hip and ankle level was increased in DS. PWS showed hip stiffness values close to normal. At ankle level, stiffness was significantly decreased in both groups. Our data show that DS walk with a less physiological gait pattern than PWS. Based on our results, PWS and DS patients need targeted rehabilitation and exercise prescription. Common to both groups is the aim to improve hypotonia, muscle strength and motor control during gait. In DS, improving pelvis and hip range of motion should represent a major specific goal to optimize gait pattern.

  6. Modelling gait transition in two-legged animals

    NASA Astrophysics Data System (ADS)

    Pinto, Carla M. A.; Santos, Alexandra P.

    2011-12-01

    The study of locomotor patterns has been a major research goal in the last decades. Understanding how intralimb and interlimb coordination works out so well in animals' locomotion is a hard and challenging task. Many models have been proposed to model animal's rhythms. These models have also been applied to the control of rhythmic movements of adaptive legged robots, namely biped, quadruped and other designs. In this paper we study gait transition in a central pattern generator (CPG) model for bipeds, the 4-cells model. This model is proposed by Golubitsky, Stewart, Buono and Collins and is studied further by Pinto and Golubitsky. We briefly resume the work done by Pinto and Golubitsky. We compute numerically gait transition in the 4-cells CPG model for bipeds. We use Morris-Lecar equations and Wilson-Cowan equations as the internal dynamics for each cell. We also consider two types of coupling between the cells: diffusive and synaptic. We obtain secondary gaits by bifurcation of primary gaits, by varying the coupling strengths. Nevertheless, some bifurcating branches could not be obtained, emphasizing the fact that despite analytically those bifurcations exist, finding them is a hard task and requires variation of other parameters of the equations. We note that the type of coupling did not influence the results.

  7. Gait modification strategies for altering medial knee joint load: a systematic review.

    PubMed

    Simic, Milena; Hinman, Rana S; Wrigley, Tim V; Bennell, Kim L; Hunt, Michael A

    2011-03-01

    To evaluate the effect of gait modification strategies on the external knee adduction moment (KAM), a marker of medial knee joint load; determine potentially adverse effects; assess the methodologic quality; and identify areas of future research. Five electronic databases were searched. Studies evaluating the effects of gait modifications on the KAM in either healthy individuals or those with knee osteoarthritis (OA) were included. Methodologic quality was evaluated by 2 reviewers using the Downs and Black checklist. Twenty-four studies met the inclusion criteria, exploring 14 different gait modifications of varying sample sizes, age groups, and OA classifications. Contralateral cane use, increased step width, medial knee thrust, increased hip internal rotation, weight transfer to the medial foot, and increased lateral trunk lean demonstrated KAM reductions. Tai Chi gait, ipsilateral cane use, Nordic walking poles, and increased knee flexion exhibited increases in the KAM, demonstrating a potential detriment to their use. The effects of reduced stride length, as well as increases and reductions in either toe-out or gait speed, were inconsistent across the studies and gait cycle. This review demonstrates that some gait modifications have the ability to alter knee load. Future research is required to determine the magnitude of modification required to maximize beneficial effects, the best method of training, long-term patient adherence, and if these biomechanical changes can translate into clinically relevant changes in symptoms or disease progression risk. Copyright © 2011 by the American College of Rheumatology.

  8. Quadrupedal gaits in hexapod animals - inter-leg coordination in free-walking adult stick insects.

    PubMed

    Grabowska, Martyna; Godlewska, Elzbieta; Schmidt, Joachim; Daun-Gruhn, Silvia

    2012-12-15

    The analysis of inter-leg coordination in insect walking is generally a study of six-legged locomotion. For decades, the stick insect Carausius morosus has been instrumental for unravelling the rules and mechanisms that control leg coordination in hexapeds. We analysed inter-leg coordination in C. morosus that freely walked on straight paths on plane surfaces with different slopes. Consecutive 1.7 s sections were assigned inter-leg coordination patterns (which we call gaits) based on footfall patterns. Regular gaits, i.e. wave, tetrapod or tripod gaits, occurred in different proportions depending on surface slopes. Tetrapod gaits were observed most frequently, wave gaits only occurred on 90 deg inclining slopes and tripod gaits occurred most often on 15 deg declining slopes, i.e. in 40% of the sections. Depending on the slope, 36-66% of the sections were assigned irregular gaits. Irregular gaits were mostly due to multiple stepping by the front legs, which is perhaps probing behaviour, not phase coupled to the middle legs' cycles. In irregular gaits, middle leg and hindleg coordination was regular, related to quadrupedal walk and wave gaits. Apparently, front legs uncouple from and couple to the walking system without compromising middle leg and hindleg coordination. In front leg amputees, the remaining legs were strictly coordinated. In hindleg and middle leg amputees, the front legs continued multiple stepping. The coordination of middle leg amputees was maladapted, with front legs and hindlegs performing multiple steps or ipsilateral legs being in simultaneous swing. Thus, afferent information from middle legs might be necessary for a regular hindleg stepping pattern.

  9. Artificial Walking Technologies to Improve Gait in Cerebral Palsy: Multichannel Neuromuscular Stimulation.

    PubMed

    Rose, Jessica; Cahill-Rowley, Katelyn; Butler, Erin E

    2017-11-01

    Cerebral palsy (CP) is the most common childhood motor disability and often results in debilitating walking abnormalities, such as flexed-knee and stiff-knee gait. Current medical and surgical treatments are only partially effective in improving gait abnormalities and may cause significant muscle weakness. However, emerging artificial walking technologies, such as step-initiated, multichannel neuromuscular electrical stimulation (NMES), can substantially improve gait patterns and promote muscle strength in children with spastic CP. NMES may also be applied to specific lumbar-sacral sensory roots to reduce spasticity. Development of tablet computer-based multichannel NMES can leverage lightweight, wearable wireless stimulators, advanced control design, and surface electrodes to activate lower-limb muscles. Musculoskeletal models have been used to characterize muscle contributions to unimpaired gait and identify high muscle demands, which can help guide multichannel NMES-assisted gait protocols. In addition, patient-specific NMES-assisted gait protocols based on 3D gait analysis can facilitate the appropriate activation of lower-limb muscles to achieve a more functional gait: stance-phase hip and knee extension and swing-phase sequence of hip and knee flexion followed by rapid knee extension. NMES-assisted gait treatment can be conducted as either clinic-based or home-based programs. Rigorous testing of multichannel NMES-assisted gait training protocols will determine optimal treatment dosage for future clinical trials. Evidence-based outcome evaluation using 3D kinematics or temporal-spatial gait parameters will help determine immediate neuroprosthetic effects and longer term neurotherapeutic effects of step-initiated, multichannel NMES-assisted gait in children with spastic CP. Multichannel NMES is a promising assistive technology to help children with spastic CP achieve a more upright, functional gait. © 2017 International Center for Artificial Organs and

  10. Parkinsonian gait improves with bilateral subthalamic nucleus deep brain stimulation during cognitive multi-tasking.

    PubMed

    Chenji, Gaurav; Wright, Melissa L; Chou, Kelvin L; Seidler, Rachael D; Patil, Parag G

    2017-05-01

    Gait impairment in Parkinson's disease reduces mobility and increases fall risk, particularly during cognitive multi-tasking. Studies suggest that bilateral subthalamic deep brain stimulation, a common surgical therapy, degrades motor performance under cognitive dual-task conditions, compared to unilateral stimulation. To measure the impact of bilateral versus unilateral subthalamic deep brain stimulation on walking kinematics with and without cognitive dual-tasking. Gait kinematics of seventeen patients with advanced Parkinson's disease who had undergone bilateral subthalamic deep brain stimulation were examined off medication under three stimulation states (bilateral, unilateral left, unilateral right) with and without a cognitive challenge, using an instrumented walkway system. Consistent with earlier studies, gait performance declined for all six measured parameters under cognitive dual-task conditions, independent of stimulation state. However, bilateral stimulation produced greater improvements in step length and double-limb support time than unilateral stimulation, and achieved similar performance for other gait parameters. Contrary to expectations from earlier studies of dual-task motor performance, bilateral subthalamic deep brain stimulation may assist in maintaining temporal and spatial gait performance under cognitive dual-task conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Identification of mouse gaits using a novel force-sensing exercise wheel.

    PubMed

    Smith, Benjamin J H; Cullingford, Lottie; Usherwood, James R

    2015-09-15

    The gaits that animals use can provide information on neurological and musculoskeletal disorders, as well as the biomechanics of locomotion. Mice are a common research model in many fields; however, there is no consensus in the literature on how (and if) mouse gaits vary with speed. One of the challenges in studying mouse gaits is that mice tend to run intermittently on treadmills or overground; this paper attempts to overcome this issue with a novel exercise wheel that measures vertical ground reaction forces. Unlike previous instrumented wheels, this wheel is able to measure forces continuously and can therefore record data from consecutive strides. By concatenating the maximum limb force at each time point, a force trace can be constructed to quantify and identify gaits. The wheel was three dimensionally printed, allowing the design to be shared with other researchers. The kinematic parameters measured by the wheel were evaluated using high-speed video. Gaits were classified using a metric called "3S" (stride signal symmetry), which quantifies the half wave symmetry of the force trace peaks. Although mice are capable of using both symmetric and asymmetric gaits throughout their speed range, the continuum of gaits can be divided into regions based on the frequency of symmetric and asymmetric gaits; these divisions are further supported by the fact that mice run less frequently at speeds near the boundaries between regions. The boundary speeds correspond to gait transition speeds predicted by the hypothesis that mice move in a dynamically similar fashion to other legged animals. Copyright © 2015 the American Physiological Society.

  12. Identification of mouse gaits using a novel force-sensing exercise wheel

    PubMed Central

    Cullingford, Lottie; Usherwood, James R.

    2015-01-01

    The gaits that animals use can provide information on neurological and musculoskeletal disorders, as well as the biomechanics of locomotion. Mice are a common research model in many fields; however, there is no consensus in the literature on how (and if) mouse gaits vary with speed. One of the challenges in studying mouse gaits is that mice tend to run intermittently on treadmills or overground; this paper attempts to overcome this issue with a novel exercise wheel that measures vertical ground reaction forces. Unlike previous instrumented wheels, this wheel is able to measure forces continuously and can therefore record data from consecutive strides. By concatenating the maximum limb force at each time point, a force trace can be constructed to quantify and identify gaits. The wheel was three dimensionally printed, allowing the design to be shared with other researchers. The kinematic parameters measured by the wheel were evaluated using high-speed video. Gaits were classified using a metric called “3S” (stride signal symmetry), which quantifies the half wave symmetry of the force trace peaks. Although mice are capable of using both symmetric and asymmetric gaits throughout their speed range, the continuum of gaits can be divided into regions based on the frequency of symmetric and asymmetric gaits; these divisions are further supported by the fact that mice run less frequently at speeds near the boundaries between regions. The boundary speeds correspond to gait transition speeds predicted by the hypothesis that mice move in a dynamically similar fashion to other legged animals. PMID:26139220

  13. Effects of Quadriceps Muscle Fatigue on Stiff-Knee Gait in Patients with Hemiparesis

    PubMed Central

    Boudarham, Julien; Roche, Nicolas; Pradon, Didier; Delouf, Eric; Bensmail, Djamel; Zory, Raphael

    2014-01-01

    The relationship between neuromuscular fatigue and locomotion has never been investigated in hemiparetic patients despite the fact that, in the clinical context, patients report to be more spastic or stiffer after walking a long distance or after a rehabilitation session. The aim of this study was to evaluate the effects of quadriceps muscle fatigue on the biomechanical gait parameters of patients with a stiff-knee gait (SKG). Thirteen patients and eleven healthy controls performed one gait analysis before a protocol of isokinetic quadriceps fatigue and two after (immediately after and after 10 minutes of rest). Spatiotemporal parameters, sagittal knee and hip kinematics, rectus femoris (RF) and vastus lateralis (VL) kinematics and electromyographic (EMG) activity were analyzed. The results showed that quadriceps muscle weakness, produced by repetitive concentric contractions of the knee extensors, induced an improvement of spatiotemporal parameters for patients and healthy subjects. For the patient group, the increase in gait velocity and step length was associated with i) an increase of sagittal hip and knee flexion during the swing phase, ii) an increase of the maximal normalized length of the RF and VL and of the maximal VL lengthening velocity during the pre-swing and swing phases, and iii) a decrease in EMG activity of the RF muscle during the initial pre-swing phase and during the latter 2/3 of the initial swing phase. These results suggest that quadriceps fatigue did not alter the gait of patients with hemiparesis walking with a SKG and that neuromuscular fatigue may play the same functional role as an anti-spastic treatment such as botulinum toxin-A injection. Strength training of knee extensors, although commonly performed in rehabilitation, does not seem to be a priority to improve gait of these patients. PMID:24718087

  14. Joint contact forces can be reduced by improving joint moment symmetry in below-knee amputee gait simulations.

    PubMed

    Koelewijn, Anne D; van den Bogert, Antonie J

    2016-09-01

    Despite having a fully functional knee and hip in both legs, asymmetries in joint moments of the knee and hip are often seen in gait of persons with a unilateral transtibial amputation (TTA), possibly resulting in excessive joint loading. We hypothesize that persons with a TTA can walk with more symmetric joint moments at the cost of increased effort or abnormal kinematics. The hypothesis was tested using predictive simulations of gait. Open loop controls of one gait cycle were found by solving an optimization problem that minimizes a combination of walking effort and tracking error in joint angles, ground reaction force and gait cycle duration. A second objective was added to penalize joint moment asymmetry, creating a multi-objective optimization problem. A Pareto front was constructed by changing the weights of the objectives and three solutions were analyzed to study the effect of increasing joint moment symmetry. When the optimization placed more weight on moment symmetry, walking effort increased and kinematics became less normal, confirming the hypothesis. TTA gait improved with a moderate increase in joint moment symmetry. At a small cost of effort and abnormal kinematics, the peak hip extension moment in the intact leg was decreased significantly, and so was the joint contact force in the knee and hip. Additional symmetry required a significant increase in walking effort and the joint contact forces in both hips became significantly higher than in able-bodied gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Hardware Development and Locomotion Control Strategy for an Over-Ground Gait Trainer: NaTUre-Gaits

    PubMed Central

    Low, Kin Huat; Qu, Xingda; Lim, Hup Boon; Hoon, Kay Hiang

    2014-01-01

    Therapist-assisted body weight supported (TABWS) gait rehabilitation was introduced two decades ago. The benefit of TABWS in functional recovery of walking in spinal cord injury and stroke patients has been demonstrated and reported. However, shortage of therapists, labor-intensiveness, and short duration of training are some limitations of this approach. To overcome these deficiencies, robotic-assisted gait rehabilitation systems have been suggested. These systems have gained attentions from researchers and clinical practitioner in recent years. To achieve the same objective, an over-ground gait rehabilitation system, NaTUre-gaits, was developed at the Nanyang Technological University. The design was based on a clinical approach to provide four main features, which are pelvic motion, body weight support, over-ground walking experience, and lower limb assistance. These features can be achieved by three main modules of NaTUre-gaits: 1) pelvic assistance mechanism, mobile platform, and robotic orthosis. Predefined gait patterns are required for a robotic assisted system to follow. In this paper, the gait pattern planning for NaTUre-gaits was accomplished by an individual-specific gait pattern prediction model. The model generates gait patterns that resemble natural gait patterns of the targeted subjects. The features of NaTUre-gaits have been demonstrated by walking trials with several subjects. The trials have been evaluated by therapists and doctors. The results show that 10-m walking trial with a reduction in manpower. The task-specific repetitive training approach and natural walking gait patterns were also successfully achieved. PMID:27170876

  16. Biomechanical effects of body weight support with a novel robotic walker for over-ground gait rehabilitation.

    PubMed

    Mun, Kyung-Ryoul; Lim, Su Bin; Guo, Zhao; Yu, Haoyong

    2017-02-01

    Body weight support (BWS) promotes better functional outcomes for neurologically challenged patients. Despite the established effectiveness of BWS in gait rehabilitation, the findings on biomechanical effects of BWS training still remain contradictory. Therefore, the aim of this study is to comprehensively investigate the effects of BWS. Using a newly developed robotic walker which can facilitate pelvic motions with an active BWS unit, we compared gait parameters of ten healthy subjects during a 10-m walk with incremental levels of body weight unloading, ranging from 0 to 40 % at 10 % intervals. Significant changes in joint angles and gait temporospatial parameters were observed. In addition, the results of an EMG signal study showed that the intensity of muscle activation was significantly reduced with increasing BWS levels. The reduction was found at the ankle, knee, and hip joints in the sagittal plane as well as at the hip joint in the frontal plane. The results of this study provide an important indication of increased lateral body balance and greater stabilization in sagittal and frontal plane during gait. Our findings provide a better understanding of the biomechanical effects of BWS during gait, which will help guide the gait rehabilitation strategies.

  17. Early rehabilitation treatment combined with equinovarus foot deformity surgical correction in stroke patients: safety and changes in gait parameters.

    PubMed

    Giannotti, Erika; Merlo, Andrea; Zerbinati, Paolo; Longhi, Maria; Prati, Paolo; Masiero, Stefano; Mazzoli, Davide

    2016-06-01

    Equinovarus foot deformity (EVFD) compromises several prerequisites of walking and increases the risk of falling. Guidelines on rehabilitation following EVFD surgery are missing in current literature. The aim of this study was to analyze safety and adherence to an early rehabilitation treatment characterized by immediate weight bearing with an ankle-foot orthosis (AFO) in hemiplegic patients after EVFD surgery and to describe gait changes after EVFD surgical correction combined with early rehabilitation treatment. Retrospective observational cohort study. Inpatient rehabilitation clinic. Forty-seven adult patients with hemiplegia consequent to ischemic or haemorrhagic stroke (L/R 20/27, age 56±15 years, time from lesion 6±5 years). A specific rehabilitation protocol with a non-articulated AFO, used to allow for immediate gait training, started one day after EVFD surgery. Gait analysis (GA) data before and one month after surgery were analyzed. The presence of differences in GA space-time parameters, in ankle dorsiflexion (DF) values and peaks at initial contact (DF at IC), during stance (DF at St) and swing (DF at Sw) were assessed by the Wilcoxon Test while the presence of correlations between pre- and post-operative values by Spearman's correlation coefficient. All patients completed the rehabilitation protocol and no clinical complications occurred in the sample. Ankle DF increased one month after surgery at all investigated gait phases (Wilcoxon Test, P<0.0001), becoming neutral at IC. Significant (P<0.05) variations were found for stride length, stride width, anterior step length of the affected side and for the duration of the double support phase of the contralateral side. The postsurgery ankle DF at St was found to be correlated (R=0.81, P<0.0001) with its pre-surgery value, thus being predictable. Weaker significant correlations were found for DF at Sw and DF at IC, where contribution from the dorsiflexor muscles is required in addition to calf muscle

  18. Functional implications of muscle co-contraction during gait in advanced age.

    PubMed

    Lo, Justine; Lo, On-Yee; Olson, Erin A; Habtemariam, Daniel; Iloputaife, Ikechukwu; Gagnon, Margaret M; Manor, Brad; Lipsitz, Lewis A

    2017-03-01

    Older adults often exhibit high levels of lower extremity muscle co-contraction, which may be the cause or effect of age-related impairments in gait and associated falls. Normal gait requires intact executive function and thus can be slowed by challenging executive resources available to the neuromuscular system through the performance of a dual task. We therefore investigated associations between lower limb co-contraction and gait characteristics under normal and dual task conditions in healthy older adults (85.4±5.9years). We hypothesized that greater co-contraction is associated with slower gait speed during dual task conditions that stress executive and attentional abilities. Co-contraction was quantified during different phases of the gait cycle using surface electromyography (EMG) signals obtained from the anterior tibialis and lateral gastrocnemius while walking at preferred speed during normal and dual task conditions. Variables included the time difference to complete the Trail Making Test A and B (ΔTMT) and gait measures during normal or dual task walking. Higher co-contraction levels during the swing phase of both normal and dual task walking were associated with longer ΔTMT (normal: R 2 =0.25, p=0.02; dual task: R 2 =0.27, p=0.01). Co-contraction was associated with gait measures during dual task walking only; greater co-contraction levels during stride and stance were associated with slower gait speed (stride: R 2 =0.38, p=0.04; stance: R 2 =0.38, p=0.04), and greater co-contraction during stride was associated with longer stride time (R 2 =0.16, p=0.03). Our results suggest that relatively high lower limb co-contraction may explain some of the mobility impairments associated with the conduct of executive tasks in older adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Disturbances of automatic gait control mechanisms in higher level gait disorder.

    PubMed

    Danoudis, Mary; Ganesvaran, Ganga; Iansek, Robert

    2016-07-01

    The underlying mechanisms responsible for the gait changes in frontal gait disorder (FGD), a form of higher level gait disorders, are poorly understood. We investigated the relationship between stride length and cadence (SLCrel) in people with FGD (n=15) in comparison to healthy older adults (n=21) to improve our understanding of the changes to gait in FGD. Gait data was captured using an electronic walkway system as participants walked at five self-selected speed conditions: preferred, very slow, slow, fast and very fast. Linear regression was used to determine the strength of the relationship (R(2)), slope and intercept. In the FGD group 9 participants had a strong SLCrel (linear group) (R(2)>0.8) and 6 a weak relationship (R(2)<0.8) (nonlinear group). The linear FGD group did not differ to healthy control for slope (p>0.05) but did have a lower intercept (p<0.001). The linear FGD group modulated gait speed by adjusting stride length and cadence similar to controls whereas the nonlinear FGD participants adjusted stride length but not cadence similar to controls. The non-linear FGD group had greater disturbance to their gait, poorer postural control and greater fear of falling compared to the linear FGD group. Investigation of the SLCrel resulted in new insights into the underlying mechanisms responsible for the gait changes found in FGD. The findings suggest stride length regulation was disrupted in milder FGD but as the disorder worsened, cadence control also became disordered resulting in a break down in the relationship between stride length and cadence. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Accelerometric gait analysis for use in hospital outpatients.

    PubMed

    Auvinet, B; Chaleil, D; Barrey, E

    1999-01-01

    To provide clinicians with a quantitative human gait analysis tool suitable for routine use. We evaluated the reproducibility, sensitivity, and specificity of gait analysis based on measurements of acceleration at a point near the center of gravity of the body. Two accelerometers held over the middle of the low back by a semi-elastic belt were used to record craniocaudal and side-to-side accelerations at a frequency of 50 Hz. Subjects were asked to walk at their normal speed to the end of a straight 40 meter-long hospital corridor and back. A 20-second period of stabilized walking was used to calculate cycle frequency, stride symmetry, and stride regularity. Symmetry and regularity were each derived from an auto-correlation coefficient; to convert their distribution from nonnormal to normal, Fisher's Z transformation was applied to the auto-coefficients for these two variables. Intraobserver reproducibility was evaluated by asking the same observer to test 16 controls on three separate occasions at two-day intervals and interobserver reproducibility by asking four different observers to each test four controls (Latin square). Specificity and sensitivity were determined by testing 139 controls and 63 patients. The 139 controls (70 women and 69 men) were divided into five age groups (third through seventh decades of life). The 63 patients had a noninflammatory musculoskeletal condition predominating on one side. ROC curves were used to determine the best cutoffs for separating normal from abnormal values. Neither intra- nor interobserver variability was significant (P > 0.05). Cycle frequency was significantly higher in female than in male controls (1.05 +/- 0.06 versus 0.98 +/- 0.05 cycles/s; P < 0.001). Neither symmetry nor regularity were influenced by gender in the controls; both variables were also unaffected by age, although nonsignificant decreases were found in the 61 to 70-year age group, which included only nine subjects. In the ROC curve analysis, the area

  1. Effects of yoga on balance and gait properties in women with musculoskeletal problems: a pilot study.

    PubMed

    Ulger, Ozlem; Yağlı, Naciye Vardar

    2011-02-01

    The purpose of the present study is to investigate the effects of yoga on balance and gait properties in women with musculoskeletal problems. Twenty-seven women (30-45 years old) with musculoskeletal problems, such as osteoarthritis and low-back pain, were included in the present study. The patients participated in 8 sessions (twice weekly for 4 weeks) of a yoga program which included asanas, stretching exercises, and breathing techniques. Patients' static balance measurements and gait parameters were determined before and after the study using a stabilometer and a gait trainer, respectively. Post-study values of patients' gait parameters were found to be statistically higher than their pre-study values (p < 0.05) The values of patients' balance addressed anterior and right positions with patients' eyes open and subsequently closed pre-treatment. However, it was notable that balance post-treatment was minimal when subjects eyes were open or closed. Anterior-posterior values and right-left values were almost equal after treatment. The results showed that yoga has a positive effect on balance and gait parameters of women with gait and balance disturbances that are caused by musculoskeletal problems. It is feasible to conclude that asanas and stretching exercises included in the yoga program brought about such a positive effect, and therefore it is possible to use yoga programs to solve problems caused by musculoskeletal disorders. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Why is walker-assisted gait metabolically expensive?

    PubMed

    Priebe, Jonathon R; Kram, Rodger

    2011-06-01

    Walker-assisted gait is reported to be ∼200% more metabolically expensive than normal bipedal walking. However, previous studies compared different walking speeds. Here, we compared the metabolic power consumption and basic stride temporal-spatial parameters for 10 young, healthy adults walking without assistance and using 2-wheeled (2W), 4-wheeled (4W) and 4-footed (4F) walker devices, all at the same speed, 0.30m/s. We also measured the metabolic power demand for walking without any assistive device using a step-to gait at 0.30m/s, walking normally at 1.25m/s, and for repeated lifting of the 4F walker mimicking the lifting pattern used during 4F walker-assisted gait. Similar to previous studies, we found that the cost per distance walked was 217% greater with a 4F walker at 0.30m/s compared to unassisted, bipedal walking at 1.25m/s. Compared at the same speed, 0.30m/s, using a 4F walker was still 82%, 74%, and 55% energetically more expensive than walking unassisted, with a 4W walker and a 2W walker respectively. The sum of the metabolic cost of step-to walking plus the cost of lifting itself was equivalent to the cost of walking with a 4F walker. Thus, we deduce that the high cost of 4F walker assisted gait is due to three factors: the slow walking speed, the step-to gait pattern and the repeated lifting of the walker. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Reliable sagittal plane kinematic gait assessments are feasible using low-cost webcam technology.

    PubMed

    Saner, Robert J; Washabaugh, Edward P; Krishnan, Chandramouli

    2017-07-01

    Three-dimensional (3-D) motion capture systems are commonly used for gait analysis because they provide reliable and accurate measurements. However, the downside of this approach is that it is expensive and requires technical expertise; thus making it less feasible in the clinic. To address this limitation, we recently developed and validated (using a high-precision walking robot) a low-cost, two-dimensional (2-D) real-time motion tracking approach using a simple webcam and LabVIEW Vision Assistant. The purpose of this study was to establish the repeatability and minimal detectable change values of hip and knee sagittal plane gait kinematics recorded using this system. Twenty-one healthy subjects underwent two kinematic assessments while walking on a treadmill at a range of gait velocities. Intraclass correlation coefficients (ICC) and minimal detectable change (MDC) values were calculated for commonly used hip and knee kinematic parameters to demonstrate the reliability of the system. Additionally, Bland-Altman plots were generated to examine the agreement between the measurements recorded on two different days. The system demonstrated good to excellent reliability (ICC>0.75) for all the gait parameters tested on this study. The MDC values were typically low (<5°) for most of the parameters. The Bland-Altman plots indicated that there was no systematic error or bias in kinematic measurements and showed good agreement between measurements obtained on two different days. These results indicate that kinematic gait assessments using webcam technology can be reliably used for clinical and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Basal ganglia and gait control: apomorphine administration and internal pallidum stimulation in Parkinson's disease.

    PubMed

    Grasso, R; Peppe, A; Stratta, F; Angelini, D; Zago, M; Stanzione, P; Lacquaniti, F

    1999-05-01

    Gait coordination was analyzed (four-camera 100 Hz ELITE system) in two groups of idiopathic Parkinson disease (PD) patients. Five patients underwent continuous infusion of apomorphine and were recorded in two different sessions (APO OFF and APO ON) in the same day. Three patients with a previous chronic electrode implantation in both internal globi pallidi (GPi) were recorded in the same experimental session with the electrodes on and off (STIM ON and STIM OFF). The orientation of both the trunk and the lower-limb segments was described with respect to the vertical in the sagittal plane. Lower-limb inter-segmental coordination was evaluated by analyzing the co-variation between thigh, shank, and foot elevation angles by means of orthogonal planar regression. At least 30 gait cycles per experimental condition were processed. We found that the trunk was bent forward in STIM OFF, whereas it was better aligned with the vertical in STIM ON in both PD groups. The legs never fully extended during the gait cycle in STIM OFF, whereas they extended before heel strike in STIM ON. The multisegmental coordination of the lower limb changed almost in parallel with the changes in trunk orientation. In STIM OFF, both the shape and the spatial orientation of the planar gait loops (thigh angle vs. shank angle vs. foot angle) differed from those of physiological locomotion, whereas in STIM ON the gait loop tended to resume features closer to the control. Switching the electrodes on and off in patients with GPi electrodes resulted in quasi-parallel changes of the trunk inclination and of the planar gait loop. The bulk of the data suggest that the basal-ganglia circuitry may be relevant in locomotion by providing an appropriate spatio-temporal framework for the control of posture and movement in a gravity-based body-centered frame of reference. Pallido-thalamic and/or pallido-mesencephalic pathways may influence the timing of the inter-segmental coordination for gait.

  5. Evidence of end-effector based gait machines in gait rehabilitation after CNS lesion.

    PubMed

    Hesse, S; Schattat, N; Mehrholz, J; Werner, C

    2013-01-01

    A task-specific repetitive approach in gait rehabilitation after CNS lesion is well accepted nowadays. To ease the therapists' and patients' physical effort, the past two decades have seen the introduction of gait machines to intensify the amount of gait practice. Two principles have emerged, an exoskeleton- and an endeffector-based approach. Both systems share the harness and the body weight support. With the end-effector-based devices, the patients' feet are positioned on two foot plates, whose movements simulate stance and swing phase. This article provides an overview on the end-effector based machine's effectiveness regarding the restoration of gait. For the electromechanical gait trainer GT I, a meta analysis identified nine controlled trials (RCT) in stroke subjects (n = 568) and were analyzed to detect differences between end-effector-based locomotion + physiotherapy and physiotherapy alone. Patients practising with the machine effected in a superior gait ability (210 out of 319 patients, 65.8% vs. 96 out of 249 patients, 38.6%, respectively, Z = 2.29, p = 0.020), due to a larger training intensity. Only single RCTs have been reported for other devices and etiologies. The introduction of end-effector based gait machines has opened a new succesful chapter in gait rehabilitation after CNS lesion.

  6. Combined robotic-aided gait training and physical therapy improve functional abilities and hip kinematics during gait in children and adolescents with acquired brain injury.

    PubMed

    Beretta, Elena; Romei, Marianna; Molteni, Erika; Avantaggiato, Paolo; Strazzer, Sandra

    2015-01-01

    To evaluate the combined effect of robotic-aided gait training (RAGT) and physical therapy (PT) on functional abilities and gait pattern in children and adolescents exiting acquired brain injury (ABI), through functional clinical scales and 3D-Gait Analysis (GA). A group of 23 patients with ABI underwent 20 sessions of RAGT in addition to traditional manual PT. All the patients were evaluated before and after the training by using the Gross Motor Function Measures (GMFM) and the Functional Assessment Questionnaire. Ambulant children were also evaluated through the 6 Minutes Walk Test (6MinWT) and GA. Finally, results were compared with those obtained from a control group of ABI children who underwent PT only. After the training, the GMFM showed significant improvement in both dimensions 'D' (standing) and 'E' (walking). In ambulant patients the 6MinWT showed significant improvement after training and GA highlighted a significant increase in cadence, velocity and stride length. Moreover, hip kinematics on the sagittal plane revealed a statistically significant increase in range of motion (ROM) during the whole gait cycle, increased hip extension during terminal stance and increased ROM during the swing phase. The data suggest that the combined programme RAGT + PT induces improvements in functional activities and gait pattern in children and adolescents with ABI and demonstrated it to be an elective tool for the maintenance of the patients' full compliance throughout the rehabilitative programme.

  7. Walking while talking: Young adults flexibly allocate resources between speech and gait.

    PubMed

    Raffegeau, Tiphanie E; Haddad, Jeffrey M; Huber, Jessica E; Rietdyk, Shirley

    2018-05-26

    Walking while talking is an ideal multitask behavior to assess how young healthy adults manage concurrent tasks as it is well-practiced, cognitively demanding, and has real consequences for impaired performance in either task. Since the association between cognitive tasks and gait appears stronger when the gait task is more challenging, gait challenge was systematically manipulated in this study. To understand how young adults accomplish the multitask behavior of walking while talking as the gait challenge was systematically manipulated. Sixteen young adults (21 ± 1.6 years, 9 males) performed three gait tasks with and without speech: unobstructed gait (easy), obstacle crossing (moderate), obstacle crossing and tray carrying (difficult). Participants also provided a speech sample while seated for a baseline indicator of speech. The speech task was to speak extemporaneously about a topic (e.g. first car). Gait speed and the duration of silent pauses during speaking were determined. Silent pauses reflect cognitive processes involved in speech production and language planning. When speaking and walking without obstacles, gait speed decreased (relative to walking without speaking) but silent pause duration did not change (relative to seated speech). These changes are consistent with the idea that, in the easy gait task, participants placed greater value on speech pauses than on gait speed, likely due to the negative social consequences of impaired speech. In the moderate and difficult gait tasks both parameters changed: gait speed decreased and silent pauses increased. Walking while talking is a cognitively demanding task for healthy young adults, despite being a well-practiced habitual activity. These findings are consistent with the integrated model of task prioritization from Yogev-Seligmann et al., [1]. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait

    PubMed Central

    2014-01-01

    Background Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting number of steps to be analyzed. Traditional measuring gait systems carry out their measurement at frequencies oscillating between 60 to 100 Hz. It can be argued about the need of higher sampling rates for gait measurements. However small displacements of the knee or hip for example, cannot be seen with low frequencies required a more detailed sampling and higher frequency sampling. Bearing this in mind, in this paper is presented a 250 Hz system based on accelerometers for gait measurement, and the particularities of knee and hip angles during gait are highlighted. Methods The system was designed with a PCI data acquisition card instrumented with an FPGA to achieve a rate sample of 250 Hz. The accelerometers were placed in thighs and legs to calculate the joint angles of hip and knee in the sagittal plane. The angles were estimated using the acceleration polygon method without integrating the acceleration and without filters. Results The gait of thirty healthy people of Mexican phenotype was analyzed over a flat floor free of obstacles. The results showed the gait phases and particularities associated with the walking style and people's laterality; the movement patterns were similar in the thirty persons. Based on the results, the particularities as the maximum amplitude in the angles and the shape in the movement patterns were related to the anthropometry and people phenotype. Conclusions The sampling frequency was essential to record 340 samples in single gait cycle and so registering the gait cycle with its particularities. In this work were recorded an average of 8 to 10 gait cycles, and the results showed variation regarding works carried out

  9. A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait.

    PubMed

    Martínez-Solís, Fermín; Claudio-Sánchez, Abraham; Rodríguez-Lelis, José M; Vergara-Limon, Sergio; Olivares-Peregrino, Víctor; Vargas-Treviño, Marciano

    2014-03-31

    Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting number of steps to be analyzed. Traditional measuring gait systems carry out their measurement at frequencies oscillating between 60 to 100 Hz. It can be argued about the need of higher sampling rates for gait measurements. However small displacements of the knee or hip for example, cannot be seen with low frequencies required a more detailed sampling and higher frequency sampling. Bearing this in mind, in this paper is presented a 250 Hz system based on accelerometers for gait measurement, and the particularities of knee and hip angles during gait are highlighted. The system was designed with a PCI data acquisition card instrumented with an FPGA to achieve a rate sample of 250 Hz. The accelerometers were placed in thighs and legs to calculate the joint angles of hip and knee in the sagittal plane. The angles were estimated using the acceleration polygon method without integrating the acceleration and without filters. The gait of thirty healthy people of Mexican phenotype was analyzed over a flat floor free of obstacles. The results showed the gait phases and particularities associated with the walking style and people's laterality; the movement patterns were similar in the thirty persons. Based on the results, the particularities as the maximum amplitude in the angles and the shape in the movement patterns were related to the anthropometry and people phenotype. The sampling frequency was essential to record 340 samples in single gait cycle and so registering the gait cycle with its particularities. In this work were recorded an average of 8 to 10 gait cycles, and the results showed variation regarding works carried out in biomechanics laboratories; this

  10. The development and validity of the Salford Gait Tool: an observation-based clinical gait assessment tool.

    PubMed

    Toro, Brigitte; Nester, Christopher J; Farren, Pauline C

    2007-03-01

    To develop the construct, content, and criterion validity of the Salford Gait Tool (SF-GT) and to evaluate agreement between gait observations using the SF-GT and kinematic gait data. Tool development and comparative evaluation. University in the United Kingdom. For designing construct and content validity, convenience samples of 10 children with hemiplegic, diplegic, and quadriplegic cerebral palsy (CP) and 152 physical therapy students and 4 physical therapists were recruited. For developing criterion validity, kinematic gait data of 13 gait clusters containing 56 children with hemiplegic, diplegic, and quadriplegic CP and 11 neurologically intact children was used. For clinical evaluation, a convenience sample of 23 pediatric physical therapists participated. We developed a sagittal plane observational gait assessment tool through a series of design, test, and redesign iterations. The tool's grading system was calibrated using kinematic gait data of 13 gait clusters and was evaluated by comparing the agreement of gait observations using the SF-GT with kinematic gait data. Criterion standard kinematic gait data. There was 58% mean agreement based on grading categories and 80% mean agreement based on degree estimations evaluated with the least significant difference method. The new SF-GT has good concurrent criterion validity.

  11. Post-stroke hemiparesis: Does chronicity, etiology, and lesion side are associated with gait pattern?

    PubMed

    Gama, Gabriela Lopes; Larissa, Coutinho de Lucena; Brasileiro, Ana Carolina de Azevedo Lima; Silva, Emília Márcia Gomes de Souza; Galvão, Élida Rayanne Viana Pinheiro; Maciel, Álvaro Cavalcanti; Lindquist, Ana Raquel Rodrigues

    2017-07-01

    Studies that evaluate gait rehabilitation programs for individuals with stroke often consider time since stroke of more than six months. In addition, most of these studies do not use lesion etiology or affected cerebral hemisphere as study factors. However, it is unknown whether these factors are associated with post-stroke motor performance after the spontaneous recovery period. To investigate whether time since stroke onset, etiology, and lesion side is associated with spatiotemporal and angular gait parameters of individuals with chronic stroke. Fifty individuals with chronic hemiparesis (20 women) were evaluated. The sample was stratified according to time since stroke (between 6 and 12 months, between 13 and 36 months, and over 36 months), affected cerebral hemisphere (left or right) and lesion etiology (ischemic and hemorrhagic). The participants were evaluated during overground walking at self-selected gait speed, and spatiotemporal and angular gait parameters were calculated. Results Differences between gait speed, stride length, hip flexion, and knee flexion were observed in subgroups stratified based on lesion etiology. Survivors of a hemorrhagic stroke exhibited more severe gait impairment. Subgroups stratified based on time since stroke only showed intergroup differences for stride length, and subgroups stratified based on affected cerebral hemisphere displayed between-group differences for swing time symmetry ratio. In order to recruit a more homogeneous sample, more accurate results were obtained and an appropriate rehabilitation program was offered, researchers and clinicians should consider that gait pattern might be associated with time since stroke, affected cerebral hemisphere and lesion etiology.

  12. Falls, Cognitive Impairment, and Gait Performance: Results From the GOOD Initiative

    PubMed Central

    Allali, Gilles; Launay, Cyrille P.; Blumen, Helena M.; Callisaya, Michele L.; De Cock, Anne-Marie; Kressig, Reto W.; Srikanth, Velandai; Steinmetz, Jean-Paul; Verghese, Joe; Beauchet, Olivier

    2017-01-01

    Objectives Falls are highly prevalent in individuals with cognitive decline. The complex relationship between falls and cognitive decline (including both subtype and severity of dementia) and the influence of gait disorders have not been studied. This study aimed to examine the association between the subtype (Alzheimer disease [AD] versus non-AD) and the severity (from preclinical to moderate dementia) of cognitive impairment and falls, and to establish an association between falls and gait parameters during the course of dementia. Design Multicenter cross-sectional study. Setting “Gait, cOgnitiOn & Decline” (GOOD) initiative. Participants A total of 2496 older adults (76.6 ± 7.6 years; 55.0% women) were included in this study (1161 cognitively healthy individuals [CHI], 529 patients with mild cognitive impairment [MCI], 456 patients with mild dementia, and 350 with moderate dementia) from 7 countries. Measurements Falls history was collected retrospectively at baseline in each study. Gait speed and stride time variability were recorded at usual walking pace with the GAITRite system. Results The prevalence of individuals who fall was 50% in AD and 64% in non-AD; whereas it was 25% in CHIs. Only mild and moderate non-AD dementia were associated with an increased risk for falls in comparison with CHI. Higher stride time variability was associated with falls in older adults without dementia (CHI and each MCI subgroup) and mild non-AD dementia, whereas lower gait speed was associated with falls in all participant groups, except in mild AD dementia. When gait speed was adjusted for, higher stride time variability was associated with falls only in CHIs (odds ratio 1.14; P = .012), but not in MCI or in patients with dementia. Conclusions These findings suggest that non-AD, but not AD dementia, is associated with increased falls in comparison with CHIs. The association between gait parameters and falls also differs across cognitive status, suggesting different

  13. Gait Biomechanics of Individuals with Transtibial Amputation: Effect of Suspension System

    PubMed Central

    Eshraghi, Arezoo; Abu Osman, Noor Azuan; Karimi, Mohammad; Gholizadeh, Hossein; Soodmand, Ehsan; Abas, Wan Abu Bakar Wan

    2014-01-01

    Prosthetic suspension system is an important component of lower limb prostheses. Suspension efficiency can be best evaluated during one of the vital activities of daily living, i.e. walking. A new magnetic prosthetic suspension system has been developed, but its effects on gait biomechanics have not been studied. This study aimed to explore the effect of suspension type on kinetic and kinematic gait parameters during level walking with the new suspension system as well as two other commonly used systems (the Seal-In and pin/lock). Thirteen persons with transtibial amputation participated in this study. A Vicon motion system (six cameras, two force platforms) was utilized to obtain gait kinetic and kinematic variables, as well as pistoning within the prosthetic socket. The gait deviation index was also calculated based on the kinematic data. The findings indicated significant difference in the pistoning values among the three suspension systems. The Seal-In system resulted in the least pistoning compared with the other two systems. Several kinetic and kinematic variables were also affected by the suspension type. The ground reaction force data showed that lower load was applied to the limb joints with the magnetic suspension system compared with the pin/lock suspension. The gait deviation index showed significant deviation from the normal with all the systems, but the systems did not differ significantly. Main significant effects of the suspension type were seen in the GRF (vertical and fore-aft), knee and ankle angles. The new magnetic suspension system showed comparable effects in the remaining kinetic and kinematic gait parameters to the other studied systems. This study may have implications on the selection of suspension systems for transtibial prostheses. Trial Registration Iranian Registry of Clinical Trials IRCT2013061813706N1. PMID:24865351

  14. Gait characteristics under different walking conditions: Association with the presence of cognitive impairment in community-dwelling older people

    PubMed Central

    Fransen, Erik; Perkisas, Stany; Verhoeven, Veronique; Beauchet, Olivier; Remmen, Roy

    2017-01-01

    Background Gait characteristics measured at usual pace may allow profiling in patients with cognitive problems. The influence of age, gender, leg length, modified speed or dual tasking is unclear. Methods Cross-sectional analysis was performed on a data registry containing demographic, physical and spatial-temporal gait parameters recorded in five walking conditions with a GAITRite® electronic carpet in community-dwelling older persons with memory complaints. Four cognitive stages were studied: cognitively healthy individuals, mild cognitive impaired patients, mild dementia patients and advanced dementia patients. Results The association between spatial-temporal gait characteristics and cognitive stages was the most prominent: in the entire study population using gait speed, steps per meter (translation for mean step length), swing time variability, normalised gait speed (corrected for leg length) and normalised steps per meter at all five walking conditions; in the 50-to-70 years old participants applying step width at fast pace and steps per meter at usual pace; in the 70-to-80 years old persons using gait speed and normalised gait speed at usual pace, fast pace, animal walk and counting walk or steps per meter and normalised steps per meter at all five walking conditions; in over-80 years old participants using gait speed, normalised gait speed, steps per meter and normalised steps per meter at fast pace and animal dual-task walking. Multivariable logistic regression analysis adjusted for gender predicted in two compiled models the presence of dementia or cognitive impairment with acceptable accuracy in persons with memory complaints. Conclusion Gait parameters in multiple walking conditions adjusted for age, gender and leg length showed a significant association with cognitive impairment. This study suggested that multifactorial gait analysis could be more informative than using gait analysis with only one test or one variable. Using this type of gait analysis

  15. Generation of Adaptive Gait Patterns for Quadruped Robot with CPG Network including Motor Dynamic Model

    NASA Astrophysics Data System (ADS)

    Son, Yurak; Kamano, Takuya; Yasuno, Takashi; Suzuki, Takayuki; Harada, Hironobu

    This paper describes the generation of adaptive gait patterns using new Central Pattern Generators (CPGs) including motor dynamic models for a quadruped robot under various environment. The CPGs act as the flexible oscillators of the joints and make the desired angle of the joints. The CPGs are mutually connected each other, and the sets of their coupling parameters are adjusted by genetic algorithm so that the quadruped robot can realize the stable and adequate gait patterns. As a result of generation, the suitable CPG networks for not only a walking straight gait pattern but also rotation gait patterns are obtained. Experimental results demonstrate that the proposed CPG networks are effective to automatically adjust the adaptive gait patterns for the tested quadruped robot under various environment. Furthermore, the target tracking control based on image processing is achieved by combining the generated gait patterns.

  16. A mechanized gait trainer for restoring gait in nonambulatory subjects.

    PubMed

    Hesse, S; Uhlenbrock, D; Werner, C; Bardeleben, A

    2000-09-01

    To construct an advanced mechanized gait trainer to enable patients the repetitive practice of a gaitlike movement without overstraining therapists. DEVICE: Prototype gait trainer that simulates the phases of gait (by generating a ratio of 40% to 60% between swing and stance phases), supports the subjects according to their ability (lifts the foot during swing phase), and controls the center of mass in the vertical and horizontal directions. Two nonambulatory, hemiparetic patients who regained their walking ability after 4 weeks of daily training on the gait trainer, a 55-year-old woman and a 62-year-old man, both of whom had a first-time ischemic stroke. Four weeks of training, five times a week, each session 20 minutes long. Functional ambulation category (FAC, levels 0-5) to assess gait ability and ground level walking velocity. Rivermead motor assessment score (RMAS, 0-13) to assess gross motor function. Patient 1: At the end of treatment, she was able to walk independently on level ground with use of a walking stick. Her walking velocity had improved from .29m/sec to .59m/sec. Her RMAS score increased from 4 to 10, meaning she could walk at least 40 meters outside, pick up objects from floor, and climb stairs independently. Patient 2: At end of 4-week training, he could walk independently on even surfaces (FAC level 4), using an ankle-foot orthosis and a walking stick. His walking velocity improved from .14m/sec to .63m/sec. His RMAS increased from 3 to 10. The gait trainer enabled severely affected patients the repetitive practice of a gaitlike movement. Future studies may elucidate its value in gait rehabilitation of nonambulatory subjects.

  17. Adaptive control of dynamic balance in human gait on a split-belt treadmill.

    PubMed

    Buurke, Tom J W; Lamoth, Claudine J C; Vervoort, Danique; van der Woude, Lucas H V; den Otter, Rob

    2018-05-17

    Human bipedal gait is inherently unstable and staying upright requires adaptive control of dynamic balance. Little is known about adaptive control of dynamic balance in reaction to long-term, continuous perturbations. We examined how dynamic balance control adapts to a continuous perturbation in gait, by letting people walk faster with one leg than the other on a treadmill with two belts (i.e. split-belt walking). In addition, we assessed whether changes in mediolateral dynamic balance control coincide with changes in energy use during split-belt adaptation. In nine minutes of split-belt gait, mediolateral margins of stability and mediolateral foot roll-off changed during adaptation to the imposed gait asymmetry, especially on the fast side, and returned to baseline during washout. Interestingly, no changes in mediolateral foot placement (i.e. step width) were found during split-belt adaptation. Furthermore, the initial margin of stability and subsequent mediolateral foot roll-off were strongly coupled to maintain mediolateral dynamic balance throughout the gait cycle. Consistent with previous results net metabolic power was reduced during split-belt adaptation, but changes in mediolateral dynamic balance control were not correlated with the reduction of net metabolic power during split-belt adaptation. Overall, this study has shown that a complementary mechanism of relative foot positioning and mediolateral foot roll-off adapts to continuously imposed gait asymmetry to maintain dynamic balance in human bipedal gait. © 2018. Published by The Company of Biologists Ltd.

  18. Synthesis of walking sounds for alleviating gait disturbances in Parkinson's disease.

    PubMed

    Rodger, Matthew W M; Young, William R; Craig, Cathy M

    2014-05-01

    Managing gait disturbances in people with Parkinson's disease is a pressing challenge, as symptoms can contribute to injury and morbidity through an increased risk of falls. While drug-based interventions have limited efficacy in alleviating gait impairments, certain nonpharmacological methods, such as cueing, can also induce transient improvements to gait. The approach adopted here is to use computationally-generated sounds to help guide and improve walking actions. The first method described uses recordings of force data taken from the steps of a healthy adult which in turn were used to synthesize realistic gravel-footstep sounds that represented different spatio-temporal parameters of gait, such as step duration and step length. The second method described involves a novel method of sonifying, in real time, the swing phase of gait using real-time motion-capture data to control a sound synthesis engine. Both approaches explore how simple but rich auditory representations of action based events can be used by people with Parkinson's to guide and improve the quality of their walking, reducing the risk of falls and injury. Studies with Parkinson's disease patients are reported which show positive results for both techniques in reducing step length variability. Potential future directions for how these sound approaches can be used to manage gait disturbances in Parkinson's are also discussed.

  19. Kinematic Analysis of Gait Following Intra-articular Corticosteroid Injection into the Knee Joint with an Acute Exacerbation of Arthritis

    PubMed Central

    Mehta, Saurabh; Szturm, Tony; El-Gabalawy, Hani S.

    2011-01-01

    ABSTRACT Purpose: The objective of this study was to examine the effects of intra-articular corticosteroid injection (ICI) on ipsilateral knee flexion/extension, ankle dorsiflexion/plantarflexion (DF/PF), and hip abduction/adduction (abd/add) during stance phase in people with an acute exacerbation of rheumatoid arthritis (RA) of the knee joint. The study also assessed the effects of ICI on spatiotemporal parameters of gait and functional status in this group. Methods: Nine people with an exacerbation of RA of the knee were recruited. Kinematic and spatiotemporal gait parameters were obtained for each participant. Knee-related functional status was assessed using the Knee injury and Osteoarthritis Outcome Score (KOOS). Spatiotemporal gait parameters and joint angles (knee flexion, ankle DF/PF, hip abd/add) of the affected side were compared pre- and post-ICI. Results: Data for eight people were available for analysis. Median values for knee flexion and ankle PF increased significantly following ICI. Gait parameters of cadence, velocity, bilateral stride length, bilateral step length, step width, double-support percentage, and step time on the affected side also showed improvement. Pain and knee-related functional status as measured by the KOOS showed improvement. Conclusions: This study demonstrated a beneficial short-term effect of ICI on knee-joint movements, gait parameters, and knee-related functional status in people with acute exacerbation of RA of the knee. PMID:22942516

  20. Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments

    PubMed Central

    Geerse, Daphne J.; Coolen, Bert H.; Roerdink, Melvyn

    2015-01-01

    Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect’s 3D body point’s time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point’s time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point’s time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters’ walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman’s bias and limits of agreement. Body point’s time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point’s time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters

  1. Effect of rhythmic auditory cueing on gait in cerebral palsy: a systematic review and meta-analysis.

    PubMed

    Ghai, Shashank; Ghai, Ishan; Effenberg, Alfred O

    2018-01-01

    Auditory entrainment can influence gait performance in movement disorders. The entrainment can incite neurophysiological and musculoskeletal changes to enhance motor execution. However, a consensus as to its effects based on gait in people with cerebral palsy is still warranted. A systematic review and meta-analysis were carried out to analyze the effects of rhythmic auditory cueing on spatiotemporal and kinematic parameters of gait in people with cerebral palsy. Systematic identification of published literature was performed adhering to Preferred Reporting Items for Systematic Reviews and Meta-Analyses and American Academy for Cerebral Palsy and Developmental Medicine guidelines, from inception until July 2017, on online databases: Web of Science, PEDro, EBSCO, Medline, Cochrane, Embase and ProQuest. Kinematic and spatiotemporal gait parameters were evaluated in a meta-analysis across studies. Of 547 records, nine studies involving 227 participants (108 children/119 adults) met our inclusion criteria. The qualitative review suggested beneficial effects of rhythmic auditory cueing on gait performance among all included studies. The meta-analysis revealed beneficial effects of rhythmic auditory cueing on gait dynamic index (Hedge's g =0.9), gait velocity (1.1), cadence (0.3), and stride length (0.5). This review for the first time suggests a converging evidence toward application of rhythmic auditory cueing to enhance gait performance and stability in people with cerebral palsy. This article details underlying neurophysiological mechanisms and use of cueing as an efficient home-based intervention. It bridges gaps in the literature, and suggests translational approaches on how rhythmic auditory cueing can be incorporated in rehabilitation approaches to enhance gait performance in people with cerebral palsy.

  2. The correlation between symptomatic fatigue to definite measures of gait in people with multiple sclerosis.

    PubMed

    Kalron, Alon

    2016-02-01

    There is a general consensus relating to the multidimensional aspects of fatigue in people with multiple sclerosis (PwMS), however, the exact impact of this symptom on gait is not fully understood. Our primary aim was to examine the relationship between definite parameters of gait with self-reported symptomatic fatigue in PwMS according to their level of neurological impairment. Spatio-temporal parameters of gait were studied using an electronic walkway. The Multiple Sclerosis Walking Scale (MSWS-12) questionnaire, a patient-rated measure of walking ability was collected. The Modified Fatigue Impact Scale (MFIS) questionnaire was used to determine the level of symptomatic fatigue. One hundred and one PwMS (61 women) were included in the study analysis. Subjects were divided into mild and moderate neurological impaired groups. Fatigue was correlated with 5 (out of 14) spatiotemporal parameters. However, correlation scores were all <0.35, thus considered as weak correlations. In the mild group, the double support period was the only variable positively correlated to fatigue (Spearman's rho=0.28, P=0.05). In the moderate group, step and stride length were solely negatively correlated to fatigue (Spearman's rho=0.32, P=0.03). In contrast to the definite gait parameters, the MSWS-12 self-questionnaire was moderately positively correlated to the level of fatigue. Scores for the total, mild and moderate groups were 0.54, 0.57 and 0.51; P<0.01, respectively. The present results indicate that modifications in spatio-temporal parameters of gait are not closely related to symptomatic fatigue in PwMS. On the contrary, the self-reported MSWS-12 questionnaire is predisposed to level of fatigue in PwMS. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Assessment of stability during gait in patients with spinal deformity-A preliminary analysis using the dynamic stability margin.

    PubMed

    Simon, Anne-Laure; Lugade, Vipul; Bernhardt, Kathie; Larson, A Noelle; Kaufman, Kenton

    2017-06-01

    Daily living activities are dynamic, requiring spinal motion through space. Current assessment of spinal deformities is based on static measurements from full-spine standing radiographs. Tools to assess dynamic stability during gait might be useful to enhance the standard evaluation. The aim of this study was to evaluate gait dynamic imbalance in patients with spinal deformity using the dynamic stability margin (DSM). Twelve normal subjects and 17 patients with spinal deformity were prospectively recruited. A kinematic 3D gait analysis was performed for the control group (CG) and the spinal deformity group (SDG). The DSM (distance between the extrapolated center of mass and the base of support) and time-distance parameters were calculated for the right and left side during gait. The relationship between DSM and step length was assessed using three variables: gait stability, symmetry, and consistency. Variables' accuracy was validated by a discriminant analysis. Patients with spinal deformity exhibited gait instability according to the DSM (0.25m versus 0.31m) with decreased velocity (1.1ms -1 versus 1.3ms -1 ) and decreased step length (0.32m versus 0.38m). According to the discriminant analysis, gait stability was the more accurate variable (area under the curve AUC=0.98) followed by gait symmetry and consistency. However, gait consistency showed 100% of specificity, sensitivity, and accuracy of precision. The DSM showed that patients with spinal malalignment exhibit decreased gait stability, symmetry, and consistency besides gait time-distance parameter changes. Additional work is required to determine how to apply the DSM for preoperative and postoperative spinal deformity management. Copyright © 2017. Published by Elsevier B.V.

  4. A Highly Backdrivable, Lightweight Knee Actuator for Investigating Gait in Stroke

    PubMed Central

    Sulzer, James S.; Roiz, Ronald A.; Peshkin, Michael A.; Patton, James L.

    2012-01-01

    Many of those who survive a stroke develop a gait disability known as stiff-knee gait (SKG). Characterized by reduced knee flexion angle during swing, people with SKG walk with poor energy efficiency and asymmetry due to the compensatory mechanisms required to clear the foot. Previous modeling studies have shown that knee flexion activity directly before the foot leaves the ground, and this should result in improved knee flexion angle during swing. The goal of this research is to physically test this hypothesis using robotic intervention. We developed a device that is capable of assisting knee flexion torque before swing but feels imperceptible (transparent) for the rest of the gait cycle. This device uses sheathed Bowden cable to control the deflection of a compliant torsional spring in a configuration known as a Series Elastic Remote Knee Actuator (SERKA). In this investigation, we describe the design and evaluation of SERKA, which includes a pilot experiment on stroke subjects. SERKA could supply a substantial torque (12 N· m) in less than 20 ms, with a maximum torque of 41 N·m. The device resisted knee flexion imperceptibly when desired, at less than 1 N·m rms torque during normal gait. With the remote location of the actuator, the user experiences a mass of only 1.2 kg on the knee. We found that the device was capable of increasing both peak knee flexion angle and velocity during gait in stroke subjects. Thus, the SERKA is a valid experimental device that selectively alters knee kinetics and kinematics in gait after stroke. PMID:22563305

  5. Efficacy of gait trainer as an adjunct to traditional physical therapy on walking performance in hemiparetic cerebral palsied children: a randomized controlled trial.

    PubMed

    Gharib, Nevein Mm; El-Maksoud, Gehan M Abd; Rezk-Allah, Soheir S

    2011-10-01

    To assess the effects of additional gait trainer assisted walking exercises on walking performance in children with hemiparetic cerebral palsy. A randomized controlled study. Paediatric physical therapy outpatient clinic. Thirty spastic hemiparetic cerebral palsied children of both sexes (10-13 years - 19 girls and 11 boys). Children were randomly assigned into two equal groups; experimental and control groups. Participants in both groups received a traditional physical therapy exercise programme. Those in the experimental group received additional gait trainer based walking exercises which aimed to improve walking performance. Treatment was provided three times per week for three successive months. Children received baseline and post-treatment assessments using Biodex Gait Trainer 2 assessment device to evaluate gait parameters including: average step length, walking speed, time on each foot (% of gait cycle) and ambulation index. Children in the experimental group showed a significant improvement as compared with those in the control group. The ambulation index was 75.53±7.36 (11.93 ± 2.89 change score) for the experimental group and 66.06 ± 5.48 (2.13 ± 4.43 change score) for the control group (t = 3.99 and P = 0.0001). Time of support for the affected side was 42.4 ± 3.37 (7 ± 2.20 change score) for the experimental group and 38.06 ± 4.63 (3.33 ± 6.25 change score) for the control group (t = 2.92 and P = 0.007). Also, there was a significant improvement in step length and walking speed in both groups. Gait trainer combined with traditional physiotherapy increase the chance of improving gait performance in children with spastic hemiparetic cerebral palsy.

  6. Gait adaptations to awareness and experience of a slip when walking on a cross-slope.

    PubMed

    Lawrence, Daniel; Domone, Sarah; Heller, Ben; Hendra, Timothy; Mawson, Susan; Wheat, Jon

    2015-10-01

    Falls that occur as a result of a slip are one of the leading causes of injuries, particularly in the elderly population. Previous studies have focused on slips that occur on a flat surface. Slips on a laterally sloping surface are important and may be related to different mechanisms of balance recovery. This type of slip might result in different gait adaptations to those previously described on a flat surface, but these adaptations have not been investigated. The aim of this study was to assess whether, when walking on a cross-slope, young adults adapted their gait when made aware of a potential slip, and having experienced a slip. Gait parameters were compared for three conditions--(1) Normal walking; (2) Walking after being made aware of a potential slip (participants were told that a slip may occur); (3) Walking after experiencing a slip (Participants had already experienced at least one slip induced using a soapy contaminant). Gait parameters were only analysed for trials in which there was no slippery contaminant present on the walkway. Stride length and walking velocity were significantly reduced, and stance duration was significantly greater in the awareness and experience conditions compared to normal walking, with no significant differences in any gait parameters between the awareness and experience conditions. In addition, 46.7% of the slip trials resulted in a fall. This is higher than reported for slips induced on a flat surface, suggesting slips on a cross-slope are more hazardous. This would help explain the more cautious gait patterns observed in both the awareness and experience conditions. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Three-dimensional kinematic analysis of upper and lower limb motion during gait of post-stroke patients

    PubMed Central

    Carmo, A.A.; Kleiner, A.F.R.; Lobo da Costa, P.H.; Barros, R.M.L.

    2012-01-01

    The aim of this study was to analyze the alterations of arm and leg movements of patients during stroke gait. Joint angles of upper and lower limbs and spatiotemporal variables were evaluated in two groups: hemiparetic group (HG, 14 hemiparetic men, 53 ± 10 years) and control group (CG, 7 able-bodied men, 50 ± 4 years). The statistical analysis was based on the following comparisons (P ≤ 0.05): 1) right versus left sides of CG; 2) affected (AF) versus unaffected (UF) sides of HG; 3) CG versus both the affected and unaffected sides of HG, and 4) an intracycle comparison of the kinematic continuous angular variables between HG and CG. This study showed that the affected upper limb motion in stroke gait was characterized by a decreased range of motion of the glenohumeral (HG: 6.3 ± 4.5, CG: 20.1 ± 8.2) and elbow joints (AF: 8.4 ± 4.4, UF: 15.6 ± 7.6) on the sagittal plane and elbow joint flexion throughout the cycle (AF: 68.2 ± 0.4, CG: 46.8 ± 2.7). The glenohumeral joint presented a higher abduction angle (AF: 14.2 ± 1.6, CG: 11.5 ± 4.0) and a lower external rotation throughout the cycle (AF: 4.6 ± 1.2, CG: 22.0 ± 3.0). The lower limbs showed typical alterations of the stroke gait patterns. Thus, the changes in upper and lower limb motion of stroke gait were identified. The description of upper limb motion in stroke gait is new and complements gait analysis. PMID:22473324

  8. Gait analysis in anorexia and bulimia nervosa.

    PubMed

    Cimolin, Veronica; Galli, Manuela; Vismara, Luca; Vimercati, Sara Laura; Precilios, Helmer; Cattani, Laila; Fabris De Souza, Shirley; Petroni, Maria Letizia; Capodaglio, Paolo

    2013-09-13

    Anorexia (AN) and Bulimia Nervosa (BN) are two common eating disorders, which appear to share some reduced motor capacities, such as a reduced balance. The presence and the extent of other motor disorders have not been investigated in a comprehensive way. The aim of this study was to quantify gait pattern in AN and BN individuals in order to ascertain possible differences from the normality range and provide novel data for developing some evidence-based rehabilitation strategies. Nineteen AN patients (age 30.16+9.73) and 20 BN patients (age 26.8+8.41) were assessed with quantitative 3D computerized Gait Analysis. Results were compared with a group of healthy controls (CG; 30.7+5.6). AN and BN patients were characterized by different gait strategies compared to CG. Spatio-temporal parameters indicated shorter step length, with AN showing the shortest values. AN walked slower than BN and CG. As for kinematics, AN and BN showed a nonphysiologic pattern at pelvis and hip level on the sagittal and frontal plane, with BN yielding the most abnormal values. Both AN and BN patients were characterized by high ankle plantar flexion capacity at toe-off when compared to CG. As for ankle kinetics, both AN and BN showed physiologic patterns. Stiffness at hip level was close to CG in both pathologic groups; at the ankle level, stiffness was significantly decreased in both groups, with AN displaying lower values. Both AN and BN were characterized by an altered gait pattern compared to CG. Biomechanical differences were evident mainly at pelvis and hip level. Loss of lean mass may lead to musculoskeletal adaptation, ultimately causing alterations in the gait pattern.

  9. Functional asymmetry of gait in children and youth with low-grade scoliosis.

    PubMed

    Nowotny-Czupryna, Olga; Nowotny, Janusz; Brzek, Anna; Czupryna, Krzysztof

    2006-04-28

    Background. Compensation for abnormal alignment of body parts in scoliosis may occur above or below the pelvis. This manifests as dislocation of body parts or changes in the angular composition of the lower limbs. Compensation for unbalanced body arrangement through changes in pelvic tilt and lower limb joints are typically reflected in the gait pattern of the person with scoliosis. The aim of our research was to determine whether and how improper body arrangement in the frontal plane is reflected in the gait pattern of children and youth with lower degree scolioses. Material and method. Children and youth with scolioses of varying grade were examined. In addition to photogrammetric body posture examination, three-dimensional gait analysis was performed during particular gait phases. For each examined child the results of this analysis were compared to the posture parameters. Results. Varying signs of gait asymmetry were observed in the whole group of children and youth with scoliosis. The symptoms were connected with both general gait attributes (unisommetry and unisochrony) and further gait markers. The most obvious changes were observed in pelvis rotation during the swing phase and excessive pelvis elevation during the mid-stance phase. These deviations did not correlate significantly with the results of the static examination. Conclusions. The gait asymmetries observed in children and youth with low-grade scoliosis are non-specific, and probably depend on the individual capabilities of each person to compensate for deficiencies.

  10. Lack of maintenance of gait pattern as measured by instrumental methods suggests psychogenic gait.

    PubMed

    Merello, Marcelo; Ballesteros, Diego; Rossi, Malco; Arena, Julieta; Crespo, Marcos; Cervio, Andres; Cuello Oderiz, Carolina; Rivero, Alberto; Cerquetti, Daniel; Risk, Marcelo; Balej, Jorge

    2012-01-01

    Fluctuation is a common feature of all psychogenic gait disorder (PGD) patterns. Whether this fluctuation involves only the degree of impairment or whether it affects the gait pattern itself remains an interesting question. We hypothesize that, on repeated measurements, both normal and abnormal gait may present quantitative differences while maintaining their basic underlying pattern; conversely, in psychogenic gait, the basic pattern appears not to be preserved. Using an optoelectronic system, data acquired from 19 normal subjects and 66 patients were applied to train a neural network (NN) and subsequently classify gait patterns into four different groups (normal, ataxic, spastic-paraparetic and parkinsonian). Five patients who fulfilled clinical criteria for psychogenic gait and six controls were then prospectively evaluated on two separate occasions, three months apart. Normal controls and ataxic, parkinsonian or spastic patients were correctly identified by the NN, and categorized within the corresponding groups at baseline as well as at a three-month follow-up evaluation. NN analysis showed that after three months, no PGD patient preserved the gait pattern detected at baseline, even though this finding was not clinically apparent. Modification of gait pattern detected by repeated kinematic measurement and NN analysis could suggest the presence of PGD, particularly in difficult-to-diagnose cases.

  11. Does footwear type impact the number of steps required to reach gait steady state?: an innovative look at the impact of foot orthoses on gait initiation.

    PubMed

    Najafi, Bijan; Miller, Daniel; Jarrett, Beth D; Wrobel, James S

    2010-05-01

    Many studies have attempted to better elucidate the effect of foot orthoses on gait dynamics. To our knowledge, most previous studies exclude the first few steps of gait and begin analysis at steady state walking. These unanalyzed steps of gait may contain important information about the dynamic and complex processes required to achieve equilibrium for a given gait velocity. The purpose of this study was to quantify gait initiation and determine how many steps were required to reach steady state walking under three footwear conditions: barefoot, habitual shoes, and habitual shoes with a prefabricated foot orthoses. Fifteen healthy subjects walked 50m at habitual speed in each condition. Wearing habitual shoes with the prefabricated orthoses enabled subjects to reach steady state walking in fewer steps (3.5 steps+/-2.0) compared to the barefoot condition (5.2 steps+/-3.0; p=0.02) as well as compared to the habitual shoes condition (4.7 steps+/-1.6; p=0.05). Interestingly, the subjects' dynamic medial-lateral balance was significantly improved (22%, p<0.05) by using foot orthoses compared to other footwear conditions. These findings suggest that foot orthoses may help individuals reach steady state more quickly and with a better dynamic balance in the medial-lateral direction, independent of foot type. The findings of this pilot study may open new avenues for objectively assessing the impact of prescription footwear on dynamic balance and spatio-temporal parameters of gait. Further work to better assess the impact of foot orthoses on gait initiation in patients suffering from gait and instability pathologies may be warranted. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Clinical usefulness of the virtual reality-based postural control training on the gait ability in patients with stroke.

    PubMed

    Park, Yu-Hyung; Lee, Chi-Ho; Lee, Byoung-Hee

    2013-01-01

    This study is a single blind randomized controlled trial to determine the effect of virtual reality-based postural control training on the gait ability in patients with chronic stroke. Sixteen subjects were randomly assigned to either experimental group (VR, n= 8) or control group (CPT, n= 8). Subjects in both groups received conventional physical therapy for 60 min per day, five days per week during a period of four weeks. Subjects in the VR group received additional augmented reality-based training for 30 min per day, three days per week during a period of four weeks. The subjects were evaluated one week before and after participating in a four week training and follow-up at one month post-training. Data derived from the gait analyses included spatiotemporal gait parameters, 10 meters walking test (10 mWT). In the gait parameters, subjects in the VR group showed significant improvement, except for cadence at post-training and follow-up within the experimental group. However, no obvious significant improvement was observed within the control group. In between group comparisons, the experimental group (VR group) showed significantly greater improvement only in stride length compared with the control group (P< 0.05), however, no significant difference was observed in other gait parameters. In conclusion, we demonstrate significant improvement in gait ability in chronic stroke patients who received virtual reality based postural control training. These findings suggest that virtual reality (VR) postural control training using real-time information may be a useful approach for enhancement of gait ability in patients with chronic stroke.

  13. Altered spatiotemporal characteristics of gait in older adults with chronic low back pain.

    PubMed

    Hicks, Gregory E; Sions, J Megan; Coyle, Peter C; Pohlig, Ryan T

    2017-06-01

    Previous studies in older adults have identified that chronic low back pain (CLBP) is associated with slower gait speed. Given that slower gait speed is a predictor of greater morbidity and mortality among older adults, it is important to understand the underlying spatiotemporal characteristics of gait among older adults with CLBP. The purposes of this study were to determine (1) if there are differences in spatiotemporal parameters of gait between older adults with and without CLBP during self-selected and fast walking and (2) whether any of these gait characteristics are correlated with performance of a challenging walking task, e.g. stair negotiation. Spatiotemporal characteristics of gait were evaluated using a computerized walkway in 54 community-dwelling older adults with CLBP and 54 age- and sex-matched healthy controls. Older adults with CLBP walked slower than their pain-free peers during self-selected and fast walking. After controlling for body mass index and gait speed, step width was significantly greater in the CLBP group during the fast walking condition. Within the CLBP group, step width and double limb support time are significantly correlated with stair ascent/descent times. From a clinical perspective, these gait characteristics, which may be indicative of balance performance, may need to be addressed to improve overall gait speed, as well as stair-climbing performance. Future longitudinal studies confirming our findings are needed, as well as investigations focused on developing interventions to improve gait speed and decrease subsequent risk of mobility decline. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. The impact of Nordic walking training on the gait of the elderly.

    PubMed

    Ben Mansour, Khaireddine; Gorce, Philippe; Rezzoug, Nasser

    2018-03-27

    The purpose of the current study was to define the impact of regular practice of Nordic walking on the gait of the elderly. Thereby, we aimed to determine whether the gait characteristics of active elderly persons practicing Nordic walking are more similar to healthy adults than that of the sedentary elderly. Comparison was made based on parameters computed from three inertial sensors during walking at a freely chosen velocity. Results showed differences in gait pattern in terms of the amplitude computed from acceleration and angular velocity at the lumbar region (root mean square), the distribution (Skewness) quantified from the vertical and Euclidean norm of the lumbar acceleration, the complexity (Sample Entropy) of the mediolateral component of lumbar angular velocity and the Euclidean norm of the shank acceleration and angular velocity, the regularity of the lower limbs, the spatiotemporal parameters and the variability (standard deviation) of stance and stride durations. These findings reveal that the pattern of active elderly differs significantly from sedentary elderly of the same age while similarity was observed between the active elderly and healthy adults. These results advance that regular physical activity such as Nordic walking may counteract the deterioration of gait quality that occurs with aging.

  15. Simulation of gait and gait initiation associated with body oscillating behavior in the gravity environment on the moon, mars and Phobos.

    PubMed

    Brenière, Y

    2001-04-01

    A double-inverted pendulum model of body oscillations in the frontal plane during stepping [Brenière and Ribreau (1998) Biol Cybern 79: 337-345] proposed an equivalent model for studying the body oscillating behavior induced by step frequency in the form of: (1) a kinetic body parameter, the natural body frequency (NBF), which contains gravity and which is invariable for humans, (2) a parametric function of frequency, whose parameter is the NBF, which explicates the amplitude ratio of center of mass to center of foot pressure oscillation, and (3) a function of frequency which simulates the equivalent torque necessary for the control of the head-arms-trunk segment oscillations. Here, this equivalent model is used to simulate the duration of gait initiation, i.e., the duration necessary to initiate and execute the first step of gait in subgravity, as well as to calculate the step frequencies that would impose the same minimum and maximum amplitudes of the oscillating responses of the body center of mass, whatever the gravity value. In particular, this simulation is tested under the subgravity conditions of the Moon, Mars, and Phobos, where gravity is 1/6, 3/8, and 1/1600 times that on the Earth, respectively. More generally, the simulation allows us to establish and discuss the conditions for gait adaptability that result from the biomechanical constraints particular to each gravity system.

  16. Spatio-temporal and kinematic gait analysis in patients with Frontotemporal dementia and Alzheimer's disease through 3D motion capture.

    PubMed

    Rucco, Rosaria; Agosti, Valeria; Jacini, Francesca; Sorrentino, Pierpaolo; Varriale, Pasquale; De Stefano, Manuela; Milan, Graziella; Montella, Patrizia; Sorrentino, Giuseppe

    2017-02-01

    Alzheimer's disease (AD) and behavioral variant of Frontotemporal Dementia (bvFTD) are characterized respectively by atrophy in the medial temporal lobe with memory loss and prefrontal and anterior temporal degeneration with dysexecutive syndrome. In this study, we hypothesized that specific gait patterns are induced by either frontal or temporal degeneration. To test this hypothesis, we studied the gait pattern in bvFTD (23) and AD (22) patients in single and dual task ("motor" and "cognitive") conditions. To detect subtle alterations, we performed motion analysis estimating both spatio-temporal parameters and joint excursions. In the single task condition, the bvFTD group was more unstable and slower compared to healthy subjects, while only two stability parameters were compromised in the AD group. During the motor dual task, both velocity and stability parameters worsened further in the bvFTD group. In the same experimental conditions, AD patients showed a significantly lower speed and stride length than healthy subjects. During the cognitive dual task, a further impairment of velocity and stability parameters was observed in the bvFTD group. Interestingly, during the cognitive dual task, the gait performance of the AD group markedly deteriorated, as documented by the impairment of more indices of velocity and stability. Finally, the kinematic data of thigh, knee, and ankle were more helpful in revealing gait impairment than the spatio-temporal parameters alone. In conclusion, our data showed that the dysexecutive syndrome induces specific gait alterations. Furthermore, our results suggest that the gait worsens in the AD patients when the cognitive resources are stressed. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Contributions of metabolic and temporal costs to human gait selection.

    PubMed

    Summerside, Erik M; Kram, Rodger; Ahmed, Alaa A

    2018-06-01

    Humans naturally select several parameters within a gait that correspond with minimizing metabolic cost. Much less is understood about the role of metabolic cost in selecting between gaits. Here, we asked participants to decide between walking or running out and back to different gait specific markers. The distance of the walking marker was adjusted after each decision to identify relative distances where individuals switched gait preferences. We found that neither minimizing solely metabolic energy nor minimizing solely movement time could predict how the group decided between gaits. Of our twenty participants, six behaved in a way that tended towards minimizing metabolic energy, while eight favoured strategies that tended more towards minimizing movement time. The remaining six participants could not be explained by minimizing a single cost. We provide evidence that humans consider not just a single movement cost, but instead a weighted combination of these conflicting costs with their relative contributions varying across participants. Individuals who placed a higher relative value on time ran faster than individuals who placed a higher relative value on metabolic energy. Sensitivity to temporal costs also explained variability in an individual's preferred velocity as a function of increasing running distance. Interestingly, these differences in velocity both within and across participants were absent in walking, possibly due to a steeper metabolic cost of transport curve. We conclude that metabolic cost plays an essential, but not exclusive role in gait decisions. © 2018 The Author(s).

  18. Evaluation of the effectiveness of a novel gait trainer in increasing the functionality of individuals with motor impairment: A case series.

    PubMed

    Raveh, Eitan; Schwartz, Isabella; Karniel, Naama; Portnoy, Sigal

    2017-10-16

    Regaining the ability to independently ambulate following a physical disability can increase functional ability and participation of patients in daily life. Gait trainers are assistive devices that enable body support and provide safety during gait. However, most conventional gait trainers are pre-configured to a constant position, therefore not suitable for practicing sit-to-stand function, and require assistance from a caregiver in order to mount the device from a sitting position. We therefore evaluated the effectiveness of a dynamically-adjusting gait trainer, designed to provide independence and safety during gait and various activities, in both lab setting and at home in four subjects (one female, three males, ages 32-79 years) with limited ambulation. Spatiotemporal parameters and gait symmetry were recorded, as well as activity levels, actual use of device, and satisfaction. Although gait parameters and physical activity levels were not notably improved, and in one case were worsened, three subjects reported positive experience with the gait trainer. The new gait trainer may have advantages in supporting users with limited mobility during walking and various functions and decrease the risk for falls. A longer practice time and individual fitting process are recommended for better accommodation to the new possibilities.

  19. Correlations between Berg balance scale and gait speed in individuals with stroke wearing ankle-foot orthoses - a pilot study.

    PubMed

    Kobayashi, Toshiki; Leung, Aaron K L; Akazawa, Yasushi; Hutchins, Stephen W

    2016-01-01

    The Berg balance scale (BBS) is commonly used to assess balancing ability in patients with stroke. The BBS may be a good candidate for clinical assessment prior to orthotic intervention, if it correlates well with outcome measures such as gait speed. The purpose of this study was to investigate the correlation between the BBS measured prior to walking with an ankle-foot orthosis (AFO) and specific temporal-spatial parameters of gait when walking with an AFO donned. Eight individuals with chronic stroke participated in this study. Balancing ability was assessed using the BBS, while temporal-spatial parameters of gait (gait speed, bilateral step length, stride length and step width) were measured using a three-dimensional motion analysis system. The correlations between the BBS and gait parameters were investigated using a non-parametric Kendall's Tau (τ) correlation analysis. The BBS showed correlations with gait speed (τ = 0.64, p < 0.05), the step length of the affected side (τ = 0.74, p < 0.05), and the stride length (τ = 0.64, p < 0.05). Assessment of the BBS prior to AFO prescription may potentially help clinicians to estimate the gait speed achievable following orthotic intervention in patients with stroke. Implications for Rehabilitation Assessment of the BBS prior to AFO prescription may help orthotists to estimate the gait speed following an orthotic intervention in patients with stroke. Assessment of the BBS prior to AFO prescription may help orthotists to understand overall balance and postural control abilities in patients with stroke. A larger scale multifactorial analysis is warranted to confirm the results of this pilot study.

  20. Gait Analysis From a Single Ear-Worn Sensor: Reliability and Clinical Evaluation for Orthopaedic Patients.

    PubMed

    Jarchi, Delaram; Lo, Benny; Wong, Charence; Ieong, Edmund; Nathwani, Dinesh; Yang, Guang-Zhong

    2016-08-01

    Objective assessment of detailed gait patterns after orthopaedic surgery is important for post-surgical follow-up and rehabilitation. The purpose of this paper is to assess the use of a single ear-worn sensor for clinical gait analysis. A reliability measure is devised for indicating the confidence level of the estimated gait events, allowing it to be used in free-walking environments and for facilitating clinical assessment of orthopaedic patients after surgery. Patient groups prior to or following anterior cruciate ligament (ACL) reconstruction and knee replacement were recruited to assess the proposed method. The ability of the sensor for detailed longitudinal analysis is demonstrated with a group of patients after lower limb reconstruction by considering parameters such as temporal and force-related gait asymmetry derived from gait events. The results suggest that the ear-worn sensor can be used for objective gait assessments of orthopaedic patients without the requirement and expense of an elaborate laboratory setup for gait analysis. It significantly simplifies the monitoring protocol and opens the possibilities for home-based remote patient assessment.

  1. Gait characteristics after gait-oriented rehabilitation in chronic stroke.

    PubMed

    Peurala, Sinikka H; Titianova, Ekaterina B; Mateev, Plamen; Pitkänen, Kauko; Sivenius, Juhani; Tarkka, Ina M

    2005-01-01

    To assess the effects of rehabilitation in thirty-seven ambulatory patients with chronic stroke during three weeks in-patient rehabilitation period. In the intervention group, each patient received 75 min physiotherapy daily every workday including 20 minutes in the electromechanical gait trainer with body-weight support (BWS). In the control group, each patient participated in 45 min conventional physiotherapy daily. Motor ability was assessed with the first five items of the Modified Motor Assessment Scale (MMAS1-5) and ten meters walking speed. Spatio-temporal gait characteristics were recorded with an electrical walkway. The MMAS1-5 (p<0.0005 and p=0.005) and ten meters walking time (p<0.0005 and p=0.006) improved in both groups. The improvements in MMAS1-5 and ten meters walking time did not differ between the groups (p=0.217 and p=0.195). Specific gait characteristics improved only in the intervention group, as seen in increased Functional Ambulation Profile score (p=0.023), velocity (p=0.023), the step lengths (affected side, p=0.011, non-affected side p=0.040), the stride lengths (p=0.018, p=0.006) and decreased step-time differential (p=0.043). Furthermore, all gait characteristics and other motor abilities remained in the discharge level at the six months in the intervention group. It appears that BWS training gives a long-lasting benefit in gait qualities even in chronic stroke patients.

  2. Effects of obesity on gait pattern in young individuals with Down syndrome.

    PubMed

    Galli, Manuela; Cimolin, Veronica; Rigoldi, Chiara; Condoluci, Claudia; Albertini, Giorgio

    2015-03-01

    In individuals with Down syndrome (DS), the prevalence of obesity is widespread; despite this, there are no experimental studies on the effect of obesity on gait strategy in DS individuals. The aim of this study is to assess the clinical gait analysis of a group of obese individuals with DS and a group of nonobese individuals with DS to determine whether obesity produces a different gait pattern in these participants. In addition, although females and males share a similar mass, they are characterized by different fat distribution and/or accumulation; thus, the presence of differences between females and males within the two DS groups was investigated. Gait analysis data of a group of 78 young individuals with DS and 20 normal-weight participants in the 5-18-year age range were considered. Among DS individuals, 40 were classified as obese (obese DS group), whereas 38 were classified as normal weight (nonobese groups). A three-dimensional gait analysis was carried out using an optoelectronic system, force platforms and video recording. Spatiotemporal, kinematic and kinetic parameters were identified and calculated for each participant. Our results show that most of the parameters were similar in the two groups of DS participants; the only differences were in terms of stance duration, longer in the obese DS group and dorsiflexion ability during the swing phase, which was limited in the obese DS group. The two DS groups were significantly different in terms of ankle stiffness (Ka index): both groups were characterized by reduced values compared with the control group, but the obese group presented lower values with respect to nonobese participants. The data showed that females were characterized by significant modifications of gait pattern compared with males in both groups, in particular, at proximal levels, such as the hip and the pelvis. Our findings indicate that the presence of obesity exerts effects on gait pattern in DS individuals and in particular on ankle

  3. Gait in adolescent idiopathic scoliosis: kinematics and electromyographic analysis

    PubMed Central

    Banse, X.; Mousny, M.; Detrembleur, C.

    2009-01-01

    Adolescent idiopathic scoliosis (AIS) is a progressive growth disease that affects spinal anatomy, mobility, and left-right trunk symmetry. Consequently, AIS can modify human locomotion. Very few studies have investigated a simple activity like walking in a cohort of well-defined untreated patients with scoliosis. The first goal of this study is to evaluate the effects of scoliosis and scoliosis severity on kinematic and electromyographic (EMG) gait variables compared to an able-bodied population. The second goal is to look for any asymmetry in these parameters during walking. Thirteen healthy girls and 41 females with untreated AIS, with left thoracolumbar or lumbar primary structural curves were assessed. AIS patients were divided into three clinical subgroups (group 1 < 20°, group 2 between 20 and 40°, and group 3 > 40°). Gait analysis included synchronous bilateral kinematic and EMG measurements. The subjects walked on a treadmill at 4 km/h (comfortable speed). The tridimensional (3D) shoulder, pelvis, and lower limb motions were measured using 22 reflective markers tracked by four infrared cameras. The EMG timing activity was measured using bipolar surface electrodes on quadratus lumborum, erector spinae, gluteus medius, rectus femoris, semitendinosus, tibialis anterior, and gastrocnemius muscles. Statistical comparisons (ANOVA) were performed across groups and sides for kinematic and EMG parameters. The step length was reduced in AIS compared to normal subjects (7% less). Frontal shoulder, pelvis, and hip motion and transversal hip motion were reduced in scoliosis patients (respectively, 21, 27, 28, and 22% less). The EMG recording during walking showed that the quadratus lumborum, erector spinae, gluteus medius, and semitendinosus muscles contracted during a longer part of the stride in scoliotic patients (46% of the stride) compared with normal subjects (35% of the stride). There was no significant difference between scoliosis groups 1, 2, and 3 for

  4. Gait in adolescent idiopathic scoliosis: kinematics and electromyographic analysis.

    PubMed

    Mahaudens, P; Banse, X; Mousny, M; Detrembleur, C

    2009-04-01

    Adolescent idiopathic scoliosis (AIS) is a progressive growth disease that affects spinal anatomy, mobility, and left-right trunk symmetry. Consequently, AIS can modify human locomotion. Very few studies have investigated a simple activity like walking in a cohort of well-defined untreated patients with scoliosis. The first goal of this study is to evaluate the effects of scoliosis and scoliosis severity on kinematic and electromyographic (EMG) gait variables compared to an able-bodied population. The second goal is to look for any asymmetry in these parameters during walking. Thirteen healthy girls and 41 females with untreated AIS, with left thoracolumbar or lumbar primary structural curves were assessed. AIS patients were divided into three clinical subgroups (group 1 < 20 degrees, group 2 between 20 and 40 degrees, and group 3 > 40 degrees). Gait analysis included synchronous bilateral kinematic and EMG measurements. The subjects walked on a treadmill at 4 km/h (comfortable speed). The tridimensional (3D) shoulder, pelvis, and lower limb motions were measured using 22 reflective markers tracked by four infrared cameras. The EMG timing activity was measured using bipolar surface electrodes on quadratus lumborum, erector spinae, gluteus medius, rectus femoris, semitendinosus, tibialis anterior, and gastrocnemius muscles. Statistical comparisons (ANOVA) were performed across groups and sides for kinematic and EMG parameters. The step length was reduced in AIS compared to normal subjects (7% less). Frontal shoulder, pelvis, and hip motion and transversal hip motion were reduced in scoliosis patients (respectively, 21, 27, 28, and 22% less). The EMG recording during walking showed that the quadratus lumborum, erector spinae, gluteus medius, and semitendinosus muscles contracted during a longer part of the stride in scoliotic patients (46% of the stride) compared with normal subjects (35% of the stride). There was no significant difference between scoliosis groups 1

  5. Subliminal gait initiation deficits in REM sleep behavior disorder: a harbinger of freezing of gait?

    PubMed Central

    Alibiglou, L.; Videnovic, A.; Planetta, P.J.; Vaillancourt, D.E.; MacKinnon, C.D.

    2016-01-01

    Background Muscle activity during REM sleep is markedly increased in people with REM sleep behavior disorder (RBD) and people with Parkinson’s disease (PD) who have freezing of gait. This study examined if individuals with RBD, who do not have a diagnosis of PD, show abnormalities in gait initiation that resemble the impairments observed in PD and whether there is a relationship between these deficits and the level of REM sleep without atonia. Methods Gait initiation and polysomnography studies were conducted in four groups of 10 subjects each: RBD, PD with and without freezing of gait and control subjects. Results Significant reductions were seen in the posterior shift of the center of pressure during the propulsive phase of gait initiation in the RBD and PD with freezing of gait groups compared with controls and PD non-freezers. These reductions negatively correlated with the amount of REM sleep without atonia. The duration of the initial dorsiflexor muscle burst during gait initiation was significantly reduced in both PD groups and the RBD cohort. Conclusions These results provide evidence that people with RBD, prior to a diagnosis of a degenerative neurologic disorder, show alterations in the coupling of posture and gait similar to those seen in PD. The correlation between increased REM sleep without atonia and deficits in forward propulsion during the push-off phase of gait initiation suggests that abnormities in the regulation of muscle tone during REM sleep may be related to the pathogenesis of freezing of gait. PMID:27250871

  6. Effects of Design Variants in Lower-Limb Prostheses on Gait Synergy

    PubMed Central

    Pitkin, Mark R.

    2016-01-01

    A lower-limb prosthesis is the mechanical device with which an amputee’s residual limb interacts with the walking surface. The pressure and shear forces that affect the residuum due to prosthesis use are the sources of pain, residual-limb skin problems and gait deviations. Direct approaches to reducing these problems include improving fit, alignment technique and socket design as well as increasing cushioning with socket liners. A summary of typical malalignments and their consequences is presented. The malalignments are considered sources of excessive moments applied to the residuum, which simplifies the analysis of a patient’s gait. A better design of prosthetic joints could improve prosthetic gait. This article addresses the key mechanical parameter of prosthetic joints, namely the dependence “moment of resistance/angle of deflection.” A mathematical model has been developed that links stresses on the residuum in transtibial amputees with the moment of resistance in the prosthetic ankle at the critical gait phases. Analysis of the model yields a substantial decrease in stresses on the residuum during the most demanding, load-bearing phase of stance if the moment of resistance in the ankle is similar to that seen in the biological ankle joint. Gait study shows use of the experimental rolling-joint prosthetic foot more closely simulates normal gait synergy than the SACH foot. PMID:27087763

  7. Quantitative assessment of the effects of 6 months of adapted physical activity on gait in people with multiple sclerosis: a randomized controlled trial.

    PubMed

    Pau, Massimiliano; Corona, Federica; Coghe, Giancarlo; Marongiu, Elisabetta; Loi, Andrea; Crisafulli, Antonio; Concu, Alberto; Galli, Manuela; Marrosu, Maria Giovanna; Cocco, Eleonora

    2018-01-01

    The purpose of this study is to quantitatively assess the effect of 6 months of supervised adapted physical activity (APA i.e. physical activity designed for people with special needs) on spatio-temporal and kinematic parameters of gait in persons with Multiple Sclerosis (pwMS). Twenty-two pwMS with Expanded Disability Status Scale scores ranging from 1.5 to 5.5 were randomly assigned either to the intervention group (APA, n = 11) or the control group (CG, n = 11). The former underwent 6 months of APA consisting of 3 weekly 60-min sessions of aerobic and strength training, while CG participants were engaged in no structured PA program. Gait patterns were analyzed before and after the training using three-dimensional gait analysis by calculating spatio-temporal parameters and concise indexes of gait kinematics (Gait Profile Score - GPS and Gait Variable Score - GVS) as well as dynamic Range of Motion (ROM) of hip, knee, and ankle joints. The training originated significant improvements in stride length, gait speed and cadence in the APA group, while GPS and GVS scores remained practically unchanged. A trend of improvement was also observed as regard the dynamic ROM of hip, knee, and ankle joints. No significant changes were observed in the CG for any of the parameters considered. The quantitative analysis of gait supplied mixed evidence about the actual impact of 6 months of APA on pwMS. Although some improvements have been observed, the substantial constancy of kinematic patterns of gait suggests that the full transferability of the administered training on the ambulation function may require more specific exercises. Implications for rehabilitation Adapted Physical Activity (APA) is effective in improving spatio-temporal parameters of gait, but not kinematics, in people with multiple sclerosis. Dynamic range of motion during gait is increased after APA. The full transferability of APA on the ambulation function may require specific exercises rather than

  8. Validation of a commercial inertial sensor system for spatiotemporal gait measurements in children.

    PubMed

    Lanovaz, Joel L; Oates, Alison R; Treen, Tanner T; Unger, Janelle; Musselman, Kristin E

    2017-01-01

    Although inertial sensor systems are becoming a popular tool for gait analysis in both healthy and pathological adult populations, there are currently no data on the validity of these systems for use with children. The purpose of this study was to validate spatiotemporal data from a commercial inertial sensor system (MobilityLab) in typically-developing children. Data from 10 children (5 males; 3.0-8.3 years, mean=5.1) were collected simultaneously from MobilityLab and 3D motion capture during gait at self-selected and fast walking speeds. Spatiotemporal parameters were compared between the two methods using a Bland-Altman method. The results indicate that, while the temporal gait measurements were similar between the two systems, MobilityLab demonstrated a consistent bias with respect to measurement of the spatial data (stride length). This error is likely due to differences in relative leg length and gait characteristics in children compared to the MobilityLab adult reference population used to develop the stride length algorithm. A regression-based equation was developed based on the current data to correct the MobilityLab stride length output. The correction was based on leg length, stride time, and shank range-of-motion, each of which were independently associated with stride length. Once the correction was applied, all of the spatiotemporal parameters evaluated showed good agreement. The results of this study indicate that MobilityLab is a valid tool for gait analysis in typically-developing children. Further research is needed to determine the efficacy of this system for use in children suffering from pathologies that impact gait mechanics. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Balzac and human gait analysis.

    PubMed

    Collado-Vázquez, S; Carrillo, J M

    2015-05-01

    People have been interested in movement analysis in general, and gait analysis in particular, since ancient times. Aristotle, Hippocrates, Galen, Leonardo da Vinci and Honoré de Balzac all used observation to analyse the gait of human beings. The purpose of this study is to compare Honoré de Balzac's writings with a scientific analysis of human gait. Honoré de Balzac's Theory of walking and other works by that author referring to gait. Honoré de Balzac had an interest in gait analysis, as demonstrated by his descriptions of characters which often include references to their way of walking. He also wrote a treatise entitled Theory of walking (Théorie de la demarche) in which he employed his keen observation skills to define gait using a literary style. He stated that the walking process is divided into phases and listed the factors that influence gait, such as personality, mood, height, weight, profession and social class, and also provided a description of the correct way of walking. Balzac considered gait analysis to be very important and this is reflected in both his character descriptions and Theory of walking, his analytical observation of gait. In our own technology-dominated times, this serves as a reminder of the importance of observation. Copyright © 2011 Sociedad Española de Neurología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Falls, Cognitive Impairment, and Gait Performance: Results From the GOOD Initiative.

    PubMed

    Allali, Gilles; Launay, Cyrille P; Blumen, Helena M; Callisaya, Michele L; De Cock, Anne-Marie; Kressig, Reto W; Srikanth, Velandai; Steinmetz, Jean-Paul; Verghese, Joe; Beauchet, Olivier

    2017-04-01

    Falls are highly prevalent in individuals with cognitive decline. The complex relationship between falls and cognitive decline (including both subtype and severity of dementia) and the influence of gait disorders have not been studied. This study aimed to examine the association between the subtype (Alzheimer disease [AD] versus non-AD) and the severity (from preclinical to moderate dementia) of cognitive impairment and falls, and to establish an association between falls and gait parameters during the course of dementia. Multicenter cross-sectional study. "Gait, cOgnitiOn & Decline" (GOOD) initiative. A total of 2496 older adults (76.6 ± 7.6 years; 55.0% women) were included in this study (1161 cognitively healthy individuals [CHI], 529 patients with mild cognitive impairment [MCI], 456 patients with mild dementia, and 350 with moderate dementia) from 7 countries. Falls history was collected retrospectively at baseline in each study. Gait speed and stride time variability were recorded at usual walking pace with the GAITRite system. The prevalence of individuals who fall was 50% in AD and 64% in non-AD; whereas it was 25% in CHIs. Only mild and moderate non-AD dementia were associated with an increased risk for falls in comparison with CHI. Higher stride time variability was associated with falls in older adults without dementia (CHI and each MCI subgroup) and mild non-AD dementia, whereas lower gait speed was associated with falls in all participant groups, except in mild AD dementia. When gait speed was adjusted for, higher stride time variability was associated with falls only in CHIs (odds ratio 1.14; P = .012), but not in MCI or in patients with dementia. These findings suggest that non-AD, but not AD dementia, is associated with increased falls in comparison with CHIs. The association between gait parameters and falls also differs across cognitive status, suggesting different mechanisms leading to falls in older individuals with dementia in comparison

  11. Gait and risk of falls associated with frontal cognitive functions at different stages of Alzheimer's disease.

    PubMed

    Coelho, Flávia Gomes de Melo; Stella, Florindo; de Andrade, Larissa Pires; Barbieri, Fabio Augusto; Santos-Galduróz, Ruth Ferreira; Gobbi, Sebastião; Costa, José Luiz Riani; Gobbi, Lilian Teresa Bucken

    2012-09-01

    The decline in frontal cognitive functions contributes to alterations of gait and increases the risk of falls in patients with dementia, a category which included Alzheimer's disease (AD). The objective of the present study was to compare the gait parameters and the risk of falls among patients at different stages of AD, and to relate these variables with cognitive functions. This is a cross-sectional study with 23 patients with mild and moderate AD. The Clinical Dementia Rating was used to classify the dementia severity. The kinematic parameters of gait (cadence, stride length, and stride speed) were analyzed under two conditions: (a) single task (free gait) and (b) dual task (walking and counting down). The risk of falls was evaluated using the Timed Up-and-Go test. The frontal cognitive functions were evaluated using the Frontal Assessment Battery (FAB), the Clock Drawing Test (CDT) and the Symbol Search Subtest. The patients who were at the moderate stage suffered reduced performance in their stride length and stride speed in the single task and had made more counting errors in the dual task and still had a higher fall risk. Both the mild and the moderate patients exhibited significant decreases in stride length, stride speed and cadence in the dual task. Was detected a significant correlation between CDT, FAB, and stride speed in the dual task condition. We also found a significant correlation between subtest Similarities, FAB and cadence in the dual task condition. The dual task produced changes in the kinematic parameters of gait for the mild and moderate AD patients and the gait alterations are related to frontal cognitive functions, particularly executive functions.

  12. Gait analysis in children with cerebral palsy.

    PubMed

    Armand, Stéphane; Decoulon, Geraldo; Bonnefoy-Mazure, Alice

    2016-12-01

    Cerebral palsy (CP) children present complex and heterogeneous motor disorders that cause gait deviations.Clinical gait analysis (CGA) is needed to identify, understand and support the management of gait deviations in CP. CGA assesses a large amount of quantitative data concerning patients' gait characteristics, such as video, kinematics, kinetics, electromyography and plantar pressure data.Common gait deviations in CP can be grouped into the gait patterns of spastic hemiplegia (drop foot, equinus with different knee positions) and spastic diplegia (true equinus, jump, apparent equinus and crouch) to facilitate communication. However, gait deviations in CP tend to be a continuum of deviations rather than well delineated groups. To interpret CGA, it is necessary to link gait deviations to clinical impairments and to distinguish primary gait deviations from compensatory strategies.CGA does not tell us how to treat a CP patient, but can provide objective identification of gait deviations and further the understanding of gait deviations. Numerous treatment options are available to manage gait deviations in CP. Generally, treatments strive to limit secondary deformations, re-establish the lever arm function and preserve muscle strength.Additional roles of CGA are to better understand the effects of treatments on gait deviations. Cite this article: Armand S, Decoulon G, Bonnefoy-Mazure A. Gait analysis in children with cerebral palsy. EFORT Open Rev 2016;1:448-460. DOI: 10.1302/2058-5241.1.000052.

  13. Gait analysis in patients with chronic obstructive pulmonary disease: a systematic review.

    PubMed

    Zago, Matteo; Sforza, Chiarella; Bonardi, Daniela Rita; Guffanti, Enrico Eugenio; Galli, Manuela

    2018-03-01

    Gait instability is a major fall-risk factor in patients with chronic obstructive pulmonary disease (COPD). Clinical gait analysis is a reliable tool to predict fall onsets. However, controversy still exists on gait impairments associated with COPD. Thus, the aims of this review were to evaluate the current understanding of spatiotemporal, kinematic and kinetic gait features in patients with COPD. In line with PRISMA guidelines, a systematic literature search was performed throughout Web of Science, PubMed Medline, Scopus, PEDro and Scielo databases. We considered observational cross-sectional studies evaluating gait features in patients with COPD as their primary outcome. Risk of bias and applicability of these papers were assessed according to the QUADAS-2 tool. Seven articles, cross-sectional studies published from 2011 to 2017, met the inclusion criteria. Sample size of patients with COPD ranged 14-196 (mean age range: 64-75 years). The main reported gait abnormalities were reduced step length and cadence, and altered variability of spatiotemporal parameters. Only subtle biomechanical changes were reported at the ankle level. A convincing mechanistic link between such gait impairments and falls in patients with COPD is still lacking. The paucity of studies, small sample sizes, gender and disease status pooling were the main risk of biases affecting the results uncertainty. Two research directions emerged: stricter cohorts characterization in terms of COPD phenotype and longitudinal studies. Quantitative assessment of gait would identify abnormalities and sensorimotor postural deficiencies that in turn may lead to better falling prevention strategies in COPD. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Effect of Trunk Sagittal Attitude on Shoulder, Thorax and Pelvis Three-Dimensional Kinematics in Able-Bodied Subjects during Gait

    PubMed Central

    Leardini, Alberto; Berti, Lisa; Begon, Mickaël; Allard, Paul

    2013-01-01

    It has been shown that an original attitude in forward or backward inclination of the trunk is maintained at gait initiation and during locomotion, and that this affects lower limb loading patterns. However, no studies have shown the extent to which shoulder, thorax and pelvis three-dimensional kinematics are modified during gait due to this sagittal inclination attitude. Thirty young healthy volunteers were analyzed during level walking with video-based motion analysis. Reflecting markers were mounted on anatomical landmarks to form a two-marker shoulder line segment, and a four-marker thorax and pelvis segments. Absolute and relative spatial rotations were calculated, for a total of 11 degrees of freedom. The subjects were divided into two groups of 15 according to the median of mean thorax inclination angle over the gait cycle. Preliminary MANOVA analysis assessed whether gender was an independent variable. Then two-factor nested ANOVA was used to test the possible effect of thorax inclination on body segments, planes of motion and gait periods, separately. There was no significant difference in all anthropometric and spatio-temporal parameters between the two groups, except for subject mass. The three-dimensional kinematics of the thorax and pelvis were not affected by gender. Nested ANOVA revealed group effect in all segment rotations apart those at the pelvis, in the sagittal and frontal planes, and at the push-off. Attitudes in sagittal thorax inclination altered trunk segments kinematics during gait. Subjects with a backward thorax showed less thorax-to-pelvis motion, but more shoulder-to-thorax and thorax-to-laboratory motion, less motion in flexion/extension and in lateral bending, and also less motion during push-off. This contributes to the understanding of forward propulsion and sideways load transfer mechanisms, fundamental for the maintenance of balance and the risk of falling. PMID:24204763

  15. Effect of trunk sagittal attitude on shoulder, thorax and pelvis three-dimensional kinematics in able-bodied subjects during gait.

    PubMed

    Leardini, Alberto; Berti, Lisa; Begon, Mickaël; Allard, Paul

    2013-01-01

    It has been shown that an original attitude in forward or backward inclination of the trunk is maintained at gait initiation and during locomotion, and that this affects lower limb loading patterns. However, no studies have shown the extent to which shoulder, thorax and pelvis three-dimensional kinematics are modified during gait due to this sagittal inclination attitude. Thirty young healthy volunteers were analyzed during level walking with video-based motion analysis. Reflecting markers were mounted on anatomical landmarks to form a two-marker shoulder line segment, and a four-marker thorax and pelvis segments. Absolute and relative spatial rotations were calculated, for a total of 11 degrees of freedom. The subjects were divided into two groups of 15 according to the median of mean thorax inclination angle over the gait cycle. Preliminary MANOVA analysis assessed whether gender was an independent variable. Then two-factor nested ANOVA was used to test the possible effect of thorax inclination on body segments, planes of motion and gait periods, separately. There was no significant difference in all anthropometric and spatio-temporal parameters between the two groups, except for subject mass. The three-dimensional kinematics of the thorax and pelvis were not affected by gender. Nested ANOVA revealed group effect in all segment rotations apart those at the pelvis, in the sagittal and frontal planes, and at the push-off. Attitudes in sagittal thorax inclination altered trunk segments kinematics during gait. Subjects with a backward thorax showed less thorax-to-pelvis motion, but more shoulder-to-thorax and thorax-to-laboratory motion, less motion in flexion/extension and in lateral bending, and also less motion during push-off. This contributes to the understanding of forward propulsion and sideways load transfer mechanisms, fundamental for the maintenance of balance and the risk of falling.

  16. Correlations among measures of knee stiffness, gait performance and complaints in individuals with knee osteoarthritis.

    PubMed

    Oatis, Carol A; Wolff, Edward F; Lockard, Margery A; Michener, Lori A; Robbins, Steven J

    2013-03-01

    Stiffness is a common complaint in individuals with knee osteoarthritis and is a component of the osteoarthritis diagnosis. Yet the relationship between stiffness and function is poorly understood and methods to quantify stiffness are limited. Using a cross-sectional observational design with 66 subjects with knee osteoarthritis, stiffness and damping coefficients were calculated from a relaxed knee oscillation procedure. Gait parameters were measured using an electronic walkway. Self-reported pain, stiffness, and function were measured with the Western Ontario and McMaster Osteoarthritis Index. Correlation and Alexander's normalized-t approximation analyses were used to assess associations among the variables. Subset analysis was performed on subjects with and without tibiofemoral joint crepitus. Slight to moderate correlations existed between stiffness and damping coefficients and most gait parameters ((| r |=0.30-0.56; P<.05) and between Western Ontario and McMaster Osteoarthritis Index scores and all gait parameters (| r |=0.35-0.62; P<.05). The damping coefficient was only slightly associated with patient-rated Western Ontario and McMaster Osteoarthritis Index stiffness subscale scores. Subset analysis revealed significant correlations that differed between those with and without crepitus. These findings suggest that laboratory measured stiffness and damping coefficients, Western Ontario and McMaster Osteoarthritis Index scores and gait-related measurements assess different aspects related to movement in individuals with knee osteoarthritis. Stiffness and damping coefficients may offer the ability to explain gait changes in the knee that are independent of a person's perceptions particularly in the early stages of the disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. [Influence of spinal orthosis on gait and physical functioning in women with postmenopausal osteoporosis].

    PubMed

    Schmidt, K; Hübscher, M; Vogt, L; Klinkmüller, U; Hildebrandt, H D; Fink, M; Banzer, W

    2012-03-01

    Osteoporosis is a widespread chronic bone disease leading to an increased risk of bone fractures. The most common clinical consequences are back pain, hyperkyphosis, limitations of physical functioning and activities of daily living as well as reduced quality of life. Furthermore, osteoporosis is associated with decreased strength and deficits of gait and balance, all together resulting in an increased risk of falls and a subsequent aggravation of fracture risk. Besides pharmaceutical and exercise therapy, back orthoses are increasingly being used in the therapy of osteoporosis and rehabilitation after vertebral fractures. Previous studies have shown that wearing a spinal orthosis results in a reduction of pain as well as improvements of posture and back extensor strength. To date there is no study that has evaluated the effects of a spinal orthosis on gait stability and physical functioning in patients with osteoporosis. Therefore the purpose of the present study was to assess the effects of a spinal orthosis on gait and pain-induced limitations of activities of daily living (ADL) in women with osteoporosis. A total of 69 postmenopausal osteoporotic women with and without vertebral fractures were randomly assigned to receive either a spinal orthosis (Thämert Osteo-med intervention group n=35; average age 74 ± 8.3 years, height 158.3 ± 6.3 cm, weight 62.8 ± 9.6 kg, t-score -2.6  ± 1.0, number of vertebral fractures 1.4 ± 2.0) or to a waiting list control group (n= 34, age 74.1 ± 7.7 years, height 159.6 ± 5.9 cm, weight 65.4 ± 11.3 kg, t-score -2.9± 0.8, number of vertebral fractures: 0.9 ± 1.2). The following outcome measures were collected at baseline and at 3 and 6 months follow-up: gait parameters including gait analysis: velocity, stride length and width, double support time (% of gait cycle) and perceived limitations in activities of daily living (numeric rating scale 1-10; 1=best, 10= worst situation). The ANCOVA indicated a

  18. Speed-Dependent Modulation of the Locomotor Behavior in Adult Mice Reveals Attractor and Transitional Gaits.

    PubMed

    Lemieux, Maxime; Josset, Nicolas; Roussel, Marie; Couraud, Sébastien; Bretzner, Frédéric

    2016-01-01

    Locomotion results from an interplay between biomechanical constraints of the muscles attached to the skeleton and the neuronal circuits controlling and coordinating muscle activities. Quadrupeds exhibit a wide range of locomotor gaits. Given our advances in the genetic identification of spinal and supraspinal circuits important to locomotion in the mouse, it is now important to get a better understanding of the full repertoire of gaits in the freely walking mouse. To assess this range, young adult C57BL/6J mice were trained to walk and run on a treadmill at different locomotor speeds. Instead of using the classical paradigm defining gaits according to their footfall pattern, we combined the inter-limb coupling and the duty cycle of the stance phase, thus identifying several types of gaits: lateral walk, trot, out-of-phase walk, rotary gallop, transverse gallop, hop, half-bound, and full-bound. Out-of-phase walk, trot, and full-bound were robust and appeared to function as attractor gaits (i.e., a state to which the network flows and stabilizes) at low, intermediate, and high speeds respectively. In contrast, lateral walk, hop, transverse gallop, rotary gallop, and half-bound were more transient and therefore considered transitional gaits (i.e., a labile state of the network from which it flows to the attractor state). Surprisingly, lateral walk was less frequently observed. Using graph analysis, we demonstrated that transitions between gaits were predictable, not random. In summary, the wild-type mouse exhibits a wider repertoire of locomotor gaits than expected. Future locomotor studies should benefit from this paradigm in assessing transgenic mice or wild-type mice with neurotraumatic injury or neurodegenerative disease affecting gait.

  19. Adaptive gait responses to awareness of an impending slip during treadmill walking.

    PubMed

    Yang, Feng; Kim, JaeEun; Munoz, Jose

    2016-10-01

    The awareness of potential slip risk has been shown to cause protective changes to human gait during overground walking. It remains unknown if such adaptations to walking pattern also exist when ambulating on a treadmill. This study sought to determine whether and to what extent individuals, when being aware of a potential slip risk during treadmill walking, could adjust their gait pattern to improve their dynamic stability against backward balance loss in response to the impending slip hazard. Fifty-four healthy young subjects (age: 23.9±4.7years) participated in this study. Subjects' gait pattern was measured under two conditions: walking on a treadmill without (or normal walking) and with (or aware walking) the awareness of the potential slip perturbation. During both walking conditions, subjects' full body kinematics were gathered by using a motion capture system. Spatial gait parameters and the dynamic gait stability against backward balance were compared between the two walking conditions. The results revealed that subjects proactively adopted a "cautious gait" during aware walking compared with the normal walking. The cautious gait, which was achieved by taking a shorter step and a more flatfoot landing, positioned the body center of mass closer to the base of support, improving participants' dynamic stability and increasing their resistance against a possible slip-related fall. The finding from this study could provide insights into the dynamic stability control when individuals anticipate potential slip risk during treadmill walking. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Assessment of Gait Characteristics in Total Knee Arthroplasty Patients Using a Hierarchical Partial Least Squares Method.

    PubMed

    Wang, Wei; Ackland, David C; McClelland, Jodie A; Webster, Kate E; Halgamuge, Saman

    2018-01-01

    Quantitative gait analysis is an important tool in objective assessment and management of total knee arthroplasty (TKA) patients. Studies evaluating gait patterns in TKA patients have tended to focus on discrete data such as spatiotemporal information, joint range of motion and peak values of kinematics and kinetics, or consider selected principal components of gait waveforms for analysis. These strategies may not have the capacity to capture small variations in gait patterns associated with each joint across an entire gait cycle, and may ultimately limit the accuracy of gait classification. The aim of this study was to develop an automatic feature extraction method to analyse patterns from high-dimensional autocorrelated gait waveforms. A general linear feature extraction framework was proposed and a hierarchical partial least squares method derived for discriminant analysis of multiple gait waveforms. The effectiveness of this strategy was verified using a dataset of joint angle and ground reaction force waveforms from 43 patients after TKA surgery and 31 healthy control subjects. Compared with principal component analysis and partial least squares methods, the hierarchical partial least squares method achieved generally better classification performance on all possible combinations of waveforms, with the highest classification accuracy . The novel hierarchical partial least squares method proposed is capable of capturing virtually all significant differences between TKA patients and the controls, and provides new insights into data visualization. The proposed framework presents a foundation for more rigorous classification of gait, and may ultimately be used to evaluate the effects of interventions such as surgery and rehabilitation.

  1. Feasibility study of a wearable exoskeleton for children: is the gait altered by adding masses on lower limbs?

    PubMed

    Rossi, Stefano; Colazza, Alessandra; Petrarca, Maurizio; Castelli, Enrico; Cappa, Paolo; Krebs, Hermano Igo

    2013-01-01

    We are designing a pediatric exoskeletal ankle robot (pediatric Anklebot) to promote gait habilitation in children with Cerebral Palsy (CP). Few studies have evaluated how much or whether the unilateral loading of a wearable exoskeleton may have the unwanted effect of altering significantly the gait. The purpose of this study was to evaluate whether adding masses up to 2.5 kg, the estimated overall added mass of the mentioned device, at the knee level alters the gait kinematics. Ten healthy children and eight children with CP, with light or mild gait impairment, walked wearing a knee brace with several masses. Gait parameters and lower-limb joint kinematics were analyzed with an optoelectronic system under six conditions: without brace (natural gait) and with masses placed at the knee level (0.5, 1.0, 1.5, 2.0, 2.5 kg). T-tests and repeated measures ANOVA tests were conducted in order to find noteworthy differences among the trial conditions and between loaded and unloaded legs. No statistically significant differences in gait parameters for both healthy children and children with CP were observed in the five "with added mass" conditions. We found significant differences among "natural gait" and "with added masses" conditions in knee flexion and hip extension angles for healthy children and in knee flexion angle for children with CP. This result can be interpreted as an effect of the mechanical constraint induced by the knee brace rather than the effect associated with load increase. The study demonstrates that the mechanical constraint induced by the brace has a measurable effect on the gait of healthy children and children with CP and that the added mass up to 2.5 kg does not alter the lower limb kinematics. This suggests that wearable devices weighing 25 N or less will not noticeably modify the gait patterns of the population examined here.

  2. l-DOPA and Freezing of Gait in Parkinson’s Disease: Objective Assessment through a Wearable Wireless System

    PubMed Central

    Suppa, Antonio; Kita, Ardian; Leodori, Giorgio; Zampogna, Alessandro; Nicolini, Ettore; Lorenzi, Paolo; Rao, Rosario; Irrera, Fernanda

    2017-01-01

    Freezing of gait (FOG) is a leading cause of falls and fractures in Parkinson’s disease (PD). The episodic and rather unpredictable occurrence of FOG, coupled with the variable response to l-DOPA of this gait disorder, makes the objective evaluation of FOG severity a major clinical challenge in the therapeutic management of patients with PD. The aim of this study was to examine and compare gait, clinically and objectively, in patients with PD, with and without FOG, by means of a new wearable system. We also assessed the effect of l-DOPA on FOG severity and specific spatiotemporal gait parameters in patients with and without FOG. To this purpose, we recruited 28 patients with FOG, 16 patients without FOG, and 16 healthy subjects. In all participants, gait was evaluated clinically by video recordings and objectively by means of the wearable wireless system, during a modified 3-m Timed Up and Go (TUG) test. All patients performed the modified TUG test under and not under dopaminergic therapy (ON and OFF therapy). By comparing instrumental data with the clinical identification of FOG based on offline video-recordings, we also assessed the performance of the wearable system to detect FOG automatically in terms of sensitivity, specificity, positive and negative predictive values, and finally accuracy. TUG duration was longer in patients than in controls, and the amount of gait abnormalities was prominent in patients with FOG compared with those without FOG. l-DOPA improved gait significantly in patients with PD and particularly in patients with FOG mainly by reducing FOG duration and increasing specific spatiotemporal gait parameters. Finally, the overall wireless system performance in automatic FOG detection was characterized by excellent sensitivity (93.41%), specificity (98.51%), positive predictive value (89.55%), negative predictive value (97.31%), and finally accuracy (98.51%). Our study overall provides new information on the beneficial effect of l-DOPA on FOG

  3. Pilot study of atomoxetine in patients with Parkinson's disease and dopa-unresponsive Freezing of Gait.

    PubMed

    Revuelta, Gonzalo J; Embry, Aaron; Elm, Jordan J; Gregory, Chris; Delambo, Amy; Kautz, Steve; Hinson, Vanessa K

    2015-01-01

    Freezing of gait (FoG) is a common and debilitating condition in Parkinson's disease (PD) associated with executive dysfunction. A subtype of FoG does not respond to dopaminergic therapy and may be related to noradrenergic deficiency. This pilot study explores the effects of atomoxetine on gait in PD patients with dopa-unresponsive FoG using a novel paradigm for objective gait assessment. Ten patients with PD and dopa-unresponsive FoG were enrolled in this eight-week open label pilot study. Assessments included an exploratory gait analysis protocol that quantified spatiotemporal parameters during straight-away walking and turning, while performing a dual task. Clinical, and subjective assessments of gait, quality of life, and safety were also administered. The primary outcome was a validated subjective assessment for FoG (FOG-Q). Atomoxetine was well tolerated, however, no significant change was observed in the primary outcome. The gait analysis protocol correlated well with clinical scales, but not with subjective assessments. DBS patients were more likely to increase gait velocity (p = 0.033), and improved in other clinical assessments. Objective gait analysis protocols assessing gait while dual tasking are feasible and useful for this patient population, and may be superior correlates of FoG severity than subjective measures. These findings can inform future trials in this population.

  4. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    PubMed Central

    Knaepen, Kristel; Mierau, Andreas; Swinnen, Eva; Fernandez Tellez, Helio; Michielsen, Marc; Kerckhofs, Eric; Lefeber, Dirk; Meeusen, Romain

    2015-01-01

    In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support). Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force) and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning. PMID:26485148

  5. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    PubMed

    Knaepen, Kristel; Mierau, Andreas; Swinnen, Eva; Fernandez Tellez, Helio; Michielsen, Marc; Kerckhofs, Eric; Lefeber, Dirk; Meeusen, Romain

    2015-01-01

    In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support). Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force) and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning.

  6. Gait-Related Brain Activity in People with Parkinson Disease with Freezing of Gait

    PubMed Central

    Peterson, Daniel S.; Pickett, Kristen A.; Duncan, Ryan; Perlmutter, Joel; Earhart, Gammon M.

    2014-01-01

    Approximately 50% of people with Parkinson disease experience freezing of gait, described as a transient inability to produce effective stepping. Complex gait tasks such as turning typically elicit freezing more commonly than simple gait tasks, such as forward walking. Despite the frequency of this debilitating and dangerous symptom, the brain mechanisms underlying freezing remain unclear. Gait imagery during functional magnetic resonance imaging permits investigation of brain activity associated with locomotion. We used this approach to better understand neural function during gait-like tasks in people with Parkinson disease who experience freezing- “FoG+” and people who do not experience freezing- ”FoG−“. Nine FoG+ and nine FoG− imagined complex gait tasks (turning, backward walking), simple gait tasks (forward walking), and quiet standing during measurements of blood oxygen level dependent (BOLD) signal. Changes in BOLD signal (i.e. beta weights) during imagined walking and imagined standing were analyzed across FoG+ and FoG− groups in locomotor brain regions including supplementary motor area, globus pallidus, putamen, mesencephalic locomotor region, and cerebellar locomotor region. Beta weights in locomotor regions did not differ for complex tasks compared to simple tasks in either group. Across imagined gait tasks, FoG+ demonstrated significantly lower beta weights in the right globus pallidus with respect to FoG−. FoG+ also showed trends toward lower beta weights in other right-hemisphere locomotor regions (supplementary motor area, mesencephalic locomotor region). Finally, during imagined stand, FoG+ exhibited lower beta weights in the cerebellar locomotor region with respect to FoG−. These data support previous results suggesting FoG+ exhibit dysfunction in a number of cortical and subcortical regions, possibly with asymmetric dysfunction towards the right hemisphere. PMID:24595265

  7. A Wearable System for Gait Training in Subjects with Parkinson's Disease

    PubMed Central

    Casamassima, Filippo; Ferrari, Alberto; Milosevic, Bojan; Ginis, Pieter; Farella, Elisabetta; Rocchi, Laura

    2014-01-01

    In this paper, a system for gait training and rehabilitation for Parkinson's disease (PD) patients in a daily life setting is presented. It is based on a wearable architecture aimed at the provision of real-time auditory feedback. Recent studies have, in fact, shown that PD patients can receive benefit from a motor therapy based on auditory cueing and feedback, as happens in traditional rehabilitation contexts with verbal instructions given by clinical operators. To this extent, a system based on a wireless body sensor network and a smartphone has been developed. The system enables real-time extraction of gait spatio-temporal features and their comparison with a patient's reference walking parameters captured in the lab under clinical operator supervision. Feedback is returned to the user in form of vocal messages, encouraging the user to keep her/his walking behavior or to correct it. This paper describes the overall concept, the proposed usage scenario and the parameters estimated for the gait analysis. It also presents, in detail, the hardware-software architecture of the system and the evaluation of system reliability by testing it on a few subjects. PMID:24686731

  8. Intention detection of gait initiation using EMG and kinematic data.

    PubMed

    Wentink, E C; Beijen, S I; Hermens, H J; Rietman, J S; Veltink, P H

    2013-02-01

    Gait initiation in transfemoral amputees (TFA) is different from non-amputees. This is mainly caused by the lack of stability and push-off from the prosthetic leg. Adding control and artificial push-off to the prosthesis may therefore be beneficial to TFA. In this study the feasibility of real-time intention detection of gait initiation was determined by mimicking the TFA situation in non-amputees. EMG and inertial sensor data was measured in 10 non-amputees. Only data available in TFA was used to determine if gait initiation can be predicted in time to control a transfemoral prosthesis to generate push-off and stability. Toe-off and heel-strike of the leading limb are important parameters to be detected, to control a prosthesis and to time push-off. The results show that toe-off and heel-strike of the leading limb can be detected using EMG and kinematic data in non-amputees 130-260 ms in advance. This leaves enough time to control a prosthesis. Based on these results we hypothesize that similar results can be found in TFA, allowing for adequate control of a prosthesis during gait initiation. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Early signs of gait deviation in Duchenne muscular dystrophy.

    PubMed

    Doglio, L; Pavan, E; Pernigotti, I; Petralia, P; Frigo, C; Minetti, C

    2011-12-01

    Most analytical studies found in literature only focus on specific aspects of Duchenne muscular dystrophy (DMD) gait and posture (joint range of motion, standing balance, variations of gait spatial-temporal parameters). Some of them analyze single cases and do not provide a comprehensive evaluation of locomotion. There are few studies about DMD gait patterns, most of them concerning small groups of patients, sometimes not homogeneous, in which the clinical manifestations of the next stages of DMD were present. The goal of our study was to analyze the characteristics of gait patterns in early stage patients, when clinical and functional evaluation do not allow to quantify initial walking worsening or to identify the changes adopted to compensate for muscle weakness. Gait Analysis Laboratory by using a six-camera motion capture system (Vicon, Oxford Metrics, UK), set at a sampling rate of 60 Hz. Subjects were asked to walk barefoot at their usual cadence, along a 10-m walkway, where one force platform (Kistler, Switzerland), embedded in the middle portion of the pathway, measured the foot-ground reaction forces. Retroreflective markers were placed on the subjects according to the protocol described in Davis et al. A group of 15 patients aging from 5 to 6.8 years was compared with a similar age control group composed of 9 healthy children. Spatial and temporal parameters showed significant differences between the two groups: cadence was increased and step length was decreased significantly in the DMD group. We found a significant increase in the range of anterior-posterior pelvic tilt and in pelvic rotation. In the frontal plane there was a tendency for an increased pelvic obliquity. Dynamic range of motion in sagittal plane showed a significant difference at the ankle, with an increased plantarflexion in swing in the dystrophic patients. Maximum dorsiflexion was reduced in the DMD group. Kinetic analysis showed significant differences in power generation and

  10. Gait Kinematic Analysis in Water Using Wearable Inertial Magnetic Sensors.

    PubMed

    Fantozzi, Silvia; Giovanardi, Andrea; Borra, Davide; Gatta, Giorgio

    2015-01-01

    Walking is one of the fundamental motor tasks executed during aquatic therapy. Previous kinematics analyses conducted using waterproofed video cameras were limited to the sagittal plane and to only one or two consecutive steps. Furthermore, the set-up and post-processing are time-consuming and thus do not allow a prompt assessment of the correct execution of the movements during the aquatic session therapy. The aim of the present study was to estimate the 3D joint kinematics of the lower limbs and thorax-pelvis joints in sagittal and frontal planes during underwater walking using wearable inertial and magnetic sensors. Eleven healthy adults were measured during walking both in shallow water and in dry-land conditions. Eight wearable inertial and magnetic sensors were inserted in waterproofed boxes and fixed to the body segments by means of elastic modular bands. A validated protocol (Outwalk) was used. Gait cycles were automatically segmented and selected if relevant intraclass correlation coefficients values were higher than 0.75. A total of 704 gait cycles for the lower limb joints were normalized in time and averaged to obtain the mean cycle of each joint, among participants. The mean speed in water was 40% lower than that of the dry-land condition. Longer stride duration and shorter stride distance were found in the underwater walking. In the sagittal plane, the knee was more flexed (≈ 23°) and the ankle more dorsiflexed (≈ 9°) at heel strike, and the hip was more flexed at toe-off (≈ 13°) in water than on land. On the frontal plane in the underwater walking, smoother joint angle patterns were observed for thorax-pelvis and hip, and ankle was more inversed at toe-off (≈ 7°) and showed a more inversed mean value (≈ 7°). The results were mainly explained by the effect of the speed in the water as supported by the linear mixed models analysis performed. Thus, it seemed that the combination of speed and environment triggered modifications in the

  11. History of cannabis use is associated with altered gait.

    PubMed

    Pearson-Dennett, Verity; Todd, Gabrielle; Wilcox, Robert A; Vogel, Adam P; White, Jason M; Thewlis, Dominic

    2017-09-01

    Despite evidence that cannabinoid receptors are located in movement-related brain regions (e.g., basal ganglia, cerebral cortex, and cerebellum), and that chronic cannabis use is associated with structural and functional brain changes, little is known about the long-term effect of cannabis use on human movement. The aim of the current study was to investigate balance and walking gait in adults with a history of cannabis use. We hypothesised that cannabis use is associated with subtle changes in gait and balance that are insufficient in magnitude for detection in a clinical setting. Cannabis users (n=22, 24±6years) and non-drug using controls (n=22, 25±8years) completed screening tests, a gait and balance test (with a motion capture system and in-built force platforms), and a clinical neurological examination of movement. Compared to controls, cannabis users exhibited significantly greater peak angular velocity of the knee (396±30 versus 426±50°/second, P=0.039), greater peak elbow flexion (53±12 versus 57±7°, P=0.038) and elbow range of motion (33±13 versus 36±10°, P=0.044), and reduced shoulder flexion (41±19 versus 26±16°, P=0.007) during walking gait. However, balance and neurological parameters did not significantly differ between the groups. The results suggest that history of cannabis use is associated with long-lasting changes in open-chain elements of walking gait, but the magnitude of change is not clinically detectable. Further research is required to investigate if the subtle gait changes observed in this population become more apparent with aging and increased cannabis use. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A characterization of Parkinson's disease by describing the visual field motion during gait

    NASA Astrophysics Data System (ADS)

    Trujillo, David; Martínez, Fabio; Atehortúa, Angélica; Alvarez, Charlens; Romero, Eduardo

    2015-12-01

    An early diagnosis of Parkinson's Disease (PD) is crucial towards devising successful rehabilitation programs. Typically, the PD diagnosis is performed by characterizing typical symptoms, namely bradykinesia, rigidity, tremor, postural instability or freezing gait. However, traditional examination tests are usually incapable of detecting slight motor changes, specially for early stages of the pathology. Recently, eye movement abnormalities have correlated with early onset of some neurodegenerative disorders. This work introduces a new characterization of the Parkinson disease by describing the ocular motion during a common daily activity as the gait. This paper proposes a fully automatic eye motion analysis using a dense optical flow that tracks the ocular direction. The eye motion is then summarized using orientation histograms constructed during a whole gait cycle. The proposed approach was evaluated by measuring the χ2 distance between the orientation histograms, showing substantial differences between control and PD patients.

  13. Computational intelligence in gait research: a perspective on current applications and future challenges.

    PubMed

    Lai, Daniel T H; Begg, Rezaul K; Palaniswami, Marimuthu

    2009-09-01

    Our mobility is an important daily requirement so much so that any disruption to it severely degrades our perceived quality of life. Studies in gait and human movement sciences, therefore, play a significant role in maintaining the well-being of our mobility. Current gait analysis involves numerous interdependent gait parameters that are difficult to adequately interpret due to the large volume of recorded data and lengthy assessment times in gait laboratories. A proposed solution to these problems is computational intelligence (CI), which is an emerging paradigm in biomedical engineering most notably in pathology detection and prosthesis design. The integration of CI technology in gait systems facilitates studies in disorders caused by lower limb defects, cerebral disorders, and aging effects by learning data relationships through a combination of signal processing and machine learning techniques. Learning paradigms, such as supervised learning, unsupervised learning, and fuzzy and evolutionary algorithms, provide advanced modeling capabilities for biomechanical systems that in the past have relied heavily on statistical analysis. CI offers the ability to investigate nonlinear data relationships, enhance data interpretation, design more efficient diagnostic methods, and extrapolate model functionality. These are envisioned to result in more cost-effective, efficient, and easy-to-use systems, which would address global shortages in medical personnel and rising medical costs. This paper surveys current signal processing and CI methodologies followed by gait applications ranging from normal gait studies and disorder detection to artificial gait simulation. We review recent systems focusing on the existing challenges and issues involved in making them successful. We also examine new research in sensor technologies for gait that could be combined with these intelligent systems to develop more effective healthcare solutions.

  14. Kinematic Gait Changes Following Serial Casting and Bracing to Treat Toe Walking in a Child With Autism.

    PubMed

    Barkocy, Marybeth; Dexter, James; Petranovich, Colleen

    2017-07-01

    To evaluate the effectiveness of serial casting in a child with autism spectrum disorder (ASD) exhibiting a toe-walking gait pattern with equinus contractures. Although many children with ASD toe walk, little research on physical therapy interventions exists for this population. Serial casting has been validated for use in idiopathic toe walking to increase passive dorsiflexion and improve gait, but not for toe walking in children with ASD. Serial casting followed by ankle-foot orthosis use was implemented to treat a child with ASD who had an obligatory equinus gait pattern. Gait analysis supported improvements in kinematic, spatial, and temporal parameters of gait, and the child maintained a consistent heel-toe gait at 2-year follow-up. STATEMENT OF CONCLUSION AND RECOMMENDATIONS FOR CLINICAL PRACTICE:: Serial casting followed by ankle-foot orthosis use is a viable treatment option for toe walking in children with ASD.

  15. Morphology and the gradient of a symmetric potential predict gait transitions of dogs.

    PubMed

    Wilshin, Simon; Haynes, G Clark; Porteous, Jack; Koditschek, Daniel; Revzen, Shai; Spence, Andrew J

    2017-08-01

    Gaits and gait transitions play a central role in the movement of animals. Symmetry is thought to govern the structure of the nervous system, and constrain the limb motions of quadrupeds. We quantify the symmetry of dog gaits with respect to combinations of bilateral, fore-aft, and spatio-temporal symmetry groups. We tested the ability of symmetries to model motion capture data of dogs walking, trotting and transitioning between those gaits. Fully symmetric models performed comparably to asymmetric with only a [Formula: see text] increase in the residual sum of squares and only one-quarter of the parameters. This required adding a spatio-temporal shift representing a lag between fore and hind limbs. Without this shift, the symmetric model residual sum of squares was [Formula: see text] larger. This shift is related to (linear regression, [Formula: see text], [Formula: see text]) dog morphology. That this symmetry is respected throughout the gaits and transitions indicates that it generalizes outside a single gait. We propose that relative phasing of limb motions can be described by an interaction potential with a symmetric structure. This approach can be extended to the study of interaction of neurodynamic and kinematic variables, providing a system-level model that couples neuronal central pattern generator networks and mechanical models.

  16. Relationship of spasticity to knee angular velocity and motion during gait in cerebral palsy.

    PubMed

    Damiano, Diane L; Laws, Edward; Carmines, Dave V; Abel, Mark F

    2006-01-01

    This study investigated the effects of spasticity in the hamstrings and quadriceps muscles on gait parameters including temporal spatial measures, knee position, excursion and angular velocity in 25 children with spastic diplegic cerebral palsy (CP) as compared to 17 age-matched peers. While subjects were instructed to relax, an isokinetic device alternately flexed and extended the left knee at one of the three constant velocities 30 degrees/s, 60 degrees/s and 120 degrees/s, while surface electromyography (EMG) electrodes over the biceps femoris and the rectus femoris recorded muscle activity. Patients then participated in 3D gait analysis at a self-selected speed. Results showed that, those with CP who exhibited heightened stretch responses (spasticity) in both muscles, had significantly slower knee angular velocities during the swing phase of gait as compared to those with and without CP who did not exhibit stretch responses at the joint and the tested speeds. The measured amount (torque) of the resistance to passive flexion or extension was not related to gait parameters in subjects with CP; however, the rate of change in resistance torque per unit angle change (stiffness) at the fastest test speed of 120 degrees/s showed weak to moderate relationships with knee angular velocity and motion during gait. For the subset of seven patients with CP who subsequently underwent a selective dorsal rhizotomy, knee angular extension and flexion velocity increased post-operatively, suggesting some degree of causality between spasticity and movement speed.

  17. Wearable Device-Based Gait Recognition Using Angle Embedded Gait Dynamic Images and a Convolutional Neural Network.

    PubMed

    Zhao, Yongjia; Zhou, Suiping

    2017-02-28

    The widespread installation of inertial sensors in smartphones and other wearable devices provides a valuable opportunity to identify people by analyzing their gait patterns, for either cooperative or non-cooperative circumstances. However, it is still a challenging task to reliably extract discriminative features for gait recognition with noisy and complex data sequences collected from casually worn wearable devices like smartphones. To cope with this problem, we propose a novel image-based gait recognition approach using the Convolutional Neural Network (CNN) without the need to manually extract discriminative features. The CNN's input image, which is encoded straightforwardly from the inertial sensor data sequences, is called Angle Embedded Gait Dynamic Image (AE-GDI). AE-GDI is a new two-dimensional representation of gait dynamics, which is invariant to rotation and translation. The performance of the proposed approach in gait authentication and gait labeling is evaluated using two datasets: (1) the McGill University dataset, which is collected under realistic conditions; and (2) the Osaka University dataset with the largest number of subjects. Experimental results show that the proposed approach achieves competitive recognition accuracy over existing approaches and provides an effective parametric solution for identification among a large number of subjects by gait patterns.

  18. Wearable Device-Based Gait Recognition Using Angle Embedded Gait Dynamic Images and a Convolutional Neural Network

    PubMed Central

    Zhao, Yongjia; Zhou, Suiping

    2017-01-01

    The widespread installation of inertial sensors in smartphones and other wearable devices provides a valuable opportunity to identify people by analyzing their gait patterns, for either cooperative or non-cooperative circumstances. However, it is still a challenging task to reliably extract discriminative features for gait recognition with noisy and complex data sequences collected from casually worn wearable devices like smartphones. To cope with this problem, we propose a novel image-based gait recognition approach using the Convolutional Neural Network (CNN) without the need to manually extract discriminative features. The CNN’s input image, which is encoded straightforwardly from the inertial sensor data sequences, is called Angle Embedded Gait Dynamic Image (AE-GDI). AE-GDI is a new two-dimensional representation of gait dynamics, which is invariant to rotation and translation. The performance of the proposed approach in gait authentication and gait labeling is evaluated using two datasets: (1) the McGill University dataset, which is collected under realistic conditions; and (2) the Osaka University dataset with the largest number of subjects. Experimental results show that the proposed approach achieves competitive recognition accuracy over existing approaches and provides an effective parametric solution for identification among a large number of subjects by gait patterns. PMID:28264503

  19. Gait disorders in the elderly and dual task gait analysis: a new approach for identifying motor phenotypes.

    PubMed

    Auvinet, Bernard; Touzard, Claude; Montestruc, François; Delafond, Arnaud; Goeb, Vincent

    2017-01-31

    Gait disorders and gait analysis under single and dual-task conditions are topics of great interest, but very few studies have looked for the relevance of gait analysis under dual-task conditions in elderly people on the basis of a clinical approach. An observational study including 103 patients (mean age 76.3 ± 7.2, women 56%) suffering from gait disorders or memory impairment was conducted. Gait analysis under dual-task conditions was carried out for all patients. Brain MRI was performed in the absence of contra-indications. Three main gait variables were measured: walking speed, stride frequency, and stride regularity. For each gait variable, the dual task cost was computed and a quartile analysis was obtained. Nonparametric tests were used for all the comparisons (Wilcoxon, Kruskal-Wallis, Fisher or Chi 2 tests). Four clinical subgroups were identified: gait instability (45%), recurrent falls (29%), memory impairment (18%), and cautious gait (8%). The biomechanical severity of these subgroups was ordered according to walking speed and stride regularity under both conditions, from least to most serious as follows: memory impairment, gait instability, recurrent falls, cautious gait (p < 0.01 for walking speed, p = 0.05 for stride regularity). According to the established diagnoses of gait disorders, 5 main pathological subgroups were identified (musculoskeletal diseases (n = 11), vestibular diseases (n = 6), mild cognitive impairment (n = 24), central nervous system pathologies, (n = 51), and without diagnosis (n = 8)). The dual task cost for walking speed, stride frequency and stride regularity were different among these subgroups (p < 0.01). The subgroups mild cognitive impairment and central nervous system pathologies both showed together a higher dual task cost for each variable compared to the other subgroups combined (p = 0.01). The quartile analysis of dual task cost for stride frequency and stride regularity

  20. Toddle temporal-spatial deviation index: Assessment of pediatric gait.

    PubMed

    Cahill-Rowley, Katelyn; Rose, Jessica

    2016-09-01

    This research aims to develop a gait index for use in the pediatric clinic as well as research, that quantifies gait deviation in 18-22 month-old children: the Toddle Temporal-spatial Deviation Index (Toddle TDI). 81 preterm children (≤32 weeks) with very-low-birth-weights (≤1500g) and 42 full-term TD children aged 18-22 months, adjusted for prematurity, walked on a pressure-sensitive mat. Preterm children were administered the Bayley Scales of Infant Development-3rd Edition (BSID-III). Principle component analysis of TD children's temporal-spatial gait parameters quantified raw gait deviation from typical, normalized to an average(standard deviation) Toddle TDI score of 100(10), and calculated for all participants. The Toddle TDI was significantly lower for preterm versus TD children (86 vs. 100, p=0.003), and lower in preterm children with <85 vs. ≥85 BSID-III motor composite scores (66 vs. 89, p=0.004). The Toddle TDI, which by design plateaus at typical average (BSID-III gross motor 8-12), correlated with BSID-III gross motor (r=0.60, p<0.001) and not fine motor (r=0.08, p=0.65) in preterm children with gross motor scores ≤8, suggesting sensitivity to gross motor development. The Toddle TDI demonstrated sensitivity and specificity to gross motor function in very-low-birth-weight preterm children aged 18-22 months, and has been potential as an easily-administered, revealing clinical gait metric. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Spatiotemporal gait changes with use of an arm swing cueing device in people with Parkinson's disease.

    PubMed

    Thompson, Elizabeth; Agada, Peter; Wright, W Geoffrey; Reimann, Hendrik; Jeka, John

    2017-10-01

    Impaired arm swing is a common motor symptom of Parkinson's disease (PD), and correlates with other gait impairments and increased risk of falls. Studies suggest that arm swing is not merely a passive consequence of trunk rotation during walking, but an active component of gait. Thus, techniques to enhance arm swing may improve gait characteristics. There is currently no portable device to measure arm swing and deliver immediate cues for larger movement. Here we test report pilot testing of such a device, ArmSense (patented), using a crossover repeated-measures design. Twelve people with PD walked in a video-recorded gym space at self-selected comfortable and fast speeds. After baseline, cues were given either visually using taped targets on the floor to increase step length or through vibrations at the wrist using ArmSense to increase arm swing amplitude. Uncued walking then followed, to assess retention. Subjects successfully reached cueing targets on >95% of steps. At a comfortable pace, step length increased during both visual cueing and ArmSense cueing. However, we observed increased medial-lateral trunk sway with visual cueing, possibly suggesting decreased gait stability. In contrast, no statistically significant changes in trunk sway were observed with ArmSense cues compared to baseline walking. At a fast pace, changes in gait parameters were less systematic. Even though ArmSense cues only specified changes in arm swing amplitude, we observed changes in multiple gait parameters, reflecting the active role arm swing plays in gait and suggesting a new therapeutic path to improve mobility in people with PD. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Automated Gait Analysis Through Hues and Areas (AGATHA): a method to characterize the spatiotemporal pattern of rat gait

    PubMed Central

    Kloefkorn, Heidi E.; Pettengill, Travis R.; Turner, Sara M. F.; Streeter, Kristi A.; Gonzalez-Rothi, Elisa J.; Fuller, David D.; Allen, Kyle D.

    2016-01-01

    While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns. PMID:27554674

  3. Automated Gait Analysis Through Hues and Areas (AGATHA): A Method to Characterize the Spatiotemporal Pattern of Rat Gait.

    PubMed

    Kloefkorn, Heidi E; Pettengill, Travis R; Turner, Sara M F; Streeter, Kristi A; Gonzalez-Rothi, Elisa J; Fuller, David D; Allen, Kyle D

    2017-03-01

    While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns.

  4. Gait characteristics of individuals with multiple sclerosis before and after a 6-month aerobic training program.

    PubMed

    Rodgers, M M; Mulcare, J A; King, D L; Mathews, T; Gupta, S C; Glaser, R M

    1999-07-01

    Individuals who have multiple sclerosis (MS) typically experience problems with physical activities such as walking, resulting from the combined effects of skeletal muscle weakness, sensory disturbances, spasticity, gait ataxia, and reduction in aerobic capacity. The aim of this study was to determine whether a 6-mo exercise program designed for aerobic conditioning might also affect gait abnormalities in individuals with MS. Subjects included 18 individuals with MS who presented a range of disability. Passive range of motion (PROM) in the lower limbs was measured and gait analyzed before and after exercise conditioning. Three-dimensional kinematics, ground reaction forces (GRF), and electromyographic information were acquired as subjects walked at self-selected velocities. Hip PROM increased following conditioning. Mean walking velocity, cadence, and posterior shear GRF (push-off force) decreased. During walking, maximum ankle dorsiflexion decreased and ankle plantarflexion increased. Total knee flexion/extension range during the walking cycle decreased slightly as did maximum hip extension. Results suggest this 6-mo training program had minimal effect on gait abnormalities.

  5. A mechanical energy analysis of gait initiation

    NASA Technical Reports Server (NTRS)

    Miller, C. A.; Verstraete, M. C.

    1999-01-01

    The analysis of gait initiation (the transient state between standing and walking) is an important diagnostic tool to study pathologic gait and to evaluate prosthetic devices. While past studies have quantified mechanical energy of the body during steady-state gait, to date no one has computed the mechanical energy of the body during gait initiation. In this study, gait initiation in seven normal male subjects was studied using a mechanical energy analysis to compute total body energy. The data showed three separate states: quiet standing, gait initiation, and steady-state gait. During gait initiation, the trends in the energy data for the individual segments were similar to those seen during steady-state gait (and in Winter DA, Quanbury AO, Reimer GD. Analysis of instantaneous energy of normal gait. J Biochem 1976;9:253-257), but diminished in amplitude. However, these amplitudes increased to those seen in steady-state during the gait initiation event (GIE), with the greatest increase occurring in the second step due to the push-off of the foundation leg. The baseline level of mechanical energy was due to the potential energy of the individual segments, while the cyclic nature of the data was indicative of the kinetic energy of the particular leg in swing phase during that step. The data presented showed differences in energy trends during gait initiation from those of steady state, thereby demonstrating the importance of this event in the study of locomotion.

  6. Quantifying Parkinson's disease progression by simulating gait patterns

    NASA Astrophysics Data System (ADS)

    Cárdenas, Luisa; Martínez, Fabio; Atehortúa, Angélica; Romero, Eduardo

    2015-12-01

    Modern rehabilitation protocols of most neurodegenerative diseases, in particular the Parkinson Disease, rely on a clinical analysis of gait patterns. Currently, such analysis is highly dependent on both the examiner expertise and the type of evaluation. Development of evaluation methods with objective measures is then crucial. Physical models arise as a powerful alternative to quantify movement patterns and to emulate the progression and performance of specific treatments. This work introduces a novel quantification of the Parkinson disease progression using a physical model that accurately represents the main gait biomarker, the body Center of Gravity (CoG). The model tracks the whole gait cycle by a coupled double inverted pendulum that emulates the leg swinging for the single support phase and by a damper-spring System (SDP) that recreates both legs in contact with the ground for the double phase. The patterns generated by the proposed model are compared with actual ones learned from 24 subjects in stages 2,3, and 4. The evaluation performed demonstrates a better performance of the proposed model when compared with a baseline model(SP) composed of a coupled double pendulum and a mass-spring system. The Frechet distance measured differences between model estimations and real trajectories, showing for stages 2, 3 and 4 distances of 0.137, 0.155, 0.38 for the baseline and 0.07, 0.09, 0.29 for the proposed method.

  7. Evaluating alternative gait strategies using evolutionary robotics.

    PubMed

    Sellers, William I; Dennis, Louise A; W -J, Wang; Crompton, Robin H

    2004-05-01

    Evolutionary robotics is a branch of artificial intelligence concerned with the automatic generation of autonomous robots. Usually the form of the robot is predefined and various computational techniques are used to control the machine's behaviour. One aspect is the spontaneous generation of walking in legged robots and this can be used to investigate the mechanical requirements for efficient walking in bipeds. This paper demonstrates a bipedal simulator that spontaneously generates walking and running gaits. The model can be customized to represent a range of hominoid morphologies and used to predict performance parameters such as preferred speed and metabolic energy cost. Because it does not require any motion capture data it is particularly suitable for investigating locomotion in fossil animals. The predictions for modern humans are highly accurate in terms of energy cost for a given speed and thus the values predicted for other bipeds are likely to be good estimates. To illustrate this the cost of transport is calculated for Australopithecus afarensis. The model allows the degree of maximum extension at the knee to be varied causing the model to adopt walking gaits varying from chimpanzee-like to human-like. The energy costs associated with these gait choices can thus be calculated and this information used to evaluate possible locomotor strategies in early hominids.

  8. Hybridization between multi-objective genetic algorithm and support vector machine for feature selection in walker-assisted gait.

    PubMed

    Martins, Maria; Costa, Lino; Frizera, Anselmo; Ceres, Ramón; Santos, Cristina

    2014-03-01

    Walker devices are often prescribed incorrectly to patients, leading to the increase of dissatisfaction and occurrence of several problems, such as, discomfort and pain. Thus, it is necessary to objectively evaluate the effects that assisted gait can have on the gait patterns of walker users, comparatively to a non-assisted gait. A gait analysis, focusing on spatiotemporal and kinematics parameters, will be issued for this purpose. However, gait analysis yields redundant information that often is difficult to interpret. This study addresses the problem of selecting the most relevant gait features required to differentiate between assisted and non-assisted gait. For that purpose, it is presented an efficient approach that combines evolutionary techniques, based on genetic algorithms, and support vector machine algorithms, to discriminate differences between assisted and non-assisted gait with a walker with forearm supports. For comparison purposes, other classification algorithms are verified. Results with healthy subjects show that the main differences are characterized by balance and joints excursion in the sagittal plane. These results, confirmed by clinical evidence, allow concluding that this technique is an efficient feature selection approach. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Feature selection gait-based gender classification under different circumstances

    NASA Astrophysics Data System (ADS)

    Sabir, Azhin; Al-Jawad, Naseer; Jassim, Sabah

    2014-05-01

    This paper proposes a gender classification based on human gait features and investigates the problem of two variations: clothing (wearing coats) and carrying bag condition as addition to the normal gait sequence. The feature vectors in the proposed system are constructed after applying wavelet transform. Three different sets of feature are proposed in this method. First, Spatio-temporal distance that is dealing with the distance of different parts of the human body (like feet, knees, hand, Human Height and shoulder) during one gait cycle. The second and third feature sets are constructed from approximation and non-approximation coefficient of human body respectively. To extract these two sets of feature we divided the human body into two parts, upper and lower body part, based on the golden ratio proportion. In this paper, we have adopted a statistical method for constructing the feature vector from the above sets. The dimension of the constructed feature vector is reduced based on the Fisher score as a feature selection method to optimize their discriminating significance. Finally k-Nearest Neighbor is applied as a classification method. Experimental results demonstrate that our approach is providing more realistic scenario and relatively better performance compared with the existing approaches.

  10. DMRT3 is associated with gait type in Mangalarga Marchador horses, but does not control gait ability.

    PubMed

    Patterson, L; Staiger, E A; Brooks, S A

    2015-04-01

    The Mangalarga Marchador (MM) is a Brazilian horse breed known for a uniquely smooth gait. A recent publication described a mutation in the DMRT3 gene that the authors claim controls the ability to perform lateral patterned gaits (Andersson et al. 2012). We tested 81 MM samples for the DMRT3 mutation using extracted DNA from hair bulbs using a novel RFLP. Horses were phenotypically categorized by their gait type (batida or picada), as recorded by the Brazilian Mangalarga Marchador Breeders Association (ABCCMM). Statistical analysis using the plink toolset (Purcell, 2007) revealed significant association between gait type and the DMRT3 mutation (P = 2.3e-22). Deviation from Hardy-Weinberg equilibrium suggests that selective pressure for gait type is altering allele frequencies in this breed (P = 1.00e-5). These results indicate that this polymorphism may be useful for genotype-assisted selection for gait type within this breed. As both batida and picada MM horses can perform lateral gaits, the DMRT3 mutation is not the only locus responsible for the lateral gait pattern. © 2015 Stichting International Foundation for Animal Genetics.

  11. The effects of additional arm weights on arm-swing magnitude and gait patterns in Parkinson's disease.

    PubMed

    Yoon, Jiyeon; Park, Jinse; Park, Kunbo; Jo, Geunyeol; Kim, Haeyu; Jang, Wooyoung; Kim, Ji Sun; Youn, Jinyoung; Oh, Eung Seok; Kim, Hee-Tae; Youm, Chang Hong

    2016-01-01

    Recently, arm facilitation has been interested in gait rehabilitation. However, there have been few studies concerning arm facilitation in patients with Parkinson's disease (PD). The aim of our study was to investigate the effect of increasing arm weights on gait pattern in patients with PD. Twenty-seven patients with PD were enrolled, and they underwent gait analysis using a three-dimensional motion capture system. Sandbags were applied to the distal forearms in all participants. We compared gait parameters including arm swing, pelvic motion, spatiotemporal data, and relative rotational angle between the weighted and unweighted gaits. The total arm-swing amplitude and pelvic rotation were significantly higher when walking with additional arm weights than without arm weights. Cadence, walking speed, stride length, and swing phase were significantly higher, whereas stride time, double-support time, and stance phase were significantly lower, when walking with additional arm weights than without arm weights. We conclude that adding weights to the arm during walking may facilitate arm and pelvic movements, which results in changes to gait patterns. The therapeutic use of additional arm weights could be considered for gait rehabilitation in PD to improve gait impairment. Arm-swing facilitation using weight load improved gait in Parkinson's disease. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Association of Dual-Task Gait With Incident Dementia in Mild Cognitive Impairment: Results From the Gait and Brain Study.

    PubMed

    Montero-Odasso, Manuel M; Sarquis-Adamson, Yanina; Speechley, Mark; Borrie, Michael J; Hachinski, Vladimir C; Wells, Jennie; Riccio, Patricia M; Schapira, Marcelo; Sejdic, Ervin; Camicioli, Richard M; Bartha, Robert; McIlroy, William E; Muir-Hunter, Susan

    2017-07-01

    Gait performance is affected by neurodegeneration in aging and has the potential to be used as a clinical marker for progression from mild cognitive impairment (MCI) to dementia. A dual-task gait test evaluating the cognitive-motor interface may predict dementia progression in older adults with MCI. To determine whether a dual-task gait test is associated with incident dementia in MCI. The Gait and Brain Study is an ongoing prospective cohort study of community-dwelling older adults that enrolled 112 older adults with MCI. Participants were followed up for 6 years, with biannual visits including neurologic, cognitive, and gait assessments. Data were collected from July 2007 to March 2016. Incident all-cause dementia was the main outcome measure, and single- and dual-task gait velocity and dual-task gait costs were the independent variables. A neuropsychological test battery was used to assess cognition. Gait velocity was recorded under single-task and 3 separate dual-task conditions using an electronic walkway. Dual-task gait cost was defined as the percentage change between single- and dual-task gait velocities: ([single-task gait velocity - dual-task gait velocity]/ single-task gait velocity) × 100. Cox proportional hazard models were used to estimate the association between risk of progression to dementia and the independent variables, adjusted for age, sex, education, comorbidities, and cognition. Among 112 study participants with MCI, mean (SD) age was 76.6 (6.9) years, 55 were women (49.1%), and 27 progressed to dementia (24.1%), with an incidence rate of 121 per 1000 person-years. Slow single-task gait velocity (<0.8 m/second) was not associated with progression to dementia (hazard ratio [HR], 3.41; 95% CI, 0.99-11.71; P = .05)while high dual-task gait cost while counting backward (HR, 3.79; 95% CI, 1.57-9.15; P = .003) and naming animals (HR, 2.41; 95% CI, 1.04-5.59; P = .04) were associated with dementia progression (incidence rate, 155 per

  13. Effects of the addition of functional electrical stimulation to ground level gait training with body weight support after chronic stroke.

    PubMed

    Prado-Medeiros, Christiane L; Sousa, Catarina O; Souza, Andréa S; Soares, Márcio R; Barela, Ana M F; Salvini, Tania F

    2011-01-01

    The addition of functional electrical stimulation (FES) to treadmill gait training with partial body weight support (BWS) has been proposed as a strategy to facilitate gait training in people with hemiparesis. However, there is a lack of studies that evaluate the effectiveness of FES addition on ground level gait training with BWS, which is the most common locomotion surface. To investigate the additional effects of commum peroneal nerve FES combined with gait training and BWS on ground level, on spatial-temporal gait parameters, segmental angles, and motor function. Twelve people with chronic hemiparesis participated in the study. An A1-B-A2 design was applied. A1 and A2 corresponded to ground level gait training using BWS, and B corresponded to the same training with the addition of FES. The assessments were performed using the Modified Ashworth Scale (MAS), Functional Ambulation Category (FAC), Rivermead Motor Assessment (RMA), and filming. The kinematics analyzed variables were mean walking speed of locomotion; step length; stride length, speed and duration; initial and final double support duration; single-limb support duration; swing period; range of motion (ROM), maximum and minimum angles of foot, leg, thigh, and trunk segments. There were not changes between phases for the functional assessment of RMA, for the spatial-temporal gait variables and segmental angles, no changes were observed after the addition of FES. The use of FES on ground level gait training with BWS did not provide additional benefits for all assessed parameters.

  14. Correlation between physical examination and three-dimensional gait analysis in the assessment of rotational abnormalities in children with cerebral palsy.

    PubMed

    Teixeira, Fernando Borge; Ramalho Júnior, Amancio; Morais Filho, Mauro César de; Speciali, Danielli Souza; Kawamura, Catia Miyuki; Lopes, José Augusto Fernandes; Blumetti, Francesco Camara

    2018-01-01

    Objective To evaluate the correlation between physical examination data concerning hip rotation and tibial torsion with transverse plane kinematics in children with cerebral palsy; and to determine which time points and events of the gait cycle present higher correlation with physical examination findings. Methods A total of 195 children with cerebral palsy seen at two gait laboratories from 2008 and 2016 were included in this study. Physical examination measurements included internal hip rotation, external hip rotation, mid-point hip rotation and the transmalleolar axis angle. Six kinematic parameters were selected for each segment to assess hip rotation and shank-based foot rotation. Correlations between physical examination and kinematic measures were analyzed by Spearman correlation coefficients, and a significance level of 5% was considered. Results Comparing physical examination measurements of hip rotation and hip kinematics, we found moderate to strong correlations for all variables (p<0.001). The highest coefficients were seen between the mid-point hip rotation on physical examination and hip rotation kinematics (rho range: 0.48-0.61). Moderate correlations were also found between the transmalleolar axis angle measurement on physical examination and foot rotation kinematics (rho range 0.44-0.56; p<0.001). Conclusion These findings may have clinical implications in the assessment and management of transverse plane gait deviations in children with cerebral palsy.

  15. Musical motor feedback (MMF) in walking hemiparetic stroke patients: randomized trials of gait improvement.

    PubMed

    Schauer, Michael; Mauritz, Karl-Heinz

    2003-11-01

    To demonstrate the effect of rhythmical auditory stimulation in a musical context for gait therapy in hemiparetic stroke patients, when the stimulation is played back measure by measure initiated by the patient's heel-strikes (musical motor feedback). Does this type of musical feedback improve walking more than a less specific gait therapy? The randomized controlled trial considered 23 registered stroke patients. Two groups were created by randomization: the control group received 15 sessions of conventional gait therapy and the test group received 15 therapy sessions with musical motor feedback. Inpatient rehabilitation hospital. Median post-stroke interval was 44 days and the patients were able to walk without technical aids with a speed of approximately 0.71 m/s. Gait velocity, step duration, gait symmetry, stride length and foot rollover path length (heel-on-toe-off distance). The test group showed more mean improvement than the control group: stride length increased by 18% versus 0%, symmetry deviation decreased by 58% versus 20%, walking speed increased by 27% versus 4% and rollover path length increased by 28% versus 11%. Musical motor feedback improves the stroke patient's walk in selected parameters more than conventional gait therapy. A fixed memory in the patient's mind about the song and its timing may stimulate the improvement of gait even without the presence of an external pacemaker.

  16. Race walking gait and its influence on race walking economy in world-class race walkers.

    PubMed

    Gomez-Ezeiza, Josu; Torres-Unda, Jon; Tam, Nicholas; Irazusta, Jon; Granados, Cristina; Santos-Concejero, Jordan

    2018-03-06

    The aim of this study was to determine the relationships between biomechanical parameters of the gait cycle and race walking economy in world-class Olympic race walkers. Twenty-One world-class race walkers possessing the Olympic qualifying standard participated in this study. Participants completed an incremental race walking test starting at 10 km·h -1 , where race walking economy (ml·kg -1 ·km -1 ) and spatiotemporal gait variables were analysed at different speeds. 20-km race walking performance was related to race walking economy, being the fastest race walkers those displaying reduced oxygen cost at a given speed (R = 0.760, p < 0.001). Longer ground contact times, shorter flight times, longer midstance sub-phase and shorter propulsive sub-phase during stance were related to a better race walking economy (moderate effect, p < 0.05). According to the results of this study, the fastest race walkers were more economi cal than the lesser performers. Similarly, shorter flight times are associated with a more efficient race walking economy. Coaches and race walkers should avoid modifying their race walking style by increasing flight times, as it may not only impair economy, but also lead to disqualification.

  17. Advanced Prosthetic Gait Training Tool

    DTIC Science & Technology

    2014-10-01

    AWARD NUMBER: W81XWH-10-1-0870 TITLE: Advanced Prosthetic Gait Training Tool...October 2014 2. REPORT TYPE Annual Report 3. DATES COVERED 20 Sep 2013 to 19 Sep 2014 4. TITLE AND SUBTITLE Advanced Prosthetic Gait Training...produce a computer-based Advanced Prosthetic Gait Training Tool to aid in the training of clinicians at military treatment facilities providing care

  18. Evaluation and management of crouch gait.

    PubMed

    Kedem, Paz; Scher, David M

    2016-02-01

    Crouch gait is defined as excessive ankle dorsiflexion, knee and hip flexion during the stance phase. This gait disorder is common among patients with cerebral palsy. The present article brings an up-to-date literature review on the pathoanatomy, natural history, and treatment of this frequent gait abnormality. Hamstrings are often not shortened in patients with crouch. Patella alta must be addressed if surgery is performed. Surgical correction of joint contractures and lever arm dysfunction can be effectively achieved through a single-event multilevel surgery. Crouch gait is a common gait deviation, often seen among ambulatory diplegic and quadriplegic patients, once they reach the pubertal spurt, when weak muscles can no longer support a toe walking pattern because of rapidly increased weight. This form of gait is highly ineffective and might compromise walking ability over time. The anterior knee is overloaded; pain, extensor mechanism failure, and arthritis might develop. Its progressive nature often requires surgical intervention. The cause of crouch gait is multifactorial, and surgery should be tailored to meet the individual's specific anatomic and physiologic abnormalities.

  19. Group aquatic training improves gait efficiency in adolescents with cerebral palsy.

    PubMed

    Ballaz, Laurent; Plamondon, Suzanne; Lemay, Martin

    2011-01-01

    To evaluate the effect and feasibility of a 10-week group aquatic training programme on gait efficiency in adolescents with cerebral palsy (CP). The secondary purpose was to determine the exercise intensity during aquatic training in a heterogeneous group of adolescents with CP and to investigate the impact of the training programme on the musculoskeletal system. Twelve ambulatory adolescents with spastic CP were recruited. They participated in 20 aquatic training sessions (45 min twice a week). Three physical therapists and a sports teacher supervised the training sessions. Participants wore a heart rate monitor to assess sessions' intensity and a floatation device as appropriate. The primary outcome measure was gait efficiency as measured by the gait energy expenditure index (EEI). The secondary measures were (1) gait spatiotemporal parameters, (2) maximal isometric knee strength and (3) gross motor function. Ten adolescents completed the training programme. No adverse effect was reported. Average exercise intensity was mild to moderate for more than half of the training session. A significant reduction of the EEI and the heart rate during walking was observed following the training programme. No significant change was observed on secondary outcome measures. Group aquatic training increases gait efficiency in adolescents with CP. This improvement is related to systemic cardiorespiratory adaptations. Group aquatic training programme is feasible in adolescents presenting CP at different levels of severity.

  20. Self-perceived gait stability modulates the effect of daily life gait quality on prospective falls in older adults.

    PubMed

    Weijer, R H A; Hoozemans, M J M; van Dieën, J H; Pijnappels, M

    2018-05-01

    Quality of gait during daily life activities and perceived gait stability are both independent risk factors for future falls in older adults. We investigated whether perceived gait stability modulates the association between gait quality and falling in older adults. In this prospective cohort study, we used one-week daily-life trunk acceleration data of 272 adults over 65 years of age. Sample entropy (SE) of the 3D acceleration signals was calculated to quantify daily life gait quality. To quantify perceived gait stability, the level of concern about falling was assessed using the Falls Efficacy Scale international (FES-I) questionnaire and step length, estimated from the accelerometer data. A fall calendar was used to record fall incidence during a six-month follow up period. Logistic regression analyses were performed to study the association between falling and SE, step length or FES-I score, and their interactions. High (i.e., poor) SE in vertical direction was significantly associated with falling. FES-I scores significantly modulated this association, whereas step length did not. Subgroup analyses based on FES-I scores showed that high SE in the vertical direction was a risk factor for falls only in older adults who had a high (i.e. poor) FES-I score. In conclusion, perceived gait stability modulates the association between gait quality and falls in older adults such that an association between gait quality and falling is only present when perceived gait stability is poor. The results of the present study indicate that the effectiveness of interventions for fall prevention, aimed at improving gait quality, may be affected by a modulating effect of perceived gait stability. Results indicate that interventions to reduce falls in older adults might sort most effectiveness in populations with both a poor physiological and psychological status. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Combining gait optimization with passive system to increase the energy efficiency of a humanoid robot walking movement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira, Ana I.; ALGORITMI,University of Minho; Lima, José

    There are several approaches to create the Humanoid robot gait planning. This problem presents a large number of unknown parameters that should be found to make the humanoid robot to walk. Optimization in simulation models can be used to find the gait based on several criteria such as energy minimization, acceleration, step length among the others. The energy consumption can also be reduced with elastic elements coupled to each joint. The presented paper addresses an optimization method, the Stretched Simulated Annealing, that runs in an accurate and stable simulation model to find the optimal gait combined with elastic elements. Finalmore » results demonstrate that optimization is a valid gait planning technique.« less

  2. Gait characteristics of post-poliomyelitis patients: standardization of quantitative data reporting.

    PubMed

    Portnoy, S; Schwartz, I

    2013-10-01

    To evaluate the differences in gait characteristics and gait symmetry of post-polio syndrome (PPS) patients ambulating with or without shoes and between subgroups walking with different walking aids and orthoses, study the correlation of these data with personal data, illness condition, physical health, frequency of using aids and orthotics and frequency of falls, and derive recommendations for standardization of reporting these data. Twenty-six PPS subjects ambulated with their own walking devices. We calculated spatio-temporal parameters and symmetry indices (SI) of gait using a data acquired by a motion capture system. We compared inter-subject differences in gait pattern for PPS groups that differed by questionnaire-obtained data of demographics, physical activity, polio history, falls and walking aids. Additional inter-subject comparisons were performed between normal subjects (n=16), PPS patients walking with shoes with/without an ankle-foot-orthosis (n=11), PPS patients walking with knee-ankle-foot-orthosis (n=5), and PPS patients walking with a walker/crutches (n=10). We also compared intra-subject variability in PPS subjects who were able to repeat the trials barefoot. Our main results show that subjects who reported participating in physical activity twice a week or more had significantly better step time and double support symmetry. Subjects who use walking aids on a daily basis had significantly higher gait cadence and shorter stride time. Also, subjects that do not require knee-ankle-foot orthoses and/or walking aids walked with a smaller base width and better symmetry in stance and swing durations than PPS subjects who require these aids. The gait pattern of PPS patients is related to numerous intrinsic and extrinsic factors. Standardization of the reporting protocol of gait-related data of PPS patients is crucial for patient evaluation and treatment design. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  3. Fractal analyses reveal independent complexity and predictability of gait

    PubMed Central

    Dierick, Frédéric; Nivard, Anne-Laure

    2017-01-01

    Locomotion is a natural task that has been assessed for decades and used as a proxy to highlight impairments of various origins. So far, most studies adopted classical linear analyses of spatio-temporal gait parameters. Here, we use more advanced, yet not less practical, non-linear techniques to analyse gait time series of healthy subjects. We aimed at finding more sensitive indexes related to spatio-temporal gait parameters than those previously used, with the hope to better identify abnormal locomotion. We analysed large-scale stride interval time series and mean step width in 34 participants while altering walking direction (forward vs. backward walking) and with or without galvanic vestibular stimulation. The Hurst exponent α and the Minkowski fractal dimension D were computed and interpreted as indexes expressing predictability and complexity of stride interval time series, respectively. These holistic indexes can easily be interpreted in the framework of optimal movement complexity. We show that α and D accurately capture stride interval changes in function of the experimental condition. Walking forward exhibited maximal complexity (D) and hence, adaptability. In contrast, walking backward and/or stimulation of the vestibular system decreased D. Furthermore, walking backward increased predictability (α) through a more stereotyped pattern of the stride interval and galvanic vestibular stimulation reduced predictability. The present study demonstrates the complementary power of the Hurst exponent and the fractal dimension to improve walking classification. Our developments may have immediate applications in rehabilitation, diagnosis, and classification procedures. PMID:29182659

  4. Effect of normal-walking-pattern-based functional electrical stimulation on gait of the lower extremity in subjects with ischemic stroke: A self controlled study.

    PubMed

    Xu, Benlei; Yan, Tiebin; Yang, Yuanle; Ou, Ruiqing; Huang, Shuping

    2016-01-01

    Functional electrical stimulation is a widely used technique for rehabilitation. To assess the efficacy of walking-pattern-based four-channel functional electric stimulation and its influence on the gait features of stroke patients with hemiplegia. A total of 21 stroke patients with hemiplegia were enrolled into the study. The walking gaits of patients were investigated before, during and after walking-pattern-based FES treatment using the gait analysis system. The changes of gait indexes were comparatively analyzed. After walking-pattern-based FES therapy, the pace, stride rate, gait cycle, and step length of stroke patients with hemiplegia were 50.19 ± 14.45 cm/s, 36.85 ± 5.85 time/min, 1.6643 ± 0.2626 sec, 80.3333 ± 15.1438 cm, respectively. The motion range of hip and knee joint were 47.5238 ± 10.7453, 56.7619 ± 14.5255, respectively. We found these indexes were significantly improved compared with those before FES treatment (P <  0.05). The single swing rate (injured extremity/uninjured extremity) after FES treatment was 1.5589 ± 0.4550. The statistical results showed that the gait cycle, pace, stride rat, and single swing rate (injured extremity/uninjured extremity) were significantly improved after FES treatment (P <  0.05). Our results demonstrate that walking-paradigm based FES we developed is effective for treating stroke patients during rehabilitation.

  5. Differences Between Gait on Stairs and Flat Surfaces in Relation to Fall Risk and Future Falls.

    PubMed

    Wang, Kejia; Delbaere, Kim; Brodie, Matthew A D; Lovell, Nigel H; Kark, Lauren; Lord, Stephen R; Redmond, Stephen J

    2017-11-01

    We used body-worn inertial sensors to quantify differences in semi-free-living gait between stairs and on normal flat ground in older adults, and investigated the utility of assessing gait on these terrains for predicting the occurrence of multiple falls. Eighty-two community-dwelling older adults wore two inertial sensors, on the lower back and the right ankle, during several bouts of walking on flat surfaces and up and down stairs, in between rests and activities of daily living. Derived from the vertical acceleration at the lower back, step rate was calculated from the signal's fundamental frequency. Step rate variability was the width of this fundamental frequency peak from the signal's power spectral density. Movement vigor was calculated at both body locations from the signal variance. Partial Spearman correlations between gait parameters and physiological fall risk factors (components from the Physiological Profile Assessment) were calculated while controlling for age and gender. Overall, anteroposterior vigor at the lower back in stair descent was lower in subjects with longer reaction times. Older adults walked more slowly on stairs, but they were not significantly slower on flat surfaces. Using logistic regression, faster step rate in stair descent was associated with multiple prospective falls over 12 months. No significant associations were shown from gait parameters derived during walking upstairs or on flat surfaces. These results suggest that stair descent gait may provide more insight into fall risk than regular walking and stair ascent, and that further sensor-based investigation into unsupervised gait on different terrains would be valuable.

  6. The contribution of quasi-joint stiffness of the ankle joint to gait in patients with hemiparesis.

    PubMed

    Sekiguchi, Yusuke; Muraki, Takayuki; Kuramatsu, Yuko; Furusawa, Yoshihito; Izumi, Shin-Ichi

    2012-06-01

    The role of ankle joint stiffness during gait in patients with hemiparesis has not been clarified. The purpose of this study was to determine the contribution of quasi-joint stiffness of the ankle joint to spatiotemporal and kinetic parameters regarding gait in patients with hemiparesis due to brain tumor or stroke and healthy individuals. Spatiotemporal and kinetic parameters regarding gait in twelve patients with hemiparesis due to brain tumor or stroke and nine healthy individuals were measured with a 3-dimensional motion analysis system. Quasi-joint stiffness was calculated from the slope of the linear regression of the moment-angle curve of the ankle joint during the second rocker. There was no significant difference in quasi-joint stiffness among both sides of patients and the right side of controls. Quasi-joint stiffness on the paretic side of patients with hemiparesis positively correlated with maximal ankle power (r=0.73, P<0.01) and gait speed (r=0.66, P<0.05). In contrast, quasi-joint stiffness in controls negatively correlated with maximal ankle power (r=-0.73, P<0.05) and gait speed (r=-0.76, P<0.05). Our findings suggested that ankle power during gait might be generated by increasing quasi-joint stiffness in patients with hemiparesis. In contrast, healthy individuals might decrease quasi-joint stiffness to avoid deceleration of forward tilt of the tibia. Our findings might be useful for selecting treatment for increased ankle stiffness due to contracture and spasticity in patients with hemiparesis. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. [Gait characteristics of women with fibromyalgia: a premature aging pattern].

    PubMed

    Góes, Suelen M; Leite, Neiva; de Souza, Ricardo M; Homann, Diogo; Osiecki, Ana C V; Stefanello, Joice M F; Rodacki, André L F

    2014-01-01

    Fibromyalgia is a condition which involves chronic pain. Middle-aged individuals with fibromyalgia seem to exhibit changes in gait pattern, which may prematurely expose them to a gait pattern which resembles that found in the elderly population. To determine the 3D spatial (linear and angular) gait parameters of middle-aged women with fibromyalgia and compare to elderly women without this condition. 25 women (10 in the fibromyalgia group and 15 in the elderly group) volunteered to participate in the study. Kinematics was performed using an optoelectronic system, and linear and angular kinematic variables were determined. There was no difference in walking speed, stride length, cadence, hip, knee and ankle joints range of motion between groups, except the pelvic rotation, in which the fibromyalgia group showed greater rotation (P<0.05) compared to the elderly group. Also, there was a negative correlation with pelvic rotation and gluteus pain (r = -0.69; P<0.05), and between pelvic obliquity and greater trochanter pain (r = -0.69; P<0.05) in the fibromyalgia group. Middle-aged women with fibromyalgia showed gait pattern resemblances to elderly, women, which is characterized by reduced lower limb ROM, stride length and walking speed. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  8. A hippotherapy simulator is effective to shift weight bearing toward the affected side during gait in patients with stroke.

    PubMed

    Sung, Yun-Hee; Kim, Chang-Ju; Yu, Byong-Kyu; Kim, Kyeong-Mi

    2013-01-01

    We investigated whether a hippotherapy simulator has influence on symmetric body weight bearing during gait in patients with stroke. Stroke patients were divided into a control group (n = 10) that received conventional rehabilitation for 60 min/day, 5 times/week for 4 weeks and an experimental group (n = 10) that used a hippotherapy simulator for 15 min/day, 5 times/week for 4 weeks after conventional rehabilitation for 45 min/day. Temporospatial gait assessed using OptoGait and trunk muscles (abdominis and erector spinae on affected side) activity evaluated using surface electromyography during sit-to-stand and gait. Prior to starting the experiment, pre-testing was performed. At the end of the 4-week intervention, we performed post-testing. Activation of the erector spinae in the experimental group was significantly increased compared to that in the control group (p < 0.01), whereas activation of the rectus abdominis decreased during sit-to-stand. Of the gait parameters, load response, single support, total double support, and pre-swing showed significant changes in the experimental group with a hippotherapy simulator compared to control group (p < 0.05). Moreover, activation of the erector spinae and rectus abdominis in gait correlate with changes of gait parameters including load response, single support, total double support, and pre-swing in experimental group. These findings suggest that use of a hippotherapy simulator to patients with stroke can improve asymmetric weight bearing by influencing trunk muscles.

  9. Kinetic and kinematic follow‐up gait analysis in Doberman Pinschers with cervical spondylomyelopathy treated medically and surgically

    PubMed Central

    Smith, Rebecca L.; da Costa, Ronaldo C.

    2018-01-01

    Background The efficacy of treatment of dogs with cervical spondylomyelopathy (CSM) is commonly based on the owner's and clinician's perception of the gait, which is highly subjective and suffers from observer bias. Hypothesis/Objectives To compare selected kinetic and kinematic parameters before and after treatments and to correlate the findings of gait analysis to clinical outcome. Animals Eight Doberman Pinschers with CSM confirmed by magnetic resonsance imaging. Methods Patients were prospectively studied and treated with either medical management (n = 5) or surgery (n = 3). Force plate analysis and 3‐D kinematic motion capture were performed at initial presentation and approximately 8 weeks later. Force plate parameters evaluated included peak vertical force (PVF). Kinematic parameters measured included number of pelvic limb strides, stifle flexion and extension, maximum and minimum thoracic limb distance, truncal sway, and thoracic limb stride duration. Results Kinematic analysis showed that deviation of the spine to the right (truncal sway) was significantly smaller (P < .001) and the degree of right stifle flexion was significantly larger (P = .029) after treatment. Force plate analysis indicated that PVF was significantly different after treatment (P = .049) and the difference of the PVF also was significantly larger (P = .027). However, no correlation was found with either method of gait analysis and clinical recovery. Conclusions and Clinical Importance Kinetic and kinematic gait analysis were able to detect differences in dogs with CSM before and after treatment. A correlation of gait analysis to clinical improvement could not be determined. PMID:29572944

  10. Surface electromyography and plantar pressure changes with novel gait training device in participants with chronic ankle instability.

    PubMed

    Feger, Mark A; Hertel, Jay

    2016-08-01

    Rehabilitation is ineffective at restoring normal gait in chronic ankle instability patients. Our purpose was to determine if a novel gait-training device could decrease plantar pressure on the lateral column of the foot in chronic ankle instability patients. Ten chronic ankle instability patients completed 30s trials of baseline and gait-training walking at a self-selected pace while in-shoe plantar pressure and surface electromyography were recorded from their anterior tibialis, peroneus longus, medial gastrocnemius, and gluteus medius. The gait-training device applied a medially-directed force to the lower leg via elastic bands during the entire gait cycle. Plantar pressure measures of the entire foot and 9 specific regions of the foot as well as surface electromyography root mean square areas were compared between the baseline and gait-training conditions using paired t-tests with a priori level of significance of p≤0.05. The gait-training device decreased pressure time integrals and peak pressures in the lateral midfoot (p=0.003 and p=0.003) and lateral forefoot (p=0.023 and p=0.005), and increased pressure time integrals and peak pressures for the total foot (p=0.030 and p=0.017) and hallux (p=0.005 and p=0.002). The center of pressure was shifted medially during the entire stance phase (p<0.003 for all comparisons) due to increased peroneus longus activity prior to (p=0.002) and following initial contact (p=0.002). The gait-training device decreased pressure on the lateral column of the foot and increased peroneus longus muscle activity. Future research should analyze the efficacy of the gait-training device during gait retraining for chronic ankle instability. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Gait analysis in a mouse model resembling Leigh disease.

    PubMed

    de Haas, Ria; Russel, Frans G; Smeitink, Jan A

    2016-01-01

    Leigh disease (LD) is one of the clinical phenotypes of mitochondrial OXPHOS disorders and also known as sub-acute necrotizing encephalomyelopathy. The disease has an incidence of 1 in 77,000 live births. Symptoms typically begin early in life and prognosis for LD patients is poor. Currently, no clinically effective treatments are available. Suitable animal and cellular models are necessary for the understanding of the neuropathology and the development of successful new therapeutic strategies. In this study we used the Ndufs4 knockout (Ndufs4(-/-)) mouse, a model of mitochondrial complex I deficiency. Ndusf4(-/-) mice exhibit progressive neurodegeneration, which closely resemble the human LD phenotype. When dissecting behavioral abnormalities in animal models it is of great importance to apply translational tools that are clinically relevant. To distinguish gait abnormalities in patients, simple walking tests can be assessed, but in animals this is not easy. This study is the first to demonstrate automated CatWalk gait analysis in the Ndufs4(-/-) mouse model. Marked differences were noted between Ndufs4(-/-) and control mice in dynamic, static, coordination and support parameters. Variation of walking speed was significantly increased in Ndufs4(-/-) mice, suggesting hampered and uncoordinated gait. Furthermore, decreased regularity index, increased base of support and changes in support were noted in the Ndufs4(-/-) mice. Here, we report the ability of the CatWalk system to sensitively assess gait abnormalities in Ndufs4(-/-) mice. This objective gait analysis can be of great value for intervention and drug efficacy studies in animal models for mitochondrial disease. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Compressive tibiofemoral force during crouch gait.

    PubMed

    Steele, Katherine M; Demers, Matthew S; Schwartz, Michael H; Delp, Scott L

    2012-04-01

    Crouch gait, a common walking pattern in individuals with cerebral palsy, is characterized by excessive flexion of the hip and knee. Many subjects with crouch gait experience knee pain, perhaps because of elevated muscle forces and joint loading. The goal of this study was to examine how muscle forces and compressive tibiofemoral force change with the increasing knee flexion associated with crouch gait. Muscle forces and tibiofemoral force were estimated for three unimpaired children and nine children with cerebral palsy who walked with varying degrees of knee flexion. We scaled a generic musculoskeletal model to each subject and used the model to estimate muscle forces and compressive tibiofemoral forces during walking. Mild crouch gait (minimum knee flexion 20-35°) produced a peak compressive tibiofemoral force similar to unimpaired walking; however, severe crouch gait (minimum knee flexion>50°) increased the peak force to greater than 6 times body-weight, more than double the load experienced during unimpaired gait. This increase in compressive tibiofemoral force was primarily due to increases in quadriceps force during crouch gait, which increased quadratically with average stance phase knee flexion (i.e., crouch severity). Increased quadriceps force contributes to larger tibiofemoral and patellofemoral loading which may contribute to knee pain in individuals with crouch gait. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Development of a novel virtual reality gait intervention.

    PubMed

    Boone, Anna E; Foreman, Matthew H; Engsberg, Jack R

    2017-02-01

    Improving gait speed and kinematics can be a time consuming and tiresome process. We hypothesize that incorporating virtual reality videogame play into variable improvement goals will improve levels of enjoyment and motivation and lead to improved gait performance. To develop a feasible, engaging, VR gait intervention for improving gait variables. Completing this investigation involved four steps: 1) identify gait variables that could be manipulated to improve gait speed and kinematics using the Microsoft Kinect and free software, 2) identify free internet videogames that could successfully manipulate the chosen gait variables, 3) experimentally evaluate the ability of the videogames and software to manipulate the gait variables, and 4) evaluate the enjoyment and motivation from a small sample of persons without disability. The Kinect sensor was able to detect stride length, cadence, and joint angles. FAAST software was able to identify predetermined gait variable thresholds and use the thresholds to play free online videogames. Videogames that involved continuous pressing of a keyboard key were found to be most appropriate for manipulating the gait variables. Five participants without disability evaluated the effectiveness for modifying the gait variables and enjoyment and motivation during play. Participants were able to modify gait variables to permit successful videogame play. Motivation and enjoyment were high. A clinically feasible and engaging virtual intervention for improving gait speed and kinematics has been developed and initially tested. It may provide an engaging avenue for achieving thousands of repetitions necessary for neural plastic changes and improved gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. The gait disorder in downbeat nystagmus syndrome.

    PubMed

    Schniepp, Roman; Wuehr, Max; Huth, Sabrina; Pradhan, Cauchy; Schlick, Cornelia; Brandt, Thomas; Jahn, Klaus

    2014-01-01

    Downbeat nystagmus (DBN) is a common form of acquired fixation nystagmus with key symptoms of oscillopsia and gait disturbance. Gait disturbance could be a result of impaired visual feedback due to the involuntary ocular oscillations. Alternatively, a malfunction of cerebellar locomotor control might be involved, since DBN is considered a vestibulocerebellar disorder. Investigation of walking in 50 DBN patients (age 72 ± 11 years, 23 females) and 50 healthy controls (HS) (age 70 ± 11 years, 23 females) using a pressure sensitive carpet (GAITRite). The patient cohort comprised subjects with only ocular motor signs (DBN) and subjects with an additional limb ataxia (DBNCA). Gait investigation comprised different walking speeds and walking with eyes closed. In DBN, gait velocity was reduced (p<0.001) with a reduced stride length (p<0.001), increased base of support (p<0.050), and increased double support (p<0.001). Walking with eyes closed led to significant gait changes in both HS and DBN. These changes were more pronounced in DBN patients (p<0.001). Speed-dependency of gait variability revealed significant differences between the subgroups of DBN and DBNCA (p<0.050). (I) Impaired visual control caused by involuntary ocular oscillations cannot sufficiently explain the gait disorder. (II) The gait of patients with DBN is impaired in a speed dependent manner. (III) Analysis of gait variability allows distinguishing DBN from DBNCA: Patients with pure DBN show a speed dependency of gait variability similar to that of patients with afferent vestibular deficits. In DBNCA, gait variability resembles the pattern found in cerebellar ataxia.

  15. The impact of footwear and walking distance on gait stability in diabetic patients with peripheral neuropathy.

    PubMed

    Najafi, Bijan; Khan, Tahir; Fleischer, Adam; Wrobel, James

    2013-01-01

    We explored gait differences in patients with diabetes and peripheral neuropathy (DPN) and aged-matched controls over short and long walking distances. The potential benefit of footwear for improving gait in patients with DPN was also explored. Twelve patients with DPN and eight controls walked at their habitual speed over short (7 m) and long (20 m) distances under two conditions: barefoot and regular shoes. A validated system of body-worn sensors was used to extract spatiotemporal gait parameters. Neuropathy severity was quantified using vibratory perception threshold measured at the great toe. Gait deterioration in the DPN group was observed during all of the walking trials. However, the difference between patients with DPN and participants in the control group achieved statistical significance only during long walking distance trials. Shod and barefoot double support times were longer in the DPN group during long walking distances (>20%, P = .03). Gait unsteadiness, defined as coefficient of variation of gait velocity, was also significantly higher in the DPN group when barefoot walking over long distances (83%, P = .008). Furthermore, there was a high correlation between neuropathy severity and gait unsteadiness best demonstrated during the barefoot walking/long walking distance condition (r = 0.77, P < .001). The addition of footwear improved gait steadiness in the DPN group by 46% (P = .02). All differences were independent of age, sex, and body mass index (P > .05). This study suggests that gait alteration in patients with DPN is most pronounced while walking barefoot over longer distances and that footwear may improve gait steadiness in patients with DPN.

  16. Brain Activity during Mental Imagery of Gait Versus Gait-Like Plantar Stimulation: A Novel Combined Functional MRI Paradigm to Better Understand Cerebral Gait Control.

    PubMed

    Labriffe, Matthieu; Annweiler, Cédric; Amirova, Liubov E; Gauquelin-Koch, Guillemette; Ter Minassian, Aram; Leiber, Louis-Marie; Beauchet, Olivier; Custaud, Marc-Antoine; Dinomais, Mickaël

    2017-01-01

    Human locomotion is a complex sensorimotor behavior whose central control remains difficult to explore using neuroimaging method due to technical constraints, notably the impossibility to walk with a scanner on the head and/or to walk for real inside current scanners. The aim of this functional Magnetic Resonance Imaging (fMRI) study was to analyze interactions between two paradigms to investigate the brain gait control network: (1) mental imagery of gait, and (2) passive mechanical stimulation of the plantar surface of the foot with the Korvit boots. The Korvit stimulator was used through two different modes, namely an organized ("gait like") sequence and a destructured (chaotic) pattern. Eighteen right-handed young healthy volunteers were recruited (mean age, 27 ± 4.7 years). Mental imagery activated a broad neuronal network including the supplementary motor area-proper (SMA-proper), pre-SMA, the dorsal premotor cortex, ventrolateral prefrontal cortex, anterior insula, and precuneus/superior parietal areas. The mechanical plantar stimulation activated the primary sensorimotor cortex and secondary somatosensory cortex bilaterally. The paradigms generated statistically common areas of activity, notably bilateral SMA-proper and right pre-SMA, highlighting the potential key role of SMA in gait control. There was no difference between the organized and chaotic Korvit sequences, highlighting the difficulty of developing a walking-specific plantar stimulation paradigm. In conclusion, this combined-fMRI paradigm combining mental imagery and gait-like plantar stimulation provides complementary information regarding gait-related brain activity and appears useful for the assessment of high-level gait control.

  17. Modeling and simulation of normal and hemiparetic gait

    NASA Astrophysics Data System (ADS)

    Luengas, Lely A.; Camargo, Esperanza; Sanchez, Giovanni

    2015-09-01

    Gait is the collective term for the two types of bipedal locomotion, walking and running. This paper is focused on walking. The analysis of human gait is of interest to many different disciplines, including biomechanics, human-movement science, rehabilitation and medicine in general. Here we present a new model that is capable of reproducing the properties of walking, normal and pathological. The aim of this paper is to establish the biomechanical principles that underlie human walking by using Lagrange method. The constraint forces of Rayleigh dissipation function, through which to consider the effect on the tissues in the gait, are included. Depending on the value of the factor present in the Rayleigh dissipation function, both normal and pathological gait can be simulated. First of all, we apply it in the normal gait and then in the permanent hemiparetic gait. Anthropometric data of adult person are used by simulation, and it is possible to use anthropometric data for children but is necessary to consider existing table of anthropometric data. Validation of these models includes simulations of passive dynamic gait that walk on level ground. The dynamic walking approach provides a new perspective of gait analysis, focusing on the kinematics and kinetics of gait. There have been studies and simulations to show normal human gait, but few of them have focused on abnormal, especially hemiparetic gait. Quantitative comparisons of the model predictions with gait measurements show that the model can reproduce the significant characteristics of normal gait.

  18. Gait Partitioning Methods: A Systematic Review

    PubMed Central

    Taborri, Juri; Palermo, Eduardo; Rossi, Stefano; Cappa, Paolo

    2016-01-01

    In the last years, gait phase partitioning has come to be a challenging research topic due to its impact on several applications related to gait technologies. A variety of sensors can be used to feed algorithms for gait phase partitioning, mainly classifiable as wearable or non-wearable. Among wearable sensors, footswitches or foot pressure insoles are generally considered as the gold standard; however, to overcome some inherent limitations of the former, inertial measurement units have become popular in recent decades. Valuable results have been achieved also though electromyography, electroneurography, and ultrasonic sensors. Non-wearable sensors, such as opto-electronic systems along with force platforms, remain the most accurate system to perform gait analysis in an indoor environment. In the present paper we identify, select, and categorize the available methodologies for gait phase detection, analyzing advantages and disadvantages of each solution. Finally, we comparatively examine the obtainable gait phase granularities, the usable computational methodologies and the optimal sensor placements on the targeted body segments. PMID:26751449

  19. Gait Partitioning Methods: A Systematic Review.

    PubMed

    Taborri, Juri; Palermo, Eduardo; Rossi, Stefano; Cappa, Paolo

    2016-01-06

    In the last years, gait phase partitioning has come to be a challenging research topic due to its impact on several applications related to gait technologies. A variety of sensors can be used to feed algorithms for gait phase partitioning, mainly classifiable as wearable or non-wearable. Among wearable sensors, footswitches or foot pressure insoles are generally considered as the gold standard; however, to overcome some inherent limitations of the former, inertial measurement units have become popular in recent decades. Valuable results have been achieved also though electromyography, electroneurography, and ultrasonic sensors. Non-wearable sensors, such as opto-electronic systems along with force platforms, remain the most accurate system to perform gait analysis in an indoor environment. In the present paper we identify, select, and categorize the available methodologies for gait phase detection, analyzing advantages and disadvantages of each solution. Finally, we comparatively examine the obtainable gait phase granularities, the usable computational methodologies and the optimal sensor placements on the targeted body segments.

  20. Do Men and Women Walk Differently? A Review and Meta-Analysis of Sex Difference in Non-Pathological Gait Kinematics

    DTIC Science & Technology

    2014-01-01

    Physiotherapy , 2011. 97(3): 182-189. 27. Al-Obaidi, S., et al., Basic gait parameters: a comparison of reference data for normal subjects 20 to 29...et al., Importance of correcting for individual differences in the clinical diagnosis of gait disorders. Physiotherapy , 2012. 98(4): 320-324. 71

  1. Gait and balance disorders in older adults.

    PubMed

    Salzman, Brooke

    2010-07-01

    Gait and balance disorders are common in older adults and are a major cause of falls in this population. They are associated with increased morbidity and mortality, as well as reduced level of function. Common causes include arthritis and orthostatic hypotension; however, most gait and balance disorders involve multiple contributing factors. Most changes in gait are related to underlying medical conditions and should not be considered an inevitable consequence of aging. Physicians caring for older patients should ask at least annually about falls, and should ask about or examine for difficulties with gait and balance at least once. For older adults who report a fall, physicians should ask about difficulties with gait and balance, and should observe for any gait or balance dysfunctions. The Timed Up and Go test is a fast and reliable diagnostic tool. Persons who have difficulty or demonstrate unsteadiness performing the Timed Up and Go test require further assessment, usually with a physical therapist, to help elucidate gait impairments and related functional limitations. The most effective strategy for falls prevention involves a multifactorial evaluation followed by targeted interventions for identified contributing factors. Evidence on the effectiveness of interventions for gait and balance disorders is limited because of the lack of standardized outcome measures determining gait and balance abilities. However, effective options for patients with gait and balance disorders include exercise and physical therapy. (c) 2010 American Academy of Family Physicians.

  2. Gait Analysis Methods: An Overview of Wearable and Non-Wearable Systems, Highlighting Clinical Applications

    PubMed Central

    Muro-de-la-Herran, Alvaro; Garcia-Zapirain, Begonya; Mendez-Zorrilla, Amaia

    2014-01-01

    This article presents a review of the methods used in recognition and analysis of the human gait from three different approaches: image processing, floor sensors and sensors placed on the body. Progress in new technologies has led the development of a series of devices and techniques which allow for objective evaluation, making measurements more efficient and effective and providing specialists with reliable information. Firstly, an introduction of the key gait parameters and semi-subjective methods is presented. Secondly, technologies and studies on the different objective methods are reviewed. Finally, based on the latest research, the characteristics of each method are discussed. 40% of the reviewed articles published in late 2012 and 2013 were related to non-wearable systems, 37.5% presented inertial sensor-based systems, and the remaining 22.5% corresponded to other wearable systems. An increasing number of research works demonstrate that various parameters such as precision, conformability, usability or transportability have indicated that the portable systems based on body sensors are promising methods for gait analysis. PMID:24556672

  3. Changes of cerebrospinal fluid protein concentrations and gait patterns in geriatric normal pressure hydrocephalus patients after ventriculoperitoneal shunting surgery.

    PubMed

    Chen, Carl P C; Huang, Yin-Cheng; Chang, Chen-Nen; Chen, Jean-Lon; Hsu, Chih-Chin; Lin, Wan-Ying

    2018-06-01

    Normal pressure hydrocephalus (NPH) was the first type of dementia ever described that can be treated using ventriculoperitoneal shunting surgery. Three typical clinical symptoms of NPH include gait disturbance, progressive cognitive dysfunction, and urinary incontinence. Although there are articles that have discovered several cerebrospinal fluid (CSF) protein biomarkers associated with NPH; however, studies examining individual and total protein concentrations from the ventricular CSF before and after shunting surgery are lacking. This study used proteomics to calculate the CSF individual and total protein concentrations before, and one week, one month and three months after the shunting surgery. Parameters of cadence, step length, walking speed, and percentages of single- and double-limb support in a gait cycle were measured. Protein concentrations associated with anti-oxidation, aging, and in the prevention of neurotoxic agent production increased by at least 2-folds after the surgery, indicating that the brain may become less susceptible to neurodegeneration. These proteins were alpha-1B-glycoprotein, apolipoproteins A-1 & A-IV, prostaglandin-H2 D-isomerase, alpha-1-antitrypsin, and serotransferrin. In gait analysis, lower cadence, decreased double-limb support, longer step length, and increased single-limb support were observed after the surgery, indicating a more stable walking balance. These changes lasted for a period of at least 3 months. As a result, shunting surgery may be recommended for geriatric patients with confirmed diagnosis of normal pressure hydrocephalus. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. The Gait Disorder in Downbeat Nystagmus Syndrome

    PubMed Central

    Schniepp, Roman; Wuehr, Max; Huth, Sabrina; Pradhan, Cauchy; Schlick, Cornelia; Brandt, Thomas; Jahn, Klaus

    2014-01-01

    Background Downbeat nystagmus (DBN) is a common form of acquired fixation nystagmus with key symptoms of oscillopsia and gait disturbance. Gait disturbance could be a result of impaired visual feedback due to the involuntary ocular oscillations. Alternatively, a malfunction of cerebellar locomotor control might be involved, since DBN is considered a vestibulocerebellar disorder. Methods Investigation of walking in 50 DBN patients (age 72±11 years, 23 females) and 50 healthy controls (HS) (age 70±11 years, 23 females) using a pressure sensitive carpet (GAITRite). The patient cohort comprised subjects with only ocular motor signs (DBN) and subjects with an additional limb ataxia (DBNCA). Gait investigation comprised different walking speeds and walking with eyes closed. Results In DBN, gait velocity was reduced (p<0.001) with a reduced stride length (p<0.001), increased base of support (p<0.050), and increased double support (p<0.001). Walking with eyes closed led to significant gait changes in both HS and DBN. These changes were more pronounced in DBN patients (p<0.001). Speed-dependency of gait variability revealed significant differences between the subgroups of DBN and DBNCA (p<0.050). Conclusions (I) Impaired visual control caused by involuntary ocular oscillations cannot sufficiently explain the gait disorder. (II) The gait of patients with DBN is impaired in a speed dependent manner. (III) Analysis of gait variability allows distinguishing DBN from DBNCA: Patients with pure DBN show a speed dependency of gait variability similar to that of patients with afferent vestibular deficits. In DBNCA, gait variability resembles the pattern found in cerebellar ataxia. PMID:25140517

  5. Evaluating alternative gait strategies using evolutionary robotics

    PubMed Central

    Sellers, William I; Dennis, Louise A; Wang, W -J; Crompton, Robin H

    2004-01-01

    Evolutionary robotics is a branch of artificial intelligence concerned with the automatic generation of autonomous robots. Usually the form of the robot is predefined and various computational techniques are used to control the machine's behaviour. One aspect is the spontaneous generation of walking in legged robots and this can be used to investigate the mechanical requirements for efficient walking in bipeds. This paper demonstrates a bipedal simulator that spontaneously generates walking and running gaits. The model can be customized to represent a range of hominoid morphologies and used to predict performance parameters such as preferred speed and metabolic energy cost. Because it does not require any motion capture data it is particularly suitable for investigating locomotion in fossil animals. The predictions for modern humans are highly accurate in terms of energy cost for a given speed and thus the values predicted for other bipeds are likely to be good estimates. To illustrate this the cost of transport is calculated for Australopithecus afarensis. The model allows the degree of maximum extension at the knee to be varied causing the model to adopt walking gaits varying from chimpanzee-like to human-like. The energy costs associated with these gait choices can thus be calculated and this information used to evaluate possible locomotor strategies in early hominids. PMID:15198699

  6. Activity-specific aquatic therapy targeting gait for a patient with incomplete spinal cord injury.

    PubMed

    Wall, Tracy; Falvo, Lisa; Kesten, Adam

    2017-04-01

    Aquatic therapy can lead to improved mobility and health in individuals with various conditions. This case report looks at an activity-specific aquatic therapy targeting gait for a patient with incomplete spinal cord injury (iSCI). The patient participated in an individualized aquatic therapy program two times a week for 6 weeks. Assessment occurred prior to the intervention. There were two follow-up assessments after the intervention. Follow-up assessment 1 was completed within the same week as the final intervention. Follow-up assessment 2 was completed 4 weeks after the first follow-up to assess for carryover. Improvements that met minimal detectable change and minimal clinically important difference were noted in The Walking for Spinal Cord Injury Index-II, Spinal Cord Injury Functional Ambulation Index gait parameters, and gait speed. An activity-specific aquatic therapy program improved gait in a patient with iSCI. The properties of water create a practical environment for safe practice of skills. Further studies are warranted in large samples.

  7. Effects of Antigravity Treadmill Training on Gait, Balance, and Fall Risk in Children With Diplegic Cerebral Palsy.

    PubMed

    El-Shamy, Shamekh Mohamed

    2017-11-01

    The aim of this study was to investigate the effects of antigravity treadmill training on gait, balance, and fall risk in children with diplegic cerebral palsy. Thirty children with diplegic cerebral palsy were selected for this randomized controlled study. They were randomly assigned to (1) an experimental group that received antigravity treadmill training (20 mins/d, 3 d/wk) together with traditional physical therapy for 3 successive mos and (2) a control group that received only traditional physical therapy program for the same period. Outcomes included selected gait parameters, postural stability, and fall risk. Outcomes were measured at baseline and after 3 mos of intervention. Children in both groups showed significant improvements in the mean values of all measured variables (P < 0.05), with significantly greater improvements in the experimental group than the control group. The posttreatment gait parameters (i.e., velocity, stride length, cadence, and percent of time spent in double-limb support) were 0.74 m/sec, 119 steps/min, 0.75 m/sec, 0.65 sec, and 55.9% as well as 0.5 m, 125 steps/min, 0.6 m/sec, 0.49 sec, and 50.4% for the experimental and control group, respectively. Antigravity treadmill training may be a useful tool for improving gait parameters, balance, and fall risk in children with diplegic cerebral palsy.

  8. Gait recognition based on integral outline

    NASA Astrophysics Data System (ADS)

    Ming, Guan; Fang, Lv

    2017-02-01

    Biometric identification technology replaces traditional security technology, which has become a trend, and gait recognition also has become a hot spot of research because its feature is difficult to imitate and theft. This paper presents a gait recognition system based on integral outline of human body. The system has three important aspects: the preprocessing of gait image, feature extraction and classification. Finally, using a method of polling to evaluate the performance of the system, and summarizing the problems existing in the gait recognition and the direction of development in the future.

  9. Feasibility Study of a Wearable Exoskeleton for Children: Is the Gait Altered by Adding Masses on Lower Limbs?

    PubMed Central

    Rossi, Stefano; Colazza, Alessandra; Petrarca, Maurizio; Castelli, Enrico; Cappa, Paolo; Krebs, Hermano Igo

    2013-01-01

    We are designing a pediatric exoskeletal ankle robot (pediatric Anklebot) to promote gait habilitation in children with Cerebral Palsy (CP). Few studies have evaluated how much or whether the unilateral loading of a wearable exoskeleton may have the unwanted effect of altering significantly the gait. The purpose of this study was to evaluate whether adding masses up to 2.5 kg, the estimated overall added mass of the mentioned device, at the knee level alters the gait kinematics. Ten healthy children and eight children with CP, with light or mild gait impairment, walked wearing a knee brace with several masses. Gait parameters and lower-limb joint kinematics were analyzed with an optoelectronic system under six conditions: without brace (natural gait) and with masses placed at the knee level (0.5, 1.0, 1.5, 2.0, 2.5 kg). T-tests and repeated measures ANOVA tests were conducted in order to find noteworthy differences among the trial conditions and between loaded and unloaded legs. No statistically significant differences in gait parameters for both healthy children and children with CP were observed in the five “with added mass” conditions. We found significant differences among “natural gait” and “with added masses” conditions in knee flexion and hip extension angles for healthy children and in knee flexion angle for children with CP. This result can be interpreted as an effect of the mechanical constraint induced by the knee brace rather than the effect associated with load increase. The study demonstrates that the mechanical constraint induced by the brace has a measurable effect on the gait of healthy children and children with CP and that the added mass up to 2.5 kg does not alter the lower limb kinematics. This suggests that wearable devices weighing 25 N or less will not noticeably modify the gait patterns of the population examined here. PMID:24023822

  10. Spinal fusion limits upper body range of motion during gait without inducing compensatory mechanisms in adolescent idiopathic scoliosis patients.

    PubMed

    Holewijn, R M; Kingma, I; de Kleuver, M; Schimmel, J J P; Keijsers, N L W

    2017-09-01

    Previous studies show a limited alteration of gait at normal walking speed after spinal fusion surgery for adolescent idiopathic scoliosis (AIS), despite the presumed essential role of spinal mobility during gait. This study analyses how spinal fusion affects gait at more challenging walking speeds. More specifically, we investigated whether thoracic-pelvic rotations are reduced to a larger extent at higher gait speeds and whether compensatory mechanisms above and below the stiffened spine are present. 18 AIS patients underwent gait analysis at increasing walking speeds (0.45 to 2.22m/s) before and after spinal fusion. The range of motion (ROM) of the upper (thorax, thoracic-pelvic and pelvis) and lower body (hip, knee and ankle) was determined in all three planes. Spatiotemporal parameters of interest were stride length and cadence. Spinal fusion diminished transverse plane thoracic-pelvic ROM and this difference was more explicit at higher walking speeds. Transversal pelvis ROM was also decreased but this effect was not affected by speed. Lower body ROM, step length and cadence remained unaffected. Despite the reduction of upper body ROM after spine surgery during high speed gait, no altered spatiotemporal parameters or increased compensatory ROM above or below the fusion (i.e. in the shoulder girdle or lower extremities) was identified. Thus, it remains unclear how patients can cope so well with such major surgery. Future studies should focus on analyzing the kinematics of individual spinal levels above and below the fusion during gait to investigate possible compensatory mechanisms within the spine. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Knee osteoarthritis, degenerative meniscal lesion and osteonecrosis of the knee: Can a simple gait test direct us to a better clinical diagnosis.

    PubMed

    Debi, R; Elbaz, A; Mor, A; Kahn, G; Peskin, B; Beer, Y; Agar, G; Morag, G; Segal, G

    2017-06-01

    The purpose of the current study was to compare the gait patterns in patients with three differing knee pathologies - knee osteoarthritis (OA), degenerative meniscal lesion (DML) and spontaneous osteonecrosis of the knee (SONK) and a group of healthy controls. A simple gait test will detect differences between different knee pathologies. Forty-seven patients with bilateral knee OA, 47 patients with DML, 28 patients with SONK and 27 healthy controls were included in this analysis. Patients underwent a spatiotemporal gait assessment and were asked to complete the Western Ontario and McMaster University (WOMAC) Index and the Short-Form (SF)-36 Health Survey. ANOVA tests, followed by Bonferroni multiple comparison tests and the Chi 2 tests were performed for continuous and categorical variables, respectively. Significant differences were found for all gait measures and clinical questionnaires between healthy controls and all knee conditions. Patients with SONK differed from patients with bilateral knee OA and DML in all gait measures and clinical questionnaires, except for WOMAC subscales. There were no significant differences between patients with bilateral knee OA and patients with DML. Symmetry was also examined and revealed asymmetry in some gait parameters in patients with SONK and DML. Based on the differences in gait parameters that were found in the current study, adding an objective functional spatiotemporal gait test may assist in the diagnostic process of knee pathologies. Case Control study Level III. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Effects of frontal and sagittal thorax attitudes in gait on trunk and pelvis three-dimensional kinematics.

    PubMed

    Begon, Mickaël; Leardini, Alberto; Belvedere, Claudio; Farahpour, Nader; Allard, Paul

    2015-10-01

    While sagittal trunk inclinations alter upper body biomechanics, little is known about the extent of frontal trunk bending on upper body and pelvis kinematics in adults during gait and its relation to sagittal trunk inclinations. The objective was to determine the effect of the mean lateral trunk attitude on upper body and pelvis three-dimensional kinematics during gait in asymptomatic subjects. Three gait cycles were collected in 30 subjects using a motion analysis system (Vicon 612) and an established protocol. Sub-groups were formed based on the mean thorax lateral bending angle, bending side, and also sagittal tilt. These were compared based on 38 peak angles identified on pelvis, thorax and shoulder kinematics using MANOVAs. A main effect for bending side (p = 0.038) was found, especially for thorax peak angles. Statistics revealed also a significant interaction (p = 0.04993) between bending side and tilt for the thorax sagittal inclination during body-weight transfer. These results reinforce the existence of different gait patterns, which correlate upper body and pelvis motion measures. The results also suggest that frontal and sagittal trunk attitude should be considered carefully when treating a patient with impaired gait. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Interaction between thorax, lumbar, and pelvis movements in the transverse plane during gait at three velocities.

    PubMed

    Yang, Ya-Ting; Yoshida, Yasuyuki; Hortobágyi, Tibor; Suzuki, Shuji

    2013-06-01

    We determined the angular range of motion and the relative timing of displacement in the thorax, lumbar spine, and pelvis in the transverse plane during treadmill walking at three velocities. Nine healthy young females walked on a treadmill for three minutes at 0.40, 0.93, and 1.47 m/s. The position of seven reflective markers and three rigs placed on the thorax, lumbar spine, and pelvis were recorded at 200 Hz by an eight-camera motion capture system. As gait velocity increased, stride length increased, cycle time decreased, and angular displacement in the thorax and L1 decreased but increased at the pelvis and L5 (all P < .05). The time of maxi- mal angular rotation occurred in the following sequence: pelvis, L5, L3, L1, and thorax (P < .001). The thorax and L1 and L3 were in-phase for shorter duration as gait velocity increased, and this reduction was especially large, approx. 32% (P < .05), between thorax and pelvis. As gait velocity increased, the pelvis rotated earlier, causing the shortening of in-phase duration between thorax and pelvis. These data suggest that, as gait velocity increases, pelvis rotation dictates trunk rotation in the transverse plane during gait in healthy young females.

  14. Contribution of ankle-foot orthosis moment in regulating ankle and knee motions during gait in individuals post-stroke.

    PubMed

    Kobayashi, Toshiki; Orendurff, Michael S; Singer, Madeline L; Gao, Fan; Foreman, K Bo

    2017-06-01

    Ankle-foot orthosis moment resisting plantarflexion has systematic effects on ankle and knee joint motion in individuals post-stroke. However, it is not known how much ankle-foot orthosis moment is generated to regulate their motion. The aim of this study was to quantify the contribution of an articulated ankle-foot orthosis moment to regulate ankle and knee joint motion during gait in individuals post-stroke. Gait data were collected from 10 individuals post-stroke using a Bertec split-belt instrumented treadmill and a Vicon 3-dimensional motion analysis system. Each participant wore an articulated ankle-foot orthosis whose moment resisting plantarflexion was adjustable at four levels. Ankle-foot orthosis moment while walking was calculated under the four levels based on angle-moment relationship of the ankle-foot orthosis around the ankle joint measured by bench testing. The ankle-foot orthosis moment and the joint angular position (ankle and knee) relationship in a gait cycle was plotted to quantify the ankle-foot orthosis moment needed to regulate the joint motion. Ankle and knee joint motion were regulated according to the amount of ankle-foot orthosis moment during gait. The ankle-foot orthosis maintained the ankle angular position in dorsiflexion and knee angular position in flexion throughout a gait cycle when it generated moment from -0.029 (0.011) to -0.062 (0.019) Nm/kg (moment resisting plantarflexion was defined as negative). Quantifying the contribution of ankle-foot orthosis moment needed to regulate lower limb joints within a specific range of motion could provide valuable criteria to design an ankle-foot orthosis for individuals post-stroke. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Accuracy and reliability of observational gait analysis data: judgments of push-off in gait after stroke.

    PubMed

    McGinley, Jennifer L; Goldie, Patricia A; Greenwood, Kenneth M; Olney, Sandra J

    2003-02-01

    Physical therapists routinely observe gait in clinical practice. The purpose of this study was to determine the accuracy and reliability of observational assessments of push-off in gait after stroke. Eighteen physical therapists and 11 subjects with hemiplegia following a stroke participated in the study. Measurements of ankle power generation were obtained from subjects following stroke using a gait analysis system. Concurrent videotaped gait performances were observed by the physical therapists on 2 occasions. Ankle power generation at push-off was scored as either normal or abnormal using two 11-point rating scales. These observational ratings were correlated with the measurements of peak ankle power generation. A high correlation was obtained between the observational ratings and the measurements of ankle power generation (mean Pearson r=.84). Interobserver reliability was moderately high (mean intraclass correlation coefficient [ICC (2,1)]=.76). Intraobserver reliability also was high, with a mean ICC (2,1) of.89 obtained. Physical therapists were able to make accurate and reliable judgments of push-off in videotaped gait of subjects following stroke using observational assessment. Further research is indicated to explore the accuracy and reliability of data obtained with observational gait analysis as it occurs in clinical practice.

  16. Effect of rhythmic auditory cueing on gait in people with Alzheimer disease.

    PubMed

    Wittwer, Joanne E; Webster, Kate E; Hill, Keith

    2013-04-01

    To determine whether rhythmic music and metronome cues alter spatiotemporal gait measures and gait variability in people with Alzheimer disease (AD). A repeated-measures study requiring participants to walk under different cueing conditions. University movement laboratory. Of the people (N=46) who met study criteria (a diagnosis of probable AD and ability to walk 100m) at routine medical review, 30 (16 men; mean age ± SD, 80±6y; revised Addenbrooke's Cognitive Examination range, 26-79) volunteered to participate. Participants walked 4 times over an electronic walkway synchronizing to (1) rhythmic music and (2) a metronome set at individual mean baseline comfortable speed cadence. Gait spatiotemporal measures and gait variability (coefficient of variation [CV]). Data from individual walks under each condition were combined. A 1-way repeated-measures analysis of variance was used to compare uncued baseline, cued, and retest measures. Gait velocity decreased with both music and metronome cues compared with baseline (baseline, 110.5cm/s; music, 103.4cm/s; metronome, 105.4cm/s), primarily because of significant decreases in stride length (baseline, 120.9cm; music, 112.5cm; metronome, 114.8cm) with both cue types. This was coupled with increased stride length variability compared with baseline (baseline CV, 3.4%; music CV, 4.3%; metronome CV, 4.5%) with both cue types. These changes did not persist at (uncued) retest. Temporal variability was unchanged. Rhythmic auditory cueing at comfortable speed tempo produced deleterious effects on gait in a single session in this group with AD. The deterioration in spatial gait parameters may result from impaired executive function associated with AD. Further research should investigate whether these instantaneous cue effects are altered with more practice or with learning methods tailored to people with cognitive impairment. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights

  17. Assistive devices alter gait patterns in Parkinson disease: advantages of the four-wheeled walker.

    PubMed

    Kegelmeyer, Deb A; Parthasarathy, Sowmya; Kostyk, Sandra K; White, Susan E; Kloos, Anne D

    2013-05-01

    Gait abnormalities are a hallmark of Parkinson's disease (PD) and contribute to fall risk. Therapy and exercise are often encouraged to increase mobility and decrease falls. As disease symptoms progress, assistive devices are often prescribed. There are no guidelines for choosing appropriate ambulatory devices. This unique study systematically examined the impact of a broad range of assistive devices on gait measures during walking in both a straight path and around obstacles in individuals with PD. Quantitative gait measures, including velocity, stride length, percent swing and double support time, and coefficients of variation were assessed in 27 individuals with PD with or without one of six different devices including canes, standard and wheeled walkers (two, four or U-Step). Data were collected using the GAITRite and on a figure-of-eight course. All devices, with the exception of four-wheeled and U-Step walkers significantly decreased gait velocity. The four-wheeled walker resulted in less variability in gait measures and had less impact on spontaneous unassisted gait patterns. The U-Step walker exhibited the highest variability across all parameters followed by the two-wheeled and standard walkers. Higher variability has been correlated with increased falls. Though subjects performed better on a figure-of-eight course using either the four-wheeled or the U-Step walker, the four-wheeled walker resulted in the most consistent improvement in overall gait variables. Laser light use on a U-Step walker did not improve gait measures or safety in figure-of-eight compared to other devices. Of the devices tested, the four-wheeled-walker offered the most consistent advantages for improving mobility and safety. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Control of the motion of the body's center of mass in relation to the center of pressure during high-heeled gait.

    PubMed

    Chien, Hui-Lien; Lu, Tung-Wu; Liu, Ming-Wei

    2013-07-01

    High-heeled shoes are associated with instability and falling, leading to injuries such as fracture and ankle sprain. Knowledge of the motion of the body's center of mass (COM) with respect to the center of pressure (COP) during high-heeled gait may offer insights into the balance control strategies and provide a basis for approaches that minimize the risk of falling and associated adverse effects. The study aimed to investigate the influence of the base and height of the heels on the COM motion in terms of COM-COP inclination angles (IA) and the rate of change of IA (RCIA). Fifteen females who regularly wear high heels walked barefoot and with narrow-heeled shoes with three heel heights (3.9cm, 6.3cm and 7.3cm) while kinematic and ground reaction force data were measured and used to calculate the COM and COP, as well as the temporal-distance parameters. The reduced base of the heels was found to be the primary factor for the reduced normalized walking speed and the reduced frontal IA throughout the gait cycle. This was achieved mainly through the control of the RCIA during double-leg stance (DLS). The heel heights affected mainly the peak RCIA during DLS, which were not big enough to affect the IA. These results suggest young adults adopt a conservative strategy for balance control during narrow-heeled gait. The results will serve as baseline data for future evaluation of patients and/or older adults during narrow-heeled gait with the aim of reducing the risk of falling. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. A Surgical Model of Posttraumatic Osteoarthritis With Histological and Gait Validation.

    PubMed

    Zahoor, Talal; Mitchell, Reed; Bhasin, Priya; Schon, Lew; Zhang, Zijun

    2016-07-01

    Posttraumatic osteoarthritis (PTOA) is secondary to an array of joint injuries. Animal models are useful tools for addressing the uniqueness of PTOA progression in each type of joint injury and developing strategies for PTOA prevention and treatment. Intra-articular fracture induces PTOA pathology. Descriptive laboratory study. Through a parapatellar incision, the medial tibial plateau was exposed in the left knees of 8 Sprague-Dawley rats. Osteotomy at the midpoint between the tibial crest and the outermost portion of the medial tibial plateau, including the covering articular cartilage, was performed using a surgical blade. The fractured medial tibial plateau was fixed with 2 needles transversely. The fractured knees were not immobilized. Before and after surgery, rat gait was recorded. Rats were sacrificed at week 8, and their knees were harvested for histology. After intra-articular fracture, the affected limbs altered gait from baseline (week 0). In the first 2 weeks, the gait of the operated limbs featured a reduced paw print intensity and stride length but increased maximal contact and stance time. Reduction of maximal and mean print area and duty cycle (the percentage of stance phase in a step) was present from week 1 to week 5. Only print length was reduced in weeks 7 and 8. At week 8, histology of the operated knees demonstrated osteoarthritic pathology. The severity of the PTOA pathology did not correlate with the changes of print length at week 8. Intra-articular fracture of the medial tibial plateau effectively induced PTOA in rat knees. During PTOA development, the injured limbs demonstrated characteristic gait. Intra-articular fracture represents severe joint injury and associates with a high rate of PTOA. This animal model, with histologic and gait validations, can be useful for future studies of PTOA prevention and early diagnosis.

  20. Linear variability of gait according to socioeconomic status in elderly

    PubMed Central

    2016-01-01

    Aim: To evaluate the linear variability of comfortable gait according to socioeconomic status in community-dwelling elderly. Method: For this cross-sectional observational study 63 self- functioning elderly were categorized according to the socioeconomic level on medium-low (n= 33, age 69.0 ± 5.0 years) and medium-high (n= 30, age 71.0 ± 6.0 years). Each participant was asked to perform comfortable gait speed for 3 min on an 40 meters elliptical circuit, recording in video five strides which were transformed into frames, determining the minimum foot clearance, maximum foot clearance and stride length. The intra-group linear variability was calculated by the coefficient of variation in percent. Results: The trajectory parameters variability is not different according to socioeconomic status with a 30% (range= 15-55%) for the minimum foot clearance and 6% (range= 3-8%) in maximum foot clearance. Meanwhile, the stride length consistently was more variable in the medium-low socioeconomic status for the overall sample (p= 0.004), female (p= 0.041) and male gender (p= 0.007), with values near 4% ​​(range = 2.5-5.0%) in the medium-low and 2% (range = 1.5-3.5%) in the medium-high. Conclusions: The intra-group linear variability is consistently higher and within reference parameters for stride length during comfortable gait for elderly belonging to medium-low socioeconomic status. This might be indicative of greater complexity and consequent motor adaptability. PMID:27546931