Sample records for galilei dual scheimpflug

  1. Evaluation of corneal pachymetry measurements by Galilei dual Scheimpflug camera.

    PubMed

    Karimian, Farid; Feizi, Sepehr; Faramarzi, Amir; Doozandeh, Azadeh; Yaseri, Mehdi

    2012-01-01

    We present an evaluation of corneal pachymetry measurements by Galilei dual Scheimpflug camera by comparing central corneal thickness measured by Galilei with Orbscan II and ultrasonic pachymetry. Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences and Negah Eye Center, Tehran, Iran. Central corneal thickness (CCT) was measured in 184 eyes of 92 healthy subjects using Galilei, Orbscan II, and ultrasonic (US) pachymetry. Considered as a benchmark, the measurements by US pachymetry were compared with those measured by the other 2 systems. Mean CCT was 544.4 ± 33.4 µm, 546.7 ± 37.9 µm, and 555.8 ± 29.6 µm as measured by US pachymetry, Orbscan II, and Galilei systems, respectively. The mean difference of readings measured by US pachymetry with those measured by Orbscan II (acoustic coefficient 0.96) and Galilei were 2.3 µm and 10.2 µm, respectively. In spite of this discrepancy, the Galilei system had better agreement with US pachymetry than Orbscan II and US pachymetry (correlation coefficient 0.947 vs 0.817) and considering 0.98 as acoustic coefficient for Galilei CCT reading, makes its measurements identical to ultrasound pachymetry. Galilei measurements of CCT are well correlated with ultrasound pachymetry in normal eyes. After considering an acoustic coefficient equal to 0.98 for Galilei, its measurements will become equal to ultrasound values.

  2. Effects of Birth Weight on Anterior Segment Measurements in Full-Term Children Without Low Birth Weight by Dual-Scheimpflug Analyzer.

    PubMed

    Yeter, Volkan; Aritürk, Nurşen; Bİrİncİ, Hakki; Süllü, Yüksel; Güngör, İncİ

    2015-10-01

    To evaluate the effects of birth weight on ocular anterior segment parameters in full-term children without low birth weight using the Galilei Dual-Scheimpflug Analyzer. Retrospective cohort study. The right eyes from 110 healthy children, 3-6 years of age, were scanned with the Galilei Dual-Scheimpflug Analyzer. A total of 78 eyes were measured in full-term children with birth weight of >2500 g. Central, paracentral, pericentral, and the thinnest corneal thicknesses; anterior and posterior keratometry (average, steep, flat); axial curvatures; asphericity of cornea; anterior chamber depth and volume; and iridocorneal angle values were measured. Axial length, lens thickness, and vitreous length were obtained by ultrasound biometry. The mean age of children was 55.86 ± 12.52 (mean ± SD) months. Mean birth weight and gestational age were 3426.3 ± 545 g and 39.4 ± 1.2 weeks, respectively. Although lens thickness, vitreous length, axial length, and anterior chamber volume were moderately correlated with birth weight (P < .05), there was no relationship between birth weight and anterior chamber depth. With the exception of pericentral corneal thickness, all regions of corneal thicknesses were correlated with birth weight (P < .05). Birth weight was negatively correlated with anterior curvature (P < .05) and had no relationship to posterior curvature. While central and paracentral axial curvatures correlated with birth weight (P < .05), pericentral axial curvature did not. Preschoolers who were born heavier had thicker cornea and lens, longer axial length, and flatter corneal curve. The thicknesses and axial curves of central cornea within 7 mm may be particularly associated with birth weight. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Corneal changes with accommodation using dual Scheimpflug photography.

    PubMed

    Sisó-Fuertes, Irene; Domínguez-Vicent, Alberto; del Águila-Carrasco, Antonio; Ferrer-Blasco, Teresa; Montés-Micó, Robert

    2015-05-01

    To assess whether corneal parameters and aberrations are affected by accommodation. Optics Department, University of Valencia, Valencia, Spain. Prospective cross-sectional study. The Galilei G4 dual Scheimpflug device was used to obtain data on the anterior and posterior axial curvatures, total corneal power (TCP), and corneal pachymetry from 3 corneal zones (central: 0.0 up to 4.0 mm; paracentral or mid: 4.0 up to 7.0 mm; peripheral: 7.0 up to 10.0 mm) in young emmetropic eyes in the unaccommodated and 4 accommodated states (from -1.0 to -4.0 diopters [D] in 1.0 D steps). The 2nd-, 3rd-, and 4th-order aberrations as well as the root mean square (RMS) were also determined for the entire cornea at the same accommodative demands. The study evaluated 7 subjects (12 eyes). No significant changes in any measured parameter were found during accommodation for any corneal zone (P > .05). Statistically significant differences were found in the various corneal zones when it was assumed they were constant with accommodation (P < .01). A stable linear trend with accommodation was also found for corneal aberrations, although individual variations existed because of the high standard deviation values. Different parameters in various zones of the cornea as well as corneal aberrations were stable during accommodation. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  4. Quality of vision after excimer laser phototherapeutic keratectomy with intraoperative mitomycin-C for Salzmann nodular degeneration.

    PubMed

    Reddy, Jagadesh C; Rapuano, Christopher J; Felipe, Anthony F; Nagra, Parveen K; Hammersmith, Kristin M

    2014-07-01

    To assess the effect of excimer laser phototherapeutic keratectomy (PTK) with intraoperative mitomycin-C (MMC) on the quality of vision in patients with Salzmann nodular degeneration (SND). Thirteen eyes of 12 patients were enrolled in the study between December 2010 and March 2012. Uncorrected and best-corrected Snellen distance visual acuities were measured at every visit. Contrast sensitivity and manifest refraction were measured preoperatively, at 1 month and at 3 months. Corneal topography, Galilei dual Scheimpflug imaging, VISX WaveScan, and ultrasound central corneal pachymetry were measured preoperatively and at 3 months after PTK procedure. Contrast sensitivity was statistically significantly better both at 1 month (P<0.01) and 3 months (P<0.01). Postoperatively, there was 46% increase in eyes with measurable corneal topography, 69% increase in Galilei dual Scheimpflug imaging, and a 77% increase in WaveScan measurements. The third-order (P<0.01) and total corneal higher-order aberrations (HOAs) (P=0.01) were significantly lower postoperatively compared with the preoperative corneal aberrations measured on Galilei dual Scheimpflug imaging. Significant improvement in contrast sensitivity and corneal HOAs was seen after PTK for SND. Phototherapeutic keratectomy with MMC can be considered as an effective procedure in the improvement of the quality of vision in patients with SND.

  5. Comparison of corneal power, astigmatism, and wavefront aberration measurements obtained by a point-source color light-emitting diode-based topographer, a Placido-disk topographer, and a combined Placido and dual Scheimpflug device.

    PubMed

    Ventura, Bruna V; Wang, Li; Ali, Shazia F; Koch, Douglas D; Weikert, Mitchell P

    2015-08-01

    To evaluate and compare the performance of a point-source color light-emitting diode (LED)-based topographer (color-LED) in measuring anterior corneal power and aberrations with that of a Placido-disk topographer and a combined Placido and dual Scheimpflug device. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas USA. Retrospective observational case series. Normal eyes and post-refractive-surgery eyes were consecutively measured using color-LED, Placido, and dual-Scheimpflug devices. The main outcome measures were anterior corneal power, astigmatism, and higher-order aberrations (HOAs) (6.0 mm pupil), which were compared using the t test. There were no statistically significant differences in corneal power measurements in normal and post-refractive surgery eyes and in astigmatism magnitude in post-refractive surgery eyes between the color-LED device and Placido or dual Scheimpflug devices (all P > .05). In normal eyes, there were no statistically significant differences in 3rd-order coma and 4th-order spherical aberration between the color-LED and Placido devices and in HOA root mean square, 3rd-order coma, 3rd-order trefoil, 4th-order spherical aberration, and 4th-order secondary astigmatism between the color-LED and dual Scheimpflug devices (all P > .05). In post-refractive surgery eyes, the color-LED device agreed with the Placido and dual-Scheimpflug devices regarding 3rd-order coma and 4th-order spherical aberration (all P > .05). In normal and post-refractive surgery eyes, all 3 devices were comparable with respect to corneal power. The agreement in corneal aberrations varied. Drs. Wang, Koch, and Weikert are consultants to Ziemer Ophthalmic Systems AG. Dr. Koch is a consultant to Abbott Medical Optics, Inc., Alcon Surgical, Inc., and i-Optics Corp. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Agreement between total corneal astigmatism calculated by vector summation and total corneal astigmatism measured by ray tracing using Galilei double Scheimpflug analyzer.

    PubMed

    Feizi, Sepehr; Delfazayebaher, Siamak; Ownagh, Vahid; Sadeghpour, Fatemeh

    To evaluate the agreement between total corneal astigmatism calculated by vector summation of anterior and posterior corneal astigmatism (TCA Vec ) and total corneal astigmatism measured by ray tracing (TCA Ray ). This study enrolled a total of 204 right eyes of 204 normal subjects. The eyes were measured using a Galilei double Scheimpflug analyzer. The measured parameters included simulated keratometric astigmatism using the keratometric index, anterior corneal astigmatism using the corneal refractive index, posterior corneal astigmatism, and TCA Ray . TCA Vec was derived by vector summation of the astigmatism on the anterior and posterior corneal surfaces. The magnitudes and axes of TCA Vec and TCA Ray were compared. The Pearson correlation coefficient and Bland-Altman plots were used to assess the relationship and agreement between TCA Vec and TCA Ray , respectively. The mean TCA Vec and TCA Ray magnitudes were 0.76±0.57D and 1.00±0.78D, respectively (P<0.001). The mean axis orientations were 85.12±30.26° and 89.67±36.76°, respectively (P=0.02). Strong correlations were found between the TCA Vec and TCA Ray magnitudes (r=0.96, P<0.001). Moderate associations were observed between the TCA Vec and TCA Ray axes (r=0.75, P<0.001). Bland-Altman plots produced the 95% limits of agreement for the TCA Vec and TCA Ray magnitudes from -0.33 to 0.82D. The 95% limits of agreement between the TCA Vec and TCA Ray axes was -43.0 to 52.1°. The magnitudes and axes of astigmatisms measured by the vector summation and ray tracing methods cannot be used interchangeably. There was a systematic error between the TCA Vec and TCA Ray magnitudes. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  7. Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography.

    PubMed

    Jung, Soyeon; Chin, Hee Seung; Kim, Na Rae; Lee, Kang Won; Jung, Ji Won

    2017-01-01

    To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT ( P > 0.050), although flattest K, mean K, and CCT differed ( P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.

  8. Effect of post crosslinking haze on the repeatability of Scheimpflug-based and slit-scanning imaging devices

    PubMed Central

    Shetty, Rohit; Agrawal, Aarti; Deshmukh, Rashmi; Kaweri, Luci; Rao, Harsha L; Nagaraja, Harsha; Jayadev, Chaitra

    2017-01-01

    Purpose: The aim of this study was to analyze the effect of postcollagen crosslinking (CXL) haze on the measurement and repeatability of pachymetry and mean keratometry (Km) of four corneal topographers. Materials and Methods: Sixty eyes of sixty patients with progressive keratoconus who had undergone accelerated CXL (ACXL) underwent imaging with a scanning slit imaging device (Orbscan II) and three Scheimpflug imaging devices (Pentacam HR, Sirius, and Galilei). Post-ACXL haze was measured using the densitometry software on the Pentacam HR. Readings of the thinnest corneal thickness (TCT) and Km from three scans of each device were analyzed. Effect of haze on the repeatability of TCT and Km measurements was evaluated using regression models. Repeatability was assessed by coefficient of variation. Results: Corneal densitometry in different zones affected the repeatability of TCT measurement of Orbscan (P < 0.05) significantly but not the repeatability of TCT with Pentacam HR and Sirius (P = 0.03 and 0.05, respectively). Km values were affected by haze when measured with the Pentacam HR (P < 0.05). The repeatability of Km readings for all devices was unaffected by haze. In the anterior 0–2 mm and 2–6 mm zone, TCT (P = 0.43 and 0.45, respectively), Km values (P = 0.4 and 0.6, respectively), repeatability of TCT (P = 0.1 in both zones), and Km (P = 0.5 and 0.1, respectively) with Galilei were found to be the most reliable. Conclusion: Galilei measurements appear to be least affected by post-ACXL haze when compared with other devices. Hence, topography measurements in the presence of haze need to be interpreted with caution. PMID:28513495

  9. Scheimpflug imaging in anterior megalophthalmos.

    PubMed

    Nemeth, Gabor; Hassan, Ziad; Berta, Andras; Modis, Laszlo

    2013-01-01

    We report an anterior megalophthalmos case with decreased corneal thickness and show the findings using Scheimpflug imaging. A 25-year-old male was diagnosed with anterior megalophthalmos. In both eyes, enlarged corneal length was measured. Beside a comparatively good visual acuity, a thin but clear cornea, a fairly deep anterior chamber, and central lens opacity were found. Scheimpflug images were taken using Pentacam HR. Scheimpflug-based imaging can provide us new data at the examination of this syndrome affecting the whole anterior segment.

  10. Scheimpflug imaging in anterior megalophthalmos

    PubMed Central

    Nemeth, Gabor; Hassan, Ziad; Berta, Andras; Modis, Laszlo

    2013-01-01

    We report an anterior megalophthalmos case with decreased corneal thickness and show the findings using Scheimpflug imaging. A 25-year-old male was diagnosed with anterior megalophthalmos. In both eyes, enlarged corneal length was measured. Beside a comparatively good visual acuity, a thin but clear cornea, a fairly deep anterior chamber, and central lens opacity were found. Scheimpflug images were taken using Pentacam HR. Scheimpflug-based imaging can provide us new data at the examination of this syndrome affecting the whole anterior segment. PMID:23275220

  11. [Scheimpflug photography for the examination of phakic intraocular lenses].

    PubMed

    Baumeister, M

    2014-10-01

    High myopia phakic intraocular lenses (IOL) have become an established means of surgical correction for high ametropia. Scheimpflug photography is one of the methods which are frequently applied for postoperative examination of the implants. Results from published studies employing Scheimpflug photography for examination of anterior chamber angle-fixated, iris-fixated and sulcus-fixated phakic IOLs were evaluated. In several published studies Scheimpflug photography was used to examine the position of the implant and opacification of the crystalline lens. The results provided valuable evidence for the improvement of phakic IOL design. Scheimpflug photography offers an easy to use, rapid non-contact examination of phakic IOLs.

  12. The Scheimpflug lidar method

    NASA Astrophysics Data System (ADS)

    Brydegaard, Mikkel; Malmqvist, Elin; Jansson, Samuel; Larsson, Jim; Török, Sandra; Zhao, Guangyu

    2017-08-01

    The recent several years we developed the Scheimpflug lidar method. We combined an invention from the 19th century with modern optoelectronics such as diode lasers and CMOS array from the 21st century. The approach exceeds expectations of background suppression, sensitivity and resolution beyond known from time-of-flight lidars. We accomplished multiband elastic atmospheric lidars for resolving single particles and aerosol plumes from 405 nm to 1550 nm. We pursued hyperspectral differential absorption lidar for molecular species. We demonstrated a simple method of inelastic hyperspectral lidar for profiling aquatic environments and vegetation structure. Not least, we have developed polarimetric Scheimpflug lidar with multi-kHz sampling rates for remote modulation spectroscopy and classification of aerofauna. All these advances are thanks to the Scheimpflug principle. Here we give a review of how far we have come and shed light on the limitations and opportunities for future directions. In particular, we show how the biosphere can be resolved with unsurpassed resolution in space and time, and share our expectation on how this can revolutionize ecological analysis and management in relation to agricultural pests, disease vectors and pollinator problematics.

  13. Imaging late capsular block syndrome: ultrasound biomicroscopy versus Scheimpflug camera.

    PubMed

    Kucukevcilioglu, Murat; Hurmeric, Volkan; Erdurman, Fazıl Cuneyt; Ceylan, Osman Melih

    2011-11-01

    We describe 2 patients with late capsular block syndrome whose anterior chamber morphology was evaluated with ultrasound biomicroscopy and Scheimpflug imaging before and after neodymium:YAG laser capsulotomy. Pretreatment ultrasound biomicroscopy examination showed significant capsular bag distension in both patients. Scheimpflug imaging failed to capture the posterior capsule displaced far behind the intraocular lens. Automatic anterior chamber depth measurements were incorrect with Scheimpflug imaging in 1 patient. Ultrasound biomicroscopy seems to be superior to Scheimpflug imaging in eyes with extremely distended capsular bags. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Atmospheric aerosol measurements by employing a polarization scheimpflug lidar system

    NASA Astrophysics Data System (ADS)

    Mei, Liang; Guan, Peng; Yang, Yang

    2018-04-01

    A polarization Scheimpflug lidar system based on the Scheimpflug principle has been developed by employing a compact 808-nm multimode highpower laser diode and two highly integrated CMOS sensors in Dalian University of Technology (DLUT), Dalian, China. The parallel and orthogonal polarized backscattering signal are recorded by two 45 degree tilted image sensors, respectively. Atmospheric particle measurements were carried out by employing the polarization Scheimpflug lidar system.

  15. A Scanning scheimpflug lidar system developed for urban pollution monitoring

    NASA Astrophysics Data System (ADS)

    Yang, Yang; Guan, Peng; Mei, Liang

    2018-04-01

    A scanning Scheimpflug lidar system based on the Scheimpflug principle has been developed by employing a high power multimode 808 nm laser diode and a highly integrated CMOS sensor in Dalian University of Technology, Dalian, Northern China. Atmospheric scanning measurements in urban area were performed for the studies of particle emission sources.

  16. Use of Scheimpflug imaging in the management of intra-lenticular foreign body.

    PubMed

    Singh, R; Ram, J; Gupta, R

    2015-01-01

    Asymptomatic traumatic intra-lenticular foreign body is very uncommon and few case reports have been published. To report a case of post-traumatic intra-lenticular foreign body and use of Scheimpflug imaging in its management. A 41-year-old male with history of injury to right eye during hammering a chisel 1 year back presented with decreased vision since 6 months. An intra-lenticular foreign body was found on slit lamp bio-microscopy and was confrmed by Scheimpflug imaging. Posterior capsule was intact on Scheimpflug imaging. Thus, Scheimpflug imaging helps in exact localization of the foreign body in the intralenticular space or behind the iris. We ruled out other foreign bodies by x-ray and ultrasonography of the orbit. The foreign body with post-traumatic cataract was removed using phacoemulsification and three piece foldable intraocular lens was implanted in the bag. An intra- lenticular foreign body may remain asymptomatic for months. Scheimpflug imaging can be useful in its localization. It can be removed during phacoemulsification. © NEPjOPH.

  17. Comparison of central corneal thickness measurement using ultrasonic pachymetry, rotating Scheimpflug camera, and scanning-slit topography.

    PubMed

    Sedaghat, Mohammad Reza; Daneshvar, Ramin; Kargozar, Abbas; Derakhshan, Akbar; Daraei, Mona

    2010-12-01

    To evaluate and compare central corneal thickness measurements using rotating Scheimpflug camera, scanning-slit topography, and ultrasound pachymetry in virgin, healthy corneas. Prospective, observational, cross-sectional study. Central corneal thickness in 157 healthy eyes of 157 patients without ocular abnormalities other than refractive errors was measured, in a sequential order, once with rotating Scheimpflug camera and scanning-slit topography and 3 times with ultrasound pachymetry as the last part of examination. All measurements were performed by a single experienced examiner. The results from scanning-slit topography are given with and without correction for "acoustic correction factor" of 0.92. The average measurements of central corneal thickness by rotating Scheimpflug imaging, scanning-slit pachymetry, and ultrasound were 537.15 ± 32.98 μm, 542.06 ± 39.04 μm, and 544.07 ± 34.75 μm, respectively. The mean differences between modalities were 6.92 μm between rotating Scheimpflug and ultrasound (P < .0001), 2.01 μm between corrected scanning-slit and ultrasound (P = .204), and 4.91 μm between corrected scanning-slit and rotating Scheimpflug imaging (P = .001). According to Bland-Altman analysis, highest agreement was between ultrasonic and rotating Scheimpflug pachymetry. In the assessment of normal corneas, rotating Scheimpflug topography measures central corneal thickness values with higher agreement to ultrasound pachymetry. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Comparison of Central Corneal Thickness Between Fourier-Domain OCT, Very High-Frequency Digital Ultrasound, and Scheimpflug Imaging Systems.

    PubMed

    Yap, Timothy E; Archer, Timothy J; Gobbe, Marine; Reinstein, Dan Z

    2016-02-01

    To compare corneal thickness measurements between three imaging systems. In this retrospective study of 81 virgin and 58 post-laser refractive surgery corneas, central and minimum corneal thickness were measured using optical coherence tomography (OCT), very high-frequency digital ultrasound (VHF digital ultrasound), and a Scheimpflug imaging system. Agreement between methods was analyzed using mean differences (bias) (OCT - VHF digital ultrasound, OCT - Scheimpflug, VHF digital ultrasound - Scheimpflug) and Bland-Altman analysis with 95% limits of agreement (LoA). Virgin cornea mean central corneal thickness was 508.3 ± 33.2 µm (range: 434 to 588 µm) for OCT, 512.7 ± 32.2 µm (range: 440 to 587 µm) for VHF digital ultrasound, and 530.2 ± 32.6 µm (range: 463 to 612 µm) for Scheimpflug imaging. OCT and VHF digital ultrasound showed the closest agreement with a bias of -4.37 µm, 95% LoA ±12.6 µm. Least agreement was between OCT and Scheimpflug imaging with a bias of -21.9 µm, 95% LoA ±20.7 µm. Bias between VHF digital ultrasound and Scheimpflug imaging was -17.5 µm, 95% LoA ±19.0 µm. In post-laser refractive surgery corneas, mean central corneal thickness was 417.9 ± 47.1 µm (range: 342 to 557 µm) for OCT, 426.3 ± 47.1 µm (range: 363 to 563 µm) for VHF digital ultrasound, and 437.0 ± 48.5 µm (range: 359 to 571 µm) for Scheimpflug imaging. Closest agreement was between OCT and VHF digital ultrasound with a bias of -8.45 µm, 95% LoA ±13.2 µm. Least agreement was between OCT and Scheimpflug imaging with a bias of -19.2 µm, 95% LoA ±19.2 µm. Bias between VHF digital ultrasound and Scheimpflug imaging was -10.7 µm, 95% LoA ±20.0 µm. No relationship was observed between difference in central corneal thickness measurements and mean central corneal thickness. Results were similar for minimum corneal thickness. Central and minimum corneal thickness was measured thinnest by OCT and thickest by Scheimpflug imaging in both groups. A clinically

  19. Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.

    PubMed

    Rosales, Patricia; Marcos, Susana

    2009-05-01

    To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.

  20. Area densitometry using rotating Scheimpflug photography for posterior capsule opacification and surface light scattering analyses.

    PubMed

    Minami, Keiichiro; Honbo, Masato; Mori, Yosai; Kataoka, Yasushi; Miyata, Kazunori

    2015-11-01

    To compare area densitometry analysis using rotating Scheimpflug photography in quantifications of posterior capsule opacification (PCO) and surface light scattering with previous anterior-segment analyzer measurement. Miyata Eye Hospital, Miyazaki, Japan. Prospective observational case series. Scheimpflug images of eyes with foldable intraocular lenses (IOLs) were obtained using rotating and fixed Scheimpflug photography. Area densitometry on the posterior and anterior surfaces was conducted for PCO and surface light scattering analyses, respectively, with an identical area size. Correlation between two measurements was analyzed using linear regression. The study included 105 eyes of 74 patients who received IOLs 1 to 18 years (mean, 4.9 ± 4.5 years) postoperatively. In the PCO analysis on the posterior IOL surface, there was a significant correlation between the two measurements (P < .001, R(2) = 0.60). In the surface light scattering analysis, a significant and higher correlation was obtained (P < .001, R(2) = 0.91) until the fixed Scheimpflug photography exhibited saturation due to intensive scatterings. Area densitometry combined with a rotating Scheimpflug photography was exchangeable to previously established densitometry measurement, and allowed successive evaluation in longer-term observations. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Sunspot Positions and Areas from Observations by Galileo Galilei

    NASA Astrophysics Data System (ADS)

    Vokhmyanin, M. V.; Zolotova, N. V.

    2018-02-01

    Sunspot records in the seventeenth century provide important information on the solar activity before the Maunder minimum, yielding reliable sunspot indices and the solar butterfly diagram. Galilei's letters to Cardinal Francesco Barberini and Marcus Welser contain daily solar observations on 3 - 11 May, 2 June - 8 July, and 19 - 21 August 1612. These historical archives do not provide the time of observation, which results in uncertainty in the sunspot coordinates. To obtain them, we present a method that minimizes the discrepancy between the sunspot latitudes. We provide areas and heliographic coordinates of 82 sunspot groups. In contrast to Sheiner's butterfly diagram, we found only one sunspot group near the Equator. This provides a higher reliability of Galilei's drawings. Large sunspot groups are found to emerge at the same longitude in the northern hemisphere from 3 May to 21 August, which indicates an active longitude.

  2. Atmospheric aerosol and gas sensing using Scheimpflug lidar

    NASA Astrophysics Data System (ADS)

    Mei, Liang; Brydegaard, Mikkel

    2015-04-01

    This work presents a new lidar technique for atmospheric remote sensing based on Scheimpflug principle, which describes the relationship between nonparallel image- and object-planes[1]. When a laser beam is transmitted into the atmosphere, the implication is that the backscattering echo of the entire illuminated probe volume can be in focus simultaneously without diminishing the aperture. The range-resolved backscattering echo can be retrieved by using a tilted line scan or two-dimensional CCD/CMOS camera. Rather than employing nanosecond-pulsed lasers, cascade detectors, and MHz signal sampling, all of high cost and complexity, we have developed a robust and inexpensive atmospheric lidar system based on compact laser diodes and array detectors. We present initial applications of the Scheimpflug lidar for atmospheric aerosol monitoring in bright sunlight, with a 3 W, 808 nm CW laser diode. Kilohertz sampling rates are also achieved with applications for wind speed and entomology [2]. Further, a proof-of-principle demonstration of differential absorption lidar (DIAL) based on the Scheimpflug lidar technique is presented [3]. By utilizing a 30 mW narrow band CW laser diode emitting at around 760 nm, the detailed shape of an oxygen absorption line can be resolved remotely with an integration time of 6 s and measurement cycle of 1 minute during night time. The promising results demonstrated in this work show potential for the Scheimpflug lidar technique for remote atmospheric aerosol and gas sensing, and renews hope for robust and realistic instrumentation for atmospheric lidar sensing. [1] F. Blais, "Review of 20 years of range sensor development," Journal of Electronic Imaging, vol. 13, pp. 231-243, Jan 2004. [2] M. Brydegaard, A. Gebru, and S. Svanberg, "Super resolution laser radar with blinking atmospheric particles - application to interacting flying insects " Progress In Electromagnetics Research, vol. 147, pp. 141-151, 2014. [3] L. Mei and M. Brydegaard

  3. Reconstruction of Galileo Galilei's Experiment: The Inclined Plane

    ERIC Educational Resources Information Center

    Straulino, S.

    2008-01-01

    In the "Third Day" of the "Discourses and Mathematical Demonstrations Concerning Two New Sciences" Galileo Galilei describes the famous experiment of the inclined plane and uses it to bring an experimental confirmation to the laws of uniformly accelerated motion. We describe a reconstruction of the experiment and how the results can be used for…

  4. Conformal Galilei algebras, symmetric polynomials and singular vectors

    NASA Astrophysics Data System (ADS)

    Křižka, Libor; Somberg, Petr

    2018-01-01

    We classify and explicitly describe homomorphisms of Verma modules for conformal Galilei algebras cga_ℓ (d,C) with d=1 for any integer value ℓ \\in N. The homomorphisms are uniquely determined by singular vectors as solutions of certain differential operators of flag type and identified with specific polynomials arising as coefficients in the expansion of a parametric family of symmetric polynomials into power sum symmetric polynomials.

  5. Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.

    PubMed

    de Castro, Alberto; Rosales, Patricia; Marcos, Susana

    2007-03-01

    To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. Measurements of IOL tilt and decentration were obtained using a commercial Scheimpflug system (Pentacam, Oculus), custom algorithms, and a custom-built Purkinje imaging apparatus. Twenty-five Scheimpflug images of the anterior segment of the eye were obtained at different meridians. Custom algorithms were used to process the images (correction of geometrical distortion, edge detection, and curve fittings). Intraocular lens tilt and decentration were estimated by fitting sinusoidal functions to the projections of the pupillary axis and IOL axis in each image. The Purkinje imaging system captures pupil images showing reflections of light from the anterior corneal surface and anterior and posterior lens surfaces. Custom algorithms were used to detect the Purkinje image locations and estimate IOL tilt and decentration based on a linear system equation and computer eye models with individual biometry. Both methods were validated with a physical model eye in which IOL tilt and decentration can be set nominally. Twenty-one eyes of 12 patients with IOLs were measured with both systems. Measurements of the physical model eye showed an absolute discrepancy between nominal and measured values of 0.279 degree (Purkinje) and 0.243 degree (Scheimpflug) for tilt and 0.094 mm (Purkinje) and 0.228 mm (Scheimpflug) for decentration. In patients, the mean tilt was less than 2.6 degrees and the mean decentration less than 0.4 mm. Both techniques showed mirror symmetry between right eyes and left eyes for tilt around the vertical axis and for decentration in the horizontal axis. Both systems showed high reproducibility. Validation experiments on physical model eyes showed slightly higher accuracy

  6. Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik

    PubMed Central

    Chan, Tommy C.Y.; Biswas, Sayantan; Yu, Marco; Jhanji, Vishal

    2015-01-01

    Abstract Swept-source optical coherence tomography (OCT) is the latest advancement in anterior segment imaging. There are limited data regarding its performance after laser in situ keratomileusis (LASIK). We compared the reliability of swept-source OCT and Scheimpflug imaging for evaluation of corneal parameters in refractive surgery candidates with myopia or myopic astigmatism. Three consecutive measurements were obtained preoperatively and 1 year postoperatively using swept-source OCT and Scheimpflug imaging. The study parameters included central corneal thickness (CCT), thinnest corneal thickness (TCT), keratometry at steep (Ks) and flat (Kf) axes, mean keratometry (Km), and, anterior and posterior best fit spheres (Ant and Post BFS). The main outcome measures included reliability of measurements before and after LASIK was evaluated using intraclass correlation coefficient (ICC) and reproducibility coefficients (RC). Association between the mean value of corneal parameters with age, spherical equivalent (SEQ), and residual bed thickness (RBT) and association of variance heterogeneity of corneal parameters and these covariates were analyzed. Twenty-six right eyes of 26 participants (mean age, 32.7 ± 6.9 yrs; mean SEQ, −6.27 ± 1.67 D) were included. Preoperatively, swept-source OCT demonstrated significantly higher ICC for Ks, CCT, TCT, and Post BFS (P ≤ 0.016), compared with Scheimpflug imaging. Swept-source OCT demonstrated significantly smaller RC values for CCT, TCT, and Post BFS (P ≤ 0.001). After LASIK, both devices had significant differences in measurements for all corneal parameters (P ≤ 0.015). Swept-source OCT demonstrated a significantly higher ICC and smaller RC for all measurements, compared with Scheimpflug imaging (P ≤ 0.001). Association of variance heterogeneity was only found in pre-LASIK Ant BFS and post-LASIK Post BFS for swept-source OCT, whereas significant association of variance heterogeneity was noted

  7. Galileo Galilei's vision of the senses.

    PubMed

    Piccolino, Marco; Wade, Nicholas J

    2008-11-01

    Neuroscientists have become increasingly aware of the complexities and subtleties of sensory processing. This applies particularly to the complex elaborations of nerve signals that occur in the sensory circuits, sometimes at the very initial stages of sensory pathways. Sensory processing is now known to be very different from a simple neural copy of the physical signal present in the external world, and this accounts for the intricacy of neural organization that puzzled great investigators of neuroanatomy such as Santiago Ramón Y Cajal a century ago. It will surprise present-day sensory neuroscientists, applying their many modern methods, that the conceptual basis of the contemporary approach to sensory function had been recognized four centuries ago by Galileo Galilei.

  8. Comparing Change in Anterior Curvature after Corneal Cross-Linking Using Scanning-Slit and Scheimpflug Technology.

    PubMed

    Lang, Paul Z; Thulasi, Praneetha; Khandelwal, Sumitra S; Hafezi, Farhad; Randleman, J Bradley

    2018-05-02

    To evaluate the correlation between anterior axial curvature difference maps following corneal cross-linking (CXL) for progressive keratoconus obtained from Scheimpflug-based tomography and Placido-based topography. Between-devices reliability analysis of randomized clinical trial data METHODS: Corneal imaging was collected at a single center institution pre-operatively and at 3, 6, and 12 months post-operatively using Scheimpflug-based tomography (Pentacam, Oculus Inc., Lynnwood, WA) and Scanning-slit, Placido-based topography (Orbscan II, Bausch & Lomb, Rochester, NY) in patients with progressive keratoconus receiving standard protocol CXL (3mW/cm 2 for 30 minutes). Regularization index (RI), absolute maximum keratometry (K Max), and change in (ΔK Max) were compared between the two devices at each time point. 51 eyes from 36 patients were evaluated at all time points. values were significantly different at all time points [56.01±5.3D Scheimpflug vs. 55.04±5.1D scanning-slit pre-operatively (p=0.003); 54.58±5.3D Scheimpflug vs. 53.12±4.9D scanning-slit at 12 months (p<0.0001)] but strongly correlated between devices (r=0.90-0.93) at all time points. The devices were not significantly different at any time point for either ΔK Max or RI but were poorly correlated at all time points (r=0.41-0.53 for ΔK Max, r=0.29-0.48 for RI). At 12 months, 95% LOA was 7.51D for absolute, 8.61D for ΔK Max, and 19.86D for RI. Measurements using Scheimpflug and scanning-slit Placido-based technology are correlated but not interchangeable. Both devices appear reasonable for separately monitoring the cornea's response to CXL; however, caution should be used when comparing results obtained with one measuring technology to the other. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Functional spasm of accommodation: Changes on scheimpflug imaging

    PubMed Central

    Sukhija, Jaspreet; Dogra, Mangat R.; Zadeng, Thara; Ram, Jagat

    2014-01-01

    Spasm of accommodation is a rare condition characterized by a sudden increase in myopia. It can occur in emmetropes, hypermetropes and myopes. All the physiological changes that occur in normal accommodation are exaggerated. Mostly the cause is functional disorder and the condition gradually improves. We hereby present the changes occurring in spasm of accommodation as seen on Scheimpflug imaging. PMID:25378883

  10. Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconus.

    PubMed

    Szalai, Eszter; Berta, András; Hassan, Ziad; Módis, László

    2012-03-01

    To evaluate the repeatability and reliability of a recently introduced swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) system and a high-resolution Scheimpflug camera and to assess the agreement between the 2 instruments when measuring healthy eyes and eyes with keratoconus. Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary. Evaluation of diagnostic test or technology. Three consecutive series of anterior segment images were taken with AS-OCT (Casia SS-1000) followed by rotating Scheimpflug imaging (Pentacam high resolution). Axial keratometry in the steep and flat meridians and astigmatism values were recorded. Pachymetry in the apex, center, and the thinnest position and anterior chamber depth (ACD) measurements were also taken. This study enrolled 57 healthy volunteers (57 eyes) and 56 patients (84 eyes) with keratoconus. Significant difference was found in all measured anterior segment parameters between normal eyes and keratoconic eyes (P<.05). In keratoconic eyes, the difference between repeated measurements was less with AS-OCT than with Scheimpflug imaging in every keratometry and astigmatism value, in apical thickness, and in ACD. For keratometry, the thinnest and central pachymetry measurement repeatability was better in healthy eyes than in keratoconic eyes with both instruments. In general, the mean difference between AS-OCT and Scheimpflug imaging was higher in cases of keratoconus. Significant differences in keratometry, pachymetry, and ACD results were found between AS-OCT and Scheimpflug imaging. However, the repeatability of the measurements was comparable. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. [Evaluation of corneal biomechanics in keratoconus using dynamic ultra-high-speed Scheimpflug measurements].

    PubMed

    Brettl, S; Franko Zeitz, P; Fuchsluger, T A

    2018-06-22

    The in vivo analysis of corneal biomechanics in patients with keratoconus is especially of interest with respect to diagnosis, follow-up and monitoring of the disease. For a better understanding it is necessary to describe the potential of dynamic Scheimpflug measurements for the detection and interpretation of biomechanical changes in keratoconus. The current state of analyzing biomechanical changes in keratoconus with the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) is described. This technique represents a new approach for understanding corneal biomechanics. Furthermore, it was investigated whether the device can biomechanically quantify a rigidity increasing effect of therapeutic UV-crosslinking and whether early stages of keratoconus can be detected using dynamic Scheimpflug analysis. In patients with keratoconus, the in vivo analysis of corneal biomechanics using dynamic Scheimpflug measurements as a supplementary procedure can be of advantage with respect to disease management. By optimization of screening of subclinical keratoconus stages, this method widens the analytic spectrum regarding diagnosis and follow-up of the disease; however, further studies are required to evaluate whether visual outcome of affected patients can be improved by earlier diagnosis.

  12. Effect of Cycloplegia on Corneal Biometrics and Refractive State

    PubMed Central

    Bagheri, Abbas; Feizi, Mohadeseh; Shafii, Aliakbar; Faramarzi, Amir; Tavakoli, Mehdi; Yazdani, Shahin

    2018-01-01

    Purpose: To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. Methods: In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Results: Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia (P < 0.001). The astigmatism power did not significantly change (P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant (P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions (P < 0.001 and P < 0.001, respectively). Conclusion: Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries. PMID:29719636

  13. Effect of Cycloplegia on Corneal Biometrics and Refractive State.

    PubMed

    Bagheri, Abbas; Feizi, Mohadeseh; Shafii, Aliakbar; Faramarzi, Amir; Tavakoli, Mehdi; Yazdani, Shahin

    2018-01-01

    To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia ( P < 0.001). The astigmatism power did not significantly change ( P = 0.8), however, 26.8% of eyes with significant astigmatism experienced a change of more than 5 degrees in the axis of astigmatism. Changes in posterior corneal curvature were scant but statistically significant ( P = 0.001). Moreover, corneal thickness was slightly increased in the central and paracentral regions ( P < 0.001 and P < 0.001, respectively). Cycloplegia causes a hyperopic shift and astigmatism axis changes, along with an increase in central and paracentral corneal thickness and change in posterior corneal curvature. The effects of cycloplegia on refraction and corneal biometrics should be considered before cataract and refractive surgeries.

  14. Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device

    PubMed Central

    Modis, Laszlo; Hassan, Ziad; Szalai, Eszter; Flaskó, Zsuzsanna; Berta, Andras; Nemeth, Gabor

    2016-01-01

    AIM To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83±20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43±21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41±40.17mo (range: 11-128mo) after the keratoplasty and after 7.64±2.34mo (range: 5-14mo) of suture removal. RESULTS Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P<0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects (P=0.003) using the CorVis ST device. The IOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty. PMID:26949641

  15. Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography.

    PubMed

    Amano, Shiro; Honda, Norihiko; Amano, Yuki; Yamagami, Satoru; Miyai, Takashi; Samejima, Tomokazu; Ogata, Miyuki; Miyata, Kazunori

    2006-06-01

    To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. Experimental study. Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. Corneal thickness measurements were compared among the 3 methods in 54 eyes of 54 subjects. Two sets of measurements were repeated by a single examiner for each pachymetry in another 10 eyes of 5 subjects, and the intraexaminer repeatability was assessed as the absolute difference of the first and second measurements. Two experienced examiners took one measurement for each pachymetry in another 10 eyes of 5 subjects, and the interexaminer reproducibility was assessed as the absolute difference of the 2 measurements of the first and second examiners. Central corneal thickness measurements by the 3 methods, absolute difference of the first and second measurements by a single examiner, absolute difference of the 2 measurements by 2 examiners, and relative amount of variation. The average measurements of central corneal thickness by a rotating Scheimpflug camera, scanning-slit topography, and ultrasonic pachymetry were 538+/-31.3 microm, 541+/-40.7 microm, and 545+/-31.3 microm, respectively. There were no statistically significant differences in the measurement results among the 3 methods (P = 0.569, repeated-measures analysis of variance). There was a significant linear correlation between the rotating Scheimpflug camera and ultrasonic pachymetry (r = 0.908, P<0.0001), rotating Scheimpflug camera and scanning-slit topography (r = 0.930, P<0.0001), and ultrasonic pachymetry and scanning-slit topography (r = 0.887, P<0.0001). Ultrasonic pachymetry had the smallest intraexaminer variability, and scanning-slit topography had the largest intraexaminer variability among the 3 methods. There were similar variations in interexaminer reproducibility among the 3 methods. Mean corneal

  16. Noncommutative Quantum Mechanics based on Representations of Exotic Galilei Group

    NASA Astrophysics Data System (ADS)

    Amorim, R. G. G.; Ulhoa, S. C.

    2018-02-01

    Using elements of symmetry, we constructed the Noncommutative Schrödinger Equation from a representation of Exotic Galilei Group. As a consequence, we derive the Ehrenfest theorem using noncommutative coordinates. We also have showed others features of quantum mechanics in such a manifold. As an important result, we find out that a linear potential in the noncommutative Schrödinger equation is completely analogous to the ordinary case. We also worked with harmonic and anharmonic oscillators, giving corrections in the energy for each one.

  17. Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging.

    PubMed

    Schuster, Alexander K; Schanzlin, David J; Thomas, Karin E; Heichel, Christopher W; Purcell, Tracy L; Barker, Patrick D

    2016-02-01

    To test a new method of intraocular lens (IOL) calculation after corneal refractive surgery using Scheimpflug imaging (Pentacam HR) and partial coherence interferometry (PCI) (IOLMaster) that does not require historical data; that is, the Schuster/Schanzlin-Thomas-Purcell (SToP) IOL calculator. Shiley Eye Center, San Diego, California, and Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Retrospective data analysis and validation study. Data were retrospectively collected from patient charts including data from Scheimpflug imaging and refractive history. Target refraction was calculated using PCI and the Holladay 1 and SRK/T formulas. Regression analysis was performed to explain the deviation of the target refraction, taking into account the following influencing factors: ratio of posterior-to-anterior corneal radius, axial length (AL), and anterior corneal radius. The regression analysis study included 61 eyes (39 patients) that had laser in situ keratomileusis (57 eyes) or photorefractive keratectomy (4 eyes) and subsequent cataract. Two factors were found that explained the deviation of the target refraction using the Holladay 1 formula; that is, the ratio of the corneal radii and the AL and the ratio of corneal radii for the SRK/T formula. A new IOL adjustment calculator was derived and validated at a second center using 14 eyes (10 patients). The error in IOL calculation for normal eyes after laser refractive treatment was related to the ratio of posterior-to-anterior corneal radius. A formula requiring Scheimpflug data and suggested IOL power only yielded an improved postoperative result for patients with previous corneal laser refractive surgery having cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. All rights reserved.

  18. Evaluation of corneal biomechanics in patients with keratectasia following LASIK using dynamic Scheimpflug analyzer.

    PubMed

    Ueki, Ryotaro; Maeda, Naoyuki; Fuchihata, Mutsumi; Asai, Tomoko; Koh, Shizuka; Fujimoto, Hisataka; Uematsu, Masafumi; Nishida, Kohji

    2018-04-26

    To investigate the corneal biomechanics in eyes with keratectasia following LASIK using a dynamic Scheimpflug analyzer. Case-Control study. The subjects in the study included 12 eyes with keratectasia after LASIK (KE), 24 eyes with keratoconus (KC), 17 eyes without keratectasia after LASIK (LASIK), and 34 eyes with normal corneas (Normal). Corneal biomechanics of the four groups were evaluated using a dynamic Scheimpflug analyzer. Compared with Normal (7.06 ± 0.54), the radius at the highest concavity (radius, mm) of LASIK (5.96 ± 0.76), KE (4.93 ± 0.61) and KC (5.39 ± 1.02) were significantly small. The Deflection Amplitude (HCDLA, mm) of Normal (0.94 ± 0.07) was significantly lower than those of KE (1.11 ± 0.10) and KC (1.06 ± 0.16), and was not significantly different from that of LASIK (0.98 ± 0.07). There were significant differences between LASIK and KE in radius and HCDLA (P < 0.05), whereas KE and KC had no differences in these parameters. Corneal biomechanical features evaluated using the dynamic Scheimpflug analyzer suggest that biomechanical properties in eyes with keratectasia, keratoconus, and LASIK are different from those of normal eyes. Although the biomechanics in eyes with keratectasia differs from that in eyes with LASIK, it is similar to that in eyes with keratoconus.

  19. Effect of posterior corneal astigmatism on refractive outcomes after toric intraocular lens implantation.

    PubMed

    Zhang, Lijun; Sy, Mary Ellen; Mai, Harry; Yu, Fei; Hamilton, D Rex

    2015-01-01

    To compare the prediction error after toric intraocular lens (IOL) (Acrysof IQ) implantation using corneal astigmatism measurements obtained with an IOLMaster automated keratometer and a Galilei dual rotating camera Scheimpflug-Placido tomographer. Jules Stein Eye Institute, University of California Los Angeles, Los Angeles, California, USA. Retrospective case series. The predicted residual astigmatism after toric IOL implantation was calculated using preoperative astigmatism values from an automated keratometer and the total corneal power (TCP) determined by ray tracing through the measured anterior and posterior corneal surfaces using dual Scheimpflug-Placido tomography. The prediction error was calculated as the difference between the predicted astigmatism and the manifest astigmatism at least 1 month postoperatively. The calculations included vector analysis. The study evaluated 35 eyes (35 patients). The preoperative corneal posterior astigmatism mean magnitude was 0.33 diopter (D) ± 0.16 (SD) (vector mean 0.23 × 176). Twenty-six eyes (74.3%) had with-the-rule (WTR) posterior astigmatism. The postoperative manifest refractive astigmatism mean magnitude was 0.38 ± 0.18 D (vector mean 0.26 × 171). There was no statistically significant difference in the mean magnitude prediction error between the automated keratometer and TCP techniques. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect against-the-rule (ATR) astigmatism. The TCP technique lacked these biases. The automated keratometer and TCP methods for estimating the magnitude of corneal astigmatism gave similar results. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect ATR astigmatism. Dr. Hamilton has received honoraria for educational lectures from Ziemer Ophthalmic Systems. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published

  20. Small-scale Scheimpflug lidar for aerosol extinction coefficient and vertical atmospheric transmittance detection.

    PubMed

    Sun, Guodong; Qin, Laian; Hou, Zaihong; Jing, Xu; He, Feng; Tan, Fengfu; Zhang, Silong

    2018-03-19

    In this paper, a new prototypical Scheimpflug lidar capable of detecting the aerosol extinction coefficient and vertical atmospheric transmittance at 1 km above the ground is described. The lidar system operates at 532 nm and can be used to detect aerosol extinction coefficients throughout an entire day. Then, the vertical atmospheric transmittance can be determined from the extinction coefficients with the equation of numerical integration in this area. CCD flat fielding of the image data is used to mitigate the effects of pixel sensitivity variation. An efficient method of two-dimensional wavelet transform according to a local threshold value has been proposed to reduce the Gaussian white noise in the lidar signal. Furthermore, a new iteration method of backscattering ratio based on genetic algorithm is presented to calculate the aerosol extinction coefficient and vertical atmospheric transmittance. Some simulations are performed to reduce the different levels of noise in the simulated signal in order to test the precision of the de-noising method and inversion algorithm. The simulation result shows that the root-mean-square errors of extinction coefficients are all less than 0.02 km -1 , and that the relative errors of the atmospheric transmittance between the model and inversion data are below 0.56% for all cases. The feasibility of the instrument and the inversion algorithm have also been verified by an optical experiment. The average relative errors of aerosol extinction coefficients between the Scheimpflug lidar and the conventional backscattering elastic lidar are 3.54% and 2.79% in the full overlap heights of two time points, respectively. This work opens up new possibilities of using a small-scale Scheimpflug lidar system for the remote sensing of atmospheric aerosols.

  1. Comparison of anterior chamber depth measurements by 3-dimensional optical coherence tomography, partial coherence interferometry biometry, Scheimpflug rotating camera imaging, and ultrasound biomicroscopy.

    PubMed

    Nakakura, Shunsuke; Mori, Etsuko; Nagatomi, Nozomi; Tabuchi, Hitoshi; Kiuchi, Yoshiaki

    2012-07-01

    To evaluate the congruity of anterior chamber depth (ACD) measurements using 4 devices. Saneikai Tsukazaki Hospital, Himeji City, Japan. Comparative case series. In 1 eye of 42 healthy participants, the ACD was measured by 3-dimensional corneal and anterior segment optical coherence tomography (CAS-OCT), partial coherence interferometry (PCI), Scheimpflug imaging, and ultrasound biomicroscopy (UBM). The differences between the measurements were evaluated by 2-way analysis of variance and post hoc analysis. Agreement between the measurements was evaluated using Bland-Altman analysis. To evaluate the true ACD using PCI, the automatically calculated ACD minus the central corneal thickness measured by CAS-OCT was defined as PCI true. Two ACD measurements were also taken with CAS-OCT. The mean ACD was 3.72 mm ± 0.23 (SD) (PCI), 3.18 ± 0.23 mm (PCI true), 3.24 ± 0.25 mm (Scheimpflug), 3.03 ± 0.25 mm (UBM), 3.14 ± 0.24 mm (CAS-OCT auto), and 3.12 ± 0.24 mm (CAS-OCT manual). A significant difference was observed between PCI biometry, Scheimpflug imaging, and UBM measurements and the other methods. Post hoc analysis showed no significant differences between PCI true and CAS-OCT auto or between CAS-OCT auto and CAS-OCT manual. Strong correlations were observed between all measurements; however, Bland-Altman analysis showed good agreement only between PCI true and Scheimpflug imaging and between CAS-OCT auto and CAS OCT manual. The ACD measurements obtained from PCI biometry, Scheimpflug imaging, CAS-OCT, and UBM were significantly different and not interchangeable except for PCI true and CAS-OCT auto and CAS-OCT auto and CAS-OCT manual. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Accuracy of Corneal Thickness by Swept-Source Optical Coherence Tomography and Scheimpflug Camera in Virgin and Treated Fuchs Endothelial Dystrophy.

    PubMed

    Arnalich-Montiel, Francisco; Ortiz-Toquero, Sara; Auladell, Clara; Couceiro, Ana

    2018-06-01

    To assess intraobserver repeatability, intersession reproducibility, and agreement of swept-source Fourier-domain optical coherence tomography (SS-OCT) and the Scheimpflug camera in measuring corneal thickness in virgin and grafted eyes with Fuchs endothelial corneal dystrophy (FECD). Thirty-six control eyes, 35 FECD eyes, 30 FECD with corneal edema eyes, 25 Descemet stripping automated endothelial keratoplasty (DSAEK) eyes, and 29 Descemet membrane endothelial keratoplasty (DMEK) eyes were included. The apical center, pupillary center, and thinnest corneal thickness were determined in 3 consecutive images and repeated 2 weeks later. Repeatability and reproducibility coefficients, intraclass correlation coefficients, and 95% limits of agreement (LOA) between measurements were calculated. Agreement between devices was assessed using Bland-Altman analysis. Corneal thickness measurements were highly reproducible and repeatable with both systems. SS-OCT showed better repeatability in all corneal locations in the normal, FECD, FECD with edema, DSAEK, and DMEK groups (coefficient of variation ≤0.60%, ≤0.36%, ≤0.43%, ≤1.09%, and ≤0.48%, respectively) than the Scheimpflug (coefficient of variation ≤1.15%, ≤0.92%, ≤1.10%, ≤1.25%, and ≤1.14%, respectively). Between-session 95% LOA for SS-OCT was less than 3% for all groups except for the FECD with edema group, being almost double using the Scheimpflug camera. Differences between instruments were statistically significant in all groups and locations (P < 0.01) except in the DSAEK group (P ≤ 0.51); however, SS-OCT underestimated all measurements. SS-OCT provides better reproducible and repeatable measurements of corneal thickness than those obtained with the Scheimpflug camera in patients with FECD or an endothelial transplant. Variations between examinations higher than the 95% LOA observed in our study should raise awareness of changes in the endothelial function.

  3. Glaucoma anterior chamber morphometry based on optical Scheimpflug images.

    PubMed

    Alonso, Ruiz Simonato; Ambrósio Junior, Renato; Paranhos Junior, Augusto; Sakata, Lisandro Massanori; Ventura, Marcelo Palis

    2010-01-01

    To compare the performance of gonioscopy and noncontact morphometry with anterior chamber tomography (High Resolution Pentacam - HR) using optical Scheimpflug images in the evaluation of the anterior chamber angle (ACA). Transversal study. 112 eyes from 74 subjects evaluated at the Glaucoma Department, Fluminense Federal University, underwent gonioscopy and Pentacam HR. Using gonioscopy, the ACA was graded using the Shaffer Classification (SC) by a single experienced examiner masked to the Pentacam HR findings. Narrow angle was determined in eyes in which the posterior trabecular meshwork could not be seen in two or more quadrants on non-indentation gonioscopy (SC Grade 2 or less). Pentacam HR images of the nasal and temporal quadrants were evaluated by custom software to automatically obtain anterior chamber measurements, such as: anterior chamber angle (ACA), anterior chamber volume (ACV) and anterior chamber depth (ACD). Based on gonioscopy results, 74 (60.07%) eyes of patients classified as open-angle (SC 3 and 4) and 38 (33.93%) eyes of patients classified as narrow-angle (SC 1 and 2). Noncontact morphometry with Scheimpflug images revealed a mean ACA of 39.20 ± 5.31 degrees for open-angle and 21.18 ± 7.98 degrees for narrow-angle. The open-angle group showed significant greater ACV and ACD values when compared to narrow-angle group (ACV of 193 ± 36 mm³ vs. 90 ± 25 mm³, respectively, p<0.001; and ACD of 3,09 ± 0,42 mm vs. 1,55 ± 0,64 mm, respectively, p<0.0001.). In screening eyes with open-angle and narrow-angle with the Pentacam ACA of 20º (SC Grade 2) using the ROC curves, the analysis showed 52.6% of sensitivity and 100% of specificity. The Pentacam showed ability in detecting eyes at risk for angle closure analyzing ACV and ACD.

  4. Seeds of a Tychonic Revolution: Telescopic Observations of the Stars by Galileo Galilei and Simon Marius

    NASA Astrophysics Data System (ADS)

    Graney, Christopher M.

    2010-03-01

    Because early telescopic astronomers did not understand the spurious nature of star images formed by their telescopes, their observations of the stars yielded data that apparently confirmed the geocentric Tychonic world system. Both Galileo Galilei (1564-1642) and Simon Marius (1570-1624) obtained such data. Galileo backed Nicholas Copernicus (1473-1543) despite his data. Marius supported Tycho Brahe (1546-1601) on the basis of his data.

  5. Clear-cornea cataract surgery: pupil size and shape changes, along with anterior chamber volume and depth changes. A Scheimpflug imaging study.

    PubMed

    Kanellopoulos, Anastasios John; Asimellis, George

    2014-01-01

    To investigate, by high-precision digital analysis of data provided by Scheimpflug imaging, changes in pupil size and shape and anterior chamber (AC) parameters following cataract surgery. The study group (86 eyes, patient age 70.58±10.33 years) was subjected to cataract removal surgery with in-the-bag intraocular lens implantation (pseudophakic). A control group of 75 healthy eyes (patient age 51.14±16.27 years) was employed for comparison. Scheimpflug imaging (preoperatively and 3 months postoperatively) was employed to investigate central corneal thickness, AC depth, and AC volume. In addition, by digitally analyzing the black-and-white dotted line pupil edge marking in the Scheimpflug "large maps," the horizontal and vertical pupil diameters were individually measured and the pupil eccentricity was calculated. The correlations between AC depth and pupil shape parameters versus patient age, as well as the postoperative AC and pupil size and shape changes, were investigated. Compared to preoperative measurements, AC depth and AC volume of the pseudophakic eyes increased by 0.99±0.46 mm (39%; P<0.001) and 43.57±24.59 mm(3) (36%; P<0.001), respectively. Pupil size analysis showed that the horizontal pupil diameter was reduced by -0.27±0.22 mm (-9.7%; P=0.001) and the vertical pupil diameter was reduced by -0.32±0.24 mm (-11%; P<0.001). Pupil eccentricity was reduced by -39.56%; P<0.001. Cataract extraction surgery appears to affect pupil size and shape, possibly in correlation to AC depth increase. This novel investigation based on digital analysis of Scheimpflug imaging data suggests that the cataract postoperative photopic pupil is reduced and more circular. These changes appear to be more significant with increasing patient age.

  6. Possible portrait of Galileo Galilei as a young scientist

    NASA Astrophysics Data System (ADS)

    Molaro, P.

    2012-02-01

    We describe here the possible discovery of a portrait of Galileo Galilei in his youth. The painting is not signed and the identification is mainly physiognomic. In fact, the face reveals clear resemblance to Domenico Tintoretto's portrait and to Giuseppe Calendi's engraving derived from a lost portrait made by Santi di Tito in 1601. Along with the portraits by Tintoretto, Furini, Leoni, Passignano, and Sustermans this could be another portrait of Galileo made al naturale, but, unlike the others, it depicts the scientist before he reached fame. Galileo looks rather young, at age of about 20-25 years. His eyes in the portrait are clear and the expression intense and appealing. From Galileo's correspondence we know of a portrait made by his friend Ludovico Cigoli. Rather interesting, though admittedly quite improbable, is the possibility of a self-portrait whose existence is mentioned in the first biography of Galileo by Salusbury in 1664.

  7. Galileo Galilei (GG): the space mission and the prototype

    NASA Astrophysics Data System (ADS)

    Nobili, A.

    "GALILEO GALILEI (GG)" is a proposal to fly a small satellite in low Earth orbit aiming to test the Equivalence Principle of Galileo, Newton and Einstein to 1 part in 1017 at room temperature. Ground tests carried out with artificial test bodies on rotating torsion balances, and tests with celestial bodies based on Lunar Laser Ranging data, have found no violation to about 1 part in 1013 . Competing space pro jects are SCOPE (also at room temperature) aiming to 1 part in 1015 , and STEP (at very low temperature) aiming to 1 part in 1018 . GG is characterized by fast rotation and by the possibility to perform a full scale test on the ground. This talk will present the main features of the GG design, as compared to STEP and SCOPE, and report the experimental results obtained with the first and the second generation laboratory prototypes (natural frequencies, quality factor, stability, sensitivity). Interested scientists are welcome to visit the GG webpage at http://eotvos.dm.unipi.it/nobili.

  8. Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis.

    PubMed

    Fukuda, Shinichi; Beheregaray, Simone; Hoshi, Sujin; Yamanari, Masahiro; Lim, Yiheng; Hiraoka, Takahiro; Yasuno, Yoshiaki; Oshika, Tetsuro

    2013-12-01

    To evaluate the ability of parameters measured by three-dimensional (3D) corneal and anterior segment optical coherence tomography (CAS-OCT) and a rotating Scheimpflug camera combined with a Placido topography system (Scheimpflug camera with topography) to discriminate between normal eyes and forme fruste keratoconus. Forty-eight eyes of 48 patients with keratoconus, 25 eyes of 25 patients with forme fruste keratoconus and 128 eyes of 128 normal subjects were evaluated. Anterior and posterior keratometric parameters (steep K, flat K, average K), elevation, topographic parameters, regular and irregular astigmatism (spherical, asymmetry, regular and higher-order astigmatism) and five pachymetric parameters (minimum, minimum-median, inferior-superior, inferotemporal-superonasal, vertical thinnest location of the cornea) were measured using 3D CAS-OCT and a Scheimpflug camera with topography. The area under the receiver operating curve (AUROC) was calculated to assess the discrimination ability. Compatibility and repeatability of both devices were evaluated. Posterior surface elevation showed higher AUROC values in discrimination analysis of forme fruste keratoconus using both devices. Both instruments showed significant linear correlations (p<0.05, Pearson's correlation coefficient) and good repeatability (ICCs: 0.885-0.999) for normal and forme fruste keratoconus. Posterior elevation was the best discrimination parameter for forme fruste keratoconus. Both instruments presented good correlation and repeatability for this condition.

  9. Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

    PubMed

    Nemeth, Gabor; Szalai, Eszter; Hassan, Ziad; Lipecz, Agnes; Flasko, Zsuzsa; Modis, Laszlo

    2017-01-01

    To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curvature radii on the anterior and posterior surfaces; apical pachymetry; corneal volume; corneal aberration data; depth, volume and angle of the anterior chamber) and axial length (AL) from IOLMaster were correlated with the 10 specific CorVis ST parameters. Measurements were conducted in 43 eyes of 43 volunteers (age 61.24±15.72y). The 10 specific CorVis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface, pachymetric data, root mean square (RMS) data of lower-order aberrations, and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea. Anterior chamber depth showed a significant relationship, but there were no significant correlations between corneal volume, anterior chamber volume, mean chamber angle or AL and the 10 specific CorVis ST parameters. CorVis ST-generated parameters are influenced by corneal curvature radii, some corneal RMS data, but corneal volume, anterior chamber volume, chamber angle and AL have no correlation with the biomechanical parameters. The parameters measured by CorVis ST seem to refer mostly to corneal properties of the eye.

  10. Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas

    PubMed Central

    Nemeth, Gabor; Szalai, Eszter; Hassan, Ziad; Lipecz, Agnes; Flasko, Zsuzsa; Modis, Laszlo

    2017-01-01

    AIM To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. METHODS Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curvature radii on the anterior and posterior surfaces; apical pachymetry; corneal volume; corneal aberration data; depth, volume and angle of the anterior chamber) and axial length (AL) from IOLMaster were correlated with the 10 specific CorVis ST parameters. RESULTS Measurements were conducted in 43 eyes of 43 volunteers (age 61.24±15.72y). The 10 specific CorVis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface, pachymetric data, root mean square (RMS) data of lower-order aberrations, and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea. Anterior chamber depth showed a significant relationship, but there were no significant correlations between corneal volume, anterior chamber volume, mean chamber angle or AL and the 10 specific CorVis ST parameters. CONCLUSIONS CorVis ST-generated parameters are influenced by corneal curvature radii, some corneal RMS data, but corneal volume, anterior chamber volume, chamber angle and AL have no correlation with the biomechanical parameters. The parameters measured by CorVis ST seem to refer mostly to corneal properties of the eye. PMID:28251079

  11. Scheimpflug image-based changes in anterior segment parameters during accommodation induced by short-term reading.

    PubMed

    Lipecz, Agnes; Tsorbatzoglou, Alexis; Hassan, Ziad; Berta, Andras; Modis, Laszlo; Nemeth, Gabor

    2017-05-11

    To analyze the effect of the accommodation on the anterior segment data (corneal and anterior chamber parameters) induced by short-time reading in a healthy, nonpresbyopic adult patient group. Images of both eyes of nonpresbyopic volunteers were captured with a Scheimpflug device (Pentacam HR) in a nonaccommodative state. Fifteen minutes of reading followed and through fixation of the built-in target of Pentacam HR further accommodation was achieved and new images were captured by the device. Anterior segment parameters were observed and the differences were analyzed. Fifty-two healthy eyes of 26 subjects (range 20.04-28.58 years) were analyzed. No significant differences were observed in the keratometric values before and after the accommodative task (p = 0.35). A statistically significant difference was measured in the 5.0-mm-diameter and the 7.0-mm-diameter corneal volume (p = 0.01 and p = 0.03) between accommodation states. Corneal aberrometric data did not change significantly during short-term accommodation. Significant differences were observed between nonaccommodative and accommodative states of the eyes for all measured anterior chamber parameters. Among the parameters of the cornea, only corneal volume changed during the short-term accommodation process, showing some fine changes with accommodation of the cornea in young, emmetropic patients. The position of the pupil and the anterior chamber parameters were observed to change with accommodation as captured by a Scheimpflug device.

  12. Scheimpflug topographical changes after Femtosecond LASIK for mixed astigmatism - theoretical aspects and case study.

    PubMed

    Tabacaru, Bogdana; Stanca, Horia Tudor

    2017-01-01

    Objective: To evaluate the corneal topographical changes after Femtosecond-LASIK surgery in eyes with mixed astigmatism. Methods: We present the analysis of the corneal Scheimpflug topographies of a patient treated with Femtosecond-LASIK technique for bilateral mixed astigmatism. Results: Three-dimensional reconstruction maps and differential anterior curvature maps were used to demonstrate the ablation profile and its stability in time. Conclusions: Visual and refractive results were very good after surgery, being topographically confirmed by the corneal reshaping which was performed as planned, the achieved ablation being stable during the one-year follow-up period.

  13. Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement.

    PubMed

    Penna, Rachele R; de Sanctis, Ugo; Catalano, Martina; Brusasco, Luca; Grignolo, Federico M

    2017-01-01

    To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0

  14. Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement

    PubMed Central

    Penna, Rachele R.; de Sanctis, Ugo; Catalano, Martina; Brusasco, Luca; Grignolo, Federico M.

    2017-01-01

    AIM To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). METHODS One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). RESULTS In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0

  15. Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles.

    PubMed

    Grewal, D S; Brar, G S; Jain, R; Grewal, S P S

    2011-05-01

    To compare the performance of anterior chamber volume (ACV) and anterior chamber depth (ACD) obtained using Scheimpflug imaging with angle opening distance (AOD500) and trabecular-iris space area (TISA500) obtained using spectral domain anterior segment optical coherence tomography (SD-ASOCT) in detecting narrow angles classified using gonioscopy. In this prospective, cross-sectional observational study, 265 eyes of 265 consecutive patients underwent sequential Scheimpflug imaging, SD-ASOCT imaging, and gonioscopy. Correlations between gonioscopy grading, ACV, ACD, AOD500, and TISA500 were evaluated. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LRs) were calculated to assess the performance of ACV, ACD, AOD500, and TISA500 in detecting narrow angles (defined as Shaffer grade ≤1 in all quadrants). SD-ASOCT images were obtained at the nasal and temporal quadrants only. Twenty-eight eyes (10.6%) were classified as narrow angles on gonioscopy. ACV correlated with gonioscopy grading (P<0.001) for temporal (r=0.204), superior (r=0.251), nasal (r=0.213), and inferior (r=0.236) quadrants. ACV correlated with TISA500 for nasal (r=0.135, P=0.029) and temporal (P=0.160, P=0.009) quadrants and also with AOD500 for nasal (r=0.498, P<0.001) and temporal (r=0.517, P<0.001) quadrants. For detection of narrow angles, ACV (AUC=0.935; 95% confidence interval (CI) =0.898-0.961) performed similar to ACD (AUC=0.88, P=0.06) and significantly better than AOD500 nasal (AUC=0.761, P=0.001), AOD500 temporal (AUC=0.808, P<0.001), TISA500 nasal (AUC=0.756, P<0.001), and TISA500 temporal (AUC=0.738, P<0.001). Using a cutoff of 113 mm(3), ACV had 90% sensitivity and 88% specificity for detecting narrow angles. Positive and negative LRs for ACV were 8.63 (95% CI=7.4-10.0) and 0.11 (95% CI=0.03-0.4), respectively. ACV measurements using Scheimpflug imaging outperformed AOD500 and TISA500 using SD-ASOCT for detecting narrow angles.

  16. Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles

    PubMed Central

    Grewal, D S; Brar, G S; Jain, R; Grewal, S P S

    2011-01-01

    Purpose To compare the performance of anterior chamber volume (ACV) and anterior chamber depth (ACD) obtained using Scheimpflug imaging with angle opening distance (AOD500) and trabecular-iris space area (TISA500) obtained using spectral domain anterior segment optical coherence tomography (SD-ASOCT) in detecting narrow angles classified using gonioscopy. Methods In this prospective, cross-sectional observational study, 265 eyes of 265 consecutive patients underwent sequential Scheimpflug imaging, SD-ASOCT imaging, and gonioscopy. Correlations between gonioscopy grading, ACV, ACD, AOD500, and TISA500 were evaluated. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LRs) were calculated to assess the performance of ACV, ACD, AOD500, and TISA500 in detecting narrow angles (defined as Shaffer grade ≤1 in all quadrants). SD-ASOCT images were obtained at the nasal and temporal quadrants only. Results Twenty-eight eyes (10.6%) were classified as narrow angles on gonioscopy. ACV correlated with gonioscopy grading (P<0.001) for temporal (r=0.204), superior (r=0.251), nasal (r=0.213), and inferior (r=0.236) quadrants. ACV correlated with TISA500 for nasal (r=0.135, P=0.029) and temporal (P=0.160, P=0.009) quadrants and also with AOD500 for nasal (r=0.498, P<0.001) and temporal (r=0.517, P<0.001) quadrants. For detection of narrow angles, ACV (AUC=0.935; 95% confidence interval (CI) =0.898–0.961) performed similar to ACD (AUC=0.88, P=0.06) and significantly better than AOD500 nasal (AUC=0.761, P=0.001), AOD500 temporal (AUC=0.808, P<0.001), TISA500 nasal (AUC=0.756, P<0.001), and TISA500 temporal (AUC=0.738, P<0.001). Using a cutoff of 113 mm3, ACV had 90% sensitivity and 88% specificity for detecting narrow angles. Positive and negative LRs for ACV were 8.63 (95% CI=7.4–10.0) and 0.11 (95% CI=0.03–0.4), respectively. Conclusions ACV measurements using Scheimpflug imaging outperformed AOD500 and TISA500 using

  17. Lenticonus diagnosis in Alport's syndrome: Anterior capsule apical angle calculation using Scheimpflug imagery.

    PubMed

    Jarrín, E; Jarrín, I; Arnalich-Montiel, F

    2015-08-01

    We describe a simplified method to detect anterior lenticonus. Three eyes of 2 patients with anterior lenticonus, plus 16 eyes from 16 healthy controls underwent Scheimpflug imaging of their anterior segment with Pentacam. The anterior capsule apex angle was manually identified and automatically measured by AutoCAD. The mean angle was 173.06° (SD: 1.91) in healthy subjects, and 158.33° (SD: 3.05) in anterior lenticonus eyes. The angle obtained from patients was more than 3 SD steeper than those from healthy subjects. The apical angle calculation method seems to discriminate well between normal eyes and eyes suspected of having anterior lenticonus. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  18. Scheimpflug with computational imaging to extend the depth of field of iris recognition systems

    NASA Astrophysics Data System (ADS)

    Sinharoy, Indranil

    Despite the enormous success of iris recognition in close-range and well-regulated spaces for biometric authentication, it has hitherto failed to gain wide-scale adoption in less controlled, public environments. The problem arises from a limitation in imaging called the depth of field (DOF): the limited range of distances beyond which subjects appear blurry in the image. The loss of spatial details in the iris image outside the small DOF limits the iris image capture to a small volume-the capture volume. Existing techniques to extend the capture volume are usually expensive, computationally intensive, or afflicted by noise. Is there a way to combine the classical Scheimpflug principle with the modern computational imaging techniques to extend the capture volume? The solution we found is, surprisingly, simple; yet, it provides several key advantages over existing approaches. Our method, called Angular Focus Stacking (AFS), consists of capturing a set of images while rotating the lens, followed by registration, and blending of the in-focus regions from the images in the stack. The theoretical underpinnings of AFS arose from a pair of new and general imaging models we developed for Scheimpflug imaging that directly incorporates the pupil parameters. The model revealed that we could register the images in the stack analytically if we pivot the lens at the center of its entrance pupil, rendering the registration process exact. Additionally, we found that a specific lens design further reduces the complexity of image registration making AFS suitable for real-time performance. We have demonstrated up to an order of magnitude improvement in the axial capture volume over conventional image capture without sacrificing optical resolution and signal-to-noise ratio. The total time required for capturing the set of images for AFS is less than the time needed for a single-exposure, conventional image for the same DOF and brightness level. The net reduction in capture time can

  19. Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

    PubMed

    Kirgiz, Ahmet; Atalay, Kurşat; Kaldirim, Havva; Cabuk, Kubra Serefoglu; Akdemir, Mehmet Orcun; Taskapili, Muhittin

    2017-08-01

    The purpose of this study was to compare the keratometry (K) values obtained by the Scheimpflug camera combined with placido-disk corneal topography (Sirius) and optical biometry (Lenstar) for intraocular lens (IOL) power calculation before the cataract surgery, and to evaluate the accuracy of postoperative refraction. 50 eyes of 40 patients were scheduled to have phacoemulsification with the implantation of a posterior chamber intraocular lens. The IOL power was calculated using the SRK/T formula with Lenstar K and K readings from Sirius. Simulated K (SimK), K at 3-, 5-, and 7-mm zones from Sirius were compared with Lenstar K readings. The accuracy of these parameters was determined by calculating the mean absolute error (MAE). The mean Lenstar K value was 44.05 diopters (D) ±1.93 (SD) and SimK, K at 3-, 5-, and 7-mm zones were 43.85 ± 1.91, 43.88 ± 1.9, 43.84 ± 1.9, 43.66 ± 1.85 D, respectively. There was no statistically significant difference between the K readings (P = 0.901). When Lenstar was used for the corneal power measurements, MAE was 0.42 ± 0.33 D, but when simK of Sirius was used, it was 0.37 ± 0.32 D (the lowest MAE (0.36 ± 0.32 D) was achieved as a result of 5 mm K measurement), but it was not statistically significant (P = 0.892). Of all the K readings of Sirius and Lenstar, Sirius 5-mm zone K readings were the best in predicting a more precise IOL power. The corneal power measurements with the Scheimpflug camera combined with placido-disk corneal topography can be safely used for IOL power calculation.

  20. Computerized Scheimpflug densitometry as a measure of corneal optical density after excimer laser refractive surgery in myopic eyes.

    PubMed

    Cennamo, Gilda; Forte, Raimondo; Aufiero, Bernardino; La Rana, Agostino

    2011-08-01

    To evaluate changes in anterior corneal optical density and the refractive index after photorefractive keratectomy (PRK) using a rotating Scheimpflug system. Department of Ophthalmology, University Federico II, Naples, Italy. Comparative case series. Anterior corneal optical density was evaluated with a rotating Scheimpflug system at baseline and 3 months and 12 months after PRK in eyes with a refractive error between -6.00 diopters (D) and -12.00 D (study group). A control group of unoperated eyes with the same refraction range was used to calculate corneal optical density and the Gladstone-Dale constant in unoperated eyes using the Gladstone-Dale formula. In the study group, changes in the anterior corneal optical density were evaluated over time and variations in the anterior corneal refractive index were obtained using the Gladstone-Dale constant. The study group comprised 37 eyes and the control group, 200 eyes. In the study group, the mean anterior corneal optical density and refractive index, respectively, were 27.71 ± 4.39 and 1.360 ± 0.05 at baseline, 37.812 ± 12.31 and 1.491 ± 0.16 after 3 months (P<.001 compared with baseline), and 26.29 ± 4.93 and 1.341 ± 0.06 after 12 months (P=.03 compared with baseline). The mean corneal optical density in the control group was 27.71 ± 4.31 (SD), and the resultant Gladstone-Dale constant was 0.013. An early increase and a subsequent reduction in anterior corneal optical density and the refractive index were present in myopic eyes during 1 year after PRK. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Galilei's astronomical discoveries using the telescope and their evaluation found in a writing-calendar from 1611

    NASA Astrophysics Data System (ADS)

    Herbst, K.-D.

    2009-06-01

    Yearly calendars were a mass-produced article in early modern times and had an enormous importance in everyday life. Besides a first part, the Calendarium with the monthly tables, they contain a second part, the astrological Prognosticum. At first, the two parts were sold separately. In the second half of the 17th century, the parts were designed as a unity and sold together. The calendars in quart format contain texts which are so interesting that historical research should give them more consideration. Such a text is found, e.g., in the second part of the calendar for 1611, written by Paul Nagel, astronomer and rector of the school in Torgau. Nagel informs about Galilei's discoveries with the telescope. The (Latin) text was written in August 1610. This text is presented and put into perspective in the scientific debates of the time about the telescope as a new invention with consequences to philosophy.

  2. Comparison of central corneal thickness and endothelial cell measurements by Scheimpflug camera system and two noncontact specular microscopes.

    PubMed

    Karaca, Irmak; Yilmaz, Suzan Guven; Palamar, Melis; Ates, Halil

    2017-07-03

    To investigate the correlation of Scheimpflug camera system and two noncontact specular microscopes in terms of central corneal thickness (CCT) and corneal endothelial cell morphology measurements. One hundred eyes of 50 healthy subjects were examined by Pentacam Scheimpflug Analyzer, CEM-530 (Nidek Co, Ltd, Gamagori, Japan) and CellChek XL (Konan Medical, California, USA) via fully automated image analysis with no corrections made. Measurement differences and agreement between instruments were determined by intraclass correlation analysis. The mean age of the subjects was 36.74 ± 8.59 (range 22-57). CCTs were well correlated among all devices, with having CEM-530 the thinnest and CellChek XL the thickest measurements (intraclass correlation coefficient (ICC) = 0.83; p < 0.001 and ICC = 0.78; p < 0.001, respectively). Mean endothelial cell density (ECD) given by CEM-530 was lower than CellChek XL (2613.17 ± 228.62 and 2862.72 ± 170.42 cells/mm 2 , respectively; ICC = 0.43; p < 0.001). Mean value for coefficient of variation (CV) was 28.57 ± 3.61 in CEM-530 and 30.30 ± 3.53 in CellChek XL. Cell hexagonality (HEX) with CEM-530 was higher than with CellChek XL (68.70 ± 4.16% and 45.19 ± 6.58%, respectively). ECDs with CellChek XL and CEM-530 have good correlation, but the values obtained by CellChek XL are higher than CEM-530. Measurements for HEX and CV differ significantly and show weak correlation. Thus, we do not recommend interchangeable use of CellChek XL and CEM-530. In terms of CCTs, Pentacam, CEM-530 and CellChek XL specular microscopy instruments are reliable devices.

  3. Analysis of the Viscoelastic Properties of the Human Cornea Using Scheimpflug Imaging in Inflation Experiment of Eye Globes

    PubMed Central

    Lombardo, Giuseppe; Serrao, Sebastiano; Rosati, Marianna; Lombardo, Marco

    2014-01-01

    Purpose To demonstrate a Scheimpflug-based imaging procedure for investigating the depth- and time-dependent strain response of the human cornea to inflation testing of whole eye globes. Methods Six specimens, three of which with intact corneal epithelium, were mounted in a customized apparatus within a humidity and temperature-monitored wet chamber. Each specimen was subjected to two mechanical tests in order to measure corneal strain resulting from application of cyclic (cyclic regimen) and constant (creep regimen) stress by changing the intra-ocular pressure (IOP) within physiological ranges (18–42 mmHg). Corneal shape changes were analyzed as a function of IOP and both corneal stress-strain curves and creep curves were generated. Results The procedure was highly accurate and repeatable. Upon cyclic stress application, a biomechanical corneal elasticity gradient was found in the front-back direction. The average Young's modulus of the anterior cornea ranged between 2.28±0.87 MPa and 3.30±0.90 MPa in specimens with and without intact epithelium (P = 0.05) respectively. The Young's modulus of the posterior cornea was on average 0.21±0.09 MPa and 0.17±0.06 MPa (P>0.05) respectively. The time-dependent strain response of the cornea to creep testing was quantified by fitting data to a modified Zener model for extracting both the relaxation time and compliance function. Conclusion Cyclic and creep mechanical tests are valuable for investigating the strain response of the intact human cornea within physiological IOP ranges, providing meaningful results that can be translated to clinic. The presence of epithelium influences the results of anterior corneal shape changes when monitoring deformation via Scheimpflug imaging in inflation experiments of whole eye globes. PMID:25397674

  4. Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking

    PubMed Central

    Hassan, Ziad; Modis, Laszlo; Szalai, Eszter; Berta, Andras; Nemeth, Gabor

    2014-01-01

    AIM To compare the anterior and posterior corneal parameters before and after collagen cross-linking therapy for keratoconus. METHODS Collagen cross-linking was performed in 31 eyes of 31 keratoconus patients (mean age 30.6±8.9y). Prior to treatment and an average 7mo after therapy, Scheimpflug analysis was performed using Pentacam HR. In addition to corneal thickness assessments, corneal radius, elevation, and aberrometric measurements were performed both on anterior and posterior corneal surfaces. Data obtained before and after surgery were statistically analyzed. RESULTS In terms of horizontal and vertical corneal radius, and central corneal thickness no deviations were observed an average 7mo after operation. Corneal higher order aberration showed no difference neither on anterior nor on posterior corneal surfaces. During follow-up period, no significant deviation was detected regarding elevation values obtained by measurement in mm units between the 3.0-8.0 mm-zones. CONCLUSION Corneal stabilization could be observed in terms of anterior and posterior corneal surfaces, elevation and higher order aberration values 7mo after collagen cross-linking therapy for keratoconus. PMID:24790876

  5. Galileo's eye: a new vision of the senses in the work of Galileo Galilei.

    PubMed

    Piccolino, Marco; Wade, Nicholas J

    2008-01-01

    Reflections on the senses, and particularly on vision, permeate the writings of Galileo Galilei, one of the main protagonists of the scientific revolution. This aspect of his work has received scant attention by historians, in spite of its importance for his achievements in astronomy, and also for the significance in the innovative scientific methodology he fostered. Galileo's vision pursued a different path from the main stream of the then contemporary studies in the field; these were concerned with the dioptrics and anatomy of the eye, as elaborated mainly by Johannes Kepler and Christoph Scheiner. Galileo was more concerned with the phenomenology rather than with the mechanisms of the visual process. His general interest in the senses was psychological and philosophical; it reflected the fallacies and limits of the senses and the ways in which scientific knowledge of the world could be gathered from potentially deceptive appearances. Galileo's innovative conception of the relation between the senses and external reality contrasted with the classical tradition dominated by Aristotle; it paved the way for the modern understanding of sensory processing, culminating two centuries later in Johannes Müller's elaboration of the doctrine of specific nerve energies and in Helmholtz's general theory of perception.

  6. Determination of excimer laser ablation rate of the human cornea using in vivo Scheimpflug videography.

    PubMed

    Huebscher, H J; Genth, U; Seiler, T

    1996-01-01

    To determine in vivo the amount of human corneal tissue removed by each excimer laser pulse, the so-called ablation rate, during photorefractive keratectomy (PRK). There is confusion in the literature because the experimentally determined ablation rate of 0.4 to 0.5 microns per pulse differs from the nominal ablation rate of 0.23 to 0.3 microns per pulse, which is the value used in clinical procedures. Eleven eyes of 11 patients were treated with PRK for correction of myopia. The corneal curvature was determined by Scheimpflug videography before and immediately after surgery. Starting from this curvature change, the authors calculated the real ablation rate. The real ablation rate is coincident with the nominal ablation rate and differs significantly from the ablation rate derived from deep keratectomy experiments. The outer layers of the cornea show significantly different ablation behavior than the deeper stroma. This information has clinical relevance for the predictability of intrastromal excimer laser procedures.

  7. Correction on the distortion of Scheimpflug imaging for dynamic central corneal thickness

    NASA Astrophysics Data System (ADS)

    Li, Tianjie; Tian, Lei; Wang, Like; Hon, Ying; Lam, Andrew K. C.; Huang, Yifei; Wang, Yuanyuan; Zheng, Yongping

    2015-05-01

    The measurement of central corneal thickness (CCT) is important in ophthalmology. Most studies concerned the value at normal status, while rare ones focused on its dynamic changing. The commercial Corvis ST is the only commercial device currently available to visualize the two-dimensional image of dynamic corneal profiles during an air puff indentation. However, the directly observed CCT involves the Scheimpflug distortion, thus misleading the clinical diagnosis. This study aimed to correct the distortion for better measuring the dynamic CCTs. The optical path was first derived to consider the influence of factors on the use of Covis ST. A correction method was then proposed to estimate the CCT at any time during air puff indentation. Simulation results demonstrated the feasibility of the intuitive-feasible calibration for measuring the stationary CCT and indicated the necessity of correction when air puffed. Experiments on three contact lenses and four human corneas verified the prediction that the CCT would be underestimated when the improper calibration was conducted for air and overestimated when it was conducted on contact lenses made of polymethylmethacrylate. Using the proposed method, the CCT was finally observed to increase by 66±34 μm at highest concavity in 48 normal human corneas.

  8. Three-dimensional microscopic tomographic imagings of the cataract in a human lens in vivo

    NASA Astrophysics Data System (ADS)

    Masters, Barry R.

    1998-10-01

    The problem of three-dimensional visualization of a human lens in vivo has been solved by a technique of volume rendering a transformed series of 60 rotated Scheimpflug (a dual slit reflected light microscope) digital images. The data set was obtained by rotating the Scheimpflug camera about the optic axis of the lens in 3 degree increments. The transformed set of optical sections were first aligned to correct for small eye movements, and then rendered into a volume reconstruction with volume rendering computer graphics techniques. To help visualize the distribution of lens opacities (cataracts) in the living, human lens the intensity of light scattering was pseudocolor coded and the cataract opacities were displayed as a movie.

  9. A novel Hartman Shack-based topography system: repeatability and agreement for corneal power with Scheimpflug+Placido topographer and rotating prism auto-keratorefractor.

    PubMed

    Prakash, Gaurav; Srivastava, Dhruv; Choudhuri, Sounak

    2015-12-01

    The purpose of this study is to analyze the repeatability and agreement of corneal power using a new Hartman type topographer in comparison to Scheimpflug+Placido and autorefractor devices. In this cross sectional, observational study performed at the cornea services of a specialty hospital, 100 normal eyes (100 consecutive candidates) without any previous ocular surgery or morbidity except refractive error were evaluated. All candidates underwent three measurements each on a Full gradient, Hartman type topographer (FG) (iDesign, AMO), Scheimpflug+Placido topographer (SP) (Sirius, CSO) and rotating prism auto-keratorefractor (AR) (KR1, Nidek). The parameters assessed were flat keratometry (K1), steep keratometry (K2), steep axis (K2 axis), mean K, J 0 and J 45. Intra-device repeatability and inter-device agreement were evaluated. On repeatability analysis, the intra-device means were not significantly different (ANOVA, p > 0.05). Intraclass correlations (ICC) were >0.98 except for J 0 and J 45. In terms of intra-measurement standard deviation (Sw), the SP and FG groups fared better than AR group (p < 0.001, ANOVA). On Sw versus Average plots, no significantly predictive fit was seen (p > 0.05, R (2) < 0.1 for all the values). On inter-device agreement analysis, there was no difference in means (ANOVA, p > 0.05). ICC ranged from 0.92 to 0.99 (p < 0.001). Regression fits on Bland-Altman plots suggested no clinically significant effect of average values over difference in means. The repeatability of Hartman type topographer in normal eyes is comparable to SP combination device and better than AR. The agreement between the three devices is good. However, we recommend against interchanging these devices between follow-ups or pooling their data.

  10. Dynamical response of the Galileo Galilei on the ground rotor to test the equivalence principle: Theory, simulation, and experiment. II. The rejection of common mode forces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Comandi, G.L.; Toncelli, R.; Chiofalo, M.L.

    'Galileo Galilei on the ground' (GGG) is a fast rotating differential accelerometer designed to test the equivalence principle (EP). Its sensitivity to differential effects, such as the effect of an EP violation, depends crucially on the capability of the accelerometer to reject all effects acting in common mode. By applying the theoretical and simulation methods reported in Part I of this work, and tested therein against experimental data, we predict the occurrence of an enhanced common mode rejection of the GGG accelerometer. We demonstrate that the best rejection of common mode disturbances can be tuned in a controlled way bymore » varying the spin frequency of the GGG rotor.« less

  11. Comparative Evaluation of the Corneal and Anterior Chamber Parameters Derived From Scheimpflug Imaging in Arab and South Asian Normal Eyes.

    PubMed

    Prakash, Gaurav; Srivastava, Dhruv; Avadhani, Kavitha; Thirumalai, Sandeep M; Choudhuri, Sounak

    2015-11-01

    To evaluate the differences in the normal corneal and anterior segment Scheimpflug parameters in Arab and South Asian eyes. This hospital-based study was performed at a cornea and refractive surgery service in Abu Dhabi. A total of 600 consecutive normal candidates of South Asian (group 1, n = 300) and Arab (group 2, n = 300) origins underwent Scheimpflug imaging (Sirius; Costruzione Strumenti Oftalmici, Italy). One eye was randomly selected for evaluation. The age and sex distributions in both groups were comparable. The pachymetric variables were statistically higher in group 2 (group 2 vs. group 1, 544.3 ± 32.2 μm vs. 535.1 ± 31.4 μm for central corneal thickness, 541.0 ± 32.6 μm vs. 531.9 ± 31.5 μm for minimum corneal thickness, 571.7 ± 43.2 μm vs. 558.1 ± 42.3 μm for apical thickness, and 58.1 ± 4.2 vs. 57.3 ± 4.3 mm³ for the corneal volume; P < 0.05). The anterior chamber volume (group 2 vs. group 1: 166.4 ± 16.4 vs. 161.6 ± 20.5 mm³) and angle (group 2 vs. group 1: 44.6 ± 6.2 vs. 43.5 ± 5.8 degrees) were also higher for group 2 (P < 0.05). Central corneal curvature and apical corneal curvature (apex K) were higher in group 1 (P < 0.05) with comparable astigmatism. The flat keratometry (K), steep K, and apex K were 43.6 ± 2.2 diopters (D), 44.9 ± 1.8 D, and 45.7 ± 1.8 D for group 1, and 43.1 ± 2.2 D, 44.5 ± 2 D, and 45.2 ± 1.9 D for group 2. The effect size (Cohen d) for significant parameters ranged from 0.2 to 0.3. Normal eyes of Arab ethnicity tend to have statistically thicker and flatter corneas and less-crowded anterior segments than those of the South Asian counterparts. These epidemiological differences have a mild to moderate biological effect size (Cohen d), but they should be considered when evaluating these eyes for anterior segment or corneal procedures.

  12. Distribution of the anterior, posterior, and total corneal astigmatism in healthy eyes.

    PubMed

    Feizi, Sepehr; Naderan, Mohammad; Ownagh, Vahid; Sadeghpour, Fatemeh

    2018-04-01

    To evaluate the magnitude and axis orientation of the anterior, posterior, and total corneal astigmatism in normal healthy eyes of an Iranian population. In a prospective cross-sectional study, ophthalmic and anterior segment parameters of 153 healthy eyes of 153 subjects were evaluated by Galilei dual Scheimpflug analyzer. The magnitude and axis orientation [with-the-rule (WTR), against-the-rule (ATR), and oblique] of the anterior, posterior, and total corneal astigmatism measurements (ACA, PCA, and TCA) were compared according to the age, sex, and other ophthalmic parameters. The mean ± SD age of the study population was 30 ± 5.9 years. The mean magnitude was 1.09 ± 0.76 diopters (D) for ACA, 0.30 ± 0.13 D for PCA, and 1.08 ± 0.77 D for TCA. Males had a significantly higher magnitude of PCA than females (p = 0.041). Most eyes had a WTR anterior astigmatism and an ATR posterior astigmatism. The WTR astigmatism had a higher mean magnitude compared to the ATR and oblique astigmatism in all the astigmatism groups, with a significant difference in the ACA and TCA groups (p < 0.05). PCA magnitude exceeded 0.50 D in only 7.8% of the subjects. ACA, PCA, and TCA were significantly correlated with each other and also had a significant correlation with the anterior and posterior maximum corneal elevation measurements (p < 0.001). The results of this study although are limited due to the small number of participants and confined to our demographics, provided information regarding a population that was not described before and may be helpful in obtaining optimum results in astigmatism correction in refractive surgery or designing new intraocular lenses.

  13. Mean Posterior Corneal Power and Astigmatism in Normal Versus Keratoconic Eyes.

    PubMed

    Feizi, Sepehr; Delfazayebaher, Siamak; Javadi, Mohammad Ali; Karimian, Farid; Ownagh, Vahid; Sadeghpour, Fatemeh

    2018-01-01

    To compare mean posterior corneal power and astigmatism in normal versus keratoconus affected eyes and determine the optimal cut-off points to maximize sensitivity and specificity in discriminating keratoconus from normal corneas. A total of 204 normal eyes and 142 keratoconus affected eyes were enrolled in this prospective comparative study. Mean posterior corneal power and astigmatism were measured using a dual Scheimpflug camera. Correlation coefficients were calculated to assess the relationship between the magnitudes of keratometric and posterior corneal astigmatism in the study groups. Receiver operating characteristic curves were used to compare the sensitivity and specificity of the measured parameters and to identify the optimal cut-off points for discriminating keratoconus from normal corneas. The mean posterior corneal power was -6.29 ± 0.20 D in the normal group and -7.77 ± 0.87 D in the keratoconus group ( P < 0.001). The mean magnitudes of the posterior corneal astigmatisms were -0.32 ± 0.15 D and -0.94 ± 0.39 D in the normal and keratoconus groups, respectively ( P < 0.001). Significant correlations were found between the magnitudes of keratometric and posterior corneal astigmatism in the normal (r=-0.76, P < 0.001) and keratoconus (r=-0.72, P < 0.001) groups. The mean posterior corneal power and astigmatism were highly reliable characteristics that distinguished keratoconus from normal corneas (area under the curve, 0.99 and 0.95, respectively). The optimal cut-off points of mean posterior corneal power and astigmatism were -6.70 D and -0.54 D, respectively. Mean posterior corneal power and astigmatism measured using a Galilei analyzer camera might have potential in diagnosing keratoconus. The cut-off points provided can be used for keratoconus screening.

  14. Correlation of higher order aberrations in the anterior corneal surface and degree of keratoconus measured with a Scheimpflug camera.

    PubMed

    Delgado, S; Velazco, J; Delgado Pelayo, R M; Ruiz-Quintero, N

    2016-07-01

    To determine the correlation of higher order aberrations in anterior corneal surface and degree of keratoconus measured with a Scheimpflug camera. A descriptive, cross-sectional study was conducted on 152 eyes (both eyes of each patient) of patients with keratoconus, from January 2009 to April 2014. An examination was performed on the corneal aberrometry in the anterior corneal surface, and topographic mapping (by Amsler and Muckenhirn classification) was used to determine the degree of keratoconus. The correlation between high-order aberrations in anterior corneal surface and the degree of keratoconus was determined. Coma aberration significantly correlated with keratoconus severity (r=.60, P<.01), as well as with the high order aberration (r=.61, P<.01). Trefoil and keratoconus were weakly correlated (r=.34, P<.01). Higher order aberrations in anterior corneal surface were positively correlated with the degree of keratoconus in a similar way to the entire optical system. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  15. The enigma of Galileo's eyesight: some novel observations on Galileo Galilei's vision and his progression to blindness.

    PubMed

    Watson, Peter G

    2009-01-01

    Galileo Galilei became blind. Before this happened he revealed that his left eye had always had less than perfect vision. A study of his written works, his handwriting, and the originals of the portraits undertaken during his lifetime indicate that this probably was the case. These portraits suggest that his left eye tended to lose fixation and that, at the age of 60, he suffered from a mucocoele of the right frontal sinus; but these conditions would not have caused blindness. Considering the systemic diseases from which he suffered over his lifetime, he could possibly have had a long standing uveitis with secondary pupillary block glaucoma, common in those with the group of conditions classified as sero-negative arthropathies. Posterior scleritis with secondary glaucoma is less likely. If either of these were the cause, then the disease was probably triggered by a well-documented, severe acute illness as a young adult, the inflammation being localized to the eye as a result of severe recurrent conjunctival infections in his youth. The intermittent nature of the visual loss, the normal appearance of the cornea and pupils in his portraits, the absence of any evidence of inflammatory joint disease, the presence of halos, and the severe nature of the pain-combined with the high level of visual acuity in between attacks and its persistence until the last few weeks of vision means that angle-closure glaucoma must also be considered. These suggestions might be confirmed or refuted by studying his remains. Application has been made for this to be done.

  16. Reliability of Corneal Dynamic Scheimpflug Analyser Measurements in Virgin and Post-PRK Eyes

    PubMed Central

    Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske

    2014-01-01

    Purpose To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Methods Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. Results The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05). Conclusions CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter. PMID:25302580

  17. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    PubMed

    Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske

    2014-01-01

    To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  18. Carroll versus Newton and Galilei: two dual non-Einsteinian concepts of time

    NASA Astrophysics Data System (ADS)

    Duval, C.; Gibbons, G. W.; Horvathy, P. A.; Zhang, P. M.

    2014-04-01

    The Carroll group was originally introduced by Lévy-Leblond (1965 Ann. Inst. Henri Poincaré 3 1) by considering the contraction of the Poincaré group as c → 0. In this paper an alternative definition, based on the geometric properties of a non-Minkowskian, non-Galilean but nevertheless boost-invariant, spacetime structure is proposed. A ‘duality’ with the Galilean limit c → ∞ is established. Our theory is illustrated by Carrollian electromagnetism.

  19. Multimodal Assessment of Corneal Thinning Using Optical Coherence Tomography, Scheimpflug Imaging, Pachymetry, and Slit-Lamp Examination.

    PubMed

    Oatts, Julius T; Keenan, Jeremy D; Mannis, Tova; Lietman, Tom M; Rose-Nussbaumer, Jennifer

    2017-04-01

    To assess the relationship between corneal thinning measured by clinician-graded slit-lamp examination compared with ultrasound pachymetry (USP), anterior segment optical coherence tomography (AS-OCT), and the Pentacam. Patients with corneal thinning underwent USP, AS-OCT, Pentacam measurements and standardized clinical grading by 2 cornea specialists estimating thinning on slit-lamp examination. Reproducibility of each testing modality was assessed using the intraclass correlation coefficient. Bland-Altman plots were used to determine precision and limits of agreement (LOA) between imaging modalities and clinical grading. We included 22 patients with corneal thinning secondary to infectious or inflammatory keratitis. Mean percent stromal thinning estimated by grader 1 was 51% (SD 31) and grader 2 was 49% (SD 33). The intraclass correlation coefficient between the masked examiners was 0.95 (95% confidence interval, 0.88-0.98). Graders were more similar to each other than to any other modality with 2% difference and 4.6% of measurements outside the LOA. When measuring the area of maximum thinning, AS-OCT measured approximately 10% thicker than human graders while the Pentacam measured approximately 10% thinner than human graders with 16.7% outside the LOA. USP measured approximately 20% thinner than human graders with 5.6% outside the LOA. Trained corneal specialists have a high degree of agreement in location and degree of corneal thinning when measured in a standardized fashion on the same day. Other testing modalities had acceptable reproducibility and agreement with clinical examination and each other, although Scheimpflug imaging fared worse for corneal thinning, particularly in the periphery, than the other modalities.

  20. Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology.

    PubMed

    He, Miao; Ding, Hui; He, Hong; Zhang, Chi; Liu, Liangping; Zhong, Xingwu

    2017-05-17

    The aim of this study was to evaluate corneal biomechanical properties in a population of healthy children in China using corneal visualization Scheimpflug technology (CST). All children underwent complete bi-ocular examinations. CST provided intraocular pressure (IOP) and corneal biomechanical parameters, including time, velocity, length and deformation amplitude at first applanation (A1T, A1V, A1L, A1DA), at second applanation (A2T, A2V, A2L, A2DA), highest concavity time (HCT), maximum deformation amplitude (MDA), peak distance (PD), and radius of curvature (RoC). Pearson correlation analysis was used to assess the impacts of demographic factors, central corneal thickness (CCT), spherical equivalent (SE), and IOP on corneal biomechanics. One hundred eight subjects (32 girls and 76 boys) with the mean age of 10.80 ± 4.13 years (range 4 to18 years) were included in the final analyses. The right and left eyes were highly symmetrical in SE (p = 0.082), IOP (p = 0.235), or CCT (p = 0.210). Mean A1T of the right eyes was 7.424 ± 0.340 ms; the left eyes 7.451 ± 0.365 ms. MDA was 0.993 ± 0.102 mm in the right eyes and 0.982 ± 0.100 mm in the left eyes. Mean HCT of the right eyes was 16.675 ± 0.502 ms; the left eyes 16.735 ± 0.555 ms. All CST parameters of both eye were remarkably symmetrical with the exception of A2L (p = 0.006), A1DA (p = 0.025). The majority of CST parameters of both eyes were significantly correlated with CCT and IOP (p < 0.05). However, age, SE, and sex exert little influence on the CST measurements. This study found interocular symmetry in corneal biomechanics in healthy children eyes. Several CST biomechanical parameters in children are modified by CCT and IOP.

  1. Comparison of central corneal thickness measurements with a rotating scheimpflug camera, a specular microscope, optical low-coherence reflectometry, and ultrasound pachymetry in keratoconic eyes.

    PubMed

    Cinar, Yasin; Cingu, Abdullah Kursat; Turkcu, Fatih Mehmet; Cinar, Tuba; Sahin, Alparslan; Yuksel, Harun; Ari, Seyhmus

    2015-03-01

    To compare central corneal thickness (CCT) measurements with a rotating Scheimpflug camera (RSC), noncontact specular microscopy (SM), optical low-coherence reflectometry (OLCR), and ultrasonic pachymetry (UP) in keratoconus (KC) patients. In this prospective study, four CCT measurements taken with an RSC, SM, OLCR, and UP were compared in 81 eyes of 44 consecutive KC patients. The KC patients were divided into four subgroups according to Amsler-Krumeich's KC classification. The RSC and UP measurements of the CCT were not statistically significant in all the groups. Comparison of the SM vs. the OLCR measurements yielded statistically significant differences in all the KC patients and in all KC stages. In all the KC patients, RSC and OLCR showed a high correlation coefficient factor (r = 0.87, p = 0.000). CCT measurements with RSC are comparable to those achieved with UP. Compared with the other devices, according to SM measurements, the central cornea is thicker in all keratoconic eyes and in all KC grades, and it is thinner according to OLCR. RSC, UP, SM, and OLCR should not be used interchangeably in keratoconic eyes.

  2. Dual-fuel, dual-throat engine preliminary analysis

    NASA Technical Reports Server (NTRS)

    Obrien, C. J.

    1979-01-01

    A propulsion system analysis of the dual fuel, dual throat engine for launch vehicle applications was conducted. Basic dual throat engine characterization data were obtained to allow vehicle optimization studies to be conducted. A preliminary baseline engine system was defined.

  3. Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE).

    PubMed

    Shen, Yang; Su, Xiangjian; Liu, Xiu; Miao, Huamao; Fang, Xuejun; Zhou, Xingtao

    2016-11-18

    Corneal biomechanical properties are always compromised after corneal refractive surgeries thus leading to underestimated intraocular pressure (IOP) that complicates the management of IOP. We investigated the changes in postoperative baseline of IOP values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology (CST) in the early phase after small incision lenticule extraction (SMILE). Twenty-two eyes (-6.76 ± 1.39D) of 22 moderate and high myopes, (28.36 ± 7.14 years, 12 male and 10 female) were involved in this prospective study. IOP values were measured using a non-contact tomometer (NCT-IOP), an ocular response analyzer (corneal-compensated IOP, IOPcc and Goldmann-correlated IOP, IOPg) and a Corvis scheimpflug technology tonometer (CST-IOP) preoperatively, at 20 min and 24 h, postoperatively. Repeated measures analysis of variance (RM-ANOVA), Pearson's correlation analysis and multiple linear regression models (stepwise) were performed. Cut-off P values were 0.05. Except for IOPcc, NCT-IOP, IOPg, and CST-IOP values significantly decreased after SMILE procedure (All P values <0.05). ΔCCT, as well as ΔMRSE and ΔKm, did not significantly correlated with ΔNCT-IOP, ΔIOPcc, ΔIOPg or ΔCST-IOP, (all P values >0.05). Multiple linear regression models (stepwise) showed that the practical post-operative IOP value was the main predictor of the theoretical post-operative NCT-IOP, IOPcc and IOPg values (all P values <0.001). The postoperative applanation time 1 (AT1) value (B = 8.079, t = 4.866, P < 0.001), preoperative central corneal thickness (CCT) value (B = 0.035, t = 2.732, P = 0.014) and postoperative peak distance (PD) value (B = 0.515, t = 2.176, P = 0.043) were the main predictors of the theoretical post-operative CST-IOP value. IOP values are underestimated when assessed after SMILE by using NCT-IOP, IOPg and CST-IOP. The practical postoperative IOPcc value

  4. Dual Credit/Dual Enrollment and Data Driven Policy Implementation

    ERIC Educational Resources Information Center

    Lichtenberger, Eric; Witt, M. Allison; Blankenberger, Bob; Franklin, Doug

    2014-01-01

    The use of dual credit has been expanding rapidly. Dual credit is a college course taken by a high school student for which both college and high school credit is given. Previous studies provided limited quantitative evidence that dual credit/dual enrollment is directly connected to positive student outcomes. In this study, predictive statistics…

  5. The bat-bird-bug battle: daily flight activity of insects and their predators over a rice field revealed by high-resolution Scheimpflug Lidar

    NASA Astrophysics Data System (ADS)

    Malmqvist, Elin; Jansson, Samuel; Zhu, Shiming; Li, Wansha; Svanberg, Katarina; Svanberg, Sune; Rydell, Jens; Song, Ziwei; Bood, Joakim; Brydegaard, Mikkel; Åkesson, Susanne

    2018-04-01

    We present the results of, to our knowledge, the first Lidar study applied to continuous and simultaneous monitoring of aerial insects, bats and birds. It illustrates how common patterns of flight activity, e.g. insect swarming around twilight, depend on predation risk and other constraints acting on the faunal components. Flight activity was monitored over a rice field in China during one week in July 2016, using a high-resolution Scheimpflug Lidar system. The monitored Lidar transect was about 520 m long and covered approximately 2.5 m3. The observed biomass spectrum was bimodal, and targets were separated into insects and vertebrates in a categorization supported by visual observations. Peak flight activity occurred at dusk and dawn, with a 37 min time difference between the bat and insect peaks. Hence, bats started to feed in declining insect activity after dusk and stopped before the rise in activity before dawn. A similar time difference between insects and birds may have occurred, but it was not obvious, perhaps because birds were relatively scarce. Our observations are consistent with the hypothesis that flight activity of bats is constrained by predation in bright light, and that crepuscular insects exploit this constraint by swarming near to sunset/sunrise to minimize predation from bats.

  6. Dual nozzle aerodynamic and cooling analysis study. [dual throat and dual expander nozzles

    NASA Technical Reports Server (NTRS)

    Meagher, G. M.

    1980-01-01

    Geometric, aerodynamic flow field, performance prediction, and heat transfer analyses are considered for two advanced chamber nozzle concepts applicable to Earth-to-orbit engine systems. Topics covered include improvements to the dual throat aerodynamic and performance prediction program; geometric and flow field analyses of the dual expander concept; heat transfer analysis of both concepts, and engineering analysis of data from the NASA/MSFC hot-fire testing of a dual throat thruster model thrust chamber assembly. Preliminary results obtained are presented in graphs.

  7. Comparison of anterior segment parameters and axial length measurements performed on a Scheimpflug device with biometry function and a reference optical biometer.

    PubMed

    Muzyka-Woźniak, Maria; Oleszko, Adam

    2018-04-26

    To compare measurements of axial length (AL), corneal curvature (K), anterior chamber depth (ACD) and white-to-white (WTW) distance on a new device combining Scheimpflug camera and partial coherence interferometry (Pentacam AXL) with a reference optical biometer (IOL Master 500). To evaluate differences between IOL power calculations based on the two biometers. Ninety-seven eyes of 97 consecutive cataract or refractive lens exchange patients were examined preoperatively on IOL Master 500 and Pentacam AXL units. Comparisons between two devices were performed for AL, K, ACD and WTW. Intraocular lens (IOL) power targeting emmetropia was calculated with SRK/T and Haigis formulas on both devices and compared. There were statistically significant differences between two devices for all measured parameters (P < 0.05), except ACD (P = 0.36). Corneal curvature measured with Pentacam AXL was significantly flatter then with IOL Master. The mean difference in AL was clinically insignificant (0.01 mm; 95% LoA 0.16 mm). Pentacam AXL yielded higher IOL power in 75% of eyes for Haigis formula and in 62% of eyes for SRK/T formula, with a mean difference within ± 0.5 D for 72 and 86% of eyes, respectively. There were statistically significant differences between AL, K and WTW measurements obtained with the compared biometers. Flatter corneal curvature measurements on Pentacam AXL necessitate formulas optimisation for Pentacam AXL.

  8. Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes.

    PubMed

    Choi, Young; Eom, Youngsub; Song, Jong Suk; Kim, Hyo Myung

    2018-05-15

    To compare the effect of posterior corneal astigmatism on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]) between eyes with keratoconus and healthy eyes. Thirty-three eyes of 33 patients with keratoconus of grade I or II and 33 eyes of 33 age- and sex-matched healthy control subjects were enrolled. Anterior, posterior, and total corneal cylinder powers and flat meridians measured by a single Scheimpflug camera were analyzed. The difference in corneal astigmatism between the simulated K and total cornea was evaluated. The mean anterior, posterior, and total corneal cylinder powers of the keratoconus group (4.37 ± 1.73, 0.95 ± 0.39, and 4.36 ± 1.74 CD, respectively) were significantly greater than those of the control group (1.10 ± 0.68, 0.39 ± 0.18, and 0.97 ± 0.63 CD, respectively). The cylinder power difference between the simulated K and total cornea was positively correlated with the posterior corneal cylinder power and negatively correlated with the absolute flat meridian difference between the simulated K and total cornea in both groups. The mean magnitude of the vector difference between the astigmatism of the simulated K and total cornea of the keratoconus group (0.67 ± 0.67 CD) was significantly larger than that of the control group (0.28 ± 0.12 CD). Eyes with keratoconus had greater estimation errors of total corneal astigmatism based on anterior corneal measurement than did healthy eyes. Posterior corneal surface measurement should be more emphasized to determine the total corneal astigmatism in eyes with keratoconus. © 2018 The Korean Ophthalmological Society.

  9. Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes

    PubMed Central

    Choi, Young; Song, Jong Suk; Kim, Hyo Myung

    2018-01-01

    Purpose To compare the effect of posterior corneal astigmatism on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]) between eyes with keratoconus and healthy eyes. Methods Thirty-three eyes of 33 patients with keratoconus of grade I or II and 33 eyes of 33 age- and sex-matched healthy control subjects were enrolled. Anterior, posterior, and total corneal cylinder powers and flat meridians measured by a single Scheimpflug camera were analyzed. The difference in corneal astigmatism between the simulated K and total cornea was evaluated. Results The mean anterior, posterior, and total corneal cylinder powers of the keratoconus group (4.37 ± 1.73, 0.95 ± 0.39, and 4.36 ± 1.74 cylinder diopters [CD], respectively) were significantly greater than those of the control group (1.10 ± 0.68, 0.39 ± 0.18, and 0.97 ± 0.63 CD, respectively). The cylinder power difference between the simulated K and total cornea was positively correlated with the posterior corneal cylinder power and negatively correlated with the absolute flat meridian difference between the simulated K and total cornea in both groups. The mean magnitude of the vector difference between the astigmatism of the simulated K and total cornea of the keratoconus group (0.67 ± 0.67 CD) was significantly larger than that of the control group (0.28 ± 0.12 CD). Conclusions Eyes with keratoconus had greater estimation errors of total corneal astigmatism based on anterior corneal measurement than did healthy eyes. Posterior corneal surface measurement should be more emphasized to determine the total corneal astigmatism in eyes with keratoconus. PMID:29770640

  10. The contribution of Giordano Bruno to the principle of relativity

    NASA Astrophysics Data System (ADS)

    De Angelis, Alessandro; Santo, Catarina Espirito

    2015-11-01

    The trial and condemnation of Giordano Bruno was mainly based on arguments of a philosophical and theological nature, and therefore different from Galileo Galilei's trial. Such elements contribute to unfairly devalue the scientific contribution of Bruno and do not properly account for his contribution to physics. This paper discusses the contribution that Bruno made to the principle of relativity. This was first discussed by Galileo Galilei in 1632 using the metaphor known today as 'Galileo's ship', but we shall show that this same metaphor and some of the examples in Galileo's book were already contained in a dialogue published by Bruno in 1584. In fact, Bruno largely anticipated the arguments of Galilei on the relativity principle, in particular to support the Copernican view. It is likely that Galilei was aware of Bruno's work, and it is possible that the young Galilei discussed it with Bruno, since they both stayed in Venice for long periods in 1592.

  11. Dual Protection and Dual Methods in Women Living with HIV: The Brazilian Context

    PubMed Central

    Barbosa, Regina María; Pinho, Adriana de Araujo

    2013-01-01

    The cooccurrence of HIV and unintended pregnancy has prompted a body of work on dual protection, the simultaneous protection against HIV and unintended pregnancy. This study examines dual protection and dual methods as a risk-reduction strategy for women living with HIV. Data are from a cross-sectional sample of HIV-positive women attended in Specialized STI/AIDS Public Health Service Clinics in 13 municipalities from all five regions of Brazil 2003-2004 (N = 834). Descriptive techniques and logistic regression were used to examine dual protection among women living with HIV. We expand the definition of dual protection to include consistent condom use and reversible/irreversible contraceptive methods, we test the dual methods hypothesis that women who use dual methods will use condoms less consistently than women who use only condoms, and we identify predictors of dual protection. Dual protection is common in our sample. Women who use dual methods have lower odds of consistent condom use than women who only use condoms. Among dual method users, we find that women who use an irreversible method use condoms more consistently than women who use a reversible method. Women on ART and with an HIV-serodiscordant partner have greater odds of consistent condom use than their counterparts. PMID:26316959

  12. Potassium-Based Dual Ion Battery with Dual-Graphite Electrode.

    PubMed

    Fan, Ling; Liu, Qian; Chen, Suhua; Lin, Kairui; Xu, Zhi; Lu, Bingan

    2017-08-01

    A potassium ion battery has potential applications for large scale electric energy storage systems due to the abundance and low cost of potassium resources. Dual graphite batteries, with graphite as both anode and cathode, eliminate the use of transition metal compounds and greatly lower the overall cost. Herein, combining the merits of the potassium ion battery and dual graphite battery, a potassium-based dual ion battery with dual-graphite electrode is developed. It delivers a reversible capacity of 62 mA h g -1 and medium discharge voltage of ≈3.96 V. The intercalation/deintercalation mechanism of K + and PF 6 - into/from graphite is proposed and discussed in detail, with various characterizations to support. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Dynamical response of the Galileo Galilei on the ground rotor to test the equivalence principle: Theory, simulation, and experiment. I. The normal modes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Comandi, G.L.; Chiofalo, M.L.; Toncelli, R.

    Recent theoretical work suggests that violation of the equivalence principle might be revealed in a measurement of the fractional differential acceleration {eta} between two test bodies-of different compositions, falling in the gravitational field of a source mass--if the measurement is made to the level of {eta}{approx_equal}10{sup -13} or better. This being within the reach of ground based experiments gives them a new impetus. However, while slowly rotating torsion balances in ground laboratories are close to reaching this level, only an experiment performed in a low orbit around the Earth is likely to provide a much better accuracy. We report onmore » the progress made with the 'Galileo Galilei on the ground' (GGG) experiment, which aims to compete with torsion balances using an instrument design also capable of being converted into a much higher sensitivity space test. In the present and following articles (Part I and Part II), we demonstrate that the dynamical response of the GGG differential accelerometer set into supercritical rotation-in particular, its normal modes (Part I) and rejection of common mode effects (Part II)-can be predicted by means of a simple but effective model that embodies all the relevant physics. Analytical solutions are obtained under special limits, which provide the theoretical understanding. A simulation environment is set up, obtaining a quantitative agreement with the available experimental data on the frequencies of the normal modes and on the whirling behavior. This is a needed and reliable tool for controlling and separating perturbative effects from the expected signal, as well as for planning the optimization of the apparatus.« less

  14. Mild decentration measured by a Scheimpflug camera and its impact on visual quality following SMILE in the early learning curve.

    PubMed

    Li, Meiyan; Zhao, Jing; Miao, Huamao; Shen, Yang; Sun, Ling; Tian, Mi; Wadium, Elizabeth; Zhou, Xingtao

    2014-05-20

    To measure decentration following femtosecond laser small incision lenticule extraction (SMILE) for the correction of myopia and myopic astigmatism in the early learning curve, and to investigate its impact on visual quality. A total of 55 consecutive patients (100 eyes) who underwent the SMILE procedure were included. Decentration was measured using a Scheimpflug camera 6 months after surgery. Uncorrected and corrected distance visual acuity (UDVA, CDVA), manifest refraction, and wavefront errors were also measured. Associations between decentration and the preoperative spherical equivalent were analyzed, as well as the associations between decentration and wavefront aberrations. Regarding efficacy and safety, 40 eyes (40%) had an unchanged CDVA; 32 eyes (32%) gained one line; and 11 eyes (11%) gained two lines. Fifteen eyes (15%) lost one line of CDVA, and two eyes (2%) lost two lines. Ninety-nine of the treated eyes (99%) had a postoperative UDVA better than 1.0, and 100 eyes (100%) had a UDVA better than 0.8. The mean decentered displacement was 0.17 ± 0.09 mm. The decentered displacement of all treated eyes (100%) was within 0.50 mm; 70 eyes (70%) were within 0.20 mm; and 90 eyes (90%) were within 0.30 mm. The vertical coma showed the greatest increase in magnitude. The magnitude of horizontal decentration was found to be associated with an induced horizontal coma. This study suggests that, although mild decentration occurred in the early learning curve, good visual outcomes were achieved after the SMILE surgery. Special efforts to minimize induced vertical coma are necessary. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  15. Dual Diagnosis - Multiple Languages

    MedlinePlus

    ... National Library of Medicine Comorbidity or dual diagnosis - Opioid addiction, part 9 - English PDF Comorbidity or dual diagnosis - Opioid addiction, part 9 - español (Spanish) PDF Comorbidity or dual ...

  16. Dual Career Families.

    ERIC Educational Resources Information Center

    Farmer, Helen S.

    Home-career conflict may exist in varying degrees for both spouses in a dual-career couple. Home-career conflict exists when a dual-career wife values both homemaking and career and views some aspects of these two roles as incompatible. Home-career conflict results when a dual-career husband values his own career and that of his wife, but is…

  17. Comparison of corneal biomechanics in Sjögren's syndrome and non-Sjögren's syndrome dry eyes by Scheimpflug based device.

    PubMed

    Long, Qin; Wang, Jing-Yi; Xu, Dong; Li, Ying

    2017-01-01

    To compare the corneal biomechanics of Sjögren's syndrome (SS) and non-SS dry eyes with Corneal Visualization Scheimpflug Technology (CorVis ST). Corneal biomechanics and tear film parameters, namely the Schirmer I test value, tear film break-up time (TBUT) and corneal staining score (CSS) were detected in 34 eyes of 34 dry eye patients with SS (SSDE group) and 34 dry eye subjects without SS (NSSDE group) using CorVis ST. The differences of the above parameters between the two groups were examined, and the relationship between corneal biomechanics and tear film parameters were observed. The differences in age, sex, intraocular pressure (IOP) and central corneal thickness (CCT) were not significant between the two groups ( P >0.05). The tear film parameters had significant differences between the SSDE group and NSSDE group (all P <0.05). Patients in the SSDE group had significantly lower A1-time and HC-time, but higher DA ( P =0.01, 0.02, and 0.02, respectively) compared with the NSSDE group. In the SSDE group, DA was negatively correlated with TBUT ( rho =-0.38, P =0.03); HC-time was negatively correlated with CSS ( rho =-0.43, P =0.02). In the NSSDE group, HC-time was again negatively correlated with CSS ( rho =-0.39, P =0.02). There are differences in corneal biomechanical properties between SSDE and NSSDE. The cornea of SSDE tends to show less "stiffness", as seen by a significantly shorter A1-time and HC-time, but larger DA, compared with the cornea of NSSDE. Biomechanical parameters can be influenced by different tear film parameters in both groups.

  18. Dual-targeting siRNAs

    PubMed Central

    Tiemann, Katrin; Höhn, Britta; Ehsani, Ali; Forman, Stephen J.; Rossi, John J.; Sætrom, Pål

    2010-01-01

    We have developed an algorithm for the prediction of dual-targeting short interfering RNAs (siRNAs) in which both strands are deliberately designed to separately target different mRNA transcripts with complete complementarity. An advantage of this approach versus the use of two separate duplexes is that only two strands, as opposed to four, are competing for entry into the RNA-induced silencing complex. We chose to design our dual-targeting siRNAs as Dicer substrate 25/27mer siRNAs, since design features resembling pre-microRNAs (miRNAs) can be introduced for Dicer processing. Seven different dual-targeting siRNAs targeting genes that are potential targets in cancer therapy have been developed including Bcl2, Stat3, CCND1, BIRC5, and MYC. The dual-targeting siRNAs have been characterized for dual target knockdown in three different cell lines (HEK293, HCT116, and PC3), where they were as effective as their corresponding single-targeting siRNAs in target knockdown. The algorithm developed in this study should prove to be useful for predicting dual-targeting siRNAs in a variety of different targets and is available from http://demo1.interagon.com/DualTargeting/. PMID:20410240

  19. Lp-dual affine surface area

    NASA Astrophysics Data System (ADS)

    Wei, Wang; Binwu, He

    2008-12-01

    According to the notion of Lp-affine surface area by Lutwak, in this paper, we introduce the concept of Lp-dual affine surface area. Further, we establish the affine isoperimetric inequality and the Blaschke-Santaló inequality for Lp-dual affine surface area. Besides, the dual Brunn-Minkowski inequality for Lp-dual affine surface area is presented.

  20. Dual Motor-Cognitive Virtual Reality Training Impacts Dual-Task Performance in Freezing of Gait.

    PubMed

    Killane, Isabelle; Fearon, Conor; Newman, Louise; McDonnell, Conor; Waechter, Saskia M; Sons, Kristian; Lynch, Timothy; Reilly, Richard B

    2015-11-01

    Freezing of gait (FOG), an episodic gait disturbance characterized by the inability to generate effective stepping, occurs in more than half of Parkinson's disease patients. It is associated with both executive dysfunction and attention and becomes most evident during dual tasking (performing two tasks simultaneously). This study examined the effect of dual motor-cognitive virtual reality training on dual-task performance in FOG. Twenty community dwelling participants with Parkinson's disease (13 with FOG, 7 without FOG) participated in a pre-assessment, eight 20-minute intervention sessions, and a post-assessment. The intervention consisted of a virtual reality maze (DFKI, Germany) through which participants navigated by stepping-in-place on a balance board (Nintendo, Japan) under time pressure. This was combined with a cognitive task (Stroop test), which repeatedly divided participants' attention. The primary outcome measures were pre- and post-intervention differences in motor (stepping time, symmetry, rhythmicity) and cognitive (accuracy, reaction time) performance during single- and dual-tasks. Both assessments consisted of 1) a single cognitive task 2) a single motor task, and 3) a dual motor-cognitive task. Following the intervention, there was significant improvement in dual-task cognitive and motor parameters (stepping time and rhythmicity), dual-task effect for those with FOG and a noteworthy improvement in FOG episodes. These improvements were less significant for those without FOG. This is the first study to show benefit of a dual motor-cognitive approach on dual-task performance in FOG. Advances in such virtual reality interventions for home use could substantially improve the quality of life for patients who experience FOG.

  1. Dual leadership in a hospital practice.

    PubMed

    Thude, Bettina Ravnborg; Thomsen, Svend Erik; Stenager, Egon; Hollnagel, Erik

    2017-02-06

    Purpose Despite the practice of dual leadership in many organizations, there is relatively little research on the topic. Dual leadership means two leaders share the leadership task and are held jointly accountable for the results of the unit. To better understand how dual leadership works, this study aims to analyse three different dual leadership pairs at a Danish hospital. Furthermore, this study develops a tool to characterize dual leadership teams from each other. Design/methodology/approach This is a qualitative study using semi-structured interviews. Six leaders were interviewed to clarify how dual leadership works in a hospital context. All interviews were transcribed and coded. During coding, focus was on the nine principles found in the literature and another principle was found by looking at the themes that were generic for all six interviews. Findings Results indicate that power balance, personal relations and decision processes are important factors for creating efficient dual leaderships. The study develops a categorizing tool to use for further research or for organizations, to describe and analyse dual leaderships. Originality/value The study describes dual leadership in the hospital context and develops a categorizing tool for being able to distinguish dual leadership teams from each other. It is important to reveal if there are any indicators that can be used for optimising dual leadership teams in the health-care sector and in other organisations.

  2. Experimental Array for Generating Dual Circularly-Polarized Dual-Mode OAM Radio Beams.

    PubMed

    Bai, Xu-Dong; Liang, Xian-Ling; Sun, Yun-Tao; Hu, Peng-Cheng; Yao, Yu; Wang, Kun; Geng, Jun-Ping; Jin, Rong-Hong

    2017-01-10

    Recently, vortex beam carrying orbital angular momentum (OAM) for radio communications has attracted much attention for its potential of transmitting multiple signals simultaneously at the same frequency, which can be used to increase the channel capacity. However, most of the methods for getting multi-mode OAM radio beams are of complicated structure and very high cost. This paper provides an effective solution of generating dual circularly-polarized (CP) dual-mode OAM beams. The antenna consists of four dual-CP elements which are sequentially rotated 90 degrees in the clockwise direction. Different from all previous published research relating to OAM generation by phased arrays, the four elements are fed with the same phase for both left-hand circular polarization (LHCP) and right-hand circular polarization (RHCP). The dual-mode operation for OAM is achieved through the opposite phase differences generated for LHCP and RHCP, when the dual-CP elements are sequentially rotated in the clockwise direction. The measured results coincide well with the simulated ones, which verified the effectiveness of the proposed design.

  3. Nonword Reading: Comparing Dual-Route Cascaded and Connectionist Dual-Process Models with Human Data

    ERIC Educational Resources Information Center

    Pritchard, Stephen C.; Coltheart, Max; Palethorpe, Sallyanne; Castles, Anne

    2012-01-01

    Two prominent dual-route computational models of reading aloud are the dual-route cascaded (DRC) model, and the connectionist dual-process plus (CDP+) model. While sharing similarly designed lexical routes, the two models differ greatly in their respective nonlexical route architecture, such that they often differ on nonword pronunciation. Neither…

  4. The Dual Language Program Planner: A Guide for Designing and Implementing Dual Language Programs.

    ERIC Educational Resources Information Center

    Howard, Elizabeth R.; Olague, Natalie; Rogers, David

    This guide offers a framework to facilitate the planning process for dual language programs, assuming at least a basic working knowledge of the central characteristics and essential features of dual language models. It provides an overview of the various models that serve linguistically diverse student populations, defining the term dual language…

  5. New Fukui, dual and hyper-dual kernels as bond reactivity descriptors.

    PubMed

    Franco-Pérez, Marco; Polanco-Ramírez, Carlos-A; Ayers, Paul W; Gázquez, José L; Vela, Alberto

    2017-06-21

    We define three new linear response indices with promising applications for bond reactivity using the mathematical framework of τ-CRT (finite temperature chemical reactivity theory). The τ-Fukui kernel is defined as the ratio between the fluctuations of the average electron density at two different points in the space and the fluctuations in the average electron number and is designed to integrate to the finite-temperature definition of the electronic Fukui function. When this kernel is condensed, it can be interpreted as a site-reactivity descriptor of the boundary region between two atoms. The τ-dual kernel corresponds to the first order response of the Fukui kernel and is designed to integrate to the finite temperature definition of the dual descriptor; it indicates the ambiphilic reactivity of a specific bond and enriches the traditional dual descriptor by allowing one to distinguish between the electron-accepting and electron-donating processes. Finally, the τ-hyper dual kernel is defined as the second-order derivative of the Fukui kernel and is proposed as a measure of the strength of ambiphilic bonding interactions. Although these quantities have never been proposed, our results for the τ-Fukui kernel and for τ-dual kernel can be derived in zero-temperature formulation of the chemical reactivity theory with, among other things, the widely-used parabolic interpolation model.

  6. Modular synthesis of a dual metal-dual semiconductor nano-heterostructure

    DOE PAGES

    Amirav, Lilac; Oba, Fadekemi; Aloni, Shaul; ...

    2015-04-29

    Reported is the design and modular synthesis of a dual metal-dual semiconductor heterostructure with control over the dimensions and placement of its individual components. Analogous to molecular synthesis, colloidal synthesis is now evolving into a series of sequential synthetic procedures with separately optimized steps. Here we detail the challenges and parameters that must be considered when assembling such a multicomponent nanoparticle, and their solutions.

  7. Dual coil ignition system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huberts, Garlan J.; Qu, Qiuping; Czekala, Michael Damian

    2017-03-28

    A dual coil ignition system is provided. The dual coil ignition system includes a first inductive ignition coil including a first primary winding and a first secondary winding, and a second inductive ignition coil including a second primary winding and a second secondary winding, the second secondary winding connected in series to the first secondary winding. The dual coil ignition system further includes a diode network including a first diode and a second diode connected between the first secondary winding and the second secondary winding.

  8. Dual-Modulation, Dual-Wavelength, Optical Polarimetry System for Glucose Monitoring

    DTIC Science & Technology

    2016-08-26

    dual-wavelength, optical polarimetry system for glucose monitoring 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER N/A 6. AUTHOR(S) 5d...JBO.21.8.087001] 14. ABSTRACT A dual modulation optical polarimetry system utilizing both laser intensity and polarization modulation was designed...varying birefringence, which is one of the major limitations to the realization of polarimetry for glucose monitoring in the eye. The high-speed less

  9. Effects of dual tasks and dual-task training on postural stability: a systematic review and meta-analysis

    PubMed Central

    Ghai, Shashank; Ghai, Ishan; Effenberg, Alfred O

    2017-01-01

    The use of dual-task training paradigm to enhance postural stability in patients with balance impairments is an emerging area of interest. The differential effects of dual tasks and dual-task training on postural stability still remain unclear. A systematic review and meta-analysis were conducted to analyze the effects of dual task and training application on static and dynamic postural stability among various population groups. Systematic identification of published literature was performed adhering to Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines, from inception until June 2016, on the online databases Scopus, PEDro, MEDLINE, EMBASE, and SportDiscus. Experimental studies analyzing the effects of dual task and dual-task training on postural stability were extracted, critically appraised using PEDro scale, and then summarized according to modified PEDro level of evidence. Of 1,284 records, 42 studies involving 1,480 participants met the review’s inclusion criteria. Of the studies evaluating the effects of dual-task training on postural stability, 87.5% of the studies reported significant enhancements, whereas 30% of the studies evaluating acute effects of dual tasks on posture reported significant enhancements, 50% reported significant decrements, and 20% reported no effects. Meta-analysis of the pooled studies revealed moderate but significant enhancements of dual-task training in elderly participants (95% CI: 1.16–2.10) and in patients suffering from chronic stroke (−0.22 to 0.86). The adverse effects of complexity of dual tasks on postural stability were also revealed among patients with multiple sclerosis (−0.74 to 0.05). The review also discusses the significance of verbalization in a dual-task setting for increasing cognitive–motor interference. Clinical implications are discussed with respect to practical applications in rehabilitation settings. PMID:28356727

  10. Effects of dual tasks and dual-task training on postural stability: a systematic review and meta-analysis.

    PubMed

    Ghai, Shashank; Ghai, Ishan; Effenberg, Alfred O

    2017-01-01

    The use of dual-task training paradigm to enhance postural stability in patients with balance impairments is an emerging area of interest. The differential effects of dual tasks and dual-task training on postural stability still remain unclear. A systematic review and meta-analysis were conducted to analyze the effects of dual task and training application on static and dynamic postural stability among various population groups. Systematic identification of published literature was performed adhering to Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines, from inception until June 2016, on the online databases Scopus, PEDro, MEDLINE, EMBASE, and SportDiscus. Experimental studies analyzing the effects of dual task and dual-task training on postural stability were extracted, critically appraised using PEDro scale, and then summarized according to modified PEDro level of evidence. Of 1,284 records, 42 studies involving 1,480 participants met the review's inclusion criteria. Of the studies evaluating the effects of dual-task training on postural stability, 87.5% of the studies reported significant enhancements, whereas 30% of the studies evaluating acute effects of dual tasks on posture reported significant enhancements, 50% reported significant decrements, and 20% reported no effects. Meta-analysis of the pooled studies revealed moderate but significant enhancements of dual-task training in elderly participants (95% CI: 1.16-2.10) and in patients suffering from chronic stroke (-0.22 to 0.86). The adverse effects of complexity of dual tasks on postural stability were also revealed among patients with multiple sclerosis (-0.74 to 0.05). The review also discusses the significance of verbalization in a dual-task setting for increasing cognitive-motor interference. Clinical implications are discussed with respect to practical applications in rehabilitation settings.

  11. Dynamic dual-tracer PET reconstruction.

    PubMed

    Gao, Fei; Liu, Huafeng; Jian, Yiqiang; Shi, Pengcheng

    2009-01-01

    Although of important medical implications, simultaneous dual-tracer positron emission tomography reconstruction remains a challenging problem, primarily because the photon measurements from dual tracers are overlapped. In this paper, we propose a simultaneous dynamic dual-tracer reconstruction of tissue activity maps based on guidance from tracer kinetics. The dual-tracer reconstruction problem is formulated in a state-space representation, where parallel compartment models serve as continuous-time system equation describing the tracer kinetic processes of dual tracers, and the imaging data is expressed as discrete sampling of the system states in measurement equation. The image reconstruction problem has therefore become a state estimation problem in a continuous-discrete hybrid paradigm, and H infinity filtering is adopted as the estimation strategy. As H infinity filtering makes no assumptions on the system and measurement statistics, robust reconstruction results can be obtained for the dual-tracer PET imaging system where the statistical properties of measurement data and system uncertainty are not available a priori, even when there are disturbances in the kinetic parameters. Experimental results on digital phantoms, Monte Carlo simulations and physical phantoms have demonstrated the superior performance.

  12. Cognitive and motor dual task gait training improve dual task gait performance after stroke - A randomized controlled pilot trial.

    PubMed

    Liu, Yan-Ci; Yang, Yea-Ru; Tsai, Yun-An; Wang, Ray-Yau

    2017-06-22

    This study investigated effects of cognitive and motor dual task gait training on dual task gait performance in stroke. Participants (n = 28) were randomly assigned to cognitive dual task gait training (CDTT), motor dual task gait training (MDTT), or conventional physical therapy (CPT) group. Participants in CDTT or MDTT group practiced the cognitive or motor tasks respectively during walking. Participants in CPT group received strengthening, balance, and gait training. The intervention was 30 min/session, 3 sessions/week for 4 weeks. Three test conditions to evaluate the training effects were single walking, walking while performing cognitive task (serial subtraction), and walking while performing motor task (tray-carrying). Parameters included gait speed, dual task cost of gait speed (DTC-speed), cadence, stride time, and stride length. After CDTT, cognitive-motor dual task gait performance (stride length and DTC-speed) was improved (p = 0.021; p = 0.015). After MDTT, motor dual task gait performance (gait speed, stride length, and DTC-speed) was improved (p = 0.008; p = 0.008; p = 0.008 respectively). It seems that CDTT improved cognitive dual task gait performance and MDTT improved motor dual task gait performance although such improvements did not reach significant group difference. Therefore, different types of dual task gait training can be adopted to enhance different dual task gait performance in stroke.

  13. Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT.

    PubMed

    Pelgrim, Gert Jan; van Hamersvelt, Robbert W; Willemink, Martin J; Schmidt, Bernhard T; Flohr, Thomas; Schilham, Arnold; Milles, Julien; Oudkerk, Matthijs; Leiner, Tim; Vliegenthart, Rozemarijn

    2017-09-01

    To determine the accuracy of iodine quantification with dual energy computed tomography (DECT) in two high-end CT systems with different spectral imaging techniques. Five tubes with different iodine concentrations (0, 5, 10, 15, 20 mg/ml) were analysed in an anthropomorphic thoracic phantom. Adding two phantom rings simulated increased patient size. For third-generation dual source CT (DSCT), tube voltage combinations of 150Sn and 70, 80, 90, 100 kVp were analysed. For dual layer CT (DLCT), 120 and 140 kVp were used. Scans were repeated three times. Median normalized values and interquartile ranges (IQRs) were calculated for all kVp settings and phantom sizes. Correlation between measured and known iodine concentrations was excellent for both systems (R = 0.999-1.000, p < 0.0001). For DSCT, median measurement errors ranged from -0.5% (IQR -2.0, 2.0%) at 150Sn/70 kVp and -2.3% (IQR -4.0, -0.1%) at 150Sn/80 kVp to -4.0% (IQR -6.0, -2.8%) at 150Sn/90 kVp. For DLCT, median measurement errors ranged from -3.3% (IQR -4.9, -1.5%) at 140 kVp to -4.6% (IQR -6.0, -3.6%) at 120 kVp. Larger phantom sizes increased variability of iodine measurements (p < 0.05). Iodine concentration can be accurately quantified with state-of-the-art DECT systems from two vendors. The lowest absolute errors were found for DSCT using the 150Sn/70 kVp or 150Sn/80 kVp combinations, which was slightly more accurate than 140 kVp in DLCT. • High-end CT scanners allow accurate iodine quantification using different DECT techniques. • Lowest measurement error was found in scans with largest photon energy separation. • Dual-source CT quantified iodine slightly more accurately than dual layer CT.

  14. Dual-use technology programs

    NASA Astrophysics Data System (ADS)

    Johns, Lionel S.

    1994-10-01

    The paper presents the Clinton Administration's commitment to American industrial competitiveness through a strategic focus on research and development and to dual-use technologies in particular. Working in partnership with industry, the dual-use approach is essential for giving our armed forces the world's best, most technically advanced military equipment at affordable cost. The President has set a goal of shifting from a dominant role for military technologies in our Federal R&D investments to a roughly equal balance between military on the one hand and civilian and dual-use on the other. We have already made significant progress toward this goal.

  15. Comparison of Keratometry Obtained by a Swept Source OCT-Based Biometer with a Standard Optical Biometer and Scheimpflug Imaging.

    PubMed

    Asena, Leyla; Akman, Ahmet; Güngör, Sirel Gür; Dursun Altınörs, Dilek

    2018-04-09

    To assess agreement of a swept source-optical coherence tomography (SS-OCT) based Biometer with a standard IOLMaster device and Scheimpflug Imaging (SI) to acquire keratometric measurements in cataract patients. In this prospective comparative study, 101 eyes of 101 cataract surgery candidates, aged 24-81 years, were sequentially examined using three devices. Keratometry values at the flat (K1) and steep (K2) axis, mean corneal power (Km) and magnitude of corneal astigmatism as well as J0 and J45 vectoral components of astigmatism obtained with the SS-OCT based biometer (IOLMaster 700) were compared with those obtained with the IOLMaster 500 and SI. The agreement between measurements was evaluated by the Bland-Altman method, intraclass correlation coefficients (ICCs) and repeated-measures analysis of variance. Mean K1 values from the three devices were similar (p = 0.09). Mean K2 and Km values of IOLMaster 700 were higher than SI and lower than IOLMaster 500 (p = 0.04 for K2 and p = 0.02 for Km). There was a strong correlation between K1, K2, Km and magnitude of astigmatism obtained with all devices (r ≥ 0.80 and p < 0.01). The 95% limits of agreement (LoA) width for each keratometric value were highest for the comparison between IOLMaster 500 and SI and lowest for the comparison between IOLMaster 700 and 500. The mean differences (width of 95% LoA) for J0 and J45 vectoral components were 0.005 (2.19) and 0.12 (2.92) for the measurements obtained by IOLMaster 700 vs IOLMaster 500 and 0.06 (1.79) and 0.02 (1.58) for the measurements obtained by IOLMaster 700 vs SI, respectively. With ICCs close to 1, the agreement between all devices was excellent for keratometric measurements. Mean K2, Km and astigmatism measurements from IOLMaster 700 were lower than IOLMaster 500 and higher than SI. However, the differences were quite small and are not expected to affect the final IOL power.

  16. Dual Enrollment Academy Programs

    ERIC Educational Resources Information Center

    Gonzalez, Nicolas; Chavez, Guadalupe

    2009-01-01

    Dual Enrollment Engineering (DEEA) and Medical Science (DEMSA) Academies are two-year dual enrollment programs for high school students. Students explore engineering and medical careers through college coursework. Students prepare for higher education in engineering and medical fields while completing associate degrees in biology or engineering…

  17. 46 CFR 120.324 - Dual voltage generators.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual voltage generators. 120.324 Section 120.324... INSTALLATION Power Sources and Distribution Systems § 120.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual voltage...

  18. Coping in Dual-Employed Families: Spousal Differences.

    ERIC Educational Resources Information Center

    Skinner, Denise A.; McCubbin, Hamilton I.

    The Dual Employed Coping Scales (DECS) were developed to measure coping behaviors and patterns of dual-employed families. The original DECS (58 self-report items) was administered to a sample of 60 individuals in dual-employed families. In another study, in which 69 dual-employed couples completed the DECS and the Family Adaptability and Cohesion…

  19. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at the...

  20. Dual Relationships in Counseling.

    ERIC Educational Resources Information Center

    Herlihy, Barbara; Corey, Gerald

    Issues involving dual relationships in counseling are discussed in this monograph. Dual relationships occur when counselors have another, significantly different, relationship with one of their clients, students, or supervisees. This monograph is intended to be a resource that reflects the current thinking of the counseling profession and that…

  1. Dual-Credit in Kentucky

    ERIC Educational Resources Information Center

    Stephenson, Lisa G.

    2013-01-01

    Credit-based transition programs provide high school students with opportunities to jump start their college education. The Kentucky Community and Technical College System (KCTCS) offers college credit through dual-credit programs. While KCTCS dual-credit offerings have been successful in helping high school students start their college education…

  2. Dual nozzle aerodynamic and cooling analysis study

    NASA Technical Reports Server (NTRS)

    Meagher, G. M.

    1981-01-01

    Analytical models to predict performance and operating characteristics of dual nozzle concepts were developed and improved. Aerodynamic models are available to define flow characteristics and bleed requirements for both the dual throat and dual expander concepts. Advanced analytical techniques were utilized to provide quantitative estimates of the bleed flow, boundary layer, and shock effects within dual nozzle engines. Thermal analyses were performed to define cooling requirements for baseline configurations, and special studies of unique dual nozzle cooling problems defined feasible means of achieving adequate cooling.

  3. Dual-Doppler Feasibility Study

    NASA Technical Reports Server (NTRS)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  4. Dual agency, dual relationships, boundary crossings, and associated boundary violations: a survey of military and civilian psychiatrists.

    PubMed

    Hines, A H; Ader, D N; Chang, A S; Rundell, J R

    1998-12-01

    We hypothesized that psychiatrists with high dual-agency potential (military and health maintenance organization [HMO] psychiatrists) were more likely than non-HMO civilian psychiatrists to engage in dual relationships, report pressures to do so, participate in other general boundary-crossing activities, and report associated counter-therapeutic outcomes (boundary violations). Ninety military and 191 demographically matched civilian psychiatrists reported the number of boundary-crossing activities (including dual relationships) and associated counter-therapeutic outcomes in the preceding year with adult patients. Military and HMO psychiatrists reported greater external pressures than non-HMO civilian psychiatrists to engage in dual relationships; however, all three groups were similar in their reported numbers of dual relationships. The reported boundary-crossing activities and dual relationships studied here are not necessarily associated with reported boundary violations. The relative risk of a particular boundary crossing associating with harm to a patient likely depends on the therapeutic context and should be determined on a case-by-case basis.

  5. Dual-modality imaging

    NASA Astrophysics Data System (ADS)

    Hasegawa, Bruce; Tang, H. Roger; Da Silva, Angela J.; Wong, Kenneth H.; Iwata, Koji; Wu, Max C.

    2001-09-01

    In comparison to conventional medical imaging techniques, dual-modality imaging offers the advantage of correlating anatomical information from X-ray computed tomography (CT) with functional measurements from single-photon emission computed tomography (SPECT) or with positron emission tomography (PET). The combined X-ray/radionuclide images from dual-modality imaging can help the clinician to differentiate disease from normal uptake of radiopharmaceuticals, and to improve diagnosis and staging of disease. In addition, phantom and animal studies have demonstrated that a priori structural information from CT can be used to improve quantification of tissue uptake and organ function by correcting the radionuclide data for errors due to photon attenuation, partial volume effects, scatter radiation, and other physical effects. Dual-modality imaging therefore is emerging as a method of improving the visual quality and the quantitative accuracy of radionuclide imaging for diagnosis of patients with cancer and heart disease.

  6. Dual-polarization and dual-mode orbital angular momentum radio vortex beam generated by using reflective metasurface

    NASA Astrophysics Data System (ADS)

    Yu, Shixing; Li, Long; Shi, Guangming

    2016-08-01

    A metasurface, which is composed of printed cross-dipole elements with different arm lengths, is designed, fabricated, and experimentally demonstrated to generate orbital angular momentum (OAM) vortex waves of dual polarizations and dual modes in the radio frequency domain simultaneously. The prototype of a practical metasurface is fabricated and measured to validate the results of theoretical analysis and design at 5.8 GHz. Numerical and experimental results verify that vortex waves with dual OAM modes and dual polarizations can be flexibly generated by using a reflective metasurface. The proposed method paves a way to generate diverse OAM vortex waves for radio frequency and microwave wireless communication applications.

  7. Effect of Long-term Care Use on Medicare and Medicaid Expenditures for Dual Eligible and Non-dual Eligible Elderly Beneficiaries

    PubMed Central

    Kane, Robert L; Wysocki, Andrea; Parashuram, Shriram; Shippee, Tetyana; Lum, Terry

    2013-01-01

    Background: Dual eligible Medicare and Medicaid beneficiaries consume disproportionate shares of both programs. Objectives: To compare Medicare and Medicaid expenditures of elderly dual eligible beneficiaries with non-dual eligible beneficiaries based on their long-term care (LTC) use. Research Design: Secondary analysis of linked MAX and Medicare data in seven states. Subjects: Dual eligible adults (65+) receiving LTC in institutions, in the community, or not at all; and Medicare non-dual eligibles. Measures: Medicaid acute medical and LTC expenditures per beneficiary year, Medicare expenditures. Results: Among dual eligibles and non-dual eligibles, the average number of diseases and case mix scores are higher for LTC users. Adjusting for case mix virtually eliminates the difference for medical costs, but not for LTC expenditures. Adjusting for LTC status reduces the difference in LTC costs, but increases the difference in medical costs. Conclusions: Efforts to control costs for dual eligibles should target those in LTC while better coordinating medical and LTC expenditures. PMID:24753971

  8. Galileo and the Movies

    NASA Astrophysics Data System (ADS)

    Olivotto, Cristina; Testa, Antonella

    2010-12-01

    We analyze the character of Galileo Galilei (1564-1642), one of the most famous scientists of all time, as portrayed in three significant movies: Luigi Maggi's Galileo Galilei (1909), Liliana Cavani's Galileo (1968), and Joseph Losey's Galileo (1975), the last one of which was based upon Bertolt Brecht's drama, Das Leben des Galilei (1947). We investigate the relationships between the main characteristics of these fictional Galileos and the most important twentieth-century Galilean historiographic models. We also analyze the veracity of the plots of these three movies and the role that historical and scientific consultants played in producing them. We conclude that connections between these three movies and Galilean historiographic models are far from evident, that other factors deeply influenced the representation of Galileo on the screen.

  9. Dual Career Couples in Academia, International Mobility and Dual Career Services in Europe

    ERIC Educational Resources Information Center

    Tzanakou, Charikleia

    2017-01-01

    The number of dual career couples in academia is growing due to the increasing proportion of women with a doctoral degree and the greater propensity of women to choose another academic as their partner. At the same time, international mobility is required for career advancement in academia, creating challenges for dual career couples where both…

  10. Dual-use review policies of biomedical research journals.

    PubMed

    Resnik, David B; Barner, Dionne D; Dinse, Gregg E

    2011-03-01

    To address biosecurity issues, government agencies, academic institutions, and professional societies have developed policies concerning the publication of "dual-use" biomedical research-that is, research that could be readily applied to cause significant harm to the public, the environment, or national security. We conducted an e-mail survey of life science journals to determine the percentage that have a dual-use policy. Of the 155 journals that responded to our survey (response rate 39%), only 7.7% stated that they had a written dual-use policy and only 5.8% said they had experience reviewing dual-use research in the past 5 years. Among the potential predictors we investigated, the one most highly associated with a journal having a written dual-use policy was membership in the Nature Publishing Group (positive association). When considered individually, both previous experience with reviewing dual-use research and the journal's impact factor appeared to be positively associated with having a written dual-use policy, but only the former remained significant after adjusting for publishing group. Although preventing the misuse of scientific research for terrorist or criminal purposes is an important concern, few biomedical journals have dual-use review policies. Journals that are likely to review research that raises potential dual-use concerns should consider developing dual-use policies.

  11. Dual-Energy CT: New Horizon in Medical Imaging

    PubMed Central

    Goo, Jin Mo

    2017-01-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector. PMID:28670151

  12. Dual education and industrial cooperation in electrical engineering

    NASA Astrophysics Data System (ADS)

    Váradiné Szarka, A.

    2016-11-01

    Dual education in higher education is a new system in Hungary introduced by Mercedes Benz with cooperation of Kecskemet College. In the new system companies support certain number of students and provide them strong practical education in their field. Students applying successfully for dual education study together with non-dual students at the university, so they go through the same university courses as their non-dual colleagues, but while non-dual students’ academic year includes 2×14 weeks active semester and 2×6 weeks exam session, all over 40 weeks, dual students have 48 working weeks including study at the university and practicing at the company. The main question of the success which one is the most effective model to be applied. This paper summarises 2 models of dual education with their advantages and disadvantages and also it presents practical realization at the University of Debrecen with special attention to measurement and instrumentation. Dual education in BSc level electrical engineering course cooperates with 6 multinational companies of the region in four specialization. Dual education also has great impact to the modernisation of engineering education. Detailed study of dual education in field of instrumentation and measurement is provided in the paper.

  13. Dual-domain point diffraction interferometer

    DOEpatents

    Naulleau, Patrick P.; Goldberg, Kenneth Alan

    2000-01-01

    A hybrid spatial/temporal-domain point diffraction interferometer (referred to as the dual-domain PS/PDI) that is capable of suppressing the scattered-reference-light noise that hinders the conventional PS/PDI is provided. The dual-domain PS/PDI combines the separate noise-suppression capabilities of the widely-used phase-shifting and Fourier-transform fringe pattern analysis methods. The dual-domain PS/PDI relies on both a more restrictive implementation of the image plane PS/PDI mask and a new analysis method to be applied to the interferograms generated and recorded by the modified PS/PDI. The more restrictive PS/PDI mask guarantees the elimination of spatial-frequency crosstalk between the signal and the scattered-light noise arising from scattered-reference-light interfering with the test beam. The new dual-domain analysis method is then used to eliminate scattered-light noise arising from both the scattered-reference-light interfering with the test beam and the scattered-reference-light interfering with the "true" pinhole-diffracted reference light. The dual-domain analysis method has also been demonstrated to provide performance enhancement when using the non-optimized standard PS/PDI design. The dual-domain PS/PDI is essentially a three-tiered filtering system composed of lowpass spatial-filtering the test-beam electric field using the more restrictive PS/PDI mask, bandpass spatial-filtering the individual interferogram irradiance frames making up the phase-shifting series, and bandpass temporal-filtering the phase-shifting series as a whole.

  14. Dual symmetry in a generalized Maxwell theory

    NASA Astrophysics Data System (ADS)

    Brandt, F. T.; Frenkel, J.; McKeon, D. G. C.

    2016-09-01

    We examine Podolsky’s electrodynamics, which is non-invariant under the usual duality transformation. We deduce a generalization of Hodge’s star duality, which leads to a dual gauge field and restores to a certain extent the dual symmetry. The model becomes fully dual symmetric asymptotically, when it reduces to the Maxwell theory. We argue that this strict dual symmetry directly implies the existence of the basic invariants of the electromagnetic fields.

  15. Dual-Use Review Policies of Biomedical Research Journals

    PubMed Central

    Barner, Dionne D.; Dinse, Gregg E.

    2011-01-01

    To address biosecurity issues, government agencies, academic institutions, and professional societies have developed policies concerning the publication of “dual-use” biomedical research—that is, research that could be readily applied to cause significant harm to the public, the environment, or national security. We conducted an e-mail survey of life science journals to determine the percentage that have a dual-use policy. Of the 155 journals that responded to our survey (response rate 39%), only 7.7% stated that they had a written dual-use policy and only 5.8% said they had experience reviewing dual-use research in the past 5 years. Among the potential predictors we investigated, the one most highly associated with a journal having a written dual-use policy was membership in the Nature Publishing Group (positive association). When considered individually, both previous experience with reviewing dual-use research and the journal's impact factor appeared to be positively associated with having a written dual-use policy, but only the former remained significant after adjusting for publishing group. Although preventing the misuse of scientific research for terrorist or criminal purposes is an important concern, few biomedical journals have dual-use review policies. Journals that are likely to review research that raises potential dual-use concerns should consider developing dual-use policies. PMID:21395429

  16. Running at Double Pace: Women in Dual-Profession Marriages.

    ERIC Educational Resources Information Center

    Arfken, Deborah Elwell

    Although the problems facing dual-profession couples are almost universally acknowledged, studies on dual-profession couples have only recently emerged from those on dual-worker or dual-career families. To explore the perceptions that women in dual-profession marriages have of their roles, conflicts, and coping strategies, focus group interviews…

  17. An innovative strategy for dual inhibitor design and its application in dual inhibition of human thymidylate synthase and dihydrofolate reductase enzymes.

    PubMed

    Arooj, Mahreen; Sakkiah, Sugunadevi; Cao, Guang ping; Lee, Keun Woo

    2013-01-01

    Due to the diligence of inherent redundancy and robustness in many biological networks and pathways, multitarget inhibitors present a new prospect in the pharmaceutical industry for treatment of complex diseases. Nevertheless, to design multitarget inhibitors is concurrently a great challenge for medicinal chemists. We have developed a novel computational approach by integrating the affinity predictions from structure-based virtual screening with dual ligand-based pharmacophore to discover potential dual inhibitors of human Thymidylate synthase (hTS) and human dihydrofolate reductase (hDHFR). These are the key enzymes in folate metabolic pathway that is necessary for the biosynthesis of RNA, DNA, and protein. Their inhibition has found clinical utility as antitumor, antimicrobial, and antiprotozoal agents. A druglike database was utilized to perform dual-target docking studies. Hits identified through docking experiments were mapped over a dual pharmacophore which was developed from experimentally known dual inhibitors of hTS and hDHFR. Pharmacophore mapping procedure helped us in eliminating the compounds which do not possess basic chemical features necessary for dual inhibition. Finally, three structurally diverse hit compounds that showed key interactions at both active sites, mapped well upon the dual pharmacophore, and exhibited lowest binding energies were regarded as possible dual inhibitors of hTS and hDHFR. Furthermore, optimization studies were performed for final dual hit compound and eight optimized dual hits demonstrating excellent binding features at target systems were also regarded as possible dual inhibitors of hTS and hDHFR. In general, the strategy used in the current study could be a promising computational approach and may be generally applicable to other dual target drug designs.

  18. An Innovative Strategy for Dual Inhibitor Design and Its Application in Dual Inhibition of Human Thymidylate Synthase and Dihydrofolate Reductase Enzymes

    PubMed Central

    Arooj, Mahreen; Sakkiah, Sugunadevi; Cao, Guang ping; Lee, Keun Woo

    2013-01-01

    Due to the diligence of inherent redundancy and robustness in many biological networks and pathways, multitarget inhibitors present a new prospect in the pharmaceutical industry for treatment of complex diseases. Nevertheless, to design multitarget inhibitors is concurrently a great challenge for medicinal chemists. We have developed a novel computational approach by integrating the affinity predictions from structure-based virtual screening with dual ligand-based pharmacophore to discover potential dual inhibitors of human Thymidylate synthase (hTS) and human dihydrofolate reductase (hDHFR). These are the key enzymes in folate metabolic pathway that is necessary for the biosynthesis of RNA, DNA, and protein. Their inhibition has found clinical utility as antitumor, antimicrobial, and antiprotozoal agents. A druglike database was utilized to perform dual-target docking studies. Hits identified through docking experiments were mapped over a dual pharmacophore which was developed from experimentally known dual inhibitors of hTS and hDHFR. Pharmacophore mapping procedure helped us in eliminating the compounds which do not possess basic chemical features necessary for dual inhibition. Finally, three structurally diverse hit compounds that showed key interactions at both active sites, mapped well upon the dual pharmacophore, and exhibited lowest binding energies were regarded as possible dual inhibitors of hTS and hDHFR. Furthermore, optimization studies were performed for final dual hit compound and eight optimized dual hits demonstrating excellent binding features at target systems were also regarded as possible dual inhibitors of hTS and hDHFR. In general, the strategy used in the current study could be a promising computational approach and may be generally applicable to other dual target drug designs. PMID:23577115

  19. Performance Enhancements Under Dual-task Conditions

    NASA Technical Reports Server (NTRS)

    Kramer, A. F.; Wickens, C. D.; Donchin, E.

    1984-01-01

    Research on dual-task performance has been concerned with delineating the antecedent conditions which lead to dual-task decrements. Capacity models of attention, which propose that a hypothetical resource structure underlies performance, have been employed as predictive devices. These models predict that tasks which require different processing resources can be more successfully time shared than tasks which require common resources. The conditions under which such dual-task integrality can be fostered were assessed in a study in which three factors likely to influence the integrality between tasks were manipulated: inter-task redundancy, the physical proximity of tasks and the task relevant objects. Twelve subjects participated in three experimental sessions in which they performed both single and dual-tasks. The primary task was a pursuit step tracking task. The secondary tasks required the discrimination between different intensities or different spatial positions of a stimulus. The results are discussed in terms of a model of dual-task integrality.

  20. Dual-fuel, dual-mode rocket engine

    NASA Technical Reports Server (NTRS)

    Martin, James A. (Inventor)

    1989-01-01

    The invention relates to a dual fuel, dual mode rocket engine designed to improve the performance of earth-to-orbit vehicles. For any vehicle that operates from the earth's surface to earth orbit, it is advantageous to use two different fuels during its ascent. A high density impulse fuel, such as kerosene, is most efficient during the first half of the trajectory. A high specific impulse fuel, such as hydrogen, is most efficient during the second half of the trajectory. The invention allows both fuels to be used with a single rocket engine. It does so by adding a minimum number of state-of-the-art components to baseline single made rocket engines, and is therefore relatively easy to develop for near term applications. The novelty of this invention resides in the mixing of fuels before exhaust nozzle cooling. This allows all of the engine fuel to cool the exhaust nozzle, and allows the ratio of fuels used throughout the flight depend solely on performance requirements, not cooling requirements.

  1. Dual-Mode Combustor

    NASA Technical Reports Server (NTRS)

    Trefny, Charles J (Inventor); Dippold, Vance F (Inventor)

    2013-01-01

    A new dual-mode ramjet combustor used for operation over a wide flight Mach number range is described. Subsonic combustion mode is usable to lower flight Mach numbers than current dual-mode scramjets. High speed mode is characterized by supersonic combustion in a free-jet that traverses the subsonic combustion chamber to a variable nozzle throat. Although a variable combustor exit aperture is required, the need for fuel staging to accommodate the combustion process is eliminated. Local heating from shock-boundary-layer interactions on combustor walls is also eliminated.

  2. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Dual-voltage generators. 129.326 Section 129.326 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage...

  3. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Dual-voltage generators. 129.326 Section 129.326 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage...

  4. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Dual-voltage generators. 129.326 Section 129.326 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage...

  5. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Dual-voltage generators. 129.326 Section 129.326 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage...

  6. [Dual pathology].

    PubMed

    Rougier, A

    2008-05-01

    Dual pathology is defined as the association of two potentially epileptogenic lesions, hippocampal (sclerosis, neuronal loss) and extrahippocampal (temporal or extratemporal). Epileptic activity may be generated by either lesion and the relative importance of every lesion's epileptogenicity conditions the surgical strategy adopted. Most frequently associated with hippocampal sclerosis are cortical dysplasias. The common physiopathology of the two lesions is not clearly established. Extrahippocampal lesions may be undetectable on MRI (microdysgenesis, for example) and ictal discharge patterns may vary among dual pathology patients. The surgical strategy depends on the location of the extrahippocampal lesion and its relative role in seizure generation; however, reported surgical results suggest that simultaneous resection of mesial temporal structures along with the extrahippocampal lesion should be performed.

  7. Dual Coding and Bilingual Memory.

    ERIC Educational Resources Information Center

    Paivio, Allan; Lambert, Wallace

    1981-01-01

    Describes study which tested a dual coding approach to bilingual memory using tasks that permit comparison of the effects of bilingual encoding with verbal-nonverbal dual encoding items. Results provide strong support for a version of the independent or separate stories view of bilingual memory. (Author/BK)

  8. Switchable dual-wavelength single-longitudinal-mode erbium fiber laser utilizing a dual-ring scheme with a saturable absorber

    NASA Astrophysics Data System (ADS)

    Yang, Zi-Qing; Huang, Tzu-Jung; Chang, Yao-Jen; Yeh, Chien-Hung; Chow, Chi-Wai; Chen, Jing-Heng; Chen, Kun-Huang

    2018-06-01

    In this work, we propose and demonstrate a switchable dual-wavelength erbium-doped fiber (EDF) ring laser with stable single-longitudinal-mode (SLM) output. Here, a dual-ring (DR) structure with an unpumped EDF of 2 m is designed to achieve SLM oscillation. Five fiber Bragg gratings (FBGs) are applied in the laser cavity serving as the reflective element to generate different dual-wavelength outputs. In the measurement, six sets of generated dual-wavelengths with various mode-spacing (Δλ) can be achieved via the five FBGs. Additionally, the stability performance of the proposed EDF DR laser is also demonstrated.

  9. Unraveling Executive Functioning in Dual Diagnosis.

    PubMed

    Duijkers, Judith C L M; Vissers, Constance Th W M; Egger, Jos I M

    2016-01-01

    In mental health, the term dual-diagnosis is used for the co-occurrence of Substance Use Disorder (SUD) with another mental disorder. These co-occurring disorders can have a shared cause, and can cause/intensify each other's expression. Forming a threat to health and society, dual-diagnosis is associated with relapses in addiction-related behavior and a destructive lifestyle. This is due to a persistent failure to control impulses and the maintaining of inadequate self-regulatory behavior in daily life. Thus, several aspects of executive functioning like inhibitory, shifting and updating processes seem impaired in dual-diagnosis. Executive (dys-)function is currently even seen as a shared underlying key component of most mental disorders. However, the number of studies on diverse aspects of executive functioning in dual-diagnosis is limited. In the present review, a systematic overview of various aspects of executive functioning in dual-diagnosis is presented, striving for a prototypical profile of patients with dual-diagnosis. Looking at empirical results, inhibitory and shifting processes appear to be impaired for SUD combined with schizophrenia, bipolar disorder or cluster B personality disorders. Studies involving updating process tasks for dual-diagnosis were limited. More research that zooms in to the full diversity of these executive functions is needed in order to strengthen these findings. Detailed insight in the profile of strengths and weaknesses that underlies one's behavior and is related to diagnostic classifications, can lead to tailor-made assessment and indications for treatment, pointing out which aspects need attention and/or training in one's self-regulative abilities.

  10. Data sharing and dual-use issues.

    PubMed

    Bezuidenhout, Louise

    2013-03-01

    The concept of dual-use encapsulates the potential for well-intentioned, beneficial scientific research to also be misused by a third party for malicious ends. The concept of dual-use challenges scientists to look beyond the immediate outcomes of their research and to develop an awareness of possible future (mis)uses of scientific research. Since 2001 much attention has been paid to the possible need to regulate the dual-use potential of the life sciences. Regulation initiatives fall under two broad categories-those that develop the ethical education of scientists and foster an awareness and responsibility of dual-use issues, and those which assess the regulation of information being generated by current research. Both types of initiatives are premised on a cautious, risk-adverse philosophy which advocates careful examination of all future endpoints of research endeavors. This caution advocated within initiatives such as pre-publication review of journal articles contrasts to the obligation to share underpinning data sharing discussions. As the dual-use debate has yet to make a significant impact on data sharing discussions (and vice versa) it is possible that these two areas of knowledge control may present areas of ethical conflict for scientists, and thus need to be more closely examined. This paper examines the tension between the obligation to share exemplified by data sharing principles and the concerns raised by the risk-cautious culture of the dual-use debates. The paper concludes by reflecting on the issues of responsibility as raised by dual-use as relating to data sharing, such as the chain of custody for shared data.

  11. 14 CFR 23.399 - Dual control system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Dual control system. 23.399 Section 23.399 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... Loads § 23.399 Dual control system. (a) Each dual control system must be designed to withstand the force...

  12. 14 CFR 23.399 - Dual control system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Dual control system. 23.399 Section 23.399 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... Loads § 23.399 Dual control system. (a) Each dual control system must be designed to withstand the force...

  13. 14 CFR 23.399 - Dual control system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Dual control system. 23.399 Section 23.399 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... Loads § 23.399 Dual control system. (a) Each dual control system must be designed to withstand the force...

  14. 14 CFR 23.399 - Dual control system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Dual control system. 23.399 Section 23.399 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... Loads § 23.399 Dual control system. (a) Each dual control system must be designed to withstand the force...

  15. 14 CFR 23.399 - Dual control system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Dual control system. 23.399 Section 23.399 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... Loads § 23.399 Dual control system. (a) Each dual control system must be designed to withstand the force...

  16. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Dual voltage generators. 183.324 Section 183.324... TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The...

  17. Dual Kidney Allocation Score: A Novel Algorithm Utilizing Expanded Donor Criteria for the Allocation of Dual Kidneys in Adults.

    PubMed

    Johnson, Adam P; Price, Thea P; Lieby, Benjamin; Doria, Cataldo

    2016-09-08

    BACKGROUND Dual kidney transplantation (DKT) of expanded-criteria donors is a cost-intensive procedure that aims to increase the pool of available deceased organ donors and has demonstrated equivalent outcomes to expanded-criteria single kidney transplantation (eSKT). The objective of this study was to develop an allocation score based on predicted graft survival from historical dual and single kidney donors. MATERIAL AND METHODS We analyzed United Network for Organ Sharing (UNOS) data for 1547 DKT and 26 381 eSKT performed between January 1994 and September 2013. We utilized multivariable Cox regression to identify variables independently associated with graft survival in dual and single kidney transplantations. We then derived a weighted multivariable product score from calculated hazard ratios to model the benefit of transplantation as dual kidneys. RESULTS Of 36 donor variables known at the time of listing, 13 were significantly associated with graft survival. The derived dual allocation score demonstrated good internal validity with strong correlation to improved survival in dual kidney transplants. Donors with scores less than 2.1 transplanted as dual kidneys had a worsened median survival of 594 days (24%, p-value 0.031) and donors with scores greater than 3.9 had improved median survival of 1107 days (71%, p-value 0.002). There were 17 733 eSKT (67%) and 1051 DKT (67%) with scores in between these values and no differences in survival (p-values 0.676 and 0.185). CONCLUSIONS We have derived a dual kidney allocation score (DKAS) with good internal validity. Future prospective studies will be required to demonstrate external validity, but this score may help to standardize organ allocation for dual kidney transplantation.

  18. Dual Treatments as Starting Point for Integrative Perceptions in Teaching Mathematics

    ERIC Educational Resources Information Center

    Kërënxhi, Svjetllana; Gjoci, Pranvera

    2015-01-01

    In this paper, we recommend mathematical teaching through dual treatments. The dual treatments notion, classified in dual interpretations, dual analyses, dual solutions, and dual formulations, is explained through concrete examples taken from mathematical textbooks of elementary education. Dual treatments provide opportunities for creating…

  19. Dual Coding, Reasoning and Fallacies.

    ERIC Educational Resources Information Center

    Hample, Dale

    1982-01-01

    Develops the theory that a fallacy is not a comparison of a rhetorical text to a set of definitions but a comparison of one person's cognition with another's. Reviews Paivio's dual coding theory, relates nonverbal coding to reasoning processes, and generates a limited fallacy theory based on dual coding theory. (PD)

  20. Governance of dual-use research: an ethical dilemma

    PubMed Central

    2009-01-01

    Abstract Scenarios where the results of well-intentioned scientific research can be used for both good and harmful purposes give rise to what is now widely known as the “dual-use dilemma”. There has been growing debate about the dual-use nature of life science research with implications for making biological weapons. This paper reviews several controversial publications that have been the focus of debates about dual-use life science research and critically examines relevant policy developments, particularly in the United States of America. Though the dual-use dilemma is inherently ethical in nature, the majority of debates about dual-use research have primarily involved science and security experts rather than ethicists. It is important that there is more ethical input into debates about the governance of dual-use research. PMID:19784453

  1. Are factors related to dual-task performance in people with Parkinson's disease dependent on the type of dual task?

    PubMed

    Strouwen, Carolien; Molenaar, Esther A L M; Keus, Samyra H J; Münks, Liesbeth; Heremans, Elke; Vandenberghe, Wim; Bloem, Bastiaan R; Nieuwboer, Alice

    2016-02-01

    Impaired dual-task performance significantly impacts upon functional mobility in people with Parkinson's disease (PD). The aim of this study was to identify determinants of dual-task performance in people with PD in three different dual tasks to assess their possible task-dependency. We recruited 121 home-dwelling patients with PD (mean age 65.93 years; mean disease duration 8.67 years) whom we subjected to regular walking (control condition) and to three dual-task conditions: walking combined with a backwards Digit Span task, an auditory Stroop task and a Mobile Phone task. We measured dual-task gait velocity using the GAITRite mat and dual-task reaction times and errors on the concurrent tasks as outcomes. Motor, cognitive and descriptive variables which correlated to dual-task performance (p < 0.20) were entered into a stepwise forward multiple linear regression model. Single-task gait velocity and executive function, tested by the alternating intake test, was significantly associated with gait velocity during the Digit Span (R(2) = 0.65; p < 0.001), the Stroop (R(2) = 0.73; p < 0.001) and the Mobile Phone task (R(2) = 0.62; p < 0.001). In addition, disease severity proved correlated to gait velocity during the Stroop task. Age was a surplus determinant of gait velocity while using a mobile phone. Single-task gait velocity and executive function as measured by a verbal fluency switching task were independent determinants of dual-task gait performance in people with PD. In contrast to expectation, these factors were the same across different tasks, supporting the robustness of the findings. Future study needs to determine whether these factors predict dual-task abnormalities prospectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Dual use research: investigation across multiple science disciplines.

    PubMed

    Oltmann, Shannon

    2015-04-01

    Most recent studies of dual use research have focused on the life sciences, although some researchers have suggested that dual use research occurs across many disciplines. This research is an initial investigation into the prevalence of dual use research in other scientific disciplines by surveying senior editors of scientific journals, drawn from Journal Citation Reports. The survey was emailed to 7,500 journal editors with a response rate of 10.1 %. Approximately 4.8 % of life science editors reported they had to consider whether to publish dual use research and 38.9 % said they decided to not publish the research in question. In disciplines other than the life sciences, 7.2 % of editors from other science disciplines reported that they had to consider whether to publish dual use research, and 48.4 % declined to publish it. The survey investigated relationships between dual use and the journal's source of funding and place of publication, but no relationships were found. Further research is needed to better understand the occurrence of dual use research in other science disciplines.

  3. Dual Credit Instructor and Counselor Opinions Concerning the Effectiveness of Dual Credit Programs on Post-Secondary Readiness in Southwest Missouri

    ERIC Educational Resources Information Center

    Cook, Natalie Gail

    2017-01-01

    Dual enrollment numbers continue to increase in public school districts; therefore, dual credit programs must be effective for students, adequately challenging them academically and preparing them for the college environment (Flores, 2014). The intention of this study was to survey dual credit instructors and counselors to determine their opinions…

  4. The dual economy in long-run development

    PubMed Central

    2013-01-01

    A salient feature of developing economies is the coexistence of a modern commercial sector alongside a traditional subsistence sector—the dual economy. The apparent differences in productivity between sectors imply substantial losses in aggregate productivity. Existing theories of the dual economy rely on exogenous price distortions, and cannot explain why or if these distortions evolve over the course of development. This paper provides a model of the dual economy in which the productivity differences arise endogenously because of a non-separability between the value of market and non-market time in the traditional sector. Incorporating endogenous fertility, the model then demonstrates how a dual economy will originate, persist, and eventually disappear within a unified growth framework. An implication is that traditional sector productivity growth will exacerbate the inefficiencies of a dual economy and produce slower overall growth than will modern sector productivity improvements. PMID:23946556

  5. Dual microcather-dual detachable coil technique in embolization for a congenital intrahepatic portosystemic venous shunt (IPSVS).

    PubMed

    Suzuki, Kazushi; Shimohira, Masashi; Hashizume, Takuya; Suzuki, Yosuke; Shibamoto, Yuta

    2013-09-01

    We report a 14-year-old boy with a large intrahepatic portosystemic venous shunt. The shunt seemed to be difficult to coil embolize because it was so large and short. However, it was successfully treated by coil embolization with a new dual microcatheter-dual detachable coil technique.

  6. Discrete-continuous variable structural synthesis using dual methods

    NASA Technical Reports Server (NTRS)

    Schmit, L. A.; Fleury, C.

    1980-01-01

    Approximation concepts and dual methods are extended to solve structural synthesis problems involving a mix of discrete and continuous sizing type of design variables. Pure discrete and pure continuous variable problems can be handled as special cases. The basic mathematical programming statement of the structural synthesis problem is converted into a sequence of explicit approximate primal problems of separable form. These problems are solved by constructing continuous explicit dual functions, which are maximized subject to simple nonnegativity constraints on the dual variables. A newly devised gradient projection type of algorithm called DUAL 1, which includes special features for handling dual function gradient discontinuities that arise from the discrete primal variables, is used to find the solution of each dual problem. Computational implementation is accomplished by incorporating the DUAL 1 algorithm into the ACCESS 3 program as a new optimizer option. The power of the method set forth is demonstrated by presenting numerical results for several example problems, including a pure discrete variable treatment of a metallic swept wing and a mixed discrete-continuous variable solution for a thin delta wing with fiber composite skins.

  7. Faculty-Student Dual Relationships: Implications for Counselor Educators

    ERIC Educational Resources Information Center

    Jackson, James L.

    2007-01-01

    This article considers dual relationships between faculty and students from an ethical perspective. A review of the literature focuses on the potential impact of dual relationships on students, faculty, academic institutions, and the consumers students will ultimately serve. Models promoting ethical dual relationships are identified and strategies…

  8. Microresonator soliton dual-comb spectroscopy

    NASA Astrophysics Data System (ADS)

    Suh, Myoung-Gyun; Yang, Qi-Fan; Yang, Ki Youl; Yi, Xu; Vahala, Kerry J.

    2016-11-01

    Measurement of optical and vibrational spectra with high resolution provides a way to identify chemical species in cluttered environments and is of general importance in many fields. Dual-comb spectroscopy has emerged as a powerful approach for acquiring nearly instantaneous Raman and optical spectra with unprecedented resolution. Spectra are generated directly in the electrical domain, without the need for bulky mechanical spectrometers. We demonstrate a miniature soliton-based dual-comb system that can potentially transfer the approach to a chip platform. These devices achieve high-coherence pulsed mode locking. They also feature broad, reproducible spectral envelopes, an essential feature for dual-comb spectroscopy. Our work shows the potential for integrated spectroscopy with high signal-to-noise ratios and fast acquisition rates.

  9. Dual adaptive control: Design principles and applications

    NASA Technical Reports Server (NTRS)

    Mookerjee, Purusottam

    1988-01-01

    The design of an actively adaptive dual controller based on an approximation of the stochastic dynamic programming equation for a multi-step horizon is presented. A dual controller that can enhance identification of the system while controlling it at the same time is derived for multi-dimensional problems. This dual controller uses sensitivity functions of the expected future cost with respect to the parameter uncertainties. A passively adaptive cautious controller and the actively adaptive dual controller are examined. In many instances, the cautious controller is seen to turn off while the latter avoids the turn-off of the control and the slow convergence of the parameter estimates, characteristic of the cautious controller. The algorithms have been applied to a multi-variable static model which represents a simplified linear version of the relationship between the vibration output and the higher harmonic control input for a helicopter. Monte Carlo comparisons based on parametric and nonparametric statistical analysis indicate the superiority of the dual controller over the baseline controller.

  10. Dual Nozzle Aerodynamic and Cooling Analysis Study.

    DTIC Science & Technology

    1981-02-27

    program and to the aerodynamic model computer program. This pro - cedure was used to define two secondary nozzle contours for the baseline con - figuration...both the dual-throat and dual-expander con - cepts. Advanced analytical techniques were utilized to provide quantitative estimates of the bleed flow...preliminary heat transfer analysis of both con - cepts, and (5) engineering analysis of data from the NASA/MSFC hot-fire testing of a dual-throat

  11. Adaptive sampling dual terahertz comb spectroscopy using dual free-running femtosecond lasers.

    PubMed

    Yasui, Takeshi; Ichikawa, Ryuji; Hsieh, Yi-Da; Hayashi, Kenta; Cahyadi, Harsono; Hindle, Francis; Sakaguchi, Yoshiyuki; Iwata, Tetsuo; Mizutani, Yasuhiro; Yamamoto, Hirotsugu; Minoshima, Kaoru; Inaba, Hajime

    2015-06-02

    Terahertz (THz) dual comb spectroscopy (DCS) is a promising method for high-accuracy, high-resolution, broadband THz spectroscopy because the mode-resolved THz comb spectrum includes both broadband THz radiation and narrow-line CW-THz radiation characteristics. In addition, all frequency modes of a THz comb can be phase-locked to a microwave frequency standard, providing excellent traceability. However, the need for stabilization of dual femtosecond lasers has often hindered its wide use. To overcome this limitation, here we have demonstrated adaptive-sampling THz-DCS, allowing the use of free-running femtosecond lasers. To correct the fluctuation of the time and frequency scales caused by the laser timing jitter, an adaptive sampling clock is generated by dual THz-comb-referenced spectrum analysers and is used for a timing clock signal in a data acquisition board. The results not only indicated the successful implementation of THz-DCS with free-running lasers but also showed that this configuration outperforms standard THz-DCS with stabilized lasers due to the slight jitter remained in the stabilized lasers.

  12. Adaptive sampling dual terahertz comb spectroscopy using dual free-running femtosecond lasers

    PubMed Central

    Yasui, Takeshi; Ichikawa, Ryuji; Hsieh, Yi-Da; Hayashi, Kenta; Cahyadi, Harsono; Hindle, Francis; Sakaguchi, Yoshiyuki; Iwata, Tetsuo; Mizutani, Yasuhiro; Yamamoto, Hirotsugu; Minoshima, Kaoru; Inaba, Hajime

    2015-01-01

    Terahertz (THz) dual comb spectroscopy (DCS) is a promising method for high-accuracy, high-resolution, broadband THz spectroscopy because the mode-resolved THz comb spectrum includes both broadband THz radiation and narrow-line CW-THz radiation characteristics. In addition, all frequency modes of a THz comb can be phase-locked to a microwave frequency standard, providing excellent traceability. However, the need for stabilization of dual femtosecond lasers has often hindered its wide use. To overcome this limitation, here we have demonstrated adaptive-sampling THz-DCS, allowing the use of free-running femtosecond lasers. To correct the fluctuation of the time and frequency scales caused by the laser timing jitter, an adaptive sampling clock is generated by dual THz-comb-referenced spectrum analysers and is used for a timing clock signal in a data acquisition board. The results not only indicated the successful implementation of THz-DCS with free-running lasers but also showed that this configuration outperforms standard THz-DCS with stabilized lasers due to the slight jitter remained in the stabilized lasers. PMID:26035687

  13. 20 CFR 226.12 - Employee vested dual benefit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false Employee vested dual benefit. 226.12 Section 226.12 Employees' Benefits RAILROAD RETIREMENT BOARD REGULATIONS UNDER THE RAILROAD RETIREMENT ACT... vested dual benefit. (a) General. An employee vested dual benefit is payable, in addition to tiers I and...

  14. 20 CFR 226.12 - Employee vested dual benefit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 1 2013-04-01 2012-04-01 true Employee vested dual benefit. 226.12 Section 226.12 Employees' Benefits RAILROAD RETIREMENT BOARD REGULATIONS UNDER THE RAILROAD RETIREMENT ACT... vested dual benefit. (a) General. An employee vested dual benefit is payable, in addition to tiers I and...

  15. 20 CFR 226.12 - Employee vested dual benefit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 1 2012-04-01 2012-04-01 false Employee vested dual benefit. 226.12 Section 226.12 Employees' Benefits RAILROAD RETIREMENT BOARD REGULATIONS UNDER THE RAILROAD RETIREMENT ACT... vested dual benefit. (a) General. An employee vested dual benefit is payable, in addition to tiers I and...

  16. Generalized Hodge dual for torsion in teleparallel gravity

    NASA Astrophysics Data System (ADS)

    Huang, Peng; Yuan, Fang-Fang

    2016-07-01

    For teleparallel gravity in four dimensions, Lucas and Pereira have shown that its action can be constructed via a generalized Hodge dual for torsion tensor. In this paper, we demonstrate that a direct generalization of this approach to other dimensions fails due to the fact that no generalized Hodge dual operator could be given in general dimensions. Furthermore, if one enforces the definition of a generalized Hodge dual to be consistent with the action of teleparallel gravity in general dimensions, the basic identity for any sensible Hodge dual would require an ad hoc definition for the second Hodge dual operation which is totally unexpected. Therefore, we conclude that at least for the torsion tensor, the observation of Lucas and Pereira only applies to four dimensions.

  17. Oxygen/Alcohol Dual Thrust RCS Engines

    NASA Technical Reports Server (NTRS)

    Angstadt, Tara; Hurlbert, Eric

    1999-01-01

    A non-toxic dual thrust RCS engine offers significant operational, safety, and performance advantages to the space shuttle and the next generation RLVs. In this concept, a single engine produces two thrust levels of 25 and 870 lbf. The low thrust level is provided by the spark torch igniter, which, with the addition of 2 extra valves, can also be made to function as a vernier. A dual thrust RCS engine allows 38 verniers to be packaged more efficiently on a vehicle. These 38 vemiers improve translation and reduce cross coupling, thereby providing more pure roll, pitch, and yaw maneuvers of the vehicle. Compared to the 6 vemiers currently on the shuttle, the 38 dual thrust engines would be 25 to 40% more efficient for the same maneuvers and attitude control. The vernier thrust level also reduces plume impingement and contamination concerns. Redundancy is also improved, thereby improving mission success reliability. Oxygen and ethanol are benign propellants which do not create explosive reaction products or contamination, as compared to hypergolic propellants. These characteristics make dual-thrust engines simpler to implement on a non-toxic reaction control system. Tests at WSTF in August 1999 demonstrated a dual-thrust concept that is successful with oxygen and ethanol. Over a variety of inlet pressures and mixture ratios at 22:1 area ratio, the engine produced between 230 and 297 sec Isp, and thrust levels from 8 lbf. to 50 lbf. This paper describes the benefits of dual-thrust engines and the recent results from tests at WSTF.

  18. Psychosocial approaches to dual diagnosis.

    PubMed

    Drake, R E; Mueser, K T

    2000-01-01

    Recent research elucidates many aspects of the problem of co-occurring substance use disorder (SUD) in patients with severe mental illness, which is often termed dual diagnosis. This paper provides a brief overview of current research on the epidemiology, adverse consequences, and phenomenology of dual diagnosis, followed by a more extensive review of current approaches to services, assessment, and treatment. Accumulating evidence shows that comorbid SUD is quite common among individuals with severe mental illness and that these individuals suffer serious adverse consequences of SUD. The research further suggests that traditional, separate services for individuals with dual disorders are ineffective, and that integrated treatment programs, which combine mental health and substance abuse interventions, offer more promise. In addition to a comprehensive integration of services, successful programs include assessment, assertive case management, motivational interventions for patients who do not recognize the need for substance abuse treatment, behavioral interventions for those who are trying to attain or maintain abstinence, family interventions, housing, rehabilitation, and psychopharmacology. Further research is needed on the organization and financing of dual-diagnosis services and on specific components of the integrated treatment model, such as group treatments, family interventions, and housing approaches.

  19. Dual wound dc brush motor gearhead

    NASA Technical Reports Server (NTRS)

    Henson, Barrie W.

    1986-01-01

    The design requirements, the design, development tests and problems, the qualification and life test and the findings of the strip examination of a dual wound DC brushed motor gearhead are described. It is the only space qualified dual wound dc brushed motor gearhead in Europe.

  20. 30 CFR 62.140 - Dual hearing protection level.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Dual hearing protection level. 62.140 Section... HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.140 Dual hearing protection level. If during any work shift a miner's noise exposure exceeds the dual hearing protection level, the mine operator must, in...

  1. 30 CFR 62.140 - Dual hearing protection level.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Dual hearing protection level. 62.140 Section... HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.140 Dual hearing protection level. If during any work shift a miner's noise exposure exceeds the dual hearing protection level, the mine operator must, in...

  2. Dual infections with different Legionella strains.

    PubMed

    Wewalka, G; Schmid, D; Harrison, T G; Uldum, S A; Lück, C

    2014-01-01

    In 2010 a case of a dual infection with Legionella pneumophila serogroup (sg) 1 and sg 3 was identified by culture of a blood sample collected from a female Austrian patient with septic pneumonia. Subsequently all 35 European National Legionella Reference Laboratories were interviewed regarding the frequency of dual infections in legionellosis. The Reference Laboratories in Denmark, the UK and Germany reported the detection of another 14 cases of dual infections with different Legionella strains between 2002 and 2012. Among the 15 cases, there were four cases with different Legionella species, six cases with different L. pneumophila serogroups, and five cases of dual infections with L. pneumophila sg 1 with different MAb-types. The median age of the 15 cases was 56 years and the male to female ratio 1:1.14. Six of the 15 patients were receiving immunosuppressive treatment following organ transplantation (n = 3) or for underlying haematological and solid malignancies (n = 3). Five of the 15 cases died within 30 days following diagnosis. Efforts to detect dual infections with different Legionella strains will improve our ability to correctly elucidate the causative sources of infection and enhance our understanding of the epidemiology of Legionella infections. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  3. Interventions to manage dual practice among health workers.

    PubMed

    Kiwanuka, Suzanne N; Rutebemberwa, Elizeus; Nalwadda, Christine; Okui, Olico; Ssengooba, Freddie; Kinengyere, Alison A; Pariyo, George W

    2011-07-06

    Dual practice, whereby health workers hold two or more jobs, is a common phenomenon globally. In resource constrained low- and middle-income countries dual practice poses an ongoing threat to the efficiency, quality and equity of health services, especially in the public sector. Identifying effective interventions to manage dual practice is important. To assess the effects of regulations implemented to manage dual practice. Databases searched included: The Cochrane Central Register of Controlled Trials (CENTRAL) 2011, Issue 4, part of The Cochrane Library. www.thecochranelibrary.com, including the Cochrane Effective Practice and Organisation of Care (EPOC) Group Specialised Register (searched 26 May 2011); MEDLINE In-Process & Other Non-Indexed Citations May 24, 2011 (searched 26 May 2011); MEDLINE, Ovid (1948 to May week 2 2011) (searched 26 May 2011); EMBASE, Ovid (1980 to 2011 week 20) (searched 26 May 2011); Science Citation Index and Social Sciences Citation Index, ISI Web of Science (1975 to present) (searched 04 December 2009); LILACS (searched January 2010); and AIM (December 2009) (searched 18 December 2009). Randomized controlled trials, non-randomized controlled trials, controlled before-and-after studies and interrupted-time-series studies. Dual practice was defined as holding more than one job. Studies for inclusion were those focusing on interventions to manage dual practice among health professionals employed in the public health sector. Two review authors independently applied the criteria for inclusion and exclusion of studies when scanning the identified titles and abstracts. The same two review authors independently screened full reports of selected citations. At each stage, results were compared and discrepancies settled through discussion. No studies were found which were eligible for inclusion in this review. There is a need to rigorously evaluate the effects of interventions implemented to manage dual practice among health workers. However

  4. [Dual-doctor marriages].

    PubMed

    Gjerberg, Elisabeth

    2003-08-28

    Dual-doctor marriages are increasingly frequent. The question raised here is whether being married to a fellow physician has a different impact on a doctor's career and family life than having a spouse in a different profession. In 1996 a questionnaire was mailed to physicians who received their authorisation to practise medicine in Norway in the years 1980 through 1983 period; 1142 responded (67 %). They supplied data on their current employment status and data on employment history and marital background. Multivariate analysis was used in order to explore how the educational background of spouses affects a medical career. Female physicians who marry a physician marry and have families at a younger age than other female physicians. Moreover, they more often enter specialties; in some specialities they also qualify earlier than those who marry non-physicians. The same did not hold for male physicians. However, male physicians in dual-doctor marriages more frequently worked part time and they far less frequently had spouses working part time than other male doctors. The results suggest that dual-doctor couples to a higher extent share in giving care to their families, have more interests in common and are more supportive of each other's needs. Female physicians seem to benefit particularly.

  5. Dual-Schemata Model

    NASA Astrophysics Data System (ADS)

    Taniguchi, Tadahiro; Sawaragi, Tetsuo

    In this paper, a new machine-learning method, called Dual-Schemata model, is presented. Dual-Schemata model is a kind of self-organizational machine learning methods for an autonomous robot interacting with an unknown dynamical environment. This is based on Piaget's Schema model, that is a classical psychological model to explain memory and cognitive development of human beings. Our Dual-Schemata model is developed as a computational model of Piaget's Schema model, especially focusing on sensori-motor developing period. This developmental process is characterized by a couple of two mutually-interacting dynamics; one is a dynamics formed by assimilation and accommodation, and the other dynamics is formed by equilibration and differentiation. By these dynamics schema system enables an agent to act well in a real world. This schema's differentiation process corresponds to a symbol formation process occurring within an autonomous agent when it interacts with an unknown, dynamically changing environment. Experiment results obtained from an autonomous facial robot in which our model is embedded are presented; an autonomous facial robot becomes able to chase a ball moving in various ways without any rewards nor teaching signals from outside. Moreover, emergence of concepts on the target movements within a robot is shown and discussed in terms of fuzzy logics on set-subset inclusive relationships.

  6. 49 CFR 538.9 - Dual fuel vehicle incentive.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 6 2011-10-01 2011-10-01 false Dual fuel vehicle incentive. 538.9 Section 538.9... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION MANUFACTURING INCENTIVES FOR ALTERNATIVE FUEL VEHICLES § 538.9 Dual fuel vehicle incentive. The application of 49 U.S.C. 32905(b) and (d) to qualifying dual fuel vehicles...

  7. 49 CFR 538.9 - Dual fuel vehicle incentive.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Dual fuel vehicle incentive. 538.9 Section 538.9... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION MANUFACTURING INCENTIVES FOR ALTERNATIVE FUEL VEHICLES § 538.9 Dual fuel vehicle incentive. The application of 49 U.S.C. 32905(b) and (d) to qualifying dual fuel vehicles...

  8. 49 CFR 538.9 - Dual fuel vehicle incentive.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 6 2013-10-01 2013-10-01 false Dual fuel vehicle incentive. 538.9 Section 538.9... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION MANUFACTURING INCENTIVES FOR ALTERNATIVE FUEL VEHICLES § 538.9 Dual fuel vehicle incentive. The application of 49 U.S.C. 32905(b) and (d) to qualifying dual fuel vehicles...

  9. 49 CFR 538.9 - Dual fuel vehicle incentive.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Dual fuel vehicle incentive. 538.9 Section 538.9... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION MANUFACTURING INCENTIVES FOR ALTERNATIVE FUEL VEHICLES § 538.9 Dual fuel vehicle incentive. The application of 49 U.S.C. 32905(b) and (d) to qualifying dual fuel vehicles...

  10. Enhancement of Dual-Band Reflection-Mode Circular Polarizers Using Dual-Layer Rectangular Frequency Selective Surfaces

    NASA Astrophysics Data System (ADS)

    Fartookzadeh, M.; Mohseni Armaki, S. H.

    2016-10-01

    A new kind of dual-band reflection-mode circular polarizers (RMCPs) is introduced with wide bandwidth and wide-view at the operating frequencies. The proposed RMCPs are based on dual-layer rectangular patches on both sides of a substrate, separated by a foam or air layer from the ground plane. Required TE susceptance of the first layer patches to produce circular polarization is calculated using the equivalent transmission line model. Dimensions of the RMCP are obtained using parametrical study for the two frequency bands, 1.9-2.3 GHz and 7.9-8.3 GHz. In addition, it is indicated that the accepted view angle and bandwidth of the proposed dual-layer RMCP are improved compared with the single layer RMCP, significantly. Moreover, a tradeoff is observed for the dual-layer RMCP on the bandwidths of X band and S band that can be controlled by propagation angle of the incident wave. The proposed RMCP has 30.5 % and 33.7 % bandwidths for less than 3 dB axial ratio with incident angles {\\theta}max=50{\\deg} and {\\theta}min=35{\\deg}. Finally, simulation results are met by the measurement for three angles of the incident wave.

  11. Dual methods and approximation concepts in structural synthesis

    NASA Technical Reports Server (NTRS)

    Fleury, C.; Schmit, L. A., Jr.

    1980-01-01

    Approximation concepts and dual method algorithms are combined to create a method for minimum weight design of structural systems. Approximation concepts convert the basic mathematical programming statement of the structural synthesis problem into a sequence of explicit primal problems of separable form. These problems are solved by constructing explicit dual functions, which are maximized subject to nonnegativity constraints on the dual variables. It is shown that the joining together of approximation concepts and dual methods can be viewed as a generalized optimality criteria approach. The dual method is successfully extended to deal with pure discrete and mixed continuous-discrete design variable problems. The power of the method presented is illustrated with numerical results for example problems, including a metallic swept wing and a thin delta wing with fiber composite skins.

  12. Methods of Attenuation Correction for Dual-Wavelength and Dual-Polarization Weather Radar Data

    NASA Technical Reports Server (NTRS)

    Meneghini, R.; Liao, L.

    2007-01-01

    In writing the integral equations for the median mass diameter and number concentration, or comparable parameters of the raindrop size distribution, it is apparent that the forms of the equations for dual-polarization and dual-wavelength radar data are identical when attenuation effects are included. The differential backscattering and extinction coefficients appear in both sets of equations: for the dual-polarization equations, the differences are taken with respect to polarization at a fixed frequency while for the dual-wavelength equations, the differences are taken with respect to frequency at a fixed polarization. An alternative to the integral equation formulation is that based on the k-Z (attenuation coefficient-radar reflectivity factor) parameterization. This-technique was originally developed for attenuating single-wavelength radars, a variation of which has been applied to the TRMM Precipitation Radar data (PR). Extensions of this method have also been applied to dual-polarization data. In fact, it is not difficult to show that nearly identical equations are applicable as well to dualwavelength radar data. In this case, the equations for median mass diameter and number concentration take the form of coupled, but non-integral equations. Differences between this and the integral equation formulation are a consequence of the different ways in which attenuation correction is performed under the two formulations. For both techniques, the equations can be solved either forward from the radar outward or backward from the final range gate toward the radar. Although the forward-going solutions tend to be unstable as the attenuation out to the range of interest becomes large in some sense, an independent estimate of path attenuation is not required. This is analogous to the case of an attenuating single-wavelength radar where the forward solution to the Hitschfeld-Bordan equation becomes unstable as the attenuation increases. To circumvent this problem, the

  13. Dual Mode Slotted Monopole Antenna

    DTIC Science & Technology

    2017-01-05

    of 15 DUAL MODE SLOTTED MONOPOLE ANTENNA STATEMENT OF GOVERNMENT INTEREST [0001] The invention described herein may be manufactured and used by...to a dual mode antenna having one mode as a slotted cylinder antenna and another mode as a monopole antenna . (2) Description of the Prior Art...0004] Slotted cylinder antennas are popular antennas for use in line of sight communications systems, especially where the carrier frequency exceeds

  14. SU-G-IeP2-15: Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual- Energy CT Projection Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrero, A; Chen, B; Huang, A

    Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previouslymore » developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and

  15. Method and system for dual resolution translation stage

    DOEpatents

    Halpin, John Michael

    2014-04-22

    A dual resolution translation stage includes a stage assembly operable to receive an optical element and a low resolution adjustment device mechanically coupled to the stage assembly. The dual resolution stage also includes an adjustable pivot block mechanically coupled to the stage assembly. The adjustable pivot block includes a pivot shaft. The dual resolution stage further includes a lever arm mechanically coupled to the adjustable pivot block. The lever arm is operable to pivot about the pivot shaft. The dual resolution stage additionally includes a high resolution adjustment device mechanically coupled to the lever arm and the stage assembly.

  16. Musical expertise has minimal impact on dual task performance.

    PubMed

    Cocchini, Gianna; Filardi, Maria Serena; Crhonkova, Marcela; Halpern, Andrea R

    2017-05-01

    Studies investigating effect of practice on dual task performance have yielded conflicting findings, thus supporting different theoretical accounts about the organisation of attentional resources when tasks are performed simultaneously. Because practice has been proven to reduce the demand of attention for the trained task, the impact of long-lasting training on one task is an ideal way to better understand the mechanisms underlying dual task decline in performance. Our study compared performance during dual task execution in expert musicians compared to controls with little if any musical experience. Participants performed a music recognition task and a visuo-spatial task separately (single task) or simultaneously (dual task). Both groups showed a significant but similar performance decline during dual tasks. In addition, the two groups showed a similar decline of dual task performance during encoding and retrieval of the musical information, mainly attributed to a decline in sensitivity. Our results suggest that attention during dual tasks is similarly distributed by expert and non-experts. These findings are in line with previous studies showing a lack of sensitivity to difficulty and lack of practice effect during dual tasks, supporting the idea that different tasks may rely on different and not-sharable attentional resources.

  17. Dual mode nuclear rocket system applications.

    NASA Technical Reports Server (NTRS)

    Boretz, J. E.; Bell, J. M.; Plebuch, R. K.; Priest, C. C.

    1972-01-01

    Mission areas where the dual-mode nuclear rocket system is superior to nondual-mode systems are demonstrated. It is shown that the dual-mode system is competitive with the nondual-mode system even for those specific missions and particular payload configurations where it does not have a clear-cut advantage.

  18. Departmental Issues in Dual-Academic Marriages.

    ERIC Educational Resources Information Center

    Barbee, Anita P.; Cunningham, Michael R.

    This paper discusses issues pertaining to the recruitment and hiring of dual-career academic couples by universities and psychology departments. Studies have shown that both husbands and wives in dual psychologist couples are more productive in number of publications, paper presentations, and grants awarded than their single counterparts, yet many…

  19. 7 CFR 7.17 - Dual office.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 1 2010-01-01 2010-01-01 false Dual office. 7.17 Section 7.17 Agriculture Office of... STATE, COUNTY AND COMMUNITY COMMITTEES § 7.17 Dual office. (a) County committee membership. A member of... any other county office employee. (b) Community committee membership. A member of the community...

  20. Dual throat engine design for a SSTO launch vehicle

    NASA Technical Reports Server (NTRS)

    Obrien, C. J.; Salmon, J. W.

    1980-01-01

    A propulsion system analysis of a dual fuel, dual throat engine for launch vehicle application was conducted. Basic dual throat engine characterization data are presented to allow vehicle optimization studies to be conducted. A preliminary baseline engine system was defined. Dual throat engine performance, envelope, and weight parametric data were generated over the parametric range of thrust from 890 to 8896 KN (200K to 2M lb-force), chamber pressure from 6.89 million to 34.5 million N/sq m (1000 to 5000 psia) thrust ratio from 1.2 to 5, and a range of mixture ratios for the two tripropellant combinations: LO2/RP-1 + LH2 and LO2/LCH4 + LH2. The results of the study indicate that the dual fuel dual throat engine is a viable single stage to orbit candidate.

  1. Dual-Energy Computed Tomography: Image Acquisition, Processing, and Workflow.

    PubMed

    Megibow, Alec J; Kambadakone, Avinash; Ananthakrishnan, Lakshmi

    2018-07-01

    Dual energy computed tomography has been available for more than 10 years; however, it is currently on the cusp of widespread clinical use. The way dual energy data are acquired and assembled must be appreciated at the clinical level so that the various reconstruction types can extend its diagnostic power. The type of scanner that is present in a given practice dictates the way in which the dual energy data can be presented and used. This article compares and contrasts how dual source, rapid kV switching, and spectral technologies acquire and present dual energy reconstructions to practicing radiologists. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Dual antiplatelet treatment in patients candidates for abdominal surgery.

    PubMed

    Illuminati, Giulio; Ceccanei, Gianluca; Pacilè, Maria A; Pizzardi, Giulia; Palumbo, Piergaspare; Vietri, Francesco

    2013-01-01

    With the increasing diffusion of percutaneous interventions (PCI), surgeons are often faced with the problem of operating on patients under dual antiplatelet treatment. Replacing dual antiplatelet regiment with low molecular weight heparin may expose to the abrupt thrombosis of coronary stent and massive myocardial infarction. The purpose of this study was to test the hypothesis that abdominal operations can be safely performed under dual antiplatelet treatment. Eleven patients underwent 5 colectomies, 3 nefrectomies, 2 gastrectomies and 1 hysterectomy under aspirin and plavix without any significant perioperative hemorrhage. These preliminary results show that abdominal operations can be safely performed under dual antiplatelet regimen. Abdominal surgery, Dual antiplatelet treatment.

  3. Using dual-domain advective-transport simulation to reconcile multiple-tracer ages and estimate dual-porosity transport parameters

    NASA Astrophysics Data System (ADS)

    Sanford, Ward E.; Niel Plummer, L.; Casile, Gerolamo; Busenberg, Ed; Nelms, David L.; Schlosser, Peter

    2017-06-01

    Dual-domain transport is an alternative conceptual and mathematical paradigm to advection-dispersion for describing the movement of dissolved constituents in groundwater. Here we test the use of a dual-domain algorithm combined with advective pathline tracking to help reconcile environmental tracer concentrations measured in springs within the Shenandoah Valley, USA. The approach also allows for the estimation of the three dual-domain parameters: mobile porosity, immobile porosity, and a domain exchange rate constant. Concentrations of CFC-113, SF6, 3H, and 3He were measured at 28 springs emanating from carbonate rocks. The different tracers give three different mean composite piston-flow ages for all the springs that vary from 5 to 18 years. Here we compare four algorithms that interpret the tracer concentrations in terms of groundwater age: piston flow, old-fraction mixing, advective-flow path modeling, and dual-domain modeling. Whereas the second two algorithms made slight improvements over piston flow at reconciling the disparate piston-flow age estimates, the dual-domain algorithm gave a very marked improvement. Optimal values for the three transport parameters were also obtained, although the immobile porosity value was not well constrained. Parameter correlation and sensitivities were calculated to help quantify the uncertainty. Although some correlation exists between the three parameters being estimated, a watershed simulation of a pollutant breakthrough to a local stream illustrates that the estimated transport parameters can still substantially help to constrain and predict the nature and timing of solute transport. The combined use of multiple environmental tracers with this dual-domain approach could be applicable in a wide variety of fractured-rock settings.

  4. Dual frequency comb metrology with one fiber laser

    NASA Astrophysics Data System (ADS)

    Zhao, Xin; Takeshi, Yasui; Zheng, Zheng

    2016-11-01

    Optical metrology techniques based on dual optical frequency combs have emerged as a hotly studied area targeting a wide range of applications from optical spectroscopy to microwave and terahertz frequency measurement. Generating two sets of high-quality comb lines with slightly different comb-tooth spacings with high mutual coherence and stability is the key to most of the dual-comb schemes. The complexity and costs of such laser sources and the associated control systems to lock the two frequency combs hinder the wider adoption of such techniques. Here we demonstrate a very simple and rather different approach to tackle such a challenge. By employing novel laser cavity designs in a mode-locked fiber laser, a simple fiber laser setup could emit dual-comb pulse output with high stability and good coherence between the pulse trains. Based on such lasers, comb-tooth-resolved dual-comb optical spectroscopy is demonstrated. Picometer spectral resolving capability could be realized with a fiber-optic setup and a low-cost data acquisition system and standard algorithms. Besides, the frequency of microwave signals over a large range can be determined based on a simple setup. Our results show the capability of such single-fiber-laser-based dual-comb scheme to reduce the complexity and cost of dual-comb systems with excellent quality for different dual-comb applications.

  5. Dual protection: more needed than practised or understood.

    PubMed

    Berer, Marge

    2006-11-01

    Although non-barrier contraceptive use has become a global norm, unprotected sex in relation to sexually transmitted infections remains the norm almost everywhere. Dual protection is protection from unwanted pregnancy, HIV and other sexually transmitted infections, and is a form of safer sex for heterosexual couples that is more needed than practised or understood. This paper draws on a review of the literature in family planning, obstetrics and gynaecology, and AIDS-related journals from 1998 to early 2005. Definitions of dual protection, found mainly in family planning literature, are very narrow. Condoms remain the mainstay of dual protection, but the aim of this paper is to provide an expanded list of dual protection methods to show that there is a range of options. These include non-penetrative sex and the increasing use of condoms with the back-up of emergency contraception on the part of young people. The fact that people may fail to use dual protection consistently and correctly is not a valid reason not to promote it. It is never too late for those providing family planning and STI/HIV prevention services to start promoting condoms and dual protection. In the long-term, the development of highly efficacious and highly acceptable methods of dual protection is an urgent research priority, starting with a wider range of condoms that will appeal to more people.

  6. Cerebellum and Integration of Neural Networks in Dual-Task Processing

    PubMed Central

    Wu, Tao; Liu, Jun; Hallett, Mark; Zheng, Zheng; Chan, Piu

    2014-01-01

    Performing two tasks simultaneously (dual-task) is common in human daily life. The neural correlates of dual-task processing remain unclear. In the current study, we used a dual motor and counting task with functional MRI (fMRI) to determine whether there are any areas additionally activated for dual-task performance. Moreover, we investigated the functional connectivity of these added activated areas, as well as the training effect on brain activity and connectivity. We found that the right cerebellar vermis, left lobule V of the cerebellar anterior lobe and precuneus are additionally activated for this type of dual-tasking. These cerebellar regions had functional connectivity with extensive motor- and cognitive-related regions. Dual-task training induced less activation in several areas, but increased the functional connectivity between these cerebellar regions and numbers of motor- and cognitive-related areas. Our findings demonstrate that some regions within the cerebellum can be additionally activated with dual-task performance. Their role in dual motor and cognitive task processes is likely to integrate motor and cognitive networks, and may be involved in adjusting these networks to be more efficient in order to perform dual-tasking properly. The connectivity of the precuneus differs from the cerebellar regions. A possible role of the precuneus in dual-task may be monitoring the operation of active brain networks. PMID:23063842

  7. Dual Enrollment as a Liminal Space

    ERIC Educational Resources Information Center

    Hofmann, Eric; Voloch, Daniel

    2012-01-01

    Dual enrollment is a place between high school and college that is neither exclusively one nor the other. Dual enrollment inhabits a space where larger questions about higher education--the cultural practices, norms, institutional relationships and interactions, and the overall "business" of learning--are grappled with on a daily basis. To the…

  8. Support Networks of Dual Career Couples.

    ERIC Educational Resources Information Center

    Lloyd, Sally A.; And Others

    Although social networks play an important role in supporting families under stress, there is some evidence that families living a stressful dual career life style may have limited network resources. To describe support networks of dual career couples and to examine the relationship between the supportiveness of the network and satisfaction with…

  9. Dual Pathology of Mandible

    PubMed Central

    Rajurkar, Suday G.; Deshpande, Mohan D.; Kazi, Noaman; Jadhav, Dhanashree; Ranadive, Pallavi; Ingole, Snehal

    2017-01-01

    Aneurysmal Bone cyst (ABC)is a rare benign lesion of the bone which is infrequent in craniofacial region (12%). Rapid growth pattern causing bone expansion and facial asymmetry is a characteristic feature of ABC. Giant cell lesion is another distinct pathological entity. Here we present to you a rare case of dual pathology in an 11 year old female patient who presented with a large expansile lesion in the left hemimandible. All radiographic investigations were suggestive of ABC, aspiration of the lesion resulted in blood aspirate. However only after a histologic examination the dual nature of the lesion was revealed. PMID:29264307

  10. Dual Pathology of Mandible.

    PubMed

    Rajurkar, Suday G; Deshpande, Mohan D; Kazi, Noaman; Jadhav, Dhanashree; Ranadive, Pallavi; Ingole, Snehal

    2017-01-01

    Aneurysmal Bone cyst (ABC)is a rare benign lesion of the bone which is infrequent in craniofacial region (12%). Rapid growth pattern causing bone expansion and facial asymmetry is a characteristic feature of ABC. Giant cell lesion is another distinct pathological entity. Here we present to you a rare case of dual pathology in an 11 year old female patient who presented with a large expansile lesion in the left hemimandible. All radiographic investigations were suggestive of ABC, aspiration of the lesion resulted in blood aspirate. However only after a histologic examination the dual nature of the lesion was revealed.

  11. Fluorescence and Magnetic Resonance Dual-Modality Imaging-Guided Photothermal and Photodynamic Dual-Therapy with Magnetic Porphyrin-Metal Organic Framework Nanocomposites

    NASA Astrophysics Data System (ADS)

    Zhang, Hui; Li, Yu-Hao; Chen, Yang; Wang, Man-Man; Wang, Xue-Sheng; Yin, Xue-Bo

    2017-03-01

    Phototherapy shows some unique advantages in clinical application, such as remote controllability, improved selectivity, and low bio-toxicity, than chemotherapy. In order to improve the safety and therapeutic efficacy, imaging-guided therapy seems particularly important because it integrates visible information to speculate the distribution and metabolism of the probe. Here we prepare biocompatible core-shell nanocomposites for dual-modality imaging-guided photothermal and photodynamic dual-therapy by the in situ growth of porphyrin-metal organic framework (PMOF) on Fe3O4@C core. Fe3O4@C core was used as T2-weighted magnetic resonance (MR) imaging and photothermal therapy (PTT) agent. The optical properties of porphyrin were well remained in PMOF, and PMOF was therefore selected for photodynamic therapy (PDT) and fluorescence imaging. Fluorescence and MR dual-modality imaging-guided PTT and PDT dual-therapy was confirmed with tumour-bearing mice as model. The high tumour accumulation of Fe3O4@C@PMOF and controllable light excitation at the tumour site achieved efficient cancer therapy, but low toxicity was observed to the normal tissues. The results demonstrated that Fe3O4@C@PMOF was a promising dual-imaging guided PTT and PDT dual-therapy platform for tumour diagnosis and treatment with low cytotoxicity and negligible in vivo toxicity.

  12. Learning from the Past: Dual Credit

    ERIC Educational Resources Information Center

    Mansell, Nicole; Justice, Madeline

    2014-01-01

    This study involved identifying, categorizing, and comparing critical incidents related to qualifying dual credit high school students' decisions to enroll or not to enroll in dual credit coursework in either a traditional or early college high school. The purpose of the study was (a) to identify the reasons qualifying students decide to enroll in…

  13. Systematic Review to Inform Dual Tobacco Use Prevention.

    PubMed

    Evans, William Douglas; Horn, Kimberly A; Gray, Tiffany

    2015-10-01

    With more tobacco products now available and heavily marketed, dual tobacco use is increasing among youth. We systematically reviewed literature on dual tobacco use interventions, with an emphasis on mass health communication strategies. The review identified 46 articles meeting initial criteria and ultimately included 8 articles. Included studies reported a mix of health communication and social marketing techniques. Although there is a body of research on dual tobacco use, there is limited literature describing interventions aimed at controlling it. Design and evaluation of such interventions showing reductions in dual use of cigarettes, smokeless, and alternative products would advance the field. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. The gravity duals of modular Hamiltonians

    DOE PAGES

    Jafferis, Daniel L.; Suh, S. Josephine

    2016-09-12

    In this study, we investigate modular Hamiltonians defined with respect to arbitrary spatial regions in quantum field theory states which have semi-classical gravity duals. We find prescriptions in the gravity dual for calculating the action of the modular Hamiltonian on its defining state, including its dual metric, and also on small excitations around the state. Curiously, use of the covariant holographic entanglement entropy formula leads us to the conclusion that the modular Hamiltonian, which in the quantum field theory acts only in the causal completion of the region, does not commute with bulk operators whose entire gauge-invariant description is space-likemore » to the causal completion of the region.« less

  15. The gravity duals of modular Hamiltonians

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jafferis, Daniel L.; Suh, S. Josephine

    In this study, we investigate modular Hamiltonians defined with respect to arbitrary spatial regions in quantum field theory states which have semi-classical gravity duals. We find prescriptions in the gravity dual for calculating the action of the modular Hamiltonian on its defining state, including its dual metric, and also on small excitations around the state. Curiously, use of the covariant holographic entanglement entropy formula leads us to the conclusion that the modular Hamiltonian, which in the quantum field theory acts only in the causal completion of the region, does not commute with bulk operators whose entire gauge-invariant description is space-likemore » to the causal completion of the region.« less

  16. An Investigation of CTOL Dual-Mode PAVE Concepts

    NASA Technical Reports Server (NTRS)

    Marchman, James F., III; Interatep, Nanyaporn; Skelton, Eugene; Mason, William H.

    2002-01-01

    A study was conducted to assess the feasibility of the dual-mode concept for a personal air vehicle, to determine how constraints differ between the dual-mode concept and a Conventional Takeoff and Landing (CTOL) general aviation aircraft, to recommend a dual-mode vehicle concept, and to recommend areas where further research can contribute to the successful development of a viable PAVE vehicle design.

  17. Dual-filter estimation for rotating-panel sample designs

    Treesearch

    Francis Roesch

    2017-01-01

    Dual-filter estimators are described and tested for use in the annual estimation for national forest inventories. The dual-filter approach involves the use of a moving widow estimator in the first pass, which is used as input to Theil’s mixed estimator in the second pass. The moving window and dual-filter estimators are tested along with two other estimators in a...

  18. Gas Flows in Dual Active Galactic Nuclei

    NASA Astrophysics Data System (ADS)

    Mueller Sanchez, Francisco; Comerford, Julia M.; Davies, Richard; Treister, Ezequiel; Privon, George C.; Nevin, Becky

    2018-06-01

    Dual Active Galactic Nuclei (AGN) are the Rosetta stone to understand the role of galaxy mergers in triggering nuclear activity and regulating black hole (BH) and galaxy growth. But very little is known about the physical processes required to effectively trigger AGN activity and regulate the growth of the two BHs. The work I will present here characterizes for the first time the properties of the stars, gas (molecular, ionized, and highly-ionized) and dust in all the confirmed dual AGN at z < 0.05, using Keck/OSIRIS, VLT/SINFONI, SOFIA/FORCAST, and HST data. I will focus on the interplay between the several complex processes observed in dual AGN, using as an example the prototypical merger system NGC 6240: vigorous star formation, two AGNs, outflowing winds of ionized gas, rippling dust and gas lanes, and tidal tails. In this galaxy, we observe for the first time a dual outflow of different species of gas: an AGN-driven outflow of highly-ionized gas to the northeast and a starburst-driven outflow of ionized hydrogen to the northwest. This shows that stellar feedback and supermassive black hole feedback can work in tandem to regulate the stellar growth of a galaxy after a merger event. These results open a new door to studies of dual AGN and AGN pairs in general, and enable dual AGN to be used, for the first time, for studies of galaxy evolution.

  19. Dual-modality imaging of function and physiology

    NASA Astrophysics Data System (ADS)

    Hasegawa, Bruce H.; Iwata, Koji; Wong, Kenneth H.; Wu, Max C.; Da Silva, Angela; Tang, Hamilton R.; Barber, William C.; Hwang, Andrew B.; Sakdinawat, Anne E.

    2002-04-01

    Dual-modality imaging is a technique where computed tomography or magnetic resonance imaging is combined with positron emission tomography or single-photon computed tomography to acquire structural and functional images with an integrated system. The data are acquired during a single procedure with the patient on a table viewed by both detectors to facilitate correlation between the structural and function images. The resulting data can be useful for localization for more specific diagnosis of disease. In addition, the anatomical information can be used to compensate the correlated radionuclide data for physical perturbations such as photon attenuation, scatter radiation, and partial volume errors. Thus, dual-modality imaging provides a priori information that can be used to improve both the visual quality and the quantitative accuracy of the radionuclide images. Dual-modality imaging systems also are being developed for biological research that involves small animals. The small-animal dual-modality systems offer advantages for measurements that currently are performed invasively using autoradiography and tissue sampling. By acquiring the required data noninvasively, dual-modality imaging has the potential to allow serial studies in a single animal, to perform measurements with fewer animals, and to improve the statistical quality of the data.

  20. Dual-window dual-bandwidth spectroscopic optical coherence tomography metric for qualitative scatterer size differentiation in tissues.

    PubMed

    Tay, Benjamin Chia-Meng; Chow, Tzu-Hao; Ng, Beng-Koon; Loh, Thomas Kwok-Seng

    2012-09-01

    This study investigates the autocorrelation bandwidths of dual-window (DW) optical coherence tomography (OCT) k-space scattering profile of different-sized microspheres and their correlation to scatterer size. A dual-bandwidth spectroscopic metric defined as the ratio of the 10% to 90% autocorrelation bandwidths is found to change monotonically with microsphere size and gives the best contrast enhancement for scatterer size differentiation in the resulting spectroscopic image. A simulation model supports the experimental results and revealed a tradeoff between the smallest detectable scatterer size and the maximum scatterer size in the linear range of the dual-window dual-bandwidth (DWDB) metric, which depends on the choice of the light source optical bandwidth. Spectroscopic OCT (SOCT) images of microspheres and tonsil tissue samples based on the proposed DWDB metric showed clear differentiation between different-sized scatterers as compared to those derived from conventional short-time Fourier transform metrics. The DWDB metric significantly improves the contrast in SOCT imaging and can aid the visualization and identification of dissimilar scatterer size in a sample. Potential applications include the early detection of cell nuclear changes in tissue carcinogenesis, the monitoring of healing tendons, and cell proliferation in tissue scaffolds.

  1. What Makes Dual-Career Marriages Tick?

    ERIC Educational Resources Information Center

    Gilbert, Lucia Albino

    A dual-career family is a family in which both spouses are committed to occupational work and to a family life together and support each other's desires to combine roles that traditionally were viewed as incompatible. Male socialization in the areas of entitlement, dependency, and nurturance can cause problems for men in dual-career marriages. In…

  2. Towards timelike singularity via AdS dual

    NASA Astrophysics Data System (ADS)

    Bhowmick, Samrat; Chatterjee, Soumyabrata

    2017-07-01

    It is well known that Kasner geometry with spacelike singularity can be extended to bulk AdS-like geometry, furthermore, one can study field theory on this Kasner space via its gravity dual. In this paper, we show that there exists a Kasner-like geometry with timelike singularity for which one can construct a dual gravity description. We then study various extremal surfaces including spacelike geodesics in the dual gravity description. Finally, we compute correlators of highly massive operators in the boundary field theory with a geodesic approximation.

  3. Safety and Crashworthiness of Dual Mode Vehicles

    DOT National Transportation Integrated Search

    1974-01-01

    Safety features and the degree of safety expected of dual-mode systems are reviewed. Some of the inherent advantages and disadvantages of dual-mode transportation are also outlined. Possible categories of vehicle safety are defined to aid in developi...

  4. [Application of second generation dual-source computed tomography dual-energy scan mode in detecting pancreatic adenocarcinoma].

    PubMed

    Xue, Hua-dan; Liu, Wei; Sun, Hao; Wang, Xuan; Chen, Yu; Su, Bai-yan; Sun, Zhao-yong; Chen, Fang; Jin, Zheng-yu

    2010-12-01

    To analyze the clinical value of multiple sequences derived from dual-source computed tomography (DSCT) dual-energy scan mode in detecting pancreatic adenocarcinoma. Totally 23 patients with clinically or pathologically diagnosed pancreatic cancer were enrolled in this retrospective study. DSCT (Definition Flash) was used and dual-energy scan mode was used in their pancreatic parenchyma phase scan (100kVp/230mAs and Sn140kVp/178mAs) . Mono-energetic 60kev, mono-energetic 80kev, mono-energetic 100kev, mono-energetic 120kev, linear blend image, non-linear blend image, and iodine map were acquired. pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were calculated. One-way ANOVA was used for the comparison of diagnostic values of the above eight different dual-energy derived sequences for pancreatic cancer. The pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were significantly different among eight sequences (P<0.05) . Mono-energetic 60kev image showed the largest parenchyma-tumor CT value [ (77.53 ± 23.42) HU] , and iodine map showed the lowest tumor/parenchyma enhancement ratio (0.39?0.12) and the largest contrast to noise ratio (4.08 ± 1.46) . Multiple sequences can be derived from dual-energy scan mode with DSCT via multiple post-processing methods. Integration of these sequences may further improve the sensitivity of the multislice spiral CT in the diagnosis of pancreatic cancer.

  5. Continuous 1052, 1064 nm dual-wavelength Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Wang, Xiaozhong; Yuan, Haiyang; Wang, Mingshan; Huang, Wencai

    2016-10-01

    Dual-wavelength lasers are usually obtained through balancing the net gain of the two oscillating lines. Competition between transitions 1052 nm, 1061 nm and 1064 nm is utilized to realize a continuous wave 1052 and 1064 nm dual-wavelength Nd:YAG laser firstly in this paper. A specially designed Fabry-Perot band-pass filter is exploited as output coupler to control the thresholds of the oscillating wavelengths. The maximum power of the dual-wavelength laser is 1.6 W and the slope efficiency is about 10%. The power instability of the output dual-wavelength laser is smaller than ±4% in half an hour. The mechanism presented in this paper may provide a new way to obtain dual-wavelength lasers.

  6. Dual-throat thruster thermal model

    NASA Technical Reports Server (NTRS)

    Ewen, R. L.; Obrien, C. J.; Matthews, L. W.

    1986-01-01

    The dual-throat engine is one of the dual nozzle engine concepts studied for advanced space transportation applications. It provides a thrust change and an in-flight area ratio change through the use of two concentric combustors with their throats arranged in series. Test results are presented for a dual throat thruster burning gaseous oxygen and hydrogen at primary (inner) chamber pressures from 380 to 680 psia. Heat flux profiles were obtained from calorimetric cooling channels in the inner nozzle, outer or secondary chamber and the tip of the inner nozzle. Data were obtained for two nozzle spacings over a chamber pressure ratio (secondary/primary) range of 0.45 to 0.83 with both chambers firing (Mode I). Fluxes near the end of the inner nozzle were significantly higher than in Mode II when only the inner chamber was fired, due to the flow separation and recirculation caused by the back pressure imposed by the secondary chamber. As the pressure ratio increased, these heat fluxes increased and the region of high heat flux relative to Mode II extended farther upstream. The use of the gaseous hydrogen bleed flow in the secondary chamber to control heat fluxes in the primary plume attachment region was investigated in Mode II testing. A thermal model of a dual throat thruster was developed and upgraded using the experimental data.

  7. New Processes for Freeze-Drying in Dual-Chamber Systems.

    PubMed

    Werk, T; Ludwig, I S; Luemkemann, J; Huwyler, J; Mahler, H-C; Haeuser, C R; Hafner, M

    2016-01-01

    Dual-chamber systems can offer self-administration and home care use for lyophilized biologics. Only a few products have been launched in dual-chamber systems so far-presumably due to dual-chamber systems' complex and costly drug product manufacturing process. Within this paper, two improved processes (both based on tray filling technology) for freeze-drying pharmaceuticals in dual-chamber systems are described. Challenges with regards to heat transfer were tackled by (1) performing the freeze-drying step in a needle-down orientation in combination with an aluminum block, or (2) freeze-drying the drug product "externally" in a metal cartridge with subsequent filling of the lyophilized cake into the dual-chamber system. Metal-mediated heat transfer was shown to be efficient in both cases and batch (unit-to-unit) homogeneity with regards to sublimation rate was increased. It was difficult to influence ice crystal size using different methods when in use with an aluminum block due to its heat capacity. Using such a metal carrier implies a large heat capacity leading to relatively small ice crystals. Compared to the established process, drying times were reduced by half using the new processes. The drying time was, however, longer for syringes compared to vials due to the syringe design (long and slim). The differences in drying times were less pronounced for aggressive drying cycles. The proposed processes may help to considerably decrease investment costs into dual-chamber system fill-finish equipment. Dual-chamber syringes offer self-administration and home care use for freeze-dried pharmaceuticals. Only a few products have been launched in dual-chamber syringes so far-presumably due to their complex and costly drug product manufacturing process. In this paper two improved processes for freeze-drying pharmaceuticals in dual-chamber syringes are described. The major challenge of freeze-drying is to transfer heat through a vacuum. The proposed processes cope with this

  8. Aging and the Vulnerability of Speech to Dual Task Demands

    PubMed Central

    Kemper, Susan; Schmalzried, RaLynn; Hoffman, Lesa; Herman, Ruth

    2010-01-01

    Tracking a digital pursuit rotor task was used to measure dual task costs of language production by young and older adults. Tracking performance by both groups was affected by dual task demands: time on target declined and tracking error increased as dual task demands increased from the baseline condition to a moderately demanding dual task condition to a more demanding dual task condition. When dual task demands were moderate, older adults’ speech rate declined but their fluency, grammatical complexity, and content were unaffected. When the dual task was more demanding, older adults’ speech, like young adults’ speech, became highly fragmented, ungrammatical, and incoherent. Vocabulary, working memory, processing speed, and inhibition affected vulnerability to dual task costs: vocabulary provided some protection for sentence length and grammaticality, working memory conferred some protection for grammatical complexity, and processing speed provided some protection for speech rate, propositional density, coherence, and lexical diversity. Further, vocabulary and working memory capacity provided more protection for older adults than for young adults although the protective effect of processing speed was somewhat reduced for older adults as compared to the young adults. PMID:21186917

  9. Dual practice in the health sector: review of the evidence

    PubMed Central

    Ferrinho, Paulo; Van Lerberghe, Wim; Fronteira, Inês; Hipólito, Fátima; Biscaia, André

    2004-01-01

    This paper reports on income generation practices among civil servants in the health sector, with a particular emphasis on dual practice. It first approaches the subject of public–private overlap. Thereafter it focuses on coping strategies in general and then on dual practice in particular. To compensate for unrealistically low salaries, health workers rely on individual coping strategies. Many clinicians combine salaried, public-sector clinical work with a fee-for-service private clientele. This dual practice is often a means by which health workers try to meet their survival needs, reflecting the inability of health ministries to ensure adequate salaries and working conditions. Dual practice may be considered present in most countries, if not all. Nevertheless, there is surprisingly little hard evidence about the extent to which health workers resort to dual practice, about the balance of economic and other motives for doing so, or about the consequences for the proper use of the scarce public resources dedicated to health. In this paper dual practice is approached from six different perspectives: (1) conceptual, regarding what is meant by dual practice; (2) descriptive, trying to develop a typology of dual practices; (3) quantitative, trying to determine its prevalence; (4) impact on personal income, the health care system and health status; (5) qualitative, looking at the reasons why practitioners so frequently remain in public practice while also working in the private sector and at contextual, personal life, institutional and professional factors that make it easier or more difficult to have dual practices; and (6) possible interventions to deal with dual practice. PMID:15509305

  10. Dual Heat Pulse, Dual Layer Thermal Protection System Sizing Analysis and Trade Studies for Human Mars Entry Descent and Landing

    NASA Technical Reports Server (NTRS)

    McGuire, Mary Kathleen

    2011-01-01

    NASA has been recently updating design reference missions for the human exploration of Mars and evaluating the technology investments required to do so. The first of these started in January 2007 and developed the Mars Design Reference Architecture 5.0 (DRA5). As part of DRA5, Thermal Protection System (TPS) sizing analysis was performed on a mid L/D rigid aeroshell undergoing a dual heat pulse (aerocapture and atmospheric entry) trajectory. The DRA5 TPS subteam determined that using traditional monolithic ablator systems would be mass expensive. They proposed a new dual-layer TPS concept utilizing an ablator atop a low thermal conductivity insulative substrate to address the issue. Using existing thermal response models for an ablator and insulative tile, preliminary hand analysis of the dual layer concept at a few key heating points indicated that the concept showed potential to reduce TPS masses and warranted further study. In FY09, the followon Entry, Descent and Landing Systems Analysis (EDL-SA) project continued by focusing on Exploration-class cargo or crewed missions requiring 10 to 50 metric tons of landed payload. The TPS subteam advanced the preliminary dual-layer TPS analysis by developing a new process and updated TPS sizing code to rapidly evaluate mass-optimized, full body sizing for a dual layer TPS that is capable of dual heat pulse performance. This paper describes the process and presents the results of the EDL-SA FY09 dual-layer TPS analyses on the rigid mid L/D aeroshell. Additionally, several trade studies were conducted with the sizing code to evaluate the impact of various design factors, assumptions and margins.

  11. Human Factors Engineering: Current and Emerging Dual-Use Applications

    NASA Technical Reports Server (NTRS)

    Chandlee, G. O.; Goldsberry, B. S.

    1994-01-01

    Human Factors Engineering is a multidisciplinary endeavor in which information pertaining to human characteristics is used in the development of systems and machines. Six representatives considered to be experts from the public and private sectors were surveyed in an effort to identify the potential dual-use of human factors technology. Each individual was asked to provide a rating as to the dual-use of 85 identified NASA technologies. Results of the survey were as follows: nearly 75 percent of the technologies were identified at least once as high dual-use by one of the six survey respondents, and nearly 25 percent of the identified NASA technologies were identified as high dual-use technologies by a majority of the respondents. The perceived level of dual-use appeared to be independent of the technology category. Successful identification of dual-use technology requires expanded input from industry. As an adjunct, cost-benefit analysis should be conducted to identify the feasibility of the dual-use technology. Concurrent with this effort should be an examination of precedents established by other technologies in other industrial settings. Advances in human factors and systems engineering are critical to reduce risk in any workplace and to enhance industrial competitiveness.

  12. Analysis of preservatives with different polarities in beverage samples by dual-phase dual stir bar sorptive extraction combined with high-performance liquid chromatography.

    PubMed

    Xu, Jin; Chen, Beibei; He, Man; Hu, Bin

    2013-02-22

    A new concept of "dual-phase dual stir bar sorptive extraction (SBSE)" was proposed to simultaneously extract six preservatives with different polarities (logKo/w values of 1.27-3.41), namely, benzoic acid (BA), sorbic acid (SA), methyl p-hydroxybenzoate (MP), ethyl p-hydroxybenzoate (EP), propyl p-hydroxybenzoate (PP), and butyl p-hydroxybenzoate (BP). The dual-phase dual SBSE apparatus was consisted of two differently coated stir bars, a 3-aminopropyltriethoxysilane (APTES)-hydroxy-terminated silicone oil (OH-TSO)-coated stir bar that was prepared by sol-gel technique and a C(18) silica (C(18))-polydimethylsiloxane (PDMS)-coated stir bar that was prepared by adhesion. In dual-phase dual SBSE, the two stir bars with different coatings were placed in the same sample solution for the simultaneous extraction of the target analytes with different polarities, and then the bars were desorbed in the same desorption solvent. The extraction performance of the dual-phase dual SBSE for the six preservatives was evaluated by comparing with the conventional SBSE (individual stir bar) with different coatings, including commercial PDMS, homemade PDMS, C(18)-APTES-OH-TSO, APTES-OH-TSO, and C(18)-PDMS. The experimental results showed that the dual-phase dual SBSE had the highest extraction efficiency for the six target preservatives. Based on this fact, a novel method by combining the dual-phase dual SBSE which was consisted of the APTES-OH-TSO-coated and C(18)-PDMS-coated stir bars with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was developed for the simultaneous analysis of six target beverage preservatives in beverages. Under optimal conditions, the limits of detection (LODs) for six target preservatives ranged from 0.6 to 2.7 μgL(-1) with the relative standard deviations (RSDs) of 4.6-9.2% (C(BA,SA)=5 μgL(-1),C(MP)=20 μgL(-1),C(EP,PP,BP)=10 μgL(-1), n=7). The enrichment factors (EFs) were approximately 16-42-fold (theoretical EF was 50-fold

  13. Assimilation of Dual-Polarimetric Radar Observations with WRF GSI

    NASA Technical Reports Server (NTRS)

    Li, Xuanli; Mecikalski, John; Fehnel, Traci; Zavodsky, Bradley; Srikishen, Jayanthi

    2014-01-01

    Dual-polarimetric (dual-pol) radar typically transmits both horizontally and vertically polarized radio wave pulses. From the two different reflected power returns, more accurate estimate of liquid and solid cloud and precipitation can be provided. The upgrade of the traditional NWS WSR-88D radar to include dual-pol capabilities will soon be completed for the entire NEXRAD network. Therefore, the use of dual-pol radar network will have a broad impact in both research and operational communities. The assimilation of dual-pol radar data is especially challenging as few guidelines have been provided by previous research. It is our goal to examine how to best use dual-pol radar data to improve forecast of severe storm and forecast initialization. In recent years, the Development Testbed Center (DTC) has released the community Gridpoint Statistical Interpolation (GSI) DA system for the Weather Research and Forecasting (WRF) model. The community GSI system runs in independently environment, yet works functionally equivalent to operational centers. With collaboration with the NASA Short-term Prediction Research and Transition (SPoRT) Center, this study explores regional assimilation of the dual-pol radar variables from the WSR-88D radars for real case storms. Our presentation will highlight our recent effort on incorporating the horizontal reflectivity (ZH), differential reflectivity (ZDR), specific differential phase (KDP), and radial velocity (VR) data for initializing convective storms, with a significant focus being on an improved representation of hydrometeor fields. In addition, discussion will be provided on the development of enhanced assimilation procedures in the GSI system with respect to dual-pol variables. Beyond the dual-pol variable assimilation procedure developing within a GSI framework, highresolution (=1 km) WRF model simulations and storm scale data assimilation experiments will be examined, emphasizing both model initialization and short-term forecast

  14. [LONG-TERM SURVIVAL OF DUAL DISORDERS PATIENTS AFTER MIXED CARE IN DUAL DISORDERS AND STANDARD WARDS VERSUS CARE ONLY IN DUAL DISORDERS WARD].

    PubMed

    Gimelfarb, Yuri; Wolf, Aviva; Ben-Tzarfati, Mashit

    2017-01-01

    Dual disorders (co-occurring mental illness and substance abuse disorders in the same person) are extremely common among patients receiving mental health services. Integrated treatment has been proposed as the standard of care and it describes a flexible combination of treatments from the mental health and addiction fields that are blended together in the therapy. Scientific evidence for survival of dual disorders patients (DDPs), who had integrated dual disorders inpatient care, is lacking. To determine the long term survival rates following integrated care (Integrated Dual Diagnosis Treatment Ward [IDDTW] only) versus mixed care (IDDTW and psychiatric wards) during the life-time of DDPs. The charts of 333 subjects admitted to IDDTW during the period January 2002 - June 2006 were assessed at least 8 years after the first admission. Psychiatric diagnoses have been established and grouped according to international classification of diseases and health-related problems -10th edition (ICD-10). The Kaplan-Meier survival analysis was used to estimate the cumulative survival rates in all the subpopulations, and the predictive values of different variables were assessed by Cox proportional-hazards regression model. The total all-cause 12-year, unadjusted mortality was 21.1% in integrated care versus 24.6% in mixed care (p<.68). The Cox regression was not revealed for integrated care as a predictive factor for all-cause mortality. The findings showed that there was no consistent evidence to support integrated inpatient care over mixed care, as measured by long-term survival. More studies are required in order to address the challenges posed in the treatment of DDPs.

  15. Differences Between Dual-Method and Non–Dual-Method Protection Use in a Sample of Young African American Women Residing in the Southeastern United States

    PubMed Central

    Sales, Jessica M.; Latham, Teaniese P.; DiClemente, Ralph J.; Rose, Eve

    2013-01-01

    Objectives To characterize dual-method protection users and report the prevalence of dual-method use among young adult African American women residing in the Southeastern United States. Design Analysis of baseline data from a randomized controlled trial. Setting A clinic-based sample of young women enrolled in a randomized trial of a human immunodeficiency virus (HIV)–prevention program in Atlanta, Georgia, from June 2005 to June 2007. Participants African American women aged 14 to 20 years who reported unprotected sexual activity in the past 6months. Of the eligible adolescents, 94% (N=701) were enrolled in the study and completed baseline assessments. Outcome Measures Dual-method protection use as well as sociodemographic, individual-level, interpersonal-level, and community-level factors and interpersonal communication skills. Only data from the baseline assessment, before randomization, were used for the analysis. Results A total of 102 participants (14.6%) were classified as dual-method protection users. After controlling for age and clinic, significant differences between dual-method users and non–dual-method users were found for impulsivity, self-esteem, social support, relationship style, partner communication self-efficacy, and fear of condom negotiation. Conclusions Dual-method protection use is low. Identification of factors that differentiate dual-method users from non–dual-method users at the individual, interpersonal, and community levels in this young African American sample suggests that HIV, sexually transmitted disease, and unintended pregnancy risk–reduction programs should address factors at each level, not simply the individual level, and that this may involve structural and/or clinical counseling practice changes in clinics that serve young women, to optimally facilitate dual-method protection use among young African American women in the Southeastern United States. PMID:21135341

  16. Dual Contraceptive Method Use Among Youth in Alternative Schools.

    PubMed

    Coyle, Karin K; Peterson, Amy J; Franks, Heather M; Anderson, Pamela M; Glassman, Jill R

    2016-12-01

    Dual contraceptive method use, or using a highly effective contraceptive method plus a barrier method like condoms, is gaining attention as a strategy for preventing unplanned pregnancy and sexually transmitted diseases. We investigated rates of dual method use among a sample of youth in urban alternative schools, and explored the relationship between dual method use and sexual partner type. The study analyzed data from 765 students enrolled in 11 district-run continuation high schools in northern California. We explored the association between dual method use and sexual partner type (steady only, a mix of steady and non-steady, and non-steady only) using logistic regression. Differences in dual rates by partner type were statistically significant, with higher rates of dual methods use reported among young people reporting non-steady sexual partners only, as compared to those with steady partners only. The data illustrate that young people in alternative school settings could gain from further intervention on the benefits, skills, and challenges of using two methods of contraception as opposed to one with both steady and non-steady sexual partners.

  17. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Dual voltage generators. 183.324 Section 183.324 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators...

  18. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Dual voltage generators. 183.324 Section 183.324 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators...

  19. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Dual voltage generators. 183.324 Section 183.324 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators...

  20. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Dual voltage generators. 183.324 Section 183.324 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators...

  1. Isogeometric Bézier dual mortaring: Refineable higher-order spline dual bases and weakly continuous geometry

    NASA Astrophysics Data System (ADS)

    Zou, Z.; Scott, M. A.; Borden, M. J.; Thomas, D. C.; Dornisch, W.; Brivadis, E.

    2018-05-01

    In this paper we develop the isogeometric B\\'ezier dual mortar method. It is based on B\\'ezier extraction and projection and is applicable to any spline space which can be represented in B\\'ezier form (i.e., NURBS, T-splines, LR-splines, etc.). The approach weakly enforces the continuity of the solution at patch interfaces and the error can be adaptively controlled by leveraging the refineability of the underlying dual spline basis without introducing any additional degrees of freedom. We also develop weakly continuous geometry as a particular application of isogeometric B\\'ezier dual mortaring. Weakly continuous geometry is a geometry description where the weak continuity constraints are built into properly modified B\\'ezier extraction operators. As a result, multi-patch models can be processed in a solver directly without having to employ a mortaring solution strategy. We demonstrate the utility of the approach on several challenging benchmark problems. Keywords: Mortar methods, Isogeometric analysis, B\\'ezier extraction, B\\'ezier projection

  2. Perceptual Space of Superimposed Dual-Frequency Vibrations in the Hands.

    PubMed

    Hwang, Inwook; Seo, Jeongil; Choi, Seungmoon

    2017-01-01

    The use of distinguishable complex vibrations that have multiple spectral components can improve the transfer of information by vibrotactile interfaces. We investigated the qualitative characteristics of dual-frequency vibrations as the simplest complex vibrations compared to single-frequency vibrations. Two psychophysical experiments were conducted to elucidate the perceptual characteristics of these vibrations by measuring the perceptual distances among single-frequency and dual-frequency vibrations. The perceptual distances of dual-frequency vibrations between their two frequency components along their relative intensity ratio were measured in Experiment I. The estimated perceptual spaces for three frequency conditions showed non-linear perceptual differences between the dual-frequency and single-frequency vibrations. A perceptual space was estimated from the measured perceptual distances among ten dual-frequency compositions and five single-frequency vibrations in Experiment II. The effect of the component frequency and the frequency ratio was revealed in the perceptual space. In a percept of dual-frequency vibration, the lower frequency component showed a dominant effect. Additionally, the perceptual difference among single-frequency and dual-frequency vibrations were increased with a low relative difference between two frequencies of a dual-frequency vibration. These results are expected to provide a fundamental understanding about the perception of complex vibrations to enrich the transfer of information using vibrotactile stimuli.

  3. Implications of dual practice for universal health coverage.

    PubMed

    McPake, Barbara; Russo, Giuliano; Hipgrave, David; Hort, Krishna; Campbell, James

    2016-02-01

    Making progress towards universal health coverage (UHC) requires that health workers are adequate in numbers, prepared for their jobs and motivated to perform. In establishing the best ways to develop the health workforce, relatively little attention has been paid to the trends and implications of dual practice - concurrent employment in public and private sectors. We review recent research on dual practice for its potential to guide staffing policies in relation to UHC. Many studies describe the characteristics and correlates of dual practice and speculate about impacts, but there is very little evidence that is directly relevant to policy-makers. No studies have evaluated the impact of policies on the characteristics of dual practice or implications for UHC. We address this lack and call for case studies of policy interventions on dual practice in different contexts. Such research requires investment in better data collection and greater determination on the part of researchers, research funding bodies and national research councils to overcome the difficulties of researching sensitive topics of health systems functions.

  4. Muscle fat fraction in neuromuscular disorders: dual-echo dual-flip-angle spoiled gradient-recalled MR imaging technique for quantification--a feasibility study.

    PubMed

    Gaeta, Michele; Scribano, Emanuele; Mileto, Achille; Mazziotti, Silvio; Rodolico, Carmelo; Toscano, Antonio; Settineri, Nicola; Ascenti, Giorgio; Blandino, Alfredo

    2011-05-01

    To prospectively evaluate the muscle fat fraction (MFF) measured with dual-echo dual-flip-angle spoiled gradient-recalled acquisition in the steady state (SPGR) magnetic resonance (MR) imaging technique by using muscle biopsy as the reference standard. After ethics approval, written informed consent from all patients was obtained. Twenty-seven consecutive patients, evaluated at the Neuromuscular Disorders Center with a possible diagnosis of neuromuscular disorder, were prospectively studied with MR imaging of the lower extremities to quantify muscle fatty infiltration by means of MFF calculation. Spin-density- and T1-weighted fast SPGR in-phase and opposed-phase dual-echo sequences were performed, respectively, with 20° and 80° flip angles. Round regions of interest were drawn by consensus on selected MR sections corresponding to anticipated biopsy sites. These were marked on the patient's skin with a pen by using the infrared spider light of the system, and subsequent muscle biopsy was performed. MR images with regions of interest were stored on a secondary console where the MFF calculation was performed by another radiologist blinded to the biopsy results. MFFs calculated with dual-echo dual-flip-angle SPGR MR imaging and biopsy were compared by using a paired t test, Pearson correlation coefficient, and Bland-Altman plots. P value of < .05 was considered to indicate a statistically significant difference. The mean MFFs obtained with dual-echo dual-flip-angle SPGR MR imaging and biopsy were 20.3% (range, 1.7%-45.1%) and 20.6% (range, 3%-46.1%), respectively. The mean difference, standard deviation of the difference, and t value were -0.3, 1.3, and -1.3 (P > .2), respectively. The Pearson correlation coefficient was 0.995; with the Bland-Altman method, all data points were within the ± 2 SDs limits of agreement. The results show that dual-echo dual-flip-angle SPGR MR imaging technique provides reliable calculation of MFF, consistent with biopsy measurements

  5. Physician Dual Practice: A Descriptive Mapping Review of Literature.

    PubMed

    Moghri, Javad; Arab, Mohammad; Rashidian, Arash; Akbari Sari, Ali

    2016-03-01

    Physician dual practice is a common phenomenon in almost all countries throughout the world, which could potential impacts on access, equity and quality of services. This paper aims to review studies in physician dual practice and categorize them in order to their main objectives and purposes. Comprehensive literature searches were undertaken in order to obtain main papers and documents in the field of physician dual practice. Systematic searches in Medline and Embase from 1960 to 2013, and general searches in some popular search engines were carried out in this way. After that, descriptive mapping review methods were utilized to categorize eligible studies in this area. The searches obtained 404 titles, of which 81 full texts were assessed. Finally, 24 studies were eligible for inclusion in our review. These studies were categorized into four groups - "motivation and forces behind dual practice", "consequences of dual practice", "dual practice Policies and their impacts", and "other studies" - based on their main objectives. Our findings showed a dearth of scientifically reliable literature in some areas of dual practice, like the prevalence of the phenomenon, the real consequences of it, and the impacts of the implemented policy measures. Rigorous empirical and evaluative studies should be designed to detect the real consequences of DP and assess the effects of interventions and regulations, which governments have implemented in this field.

  6. If Maxwell had worked between Ampère and Faraday: An historical fable with a pedagogical moral

    NASA Astrophysics Data System (ADS)

    Jammer, Max; Stachel, John

    1980-01-01

    If one drops the Faraday induction term from Maxwell's equations, they become exactly Galilei invariant. This suggests that if Maxwell had worked between Ampère and Faraday, he could have developed this Galilei-invariant electromagnetic theory so that Faraday's discovery would have confronted physicists with the dilemma: give up the Galileian relativity principle for electromagnetism (ether hypothesis), or modify it (special relativity). This suggests a new pedagogical approach to electromagnetic theory, in which the displacement current and the Galileian relativity principle are introduced before the induction term is discussed.

  7. Health care utilization among Medicare-Medicaid dual eligibles: a count data analysis.

    PubMed

    Moon, Sangho; Shin, Jaeun

    2006-04-05

    Medicare-Medicaid dual eligibles are the beneficiaries of both Medicare and Medicaid. Dual eligibles satisfy the eligibility conditions for Medicare benefit. Dual eligibles also qualify for Medicaid because they are aged, blind, or disabled and meet the income and asset requirements for receiving Supplement Security Income (SSI) assistance. The objective of this study is to explore the relationship between dual eligibility and health care utilization among Medicare beneficiaries. The household component of the nationally representative Medical Expenditure Panel Survey (MEPS) 1996-2000 is used for the analysis. Total 8,262 Medicare beneficiaries are selected from the MEPS data. The Medicare beneficiary sample includes individuals who are covered by Medicare and do not have private health insurance during a given year. Zero-inflated negative binomial (ZINB) regression model is used to analyse the count data regarding health care utilization: office-based physician visits, hospital inpatient nights, agency-sponsored home health provider days, and total dental visits. Dual eligibility is positively correlated with the likelihood of using hospital inpatient care and agency-sponsored home health services and the frequency of agency-sponsored home health days. Frequency of dental visits is inversely associated with dual eligibility. With respect to racial differences, dually eligible Afro-Americans use more office-based physician and dental services than white duals. Asian duals use more home health services than white duals at the 5% statistical significance level. The dual eligibility programs seem particularly beneficial to Afro-American duals. Dual eligibility has varied impact on health care utilization across service types. More utilization of home healthcare among dual eligibles appears to be the result of delayed realization of their unmet healthcare needs under the traditional Medicare-only program rather than the result of overutilization in response to the

  8. Dual porosity gas evolving electrode

    DOEpatents

    Townsend, C.W.

    1994-11-15

    A dual porosity electrode is described for use in thermoelectrochemical systems where simultaneous transport of gas and liquid into and/or out of the electrode is required. The electrode includes catalytic electrode particles having diameters ranging from about 25 to 100 angstroms. The catalytic electrode particles are anchored to a support network in clusters which have internal pores ranging in size from 25 to 100 angstroms. The pores between the clusters range in size from between about 1 to 20 microns. A method for making the dual porosity electrodes is also disclosed.

  9. Dual porosity gas evolving electrode

    DOEpatents

    Townsend, Carl W.

    1994-01-01

    A dual porosity electrode for use in thermoelectrochemical systems where simultaneous transport of gas and liquid into and/or out of the electrode is required. The electrode includes catalytic electrode particles having diameters ranging from about 25 to 100 angstroms. The catalytic electrode particles are anchored to a support network in clusters which have internal pores ranging in size from 25 to 100 angstroms. The pores between the clusters range in size from between about 1 to 20 microns. A method for making the dual porosity electrodes is also disclosed.

  10. 92 GHz dual-polarized integrated horn antennas

    NASA Technical Reports Server (NTRS)

    Ali-Ahmad, Walid Y.; Rebeiz, Gabriel M.

    1991-01-01

    A dual-polarized two-dimensional imaging array was designed for millimeter-wave applications. The dual-polarized design consists of two dipoles perpendicular to each other and suspended on the same membrane inside a pyramidal cavity etched in silicon. The dual-polarized antenna is fully monolithic with room available for processing electronics. The IF or video signals are taken out through a novel bias and feeding structure. The measured polarization isolation is better than 20 dB at 92 GHz, and the orthogonal channels show identical far-field patterns. The antenna is well suited for millimeter-wave polarimetric synthetic-aperture radars (SARs) and high-efficiency balanced-mixer receivers.

  11. Truncated Dual-Cap Nucleation Site Development

    NASA Technical Reports Server (NTRS)

    Matson, Douglas M.; Sander, Paul J.

    2012-01-01

    During heterogeneous nucleation within a metastable mushy-zone, several geometries for nucleation site development must be considered. Traditional spherical dual cap and crevice models are compared to a truncated dual cap to determine the activation energy and critical cluster growth kinetics in ternary Fe-Cr-Ni steel alloys. Results of activation energy results indicate that nucleation is more probable at grain boundaries within the solid than at the solid-liquid interface.

  12. Immigrants and Suffrage: Adding to the Discourse by Integrating State versus National Citizenship, Dual Domestic Residency, and Dual Citizenship

    ERIC Educational Resources Information Center

    Garcia, John A.

    2012-01-01

    This article builds upon the literature on immigrants and the vote by focusing on three legal and democratic principles: state versus national citizenship, dual domestic residency, and globalization/dual citizenship. It first delineates the discretion and powers that states can utilize to establish suffrage rights. The article next develops…

  13. Postmortem validation of breast density using dual-energy mammography

    PubMed Central

    Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.

    2014-01-01

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer. PMID:25086548

  14. Postmortem validation of breast density using dual-energy mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molloi, Sabee, E-mail: symolloi@uci.edu; Ducote, Justin L.; Ding, Huanjun

    2014-08-15

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decompositionmore » was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.« less

  15. The neural architecture of age-related dual-task interferences.

    PubMed

    Chmielewski, Witold X; Yildiz, Ali; Beste, Christian

    2014-01-01

    In daily life elderly adults exhibit deficits when dual-tasking is involved. So far these deficits have been verified on a behavioral level in dual-tasking. Yet, the neuronal architecture of these deficits in aging still remains to be explored especially when late-middle aged individuals around 60 years of age are concerned. Neuroimaging studies in young participants concerning dual-tasking were, among others, related to activity in middle frontal (MFG) and superior frontal gyrus (SFG) and the anterior insula (AI). According to the frontal lobe hypothesis of aging, alterations in these frontal regions (i.e., SFG and MFG) might be responsible for cognitive deficits. We measured brain activity using fMRI, while examining age-dependent variations in dual-tasking by utilizing the PRP (psychological refractory period) test. Behavioral data showed an increasing PRP effect in late-middle aged adults. The results suggest the age-related deteriorated performance in dual-tasking, especially in conditions of risen complexity. These effects are related to changes in networks involving the AI, the SFG and the MFG. The results suggest that different cognitive subprocesses are affected that mediate the observed dual-tasking problems in late-middle aged individuals.

  16. Economic Efficiency and Investment Timing for Dual Water Systems

    NASA Astrophysics Data System (ADS)

    Leconte, Robert; Hughes, Trevor C.; Narayanan, Rangesan

    1987-10-01

    A general methodology to evaluate the economic feasibility of dual water systems is presented. In a first step, a static analysis (evaluation at a single point in time) is developed. The analysis requires the evaluation of consumers' and producer's surpluses from water use and the capital cost of the dual (outdoor) system. The analysis is then extended to a dynamic approach where the water demand increases with time (as a result of a population increase) and where the dual system is allowed to expand. The model determines whether construction of a dual system represents a net benefit, and if so, what is the best time to initiate the system (corresponding to maximization of social welfare). Conditions under which an analytic solution is possible are discussed and results of an application are summarized (including sensitivity to different parameters). The analysis allows identification of key parameters influencing attractiveness of dual water systems.

  17. Coherent cavity-enhanced dual-comb spectroscopy.

    PubMed

    Fleisher, Adam J; Long, David A; Reed, Zachary D; Hodges, Joseph T; Plusquellic, David F

    2016-05-16

    Dual-comb spectroscopy allows for the rapid, multiplexed acquisition of high-resolution spectra without the need for moving parts or low-resolution dispersive optics. This method of broadband spectroscopy is most often accomplished via tight phase locking of two mode-locked lasers or via sophisticated signal processing algorithms, and therefore, long integration times of phase coherent signals are difficult to achieve. Here we demonstrate an alternative approach to dual-comb spectroscopy using two phase modulator combs originating from a single continuous-wave laser capable of > 2 hours of coherent real-time averaging. The dual combs were generated by driving the phase modulators with step-recovery diodes where each comb consisted of > 250 teeth with 203 MHz spacing and spanned > 50 GHz region in the near-infrared. The step-recovery diodes are passive devices that provide low-phase-noise harmonics for efficient coupling into an enhancement cavity at picowatt optical powers. With this approach, we demonstrate the sensitivity to simultaneously monitor ambient levels of CO2, CO, HDO, and H2O in a single spectral region at a maximum acquisition rate of 150 kHz. Robust, compact, low-cost and widely tunable dual-comb systems could enable a network of distributed multiplexed optical sensors.

  18. Dual AAV Vectors for Stargardt Disease.

    PubMed

    Trapani, Ivana

    2018-01-01

    Stargardt disease (STGD1), due to mutations in the large ABCA4 gene, is the most common inherited macular degeneration in humans. Attempts at developing gene therapy approaches for treatment of STGD1 are currently ongoing. Among all the vectors available for gene therapy of inherited retinal diseases, those based on adeno-associated viruses (AAV) are the most promising given the efficacy shown in various animal models and their excellent safety profile in humans, as confirmed in many ongoing clinical trials. However, one of the main obstacles for the use of AAV is their limited effective packaging capacity of about 5 kb. Taking advantage of the AAV genome's ability to concatemerize , others and we have recently developed dual AAV vectors to overcome this limit. We tested dual AAV vectors for ABCA4 delivery, and found that they transduce efficiently both mouse and pig photoreceptors , and rescue the Abca4-/- mouse retinal phenotype, indicating their potential for gene therapy of STGD1. This chapter details how we designed dual AAV vectors for the delivery of the ABCA4 gene and describes the techniques that can be explored to evaluate dual AAV transduction efficiency in vitro and in the retina, and their efficacy in the mouse model of STGD1.

  19. Coherent cavity-enhanced dual-comb spectroscopy

    PubMed Central

    Fleisher, Adam J.; Long, David A.; Reed, Zachary D.; Hodges, Joseph T.; Plusquellic, David F.

    2016-01-01

    Dual-comb spectroscopy allows for the rapid, multiplexed acquisition of high-resolution spectra without the need for moving parts or low-resolution dispersive optics. This method of broadband spectroscopy is most often accomplished via tight phase locking of two mode-locked lasers or via sophisticated signal processing algorithms, and therefore, long integration times of phase coherent signals are difficult to achieve. Here we demonstrate an alternative approach to dual-comb spectroscopy using two phase modulator combs originating from a single continuous-wave laser capable of > 2 hours of coherent real-time averaging. The dual combs were generated by driving the phase modulators with step-recovery diodes where each comb consisted of > 250 teeth with 203 MHz spacing and spanned > 50 GHz region in the near-infrared. The step-recovery diodes are passive devices that provide low-phase-noise harmonics for efficient coupling into an enhancement cavity at picowatt optical powers. With this approach, we demonstrate the sensitivity to simultaneously monitor ambient levels of CO2, CO, HDO, and H2O in a single spectral region at a maximum acquisition rate of 150 kHz. Robust, compact, low-cost and widely tunable dual-comb systems could enable a network of distributed multiplexed optical sensors. PMID:27409866

  20. Dual Credit: Creating Career and Work Possibilities for Canadian Youth

    ERIC Educational Resources Information Center

    Watt-Malcolm, Bonnie

    2011-01-01

    In this article, I investigated the problems that educators are addressing with dual credit initiatives and consider tensions that have limited the seamless implementation of dual credit programming. Stakeholder representatives clearly identified common resources and support required to sustain their dual credit programs. Study participants noted…

  1. Formation of Offset and Dual Active Galactic Nuclei

    NASA Astrophysics Data System (ADS)

    Barrows, Scott; Comerford, Julia M.; Greene, Jenny E.

    2018-06-01

    Galaxy mergers are effective mechanisms for triggering accretion onto supermassive black holes (SMBHs) and thereby powering active galactic nuclei (AGN). In the merger scenario, when the SMBH from only one galaxy is accreting we observe a spatially offset AGN, and when the SMBHs from both galaxies are accreting we observe a dual AGN. Understanding the merger conditions that lead to the formation of offset AGN versus dual AGN is fundamental to informing models of hierarchical SMBH growth and the physics leading to the accretion of matter onto SMBHs. However, while the role of galaxy mergers for AGN triggering has been well-studied, the efficiency with which these events trigger offset AGN versus dual AGN is currently unclear. One reason for this gap in knowledge can be attributed to the observational difficulties in distinguishing between offset and dual AGN since doing so requires high spatial resolution, especially in the small separation regime where merger-driven AGN triggering is most likely to occur. To overcome this hurdle, we have utilized the spatial resolution of the Chandra X-ray Observatory to develop a unique sample of AGN hosted by late-stage galaxy mergers. Moreover, we have recently acquired Hubble Space Telescope imaging for a subset of these systems to examine the role that their merger morphologies play in SMBH growth and the formation of offset and dual AGN. We find that offset AGN are predominately found in minor mergers, whereas dual AGN are usually hosted by major mergers and galaxies with large morphological asymmetries. Furthermore, in both offset and dual AGN, the rate of SMBH growth increases toward more major mergers and larger morphological asymmetries. These results are in agreement with numerical simulations predicting that merger morphology is a relevant parameter governing SMBH merger-driven growth, and these results are the first to observationally confirm these trends at small pair separations.

  2. Adolescents and Dual Diagnosis in a Psychiatric Emergency Service.

    PubMed

    Matali, José Luis; Andión, Oscar; Pardo, Marta; Iniesta, Raquel; Serrano, Eduard; San, Luis

    2016-03-02

    In recent years, both the prevalence of drug use and related child and adolescent psychiatric emergencies have risen sharply. There are few studies about the impact on child and adolescent emergency services. This study has a twofold aim. The first is to describe the prevalence of substance use disorders, mental disorders and dual diagnosis (substance use problems plus mental disorder) in adolescents in psychiatric emergency service. The second is to analyze clinical and healthcare differences between patients with dual diagnosis and patients with a mental disorder without substance use disorder.We retrospectively reviewed 4012 discharge forms for emergencies treated at the psychiatric emergency department during the period 2007-2009. We obtained a sample of 1795 visits. This sample was divided into two groups: the dual diagnosis group (n = 477) and the psychiatric disorder group (n = 1318).The dual diagnosis group accounted for 26.5% of psychiatric emergencies analyzed. Compared to the psychiatric disorder group,the dual diagnosis group had significantly more conduct disorders, social problems, involuntariness in the visit, less hospital admissions and less connection with the healthcare network.Adolescents with a dual diagnosis account for a high percentage of visits at child and adolescent psychiatric emergency services. This patient group requires specialized care both at emergency services and in specific units. Accordingly, these units should play a triple role when handling dual diagnosis: detection, brief treatment and referral to a specialised unit.

  3. Dual Learning Processes in Interactive Skill Acquisition

    ERIC Educational Resources Information Center

    Fu, Wai-Tat; Anderson, John R.

    2008-01-01

    Acquisition of interactive skills involves the use of internal and external cues. Experiment 1 showed that when actions were interdependent, learning was effective with and without external cues in the single-task condition but was effective only with the presence of external cues in the dual-task condition. In the dual-task condition, actions…

  4. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy

    NASA Astrophysics Data System (ADS)

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  5. Dual-Chamber/Dual-Anode Proportional Counter Incorporating an Intervening Thin-Foil Solid Neutron Converter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boatner, Lynn A; Neal, John S; Blackston, Matthew A

    2012-01-01

    A dual-chamber/dual-anode gas proportional counter utilizing thin solid 6LiF or 10B neutron converters coated on a 2-micon-thick Mylar film that is positioned between the two counter chambers and anodes has been designed, fabricated, and tested using a variety of fill gases including naturally abundant helium. In this device, neutron conversion products emitted from both sides of the coated converter foil are detected rather than having half of the products absorbed in the wall of a conventional tube type counter where the solid neutron converter is deposited on the tube wall. Geant4-based radiation transport calculations were used to determine the optimummore » neutron converter coating thickness for both isotopes. Solution methods for applying these optimized-thickness coatings on a Mylar film were developed that were carried out at room temperature without any specialized equipment and that can be adapted to standard coating methods such as silk screen or ink jet printing. The performance characteristics of the dual-chamber/dual-anode neutron detector were determined for both types of isotopically enriched converters. The experimental performance of the 6LiF converter-based detector was described well by modeling results from Geant4. Additional modeling studies of multiple-foil/multiple-chamber/anode configurations addressed the basic issue of the relatively longer absorption range of neutrons versus the shorter range of the conversion products for 6LiF and 10B. Combined with the experimental results, these simulations indicate that a high-performance neutron detector can be realized in a single device through the application of these multiple-foil/solid converter, multiple-chamber detector concepts.« less

  6. Longitudinal effects of bilingualism on dual-tasking

    PubMed Central

    Josefsson, Maria; Marsh, John E.; Hansson, Patrik; Ljungberg, Jessica K.

    2017-01-01

    An ongoing debate surrounds whether bilinguals outperform monolinguals in tests of executive processing. The aim of this study was to investigate if there are long-term (10 year) bilingual advantages in executive processing, as indexed by dual-task performance, in a sample that were 40–65 years at baseline. The bilingual (n = 24) and monolingual (n = 24) participants were matched on age, sex, education, fluid intelligence, and study sample. Participants performed free-recall for a 12-item list in three dual-task settings wherein they sorted cards either during encoding, retrieval, or during both encoding and retrieval of the word-list. Free recall without card sorting was used as a reference to compute dual-task costs. The results showed that bilinguals significantly outperformed monolinguals when they performed card-sorting during both encoding and retrieval of the word-list, the condition that presumably placed the highest demands on executive functioning. However, dual-task costs increased over time for bilinguals relative to monolinguals, a finding that is possibly influenced by retirement age and limited use of second language in the bilingual group. PMID:29281654

  7. 20 CFR 225.13 - Social Security Earnings Dual Benefit PIA.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false Social Security Earnings Dual Benefit PIA... Spouse Annuities § 225.13 Social Security Earnings Dual Benefit PIA. (a) General. The Social Security... certain eligibility requirements as described in part 216 of this chapter. The Social Security Dual...

  8. 20 CFR 225.13 - Social Security Earnings Dual Benefit PIA.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 1 2014-04-01 2012-04-01 true Social Security Earnings Dual Benefit PIA. 225... Spouse Annuities § 225.13 Social Security Earnings Dual Benefit PIA. (a) General. The Social Security... certain eligibility requirements as described in part 216 of this chapter. The Social Security Dual...

  9. 20 CFR 225.13 - Social Security Earnings Dual Benefit PIA.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 1 2013-04-01 2012-04-01 true Social Security Earnings Dual Benefit PIA. 225... Spouse Annuities § 225.13 Social Security Earnings Dual Benefit PIA. (a) General. The Social Security... certain eligibility requirements as described in part 216 of this chapter. The Social Security Dual...

  10. 20 CFR 225.13 - Social Security Earnings Dual Benefit PIA.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 1 2012-04-01 2012-04-01 false Social Security Earnings Dual Benefit PIA... Spouse Annuities § 225.13 Social Security Earnings Dual Benefit PIA. (a) General. The Social Security... certain eligibility requirements as described in part 216 of this chapter. The Social Security Dual...

  11. 20 CFR 225.13 - Social Security Earnings Dual Benefit PIA.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Social Security Earnings Dual Benefit PIA... Spouse Annuities § 225.13 Social Security Earnings Dual Benefit PIA. (a) General. The Social Security... certain eligibility requirements as described in part 216 of this chapter. The Social Security Dual...

  12. Working Memory Training Improves Dual-Task Performance on Motor Tasks.

    PubMed

    Kimura, Takehide; Kaneko, Fuminari; Nagahata, Keita; Shibata, Eriko; Aoki, Nobuhiro

    2017-01-01

    The authors investigated whether working memory training improves motor-motor dual-task performance consisted of upper and lower limb tasks. The upper limb task was a simple reaction task and the lower limb task was an isometric knee extension task. 45 participants (age = 21.8 ± 1.6 years) were classified into a working memory training group (WM-TRG), dual-task training group, or control group. The training duration was 2 weeks (15 min, 4 times/week). Our results indicated that working memory capacity increased significantly only in the WM-TRG. Dual-task performance improved in the WM-TRG and dual-task training group. Our study provides the novel insight that working memory training improves dual-task performance without specific training on the target motor task.

  13. When parsimony is not enough: Considering dual processes and dual levels of influence in sexual decision making

    PubMed Central

    Rendina, H. Jonathon

    2015-01-01

    The literature on sexual decision making that has been used to understand behaviors relevant to HIV and STI risk has relied primarily on cognitive antecedents of behavior. In contrast, several prominent models of decision making outside of the sexual behavior literature rely on dual process models, in which both affective and cognitive processing are considered important precursors to behavior. Moreover, much of the literature on sexual behavior utilizes individual-level traits and characteristics to predict aggregated sexual behavior, despite decision making itself being a situational or event-level process. This paper proposes a framework for understanding sexual decision making as the result of dual processes (affective and cognitive) operating at dual level of influence (individual and situational). Finally, the paper ends with a discussion of the conceptual and methodological benefits and challenges to its use and future directions for research. PMID:26168978

  14. Dual-Phase Nozzle Flow.

    DTIC Science & Technology

    1982-10-01

    peowti ulliy klei =PodUaWU THESIS DUAL-PHASE NO ZZL FLOW :hcras C. Holi. Jr. Oco’ber 934’ Thesis Advisor: J. F. SlIj=kv Ap:roved _"o~r :zubiic releasc...REPORT NUMBER ILGOVT ACCESSION NO. I. MECIP1EMYS CATALOG NUNSI 3 A. TTLE Old WIM110)S. TYPE or mrEowR A PERIOD COVERED Master’s Thesis ; Dual-Phase Nozzle...ALPUS , Aml A As AT , ’A rF2 fl’Q 2 05 dETAS 181 T AM Si. T 1 AS J!’𔃻 3 c * I CA,; I CA ;A a ZA c1. 1 B SL z.1J 4 CBG1 *CAL *CASE * b. a C𔃾 ; -* U.9 CC

  15. Accuracy of Dual-Energy Virtual Monochromatic CT Numbers: Comparison between the Single-Source Projection-Based and Dual-Source Image-Based Methods.

    PubMed

    Ueguchi, Takashi; Ogihara, Ryota; Yamada, Sachiko

    2018-03-21

    To investigate the accuracy of dual-energy virtual monochromatic computed tomography (CT) numbers obtained by two typical hardware and software implementations: the single-source projection-based method and the dual-source image-based method. A phantom with different tissue equivalent inserts was scanned with both single-source and dual-source scanners. A fast kVp-switching feature was used on the single-source scanner, whereas a tin filter was used on the dual-source scanner. Virtual monochromatic CT images of the phantom at energy levels of 60, 100, and 140 keV were obtained by both projection-based (on the single-source scanner) and image-based (on the dual-source scanner) methods. The accuracy of virtual monochromatic CT numbers for all inserts was assessed by comparing measured values to their corresponding true values. Linear regression analysis was performed to evaluate the dependency of measured CT numbers on tissue attenuation, method, and their interaction. Root mean square values of systematic error over all inserts at 60, 100, and 140 keV were approximately 53, 21, and 29 Hounsfield unit (HU) with the single-source projection-based method, and 46, 7, and 6 HU with the dual-source image-based method, respectively. Linear regression analysis revealed that the interaction between the attenuation and the method had a statistically significant effect on the measured CT numbers at 100 and 140 keV. There were attenuation-, method-, and energy level-dependent systematic errors in the measured virtual monochromatic CT numbers. CT number reproducibility was comparable between the two scanners, and CT numbers had better accuracy with the dual-source image-based method at 100 and 140 keV. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. UWB dual burst transmit driver

    DOEpatents

    Dallum, Gregory E [Livermore, CA; Pratt, Garth C [Discovery Bay, CA; Haugen, Peter C [Livermore, CA; Zumstein, James M [Livermore, CA; Vigars, Mark L [Livermore, CA; Romero, Carlos E [Livermore, CA

    2012-04-17

    A dual burst transmitter for ultra-wideband (UWB) communication systems generates a pair of precisely spaced RF bursts from a single trigger event. An input trigger pulse produces two oscillator trigger pulses, an initial pulse and a delayed pulse, in a dual trigger generator. The two oscillator trigger pulses drive a gated RF burst (power output) oscillator. A bias driver circuit gates the RF output oscillator on and off and sets the RF burst packet width. The bias driver also level shifts the drive signal to the level that is required for the RF output device.

  17. 46 CFR 111.05-29 - Dual voltage direct current systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Dual voltage direct current systems. Each dual voltage direct current system must have a suitably sensitive ground detection system which indicates current in the ground connection, has a range of at least... 46 Shipping 4 2010-10-01 2010-10-01 false Dual voltage direct current systems. 111.05-29 Section...

  18. 46 CFR 111.05-29 - Dual voltage direct current systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Dual voltage direct current systems. Each dual voltage direct current system must have a suitably sensitive ground detection system which indicates current in the ground connection, has a range of at least... 46 Shipping 4 2011-10-01 2011-10-01 false Dual voltage direct current systems. 111.05-29 Section...

  19. Dual redundant arm system operational quality measures and their applications - Dynamic measures

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan; Kim, Sungbok

    1990-01-01

    Dual-arm dynamic operation quality measures are presented which quantify the efficiency and capability of generating Cartesian accelerations by two cooperative arms based on the analysis of dual-arm dynamic interactions. Dual-arm dynamic manipulability is defined as the efficiency of generating Cartesian accelerations under the dynamic and kinematic interactions between individual arms and an object under manipulation. The analysis of dual-arm dynamic interactions is based on the so-called Cartesian space agent model of an arm, which represents an individual arm as a force source acting upon a point mass with the effective Cartesian space arm dynamics and an environment or an object under manipulation. The Cartesian space agent model of an arm makes it possible to derive the dynamic and kinematic constraints involved in the transport, assembly and grasping modes of dual-arm cooperation. A task-oriented operational quality measure, (TOQd) is defined by evaluating dual-arm dynamic manipulability in terms of given task requirements. TOQd is used in dual-arm joint configuration optimization. Simulation results are shown. A complete set of forward dynamic equations for a dual-arm system is derived, and dual-arm dynamic operational quality measures for various modes of dual-arm cooperation allowing sliding contacts are established.

  20. On the dual equivalence of the self-dual and topologically massive /B∧F models coupled to dynamical fermionic matter

    NASA Astrophysics Data System (ADS)

    Menezes, R.; Nascimento, J. R. S.; Ribeiro, R. F.; Wotzasek, C.

    2002-06-01

    We study the equivalence between the /B∧F self-dual (SDB∧F) and the /B∧F topologically massive (TMB∧F) models including the coupling to dynamical, U(1) charged fermionic matter. This is done through an iterative procedure of gauge embedding that produces the dual mapping. In the interactive cases, the minimal coupling adopted for both vector and tensor fields in the self-dual representation is transformed into a non-minimal magnetic like coupling in the topologically massive representation but with the currents swapped. It is known that to establish this equivalence a current-current interaction term is needed to render the matter sector unchanged. We show that both terms arise naturally from the embedding procedure.

  1. Fringe formation in dual-hologram interferometry

    NASA Technical Reports Server (NTRS)

    Burner, A. W.

    1990-01-01

    Reference-fringe formation in nondiffuse dual-hologram interferometry is described by combining a first-order geometrical hologram treatment with interference fringes generated by two point sources. The first-order imaging relationships can be used to describe reference-fringe patterns for the geometry of the dual-hologram interferometry. The process can be completed without adjusting the two holograms when the reconstructing wavelength is less than the exposing wavelength, and the process is found to facilitate basic intereferometer adjustments.

  2. Dual-gate GaAs FET switches

    NASA Astrophysics Data System (ADS)

    Vorhaus, J. L.; Fabian, W.; Ng, P. B.; Tajima, Y.

    1981-02-01

    A set of multi-pole, multi-throw switch devices consisting of dual-gate GaAs FET's is described. Included are single-pole, single-throw (SPST), double-pole, double-throw (DPDT), and single-pole four-throw (SP4T) switches. Device fabrication and measurement techniques are discussed. The device models for these switches were based on an equivalent circuit of a dual-gate FET. The devices were found to have substantial gain in X-band and low Ku-band.

  3. Behavioral Assessment of Listening Effort Using a Dual-Task Paradigm.

    PubMed

    Gagné, Jean-Pierre; Besser, Jana; Lemke, Ulrike

    2017-01-01

    Published investigations ( n = 29) in which a dual-task experimental paradigm was employed to measure listening effort during speech understanding in younger and older adults were reviewed. A summary of the main findings reported in the articles is provided with respect to the participants' age-group and hearing status. Effects of different signal characteristics, such as the test modality, on dual-task outcomes are evaluated, and associations with cognitive abilities and self-report measures of listening effort are described. Then, several procedural issues associated with the use of dual-task experiment paradigms are discussed. Finally, some issues that warrant future research are addressed. The review revealed large variability in the dual-task experimental paradigms that have been used to measure the listening effort expended during speech understanding. The differences in experimental procedures used across studies make it difficult to draw firm conclusions concerning the optimal choice of dual-task paradigm or the sensitivity of specific paradigms to different types of experimental manipulations. In general, the analysis confirmed that dual-task paradigms have been used successfully to measure differences in effort under different experimental conditions, in both younger and older adults. Several research questions that warrant further investigation in order to better understand and characterize the intricacies of dual-task paradigms were identified.

  4. Behavioral Assessment of Listening Effort Using a Dual-Task Paradigm

    PubMed Central

    Besser, Jana; Lemke, Ulrike

    2017-01-01

    Published investigations (n = 29) in which a dual-task experimental paradigm was employed to measure listening effort during speech understanding in younger and older adults were reviewed. A summary of the main findings reported in the articles is provided with respect to the participants’ age-group and hearing status. Effects of different signal characteristics, such as the test modality, on dual-task outcomes are evaluated, and associations with cognitive abilities and self-report measures of listening effort are described. Then, several procedural issues associated with the use of dual-task experiment paradigms are discussed. Finally, some issues that warrant future research are addressed. The review revealed large variability in the dual-task experimental paradigms that have been used to measure the listening effort expended during speech understanding. The differences in experimental procedures used across studies make it difficult to draw firm conclusions concerning the optimal choice of dual-task paradigm or the sensitivity of specific paradigms to different types of experimental manipulations. In general, the analysis confirmed that dual-task paradigms have been used successfully to measure differences in effort under different experimental conditions, in both younger and older adults. Several research questions that warrant further investigation in order to better understand and characterize the intricacies of dual-task paradigms were identified. PMID:28091178

  5. Physical analysis of breast cancer using dual-source computed tomography

    NASA Astrophysics Data System (ADS)

    Kim, H. J.; Lee, H. K.; Cho, J. H.

    2014-12-01

    This study was aimed to analyze various physical characteristics of breast cancer using dual-source computed tomography (CT). A phantom study and a clinical trial were performed in order and a 64-multidetector CT device was used for the examinations. In the phantom study, single-source (SS) CT was set up with a conventional scanning condition that is usually applied for breast CT examination and implementation was done at tube voltage of 120 kVp. Dual-source CT acquired images by irradiating X-ray sources with fast switching between two kilovoltage settings (80 and 140 kVp). After scanning, Hounsfield Unit (HU) values and radiation doses in a region of interest were measured and analyzed. In the clinical trial, the HU values were measured and analyzed after single-source computed tomography (SSCT) and dual-source CT in patients diagnosed with breast cancer. Also, the tumor size measured by dual-source CT was compared with the actual tumor size. The phantom study determined that the tumor region was especially measured by dual-source CT, while nylon fiber and specks region were especially measured by SSCT. The radiation dose was high with dual-source CT. The clinical trial showed a higher HU value of cancerous regions when scanned by dual-source CT compared with SSCT.

  6. N = (2,0) self-dual non-Abelian tensor multiplet in D = 3 + 3 generates N = (1,1) self-dual systems in D = 2 + 2

    NASA Astrophysics Data System (ADS)

    Nishino, Hitoshi; Rajpoot, Subhash

    2018-03-01

    We formulate an N = (2 , 0) system in D = 3 + 3 dimensions consisting of a Yang-Mills (YM)-multiplet (ˆ μ ˆ IA, λˆI), a self-dual non-Abelian tensor multiplet (ˆ μ ˆ ν ˆ IB, χˆI ,φˆI), and an extra vector multiplet (C ˆ μ ˆ IC, ρˆI). We next perform the dimensional reductions of this system into D = 2 + 2, and obtain N = (1 , 1) systems with a self-dual YM-multiplet (AIμ ,λI), a self-dual tensor multiplet (BIμν , χI , φI), and an extra vector multiplet (CIμ , ρI). In D = 2 + 2, we reach two distinct theories: 'Theory-I' and 'Theory-II'. The former has the self-dual field-strength Hμν(+)I of CIμ already presented in our recent paper, while the latter has anti-self-dual field strength Hμν(-)I. As an application, we show that Theory-II actually generates supersymmetric-KdV equations in D = 1 + 1. Our result leads to a new conclusion that the D = 3 + 3 theory with non-Abelian tensor multiplet can be a 'Grand Master Theory' for self-dual multiplet and self-dual YM-multiplet in D = 2 + 2, that in turn has been conjectured to be the 'Master Theory' for all supersymmetric integrable theories in D ≤ 3.

  7. Philosophical aspects of dual use technologies.

    PubMed

    Pustovit, Svitlana V; Williams, Erin D

    2010-03-01

    The term dual use technologies refers to research and technology with the potential both to yield valuable scientific knowledge and to be used for nefarious purposes with serious consequences for public health or the environment. There are two main approaches to assessing dual use technologies: pragmatic and metaphysical. A pragmatic approach relies on ethical principles and norms to generate specific guidance and policy for dual use technologies. A metaphysical approach exhorts us to the deeper study of human nature, our intentions, goals, values ideals and social relations when considering dual use technology. Use of science and technology (S and T) is determined by two components of human nature: human intentions and choices. We have drawn a distinction between specific measures, goals and intentions with respect to technologies in order to show that moral judgment about technologies must precede their use. Understanding of our intentionality and values, and our moral ideals, as a measurable, tangible part of the real world is important for the prevention of any possible harm from S and T. In the context of dual use technologies, we stress the importance of three main understandings of human nature: vulnerability, responsibility and narrative identity. These can become a strong ontological "antidote" to technology's poisoning of modern man. Each new technology can be measured and compared with man's values, traditions and societal norms. This can be done bearing in mind the concept that human nature is not dualistic, but pluralistic. A system of ethical principles that includes the principles of good intentions, the correspondence of goals and means, the balancing of risks and benefits, simplicity, and contextuality, will help ensure that technologies are more humanistic and friendly to human beings.

  8. A Case Study of Dual Language Program Administrators: The Teachers We Need

    ERIC Educational Resources Information Center

    Lachance, Joan R.

    2017-01-01

    In support of growing numbers of dual language programs nation-wide, dual language school administrators seek to find teachers who are specifically prepared to work with dual language learners for additive biliteracy. For this research the author utilized a case study design to explore practicing dual language administrators' perspectives…

  9. Dual-mode capability for hardware-in-the-loop

    NASA Astrophysics Data System (ADS)

    Vamivakas, A. N.; Jackson, Ron L.

    2000-07-01

    This paper details a Hardware-in-the-Loop Facility (HIL) developed for evaluation and verification of a missile system with dual mode capability. The missile has the capability of tracking and intercepting a target using either an RF antenna or an IR sensor. The testing of a dual mode system presents a significant challenge in the development of the HIL facility. An IR and RF target environment must be presented simultaneously to the missile under test. These targets, simulated by IR and RF sources, must be presented to the missile under test without interference from each other. The location of each source is critical in the development of the HIL facility. The requirements for building a HIL facility with dual mode capability and the methodology for testing the dual mode system are defined within this paper. Methods for the verification and validation of the facility are discussed.

  10. The dilemma of dual use biological research: Polish perspective.

    PubMed

    Czarkowski, Marek

    2010-03-01

    Biological research with legitimate scientific purpose that may be misused to pose a biological threat to public health and/or national security is termed dual use. In Poland there are adequate conditions for conducting experiments that could be qualified as dual use research, and therefore, a risk of attack on Poland or other countries exists. Optimal solutions for limiting such threats are required, and the national system of biosecurity should enable early, reliable, and complete identification of this type of research. Scientists should have a fundamental role in this process, their duty being to immediately, upon identification, report research with dual use potential. An important entity in the identification system of dual use research should also be the Central Register of Biological and Biomedical Research, which gathers information about all biological and biomedical research being conducted in a given country. Publishers, editors, and review committees of journals and other scientific publications should be involved in evaluating results of clinical trials. The National Council of Biosecurity should be the governmental institution responsible for developing a system of dual use research threat prevention. Its role would be to develop codes of conduct, form counsel of expertise, and monitor the problem at national level, while the Dual Use Research Committee would be responsible for individual cases. In Poland, current actions aiming to provide biological safety were based on developing and passing an act about genetically modified organisms (GMO's) and creating a GMO Committee. Considering experiences of other nations, one should view these actions as fragmentary, and thus insufficient protection against dual use research threats.

  11. Limited Angle Dual Modality Breast Imaging

    NASA Astrophysics Data System (ADS)

    More, Mitali J.; Li, Heng; Goodale, Patricia J.; Zheng, Yibin; Majewski, Stan; Popov, Vladimir; Welch, Benjamin; Williams, Mark B.

    2007-06-01

    We are developing a dual modality breast scanner that can obtain x-ray transmission and gamma ray emission images in succession at multiple viewing angles with the breast held under mild compression. These views are reconstructed and fused to obtain three-dimensional images that combine structural and functional information. Here, we describe the dual modality system and present results of phantom experiments designed to test the system's ability to obtain fused volumetric dual modality data sets from a limited number of projections, acquired over a limited (less than 180 degrees) angular range. We also present initial results from phantom experiments conducted to optimize the acquisition geometry for gamma imaging. The optimization parameters include the total number of views and the angular range over which these views should be spread, while keeping the total number of detected counts fixed. We have found that in general, for a fixed number of views centered around the direction perpendicular to the direction of compression, in-plane contrast and SNR are improved as the angular range of the views is decreased. The improvement in contrast and SNR with decreasing angular range is much greater for deeper lesions and for a smaller number of views. However, the z-resolution of the lesion is significantly reduced with decreasing angular range. Finally, we present results from limited angle tomography scans using a system with dual, opposing heads.

  12. A Superconducting Dual-Channel Photonic Switch.

    PubMed

    Srivastava, Yogesh Kumar; Manjappa, Manukumara; Cong, Longqing; Krishnamoorthy, Harish N S; Savinov, Vassili; Pitchappa, Prakash; Singh, Ranjan

    2018-06-05

    The mechanism of Cooper pair formation and its underlying physics has long occupied the investigation into high temperature (high-T c ) cuprate superconductors. One of the ways to unravel this is to observe the ultrafast response present in the charge carrier dynamics of a photoexcited specimen. This results in an interesting approach to exploit the dissipation-less dynamic features of superconductors to be utilized for designing high-performance active subwavelength photonic devices with extremely low-loss operation. Here, dual-channel, ultrafast, all-optical switching and modulation between the resistive and the superconducting quantum mechanical phase is experimentally demonstrated. The ultrafast phase switching is demonstrated via modulation of sharp Fano resonance of a high-T c yttrium barium copper oxide (YBCO) superconducting metamaterial device. Upon photoexcitation by femtosecond light pulses, the ultrasensitive cuprate superconductor undergoes dual dissociation-relaxation dynamics, with restoration of superconductivity within a cycle, and thereby establishes the existence of dual switching windows within a timescale of 80 ps. Pathways are explored to engineer the secondary dissociation channel which provides unprecedented control over the switching speed. Most importantly, the results envision new ways to accomplish low-loss, ultrafast, and ultrasensitive dual-channel switching applications that are inaccessible through conventional metallic and dielectric based metamaterials. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Effect of dual-type oligosaccharides on constipation in loperamide-treated rats

    PubMed Central

    Han, Sung Hee; Hong, Ki Bae; Kim, Eun Young; Ahn, So Hyun

    2016-01-01

    BACKGROUND/OBJECTIVES Constipation is a condition that can result from intestinal deformation. Because humans have an upright posture, the effects of gravity can cause this shape deformation. Oligosaccharides are common prebiotics and their effects on bowel health are well known. However, studies of the physiological functionality of a product that contains both lactulose and galactooligosaccharides are insufficient. We investigated the constipation reduction effect of a dual-type oligosaccharide, Dual-Oligo, in loperamide-treated rats. MATERIALS/METHODS Dual-Oligo consists of galactooligosaccharides (15.80%) and lactulose (51.67%). Animals were randomly divided into four groups, the normal group (normal), control group (control), low concentration of Dual-Oligo (LDO) group, and high concentration of Dual-Oligo (HDO) group. After 7 days of oral administration, fecal pellet amount, fecal weight, water content of fecal were measured. Blood chemistry, short-chain fatty acid (SCFA), gastrointestinal transit ratio and length and intestinal mucosa were analyzed. RESULTS Dual-Oligo increased the fecal weight, and water content of feces in rats with loperamide-induced constipation. Gastrointestinal transit ratio and length and area of intestinal mucosa significantly increased after treatment with Dual-Oligo in loperamide-induced rats. A high concentration of Dual-Oligo tended to produce more acetic acid than that observed for the control group, and Dual-Oligo affected the production of total SCFA. Bifidobacteria concentration of cecal contents in the high-concentration oligosaccharide (HDO) and low-concentration oligosaccharide (LDO) groups was similar to the result of the normal group. CONCLUSIONS These results showed that Dual-Oligo is a functional material that is derived from a natural food product and is effective in ameliorating constipation. PMID:27909555

  14. Problems of Dual-Career Black Couples: Identification and Implications for Family Interventions.

    ERIC Educational Resources Information Center

    Thomas, Veronica G.

    1990-01-01

    Examined problems of 41 dual-career Black couples. Findings indicated that dual-career Black couples experienced a number of problems related to their lifestyle. Found unique problems perceived by dual-career Black families. In addition to problems experienced by White dual-career couples, Blacks also faced racial discrimination, social isolation,…

  15. Improved dual-loop detection system for collecting real-time truck data

    DOT National Transportation Integrated Search

    2005-02-01

    The WSDOTs dual-loop detectors capability of measuring vehicle lengths makes the dual-loop detection system a potential real-time truck data source for freight movement study. However, a previous study found the WSDOT dual-loop detection system...

  16. Dual-Fuel Propulsion in Single-Stage Advanced Manned Launch System Vehicle

    NASA Technical Reports Server (NTRS)

    Lepsch, Roger A., Jr.; Stanley, Douglas O.; Unal, Resit

    1995-01-01

    As part of the United States Advanced Manned Launch System study to determine a follow-on, or complement, to the Space Shuttle, a reusable single-stage-to-orbit concept utilizing dual-fuel rocket propulsion has been examined. Several dual-fuel propulsion concepts were investigated. These include: a separate-engine concept combining Russian RD-170 kerosene-fueled engines with space shuttle main engine-derivative engines: the kerosene- and hydrogen-fueled Russian RD-701 engine; and a dual-fuel, dual-expander engine. Analysis to determine vehicle weight and size characteristics was performed using conceptual-level design techniques. A response-surface methodology for multidisciplinary design was utilized to optimize the dual-fuel vehicles with respect to several important propulsion-system and vehicle design parameters, in order to achieve minimum empty weight. The tools and methods employed in the analysis process are also summarized. In comparison with a reference hydrogen- fueled single-stage vehicle, results showed that the dual-fuel vehicles were from 10 to 30% lower in empty weight for the same payload capability, with the dual-expander engine types showing the greatest potential.

  17. Dual Enrollment: The Missing Link to College Readiness

    ERIC Educational Resources Information Center

    Swanson, Joni

    2010-01-01

    Dual enrollment programs have sparked the interest of educational researchers and practitioners who want to determine whether offering college courses to high school students might positively affect their persistence in college or other postsecondary education. Current research suggests that participating in dual enrollment programs improves…

  18. Dual pricing of health sciences periodicals: a survey.

    PubMed Central

    Miller, D R; Jensen, J E

    1980-01-01

    A survey of dual pricing practices among publishers of health-related journals identified 281 periodicals with an average price differential of over 100% between individual and institutional subscription rates. Both the practice itself and the amount of the differential are increasing, indicating that journal subscriptions of health sciences libraries increasingly provide the financial support necessary for the publication of health sciences journals. Dual pricing is also correlated with copyright royalties. The problems that dual pricing creates for health sciences libraries' budgets are due in part to uncritical purchasing by libraries. Increased consumerism on the part of health science librarians is recommended. PMID:7437588

  19. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy.

    PubMed

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-07

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  20. Holographic duals of 3d S-fold CFTs

    NASA Astrophysics Data System (ADS)

    Assel, Benjamin; Tomasiello, Alessandro

    2018-06-01

    We construct non-geometric AdS4 solutions of IIB string theory where the fields in overlapping patches are glued by elements of the S-duality group. We obtain them by suitable quotients of compact and non-compact geometric solutions. The quotient procedure suggests CFT duals as quiver theories with links involving the so-called T [U( N)] theory. We test the validity of the non-geometric solutions (and of our proposed holographic duality) by computing the three-sphere partition function Z of the CFTs. A first class of solutions is obtained by an S-duality quotient of Janus-type non-compact solutions and is dual to 3d N=4 SCFTs; for these we manage to compute Z of the dual CFT at finite N, and it agrees perfectly with the supergravity result in the large N limit. A second class has five-branes, it is obtained by a Möbius-like S-quotient of ordinary compact solutions and is dual to 3d N=3 SCFTs. For these, Z agrees with the supergravity result if one chooses the limit carefully so that the effect of the fivebranes does not backreact on the entire geometry. Other limits suggest the existence of IIA duals.

  1. Single-scan dual-tracer FLT+FDG PET tumor characterization.

    PubMed

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-02-07

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both (18)F-fluorodeoxyglucose (FDG) and (18)F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems--both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), K(net), and K(1) as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k(2), k(3)) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging

  2. Single-scan dual-tracer FLT+FDG PET tumor characterization

    NASA Astrophysics Data System (ADS)

    Kadrmas, Dan J.; Rust, Thomas C.; Hoffman, John M.

    2013-02-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in

  3. Single-scan dual-tracer FLT+FDG PET tumor characterization

    PubMed Central

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-01-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10–60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies

  4. The Wellbeing of Army Personnel in Dual Military Marriages

    DTIC Science & Technology

    2015-11-01

    my pregnant wife, you know, she didn’t have anybody. It was her first kid , our first kid , and nobody paid me to have to watch my son being born over...set and further examined the role that sex has in dual-military marriages, with a focus on career intentions. I predicted that not only is gender...collected thus far: Table 4. Demographic data Married: Dual-Military Married: Not Dual Military N 276 673 Sex Male: 52% Female: 48

  5. Dual-frequency continuous wave optical parametric oscillator

    NASA Astrophysics Data System (ADS)

    Sun, Bingjie; Wang, Xin; Yang, Suhui; Li, Kun

    2018-01-01

    This article shows a dual-frequency OPO with multi-grating (28.5-31.5 μm) periodically poled MgO:LiNbO3 (MgO:PPLN) pumped by a dual-frequency continuous wave at 1.064 μm. The wavelengths of idler and signal varying versus temperature at different periods of inverted domains were numerical simulated. It proves that as the temperature rises, or as the poling period increases, the idler wavelength shortens and signal wavelength lengthens. The pump is a 30 W dual-frequency fiber laser MOPA with beat note frequency varying from 125 MHz to 175 MHz. The pump threshold of the bow-tie ring cavity OPO was 3 W. An average dual-frequency idler output power of 2.6 W was obtained when the pump power was 17.2 W at 45 °C. The idler wavelength was 3.4 μm when the poling period was 30.5 μm. The idler wavelength could be tuned from 2.9 μm to 3.9 μm by changing the temperature and the poling period, and the beat note frequency was proved to be equal to that of the pump.

  6. Dual Enrollment Programs. What Works Clearinghouse Intervention Report

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2017

    2017-01-01

    "Dual enrollment" programs allow high school students to take college courses and earn college credits while still attending high school. Such programs, also referred to as "dual credit" or early college programs, are designed to boost college access and degree attainment, especially for students typically underrepresented in…

  7. Euclidean supersymmetric solutions with the self-dual Weyl tensor

    NASA Astrophysics Data System (ADS)

    Nozawa, Masato

    2017-07-01

    We explore the Euclidean supersymmetric solutions admitting the self-dual gauge field in the framework of N = 2 minimal gauged supergravity in four dimensions. According to the classification scheme utilizing the spinorial geometry or the bilinears of Killing spinors, the general solution preserves one quarter of supersymmetry and is described by the Przanowski-Tod class with the self-dual Weyl tensor. We demonstrate that there exists an additional Killing spinor, provided the Przanowski-Tod metric admits a Killing vector that commutes with the principal one. The proof proceeds by recasting the metric into another Przanowski-Tod form. This formalism enables us to show that the self-dual Reissner-Nordström-Taub-NUT-AdS metric possesses a second Killing spinor, which has been missed over many years. We also address the supersymmetry when the Przanowski-Tod space is conformal to each of the self-dual ambi-toric Kähler metrics. It turns out that three classes of solutions are all reduced to the self-dual Carter family, by virtue of the nondegenerate Killing-Yano tensor.

  8. Adaptive real-time dual-comb spectroscopy.

    PubMed

    Ideguchi, Takuro; Poisson, Antonin; Guelachvili, Guy; Picqué, Nathalie; Hänsch, Theodor W

    2014-02-27

    The spectrum of a laser frequency comb consists of several hundred thousand equally spaced lines over a broad spectral bandwidth. Such frequency combs have revolutionized optical frequency metrology and they now hold much promise for significant advances in a growing number of applications including molecular spectroscopy. Despite an intriguing potential for the measurement of molecular spectra spanning tens of nanometres within tens of microseconds at Doppler-limited resolution, the development of dual-comb spectroscopy is hindered by the demanding stability requirements of the laser combs. Here we overcome this difficulty and experimentally demonstrate a concept of real-time dual-comb spectroscopy, which compensates for laser instabilities by electronic signal processing. It only uses free-running mode-locked lasers without any phase-lock electronics. We record spectra spanning the full bandwidth of near-infrared fibre lasers with Doppler-limited line profiles highly suitable for measurements of concentrations or line intensities. Our new technique of adaptive dual-comb spectroscopy offers a powerful transdisciplinary instrument for analytical sciences.

  9. Adaptive real-time dual-comb spectroscopy

    NASA Astrophysics Data System (ADS)

    Ideguchi, Takuro; Poisson, Antonin; Guelachvili, Guy; Picqué, Nathalie; Hänsch, Theodor W.

    2014-02-01

    The spectrum of a laser frequency comb consists of several hundred thousand equally spaced lines over a broad spectral bandwidth. Such frequency combs have revolutionized optical frequency metrology and they now hold much promise for significant advances in a growing number of applications including molecular spectroscopy. Despite an intriguing potential for the measurement of molecular spectra spanning tens of nanometres within tens of microseconds at Doppler-limited resolution, the development of dual-comb spectroscopy is hindered by the demanding stability requirements of the laser combs. Here we overcome this difficulty and experimentally demonstrate a concept of real-time dual-comb spectroscopy, which compensates for laser instabilities by electronic signal processing. It only uses free-running mode-locked lasers without any phase-lock electronics. We record spectra spanning the full bandwidth of near-infrared fibre lasers with Doppler-limited line profiles highly suitable for measurements of concentrations or line intensities. Our new technique of adaptive dual-comb spectroscopy offers a powerful transdisciplinary instrument for analytical sciences.

  10. Adaptive real-time dual-comb spectroscopy

    PubMed Central

    Ideguchi, Takuro; Poisson, Antonin; Guelachvili, Guy; Picqué, Nathalie; Hänsch, Theodor W.

    2014-01-01

    The spectrum of a laser frequency comb consists of several hundred thousand equally spaced lines over a broad spectral bandwidth. Such frequency combs have revolutionized optical frequency metrology and they now hold much promise for significant advances in a growing number of applications including molecular spectroscopy. Despite an intriguing potential for the measurement of molecular spectra spanning tens of nanometres within tens of microseconds at Doppler-limited resolution, the development of dual-comb spectroscopy is hindered by the demanding stability requirements of the laser combs. Here we overcome this difficulty and experimentally demonstrate a concept of real-time dual-comb spectroscopy, which compensates for laser instabilities by electronic signal processing. It only uses free-running mode-locked lasers without any phase-lock electronics. We record spectra spanning the full bandwidth of near-infrared fibre lasers with Doppler-limited line profiles highly suitable for measurements of concentrations or line intensities. Our new technique of adaptive dual-comb spectroscopy offers a powerful transdisciplinary instrument for analytical sciences. PMID:24572636

  11. Dual antibiotics for bronchiectasis.

    PubMed

    Felix, Lambert M; Grundy, Seamus; Milan, Stephen J; Armstrong, Ross; Harrison, Haley; Lynes, Dave; Spencer, Sally

    2018-06-11

    Bronchiectasis is a chronic respiratory disease characterised by abnormal and irreversible dilatation of the smaller airways and associated with a mortality rate greater than twice that of the general population. Antibiotics serve as front-line therapy for managing bacterial load, but their use is weighed against the development of antibiotic resistance. Dual antibiotic therapy has the potential to suppress infection from multiple strains of bacteria, leading to more successful treatment of exacerbations, reduced symptoms, and improved quality of life. Further evidence is required on the efficacy of dual antibiotics in terms of management of exacerbations and extent of antibiotic resistance. To evaluate the effects of dual antibiotics in the treatment of adults and children with bronchiectasis. We identified studies from the Cochrane Airways Group Specialised Register (CAGR), which includes the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, the Cumulative Index to Nursing and Allied Health Literature (CINAHL), Allied and Complementary Medicine (AMED), and PsycINFO, as well as studies obtained by handsearching of journals/abstracts. We also searched the following trial registries: US National Institutes of Health Ongoing Trials Register, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform. We imposed no restriction on language of publication. We conducted our search in October 2017. We searched for randomised controlled trials comparing dual antibiotics versus a single antibiotic for short-term (< 4 weeks) or long-term management of bronchiectasis diagnosed in adults and/or children by bronchography, plain film chest radiography, or high-resolution computed tomography. Primary outcomes included exacerbations, length of hospitalisation, and serious adverse events. Secondary outcomes were response rates, emergence of resistance to antibiotics, systemic markers of infection, sputum

  12. Dual-energy contrast-enhanced mammography.

    PubMed

    Travieso Aja, M M; Rodríguez Rodríguez, M; Alayón Hernández, S; Vega Benítez, V; Luzardo, O P

    2014-01-01

    The degree of vascularization in breast lesions is related to their malignancy. For this reason, functional diagnostic imaging techniques have become important in recent years. Dual-energy contrast-enhanced mammography is a new, apparently promising technique in breast cancer that provides information about the degree of vascularization of the lesion in addition to the morphological information provided by conventional mammography. This article describes the state of the art for dual-energy contrast-enhanced mammography. Based on 15 months' clinical experience, we illustrate this review with clinical cases that allow us to discuss the advantages and limitations of this technique. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  13. Comparison of dual-biomarker PIB-PET and dual-tracer PET in AD diagnosis.

    PubMed

    Fu, Liping; Liu, Linwen; Zhang, Jinming; Xu, Baixuan; Fan, Yong; Tian, Jiahe

    2014-11-01

    To identify the optimal time window for capturing perfusion information from early (11)C-PIB imaging frames (perfusion PIB, (11)C-pPIB) and to compare the performance of (18)F-FDG PET and "dual biomarker" (11)C-PIB PET [(11)C-pPIB and amyloid PIB ((11)C-aPIB)] for classification of AD, MCI and CN subjects. Forty subjects (14 CN, 12 MCI and 14 AD patients) underwent (18)F-FDG and (11)C-PIB PET studies. Pearson correlation between the (18)F-FDG image and sum of early (11)C-PIB frames was maximised to identify the optimal time window for (11)C-pPIB. The classification power of imaging parameters was evaluated with a leave-one-out validation. A 7-min time window yielded the highest correlation between (18)F-FDG and (11)C-pPIB. (11)C-pPIB and (18)F-FDG images shared a similar radioactive distribution pattern. (18)F-FDG performed better than (11)C-pPIB for the classification of both AD vs. CN and MCI vs. CN. (11)C-pPIB + (11)C-aPIB and (18)F-FDG + (11)C-aPIB yielded the highest classification accuracy for the classification of AD vs. CN, and (18)F-FDG + (11)C-aPIB had the best classification performance for the classification of MCI vs. C-pPIB could serve as a useful biomarker of rCBF for measuring neural activity and improve the diagnostic power of PET for AD in conjunction with (11)C-aPIB. (18)F-FDG and (11)C-PIB dual-tracer PET examination could better detect MCI. • Dual-tracer PET examination provides neurofunctional and neuropathological information for AD diagnosis. • The identified optimal 11C-pPIB time frames had highest correlation with 18F-FDG. • 11C-pPIB images shared a similar radioactive distribution pattern with 18F-FDG images. • 11C-pPIB can provide neurofunctional information. • Dual-tracer PET examination could better detect MCI.

  14. Improved dual-porosity models for petrophysical analysis of vuggy reservoirs

    NASA Astrophysics Data System (ADS)

    Wang, Haitao

    2017-08-01

    A new vug interconnection, isolated vug (IVG), was investigated through resistivity modeling and the dual-porosity model for connected vug (CVG) vuggy reservoirs was tested. The vuggy models were built by pore-scale modeling, and their electrical resistivity was calculated by the finite difference method. For CVG vuggy reservoirs, the CVG reduced formation factors and increased the porosity exponents, and the existing dual-porosity model failed to match these results. Based on the existing dual-porosity model, a conceptual dual-porosity model for CVG was developed by introducing a decoupled term to reduce the resistivity of the model. For IVG vuggy reservoirs, IVG increased the formation factors and porosity exponents. The existing dual-porosity model succeeded due to accurate calculation of the formation factors of the deformed interparticle porous media caused by the insertion of the IVG. Based on the existing dual-porosity model, a new porosity model for IVG vuggy reservoirs was developed by simultaneously recalculating the formation factors of the altered interparticle pore-scale models. The formation factors and porosity exponents from the improved and extended dual-porosity models for CVG and IVG vuggy reservoirs well matched the simulated formation factors and porosity exponents. This work is helpful for understanding the influence of connected and disconnected vugs on resistivity factors—an issue of particular importance in carbonates.

  15. Pueblo Community College, Dual Credit Handbook, 1998-99.

    ERIC Educational Resources Information Center

    Griffith, Mary

    This Dual Credit Handbook from Pueblo Community College (CO) provides information and guidelines to assist instructors in meeting their assignment. These guidelines apply to dual credit courses offered to high school students during their regular school hours, for which students receive high school- and college-level credit simultaneously. This…

  16. A Survey of Dual Career Couples in Engineering.

    ERIC Educational Resources Information Center

    Haemmerlie, Frances M.; Montgomery, Robert L.

    Interest in the problems and concerns of dual career couples has increased markedly in the last decade. However, little research has been done with dual career couples in such traditionally non-female professions as engineering. To examine work, home, personal, and interpersonal characteristics and concerns, married female engineering graduates…

  17. Picometer-resolution dual-comb spectroscopy with a free-running fiber laser.

    PubMed

    Zhao, Xin; Hu, Guoqing; Zhao, Bofeng; Li, Cui; Pan, Yingling; Liu, Ya; Yasui, Takeshi; Zheng, Zheng

    2016-09-19

    Dual-comb spectroscopy holds the promise as real-time, high-resolution spectroscopy tools. However, in its conventional schemes, the stringent requirement on the coherence between two lasers requires sophisticated control systems. By replacing control electronics with an all-optical dual-comb lasing scheme, a simplified dual-comb spectroscopy scheme is demonstrated using one dual-wavelength, passively mode-locked fiber laser. Pulses with a intracavity-dispersion-determined repetition-frequency difference are shown to have good mutual coherence and stability. Capability to resolve the comb teeth and a picometer-wide optical spectral resolution are demonstrated using a simple data acquisition system. Energy-efficient, free-running fiber lasers with a small comb-tooth-spacing could enable low-cost dual-comb systems.

  18. Adverse Effects in Dual-Star Interferometry

    NASA Technical Reports Server (NTRS)

    Colavita, M. Mark

    2008-01-01

    Narrow-angle dual-star interferometric astrometry can provide very high accuracy in the presence of the Earth's turbulent atmosphere. However, to exploit the high atmospherically-limited accuracy requires control of systematic errors in measurement of the interferometer baseline, internal OPDs, and fringe phase. In addition, as high photometric SNR is required, care must be taken to maximize throughput and coherence to obtain high accuracy on faint stars. This article reviews: the keys aspects of the dual-star approach and implementation; the main contributors to the

  19. Gray matter volume and dual-task gait performance in mild cognitive impairment

    PubMed Central

    Blumen, Helena M.; Verghese, Joe; Shimada, Hiroyuki; Makizako, Hyuma; Tsutsumimoto, Kota; Hotta, Ryo; Nakakubo, Sho; Suzuki, Takao

    2017-01-01

    Dual-task gait performance is impaired in older adults with mild cognitive impairment, but the brain substrates associated with dual-task gait performance are not well-established. The relationship between gray matter and gait speed under single-task and dual-task conditions (walking while counting backward) was examined in 560 seniors with mild cognitive impairment (non-amnestic mild cognitive impairment: n = 270; mean age = 72.4 yrs., 63.6 % women; amnestic mild cognitive impairment: n = 290; mean age = 73.4 yrs., 45.4 % women). Multivariate covariance-based analyses of magnetic resonance imaging data, adjusted for potential confounders including single-task gait speed, were performed to identify gray matter patterns associated with dual-task gait speed. There were no differences in gait speed or cognitive performance during dual-task gait between individuals with non-amnestic mild cognitive impairment and amnestic mild cognitive impairment. Overall, increased dual-task gait speed was associated with a gray matter pattern of increased volume in medial frontal gyrus, superior frontal gyrus, anterior cingulate, cingulate, precuneus, fusiform gyrus, middle occipital gyrus, inferior temporal gyrus and middle temporal gyrus. The relationship between dual-task gait speed and brain substrates also differed by mild cognitive impairment subtype. Our study revealed a pattern of gray matter regions associated with dual-task performance. Although dual-task gait performance was similar in amnestic and non-amnestic mild cognitive impairment, the gray matter patterns associated with dual-task gait performance differed by mild cognitive impairment subtype. These findings suggest that the brain substrates supporting dual-task gait performance in amnestic and non-amnestic subtypes are different, and consequently may respond differently to interventions, or require different interventions. PMID:27392792

  20. Comparison of dual and single exposure techniques in dual-energy chest radiography.

    PubMed

    Ho, J T; Kruger, R A; Sorenson, J A

    1989-01-01

    Conventional chest radiography is the most effective tool for lung cancer detection and diagnosis; nevertheless, a high percentage of lung cancer tumors are missed because of the overlap of lung nodule image contrast with bone image contrast in a chest radiograph. Two different energy subtraction strategies, dual exposure and single exposure techniques, were studied for decomposing a radiograph into bone-free and soft tissue-free images to address this problem. For comparing the efficiency of these two techniques in lung nodule detection, the performances of the techniques were evaluated on the basis of residual tissue contrast, energy separation, and signal-to-noise ratio. The evaluation was based on both computer simulation and experimental verification. The dual exposure technique was found to be better than the single exposure technique because of its higher signal-to-noise ratio and greater residual tissue contrast. However, x-ray tube loading and patient motion are problems.

  1. Carcass and meat quality of dual-purpose chickens (Lohmann Dual, Belgian Malines, Schweizerhuhn) in comparison to broiler and layer chicken types.

    PubMed

    Mueller, S; Kreuzer, M; Siegrist, M; Mannale, K; Messikommer, R E; Gangnat, I D M

    2018-05-18

    Currently, there is an intensive ethical discussion about the practice of culling day-old layer cockerels. One solution to avoid this practice could be using dual-purpose types, where males are fattened for meat and females used for egg production. The aim of the present study was to compare fattening performance, carcass conformation, and composition as well as meat quality of Lohmann Dual, a novel dual-purpose type, and 2 traditional dual-purpose types (Belgian Malines and Schweizerhuhn) with 2 broiler types and 1 layer type (Lohmann Brown Plus). Broilers included a conventional line (Ross PM3) and a slower-growing line (Sasso 51) fulfilling requirements of organic farming. Nine birds of each type were fed on a conventional broiler diet. Feed intake and metabolizability of nitrogen and energy were recorded per pen (n = 3), the latter through excreta sampling. For each bird, carcass conformation was assessed, and weights of body, carcass, breast meat, legs, wings, and inner organs were determined. Additionally, breast angle, an indicator for carcass appeal, and skin color were recorded. Meat quality assessment included determinations of thaw and cooking loss, shear force, meat color, and proximate composition of the breast meat. None of the dual-purpose types (20 to 30 g ADG) performed as well in growth as the intensively growing broiler line (68 g ADG). However, Lohmann Dual could compete with the slower-growing broiler line (slower growth but better feed efficiency, similar in carcass weight and breast proportion). Also breast angle was quite similar between Lohmann Dual (100°) and the extensive broiler type (115°C) compared to the intensive broiler line (180°). Meat quality was most favorable in the intensive broilers with the smallest shear force and thawing loss, whereas meat quality was not different between the other types. The Schweizerhuhn performed only at the level of the layer hybrid, and the Belgian Malines was ranked only slightly better.

  2. A new approach for shaping of dual-reflector antennas

    NASA Technical Reports Server (NTRS)

    Lee, Teh-Hong; Burnside, W. D.; Rudduck, Roger C.

    1987-01-01

    The shaping of 2-D dual-reflector antenna systems to generate a prescribed distribution with uniform phase at the aperture of the second reflector is examined. This method is based on the geometrical nature of Cassegrain and Gregorian dual-reflector antennas. The method of syntheses satisfies the principles of geometrical optics which are the foundations of dual-reflector designs. Instead of setting up differential equations or heuristically designing the subreflector, a set of algebraic equations is formulated and solved numerically to obtain the desired surfaces. The caustics of the reflected rays from the subreflector can be obtained and examined. Several examples of 2-D dual-reflector shaping are shown to validate the study. Geometrical optics and physical optics are used to calculate the scattered fields from the reflectors.

  3. Dual-band polarization-/angle-insensitive metamaterial absorber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiong, Han; Chongqing University, College of Communication Engineering, Chongqing, 400044; Zhong, Lin-Lin

    A dual-band metamaterial absorber (MA) based on triangular resonators is designed and investigated in this paper. It is composed of a two-dimensional periodic metal-dielectric-metal sandwiches array on a dielectric substrate. The simulation results clearly show that this absorber has two absorption peaks at 14.9 and 18.9 GHz, respectively, and experiments are conducted to verify the proposed designs effectively. For each polarization, the dual-band absorber is insensitive to the incident angle (up to 60°) and the absorption peaks remain high for both transverse electric (TE) and transverse magnetic (TM) radiation. To study the physical mechanism of power loss, the current distributionmore » at the dual absorption peaks is given. The MA proposed in this paper has potential applications in many scientific and martial fields.« less

  4. In vivo Study of the Accuracy of Dual-arch Impressions.

    PubMed

    de Lima, Luciana Martinelli Santayana; Borges, Gilberto Antonio; Junior, Luiz Henrique Burnett; Spohr, Ana Maria

    2014-06-01

    This study evaluated in vivo the accuracy of metal (Smart®) and plastic (Triple Tray®) dual-arch trays used with vinyl polysiloxane (Flexitime®), in the putty/wash viscosity, as well as polyether (Impregum Soft®) in the regular viscosity. In one patient, an implant-level transfer was screwed on an implant in the mandibular right first molar, serving as a pattern. Ten impressions were made with each tray and impression material. The impressions were poured with Type IV gypsum. The width and height of the pattern and casts were measured in a profile projector (Nikon). The results were submitted to Student's t-test for one sample (α = 0.05). For the width distance, the plastic dual-arch trays with vinyl polysiloxane (4.513 mm) and with polyether (4.531 mm) were statistically wider than the pattern (4.489 mm). The metal dual-arch tray with vinyl polysiloxane (4.504 mm) and with polyether (4.500 mm) did not differ statistically from the pattern. For the height distance, only the metal dual-arch tray with polyether (2.253 mm) differed statistically from the pattern (2.310 mm). The metal dual-arch tray with vinyl polysiloxane, in the putty/wash viscosities, reproduced casts with less distortion in comparison with the same technique with the plastic dual-arch tray. The plastic or metal dual-arch trays with polyether reproduced cast with greater distortion. How to cite the article: Santayana de Lima LM, Borges GA, Burnett LH Jr, Spohr AM. In vivo study of the accuracy of dual-arch impressions. J Int Oral Health 2014;6(3):50-5.

  5. Titanium nitride formation by a dual-stage femtosecond laser process

    NASA Astrophysics Data System (ADS)

    Hammouti, S.; Holybee, B.; Zhu, W.; Allain, J. P.; Jurczyk, B.; Ruzic, D. N.

    2018-06-01

    Formation of TiN by femtosecond laser processing in controlled gas atmosphere is reported. A dual-stage process was designed and aimed to first remove and restructure the native oxide layer of titanium surface through laser irradiation under an argon-controlled atmosphere, and then to maximize titanium nitride formation through an irradiation under a nitrogen reactive environment. An extensive XPS study was performed to identify and quantify laser-induced titanium surface chemistry modifications after a single-stage laser process (Ar and N2 individually), and a dual-stage laser process. The importance of each step that composes the dual-stage laser process was demonstrated and leads to the dual-stage laser process for the formation of TiO, Ti2O3 and TiN. In this study, the largest nitride formation occurs for the dual stage process with laser conditions at 4 W/1.3 J cm-2 under argon and 5 W/1.6 J cm-2 under nitrogen, yielding a total TiN composition of 8.9%. Characterization of both single-stage and dual-stage laser process-induced surface morphologies has been performed as well, leading to the observation of a wide range of hierarchical surface structures such as high-frequency ripples, grooves, protuberances and pillow-like patterns. Finally, water wettability was assessed by means of contact angle measurements on untreated titanium surface, and titanium surfaces resulting from either single-stage laser process or dual-stage laser process. Dual-stage laser process allows a transition of titanium surface, from phobic (93°) to philic (35°), making accessible both hydrophilic and chemically functionalized hierarchical surfaces.

  6. Dual delivery of biological therapeutics for multimodal and synergistic cancer therapies.

    PubMed

    Jang, Bora; Kwon, Hyokyoung; Katila, Pramila; Lee, Seung Jin; Lee, Hyukjin

    2016-03-01

    Cancer causes >8.2 million deaths annually worldwide; thus, various cancer treatments have been investigated over the past decades. Among them, combination drug therapy has become extremely popular, and treatment with more than one drug is often necessary to achieve appropriate anticancer efficacy. With the development of nanoformulations and nanoparticulate-based drug delivery, researchers have explored the feasibility of dual delivery of biological therapeutics to overcome the current drawbacks of cancer therapy. Compared with the conventional single drug therapy, dual delivery of therapeutics has provided various synergistic effects in addition to offering multimodality to cancer treatment. In this review, we highlight and summarize three aspects of dual-delivery systems for cancer therapy. These include (1) overcoming drug resistance by the dual delivery of chemical drugs with biological therapeutics for synergistic therapy, (2) targeted and controlled drug release by the dual delivery of drugs with stimuli-responsive nanomaterials, and (3) multimodal theranostics by the dual delivery of drugs and molecular imaging probes. Furthermore, recent developments, perspectives, and new challenges regarding dual-delivery systems for cancer therapy are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Attentional Control via Parallel Target-Templates in Dual-Target Search

    PubMed Central

    Barrett, Doug J. K.; Zobay, Oliver

    2014-01-01

    Simultaneous search for two targets has been shown to be slower and less accurate than independent searches for the same two targets. Recent research suggests this ‘dual-target cost’ may be attributable to a limit in the number of target-templates than can guide search at any one time. The current study investigated this possibility by comparing behavioural responses during single- and dual-target searches for targets defined by their orientation. The results revealed an increase in reaction times for dual- compared to single-target searches that was largely independent of the number of items in the display. Response accuracy also decreased on dual- compared to single-target searches: dual-target accuracy was higher than predicted by a model restricting search guidance to a single target-template and lower than predicted by a model simulating two independent single-target searches. These results are consistent with a parallel model of dual-target search in which attentional control is exerted by more than one target-template at a time. The requirement to maintain two target-templates simultaneously, however, appears to impose a reduction in the specificity of the memory representation that guides search for each target. PMID:24489793

  8. Dual-band plasmonic resonator based on Jerusalem cross-shaped nanoapertures

    NASA Astrophysics Data System (ADS)

    Cetin, Arif E.; Kaya, Sabri; Mertiri, Alket; Aslan, Ekin; Erramilli, Shyamsunder; Altug, Hatice; Turkmen, Mustafa

    2015-06-01

    In this paper, we both experimentally and numerically introduce a dual-resonant metamaterial based on subwavelength Jerusalem cross-shaped apertures. We numerically investigate the physical origin of the dual-resonant behavior, originating from the constituting aperture elements, through finite difference time domain calculations. Our numerical calculations show that at the dual-resonances, the aperture system supports large and easily accessible local electromagnetic fields. In order to experimentally realize the aperture system, we utilize a high-precision and lift-off free fabrication method based on electron-beam lithography. We also introduce a fine-tuning mechanism for controlling the dual-resonant spectral response through geometrical device parameters. Finally, we show the aperture system's highly advantageous far- and near-field characteristics through numerical calculations on refractive index sensitivity. The quantitative analyses on the availability of the local fields supported by the aperture system are employed to explain the grounds behind the sensitivity of each spectral feature within the dual-resonant behavior. Possessing dual-resonances with large and accessible electromagnetic fields, Jerusalem cross-shaped apertures can be highly advantageous for wide range of applications demanding multiple spectral features with strong nearfield characteristics.

  9. Self-dual Skyrmions on the spheres S2 N +1

    NASA Astrophysics Data System (ADS)

    Amari, Y.; Ferreira, L. A.

    2018-04-01

    We construct self-dual sectors for scalar field theories on a (2 N +2 )-dimensional Minkowski space-time with the target space being the 2 N +1 -dimensional sphere S2 N +1. The construction of such self-dual sectors is made possible by the introduction of an extra functional in the action that renders the static energy and the self-duality equations conformally invariant on the (2 N +1 )-dimensional spatial submanifold. The conformal and target-space symmetries are used to build an ansatz that leads to an infinite number of exact self-dual solutions with arbitrary values of the topological charge. The five-dimensional case is discussed in detail, where it is shown that two types of theories admit self-dual sectors. Our work generalizes the known results in the three-dimensional case that lead to an infinite set of self-dual Skyrmion solutions.

  10. Dual-Energy Computed Tomography in Cardiothoracic Vascular Imaging.

    PubMed

    De Santis, Domenico; Eid, Marwen; De Cecco, Carlo N; Jacobs, Brian E; Albrecht, Moritz H; Varga-Szemes, Akos; Tesche, Christian; Caruso, Damiano; Laghi, Andrea; Schoepf, Uwe Joseph

    2018-07-01

    Dual energy computed tomography is becoming increasingly widespread in clinical practice. It can expand on the traditional density-based data achievable with single energy computed tomography by adding novel applications to help reach a more accurate diagnosis. The implementation of this technology in cardiothoracic vascular imaging allows for improved image contrast, metal artifact reduction, generation of virtual unenhanced images, virtual calcium subtraction techniques, cardiac and pulmonary perfusion evaluation, and plaque characterization. The improved diagnostic performance afforded by dual energy computed tomography is not associated with an increased radiation dose. This review provides an overview of dual energy computed tomography cardiothoracic vascular applications. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Dual redundant arm system operational quality measures and their applications - Static measures

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan; Kim, Sungbok

    1990-01-01

    The authors present dual-arm system static operational quality measures which quantify the efficiency and capability of a dual-arm system in generating Cartesian velocities and static forces. First, they define and analyze the kinematic interactions between the two arms incurred by the various modes of dual-arm cooperation, such as transport, assembly, and grasping modes of cooperation, and specify the kinematic constraints imposed on individual arms in Cartesian space due to the kinematic interactions. Dual-arm static manipulability is presented. Finally, dual-arm operational quality is scaled by a task-oriented operational quality measure (TOQs) obtained by the comparison between the desired and actual static manipulabilities. TOQs is used in the optimization of dual-arm joint configurations. Simulation results are shown.

  12. Testing the Limits of Optimizing Dual-Task Performance in Younger and Older Adults

    PubMed Central

    Strobach, Tilo; Frensch, Peter; Müller, Herrmann Josef; Schubert, Torsten

    2012-01-01

    Impaired dual-task performance in younger and older adults can be improved with practice. Optimal conditions even allow for a (near) elimination of this impairment in younger adults. However, it is unknown whether such (near) elimination is the limit of performance improvements in older adults. The present study tests this limit in older adults under conditions of (a) a high amount of dual-task training and (b) training with simplified component tasks in dual-task situations. The data showed that a high amount of dual-task training in older adults provided no evidence for an improvement of dual-task performance to the optimal dual-task performance level achieved by younger adults. However, training with simplified component tasks in dual-task situations exclusively in older adults provided a similar level of optimal dual-task performance in both age groups. Therefore through applying a testing the limits approach, we demonstrated that older adults improved dual-task performance to the same level as younger adults at the end of training under very specific conditions. PMID:22408613

  13. Dual band metamaterial perfect absorber based on artificial dielectric "molecules".

    PubMed

    Liu, Xiaoming; Lan, Chuwen; Li, Bo; Zhao, Qian; Zhou, Ji

    2016-07-13

    Dual band metamaterial perfect absorbers with two absorption bands are highly desirable because of their potential application areas such as detectors, transceiver system, and spectroscopic imagers. However, most of these dual band metamaterial absorbers proposed were based on resonances of metal patterns. Here, we numerically and experimentally demonstrate a dual band metamaterial perfect absorber composed of artificial dielectric "molecules" with high symmetry. The artificial dielectric "molecule" consists of four "atoms" of two different sizes corresponding to two absorption bands with near unity absorptivity. Numerical and experimental absorptivity verify that the dual-band metamaterial absorber is polarization insensitive and can operate in wide-angle incidence.

  14. Dual-fuel natural gas/diesel engines: Technology, performance, and emissions

    NASA Astrophysics Data System (ADS)

    Turner, S. H.; Weaver, C. S.

    1994-11-01

    An investigation of current dual-fuel natural gas/diesel engine design, performance, and emissions was conducted. The most pressing technological problems associated with dual-fuel engine use were identified along with potential solutions. It was concluded that dual-fuel engines can achieve low NO(sub x) and particulate emissions while retaining fuel-efficiency and BMEP levels comparable to those of diesel engines. The investigation also examined the potential economic impact of dual-fuel engines in diesel-electric locomotives, marine vessels, farm equipment, construction, mining, and industrial equipment, and stand-alone electricity generation systems. Recommendations for further additional funding to support research, development, and demonstration in these applications were then presented.

  15. Power-efficient dual-rate optical transceiver.

    PubMed

    Zuo, Yongrong; Kiamiley, Fouad E; Wang, Xiaoqing; Gui, Ping; Ekman, Jeremy; Wang, Xingle; McFadden, Michael J; Haney, Michael W

    2005-11-20

    A dual-rate (2 Gbit/s and 100 Mbit/s) optical transceiver designed for power-efficient connections within and between modern high-speed digital systems is described. The transceiver can dynamically adjust its data rate according to performance requirements, allowing for power-on-demand operation. Dynamic power management permits energy saving and lowers device operating temperatures, improving the reliability and lifetime of optoelectronic-devices such as vertical-cavity surface-emitting lasers (VCSELs). To implement dual-rate functionality, we include in the transmitter and receiver circuits separate high-speed and low-power data path modules. The high-speed module is designed for gigabit operation to achieve high bandwidth. A simpler low-power module is designed for megabit data transmission with low power consumption. The transceiver is fabricated in a 0.5 microm silicon-on-sapphire complementary metal-oxide semiconductor. The VCSEL and photodetector devices are attached to the transceiver's integrated circuit by flip-chip bonding. A free-space optical link system is constructed to demonstrate correct dual-rate functionality. Experimental results show reliable link operation at 2 Gbit/s and 100 Mbit/s data transfer rates with approximately 104 and approximately 9 mW power consumption, respectively. The transceiver's switching time between these two data rates is demonstrated as 10 micros, which is limited by on-chip register reconfiguration time. Improvement of this switching time can be obtained by use of dedicated input-output pads for dual-rate control signals.

  16. [Dual Pathology in General Population of Itagüí, Colombia].

    PubMed

    Castaño Pérez, Guillermo A; Sierra Hincapié, Gloria Maria

    2016-01-01

    To study the prevalence of dual diagnosis (presence of a substance use disorder and an associated mental disorder) in the general population of a small town in the department of Antioquia in Colombia, through secondary analysis of survey data on Mental Health held in this city in 2011. With a sample of 415 subjects, the interview Composite International Diagnostic Interview (CIDI), WHO CAPI version, was used and statistical analysis was performed using SPSS v.21. The prevalence of dual diagnosis, considering that the presence of a diagnosis of mental disorder and a disorder snuff use of different substances was 7.2%. Substances with higher prevalence of use in life for individuals with dual diagnosis were alcohol (96.7%), marijuana (80.0%), cocaine and derivatives (33.3%), heroin (23.3%) and finally no prescription tranquilizers (13.3%), finding statistical association between drug use and dual diagnosis. Major depression (40%), oppositional defiant disorder (36.7%), posttraumatic stress (33.3%), specific phobia and attention deficit (26.7%) are the most prevalent disorders in individuals with dual diagnosis of this sample. Alcohol or drugs consumption and fulfilling diagnostic criteria for dual diagnosis have a significant statistical association for consumption of drugs like marijuana, cocaine, heroin and prescription medications (P<0.001), all with disparity ratios of >1.00, very high when the drug is heroin consumed (RD=38.754) or non-prescription medications (RD=29.462). A family history of disease and drug use has a high statistical association with dual diagnosis, with a higher association with a history of mental illness (P<.001; RD=3.677). The study reports on the prevalence of subjects with dual diagnosis in a Colombian population. Alcohol, marijuana, cocaine and heroin are derivatives and substances mostly consumed by these patients and the most prevalent mental disorders are depression, TOD and posttraumatic stress. These findings motivate clinicians to

  17. Comparison study of noise reduction algorithms in dual energy chest digital tomosynthesis

    NASA Astrophysics Data System (ADS)

    Lee, D.; Kim, Y.-S.; Choi, S.; Lee, H.; Choi, S.; Kim, H.-J.

    2018-04-01

    Dual energy chest digital tomosynthesis (CDT) is a recently developed medical technique that takes advantage of both tomosynthesis and dual energy X-ray images. However, quantum noise, which occurs in dual energy X-ray images, strongly interferes with diagnosis in various clinical situations. Therefore, noise reduction is necessary in dual energy CDT. In this study, noise-compensating algorithms, including a simple smoothing of high-energy images (SSH) and anti-correlated noise reduction (ACNR), were evaluated in a CDT system. We used a newly developed prototype CDT system and anthropomorphic chest phantom for experimental studies. The resulting images demonstrated that dual energy CDT can selectively image anatomical structures, such as bone and soft tissue. Among the resulting images, those acquired with ACNR showed the best image quality. Both coefficient of variation and contrast to noise ratio (CNR) were the highest in ACNR among the three different dual energy techniques, and the CNR of bone was significantly improved compared to the reconstructed images acquired at a single energy. This study demonstrated the clinical value of dual energy CDT and quantitatively showed that ACNR is the most suitable among the three developed dual energy techniques, including standard log subtraction, SSH, and ACNR.

  18. Transferability of Dual-Task Coordination Skills after Practice with Changing Component Tasks

    PubMed Central

    Schubert, Torsten; Liepelt, Roman; Kübler, Sebastian; Strobach, Tilo

    2017-01-01

    Recent research has demonstrated that dual-task performance with two simultaneously presented tasks can be substantially improved as a result of practice. Among other mechanisms, theories of dual-task practice-relate this improvement to the acquisition of task coordination skills. These skills are assumed (1) to result from dual-task practice, but not from single-task practice, and (2) to be independent from the specific stimulus and response mappings during the practice situation and, therefore, transferable to new dual task situations. The present study is the first that provides an elaborated test of these assumptions in a context with well-controllable practice and transfer situations. To this end, we compared the effects of dual-task and single-task practice with a visual and an auditory sensory-motor component task on the dual-task performance in a subsequent transfer session. Importantly, stimulus and stimulus-response mapping conditions in the two component tasks changed repeatedly during practice sessions, which prevents that automatized stimulus-response associations may be transferred from practice to transfer. Dual-task performance was found to be improved after practice with the dual tasks in contrast to the single-task practice. These findings are consistent with the assumption that coordination skills had been acquired, which can be transferred to other dual-task situations independently on the specific stimulus and response mapping conditions of the practiced component tasks. PMID:28659844

  19. Dual-Use system architecture for a space situational awareness system in Japan

    NASA Astrophysics Data System (ADS)

    Otani, Y.; Kohtake, N.; Ohkami, Y.

    The use of outer space plays a vital role in both defense and civil fields. Since the separation of space activities between civil and defense applications is extremely inefficient, the Dual-Use concept has been considered fundamental for promoting the effective use of space. To the best of the authors' knowledge, most previous studies on Dual-Use focused on the technological aspects, and very few on a system engineering approach to Dual-Use. This left some important issues untouched such as the operational aspects of a system of systems, which need to be understood in a more generic context. This paper presents the results of a conceptual study, system design and management analysis of Dual-Use system architecture. First, an outline of the Dual-Use concept will be described and a definition of Dual-Use given. The effectiveness of applying the Dual-Use system concept to Space Situational Awareness (SSA) for both defense and civil users as a system of systems will then be discussed and investigated with a stakeholders analysis, context diagram and design structure matrix method. It has demonstrated that there is a need for a Dual-Use SSA Data Center which works as a binder between defense and civil systems as well as a data policy for constructing a Dual-Use SSA system.

  20. Possibilities, intentions and threats: dual use in the life sciences reconsidered.

    PubMed

    van der Bruggen, Koos

    2012-12-01

    Due to the terrorist attacks of 9/11 and the anthrax letters of a few weeks later, the concept of dual use has spread widely in the life sciences during the past decade. This article is aimed at a clarification of the dual use concept and its scope of application for the life sciences. Such a clarification would greatly facilitate the work of policymakers seeking to ensure security while avoiding undesirable interventions of government in the conduct of science. The article starts with an overview of the main developments in life sciences in relation to dual use. This is illustrated by discussions on synthetic biology and dual use. The findings lead to a reconsideration of the dual use concept. An area in need of further attention is to what extent threats and intentions should have impact on the definition of dual use. Possible threats are analyzed against the background of the phenomenon of securitization of health care and life sciences: considering these sectors of society in security terms. Some caveats that should be taken into account in a dual use policy are described. An acceptable, adequate and applicable definition of the dual use concept could help researchers, universities, companies and policy makers. Such a definition should build upon, but go beyond, the view developed in the influential Fink-report, which concentrates on the so-called 'experiments of concern', e.g. experiments that enhance the virulence of pathogens (National Research Council of the National Academies 2004) It will be argued that-in addition to these more technical aspects-a definition of dual use should include the aspect of threats and intentions.

  1. Increased integrity of white matter pathways after dual n-back training.

    PubMed

    Salminen, Tiina; Mårtensson, Johan; Schubert, Torsten; Kühn, Simone

    2016-06-01

    Dual n-back WM training has been shown to produce broad transfer effects to different untrained cognitive functions. The task is demanding to the cognitive system because it includes a bi-modal (auditory and visual) dual-task component. A previous WM training study showed increased white matter integrity in the parietal lobe as well as the anterior part of the corpus callosum after visual n-back training. We investigated dual n-back training-related changes in white matter pathways. We anticipated dual n-back training to increase white matter integrity in pathways that connect brain regions related to WM processes. Additionally, we hypothesized that dual n-back training would produce more brain-wide white matter changes than single n-back training because of the involvement of two modalities and the additional dual-task coordination component of the task. The dual n-back training group showed increased white matter integrity (reflected as increased fractional anisotropy, FA) after training. The effects were mostly left lateralized as compared with changes from pretest to posttest in the passive and active control groups. Additionally, significant effects were observed in the anterior part of the corpus callosum, when the training group was compared with the passive control group. There were no changes in pretest to posttest FA changes between the passive and active control groups. The results therefore show that dual n-back training produces increased integrity in white matter pathways connecting different brain regions. The results are discussed in reference to the bi-modal dual-task component of the training task. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Determinants of Marital Quality in Dual Career Couples.

    ERIC Educational Resources Information Center

    Thomas, Sandra; And Others

    Dual career families were exceptions to the norm in the 1960's but have steadily increased in prevalence. Dual career professional couples (N=34) were studied to assess the determinants of marital quality and stability in their relationships. Results revealed that couples in high quality marriages reported satisfaction with all aspects of…

  3. Gray matter volume and dual-task gait performance in mild cognitive impairment.

    PubMed

    Doi, Takehiko; Blumen, Helena M; Verghese, Joe; Shimada, Hiroyuki; Makizako, Hyuma; Tsutsumimoto, Kota; Hotta, Ryo; Nakakubo, Sho; Suzuki, Takao

    2017-06-01

    Dual-task gait performance is impaired in older adults with mild cognitive impairment, but the brain substrates associated with dual-task gait performance are not well-established. The relationship between gray matter and gait speed under single-task and dual-task conditions (walking while counting backward) was examined in 560 seniors with mild cognitive impairment (non-amnestic mild cognitive impairment: n = 270; mean age = 72.4 yrs., 63.6 % women; amnestic mild cognitive impairment: n = 290; mean age = 73.4 yrs., 45.4 % women). Multivariate covariance-based analyses of magnetic resonance imaging data, adjusted for potential confounders including single-task gait speed, were performed to identify gray matter patterns associated with dual-task gait speed. There were no differences in gait speed or cognitive performance during dual-task gait between individuals with non-amnestic mild cognitive impairment and amnestic mild cognitive impairment. Overall, increased dual-task gait speed was associated with a gray matter pattern of increased volume in medial frontal gyrus, superior frontal gyrus, anterior cingulate, cingulate, precuneus, fusiform gyrus, middle occipital gyrus, inferior temporal gyrus and middle temporal gyrus. The relationship between dual-task gait speed and brain substrates also differed by mild cognitive impairment subtype. Our study revealed a pattern of gray matter regions associated with dual-task performance. Although dual-task gait performance was similar in amnestic and non-amnestic mild cognitive impairment, the gray matter patterns associated with dual-task gait performance differed by mild cognitive impairment subtype. These findings suggest that the brain substrates supporting dual-task gait performance in amnestic and non-amnestic subtypes are different, and consequently may respond differently to interventions, or require different interventions.

  4. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PRDual chamber detection algorithms evaluated in a subset of diagnostically difficult arrhythmias allow safe detection of double tachycardias but require further extension and programmability to

  5. Dual-Modality, Dual-Functional Nanoprobes for Cellular and Molecular Imaging

    PubMed Central

    Menon, Jyothi U.; Gulaka, Praveen K.; McKay, Madalyn A.; Geethanath, Sairam; Liu, Li; Kodibagkar, Vikram D.

    2012-01-01

    An emerging need for evaluation of promising cellular therapies is a non-invasive method to image the movement and health of cells following transplantation. However, the use of a single modality to serve this purpose may not be advantageous as it may convey inaccurate or insufficient information. Multi-modal imaging strategies are becoming more popular for in vivo cellular and molecular imaging because of their improved sensitivity, higher resolution and structural/functional visualization. This study aims at formulating Nile Red doped hexamethyldisiloxane (HMDSO) nanoemulsions as dual modality (Magnetic Resonance Imaging/Fluorescence), dual-functional (oximetry/detection) nanoprobes for cellular and molecular imaging. HMDSO nanoprobes were prepared using a HS15-lecithin combination as surfactant and showed an average radius of 71±39 nm by dynamic light scattering and in vitro particle stability in human plasma over 24 hrs. They were found to readily localize in the cytosol of MCF7-GFP cells within 18 minutes of incubation. As proof of principle, these nanoprobes were successfully used for fluorescence imaging and for measuring pO2 changes in cells by magnetic resonance imaging, in vitro, thus showing potential for in vivo applications. PMID:23382776

  6. Dual Use of Smokeless Tobacco or E-cigarettes with Cigarettes and Cessation

    PubMed Central

    Kalkhoran, Sara; Grana, Rachel A.; Neilands, Torsten B.; Ling, Pamela M.

    2015-01-01

    Objectives To evaluate predictors of dual use of cigarettes with smokeless tobacco or e-cigarettes. Methods Adult smokers (N = 1324) completed online cross-sectional surveys. Logistic regression evaluated predictors of dual use and cigarette quit attempts. Results Smokeless tobacco dual use was associated with past attempts to quit smoking by switching to smokeless products. E-cigarette dual use was associated with using stop-smoking medication and strong anti-tobacco industry attitudes. Ever use of stop-smoking medication was associated with quit attempts among dual e-cigarette users and cigarette-only users. Conclusions Dual users are more likely than cigarette-only users to endorse certain cessation-related attitudes and behaviors. This may provide an opportunity for clinicians or others to discuss evidence-based strategies for smoking cessation. PMID:25564840

  7. Thermodynamic Analysis of Dual-Mode Scramjet Engine Operation and Performance

    NASA Technical Reports Server (NTRS)

    Riggins, David; Tacket, Regan; Taylor, Trent; Auslender, Aaron

    2006-01-01

    Recent analytical advances in understanding the performance continuum (the thermodynamic spectrum) for air-breathing engines based on fundamental second-law considerations have clarified scramjet and ramjet operation, performance, and characteristics. Second-law based analysis is extended specifically in this work to clarify and describe the performance characteristics for dual-mode scramjet operation in the mid-speed range of flight Mach 4 to 7. This is done by a fundamental investigation of the complex but predictable interplay between heat release and irreversibilities in such an engine; results demonstrate the flow and performance character of the dual mode regime and of dual mode transition behavior. Both analytical and computational (multi-dimensional CFD) studies of sample dual-mode flow-fields are performed in order to demonstrate the second-law capability and performance and operability issues. The impact of the dual-mode regime is found to be characterized by decreasing overall irreversibility with increasing heat release, within the operability limits of the system.

  8. Closed head injury and perceptual processing in dual-task situations.

    PubMed

    Hein, G; Schubert, T; von Cramon, D Y

    2005-01-01

    Using a classical psychological refractory period (PRP) paradigm we investigated whether increased interference between dual-task input processes is one possible source of dual-task deficits in patients with closed-head injury (CHI). Patients and age-matched controls were asked to give speeded motor reactions to an auditory and a visual stimulus. The perceptual difficulty of the visual stimulus was manipulated by varying its intensity. The results of Experiment 1 showed that CHI patients suffer from increased interference between dual-task input processes, which is related to the salience of the visual stimulus. A second experiment indicated that this input interference may be specific to brain damage following CHI. It is not evident in other groups of neurological patients like Parkinson's disease patients. We conclude that the non-interfering processing of input stages in dual-tasks requires cognitive control. A decline in the control of input processes should be considered as one source of dual-task deficits in CHI patients.

  9. Technology, Applications, and Process Challenges of Dual Chamber Systems.

    PubMed

    Werk, Tobias; Ludwig, Imke S; Luemkemann, Joerg; Mahler, Hanns-Christian; Huwyler, Joerg; Hafner, Mathias

    2016-01-01

    Dual-chamber systems provide an option as a drug and device combination product, when home care and emergency lyophilized products are intended. Nevertheless, until today, there are only a few products on the market, due to the challenges and limitations in manufacturability, product formulation, and product stability in a dual-chamber configuration, as well as economic considerations. This review serves to describe currently available dual-chamber systems and to discuss factors to be considered for appropriate selection and establishing fill-finish processes. Copyright © 2016. Published by Elsevier Inc.

  10. Dual-opioid therapy: changing the paradigm. Introduction.

    PubMed

    Nicholson, Bruce D

    2012-03-01

    Morphine sulfate and oxycodone hydrochloride are commonly used for pain management because of their pharmacologic profile, pharmacokinetics, and analgesic potency. However, opioids are associated with a significant adverse event (AE) burden that limits their use in both the acute and the chronic pain settings. Co-administration of opioids demonstrated synergistic analgesia and reduced side effects. Thus, dual-opioid therapy has the potential to enhance the positive analgesic benefits of opioids, while limiting the burden of opioid-related AEs. This symposium proceedings was based on presentations at the 13th World Congress on Pain in August 2010. This program will review the rationale for dual-opioid therapy based on preclinical findings and data from clinical studies showing the efficacy and tolerability profile of a dual-opioid formulation when used to treat acute postoperative pain. Wiley Periodicals, Inc.

  11. Dual Credit, College Type, and Enhanced Degree Attainment

    ERIC Educational Resources Information Center

    Blankenberger, Bob; Lichtenberger, Eric; Witt, M. Allison

    2017-01-01

    In this study, we analyzed data for the Illinois high school class of 2003 to determine the impact of dual credit participation on postsecondary attainment. We matched 8,095 dual credit participants to an equal number of nonparticipants within the same high school at the point of postsecondary enrollment using propensity scores calculated through…

  12. 26 CFR 1.1503-2 - Dual consolidated loss.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 12 2011-04-01 2011-04-01 false Dual consolidated loss. 1.1503-2 Section 1.1503-2 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Administrative Provisions and Other Rules § 1.1503-2 Dual consolidated loss. (a) Purpose and scope. This section...

  13. Using dual-purpose crops in sheep-grazing systems.

    PubMed

    Dove, Hugh; Kirkegaard, John

    2014-05-01

    The utilisation of dual-purpose crops, especially wheat and canola grown for forage and grain production in sheep-grazing systems, is reviewed. When sown early and grazed in winter before stem elongation, later-maturing wheat and canola crops can be grazed with little impact on grain yield. Recent research has sought to develop crop- and grazing-management strategies for dual-purpose crops. Aspects examined have been grazing effects on crop growth, recovery and yield development along with an understanding of the grazing value of the crop fodder, its implications for animal nutrition and grazing management to maximise live-weight gain. By alleviating the winter 'feed gap', the increase in winter stocking rate afforded by grazing crops allows crop and livestock production to be increased simultaneously on the same farm. Integration of dual-purpose wheat with canola on mixed farms provides further systems advantages related to widened operational windows, weed and disease control and risk management. Dual-purpose crops are an innovation that has potential to assist in addressing the global food-security challenge. © 2013 Society of Chemical Industry.

  14. Bistability in dual-frequency nematic liquid crystals

    NASA Astrophysics Data System (ADS)

    Palto, S. P.; Barnik, M. I.

    2007-03-01

    Different modes of bistable switching in liquid crystals with frequency inversion of the dielectric anisotropy sign are discussed. The study is performed by numerical simulation and experimentally. It is shown that dual frequency driving can be effectively used to control switching between topologically equivalent and non-equivalent director field distributions. The experimental results on temperature performance of the dual-frequency switching and possible driving methods for energy consumption and expanding the temperature range are presented.

  15. Spatiotemporal Targeting of a Dual-Ligand Nanoparticle to Cancer Metastasis.

    PubMed

    Doolittle, Elizabeth; Peiris, Pubudu M; Doron, Gilad; Goldberg, Amy; Tucci, Samantha; Rao, Swetha; Shah, Shruti; Sylvestre, Meilyn; Govender, Priya; Turan, Oguz; Lee, Zhenghong; Schiemann, William P; Karathanasis, Efstathios

    2015-08-25

    Various targeting strategies and ligands have been employed to direct nanoparticles to tumors that upregulate specific cell-surface molecules. However, tumors display a dynamic, heterogeneous microenvironment, which undergoes spatiotemporal changes including the expression of targetable cell-surface biomarkers. Here, we investigated a dual-ligand nanoparticle to effectively target two receptors overexpressed in aggressive tumors. By using two different chemical specificities, the dual-ligand strategy considered the spatiotemporal alterations in the expression patterns of the receptors in cancer sites. As a case study, we used two mouse models of metastasis of triple-negative breast cancer using the MDA-MB-231 and 4T1 cells. The dual-ligand system utilized two peptides targeting P-selectin and αvβ3 integrin, which are functionally linked to different stages of the development of metastatic disease at a distal site. Using in vivo multimodal imaging and post mortem histological analyses, this study shows that the dual-ligand nanoparticle effectively targeted metastatic disease that was otherwise missed by single-ligand strategies. The dual-ligand nanoparticle was capable of capturing different metastatic sites within the same animal that overexpressed either receptor or both of them. Furthermore, the highly efficient targeting resulted in 22% of the injected dual-ligand nanoparticles being deposited in early-stage metastases within 2 h after injection.

  16. Inorganic dual-layer microporous supported membranes

    DOEpatents

    Brinker, C. Jeffrey; Tsai, Chung-Yi; Lu, Yungfeng

    2003-03-25

    The present invention provides for a dual-layer inorganic microporous membrane capable of molecular sieving, and methods for production of the membranes. The inorganic microporous supported membrane includes a porous substrate which supports a first inorganic porous membrane having an average pore size of less than about 25 .ANG. and a second inorganic porous membrane coating the first inorganic membrane having an average pore size of less than about 6 .ANG.. The dual-layered membrane is produced by contacting the porous substrate with a surfactant-template polymeric sol, resulting in a surfactant sol coated membrane support. The surfactant sol coated membrane support is dried, producing a surfactant-templated polymer-coated substrate which is calcined to produce an intermediate layer surfactant-templated membrane. The intermediate layer surfactant-templated membrane is then contacted with a second polymeric sol producing a polymeric sol coated substrate which is dried producing an inorganic polymeric coated substrate. The inorganic polymeric coated substrate is then calcined producing an inorganic dual-layered microporous supported membrane in accordance with the present invention.

  17. Tunable metamaterial dual-band terahertz absorber

    NASA Astrophysics Data System (ADS)

    Luo, C. Y.; Li, Z. Z.; Guo, Z. H.; Yue, J.; Luo, Q.; Yao, G.; Ji, J.; Rao, Y. K.; Li, R. K.; Li, D.; Wang, H. X.; Yao, J. Q.; Ling, F. R.

    2015-11-01

    We report a design of a temperature controlled tunable dual band terahertz absorber. The compact single unit cell consists of two nested closed square ring resonators and a layer metallic separated by a substrate strontium titanate (STO) dielectric layer. It is found that the absorber has two distinctive absorption peaks at frequencies 0.096 THz and 0.137 THz, whose peaks are attained 97% and 75%. Cooling the absorber from 400 K to 250 K causes about 25% and 27% shift compared to the resonance frequency of room temperature, when we cooling the temperature to 150 K, we could attained both the two tunabilities exceeding 53%. The frequency tunability is owing to the variation of the dielectric constant of the low-temperature co-fired ceramic (LTCC) substrate. The mechanism of the dual band absorber is attributed to the overlapping of dual resonance frequencies, and could be demonstrated by the distributions of the electric field. The method opens up avenues for designing tunable terahertz devices in detection, imaging, and stealth technology.

  18. A Dual System Model of Preferences under Risk

    ERIC Educational Resources Information Center

    Mukherjee, Kanchan

    2010-01-01

    This article presents a dual system model (DSM) of decision making under risk and uncertainty according to which the value of a gamble is a combination of the values assigned to it independently by the affective and deliberative systems. On the basis of research on dual process theories and empirical research in Hsee and Rottenstreich (2004) and…

  19. 34 CFR 75.519 - Dual compensation of staff.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 1 2011-07-01 2011-07-01 false Dual compensation of staff. 75.519 Section 75.519... by a Grantee? Project Staff § 75.519 Dual compensation of staff. A grantee may not use its grantee to pay a project staff member for time or work for which that staff member is compensated from some other...

  20. 34 CFR 75.519 - Dual compensation of staff.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 1 2014-07-01 2014-07-01 false Dual compensation of staff. 75.519 Section 75.519... by a Grantee? Project Staff § 75.519 Dual compensation of staff. A grantee may not use its grantee to pay a project staff member for time or work for which that staff member is compensated from some other...

  1. 34 CFR 75.519 - Dual compensation of staff.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 1 2012-07-01 2012-07-01 false Dual compensation of staff. 75.519 Section 75.519... by a Grantee? Project Staff § 75.519 Dual compensation of staff. A grantee may not use its grantee to pay a project staff member for time or work for which that staff member is compensated from some other...

  2. 34 CFR 75.519 - Dual compensation of staff.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 1 2013-07-01 2013-07-01 false Dual compensation of staff. 75.519 Section 75.519... by a Grantee? Project Staff § 75.519 Dual compensation of staff. A grantee may not use its grantee to pay a project staff member for time or work for which that staff member is compensated from some other...

  3. 34 CFR 75.519 - Dual compensation of staff.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Dual compensation of staff. 75.519 Section 75.519... by a Grantee? Project Staff § 75.519 Dual compensation of staff. A grantee may not use its grantee to pay a project staff member for time or work for which that staff member is compensated from some other...

  4. Analysis of Dual Mode Systems in an Urban Area : Volume 1. Summary.

    DOT National Transportation Integrated Search

    1973-12-01

    Various forms of Dual Mode transportation were analyzed in order to assess the economic viability of the dual mode concept. Specially designed new small Dual Mode vehicles, modifications of existing automobiles, and pallet systems, all operating in c...

  5. Motor-cognitive dual-task deficits in individuals with early-mid stage Huntington disease.

    PubMed

    Fritz, Nora E; Hamana, Katy; Kelson, Mark; Rosser, Anne; Busse, Monica; Quinn, Lori

    2016-09-01

    Huntington disease (HD) results in a range of cognitive and motor impairments that progress throughout the disease stages; however, little research has evaluated specific dual-task abilities in this population, and the degree to which they may be related to functional ability. The purpose of this study was to a) examine simple and complex motor-cognitive dual-task performance in individuals with HD, b) determine relationships between dual-task walking ability and disease-specific measures of motor, cognitive and functional ability, and c) examine the relationship of dual-task measures to falls in individuals with HD. Thirty-two individuals with HD were evaluated for simple and complex dual-task ability using the Walking While Talking Test. Demographics and disease-specific measures of motor, cognitive and functional ability were also obtained. Individuals with HD had impairments in simple and complex dual-task ability. Simple dual-task walking was correlated to disease-specific motor scores as well as cognitive performance, but complex dual-task walking was correlated with total functional capacity, as well as a range of cognitive measures. Number of prospective falls was moderately-strongly correlated to dual-task measures. Our results suggest that individuals with HD have impairments in cognitive-motor dual-task ability that are related to disease progression and specifically functional ability. Dual-task measures appear to evaluate a unique construct in individuals with early to mid-stage HD, and may have value in improving the prediction of falls risk in this population. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Acquisition, Conservation, and Loss of Dual-Targeted Proteins in Land Plants1[W][OA

    PubMed Central

    Xu, Lin; Carrie, Chris; Law, Simon R.; Murcha, Monika W.; Whelan, James

    2013-01-01

    The dual-targeting ability of a variety of proteins from Physcomitrella patens, rice (Oryza sativa), and Arabidopsis (Arabidopsis thaliana) was tested to determine when dual targeting arose and to what extent it was conserved in land plants. Overall, the targeting ability of over 80 different proteins from rice and P. patens, representing 42 dual-targeted proteins in Arabidopsis, was tested. We found that dual targeting arose early in land plant evolution, as it was evident in many cases with P. patens proteins that were conserved in rice and Arabidopsis. Furthermore, we found that the acquisition of dual-targeting ability is still occurring, evident in P. patens as well as rice and Arabidopsis. The loss of dual-targeting ability appears to be rare, but does occur. Ascorbate peroxidase represents such an example. After gene duplication in rice, individual genes encode proteins that are targeted to a single organelle. Although we found that dual targeting was generally conserved, the ability to detect dual-targeted proteins differed depending on the cell types used. Furthermore, it appears that small changes in the targeting signal can result in a loss (or gain) of dual-targeting ability. Overall, examination of the targeting signals within this study did not reveal any clear patterns that would predict dual-targeting ability. The acquisition of dual-targeting ability also appears to be coordinated between proteins. Mitochondrial intermembrane space import and assembly protein40, a protein involved in oxidative folding in mitochondria and peroxisomes, provides an example where acquisition of dual targeting is accompanied by the dual targeting of substrate proteins. PMID:23257241

  7. Dual-band quantum well infrared photodetector with metallic structure

    NASA Astrophysics Data System (ADS)

    Wu, Yang; Liu, Hongmei; Li, Pingzhou

    2018-02-01

    The quantum efficiency of the dual bands quantum well infrared photodetectors(QWIP) has been widely concerned in recent years. A novel structure for the dual-band quantum well infrared detectors which is based on GaAs/AlGaAs designed in this paper is aimed to improve the absorption efficiency. The structure replaces the conventional grating with a metallic grating based on surface plasmon polaritons(SPPS), and we further insert a metal structure in the periodic quantum well layer. The simulation result shows that the use of the different shapes of the metal holes can remarkably improve the optical coupling efficiency due to the surface plasmon effect. By optimizing parameters of the structure, it can work in the dual infrared bands of 3-5um and 8-12um. Moreover, the absorption rate increased by 20% compared with traditional structure of Dual-band QWIP.

  8. On the dual equivalence of the self-dual and topologically massive /p-form models

    NASA Astrophysics Data System (ADS)

    Menezes, R.; Nascimento, J. R. S.; Ribeiro, R. F.; Wotzasek, C.

    2003-07-01

    We study the duality symmetry in p-form models containing a generalized Bq∧Fp+1 term in spacetime manifolds of arbitrary dimensions. The equivalence between the Bq∧Fp+1 self-dual (SDB∧F) and the Bq∧Fp+1 topologically massive (TMB∧F) models is established using a gauge embedding procedure, including the minimal coupling to conserved charged matter current. The minimal coupling adopted for both tensor fields in the self-dual representation is transformed into a non-minimal magnetic like coupling in the topologically massive representation but with the currents swapped. It is known that to establish this equivalence a current-current interaction term is needed to render the matter sector unchanged. We show that both terms arise naturally from the embedding adopted. Comparison with Higgs/Julia-Toulouse duality is established.

  9. Dual-readout calorimetry

    NASA Astrophysics Data System (ADS)

    Lee, Sehwook; Livan, Michele; Wigmans, Richard

    2018-04-01

    In the past 20 years, dual-readout calorimetry has emerged as a technique for measuring the properties of high-energy hadrons and hadron jets that offers considerable advantages compared with the instruments that are currently used for this purpose in experiments at the high-energy frontier. The status of this experimental technique and the challenges faced for its further development are reviewed.

  10. Adverse effects in dual-feed interferometry

    NASA Astrophysics Data System (ADS)

    Colavita, M. Mark

    2009-11-01

    Narrow-angle dual-star interferometric astrometry can provide very high accuracy in the presence of the Earth's turbulent atmosphere. However, to exploit the high atmospherically-limited accuracy requires control of systematic errors in measurement of the interferometer baseline, internal OPDs, and fringe phase. In addition, as high photometric SNR is required, care must be taken to maximize throughput and coherence to obtain high accuracy on faint stars. This article reviews the key aspects of the dual-star approach and implementation, the main contributors to the systematic error budget, and the coherence terms in the photometric error budget.

  11. Dual-Gated Motion-Frozen Cardiac PET with Flurpiridaz F 18.

    PubMed

    Slomka, Piotr J; Rubeaux, Mathieu; Le Meunier, Ludovic; Dey, Damini; Lazewatsky, Joel L; Pan, Tinsu; Dweck, Marc R; Newby, David E; Germano, Guido; Berman, Daniel S

    2015-12-01

    A novel PET radiotracer, Flurpiridaz F 18, has undergone phase II clinical trial evaluation as a high-resolution PET cardiac perfusion imaging agent. In a subgroup of patients imaged with this agent, we assessed the feasibility and benefit of simultaneous correction of respiratory and cardiac motion. In 16 patients, PET imaging was performed on a 4-ring scanner in dual cardiac and respiratory gating mode. Four sets of data were reconstructed with high-definition reconstruction (HD•PET): ungated and 8-bin electrocardiography-gated images using 5-min acquisition, optimal respiratory gating (ORG)-as developed for oncologic imaging-using a narrow range of breathing amplitude around end-expiration level with 35% of the counts in a 7-min acquisition, and 4-bin respiration-gated and 8-bin electrocardiography-gated images (32 bins in total) using the 7-min acquisition (dual-gating, using all data). Motion-frozen (MF) registration algorithms were applied to electrocardiography-gated and dual-gated data, creating cardiac-MF and dual-MF images. We computed wall thickness, wall/cavity contrast, and contrast-to-noise ratio for standard, ORG, cardiac-MF, and dual-MF images to assess image quality. The wall/cavity contrast was similar for ungated (9.3 ± 2.9) and ORG (9.5 ± 3.2) images and improved for cardiac-MF (10.8 ± 3.6) and dual-MF images (14.8 ± 8.0) (P < 0.05). The contrast-to-noise ratio was 22.2 ± 9.1 with ungated, 24.7 ± 12.2 with ORG, 35.5 ± 12.8 with cardiac-MF, and 42.1 ± 13.2 with dual-MF images (all P < 0.05). The wall thickness was significantly decreased (P < 0.05) with dual-MF (11.6 ± 1.9 mm) compared with ungated (13.9 ± 2.8 mm), ORG (13.1 ± 2.9 mm), and cardiac-MF images (12.1 ± 2.7 mm). Dual (respiratory/cardiac)-gated perfusion imaging with Flurpiridaz F 18 is feasible and improves image resolution, contrast, and contrast-to-noise ratio when MF registration methods are applied. © 2015 by the Society of Nuclear Medicine and Molecular Imaging

  12. The Grassmannian origin of dual superconformal invariance

    NASA Astrophysics Data System (ADS)

    Arkani-Hamed, Nima; Cachazo, Freddy; Cheung, Clifford

    2010-03-01

    A dual formulation of the S Matrix for mathcal {N} = 4 SYM has recently been presented, where all leading singularities of n-particle N k-2MHV amplitudes are given as an integral over the Grassmannian G( k, n), with cyclic symmetry, parity and superconformal invariance manifest. In this short note we show that the dual superconformal invariance of this object is also manifest. The geometry naturally suggests a partial integration and simple change of variable to an integral over G( k - 2, n). This change of variable precisely corresponds to the mapping between usual momentum variables and the “momentum twistors” introduced by Hodges, and yields an elementary derivation of the momentumtwistor space formula very recently presented by Mason and Skinner, which is manifestly dual superconformal invariant. Thus the G( k, n) Grassmannian formulation allows a direct understanding of all the important symmetries of mathcal {N} = 4 SYM scattering amplitudes.

  13. [Treatment program for dual-diagnosis substance abusers].

    PubMed

    Kandel, Isack

    2007-01-01

    Dual-diagnosis mentally ill patients, i.e. those characterized with substance abuse problems combined with mental health problems, are a challenge both for systems treating substance abusers and for mental health services. These patients are not easily integrated in either of these healthcare systems and/or are treated only for one aspect of their problem by each of these systems. For such patients it is necessary to create a separate treatment model, combining care of the problem of substance abuse and attention to the patient's mental pathology, according to his individual personality traits. For purposes of this programme a treatment setting operating on the model of a therapeutic community is proposed. This setting will open an affiliated treatment programme for dual-diagnosed patients in a separate treatment programme that is not part of the therapeutic community but will be affiliated with it and will accept dual-diagnosis patients.

  14. Does dual-task coordination performance decline in later life?

    PubMed

    Sebastián, María V; Mediavilla, Roberto

    2017-05-01

    This cross-sectional study examined whether changes occur in people’s capacity to coordinate two simultaneous tasks (dual-task) when transitioning from adulthood to later life. The central executive, Baddeley’s working memory model component, is responsible for this coordination. Contradictory results have been reported regarding the relationship between ageing and dual-task performance; but these seem to be related to methodological issues that have been addressed in this study. Nine hundred and seventy-two participants, aged between 35 and 90 years old, volunteered to carry out a verbal digit span task, followed by single and concurrent (dual-task) tests: first, a box crossing task, then, the digit recall task in relation to their memory span, and finally, both these tests simultaneously. We found no difference in people’s capacity to coordinate their attention when doing two tasks in adulthood or healthy later life, including those in the oldest age groups. Furthermore, gender and educational level were not related to dual-task performance. The results support the normal functioning of the central executive in very old people. These data contrast with research with patients suffering from different types of dementia, which show a decrease in their dual-task performance.

  15. Dual-Alloy Disks are Formed by Powder Metallurgy

    NASA Technical Reports Server (NTRS)

    Harf, F. H.; Miner, R. V.; Kortovich, C. S.; Marder, J. M.

    1982-01-01

    High-performance disks have widely varying properties from hub to rim. Dual property disk is fabricated using two nickel-base alloys, AF-115 for rim and Rene 95 for hub. Dual-alloy fabrication may find applications in automobiles, earth-moving equipment, and energy conversion systems as well as aircraft powerplants. There is potential for such applications as shafts, gears, and blades.

  16. Development of a dual-field heteropoplar power converter

    NASA Technical Reports Server (NTRS)

    Eisenhaure, D. B.; Johnson, B.; Bliamptis, T.; St. George, E.

    1981-01-01

    The design and testing of a 400 watt, dual phase, dual rotor, field modulated inductor alternator is described. The system is designed for use as a flywheel to ac utility line or flywheel to dc bus (electric vehicle) power converter. The machine is unique in that it uses dual rotors and separately controlled fields to produce output current and voltage which are in phase with each other. Having the voltage and current in phase allows the power electronics to be made of simple low cost components. Based on analytical predictions and experimental results, development of a complete 22 kilowatt (30 Hp) power conversion system is recommended. This system would include power electronics and controls and would replace the inductor alternator with an improved electromagnetic conversion system.

  17. Resistivity Measurement by Dual-Configuration Four-Probe Method

    NASA Astrophysics Data System (ADS)

    Yamashita, Masato; Nishii, Toshifumi; Mizutani, Hiroya

    2003-02-01

    The American Society for Testing and Materials (ASTM) Committee has published a new technique for the measurement of resistivity which is termed the dual-configuration four-probe method. The resistivity correction factor is the function of only the data which are obtained from two different electrical configurations of the four probes. The measurement of resistivity and sheet resistance are performed for graphite rectangular plates and indium tin oxide (ITO) films by the conventional four-probe method and the dual-configuration four-probe method. It is demonstrated that the dual-configuration four-probe method which includes a probe array with equal separations of 10 mm can be applied to specimens having thicknesses up to 3.7 mm if a relative resistivity difference up to 5% is allowed.

  18. Verifying Galileo's discoveries: telescope-making at the Collegio Romano

    NASA Astrophysics Data System (ADS)

    Reeves, Eileen; van Helden, Albert

    The Jesuits of the Collegio Romano in Rome, especially the mathematicians Clavius and Grienberger, were very interested in Galilei's discoveries. After they had failed to recognize with telescopes of own construction the celestial phenomena, they expressed serious doubts. But from November 1610 onward, after they had built a better telescope and had obtained from Venice another one in addition, and could verify Galilei's observations, they completely accepted them. Clavius, who stuck to the Ptolemaic system till his death in 1612, even pointed out these facts in his last edition of Sacrobosco's Sphaera. He as well as his conpatres, however, avoided any conclusions with respect to the planetary system.

  19. Dual-color two-photon fluorescence correlation spectroscopy

    NASA Astrophysics Data System (ADS)

    Berland, Keith M.

    2001-04-01

    Fluorescence correlation spectroscopy (FCS) is rapidly growing in popularity as a research tool in biological and biophysical research. Under favorable conditions, FCS measurements can produce an accurate characterization of the chemical, physical, and kinetic properties of a biological system. However, interpretation of FCS data quickly becomes complicated as the heterogeneity of a molecular system increases, as well as when there is significant non-stationery fluorescence background (e.g. intracellular autofluorescence). Use of multi-parameter correlation measurements is one promising approach that can improve the fidelity of FCS measurements in complex systems. In particular, the use of dual-color fluorescence assays, in which different interacting molecular species are labeled with unique fluorescent indicators, can "tune" the sensitivity of FCS measurements in favor of particular molecular species of interest, while simultaneously minimizing the contribution of other molecular species to the overall fluorescence correlation signal. Here we introduce the combined application of two-photon fluorescence excitation and dual-color cross-correlation analysis for detecting molecular interactions in solution. The use of two-photon excitation is particularly advantageous for dual-color FCS applications due to the uncomplicated optical alignment and the superior capabilities for intracellular applications. The theory of two-photon dual-color FCS is introduced, and initial results quantifying hybridization reactions between three independent single stranded DNA molecules are presented.

  20. Dual-Enrollment High-School Graduates' College-Enrollment Considerations

    ERIC Educational Resources Information Center

    Damrow, Roberta J.

    2017-01-01

    This quantitative study examined college enrollment considerations of dual-enrollment students enrolling at one Wisconsin credit-granting technical college. A combined college-choice theoretical framework guided this quantitative study that addressed two research questions: To what extent, if any, did the number of dual credits predict likelihood…

  1. Spatiotemporal Targeting of a Dual-Ligand Nanoparticle to Cancer Metastasis

    PubMed Central

    Doolittle, Elizabeth; Peiris, Pubudu M.; Doron, Gilad; Goldberg, Amy; Tucci, Samantha; Rao, Swetha; Shah, Shruti; Sylvestre, Meilyn; Govender, Priya; Turan, Oguz; Lee, Zhenghong; Schiemann, William P.; Karathanasis, Efstathios

    2015-01-01

    Various targeting strategies and ligands have been employed to direct nanoparticles to tumors that upregulate specific cell-surface molecules. However, tumors display a dynamic, heterogeneous microenvironment, which undergoes spatiotemporal changes including the expression of targetable cell-surface biomarkers. Here, we investigated a dual-ligand nanoparticle to effectively target two receptors overexpressed in aggressive tumors. By using two different chemical specificities, the dual-ligand strategy considered the spatiotemporal alterations in the expression patterns of the receptors in cancer sites. As a case study, we used two mouse models of metastasis of triple-negative breast cancer using the MDA-MB-231 and 4T1 cells. The dual-ligand system utilized two peptides targeting P-selectin and αvβ3 integrin, which are functionally linked to different stages of the development of metastatic disease at a distal site. Using in vivo multimodal imaging and post mortem histological analyses, this study shows that the dual-ligand nanoparticle effectively targeted metastatic disease that was otherwise missed by single-ligand strategies. The dual-ligand nanoparticle was capable of capturing different metastatic sites within the same animal that overexpressed either receptor or both of them. Furthermore, the highly efficient targeting resulted in 22% of the injected dual-ligand nanoparticles being deposited in early-stage metastases within 2 h after injection. PMID:26203676

  2. A Framework for the Dual Language Assessment of Young Dual Language Learners in the United States. Research Report. ETS RR-17-37

    ERIC Educational Resources Information Center

    Guzman-Orth, Danielle; Lopez, Alexis A.; Tolentino, Florencia

    2017-01-01

    Dual language learners (DLLs) and the various educational programs that serve them are increasing in number across the country. This framework lays out a conceptual approach for dual language assessment tasks designed to measure the language and literacy skills of young DLLs entering kindergarten in the United States. Although our examples focus…

  3. Controllable rotational inversion in nanostructures with dual chirality.

    PubMed

    Dai, Lu; Zhu, Ka-Di; Shen, Wenzhong; Huang, Xiaojiang; Zhang, Li; Goriely, Alain

    2018-04-05

    Chiral structures play an important role in natural sciences due to their great variety and potential applications. A perversion connecting two helices with opposite chirality creates a dual-chirality helical structure. In this paper, we develop a novel model to explore quantitatively the mechanical behavior of normal, binormal and transversely isotropic helical structures with dual chirality and apply these ideas to known nanostructures. It is found that both direction and amplitude of rotation can be finely controlled by designing the cross-sectional shape. A peculiar rotational inversion of overwinding followed by unwinding, observed in some gourd and cucumber tendril perversions, not only exists in transversely isotropic dual-chirality helical nanobelts, but also in the binormal/normal ones when the cross-sectional aspect ratio is close to 1. Beyond this rotational inversion region, the binormal and normal dual-chirality helical nanobelts exhibit a fixed directional rotation of unwinding and overwinding, respectively. Moreover, in the binormal case, the rotation of these helical nanobelts is nearly linear, which is promising as a possible design for linear-to-rotary motion converters. The present work suggests new designs for nanoscale devices.

  4. On the manipulability of dual cooperative robots

    NASA Technical Reports Server (NTRS)

    Chiacchio, P.; Chiaverini, S.; Sciavicco, L.; Siciliano, B.

    1989-01-01

    The definition of manipulability ellipsoids for dual robot systems is given. A suitable kineto-static formulation for dual cooperative robots is adopted which allows for a global task space description of external and internal forces, and relative velocities. The well known concepts of force and velocity manipulability ellipsoids for a single robot are formally extended and the contributions of the two single robots to the cooperative system ellipsoids are illustrated. Duality properties are discussed. A practical case study is developed.

  5. Dual Identity and Prejudice: The Moderating Role of Group Boundary Permeability

    PubMed Central

    Shi, Yuanyuan; Dang, Jianning; Zheng, Wenwen; Liu, Li

    2017-01-01

    Past work suggested that dual identity was effective to reduce prejudice. This study extended research on dual identity and prejudice by identifying a boundary condition in this relationship, that is, group permeability. In Study 1, we replicated previous studies with Chinese individuals and found that inducing dual identity (emphasizing subgroup differences and a common nation identity), compared to the control condition, decreased the urban residents’ prejudice against rural-to-urban migrants. In Study 2, we manipulated the group boundary permeability using the Hukou system reform, and found that when the group boundary was permeable, dual identity was effective in reducing prejudice against rural-to-urban migrants. However, this effect vanished in the condition where the group boundary was impermeable. These results point to the importance of inducing dual identity under specific conditions for research on decreasing prejudice. Some practical implications of the findings for urbanization and immigration are discussed. PMID:28261130

  6. Application of dual-fuel propulsion to a single stage AMLS vehicle

    NASA Technical Reports Server (NTRS)

    Lepsch, Roger A., Jr.; Stanley, Douglas O.; Unal, Resit

    1993-01-01

    As part of NASA's Advanced Manned Launch System (AMLS) study to determine a follow-on, or complement, to the Space Shuttle, a reusable single-stage-to-orbit concept utilizing dual-fuel rocket propulsion has been examined. Several dual-fuel propulsion concepts were investigated. These include: a separate engine concept combining Russian RD-170 kerosene-fueled engines with SSME-derivative engines; the kerosene and hydrogen-fueled Russian RD-701 engine concept; and a dual-fuel, dual-expander engine concept. Analysis to determine vehicle weight and size characteristics was performed using conceptual level design techniques. A response surface methodology for multidisciplinary design was utilized to optimize the dual-fuel vehicle concepts with respect to several important propulsion system and vehicle design parameters in order to achieve minimum empty weight. Comparisons were then made with a hydrogen-fueled reference, single-stage vehicle. The tools and methods employed in the analysis process are also summarized.

  7. Dual Antithrombotic Therapy with Dabigatran after PCI in Atrial Fibrillation.

    PubMed

    Cannon, Christopher P; Bhatt, Deepak L; Oldgren, Jonas; Lip, Gregory Y H; Ellis, Stephen G; Kimura, Takeshi; Maeng, Michael; Merkely, Bela; Zeymer, Uwe; Gropper, Savion; Nordaby, Matias; Kleine, Eva; Harper, Ruth; Manassie, Jenny; Januzzi, James L; Ten Berg, Jurrien M; Steg, P Gabriel; Hohnloser, Stefan H

    2017-10-19

    Triple antithrombotic therapy with warfarin plus two antiplatelet agents is the standard of care after percutaneous coronary intervention (PCI) for patients with atrial fibrillation, but this therapy is associated with a high risk of bleeding. In this multicenter trial, we randomly assigned 2725 patients with atrial fibrillation who had undergone PCI to triple therapy with warfarin plus a P2Y 12 inhibitor (clopidogrel or ticagrelor) and aspirin (for 1 to 3 months) (triple-therapy group) or dual therapy with dabigatran (110 mg or 150 mg twice daily) plus a P2Y 12 inhibitor (clopidogrel or ticagrelor) and no aspirin (110-mg and 150-mg dual-therapy groups). Outside the United States, elderly patients (≥80 years of age; ≥70 years of age in Japan) were randomly assigned to the 110-mg dual-therapy group or the triple-therapy group. The primary end point was a major or clinically relevant nonmajor bleeding event during follow-up (mean follow-up, 14 months). The trial also tested for the noninferiority of dual therapy with dabigatran (both doses combined) to triple therapy with warfarin with respect to the incidence of a composite efficacy end point of thromboembolic events (myocardial infarction, stroke, or systemic embolism), death, or unplanned revascularization. The incidence of the primary end point was 15.4% in the 110-mg dual-therapy group as compared with 26.9% in the triple-therapy group (hazard ratio, 0.52; 95% confidence interval [CI], 0.42 to 0.63; P<0.001 for noninferiority; P<0.001 for superiority) and 20.2% in the 150-mg dual-therapy group as compared with 25.7% in the corresponding triple-therapy group, which did not include elderly patients outside the United States (hazard ratio, 0.72; 95% CI, 0.58 to 0.88; P<0.001 for noninferiority). The incidence of the composite efficacy end point was 13.7% in the two dual-therapy groups combined as compared with 13.4% in the triple-therapy group (hazard ratio, 1.04; 95% CI, 0.84 to 1.29; P=0.005 for

  8. Dual renin-angiotensin-aldosterone system blockade for diabetic kidney disease.

    PubMed

    Pichler, Raimund H; de Boer, Ian H

    2010-08-01

    Blockade of the renin-angiotensin-aldosterone system (RAAS) prevents the development and progression of diabetic kidney disease (DKD). It is controversial whether the simultaneous use of two RAAS inhibitors (ie, dual RAAS blockade) further improves renal outcomes. This review examines the scientific rationale and current clinical evidence addressing the use of dual RAAS blockade to prevent and treat DKD. It is concluded that dual RAAS blockade should not be routinely applied to patients with low or moderate risk of progressive kidney disease (normoalbuminuria or microalbuminuria with preserved glomerular filtration rate). For patients with high risk of progressive kidney disease (substantial albuminuria or impaired glomerular filtration rate), clinicians should carefully weigh the potential risks and benefits of dual RAAS blockade on an individual basis until ongoing clinical trials provide further insight.

  9. Reframing Language Allocation Policy in Dual Language Bilingual Education

    ERIC Educational Resources Information Center

    Sánchez, María Teresa; García, Ofelia; Solorza, Cristian

    2018-01-01

    This article addresses language allocation policies in what is increasingly called "Dual Language Education" (DLE) in the U.S., offering a challenge to the strict language separation policies in those programs and a proposal for flexibility that transforms them into "Dual Language Bilingual Education" (DLBE). The article offers…

  10. 30 CFR 206.173 - How do I calculate the alternative methodology for dual accounting?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... measured at facility measurement points whose quality exceeds 1,000 Btu/cf are subject to dual accounting... for dual accounting? 206.173 Section 206.173 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT... the alternative methodology for dual accounting? (a) Electing a dual accounting method. (1) If you are...

  11. Better dual-task processing in simultaneous interpreters

    PubMed Central

    Strobach, Tilo; Becker, Maxi; Schubert, Torsten; Kühn, Simone

    2015-01-01

    Simultaneous interpreting (SI) is a highly complex activity and requires the performance and coordination of multiple, simultaneous tasks: analysis and understanding of the discourse in a first language, reformulating linguistic material, storing of intermediate processing steps, and language production in a second language among others. It is, however, an open issue whether persons with experience in SI possess superior skills in coordination of multiple tasks and whether they are able to transfer these skills to lab-based dual-task situations. Within the present study, we set out to explore whether interpreting experience is associated with related higher-order executive functioning in the context of dual-task situations of the Psychological Refractory Period (PRP) type. In this PRP situation, we found faster reactions times in participants with experience in simultaneous interpretation in contrast to control participants without such experience. Thus, simultaneous interpreters possess superior skills in coordination of multiple tasks in lab-based dual-task situations. PMID:26528232

  12. Dual use technology -- it's good for everyone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schario, K.

    1998-07-01

    Dual use technology is defined as technology that has both military and commercial applications. The main benefit to dual use technology is that it encourages research and development (R and D) partnerships between the government and industry that lead to the development of common products for military and commercial purposes instead of application-unique products, as in the past. Commonality, in turn, leads to better, more affordable products for all. These partnerships are cost-shared so that neither party has to bear the entire cost of development. Why is this good? Neither the military nor commercial world can afford to fully fundmore » all R and D efforts required to maintain their technological edge in the international market. How do you determine which R and D programs have enough commercial potential to motivate industry to invest in the development? This paper explores the issues involved in establishing a dual use program, and how to take advantage of the flexibility of these programs.« less

  13. A dynamic dual process model of risky decision making.

    PubMed

    Diederich, Adele; Trueblood, Jennifer S

    2018-03-01

    Many phenomena in judgment and decision making are often attributed to the interaction of 2 systems of reasoning. Although these so-called dual process theories can explain many types of behavior, they are rarely formalized as mathematical or computational models. Rather, dual process models are typically verbal theories, which are difficult to conclusively evaluate or test. In the cases in which formal (i.e., mathematical) dual process models have been proposed, they have not been quantitatively fit to experimental data and are often silent when it comes to the timing of the 2 systems. In the current article, we present a dynamic dual process model framework of risky decision making that provides an account of the timing and interaction of the 2 systems and can explain both choice and response-time data. We outline several predictions of the model, including how changes in the timing of the 2 systems as well as time pressure can influence behavior. The framework also allows us to explore different assumptions about how preferences are constructed by the 2 systems as well as the dynamic interaction of the 2 systems. In particular, we examine 3 different possible functional forms of the 2 systems and 2 possible ways the systems can interact (simultaneously or serially). We compare these dual process models with 2 single process models using risky decision making data from Guo, Trueblood, and Diederich (2017). Using this data, we find that 1 of the dual process models significantly outperforms the other models in accounting for both choices and response times. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  14. Fuel cell having dual electrode anode or cathode

    DOEpatents

    Findl, Eugene

    1985-01-01

    A fuel cell that is characterized by including a dual electrode anode that is operable to simultaneously electro-oxidize a gaseous fuel and a liquid fuel. In alternative embodiments, a fuel cell having a single electrode anode is provided with a dual electrode cathode that is operable to simultaneously reduce a gaseous oxidant and a liquid oxidant to electro-oxidize a fuel supplied to the cell.

  15. Fuel cell having dual electrode anode or cathode

    DOEpatents

    Findl, E.

    1984-04-10

    A fuel cell that is characterized by including a dual electrode anode that is operable to simultaneously electro-oxidize a gaseous fuel and a liquid fuel. In alternative embodiments, a fuel cell having a single electrode anode is provided with a dual electrode cathode that is operable to simultaneously reduce a gaseous oxidant and a liquid oxidant to electro-oxidize a fuel supplied to the cell.

  16. Spatial Distribution of Iron Within the Normal Human Liver Using Dual-Source Dual-Energy CT Imaging.

    PubMed

    Abadia, Andres F; Grant, Katharine L; Carey, Kathleen E; Bolch, Wesley E; Morin, Richard L

    2017-11-01

    Explore the potential of dual-source dual-energy (DSDE) computed tomography (CT) to retrospectively analyze the uniformity of iron distribution and establish iron concentration ranges and distribution patterns found in healthy livers. Ten mixtures consisting of an iron nitrate solution and deionized water were prepared in test tubes and scanned using a DSDE 128-slice CT system. Iron images were derived from a 3-material decomposition algorithm (optimized for the quantification of iron). A conversion factor (mg Fe/mL per Hounsfield unit) was calculated from this phantom study as the quotient of known tube concentrations and their corresponding CT values. Retrospective analysis was performed of patients who had undergone DSDE imaging for renal stones. Thirty-seven patients with normal liver function were randomly selected (mean age, 52.5 years). The examinations were processed for iron concentration. Multiple regions of interest were analyzed, and iron concentration (mg Fe/mL) and distribution was reported. The mean conversion factor obtained from the phantom study was 0.15 mg Fe/mL per Hounsfield unit. Whole-liver mean iron concentrations yielded a range of 0.0 to 2.91 mg Fe/mL, with 94.6% (35/37) of the patients exhibiting mean concentrations below 1.0 mg Fe/mL. The most important finding was that iron concentration was not uniform and patients exhibited regionally high concentrations (36/37). These regions of higher concentration were observed to be dominant in the middle-to-upper part of the liver (75%), medially (72.2%), and anteriorly (83.3%). Dual-source dual-energy CT can be used to assess the uniformity of iron distribution in healthy subjects. Applying similar techniques to unhealthy livers, future research may focus on the impact of hepatic iron content and distribution for noninvasive assessment in diseased subjects.

  17. From clinical to tissue-based dual TIA: Validation and refinement of ABCD3-I score.

    PubMed

    Dai, Qiliang; Sun, Wen; Xiong, Yunyun; Hankey, Graeme J; Xiao, Lulu; Zhu, Wusheng; Ma, Minmin; Liu, Wenhua; Liu, Dezhi; Cai, Qiankun; Han, Yunfei; Duan, Lihui; Chen, Xiangliang; Xu, Gelin; Liu, Xinfeng

    2015-04-07

    To investigate whether dual tissue-defined ischemic attacks, defined as multiple diffusion-weighted imaging lesions of different age and/or arterial territory (dual DWI), are an independent and stronger predictor of 90-day stroke than dual clinical TIAs (dual TIA). Consecutive patients with clinically defined TIA were enrolled and assessed clinically and by MRI within 3 days. The predictive ability of the ABCD clinical factors, dual TIA, and dual DWI was evaluated by means of multivariate logistic regression. Among 658 patients who were included in the study and completed 90 days of follow-up, a total of 70 patients (10.6%) experienced subsequent stroke by 90 days. Multivariate logistic regression indicated that dual DWI was an independent predictor for subsequent stroke (odds ratio 4.64, 95% confidence interval 2.15-10.01), while dual TIA was not (odds ratio 1.18, 95% confidence interval 0.69-2.01). C statistics was higher when the item of dual TIA in ABCD3-I score was replaced by dual DWI (0.759 vs 0.729, p = 0.035). The net reclassification value for 90-day stroke risk was also improved (continuous net reclassification improvement 0.301, p = 0.017). Dual DWI independently predicted future stroke in patients with TIA. A new ABCD3-I score with dual DWI instead of dual clinical TIA may improve risk stratification for early stroke risk after TIA. © 2015 American Academy of Neurology.

  18. Neural correlates of motor-cognitive dual-tasking in young and old adults

    PubMed Central

    Papegaaij, Selma; Hortobágyi, Tibor; Godde, Ben; Kaan, Wim A.; Erhard, Peter; Voelcker-Rehage, Claudia

    2017-01-01

    When two tasks are performed simultaneously, performance often declines in one or both tasks. These so-called dual-task costs are more pronounced in old than in young adults. One proposed neurological mechanism of the dual-task costs is that old compared with young adults tend to execute single-tasks with higher brain activation. In the brain regions that are needed for both tasks, the reduced residual capacity may interfere with performance of the dual-task. This competition for shared brain regions has been called structural interference. The purpose of the study was to determine whether structural interference indeed plays a role in the age-related decrease in dual-task performance. Functional magnetic resonance imaging (fMRI) was used to investigate 23 young adults (20–29 years) and 32 old adults (66–89 years) performing a calculation (serial subtraction by seven) and balance-simulation (plantar flexion force control) task separately or simultaneously. Behavioral performance decreased during the dual-task compared with the single-tasks in both age groups, with greater dual-task costs in old compared with young adults. Brain activation was significantly higher in old than young adults during all conditions. Region of interest analyses were performed on brain regions that were active in both tasks. Structural interference was apparent in the right insula, as quantified by an age-related reduction in upregulation of brain activity from single- to dual-task. However, the magnitude of upregulation did not correlate with dual-task costs. Therefore, we conclude that the greater dual-task costs in old adults were probably not due to increased structural interference. PMID:29220349

  19. Momentum-space cluster dual-fermion method

    NASA Astrophysics Data System (ADS)

    Iskakov, Sergei; Terletska, Hanna; Gull, Emanuel

    2018-03-01

    Recent years have seen the development of two types of nonlocal extensions to the single-site dynamical mean field theory. On one hand, cluster approximations, such as the dynamical cluster approximation, recover short-range momentum-dependent correlations nonperturbatively. On the other hand, diagrammatic extensions, such as the dual-fermion theory, recover long-ranged corrections perturbatively. The correct treatment of both strong short-ranged and weak long-ranged correlations within the same framework is therefore expected to lead to a quick convergence of results, and offers the potential of obtaining smooth self-energies in nonperturbative regimes of phase space. In this paper, we present an exact cluster dual-fermion method based on an expansion around the dynamical cluster approximation. Unlike previous formulations, our method does not employ a coarse-graining approximation to the interaction, which we show to be the leading source of error at high temperature, and converges to the exact result independently of the size of the underlying cluster. We illustrate the power of the method with results for the second-order cluster dual-fermion approximation to the single-particle self-energies and double occupancies.

  20. Associations of Adolescents' Cigarette, Waterpipe, and Dual Tobacco Use With Parental Tobacco Use.

    PubMed

    Veeranki, Sreenivas P; Alzyoud, Sukaina; Dierking, Leah; Kheriallah, Khalid; Mzayek, Fawaz; Pbert, Lori; Ward, Kenneth D

    2016-05-01

    Previous studies have demonstrated the influence of parental (both mother and father) cigarette smoking on adolescents' cigarette smoking. Little is known, however, about how parental tobacco use is related to waterpipe and dual waterpipe/cigarette use, which is increasing dramatically in the Arab countries. Study data (n = 34 788, N = 6 109 572) were obtained from nationally representative Global Youth Tobacco Surveys in 17 Arab countries. Study outcome was adolescents' tobacco use categorized into none, cigarette smoking only, waterpipe smoking (WPS) only, and dual use. Primary exposure included parental tobacco use categorized into 10 groups-maternal (mother) cigarette smoking only, maternal WPS only, maternal dual use, paternal (father) cigarette smoking only, paternal WPS only, paternal dual use, parental (both mother and father) cigarette smoking only, parental WPS only, parental dual use, and none. Weighted multinomial regression models were conducted to assess the relationships. Adolescents reported smoking WPS only (5.7%), cigarettes only (2.9%), and dual use (3.5%). Compared to adolescent with no exposure to parental tobacco use, adolescent exposure to parental dual use was associated with significant increase in WPS only (OR = 6.08, 95% CI = 2.38-15.51) and dual use (OR = 3.86, 95% CI = 1.43-10.43). Effect modification of the relationship by adolescents' sex was observed. This is the first study to examine adolescent cigarette, waterpipe, and dual use with parental tobacco use. Study findings may help development of cessation interventions targeting parental tobacco use to prevent the rising waterpipe and dual use strain of the global tobacco epidemic. (1) Influence of parents' cigarette smoking on adolescents' smoking has been demonstrated in earlier studies, however, little is known about how tobacco use behaviors of mother and father influences an adolescent's cigarette, waterpipe and dual cigarette/waterpipe use. (2) Associations of parental (both

  1. Dual Logic and Cerebral Coordinates for Reciprocal Interaction in Eye Contact

    PubMed Central

    Lee, Ray F.

    2015-01-01

    In order to scientifically study the human brain’s response to face-to-face social interaction, the scientific method itself needs to be reconsidered so that both quantitative observation and symbolic reasoning can be adapted to the situation where the observer is also observed. In light of the recent development of dyadic fMRI which can directly observe dyadic brain interacting in one MRI scanner, this paper aims to establish a new form of logic, dual logic, which provides a theoretical platform for deductive reasoning in a complementary dual system with emergence mechanism. Applying the dual logic in the dfMRI experimental design and data analysis, the exogenous and endogenous dual systems in the BOLD responses can be identified; the non-reciprocal responses in the dual system can be suppressed; a cerebral coordinate for reciprocal interaction can be generated. Elucidated by dual logic deductions, the cerebral coordinate for reciprocal interaction suggests: the exogenous and endogenous systems consist of the empathy network and the mentalization network respectively; the default-mode network emerges from the resting state to activation in the endogenous system during reciprocal interaction; the cingulate plays an essential role in the emergence from the exogenous system to the endogenous system. Overall, the dual logic deductions are supported by the dfMRI experimental results and are consistent with current literature. Both the theoretical framework and experimental method set the stage to formally apply the scientific method in studying complex social interaction. PMID:25885446

  2. A Continuous Dual-Process Model of Remember/Know Judgments

    ERIC Educational Resources Information Center

    Wixted, John T.; Mickes, Laura

    2010-01-01

    The dual-process theory of recognition memory holds that recognition decisions can be based on recollection or familiarity, and the remember/know procedure is widely used to investigate those 2 processes. Dual-process theory in general and the remember/know procedure in particular have been challenged by an alternative strength-based…

  3. The Complexity of Developmental Predictions from Dual Process Models

    ERIC Educational Resources Information Center

    Stanovich, Keith E.; West, Richard F.; Toplak, Maggie E.

    2011-01-01

    Drawing developmental predictions from dual-process theories is more complex than is commonly realized. Overly simplified predictions drawn from such models may lead to premature rejection of the dual process approach as one of many tools for understanding cognitive development. Misleading predictions can be avoided by paying attention to several…

  4. Dual-Process Theories and Cognitive Development: Advances and Challenges

    ERIC Educational Resources Information Center

    Barrouillet, Pierre

    2011-01-01

    Dual-process theories have gained increasing importance in psychology. The contrast that they describe between an old intuitive and a new deliberative mind seems to make these theories especially suited to account for development. Accordingly, this special issue aims at presenting the latest applications of dual-process theories to cognitive…

  5. Professional Identity and Coping Behaviors in Dual-Career Couples

    ERIC Educational Resources Information Center

    Bird, Gloria W.; Schnurman-Crook, Abrina

    2005-01-01

    This qualitative study of 15 dual-career couples examines the connection between partners' professional identity and coping behaviors implemented in response to work and family stressors. The analysis provided evidence that dual-career couples enact professional and family identities that rely on being competent and responsible in both work and…

  6. Highly coherent free-running dual-comb chip platform.

    PubMed

    Hébert, Nicolas Bourbeau; Lancaster, David G; Michaud-Belleau, Vincent; Chen, George Y; Genest, Jérôme

    2018-04-15

    We characterize the frequency noise performance of a free-running dual-comb source based on an erbium-doped glass chip running two adjacent mode-locked waveguide lasers. This compact laser platform, contained only in a 1.2 L volume, rejects common-mode environmental noise by 20 dB thanks to the proximity of the two laser cavities. Furthermore, it displays a remarkably low mutual frequency noise floor around 10  Hz 2 /Hz, which is enabled by its large-mode-area waveguides and low Kerr nonlinearity. As a result, it reaches a free-running mutual coherence time of 1 s since mode-resolved dual-comb spectra are generated even on this time scale. This design greatly simplifies dual-comb interferometers by enabling mode-resolved measurements without any phase lock.

  7. Dual waveband compact catadioptric imaging spectrometer

    DOEpatents

    Chrisp, Michael P.

    2012-12-25

    A catadioptric dual waveband imaging spectrometer that covers the visible through short-wave infrared, and the midwave infrared spectral regions, dispersing the visible through shortwave infrared with a zinc selenide grating and midwave infrared with a sapphire prism. The grating and prism are at the cold stop position, enabling the pupil to be split between them. The spectra for both wavebands are focused onto the relevant sections of a single dual waveband detector. Spatial keystone distortion is controlled to less than one tenth of a pixel over the full wavelength range, facilitating the matching of the spectra in the midwave infrared with the shorter wavelength region.

  8. Extended charge banking model of dual path shocks for implantable cardioverter defibrillators

    PubMed Central

    Dosdall, Derek J; Sweeney, James D

    2008-01-01

    Background Single path defibrillation shock methods have been improved through the use of the Charge Banking Model of defibrillation, which predicts the response of the heart to shocks as a simple resistor-capacitor (RC) circuit. While dual path defibrillation configurations have significantly reduced defibrillation thresholds, improvements to dual path defibrillation techniques have been limited to experimental observations without a practical model to aid in improving dual path defibrillation techniques. Methods The Charge Banking Model has been extended into a new Extended Charge Banking Model of defibrillation that represents small sections of the heart as separate RC circuits, uses a weighting factor based on published defibrillation shock field gradient measures, and implements a critical mass criteria to predict the relative efficacy of single and dual path defibrillation shocks. Results The new model reproduced the results from several published experimental protocols that demonstrated the relative efficacy of dual path defibrillation shocks. The model predicts that time between phases or pulses of dual path defibrillation shock configurations should be minimized to maximize shock efficacy. Discussion Through this approach the Extended Charge Banking Model predictions may be used to improve dual path and multi-pulse defibrillation techniques, which have been shown experimentally to lower defibrillation thresholds substantially. The new model may be a useful tool to help in further improving dual path and multiple pulse defibrillation techniques by predicting optimal pulse durations and shock timing parameters. PMID:18673561

  9. Dual Credit in Oregon: An Analysis of Students Taking Dual Credit in High School in 2005-06 with Subsequent Performance in College

    ERIC Educational Resources Information Center

    Jacobs, Jonathan; North, Tom

    2008-01-01

    A dual credit course is a college/university level course that is taught at a high school, by a high school teacher, in partnership with a community college (CCWD) or Oregon University System (OUS) institution. Successful completion of a dual credit course counts as credit for both high school and college. In 2005-06, about 12,000 students took…

  10. Humanity's Dual Response to Dogs and Wolves.

    PubMed

    Treves, Adrian; Bonacic, Cristian

    2016-07-01

    Dogs were first domesticated 31 000-41 000 years ago. Humanity has experienced ecological costs and benefits from interactions with dogs and wolves. We propose that humans inherited a dual response of attraction or aversion that expresses itself independently to domestic and wild canids. The dual response has had far-reaching consequences for the ecology and evolution of all three taxa, including today's global 'ecological paw print' of 1 billion dogs and recent eradications of wolves. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Dual Causality and the Autonomy of Biology.

    PubMed

    Bock, Walter J

    2017-03-01

    Ernst Mayr's concept of dual causality in biology with the two forms of causes (proximate and ultimate) continues to provide an essential foundation for the philosophy of biology. They are equivalent to functional (=proximate) and evolutionary (=ultimate) causes with both required for full biological explanations. The natural sciences can be classified into nomological, historical nomological and historical dual causality, the last including only biology. Because evolutionary causality is unique to biology and must be included for all complete biological explanations, biology is autonomous from the physical sciences.

  12. Glioma targeting and blood-brain barrier penetration by dual-targeting doxorubincin liposomes.

    PubMed

    Gao, Jian-Qing; Lv, Qing; Li, Li-Ming; Tang, Xin-Jiang; Li, Fan-Zhu; Hu, Yu-Lan; Han, Min

    2013-07-01

    Effective chemotherapy for glioblastoma requires a carrier that can penetrate the blood-brain barrier (BBB) and subsequently target the glioma cells. Dual-targeting doxorubincin (Dox) liposomes were produced by conjugating liposomes with both folate (F) and transferrin (Tf), which were proven effective in penetrating the BBB and targeting tumors, respectively. The liposome was characterized by particle size, Dox entrapment efficiency, and in vitro release profile. Drug accumulation in cells, P-glycoprotein (P-gp) expression, and drug transport across the BBB in the dual-targeting liposome group were examined by using bEnd3 BBB models. In vivo studies demonstrated that the dual-targeting Dox liposomes could transport across the BBB and mainly distribute in the brain glioma. The anti-tumor effect of the dual-targeting liposome was also demonstrated by the increased survival time, decreased tumor volume, and results of both hematoxylin-eosin staining and terminal deoxynucleotidyl transferase dUTP nick end labeling analysis. The dual-targeting Dox liposome could improve the therapeutic efficacy of brain glioma and were less toxic than the Dox solution, showing a dual-targeting effect. These results indicate that this dual-targeting liposome can be used as a potential carrier for glioma chemotherapy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Aqueous Film Forming Foam (AFFF)/Halon Dual Nozzle Test

    DTIC Science & Technology

    1991-07-01

    Aqueous Film Forming Foam ( AFFF ...nozzle from Regal Products, Inc. with the P-19 standard aqueous film forming foam ( AFFF ) and halon handline nozzles. A dual agent nozzle may have...the ergonomic properties of the test dual agent nozzle, to include ease of operation, back-pressure and comfort. Halon, aqueous film forming foam

  14. Dual-Laser-Pulse Ignition

    NASA Technical Reports Server (NTRS)

    Trinh, Huu; Early, James W.; Thomas, Matthew E.; Bossard, John A.

    2006-01-01

    A dual-pulse laser (DPL) technique has been demonstrated for generating laser-induced sparks (LIS) to ignite fuels. The technique was originally intended to be applied to the ignition of rocket propellants, but may also be applicable to ignition in terrestrial settings in which electric igniters may not be suitable.

  15. Mechanics of dual-mode dilative failure in subaqueous sediment deposits

    NASA Astrophysics Data System (ADS)

    You, Yao; Flemings, Peter; Mohrig, David

    2014-07-01

    We introduce dual-mode dilative failure with flume experiments. Dual-mode dilative failure combines slow and steady release of sediments by breaching with periodic sliding, which rapidly releases an internally coherent wedge of sediments. It occurs in dilative sandy deposits. This periodic slope failure results from cyclic evolution of the excess pore pressure in the deposit. Sliding generates large, transient, negative excess pore pressure that strengthens the deposit and allows breaching to occur. During breaching, negative excess pore pressure dissipates, the deposit weakens, and ultimately sliding occurs once again. We show that the sliding frequency is proportional to the coefficient of consolidation. We find that thicker deposits are more susceptible to dual-mode dilative failure. Discovery of dual-mode dilative failure provides a new mechanism to consider when interpreting the sedimentary deposits linked to submarine slope failures.

  16. Dual citizenship rights: do they make more and richer citizens?

    PubMed

    Mazzolari, Francesca

    2009-02-01

    In the 1990s, Colombia, the Dominican Republic, Ecuador, Costa Rica, and Brazil passed dual citizenship laws granting their expatriates the right to naturalize in the receiving country without losing their nationality of origin. I estimate the effects of these new laws on naturalization rates and labor market outcomes in the United States. Based on data from the 1990 and 2000 U.S. censuses, I find that immigrants recently granted dual nationality rights are more likely to naturalize relative to immigrants from other Latin American countries. They also experience relative employment and earnings gains, together with drops in welfare use, suggesting that dual citizenship rights not only increase the propensity to naturalize but may also promote economic assimilation. The effects of dual citizenship on improved economic performance, if mediated through naturalization, are consistent with American citizenship conferring greater economic opportunities.

  17. Changes in Standing and Walking Performance Under Dual-Task Conditions Across the Lifespan.

    PubMed

    Ruffieux, Jan; Keller, Martin; Lauber, Benedikt; Taube, Wolfgang

    2015-12-01

    Simultaneous performance of a postural and a concurrent task is rather unproblematic as long as the postural task is executed in an automatic way. However, in situations where postural control requires more central processing, cognitive resources may be exceeded by the addition of an attentionally demanding task. This may lead to interference between the two tasks, manifested in a decreased performance in one or both tasks (dual-task costs). Owing to changes in attentional demands of postural tasks as well as processing capacities across the lifespan, it might be assumed that dual-task costs are particularly pronounced in children and older adults probably leading to a U-shaped pattern for dual-task costs as a function of age. However, these changes in the ability of dual-tasking posture from childhood to old age have not yet been systematically reviewed. Therefore, Web of Science and PubMed databases were searched for studies comparing dual-task performance with one task being standing or walking in healthy groups of young adults and either children or older adults. Seventy-nine studies met inclusion criteria. For older adults, the expected increase in dual-task costs could be confirmed. In contrast, in children there was only feeble evidence for a trend towards enlarged dual-task costs. More good-quality studies comparing dual-task ability in children, young, and, ideally, also older adults within the same paradigm are needed to draw unambiguous conclusions about lifespan development of dual-task performance in postural tasks. There is evidence that, in older adults, dual-task performance can be improved by training. For the other age groups, these effects have yet to be investigated.

  18. Industrial dual arm robot manipulator for precise assembly of mechanical parts

    NASA Astrophysics Data System (ADS)

    Park, Chanhun; Kim, Doohyung; Park, Kyoungtaik; Choi, Youngjin

    2007-12-01

    A new structure of dual arm robot manipulator which consists of two industrial 6-DOF arms and one 2-DOF Torso is introduced. Each industrial 6-DOF arm is able to be used as a stand-alone industrial 6-DOF robot manipulator and as a part of dual arm manipulator at the same time. These structures help the robot maker which is willing to succeed in the emerging dual arm robot market in order to have high competition for the current industrial robot market at same time. Self-collision detection algorithm for multi-arm robot and kinematics algorithms for the developed dual arm robot manipulator which are implemented in our controller are introduced.

  19. A theoretical approach to dual practice regulations in the health sector.

    PubMed

    González, Paula; Macho-Stadler, Inés

    2013-01-01

    Internationally, there is wide cross-country heterogeneity in government responses to dual practice in the health sector. This paper provides a uniform theoretical framework to analyze and compare some of the most common regulations. We focus on three interventions: banning dual practice, offering rewarding contracts to public physicians, and limiting dual practice (including both limits to private earnings of dual providers and limits to involvement in private activities). An ancillary objective of the paper is to investigate whether regulations that are optimal for developed countries are adequate for developing countries as well. Our results offer theoretical support for the desirability of different regulations in different economic environments. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Analysis of Dual Mode Systems in an Urban Area : Volume 2. Study Results.

    DOT National Transportation Integrated Search

    1973-12-01

    Various forms of Dual Mode transportation were analyzed in order to assess the economic viability of the dual mode concept. Specially designed new small Dual Mode vehicles, modifications of existing automobiles, and pallet systems, all operating in c...

  1. Studies on biogas-fuelled compression ignition engine under dual fuel mode.

    PubMed

    Mahla, Sunil Kumar; Singla, Varun; Sandhu, Sarbjot Singh; Dhir, Amit

    2018-04-01

    Experimental investigation has been carried out to utilize biogas as an alternative source of energy in compression ignition (CI) engine under dual fuel operational mode. Biogas was inducted into the inlet manifold at different flow rates along with fresh air through inlet manifold and diesel was injected as a pilot fuel to initiate combustion under dual fuel mode. The engine performance and emission characteristics of dual fuel operational mode were analyzed at different biogas flow rates and compared with baseline conventional diesel fuel. Based upon the improved performance and lower emission characteristics under the dual fuel operation, the optimum flow rate of biogas was observed to be 2.2 kg/h. The lower brake thermal efficiency (BTE) and higher brake-specific energy consumption (BSEC) were noticed with biogas-diesel fuel under dual fuel mode when compared with neat diesel operation. Test results showed reduced NO x emissions and smoke opacity level in the exhaust tailpipe emissions. However, higher hydrocarbon (HC) and carbon monoxide (CO) emissions were noticed under dual fuel mode at entire engine loads when compared with baseline fossil petro-diesel. Hence, the use of low-cost gaseous fuel such as biogas would be an economically viable proposition to address the current and future problems of energy scarcity and associated environmental concerns.

  2. E-cigarette Dual Users, Exclusive Users and Perceptions of Tobacco Products

    PubMed Central

    Cooper, Maria; Case, Kathleen R.; Loukas, Alexandra; Creamer, MeLisa R.; Perry, Cheryl L.

    2016-01-01

    Objectives We examined differences in the characteristics of youth non-users, cigarette-only, e-cigarette-only, and dual e-cigarette and cigarette users. Methods Using weighted, representative data, logistic regression analyses were conducted to examine differences in demographic characteristics and tobacco use behaviors across tobacco usage groups. Multiple linear regression analyses were conducted to examine differences in harm perceptions of various tobacco products and perceived peer use of e-cigarettes by tobacco usage group. Results Compared to non-users, dual users were more likely to be white, male, and high school students. Dual users had significantly higher prevalence of current use of all products (except hookah) than e-cigarette-only users, and higher prevalence of current use of snus and hookah than the cigarette-only group. Dual users had significantly lower harm perceptions for all tobacco products except for e-cigarettes and hookah as compared to e-cigarette-only users. Dual users reported higher peer use of cigarettes as compared to both exclusive user groups. Conclusion Findings highlight dual users’ higher prevalence of use of most other tobacco products, their lower harm perceptions of most tobacco products compared to e-cigarette-only users, and their higher perceived peer use of cigarettes compared to exclusive users. PMID:26685819

  3. E-cigarette Dual Users, Exclusive Users and Perceptions of Tobacco Products.

    PubMed

    Cooper, Maria; Case, Kathleen R; Loukas, Alexandra; Creamer, Melisa R; Perry, Cheryl L

    2016-01-01

    We examined differences in the characteristics of youth non-users, cigarette-only, e-cigarette-only, and dual e-cigarette and cigarette users. Using weighted, representative data, logistic regression analyses were conducted to examine differences in demographic characteristics and tobacco use behaviors across tobacco usage groups. Multiple linear regression analyses were conducted to examine differences in harm perceptions of various tobacco products and perceived peer use of e-cigarettes by tobacco usage group. Compared to non-users, dual users were more likely to be white, male, and high school students. Dual users had significantly higher prevalence of current use of all products (except hookah) than e-cigarette-only users, and higher prevalence of current use of snus and hookah than the cigarette-only group. Dual users had significantly lower harm perceptions for all tobacco products except for e-cigarettes and hookah as compared to e-cigarette-only users. Dual users reported higher peer use of cigarettes as compared to both exclusive user groups. Findings highlight dual users' higher prevalence of use of most other tobacco products, their lower harm perceptions of most tobacco products compared to e-cigarette-only users, and their higher perceived peer use of cigarettes compared to exclusive users.

  4. Measuring treatment effects on dual-task performance: a framework for research and clinical practice

    PubMed Central

    Plummer, Prudence; Eskes, Gail

    2015-01-01

    The relevance of dual-task walking to everyday ambulation is widely acknowledged, and numerous studies have demonstrated that dual-task interference can significantly impact recovery of functional walking in people with neurological disorders. The magnitude and direction of dual-task interference is influenced by the interaction between the two tasks, including how individuals spontaneously prioritize their attention. Therefore, to accurately interpret and characterize dual-task interference and identify changes over time, it is imperative to evaluate single and dual-task performance in both tasks, as well as the tasks relative to each other. Yet, reciprocal dual-task effects (DTE) are frequently ignored. The purpose of this perspective paper is to present a framework for measuring treatment effects on dual-task interference, specifically taking into account the interactions between the two tasks and how this can provide information on whether overall dual-task capacity has improved or a different attentional strategy has been adopted. In discussing the clinical implications of using this framework, we provide specific examples of using this method and provide some explicit recommendations for research and clinical practice. PMID:25972801

  5. The Man of Dual Nationality.

    ERIC Educational Resources Information Center

    Abe, Yoshio

    1985-01-01

    Presents an English translation of the first few pages, set in a Japanese internment camp in the U.S. during World War II, of a Japanese novel about the problems of dual nationality and personal identity. (KH)

  6. Process for Operating a Dual-Mode Combustor

    NASA Technical Reports Server (NTRS)

    Trefny, Charles J. (Inventor); Dippold, Vance F. (Inventor)

    2017-01-01

    A new dual-mode ramjet combustor used for operation over a wide flight Mach number range is described. Subsonic combustion mode is usable to lower flight Mach numbers than current dual-mode scramjets. High speed mode is characterized by supersonic combustion in a free-jet that traverses the subsonic combustion chamber to a variable nozzle throat. Although a variable combustor exit aperture is required, the need for fuel staging to accommodate the combustion process is eliminated. Local heating from shock-boundary-layer interactions on combustor walls is also eliminated.

  7. Directional motion of impacting drops on dual-textured surfaces.

    PubMed

    Vaikuntanathan, V; Sivakumar, D

    2012-09-01

    In this work, we analyze the directional movement of impacting liquid drops on dual-textured solid surfaces comprising two different surface morphologies: a textured surface and a smooth surface. The dynamics of liquid drops impacting onto the junction line between the two parts of the dual-textured surfaces is studied experimentally for varying drop impact velocity. The dual-textured surfaces used here featured a variation in their textures' geometrical parameters as well as their surface chemistry. Two types of liquid drop differing in their surface tension were used. The impact process develops a net horizontal drop velocity towards the higher-wettability surface portion and results in a bulk movement of the impacting drop liquid. The final distance moved by the impacting drop from the junction line decreases with increasing impacting drop Weber number We. A fully theoretical model, employing a balance of forces acting at the drop contact line as well as energy conservation, is formulated to determine the variation, with We, of net horizontal drop velocity and subsequent movement of the impacting drop on the dual-textured surfaces.

  8. Building a Framework for a Dual Task Taxonomy

    PubMed Central

    McIsaac, Tara L.; Lamberg, Eric M.; Muratori, Lisa M.

    2015-01-01

    The study of dual task interference has gained increasing attention in the literature for the past 35 years, with six MEDLINE citations in 1979 growing to 351 citations indexed in 2014 and a peak of 454 cited papers in 2013. Increasingly, researchers are examining dual task cost in individuals with pathology, including those with neurodegenerative diseases. While the influence of these papers has extended from the laboratory to the clinic, the field has evolved without clear definitions of commonly used terms and with extreme variations in experimental procedures. As a result, it is difficult to examine the interference literature as a single body of work. In this paper we present a new taxonomy for classifying cognitive-motor and motor-motor interference within the study of dual task behaviors that connects traditional concepts of learning and principles of motor control with current issues of multitasking analysis. As a first step in the process we provide an operational definition of dual task, distinguishing it from a complex single task. We present this new taxonomy, inclusive of both cognitive and motor modalities, as a working model; one that we hope will generate discussion and create a framework from which one can view previous studies and develop questions of interest. PMID:25961027

  9. Dual-Modality PET/Ultrasound imaging of the Prostate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean

    2005-11-11

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should helpmore » provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.« less

  10. Dual Method Use Among a Sample of First-Year College Women

    PubMed Central

    Walsh, Jennifer L.; Fielder, Robyn L.; Carey, Kate B.; Carey, Michael P.

    2014-01-01

    CONTEXT Dual method use—using one type of contraceptive to reduce the risk of STDs and another to prevent pregnancy—is effective but understudied. No prior studies have employed an event-level approach to examining characteristics associated with dual method use among college women. METHODS In 12 consecutive monthly surveys conducted in 2009–2010, data on 1,843 vaginal intercourse events were collected from 296 first-year college women. Women reported on their use of condoms and hormonal contraceptives during all events. Multilevel regression analysis was used to assess associations between event-, month- and person-level characteristics and hormonal use and dual method use. RESULTS Women used hormonal contraceptives during 53% of events and condoms during 63%. Dual method use was reported 28% of the time, and only 14% of participants were consistent users of both methods. The likelihood of dual method use was elevated when sex partners were friends as opposed to romantic partners or ex-boyfriends, and among women who had received an STD diagnosis prior to college (odds ratios, 2.5–2.9); it also increased with level of religiosity (coefficient, 0.8). Dual use was less likely when less reliable methods were used (odds ratio, 0.2) and when women reported more months of hormonal use (0.8), were older (coefficient, −4.7) and had had a greater number of partners before college (−0.3). CONCLUSIONS A better understanding of the characteristics associated with dual method use may help in the design of potential intervention efforts. PMID:24684480

  11. Antipsychotic Treatment of Adolescent Dual Diagnosis Patients

    PubMed Central

    Price, Scott A.; Brahm, Nancy C.

    2011-01-01

    BACKGROUND A diagnosis of schizophrenia requires development of a pharmacotherapy regimen that balances many factors in the therapeutic decision-making process. Patient age and the presence or absence of comorbid chemical dependency represent two factors. Comorbid chemical dependency can have a profound impact on the successful treatment of schizophrenia, making patients with dual diagnoses of schizophrenia and chemical dependence a uniquely challenging population. There is little information regarding treatment of schizophrenia and chemical dependence in the pediatric population. Existing data from pediatric and adult populations may facilitate a well-guided and knowledgeable approach to treating pediatric dual diagnosis patients. METHODS A review of the literature for medication trials evaluating antipsychotic medication used to treat schizophrenia in childhood and adolescence as well as antipsychotic use in the treatment of the dual diagnoses of schizophrenia and chemical dependence was done. Databases for Ovid MEDLINE, PubMed, and PsycInfo were searched using the terms “addiction,” “adolescence,” “childhood,” “dual diagnosis,” “schizophrenia,” and “substance abuse.” Results were limited to English-language articles. RESULTS Seven articles were identified related to psychotic disorders and substance abuse in pediatric populations. Psychosis measurement instruments included the Brief Psychiatric Rating Scale, Positive and Negative Syndrome Scale, and Clinical Global Impression. Mean improvements were insignificant in most cases. Medication trials included clozapine, olanzapine, risperidone, and molindone. Trial safety concerns included metabolic effects, increased prolactin levels, and akathisia. One study with random assignment to olanzapine was discontinued early because of substantial weight gain without evidence of superior efficacy. Clozapine treatment was associated with more adverse drug events. CONCLUSION There is a great need for

  12. Computational Fluid Dynamics Simulation of Dual Bell Nozzle Film Cooling

    NASA Technical Reports Server (NTRS)

    Braman, Kalen; Garcia, Christian; Ruf, Joseph; Bui, Trong

    2015-01-01

    Marshall Space Flight Center (MSFC) and Armstrong Flight Research Center (AFRC) are working together to advance the technology readiness level (TRL) of the dual bell nozzle concept. Dual bell nozzles are a form of altitude compensating nozzle that consists of two connecting bell contours. At low altitude the nozzle flows fully in the first, relatively lower area ratio, nozzle. The nozzle flow separates from the wall at the inflection point which joins the two bell contours. This relatively low expansion results in higher nozzle efficiency during the low altitude portion of the launch. As ambient pressure decreases with increasing altitude, the nozzle flow will expand to fill the relatively large area ratio second nozzle. The larger area ratio of the second bell enables higher Isp during the high altitude and vacuum portions of the launch. Despite a long history of theoretical consideration and promise towards improving rocket performance, dual bell nozzles have yet to be developed for practical use and have seen only limited testing. One barrier to use of dual bell nozzles is the lack of control over the nozzle flow transition from the first bell to the second bell during operation. A method that this team is pursuing to enhance the controllability of the nozzle flow transition is manipulation of the film coolant that is injected near the inflection between the two bell contours. Computational fluid dynamics (CFD) analysis is being run to assess the degree of control over nozzle flow transition generated via manipulation of the film injection. A cold flow dual bell nozzle, without film coolant, was tested over a range of simulated altitudes in 2004 in MSFC's nozzle test facility. Both NASA centers have performed a series of simulations of that dual bell to validate their computational models. Those CFD results are compared to the experimental results within this paper. MSFC then proceeded to add film injection to the CFD grid of the dual bell nozzle. A series of

  13. Dual Cavity Scramjet Operability and Performance Study (Postprint)

    DTIC Science & Technology

    2009-08-01

    K., and Schadow, K., “ Effect of Flame-Holding Cavities on Supersonic- Combustion Performance,” Journal of Propulsion and Power, Vol. 17, No. 6, 2001...numerical approaches will be used to explore the effects of various fueling schemes for both single and dual cavities. Discrete flight conditions from... effects of adding a second cavity to a scramjet flow path, and 2) determine and analyze the performance and operability of the dual cavity for

  14. Dual task cost of walking is related to fall risk in persons with multiple sclerosis.

    PubMed

    Wajda, Douglas A; Motl, Robert W; Sosnoff, Jacob J

    2013-12-15

    Persons with multiple sclerosis (MS) commonly have walking and cognitive impairments. While walking with a simultaneous cognitive task, persons with MS experience a greater decline in walking performance than healthy controls. This change in performance is termed dual task cost or dual task interference and has been associated with fall risk in older adults. We examined whether dual task cost during walking was related to fall risk in persons with MS. Thirty-three ambulatory persons with MS performed walking tasks with and without a concurrent cognitive task (dual task condition) as well as underwent a fall risk assessment. Dual task cost was operationalized as the percent change in velocity from normal walking conditions to dual task walking conditions. Fall risk was quantified using the Physiological Profile Assessment. A Spearman correlation analysis revealed a significant positive correlation between dual task cost of walking velocity and fall risk as well as dual task cost of stride length and fall risk. Overall, the findings indicate that dual task cost is associated with fall risk and may be an important target for falls prevention strategies. © 2013.

  15. Preparation and evaluation of amoxicillin loaded dual molecularly imprinted nanoparticles for anti-Helicobacter pylori therapy.

    PubMed

    Wu, Zhihui; Hou, Jiapeng; Wang, Yuyan; Chai, Miaolin; Xiong, Yan; Lu, Weiyue; Pan, Jun

    2015-12-30

    This paper reports studies on preparation and evaluation of amoxicillin loaded dual molecularly imprinted nanoparticles (Amo/Dual-MIPs) designed for anti-H. pylori therapy. Both MNQA and AmoNa were chosen as templates to prepare Dual-MIPs using inverse microemulsion polymerization method. NQA was modified with myristic acid (MNQA) to become amphiphilic and assist in leaving NQA cavities on the surface of Dual-MIPs for H. pylori adhesion. AmoNa was applied to produce imprinting sites in Dual-MIPs for rebinding AmoNa to exert its anti-H. pylori effect. Batch rebinding test demonstrated a preferential rebinding effect of NQA toward the Dual-MIPs. In vivofluorescence imaging showed the prolonged residence time of Dual-MIPs in H. pylori infected mice stomachs after intragastric administration of nanoparticles.In vivo H. pylori clearance tests indicated Amo/Dual-MIPs had a better aniti-H. pylori effect than amoxicillin powder did. In conclusion, Amo/Dual-MIPs may provide an alternative drug delivery strategy for anti-H. pylori therapy. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Tracing Supermassive Black Hole Growth with Offset and Dual AGN

    NASA Astrophysics Data System (ADS)

    Comerford, Julia

    The growth of supermassive black holes is tied to the evolution of their host galaxies, but we are still missing a fundamental understanding of how and when supermassive black holes build up their mass. Black hole mass growth can be traced when the black holes are powered as active galactic nuclei (AGN), and AGN activity can be triggered by the stochastic accretion of gas or by gas inflows driven by galaxy mergers. Galaxy merger simulations make a series of predictions about the AGN that are triggered by mergers: (1) major mergers preferentially trigger higher-luminosity AGN, (2) minor mergers more often trigger AGN activity in one supermassive black hole while major mergers more often trigger AGN activity in both black holes in a merger, and (3) black hole mass growth peaks when the black holes approach the center (<10 kpc separations) of the merger-remnant galaxy. Observational tests of these predictions from theory have been limited by the difficulty in defining a clean observational sample of AGN in galaxy mergers and the observational challenge of spatially resolving two AGN with small (<10kpc) separations. Here we present offset and dual AGN as a new observational tool that can be used to address how and when supermassive black hole mass growth occurs. A merger of two galaxies brings two supermassive black holes together, and the two black holes exist at kpc-scale separations for 100 Myr before ultimately merging. While the black holes are at kpc-scale separations, they are known as dual AGN when both of them are fueled as AGN and offset AGN when only one is fueled as an AGN. Since offset and dual AGN only occur in galaxy mergers, by their very definition, they provide a clean observational sample of black hole mass growth in galaxy mergers. The small, kpc-scale separations of offset and dual AGN also enable an observational test of black hole fueling near the centers of merger-remnant galaxies. The full potential of offset and dual AGN for such studies of

  17. State of the art: dual-energy CT of the abdomen.

    PubMed

    Marin, Daniele; Boll, Daniel T; Mileto, Achille; Nelson, Rendon C

    2014-05-01

    Recent technologic advances in computed tomography (CT)--enabling the nearly simultaneous acquisition of clinical images using two different x-ray energy spectra--have sparked renewed interest in dual-energy CT. By interrogating the unique characteristics of different materials at different x-ray energies, dual-energy CT can be used to provide quantitative information about tissue composition, overcoming the limitations of attenuation-based conventional single-energy CT imaging. In the past few years, intensive research efforts have been devoted to exploiting the unique and powerful opportunities of dual-energy CT for a variety of clinical applications. This has led to CT protocol modifications for radiation dose reduction, improved diagnostic performance for detection and characterization of diseases, as well as image quality optimization. In this review, the authors discuss the basic principles, instrumentation and design, examples of current clinical applications in the abdomen and pelvis, and future opportunities of dual-energy CT.

  18. When dual identity becomes a liability: identity and political radicalism among migrants.

    PubMed

    Simon, Bernd; Reichert, Frank; Grabow, Olga

    2013-03-01

    This article examines the role of dual identity in political radicalism among migrants. Dual identity is defined as identification with both one's ethnocultural minority in-group and one's society of residence. We employed a longitudinal research design using members of the two largest migrant groups in Germany (Turkish migrants and Russian migrants) as participants. We reasoned that when dual identity is burdened with incompatibility between component identifications, it may foster controversial or even destructive forms of political mobilization, such as radicalism. Multiple regression analysis controlling for other influences confirmed the hypothesized moderated relationship between dual identification and sympathy for radical action. When accompanied by high, as opposed to low, perceived identity incompatibility, dual identification predicted increases in sympathy for radical action among both Turkish migrants and Russian migrants. The implications for public life in ethnically and culturally heterogeneous societies are discussed.

  19. Behavioral interventions for improving dual-method contraceptive use.

    PubMed

    Lopez, Laureen M; Stockton, Laurie L; Chen, Mario; Steiner, Markus J; Gallo, Maria F

    2014-03-30

    Dual-method contraception refers to using condoms as well as another modern method of contraception. The latter (usually non-barrier) method is commonly hormonal (e.g., oral contraceptives) or a non-hormonal intrauterine device. Use of two methods can better prevent pregnancy and the transmission of HIV and other sexually transmitted infections (STIs) compared to single-method use. Unprotected sex increases risk for disease, disability, and mortality in many areas due to the prevalence and incidence of HIV/STI. Millions of women, especially in lower-resource areas, also have an unmet need for protection against unintended pregnancy. We examined comparative studies of behavioral interventions for improving use of dual methods of contraception. Dual-method use refers to using condoms as well as another modern contraceptive method. Our intent was to identify effective interventions for preventing pregnancy as well as HIV/STI transmission. Through January 2014, we searched MEDLINE, CENTRAL, POPLINE, EMBASE, COPAC, and Open Grey. In addition, we searched ClinicalTrials.gov and ICTRP for current trials and trials with relevant data or reports. We examined reference lists of pertinent papers, including review articles, for additional reports. Studies could be either randomized or non-randomized. They examined a behavioral intervention with an educational or counseling component to encourage or improve the use of dual methods, i.e., condoms and another modern contraceptive. The intervention had to address preventing pregnancy as well as the transmission of HIV/STI. The program or service could be targeted to individuals, couples, or communities. The comparison condition could be another behavioral intervention to improve contraceptive use, usual care, other health education, or no intervention.Studies had to report use of dual methods, i.e., condoms plus another modern contraceptive method. We focused on the investigator's assessment of consistent dual-method use or use at

  20. Walking Stroop carpet: an innovative dual-task concept for detecting cognitive impairment.

    PubMed

    Perrochon, A; Kemoun, G; Watelain, E; Berthoz, A

    2013-01-01

    Several studies have reported the potential value of the dual-task concept during locomotion in clinical evaluation because cognitive decline is strongly associated with gait abnormalities. However, current dual-task tests appear to be insufficient for early diagnosis of cognitive impairment. Forty-nine subjects (young, old, with or without mild cognitive impairment) underwent cognitive evaluation (Mini-Mental State Examination, Frontal Assessment Battery, five-word test, Stroop, clock-drawing) and single-task locomotor evaluation on an electronic walkway. They were then dual-task-tested on the Walking Stroop carpet, which is an adaptation of the Stroop color-word task for locomotion. A cluster analysis, followed by an analysis of variance, was performed to assess gait parameters. Cluster analysis of gait parameters on the Walking Stroop carpet revealed an interaction between cognitive and functional abilities because it made it possible to distinguish dysexecutive cognitive fragility or decline with a sensitivity of 89% and a specificity of 94%. Locomotor abilities differed according to the group and dual-task conditions. Healthy subjects performed less well on dual-tasking under reading conditions than when they were asked to distinguish colors, whereas dysexecutive subjects had worse motor performances when they were required to dual task. The Walking Stroop carpet is a dual-task test that enables early detection of cognitive fragility that has not been revealed by traditional neuropsychological tests or single-task walking analysis.

  1. Time to and predictors of dual incontinence in older nursing home admissions.

    PubMed

    Bliss, Donna Z; Gurvich, Olga V; Eberly, Lynn E; Harms, Susan

    2018-01-01

    There are few studies of nursing home residents that have investigated the development of dual incontinence, perhaps the most severe type of incontinence as both urinary and fecal incontinence occur. To determine the time to and predictors of dual incontinence in older nursing home residents. Using a cohort design, records of older nursing home admissions who were continent or had only urinary or only fecal incontinence (n = 39,181) were followed forward for report of dual incontinence. Four national US datasets containing potential predictors at multiple levels describing characteristics of nursing home residents, nursing homes (n = 445), and socioeconomic and sociodemographic status of the community surrounding nursing homes were analyzed. A Cox proportional hazard regression with nursing home-specific random effect was used. At 6 months after admission, 28% of nursing home residents developed dual incontinence, at 1 year 42% did so, and at 2 years, 61% had dual incontinence. Significant predictors for time to developing dual incontinence were having urinary incontinence, greater functional or cognitive deficits, more comorbidities, older age, and lesser quality of nursing home care. The development of dual incontinence is a major problem among nursing home residents. Predictors in this study offer guidance in developing interventions to prevent and reduce the time to developing this problem which may improve the quality of life of nursing residents. © 2017 Wiley Periodicals, Inc.

  2. Dual Coding in Children.

    ERIC Educational Resources Information Center

    Burton, John K.; Wildman, Terry M.

    The purpose of this study was to test the applicability of the dual coding hypothesis to children's recall performance. The hypothesis predicts that visual interference will have a small effect on the recall of visually presented words or pictures, but that acoustic interference will cause a decline in recall of visually presented words and…

  3. Implementation and applications of dual-modality imaging

    NASA Astrophysics Data System (ADS)

    Hasegawa, Bruce H.; Barber, William C.; Funk, Tobias; Hwang, Andrew B.; Taylor, Carmen; Sun, Mingshan; Seo, Youngho

    2004-06-01

    In medical diagnosis, functional or physiological data can be acquired using radionuclide imaging with positron emission tomography or with single-photon emission computed tomography. However, anatomical or structural data can be acquired using X-ray computed tomography. In dual-modality imaging, both radionuclide and X-ray detectors are incorporated in an imaging system to allow both functional and structural data to be acquired in a single procedure without removing the patient from the imaging system. In a clinical setting, dual-modality imaging systems commonly are used to localize radiopharmaceutical uptake with respect to the patient's anatomy. This helps the clinician to differentiate disease from regions of normal radiopharmaceutical accumulation, to improve diagnosis or cancer staging, or to facilitate planning for radiation therapy or surgery. While initial applications of dual-modality imaging were developed for clinical imaging on humans, it now is recognized that these systems have potentially important applications for imaging small animals involved in experimental studies including basic investigations of mammalian biology and development of new pharmaceuticals for diagnosis or treatment of disease.

  4. Dual-function antibacterial surfaces for biomedical applications.

    PubMed

    Yu, Qian; Wu, Zhaoqiang; Chen, Hong

    2015-04-01

    Bacterial attachment and the subsequent formation of biofilm on surfaces of synthetic materials pose a serious problem in both human healthcare and industrial applications. In recent decades, considerable attention has been paid to developing antibacterial surfaces to reduce the extent of initial bacterial attachment and thereby to prevent subsequent biofilm formation. Briefly, there are three main types of antibacterial surfaces: bactericidal surfaces, bacteria-resistant surfaces, and bacteria-release surfaces. The strategy adopted to develop each type of surface has inherent advantages and disadvantages; many efforts have been focused on the development of novel antibacterial surfaces with dual functionality. In this review, we highlight the recent progress made in the development of dual-function antibacterial surfaces for biomedical applications. These surfaces are based on the combination of two strategies into one system, which can kill attached bacteria as well as resisting or releasing bacteria. Perspectives on future research directions for the design of dual-function antibacterial surfaces are also provided. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  5. Dual learning processes in interactive skill acquisition.

    PubMed

    Fu, Wai-Tat; Anderson, John R

    2008-06-01

    Acquisition of interactive skills involves the use of internal and external cues. Experiment 1 showed that when actions were interdependent, learning was effective with and without external cues in the single-task condition but was effective only with the presence of external cues in the dual-task condition. In the dual-task condition, actions closer to the feedback were learned faster than actions farther away but this difference was reversed in the single-task condition. Experiment 2 tested how knowledge acquired in single and dual-task conditions would transfer to a new reward structure. Results confirmed the two forms of learning mediated by the secondary task: A declarative memory encoding process that simultaneously assigned credits to actions and a reinforcement-learning process that slowly propagated credits backward from the feedback. The results showed that both forms of learning were engaged during training, but only at the response selection stage, one form of knowledge may dominate over the other depending on the availability of attentional resources. (c) 2008 APA, all rights reserved

  6. Investigations into dual-grating THz-driven accelerators

    NASA Astrophysics Data System (ADS)

    Wei, Y.; Ischebeck, R.; Dehler, M.; Ferrari, E.; Hiller, N.; Jamison, S.; Xia, G.; Hanahoe, K.; Li, Y.; Smith, J. D. A.; Welsch, C. P.

    2018-01-01

    Advanced acceleration technologies are receiving considerable interest in order to miniaturize future particle accelerators. One such technology is the dual-grating dielectric structures, which can support accelerating fields one to two orders of magnitude higher than the metal RF cavities in conventional accelerators. This opens up the possibility of enabling high accelerating gradients of up to several GV/m. This paper investigates numerically a quartz dual-grating structure which is driven by THz pulses to accelerate electrons. Geometry optimizations are carried out to achieve the trade-offs between accelerating gradient and vacuum channel gap. A realistic electron bunch available from the future Compact Linear Accelerator for Research and Applications (CLARA) is loaded into an optimized 100-period dual-grating structure for a detailed wakefield study. A THz pulse is then employed to interact with this CLARA bunch in the optimized structure. The computed beam quality is analyzed in terms of emittance, energy spread and loaded accelerating gradient. The simulations show that an accelerating gradient of 348 ± 12 MV/m with an emittance growth of 3.0% can be obtained.

  7. Dual fuel injection piggyback controller system

    NASA Astrophysics Data System (ADS)

    Muji, Siti Zarina Mohd.; Hassanal, Muhammad Amirul Hafeez; Lee, Chua King; Fawzi, Mas; Zulkifli, Fathul Hakim

    2017-09-01

    Dual-fuel injection is an effort to reduce the dependency on diesel and gasoline fuel. Generally, there are two approaches to implement the dual-fuel injection in car system. The first approach is changing the whole injector of the car engine, the consequence is excessive high cost. Alternatively, it also can be achieved by manipulating the system's control signal especially the Electronic Control Unit (ECU) signal. Hence, the study focuses to develop a dual injection timing controller system that likely adopted to control injection time and quantity of compressed natural gas (CNG) and diesel fuel. In this system, Raspberry Pi 3 reacts as main controller unit to receive ECU signal, analyze it and then manipulate its duty cycle to be fed into the Electronic Driver Unit (EDU). The manipulation has changed the duty cycle to two pulses instead of single pulse. A particular pulse mainly used to control injection of diesel fuel and another pulse controls injection of Compressed Natural Gas (CNG). The test indicated promising results that the system can be implemented in the car as piggyback system. This article, which was originally published online on 14 September 2017, contained an error in the acknowledgment section. The corrected acknowledgment appears in the Corrigendum attached to the pdf.

  8. Dual fluorescence of syringaldazine

    NASA Astrophysics Data System (ADS)

    Rajendiran, N.; Balasubramanian, T.

    2007-11-01

    The absorption and fluorescence spectra of syringaldazine (SYAZ) has been recorded in solvents of different polarity, pH and β-cyclodextrin (β-CD) and compared with syringaldehyde (SYAL). The inclusion complex of SYAZ with β-CD is investigated by UV-vis, fluorimetry, AM 1, FT-IR, 1H NMR and scanning electron microscope (SEM). Δ G value suggests the inclusion process is an exothermic and spontaneous. In all solvents a dual fluorescence is observed for SYAZ, whereas, SYAL shows a dual luminescence only in polar solvents. The excitation spectra for the 410 nm is different from 340 nm indicate two different species present in this molecule. In pH solutions: (i) a large red shifted maxima is observed in the dianion and is due to large interactions between the aromatic ring and (ii) the large blue shift at pH ˜4.5, is due to dissociation of azine group and formation of aldehyde. β-CD studies reveal that, SYAZ forms a 1:2 complex from 1:1 complex with β-CD.

  9. Theoretical simulation of the dual-heat-flux method in deep body temperature measurements.

    PubMed

    Huang, Ming; Chen, Wenxi

    2010-01-01

    Deep body temperature reveals individual physiological states, and is important in patient monitoring and chronobiological studies. An innovative dual-heat-flux method has been shown experimentally to be competitive with the conventional zero-heat-flow method in its performance, in terms of measurement accuracy and step response to changes in the deep temperature. We have utilized a finite element method to model and simulate the dynamic process of a dual-heat-flux probe in deep body temperature measurements to validate the fundamental principles of the dual-heat-flux method theoretically, and to acquire a detailed quantitative description of the thermal profile of the dual-heat-flux probe. The simulation results show that the estimated deep body temperature is influenced by the ambient temperature (linearly, at a maximum rate of 0.03 °C/°C) and the blood perfusion rate. The corresponding depth of the estimated temperature in the skin and subcutaneous tissue layer is consistent when using the dual-heat-flux probe. Insights in improving the performance of the dual-heat-flux method were discussed for further studies of dual-heat-flux probes, taking into account structural and geometric considerations.

  10. Dual- versus single-coil implantable defibrillator leads: review of the literature.

    PubMed

    Neuzner, Jörg; Carlsson, Jörg

    2012-04-01

    The preferred use of dual-coil implantable defibrillator lead systems in current implantable defibrillator therapy is likely based on data showing statistically lower defibrillation thresholds with dual-coil defibrillator lead systems. The following review will summarize the clinical data for dual- versus single-coil defibrillator leads in the left and right pectoral implant locations, and will then discuss the clinical implications of single- versus dual-coil usage for atrial defibrillation, venous complications, and the risks associated with lead extraction. It will be noted that there are no comparative clinical studies on the use and outcomes of single- versus dual-coil lead systems in implantable defibrillator therapy over a long-term follow-up. The limited long-term reliability of defibrillator leads is a major concern in implantable defibrillator and cardiac resynchronization therapy. A simpler single-coil defibrillator lead system may improve the long-term performance of implanted leads. Furthermore, the superior vena cava coil is suspected to increase interventional risk in transvenous lead extraction. Therefore, the need for objective data on extractions and complications will be emphasized.

  11. The astronomer Christoph Grienberger and the Galilei trial. (German Title: Der Astronom Christoph Grienberger und der Galilei-Prozess)

    NASA Astrophysics Data System (ADS)

    Daxecker, Franz

    Christopher Grienberger was born on July 2, 1561 in Hall in Tyrol, Austria. In 1580 he joined the Society of Jesus (Jesuits). Grienberger studied in Prague and Vienna and succeeded his tutor, Christopher Clavius, as a professor of mathematics at the Roman College. Grienberger gave lectures in astronomy in order to prepare fellow Jesuits for their missionary work in China and constructed the equatorial set-up of the telescope. Among his works is a list of fixed stars, and he even worked in the science of optics. Grienberger sympathized with Galileo's theory of motion but was told to defend the Aristotelian view by the Father General of the Jesuits, Claudio Aquaviva. Grienberger died on March 11, 1636, and is buried in Rome.

  12. Quantum dual signature scheme based on coherent states with entanglement swapping

    NASA Astrophysics Data System (ADS)

    Liu, Jia-Li; Shi, Rong-Hua; Shi, Jin-Jing; Lv, Ge-Li; Guo, Ying

    2016-08-01

    A novel quantum dual signature scheme, which combines two signed messages expected to be sent to two diverse receivers Bob and Charlie, is designed by applying entanglement swapping with coherent states. The signatory Alice signs two different messages with unitary operations (corresponding to the secret keys) and applies entanglement swapping to generate a quantum dual signature. The dual signature is firstly sent to the verifier Bob who extracts and verifies the signature of one message and transmits the rest of the dual signature to the verifier Charlie who verifies the signature of the other message. The transmission of the dual signature is realized with quantum teleportation of coherent states. The analysis shows that the security of secret keys and the security criteria of the signature protocol can be greatly guaranteed. An extensional multi-party quantum dual signature scheme which considers the case with more than three participants is also proposed in this paper and this scheme can remain secure. The proposed schemes are completely suited for the quantum communication network including multiple participants and can be applied to the e-commerce system which requires a secure payment among the customer, business and bank. Project supported by the National Natural Science Foundation of China (Grant Nos. 61272495, 61379153, and 61401519) and the Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20130162110012).

  13. A cognitive dual task affects gait variability in patients suffering from chronic low back pain.

    PubMed

    Hamacher, Dennis; Hamacher, Daniel; Schega, Lutz

    2014-11-01

    Chronic pain and gait variability in a dual-task situation are both associated with higher risk of falling. Executive functions regulate (dual-task) gait variability. A possible cause explaining why chronic pain increases risk of falling in an everyday dual-task situation might be that pain interferes with executive functions and results in a diminished dual-task capability with performance decrements on the secondary task. The main goal of this experiment was to evaluate the specific effects of a cognitive dual task on gait variability in chronic low back pain (CLBP) patients. Twelve healthy participants and twelve patients suffering from CLBP were included. The subjects were asked to perform a cognitive single task, a walking single task and a motor-cognitive dual task. Stride variability of trunk movements was calculated. A two-way ANOVA was performed to compare single-task walking with dual-task walking and the single cognitive task performance with the motor-cognitive dual-task performance. We did not find any differences in both of the single-task performances between groups. However, regarding single-task walking and dual-task walking, we observed an interaction effect indicating that low back pain patients show significantly higher gait variability in the dual-task condition as compared to controls. Our data suggest that chronic pain reduces motor-cognitive dual-task performance capability. We postulate that the detrimental effects are caused by central mechanisms where pain interferes with executive functions which, in turn, might contribute to increased risk of falling.

  14. Brain activations during bimodal dual tasks depend on the nature and combination of component tasks

    PubMed Central

    Salo, Emma; Rinne, Teemu; Salonen, Oili; Alho, Kimmo

    2015-01-01

    We used functional magnetic resonance imaging to investigate brain activations during nine different dual tasks in which the participants were required to simultaneously attend to concurrent streams of spoken syllables and written letters. They performed a phonological, spatial or “simple” (speaker-gender or font-shade) discrimination task within each modality. We expected to find activations associated specifically with dual tasking especially in the frontal and parietal cortices. However, no brain areas showed systematic dual task enhancements common for all dual tasks. Further analysis revealed that dual tasks including component tasks that were according to Baddeley's model “modality atypical,” that is, the auditory spatial task or the visual phonological task, were not associated with enhanced frontal activity. In contrast, for other dual tasks, activity specifically associated with dual tasking was found in the left or bilateral frontal cortices. Enhanced activation in parietal areas, however, appeared not to be specifically associated with dual tasking per se, but rather with intermodal attention switching. We also expected effects of dual tasking in left frontal supramodal phonological processing areas when both component tasks required phonological processing and in right parietal supramodal spatial processing areas when both tasks required spatial processing. However, no such effects were found during these dual tasks compared with their component tasks performed separately. Taken together, the current results indicate that activations during dual tasks depend in a complex manner on specific demands of component tasks. PMID:25767443

  15. Dual-task testing to predict falls in community-dwelling older adults: a systematic review.

    PubMed

    Muir-Hunter, S W; Wittwer, J E

    2016-03-01

    Cognitive impairment increases fall risk in older adults. Dual-task testing is an accepted way to assess the interaction between cognition and mobility; however, there is a lack of evidence-based recommendations for dual-task testing to evaluate fall risk in clinical practice. To evaluate the association between dual-task testing protocols and future fall risk, and to identify the specific dual-task test protocols associated with elevated risk. MEDLINE, Pubmed and EMBASE electronic databases were searched from January 1988 to September 2013. Two independent raters identified prospective cohort studies (duration of at least 1 year) of dual-task assessment in community-dwelling participants aged ≥60 years, with 'falls' as the primary outcome. Methodological quality was scored independently by two raters using a published checklist of criteria for evaluating threats to the validity of observational studies. Deterioration in gait during dual-task testing compared with single-task performance was associated with increased fall risk. Shortcomings within the literature significantly limit knowledge translation of dual-task gait protocols into clinical practice. There is a paucity of prospective studies on the association of dual-task gait assessment with fall risk. Changes in gait under dual-task testing are associated with future fall risk, and this association is stronger than that for single-task conditions. Limitations in the available literature preclude development of detailed recommendations for dual-task gait testing procedures in clinical practice to identify and stratify fall risk in older adults. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  16. Dual Kidney Transplantation: Is It Worth It?

    PubMed

    Snanoudj, Renaud; Timsit, Marc-Olivier; Rabant, Marion; Tinel, Claire; Lazareth, Hélène; Lamhaut, Lionel; Martinez, Frank; Legendre, Christophe

    2017-03-01

    Use of expanded criteria donor (ECD) kidneys, which are associated with a reduced graft survival rate, has become widely adopted in elderly recipients in an old-to-old allocation system. However, the results are frequently unsatisfactory, and a high proportion of these ECD kidneys are discarded. Dual kidney transplantation (DKT) is an underused way to expand the pool of ECD kidneys and to rapidly transplant elderly patients with satisfactory results because of the transplantation of double the nephronic mass. In this overview, we summarize the results of the main studies on DKT. DKT suffers from a prejudice of heaviness and is considered to be useless by transplant centers that do not perform it. The literature is often biased by the heterogeneity of the criteria leading to a DKT and the common refusal of kidneys that are judged too marginal. In fact, we show that when strictly allocated according to reliable clinical or histological scores, dual and single ECD transplantations yield similar results in terms of patient and graft survival rates despite significant differences in donors' characteristics. DKTs are not associated with a higher proportion of surgical complications, except in some studies showing thrombosis of 1 of the 2 grafts. The benefits of dual transplantation are particularly evident for kidneys coming from most ECDs. There is still a need for more studies to find the best allocation criteria that would permit transplantation to the highest number of patients with similar outcomes in recipients of single and dual ECD kidneys.

  17. Performance of a dual anode nickel-hydrogen cell

    NASA Technical Reports Server (NTRS)

    Gahn, Randall F.

    1991-01-01

    An experimental study was conducted to characterize the voltage performance of a nickel hydrogen cell containing a hydrogen electrode on both sides of the nickel electrode. The dual anode cell was compared with a convenient single anode cell using the same nickel electrode. Higher discharge voltages and lower charge voltages were obtained with the dual anode cell during constant current discharges to 10C, pulse discharges to 8C, and polarization measurements at 50 percent of charge.

  18. The Philosophy and Feasibility of Dual Readout Calorimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hauptman, John

    2006-10-27

    I will discuss the general physical ideas behind dual-readout calorimetry, their implementation in DREAM (Dual REAdout Module) with exact separation of scintillation and Cerenkov light, implementation with mixed light in DREAM fibers, anticipated implementation in PbWO4 crystals with applications to the 4th Concept detector and to CMS, use in high energy gamma-ray and cosmic ray astrophysics with Cerenkov and N2 fluorescent light, and implementation in the 4th Concept detector for muon identification.

  19. Dual-spin attitude control for outer planet missions

    NASA Technical Reports Server (NTRS)

    Ward, R. S.; Tauke, G. J.

    1977-01-01

    The applicability of dual-spin technology to a Jupiter orbiter with probe mission was investigated. Basic mission and system level attitude control requirements were established and preliminary mechanization and control concepts developed. A comprehensive 18-degree-of-freedom digital simulation was utilized extensively to establish control laws, study dynamic interactions, and determined key sensitivities. Fundamental system/subsystem constraints were identified, and the applicability of dual-spin technology to a Jupiter orbiter with probe mission was validated.

  20. Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter.

    PubMed

    Kim, Jin Woo; Kim, Byung Moon; Park, Keun Young; Kim, Dong Joon; Kim, Dong Ik

    2016-05-01

    Utilization of a dual-lumen balloon may improve Onyx penetration into isolated dural arteriovenous fistulas (i-DAVFs). To compare the results of Onyx embolization using a dual-lumen balloon with those using a non-balloon catheter for i-DAVFs. Twenty-nine patients underwent Onyx embolization for i-DAVFs using a non-balloon (n = 14) or a dual-lumen balloon catheter (n = 15). Since its introduction, a dual-lumen balloon catheter has been preferred. We compared the dual-lumen balloon group with the non-balloon catheter group regarding angiographic outcome, treatment-related complications, total procedural time, Onyx injection time, and the number of feeders requiring embolization. The dual-lumen balloon group showed complete occlusion of i-DAVFs in 13 and near-complete in 2 patients, while the non-balloon group showed complete occlusion in 5, near-complete in 5, and incomplete in 4 patients (P < .05). Treatment-related complications occurred in 2 patients: 1 in the non-balloon group and 1 in the dual-lumen balloon group. The mean total procedural time was 62 ± 32 minutes in the dual-lumen balloon and 171 ± 88 minutes in the non-balloon group (P < .05). The mean Onyx injection time was 10 ± 6 minutes in the dual-lumen balloon and 49 ± 32 minutes in the non-balloon group (P < .05). The median number of feeders requiring embolization was 1 (range, 1-3) in the dual-lumen balloon and 2 (range, 1-4) in the non-balloon group (P < .05). Utilization of a dual-lumen balloon catheter for Onyx embolization of i-DAVF seemed to significantly increase the immediate complete occlusion rate and decrease total procedural time, Onyx injection time, and number of feeders requiring embolization.

  1. Costs and energy efficiency of a dual-mode system

    NASA Technical Reports Server (NTRS)

    Heft, R. C.

    1977-01-01

    The life cycle costs of a dual mode system for both public and semiprivate ownership are examined, and the costs in terms of levelized required revenue per passenger mile are presented. The energy use of the dual mode vehicle is analyzed by means of a detailed vehicle simulation program for the control policy and guideway system. Several different propulsion systems are considered.

  2. The Neurocognitive Basis for Impaired Dual-Task Performance in Senior Fallers.

    PubMed

    Nagamatsu, Lindsay S; Hsu, C Liang; Voss, Michelle W; Chan, Alison; Bolandzadeh, Niousha; Handy, Todd C; Graf, Peter; Beattie, B Lynn; Liu-Ambrose, Teresa

    2016-01-01

    Falls are a major health-care concern, and while dual-task performance is widely recognized as being impaired in those at-risk for falls, the underlying neurocognitive mechanisms remain unknown. A better understanding of the underlying mechanisms could lead to the refinement and development of behavioral, cognitive, or neuropharmacological interventions for falls prevention. Therefore, we conducted a cross-sectional study with community-dwelling older adults aged 70-80 years with a history of falls (i.e., two or more falls in the past 12 months) or no history of falls (i.e., zero falls in the past 12 months); n = 28 per group. We compared functional activation during cognitive-based dual-task performance between fallers and non-fallers using functional magnetic resonance imaging (fMRI). Executive cognitive functioning was assessed via Stroop, Trail Making, and Digit Span. Mobility was assessed via the Timed Up and Go test (TUG). We found that non-fallers exhibited significantly greater functional activation compared with fallers during dual-task performance in key regions responsible for resolving dual-task interference, including precentral, postcentral, and lingual gyri. Further, we report slower reaction times during dual-task performance in fallers and significant correlations between level of functional activation and independent measures of executive cognitive functioning and mobility. Our study is the first neuroimaging study to examine dual-task performance in fallers, and supports the notion that fallers have reduced functional brain activation compared with non-fallers. Given that dual-task performance-and the underlying neural concomitants-appears to be malleable with relevant training, our study serves as a launching point for promising strategies to reduce falls in the future.

  3. Persistency and flexibility of complex brain networks underlie dual-task interference.

    PubMed

    Alavash, Mohsen; Hilgetag, Claus C; Thiel, Christiane M; Gießing, Carsten

    2015-09-01

    Previous studies on multitasking suggest that performance decline during concurrent task processing arises from interfering brain modules. Here, we used graph-theoretical network analysis to define functional brain modules and relate the modular organization of complex brain networks to behavioral dual-task costs. Based on resting-state and task fMRI we explored two organizational aspects potentially associated with behavioral interference when human subjects performed a visuospatial and speech task simultaneously: the topological overlap between persistent single-task modules, and the flexibility of single-task modules in adaptation to the dual-task condition. Participants showed a significant decline in visuospatial accuracy in the dual-task compared with single visuospatial task. Global analysis of topological similarity between modules revealed that the overlap between single-task modules significantly correlated with the decline in visuospatial accuracy. Subjects with larger overlap between single-task modules showed higher behavioral interference. Furthermore, lower flexible reconfiguration of single-task modules in adaptation to the dual-task condition significantly correlated with larger decline in visuospatial accuracy. Subjects with lower modular flexibility showed higher behavioral interference. At the regional level, higher overlap between single-task modules and less modular flexibility in the somatomotor cortex positively correlated with the decline in visuospatial accuracy. Additionally, higher modular flexibility in cingulate and frontal control areas and lower flexibility in right-lateralized nodes comprising the middle occipital and superior temporal gyri supported dual-tasking. Our results suggest that persistency and flexibility of brain modules are important determinants of dual-task costs. We conclude that efficient dual-tasking benefits from a specific balance between flexibility and rigidity of functional brain modules. © 2015 Wiley

  4. Optimum allocation for a dual-frame telephone survey.

    PubMed

    Wolter, Kirk M; Tao, Xian; Montgomery, Robert; Smith, Philip J

    2015-12-01

    Careful design of a dual-frame random digit dial (RDD) telephone survey requires selecting from among many options that have varying impacts on cost, precision, and coverage in order to obtain the best possible implementation of the study goals. One such consideration is whether to screen cell-phone households in order to interview cell-phone only (CPO) households and exclude dual-user household, or to take all interviews obtained via the cell-phone sample. We present a framework in which to consider the tradeoffs between these two options and a method to select the optimal design. We derive and discuss the optimum allocation of sample size between the two sampling frames and explore the choice of optimum p , the mixing parameter for the dual-user domain. We illustrate our methods using the National Immunization Survey , sponsored by the Centers for Disease Control and Prevention.

  5. Dual Solutions for Nonlinear Flow Using Lie Group Analysis

    PubMed Central

    Awais, Muhammad; Hayat, Tasawar; Irum, Sania; Saleem, Salman

    2015-01-01

    `The aim of this analysis is to investigate the existence of the dual solutions for magnetohydrodynamic (MHD) flow of an upper-convected Maxwell (UCM) fluid over a porous shrinking wall. We have employed the Lie group analysis for the simplification of the nonlinear differential system and computed the absolute invariants explicitly. An efficient numerical technique namely the shooting method has been employed for the constructions of solutions. Dual solutions are computed for velocity profile of an upper-convected Maxwell (UCM) fluid flow. Plots reflecting the impact of dual solutions for the variations of Deborah number, Hartman number, wall mass transfer are presented and analyzed. Streamlines are also plotted for the wall mass transfer effects when suction and blowing situations are considered. PMID:26575996

  6. All dual mobility cups are not the same.

    PubMed

    Aslanian, Thierry

    2017-03-01

    Although the natural history of dual mobility has been exclusively borne for 20 years by a single company (due to industrial ownership), the concept has undeniably been very widely popularised with nearly 40 cups on the French market which should be regarded as a weight bearing surface, both broadly and in their own right. However, within the same original idea, these implants are not all identical (design, material, fixation ect.).The aim of this work is to propose a classification of different dual mobility cups by distinguishing between thegeneral characteristics of a conventional cup and those particular to this type of implant. By comparison with a standard metal-back cup, dual mobility is based on at least one additional interface corresponding to the mobility of the polyethylene insert in the concavity of the acetabular cup called the outersurface. Design, constitutive material, fixation of the cup and characteristics of the retentive insert are analysed through the published results. The complications associated, in particular, the intraprosthetic dislocation and to a lesser extent fixation failures undoubtedly condemned the dissemination of the dual mobility concept, as witnessed by the fact that despite the precedence of this 40-year old concept, the overriding majority of publications (more than 95%) have only appeared in the last ten years. The latest generation of dual mobility cups combines: 1) a cast chrome-cobalt alloy cup covered with a bilayer coating of porous titanium and hydroxyapatite for long-term press-fit fixation to 2) an insert designed to eliminate all of the risks of intraprosthetic dislocation, whilst keeping all of the elasticity properties of the polyethylene, which has demonstrated its medium and long term effectiveness on preventing instability by overcoming other complications.

  7. Dual beam optical interferometer

    NASA Technical Reports Server (NTRS)

    Gutierrez, Roman C. (Inventor)

    2003-01-01

    A dual beam interferometer device is disclosed that enables moving an optics module in a direction, which changes the path lengths of two beams of light. The two beams reflect off a surface of an object and generate different speckle patterns detected by an element, such as a camera. The camera detects a characteristic of the surface.

  8. Application and Discussion of Dual Fluidized Bed Reactor in Biomass Energy Utilization

    NASA Astrophysics Data System (ADS)

    Guan, Haibin; Fan, Xiaoxu; Zhao, Baofeng; Yang, Liguo; Sun, Rongfeng

    2018-01-01

    As an important clean and renewable energy, biomass has a broad market prospect. The dual fluidized bed is widely used in biomass gasification technology, and has become an important way of biomass high-value utilization. This paper describes the basic principle of dual fluidized bed gasification, from the gas composition, tar content and thermal efficiency of the system point of view, analyzes and summarizes several typical dual fluidized bed biomass gasification technologies, points out the existence of gas mixing, the external heat source, catalyst development problems on gas. Finally, it is clear that the gasification of biomass in dual fluidized bed is of great industrial application and development prospect.

  9. Real-time dual-band haptic music player for mobile devices.

    PubMed

    Hwang, Inwook; Lee, Hyeseon; Choi, Seungmoon

    2013-01-01

    We introduce a novel dual-band haptic music player for real-time simultaneous vibrotactile playback with music in mobile devices. Our haptic music player features a new miniature dual-mode actuator that can produce vibrations consisting of two principal frequencies and a real-time vibration generation algorithm that can extract vibration commands from a music file for dual-band playback (bass and treble). The algorithm uses a "haptic equalizer" and provides plausible sound-to-touch modality conversion based on human perceptual data. In addition, we present a user study carried out to evaluate the subjective performance (precision, harmony, fun, and preference) of the haptic music player, in comparison with the current practice of bass-band-only vibrotactile playback via a single-frequency voice-coil actuator. The evaluation results indicated that the new dual-band playback outperforms the bass-only rendering, also providing several insights for further improvements. The developed system and experimental findings have implications for improving the multimedia experience with mobile devices.

  10. Improved atom number with a dual color magneto—optical trap

    NASA Astrophysics Data System (ADS)

    Cao, Qiang; Luo, Xin-Yu; Gao, Kui-Yi; Wang, Xiao-Rui; Chen, Dong-Min; Wang, Ru-Quan

    2012-04-01

    We demonstrate a novel dual color magneto—optical trap (MOT), which uses two sets of overlapping laser beams to cool and trap 87Rb atoms. The volume of cold cloud in the dual color MOT is strongly dependent on the frequency difference of the laser beams and can be significantly larger than that in the normal MOT with single frequency MOT beams. Our experiment shows that the dual color MOT has the same loading rate as the normal MOT, but much longer loading time, leading to threefold increase in the number of trapped atoms. This indicates that the larger number is caused by reduced light induced loss. The dual color MOT is very useful in experiments where both high vacuum level and large atom number are required, such as single chamber quantum memory and Bose—Einstein condensation (BEC) experiments. Compared to the popular dark spontaneous-force optical trap (dark SPOT) technique, our approach is technically simpler and more suitable to low power laser systems.

  11. TU-E-BRB-08: Dual Gated Volumetric Modulated Arc Therapy.

    PubMed

    Wu, J; Fahimian, B; Wu, H; Xing, L

    2012-06-01

    Gated Volumetric Modulated Arc Therapy (VMAT) is an emerging treatment modality for Stereotactic Body Radiotherapy (SBRT). However, gating significantly prolongs treatment time. In order to enhance treatment efficiency, a novel dual gated VMAT, in which dynamic arc deliveries are executed sequentially in alternating exhale and inhale phases, is proposed and evaluated experimentally. The essence of dual gated VMAT is to take advantage of the natural pauses that occur at inspiration and exhalation by alternatively delivering the dose at the two phases, instead of the exhale window only. The arc deliveries at the two phases are realized by rotating gantry forward at the exhale window and backward at the inhale in an alternative fashion. Custom XML scripts were developed in Varian's TrueBeam STx Developer Mode to enable dual gated VMAT delivery. RapidArc plans for a lung case were generated for both inhale and exhale phases. The two plans were then combined into a dual gated arc by interleaving the arc treatment nodes of the two RapidArc plans. The dual gated plan was delivered in the development mode of TrueBeam LINAC onto a motion phantom and the delivery was measured by using pinpoint chamber/film/diode array (delta 4). The measured dose distribution was compared with that computed using Eclipse AAA algorithm. The treatment delivery time was recorded and compared with the corresponding single gated plans. Relative to the corresponding single gated delivery, it was found that treatment time efficiency was improved by 95.5% for the case studied here. Pinpoint chamber absolute dose measurement agreed the calculation to within 0.7%. Diode chamber array measurements revealed that 97.5% of measurement points of dual gated RapidArc delivery passed the 3% and 3mm gamma-test criterion. A dual gated VMAT treatment has been developed and implemented successfully with nearly doubled treatment delivery efficiency. © 2012 American Association of Physicists in Medicine.

  12. Aging Couples in Dual-Career/Earner Families.

    PubMed

    Reeves, Joy B; Darville, Ray L

    1992-01-01

    The authors present results of an empirical study of 611 mature couples in a dual-career or dual-earner famil where at least one spouse is a member of The National Retired Teacher's Association and is retired. We hypothesize that degree of role-sharing will va among mature couples in this special population on the basis of sexcted personal and social characteristics. Through discriminant analysis we identify which personal and social variables best predict whether or not couples currently share roles. We also determine the change in role-sharing over time for these couples. Our hypothesis is confirmed.

  13. Animal Modeling and Neurocircuitry of Dual Diagnosis

    PubMed Central

    Chambers, R. Andrew

    2010-01-01

    Dual diagnosis is a problem of tremendous depth and scope, spanning many classes of mental disorders and addictive drugs. Animal models of psychiatric disorders studied in addiction paradigms suggest a unitary nature of mental illness and addiction vulnerability both on the neurocircuit and clinical-behavioral levels. These models provide platforms for exploring the interactive roles of biological, environmental and developmental factors on neurocircuits commonly involved in psychiatric and addiction diseases. While suggestive of the artifice of segregated research, training, and clinical cultures between psychiatric and addiction fields, this research may lead to more parsimonious, integrative and preventative treatments for dual diagnosis. PMID:20585464

  14. On-chip dual-comb based on quantum cascade laser frequency combs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Villares, G., E-mail: gustavo.villares@phys.ethz.ch; Wolf, J.; Kazakov, D.

    2015-12-21

    Dual-comb spectroscopy is emerging as an appealing application of mid-infrared frequency combs for high-resolution molecular spectroscopy, as it leverages on the unique coherence properties of frequency combs. Here, we present an on-chip dual-comb source based on mid-infrared quantum cascade laser frequency combs. Control of the combs repetition and offset frequencies is obtained by integrating micro-heaters next to each laser. We show that a full control of the dual-comb system is possible, by measuring a multi-heterodyne beating corresponding to an optical bandwidth of 32 cm{sup −1} centered at 1330 cm{sup −1} (7.52 μm), demonstrating that this device represents a critical step towards compact dual-combmore » systems.« less

  15. Dual-Drive Production Prototype Project

    DOT National Transportation Integrated Search

    2009-06-01

    This project was an initiative to engineer, develop and build a plug-in hybrid-electric vehicle using the Dual-Drive system. The project aimed to build a plug-in hybrid utilitarian vehicle on a light commercial vehicle platform. The hybrid vehicle wi...

  16. 42 CFR 411.163 - Coordination of benefits: Dual entitlement situations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Coordination of benefits: Dual entitlement... Health Plans § 411.163 Coordination of benefits: Dual entitlement situations. (a) Basic rule. Coordination of benefits is governed by this section if an individual is eligible for or entitled to Medicare...

  17. 42 CFR 411.163 - Coordination of benefits: Dual entitlement situations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Coordination of benefits: Dual entitlement... Health Plans § 411.163 Coordination of benefits: Dual entitlement situations. (a) Basic rule. Coordination of benefits is governed by this section if an individual is eligible for or entitled to Medicare...

  18. 42 CFR 411.163 - Coordination of benefits: Dual entitlement situations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Coordination of benefits: Dual entitlement... Health Plans § 411.163 Coordination of benefits: Dual entitlement situations. (a) Basic rule. Coordination of benefits is governed by this section if an individual is eligible for or entitled to Medicare...

  19. 42 CFR 411.163 - Coordination of benefits: Dual entitlement situations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Coordination of benefits: Dual entitlement... Health Plans § 411.163 Coordination of benefits: Dual entitlement situations. (a) Basic rule. Coordination of benefits is governed by this section if an individual is eligible for or entitled to Medicare...

  20. 42 CFR 411.163 - Coordination of benefits: Dual entitlement situations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Coordination of benefits: Dual entitlement... Health Plans § 411.163 Coordination of benefits: Dual entitlement situations. (a) Basic rule. Coordination of benefits is governed by this section if an individual is eligible for or entitled to Medicare...

  1. A dual-stage sodium thermal electrochemical converter (Na-TEC)

    NASA Astrophysics Data System (ADS)

    Limia, Alexander; Ha, Jong Min; Kottke, Peter; Gunawan, Andrey; Fedorov, Andrei G.; Lee, Seung Woo; Yee, Shannon K.

    2017-12-01

    The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity through the isothermal expansion of sodium ions. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (650 K-1050 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management. Herein, we demonstrate how the dual-stage device can improve the efficiency by up to 8% points over the best performing single-stage device. We also establish an application regime map for the single- and dual-stage Na-TEC in terms of the power density and the total thermal parasitic loss. Generally, a single-stage Na-TEC should be used for applications requiring high power densities, whereas a dual-stage Na-TEC should be used for applications requiring high efficiency.

  2. Walking Stroop carpet: an innovative dual-task concept for detecting cognitive impairment

    PubMed Central

    Perrochon, A; Kemoun, G; Watelain, E; Berthoz, A

    2013-01-01

    Background Several studies have reported the potential value of the dual-task concept during locomotion in clinical evaluation because cognitive decline is strongly associated with gait abnormalities. However, current dual-task tests appear to be insufficient for early diagnosis of cognitive impairment. Methods Forty-nine subjects (young, old, with or without mild cognitive impairment) underwent cognitive evaluation (Mini-Mental State Examination, Frontal Assessment Battery, five-word test, Stroop, clock-drawing) and single-task locomotor evaluation on an electronic walkway. They were then dual-task-tested on the Walking Stroop carpet, which is an adaptation of the Stroop color–word task for locomotion. A cluster analysis, followed by an analysis of variance, was performed to assess gait parameters. Results Cluster analysis of gait parameters on the Walking Stroop carpet revealed an interaction between cognitive and functional abilities because it made it possible to distinguish dysexecutive cognitive fragility or decline with a sensitivity of 89% and a specificity of 94%. Locomotor abilities differed according to the group and dual-task conditions. Healthy subjects performed less well on dual-tasking under reading conditions than when they were asked to distinguish colors, whereas dysexecutive subjects had worse motor performances when they were required to dual task. Conclusion The Walking Stroop carpet is a dual-task test that enables early detection of cognitive fragility that has not been revealed by traditional neuropsychological tests or single-task walking analysis. PMID:23682211

  3. 3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea.

    PubMed

    Zhao, Mingtao; Kuo, Anthony N; Izatt, Joseph A

    2010-04-26

    Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the effects of patient motion during data acquisition. Procedures are described for correction of image data artifacts resulting from 3D refraction of SDOCT light in the cornea and from non-idealities of the scanning system geometry performed as a pre-requisite for accurate parameter extraction. Zernike polynomial 3D reconstruction and a recursive half searching algorithm (RHSA) were implemented to extract clinical keratometric parameters including anterior and posterior radii of curvature, central cornea optical power, central corneal thickness, and thickness maps of the cornea. Accuracy and repeatability of the extracted parameters obtained using a commercial 859nm SDOCT retinal imaging system with a corneal adapter were assessed using a rigid gas permeable (RGP) contact lens as a phantom target. Extraction of these parameters was performed in vivo in 3 patients and compared to commercial Placido topography and Scheimpflug photography systems. The repeatability of SDOCT central corneal power measured in vivo was 0.18 Diopters, and the difference observed between the systems averaged 0.1 Diopters between SDOCT and Scheimpflug photography, and 0.6 Diopters between SDOCT and Placido topography.

  4. Dual Vector Spaces and Physical Singularities

    NASA Astrophysics Data System (ADS)

    Rowlands, Peter

    Though we often refer to 3-D vector space as constructed from points, there is no mechanism from within its definition for doing this. In particular, space, on its own, cannot accommodate the singularities that we call fundamental particles. This requires a commutative combination of space as we know it with another 3-D vector space, which is dual to the first (in a physical sense). The combination of the two spaces generates a nilpotent quantum mechanics/quantum field theory, which incorporates exact supersymmetry and ultimately removes the anomalies due to self-interaction. Among the many natural consequences of the dual space formalism are half-integral spin for fermions, zitterbewegung, Berry phase and a zero norm Berwald-Moor metric for fermionic states.

  5. State of Training, Clinical Services, and Research on Dual Disorders Across France, India, Israel, and Spain.

    PubMed

    Balhara, Yatan Pal Singh; Lev-Ran, Shaul; Martínez-Raga, José; Benyamina, Amine; Singh, Shalini; Blecha, Lisa; Szerman, Nestor

    2016-01-01

    This article overviews training, clinical services, and research on dual disorders across four countries: France, India, Israel, and Spain. The current dual disorders systems in each of the four countries were reviewed, with a focus on strengths and limitations of each. In France, psychiatric care occurs within the public health care system and involves little training of medical graduates for managing dual disorders. Special courses and forums for specialists have recently started to meet the growing interest of physicians in learning how to manage dual disorders. The Indian health care system grapples with a large treatment gap for mental disorders, and while some treatment services for dual disorders exist, specific research and training efforts on dual disorders are just beginning. Israel has both public- and private sector services for patients with dual disorders, with specialized inpatient and emergency care for the acutely ill as well as day care and therapeutic communities for long-term management. Interest by researchers is growing, but training and education efforts in dual disorders are, however, minimal. Similar to the other countries, addiction and psychiatry disciplines are governed by separate divisions within the National Health System in Spain. There are some dual disorders services available, but they are limited in scope. While medical professionals clearly recognize the importance of dual disorders, there is no such recognition by the national and regional governing bodies. The common thread in various aspects of dual disorder management in each of these four countries is that there is a lower-than-desirable level of attention to dual disorders in terms of care, policy, research, and training. There are growing opportunities for training and continuing education in dual disorders management. We suggest that nations could learn from each other's experiences on how to address the issue of dual disorders.

  6. Temporal lobe epilepsy: analysis of patients with dual pathology.

    PubMed

    Salanova, V; Markand, O; Worth, R

    2004-02-01

    To determine the frequency and types of dual pathology in patients with temporal lobe epilepsy (TLE) and to analyze the clinical manifestations and surgical outcome. A total of 240 patients with TLE underwent temporal resections following a comprehensive pre-surgical evaluation. Thirty-seven (15.4%) of these had hippocampal sclerosis (HS) or temporal lobe gliosis in association with another lesion (dual pathology). Eighteen of 37 patients with dual pathology had heterotopia of the temporal lobe, nine had cortical dysplasia, four had cavernous angiomas or arteriovenous malformations, one had a dysembryoplastic neuroepithelial tumor, one had a contusion and four patients had cerebral infarctions in childhood. 68.5% had abnormal head magnetic resonance imagings, 91.3% had abnormal positron emission tomography scans, and 96% had abnormal ictal SPECT. The intracarotid amobarbital procedure (IAP) showed impaired memory of the epileptogenic side in 72% of the patients. Twenty patients had left and 17 had right-sided en bloc temporal resections, including the lesion and mesial temporal structures. Twenty-six (70.2%) became seizure-free, eight (21.6%) had rare seizures, two (5.4%) had worthwhile seizure reduction and one (2.7%) had no improvement (range of follow-up 1-16 years, mean = 7.4 years). 15.4% had dual pathology. The dual pathology was almost exclusively seen in patients whose lesions were congenital, or occurred early in life, suggesting that the hippocampus is more vulnerable and more readily develops HS in early childhood. Resections, including the lateral and mesial temporal structures led to a favorable outcome with no mortality and little morbidity.

  7. [Dual diagnosis in psychiatric inpatients: prevalence and general characteristics].

    PubMed

    Rodríguez-Jiménez, Roberto; Aragüés, María; Jiménez-Arriero, Miguel Angel; Ponce, Guillermo; Muñoz, Antonio; Bagney, Alexandra; Hoenicka, Janet; Palomo, Tomás

    2008-06-01

    Comorbidity between a substance use disorder (SUD) and another psychiatric disorder is known as dual diagnosis. It is of great relevance due to its important clinical consequences and costs of care. There are practically no published studies on dual diagnosis prevalence in patients admitted to psychiatric hospitalization units in general hospitals (PHUGH) in our country. The objectives were to estimate the prevalence of dual diagnosis in psychiatric inpatients admitted consecutively to a Psychiatric Hospitalization Unit (Hospital Universitario 12 de Octubre, Madrid, Spain) in one year, to compare clinical and sociodemographic variables between the dual diagnosis group (DD group) and the group with a psychiatric disorder but no SUD (PD group), and to study the types of substances used. This is a retrospective study, based on the review of the clinical charts of the 257 patients admitted to this PHUGH in one year. The results showed that, excluding nicotine dependence, 24.9% of our inpatients had a SUD as well as another psychiatric disorder. A statistically significant predominance of men was found in the DD group, as well as a younger age at the time of the study, at the beginning of their psychiatric attention and on their first psychiatric admission, and they had received diagnoses of schizophrenia or related psychoses more often than the PD group, who had mostly affective disorders. The substances most frequently used in the DD group were alcohol (78.1%), cannabis (62.5%), and cocaine (51.6%). Due to the high prevalence and repercussions of dual diagnosis, it would be advisable to have specialized therapeutic programs for its treatment.

  8. Biological Dual-Use Research and Synthetic Biology of Yeast.

    PubMed

    Cirigliano, Angela; Cenciarelli, Orlando; Malizia, Andrea; Bellecci, Carlo; Gaudio, Pasquale; Lioj, Michele; Rinaldi, Teresa

    2017-04-01

    In recent years, the publication of the studies on the transmissibility in mammals of the H5N1 influenza virus and synthetic genomes has triggered heated and concerned debate within the community of scientists on biological dual-use research; these papers have raised the awareness that, in some cases, fundamental research could be directed to harmful experiments, with the purpose of developing a weapon that could be used by a bioterrorist. Here is presented an overview regarding the dual-use concept and its related international agreements which underlines the work of the Australia Group (AG) Export Control Regime. It is hoped that the principles and activities of the AG, that focuses on export control of chemical and biological dual-use materials, will spread and become well known to academic researchers in different countries, as they exchange biological materials (i.e. plasmids, strains, antibodies, nucleic acids) and scientific papers. To this extent, and with the aim of drawing the attention of the scientific community that works with yeast to the so called Dual-Use Research of Concern, this article reports case studies on biological dual-use research and discusses a synthetic biology applied to the yeast Saccharomyces cerevisiae, namely the construction of the first eukaryotic synthetic chromosome of yeast and the use of yeast cells as a factory to produce opiates. Since this organism is considered harmless and is not included in any list of biological agents, yeast researchers should take simple actions in the future to avoid the sharing of strains and advanced technology with suspicious individuals.

  9. Cardiac examination and the effect of dual-processing instruction in a cardiopulmonary simulator.

    PubMed

    Sibbald, Matt; McKinney, James; Cavalcanti, Rodrigo B; Yu, Eric; Wood, David A; Nair, Parvathy; Eva, Kevin W; Hatala, Rose

    2013-08-01

    Use of dual-processing has been widely touted as a strategy to reduce diagnostic error in clinical medicine. However, this strategy has not been tested among medical trainees with complex diagnostic problems. We sought to determine whether dual-processing instruction could reduce diagnostic error across a spectrum of experience with trainees undertaking cardiac physical exam. Three experiments were conducted using a similar design to teach cardiac physical exam using a cardiopulmonary simulator. One experiment was conducted in each of three groups: experienced, intermediate and novice trainees. In all three experiments, participants were randomized to receive undirected or dual-processing verbal instruction during teaching, practice and testing phases. When tested, dual-processing instruction did not change the probability assigned to the correct diagnosis in any of the three experiments. Among intermediates, there was an apparent interaction between the diagnosis tested and the effect of dual-processing instruction. Among relative novices, dual processing instruction may have dampened the harmful effect of a bias away from the correct diagnosis. Further work is needed to define the role of dual-processing instruction to reduce cognitive error. This study suggests that it cannot be blindly applied to complex diagnostic problems such as cardiac physical exam.

  10. The German Dual Apprenticeship System: An Analysis of Its Evolution and Present Challenges.

    ERIC Educational Resources Information Center

    Tremblay, Diane-Gabrielle; Le Bot, Irene

    The evolution of Germany's dual apprenticeship system and the challenges now facing it were reviewed. The following topics were considered: (1) the progression from craft guilds to vocational training; (2) the history of Germany's dual apprenticeship system from its organization in the 1970s; (4) apprenticeship in the dual system; (3) Germany's…

  11. The Wellbeing of Army Personnel in Dual-Military Marriages

    DTIC Science & Technology

    2013-06-01

    experience both negative health and lower subjective feelings of wellbeing . The first year of this study has been focused on research lab development...findings to report. 15. SUBJECT TERMS Dual-Military Marriages, Wellbeing , Health , Work-family Conflict 16. SECURITY CLASSIFICATION OF: 17...However there have been very few studies that have examined the health and wellbeing of individuals in dual-military marital relationships. The

  12. A polynomial primal-dual Dikin-type algorithm for linear programming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jansen, B.; Roos, R.; Terlaky, T.

    1994-12-31

    We present a new primal-dual affine scaling method for linear programming. The search direction is obtained by using Dikin`s original idea: minimize the objective function (which is the duality gap in a primal-dual algorithm) over a suitable ellipsoid. The search direction has no obvious relationship with the directions proposed in the literature so far. It guarantees a significant decrease in the duality gap in each iteration, and at the same time drives the iterates to the central path. The method admits a polynomial complexity bound that is better than the one for Monteiro et al.`s original primal-dual affine scaling method.

  13. Patterns of dual use of snus and cigarettes in a mature snus market.

    PubMed

    Lund, Karl Erik; McNeill, Ann

    2013-03-01

    We examine the prevalence of dual use of snus and cigarettes among Norwegian men by categorizing dual use into four categories according to the frequency of use of each product, considering the order of uptake of both products, and examining reasons for additional snus use. We compare dual users and exclusive cigarette smokers with respect to their smoking intensity, plans for quitting smoking, and future smoking identity. We used a data pool of six cross-sectional, national representative surveys conducted annually in the period 2005-2010 containing a total of 3,524 males aged 16-74. 6.8% of men had some kind of current concomitant use of snus and cigarettes--but only 1% reported a daily consumption of both products. The most typical pattern of dual use was a combination where daily use of one product was paired with occasional use of the other. Dual users consumed significantly fewer cigarettes per week (56.6; n = 226; SD, 53.82) than smokers who had either quit snus (79.6; n = 108; SD, 61.47) or single smokers with no history of snus use (80.2; n = 621; SD, 55.86). Only 24% with a history of dual use reported snus to be their first tobacco product, but the proportion who had initiated tobacco use with snus increased significantly with younger age. Among dual users with daily intake of snus, a majority of 53.6% reported that the purpose of their snus use was to quit smoking. A higher proportion of dual users (74.4%; 95% CI, 68.8-80.0; n = 235) than exclusive smokers (61.3%; 95% CI, 57.6-65.0; n = 658) reported that they most definitely or probably would be totally smoke-free 5 years into the future. In the mature snus market of Norway, the magnitude of dual use of cigarettes and snus is relatively small. Dual users consume fewer cigarettes, and a higher proportion portray themselves as smoke-free in the future than do exclusive cigarette smokers.

  14. Serial Learning Process: Test of Chaining, Position, and Dual-Process Hypotheses

    ERIC Educational Resources Information Center

    Giurintano, S. L.

    1973-01-01

    The chaining, position, and dual-process hypotheses of serial learning (SL) as well as serial recall, reordering, and relearning of paired-associate learning were examined to establish learning patterns. Results provide evidence for dual-process hypothesis. (DS)

  15. The effects of dual tasking on handwriting in patients with Parkinson's disease.

    PubMed

    Broeder, S; Nackaerts, E; Nieuwboer, A; Smits-Engelsman, B C M; Swinnen, S P; Heremans, E

    2014-03-28

    Previous studies have shown that patients with Parkinson's disease (PD) experience extensive problems during dual tasking. Up to now, dual-task interference in PD has mainly been investigated in the context of gait research. However, the simultaneous performance of two different tasks is also a prerequisite to efficiently perform many other tasks in daily life, including upper limb tasks. To address this issue, this study investigated the effect of a secondary cognitive task on the performance of handwriting in patients with PD. Eighteen PD patients and 11 age-matched controls performed a writing task involving the production of repetitive loops under single- and dual-task conditions. The secondary task consisted of counting high and low tones during writing. The writing tests were performed with two amplitudes (0.6 and 1.0cm) using a writing tablet. Results showed that dual-task performance was affected in PD patients versus controls. Dual tasking reduced writing amplitude in PD patients, but not in healthy controls (p=0.046). Patients' writing size was mainly reduced during the small-amplitude condition (small amplitude p=0.017; large amplitude p=0.310). This suggests that the control of writing at small amplitudes requires more compensational brain-processing recourses in PD and is as such less automatic than writing at large amplitudes. In addition, there was a larger dual-task effect on the secondary task in PD patients than controls (p=0.025). The writing tests on the writing tablet proved highly correlated to daily life writing as measured by the 'Systematic Screening of Handwriting Difficulties' test (SOS-test) and other manual dexterity tasks, particularly during dual-task conditions. Taken together, these results provide additional insights into the motor control of handwriting and the effects of dual tasking during upper limb movements in patients with PD. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  16. Dual Enrollment Students' Efficacy Beliefs: An Interpretive Phenomenological Analysis

    ERIC Educational Resources Information Center

    Gronlund, Elizabeth Robin

    2017-01-01

    This interpretive phenomenological analysis explores the lived experience and self-efficacy beliefs of Vermont high school students who participated in a dual enrollment course. Vermont state policy makers have enacted legislation that supports dual enrollment in order to bridge the high school to college transition and create a better educated…

  17. The Dual Participants: A High Risk Drinking Driver Target Group.

    ERIC Educational Resources Information Center

    Kline, Michael V.; And Others

    1988-01-01

    Studied dual participants (N=2,525), multiple offender drinking driver program participants who also attend non-drinking driver alcohol treatment programs. Findings support need for drinking driver programs to be aware of high risk dual participants and for alcohol-related treatment programs to provide drinking and driving education to all dual…

  18. An Evaluation of Instructor Qualifications for Teaching Dual Enrollment Classes

    ERIC Educational Resources Information Center

    Abdul-Karim, Barbara Daaiyah

    2010-01-01

    This study examined instructor qualifications for teaching dual enrollment students, college-level work. This research focused on Maryland dual enrollment programs that offered both high school and college credit to high school students for each college Associate of Arts and Associate of Science transfer course taken. One significant goal of dual…

  19. Dual renin-angiotensin-aldosterone blockade: promises and pitfalls.

    PubMed

    Chrysant, Steven G; Chrysant, George S

    2015-01-01

    Single renin-angiotensin-aldosterone system (RAAS) blockade has been shown to be effective and safe for the treatment of hypertension, coronary heart disease (CHD), heart failure (HF), diabetes, and chronic kidney disease (CKD) with proteinuria. Due to the action of RAAS blockers at various levels of the RAAS cascade, it was hypothesized that dual RAAS blockade would result in more complete inhibition of angiotensin II (Ang II) production and be more effective in blocking its detrimental cardiovascular remodeling effects. Unfortunately, several clinical trials in patients with hypertension, CHD, HF, and CKD with proteinuria have demonstrated no superiority of dual versus single RAAS blockade, but a higher incidence of adverse events. Based on these findings, dual RAAS blockade is no longer recommended for the routine treatment of various cardiovascular diseases, except diabetic nephropathy with proteinuria and HF with reduced ejection fraction. All the new information gathered from studies within the last 3 years will be presented in this review.

  20. CE dual-homing protection in layer 1 VPN

    NASA Astrophysics Data System (ADS)

    Du, Shu; Peng, Yunfeng; Long, Keping

    2008-11-01

    Layer 1 VPN (L1VPN) extends the notion of VPN to the optical domain to provide virtually dedicated circuit like leased lines, so that the security is more enhanced. Despite their secure gains from channel isolation, VPNs still suffer fragilities resulting from link-failures or node-failures. Extensive activities on survivability designs for wavelength-routed optical networks are proposed, including various protection and restoration schemes, but concerns on network edge are rare. Dual-homing is an effective skill to achieve survivability gains for L1VPNs. There are two dual-homing mode: Active/Standby mode and Load-Sharing mode In this paper, we investigate the problem of PE assignment, which is the key of dual-homing design and is NP-hard. We formulate it as an integer programming problem, and propose heuristic solutions. Simulation results show that the proposed solutions work in a correct and effective way and the Load-Sharing mode has higher bandwidth efficiency than Active/Standby mode.