2004-10-01
Gas Chromatographic/Mass Spectrometric Differentiation of Atenolol, Metoprolol , Propranolol, and an Interfering Metabolite Product of Metoprolol ...4. Title and Subtitle 5. Report Date October 2004 Gas Chromatographic/Mass Spectrometric Differentiation of Atenolol, Metoprolol , Propranolol...and an Interfering Metabolite Product of Metoprolol 6. Performing Organization Code 7. Author(s) 8. Performing Organization Report No. Angier MK
NASA Astrophysics Data System (ADS)
Gidaspov, B. V.; Zenkevich, I. G.; Rodin, A. A.
1989-09-01
The problem of identifying halogen-containing organic compounds in their gas-chromatographic and gas-chromatographic-mass-spectrometric (GC-MS) determination in different materials has been examined. Particular attention has been paid not to the complete characterisation of methods for carrying out this analysis but to the most important problem of increasing the selectivity at the stages of sampling, separation, and interpretation of the gas-chromatographic and GC-MS information. The bibliography contains 292 references.
As a first step in a hierarchical scheme to demonstrate the suitability of present U.S. Environmental Protection Agency (USEPA) analysis methods and/or develop new methodology, the gas chromatographic (GC) separation and mass spectrometric (MS) detection characteristics of 328 to...
A combined approach using gas chromatographic retention indices and mass spectrometric characteristics has been elaborated for the isomer-specific identification of the 1700 bromo-, chloro- and bromochloro-dioxins which may be found in the environment. ver 100 dioxins were synthe...
The use of gas chromatographic-mass spectrometric-computer systems in pharmacokinetic studies.
Horning, M G; Nowlin, J; Stafford, M; Lertratanangkoon, K; Sommer, K R; Hill, R M; Stillwell, R N
1975-10-29
Pharmacokinetic studies involving plasma, urine, breast milk, saliva and liver homogenates have been carried out by selective ion detection with a gas chromatographic-mass spectrometric-computer system operated in the chemical ionization mode. Stable isotope labeled drugs were used as internal standards for quantification. The half-lives, the concentration at zero time, the slope (regression coefficient), the maximum velocity of the reaction and the apparent Michaelis constant of the reaction were determined by regression analysis, and also by graphic means.
Discourse for slide presentation: An overview of chemical detection systems
NASA Technical Reports Server (NTRS)
Peters, Randy Alan; Galen, Theodore J.; Pierson, Duane L.
1990-01-01
A brief overview of some of the analytical techniques currently used in monitoring and analyzing permanent gases and selected volatile organic compound in air are presented. Some of the analytical considerations in developing a specific method are discussed. Four broad groups of hardware are discussed: compound class specific personal monitors, gas chromatographic systems, infrared spectroscopic systems, and mass spectrometric residual gas analyzer systems. Three types of detectors are also discussed: catalytic sensor based systems, photoionization detectors, and wet or dry chemical reagent systems. Under gas chromatograph based systems five detector systems used in combination with a GC are covered: thermal conductivity detectors, photoionization detectors, Fourier transform infrared spectrophotometric systems, quadrapole mass spectrometric systems, and a relatively recent development, a surface acoustic wave vapor detector.
Low, I A; Liu, R H; Legendre, M G; Piotrowski, E G; Furner, R L
1986-10-01
A gas chromatograph/quadrupole mass spectrometer system, operated in electron impact/selected ion monitoring mode, is used to determine the intensity ratio of the m/z 59 and the m/z 58 ions of the [C3H8N]+ fragment derived from methamphetamine samples synthesized with varying amounts of 13C-labeled methylamine. Crude products are introduced into the gas chromatograph without prior cleanup. The ratios measured were in excellent agreement with those calculated. A change in 0.25% use of 13C-methylamine is sufficient for product differentiation. The feasibility of using isotope labeling and subsequent mass spectrometric isotope ratio measurement as the basis of a compound tracing mechanism is discussed. Specifically, if methamphetamine samples manufactured from legal sources are asked to incorporate distinct 13C compositions, their sources can be traced when samples are diverted into illegal channels. Samples derived from illicit preparations can also be traced if the manufacturers of a precursor (methylamine in this case) incorporate distinct 13C compositions in their products.
Lipidomics in triacylglycerol and cholesteryl ester oxidation.
Kuksis, Arnis
2007-05-01
Although direct mass spectrometry is capable of identification the major molecular species of lipids in crude total lipid extracts, prior chromatographic isolation is necessary for detection and identification of the minor components. This is especially important for the analysis of the oxolipids, which usually occur in trace amounts in the total lipid extract, and require prior isolation for detailed analysis. Both thin-layer chromatography and adsorption cartridges provide effective means for isolation and enrichment of lipid classes, while gas-liquid chromatography and high performance liquid chromatography with on-line mass spectrometry permit further separation and identification of molecular species. Prior chromatographic resolution is absolutely necessary for the identification of isobaric and chiral molecules, which mass spectrometry/mass spectrometry (MS/MS) cannot distinguish. Both gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry applications may require the preparation of derivatives in order to improve the chromatographic and mass spectrometric properties of the oxolipids which is a small inconvenience for securing analytical reliability. The following chapter reviews the advantages and necessity of combined chromatographic-mass spectrometric approaches to successful identification and quantification of molecular species of oxoacylglycerols and oxocholesteryl esters in in-vitro model studies of lipid peroxidation and in the analyses of oxolipids recovered from tissues.
Analytical techniques for identification and study of organic matter in returned lunar samples
NASA Technical Reports Server (NTRS)
Burlingame, A. L.
1974-01-01
The results of geochemical research are reviewed. Emphasis is placed on the contribution of mass spectrometric data to the solution of specific structural problems. Information on the mass spectrometric behavior of compounds of geochemical interest is reviewed and currently available techniques of particular importance to geochemistry, such as gas chromatograph-mass spectrometer coupling, modern sample introduction methods, and computer application in high resolution mass spectrometry, receive particular attention.
Kawata, K; Ibaraki, T; Tanabe, A; Yagoh, H; Shinoda, A; Suzuki, H; Yasuhara, A
2001-03-09
Simple gas chromatographic-mass spectrometric determination of hydrophilic organic compounds in environmental water was developed. A cartridge containing activated carbon fiber felt was made by way of trial and was evaluated for solid-phase extraction of the compounds in water. The hydrophilic compounds investigated were acrylamide, N,N-dimethylacetamide, N,N-dimethylformamide, 1,4-dioxane, furfural, furfuryl alcohol, N-nitrosodiethylamine and N-nitrosodimethylamine. Overall recoveries were good (80-100%) from groundwater and river water. The relative standard deviations ranged from 4.5 to 16% for the target compounds. The minimum detectable concentrations were 0.02 to 0.03 microg/l. This method was successfully applied to several river water samples.
Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff
2015-11-01
Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Eganhouse, R.P.; Dorsey, T.F.; Phinney, C.S.; Westcott, A.M.
1993-01-01
A method is described for the determination of the C6-C10 aromatic hydrocarbons in water based on purge-and-trap capillary gas chromatography with flame ionization and mass spectrometric detection. Retention time data and 70 eV mass spectra were obtained for benzene and all 35 C7-C10 aromatic hydrocarbons. With optimized chromatographic conditions and mass spectrometric detection, benzene and 33 of the 35 alkylbenzenes can be identified and measured in a 45-min run. Use of a flame ionization detector permits the simultaneous determination of benzene and 26 alkylbenzenes.
The 209 polychlorinated biphenyl (PCB) congeners and associated nine isomeric groups (nine groups of PCBs with the same degree of chlorination) have been long recorded as high endocrine disrupting chemicals in the environment. Difficult analytical problems exist, in those frequen...
NASA Technical Reports Server (NTRS)
Mahaffy, Paul
2012-01-01
The Sample Analysis at Mars (SAM) suite of instruments on the Curiosity Rover of Mars Science Laboratory Mission is designed to provide chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples. The goals of the science investigation enabled by the gas chromatograph mass spectrometer and tunable laser spectrometer instruments of SAM are to work together with the other MSL investigations is to quantitatively assess habitability through a series of chemical and geological measurements. We describe the multi-column gas chromatograph system employed on SAM and the approach to extraction and analysis of organic compounds that might be preserved in ancient martian rocks.
A SURVEY OF INDOOR AIR CONTAMINATES USING SEMIPERMEABLE MEMBRANE DEVICES
Semipermeable membrane devices (SPMDs) were deployed in indoor areas in approximately 50 residences along the border between Arizona and Mexico to measure airborne contaminants. The results of the primary analyses and gas chromatographic/mass spectrometric confirmation for org...
NASA Technical Reports Server (NTRS)
Abell, P. I.; Cadogan, P. H.; Eglinton, G.; Maxwell, J. R.; Pillinger, C. T.
1971-01-01
Indigenous gases and hydrolyzable carbon compounds in Apollo 11 and 12 samples through gas chromatographic and mass spectrometric examination, noting meteoritic impact and solar wind implantation as probable origins
NONINVASIVE APPROACHES FOR TOXICOLOICAL RESEARCH OF THE LUNG
Four presentations are planned to overview this topic: 1) a review of gas chromatographic and mass spectrometric methods and sensitivity of these measures of volatile molecules present in exhaled breath. Molecular species present in breath have been predictive markers in a number...
NASA Technical Reports Server (NTRS)
Biemann, K.
1973-01-01
Data processing techniques were developed to measure with high precision and sensitivity the line spectra produced by a high resolution mass spectrometer. The most important aspect of this phase was the interfacing of a modified precision microphotometer-comparator with a computer and the improvement of existing software to serve the special needs of the investigation of lunar samples. In addition, a gas-chromatograph mass spectrometer system was interfaced with the same computer to allow continuous recording of mass spectra on a gas chromatographic effluent and efficient evaluation of the resulting data. These techniques were then used to detect and identify organic compounds present in the samples returned by the Apollo 11 and 12 missions.
NASA Technical Reports Server (NTRS)
Haug, P.; Schnoes, H. K.; Burlingame, A. L.
1971-01-01
Study of solvent extractable acidic constituents of oil shale from the Colorado Green River Formation. Identification of individual components is based on gas chromatographic and mass spectrometric data obtained for their respective methyl esters. Normal acids, isoprenoidal acids, alpha, omega-dicarboxylic acids, mono-alpha-methyl dicarboxylic acids and methyl ketoacids were identified. In addition, the presence of monocyclic, benzoic, phenylalkanoic and naphthyl-carboxylic acids, as well as cycloaromatic acids, is demonstrated by partial identification.
Roussis; Fitzgerald
2000-04-01
The coupling of gas chromatographic simulated distillation with mass spectrometry for the determination of the distillation profiles of crude oils is reported. The method provides the boiling point distributions of both weight and volume percent amounts. The weight percent distribution is obtained from the measured total ion current signal. The total ion current signal is converted to weight percent amount by calibration with a reference crude oil of a known distillation profile. Knowledge of the chemical composition of the crude oil across the boiling range permits the determination of the volume percent distribution. The long-term repeatability is equivalent to or better than the short-term repeatability of the currently available American Society for Testing and Materials (ASTM) gas chromatographic method for simulated distillation. Results obtained by the mass spectrometric method are in very good agreement with results obtained by conventional methods of physical distillation. The compositional information supplied by the method can be used to extensively characterize crude oils.
A thermospray-liquid chromatographic/mass spectrometric (TS-LC/MS) method was evaluated in an interlaboratory study for determining 3 N-methyl carbamates (bendiocarb, carbaryl, and carbofuran), 3-N-methyl carbamoyloximes (aldicarb, methomyl, and oxamyl), 2 substituted urea pestic...
Advanced Global Atmospheric Gases Experiment (AGAGE)
NASA Technical Reports Server (NTRS)
Prinn, Ronald G.
2001-01-01
AGAGE comprises continuous high frequency in-situ gas chromatographic FID/ECD measurements of two biogenic/anthropogenic gases (CH4, N2O) and five anthropogenic gases (CFCl3, CF2Cl2, CH3CCl3, CF2ClCFCl2, CCl4) which are carried out at five globally distributed sites (Ireland, California, Barbados, Samoa, Tasmania). Also, high frequency in-situ gas-chromatographic mass spectrometric measurements of about 30 species including chlorofluorocarbon replacements and many natural halocarbons are made at two sites (Ireland, Tasmania), and will soon begin at the other three sites. Finally, high frequency in-situ gas chromatographic HgO-RD measurements of CO and H2 are performed at two sites (Ireland, Tasmania). The goal is quantitative determination of the sources, sinks, and circulation of these environmentally important gases.
Revelsky, A I; Samokhin, A S; Virus, E D; Rodchenkov, G M; Revelsky, I A
2011-04-01
The method of high sensitive gas chromatographic/time-of-flight mass-spectrometric (GC/TOF-MS) analysis of steroids was developed. Low-resolution TOF-MS instrument (with fast spectral acquisition rate) was used. This method is based on the formation of the silyl derivatives of steroids; exchange of the reagent mixture (pyridine and N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA)) for tert-butylmethylether; offline large sample volume injection of this solution based on sorption concentration of the respective derivatives from the vapour-gas mixture flow formed from the solution and inert gas flows; and entire analytes solvent-free concentrate transfer into the injector of the gas chromatograph. Detection limits for 100 µl sample solution volume were 0.5-2 pg/µl (depending on the component). Application of TOF-MS model 'TruTOF' (Leco, St Joseph, MO, USA) coupled with gas chromatograph and ChromaTOF software (Leco, St Joseph, MO, USA) allowed extraction of the full mass spectra and resolving coeluted peaks. Due to use of the proposed method (10 µl sample aliquot) and GC/TOF-MS, two times more steroid-like compounds were registered in the urine extract in comparison with the injection of 1 µl of the same sample solution. Copyright © 2010 John Wiley & Sons, Ltd.
Tiscione, Nicholas B; Yeatman, Dustin Tate; Shan, Xiaoqin; Kahl, Joseph H
2013-10-01
Volatiles are frequently abused as inhalants. The methods used for identification are generally nonspecific if analyzed concurrently with ethanol or require an additional analytical procedure that employs mass spectrometry. A previously published technique utilizing a capillary flow technology splitter to simultaneously quantitate and confirm ethyl alcohol by flame ionization and mass spectrometric detection after headspace sampling and gas chromatographic separation was evaluated for the detection of inhalants. Methanol, isopropanol, acetone, acetaldehyde, toluene, methyl ethyl ketone, isoamyl alcohol, isobutyl alcohol, n-butyl alcohol, 1,1-difluoroethane, 1,1,1-trifluoroethane, 1,1,1,2-tetrafluoroethane (Norflurane, HFC-134a), chloroethane, trichlorofluoromethane (Freon®-11), dichlorodifluoromethane (Freon®-12), dichlorofluoromethane (Freon®-21), chlorodifluoromethane (Freon®-22) and 1,2-dichlorotetrafluoroethane (Freon®-114) were validated for qualitative identification by this method. The validation for qualitative identification included evaluation of matrix effects, sensitivity, carryover, specificity, repeatability and ruggedness/robustness.
The ALE/GAGE/AGAGE Network (DB1001)
Prinn, Ronald G. [MIT, Center for Global Change Science; Weiss, Ray F. [University of California, San Diego; Scripps Institution of Oceanography; Krummel, Paul B. [CSIRO Oceans and Atmosphere, Cape Grim; O'Doherty, Simon [University of Bristol, Barbados and Mace Head Stations; Fraser, Paul [CSIRO Oceans and Atmosphere; Muhle, Jens [UCSD Scripps Institution of Oceanography; Cape Matatula Station; Reimann, Stefan [Swiss Federal Laboratories for Materials Science and Research (EMPA); Jungfraujoch Station; Vollmer, Martin [Swiss Federal Laboratories for Materials Science and Research (EMPA); Jungfraujoch Station; Simmonds, Peter G. [University of Bristol, Atmospheric Chemistry Research Group; Mace Head Station; Malone, Michela [University of Urbino; Monte Cimone Station; Arduini, Jgor [University of Urbino; Monte Cimone Station; Lunder, Chris [Norwegian Institute for Air Research; Ny Alesund Station; Hermansen, Ove [Norwegian Inst. for Air Research (NILU), Kjeller (Norway); Ny Alesund Station; Schmidbauer, Norbert [Norwegian Inst. for Air Research (NILU), Kjeller (Norway); Global Network; Young, Dickon [University of Bristol; Ragged Point Station; Wang, Hsiang J. (Ray) [Geogia Institute of Technology, School of Earth and Atmospheric Sciences; Global Network; Huang, Jin; Rigby, Matthew [University of Bristol; Global Network; Harth, Chris [UCSD, Scripps Institutioon of Oceanography; Global Network; Salameh, Peter [UCSD, Scripps Institution of Oceanography; Global Network; Spain, Gerard [National University of Ireland; Global Network; Steele, Paul [CSIRO Oceans and Atmosphere; Global Network; Arnold, Tim; Kim, Jooil [UCSD, Scripps Institution of Oceanography; Global Network; Derek, Nada; mitrevski, Blagoj; Langenfelds, Ray
2008-01-01
In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. More information may be found at the AGAGE home page: http://agage.eas.gatech.edu/instruments-gcms-medusa.htm.
Mass spectrometry. [in organic chemistry
NASA Technical Reports Server (NTRS)
Burlingame, A. L.; Shackleton, C. H. L.; Howe, I.; Chizhov, O. S.
1978-01-01
A review of mass spectrometry in organic chemistry is given, dealing with advances in instrumentation and computer techniques, selected topics in gas-phase ion chemistry, and applications in such fields as biomedicine, natural-product studies, and environmental pollution analysis. Innovative techniques and instrumentation are discussed, along with chromatographic-mass spectrometric on-line computer techniques, mass spectral interpretation and management techniques, and such topics in gas-phase ion chemistry as electron-impact ionization and decomposition, photoionization, field ionization and desorption, high-pressure mass spectrometry, ion cyclotron resonance, and isomerization reactions of organic ions. Applications of mass spectrometry are examined with respect to bio-oligomers and their constituents, biomedically important substances, microbiology, environmental organic analysis, and organic geochemistry.
A practical and sensitive method to assess volatile organic compounds (VOCs) from JP-8 jet fuel in human whole blood was developed by modifying previously established liquid-liquid extraction procedures, optimizing extraction times, solvent volume, specific sample processing te...
Storage and retrieval of mass spectral information
NASA Technical Reports Server (NTRS)
Hohn, M. E.; Humberston, M. J.; Eglinton, G.
1977-01-01
Computer handling of mass spectra serves two main purposes: the interpretation of the occasional, problematic mass spectrum, and the identification of the large number of spectra generated in the gas-chromatographic-mass spectrometric (GC-MS) analysis of complex natural and synthetic mixtures. Methods available fall into the three categories of library search, artificial intelligence, and learning machine. Optional procedures for coding, abbreviating and filtering a library of spectra minimize time and storage requirements. Newer techniques make increasing use of probability and information theory in accessing files of mass spectral information.
Slabizki, Petra; Legrum, Charlotte; Meusinger, Reinhard; Schmarr, Hans-Georg
2014-10-01
The three constitutional isomers of dimethyl-substituted methoxypyrazines: 3,5-dimethyl-2-methoxypyrazine 1; 2,5-dimethyl-3-methoxypyrazine 2; and 2,3-dimethyl-5-methoxypyrazine 3 are potent flavor compounds with similar mass spectrometric, gas chromatographic, and nuclear magnetic resonance spectroscopic behavior. Therefore, unambiguous analytical determination is critical, particularly in complex matrices. The unequivocal identification of 1-3 could be achieved by homo- and heteronuclear NMR correlation experiments. The observed mass fragmentation for 1-3 is proposed and discussed, benefitting from synthesized partially deuterated 1 and 2. On common polar and apolar stationary phases used in gas chromatography (GC) 1 and 2 show similar behavior whereas 3 can be separated. In our focus on off-flavor analysis with respect to wine aroma, 1 has been described as a "moldy" off-flavor compound in cork and 2 as a constituent in Harmonia axyridis contributing to the so-called "ladybug taint," whereas 3 has not yet been described as a constituent of wine aroma. A successful separation of 1 and 2 could be achieved on octakis-(2,3-di-O-pentyl-6-O-methyl)-γ-cyclodextrin as stationary phase in GC. Applying heart-cut multidimensional GC analysis with tandem mass spectrometric detection we could confirm the presence of 1 as a "moldy" off-flavor compound in cork. However, in the case of Harmonia axyridis, a previous identification of 2 has to be reconsidered. In our experiments we identified the constitutional isomer 1, which was also found in Coccinella septempunctata, another species discussed with respect to the "ladybug taint." The analysis of such structurally related compounds is a demonstrative example for the importance of a chromatographic separation, as mass spectrometric data by itself could not guarantee the unequivocal identification.
Kailasa, Suresh Kumar; Wu, Hui-Fen
2013-07-01
Recently, mass spectrometric related techniques have been widely applied for the identification and quantification of neurochemicals and their metabolites in biofluids. This article presents an overview of mass spectrometric techniques applied in the detection of neurological substances and their metabolites from biological samples. In addition, the advances of chromatographic methods (LC, GC and CE) coupled with mass spectrometric techniques for analysis of neurochemicals in pharmaceutical and biological samples are also discussed.
Loconto, Paul R; Isenga, David; O'Keefe, Michael; Knottnerus, Mark
2008-01-01
Polybrominated diphenyl ethers (PBDEs) are isolated and recovered with acceptable percent recoveries from human serum via liquid-liquid extraction and column chromatographic cleanup and fractionation with quantitation using capillary gas chromatography-mass spectrometry with electron capture negative ion and selected ion monitoring. PBDEs are found in unspiked serum. An alternative sample preparation approach is developed using sheep serum that utilizes a formic acid pre-treatment followed by reversed-phase solid-phase disk extraction and normal-phase solid-phase cleanup using acidified silica gel that yields>50% recoveries. When these percent recoveries are combined with a minimized phase ratio for human serum and very low instrument detection limits, method detection limits below 500 parts-per-trillion are realized.
Oxotremorine does not enhance acetylcholine release from rat diaphragm preparations.
Gundersen, C. B.; Jenden, D. J.
1980-01-01
We have reinvestigated the dramatic effect of oxotremorine on acetylcholine release from the rat diaphragm reported by Das, Ganguly & Vedasiromoni (1978), using a rigorous gas chromatographic mass spectrometric/isotope dilution method for identification and measurement of acetylcholine and choline. Oxotremorine (10 microM) causes no significant change in the spontaneous or evoked (1 or 10 Hz) release or in the tissue levels of acetylcholine or choline. PMID:7426831
USDA-ARS?s Scientific Manuscript database
High performance liquid chromatography (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were tested for their potential in differentiating organic and conventional peppermint samples. Ten organic and ten conventional peppermint samples were examined using HPLC-UV and FI...
Structure elucidation of metabolite x17299 by interpretation of mass spectrometric data.
Zhang, Qibo; Ford, Lisa A; Evans, Anne M; Toal, Douglas R
2017-01-01
A major bottleneck in metabolomic studies is metabolite identification from accurate mass spectrometric data. Metabolite x17299 was identified in plasma as an unknown in a metabolomic study using a compound-centric approach where the associated ion features of the compound were used to determine the true molecular mass. The aim of this work is to elucidate the chemical structure of x17299, a new compound by de novo interpretation of mass spectrometric data. An Orbitrap Elite mass spectrometer was used for acquisition of mass spectra up to MS 4 at high resolution. Synthetic standards of N,N,N -trimethyl-l-alanyl-l-proline betaine (l,l-TMAP), a diastereomer, and an enantiomer were chemically prepared. The planar structure of x17299 was successfully proposed by de novo mechanistic interpretation of mass spectrometric data without any laborious purification and nuclear magnetic resonance spectroscopic analysis. The proposed structure was verified by deuterium exchanged mass spectrometric analysis and confirmed by comparison to a synthetic standard. Relative configuration of x17299 was determined by direct chromatographic comparison to a pair of synthetic diastereomers. Absolute configuration was assigned after derivatization of x17299 with a chiral auxiliary group followed by its chromatographic comparison to a pair of synthetic standards. The chemical structure of metabolite x17299 was determined to be l,l-TMAP.
2010-01-01
Chrom LC –MS...Literature 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE A liquid chromatographic–mass spectrometric ( LC –MS) method for the analysis of the 5a...Journal of Chromatography B journa l homepage: www.e lsev ier .com/ locate /chromb A liquid chromatographic–mass spectrometric ( LC –MS) method for
Dudley, E; El-Shakawi, S; Games, D E; Newton, R P
2000-03-01
A chromatographic separation of nucleosides from urine has been developed in order to facilitate their mass spectrometric analysis for clinical diagnosis. A number of chromatographic resins were studied in order to develop an effective and efficient purification procedure. The optimized sequential protocol comprises a centrifugation, acidification and neutralization step, followed by application of an affinity chromatographic column and finally further separation on an acidic cation exchange column and a basic anion exchanger. This scheme shows effective clean-up of a standard radiolabelled nucleoside with a recovery of 92.5%, and recovery of nucleosides added to urine samples before extraction showed recoveries of 72-82%.
Measurement techniques for trace metals in coal-plant effluents: A brief review
NASA Technical Reports Server (NTRS)
Singh, J. J.
1979-01-01
The strong features and limitations of techniques for determining trace elements in aerosols emitted from coal plants are discussed. Techniques reviewed include atomic absorption spectroscopy, charged particle scattering and activation, instrumental neutron activation analysis, gas/liquid chromatography, gas chromatographic/mass spectrometric methods, X-ray fluorescence, and charged-particle-induced X-ray emission. The latter two methods are emphasized. They provide simultaneous, sensitive multielement analyses and lend themselves readily to depth profiling. It is recommended that whenever feasible, two or more complementary techniques should be used for analyzing environmental samples.
Development of gas chromatographic methods for the analyses of organic carbonate-based electrolytes
NASA Astrophysics Data System (ADS)
Terborg, Lydia; Weber, Sascha; Passerini, Stefano; Winter, Martin; Karst, Uwe; Nowak, Sascha
2014-01-01
In this work, novel methods based on gas chromatography (GC) for the investigation of common organic carbonate-based electrolyte systems are presented, which are used in lithium ion batteries. The methods were developed for flame ionization detection (FID), mass spectrometric detection (MS). Further, headspace (HS) sampling for the investigation of solid samples like electrodes is reported. Limits of detection are reported for FID. Finally, the developed methods were applied to the electrolyte system of commercially available lithium ion batteries as well as on in-house assembled cells.
[Gas chromatographic/mass spectrometric analysis of boldenone urinary metabolites in man].
Zhang, J; Liu, C S; Zhou, T H
1991-01-01
The metabolism of boldenone (17 beta-hydroxy-1,4-androstem-3-one) in man has been investigated by gas chromatography/mass spectrometry. After oral administration of a 20 mg dose to man, six metabolites were detected in the conjugated fraction of the urinary samples. Boldenone, the major compound excreted in urine, was detected within 34 h after administration. In addition, several metabolites, resulting from the hydroxylation of boldenone and the reduction of the unsaturated carbon bonds of boldenone, were detected in the urine samples varying from 9 to 83 h. Extraction and fractionation of these metabolites were achieved by using XAD-2 column and gas chromatography. The recovery of the whole procedure was studied. Furthermore, the mass spectra of the metabolites are presented and major fragment pathways are discussed.
Kasuya, F; Igarashi, K; Fukui, M
1987-05-01
We describe a gas-liquid chromatographic (GC) method for determination of oxybuprocaine, and a gas chromatographic-mass spectrometric (GC-MS) method for simultaneous determination of four of its nine metabolites in urine. We used an Extrelut column to simply and rapidly extract oxybuprocaine and its metabolites from urine. For the GC-MS analyses, we monitored the characteristic fragment ions at m/z 353, 395, 369, 411, and 235 for 3-butoxy-4-aminobenzoic acid (metabolite 2, M-2), 3-butoxy-4-acetylaminobenzoic acid (M-3), 3-hydroxy-4-aminobenzoic acid (M-4), 3-hydroxy-4-acetylaminobenzoic acid (M-5), and methaqualone (internal standard), respectively. We quantified the glucuronide of M-2 after enzymic treatment. The assay's selectivity and reproducibility (within-day and between-day CVs less than 8% for all metabolites) make it applicable to determine oxybuprocaine and its metabolites in human urine. Mean 9-h urinary excretion of oxybuprocaine and its five metabolites from four healthy volunteers was 89.2% after a 100-mg oral dose.
1987-01-01
due to interferences in the pollen. However, the identity of the interferents is presently unknown. A dried papaya leaf was treated with 10 ml of warm...Known amounts of DON, DAS, and T-2 were spiked on a blank (trichothecene-free) papaya leaf and left exposed in a bottle for 1 year. At the end of the year...Simple Trichothecenes from Leaf Sample after Prolonged Exposure ............... 35 12 Sample Analysis .............................. .... 37 6 MASS
Bromate is a disinfection by-product in drinking water, formed during the ozonation of source water containing bromide. An inductively coupled plasma mass spectrometer is combined with an ion chromatograph for the analysis of bromate in drinking waters. Three chromatographic colu...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beck, B.
1973-01-01
From international colloquium: the identification of irradiated foodstuffs; Karlsrahe, Germany (24 Oct 1973). Tripalmitate, tristearate, trioleate, oleic acid methyl ester, linoleic acid methyl ester, lauric acid, lard, coconut butter, sunflower oil, and olive oil were irradiated at 0.5-6 Mrad,or heated up to 174 deg C for 24 hr. The fission products were fractionally distilled with silica gel according to polarity into elutropic series. Subsequent identification and quantitative determination were done by gas chromatography and mass spectrometry. Approximately 28 hydrocarbons and 24 oxygen compounds are dealt with, the typical substances being described individually as regards their identification and quantitative distribution. (GE)
Sandra, Koen; Vandenheede, Isabel; Sandra, Pat
2014-03-28
Protein biopharmaceuticals such as monoclonal antibodies and therapeutic proteins are currently in widespread use for the treatment of various life-threatening diseases including cancer, autoimmune disorders, diabetes and anemia. The complexity of protein therapeutics is far exceeding that of small molecule drugs; hence, unraveling this complexity represents an analytical challenge. The current review provides the reader with state-of-the-art chromatographic and mass spectrometric tools available to dissect primary and higher order structures, post-translational modifications, purity and impurity profiles and pharmacokinetic properties of protein therapeutics. Copyright © 2013 Elsevier B.V. All rights reserved.
Investigation of the volatile species in the lunar soil
NASA Astrophysics Data System (ADS)
Wurz, Peter; Hofer, Lukas; Tulej, Marek; Lasi, Davide; Cabane, Michel; Cosica, David; Gerasimov, Mikhail; Rodinov, Daniel
2013-04-01
Two spacecraft, Luna-Glob and Luna-Resource of Roskosmos (Russia), will be landing on the lunar south pole in 2016 and 2018, respectively. These spacecraft will carry a complex scientific payload. Part of the scientific instrumentation is the gas-chromatographic mass-spectrometric complex, which combines a Thermal Differential Analyser (TDA), a Gas Chromatograph (GC), and a mass spectrometer (MS). This instrument is dedicated to the investigation of the volatiles in the lunar soil, its chemical composition, the fraction of water and organic species, and the identification of noble gases. Measurement of isotopic composition will be performed of CHON elements (13C/12C, D/H, 17O/16O, 18O/16O, 15N/14N) and noble gases. We developed a prototype GC-MS instrument for these missions where the GC part is heritage from the Phobos Grunt mission of Roskosmos and the MS part is a complete new development for the Luna missions. We have carried out several GC-MS measurements on calibration gas mixtures that demonstrate that this instrument fulfills the scientific requirements for the Luna missions.
NASA Technical Reports Server (NTRS)
Lamontagne, R. A.; Swinnerton, J. W.; Wilkniss, P. E.; Bressan, D. J.; Lebel, P. J.; Goldstein, H. W.
1976-01-01
The meteorological conditions during this program consisted of a stagnant high pressure system which was subsequently replaced by southward moving Canadian air. This change in air masses produced distinct changes in the ambient CO concentrations. Ground level concentrations decreased from an average of 1.3 ppm at the beginning of the experiment to 0.2 ppm at the end. Vertical profiles obtained during the experiment showed decreases in the CO concentrations with altitude. Agreement of gas chromatography data for CO and CH4 by NASA and NRL was within 5% for the concentrations encountered. Results from NASA's Infrared Fourier Spectrometer agreed with the gas chromatographic results both in trends and concentrations of CO and CH4 observed with the passing frontal system.
Li, Guo-Sheng; Wei, Xian-Yong
2017-01-01
Elucidation of chemical composition of biooil is essentially important to evaluate the process of lignocellulosic biomass (LCBM) conversion and its upgrading and suggest proper value-added utilization like producing fuel and feedstock for fine chemicals. Although the main components of LCBM are cellulose, hemicelluloses, and lignin, the chemicals derived from LCBM differ significantly due to the various feedstock and methods used for the decomposition. Biooil, produced from pyrolysis of LCBM, contains hundreds of organic chemicals with various classes. This review covers the methodologies used for the componential analysis of biooil, including pretreatments and instrumental analysis techniques. The use of chromatographic and spectrometric methods was highlighted, covering the conventional techniques such as gas chromatography, high performance liquid chromatography, Fourier transform infrared spectroscopy, nuclear magnetic resonance, and mass spectrometry. The combination of preseparation methods and instrumental technologies is a robust pathway for the detailed componential characterization of biooil. The organic species in biooils can be classified into alkanes, alkenes, alkynes, benzene-ring containing hydrocarbons, ethers, alcohols, phenols, aldehydes, ketones, esters, carboxylic acids, and other heteroatomic organic compounds. The recent development of high resolution mass spectrometry and multidimensional hyphenated chromatographic and spectrometric techniques has considerably elucidated the composition of biooils. PMID:29387086
Becker, M; Zweckmair, T; Forneck, A; Rosenau, T; Potthast, A; Liebner, F
2013-03-15
Gas chromatographic analysis of complex carbohydrate mixtures requires highly effective and reliable derivatisation strategies for successful separation, identification, and quantitation of all constituents. Different single-step (per-trimethylsilylation, isopropylidenation) and two-step approaches (ethoximation-trimethylsilylation, ethoximation-trifluoroacetylation, benzoximation-trimethylsilylation, benzoximation-trifluoroacetylation) have been comprehensively studied with regard to chromatographic characteristics, informational value of mass spectra, ease of peak assignment, robustness toward matrix effects, and quantitation using a set of reference compounds that comprise eight monosaccharides (C(5)-C(6)), glycolaldehyde, and dihydroxyacetone. It has been shown that isopropylidenation and the two oximation-trifluoroacetylation approaches are least suitable for complex carbohydrate matrices. Whereas the former is limited to compounds that contain vicinal dihydroxy moieties in cis configuration, the latter two methods are sensitive to traces of trifluoroacetic acid which strongly supports decomposition of ketohexoses. It has been demonstrated for two "real" carbohydrate-rich matrices of biological and synthetic origin, respectively, that two-step ethoximation-trimethylsilylation is superior to other approaches due to the low number of peaks obtained per carbohydrate, good peak separation performance, structural information of mass spectra, low limits of detection and quantitation, minor relative standard deviations, and low sensitivity toward matrix effects. Copyright © 2013 Elsevier B.V. All rights reserved.
Schubert, Birthe; Oberacher, Herbert
2011-06-03
In this study the impact of solvent conditions on the performance of μLC/MS for the analysis of basic drugs was investigated. Our aim was to find experimental conditions that enable high-performance chromatographic separation particularly at overloading conditions paired with a minimal loss of mass spectrometric detection sensitivity. A focus was put on the evaluation of the usability of different kinds of acidic modifiers (acetic acid (HOAc), formic acid (FA), methansulfonic acid (CH₃SO₃H), trifluoroacetic acid (TFA), pentafluoropropionic acid (PFPA), and heptafluorobutyric acid (HFBA)). The test mixture consisted of eleven compounds (bunitrolol, caffeine, cocaine, codeine, diazepam, doxepin, haloperidol, 3,4-methylendioxyamphetamine, morphine, nicotine, and zolpidem). Best chromatographic performance was obtained with the perfluorinated acids. Particularly, 0.010-0.050% HFBA (v/v) was found to represent a good compromise in terms of chromatographic performance and mass spectrometric detection sensitivity. Compared to HOAc, on average a 50% reduction of the peak widths was observed. The use of HFBA was particularly advantageous for polar compounds such as nicotine; only with such a hydrophobic ion-pairing reagent chromatographic retention of nicotine was observed. Best mass spectrometric performance was obtained with HOAc and FA. Loss of detection sensitivity induced by HFBA, however, was moderate and ranged from 0 to 40%, which clearly demonstrates that improved chromatographic performance is able to compensate to a large extent the negative effect of reduced ionization efficiency on detection sensitivity. Applications of μLC/MS for the qualitative and quantitative analysis of clinical and forensic toxicological samples are presented. Copyright © 2011 Elsevier B.V. All rights reserved.
Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E
2008-05-23
Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.
La Barbera, Giorgia; Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo
2017-03-01
The aim of metabolic untargeted profiling is to detect and identify unknown compounds in a biological matrix to achieve the most comprehensive metabolic coverage. In phytochemical mixtures, however, the complexity of the sample could present significant difficulties in compound identification. In this case, the optimization of both the chromatographic and the mass-spectrometric conditions is supposed to be crucial for the detection and identification of the largest number of compounds. In this work, a systematic investigation of different chromatographic and mass-spectrometric conditions is presented to achieve a comprehensive untargeted profiling of a strawberry extract (Fragaria × ananassa). To fulfill this aim, an ultra-high-pressure liquid chromatography system coupled via an electrospray source to a hybrid quadrupole-Orbitrap mass spectrometer was used. Spectra were acquired in data-dependent mode, and several parameters were investigated to acquire the largest possible number of both mass spectrometry (MS) features and MS 2 mass spectra for unique metabolites. The main classes of polyphenols studied were flavonoids, phenolic acids, dihydrochalcones, ellagitannins, and proanthocyanidins. Method optimization allowed to us identify and tentatively identify 18 and 113 compounds, respectively, among which 74 have never been reported before in strawberries and, to the best of our knowledge, 22 of them have never been reported before. The results show the importance of an extended investigation of the chromatographic and mass-spectrometric method before a complete untargeted profiling of complex phytochemical mixtures.
Lindley, C.E.; Stewart, J.T.; Sandstrom, M.W.
1996-01-01
A sensitive and reliable gas chromatographic/mass spectrometric (GC/MS) method for determining acetochlor in environmental water samples was developed. The method involves automated extraction of the herbicide from a filtered 1 L water sample through a C18 solid-phase extraction column, elution from the column with hexane-isopropyl alcohol (3 + 1), and concentration of the extract with nitrogen gas. The herbicide is quantitated by capillary/column GC/MS with selected-ion monitoring of 3 characteristic ions. The single-operator method detection limit for reagent water samples is 0.0015 ??g/L. Mean recoveries ranged from about 92 to 115% for 3 water matrixes fortified at 0.05 and 0.5 ??g/L. Average single-operator precision, over the course of 1 week, was better than 5%.
Schmarr, Hans-Georg; Wacker, Michael; Mathes, Maximilian
2017-01-20
An isotopic separation of acetaldehyde and acetaldehyde-2,2,2-d3 was achieved in a temperature programmed run on a porous layer open tubular (PLOT) capillary column coated with particles of divinylbenzene ethylene glycol/dimethylacrylate (Rt ® -U-BOND). This is the prerequisite for the development of quantitative analytical methods based on a stable isotope dilution assay (SIDA) without a mass spectrometric detection (non-MS SIDA). For routine analysis a flame ionization detector (FID) can thus be applied as a robust and low-cost alternative. In a preliminary study, static headspace extraction and gas chromatographic separation (HS-GC-FID) of acetaldehyde in aqueous solutions was shown as an application. Good linearity was obtained in a calibration range from 0.4 to 40mgL -1 , with peak integration benefitting from the inverse isotope effect encountered on the specific porous polymer. Furthermore, separation of methanol and deuterated methanol (d3) could also be achieved under the same chromatographic conditions. The achieved isotopic separation of these important volatile compounds now allows non-MS SIDA-based methods that are still to be developed. Copyright © 2016 Elsevier B.V. All rights reserved.
1976-04-01
spectra are obtained for each peak detected in the CC effluent stream. In this mode of operation, the "total ion current" is usually used as a guide...correcting drift for both magnetic field and electrical field instruments. The peak setting is usually made to the 47 nearest 0.1 amu, and adjustments...su stances by charge transfer from nitric oxide ions (No ), however, the M14 ions are the base peak . This obser- vation by Jardine and Fenselau (44
Characteristic gamma-lactone odor production of the genus Pityrosporum.
Labows, J N; McGinley, K J; Leyden, J J; Webster, G F
1979-01-01
Mass spectrometric-gas chromatographic analysis of culture headspaces revealed that members of the genous Pityrosporum produce volatile gamma-lactones during growth on lipid-containing media. Representative members of other yeast genera found on humans failed to produce these compounds. Addition of lecithin, oleic acids, triolein, or human sebum to the culture media stimulated gamma-lactone production by Pityrosporum species. All yeasts tested produced isopentanol and phenylethanol. Production of gamma-lactones may serve as a valuable characteristic in the identification of organisms of the genus Pityrosporum. PMID:533274
Sideritis romana L. subsp. purpurea (Tal. ex Benth.) Heywood, a new chemotype from Montenegro.
Garzoli, Stefania; Božović, Mijat; Baldisserotto, Anna; Andreotti, Elisa; Pepi, Federico; Tadić, Vanja; Manfredini, Stefano; Ragno, Rino
2018-05-01
A study on essential oil fractions of the Western Balkan endemic Sideritis romana L. subsp. purpurea (Tal. ex Benth.) Heywood collected in Montenegro is reported. The 24-h systematic steam distillation extraction procedure was performed. The gas chromatographic/mass spectrometric (GC/MS) analysis of the fractions showed γ-elemene and spathulenol as two main constituents, revealing a new chemotype of this plant species. Although varying in the content of these two main compounds, which makes the fractions quite different between each other, evaluation of the anti-Candida activity showed the lack of any significant efficacy.
Marsol-Vall, Alexis; Balcells, Mercè; Eras, Jordi; Canela-Garayoa, Ramon
2016-07-01
A novel method consisting of injection-port derivatization coupled to gas chromatography-tandem mass spectrometry is described. The method allows the rapid assessment of 5-hydroxymethylfurfural (HMF) and patulin content in apple and pear derivatives. The chromatographic separation of the compounds was achieved in a short chromatographic run (12.2min) suitable for routine controls of these compounds in the fruit juice industry. The optimal conditions for the injection-port derivatization were at 270°C, 0.5min purge-off, and a 1:2 sample:derivatization reagent ratio (v/v). These conditions represent an important saving in terms of derivatization reagent consumption and sample preparation time. Quality parameters were assessed for the target compounds, giving LOD of 0.7 and 1.6μg/kg and LOQ of 2 and 5μg/kg for patulin and HMF, respectively. These values are below the maximum patulin concentration in food products intended for infants and young children. Repeatability (%RSD n=5) was below 12% for both compounds. In addition, the method linearity ranged between 25 and 1000μg/kg and between 5 and 192μg/kg for HMF and patulin, respectively. Finally, the method was applied to study HMF and patulin content in various fruit juice samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Cappelli Fontanive, Fernando; Souza-Silva, Érica Aparecida; Macedo da Silva, Juliana; Bastos Caramão, Elina; Alcaraz Zini, Claudia
2016-08-26
Diesel and naphtha samples were analyzed using ionic liquid (IL) columns to evaluate the best column set for the investigation of organic sulfur compounds (OSC) and nitrogen(N)-containing compounds analyses with comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry detector (GC×GC/TOFMS). Employing a series of stationary phase sets, namely DB-5MS/DB-17, DB-17/DB-5MS, DB-5MS/IL-59, and IL-59/DB-5MS, the following parameters were systematically evaluated: number of tentatively identified OSC, 2D chromatographic space occupation, number of polyaromatic hydrocarbons (PAH) and OSC co-elutions, and percentage of asymmetric peaks. DB-5MS/IL-59 was chosen for OSC analysis, while IL59/DB-5MS was chosen for nitrogen compounds, as each stationary phase set provided the best chromatographic efficiency for these two classes of compounds, respectively. Most compounds were tentatively identified by Lee and Van den Dool and Kratz retention indexes, and spectra-matching to library. Whenever available, compounds were also positively identified via injection of authentic standards. Copyright © 2016 Elsevier B.V. All rights reserved.
Larson, Tuula; Östman, Conny; Colmsjö, Anders
2011-04-01
The monitoring of radioactive xenon isotopes is one of the principal methods for the detection of nuclear explosions in order to identify clandestine nuclear testing. In this work, a miniaturized, multiple-oven, six-column, preparative gas chromatograph was constructed in order to isolate trace quantities of radioactive xenon isotopes from ambient air, utilizing nitrogen as the carrier gas. The multidimensional chromatograph comprised preparative stainless steel columns packed with molecular sieves, activated carbon, and synthetic carbon adsorbents (e.g., Anasorb®-747 and Carbosphere®). A combination of purification techniques--ambient adsorption, thermal desorption, back-flushing, thermal focusing, and heart cutting--was selectively optimized to produce a well-defined xenon peak that facilitated reproducible heart cutting and accurate quantification. The chromatographic purification of a sample requires approximately 4 h and provides complete separation of xenon from potentially interfering components (such as water vapor, methane, carbon dioxide, and radon) with recovery and accuracy close to 100%. The preparative enrichment process isolates and concentrates a highly purified xenon gas fraction that is suitable for subsequent ultra-low-level γ-, ß/γ-spectroscopic or high-resolution mass spectrometric measurement (e.g., to monitor the gaseous fission products of nuclear explosions at remote locations). The Xenon Processing Unit is a free-standing, relatively lightweight, and transportable system that can be interfaced to a variety of sampling and detection systems. It has a relatively inexpensive, rugged, and compact modular (19-inch rack) design that provides easy access to all parts for maintenance and has a low power requirement.
Copley, M S; Bland, H A; Rose, P; Horton, M; Evershed, R P
2005-06-01
Man's use of illuminants in lamps or as torches to extend the working day and range of environments accessible to him would have been a major technological advance in human civilisation. The most obvious evidence for this in the archaeological record comes from pottery and stone vessels showing sooting due to the use of a wick in conjunction with a lipid-based fuel or illuminant. A wide range of potential fuels would have been exploited depending upon availability and burning requirements. Reported herein are the results of chemical investigations of a number of lamps recovered from excavations of the site of Qasr Ibrim, Egypt. Gas chromatographic, mass spectrometric and stable carbon isotopic analyses of both free (solvent extractable) and 'bound'(released from solvent extracted pottery by base treatment) lipids have revealed a wide range of saturated fatty acids, hydroxy fatty acids and alpha, omega-dicarboxylic acids. Examination of the distributions of compounds and comparisons with the fatty acid compositions of modern plant oils have allowed a range of fats and oils to be recognised. Specific illuminants identified include Brassicaceae (Cruciferae) seed oil (most likely radish oil, Raphanus sativus), castor oil (from Ricinus communis), animal fat, with less diagnostic distributions and delta(13)C values being consistent with low stearic acid plant oils, such as linseed (Linum usitatissimum) or sesame (Sesamum indicum) oils. The identifications of the various oils and fats are supported by parallel investigations of illuminant residues produced by burning various oils in replica pottery lamps. The findings are entirely consistent with the classical writers including Strabo, Pliny and Theophrastrus.
Ribechini, Erika; Modugno, Francesca; Colombini, Maria Perla; Evershed, Richard P
2008-03-07
A combination of gas chromatographic (GC) and mass spectrometric (MS) techniques, including direct exposure-MS (DE-MS), high-temperature GC-MS (HTGC-MS) and GC-MS of neutral and acid fractions, was employed to study the composition and recognise origin of the organic materials used to manufacture balm residues surviving in a series of glass unguentaria recovered from excavations of a Roman villa (Villa B) in the ancient town of Oplontis (Naples, Italy). DE-MS provided comprehensive 'fingerprint' information on the solvent soluble components of the contents of the unguentaria, while GC-MS analyses provided detailed molecular compositions, highlighting the presence of a wide range of compound classes including mid- and long-chain fatty acids, long-chain hydroxy-acids, n-alkanols, alkandiols, n-alkanes, long-chain monoesters, phytosterols and diterpenoid acids. Characteristic biomarkers and their distributions indicate the presence of beeswax, Pinaceae resin and another wax, as the main organic constituents of all of the preparations examined. In particular, the occurrence of phytosterols and long-chain monoesters, in which the acyl moiety was not exclusively palmitic acid, suggested the presence of a second waxy-lipid constituent of plant origin. The results are consistent with beeswax being used in the preparation of the cosmetics preserved in the unguentaria, while the other lipids are most likely the residue of some as yet unidentified plant extract(s), possibly deriving from the cuticular waxes of flowers and/or leaves. The composition of the extracts are consistent with the ancient practices of maceration and/or "enfleurage", in which lipid-based materials, such as beeswax, animal fat or vegetables oils, were used to extract aromatic and fragrant substances from resin, flowers, spices and scented wood, in order to produce unguents and balms.
Structure Determination of Natural Products by Mass Spectrometry.
Biemann, Klaus
2015-01-01
I review laboratory research on the development of mass spectrometric methodology for the determination of the structure of natural products of biological and medical interest, which I conducted from 1958 to the end of the twentieth century. The methodology was developed by converting small peptides to their corresponding polyamino alcohols to make them amenable to mass spectrometry, thereby making it applicable to whole proteins. The structures of alkaloids were determined by analyzing the fragmentation of a known alkaloid and then using the results to deduce the structures of related compounds. Heparin-like structures were investigated by determining their molecular weights from the mass of protonated molecular ions of complexes with highly basic, synthetic peptides. Mass spectrometry was also employed in the analysis of lunar material returned by the Apollo missions. A miniaturized gas chromatograph mass spectrometer was sent to Mars on board of the two Viking 1976 spacecrafts.
Lin, Y W; Hee, S S
1998-07-24
A rapid, reliable and effective method for direct determination of the inert components, manufacturing by-products of the pesticide, and active ingredient in two malathion formulations has been established using capillary gas chromatography-mass spectrometry (GC-MS) with the internal standard method. The C2-, C3-, and C4-alkylbenzenes, the major pesticide manufacturing by-products (O,O,S-trimethylthionophosphate, diethyl maleate and O,O,O-trimethylthionophosphate), and malathion were resolved, and quantified in the same chromatogram. Structural identification was based on MS total ion current data, comparison of GC retention times with those of authentic standards, and retention indices. O,O,S-Trimethylthionophosphate was quantified at 3.57 +/- 0.31% (w/w) in one malathion formulation. While the malathion contents were within specifications for both formulations, the total alkylbenzene contents were not.
USDA-ARS?s Scientific Manuscript database
Flavonoids in different spinach genotypes were separated, identified, and quantified by a high-performance liquid chromatographic method with photodiode array and mass spectrometric detection. The antioxidant capacities of the genotypes were also measured using two antioxidant assays - oxygen radica...
Qian, Mingrong; Zhang, Hu; Wu, Liqin; Jin, Nuo; Wang, Jianmei; Jiang, Kezhi
2015-01-01
A sensitive gas chromatographic-triple quadrupole mass spectrometric (GC-QqQ MS) analytical method, for the determination of zearalenone and its five derivatives in edible vegetable oil, was developed. After the vegetable oil samples were prepared using gel permeation chromatography, the eluent was collected, evaporated and dried with nitrogen gas. The residue was silylated with N,O-bis-trimethylsilyltrifluoroacetamide, containing 1% trimethylchlorosilane. GC-QqQ MS was performed in the reaction-monitoring mode to confirm and quantify mycotoxins in vegetable oil. The limits of quantitation were 0.03-0.2 μg kg(-1) for the six mycotoxins. The average recoveries, measured at 2, 20 and 200 μg kg(-1), were in the range 80.3-96.5%. Zearalenone was detected in the range 5.2-184.6 μg kg(-1) in nine maize oils and at 40.7 μg kg(-1) in a rapeseed oil from the local market. Copyright © 2014 Elsevier Ltd. All rights reserved.
Sciarrone, Danilo; Costa, Rosaria; Ragonese, Carla; Tranchida, Peter Quinto; Tedone, Laura; Santi, Luca; Dugo, Paola; Dugo, Giovanni; Joulain, Daniel; Mondello, Luigi
2011-01-07
The production and trade of Indian sandalwood oil is strictly regulated, due to the impoverishment of the plantations; for such a reason, Australian sandalwood oil has been evaluated as a possible substitute of the Indian type. International directives report, for both the genuine essential oils, specific ranges for the sesquiterpene alcohols (santalols). In the present investigation, a multidimensional gas chromatographic system (MDGC), equipped with simultaneous flame ionization and mass spectrometric detection (FID/MS), has been successfully applied to the analysis of a series of sandalwood oils of different origin. A detailed description of the system utilized is reported. Three santalol isomers, (Z)-α-trans-bergamotol, (E,E)-farnesol, (Z)-nuciferol, epi-α-bisabolol and (Z)-lanceol have been quantified. LoD (MS) and LoQ (FID) values were determined for (E,E)-farnesol, used as representative of the oxygenated sesquiterpenic group, showing levels equal to 0.002% and 0.003%, respectively. A great advantage of the instrumental configuration herein discussed, is represented by the fact that identification and quantitation of target analytes are carried out in one step, without the need to perform two separate analyses. Copyright © 2010 Elsevier B.V. All rights reserved.
Unidentified Organic Compounds. For target analytes, standards are purchased, extraction and clean-up procedures are optimized, and mass spectra and retention times for the chromatographic separation are obtained for comparison to the target compounds in environmental sample ...
Meyer, M.T.; Mills, M.S.; Thurman, E.M.
1993-01-01
An automated solid-phase extraction (SPE) method was developed for the pre-concentration of chloroacetanilide and triazine herbicides, and two triazine metabolites from 100-ml water samples. Breakthrough experiments for the C18 SPE cartridge show that the two triazine metabolites are not fully retained and that increasing flow-rate decreases their retention. Standard curve r2 values of 0.998-1.000 for each compound were consistently obtained and a quantitation level of 0.05 ??g/l was achieved for each compound tested. More than 10,000 surface and ground water samples have been analyzed by this method.
Contribution to the identification of pyrolysis byproducts in fluidized bed soot and in pyrocarbon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolfrum, E.; Rottmann, J.; Bueker, I.
1973-01-15
In order to develop improved fuel particles, pyrohysis byproducts of both the pyrocarbon separated in fluidized beds and the resulting soot were studied. The aim was to study the separation mechanism of pyrocarbon on fuel kernels during the thermal decomposition of low hydrocarbons. This study referred to pyrolysis products of acetylene and propylene. The extraction was performed with various methods. The extracts were separated gas- chromatographically and mass-spectrometrically; the single components were partially identified. 21 polycyclic and aromatic hydrocarbons were clearly identified in soot. Beyond that, pyrocarbon contains still higher molecular pohycyclic compounds. (18 figures, 12 tables, 34 references) (auth)
2006-08-01
conditions will necessarily be supercritical fluids . These temperatures and pressures will also cause the fuel to undergo pyrolytic reactions, which...Spectrometric Detection for 5a. CONTRACT NUMBER Analysis of Supercritical Fuels Pyrolysis Products 5b. GRANT NUMBER FA9550-05-1-0253 5c... supercritical pyrolysis experiments with the model fuels 1-methylnaphthalene and toluene. The HPLC/UV/MS instrument facilitated the identification of fifteen 5
NASA Technical Reports Server (NTRS)
Anderson, D. M.; Biemann, K.; Orgel, L. E.; Oro, J.; Owen , T.; Shulman, G. P.; Toulmin, P., III; Urey, H. C.
1972-01-01
An experiment centering around a mass spectrometer is described, which is aimed at the identification of organic substances present in the top 10 cm of the surface of Mars and an analysis of the atmosphere for major and minor constituents as well as isotopic abundances. In addition, an indication of the abundance of water in the surface and some information concerning the mineralogy can be obtained by monitoring the gases produced upon heating the soil sample. The organic material will simply be expelled by heating to 150, 300, and 500 C into the carrier gas stream of a gas chromatograph interfaced to the mass spectrometer or by slowly heating the sample in direct communication with the spectrometer. It is planned to analyze a total of up to nine soil samples in order to study diurnal and seasonal variations. The system is designed to give useful data even for minor constituents if the total of organics should be as low as 5 ppm. The spectrometer covers the mass range of 12-200 with adequate resolution.
In-injection port thermal desorption for explosives trace evidence analysis.
Sigman, M E; Ma, C Y
1999-10-01
A gas chromatographic method utilizing thermal desorption of a dry surface wipe for the analysis of explosives trace chemical evidence has been developed and validated using electron capture and negative ion chemical ionization mass spectrometric detection. Thermal desorption was performed within a split/splitless injection port with minimal instrument modification. Surface-abraded Teflon tubing provided the solid support for sample collection and desorption. Performance was characterized by desorption efficiency, reproducibility, linearity of the calibration, and method detection and quantitation limits. Method validation was performed with a series of dinitrotoluenes, trinitrotoluene, two nitroester explosives, and one nitramine explosive. The method was applied to the sampling of a single piece of debris from an explosion containing trinitrotoluene.
Masci, Maurizio; Orban, Elena; Nevigato, Teresina
2015-01-02
A simple instrumental procedure was developed to carry out the not simple analysis of PCBs in fish samples. PCBs with the same degree of chlorination (the isomers) are expected to be totally indistinguishable among them by all existing detectors and by all existing mass spectrometers, and there is no apparent solution in those frequent cases where two isomers chromatographically coelute. Generally such coelutions are solved by means of multidimensional GC, but it is a complex technique impractical for most laboratories. The present research focuses on the seven important "indicator PCBs" by using the mass spectrometer in an innovative way. The "mass spectrometric ortho effect" was usefully exploited in addressing coelutions between isomers. Other new important observations on mass spectra were decisive in solving the apparent problem arising from coelutions between higher chlorinated PCBs with the lower chlorinated ones when low-resolution MS is used. With the proposed procedure, the seven indicators are analyzed in a simple way and with a degree of accuracy never observed with the conventional gas chromatography. The method was applied to some Bluefin Tuna fish samples of big size suspected to have not negligible levels of PCBs due to the high position of this species in the food chain. The supposition was partly confirmed. On the basis of the results here obtained, the recently introduced EU Regulation on six of the seven indicators shows one critical point: in the present paper, an amendment to the Regulation is proposed. A number of important validation measures are reported. Copyright © 2014 Elsevier B.V. All rights reserved.
Determination of stable carbon and hydrogen isotopes of light hydrocarbons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dumke, I.; Faber, E.; Poggenburg, J.
1989-10-01
A combined system for the measurement of {sup 13}C/{sup 12}C and D/H ratios on light hydrocarbons (C{sub 1}-C{sub 3}) and CO{sub 2} is described. The system is designed for natural gas and sediment gas analyses. It comprises gas chromatographic separation with online combustion of hydrocarbons to CO{sub 2} and H{sub 2}O, reduction of H{sub 2}O to H{sub 2} on zinc in closed ampules, and mass spectrometric determination of isotope ratios ({delta}{sup 13}C, {delta}D) using a mass spectrometer inlet system especially designed for low hydrogen gas quantities. Isotope analyses can be carried out in the range of 3-10,000 {mu}L of CO{submore » 2} and 100-10,000 {mu}L of H{sub 2} (gas quantities converted from sample compounds during preparation, STP). Including all preparation steps, reproducibility of isotope values for large sample quantities (>100 {mu}L of produced CO{sub 2} and >1,000 {mu}L of produced H{sub 2}). is {plus minus}0.2{per thousand} for {delta}{sup 13}C and {plus minus}3{per thousand} for {delta}D.« less
Separation and Analysis of Citral Isomers.
ERIC Educational Resources Information Center
Sacks, Jeff; And Others
1983-01-01
Provides background information, procedures, and results of an experiments designed to introduce undergraduates to the technique of steam distillation as a means of isolating thermally sensitive compounds. Chromatographic techniques (HPLC) and mass spectrometric analysis are used in the experiment which requires three laboratory periods. (JN)
Enantioselective comprehensive two-dimensional gas chromatography of lavender essential oil.
Krupčík, Ján; Gorovenko, Roman; Špánik, Ivan; Armstrong, Daniel W; Sandra, Pat
2016-12-01
The enantiomeric composition of several chiral markers in lavender essential oil was studied by flow modulated comprehensive two-dimensional gas chromatography operated in the reverse flow mode and hyphenated to flame ionization and quadrupole mass spectrometric detection. Two capillary column series were used in this study, 2,3-di-O-ethyl-6-O-tert-butyldimethylsilyl-β-cyclodextrin or 2,3,6-tri-O-methyl-β-cyclodextrin, as the chiral column in the first dimension and α polyethylene glycol column in the second dimension. Combining the chromatographic data obtained on these column series, the enantiomeric and excess ratios for α-pinene, β-pinene, camphor, lavandulol, borneol, and terpinen-4-ol were determined. This maybe a possible route to assess the authenticity of lavender essential oil. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Aguilera-Herrador, Eva; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel
2008-08-01
The direct coupling between ionic liquid-based single-drop microextraction and gas chromatography/mass spectrometry is proposed for the rapid and simple determination of benzene, toluene, ethylbenzene and xylenes isomers (BTEX) in water samples. The extraction procedure exploits not only the high affinity of the selected ionic liquid (1-methyl-3-octyl-imidazolium hexaflourophosphate) to these aromatic compounds but also its special properties like viscosity, low vapour pressure and immiscibility with water. All the variables involved in the extraction process have been studied in depth. The developed method allows the determination of these single-ring compounds in water under the reference concentration level fixed by the international legislation. In this case, limits of detection were in the range 20 ng L(-1) (obtained for benzene) and 91 ng L(-1) (for o-xylene). The repeatability of the proposed method, expressed as RSD (n=5), varied between 3.0% (o-xylene) and 5.2% (toluene).
Wenig, Philip; Odermatt, Juergen
2010-07-30
Today, data evaluation has become a bottleneck in chromatographic science. Analytical instruments equipped with automated samplers yield large amounts of measurement data, which needs to be verified and analyzed. Since nearly every GC/MS instrument vendor offers its own data format and software tools, the consequences are problems with data exchange and a lack of comparability between the analytical results. To challenge this situation a number of either commercial or non-profit software applications have been developed. These applications provide functionalities to import and analyze several data formats but have shortcomings in terms of the transparency of the implemented analytical algorithms and/or are restricted to a specific computer platform. This work describes a native approach to handle chromatographic data files. The approach can be extended in its functionality such as facilities to detect baselines, to detect, integrate and identify peaks and to compare mass spectra, as well as the ability to internationalize the application. Additionally, filters can be applied on the chromatographic data to enhance its quality, for example to remove background and noise. Extended operations like do, undo and redo are supported. OpenChrom is a software application to edit and analyze mass spectrometric chromatographic data. It is extensible in many different ways, depending on the demands of the users or the analytical procedures and algorithms. It offers a customizable graphical user interface. The software is independent of the operating system, due to the fact that the Rich Client Platform is written in Java. OpenChrom is released under the Eclipse Public License 1.0 (EPL). There are no license constraints regarding extensions. They can be published using open source as well as proprietary licenses. OpenChrom is available free of charge at http://www.openchrom.net.
Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli (Lucy)
2014-01-01
Sweet basil, Ocimum basilicum., is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1 min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. PMID:24518341
Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli Lucy
2014-07-01
Sweet basil, Ocimum basilicum, is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. Copyright © 2014 Elsevier Ltd. All rights reserved.
Nagashima, Hisayuki; Kondo, Tomohide; Nagoya, Tomoki; Ikeda, Toru; Kurimata, Naoko; Unoke, Shohei; Seto, Yasuo
2015-08-07
A field-portable gas chromatograph-mass spectrometer (Hapsite ER system) was evaluated for the detection of chemical warfare agents (CWAs) in the vapor phase. The system consisted of Tri-Bed concentrator gas sampler (trapping time: 3s(-1)min), a nonpolar low thermal-mass capillary gas chromatography column capable of raising temperatures up to 200°C, a hydrophobic membrane-interfaced electron ionization quadrupole mass spectrometer evacuated by a non-evaporative getter pump for data acquisition, and a personal computer for data analysis. Sample vapors containing as little as 22μg sarin (GB), 100μg soman (GD), 210μg tabun (GA), 55μg cyclohexylsarin (GF), 4.8μg sulfur mustard, 390μg nitrogen mustard 1, 140μg of nitrogen mustard 2, 130μg nitrogen mustard 3, 120μg of 2-chloroacetophenone and 990μg of chloropicrin per cubic meter could be confirmed after Tri-Bed micro-concentration (for 1min) and automated AMDIS search within 12min. Using manual deconvolution by background subtraction of neighboring regions on the extracted ion chromatograms, the above-mentioned CWAs could be confirmed at lower concentration levels. The memory effects were also examined and we found that blister agents showed significantly more carry-over than nerve agents. Gasoline vapor was found to interfere with the detection of GB and GD, raising the concentration limits for confirmation in the presence of gasoline by both AMDIS search and manual deconvolution; however, GA and GF were not subject to interference by gasoline. Lewisite 1, and o-chlorobenzylidene malononitrile could also be confirmed by gas chromatography, but it was hard to quantify them. Vapors of phosgene, chlorine, and cyanogen chloride could be confirmed by direct mass spectrometric detection at concentration levels higher than 2, 140, and 10mg/m(3) respectively, by bypassing the micro-concentration trap and gas chromatographic separation. Copyright © 2015 Elsevier B.V. All rights reserved.
Beloborodova, N V; Arkhipova, A S; Beloborodov, D M; Boĭko, N B; Mel'ko, A I; Olenin, A Iu
2006-02-01
The investigation quantitatively determined the content of low-molecular-weight aromatic compounds of microbial origin in the sera of 34 individuals by chromatographic mass spectrometry. An "Agilent Technogies 6890N" gas chromatograph with a 5973 mass selective detector was applied; chromatographic separation of components was effected on an Hp-5MS quartz capillary column. Aromatic small molecules originating from microbes (SMOM) were determined in the sera of 7 patients with sepsis. The diagnosis of sepsis was documented by the presence of the systemic inflammation syndrome and by that of bacteriemia and/or artificial ventilation-associated pneumonia along with the level of procalcitonin of higher than 10 ng/ml. The levels of aromatic SMOM were compared in 10 healthy donors, 8 preoperative cardiosurgical patients, and 9 patients with different abnormalities without sepsis treated in an intensive care unit (ICU). Serum phenylacetic and 3-phenylpropionic acids were found to be prevalent in the healthy donors and postoperative cardiosurgical patients. In ICU patients with different complications without sepsis, more than half the compounds under study were undetectable, the others were found in very low concentrations, which may be accounted for by antibiotic therapy. At the same time, almost the whole spectrum of the test compounds (other than 3-phenylpropionic acid) with the highest concentrations of 3-phenyllactic, p-hydroxyphenylacetic, 3-(p-hydroxyphenyl)lactic and 2-hydroxybutanic acids, was detectable in septic patients receiving a more intensive therapy. The differences were statistically significant (by the Mann-Whitney U-test; p < 0.05). By taking into account the potentially high biological activity of the test compounds, studies are to be continued in this area.
Portable gas chromatograph-mass spectrometer
Andresen, Brian D.; Eckels, Joel D.; Kimmons, James F.; Myers, David W.
1996-01-01
A gas chromatograph-mass spectrometer (GC-MS) for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units.
Chua, Hoe-Chee; Lee, Hoi-Sim; Sng, Mui-Tiang
2006-01-13
Analysing nitrogen mustards and their degradation products in decontamination emulsions posed a significant challenge due to the different phases present in such matrices. Extensive sample preparation may be required to isolate target analytes. Furthermore, numerous reaction products are formed in the decontamination emulsion. A fast and effective qualitative screening procedure was developed for these compounds, using liquid chromatography-mass spectrometry (LC-MS). This eliminated the need for additional sample handling and derivatisation that are required for gas chromatographic-mass spectrometric (GC-MS) analysis. A liquid chromatograph with mixed mode column and isocratic elution gave good chromatography. The feasibility of applying this technique for detecting these compounds in spiked water and decontamination emulsion was demonstrated. Detailed characterisation of the degradation products in these two matrices was carried out. The results demonstrated that N-methyldiethanolamine (MDEA), N-ethyldiethanolamine (EDEA) and triethanolamine (TEA) are not the major degradation products of their respective nitrogen mustards. Degradation profiles of nitrogen mustards in water were also established. In verification analysis, it is important not only to develop methods for the identification of the actual chemical agents; the methods must also encompass degradation products of the chemical agents as well so as to exclude false negatives. This study demonstrated the increasingly pivotal role that LC-MS play in verification analysis.
USDA-ARS?s Scientific Manuscript database
Angelica sinensis (Oliv.) Diels (“Danggui” in Chinese) is one of the most commonly used Traditional Chinese Medicines (TCMs). It has been used to invigorate blood circulation for the treatment of anemia, hypertension, chronic bronchitis, asthma, rheumatism and cardiovascular diseases. There are a lo...
New phenolic components and chromatographic profiles of green and fermented teas
USDA-ARS?s Scientific Manuscript database
A standardized profiling method based on liquid chromatography with diode array and electrospray ionization/mass spectrometric detection (LC-DAD-ESI/MS) was applied to establish the phenolic profiles of 41 green teas and 25 fermented teas. More than 80 phenolic compounds were either identified that ...
Morita, N; Shibahara, A; Yamamoto, K; Shinkai, K; Kajimoto, G; Okuyama, H
1993-02-01
Vibrio sp. strain ABE-1 was grown in a medium that contained as its stable isotope tracer either [2,2-2H2]cis-9-hexadecenoic or [2,2-2H2]trans-9-hexadecenoic acid. Gas chromatographic-mass spectrometric analysis of the cis-9-hexadecenoic and trans-9-hexadecenoic acid fractions from the cells revealed the formation of an intracellularly isomerized 2,2-2H2-fatty acid which differed from the tracer only in the geometrical configuration of the double bond. This observation shows that cis-trans isomerization without a shift in double-bond position between these two geometric hexadecenoic acid isomers can occur in the cells.
Morita, N; Shibahara, A; Yamamoto, K; Shinkai, K; Kajimoto, G; Okuyama, H
1993-01-01
Vibrio sp. strain ABE-1 was grown in a medium that contained as its stable isotope tracer either [2,2-2H2]cis-9-hexadecenoic or [2,2-2H2]trans-9-hexadecenoic acid. Gas chromatographic-mass spectrometric analysis of the cis-9-hexadecenoic and trans-9-hexadecenoic acid fractions from the cells revealed the formation of an intracellularly isomerized 2,2-2H2-fatty acid which differed from the tracer only in the geometrical configuration of the double bond. This observation shows that cis-trans isomerization without a shift in double-bond position between these two geometric hexadecenoic acid isomers can occur in the cells. PMID:8423164
Gas chromatographic--mass spectrometric quantitation of 16, 16-dimethyl-trans-delta 2-PGE1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dimov, V.; Green, K.; Bygdeman, M.
1983-02-01
Di-deuterated and di-tritiated 16,16-dimethyl-trans-delta 2-PGE1 has been synthesized and used for development of a GC-MS method for quantitation of corresponding unlabelled drug in patient plasma. Although these carrier/internal standard molecules only contain 2 deuterium atoms the lower limit of detection at each injection is as low as about 40 pg. The maximum plasma levels of this drug following administration of vaginal suppositories used in clinical studies (1 mg 16,16-dimethyl-trans-delta 2-PGE1 methyl ester in 0.8 g Witepsol S-52) were 100-350 pg/ml i.e. in the same order of magnitude as earlier seen for 16,16-dimethyl-PGE2.
Quantitative mass spectrometry of unconventional human biological matrices
NASA Astrophysics Data System (ADS)
Dutkiewicz, Ewelina P.; Urban, Pawel L.
2016-10-01
The development of sensitive and versatile mass spectrometric methodology has fuelled interest in the analysis of metabolites and drugs in unconventional biological specimens. Here, we discuss the analysis of eight human matrices-hair, nail, breath, saliva, tears, meibum, nasal mucus and skin excretions (including sweat)-by mass spectrometry (MS). The use of such specimens brings a number of advantages, the most important being non-invasive sampling, the limited risk of adulteration and the ability to obtain information that complements blood and urine tests. The most often studied matrices are hair, breath and saliva. This review primarily focuses on endogenous (e.g. potential biomarkers, hormones) and exogenous (e.g. drugs, environmental contaminants) small molecules. The majority of analytical methods used chromatographic separation prior to MS; however, such a hyphenated methodology greatly limits analytical throughput. On the other hand, the mass spectrometric methods that exclude chromatographic separation are fast but suffer from matrix interferences. To enable development of quantitative assays for unconventional matrices, it is desirable to standardize the protocols for the analysis of each specimen and create appropriate certified reference materials. Overcoming these challenges will make analysis of unconventional human biological matrices more common in a clinical setting. This article is part of the themed issue 'Quantitative mass spectrometry'.
Grindstaff, Quirinus G.
1992-01-01
Described is a new gas chromatograph-mass spectrometer (GC/MS) system and method for quantitative analysis of reactive chemical compounds. All components of such a GC/MS system external to the oven of the gas chromatograph are programmably temperature controlled to operate at a volatilization temperature specific to the compound(s) sought to be separated and measured.
Portable gas chromatograph-mass spectrometer
Andresen, B.D.; Eckels, J.D.; Kimmons, J.F.; Myers, D.W.
1996-06-11
A gas chromatograph-mass spectrometer (GC-MS) is described for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units. 4 figs.
Leung, Elvis M K; Chan, Wan
2014-02-01
Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.
USDA-ARS?s Scientific Manuscript database
A liquid chromatographic-tandem mass spectrometric (LC-MS/MS) multi-residue method for the simultaneous quantification and identification of 38 residues of the most widely used anthelmintic veterinary drugs (including benzimidazoles, macrocyclic lactones, and flukicides) in milk and liver has been d...
Lee, Heon-Woo; Seo, Ji-Hyung; Choi, Seung-Ki; Lee, Kyung-Tae
2007-01-30
A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5>166.1 for itopride and m/z 342.3>111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2=0.9999) over the studied range (0.5-1000 ng mL(-1)) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.
Ma, Huiying; Zhang, Keke; Jiang, Qing; Dai, Diya; Li, Hongli; Bi, Wentao; Chen, David Da Yong
2018-04-27
Plant polysaccharides have numerous medicinal functions. Due to the differences in their origins, regions of production, and cultivation conditions, the quality and the functions of polysaccharides can vary significantly. They are macromolecules with large molecular weight (MW) and complex structure, and pose great challenge for the analytical technology used. Taking Dendrobium officinale (DO) from various origins and locations as model samples. In this investigation, mechanochemical extraction method was used to successfully extract polysaccharides from DO using water as solvent, the process is simple, fast (40 s) and with high yield. The MWs of the intact saccharides from calibration curve and light scattering measurement were determined and compared after separation with size exclusion chromatography (SEC). The large polysaccharide was acid hydrolyzed to oligosaccharides and the products were efficiently separated and identified using liquid chromatography coupled to a high resolution tandem mass spectrometry (LC-MS 2 ). Obvious differences were observed among LC-MS 2 chromatograms of digested products, and the chemical structures for the products were proposed based on accurate mass values. More importantly, isomeric digested carbohydrate compounds were explored and characterized. All the chromatographic and mass spectrometric results in this study provided a multi-dimensional characterization, fingerprint analysis, and molecular structure level assessment of plant polysaccharides. Copyright © 2018 Elsevier B.V. All rights reserved.
Carrillo-Carrión, Carolina; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel
2007-11-09
BTEX-S compounds are widely distributed in the environment and can be present in different foodstuffs, including olive oil. Taking into account the risks of the exposure to these compounds, analytical methods for their determination in different matrices are mandatory. In this paper, the use of surfactant-coated multiwalled carbon nanotubes as additive in liquid-liquid extraction is applied for the determination of single-ring aromatic compounds in olive oil samples. After sample treatment, the aqueous extracts are subsequently analyzed by headspace/gas chromatography/mass spectrometry allowing the determination of BTEX-S within ca. 15 min. Each stage of the proposed LLE/HS/GC/MS configuration involves a selectivity enhancement avoiding the interference of other compounds of the sample matrix. Limits of detection were in the range 0.25 ng mL(-1) (obtained for ethylbenzene) and 0.43 ng mL(-1) (for benzene). The repeatability of the proposed method expressed as RSD varied between 1.9% (styrene) and 3.3% (benzene) (n=11).
Strano-Rossi, Sabina; Molaioni, Francesco; Rossi, Francesca; Botrè, Francesco
2005-01-01
This paper describes a rapid gas chromatographic/mass spectrometric (GC/MS) screening method for the detection of drugs of abuse and/or their metabolites in urine. Synthetic stimulants, opiates, cocaine metabolites, cannabinoids--and specifically the acid metabolite of tetrahydrocannabinol (THC-COOH)--can be simultaneously extracted by a single liquid/liquid separation step, at alkaline pH, and assayed as trimethylsilyl derivatives by GC/MS in SIM (selected ion monitoring) mode. All the analytes show a good linearity (R2 > 0.99 for most of the considered substances) in the range 25-1000 ng/mL, with a good reproducibility of both the retention times (CV% <0.7) and the relative abundances of the characteristic diagnostic ions (CV% <13). The limit of detection (LOD) of the method is 25 ng/mL of target compound in human urine for most of the substances investigated, 3 ng/mL for THC-COOH, and 10 ng/mL for norbuprenorphine. Validation of the method allows its application to different fields of forensic analytical toxicology, including antidoping analysis.
Analysis of confiscated black market drugs using chromatographic and mass spectrometric approaches.
Thevis, Mario; Schrader, Yvonne; Thomas, Andreas; Sigmund, Gerd; Geyer, Hans; Schänzer, Wilhelm
2008-04-01
In the context of house searches in Germany, numerous drugs were confiscated and subjected to chemical analysis, including anabolic agents such as various anabolic-androgenic steroids (stanozolol, testosterone derivatives, trenbolone esters, etc.) and clenbuterol, as well as agents with anti-estrogenic activity (tamoxifen, clomiphene), drugs stimulating virility (sildenafil, tadalafil), and unlabeled plastic bags. Liquid chromatography-tandem mass spectrometry, gas chromatography-mass spectrometry with nitrogen-phosphorus specific detection, gel electrophoresis, and immunological tests were employed to test for the effective content of 70 products. In 18 cases (25.7%), the declared ingredients differed from the actual content, in particular concerning anabolic-androgenic steroids. Nandrolone and trenbolone esters, for instance, were frequently substituted or complemented by various testosterone derivatives, and several testosterone depot formulations originally composed of four different esters were found to contain fewer or wrong components. Except for those drugs supposedly originating from so-called underground labs, fake packings were hardly or not distinguishable from original boxes by visual inspection.
Tiscione, Nicholas B; Alford, Ilene; Yeatman, Dustin Tate; Shan, Xiaoqin
2011-09-01
Ethanol is the most frequently identified compound in forensic toxicology. Although confirmation involving mass spectrometry is desirable, relatively few methods have been published to date. A novel technique utilizing a Dean's Switch to simultaneously quantitate and confirm ethyl alcohol by flame-ionization (FID) and mass spectrometric (MS) detection after headspace sampling and gas chromatographic separation is presented. Using 100 μL of sample, the limits of detection and quantitation were 0.005 and 0.010 g/dL, respectively. The zero-order linear range (r(2) > 0.990) was determined to span the concentrations of 0.010 to 1.000 g/dL. The coefficient of variation of replicate analyses was less than 3.1%. Quantitative accuracy was within ±8%, ±6%, ±3%, and ±1.5% at concentrations of 0.010, 0.025, 0.080, and 0.300 g/dL, respectively. In addition, 1,1-difluoroethane was validated for qualitative identification by this method. The validated FID-MS method provides a procedure for the quantitation of ethyl alcohol in blood by FID with simultaneous confirmation by MS and can also be utilized as an identification method for inhalants such as 1,1-difluoroethane.
NASA Technical Reports Server (NTRS)
Gehrke, Charles W.; Ponnamperuma, Cyril; Kuo, Kenneth C.; Stalling, David L.; Zumwalt, Robert W.
1989-01-01
An investigation of the returned Mars samples for biologically important organic compounds, with emphasis on amino acid, the puring and pyrimidine bases, and nucleosides is proposed. These studies would be conducted on subsurface samples obtained by drilling past the surface oxidizing layer with emphasis on samples containing the larges quantities of organic carbon as determined by the rover gas chromatographic mass spectrometer (GCMS). Extraction of these molecules from the returned samples will be performed using the hydrothermal extraction technique described by Cheng and Ponnamperuma. More rigorous extraction methods will be developed and evaluated. For analysis of the extract for free amino acids or amino acids present in a bound or peptidic form, aliquots will be analyzed by capillary GCMS both before and after hydrolysis with 6N hydrochloric acid. Establishment of the presence of amino acids would then lead to the next logical step which would be the use of chiral stationary gas chromatography phases to determine the enatiomeic composition of the amino acids present, and thus potentially establish their biotic or abiotic origin. Confirmational analyses for amino acids would include ion-exchange and reversed-phase liquid chromatographic analysis. For analyses of the returned Mars samples for nucleobases and nucleosides, affinity and reversed-phase liquid chromatography would be utilized. This technology coupled with scanning UV detection for identification, presents a powerful tool for nucleobase and nucleoside analysis. Mass spectrometric analysis of these compounds would confirm their presence in samples returned form Mars.
Preparation of pyrolysis reference samples: evaluation of a standard method using a tube furnace.
Sandercock, P Mark L
2012-05-01
A new, simple method for the reproducible creation of pyrolysis products from different materials that may be found at a fire scene is described. A temperature programmable steady-state tube furnace was used to generate pyrolysis products from different substrates, including softwoods, paper, vinyl sheet flooring, and carpet. The temperature profile of the tube furnace was characterized, and the suitability of the method to reproducibly create pyrolysates similar to those found in real fire debris was assessed. The use of this method to create proficiency tests to realistically test an examiner's ability to interpret complex gas chromatograph-mass spectrometric fire debris data, and to create a library of pyrolsates generated from materials commonly found at a fire scene, is demonstrated. © 2011 American Academy of Forensic Sciences.
Analysis of Glycosaminoglycans Using Mass Spectrometry
Staples, Gregory O.; Zaia, Joseph
2015-01-01
The glycosaminoglycans (GAGs) are linear polysaccharides expressed on animal cell surfaces and in extracellular matrices. Their biosynthesis is under complex control and confers a domain structure that is essential to their ability to bind to protein partners. Key to understanding the functions of GAGs are methods to determine accurately and rapidly patterns of sulfation, acetylation and uronic acid epimerization that correlate with protein binding or other biological activities. Mass spectrometry (MS) is particularly suitable for the analysis of GAGs for biomedical purposes. Using modern ionization techniques it is possible to accurately determine molecular weights of GAG oligosaccharides and their distributions within a mixture. Methods for direct interfacing with liquid chromatography have been developed to permit online mass spectrometric analysis of GAGs. New tandem mass spectrometric methods for fine structure determination of GAGs are emerging. This review summarizes MS-based approaches for analysis of GAGs, including tissue extraction and chromatographic methods compatible with LC/MS and tandem MS. PMID:25705143
USDA-ARS?s Scientific Manuscript database
A fuzzy chromatography mass spectrometric (FCMS) fingerprinting method combined with chemometric analysis was established to diffrentiate between whole wheat (WW) flours and refined wheat (RW) flour, and the breads made from them. The chemical compositions of the bread samples were profiled using h...
An analytical method to identify and quantify trace levels of C5 to C12 perfluorocarboxylic acids (PFCAs) in articles of commerce (AOC) is developed and rigorously validated. Solid samples were extracted in methanol, and liquid samples were diluted with a solvent consisting of 60...
Barker, S A; Littlefield-Chabaud, M A; David, C
2001-02-10
A method for the solid-phase extraction (SPE) and liquid chromatographic-atmospheric pressure chemical ionization-mass spectrometric-mass spectrometric-isotope dilution (LC-APcI-MS-MS-ID) analysis of the indole hallucinogens N,N-dimethyltryptamine (DMT) and 5-methoxy DMT (or O-methyl bufotenin, OMB) from rat brain tissue is reported. Rats were administered DMT or OMB by the intraperitoneal route at a dose of 5 mg/kg and sacrificed 15 min post treatment. Brains were dissected into discrete areas and analyzed by the methods described as a demonstration of the procedure's applicability. The synthesis and use of two new deuterated internal standards for these purposes are also reported.
Advances in structure elucidation of small molecules using mass spectrometry
Fiehn, Oliver
2010-01-01
The structural elucidation of small molecules using mass spectrometry plays an important role in modern life sciences and bioanalytical approaches. This review covers different soft and hard ionization techniques and figures of merit for modern mass spectrometers, such as mass resolving power, mass accuracy, isotopic abundance accuracy, accurate mass multiple-stage MS(n) capability, as well as hybrid mass spectrometric and orthogonal chromatographic approaches. The latter part discusses mass spectral data handling strategies, which includes background and noise subtraction, adduct formation and detection, charge state determination, accurate mass measurements, elemental composition determinations, and complex data-dependent setups with ion maps and ion trees. The importance of mass spectral library search algorithms for tandem mass spectra and multiple-stage MS(n) mass spectra as well as mass spectral tree libraries that combine multiple-stage mass spectra are outlined. The successive chapter discusses mass spectral fragmentation pathways, biotransformation reactions and drug metabolism studies, the mass spectral simulation and generation of in silico mass spectra, expert systems for mass spectral interpretation, and the use of computational chemistry to explain gas-phase phenomena. A single chapter discusses data handling for hyphenated approaches including mass spectral deconvolution for clean mass spectra, cheminformatics approaches and structure retention relationships, and retention index predictions for gas and liquid chromatography. The last section reviews the current state of electronic data sharing of mass spectra and discusses the importance of software development for the advancement of structure elucidation of small molecules. Electronic supplementary material The online version of this article (doi:10.1007/s12566-010-0015-9) contains supplementary material, which is available to authorized users. PMID:21289855
Trace Gas Analyzer (TGA) program
NASA Technical Reports Server (NTRS)
1977-01-01
The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.
Mass Spectrometric Analysis of Synthetic Organic Pigments.
Sugaya, Naeko; Takahashi, Mitsuko; Sakurai, Katsumi; Tanaka, Nobuko; Okubo, Ichiro; Kawakami, Tsuyoshi
2018-04-18
Though synthetic organic colorants are used in various applications nowadays, there is the concern that impurities by-produced during the manufacturing and degradation products in some of these colorants are persistent organic pollutants and carcinogens. Thus, it is important to identify the synthetic organic colorants in various products, such as commercial paints, ink, cosmetics, food, textile, and plastics. Dyes, which are soluble in water and other solvents, could be analyzed by chromatographic methods. In contrast, it is difficult to analyze synthetic organic pigments by these methods because of their insolubility. This review is an overview of mass spectrometric analysis of synthetic organic pigments by various ionization methods. We highlight a recent study of textile samples by atmospheric pressure solid analysis probe MS. Furthermore, the mass spectral features of synthetic organic pigments and their separation from other components such as paint media and plasticizers are discussed.
Thermal Stability of Distillate Hydrocarbon Fuels. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Reddy, Kishenkumar Tadisina; Cernansky, Nicholas P.
1987-01-01
Thermal stability of fuels is expected to become a severe problem in the future due to the anticipated use of broadened specification and alternative fuels. Future fuels will have higher contents of heteroatomic species which are reactive constituents and are known to influence fuel degradation. To study the degradation chemistry of selected model fuels, n-dodecane and n-dodecane plus heteroatoms were aerated by bubbling air through the fuels amd stressed on a modified Jet Fuel Thermal Oxidation Tester facility operating at heater tube temperatures between 200 to 400 C. The resulting samples were fractionated to concentrate the soluble products and then analyzed using gas chromatographic and mass spectrometric techniques to quantify and identify the stable reaction intermediate and product specifically. Heteroatom addition showed that the major soluble products were always the same, with and without heteroatoms, but their distributions varied considerably.
Stability of drugs of abuse in urine samples stored at -20 degrees C.
Dugan, S; Bogema, S; Schwartz, R W; Lappas, N T
1994-01-01
Isolated studies of the stability of individual drugs of abuse have been reported. However, few have evaluated stability in frozen urine samples stored for 12 months. We have determined the stability of 11-nor-9-carboxy-delta 9-tetrahydrocannabinol (9-COOH-THC), amphetamine, methamphetamine, morphine, codeine, cocaine, benzoylecgonine, and phencyclidine in 236 physiological urine samples. Following the initial quantitative analysis, the samples were stored at -20 degrees C for 12 months and then reanalyzed. All drug concentrations were determined by gas chromatographic-mass spectrometric methods with cutoff concentrations of 5 ng/mL for 9-COOH-THC and phencyclidine and 100 ng/mL for each of the other drugs. The average change in the concentrations of these drugs following this long-term storage was not extensive except for an average change of -37% in cocaine concentrations.
Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry.
Santa, Tomofumi
2011-01-01
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 2010 John Wiley & Sons, Ltd.
Megutnishvili, Levan; Todua, Nino; Stein, Stephen; Mikaia, Anzor
2018-05-18
A GC-MS method is described for the characterization of thebaol, a component of opium poppy. The method includes preliminary sample derivatization to TMS, TBDMS, TFA, PFP and HFB substituted products. Fragmentation of resulting derivatives is unique under electron ionization, and proceeds via consecutive loss of two radicals that violate the "even-electron rule". Peaks of [M-2CH 3 ] +. and [M-C 4 H 9 -CH 3 ] +. ions show maximum intensities in the spectra of trimethyl- and tert-butyldimethylsilyl-thebaols. Elimination of perfluoroalkyl and methyl radicals from M +. is characteristic for TFA, PFP and HFB thebaols. The same fragmentation peculiarity is characteristic for derivatives prepared from related natural compounds containing vicinal 2-methoxyphenol moieties. The unique fragmentation of trialkylsilyl and perfluoroacyl derivatives of thebaol can be successfully used for thebaol determination within complex mixtures. This is part 4 from the series "Analytical derivatives in mass spectrometry", parts 1, 2 and 3 see [1-3]. Copyright © 2018 Elsevier B.V. All rights reserved.
Li, Peiwu; Zhang, Zhaowei; Hu, Xiaofeng; Zhang, Qi
2013-01-01
Mass spectrometric techniques are essential for advanced research in food safety and environmental monitoring. These fields are important for securing the health of humans and animals, and for ensuring environmental security. Mycotoxins, toxic secondary metabolites of filamentous fungi, are major contaminants of agricultural products, food and feed, biological samples, and the environment as a whole. Mycotoxins can cause cancers, nephritic and hepatic diseases, various hemorrhagic syndromes, and immune and neurological disorders. Mycotoxin-contaminated food and feed can provoke trade conflicts, resulting in massive economic losses. Risk assessment of mycotoxin contamination for humans and animals generally depends on clear identification and reliable quantitation in diversified matrices. Pioneering work on mycotoxin quantitation using mass spectrometry (MS) was performed in the early 1970s. Now, unambiguous confirmation and quantitation of mycotoxins can be readily achieved with a variety hyphenated techniques that combine chromatographic separation with MS, including liquid chromatography (LC) or gas chromatography (GC). With the advent of atmospheric pressure ionization, LC-MS has become a routine technique. Recently, the co-occurrence of multiple mycotoxins in the same sample has drawn an increasing amount of attention. Thus, modern analyses must be able to detect and quantitate multiple mycotoxins in a single run. Improvements in tandem MS techniques have been made to achieve this purpose. This review describes the advanced research that has been done regarding mycotoxin determination using hyphenated chromatographic-MS techniques, but is not a full-circle survey of all the literature published on this topic. The present work provides an overview of the various hyphenated chromatographic-MS-based strategies that have been applied to mycotoxin analysis, with a focus on recent developments. The use of chromatographic-MS to measure levels of mycotoxins, including aflatoxins, ochratoxins, patulin, trichothecenes, zearalenone, and fumonisins, is discussed in detail. Both free and masked mycotoxins are included in this review due to different methods of sample preparation. Techniques are described in terms of sample preparation, internal standards, LC/ultra performance LC (UPLC) optimization, and applications and survey. Several future hyphenated MS techniques are discussed as well, including multidimensional chromatography-MS, capillary electrophoresis-MS, and surface plasmon resonance array-MS. © 2013 Wiley Periodicals, Inc.
Hercegová, Andrea; Dömötörová, Milena; Kruzlicová, Dása; Matisová, Eva
2006-05-01
Four sample preparation techniques were compared for the ultratrace analysis of pesticide residues in baby food: (a) modified Schenck's method based on ACN extraction with SPE cleaning; (b) quick, easy, cheap, effective, rugged, and safe (QuEChERS) method based on ACN extraction and dispersive SPE; (c) modified QuEChERS method which utilizes column-based SPE instead of dispersive SPE; and (d) matrix solid phase dispersion (MSPD). The methods were combined with fast gas chromatographic-mass spectrometric analysis. The effectiveness of clean-up of the final extract was determined by comparison of the chromatograms obtained. Time consumption, laboriousness, demands on glassware and working place, and consumption of chemicals, especially solvents, increase in the following order QuEChERS < modified QuEChERS < MSPD < modified Schenck's method. All methods offer satisfactory analytical characteristics at the concentration levels of 5, 10, and 100 microg/kg in terms of recoveries and repeatability. Recoveries obtained for the modified QuEChERS method were lower than for the original QuEChERS. In general the best LOQs were obtained for the modified Schenck's method. Modified QuEChERS method provides 21-72% better LOQs than the original method.
van Stee, Leo L P; Brinkman, Udo A Th
2011-10-28
A method is presented to facilitate the non-target analysis of data obtained in temperature-programmed comprehensive two-dimensional (2D) gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-ToF-MS). One main difficulty of GC×GC data analysis is that each peak is usually modulated several times and therefore appears as a series of peaks (or peaklets) in the one-dimensionally recorded data. The proposed method, 2DAid, uses basic chromatographic laws to calculate the theoretical shape of a 2D peak (a cluster of peaklets originating from the same analyte) in order to define the area in which the peaklets of each individual compound can be expected to show up. Based on analyte-identity information obtained by means of mass spectral library searching, the individual peaklets are then combined into a single 2D peak. The method is applied, amongst others, to a complex mixture containing 362 analytes. It is demonstrated that the 2D peak shapes can be accurately predicted and that clustering and further processing can reduce the final peak list to a manageable size. Copyright © 2011 Elsevier B.V. All rights reserved.
Cossé, Allard A; Petroski, Richard J; Zilkowski, Bruce W; Vermillion, Karl; Lelito, Jonathan P; Cooperband, Miriam F; Gould, Juli R
2012-04-01
The braconid wasp, Spathius agrili, has been released in the U.S. as a biocontrol agent for the invasive emerald ash borer (Coleoptera: Buprestidae: Agrilus planipennis), a destructive pest of ash trees (Fraxinus spp.). We identified and synthesized seven male-specific volatile compounds. Three of these, dodecanal, (4R,11E)-tetradecen-4-olide, and (Z)-10-heptadecen-2-one, were the key behaviorally active components in flight tunnel bioassays. Male specificity was demonstrated by gas chromatographic comparison of male and female volatile emissions and whole body extracts. Identifications were aided by coupled gas chromatographic-mass spectrometric (GC-MS) analysis, microchemical reactions, NMR, chiral GC analysis, and GC and MS comparison with authentic standards. Both the racemic and chiral forms of the γ-lactone, as well as both E- and Z-isomers were synthesized. Flight tunnel behavioral tests showed positive male and female S. agrili responses to both natural pheromone and synthetic blends, with upwind flight and landing on the source. Large field-cage tests, using yellow sticky traps baited with pheromone, captured approximately 50% of the released male and female wasps in 24-h periods. The use of pheromone-baited traps in the field could simplify the current detection method for determining parasitoid establishment (i.e., laboriously felling and peeling ash trees for recovery of S. agrili from infested EAB larvae).
NASA Astrophysics Data System (ADS)
Vershinin, N. O.; Sokolova, I. V.; Tchaikovskaya, O. N.; Nevolina, K. A.
2015-11-01
The herbicide 2,4-dichlorophenoxyacetic acid was investigated in aqueous solution. A KrCl excilamp with an emission wavelength of 222 nm was used as radiation source. The direction of variation in the concentration of the toxicant during UV irradiation is discussed. The photodegradation constants are calculated. A chromatographic-mass spectrometric analysis of the photoproducts was undertaken.
Chen, Xiaoyan; Huang, Jia; Kong, Zhang; Zhong, Dafang
2005-03-25
A rapid and sensitive method for the simultaneous determination of paracetamol and guaifenesin in human plasma was developed and validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. After extracted from plasma samples by diethyl ether-dichloromethane (3:2, v/v), the analytes and internal standard osalmide were chromatographed on a C18 column. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method was linear in the concentration range of 0.05-20.0 microg/ml for paracetamol and 5.0-2000.0 ng/ml for guaifenesin. The intra- and inter-day precision was within 14% for both paracetamol and guaifenesin. The assay accuracy was within +/-2.4% for the analytes. This is the first assay method described for the simultaneous determination of paracetamol and guaifenesin in plasma using one chromatographic run. The method was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation, containing 650 mg paracetamol, 200 mg guaifenesin, 60 mg pseudoephedrine and 20 mg dextrorphan.
Emory, Joshua F.; Seserko, Lauren A.; Marzinke, Mark A.
2014-01-01
Background Maraviroc is a CCR5 antagonist that has been utilized as a viral entry inhibitor in the management of HIV-1. Current clinical trials are pursuing maraviroc drug efficacy in both oral and topical formulations. Therefore, in order to fully understand drug pharmacokinetics, a sensitive method is required to quantify plasma drug concentrations. Methods Maraviroc-spiked plasma was combined with acetonitrile containing an isotopically-labeled internal standard, and following protein precipitation, samples were evaporated to dryness and reconstituted for liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. Chromatographic separation was achieved on a Waters BEH C8, 50 × 2.1 mm UPLC column, with a 1.7 μm particle size and the eluent was analyzed using an API 4000 mass analyzer in selected reaction monitoring mode. The method was validated as per FDA Bioanalytical Method Validation guidelines. Results The analytical measuring range of the LC-MS/MS method is 0.5-1000 ng/ml. Calibration curves were generated using weighted 1/x2 quadratic regression. Inter-and intra-assay precision was ≤ 5.38% and ≤ 5.98%, respectively; inter-and intra-assay accuracy (%DEV) was ≤ 10.2% and ≤ 8.44%, respectively. Additional studies illustrated similar matrix effects between maraviroc and its internal standard, and that maraviroc is stable under a variety of conditions. Method comparison studies with a reference LC-MS/MS method show a slope of 0.948 with a Spearman coefficient of 0.98. Conclusions Based on the validation metrics, we have generated a sensitive and automated LC-MS/MS method for maraviroc quantification in human plasma. PMID:24561264
Trapp, Oliver
2010-02-12
Highly efficient and sophisticated separation techniques are available to analyze complex compound mixtures with superior sensitivities and selectivities often enhanced by a 2nd dimension, e.g. a separation technique or spectroscopic and spectrometric techniques. For enantioselective separations numerous chiral stationary phases (CSPs) exist to cover a broad range of chiral compounds. Despite these advances enantioselective separations can become very challenging for mixtures of stereolabile constitutional isomers, because the on-column interconversion can lead to completely overlapping peak profiles. Typically, multidimensional separation techniques, e.g. multidimensional GC (MDGC), using an achiral 1st separation dimension and transferring selected analytes to a chiral 2nd separation are the method of choice to approach such problems. However, this procedure is very time consuming and only predefined sections of peaks can be transferred by column switching to the second dimension. Here we demonstrate for stereolabile 1,2-dialkylated diaziridines a technique to experimentally deconvolute overlapping gas chromatographic elution profiles of constitutional isomers based on multiple-reaction-monitoring MS (MRM-MS). The here presented technique takes advantage of different fragmentation probabilities and pathways to isolate the elution profile of configurational isomers. Copyright 2009 Elsevier B.V. All rights reserved.
Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L
2010-02-15
Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.
Anderson, Duwayne M.; Biemann, K.; Orgel, Leslie E.; Oro, John; Owen, Timothy W.; Shulman, Garson P.; Toulmin, Priestley; Urey, H.C.
1972-01-01
An experiment centering around a mass spectrometer is described, which is aimed at the identification of organic substances present in the top 10 cm of the surface of Mars and an analysis of the atmosphere for major and minor constituents as well as isotopic abundances. In addition, an indication of the abundance of water in the surface and some information concerning the mineralogy can be obtained by monitoring the gases produced upon heating the soil sample.The organic material will simply be expelled by heating to 150°, 300°, and 500° into the carrier gas stream of a gas chromatograph interfaced to the mass spectrometer or by slowly heating the sample in direct communication with the spectrometer. It is planned to analyze a total of up to nine soil samples in order to study diurnal and seasonal variations. The system is designed to give useful data even for minor constituents if the total of organics should be as low as 5ppm. The spectrometer covers the mass range of 12–200 with adequate resolution.The results of these experiments, which are deliberately designed to cover a wide spectrum of possibilities independent of terrestrial models, are expected to produce a good picture of the planet's organic chemistry and its possible biological significance as well as allow conclusions regarding the history of the planet's atmosphere.
Hao, Chunyan; Zhao, Xiaoming; Morse, David; Yang, Paul; Taguchi, Vince; Morra, Franca
2013-08-23
Liquid chromatography tandem mass spectrometry (LC-MS/MS) determination of quaternary ammonium herbicides diquat (DQ) and paraquat (PQ) can be very challenging due to their complicated chromatographic and mass spectrometric behaviors. Various multiple reaction monitoring (MRM) transitions from radical cations M(+) and singly charged cations [M-H](+), have been reported for LC-MS/MS quantitation under different chromatographic and mass spectrometric conditions. However, interference peaks were observed for certain previously reported MRM transitions in our study. Using a Dionex Acclaim(®) reversed-phase and HILIC mixed-mode LC column, we evaluated the most sensitive MRM transitions from three types of quasi-molecular ions of DQ and PQ, elucidated the cross-interference phenomena, and demonstrated that the rarely mentioned MRM transitions from dications M(2+) offered the best selectivity for LC-MS/MS analysis. Experimental parameters, such as IonSpray (IS) voltage, source temperature, declustering potential (DP), column oven temperature, collision energy (CE), acid and salt concentrations in the mobile phases were also optimized and an uncommon electrospray ionization (ESI) capillary voltage of 1000V achieved the highest sensitivity. Employing the proposed dication transitions 92/84.5 for DQ and 93/171 for PQ, the direct aqueous injection LC-MS/MS method developed was able to provide a method detection limit (MDL) of 0.1μg/L for the determination of these two herbicides in drinking water. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Marsol-Vall, Alexis; Kortesniemi, Maaria Katariina; Karhu, Saila; Kallio, Heikki; Yang, Baoru
2018-06-25
The volatile profile of three blackcurrant (Ribes nigrum L.) cultivars grown in Finland and their response to growth latitude and weather conditions were studied over an eight-year period by headspace solid-phase microextraction (HS-SPME) followed by gas chromatographic-mass spectrometric (GC-MS) analysis. Monoterpene hydrocarbons and oxygenated monoterpenes were the major classes of volatiles. The cultivar 'Melalahti' presented lower content of volatiles compared with 'Ola' and 'Mortti', the two latter showing a very similar composition. Higher contents of volatiles were found in berries cultivated at higher latitude (66° 34' N) than in those from the southern location (60° 23' N). Among the meteorological variables, radiation and temperature during the last month before harvest were negatively linked with the volatile content. Storage time had a negative impact on the amount of blackcurrant volatiles.
Lukić, Igor; Horvat, Ivana
2017-03-01
To differentiate monovarietal wines made from native and introduced varieties in Istria (Croatia), samples of Malvazija istarska, Chardonnay and Muscat yellow from two harvest years (2013 and 2014) were subjected to headspace solid-phase microextraction and gas chromatographic/mass spectrometric analysis (HS-SPME-GC/MS) of volatile aroma compounds. Significant effects of variety and harvest year were determined, but their interaction complicated the differentiation. Particular compounds were consistent as markers of variety in both years: nerol for Malvazija, ethyl cinnamate and a tentatively identified isomer of dimethylbenzaldehyde for Chardonnay, and terpenes for Muscat yellow. Wines from 2013 contained higher concentrations of the majority of important volatiles. A 100% correct differentiation of Malvazija istarska and Chardonnay wines according to both variety and harvest year was achieved by stepwise linear discriminant analysis.
Farneti, Brian; Khomenko, Iuliia; Grisenti, Marcella; Ajelli, Matteo; Betta, Emanuela; Algarra, Alberto Alarcon; Cappellin, Luca; Aprea, Eugenio; Gasperi, Flavia; Biasioli, Franco; Giongo, Lara
2017-01-01
Blueberry (Vaccinium spp.) fruit consumption has increased over the last 5 years, becoming the second most important soft fruit species after strawberry. Despite the possible economic and sensory impact, the blueberry volatile organic compound (VOC) composition has been poorly investigated. Thus, the great impact of the aroma on fruit marketability stimulates the need to step forward in the understanding of this quality trait. Beside the strong effect of ripening, blueberry aroma profile also varies due to the broad genetic differences among Vaccinium species that have been differently introgressed in modern commercial cultivars through breeding activity. In the present study, divided into two different activities, the complexity of blueberry aroma was explored by an exhaustive untargeted VOC analysis, performed by two complementary methods: SPME-GC-MS (solid phase microextraction- gas chromatography-mass spectrometry) and PTR-ToF-MS (proton transfer reaction-time of flight-mass spectrometry). The first experiment was aimed at determining the VOC modifications during blueberry ripening for five commercially representative cultivars (“Biloxi,” “Brigitta Blue,” “Centurion,” “Chandler,” and “Ozark Blue”) harvested at four ripening stages (green, pink, ripe, and over-ripe) to outline VOCs dynamic during fruit development. The objective of the second experiment was to confirm the analytical capability of PTR-ToF-MS to profile blueberry genotypes and to identify the most characterizing VOCs. In this case, 11 accessions belonging to different Vaccinium species were employed: V. corymbosum L. (“Brigitta,” “Chandler,” “Liberty,” and “Ozark Blue”), V. virgatum Aiton (“Centurion,” “Powder Blue,” and “Sky Blue”), V. myrtillus L. (three wild genotypes of different mountain locations), and one accession of V. cylindraceum Smith. This comprehensive characterization of blueberry aroma allowed the identification of a wide pull of VOCs, for the most aldehydes, alcohols, terpenoids, and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma. PMID:28491071
Farneti, Brian; Khomenko, Iuliia; Grisenti, Marcella; Ajelli, Matteo; Betta, Emanuela; Algarra, Alberto Alarcon; Cappellin, Luca; Aprea, Eugenio; Gasperi, Flavia; Biasioli, Franco; Giongo, Lara
2017-01-01
Blueberry ( Vaccinium spp.) fruit consumption has increased over the last 5 years, becoming the second most important soft fruit species after strawberry. Despite the possible economic and sensory impact, the blueberry volatile organic compound (VOC) composition has been poorly investigated. Thus, the great impact of the aroma on fruit marketability stimulates the need to step forward in the understanding of this quality trait. Beside the strong effect of ripening, blueberry aroma profile also varies due to the broad genetic differences among Vaccinium species that have been differently introgressed in modern commercial cultivars through breeding activity. In the present study, divided into two different activities, the complexity of blueberry aroma was explored by an exhaustive untargeted VOC analysis, performed by two complementary methods: SPME-GC-MS (solid phase microextraction- gas chromatography-mass spectrometry) and PTR-ToF-MS (proton transfer reaction-time of flight-mass spectrometry). The first experiment was aimed at determining the VOC modifications during blueberry ripening for five commercially representative cultivars ("Biloxi," "Brigitta Blue," "Centurion," "Chandler," and "Ozark Blue") harvested at four ripening stages (green, pink, ripe, and over-ripe) to outline VOCs dynamic during fruit development. The objective of the second experiment was to confirm the analytical capability of PTR-ToF-MS to profile blueberry genotypes and to identify the most characterizing VOCs. In this case, 11 accessions belonging to different Vaccinium species were employed: V . corymbosum L. ("Brigitta," "Chandler," "Liberty," and "Ozark Blue"), V. virgatum Aiton ("Centurion," "Powder Blue," and "Sky Blue"), V. myrtillus L. (three wild genotypes of different mountain locations), and one accession of V. cylindraceum Smith. This comprehensive characterization of blueberry aroma allowed the identification of a wide pull of VOCs, for the most aldehydes, alcohols, terpenoids, and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma.
Hess, Cornelius; Sydow, Konrad; Kueting, Theresa; Kraemer, Michael; Maas, Alexandra
2018-02-01
The requirement for correct evaluation of forensic toxicological results in daily routine work and scientific studies is reliable analytical data based on validated methods. Validation of a method gives the analyst tools to estimate the efficacy and reliability of the analytical method. Without validation, data might be contested in court and lead to unjustified legal consequences for a defendant. Therefore, new analytical methods to be used in forensic toxicology require careful method development and validation of the final method. Until now, there are no publications on the validation of chromatographic mass spectrometric methods for the detection of endogenous substances although endogenous analytes can be important in Forensic Toxicology (alcohol consumption marker, congener alcohols, gamma hydroxy butyric acid, human insulin and C-peptide, creatinine, postmortal clinical parameters). For these analytes, conventional validation instructions cannot be followed completely. In this paper, important practical considerations in analytical method validation for endogenous substances will be discussed which may be used as guidance for scientists wishing to develop and validate analytical methods for analytes produced naturally in the human body. Especially the validation parameters calibration model, analytical limits, accuracy (bias and precision) and matrix effects and recovery have to be approached differently. Highest attention should be paid to selectivity experiments. Copyright © 2017 Elsevier B.V. All rights reserved.
Identification and Quantitative Measurements of Chemical Species by Mass Spectrometry
NASA Technical Reports Server (NTRS)
Zondlo, Mark A.; Bomse, David S.
2005-01-01
The development of a miniature gas chromatograph/mass spectrometer system for the measurement of chemical species of interest to combustion is described. The completed system is a fully-contained, automated instrument consisting of a sampling inlet, a small-scale gas chromatograph, a miniature, quadrupole mass spectrometer, vacuum pumps, and software. A pair of computer-driven valves controls the gas sampling and introduction to the chromatographic column. The column has a stainless steel exterior and a silica interior, and contains an adsorbent of that is used to separate organic species. The detection system is based on a quadrupole mass spectrometer consisting of a micropole array, electrometer, and a computer interface. The vacuum system has two miniature pumps to maintain the low pressure needed for the mass spectrometer. A laptop computer uses custom software to control the entire system and collect the data. In a laboratory demonstration, the system separated calibration mixtures containing 1000 ppm of alkanes and alkenes.
2015-06-07
Field-Portable Gas Chromatograph-Mass Spectrometer.” Forensic Toxicol, 2006, 24, 17-22. Smith, P. “Person-Portable Gas Chromatography : Rapid Temperature...bench-top Gas Chromatograph-Mass Spectrometer (GC-MS) system (ISQ). Nine sites were sampled and analyzed for compounds using Environmental Protection...extraction methods for Liquid Chromatography -MS (LC- MS). Additionally, TD is approximately 1000X more sensitive, requires minimal sample preparation
A tandem mass spectrometric method for singlet oxygen measurement.
Karonen, Maarit; Mattila, Heta; Huang, Ping; Mamedov, Fikret; Styring, Stenbjörn; Tyystjärvi, Esa
2014-01-01
Singlet oxygen, a harmful reactive oxygen species, can be quantified with the substance 2,2,6,6-tetramethylpiperidine (TEMP) that reacts with singlet oxygen, forming a stable nitroxyl radical (TEMPO). TEMPO has earlier been quantified with electron paramagnetic resonance (EPR) spectroscopy. In this study, we designed an ultra-high-performance liquid chromatographic-tandem mass spectrometric (UHPLC-ESI-MS/MS) quantification method for TEMPO and showed that the method based on multiple reaction monitoring (MRM) can be used for the measurements of singlet oxygen from both nonbiological and biological samples. Results obtained with both UHPLC-ESI-MS/MS and EPR methods suggest that plant thylakoid membranes produce 3.7 × 10(-7) molecules of singlet oxygen per chlorophyll molecule in a second when illuminated with the photosynthetic photon flux density of 2000 μmol m(-2 ) s(-1). © 2014 The American Society of Photobiology.
Ch, Muhammad Ishtiaq; Wen, Yang F; Cheng, YiYu
2007-01-01
This paper describes a simple and novel on-column derivatization procedure used with gas chromatography/mass spectrometry (GC/MS) for the analysis of essential oil of Houttuynia cordata Thunb (HCT), a traditional Chinese medicine. In the procedure, the essential oil was obtained by hydrodistillation, and the fatty acid components were derivatized with tetramethylammonium acetate (TMAA) at 250 degrees C and identified by GC/MS. Methylation improved the determination of both the fatty acids and the other components in the essential oil of HCT. To obtain optimum methylation conditions, several important factors were investigated with pentadecane as the internal standard and a GC inlet temperature of 250 degres C. Tetramethylammonium hydroxide (TMAH) and TMAA were compared as the derivatization agent, and a 2:1 ratio of TMAA to capric acid was evaluated. Fatty acid methyl esters produced good chromatographic peak shapes and did not interfere with the determination of dodecanal and caryophyllene. TMAA is a neutral methylation reagent, and it yielded no side reactions during derivatization. It was found that the fatty acid content of the essential oil was about 81%; among the methylated fatty acids found were capric acid, methyl (43.66%), methyl laurate (16.15%), methyl hexadecanoate (9.27%), undecanoic acid, methyl (5.62%), methyl oleate (1.98%), and methyl linoleate (1.40%). Other major constituents were (-)-beta-pinene (1.02%), beta-myrcene (1.62%), 1-terpinen-4-ol (1.59%), decanal (1.49%), and 2-undecanone (1.47%). The results obtained demonstrated good efficiency for the procedure. Pure chromatograms allowed quantitation, which was obtained by total volume integration. The on-column derivatization procedure was simple to perform, and it improved the sensitivity, the peak resolution, and the selectivity of the GC/MS determination.
Cheng, Ting; Nebel, Oliver; Sossi, Paolo A.; Chen, Fukun
2014-01-01
A combined procedure for separating Fe and Hf from a single rock digestion is presented. In a two-stage chromatographic extraction process, a purified Fe fraction is first quantitatively separated from the rock matrix using AG-MP-1M resin in HCl. Hafnium is subsequently isolated using a modified version of a commonly applied method using Eichrom LN-Spec resin. Our combined method includes:•Purification of Fe from the rock matrix using HCl, ready for mass spectrometric analysis.•Direct loading of the matrix onto the resin that is used for Hf purification.•Collection of a Fe-free Hf fraction. PMID:26150946
Elemental speciation for chromium in chromium picolinate products
NASA Astrophysics Data System (ADS)
Ding, Hong; Olson, Lisa K.; Caruso, Joseph A.
1996-12-01
Chromium picolinate products have been examined for different forms of chromium, using chromatographic separation and inductively coupled plasma mass spectrometric detection. The brands we evaluated contained no detectable amount of elemental chromium(VI), the toxic form. Since chromium picolinate might have other chromium forms as impurities, different products may contain different forms of chromium species. Compared with ion-exchange, reversed-phase chromatography showed excellent chromium recovery based on the amount stated on the product label.
Pérez, Hermes Licea; Osterman-Golkar, Siv
2003-08-01
A sensitive analytical method for the analysis of acrylamide and other electrophilic agents in water has been developed. The amino acid L-valine served as a nucleophilic trapping agent. The method was applied to the analysis of acrylamide in 0.2-1 mL samples of drinking water or Millipore-filtered water, brewed coffee, or water extracts of snuff. The reaction product, N-(2-carbamoylethyl)valine, was incubated with pentafluorophenyl isothiocyanate to give a pentafluorophenylthiohydantoin (PFPTH) derivative. This derivative was extracted with diethyl ether, separated from excess reagent and impurities by a simple extraction procedure, and analyzed by gas chromatography-tandem mass spectrometry. (2H3)Acrylamide, added before the reaction with L-valine, was used as internal standard. Acrylamide and the related compound, N-methylolacrylamide, gave the same PFPTH derivative. The concentrations of acrylamides were < or = 0.4 nmol L(-1) (< or = 0.03 microg acrylamide L(-1)) in water, 200 to 350 nmol L(-1) in brewed coffee, and 10 to 34 nmol g(-1) snuff in portion bags, respectively. The precision (the coefficient of variation was 5%) and accuracy of the method were good. The detection limit was considerably lower than that of previously published methods for the analysis of acrylamide.
Svagera, Zdeněk; Hanzlíková, Dagmar; Simek, Petr; Hušek, Petr
2012-03-01
Four disulfide-reducing agents, dithiothreitol (DTT), 2,3-dimercaptopropanesulfonate (DMPS), and the newly tested 2-mercaptoethanesulfonate (MESNA) and Tris(hydroxypropyl)phosphine (THP), were investigated in detail for release of sulfur amino acids in human plasma. After protein precipitation with trichloroacetic acid (TCA), the plasma supernatant was treated with methyl, ethyl, or propyl chloroformate via the well-proven derivatization-extraction technique and the products were subjected to gas chromatographic-mass spectrometric (GC-MS) analysis. All the tested agents proved to be rapid and effective reducing agents for the assay of plasma thiols. When compared with DTT, the novel reducing agents DMPS, MESNA, and THP provided much cleaner extracts and improved analytical performance. Quantification of homocysteine, cysteine, and methionine was performed using their deuterated analogues, whereas other analytes were quantified by means of 4-chlorophenylalanine. Precise and reliable assay of all examined analytes was achieved, irrespective of the chloroformate reagent used. Average relative standard deviations at each analyte level were ≤6%, quantification limits were 0.1-0.2 μmol L(-1), recoveries were 94-121%, and linearity was over three orders of magnitude (r(2) equal to 0.997-0.998). Validation performed with the THP agent and propyl chloroformate derivatization demonstrated the robustness and reliability of this simple sample-preparation methodology.
Satpathy, Gouri; Tyagi, Yogesh Kumar; Gupta, Rajinder Kumar
2011-08-01
A rapid, effective and ecofriendly method for sensitive screening and quantification of 72 pesticides residue in fruits and vegetables, by microwave-assisted extraction (MAE) followed by dispersive solid-phase extraction (d-SPE), retention time locked (RTL) capillary gas-chromatographic separation in trace ion mode mass spectrometric determination has been validated as per ISO/IEC: 17025:2005. Identification and reporting with total and extracted ion chromatograms were facilitated to a great extent by Deconvolution reporting software (DRS). For all compounds LOD were 0.002-0.02mg/kg and LOQ were 0.025-0.100mg/kg. Correlation coefficients of the calibration curves in the range of 0.025-0.50mg/kg were >0.993. To validate matrix effects repeatability, reproducibility, recovery and overall uncertainty were calculated for the 35 matrices at 0.025, 0.050 and 0.100mg/kg. Recovery ranged between 72% and 114% with RSD of <20% for repeatability and intermediate precision. The reproducibility of the method was evaluated by an inter laboratory participation and Z score obtained within ±2. Copyright © 2011 Elsevier Ltd. All rights reserved.
Lerch, Oliver; Temme, Oliver; Daldrup, Thomas
2014-07-01
The analysis of opioids, cocaine, and metabolites from blood serum is a routine task in forensic laboratories. Commonly, the employed methods include many manual or partly automated steps like protein precipitation, dilution, solid phase extraction, evaporation, and derivatization preceding a gas chromatography (GC)/mass spectrometry (MS) or liquid chromatography (LC)/MS analysis. In this study, a comprehensively automated method was developed from a validated, partly automated routine method. This was possible by replicating method parameters on the automated system. Only marginal optimization of parameters was necessary. The automation relying on an x-y-z robot after manual protein precipitation includes the solid phase extraction, evaporation of the eluate, derivatization (silylation with N-methyl-N-trimethylsilyltrifluoroacetamide, MSTFA), and injection into a GC/MS. A quantitative analysis of almost 170 authentic serum samples and more than 50 authentic samples of other matrices like urine, different tissues, and heart blood on cocaine, benzoylecgonine, methadone, morphine, codeine, 6-monoacetylmorphine, dihydrocodeine, and 7-aminoflunitrazepam was conducted with both methods proving that the analytical results are equivalent even near the limits of quantification (low ng/ml range). To our best knowledge, this application is the first one reported in the literature employing this sample preparation system.
Wolrath, H; Forsum, U; Larsson, P G; Borén, H
2001-11-01
The presence of various amines in vaginal fluid from women with malodorous vaginal discharge has been reported before. The investigations have used several techniques to identify the amines. However, an optimized quantification, together with a sensitive analysis method in connection with a diagnostic procedure for vaginal discharge, including the syndrome of bacterial vaginosis, as defined by the accepted "gold standard," has not been done before. We now report a sensitive gas chromatographic and mass spectrometric method for identifying the amines isobutylamine, phenethylamine, putrescine, cadaverine, and tyramine in vaginal fluid. We used weighted samples of vaginal fluid to obtain a correct quantification. In addition, a proper diagnosis was obtained using Gram-stained smears of the vaginal fluid that were Nugent scored according to the method of Nugent et al. (R. P. Nugent et al., J. Clin. Microbiol., 29:297-301, 1991). We found that putrescine, cadaverine, and tyramine occurred in high concentrations in vaginal fluid from 24 women with Nugent scores between 7 and 10. These amines either were not found or were found only in very low concentrations in vaginal fluid from women with Nugent scores of 0 to 3. There is a strong correlation between bacterial vaginosis and the presence of putrescine, cadaverine, and tyramine in high concentrations in vaginal fluid.
Antonious, George F; Turley, Eric T; Abubakari, Mutari; Snyder, John C
2017-04-03
The persistence and fate of chlorpyrifos and its two metabolites, chlorpyrifos-oxon and the 3, 5, 6-trichloro-2-pyridinol (TCP) break-down product were investigated on kale and collard leaves under field conditions. A simultaneous extraction and quantification procedure was developed for chrorpyrifos and its two main metabolites. Residues of chlorpyrifos, chlorpyrifos oxon, and TCP were determined using a gas chromatograph (GC) equipped with an electron capture detector (GC/ECD). Chlorpyrifos metabolites were detectable up to 23 days following application. Residues were confirmed using a GC equipped with a mass selective detector (GC/MSD) in total ion mode. Initial residues of chlorpyrifos were greater on collard (14.5 µg g -1 ) than kale (8.2 µg g -1 ) corresponding to half-lives (T 1/2 ) values of 7.4 and 2.2 days, respectively. TCP, the hydrolysis product, was more persistent on collards with an estimated T 1/2 of 6.5 days compared to kale (T 1/2 of 1.9 days).
Electrospray Modifications for Advancing Mass Spectrometric Analysis
Meher, Anil Kumar; Chen, Yu-Chie
2017-01-01
Generation of analyte ions in gas phase is a primary requirement for mass spectrometric analysis. One of the ionization techniques that can be used to generate gas phase ions is electrospray ionization (ESI). ESI is a soft ionization method that can be used to analyze analytes ranging from small organics to large biomolecules. Numerous ionization techniques derived from ESI have been reported in the past two decades. These ion sources are aimed to achieve simplicity and ease of operation. Many of these ionization methods allow the flexibility for elimination or minimization of sample preparation steps prior to mass spectrometric analysis. Such ion sources have opened up new possibilities for taking scientific challenges, which might be limited by the conventional ESI technique. Thus, the number of ESI variants continues to increase. This review provides an overview of ionization techniques based on the use of electrospray reported in recent years. Also, a brief discussion on the instrumentation, underlying processes, and selected applications is also presented. PMID:28573082
Impens, S; De Wasch, K; De Brabander, H
2001-01-01
Helium is considered to be the ideal carrier gas for gas chromatography/mass spectrometry (GC/MS) in general, and for use with an ion trap in particular. Helium is an inert gas, can be used without special precautions for security and, moreover, it is needed as a damping gas in the trap. A disadvantage of helium is the high viscosity resulting in long GC run times. In this work hydrogen was tested as an alternative carrier gas for GC in performing GC/MS analyses. A hydrogen generator was used as a safe source of hydrogen gas. It is demonstrated that hydrogen can be used as a carrier gas for the gas chromatograph in combination with helium as make-up gas for the trap. The analysis time was thus shortened and the chromatographic performance was optimized. Although hydrogen has proven useful as a carrier gas in gas chromatography coupled to standard detectors such as ECD or FID, its use is not mentioned extensively in the literature concerning gas chromatography-ion trap mass spectrometry. However, it is worth considering as a possibility because of its chromatographic advantages and its advantageous price when using a hydrogen generator. Copyright 2001 John Wiley & Sons, Ltd.
This research evaluates a recently developed comprehensive 2-D GC coupled with a time-of-flight (TOF) mass spectrometer for the potential separation of 209 PCB congeners, using a sequence of 1-D and 2-D chromatographic modes. In two consecutive chromatographic runs, using a 40 m,...
Charles, Laurence; Laure, Frédéric; Raharivelomanana, Phila; Bianchini, Jean-Pierre
2005-01-01
A novel interface that allows normal-phase liquid chromatography to be coupled with electrospray ionization (ESI) is reported. A make-up solution of 60 mM ammonium acetate in methanol, infused at a 5 microl min(-1) flow-rate at the tip of the electrospray probe, provides a sheath liquid which is poorly miscible with the chromatographic effluent, but promotes efficient ionization of the targeted analytes. Protonated molecules generated in the ESI source were subjected to tandem mass spectrometric experiments in a triple-quadrupole mass spectrometer. The main fragmentation reactions were characterized for each analyte and specific mass spectral transitions were used to acquire chromatographic data in the multiple reaction monitoring detection mode. Results obtained during optimization of the sheath liquid composition and flow-rate suggest that the electrospray process was mainly under the control of the make-up solution, and that it forms an external charged layer around a neutral chromatographic mobile phase core. This sheath liquid interface was implemented for the analysis of some neoflavonoid compounds and its performance was evaluated. Limits of detection were established for calophillolide, inophyllum B, inophyllum P and inophyllum C at 100, 25, 15 and 100 ng ml(-1), respectively.
Bankefors, Johan; Nord, Lars I; Kenne, Lennart
2010-02-01
A method for separation and detection of major and minor components in complex mixtures has been developed, utilising two-dimensional high-performance liquid chromatography (2D-HPLC) combined with electrospray ionisation ion-trap multiple-stage mass spectrometry (ESI-ITMS(n)). Chromatographic conditions were matched with mass spectrometric detection to maximise the number of components that could be separated. The described procedure has proven useful to discern several hundreds of saponin components when applied to Quillaja saponaria Molina bark extracts. The discrimination of each saponin component relies on the fact that three coordinates (x, y, z) for each component can be derived from the retention time of the two chromatographic steps (x, y) and the m/z-values from the multiple-stage mass spectrometry (z(n), n=1, 2, ...). Thus an improved graphical representation was obtained by combining retention times from the two-stage separation with +MS(1) (z(1)) and the additional structural information from the second mass stage +MS(2) (z(2), z(3)) corresponding to the main fragment ions. By this approach three-dimensional plots can be made that reveal both the chromatographic and structural properties of a specific mixture which can be useful in fingerprinting of complex mixtures. 2009 Elsevier B.V. All rights reserved.
Kabytaev, Kuanysh; Durairaj, Anita; Shin, Dmitriy; Rohlfing, Curt L; Connolly, Shawn; Little, Randie R; Stoyanov, Alexander V
2016-02-01
A liquid chromatography with mass spectrometry on-line platform that includes the orthogonal techniques of ion exchange and reversed phase chromatography is applied for C-peptide analysis. Additional improvement is achieved by the subsequent application of cation- and anion-exchange purification steps that allow for isolating components that have their isoelectric points in a narrow pH range before final reversed-phase mass spectrometry analysis. The utility of this approach for isolating fractions in the desired "pI window" for profiling complex mixtures is discussed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Abushareeda, Wadha; Lyris, Emmanouil; Kraiem, Suhail; Wahaibi, Aisha Al; Alyazidi, Sameera; Dbes, Najib; Lommen, Arjen; Nielen, Michel; Horvatovich, Peter L; Alsayrafi, Mohammed; Georgakopoulos, Costas
2017-09-15
This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World Antidoping Agency (WADA) enlists AAS as prohibited doping agents in sports, and our method has been developed to comply with the qualitative specifications of WADA to be applied for the detection of sports antidoping prohibited substances, mainly for AAS. The method also comprises of the quantitative analysis of the WADA's Athlete Biological Passport (ABP) endogenous steroidal parameters. The applied preparation of urine samples includes enzymatic hydrolysis for the cleavage of the Phase II glucuronide conjugates, generic liquid-liquid extraction and trimethylsilyl (TMS) derivatization steps. Tandem mass spectrometry (MS/MS) acquisition was applied on few selected ions to enhance the specificity and sensitivity of GC/TOF signal of few compounds. The full scan high resolution acquisition of analytical signal, for known and unknown TMS derivatives of AAS provides the antidoping system with a new analytical tool for the detection designer drugs and novel metabolites, which prolongs the AAS detection, after electronic data files' reprocessing. The current method is complementary to the respective liquid chromatography coupled to mass spectrometry (LC/MS) methodology widely used to detect prohibited molecules in sport, which cannot be efficiently ionized with atmospheric pressure ionization interface. Copyright © 2017 Elsevier B.V. All rights reserved.
A Portable and Autonomous Mass Spectrometric System for On-Site Environmental Gas Analysis.
Brennwald, Matthias S; Schmidt, Mark; Oser, Julian; Kipfer, Rolf
2016-12-20
We developed a portable mass spectrometric system ("miniRuedi") for quantificaton of the partial pressures of He, Ne (in dry gas), Ar, Kr, N 2 , O 2 , CO 2 , and CH 4 in gaseous and aqueous matrices in environmental systems with an analytical uncertainty of 1-3%. The miniRuedi does not require any purification or other preparation of the sampled gases and therefore allows maintenance-free and autonomous operation. The apparatus is most suitable for on-site gas analysis during field work and at remote locations due to its small size (60 cm × 40 cm × 14 cm), low weight (13 kg), and low power consumption (50 W). The gases are continuously sampled and transferred through a capillary pressure reduction system into a vacuum chamber, where they are analyzed using a quadrupole mass spectrometer with a time resolution of ≲1 min. The low gas consumption rate (<0.1 mL/min) minimizes interference with the natural mass balance of gases in environmental systems, and allows the unbiased quantification of dissolved-gas concentrations in water by gas/water equilibration using membrane contractors (gas-equilibrium membrane-inlet mass spectrometry, GE-MIMS). The performance of the miniRuedi is demonstrated in laboratory and field tests, and its utility is illustrated in field applications related to soil-gas formation, lake/atmosphere gas exchange, and seafloor gas emanations.
Sajewicz, Mieczysław; Gontarska, Monika; Kronenbach, Dorota; Berry, Etienne; Kowalska, Teresa
2012-03-01
In our earlier studies, a spontaneous chiral conversion of the selected low-molecular-weight carboxylic acids (i.e., amino acids, hydroxy acids, and profen drugs) dissolved in aqueous ethanol medium, running in vitro was described. Then it became clear that this spontaneous chiral conversion is accompanied by the spontaneous condensation of the discussed compounds. With several acids, it was established that this condensation is also oscillatory in nature. The theoretical models were developed aiming to give a rough explanation of the observed non-linear processes. In this paper, the results of these studies on the dynamics of condensation with S(+)-ketoprofen, a very popular profen drug, when stored for certain amount of time dissolved in a non-aqueous medium (i.e., acetonitrile) is presented. These investigations were carried out with the aid of two independent high-performance liquid chromatographic systems with the diode array detection and of a third high-performance liquid chromatographic system equipped with mass spectrometric detection. In one cycle of chromatographic measurements, it was possible to monitor condensation of S(+)-ketoprofen in 25-min intervals for 30 h, thus obtaining kinetic information on the progress of this process. Mass spectrometric detection confirmed the presence of new species in the stored solution with molecular weights much higher than that of S(+)-ketoprofen, which can be attributed to the condensation products. The obtained data show that condensation of S(+)-ketoprofen dissolved in acetonitrile progresses in a rapid manner, and that the observed oscillatory concentration changes with S(+)-ketoprofen and with the main condensation product characterize with an irregularity and shallow amplitudes. A theoretical model was referenced that jointly describes the oscillatory chiral conversion and the oscillatory condensation with the low-molecular-weight chiral carboxylic acids.
A Gas Chromatographic System for the Detection of Ethylene Gas Using Ambient Air as a Carrier Gas.
Zaidi, Nayyer Abbas; Tahir, Muhammad Waseem; Vellekoop, Michael J; Lang, Walter
2017-10-07
Ethylene gas is a naturally occurring gas that has an influence on the shelf life of fruit during their transportation in cargo ships. An unintentional exposure of ethylene gas during transportation results in a loss of fruit. A gas chromatographic system is presented here for the detection of ethylene gas. The gas chromatographic system was assembled using a preconcentrator, a printed 3D printed gas chromatographic column, a humidity sensor, solenoid valves, and an electrochemical ethylene gas sensor. Ambient air was used as a carrier gas in the gas chromatographic system. The flow rate was fixed to 10 sccm. It was generated through a mini-pump connected in series with a mass flow controller. The metal oxide gas sensor is discussed with its limitation in ambient air. The results show the chromatogram obtained from metal oxide gas sensor has low stability, drifts, and has uncertain peaks, while the chromatogram from the electrochemical sensor is stable and precise. Furthermore, ethylene gas measurements at higher ppb concentration and at lower ppb concentration were demonstrated with the electrochemical ethylene gas sensor. The system separates ethylene gas and humidity. The chromatograms obtained from the system are stable, and the results are 1.2% repeatable in five similar measurements. The statistical calculation of the gas chromatographic system shows that a concentration of 2.3 ppb of ethylene gas can be detected through this system.
Flight contaminant trace analyser. Phase 1: Chromatographic input system
NASA Technical Reports Server (NTRS)
Zlatkis, A.
1976-01-01
The purpose of this investigation was to develop two chromatographic columns which would enable a mass spectral identification of 40 specified compounds. The columns are for use in a toxic gas analyzer, which incorporates an automated gas chromatograph-mass spectrometer. Different types of stationary phases were investigated. The columns used were of the open tubular capillary type and were made of nickel. Limitations of initial and final temperature of operation led to final development of a column which could resolve most of the compounds required. The few unresolved components are capable of resolution and identification by the mass spectrometer. The columns (182m Ni x 0.8m 0.D x 0.5mm I.D) coated with Witconal La 23, yielded in excess of 200,000 theoretical plates and completed the analysis in less than 90 minutes using a carrier gas flow rate of 4 cc/min hydrogen.
NASA Astrophysics Data System (ADS)
Obersteiner, F.; Bönisch, H.; Engel, A.
2016-01-01
We present the characterization and application of a new gas chromatography time-of-flight mass spectrometry instrument (GC-TOFMS) for the quantitative analysis of halocarbons in air samples. The setup comprises three fundamental enhancements compared to our earlier work (Hoker et al., 2015): (1) full automation, (2) a mass resolving power R = m/Δm of the TOFMS (Tofwerk AG, Switzerland) increased up to 4000 and (3) a fully accessible data format of the mass spectrometric data. Automation in combination with the accessible data allowed an in-depth characterization of the instrument. Mass accuracy was found to be approximately 5 ppm in mean after automatic recalibration of the mass axis in each measurement. A TOFMS configuration giving R = 3500 was chosen to provide an R-to-sensitivity ratio suitable for our purpose. Calculated detection limits are as low as a few femtograms by means of the accurate mass information. The precision for substance quantification was 0.15 % at the best for an individual measurement and in general mainly determined by the signal-to-noise ratio of the chromatographic peak. Detector non-linearity was found to be insignificant up to a mixing ratio of roughly 150 ppt at 0.5 L sampled volume. At higher concentrations, non-linearities of a few percent were observed (precision level: 0.2 %) but could be attributed to a potential source within the detection system. A straightforward correction for those non-linearities was applied in data processing, again by exploiting the accurate mass information. Based on the overall characterization results, the GC-TOFMS instrument was found to be very well suited for the task of quantitative halocarbon trace gas observation and a big step forward compared to scanning, quadrupole MS with low mass resolving power and a TOFMS technique reported to be non-linear and restricted by a small dynamical range.
A Gas Chromatograph/Mass Spectrometer System for UltraLow-Emission Combustor Exhaust Studies
NASA Technical Reports Server (NTRS)
Brabbs, Theodore A.; Wey, Chowen Chou
1996-01-01
A gas chromatograph (GC)/mass spectrometer (MS) system that allows the speciation of unburnt hydrocarbons in the combustor exhaust has been developed at the NASA Lewis Research Center. Combustion gas samples are withdrawn through a water-cooled sampling probe which, when not in use, is protected from contamination by a high-pressure nitrogen purge. The sample line and its connecting lines, filters, and valves are all ultraclean and are heated to avoid condensation. The system has resolution to the parts-per-billion (ppb) level.
NASA Astrophysics Data System (ADS)
Hofer, L.; Lasi, D.; Tulej, M.; Wurz, P.; Cabane, M.; Cosica, D.; Gerasimov, M.; Rodinov, D.
2013-09-01
In preparation for the Russian Luna-Glob and Luna-Resurs missions we combined our compact time-offlight mass spectrometer (TOF-MS) with a chemical pre-separation of the species by gas chromatography (GC). Combined measurements with both instruments were successfully performed with the laboratory prototype of the mass spectrometer and a flight-like gas chromatograph. Due to its capability to record mass spectra over the full mass range at once with high sensitivity and a dynamic range of up to 106 within 1s, the TOF-MS system is a valuable extension of the GC analysis. The combined GC-MS complex is able to detect concentrations of volatile species in the sample of about 2·10^-9 by mass.
Ashraf-Khorassani, M; Isaac, G; Rainville, P; Fountain, K; Taylor, L T
2015-08-01
Most lipids are best characterized by their fatty acids which may differ in (a) chain length, (b) degree of unsaturation, (c) configuration and position of the double bonds, and (d) the presence of other functionalities. Thus, a fast, simple, and quantitative analytical technique to determine naturally occurring free fatty acids (FFA) in different samples is very important. Just as for saponified acylglycerols, the determination of FFA's has generally been carried out by high resolution gas chromatography (HRGC). The use of an open tubular capillary column coupled with a flame ionization or mass spectrometric detector provides for both high resolution and quantification of FFA's but only after conversion of all free fatty acids to fatty acid methyl esters (FAME) or pentafluorobenzyl esters. Unfortunately, volatilization of labile ester derivatives of mono- and poly-unsaturated FFA's can cause both thermal degradation and isomerization of the fatty acid during HRGC. The employment of a second generation instrument (here referred to as UltraHigh Performance Supercritical Fluid Chromatograph, UHPSFC) with high precision for modified flow and repeated back pressure adjustment in conjunction with sub-2μm various bonded silica particles (coupled with evaporative light scattering, ELSD, and mass spectrometric, MS, detection) for separation and detection of the following mixtures is described: (a) 31 free fatty acids, (b) isomeric FFA's, and (c) lipophilic materials in two real world fish oil samples. Limits of detection for FFA's via UHPSFC/MS and UHPSFC/ELSD versus detection of FAME's via HRGC/MS are quantitatively compared. Copyright © 2015 Elsevier B.V. All rights reserved.
Microbial transformation of nitroaromatic compounds in sewage effluent.
Hallas, L E; Alexander, M
1983-04-01
The transformation of mono- and dinitroaromatic compounds was measured in sewage effluent maintained under aerobic or anaerobic conditions. Most of the nitrobenzene, 3- and 4-nitrobenzoic acids, and 3- and 4-nitrotoluenes and much of the 1,2- and 1,3-dinitrobenzenes disappeared both in the presence and absence of oxygen. Under anaerobiosis, 2,6-dinitrotoluene and 3,5-dinitrobenzoic acid disappeared slowly, but no loss was evident in 28 days in aerated sewage. Aromatic amines did not accumulate during the aerobic decomposition of the mononitro compounds. They did appear in nonsterile, but not in sterile, sewage incubated aerobically with the dinitro compounds and anaerobically with all the chemicals. Analysis by gas chromatography and combined gas chromatography-mass spectrometry showed that aniline was formed from nitrobenzene, toluidine was formed from 3- and 4-nitrotoluenes, and aminobenzoic acid was formed from 3- and 4-nitrobenzoic acids under anaerobiosis, and that nitroaniline was formed from 1,2- and 1,3-dinitrobenzenes, aminonitrotoluene resulted from 2,6-dinitrotoluene, and aminonitrobenzoic acid was a product of 3,5-dinitrobenzoic acid under both conditions. The isomeric forms of the metabolites were not established. Aniline, 4-toluidine, and 4-aminobenzoic acid added to sewage disappeared from aerated nonsterile, but not from sterile, sewage or sewage in the absence of oxygen. 2-Nitroaniline, 2-amino-3-nitrotoluene, and 2-amino-5-nitrobenzoic acid added to sewage persisted for at least 60 days in aerobic or anaerobic conditions. Gas chromatographic and gas chromatographic-mass spectrometric analyses demonstrated that acetanilide and 2-methylquinoline were formed from aniline, 4-methylformanilide and 4-methylacetanilide were formed from 4-toluidine, 2-methylbenzimidazole was a product of 2-nitroaniline, and unidentified benzimidazoles were formed from 2-amino-3-nitrotoluene in the absence of oxygen, and that 2-nitroacetanilide and 2-methyl-6-nitroacetanilide were formed from 2-nitroaniline and 2-amino-3-nitrotoluene, respectively, in the presence or absence of oxygen. It is suggested that the transformations of widely used nitroaromatic compounds should be further studied because of the persistence and possible toxicity of products of their metabolism.
Microbial Transformation of Nitroaromatic Compounds in Sewage Effluent
Hallas, Laurence E.; Alexander, Martin
1983-01-01
The transformation of mono- and dinitroaromatic compounds was measured in sewage effluent maintained under aerobic or anaerobic conditions. Most of the nitrobenzene, 3- and 4-nitrobenzoic acids, and 3- and 4-nitrotoluenes and much of the 1,2- and 1,3-dinitrobenzenes disappeared both in the presence and absence of oxygen. Under anaerobiosis, 2,6-dinitrotoluene and 3,5-dinitrobenzoic acid disappeared slowly, but no loss was evident in 28 days in aerated sewage. Aromatic amines did not accumulate during the aerobic decomposition of the mononitro compounds. They did appear in nonsterile, but not in sterile, sewage incubated aerobically with the dinitro compounds and anaerobically with all the chemicals. Analysis by gas chromatography and combined gas chromatography-mass spectrometry showed that aniline was formed from nitrobenzene, toluidine was formed from 3- and 4-nitrotoluenes, and aminobenzoic acid was formed from 3- and 4-nitrobenzoic acids under anaerobiosis, and that nitroaniline was formed from 1,2- and 1,3-dinitrobenzenes, aminonitrotoluene resulted from 2,6-dinitrotoluene, and aminonitrobenzoic acid was a product of 3,5-dinitrobenzoic acid under both conditions. The isomeric forms of the metabolites were not established. Aniline, 4-toluidine, and 4-aminobenzoic acid added to sewage disappeared from aerated nonsterile, but not from sterile, sewage or sewage in the absence of oxygen. 2-Nitroaniline, 2-amino-3-nitrotoluene, and 2-amino-5-nitrobenzoic acid added to sewage persisted for at least 60 days in aerobic or anaerobic conditions. Gas chromatographic and gas chromatographic-mass spectrometric analyses demonstrated that acetanilide and 2-methylquinoline were formed from aniline, 4-methylformanilide and 4-methylacetanilide were formed from 4-toluidine, 2-methylbenzimidazole was a product of 2-nitroaniline, and unidentified benzimidazoles were formed from 2-amino-3-nitrotoluene in the absence of oxygen, and that 2-nitroacetanilide and 2-methyl-6-nitroacetanilide were formed from 2-nitroaniline and 2-amino-3-nitrotoluene, respectively, in the presence or absence of oxygen. It is suggested that the transformations of widely used nitroaromatic compounds should be further studied because of the persistence and possible toxicity of products of their metabolism. PMID:6859845
A Gas Chromatographic System for the Detection of Ethylene Gas Using Ambient Air as a Carrier Gas
Zaidi, Nayyer Abbas; Tahir, Muhammad Waseem; Vellekoop, Michael J.; Lang, Walter
2017-01-01
Ethylene gas is a naturally occurring gas that has an influence on the shelf life of fruit during their transportation in cargo ships. An unintentional exposure of ethylene gas during transportation results in a loss of fruit. A gas chromatographic system is presented here for the detection of ethylene gas. The gas chromatographic system was assembled using a preconcentrator, a printed 3D printed gas chromatographic column, a humidity sensor, solenoid valves, and an electrochemical ethylene gas sensor. Ambient air was used as a carrier gas in the gas chromatographic system. The flow rate was fixed to 10 sccm. It was generated through a mini-pump connected in series with a mass flow controller. The metal oxide gas sensor is discussed with its limitation in ambient air. The results show the chromatogram obtained from metal oxide gas sensor has low stability, drifts, and has uncertain peaks, while the chromatogram from the electrochemical sensor is stable and precise. Furthermore, ethylene gas measurements at higher ppb concentration and at lower ppb concentration were demonstrated with the electrochemical ethylene gas sensor. The system separates ethylene gas and humidity. The chromatograms obtained from the system are stable, and the results are 1.2% repeatable in five similar measurements. The statistical calculation of the gas chromatographic system shows that a concentration of 2.3 ppb of ethylene gas can be detected through this system. PMID:28991173
NASA Astrophysics Data System (ADS)
Hanley, Traci A.; Saadawi, Ryan; Zhang, Peng; Caruso, Joseph A.; Landero-Figueroa, Julio
2014-10-01
The production of commercially available products marketed to contain silver nanoparticles is rapidly increasing. Species-specific toxicity is a phenomenon associated with many elements, including silver, making it imperative to develop a method to identify and quantify the various forms of silver (namely, silver ions vs. silver nanoparticles) possibly present in these products. In this study a method was developed using high performance liquid chromatography (HPLC) with ultraviolet (UV-VIS) and inductively coupled mass spectrometric (ICP-MS) detection to separate starch stabilized silver nanoparticles (AgNPs) and silver ions (Ag+) by cation exchange chromatography with 0.5 M nitric acid mobile phase. The silver nanoparticles and ions were baseline resolved with an ICP-MS response linear over four orders of magnitude, 0.04 mg kg- 1 detection limit, and 90% chromatographic recovery for silver solutions containing ions and starch stabilized silver nanoparticles smaller than 100 nm.
Portable gas chromatograph mass spectrometer for on-site chemical analyses
Haas, Jeffrey S.; Bushman, John F.; Howard, Douglas E.; Wong, James L.; Eckels, Joel D.
2002-01-01
A portable, lightweight (approximately 25 kg) gas chromatograph mass spectrometer, including the entire vacuum system, can perform qualitative and quantitative analyses of all sample types in the field. The GC/MS has a conveniently configured layout of components for ease of serviceability and maintenance. The GC/MS system can be transported under operating or near-operating conditions (i.e., under vacuum and at elevated temperature) to reduce the downtime before samples can be analyzed on-site.
Comparative bioavailability of carbimazole and methimazole.
Jansson, R; Dahlberg, P A; Lindström, B
1983-10-01
In this study we investigated the oral bioavailability of therapeutic doses of two antithyroid drugs, methimazole and carbimazole, in seven euthyroid subjects. To increase the statistical power deuterium-labeled methimazole was given orally as an internal standard together with the tested drugs. Using a recently described highly sensitive gas chromatographic-mass spectrometric assay for methimazole we found that intake of 15 mg carbimazole resulted in plasma concentrations of methimazole and pharmacokinetic data comparable to intake of an equimolar amount of methimazole, i. e., 9.2 mg. Maximum concentrations of 163 and 149 ng/ml, respectively, were reached in both instances at 0.9 h after intake of 15 mg carbimazole and 10 mg methimazole. The plasma half-life was 5.7 and 5.4 h, respectively. In contrast to previous suggestions the interindividual differences in pharmacokinetics were small. In conclusion, carbimazole was rapidly and totally bioactivated to methimazole, and the drugs should be regarded as equipotent when compared on a molar basis.
Weigel, Stefan; Kuhlmann, Jan; Hühnerfuss, Heinrich
2002-08-05
An analytical method is presented, which allows the simultaneous extraction of neutral and acidic compounds from 20-L seawater samples at ambient pH (approximately 8.3). It is based on a solid-phase extraction by means of a polystyrene-divinylbenzene sorbent and gas chromatographic-mass spectrometric detection, and provides detection limits in the lower pg/L range. The method was applied to the screening of samples from different North Sea areas for clofibric acid, diclofenac, ibuprofen, ketoprofen, propyphenazone, caffeine and N,N-diethyl-3-toluamide (DEET). Whereas clofibric acid, caffeine and DEET showed to be present throughout the North Sea in concentrations of up to 1.3, 16 and 1.1 ng/L, respectively, propyphenazone could only be detected after further clean-up. Diclofenac and ibuprofen were found in the estuary of the river Elbe (6.2 and 0.6 ng/L, respectively) but in none of the marine samples. Ketoprofen was below the detection limit in all samples.
Self-leveling mortar as a possible cause of symptoms associated with "sick building syndrome".
Lundholm, M; Lavrell, G; Mathiasson, L
1990-01-01
In newly constructed houses and buildings in which self-leveling mortar containing casein has been used, residents and office employees have noted a bad odor and have complained of headache, eye and throat irritation, and tiredness. These problems were suspected to result from the degradation products emitted from the mortar. Samples obtained from dry mortar powder and from mortar in buildings where casein was used and from control buildings were found to contain microorganisms (mean of 10(2) culture forming units/g). Environmental species were predominantly found, e.g., Bacillus, Clostridium, Micrococcus, and Propionibacterium. Fungi were found occasionally; no evidence of bacterial degradation was found. Headspace and gas chromatographic-mass spectrometric analysis of air from the newly constructed houses and from hydroxide-degraded casein revealed the presence of amines in the 0.003-0.013 ppm range and the presence of ammonia and sulfhydryl compounds, all of which in low concentrations can cause the symptoms observed. These substances, however, were not detected in control buildings.
2-methylanthraquinone as a marker of occupational exposure to teak wood dust in boatyards.
Gori, Giampaolo; Carrieri, Mariella; Scapellato, Maria Luisa; Parvoli, Giorgio; Ferrara, Daniela; Rella, Rocco; Sturaro, Alberto; Bartolucci, Giovanni Battista
2009-01-01
A new gas chromatographic/mass spectrometric (GC/MS) method was developed to detect 2-methylanthraquinone (2-MeA) in wood dust. 2-MeA is present in teak wood (a suspected human carcinogen) but not in oak, beech, mahogany, birch, ash or pine. The method involved collection of workplace dust on filters and extraction of 2-MeA with methanol and GC/MS analysis. The method was tested on teak wood dust samples (n = 43) collected on polyvinylchloride membrane filters during various work operations in four small factories making furniture and fittings for leisure craft and boatyards (air teak wood dust concentration: range 0.32-14.32 mg m(-3)). A high correlation coefficient for the content of 2-MeA versus teak dust was obtained (logarithmic correlation: y = 1.5308x + 0.0998, r = 0.9215). Determination of airborne 2-MeA is a useful technique to confirm occupational exposure to teak wood dust.
Skjevrak, Ingun; Brede, Cato; Steffensen, Inger-Lise; Mikalsen, Arne; Alexander, Jan; Fjeldal, Per; Herikstad, Hallgeir
2005-10-01
A procedure used by the Norwegian Food Safety Authority for surveillance of contaminants from plastic food contact materials (polyolefin drinking bottles, water boilers, polyamide cooking utensils and plastic multi-layer materials) is described. It is based on gas chromatographic-mass spectrometric (GC/MS) analysis of food simulants exposed to plastic materials. Most migrants were substances not-intentionally added to the plastic (degradation products, impurities) or originated from non-plastic components, such as printing inks, adhesives, not-listed additives, solvents and coatings. Hence, the majority of the identified migrants were regulated by the general statements in the EU Framework Regulation, which neither specify limits nor requirements regarding risk assessment, rather than by specific migration controls. Risk assessment has been carried out for selected non-authorized substances. The analysis and the management of these substances and materials with respect to safety represents a challenge to the food authorities.
King, J W; King, L J
1996-01-01
Because of the increase in use of the newer benzodiazepines, we explored the opportunity to develop a gas chromatographic-mass spectrometric (GC-MS) method that encompasses most of the widely prescribed benzodiazepines in use today. The benzodiazepines included in our study are nordiazepam, oxazepam, temazepam, lorazepam, alpha-hydroxyalprazolam, alpha-hydroxytriazolam, desalkylflurazepam, and 2-hydroxyethylflurazepam. Using 1.0 mL of urine as the matrix, we added the enzyme Glusulase and incubated the specimens for 2 h to obtain the free drugs. The hydrolyzed samples were then loaded onto a Toxi-Lab Spec VC MP3 column containing a 15-mg disc. On-disc derivatization was accomplished by adding N-methyl-N-(t-butyldimethylsilyl) trifluroacetamide (MTBSTFA) with 1% TBDMSCI to the disc. The derivatives were then placed in a GC vial and analyzed by GC-MS in the selected ion monitoring mode. These results were then compared to confirmed positives by the traditional acid hydrolysis GC-MS method.
Good quantification practices of flavours and fragrances by mass spectrometry.
Begnaud, Frédéric; Chaintreau, Alain
2016-10-28
Over the past 15 years, chromatographic techniques with mass spectrometric detection have been increasingly used to monitor the rapidly expanded list of regulated flavour and fragrance ingredients. This trend entails a need for good quantification practices suitable for complex media, especially for multi-analytes. In this article, we present experimental precautions needed to perform the analyses and ways to process the data according to the most recent approaches. This notably includes the identification of analytes during their quantification and method validation, when applied to real matrices, based on accuracy profiles. A brief survey of application studies based on such practices is given.This article is part of the themed issue 'Quantitative mass spectrometry'. © 2016 The Authors.
A High Pressure Pulsed Expansion Valve for Gases, Liquids, and Supercritical Fluids
NASA Astrophysics Data System (ADS)
Köster, C.; Grotemeyer, J.; Schlag, E. W.
1990-12-01
A novel design of a pulsed valve for coupling chromatographic techniques with gaseous and liquid mobile phases to a time-of-flight mass spectrometer with multiphoton ionization (MUPI) is presented. The valve can be operated in low pressure regions ( <10 bar) up to temperatures of 350 °C and at higher pressures (300 bar) up to temperatures of 200 °C. Pulse widths lower than 100 μs could be measured. First results demonstrate the ability of interfacing of liquid chromatography to MUPI-mass spectrometry. Additional coupling of CO2-laser desorption to the valve allows the interface to be used for mass spectrometric measurements of nonvolatile biomolecules.
Andersen, Aaron John Christian; Hansen, Per Juel; Jørgensen, Kevin; Nielsen, Kristian Fog
2016-12-20
Dynamic cluster analysis (DCA) is an automated, unbiased technique which can identify Cl, Br, S, and other A + 2 element containing metabolites in liquid chromatographic high-resolution mass spectrometric data. DCA is based on three features, primarily the previously unutilized A + 1 to A + 2 isotope cluster spacing which is a strong classifier in itself but improved with the addition of the monoisotopic mass, and the well-known A:A+2 intensity ratio. Utilizing only the A + 1 to A + 2 isotope cluster spacing and the monoisotopic mass it was possible to filter a chromatogram for metabolites which contain Cl, Br, and S. Screening simulated isotope patterns of the Antibase Natural Products Database it was determined that the A + 1 to A + 2 isotope cluster spacing can be used to correctly classify 97.4% of molecular formulas containing these elements, only misclassifying a few metabolites which were either over 2800 u or metabolites which contained other A + 2 elements, such as Cu, Ni, Mg, and Zn. It was determined that with an interisotopic mass accuracy of 1 ppm, in a fully automated process, using all three parameters, it is possible to specifically filter a chromatogram for S containing metabolites with monoisotopic masses less than 825 u. Furthermore, it was possible to specifically filter a chromatogram for Cl and Br containing metabolites with monoisotopic masses less than 1613 u. Here DCA is applied on (i) simulated isotope patterns of the Antibase natural products databases, (ii) LC-QTOF data of reference standards, and (iii) LC-QTOF data of crude extracts of 10 strains of laboratory grown cultures of the microalga Prymnesium parvum where it identified known metabolites of the prymnesin series as well as over 20 previously undescribed prymnesin-like molecular features.
MASS SPECTROMETRIC ANALYSIS AND CHARACTERIZATION OF KEPONE IN ENVIRONMENTAL AND HUMAN SAMPLES
A specific portion of our environment has been contaminated with Kepone, or chlordecone. Additionally, some specific human exposures to high concentrations of Kepone have been confirmed. Gas chromatography mass spectrometry involving chemical ionization and high resolution mass s...
Gruendling, Till; Guilhaus, Michael; Barner-Kowollik, Christopher
2008-09-15
We report on the successful application of size exclusion chromatography (SEC) combined with electrospray ionization mass spectrometry (ESI-MS) and refractive index (RI) detection for the determination of accurate molecular weight distributions of synthetic polymers, corrected for chromatographic band broadening. The presented method makes use of the ability of ESI-MS to accurately depict the peak profiles and retention volumes of individual oligomers eluting from the SEC column, whereas quantitative information on the absolute concentration of oligomers is obtained from the RI-detector only. A sophisticated computational algorithm based on the maximum entropy principle is used to process the data gained by both detectors, yielding an accurate molecular weight distribution, corrected for chromatographic band broadening. Poly(methyl methacrylate) standards with molecular weights up to 10 kDa serve as model compounds. Molecular weight distributions (MWDs) obtained by the maximum entropy procedure are compared to MWDs, which were calculated by a conventional calibration of the SEC-retention time axis with peak retention data obtained from the mass spectrometer. Comparison showed that for the employed chromatographic system, distributions below 7 kDa were only weakly influenced by chromatographic band broadening. However, the maximum entropy algorithm could successfully correct the MWD of a 10 kDa standard for band broadening effects. Molecular weight averages were between 5 and 14% lower than the manufacturer stated data obtained by classical means of calibration. The presented method demonstrates a consistent approach for analyzing data obtained by coupling mass spectrometric detectors and concentration sensitive detectors to polymer liquid chromatography.
Martens-Lobenhoffer, J
1999-08-01
A gas chromatographic-mass spectrometric (GC-MS) assay for the determination of thiopental and its main metabolite pentobarbital in human plasma is presented in this study. The sample preparation consists only in the addition of the internal standard barbital and an acidic extraction with ethyl acetate. Analytical separation is accomplished on a RTX-1 15 m x 0.25 mm capillary column with a film thickness of 0.5 micron. The effluent is observed by a mass selective detector operating in the single ion monitoring mode. The limits of detection are 5 ng/ml for pentobarbital and 10 ng/ml for thiopental, the intra-day variabilities are 2.2% and 4.0% and the inter-day variabilities are 3.3% and 7.1% at concentrations of 5 micrograms/ml, respectively. Applying this assay, the stability of thiopental and pentobarbital in human plasma was tested at concentrations of 5 micrograms/ml each. Thiopental is stable in human plasma at least over 41 days stored at -20 degrees C and 5 degrees C, respectively. A decay of about 2%/day is observed under storage at ambient temperature (19-20 degrees C). Pentobarbital is stable under all storage conditions. Methanolic solutions of thiopental are stable for 83 days under storage at 5 degrees C. Aqueous solutions of thiopental-sodium are stable for at least 23 days under storage at 5 degrees C or ambient temperature.
Slabizki, Petra; Fischer, Claus; Legrum, Charlotte; Schmarr, Hans-Georg
2015-09-09
Natural cork stoppers with sensory deviations other than the typical cork taint were subgrouped according to their sensory descriptions and compared with unaffected control cork stoppers. The assessment of purge and trap extracts obtained from corresponding cork soaks was performed by heart-cut multidimensional gas chromatography-olfactometry (MDGC-O). The identification of compounds responsible for atypical cork taint detected in MDGC-O was further supported with additional multidimensional GC analysis in combination with mass spectrometric detection. Geosmin and 2-methylisoborneol were mainly found in cork stoppers described as moldy and cellarlike; 3-isopropyl-2-methoxypyrazine and 3-isobutyl-2-methoxypyrazine were found in cork stoppers described with green attributes. Across all cork subgroups, the impact compound for typical cork taint, 2,4,6-trichloroanisole (TCA), was present and is therefore a good marker for cork taint in general. Another potent aroma compound, 3,5-dimethyl-2-methoxypyrazine (MDMP), was also detected in each subgroup, obviously playing an important role with regard to the atypical cork taint. Sensory deviations possibly affecting the wine could be generated by MDMP and its presence should thus be monitored in routine quality control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ischia, Marco, E-mail: marco.ischia@ing.unitn.it; Maschio, Roberto Dal; Grigiante, Maurizio
2011-01-15
Wastewater sewage sludge was co-pyrolyzed with a well characterized clay sample, in order to evaluate possible advantages in the thermal disposal process of solid waste. Characterization of the co-pyrolysis process was carried out both by thermogravimetric-mass spectrometric (TG-MS) analysis, and by reactor tests, using a lab-scale batch reactor equipped with a gas chromatograph for analysis of the evolved gas phase (Py-GC). Due to the presence of clay, two main effects were observed in the instrumental characterization of the process. Firstly, the clay surface catalyzed the pyrolysis reaction of the sludge, and secondly, the release of water from the clay, atmore » temperatures of approx. 450-500 deg. C, enhanced gasification of part of carbon residue of the organic component of sludge following pyrolysis. Moreover, the solid residue remaining after pyrolysis process, composed of the inorganic component of sludge blended with clay, is characterized by good features for possible disposal by vitrification, yielding a vitreous matrix that immobilizes the hazardous heavy metals present in the sludge.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
... was required for gas chromatography with mass selective detection (GC/MSD) but not for liquid... detection (LOD = 0.01) and a gas liquid chromatography (GLC) method with a flame photometric detection (LOD... quantification by high performance liquid chromatography with tandem mass spectrometric detection (HPLC/MS/MS...
Nowak, Jeremy A; Weber, Robert J; Goldstein, Allen H
2018-03-12
The ability to structurally characterize and isomerically quantify crude oil hydrocarbons relevant to refined fuels such as motor oil, diesel, and gasoline represents an extreme challenge for chromatographic and mass spectrometric techniques. This work incorporates two-dimensional gas chromatography coupled to a tunable vacuum ultraviolet soft photoionization source, the Chemical Dynamics Beamline 9.0.2 of the Advanced Light Source at the Lawrence Berkeley National Laboratory, with a time-of-flight mass spectrometer (GC × GC-VUV-TOF) to directly characterize and isomerically sum the contributions of aromatic and aliphatic species to hydrocarbon classes of four crude oils. When the VUV beam is tuned to 10.5 ± 0.2 eV, both aromatic and aliphatic crude oil hydrocarbons are ionized to reveal the complete chemical abundance of C 9 -C 30 hydrocarbons. When the VUV beam is tuned to 9.0 ± 0.2 eV only aromatic hydrocarbons are ionized, allowing separation of the aliphatic and aromatic fractions of the crude oil hydrocarbon chemical classes in an efficient manner while maintaining isomeric quantification. This technique provides an effective tool to determine the isomerically summed aromatic and aliphatic hydrocarbon compositions of crude oil, providing information that goes beyond typical GC × GC separations of the most dominant hydrocarbon isomers.
Živković Semren, Tanja; Brčić Karačonji, Irena; Safner, Toni; Brajenović, Nataša; Tariba Lovaković, Blanka; Pizent, Alica
2018-01-01
Non-targeted metabolomics research of human volatile urinary metabolome can be used to identify potential biomarkers associated with the changes in metabolism related to various health disorders. To ensure reliable analysis of urinary volatile organic metabolites (VOMs) by gas chromatography-mass spectrometry (GC-MS), parameters affecting the headspace-solid phase microextraction (HS-SPME) procedure have been evaluated and optimized. The influence of incubation and extraction temperatures and times, coating fibre material and salt addition on SPME efficiency was investigated by multivariate optimization methods using reduced factorial and Doehlert matrix designs. The results showed optimum values for temperature to be 60°C, extraction time 50min, and incubation time 35min. The proposed conditions were applied to investigate urine samples' stability regarding different storage conditions and freeze-thaw processes. The sum of peak areas of urine samples stored at 4°C, -20°C, and -80°C up to six months showed a time dependent decrease over time although storage at -80°C resulted in a slight non-significant reduction comparing to the fresh sample. However, due to the volatile nature of the analysed compounds, more than two cycles of freezing/thawing of the sample stored for six months at -80°C should be avoided whenever possible. Copyright © 2017 Elsevier B.V. All rights reserved.
Kasumov, Takhar; Gruca, Lourdes L.; Dasarathy, Srinivasan; Kalhan, Satish C.
2012-01-01
A gas chromatographic-mass spectrometric (GC-MS) method for the simultaneous measurement of isotopic enrichment and concentration of guanidinoacetic acid and creatine in plasma sample for kinetic studies is reported. The method, based on preparation of the bis(trifluoromethyl)-pyrimidine methyl ester derivatives of guanidinoacetic acid and creatine, is robust and sensitive. The lowest measurable m1 and m3 enrichment for guanidinoacetic acid and creatine, respectively, was 0.3%. The calibration curves for measurements of concentration were linear over a range of 0.5-250 μM guanidinoacetic acid and 2-500 μM for creatine. The method was reliable for inter-assay and intra-assay precision, accuracy and linearity. The technique was applied in a healthy adult to determine in vivo fractional synthesis rate of creatine using primed- constant rate infusion of [1-13C]glycine. It was found that isotopic enrichment of guanidinoacetic acid reached plateau by 30 min of infusion of [1-13C]glycine, indicating either a small pool size or a rapid turnover rate or both, of guanidinoacetic acid. In contrast, tracer appearance in creatin was slow (slope: 0.00097), suggesting a large pool size and a slow rate of synthesis of creatine. This method can be used to estimate rate of synthesis of creatine in-vivo in human and animal studies. PMID:19646413
Lachenmeier, Dirk W; Kroener, Lars; Musshoff, Frank; Madea, Burkhard
2004-01-01
A fully automated procedure using alkaline hydrolysis and headspace solid-phase microextraction (HS-SPME), followed by on-fiber derivatization and gas chromatographic-mass spectrometric (GC-MS) detection has been developed for determination of cannabinoids in hemp food samples. After addition of a deuterated internal standard, the sample was hydrolyzed with sodium hydroxide and submitted to direct HS-SPME. After absorption of analytes for on-fiber derivatization, the fiber was placed directly into the headspace of a second vial containing N-methyl- N-trimethylsilyltrifluoroacetamide (MSTFA), before GC-MS analysis. Linearity was good for Delta(9)-tetrahydrocannabinol (THC), cannabidiol, and cannabinol; regression coefficients were greater than 0.99. Depending on the characteristics of the matrix the detection limits obtained ranged between 0.01 and 0.17 mg kg(-1) and the precision between 0.4 and 11.8%. In comparison with conventional liquid-liquid extraction this automated HS-SPME-GC-MS procedure is substantially faster. It is easy to perform, solvent-free, and sample quantities are minimal, yet it maintains the same sensitivity and reproducibility. The applicability was demonstrated by analysis of 30 hemp food samples. Cannabinoids were detected in all of the samples and it was possible to differentiate between drug-type and fiber-type Cannabis sativa L. In comparison with other studies relatively low THC concentrations between 0.01 and 15.53 mg kg(-1) were determined.
Podhorniak, Lynda V; Schenck, Frank J; Krynitsky, Alexander; Griffith, Francis
2004-01-01
A reversed-phase liquid chromatographic method with both fluorescence and mass spectrometric detection is presented for the determination of 13 parent N-methyl carbamate pesticides and their metabolites, as well as piperonyl butoxide, for a total of 24 compounds in selected fruits and vegetables. The commodities chosen were of special concern to the U.S. Environmental Protection Agency (EPA) because they had the least amount of monitoring data for dietary exposure estimates used in risk assessment. The method is based on a judicious selection of procedures from U.S. Food and Drug Administration sources such as the Pesticide Analytical Manual (Volume I), and Laboratory Information Bulletins, plus additional material from the chemical literature combined in a manner to recover the N-methyl carbamates and their metabolites at the 1 microg/kg or 1 part-per-billion level. The method uses an acetone extraction, followed by an aminopropyl solid-phase extraction cleanup. Determination of residues is by RP-LC, in which the liquid chromatograph is interfaced with either a fluorescence or a mass spectrometric detector. The method is designed so that a set of 6 samples can be prepared in 1 working day for overnight instrumental analysis. Recovery data are presented from analyses of selected commodities in some of EPA's fruit and vegetable crop groupings. A table listing relative retention times is presented for the N-methyl carbamates and their metabolites.
Srinubabu, Gedela; Ratnam, Bandaru Veera Venkata; Rao, Allam Appa; Rao, Medicherla Narasimha
2008-01-01
A rapid tandem mass spectrometric (MS-MS) method for the quantification of Oxcarbazepine (OXB) in human plasma using imipramine as an internal standard (IS) has been developed and validated. Chromatographic separation was achieved isocratically on a C18 reversed-phase column within 3.0 min, using a mobile phase of acetonitrile-10 mM ammonium formate (90 : 10 v/v) at a flow rate of 0.3 ml/min. Quantitation was achieved using multiple reaction monitoring (MRM) scan at MRM transitions m/z 253>208 and m/z 281>86 for OXB and the IS respectively. Calibration curves were linear over the concentration range of 0.2-16 mug/ml (r>0.999) with a limit of quantification of 0.2 mug/ml. Analytical recoveries of OXB from spiked human plasma were in the range of 74.9 to 76.3%. Plackett-Burman design was applied for screening of chromatographic and mass spectrometric factors; factorial design was applied for optimization of essential factors for the robustness study. A linear model was postulated and a 2(3) full factorial design was employed to estimate the model coefficients for intermediate precision. More specifically, experimental design helps the researcher to verify if changes in factor values produce a statistically significant variation of the observed response. The strategy is most effective if statistical design is used in most or all stages of the screening and optimizing process for future method validation of pharmacokinetic and bioequivalence studies.
Prasad, Satendra; Wouters, Eloy R; Dunyach, Jean-Jacques
2015-08-18
Ion sampling from an electrospray ionization (ESI) source was improved by increasing gas conductance of the MS inlet by 4.3-fold. Converting the gas throughput (Q) into sensitivity improvement was dependent on ion desolvation and handling of the gas load. Desolvation was addressed by using a novel slot shaped inlet that exhibited desolvation properties identical to the 0.58 mm i.d capillary. An assay tailored for "small molecules" at high chromatographic flow rate (500 μL/min) yielded a compound dependent 6.5 to 14-fold signal gain while analysis at nano chromatographic flow rate (300 nL/min) showed 2 to 3.5-fold improvement for doubly charged peptides. Improvement exceeding the Q (4.3-fold) at high chromatographic flow rate was explained by superior sampling of the spatially dispersed ion spray when using the slot shaped capillary. Sensitivity improvement across a wide range of chromatographic flow rate confirmed no compromise in ion desolvation with the increase in Q. Another improvement included less overflow of gas into the mass analyzer from the foreline region owing to the slot shape of the capillary. By doubling the roughing pump capacity and operating the electrodynamic ion funnel (EDIF) at ∼4 Torr, a single pumping stage was sufficient to handle the gas load. The transport of solvent clusters from the LC effluent into the mass analyzer was prevented by a "wavy shaped" transfer quadrupole and was compared with a benchmark approach that delivered ions orthogonally into a differentially pumped dual EDIF at comparable gas Q.
Swart, K J; Sutherland, F C; van Essen, G H; Hundt, H K; Hundt, A F
1998-12-18
An ultra-sensitive method for the determination of fluspirilene in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane/isoamyl alcohol, separated on a Phenomenex Luna C18 5 mu 150 x 2.1 mm column with a mobile phase consisting of methanol-water-acetic acid (600:400:1) at a flow-rate of 0.3 ml/min. Detection was achieved by a Finnigan Matt mass spectrometer (LCQ) at unit resolution in full scan mode scanning the product ion spectrum from m/z 130-500 and monitoring the transition of the protonated molecular ion at m/z 476.2, to the sum of the largest product ions m/z 371, 342 and 274 (MS-MS). Electrospray ionisation was used for ion production. The mean recovery for fluspirilene was 90% with a lower limit of quantification of 21.50 pg/ml using 1 ml plasma for extraction. This is the first chromatographic method described for the determination of fluspirilene in plasma that is accurate and sensitive enough to be used in pharmacokinetic studies.
2008-02-01
ABSTRACT See reprint. 15. SUBJECT TERMS Human plasma proteins, soman, nerve agent , bioscavenger, gas chromatography, mass spectrometry 16. SECURITY...usually referred to as nerve agents ) are tabun (ethyl dimethylamidocyanophosphate, or GA ), sarin (iso- propyl methylfluorophosphonate, or GB), soman...Pharmacology and toxicology of chemical warfare agents Ann. Acad. Med. Singapore 2&: 104-107 (1997). 11. C Macilwain. Study proves Iraq used nerve gas . Nature 3
Capillary gas chromatography with mass spectrometric detection is the most commonly used technique for analyzing samples from Superfund sites. While the U.S. EPA has developed target lists of compounds for which library mass spectra are available on most mass spectrometer data s...
Mass spectrometric determination of the composition of the Venus clouds
NASA Technical Reports Server (NTRS)
Herzog, R. F. K.
1973-01-01
The instrumentation is analyzed for determining the composition of the clouds on Venus. Direct analysis of the gas phase atmosphere, and the detection of ferrous chloride with a mass spectrometer are dicussed along with the mass analyzer, and the pre-separation of cloud particles from the ambient atmosphere.
NASA Technical Reports Server (NTRS)
Geller, Harold A.; Norris, Eugene; Warnock, Archibald, III
1991-01-01
Neural networks trained using mass spectra data from the National Institute of Standards and Technology (NIST) are studied. The investigations also included sample data from the gas chromatograph mass spectrometer (GCMS) instrument aboard the Viking Lander, obtained from the National Space Science Data Center. The work performed to data and the preliminary results from the training and testing of neural networks are described. These preliminary results are presented for the purpose of determining the viability of applying artificial neural networks in discriminating mass spectra samples from remote instrumentation such as the Mars Rover Sample Return Mission and the Cassini Probe.
Segura, J; Stramesi, C; Redón, A; Ventura, M; Sanchez, C J; González, G; San, L; Montagna, M
1999-03-05
The work presents an analytical strategy to detect drugs of abuse in hair. It involves two sequential steps: a screening by a simple enzyme-linked immunosorbent assay (ELISA) methodology to detect opiates, cocaine and its metabolites, and benzodiacepines, followed by confirmation of opiates and cocaine metabolites in positive samples by gas chromatography coupled to mass spectrometry (GC-MS). In the same GC-MS run other drugs for substitution therapy (e.g. methadone and its main metabolite) can also be detected. After a double washing of hair samples with dichloromethane, hair specimens were cut into small pieces and 10 mg samples were incubated in 2 ml of methanol-trifluoroacetic acid (9:1) mixture, overnight at 37 degrees C. Aliquots of the extract were then evaporated, reconstituted in buffer and analysed according to the ELISA procedure. Confirmation involved solid-phase extraction of another fraction of the extract kept at -20 degrees C, derivatization with heptafluorobutyric anhydride and hexafluoroisopropanol and detection of cocaine, benzoylecgonine, ecgonine methylester, cocaethylene, morphine, codeine, 6-monoacetylmorphine, methadone and 2-ethylidene-1.5-dimethyl-3,3-diphenylpirrolidine (methadone metabolite) by selective ion monitoring after gas chromatographic separation. During the development of the method it was verified that no more than 10% of cocaine, opiates and benzodiacepines were lost when dichloromethane was used to wash real samples. The results also confirmed the increase of extractability power of TFA when it was added to methanol: the recovery for the analytes (cocaine and its metabolites and opiates) added to methanol-TFA alone was of the order of 90% except for benzoylecgonine (75%), and the recovery for the analytes added to methanol-TFA extract of drug-free hair was about 90% for all analytes except for benzoylecgonine and 6-MAM (around 70%). Regarding the stability of labile compounds, only small amounts of ecgonine methylester (2.3%) and morphine (7.2%) were produced, from cocaine and 6-MAM respectively, after the whole extraction procedure and two weeks of storage of methanol-TFA extracts at -20 degrees C. Satisfactory results were obtained when the procedures were applied to the analysis of external proficiency testing hair samples and actual specimens from drug addicts.
Wada, Yoshinao; Dell, Anne; Haslam, Stuart M; Tissot, Bérangère; Canis, Kévin; Azadi, Parastoo; Bäckström, Malin; Costello, Catherine E; Hansson, Gunnar C; Hiki, Yoshiyuki; Ishihara, Mayumi; Ito, Hiromi; Kakehi, Kazuaki; Karlsson, Niclas; Hayes, Catherine E; Kato, Koichi; Kawasaki, Nana; Khoo, Kay-Hooi; Kobayashi, Kunihiko; Kolarich, Daniel; Kondo, Akihiro; Lebrilla, Carlito; Nakano, Miyako; Narimatsu, Hisashi; Novak, Jan; Novotny, Milos V; Ohno, Erina; Packer, Nicolle H; Palaima, Elizabeth; Renfrow, Matthew B; Tajiri, Michiko; Thomsson, Kristina A; Yagi, Hirokazu; Yu, Shin-Yi; Taniguchi, Naoyuki
2010-04-01
The Human Proteome Organisation Human Disease Glycomics/Proteome Initiative recently coordinated a multi-institutional study that evaluated methodologies that are widely used for defining the N-glycan content in glycoproteins. The study convincingly endorsed mass spectrometry as the technique of choice for glycomic profiling in the discovery phase of diagnostic research. The present study reports the extension of the Human Disease Glycomics/Proteome Initiative's activities to an assessment of the methodologies currently used for O-glycan analysis. Three samples of IgA1 isolated from the serum of patients with multiple myeloma were distributed to 15 laboratories worldwide for O-glycomics analysis. A variety of mass spectrometric and chromatographic procedures representative of current methodologies were used. Similar to the previous N-glycan study, the results convincingly confirmed the pre-eminent performance of MS for O-glycan profiling. Two general strategies were found to give the most reliable data, namely direct MS analysis of mixtures of permethylated reduced glycans in the positive ion mode and analysis of native reduced glycans in the negative ion mode using LC-MS approaches. In addition, mass spectrometric methodologies to analyze O-glycopeptides were also successful.
Petropoulou, Syrago-Styliani E; Duong, Wendy; Petreas, Myrto; Park, June-Soo
2014-08-22
Hydroxylated polybrominated diphenyl ethers (OH-PBDEs) are formed from the oxidative metabolism of polybrominated diphenyl ethers (PBDEs) in humans, rats and mice, but their quantitation in human blood and other matrices with liquid chromatography-mass spectrometric techniques has been a challenge. In this study, a novel analytical method was developed and validated using only 250 μL of human serum for the quantitation of twelve OH-PBDEs, fully chromatographically separated in a 15 min analytical run. This method includes two novel approaches: an enzymatic hydrolysis procedure and a chromatographic separation using a mixed mode chromatography column. The enzymatic hydrolysis (EH) was found critical for 4'-OH-BDE17, which was not detectable without it. For the sample clean up, a solid phase extraction protocol was developed and validated for the extraction of the 12 congeners from human serum. In addition, for the first time baseline resolution of two components was achieved that correspond to a single peak previously identified as 6'-OH-BDE99. The method was validated for linearity, accuracy, precision, matrix effects, limit of quantification, limit of detection, sample stability and overall efficiency. Recoveries (absolute and relative) ranged from 66 to 130% with relative standard deviations <21% for all analytes. Limit of detection and quantitation ranged from 4 to 90 pg mL(-1) and 6-120 pg mL(-1), respectively, with no carry over effects. This method was applied in ten commercially available human serum samples from the general US population. The mean values of the congeners detected in all samples are 4'-OH-BDE17 (34.2 pg mL(-1)), 4-OH-BDE42 (33.9 pg mL(-1)), 5-OH-BDE47 (17.5 pg mL(-1)) and 4'-OH-BDE49 (12.4 pg mL(-1)). Copyright © 2014 Elsevier B.V. All rights reserved.
Some Phytomonas and Herpetomonas species form unique iso-branched polyunsaturated fatty acids.
Fish, W R; Holz, G G; Beach, D H
1982-01-01
Four trypanosomatid flagellates of the genera Phytomonas and Herpetomonas have been found to carry out the de novo biosynthesis of a variety of iso-branched, C18, C20 and C22, polyunsaturated fatty acids, with 2-5 methylene-interrupted double bonds, which have not been described heretofore from natural materials; iso-C18 delta 6,9, iso-C18 delta 9,12, iso-C20 delta 8,11,14, iso-C 20 delta 5,8,11,14, iso-C22 delta 4,7,10,13,16. Identifications were based upon combinations of chromatographic, chemical degradative, mass spectrometric and proton nuclear magnetic resonance spectrometric techniques. Under appropriate culture conditions, 85% of the total fatty acids of the organisms were branched. The subject trypanosomatids are recommended as model organisms with which to investigate influences of the physical properties of phospholipid fatty acyl groups on eukaryotic cell membrane functions.
da Silveira, Géssica Domingos; Faccin, Henrique; Claussen, Luis; Goularte, Rayane Bueno; Do Nascimento, Paulo C; Bohrer, Denise; Cravo, Margareth; Leite, Leni F M; de Carvalho, Leandro Machado
2016-07-29
We present a sensitive liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric (UHPLC-APPI-MS/MS) method for the determination of selected organosulfur compounds in Brazilian asphalt cements. It was possible to detect 14 organosulfur compounds of different classes where sulfoxides and sulfones presented higher sensibility in ionization than thiophenes and aromatic sulfides. A dopant-assisted APPI method was also tested, however, when chromatographic flow rate was optimized a decrease in signal was observed for all compounds. PAHs were tested and ruled out as possible interfering compounds and the matrix effect of asphalt cements was within an acceptable range for the quantification of organosulfur compounds. The proposed method was found to have satisfactory linearity and accuracy with recoveries between 83.85 and 110.28% for thianaphthene and 3-methylbenzothiophene, respectively. Therefore, the method allowed the characterization of organosulfur compounds in Brazilian asphalt cements and demonstrated changes in the amount quantified in asphaltenic and maltenic fractions after the RTFOT+SUNTEST aging process. Copyright © 2016 Elsevier B.V. All rights reserved.
Chen, Dawei; Zhang, Yiping; Miao, Hong; Zhao, Yunfeng; Wu, Yongning
2015-11-11
A novel dispersive micro solid phase extraction (DMSPE) method based on a polymer cation exchange material (PCX) was applied to the simultaneous determination of the 30 triazine herbicides in drinking water with ultrahigh-performance liquid chromatography-high-resolution mass spectrometric detection. Drinking water samples were acidified with formic acid, and then triazines were adsorbed by the PCX sorbent. Subsequently, the analytes were eluted with ammonium hydroxide/acetonitrile. The chromatographic separation was performed on an HSS T3 column using water (4 mM ammonium formate and 0.1% formic acid) and acetonitrile (0.1% formic acid) as the mobile phase. The method achieved LODs of 0.2-30.0 ng/L for the 30 triazines, with recoveries in the range of 70.5-112.1%, and the precision of the method was better than 12.7%. These results indicated that the proposed method had the advantages of convenience and high efficiency when applied to the analysis of the 30 triazines in drinking water.
Lam, Maggie P Y; Scruggs, Sarah B; Kim, Tae-Young; Zong, Chenggong; Lau, Edward; Wang, Ding; Ryan, Christopher M; Faull, Kym F; Ping, Peipei
2012-08-03
The regulation of mitochondrial function is essential for cardiomyocyte adaptation to cellular stress. While it has long been understood that phosphorylation regulates flux through metabolic pathways, novel phosphorylation sites are continually being discovered in all functionally distinct areas of the mitochondrial proteome. Extracting biologically meaningful information from these phosphorylation sites requires an adaptable, sensitive, specific and robust method for their quantification. Here we report a multiple reaction monitoring-based mass spectrometric workflow for quantifying site-specific phosphorylation of mitochondrial proteins. Specifically, chromatographic and mass spectrometric conditions for 68 transitions derived from 23 murine and human phosphopeptides, and their corresponding unmodified peptides, were optimized. These methods enabled the quantification of endogenous phosphopeptides from the outer mitochondrial membrane protein VDAC, and the inner membrane proteins ANT and ETC complexes I, III and V. The development of this quantitative workflow is a pivotal step for advancing our knowledge and understanding of the regulatory effects of mitochondrial protein phosphorylation in cardiac physiology and pathophysiology. This article is part of a Special Issue entitled: Translational Proteomics. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Schulz, Anke; Trage, Claudia; Schwarz, Helmut; Kroh, Lothar W.
2007-05-01
A new method is presented which allows the simultaneous detection of various [alpha]-dicarbonyl compounds generated in the course of the nonenzymatic browning reaction initiated by thermal treatment of l-ascorbic acid, namely: glyoxal, methylglyoxal, diacetyl, 3-deoxy-l-pentosone, and l-threosoneE 3-Deoxy-l-threosone was successfully identified as a new C4-[alpha]-dicarbonyl structure for the first time in the degradation of Vitamin C by application of this non-chromatographic mass spectrometric approach. Moreover, a more detailed elucidation of the mechanistic scenario with respect to the oxidative and nonoxidative pathways is presented by using dehydro-l-ascorbic acid and 2,3-diketo-l-gulonic acid instead of l-ascorbic acid as a starting material. Furthermore, the postulated pathways are corroborated with the aid of 13C-isotopic labeling studies. The investigations were extended to baby food, and the successful detection of [alpha]-dicarbonyl compounds characteristic for Vitamin C degradation proved the matrix tolerance of the introduced method.
Bossi, Rossana; Rastogi, Suresh C; Bernard, Guillaume; Gimenez-Arnau, Elena; Johansen, Jeanne D; Lepoittevin, Jean-Pierre; Menné, Torkil
2004-05-01
This paper describes a validated liquid chromatographic-tandem mass spectrometric method for quantitative analysis of the potential oak moss allergens atranol and chloroatranol in perfumes and similar products. The method employs LC-MS-MS with electrospray ionization (ESI) in negative mode. The compounds are analysed by selective reaction monitoring (SRM) of 2 or 3 ions for each compound in order to obtain high selectivity and sensitivity. The method has been validated for the following parameters: linearity; repeatability; recovery; limit of detection; and limit of quantification. The limits of detection, 5.0 ng/mL and 2.4 ng/mL, respectively, for atranol and chloroatranol, achieved by this method allowed identification of these compounds at concentrations below those causing allergic skin reactions in oak-moss-sensitive patients. The recovery of chloratranol from spiked perfumes was 96+/-4%. Low recoveries (49+/-5%) were observed for atranol in spiked perfumes, indicating ion suppression caused by matrix components. The method has been applied to the analysis of 10 randomly selected perfumes and similar products.
Ito, Shinya; Tsukada, Katsuo
2002-01-11
An evaluation of the feasibility of liquid chromatography-mass spectrometry (LC-MS) with atmospheric pressure ionization was made for quantitation of four diarrhetic shellfish poisoning toxins, okadaic acid, dinophysistoxin-1, pectenotoxin-6 and yessotoxin in scallops. When LC-MS was applied to the analysis of scallop extracts, large signal suppressions were observed due to coeluting substances from the column. To compensate for these matrix signal suppressions, the standard addition method was applied. First, the sample was analyzed and then the sample involving the addition of calibration standards is analyzed. Although this method requires two LC-MS runs per analysis, effective correction of quantitative errors was found.
Juorio, A. V.; McQuade, P. S.
1983-01-01
The endogenous concentrations of p- and m-hydroxyphenylacetic acid in the mouse caudate nucleus were determined by a gas chromatographic or a gas chromatographic-mass spectrometric technique and the concentrations were about 30 and 11 ng g-1 respectively. The subcutaneous administration of (+)-butaclamol (1 mg kg-1), haloperidol (5 mg kg-1), molindone (100 mg kg-1), sulpiride (50 mg kg-1) or chlorpromazine (20 mg kg-1) increased the concentration of mouse striatal p- and m-hydroxyphenylacetic acid; the effects were observed at 2 h after drug administration. Lower doses of chlorpromazine (2 mg kg-1), haloperidol (0.2 mg kg-1) and molindone (2 mg kg-1) did not affect p- or m-hydroxyphenylacetic acid concentrations. The time course for the concentration changes produced by chlorpromazine (20 mg kg-1) revealed that the formation of the metabolites occurred within 30 min after its administration and that their efflux from the caudate nucleus took at least 4 h for p-hydroxyphenylacetic acid and more than 8 h for m-hydroxyphenylacetic acid. Promethazine and (-)-butaclamol which have chemical structures related to chlorpromazine or (+)-butaclamol respectively but which lack antipsychotic activity, produced no effect on striatal p- or m-hydroxyphenylacetic acid concentrations. The results suggest that antipsychotic drugs increase the utilization of mouse striatal p- and m-tyramine and that after use the amines are metabolized by monoamine oxidase to form p- or m-hydroxyphenylacetic acid. The synthesis of the acid metabolites occurs within 30 min after chlorpromazine administration and their efflux from the caudate nucleus takes from 4-8 h. PMID:6196070
Kubinec, Róbert; Blaško, Jaroslav; Górová, Renáta; Addová, Gabriela; Ostrovský, Ivan; Amann, Anton; Soják, Ladislav
2011-04-01
Isomer mixtures of monomethyl branched saturated C7-C23 fatty acid methyl esters (FAME) were prepared by performing a methylene insertion reaction to the straight chain FAME and this study model was completed by using commercially available standards of C4-C7 FAME. The equivalent chain lengths (ECL) of all 220 C4-C23 monomethyl branched FAME on OV-1 stationary phase were measured, achieving an average repeatability of ±0.0004 ECL units. The monomethyl branched FAME was identified by GC on the basis of regularity of the fractional chain lengths (FCL) dependence on the number of carbon atoms (C(z)) of individual homologous series of methyl 2-, 3-, …, 21-FAME. The prediction of retention of the first homologues, having the new position of methyl group beginning at higher carbon atoms number, and analogously for the second, third, fourth, and other members of the homologous series, allowed the dependence FCL=f(C(z)) for the first and subsequent members of beginning homologous of monomethyl derivatives of FAME. The identification was confirmed by mass spectrometry. All of the methyl isomers of FAME, which could not be completely separated by gas chromatography due to having a methyl group in surroundings of the middle of the carbon chain, were resolved by mass spectrometry using deconvolution in a SIM-mode. Measured gas chromatographic and mass spectrometric data were applied for identification of the monomethyl branched saturated FAME in tongue coating. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Burian, Cosmin; Brezmes, Jesus; Vinaixa, Maria; Llobet, Eduard; Vilanova, Xavier; Cañellas, Nicolau; Correig, Xavier
2009-05-01
This paper presents the work done with Fuzzy ARTMAP neural networks in order to improve the performance of mass spectrometry-based electronic noses using the time retention of a chromatographic column as additional information. Solutions of nine isomers of dimethylphenols and ethylphenols were used in this experiment. The gas chromatograph mass spectrometer response was analyzed with an in-house developed Fuzzy ARTMAP neural network, showing that the combined information (GC plus MS) gives better results than MS information alone.
Fixture For Sampling Volatile Materials In Containers
NASA Technical Reports Server (NTRS)
Melton, Donald; Pratz, Earl Howard
1995-01-01
Fixture based on T-connector enables mass-spectrometric analysis of volatile contents of cylindrical containers without exposing contents to ambient conditions. Used to sample volatile contents of pressurized containers, contents of such enclosed processing systems as gas-phase reactors, gases in automotive emission systems, and gas in hostile environments.
Linked gas chromatograph-thermal energy analyzer/ion trap mass spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alcaraz, A.; Martin, W.H.; Andresen, B.D.
1991-05-01
The capability of comparing a nitrogen chromatogram generated from a gas chromatograph (GC, Varian model 3400) linked to a thermal energy analyzer (TEA, Thermedics Inc. Model 610) with a total ion chromatogram (from a Finnigan-MAT Ion Trap Mass Spectrometer, ITMS) has provided a new means to screen and identifying trace levels of nitrogen-containing compounds in complex mixtures. Prior to the work described here, it has not been possible to simultaneously acquire TEA and MS data. What was needed was a viable GC-TEA/ITMS interface to combine the capabilities of both instruments. 4 figs.
Nakamoto, Akihiro; Nishida, Manami; Saito, Takeshi; Kishiyama, Izumi; Miyazaki, Shota; Murakami, Katsunori; Nagao, Masataka; Namura, Akira
2010-02-19
A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d(5) was used as an internal standard. The linear ranges were 0.01-5.0 microg mL(-1) for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 microg mL(-1) for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation > or = 0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 microg mL(-1) of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio > or = 3) in urine was 5 ng mL(-1) for MA and MDMA and 10 ng mL(-1) for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation. Copyright 2009 Elsevier B.V. All rights reserved.
In vitro analysis of the properties of Beiqishen tea.
Blázovics, A; Szentmihályi, K; Lugasi, A; Balázs, A; Hagymási, K; Bányai, E; Then, M; Rapavi, E; Héthelyi, E
2003-10-01
Chinese Beiqishen tea was studied in an in vitro test system. Phytochemical screening, trace element analysis, and the analysis of antioxidant properties were carried out. Characteristic constituents were determined by chromatographic (capillary gas chromatography and GCQ Ion Trap mass spectrometry) and spectrometric (ultraviolet and UV-VIS) methods. Element concentrations were determined by inductively coupled plasma optical emission spectrometry. Antioxidant capacity was studied by spectrophotometric and luminometric techniques using a Berthold Lumat 9501 luminometer. Hydrogen-donating activity, reducing power, and total scavenger capacity were measured. Total polyphenol content was 20.77 +/- 0.52 g/100 g of drug; total flavonoid content was 0.485 +/- 0.036 g/100 g of drug; and tannin content was 9.063 +/- 0.782 g/100 g of drug. Caffeine content was 1.08 mg/100 g of drug. Essential oils were identified by gas chromatography: (+)-limonene (21%), p-cymene (1.7%), estragol (3.2%), beta-ocimene (1.4%), and thymol (2.6%). Metallic ion analysis showed significantly high concentrations of Al, As, Ba, Cr, Cu, Fe, Mn, Ni, and Ti in the drug. Antioxidant and scavenger properties were identified as a function of concentration. The tea infusion contained some non-desirable trace elements and caffeine in addition to polyphenols and tannins in high concentrations. Therefore, the consumption of this tea may involve risks.
Sotnikov, E E; Kir'ianova, L F; Mikhaĭlova, R I; Ryzhova, I N; Moskovkin, A S
2009-01-01
The paper provides the results of gas chromatographic analysis of organic impurities in the drinking water after its contact with various packs and filters made from polymer materials. Vapor-phase analysis in combination with selective gas chromatographic detectors was used to determine volatile substances and liquid extraction in combination with chromatographic mass-spectrometry was employed to identify high-boiling compounds. The release sources of toxic compounds from materials to water, the taste and odor of which is affected by them were studied.
Gas chromatographic/mass spectrometric and microbiological analyses on irradiated chicken
NASA Astrophysics Data System (ADS)
Parlato, A.; Calderaro, E.; Bartolotta, A.; D'Oca, M. C.; Giuffrida, S. A.; Brai, M.; Tranchina, L.; Agozzino, P.; Avellone, G.; Ferrugia, M.; Di Noto, A. M.; Caracappa, S.
2007-08-01
Ionizing radiation is widely used as treatment technique for food preservation. It involves among others reduction of microbial contamination, disinfestations, sprout inhibition and extension of shelf life of food. However, the commercialization of irradiated food requires the availability of reliable methods to identify irradiated foodstuffs. In this paper, we present results on the application to irradiated chicken of this method, based on the detection, in muscle and skin samples, of the peaks of ions 98 Da and 112 Da, in a ratio approximately 4:1, typical of radiation induced 2-dodecylcyclobutanones (2-DCB). Aim of the work was also to study the time stability of the measured parameters in samples irradiated at 3 and 5 kGy, and to verify the efficacy of the treatment from a microbiological point of view. Our results show that, one month after irradiation at 3 kGy, the method is suitable using the skin but not the muscle, while the measured parameters are detectable in both samples irradiated at 5 kGy. The microbial population was substantially reduced even at 3 kGy.
Particulate organic acids in the atmosphere of Italian cities: Are they environmentally relevant?
NASA Astrophysics Data System (ADS)
Balducci, Catia; Cecinato, Angelo
2010-02-01
Mono- and dicarboxylic n-alkyl acids were extensively investigated in downtown Rome, Italy, and in Montelibretti, ˜30 km NE of the city, during 2005-2007. Congeners ranging from lauric to mellisic, and from succinic to α,ω-docosanedioic acids were evaluated as well as phthalic, palmitoleic and oleic acids, by solvent extraction of airborne particulates followed by derivatization with propanol in the presence of boron trifluoride, and gas chromatographic-mass spectrometric analysis. Shorter measurements were made in Milan, in Taranto, at suburban and rural sites of Italy, and in the polar regions, from 1996 to 2005. The predominance of palmitic and stearic acids observed elsewhere was confirmed, and the behaviour of azelaic and phthalic acids resulted strongly dependent upon the year season. In the urban sites, among the long-chain compounds, the lignoceric acid was usually the most abundant, while the cerotic, montanic and mellisic homologues cumulatively never exceeded 8% of the total. Unlike other contaminants, the concentrations of organic acids remained fairly invariant over the last decade, suggesting that more attention must be paid to them in the future.
Mechanisms and pathways of aniline elimination from aquatic environments.
Lyons, C D; Katz, S; Bartha, R
1984-01-01
The fate of aniline, a representative of arylamine pollutants derived from the manufacture of dyes, coal liquefaction, and pesticide degradation, was comprehensively evaluated by use of unpolluted and polluted pond water as model environments. Evaporation plus autoxidation proved to be minor elimination mechanisms, removing ca. 1% of the added aniline per day. Instantaneous binding to humic components of a 0.1% sewage sludge inoculum removed 4%. Biodegradation of aniline in pond water was accelerated by the sewage sludge inoculum. A substantial portion of the degraded aniline carbon was mineralized to CO2 within a 1-week period, and microbial biomass was formed as a result of aniline utilization. Biodegradation was clearly the most significant removal mechanism of polluting aniline from pond water. A gas chromatographic-mass spectrometric analysis of biodegradation intermediates revealed that the major pathway of aniline biodegradation in pond water involved oxidative deamination to catechol, which was further metabolized through cis,cis-muconic, beta-ketoadipic, levulinic, and succinic acid intermediates to CO2. Minor biodegradation pathways involved reversible acylation to acetanilide and formanilide, whereas N-oxidation resulted in small amounts of oligomeric condensation products. PMID:6497369
Jeon, Dong Bok; Hong, Young Shin; Lee, Ga Hyun; Park, Yu Min; Lee, Cheong Mi; Nho, Eun Yeong; Choi, Ji Yeon; Jamila, Nargis; Khan, Naeem; Kim, Kyong Su
2017-03-15
Tea contains characteristic volatile organic compounds, polyphenols, caffeine and catechins, and is therefore among the most widely consumed beverages all over the world. In this study, fresh Jukro tea leaves collected from Damyang-gun (Jeollanam-do) at 40, 60 and 90day growth stages, were semi-fermented. The volatile organic compounds (VOCs) were extracted by simultaneous distillation-solvent extraction (SDE) and analyzed by gas chromatography/mass spectrometry (GC/MS). Catechins, caffeine and theanine were analyzed by high performance liquid chromatography (HPLC). A total of 159 VOCs were identified in the analyzed Jukro tea leaves. Comparatively, the increase in the concentrations of VOCs was high in 60day leaves. The content of catechins increased along the three growth stages, whereas caffeine, compared to 90day leaves, was higher for 40 and 60day leaves. Based on the results, the 60day leaves were found to be the most suitable and useful for making semi-fermented Jukro tea. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lebo, Jon A.; Zajicek, James L.; Huckins, James N.; Petty, Jimmie D.; Peterman, Paul H.
1992-01-01
A method is given for the recovery, cleanup, and analysis of polycyclic aromatic hydrocarbons (PAHs) that have been sequestered in SPMDs (semipermeable membrane devices). SPMDs are polymeric membranes enclosing lipids, and mimic the bioconcentration process of aquatic animals. SPMDs are used as passive, in situ monitors of contamination by organic pollutants of aquatic environments. The method reported here includes dialytic recovery of the PAHs, cleanup of the dialysates using size exclusion, adsorption, and argentation chromatographic modules in tandem, then analysis by gas chromatography with photoionization or mass spectrometric detection. The method is demonstrated to overcome the presence of a variety of environmental co-contaminants and other potential interferents in the dialysates. A field application is also demonstrated in which SPMDs are used to monitor PAH contamination in an urban creek. Approaches to the use of SPMD data to calculate aqueous concentrations of PAHs are discussed. The use of SPMDs in combination with the complementary, PAH-specific cleanup procedure provides a unique approach to the analysis of PAH residues in the aquatic environment.
Self-leveling morter as a possible cause of symptoms associated with sick building syndrome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundholm, M.; Lavrell, G.; Mathiasson, L.
In newly constructed houses and buildings in which self-leveling mortar containing casein has been used, residents and office employees have noted a bad odor and have complained of headache, eye and throat irritation, and tiredness. These problems were suspected to result from the degradation products emitted from the mortar. Samples obtained from dry mortar powder and from mortar in buildings where casein was used and from control buildings were found to contain microorganisms (mean of 10{sup 2} culture forming units/g). Environmental species were predominantly found, e.g., Bacillus, Clostridium, Micrococcus, and Propionibacterium. Fungi were found occasionally; no evidence of bacterial degradationmore » was found. Headspace and gas chromatographic-mass spectrometric analysis of air from the newly constructed houses and from hydroxide-degraded casein revealed the presence of amines in the 0.003-0.013 ppm range and the presence of ammonia and sulfhydryl compounds, all of which in low concentrations can cause the symptoms observed. These substances, however, were not detected in control buildings.« less
Iterated reaction graphs: simulating complex Maillard reaction pathways.
Patel, S; Rabone, J; Russell, S; Tissen, J; Klaffke, W
2001-01-01
This study investigates a new method of simulating a complex chemical system including feedback loops and parallel reactions. The practical purpose of this approach is to model the actual reactions that take place in the Maillard process, a set of food browning reactions, in sufficient detail to be able to predict the volatile composition of the Maillard products. The developed framework, called iterated reaction graphs, consists of two main elements: a soup of molecules and a reaction base of Maillard reactions. An iterative process loops through the reaction base, taking reactants from and feeding products back to the soup. This produces a reaction graph, with molecules as nodes and reactions as arcs. The iterated reaction graph is updated and validated by comparing output with the main products found by classical gas-chromatographic/mass spectrometric analysis. To ensure a realistic output and convergence to desired volatiles only, the approach contains a number of novel elements: rate kinetics are treated as reaction probabilities; only a subset of the true chemistry is modeled; and the reactions are blocked into groups.
Low pressure gas flow analysis through an effusive inlet using mass spectrometry
NASA Technical Reports Server (NTRS)
Brown, David R.; Brown, Kenneth G.
1988-01-01
A mass spectrometric method for analyzing flow past and through an effusive inlet designed for use on the tethered satellite and other entering vehicles is discussed. Source stream concentrations of species in a gaseous mixture are determined using a calibration of measured mass spectral intensities versus source stream pressure for standard gas mixtures and pure gases. Concentrations are shown to be accurate within experimental error. Theoretical explanations for observed mass discrimination effects as they relate to the various flow situations in the effusive inlet and the experimental apparatus are discussed.
Bonaduce, I; Colombini, M P; Degano, I; Di Girolamo, F; La Nasa, J; Modugno, F; Orsini, S
2013-01-01
The molecular structure of three low-molecular-weight resins used as paint varnishes has been characterized by use of an approach based on three different mass spectrometric techniques. We investigated the ketone resin MS2A, the aldehyde resin Laropal A81, and the hydrocarbon resin Regalrez 1094, now commonly used in restoration. To date, the molecular structures of these resins have not been completely elucidated. To improve current knowledge of the chemical composition of these materials, information obtained by gas chromatography-mass spectrometry (GC/MS), pyrolysis-gas chromatography-mass spectrometry (Py/GC/MS), and electrospray ionization mass spectrometry (ESI-Q-ToF) was combined. Analysis, in solution, of the whole polymeric fraction of the resins by flow-injection ESI-Q-ToF, and of the non-polymeric fraction by GC-MS, enabled us to identify previously unreported features of the polymer structures. In addition, the Py-GC/MS profiles that we obtained will help to enhance the databases currently available in the literature. The proposed approach can be extended to other low-molecular-weight resins used as varnishes in conservation.
USDA-ARS?s Scientific Manuscript database
In the present work multiple component isolation from the oil of Crinitaria tatarica (Less.) Sojak. by Preparative Capillary Gas Chromatography (PCGC) with characterization by mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy have been carried out. Gas chromatography (GC-FID) ...
Konda, Ravi Kumar; Chandu, Babu Rao; Challa, B.R.; Kothapalli, Chandrasekhar B.
2012-01-01
The most suitable bio-analytical method based on liquid–liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm×50 mm, 3.5 μm) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The total run time was 3.0 min. The proposed method has been validated with the linear range of 5–12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3%–2.9% and 1.6%–2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. PMID:29403764
NASA Technical Reports Server (NTRS)
Lewis, B. W.; Brown, K. G.; Wood, G. M., Jr.; Puster, R. L.; Paulin, P. A.; Fishel, C. E.; Ellerbe, D. A.
1986-01-01
Knowledge of test gas composition is important in wind-tunnel experiments measuring aerothermodynamic interactions. This paper describes measurements made by sampling the top of the test section during runs of the Langley 7-Inch High-Temperature Tunnel. The tests were conducted to determine the mixing of gas injected from a flat-plate model into a combustion-heated hypervelocity test stream and to monitor the CO2 produced in the combustion. The Mass Spectrometric (MS) measurements yield the mole fraction of N2 or He and CO2 reaching the sample inlets. The data obtained for several tunnel run conditions are related to the pressures measured in the tunnel test section and at the MS ionizer inlet. The apparent distributions of injected gas species and tunnel gas (CO2) are discussed relative to the sampling techniques. The measurements provided significant real-time data for the distribution of injected gases in the test section. The jet N2 diffused readily from the test stream, but the jet He was mostly entrained. The amounts of CO2 and Ar diffusing upward in the test section for several run conditions indicated the variability of the combustion-gas test-stream composition.
NASA Astrophysics Data System (ADS)
Schoenmakers, Peter
2009-07-01
This review focuses on the chromatography research that has been carried out within industry or in close cooperation with industry and that has been reported in the scientific literature between 2006 and mid-2008. Companies in the health care sector, such as pharmaceutical and biotechnology companies, are the largest contributors. Industrial research seems to take place in an open environment in cooperation with academia, peer companies, and institutions. Industry appears ready to embrace new technologies as they emerge, but they focus strongly on making chromatography work robustly, reliably, rapidly, and automatically. “Hyphenated” systems that incorporate on-line sample-preparation techniques and mass-spectrometric detection are the rule rather than the exception. Various multidimensional separation methods are finding numerous applications. Strategies aimed at speeding up the development of new chromatographic methods remain the focus of attention. Also, there is a clear trend toward exploring chromatographic methods for parallel processing along with other strategies for high-throughput analysis.
Toward a Micro Gas Chromatograph/Mass Spectrometer (GC/MS) System
NASA Technical Reports Server (NTRS)
Wiberg, D. V.; Eyre, F. B.; Orient, O.; Chutjian, A.; Garkarian, V.
2001-01-01
Miniature mass filters (e.g., quadrupoles, ion traps) have been the subject of several miniaturization efforts. A project is currently in progress at JPL to develop a miniaturized Gas Chromatograph/Mass Spectrometer (GC/MS) system, incorporating and/or developing miniature system components including turbomolecular pumps, scroll type roughing pump, quadrupole mass filter, gas chromatograph, precision power supply and other electronic components. The preponderance of the system elements will be fabricated using microelectromechanical systems (MEMS) techniques. The quadrupole mass filter will be fabricated using an X-ray lithography technique producing high precision, 5x5 arrays of quadrupoles with pole lengths of about 3 mm and a total volume of 27 cubic mm. The miniature scroll pump will also be fabricated using X-ray lithography producing arrays of scroll stages about 3 mm in diameter. The target detection range for the mass spectrometer is 1 to 300 atomic mass units (AMU) with are solution of 0.5 AMU. This resolution will allow isotopic characterization for geochronology, atmospheric studies and other science efforts dependant on the understanding of isotope ratios of chemical species. This paper will discuss the design approach, the current state-of-the art regarding the system components and the progress toward development of key elements. The full system is anticipated to be small enough in mass, volume and power consumption to allow in situ chemical analysis on highly miniaturized science craft for geochronology, atmospheric characterization and detection of life experiments applicable to outer planet roadmap missions.
Schänzer, W; Donike, M
1992-01-01
Urinary metabolites of boldenone (androsta-1,4-dien-17 beta-ol-3-one) following oral administration of boldenone (doses from 11 to 80 mg) to man were isolated from urine via XAD-2 adsorption and enzymatic hydrolysis with beta-glucuronidase from Escherichia coli. The isolated metabolites were derivatized with N-methyl-N-trimethylsilyltri- fluoroacetamide/trimethyliodosilane and analysed by gas chromatography/mass spectrometry with electron impact (EI) ionization at 70 eV. Boldenone (I) and four metabolites were identified after hydrolysis of the urine with beta-glucuronidase: 5 beta-androst-1-en-17 beta-ol-3-one (II), 5 beta-androst-1-ene-3 alpha, 17 beta-diol (III), 5 beta-androst-1-en-3 alpha-ol-17-one (IV) and 5 beta-androst-1-en-6 beta-ol-3,17-dione (V). Five further metabolites in low concentration were identified without enzymatic hydrolysis after treatment of the urine with potassium carbonate: 5 beta-androst-1-ene-3,17-dione (VI), 5 alpha-androst-1-ene-3,17-dione (VII), androsta-1,4-diene-3,17-dione (VIII), androsta-1,4-diene-6 beta,17 beta-diol-3-one (IX) and androsta-1,4-dien-6 beta-ol-3,17-dione (X). The identification of the metabolites is based on the gas chromatography retention index, high-performance liquid chromatography retention, EI mass spectrum, chemical reactions of the isolated metabolites, and synthesis of metabolites II, III, IV, VI and VII. The EI mass spectra of the bis-trimethylsilyl derivatives of boldenone and its metabolites display all intense molecular ions, M-15 ions and fragment ions originating from cleavage of the B-ring. The excreted metabolites can be separated in basic extractable labile conjugates and in stable conjugates. More than 95% of metabolites are excreted as stable conjugates.
An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide
NASA Technical Reports Server (NTRS)
Gregory, Gerald L.; Davis, Douglas D.; Beltz, Nobert; Bandy, Alan R.; Ferek, Ronald J.; Thornton, Donald C.
1993-01-01
As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.
Mass spectrometer vacuum housing and pumping system
Coutts, G.W.; Bushman, J.F.; Alger, T.W.
1996-07-23
A vacuum housing and pumping system is described for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof. 7 figs.
Mass spectrometer vacuum housing and pumping system
Coutts, Gerald W.; Bushman, John F.; Alger, Terry W.
1996-01-01
A vacuum housing and pumping system for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof.
Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection
Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan
2011-01-01
Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O2 content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. PMID:21497566
Clinical applications of gas chromatograph/mass spectrometer/computer systems.
Horning, M G; Nowlin, J; Butler, C M; Lertratanangkoon, K; Sommer, K; Hill, R M
1975-08-01
Gas chromatograph/mass spectrometer/computer systems can be used to quantify a wide variety of compounds of clinical interest. A quadrupole instrument operated in the chemical ionization (Cl) mode was used in these studies. Because of the sensitivity and specificity of selective ion detection, it is possible to make measurements routinely in the nanogram to picogram range, with 0.1-1.0 ml samples of plasma and 1-5 ml samples or urine. Internal standards, preferably stable-isotope-labeled compounds, were added to the biological samples before isolation was begun. We describe clinical applications of these procedures to problems in toxicology, pharmacokinetics, and perinatal pharmacology.
NASA Astrophysics Data System (ADS)
Qi, Yulin; Müller, Miriam; Stokes, Caroline S.; Volmer, Dietrich A.
2018-04-01
LC-MS/MS is widely utilized today for quantification of vitamin D in biological fluids. Mass spectrometric assays for vitamin D require very careful method optimization for precise and interference-free, accurate analyses however. Here, we explore chemical derivatization and matrix-assisted laser desorption/ionization (MALDI) as a rapid alternative for quantitative measurement of 25-hydroxyvitamin D3 in human serum, and compare it to results from LC-MS/MS. The method implemented an automated imaging step of each MALDI spot, to locate areas of high intensity, avoid sweet spot phenomena, and thus improve precision. There was no statistically significant difference in vitamin D quantification between the MALDI-MS/MS and LC-MS/MS: mean ± standard deviation for MALDI-MS—29.4 ± 10.3 ng/mL—versus LC-MS/MS—30.3 ± 11.2 ng/mL (P = 0.128)—for the sum of the 25-hydroxyvitamin D epimers. The MALDI-based assay avoided time-consuming chromatographic separation steps and was thus much faster than the LC-MS/MS assay. It also consumed less sample, required no organic solvents, and was readily automated. In this proof-of-concept study, MALDI-MS readily demonstrated its potential for mass spectrometric quantification of vitamin D compounds in biological fluids.
Shunji, Hashimoto; Yoshikatsu, Takazawa; Akihiro, Fushimi; Hiroyasu, Ito; Kiyoshi, Tanabe; Yasuyuki, Shibata; Masa-aki, Ubukata; Akihiko, Kusai; Kazuo, Tanaka; Hideyuki, Otsuka; Katsunori, Anezaki
2008-01-18
Polychlorinated dibenzo-p-dioxins and dibenzofurans in crude extracts of fly ash and flue gas from municipal waste incinerators were quantified using a comprehensive multidimensional gas chromatograph (GC x GC) coupled to a high-resolution time-of-flight mass spectrometer (HR-TOFMS). For identification and quantification, we developed our own program to prepare 3D chromatograms of selected mass numbers from the data of the GC x GC/HR-TOFMS. Isolation of all congeners with a TCDD toxic equivalency factor from the other isomers by only one injection was confirmed. The instrumental detection limit of TCDD on the GC x GC/HR-TOFMS was 0.9 pg by the relative calibration method. Quantification of these substances in the crude extracts was achieved by direct injection to the GC x GC/HR-TOFMS. The results agree with the values obtained using a generic gas chromatography/high-resolution mass spectrometry (GC/HRMS) system. It was confirmed that measurement by high-resolution TOFMS and GC x GC effectively reduces interference from other chemicals.
Reichenbach, Stephen E; Kottapalli, Visweswara; Ni, Mingtian; Visvanathan, Arvind
2005-04-15
This paper describes a language for expressing criteria for chemical identification with comprehensive two-dimensional gas chromatography paired with mass spectrometry (GC x GC-MS) and presents computer-based tools implementing the language. The Computer Language for Indentifying Chemicals (CLIC) allows expressions that describe rules (or constraints) for selecting chemical peaks or data points based on multi-dimensional chromatographic properties and mass spectral characteristics. CLIC offers chromatographic functions of retention times, functions of mass spectra, numbers for quantitative and relational evaluation, and logical and arithmetic operators. The language is demonstrated with the compound-class selection rules described by Welthagen et al. [W. Welthagen, J. Schnelle-Kreis, R. Zimmermann, J. Chromatogr. A 1019 (2003) 233-249]. A software implementation of CLIC provides a calculator-like graphical user-interface (GUI) for building and applying selection expressions. From the selection calculator, expressions can be used to select chromatographic peaks that meet the criteria or create selection chromatograms that mask data points inconsistent with the criteria. Selection expressions can be combined with graphical, geometric constraints in the retention-time plane as a powerful component for chemical identification with template matching or used to speed and improve mass spectrum library searches.
Remane, Daniela; Wissenbach, Dirk K; Meyer, Markus R; Maurer, Hans H
2010-04-15
In clinical and forensic toxicology, multi-analyte procedures are very useful to quantify drugs and poisons of different classes in one run. For liquid chromatographic/tandem mass spectrometric (LC/MS/MS) multi-analyte procedures, often only a limited number of stable-isotope-labeled internal standards (SIL-ISs) are available. If an SIL-IS is used for quantification of other analytes, it must be excluded that the co-eluting native analyte influences its ionization. Therefore, the effect of ion suppression and enhancement of fourteen SIL-ISs caused by their native analogues has been studied. It could be shown that the native analyte concentration influenced the extent of ion suppression and enhancement effects leading to more suppression with increasing analyte concentration especially when electrospray ionization (ESI) was used. Using atmospheric-pressure chemical ionization (APCI), methanolic solution showed mainly enhancement effects, whereas no ion suppression and enhancement effect, with one exception, occurred when plasma extracts were used under these conditions. Such differences were not observed using ESI. With ESI, eleven SIL-ISs showed relevant suppression effects, but only one analyte showed suppression effects when APCI was used. The presented study showed that ion suppression and enhancement tests using matrix-based samples of different sources are essential for the selection of ISs, particularly if used for several analytes to avoid incorrect quantification. In conclusion, only SIL-ISs should be selected for which no suppression and enhancement effects can be observed. If not enough ISs are free of ionization interferences, a different ionization technique should be considered. 2010 John Wiley & Sons, Ltd.
Sardela, V F; Deventer, K; Pereira, H M G; de Aquino Neto, F R; Van Eenoo, P
2012-11-01
Formoterol is a long acting β(2)-agonist and has proven to be a very effective bronchodilating agent. Hence it is frequently applied therapeutically for the treatment of asthma. Because β(2)-agonists might be misused in sports for the stimulatory effects and for growth-promoting action their use is restricted. Since January 2012, formoterol is prohibited in urinary concentrations higher than 30 ng/mL. The objective of this study was to develop and validate a simple and robust ultra high performance liquid chromatographic-tandem mass spectrometric (UHPLC-MS/MS) method for the direct quantification of formoterol in urine. Sample preparation was limited to an enzymatic hydrolysis step after which 2 μL was injected in the chromatographic system. Chromatography was performed on a C(8)-column using gradient conditions. The mobile phase consisted of water/methanol (H(2)O/MeOH) both containing 0.1% acetic acid (HOAc) and 1mM ammonium acetate (NH(4)OAc). Calibration curve were constructed between 15 and 60 ng/mL. Validation data showed bias of 1.3% and imprecision of 5.4% at the threshold. Ion suppression/enhancement never exceeded 7%. Calculating measurement uncertainty showed proof of applicability of the method. Stability of formoterol was also investigated at 56 °C (accelerated stability test) at pH 1.0/5.2/7.0 and 9.5. At the physiological pH values of 5.2 and 7.0, formoterol showed good stability. At pH 1.0 and 9.5 significant degradation was observed. Copyright © 2012 Elsevier B.V. All rights reserved.
Lung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas
NASA Astrophysics Data System (ADS)
Wehinger, Andreas; Schmid, Alex; Mechtcheriakov, Sergei; Ledochowski, Maximilian; Grabmer, Christoph; Gastl, Guenther A.; Amann, Anton
2007-08-01
Background Determination of the diagnostic usefulness of proton transfer reaction mass spectrometry (PTR-MS) for detecting primary lung cancer through analysis of volatile organic compounds (VOCs) in exhaled human breath was demonstrated in this investigation. Unlike, for example, gas-chromatographic analyses, PTR-MS can be used without time-consuming preconcentration of the gas samples.Methods By means of PTR-MS, exhaled breath samples from primary lung cancer patients (n = 17) were analyzed and compared with both an overall control collective (controls total, n = 170) and three sub-collectives: hospital personnel (controls hospital, n = 35), age-matched persons (controls age, n = 25), and smokers (controls s, n = 60), respectively.Results Among the VOCs present at reasonably high concentrations, the ones leading to the product ion at m/z = 31 (VOC-31, tentatively protonated formaldehyde) and m/z = 43 (VOC-43, tentatively a fragment of protonated iso-propanol), were found at significantly higher concentrations in the breath gas of the primary lung cancer patients as compared to the healthy controls at the following median concentrations (with interquartile distance, iqr): For VOC-31 the median concentrations were 7.0 ppb (iqr, 15.5 ppb) versus 3.0 ppb (iqr, 1.9 ppb) with P < 10-4. For VOC-43 the median concentrations were 244.1 ppb (iqr, 236.2 ppb) versus 94.1 ppb (iqr, 55.2 ppb) with P < 10-6. The discriminative power between the two collectives was further assessed by ROC-curves obtained upon variation of the chosen threshold concentration and by Fisher's Quadratic Discriminant Method.Conclusions Within the limits of pilot study, VOC-31 and -43 were found to best discriminate between exhaled breath of primary lung cancer cases and healthy controls. Simple and time-saving breath gas analysis by PTR-MS makes this method attractive for a larger clinical evaluation. It may become a new valuable tool for diagnosing primary lung cancer.
Reichel, W.L.; Kolbe, E.J.; Stafford, C.J.
1981-01-01
A procedure is described for determining fenvalerate and permethrin residues in grasshoppers and duck tissues. Samples are Soxhlet-extracted with hexane and cleaned up by gel permeation chromatography with an in-line alumina column. Samples are analyzed by gas-liquid chromatography with electron capture detection, and confirmed by gas-liquid chromatography-mass spectrometry. The average recovery from fortified tissues was 97%.
A nonlinear model for gas chromatograph systems
NASA Technical Reports Server (NTRS)
Feinberg, M. P.
1975-01-01
Fundamental engineering design techniques and concepts were studied for the optimization of a gas chromatograph-mass spectrometer chemical analysis system suitable for use on an unmanned, Martian roving vehicle. Previously developed mathematical models of the gas chromatograph are found to be inadequate for predicting peak heights and spreading for some experimental conditions and chemical systems. A modification to the existing equilibrium adsorption model is required; the Langmuir isotherm replaces the linear isotherm. The numerical technique of Crank-Nicolson was studied for use with the linear isotherm to determine the utility of the method. Modifications are made to the method eliminate unnecessary calculations which result in an overall reduction of the computation time of about 42 percent. The Langmuir isotherm is considered which takes into account the composition-dependent effects on the thermodynamic parameter, mRo.
The gas chromatographic (GC) and Fourier transform infrared and mass spectroscopic (FT-IR and MS, respectively) properties of (Z)-2-chloro-3-(dichloromethyl)4-oxobutenoic acid (MX) (a highly mutagenic byproduct of drinking water chlorination) and several related compounds were st...
Paleogene stratigraphy of the Solomons Island, Maryland corehole
Gibson, Thomas G.; Bybell, Laurel M.
1994-01-01
Purge and trap capillary gas chromatography/mass spectrometry is a rapid, precise, accurate method for determining volatile organic compounds in samples of surface water and ground water. The method can be used to determine 59 selected compounds, including chlorofluorohydrocarbons, aromatic hydrocarbons, and halogenated hydrocarbons. The volatile organic compounds are removed from the sample matrix by actively purging the sample with helium. The volatile organic compounds are collected onto a sorbant trap, thermally desorbed, separated by a Megabore gas chromatographic capillary column, ionized by electron impact, and determined by a full-scan quadrupole mass spectrometer. Compound identification is confirmed by the gas chromatographic retention time and by the resultant mass spectrum. Unknown compounds detected in a sample can be tentatively identified by comparing the unknown mass spectrum to reference spectra in the mass-spectra computer-data system library compiled by the National Institute of Standards and Technology. Method detection limits for the selected compounds range from 0.05 to 0.2 microgram per liter. Recoveries for the majority of the selected compounds ranged from 80 to 120 percent, with relative standard deviations of less than 10 percent.
ANALYSIS OF POLYCYCLIC AROMATIC HYDROCARBONS BY ION TRAP TANDEM MASS SPECTROMETRY
An ion-trap mass spectrometer with a wave board and tandem mass spectrometry software was used to analyze gas chromatographically separated polycyclic aromatic hydrocarbons (PAHs) by using collision-induced dissociation (CID). The nonresonant (multiple collision) mode was used to...
NASA Astrophysics Data System (ADS)
Goldan, P. D.; Kuster, W. C.; Williams, E.; Fehsenfeld, F. C.
2003-12-01
During the NEAQS 2002 study, in-situ NMHC measurements were made aboard the NOAA research vessel Ronald H. Brown by a two channel automated gas chromatograph using both flame ionization and mass-spectrometric detection techniques. Five minute average samples were cryogenically trapped each 1/2 hour and analyzed immediately for C2 through C10 alkanes, C2 through C5 alkenes, C6 through C9 aromatics, C2 through C8 aldehydes and ketones, C1 through C5 alcohols and a variety of compounds of biogenic origin including 6 monoterpenes, isoprene and its primary oxidation products methacrolein and methylvinyl ketone. The relative contributions of these classes of compounds to OH photochemistry has been determined for air masses ranging from those showing significant anthropogenic influence to clean marine air. For the most anthropogenically influenced air masses, alkenes were observed to play a dominant role whereas oxy-hydrocarbons, principally acetaldehyde, were observed to dominate under clean marine conditions. Both the NMHC measurements and back trajectory analyses indicated periods of significant influx into the New England coastal region of urban air masses showing elevated ozone levels from the Boston/Providence urban corridor. About as frequently, less photochemically mature air masses, depleted in ozone but laden with light reactive alkenes, were observed coming from the Portsmouth NH/Kittery ME coastal urban complex. Even in the presence of these anthropogenic plumes, biogenic hydrocarbons appear to dominate OH photochemistry in the New England region much of the time. Data demonstrating all of these conclusions will be shown.
Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection.
Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan
2011-06-01
Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O(2) content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. Copyright © 2011 Elsevier B.V. All rights reserved.
LC–MS/MS determination of carbamathione in microdialysis samples from rat brain and plasma
Kaul, Swetha; Williams, Todd D.; Lunte, Craig E.; Faiman, Morris D.
2009-01-01
A selective liquid chromatography–tandem mass spectrometric (LC–MS/MS) method was developed for the determination of S-(N, N-diethylcarbamoyl) glutathione (carbamathione) in microdialysis samples from rat brain and plasma. S-(N, N-Diethylcarbamoyl) glutathione (carbamathione) is a metabolite of disulfiram. This metabolite may be responsible for disulfiram’s effectiveness in the treatment of cocaine dependence. An analytical method using liquid chromatography–tandem mass spectrometric (LC–MS/MS) was developed to determine carbamathione in vivo using microdialysis sampling from rat brain and plasma. Chromatographic separations were carried out on an Alltech Altima C-18 (50 mm long × 2.1 mm i.d., 3 μm particles) analytical column at a flow rate of 0.3 ml/min. Solvent A consisted of 10 mM ammonium formate, methanol, and formic acid (99:1:0.06, v/v/v). Solvent B consisted of methanol, 10 mM ammonium formate and formic acid (99:1:0.06, v/v/v). A 20 min linear gradient from 95% aqueous to 95% organic was used. Tandem mass spectra were acquired on a Micromass Quattro Ultima “triple” quadrupole mass spectrometer equipped with an ESI interface. Quantitative mass spectrometric analysis was conducted in positive ion mode selected reaction monitoring (SRM) mode looking at the transition of m/z 407–100 and 175 for carbamathione and m/z 392–263 for the internal standard S-hexyl glutathione. The simultaneous collection of microdialysate from blood and brain was used to monitor carbamathione concentrations centrally and peripherally. Good linearity was obtained over a concentration range of 0.25–10,000 nM. The lowest limit of quantification (LLOQ) was determined to be 1 nM and the lowest limit of detection (LLOD) was calculated to be 0.25 nM. Intra- and inter-day accuracy and precision were determined and for all the samples evaluated, the variability was less that 10% (R.S.D.). PMID:19709836
Mass spectrometric detection of peginesatide in human urine in doping control analysis.
Möller, Ines; Thomas, Andreas; Delahaut, Philippe; Geyer, Hans; Schänzer, Wilhelm; Thevis, Mario
2012-11-01
Erythropoiesis-stimulating agents (ESAs) have frequently been confessed to be illicitly used in elite sports due to their endurance enhancing effects. Recently, peginesatide, the first representative of a new generation of ESAs, referred to as Erythropoietin (EPO)-mimetic peptides, obtained approval in the USA under the trade name Omontys(®) for the treatment of anaemic patients. Lacking sequence homology with EPO, it consists of a pegylated homodimeric peptide of approximately 45 kDa, and thus, specific approaches for the determination of peginesatide in blood were developed as conventional detection assays for EPO do not allow for the analysis of the EPO-mimetic peptides. However, as urine specimens are the most frequently provided doping control samples and pharmacokinetic studies conducted in rats and monkeys revealed the excretion of the pegylated peptide into urine, a detection method for peginesatide in urine would be desirable. A mass spectrometric assay in human urine was developed consisting of protein precipitation with acetonitrile followed by proteolytic digestion after the removal of the acetonitrile fraction under reduced pressure. Purification and concentration of the resulting proteotypic target peptide was accomplished by means of solid-phase extraction on strong cation-exchange resin prior to liquid chromatographic-tandem mass spectrometric analysis. Method validation was performed for qualitative purposes and demonstrated specificity, precision, linearity as well as sufficient sensitivity (limit of detection: 0.5 ng/ml) while proof-of-concept for the applicability of the assay for the determination of peginesatide in authentic urine samples was obtained by analyzing animal in vivo specimens collected after a single i.v. administration of peginesatide over a period of 4 days. Copyright © 2012 Elsevier B.V. All rights reserved.
Taguchi, Vince Y; Nieckarz, Robert J; Clement, Ray E; Krolik, Stefan; Williams, Robert
2010-11-01
The feasibility of utilizing a gas chromatograph-tandem quadrupole-Fourier transform ion cyclotron resonance mass spectrometer (GC-MS/MS-FTICRMS) to analyze chlorinated-dioxins/furans (CDDs/CDFs) and mixed halogenated dioxins/furans (HDDs/HDFs) was investigated by operating the system in the GC-FTICRMS mode. CDDs/CDFs and mixed HDDs/HDFs could be analyzed at 50,000 to 100,000 resolving power (RP) on the capillary gas chromatographic time scale. Initial experiments demonstrated that 1 pg of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and 5 pg of 2-bromo-3,7,8-trichlorodibenzo-p-dioxin (BTrCDD) could be detected. The feasibility of utilizing an FTICRMS for screening of CDDs/CDFs, HDDs/HDFs and related compounds was also investigated by analyzing an extract from vegetation exposed to fall-out from an industrial fire. CDDs/CDFs, chlorinated pyrenes and chlorinated tetracenes could be detected from a Kendrick plot analysis of the ultrahigh resolution mass spectra. Mass accuracies were of the order of 0.5 ppm on standards with external mass calibration and 1 ppm on a sample with internal mass calibration. Copyright © 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.
Analysis of poly-beta-hydroxybutyrate in environmental samples by GC-MS/MS.
Elhottová, D; Tríska, J; Petersen, S O; Santrůcková, H
2000-05-01
Application of gas chromatography-mass spectrometry (GC-MS) can significantly improve trace analyses of compounds in complex matrices from natural environments compared to gas chromatography only. A GC-MS/MS technique for determination of poly-beta-hydroxybutyrate (PHB), a bacterial storage compound, has been developed and used for analysis of two soils stored for up to 319 d, fresh samples of sewage sludge, as well as a pure culture of Bacillus megaterium. Specific derivatization of beta-hydroxybutyrate (3-OH C4:0) PHB monomer units by N-tert-butyl-dimethylsilyl-N-methyltrifluoracetamide (MTBSTFA) improved chromatographic and mass spectrometric properties of the analyte. The diagnostic fragmentation scheme of the derivates tert-butyldimethylsilyl ester and ether of beta-hydroxybutyric acid (MTBSTFA-HB) essential for the PHB identification was shown. The ion trap MS was used, therefore the scan gave the best sensitivity and with MS/MS the noise decreased, so the S/N was better and also with second fragmentation the amount of ions increased compared to SIM. The detection limit for MTBSTFA-HB by GC-MS/MS was about 10(-13) g microL(-1) of injected volume, while by GC (FID) and GC-MS (scan) it was around 10(-10) g microL(-1) of injected volume. Sensitivity of GC-MS/MS measurements of PHB in arable soil and activated sludge samples was down to 10 pg of PHB g(-1) dry matter. Comparison of MTBSTFA-HB detection in natural soil sample by GC (FID), GC-MS (scan) and by GC-MS/MS demonstrated potentials and limitations of the individual measurement techniques.
LipidPioneer: A Comprehensive User-Generated Exact Mass Template for Lipidomics
Ulmer, Candice Z.; Koelmel, Jeremy P.; Ragland, Jared M.; Garrett, Timothy J.
2017-01-01
Lipidomics, the comprehensive measurement of lipid species in a biological system, has promising potential in biomarker discovery and disease etiology elucidation. Advances in chromatographic separation, mass spectrometric techniques, and novel substrate applications continue to expand the number of lipid species observed. The total number and type of lipid species detected in a given sample are generally indicative of the sample matrix examined (e.g. serum, plasma, cells, bacteria, tissue, etc.). Current exact mass lipid libraries are static and represent the most commonly analyzed matrices. It is common practice for users to manually curate their own lists of lipid species and adduct masses; however, this process is time-consuming. LipidPioneer, an interactive template, can be used to generate exact masses and molecular formulas of lipid species that may be encountered in the mass spectrometric analysis of lipid profiles. Over 60 lipid classes are present in the LipidPioneer template, and include several unique lipid species, such as ether-linked lipids and lipid oxidation products. In the template, users can add any fatty acyl constituents without limitation in the number of carbons or degrees of unsaturation. LipidPioneer accepts naming using the lipid class level (sum composition) and the LIPID MAPS notation for fatty acyl structure level. In addition to lipid identification, user generated lipid m/z values can be used to develop inclusion lists for targeted fragmentation experiments. Resulting lipid names and m/z values can be imported into software such as MZmine or Compound Discoverer to automate exact mass searching and isotopic pattern matching across experimental data. PMID:28074328
Karasali, Helen; Kasiotis, Konstantinos M; Machera, Kyriaki; Ambrus, Arpad
2014-11-26
Counterfeit pesticides threaten public health, food trade, and the environment. The present work draws attention to the importance of regular monitoring of impurities in formulated pesticide products. General screening revealed the presence of carbaryl as a contaminant in a copper oxychloride formulated product. In this paper, as a case study, a liquid chromatographic diode array-mass spectrometric method developed for general screening of pesticide products and quantitative determination of carbaryl together with its validation is presented. The proposed testing strategy is considered suitable for use as a general approach for testing organic contaminants and impurities in solid pesticide formulations.
Cavalli, Silvano; Polesello, Stefano; Valsecchi, Sara
2005-08-26
Bromate, a well known by-product of the ozonation of drinking water, has been included among the substances which have to be monitored in the drinking water according to the last EC Directive 251/98 on potable water with a regulated limit of 10 microg l(-1). The need of performing routine analysis at this limit is a driving force for the developing of new simple and sensitive methods of detection, which should be also able to overcome the effect of matrix composition. This work explored the use of mass spectrometry detection with electrospray ionisation hyphenated to a reagent free ion chromatograph with hydroxide gradient elution for the determination of bromate in drinking water. The use of a high capacity hydroxide selective column operated in gradient mode allowed to avoid the interference by carbonate peak, which moved to longer retention times. The effect of increasing chloride concentrations from 0 to 250 mg l(-1), which is the guideline limit for drinking water in Directive 251/98/EC, was to decrease absolute mass spectrometric response and chromatographic efficiency and, on the consequence, to increase the effective detection limits. The effect of the chloride concentration on the detection of bromate is discussed.
Salama, Nahla N; Wang, Shudong
2008-05-28
The present study employs time of flight mass and bupivacaine in authentic, pharmaceutical and spiked human plasma as well as in the presence of their impurities 2,6-dimethylaniline and alkaline degradation product. The method is based on time of flight electron spray ionization mass spectrometry technique without preliminary chromatographic separation and makes use of bupivacaine as internal standard for ropivacaine, which is used as internal standard for bupivacaine. A linear relationship between drug concentrations and the peak intensity ratio of ions of the analyzed substances is established. The method is linear from 23.8 to 2380.0 ng mL(-1) for both drugs. The correlation coefficient was >or=0.996 in authentic and spiked human plasma. The average percentage recoveries in the ranges of 95.39%-102.75% was obtained. The method is accurate (% RE < 5%) and reproducible with intra- and inter-assay precision (RSD% < 8.0%). The quantification limit is 23.8 ng mL(-1) for both drugs. The method is not only highly sensitive and selective, but also simple and effective for determination or identification of both drugs in authentic and biological fluids. The method can be applied in purity testing, quality control and stability monitoring for the studied drugs.
Salama, Nahla N.; Wang, Shudong
2009-01-01
The present study employs time of flight mass and bupivacaine in authentic, pharmaceutical and spiked human plasma as well as in the presence of their impurities 2,6-dimethylaniline and alkaline degradation product. The method is based on time of flight electron spray ionization mass spectrometry technique without preliminary chromatographic separation and makes use of bupivacaine as internal standard for ropivacaine, which is used as internal standard for bupivacaine. A linear relationship between drug concentrations and the peak intensity ratio of ions of the analyzed substances is established. The method is linear from 23.8 to 2380.0 ng mL−1 for both drugs. The correlation coefficient was ≥0.996 in authentic and spiked human plasma. The average percentage recoveries in the ranges of 95.39%–102.75% was obtained. The method is accurate (% RE < 5%) and reproducible with intra- and inter-assay precision (RSD% < 8.0%). The quantification limit is 23.8 ng mL−1 for both drugs. The method is not only highly sensitive and selective, but also simple and effective for determination or identification of both drugs in authentic and biological fluids. The method can be applied in purity testing, quality control and stability monitoring for the studied drugs. PMID:19652756
Label-assisted mass spectrometry for the acceleration of reaction discovery and optimization
NASA Astrophysics Data System (ADS)
Cabrera-Pardo, Jaime R.; Chai, David I.; Liu, Song; Mrksich, Milan; Kozmin, Sergey A.
2013-05-01
The identification of new reactions expands our knowledge of chemical reactivity and enables new synthetic applications. Accelerating the pace of this discovery process remains challenging. We describe a highly effective and simple platform for screening a large number of potential chemical reactions in order to discover and optimize previously unknown catalytic transformations, thereby revealing new chemical reactivity. Our strategy is based on labelling one of the reactants with a polyaromatic chemical tag, which selectively undergoes a photoionization/desorption process upon laser irradiation, without the assistance of an external matrix, and enables rapid mass spectrometric detection of any products originating from such labelled reactants in complex reaction mixtures without any chromatographic separation. This method was successfully used for high-throughput discovery and subsequent optimization of two previously unknown benzannulation reactions.
The use of mass spectrometry to analyze dried blood spots.
Wagner, Michel; Tonoli, David; Varesio, Emmanuel; Hopfgartner, Gérard
2016-01-01
Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to sample preparation and will consider off-line and on-line extractions; in particular, instrumental designs that have been developed so far for DBS extraction will be detailed. Flow injection analysis and applications will be discussed in section IV. The application of surface analysis mass spectrometry (DESI, paper spray, DART, APTDCI, MALDI, LDTD-APCI, and ICP) to DBS is described in section V, while applications based on separation techniques (e.g., liquid or gas chromatography) are presented in section VI. To conclude this review, the current status of DBS analysis is summarized, and future perspectives are provided. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Unelius, C. R.; Park, K.-C.; McNeill, M.; Wee, S. L.; Bohman, B.; Suckling, D. M.
2013-02-01
An investigation to identify a sex or aggregation pheromone of Sitona discoideus Gyllenhål (Coleoptera: Curculionidae) is presented. Antenna flicking and attraction behaviors evoked by conspecifics of both sexes were recorded in arena bioassays, where attraction of females to males was observed. Air entrainment of both males and females was conducted in separate chambers. Gas chromatographic-mass spectrometric analysis of headspace volatiles revealed that two male-specific compounds, 4-methyl-3,5-heptanedione (major) and (4 S,5 S)-5-hydroxy-4-methyl-3-heptanone (minor), were emitted during the autumnal post-aestivatory flight period. The stereoisomers of the minor component were separated by enantioselective gas chromatography and their absolute configurations assigned by NMR (diastereomers) and the known preference of enantioselective transesterification reactions catalyzed by Candida antarctica lipase B. Electroantennogram and single sensillum recording studies indicate that 4-methyl-3,5-heptanedione as well as all individual stereoisomers of 5-hydroxy-4-methyl-3-heptanone are detected by the antennae of male and female S. discoideus. Further, single sensillum recordings suggest that both sexes of S. discoideus have specialized olfactory receptor neurons (ORNs) for detecting 4-methyl-3,5-heptanedione and different populations of stereoselective ORNs for detecting the stereoisomers of 5-hydroxy-4-methyl-3-heptanone. Some of these stereoselective ORNs appear to be sex-specific in S. discoideus.
A high pressure modulated molecular beam mass spectrometric sampling system
NASA Technical Reports Server (NTRS)
Stearns, C. A.; Kohl, F. J.; Fryburg, G. C.; Miller, R. A.
1977-01-01
The current state of understanding of free-jet high pressure sampling is critically reviewed and modifications of certain theoretical and empirical considerations are presented. A high pressure, free-jet expansion, modulated molecular beam, mass spectrometric sampling apparatus was constructed and this apparatus is described in detail. Experimental studies have demonstrated that the apparatus can be used to sample high temperature systems at pressures up to one atmosphere. Condensible high temperature gaseous species have been routinely sampled and the mass spectrometric detector has provided direct identification of sampled species. System sensitivity is better than one tenth of a part per million. Experimental results obtained with argon and nitrogen beams are presented and compared to theoretical predictions. These results and the respective comparison are taken to indicate acceptable performance of the sampling apparatus. Results are also given for two groups of experiments related to hot corrosion studies. The formation of gaseous sodium sulfate in doped methane-oxygen flames was characterized and the oxidative vaporization of metals was studied in an atmospheric pressure flowing gas system to which gaseous salt partial pressures were added.
Yu, Conrad M.; Koo, Jackson C.
2000-01-01
A system and method for preconcentrating, identifying, and quantifying chemical and biological substances is disclosed. An input valve directs a first volume of a sample gas to a surface acoustic wave (SAW) device. The SAW device preconcentrates and detects a mass of a substance within the sample gas. An output valve receives a second volume of the sample gas containing the preconcentrated substance from the SAW device and directs the second volume to a gas chromatograph (GC). The GC identifies the preconcentrated substance within the sample gas. A shunt valve exhausts a volume of the sample gas equal to the first volume minus the second volume away from the SAW device and the GC. The method of the present invention includes the steps of opening an input valve for passing a first volume of a sample gas to a SAW device; preconcentrating and detecting a mass of a substance within the sample gas using the SAW device; opening an output valve for passing a second volume of the sample gas containing the preconcentrated substance to a gas chromatograph (GC); and then identifying the preconcentrated substance within the sample gas using the GC.
Aalberg, L; DeRuiter, J; Noggle, F T; Sippola, E; Clark, C R
2000-08-01
The popular drug of abuse 3,4-methylenedioxymethamphetamine (MDMA) is one of a total of 10 regioisomeric 2,3- and 3,4-methylenedioxyphenethylamines of MW 193 that yields regioisomeric fragment ions with equivalent mass (m/z 58 and 135/136) in the electron-impact (EI) mass spectrum. Thus, these 10 methylenedioxyphenethylamines are uniquely isomeric; they have the same molecular weight and equivalent major fragments in their mass spectra. The specific identification of one of these compounds (i.e., Ecstasy or 3,4-MDMA) in a forensic drug sample depends upon the analyst's ability to eliminate the other regioisomers as possible interfering or coeluting substances. This study reports the synthesis, chemical properties, spectral characterization, and chromatographic analysis of these 10 unique regioisomers. The ten 2,3- and 3,4-regioisomers of MDMA are synthesized from commercially available precursor chemicals. In the EI mass spectra, the side-chain regioisomers show some variation in the relative intensity of the major ions, with the exception of only one or two minor ions that might be considered side-chain specific fragments. The position of substitution for the methylenedioxy ring is not easily determined by mass spectral techniques, and the ultimate identification of any one of these amines with the elimination of the other nine must depend heavily upon chromatographic methods. The chromatographic separation of these 10 uniquely regioisomeric amines are studied using reversed-phase liquid chromatographic methods with gradient elution and gas chromatographic techniques with temperature program optimization.
Zhang, Li; Shen, Hong; Xu, Jun; Xu, Jin-Di; Li, Zhen-Ling; Wu, Jie; Zou, Ye-Ting; Liu, Li-Fang; Li, Song-Lin
2018-04-25
In this study, a novel ultra-performance liquid chromatography coupled with quadrupole/time-of-flight mass spectrometry (UPLC-QTOF-MS/MS)-guidance strategy was proposed for preparation of sulfur-containing derivatives in sulfur-fumigated edible herbs. Being versatile in both chromatographic separation and mass spectrometric detection, UPLC-QTOF-MS/MS was inducted into each experimental step for multifaceted purposes including finding, tracking, purity determination and structural elucidation of targeted compounds as well as UPLC-HPLC chromatographic conditions transplantation, whereby the isolation and purification procedures were greatly facilitated. Using this strategy, a new sulfur-containing ginsenoside Rg 1 derivative (named compound I) was obtained from sulfur-fumigated ginseng. The chemical structure of compound I was elucidated to be (3β, 6α, 12β)-3, 12-dihydroxydammar-25-ene-6, 20-diylbis-β-d-glucopyranoside, 24-sulfonic acid by QTOF-MS/MS, 1 H-NMR and 13 C-NMR analysis, and its generation mechanisms by sulfur-fumigation were accordingly discussed. The research deliverable suggests that the UPLC-QTOF-MS/MS-guidance strategy is promising for targeted preparation of sulfur-containing derivatives from sulfur-fumigated edible herbs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Srivastava, Abhishek; Waterhouse, David; Ardrey, Alison; Ward, Stephen A
2012-11-01
A highly sensitive and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed to measure the levels of the antitubercular drug rifampicin (RIF) in human plasma and cerebrospinal fluid (CSF). The analyte and internal standard (IS) were isolated from plasma and CSF by a simple organic solvent based precipitation of proteins followed by centrifugation. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring (MRM) mode. The assay was linear in the concentration range 25-6400 ng/mL with intra- and inter-day precision of <7% and <8%, respectively. The validated method was applied to the study of RIF pharmacokinetics in human CSF and plasma over 25 h period after a 10 mg/kg oral dose. Copyright © 2012 Elsevier B.V. All rights reserved.
Ontañon, I; Sanz, J; Escudero, A; de Marcos, S; Ferreira, V; Galbán, J
2015-04-03
A homemade flow cell attached to a commercial Gas Chromatograph equipped with a Flame Ionization Detector (FID) has been designed for the continuous monitoring of volatile compounds released during heating edible oils. Analytical parameters such as mass of sample, temperature and flow rates have been optimized and the obtained results have been compared with the corresponding thermographs from standard TG systems. Results show that under optimum conditions, the profiles of volatiles released upon heating are comparable to the profiles of TG curves, suggesting that the FID based system could be an alternative to TGA. Additionally, volatiles have been retained in a Lichrolut EN(®) resin, eluted and analyzed by Gas Chromatography-Mass Spectrometry. In this case, forty five compounds have been identified (acids, alcohols, alkanes, aldehydes, ketones and furans) and compared with the FID signals, working both in air or nitrogen atmosphere. It has been concluded that the oxidative thermal degradation is prevented in the presence of a nitrogen atmosphere. Copyright © 2015 Elsevier B.V. All rights reserved.
Miyawaki, Takashi; Kawashima, Ayato; Honda, Katsuhisa
2008-01-01
A method involving supercritical fluid extraction (SFE) with a solid phase trap containing activated alumina was investigated for the rapid analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin like polychlorinated biphenyls (DL-PCBs) in soils and sediments. The samples were extracted by using supercritical carbon dioxide with water (2% versus CO(2) flow velocity) being used as an entrainer at a pressure of 30 MPa and a temperature of 130 degrees C for 50 min. The extracts were adsorbed on an activated alumina trap that was maintained at a temperature of 150 degrees C, and then, PCDD/DFs and DL-PCBs were eluted with 20 ml of hexane at 60 degrees C. After concentration, they were measured with a high-resolution gas chromatograph interfaced to a high-resolution mass spectrometric detector. The average concentrations of PCDD/DFs and DL-PCBs corresponded to the results obtained by the conventional method, and the reproducibility of this SFE method was below 21% of the relative standard deviations for all samples. The total time required for the analysis of the pretreatment of this method was only 2 h.
Who Set the Fire? Determination of Arson Accelerants by GC-MS in an Instrumental Methods Course
NASA Astrophysics Data System (ADS)
Sodeman, David A.; Lillard, Sheri J.
2001-09-01
Forensic scenarios have advantages over traditional experiments in the instrumental laboratory from the perspectives of both teaching and learning. First, students feel that they are calculating more than just a number from their experiments and that their results have meaning. Second, we are teaching techniques that are used in the real world and students can no longer complain, "This is not how it is done in the real world." This experiment is designed for upper-division chemistry and chemical engineering majors taking an instrumental methods course. The experimental approach simulates the steps an arson investigator would take to determine if arson was the cause of a fire. Charred (unknown) samples of wood and five standards of liquid accelerants are prepared in sealed containers and presented to the students for headspace gas chromatography (GC) with quadrupole mass spectrometric (MS) detection. Students interpret the standards and the charred samples using chromatographic retention times and MS data. From this information, they determine which accelerant was used to start the fire. They are also asked to discuss differences between the chromatograms of the charred sample and the corresponding liquid accelerant.
Mechanisms and pathways of aniline elimination from aquatic environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyons, C.D.; Katz, S.; Bartha, R.
1984-09-01
The fate of aniline, a representative of arylamine pollutants derived from the manufacture of dyes, coal liquefaction, and pesticide degradation, was comprehensively evaluated by use of unpolluted and polluted pond water as model environments. Evaporation plus autoxidation proved to be minor elimination mechanisms, removing ca. 1% of the added aniline per day. Instantaneous binding to humic components of a 0.1% sewage sludge inoculum removed 4%. Biodegradation of aniline in pond water was accelerated by the sewage sludge inoculum. A substantial portion of the degraded aniline carbon was mineralized to CO/sub 2/ within a 1-week period, and microbial biomass was formedmore » as a result of analine utilization. Biodegradation was clearly the most significant removal mechanism of polluting aniline from pond water. A gas chromatographic-mass spectrometric analysis of biodegradation intermediates revealed that the major pathway of aniline biodegradation in pond water involved oxidative deamination to catechol, which was further metabolized through cis,cis-muconic, beta-ketoadipic, levulinic, and succinic acid intermediates to CO/sub 2/. Minor biodegradation pathways involved reversible acylation to acetanilide and formanilide, whereas N-oxidation resulted in small amounts of oligomeric condensation products. 36 references, 4 figures, 3 tables.« less
Roux, Olivier; Martin, Jean-Michel; Ghomsi, Nathan Tene; Dejean, Alain
2009-08-01
Interspecific relationships among insects are often mediated by chemical cues, including non-volatile cuticular compounds. Most of these compounds are hydrocarbons that necessitate the use of solvents for their extraction, identification, and manipulation during behavioral assays. The toxicity of these solvents often precludes the removal and reapplication of hydrocarbons from and to live insects. As a consequence, dummies often are used in behavioral assays, but their passivity can bias the behavior of the responding insects. To overcome these limitations, we propose a method where cuticular compounds are extracted from live ants by placing them into glass vials half-filled with tepid water (ca. 34 degrees C) and vigorously shaking the vials to form an emulsion whose supernatant can be analyzed and/or reapplied to other ants. We demonstrate that cuticular compounds can be extracted from workers of the red fire ant, Solenopsis saevissima, and reapplied to the cuticle of workers from a sympatric species, Camponotus blandus (both Hymenoptera: Formicidae), while keeping the ants alive. Gas chromatographic-mass spectrometric analysis and behavioral assays were used to confirm the successful transfer of the behaviorally active compounds.
Struempler, R E; Nelson, G; Urry, F M
1997-01-01
A commercially available health food product of cold-pressed hemp seed oil ingested by one volunteer twice a day for 4 1/2 days (135 mL total). Urine specimens collected from the volunteer were subjected to standard workplace urine drug testing procedures, and the following concentrations of 11-nor-delta9- tetrahydrocannabinol carboxylic acid (9-THCA) were detected: 41 ng/mL 9-THCA at 45 h, 49 ng/mL at 69 h, and 55 ng/mL at 93 h. Ingestion was discontinued after 93 h, and the following concentrations were detected: 68 ng/mL at 108 h, 57 ng/mL at 117 h, 31 ng/mL at 126 h, and 20 ng/mL at 142 h. The first specimen that tested negative (50 ng/mL initial immunoassay test, 15 ng/mL confirmatory gas chromatographic-mass spectrometric test) was at 146 h, which was 53 h after the last hemp seed oil ingestion. Four subsequent specimens taken to 177 h were also negative. This study indicates that a workplace urine drug test positive for cannabinoids may arise from the consumption of commercially available cold-pressed hemp seed oil.
Odham, Göran; Tunlid, Anders; Westerdahl, Gunilla; Mårdén, Per
1986-01-01
Extraction of lipids from bacterial cells or sewage sludge samples followed by simple and rapid extraction procedures and room temperature esterification with pentafluorobenzylbromide allowed combined determinations of poly-β-hydroxyalkanoate constituents and fatty acids. Capillary gas chromatography and flame ionization or mass spectrometric detection was used. Flame ionization permitted determination with a coefficient of variation ranging from 10 to 27% at the picomolar level, whereas quantitative chemical ionization mass spectrometry afforded sensitivities for poly-β-hydroxyalkanoate constituuents in the attomolar range. The latter technique suggests the possibility of measuring such components in bacterial assemblies with as few as 102 cells. With the described technique using flame ionization detection, it was possible to study the rapid formation of poly-β-hydroxyalkanoate during feeding of a starved marine bacterium isolate with a complex medium or glucose and correlate the findings to changes in cell volumes. Mass spectrometric detection of short β-hydroxy acids in activated sewage sludge revealed the presence of 3-hydroxybutyric, 3-hydroxyhexanoic, and 3-hydroxyoctanoic acids in the relative proportions of 56, 5 and 39%, respectively. No odd-chain β-hydroxy acids were found. PMID:16347181
Mass spectrometric characterization of naphthenic acids in environmental samples: a review.
Headley, John V; Peru, Kerry M; Barrow, Mark P
2009-01-01
There is a growing need to develop mass spectrometric methods for the characterization of oil sands naphthenic acids (structural formulae described by C(n)H(2n+z)O(2) where n is the number of carbon atoms and "z" is referred to as the "hydrogen deficiency" and is equal to zero, or is a negative, even integer) present in environmental samples. This interest stems from the need to better understand their contribution to the total acid number of oil sands acids; along with assessing their toxicity in aquatic environments. Negative-ion electrospray ionization has emerged as the analytical technique of choice. For infusion samples, matrix effects are particularly evident for quantification in the presence of salts and co-elutants. However, such effects can be minimized for methods that employ chromatographic separation prior to mass spectrometry (MS) detection. There have been several advances for accurate identification of classes of naphthenic acid components that employ a range of MS hyphenated techniques. General trends measured for degradation of the NAs in the environment appear to be similar to those obtained with either low- or high-resolution MS. Future MS research will likely focus on (i) development of more reliable quantitative methods that use chromatography and internal standards, (ii) the utility of representative model naphthenic acids as surrogates for the complex NA mixtures, and (iii) development of congener-specific analysis of the principal toxic components.
Device for collecting and analyzing matrix-isolated samples
Reedy, Gerald T.
1979-01-01
A gas-sample collection device is disclosed for matrix isolation of individual gas bands from a gas chromatographic separation and for presenting these distinct samples for spectrometric examination. The device includes a vacuum chamber containing a rotatably supported, specular carrousel having a number of external, reflecting surfaces around its axis of rotation for holding samples. A gas inlet is provided for depositing sample and matrix material on the individual reflecting surfaces maintained at a sufficiently low temperature to cause solidification. Two optical windows or lenses are installed in the vacuum chamber walls for transmitting a beam of electromagnetic radiation, for instance infrared light, through a selected sample. Positioned within the chamber are two concave mirrors, the first aligned to receive the light beam from one of the lenses and focus it to the sample on one of the reflecting surfaces of the carrousel. The second mirror is aligned to receive reflected light from that carrousel surface and to focus it outwardly through the second lens. The light beam transmitted from the sample is received by a spectrometer for determining absorption spectra.
On the ability of the Viking gas chromatograph-mass spectrometer to detect organic matter.
Biemann, Klaus
2007-06-19
A recent paper by Navarro-Gonzalez et al. [Navarro-Gonzalez R, Navarro KF, de la Rosa J, Iniguez E, Molina P, Miranda LD, Morales P, Cienfuegos E, Coll P, Raulin F, et al. (2006) Proc Natl Acad Sci USA 103:16089-16094] claims to show that the Viking GCMS (gas chromatograph-mass spectrometer) experiment, which carried out a search for organic matter at the surface of Mars in 1976, "may have been blind to low levels of organics." To rebut this assertion, the Viking experiment, test data, and results on Mars are reviewed, and the fallacies in the design, execution, and interpretation of the new experiments presented by Navarro-Gonzalez et al. are critically examined.
NASA Astrophysics Data System (ADS)
Raulin, F.; Sternberg, R.; Coscia, D.; Vidal-Madjar, C.; Millot, M.-C.; Sébille, B.; Israel, G.
1999-01-01
Several planetary exploration missions have already used chromatographic techniques to search for organic compounds, including complex organics, in extraterrestrial environments. So far, only gas chromatography (GC) has been used. In two cases (Viking and Cassini-Huygens), a Py-GC-MS instrument, coupling GC with a pyrolyzer and a mass spectrometer, has been flown. Powerful miniaturized Py-GC-MS instrumentation, with high resolution multi-GC columns and time-of-flight or Ion Trap mass spectrometers are under development, in the frame of the preparation of the Rosetta mission. There is now a strong need for new chromatographic instrumentation in space, in particular to perform detailed molecular analyses of complex non-volatile organics, including macromolecular compounds. Liquid Chromatography (LC), in particular High Performance Liquid Chromatography (HPLC) Supercritical Fluid Chromatography (SFC) or Chemical-Derivatization Gas Chromatography (CDGC) could provide a very efficient mean of analyzing a wide variety of exobiologically important compounds. LC or CDGC have never been used in space yet, but feasibility studies on their application in planetary mission are needed.
Huygens Gas Chromatograph Mass Spectrometer Results from Titan
NASA Technical Reports Server (NTRS)
Niemann, Hasso
2008-01-01
The Huygens Probe executed a successful entry, descent and impact on the Saturnian moon of Titan on January 14, 2005. Gas Chromatograph Mass Spectrometer (GCMS) instrument conducted isotopic and compositional measurements throughout the two and one half hour descent from 146 km altitude, and on the surface for 69 minutes until loss of signal from the orbiting Cassini spacecraft. The GCMS incorporated a quadrupole mass filter with a secondary electron multiplier detection system. The gas sampling system provided continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact. Data products from the GCMS included altitude profiles of the major atmospheric constituents dinitrogen (N2) and methane (CH4), isotope ratios of N-14/N-15, C-12/C-13, and D/H, mole fractions of radiogenic argon (Ar-40)and primordial argon Ar-36), and upper limits on the mole fractions of neon, krypton and xenon, which were found to be below the detection limit of the instrument or absent. Surface measurements confirmed the presence of ethane (C2H6) and cyanogen (C2N2). Later data products include the instrument response to surface outgassing of C2N2, C2H6, acetylene (C2H2),and carbon dioxide (CO2). More recent results include the detection of benzene (C6H6) and height profiles of molecular hydrogen (H2). Numerous other trace species evaporating from the surface were also identified using the GCMS data.
Deethyl atrazine (DEA), along with other triazine degradation products, has been added to the US Environmental Protection Agency's Drinking Water Contaminant Candidate List (CCL). In its gas chromatographic (GC) analysis, deethyl atrazine, a degradation product of atrazine, can ...
Jalali-Heravi, Mehdi; Moazeni-Pourasil, Roudabeh Sadat; Sereshti, Hassan
2015-03-01
In analysis of complex natural matrices by gas chromatography-mass spectrometry (GC-MS), many disturbing factors such as baseline drift, spectral background, homoscedastic and heteroscedastic noise, peak shape deformation (non-Gaussian peaks), low S/N ratio and co-elution (overlapped and/or embedded peaks) lead the researchers to handle them to serve time, money and experimental efforts. This study aimed to improve the GC-MS analysis of complex natural matrices utilizing multivariate curve resolution (MCR) methods. In addition, to assess the peak purity of the two-dimensional data, a method called variable size moving window-evolving factor analysis (VSMW-EFA) is introduced and examined. The proposed methodology was applied to the GC-MS analysis of Iranian Lavender essential oil, which resulted in extending the number of identified constituents from 56 to 143 components. It was found that the most abundant constituents of the Iranian Lavender essential oil are α-pinene (16.51%), camphor (10.20%), 1,8-cineole (9.50%), bornyl acetate (8.11%) and camphene (6.50%). This indicates that the Iranian type Lavender contains a relatively high percentage of α-pinene. Comparison of different types of Lavender essential oils showed the composition similarity between Iranian and Italian (Sardinia Island) Lavenders. Published by Elsevier B.V.
Treble, Ronald G; Johnson, Keith E; Xiao, Li; Thompson, Thomas S
2002-07-01
An existing gas chromatograph/mass spectrometer (GC/MS) can be used to analyze gas and liquid fractions from the same system within a few minutes. The technique was applied to (a) separate and identify the gaseous components of the products of cracking an alkane, (b) measure trace levels of acetone in ethyl acetate, (c) determine the relative partial pressures over a binary mixture, and (d) identify nine unknown compounds for the purpose of disposal.
Waktola, Habtewold D; Mjøs, Svein A
2018-04-01
The chromatographic efficiency that could be achieved in temperature-programmed gas chromatography was compared for four capillary columns that are typically applied for analysis of fatty acid methyl esters (FAME). Three different carrier gases, hydrogen, helium and nitrogen, were applied. For each experiment, the carrier gas velocities and the temperature rates were varied with a full 9 × 3 design, with nine levels on the carrier gas velocity and temperature rates of 1, 2 or 3°C/min. Response surface methodology was used to create models of chromatographic efficiency as a function of temperature rate and carrier gas velocity. The chromatographic efficiency was defined as the inverse of peak widths measured in retention index units. The final results were standardized so that the efficiencies that could be achieved within a certain time frame, defined by the retention time of the last compound in the chromatogram, could be compared. The results show that there were clear differences in the efficiencies that could be achieved with the different columns and that the efficiency decreased with increasing polarity of the stationary phase. The differences can be explained by higher resistance to mass transfer in the stationary phase in the most polar columns. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Kenzhegaliev, Akimgali; Zhumagaliev, Sagat; Kenzhegalieva, Dina; Orazbayev, Batyr
2018-03-01
Prior to the start of experimental oil production in the Kashagan field (northern part of the Caspian Sea), n-alkanes and carboxylic acids contained in samples obtained from bottom sediments in the area of artificial island "D" were investigated by gas chromatography-mass spectrometry. Concentrations of 10 n-alkanes (composed of C10-C13, C15-C20) and 11 carboxylic acids (composed of C6-C12, C14-C16) were identified and measured. Concentrations of individual alkanes and carboxylic acids in bottom sediments of the various samples varied between 0.001 ÷ 0.88 μg/g and 0.001 ÷ 1.94 μg/g, respectively. Mass spectra, in particular the M+ molecular ion peak and the most intense peaks of fragment ions, are given. The present study illustrates the stability of molecular ions to electronic ionisation and the main fragment ions to the total ion current and shows that the initial fragmentation of alkanes implies radical cleavage of C2H5 rather than CH3. All aliphatic monocarboxylic acids studied were characterised by McLafferty rearrangement leading to the formation of F4 cation-radical with m/z 60 and F3 cation-radical with m/z 88 in the case of ethylhexanoic acid. The formation of oxonium ions presents another important aspect of acid fragmentation. Using mass numbers of oxonium ions and rearrangement ions allows determination of the substitution character in α- and β- C atoms. The essence of our approach is to estimate the infiltration of hydrocarbon fluids from the enclosing formation into sea water, comprising an analysis of derivatives of organic compounds in bottom sediments. Thus, concentrations of derived organic molecules can serve as a basis for estimates of the depth at which hydrocarbon fluids leak, i.e., to serve as an auxiliary technique in the search for hydrocarbon deposits and to repair well leaks.
NASA Technical Reports Server (NTRS)
Nuss, H. E.
1975-01-01
The measuring and evaluation procedure for the determination of leak rates of satellite subsystems with a quadrupole mass spectrometer, and the results of the residual gas analysis are described. The method selected for leak rate determination was placing the system into a vacuum chamber and furnishing the chamber with a mass spectrometer and calibrated leaks. The residual gas of a thermal vacuum test facility, in which the thermal balance test radiation input was simulated by a heated canister, was analyzed with the mass spectrometer in the atomic mass unit range up to 300 amu. In addition to the measurements during the space environment tests, mass spectrometric studies were performed with samples of spacecraft materials. The studies were carried out during tests for the projects HELIOS, AEROS B and SYMPHONIE.
Dual liquid and gas chromatograph system
Gay, D.D.
A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.
Dual liquid and gas chromatograph system
Gay, Don D.
1985-01-01
A chromatographic system that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a non-transparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extremely low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.
Cescutti, Paola; Foschiatti, Michela; Furlanis, Linda; Lagatolla, Cristina; Rizzo, Roberto
2010-07-02
The repeating unit of cepacian, the exopolysaccharide produced by the majority of the microorganisms belonging to the Burkholderia cepacia complex, was isolated from inner bacterial membranes and investigated by mass spectrometry, with and without prior derivatisation. Interpretation of the mass spectra led to the determination of the biological repeating unit primary structure, thus disclosing the nature of the oligosaccharide produced in vivo. Moreover, mass spectra recorded on the native sample revealed that acetyl substitution was very variable, producing a mixture of repeating units containing zero to four acyl groups. At the same time, finding acetylated oligosaccharides showed that binding of these substituents occurred in the cellular periplasmic space, before the polymerisation process took place. In the chromatographic peak containing the repeating unit, oligosaccharides shorter than the repeating unit co-eluted. Mass spectrometric analysis showed that they were biosynthetic intermediates of the repeating unit and further investigation revealed the biosynthetic sequence of cepacian building block. Copyright 2010 Elsevier Ltd. All rights reserved.
Analysis of Low-Pressure Gas-Phase Pyrolytic Reactions by Mass Spectrometric Techniques,
1989-01-01
temperatures and pressures known only as a polymeric substance, is similarly obtained in high purity by heating the polymer to its melting point (105-110’ C...filaments for Curie- point pyrolysis’ J.Anal.Appl.Pyrolysis. 5 (1983) 1-7 (with Helge Egsgaard) 4) ’Heterogeneous catalysis in gas phase reactions studied...by Curie- point pyrolysis. Gas phase pyrolysis of methyl dithio- acetat’ J.Anal.Appl.Pyrolysis. 5 (1983) 257-259 (with Helge Egsgaard) 5) ’Continuous
Ciofi, L; Ancillotti, C; Chiuminatto, U; Fibbi, D; Checchini, L; Orlandini, S; Del Bubba, M
2014-10-03
Four different pellicular stationary phases (i.e. octadecylsilane, octasilane, Phenyl-Hexyl and pentafluorophenyl) were investigated for the chromatographic resolution of alkylphenols (APs), alkylphenols polyethoxylates (APnEOs) and alkylphenoxy carboxylates (APECs) using mixtures of water and organic solvents (i.e. methanol, acetonitrile and tetrahydrofuran) as eluents, in order to obtain their determination by a single LC-MS/MS run. In fact, alkylphenols and alkylphenoxy carboxylates must be analysed in negative ion mode, whereas alkylphenols polyethoxylates undergo ionisation only in positive ion mode, and therefore, two distinct LC-MS/MS analysis are commonly adopted. The best resolution among the aforementioned target analytes was achieved on the pentafluorophenyl column, eluting with an acidified water-acetonitrile-tetrahydrofuran mixture and using the post column addition of an ammonia solution in methanol for the detection of positively ionisable compounds. Under these optimized chromatographic conditions the investigated compounds were determined via a single chromatographic run, with only one polarity switch, in 15min, achieving the following instrumental detection limits: 600pg for AP1EOs, 0.8-14pg for AP2EOs, 10.4-150pg for APs and 4.4-4.8pg for APECs. The chromatographic method was coupled with solid-phase extraction and clean-up procedures and successfully applied to the analysis of wastewater and surface water samples, highlighting mean concentration ranging from 6ng/L for 4-t-OP1EC to 1434ng/L for 4-NP1121EC, depending on the sample analysed. Copyright © 2014 Elsevier B.V. All rights reserved.
A system that couples a gas chromatograph (GC) via a split to a quadrapole mass spectrometer (MS) and, through a combustion interface, to an isotope ratio mass spectrometer (IRMS) allows the simultaneous detection of electron impact mass spectra and stable carbon isotope ratio an...
USDA-ARS?s Scientific Manuscript database
Lippia alba extracts from Mexico were obtained by hydrodistillation (HD) and supercritical fluid (SFE) extraction methods. The extracts were analyzed by gas chromatography using flame ionization and mass spectrometric detections. Antioxidant activity was tested by two methods (DPPH and ABTS) and tot...
Adulticidal activity of essential oil of Lantana camara leaves against mosquitoes.
Dua, V K; Pandey, A C; Dash, A P
2010-03-01
Development of insect resistance to synthetic pesticides, high operational cost and environmental pollution have created the need for developing alternative approaches to control vector-borne diseases. In the present study we have investigated the insecticidal activity of essential oil isolated from the leaves of Lantana camara against mosquito vectors. Essential oil was isolated from the leaves of L. camara using hydro-distillation method. Bioassay test was carried out by WHO method for determination of adulticidal activity against mosquitoes. Different compounds were identified by gas chromatography-mass spectrometry analysis. LD(50) values of the oil were 0.06, 0.05, 0.05, 0.05 and 0.06 mg/cm(2) while LD(90) values were 0.10, 0.10, 0.09, 0.09 and 0.10 mg/cm(2) against Ae. aegypti, Cx. quinquefasciatus, An. culicifacies, An. fluvialitis and An. stephensi respectively. KDT(50) of the oil were 20, 18, 15, 12, and 14 min and KDT(90) values were 35, 28 25, 18, 23 min against Ae. aegypti, Cx. quinquefasciatus, An. culicifacies, An. fluviatilis and An. stephensi, respectively on 0.208 mg/cm(2) impregnated paper. Studies on persistence of essential oil of L. camara on impregnated paper revealed that it has more adulticidal activity for longer period at low storage temperature. Gas chromatographic-mass spectrometric analysis of essential oil showed 45 peaks. Caryophyllene (16.37%), eucalyptol (10.75%), alpha-humelene (8.22%) and germacrene (7.41%) were present in major amounts and contributed 42.75 per cent of the total constituents. Essential oil from the leaves of L. camara possesses adulticidal activity against different mosquito species that could be utilized for development of oil-based insecticide as supplementary to synthetic insecticides.
NASA Technical Reports Server (NTRS)
Lavoie, R. C.
1974-01-01
Fundamantal concepts are developed which are required to optimize a gas chromatograph-mass spectrometer chemical analysis system suitable for use on an unmanned roving vehicle for Mars exploration. Prior efforts have developed simulation models for the chromatograph which were compared with data obtained from a test facility. Representation of binary systems by superposition was shown to be a first-order approximation and in certain cases large discrepencies were noted. This subtask has as its objective generation of additional binary data and analysis of the observed nonlinear effects.
Mass spectrometric measurements of driver gas arrival in the T4 free-piston shock-tunnel
NASA Astrophysics Data System (ADS)
Boyce, R. R.; Takahashi, M.; Stalker, R. J.
2005-12-01
Available test time is an important issue for ground-based flow research, particularly for impulse facilities such as shock tunnels, where test times of the order of several ms are typical. The early contamination of the test flow by the driver gas in such tunnels restricts the test time. This paper reports measurements of the driver gas arrival time in the test section of the T4 free-piston shock-tunnel over the total enthalpy range 3 17 MJ/kg, using a time-of-flight mass spectrometer. The results confirm measurements made by previous investigators using a choked duct driver gas detector at these conditions, and extend the range of previous mass spectrometer measurements to that of 3 20 MJ/kg. Comparisons of the contamination behaviour of various piston-driven reflected shock tunnels are also made.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-15
... using capillary gas liquid chromatography (GLC) with flame ionization detector (FID). Contact: Andrew...) purification. Detection and quantitation are conducted by gas chromatograph equipped with nitrogen phosphorus... pressure liquid chromatography/triple stage quadrupole mass spectrometry (LC/MS/MS) using the stable...
Fluorotelomer alcohols (FTOHs) have been widely studied as precursors to perfluorocarboxylates, e.g. 8:2 FTOH degrades to perfluorooctanoic acid (PFOA). This presentation describes an analytical method for the extraction and analysis of 6:2, 8:2, and 10:2 FTOHs. Gas chromatograph...
Shang, Tanya Q; Saati, Andrew; Toler, Kelly N; Mo, Jianming; Li, Heyi; Matlosz, Tonya; Lin, Xi; Schenk, Jennifer; Ng, Chee-Keng; Duffy, Toni; Porter, Thomas J; Rouse, Jason C
2014-07-01
A highly robust hydrophilic interaction liquid chromatography (HILIC) method that involves both fluorescence and mass spectrometric detection was developed for profiling and characterizing enzymatically released and 2-aminobenzamide (2-AB)-derivatized mAb N-glycans. Online HILIC/mass spectrometry (MS) with a quadrupole time-of-flight mass spectrometer provides accurate mass identifications of the separated, 2-AB-labeled N-glycans. The method features a high-resolution, low-shedding HILIC column with acetonitrile and water-based mobile phases containing trifluoroacetic acid (TFA) as a modifier. This column and solvent system ensures the combination of robust chromatographic performance and full compatibility and sensitivity with online MS in addition to the baseline separation of all typical mAb N-glycans. The use of TFA provided distinct advantages over conventional ammonium formate as a mobile phase additive, such as, optimal elution order for sialylated N-glycans, reproducible chromatographic profiles, and matching total ion current chromatograms, as well as minimal signal splitting, analyte adduction, and fragmentation during HILIC/MS, maximizing sensitivity for trace-level species. The robustness and selectivity of HILIC for N-glycan analyses allowed for method qualification. The method is suitable for bioprocess development activities, heightened characterization, and clinical drug substance release. Application of this HILIC/MS method to the detailed characterization of a marketed therapeutic mAb, Rituxan(®), is described. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Rosenberg, Erwin
2003-06-06
The use of mass spectrometry based on atmospheric pressure ionisation techniques (atmospheric pressure chemical ionisation, APCI, and electrospray ionisation, ESI) for speciation analysis is reviewed with emphasis on the literature published in and after 1999. This report accounts for the increasing interest that atmospheric pressure ionisation techniques, and in particular ESI, have found in the past years for qualitative and quantitative speciation analysis. In contrast to element-selective detectors, organic mass spectrometric techniques provide information on the intact metal species which can be used for the identification of unknown species (particularly with MS-MS detection) or the confirmation of the actual presence of species in a given sample. Due to the complexity of real samples, it is inevitable in all but the simplest cases to couple atmospheric pressure MS detection to a separation technique. Separation in the liquid phase (capillary electrophoresis or liquid chromatography in reversed phase, ion chromatographic or size-exclusion mode) is particularly suitable since the available techniques cover a very wide range of analyte polarities and molecular mass. Moreover, derivatisation can normally be avoided in liquid-phase separation. Particularly in complex environmental or biological samples, separation in one dimension is not sufficient for obtaining adequate resolution for all relevant species. In this case, multi-dimensional separation, based on orthogonal separation techniques, has proven successful. ESI-MS is also often used in parallel with inductively coupled plasma MS detection. This review is structured in two parts. In the first, the fundamentals of atmospheric pressure ionisation techniques are briefly reviewed. The second part of the review discusses recent applications including redox species, use of ESI-MS for structural elucidation of metal complexes, characterisation and quantification of small organometallic species with relevance to environment, health and food. Particular attention is given to the characterisation of biomolecules and metalloproteins (metallothioneins and phytochelatins) and to the investigation of the interaction of metals and biomolecules. Particularly in the latter field, ESI-MS is the ideal technique due to the softness of the ionisation process which allows to assume that the detected gas-phase ions are a true representation of the ions or ion-biomolecule complexes prevalent in solution. It is particularly this field, important to biochemistry, physiology and medical chemistry, where we can expect significant developments also in the future.
Zachariadis, G A; Rosenberg, E
2009-04-15
A method for the determination of organotin compounds in urine samples based on liquid-liquid extraction (LLE) in hexane and gas chromatographic separation was developed and optimized. Seven organotin species, namely monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), tetrabutyltin (TeBT), monophenyltin (MPhT), diphenyltin (DPhT) and triphenyltin (TPhT), were in situ derivatized by sodium tetraethylborate (NaBEt(4)) to form ethylated less polar derivatives directly in the urine matrix. The critical parameters which have a significant effect on the yield of the successive liquid-liquid extraction procedure were examined, by using standard solutions of tetrabutyltin in hexane. The method was optimized for use in direct analysis of undiluted human urine samples and ways to overcome practical problems such as foam formation during extraction, due to various constituents of urine are discussed. After thorough optimization of the extraction procedure, all examined species could be determined after 3 min of simultaneous derivatization and extraction at room temperature and 5 min phase separation by centrifugation. Gas chromatography with a microwave-induced plasma atomic emission detector (MIP-AED) as element specific detector was employed for quantitative measurements, while a quadrupole mass spectrometric detector (MS) was used as molecular specific detector. The detection limits were between 0.42 and 0.67 microg L(-1) (as Sn) for the quantitative LLE-GC-MIP-AED method and the precision between 4.2% and 11.7%, respectively.
Spectrometric determination of clinically relevant fatty acids in the blood serum
NASA Astrophysics Data System (ADS)
Kalinin, A. V.; Krasheninnikov, V. N.; Sviridov, A. P.; Titov, V. N.
2017-01-01
The content of fatty acid (FA) triglycerides in food and biological media is predicting traditionally using gas and liquid chromatographic methods. Named techniques aren't available for clinical labs due to their complexity. So, our objective was to develop the method and apparatus for rapid assay of a few clinically important FA as the saturated palmitic, mono unsaturated oleic and others in serum using near infrared spectrometer. As a result, the applicability of the FT spectrometer in the wavelength range of 0.9 -1.8 μ to analyze these FA in serum without sample preparation was confirmed. Besides, measurement specifications were determined and a correlations of the absorption spectra and contents of total triglycerides and cholesterol, palmitic, oleic, linoleic and arachidonic FA in serum were established
Siddiqui, Masoom Raza; Wabaidur, Saikh Mohammad; Khan, Moonis Ali; ALOthman, Zeid A; Rafiquee, M Z A; Alqadami, Ayoub Abdullah
2018-01-01
Quantitative assessment of nitrite (NO 2 - ) anion was performed using a newly developed high throughput ultra performance liquid chromatography-mass spectrometric (UPLC-MS) method. The nitrite determination with the proposed method using micellar mobile phase was unknown. Selected ion reaction mode using negative electrospray ionization was adopted for the identification and quantitative analysis of nitrite. The chromatographic separation was performed using BEH C-18 column and a micellar mobile phase consisted of sodium dodecyl sulphate and acetonitrile in ratio 30:70 was used. The elution of nitrite anion was accomplished in less than 1 min. Under the optimal analysis conditions, the linearity of the developed method was checked in the concentration range of 0.5-20 mg kg -1 NO 2 - with an excellent correlation coefficient of 0.996. The precisions of the method with relative standard deviation <2% was observed when standard at concentration of 1 mg kg -1 was used. The limit of detection and limit of quantitation of the developed mass spectrometric method was found to be 0.114 and 0.346 mg kg -1 , respectively. The developed UPLC/MS method was applied to quantify this anion in processed meats and poultries from various super market of Saudi Arabia (Riyadh region). The recoveries of the nitrite in the various samples were found in the range of 100.03-103.5%.
Peng, Ying; Chang, Qingqing; Yang, Na; Gu, Shiyin; Zhou, Yi; Yin, Lifang; Aa, Jiye; Wang, Guangji; Sun, Jianguo
2018-04-01
A simple, sensitive and specific hydrophilic interaction liquid chromatography coupled to electrospray ionization mass spectrometric (HILIC-MS) method was developed and validated to determine the plasma concentrations of metformin, saxagliptin and 5-hydroxy saxagliptin simultaneously in clinical studies. Plasma samples were first acidified and then protein precipitated with acetonitrile. Chromatographic separation was achieved on a HILIC Chrom Matrix HP amide column (5 μm, 3.0 × 100 mm I.D.). The mobile phase consisted of acetonitrile and 5 mM ammonium formate buffer containing 0.1% formic acid. Multiple reaction monitoring transitions were performed on triple quadrupole mass spectrometric detection in positive-ion mode with an electrospray ionization source. The calibration curves showed good linearity (r ≥ 0.999) over the established concentration range of 1.0-1000 ng/mL for metformin and 0.1-100 ng/mL for saxagliptin and its active metabolite 5-hydroxy saxagliptin. The extraction recovery for all of the analytes was >92% and the matrix effect ranged from 91.0 to 110.0%. After validation, the method was successfully applied to a bioequivalence study with a single-pill combination (SPC) consisting of 5 mg saxagliptin and 500 mg metformin in 10 healthy Chinese subjects. Copyright © 2018. Published by Elsevier B.V.
Rehman, Shaheed Ur; Kim, In Sook; Choi, Min Sun; Luo, Zengwei; Yao, Guangming; Xue, Yongbo; Zhang, Yonghui; Yoo, Hye Hyun
2016-02-20
Kinsenoside is a major bioactive constituent isolated from Anoectochilus formosanus and is investigated as an antihyperlipidemic candidate. In this study, a rapid, sensitive, and reliable bioanalytical method was developed for the determination of kinsenoside in rat plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). The plasma sample was pretreated with 1% acetic acid, followed by protein precipitation with acetonitrile:methanol (70:30). Chromatographic separation was performed on a HILIC silica column (2.1mm×100mm, 3μm). The mobile phases consisted of 0.1% acetic acid in distilled water (solvent A) and 0.1% acetic acid in acetonitrile (solvent B). A gradient program was used at a flow rate of 0.2mL/min. For mass spectrometric detection, the multiple reaction monitoring mode was used; the MRM transitions were m/z 265.2→m/z 102.9 for kinsenoside and m/z 163.3→m/z 132.1 for the internal standard (IS) nicotine in the positive ionization mode. A calibration curve was constructed in the range of 2-500ng/mL. The intra- and interday precision and accuracy were within 5%. The HILIC-MS/MS method was specific, accurate, and reproducible and was successfully applied in a pharmacokinetic study of kinsenoside in rats. Copyright © 2015 Elsevier B.V. All rights reserved.
Alshogran, Osama Y; Ocque, Andrew J; Leblond, François A; Pichette, Vincent; Nolin, Thomas D
2016-04-01
A simple and rapid liquid chromatographic-tandem mass spectrometric method has been developed and validated for the enantiospecific determination of R- and S-warfarin in human urine. Warfarin enantiomers were extracted from urine using methyl tert-butyl ether. Chromatographic separation of warfarin enantiomers and the internal standard d5-warfarin was achieved using a Astec Chirobiotic V column with gradient mobile phase at a flow rate of 400 µL/min over 10 min. Detection was performed on a TSQ Quantum Ultra triple quadrupole mass spectrometer equipped with a heated electrospray ionization source. Analytes were detected in negative ionization mode using selected reaction monitoring. Calibration curves were linear with a correlation coefficient of ≥0.996 for both enantiomers over a concentration range of 5-500 ng/mL. The intra- and interday accuracy and precision for both analytes were within ±9.0%. Excellent extraction efficiency and negligible matrix effects were observed. The applicability of the method was demonstrated by successful measurement of warfarin enantiomers in urine of patients with kidney disease. The method is simple, accurate and reproducible and is currently being used to support warfarin pharmacokinetic studies. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lee, Myung-Jae; Lee, Heon-Woo; Kang, Jong-Min; Seo, Ji-Hyung; Tak, Seong-Kun; Shim, Wangseob; Yim, Sung-Vin; Hong, Seung Jae; Lee, Kyung-Tae
2010-10-01
We describe a simple, rapid and sensitive high-performance liquid chromatography-electrospray ionization tandem mass spectrometric method that was developed for the simultaneous determination of carebastine and pseudoephedrine in human plasma using cisapride as an internal standard. Acquisition was performed in multiple-reaction monitoring mode by monitoring the transitions: m/z 500.43 > 167.09 for carebastine and m/z 166.04 > 147.88 for pseudoephedrine. The devised method involves a simple single-step liquid-liquid extraction with ethyl acetate. Chromatographic separation was performed on a C(18) reversed-phase chromatographic column at 0.2 mL/min by isocratic elution with 10 mM ammonium formate buffer-acetonitrile (30:70, v/v; adjusted to pH 3.3 with formic acid). The devised method was validated over 0.5-100 ng/mL of carebastine and 5-1000 ng/mL of pseudoephedrine with acceptable accuracy and precision, and was successfully applied to a bioequivalence study involving a single oral dose (10 mg of ebastine plus 120 mg of pseudoephedrine complex) to healthy Korean volunteers. Copyright © 2010 John Wiley & Sons, Ltd.
Glycan reductive isotope labeling for quantitative glycomics.
Xia, Baoyun; Feasley, Christa L; Sachdev, Goverdhan P; Smith, David F; Cummings, Richard D
2009-04-15
Many diseases and disorders are characterized by quantitative and/or qualitative changes in complex carbohydrates. Mass spectrometry methods show promise in monitoring and detecting these important biological changes. Here we report a new glycomics method, termed glycan reductive isotope labeling (GRIL), where free glycans are derivatized by reductive amination with the differentially coded stable isotope tags [(12)C(6)]aniline and [(13)C(6)]aniline. These dual-labeled aniline-tagged glycans can be recovered by reverse-phase chromatography and can be quantified based on ultraviolet (UV) absorbance and relative ion abundances. Unlike previously reported isotopically coded reagents for glycans, GRIL does not contain deuterium, which can be chromatographically resolved. Our method shows no chromatographic resolution of differentially labeled glycans. Mixtures of differentially tagged glycans can be directly compared and quantified using mass spectrometric techniques. We demonstrate the use of GRIL to determine relative differences in glycan amount and composition. We analyze free glycans and glycans enzymatically or chemically released from a variety of standard glycoproteins, as well as human and mouse serum glycoproteins, using this method. This technique allows linear relative quantitation of glycans over a 10-fold concentration range and can accurately quantify sub-picomole levels of released glycans, providing a needed advancement in the field of glycomics.
GLYCAN REDUCTIVE ISOTOPE LABELING (GRIL) FOR QUANTITATIVE GLYCOMICS
Xia, Baoyun; Feasley, Christa L.; Sachdev, Goverdhan P.; Smith, David F.; Cummings, Richard D.
2009-01-01
Many diseases and disorders are characterized by quantitative and/or qualitative changes in complex carbohydrates. Mass spectrometry methods show promise in monitoring and detecting these important biological changes. Here we report a new glycomics method, termed Glycan Reductive Isotope Labeling (GRIL), where free glycans are derivatized by reductive amination with the differentially coded stable isotope tags [12C6]-aniline and [13C6]-aniline. These dual-labeled aniline-tagged glycans can be recovered by reversed-phase chromatography and quantified based on UV-absorbance and relative ion abundances. Unlike previously reported isotopically coded reagents for glycans, GRIL does not contain deuterium, which can be chromatographically resolved. Our method shows no chromatographic resolution of differentially labeled glycans. Mixtures of differentially tagged glycans can be directly compared and quantified using mass spectrometric techniques. We demonstrate the use of GRIL to determine relative differences in glycan amount and composition. We analyze free glycans and glycans enzymatically or chemically released from a variety of standard glycoproteins, as well as human and mouse serum glycoproteins using this method. This technique allows for linear, relative quantitation of glycans over a 10-fold concentration range and can accurately quantify sub-picomole levels of released glycans, providing a needed advancement in the field of Glycomics. PMID:19454239
Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A
2014-09-01
Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. Copyright © 2014 Elsevier B.V. All rights reserved.
Parsons, Teresa L.; Emory, Joshua F.; Seserko, Lauren A.; Aung, Wutyi S.; Marzinke, Mark A.
2014-01-01
Background Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Methods Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically-labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50 × 2.1 mm, 1.7 µm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Results Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05 to 25 ng/tear strip, and 0.025 to 25 ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25 to 125 ng/swab for dapivirine and 0.125 to 125 ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000 ng/tear strip and 11,250 ng/swab. Standard curves were generated via weighted (1/x2) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. Conclusions A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. PMID:25005891
Mass Spectrometric Imaging Using Laser Ablation and Solvent Capture by Aspiration (LASCA)
NASA Astrophysics Data System (ADS)
Brauer, Jonathan I.; Beech, Iwona B.; Sunner, Jan
2015-09-01
A novel interface for ambient, laser ablation-based mass spectrometric imaging (MSI) referred to as laser ablation and solvent capture by aspiration (LASCA) is presented and its performance demonstrated using selected, unaltered biological materials. LASCA employs a pulsed 2.94 μm laser beam for specimen ablation. Ablated materials in the laser plumes are collected on a hanging solvent droplet with electric field-enhanced trapping, followed by aspiration of droplets and remaining plume material in the form of a coarse aerosol into a collection capillary. The gas and liquid phases are subsequently separated in a 10 μL-volume separatory funnel, and the solution is analyzed with electrospray ionization in a high mass resolution Q-ToF mass spectrometer. The LASCA system separates the sampling and ionization steps in MSI and combines high efficiencies of laser plume sampling and of electrospray ionization (ESI) with high mass resolution MS. Up to 2000 different compounds are detected from a single ablation spot (pixel). Using the LASCA platform, rapid (6 s per pixel), high sensitivity, high mass-resolution ambient imaging of "as-received" biological material is achieved routinely and reproducibly.
New gas phase inorganic ion cluster species and their atmospheric implications
NASA Technical Reports Server (NTRS)
Maerk, T. D.; Peterson, K. I.; Castleman, A. W., Jr.
1980-01-01
Recent experimental laboratory observations, with high-pressure mass spectroscopy, have revealed the existence of previously unreported species involving water clustered to sodium dimer ions, and alkali metal hydroxides clustered to alkali metal ions. The important implications of these results concerning the existence of such species are here discussed, as well as how from a practical aspect they confirm the stability of certain cluster species proposed by Ferguson (1978) to explain masses recently detected at upper altitudes using mass spectrometric techniques.
Papp, Laszlo; Palcsu, Laszlo; Major, Zoltan; Rinyu, Laszlo; Tóth, Istvan
2012-01-01
This paper describes the procedure followed for noble gas measurements for litres, millilitres and microlitres of water samples in our laboratory, including sample preparation, mass spectrometric measurement procedure, and the complete calibrations. The preparation line extracts dissolved gases from water samples of volumes of 0.2 μ l to 3 l and it separates them as noble and other chemically active gases. Our compact system handles the following measurements: (i) determination of tritium concentration of environmental water samples by the (3)He ingrowth method; (ii) noble gas measurements from surface water and groundwater; and (iii) noble gas measurements from fluid inclusions of solid geological archives (e.g. speleothems). As a result, the tritium measurements have a detection limit of 0.012 TU, and the expectation value (between 1 and 20 TU) is within 0.2 % of the real concentrations with a standard deviation of 2.4 %. The reproducibility of noble gas measurements for water samples of 20-40 ml allows us to determine solubility temperatures by an uncertainty better than 0.5 °C. Moreover, noble gas measurements for tiny water amounts (in the microlitre range) show that the results of the performed calibration measurements for most noble gas isotopes occur with a deviation of less than 2 %. Theoretically, these precisions for noble gas concentrations obtained from measurements of waters samples of a few microlitres allow us to determine noble gas temperatures by an uncertainty of less than 1 °C. Here, we present the first noble gas measurements of tiny amounts of artificial water samples prepared under laboratory conditions.
Headley, John V; Peru, Kerry M; Barrow, Mark P
2016-01-01
There has been a recent surge in the development of mass spectrometric methods for detailed characterization of naphthenic acid fraction compounds (all C(c)H(h)N(n)O(o)S(s), species, including heteroatomic and aromatic components in the acid-extractable fraction) in environmental samples. This surge is driven by the increased activity in oil sands environmental monitoring programs in Canada, the exponential increase in research studies on the isolation and toxicity identification of components in oil sands process water (OSPW), and the analytical requirements for development of technologies for treatment of OSPW. There has been additional impetus due to the parallel studies to control corrosion from naphthenic acids during the mining and refining of heavy bitumen and crude oils. As a result, a range of new mass spectrometry tools have been introduced since our last major review of this topic in 2009. Of particular significance are the developments of combined mass spectrometric methods that incorporate technologies such as gas chromatography, liquid chromatography, and ion mobility. There has been additional progress with respect to improved visualization methods for petroleomics and oil sands environmental forensics. For comprehensive coverage and more reliable characterization of samples, an approach based on multiple-methods that employ two or more ionization modes is recommended. On-line or off-line fractionation of isolated extracts, with or without derivatization, might also be used prior to mass spectrometric analyses. Individual ionization methods have their associated strengths and weaknesses, including biases, and thus dependence upon a single ionization method is potentially misleading. There is also a growing trend to not rely solely on low-resolution mass spectrometric methods (<20,000 resolving power at m/z 200) for characterization of complex samples. Future research is anticipated to focus upon (i) structural elucidation of components to determine the correlation with toxicity or corrosion, (ii) verification of characterization studies based on authentic reference standards and reference materials, and (iii) integrated approaches based on multiple-methods and ionization methods for more-reliable oil sands environmental forensics. © 2015 Wiley Periodicals, Inc.
Shadkami, Farzad; Helleur, Robert
2009-07-31
A simple and direct approach was developed for thermochemolytic analysis of a wide range of biomolecules present in plant materials using an injection port of a gas chromatograph/mass spectrometer (GC/MS) and a novel solids injector consisting of a coiled stainless steel wire placed inside a modified needle syringe. Optimum thermochemolysis (or Thermally Assisted Hydrolysis/Methylation) was achieved by using a suitable methanolic solution of trimethylsulfonium hydroxide (TMSH) or tetramethylammonium hydroxide (TMAH) with an injection port temperature of 350 degrees C. Intact, methylated flavonoids, saccharides, phenolic and fatty acids, lignin dimers and diterpene resin acids were identified. Samples include tea leaves, hemicelluloses, lignin isolates and herbal medicines. Unexpected chromatographic results using TMAH reagent revealed the presence of intact methylated trisaccharides (658 Da) and structurally informative dimer lignin markers.
Structures and physical properties of gaseous metal cationized biological ions.
Burt, Michael B; Fridgen, Travis D
2012-01-01
Metal chelation can alter the activity of free biomolecules by modifying their structures or stabilizing higher energy tautomers. In recent years, mass spectrometric techniques have been used to investigate the effects of metal complexation with proteins, nucleobases and nucleotides, where small conformational changes can have significant physiological consequences. In particular, infrared multiple photon dissociation spectroscopy has emerged as an important tool for determining the structure and reactivity of gas-phase ions. Unlike other mass spectrometric approaches, this method is able to directly resolve structural isomers using characteristic vibrational signatures. Other activation and dissociation methods, such as blackbody infrared radiative dissociation or collision-induced dissociation can also reveal information about the thermochemistry and dissociative pathways of these biological ions. This information can then be used to provide information about the structures of the ionic complexes under study. In this article, we review the use of gas-phase techniques in characterizing metal-bound biomolecules. Particular attention will be given to our own contributions, which detail the ability of metal cations to disrupt nucleobase pairs, direct the self-assembly of nucleobase clusters and stabilize non-canonical isomers of amino acids.
Dantas, Hebertty V; Barbosa, Mayara F; Nascimento, Elaine C L; Moreira, Pablo N T; Galvão, Roberto K H; Araújo, Mário C U
2013-03-15
This paper proposes a NIR spectrometric method for screening analysis of liquefied petroleum gas (LPG) samples. The proposed method is aimed at discriminating samples with low and high propane content, which can be useful for the adjustment of burn settings in industrial applications. A gas flow system was developed to introduce the LPG sample into a NIR flow cell at constant pressure. In addition, a gas chromatographer was employed to determine the propane content of the sample for reference purposes. The results of a principal component analysis, as well as a classification study using SIMCA (soft independent modeling of class analogies), revealed that the samples can be successfully discriminated with respect to propane content by using the NIR spectrum in the range 8100-8800 cm(-1). In addition, by using SPA-LDA (linear discriminant analysis with variables selected by the successive projections algorithm), it was found that perfect discrimination can also be achieved by using only two wavenumbers (8215 and 8324 cm(-1)). This finding may be of value for the design of a dedicated, low-cost instrument for routine analyses. Copyright © 2012 Elsevier B.V. All rights reserved.
Gas Chromatic Mass Spectrometer
NASA Technical Reports Server (NTRS)
Wey, Chowen
1995-01-01
Gas chromatograph/mass spectrometer (GC/MS) used to measure and identify combustion species present in trace concentration. Advanced extractive diagnostic method measures to parts per billion (PPB), as well as differentiates between different types of hydrocarbons. Applicable for petrochemical, waste incinerator, diesel transporation, and electric utility companies in accurately monitoring types of hydrocarbon emissions generated by fuel combustion, in order to meet stricter environmental requirements. Other potential applications include manufacturing processes requiring precise detection of toxic gaseous chemicals, biomedical applications requiring precise identification of accumulative gaseous species, and gas utility operations requiring high-sensitivity leak detection.
Aguilera-Herrador, Eva; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel
2008-10-31
A simple, rapid, solventless method for the determination of trihalomethanes (THMs) (chloroform, bromodichloromethane, dibromochloromethane and bromoform) in water samples is presented. The analytes are extracted from the headspace of the aqueous matrix into a 2 microL drop of the ionic liquid 1-octyl-3-methyl-imidazolium hexafluorophosphate working at 30 degrees C for 30 min. The separation and detection of the target compounds is accomplished by gas chromatography/mass spectrometry owing to the use of an interface that efficiently transfers the analytes extracted in the ionic liquid drop to the gas chromatograph while preventing the ionic liquid from entering the column. The detection limits obtained are below the values compelled by the legislation, ranging from 0.5 microg L(-1) for chloroform and bromodichloromethane to 0.9 microg L(-1) for dibromochloromethane. The use of ionic liquid in the extraction procedure avoids the use of organic solvents and leads to relative standard deviations that range from 3.1% to 4.8%.
Mass spectrometric immunoassay
Nelson, Randall W; Williams, Peter; Krone, Jennifer Reeve
2007-12-04
Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.
Mass spectrometric immunoassay
Nelson, Randall W; Williams, Peter; Krone, Jennifer Reeve
2013-07-16
Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.
Mass spectrometric immunoassay
Nelson, Randall W.; Williams, Peter; Krone, Jennifer Reeve
2005-12-13
Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.
Teunissen, Sebastiaan F; Fedick, Patrick W; Berendsen, Bjorn J A; Nielen, Michel W F; Eberlin, Marcos N; Graham Cooks, R; van Asten, Arian C
2017-12-01
Paper spray tandem mass spectrometry is used to identify and quantify eight individual amphetamines in whole blood in 1.3 min. The method has been optimized and fully validated according to forensic toxicology guidelines, for the quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy-N-methylamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), para-methoxyamphetamine (PMA), para-methoxymethamphetamine (PMMA), and 4-fluoroamphetamine (4-FA). Additionally, a new concept of intrinsic and application-based selectivity is discussed, featuring increased confidence in the power to discriminate the amphetamines from other chemically similar compounds when applying an ambient mass spectrometric method without chromatographic separation. Accuracy was within ±15% and average precision was better than 15%, and better than 20% at the LLOQ. Detection limits between 15 and 50 ng/mL were obtained using only 12 μL of whole blood. Graphical abstract ᅟ.
NASA Astrophysics Data System (ADS)
Teunissen, Sebastiaan F.; Fedick, Patrick W.; Berendsen, Bjorn J. A.; Nielen, Michel W. F.; Eberlin, Marcos N.; Graham Cooks, R.; van Asten, Arian C.
2017-12-01
Paper spray tandem mass spectrometry is used to identify and quantify eight individual amphetamines in whole blood in 1.3 min. The method has been optimized and fully validated according to forensic toxicology guidelines, for the quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy- N-methylamphetamine (MDMA), 3,4-methylenedioxy- N-ethylamphetamine (MDEA), para-methoxyamphetamine (PMA), para-methoxymethamphetamine (PMMA), and 4-fluoroamphetamine (4-FA). Additionally, a new concept of intrinsic and application-based selectivity is discussed, featuring increased confidence in the power to discriminate the amphetamines from other chemically similar compounds when applying an ambient mass spectrometric method without chromatographic separation. Accuracy was within ±15% and average precision was better than 15%, and better than 20% at the LLOQ. Detection limits between 15 and 50 ng/mL were obtained using only 12 μL of whole blood. [Figure not available: see fulltext.
Del Bubba, Massimo; Checchini, Leonardo; Chiuminatto, Ugo; Doumett, Saer; Fibbi, Donatella; Giordani, Edgardo
2012-09-01
High-performance liquid chromatography coupled with ion spray mass spectrometry in the tandem mode with both negative and positive ionization was used for investigating a variety of polyphenolic compounds in four genotypes of Fragaria vesca berries. About 60 phenolic compounds belonging to the compound classes of phenolic acids, ellagitannins, ellagic acid derivatives, flavonols, monomeric and oligomeric flavanols, dihydrochalcones and anthocyanins were reported, providing for the first time a quite complete picture of polyphenolic composition of F. vesca berries. Some of the polyphenols herein investigated, such as a tris-galloyl-hexahydroxydiphenoyl-hexose, two castalagin/vescalagin-like isomers and peonidin-malonylglucoside, were described for the first time. Principal component analysis applied on original HPLC-MS/MS data, acquired in multiple reaction monitoring mode, successfully discriminated the four investigated cultivars on the basis of their polyphenolic composition, highlighting the fundamental role of mass spectrometry for food characterization. Copyright © 2012 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Manicke, Nicholas E.; Belford, Michael
2015-05-01
One limitation in the growing field of ambient or direct analysis methods is reduced selectivity caused by the elimination of chromatographic separations prior to mass spectrometric analysis. We explored the use of high-field asymmetric waveform ion mobility spectrometry (FAIMS), an ambient pressure ion mobility technique, to separate the closely related opiate isomers of morphine, hydromorphone, and norcodeine. These isomers cannot be distinguished by tandem mass spectrometry. Separation prior to MS analysis is, therefore, required to distinguish these compounds, which are important in clinical chemistry and toxicology. FAIMS was coupled to a triple quadrupole mass spectrometer, and ionization was performed using either a pneumatically assisted heated electrospray ionization source (H-ESI) or paper spray, a direct analysis method that has been applied to the direct analysis of dried blood spots and other complex samples. We found that FAIMS was capable of separating the three opiate structural isomers using both H-ESI and paper spray as the ionization source.
Qiu, Xiangjun; Zhao, Jian-Long; Hao, Cong; Yuan, Canli; Tian, Nuan; Xu, Zhi-Sheng; Zou, Ruan-Min
2016-05-30
In this study, a sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed to determine mangiferin and neomangiferin in rat plasma simultaneously. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a Xevo TQD triple quadruple mass spectrometer coupled with an electrospray ionization (ESI) source. The MRM transitions of m/z 423.2 → 303.1 and m/z 585.0 → 273.1 were used to quantify for mangiferin and neomangiferin, respectively. The linearity of this method was found to be within the concentration range of 5-2000 ng/mL for mangiferin, and 2-1000 ng/mL for neomangiferin in rat plasma, respectively. Only 3.0 min was needed for an analytical run. This assay was used to support a preclinical study to investigate the pharmacokinetics of mangiferin and neomangiferin in rats. Copyright © 2016 Elsevier B.V. All rights reserved.
Di Filippo, Patrizia; Riccardi, Carmela; Pomata, Donatella; Marsiglia, Riccardo; Console, Carla; Puri, Daniele
2018-01-01
Fosetyl-aluminum is a synthetic fungicide administered to plants especially to prevent diseases caused by the members of the Peronosporales and several Phytophthora species. Herein, we present a selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze residues of fosetyl-A1 in air particulate matter. This study was performed in perspective of an exposure assessment of this substance of health concern in environments where high levels of fosetly-Al, relatively to airborne particulate matter, can be found after spraying it. The cleanup procedure of the analyte, from sampled filters of atmospheric particulate matter, was optimized using a Strata X solid-phase extraction cartridge, after accelerated extraction by using water. The chromatographic separation was achieved using a polymeric column based on hydrophilic interaction in step elution with water/acetonitrile, whereas the mass spectrometric detection was performed in negative electrospray ionization. The proposed method resulted to be a simple, fast, and suitable method for confirmation purposes. PMID:29686933
Huston, John L.; Scott, Robert G.; Studier, Martin H.
1978-01-01
Coal is fluorinated by contact with fluorine gas at low pressure. After pial fluorination, when the reaction rate has slowed, the pressure is slowly increased until fluorination is complete, forming a solid fluorinated coal of approximate composition CF.sub.1.55 H.sub.0.15. The fluorinated coal and a solid distillate resulting from vacuum pyrolysis of the fluorinated coal are useful as an internal standard for mass spectrometric unit mass assignments from about 100 to over 1500.
J. M. Roberts; P. Veres; C. Warneke; J. A. Neuman; R. A. Washenfelder; S. S. Brown; M. Baasandorj; J. B. Burkholder; I. R. Burling; T. J. Johnson; R. J. Yokelson; J. de Gouw
2010-01-01
A negative-ion proton transfer chemical ionization mass spectrometric technique (NI-PT-CIMS), using acetate as the reagent ion, was applied to the measurement of volatile inorganic acids of atmospheric interest: hydrochloric (HCl), nitrous (HONO), nitric 5 (HNO3), and isocyanic (HNCO) acids. Gas phase calibrations through the sampling inlet showed the method to be...
Instrumentation for Measurement of Gas Permeability of Polymeric Membranes
NASA Technical Reports Server (NTRS)
Upchurch, Billy T.; Wood, George M.; Brown, Kenneth G.; Burns, Karen S.
1993-01-01
A mass spectrometric 'Dynamic Delta' method for the measurement of gas permeability of polymeric membranes has been developed. The method is universally applicable for measurement of the permeability of any gas through polymeric membrane materials. The usual large sample size of more than 100 square centimeters required for other methods is not necessary for this new method which requires a size less than one square centimeter. The new method should fulfill requirements and find applicability for industrial materials such as food packaging, contact lenses and other commercial materials where gas permeability or permselectivity properties are important.
2014-01-01
This review aims to highlight the recent advances and methodological improvements in instrumental techniques applied for the analysis of different brominated flame retardants (BFRs). The literature search strategy was based on the recent analytical reviews published on BFRs. The main selection criteria involved the successful development and application of analytical methods for determination of the target compounds in various environmental matrices. Different factors affecting chromatographic separation and mass spectrometric detection of brominated analytes were evaluated and discussed. Techniques using advanced instrumentation to achieve outstanding results in quantification of different BFRs and their metabolites/degradation products were highlighted. Finally, research gaps in the field of BFR analysis were identified and recommendations for future research were proposed. PMID:27433482
Villberg, K; Veijanen, A
2001-03-01
A thermal desorption equipment introducing volatile organic compounds (VOCs) into the gas chromatographic/ mass spectrometric system (GC/MS) with simultaneous sniffing (SNIFF) is a suitable method for identifying the volatile organic off-odor compounds formed during the extrusion coating process of low-density polyethylene. Fumes emitted during the extrusion coating process of three different plastic materials were collected at two different temperatures (285 and 315 degrees C) from an outgoing pipe and near an extruder. The VOCs of fumes were analyzed by drawing a known volume of air through the adsorbent tube filled with a solid adsorbent (Tenax GR). The air samples were analyzed by using a special thermal desorption device and GC/MS determination. The simultaneous sniffing was carried out to detect off-odors and to assist in the identification of those compounds that contribute to tainting and smelling. The amounts of off-odor carbonyl compounds and the total content of the volatile organic compounds were determined. The most odorous compounds were identified as carboxylic acids while the majority of the volatile compounds were hydrocarbons. The detection and quantification of carboxylic acids were based on the characteristic ions of their mass spectra. The higher the extrusion temperature the more odors were detected. An important observation was that the total concentration of volatiles was dependent not only on the extrusion temperature but also on the plastic material.
Ramasamy, Sugumar; Arumugam, Arumugam; Chandran, Preethy
2017-02-01
Efficiency of Enterobacter cloacae KU923381 isolated from petroleum hydrocarbon contaminated soil was evaluated in batch culture and bioreactor mode. The isolate were screened for biofilm formation using qualitative and quantitative assays. Response surface methodology (RSM) was used to study the effect of pH, temperature, glucose concentration, and sodium chloride on diesel degradation. The predicted values for diesel oil degradation efficiency by the statistical designs are in a close agreement with experimental data (R 2 = 99.66%). Degradation efficiency is increased by 36.78% at pH = 7, temperature = 35°C, glucose = 5%, and sodium chloride concentration = 5%. Under the optimized conditions, the experiments were performed for diesel oil degradation by gas chromatographic mass spectrometric analysis (GC-MS). GC-MS analysis confirmed that E. cloacae had highly degrade hexadecane, heptadecane, tridecane, and docosane by 99.71%, 99.23%, 99.66%, and 98.34% respectively. This study shows that rapid bioremoval of hydrocarbons in diesel oil is acheived by E. cloacae with abet of biofilm formation. The potential use of the biofilms for preparing trickling filters (gravel particles) for the degradation of hydrocarbons from petroleum wastes before their disposal in the open environment is highly suggested. This is the first successful attempt for artificially establishing petroleum hydrocarbon degrading bacterial biofilm on solid substrates in bioreactor.
Gao, L N; Yuan, H Y; Xu, E Y; Liu, J T
2017-12-01
To establish a gas chromatographic-mass spectrometric (GC-MS) analysis method for quantifying 1-methylhydantoin concentration in whole blood. To provide technical support to forensic identification related cases of 1-methylhydantoin. As an internal standard, 500 ng SKF 525A was added to 0.5 mL blood sample, and then 2 mL 0.01 mol/L dilute hydrochloric acid and 0.5 g ammonium carbonate were added in order to buffer the pH value to 9, and following 2 mL ethyl acetate. The organic solvent layer was obtained after centrifuge and then analysed by GC-MS after drying. Good linear relationship of 1-methylhydantoin in blood was obtained in the range of 0.5-50 ng/mL. The equation of linear regression was y =0.015 51 x +0.007 26( R ²=0.999 7) with 0.1 ng/mL detection limit, and the recovery was 93.02%-108.12%. The intra-day and inter-day precision were less than 6.07% and 13.37%, respectively. The results gotten by this method is accurate and reproducible, which can be used for the determination of 1-methylhydantoin concentration in blood samples. Copyright© by the Editorial Department of Journal of Forensic Medicine
Composition of estuarine colloidal material: organic components
Sigleo, A.C.; Hoering, T.C.; Helz, G.R.
1982-01-01
Colloidal material in the size range 1.2 nm to 0.4 ??m was isolated by ultrafiltration from Chesapeake Bay and Patuxent River waters (U.S.A.). Temperature controlled, stepwise pyrolysis of the freeze-dried material, followed by gas chromatographic-mass spectrometric analyses of the volatile products indicates that the primary organic components of this polymer are carbohydrates and peptides. The major pyrolysis products at the 450??C step are acetic acid, furaldehydes, furoic acid, furanmethanol, diones and lactones characteristic of carbohydrate thermal decomposition. Pyrroles, pyridines, amides and indole (protein derivatives) become more prevalent and dominate the product yield at the 600??C pyrolysis step. Olefins and saturated hydrocarbons, originating from fatty acids, are present only in minor amounts. These results are consistent with the composition of Chesapeake phytoplankton (approximately 50% protein, 30% carbohydrate, 10% lipid and 10% nucleotides by dry weight). The pyrolysis of a cultured phytoplankton and natural particulate samples produced similar oxygen and nitrogencontaining compounds, although the proportions of some components differ relative to the colloidal fraction. There were no lignin derivatives indicative of terrestrial plant detritus in any of these samples. The data suggest that aquatic microorganisms, rather than terrestrial plants, are the dominant source of colloidal organic material in these river and estuarine surface waters. ?? 1982.
Cytotoxicity of the Essential Oil of Fennel (Foeniculum vulgare) from Tajikistan
Valiev, Abdujabbor; Satyal, Prabodh; Gulmurodov, Isomiddin; Yusufi, Salomudin; Setzer, William N.
2017-01-01
The essential oil of fennel (Foeniculum vulgare) is rich in lipophilic secondary metabolites, which can easily cross cell membranes by free diffusion. Several constituents of the oil carry reactive carbonyl groups in their ring structures. Carbonyl groups can react with amino groups of amino acid residues in proteins or in nucleotides of DNA to form Schiff’s bases. Fennel essential oil is rich in anise aldehyde, which should interfere with molecular targets in cells. The aim of the present study was to investigate the chemical composition of the essential oil of fennel growing in Tajikistan. Gas chromatographic-mass spectrometric analysis revealed that the main components of F. vulgare oil were trans-anethole (36.8%); α-ethyl-p-methoxy-benzyl alcohol (9.1%); p-anisaldehyde (7.7%); carvone (4.9%); 1-phenyl-penta-2,4-diyne (4.8%) and fenchyl butanoate (4.2%). The oil exhibited moderate antioxidant activities. The potential cytotoxic activity was studied against HeLa (human cervical cancer), Caco-2 (human colorectal adenocarcinoma), MCF-7 (human breast adenocarcinoma), CCRF-CEM (human T lymphoblast leukaemia) and CEM/ADR5000 (adriamycin resistant leukaemia) cancer cell lines; IC50 values were between 30–210 mg L−1 and thus exhibited low cytotoxicity as compared to cytotoxic reference compounds. PMID:28846628
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watts, V.W.; Caplan, Y.H.
The Coat-A-Count solid phase {sup 125}I Fentanyl Radioimmunoassay was evaluated with respect to linearity and precision using equine urine fortified with fentanyl and then compared with a gas chromatographic/mass spectrometric method for quantification of fentanyl in urine. The RIA assay was found to be linear over the urine fentanyl concentration range of 0.25 to 7.5 ng/mL and precise with coefficients of variation (CV) ranging from 9.6 to 19.3%. The RIA calibrators, ranging in fentanyl concentrations from 0.25 to 7.5 ng/mL, and controls, at mean fentanyl concentrations of 0.46 and 1.32 ng/mL, were compared by both the RIA and GC/MS methods.more » The cross-reactivity with the {sup 125}I RIA test was determined for the fentanyl metabolites, norfentanyl and hydroxyfentanyl, and found to be 5% and 35%, respectively. The illicit fentanyl analogs were found to show significant cross-reactivity, ranging from 20 to 100%. The {sup 125}I RIA was compared to GC/MS quantifications of fentanyl in 35 positive and 20 negative case urine specimens.« less
Bonaduce, Ilaria; Brecoulaki, Hariclia; Colombini, Maria Perla; Lluveras, Anna; Restivo, Vincenzo; Ribechini, Erika
2007-12-21
This paper presents an analytical GC-MS procedure to study the chemical composition of plant gums, determining aldoses and uronic acids in one step. The procedure is based on the silylation of aldoses and uronic acids, released from plant gums by microwave assisted hydrolysis, and previously converted into the corresponding diethyl-dithioacetals and diethyl-dithioacetal lactones. Using this method only one peak for each compound is obtained, thus providing simple and highly reproducible chromatograms. The analytical procedure was optimised using reference samples of raw plant gums (arabic, karaya, ghatti, guar, locust bean and tragacanth, cherry, plum and peach gums), commercial watercolours and paint layers prepared according to ancient recipes at the Opificio delle Pietre Dure of Florence (Italy). To identify gum media in samples of unknown composition, a decisional schema for the gum identification and the principal component analysis of the relative sugar percentage contents were employed. The procedure was used to study samples collected from wall paintings from Macedonian tombs (4th-3rd centuries bc) and from the Mycenaean "Palace of Nestor" (13th century bc) in Pylos, Greece. The presence of carbohydrates was ascertained and plant gum binders (fruit and a mixture of tragacanth and fruit tree gums) were identified in some of the samples.
Stout, Peter R; Horn, Carl K; Klette, Kevin L
2002-01-01
To facilitate analysis of high sample volumes, an extraction, derivatization and gas chromatographic-mass spectrometric analysis method was developed to simultaneously determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxyamphetamine (MDA) 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDEA) in urine. This method utilized a positive-pressure manifold cation-exchange polymer-based solid-phase extraction followed by elution directly into automated liquid sampler (ALS) vials. Rapid derivatization was accomplished using heptafluorobutyric anhydride (HFBA). Recoveries averaged 90% or greater for each of the compounds. Limits of detection were 62.5 ng/mL (AMP and MDEA), 15.6 ng/mL (MAMP), and 31.3 ng/mL (MDA and MDMA) using a 2-mL sample volume. The method was linear to 5000 ng/mL for all compounds using MDMA-d5 and MAMP-d14 as internal standards. Over 200 human urine samples previously determined to contain the target analytes were analyzed using the method. Excellent agreement was seen with previous quantitations. The method was challenged with 75 potentially interfering compounds and no interferences were seen. These interfering compounds included ephedrine, pseudoephedrine, phenylpropanolamine, and phenethylamine. The method resulted in dramatic reductions in processing time and waste production.
Parastar, Hadi; Radović, Jagoš R; Bayona, Josep M; Tauler, Roma
2013-07-01
Multivariate curve resolution-alternating least squares (MCR-ALS) analysis is proposed to solve chromatographic challenges during two-dimensional gas chromatography-time-of-flight mass spectrometry (GC × GC-TOFMS) analysis of complex samples, such as crude oil extract. In view of the fact that the MCR-ALS method is based on the fulfillment of the bilinear model assumption, three-way and four-way GC × GC-TOFMS data are preferably arranged in a column-wise superaugmented data matrix in which mass-to-charge ratios (m/z) are in its columns and the elution times in the second and first chromatographic columns are in its rows. Since m/z values are common for all measured spectra in all second-column modulations, unavoidable chromatographic challenges such as retention time shifts within and between GC × GC-TOFMS experiments are properly handled. In addition, baseline/background contributions can be modeled by adding extra components to the MCR-ALS model. Another outstanding aspect of MCR-ALS analysis is its extreme flexibility to consider all samples (standards, unknowns, and replicates) in a single superaugmented data matrix, allowing joint analysis. In this way, resolution, identification, and quantification results can be simultaneously obtained in a very fast and reliable way. The potential of MCR-ALS analysis is demonstrated in GC × GC-TOFMS analysis of a North Sea crude oil extract sample with relative errors in estimated concentrations of target compounds below 6.0 % and relative standard deviations lower than 7.0 %. The results obtained, along with reasonable values for the lack of fit of the MCR-ALS model and high values of the reversed match factor in mass spectra similarity searches, confirm the reliability of the proposed strategy for GC × GC-TOFMS data analysis.
Aznar, Margarita; Arroyo, Teresa
2007-09-21
The purge-and-trap extraction method, coupled to a gas chromatograph with mass spectrometry detection, has been applied to the determination of 26 aromatic volatiles in wine. The method was optimized, validated and applied to the analyses of 40 red and white wines from 7 different Spanish regions. Principal components analyses of data showed the correlation between wines of similar origin.
Bean, Heather D.; Hill, Jane E.; Dimandja, Jean-Marie D.
2015-01-01
The potential of high-resolution analytical technologies like GC×GC/TOF MS in untargeted metabolomics and biomarker discovery has been limited by the development of fully automated software that can efficiently align and extract information from multiple chromatographic data sets. In this work we report the first investigation on a peak-by-peak basis of the chromatographic factors that impact GC×GC data alignment. A representative set of 16 compounds of different chromatographic characteristics were followed through the alignment of 63 GC×GC chromatograms. We found that varying the mass spectral match parameter had a significant influence on the alignment for poorly- resolved peaks, especially those at the extremes of the detector linear range, and no influence on well- chromatographed peaks. Therefore, optimized chromatography is required for proper GC×GC data alignment. Based on these observations, a workflow is presented for the conservative selection of biomarker candidates from untargeted metabolomics analyses. PMID:25857541
Barregard, Lars; Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J; Weimann, Allan; Poulsen, Henrik E; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J; Santella, Regina M; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen; Cooke, Marcus S
2013-06-20
Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed 'spot' samples showed strong correlations with 24 h excretion (the 'gold' standard) of urinary 8-oxodG (rp 0.67-0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended.
Meng, Xiangpeng; Tong, Tong; Wang, Lianrong; Liu, Hanxia; Chan, Wan
2016-05-01
2-Alkylcyclobutanones (2-ACBs) are uniquely formed when triglycerides-containing food products are exposed to ionizing radiation. Thus, 2-ACBs have been used as marker molecules to identify irradiated food. Most methods to determine 2-ACBs involve mass spectrometric detection after chromatographic separation. The spectrofluorometer is rarely used to determine 2-ACBs because these molecules do not fluoresce. In this study, we developed an ultra-performance liquid chromatography (UPLC) method to determine 2-ACBs. 2-ACBs were converted into fluorophores after reacting with 1-naphthalenyl hydrazine to facilitate their sensitive and selective detection using a fluorescence detector (FLD). Analysis of 2-ACBs using our developed UPLC-FLD method allows sensitive determination of 2-ACBs at a detection limit of 2 ng 2-ACBs per g of fat (30 pg/injection), which is significantly lower than that of existing analytical methods. After validation for trueness and precision, the method was applied to γ-irradiated chicken samples to determine their 2-ACB content. Comparative studies employing liquid chromatography-tandem mass spectrometric method revealed no systematic difference between the two methods, thereby demonstrating that the proposed UPLC-FLD method can be suitably used to determine 2-ACBs in irradiated foodstuffs. Graphical Abstract Determination of radiation-induced food-borne 2-dodecylcyclobutanone and 2-tetradecylcyclobutanone by combining 1-naphthalenyl hydrazine derivatization and ultra-performance liquid chromatography with fluorescence detection.
Gras, Ronda; Luong, Jim; Haddad, Paul R; Shellie, Robert A
2018-05-08
An effective analytical strategy was developed and implemented to exploit the synergy derived from three different detector classes for gas chromatography, namely ultraviolet spectroscopy, flame ionization, and mass spectrometry for volatile compound analysis. This strategy was achieved by successfully hyphenating a user-selectable multi-wavelength diode array detector featuring a positive temperature coefficient thermistor as an isothermal heater to a gas chromatograph. By exploiting the non-destructive nature of the diode array detector, the effluent from the detector was split to two parallel detectors; namely a quadrupole mass spectrometer and a flame ionization detector. This multi-hyphenated configuration with the use of three detectors is a powerful approach not only for selective detection enhancement but also for improvement in structural elucidation of volatile compounds where fewer fragments can be obtained or for isomeric compound analysis. With the diode array detector capable of generating high resolution gas phase spectra, the information collected provides useful confirmatory information without a total dependence on the chromatographic separation process which is based on retention time. This information-rich approach to chromatography is achieved without incurring extra analytical time, resulting in improvements in compound identification accuracy, analytical productivity, and cost. Chromatographic performance obtained from model compounds was found to be acceptable with a relative standard deviation of the retention times of less than 0.01% RSD, and a repeatability at two levels of concentration of 100 and 1000 ppm (v/v) of less than 5% (n = 10). With this configuration, correlation of data between the three detectors was simplified by having near identical retention times for the analytes studied. Copyright © 2018 Elsevier B.V. All rights reserved.
Recent Advances in Water Analysis with Gas Chromatograph Mass Spectrometers
NASA Technical Reports Server (NTRS)
MacAskill, John A.; Tsikata, Edem
2014-01-01
We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.
Mistarz, Ulrik H; Brown, Jeffery M; Haselmann, Kim F; Rand, Kasper D
2014-12-02
Gas-phase hydrogen/deuterium exchange (HDX) is a fast and sensitive, yet unharnessed analytical approach for providing information on the structural properties of biomolecules, in a complementary manner to mass analysis. Here, we describe a simple setup for ND3-mediated millisecond gas-phase HDX inside a mass spectrometer immediately after ESI (gas-phase HDX-MS) and show utility for studying the primary and higher-order structure of peptides and proteins. HDX was achieved by passing N2-gas through a container filled with aqueous deuterated ammonia reagent (ND3/D2O) and admitting the saturated gas immediately upstream or downstream of the primary skimmer cone. The approach was implemented on three commercially available mass spectrometers and required no or minor fully reversible reconfiguration of gas-inlets of the ion source. Results from gas-phase HDX-MS of peptides using the aqueous ND3/D2O as HDX reagent indicate that labeling is facilitated exclusively through gaseous ND3, yielding similar results to the infusion of purified ND3-gas, while circumventing the complications associated with the use of hazardous purified gases. Comparison of the solution-phase- and gas-phase deuterium uptake of Leu-Enkephalin and Glu-Fibrinopeptide B, confirmed that this gas-phase HDX-MS approach allows for labeling of sites (heteroatom-bound non-amide hydrogens located on side-chains, N-terminus and C-terminus) not accessed by classical solution-phase HDX-MS. The simple setup is compatible with liquid chromatography and a chip-based automated nanoESI interface, allowing for online gas-phase HDX-MS analysis of peptides and proteins separated on a liquid chromatographic time scale at increased throughput. Furthermore, online gas-phase HDX-MS could be performed in tandem with ion mobility separation or electron transfer dissociation, thus enabling multiple orthogonal analyses of the structural properties of peptides and proteins in a single automated LC-MS workflow.
Gaiffe, Gabriel; Bridoux, Maxime C; Costanza, Christine; Cole, Richard B
2018-01-01
The development of rapid, efficient, and reliable detection methods for the characterization of energetic compounds is of high importance to security forces concerned with terrorist threats. With a mass spectrometric approach, characteristic ions can be produced by attaching anions to analyte molecules in the negative ion mode of electrospray ionization mass spectrometry (ESI-MS). Under optimized conditions, formed anionic adducts can be detected with higher sensitivities as compared with the deprotonated molecules. Fundamental aspects pertaining to the formation of anionic adducts of 1,3,5,7-tetranitro-1,3,5,7-tetrazocane (HMX), 1,3,5-trinitro-1,3,5-triazinane (RDX), pentaerythritol tetranitrate (PETN), nitroglycerin (NG), and 1,3,5-trinitroso-1,3,5-triazinane energetic (R-salt) compounds using various anions have been systematically studied by ESI-MS and ESI tandem mass spectrometry (collision-induced dissociation) experiments. Bracketing method results show that the gas-phase acidities of PETN, RDX, and HMX fall between those of HF and acetic acid. Moreover, PETN and RDX are each less acidic than HMX in the gas phase. Nitroglycerin was found to be the most acidic among the nitrogen-rich explosives studied. The ensemble of bracketing results allows the construction of the following ranking of gas-phase acidities: PETN (1530-1458 kJ/mol) > RDX (approximately 1458 kJ/mol) > HMX (approximately 1433 kJ/mol) > nitroglycerin (1427-1327.8 kJ/mol). Copyright © 2017 John Wiley & Sons, Ltd.
USDA-ARS?s Scientific Manuscript database
Supercritical fluid chromatography was used to resolve and determine ginkgolic acids (GAs) and terpene lactones concurrently in ginkgo plant materials and commercial dietary supplements. Analysis of GAs (C13:0, C15:0, C15:1 and C17:1) was carried out by ESI (-) mass detection. The ESI (-) spectra of...
Use of a temperature-programmable pre-separation column in the gas chromatographic injection port permits determination of a wide range of semi-volatile pesticides including organochlorines, organophosphates, triazines, and anilines in fatty composite dietary samples while reduci...
Lucentini, Luca; Ferretti, Emanuele; Veschetti, Enrico; Achene, Laura; Turrio-Baldassarri, Luigi; Ottaviani, Massimo; Bogialli, Sara
2009-01-01
A simple and sensitive liquid chromatographic-tandem mass spectrometric (LC/MS/MS) method has been developed and validated to confirm and quantify acrylamide monomer (AA) in drinking water using [13C3] acrylamide as internal standard (IS). After a preconcentration by solid-phase extraction with spherical activated carbon, analytes were chromatographed on IonPac ICE-AS1 column (9 x 250 mm) under isocratic conditions using acetonitrile-water-0.1 M formic acid (43 + 52 + 5, v/v/v) as the mobile phase. Analysis was achieved using a triple-quadrupole mass analyzer equipped with a turbo ion spray interface. For confirmation and quantification of the analytes, MS data acquisition was performed in the multireaction monitoring mode, selecting 2 precursor ion to product ion transitions for both AA and IS. The method was validated for linearity, sensitivity, accuracy, precision, extraction efficiency, and matrix effect. Linearity in tap water was observed over the concentration range 0.1-2.0 microg/L. Limits of detection and quantification were 0.02 and 0.1 microg/L, respectively. Interday and intraday assays were performed across 3 validation levels (0.1, 0.5, and 1.5 microg/L). Accuracy (as mean recovery) ranged from 89.3 to 96.2% with relative standard deviation <7.98%. Performance characteristics of this LC/MS/MS method make it suitable for regulatory confirmatory analysis of AA in drinking water in compliance with European Union and U.S. Environmental Protection Agency standards.
None
2018-01-16
NETL is committed to providing its researchers with the latest scientific equipment. This video highlights three technologies: the Beowulf Cluster supercomputer, the OASIS Surface Analytical and Imaging System, and the gas chromatograph-inductively coupled plasma-mass spectrometer, or GC-ICP-MS.
Jiang, Zhenzuo; Liu, Yanan; Zhu, Yan; Yang, Jing; Sun, Lili; Chai, Xin; Wang, Yuefei
2016-09-01
Human milk, infant formula, pure milk and fermented milk as food products or dietary supplements provide a range of nutrients required to both infants and adults. Recently, a growing body of evidence has revealed the beneficial roles of short-chain fatty acids (SCFAs), a subset of fatty acids produced from the fermentation of dietary fibers by gut microbiota. The objective of this study was to establish a chromatographic fingerprint technique to investigate SCFAs in human milk and dairy products by gas chromatography coupled with mass spectrometry. The multivariate method for principal component analysis assessed differences between milk types. Human milk, infant formula, pure milk and fermented milk were grouped independently, mainly because of differences in formic acid, acetic acid, propionic acid and hexanoic acid levels. This method will be important for the assessment of SCFAs in human milk and various dairy products.
Van Nimmen, Nadine F J; Veulemans, Hendrik A F
2004-05-07
A highly sensitive gas chromatographic-mass spectrometric (GC-MS) analytical method for the determination of the opioid narcotics fentanyl, alfentanil, and sufentanil in industrial hygiene personal air samples and surface contamination wipes was developed and comprehensively validated. Sample preparation involved a single step extraction of the samples with methanol, fortified with a fixed amount of the penta-deuterated analogues of the opioid narcotics as internal standard. The GC-MS analytical procedure using selected ion monitoring (SIM) was shown to be highly selective. Linearity was shown for levels of extracted wipe and air samples corresponding to at least 0.1-2 times their surface contamination limit (SCL) and accordingly to 0.1-2 times their time weighted average occupational exposure limit (OEL-TWA) based on a full shift 9601 air sample. Extraction recoveries were determined for spiked air samples and surface wipes and were found to be quantitative for both sampling media in the entire range studied. The air sampling method's limit of detection (LOD) was determined to be 0.4 ng per sample for fentanyl and sufentanil and 1.6 ng per sample for alfentanil, corresponding to less than 1% of their individual OEL for a full shift air sample (9601). The limit of quantification (LOQ) was found to be 1.4, 1.2, and 5.0 ng per filter for fentanyl, sufentanil, and alfentanil, respectively. The wipe sampling method had LODs of 4 ng per wipe for fentanyl and sufentanil and 16 ng per wipe for alfentanil and LOQs of respectively, 14, 12, and 50 ng per wipe. The analytical intra-assay precision of the air sampling and wipe sampling method, defined as the coefficient of variation on the analytical result of six replicate spiked media was below 10 and 5%, respectively, for all opioids at all spike levels. Accuracy expressed as relative error was determined to be below 10%, except for alfentanil at the lowest spike level (-13.1%). The stability of the opioids during simulated air sampling was investigated. For fentanyl and sufentanil a quantitative recovery was observed at all spike levels, while for alfentanil recoveries ranged from 60.3 to 85.4%. When spiked air samples were stored at ambient temperature and at -15 degrees C quantitative recovery was found for fentanyl and sufentanil after 7 and 14 days. For alfentanil a slight loss seemed to occur upon storage during 7 days, being more explicit after 14 days. Ambient storage of spiked wipes seemed to lead to significant losses of all opioids studied, yielding recoveries of 37.7-88.3%. Upon storage of similar wipes at -15 degrees C a significantly higher recovery was found ranging from 77.3 to 88.3%. The developed analytical and sampling procedures have been recently applied in an explorative field study of which the results of surface contamination wipe sampling are presented in this paper. To our knowledge, this is the first study addressing the development and validation of analytical procedures for the assessment of external occupational exposure to potent opioid narcotics.
A new LC-MS/MS bioanalytical method for perindopril and perindoprilat in human plasma and milk.
Lwin, Ei Mon Phyo; Gerber, Cobus; Song, Yunmei; Leggett, Catherine; Ritchie, Usha; Turner, Sean; Garg, Sanjay
2017-10-01
A first of its kind, simple, rapid, and sensitive liquid chromatography mass spectrometry (LC-MS/MS) method was developed and validated for quantification of perindopril and perindoprilat in both human plasma and breast milk. The analytes and internal standards (phenazone and acetyl salicylic acid) were extracted from biological matrices by protein precipitation. A Phenomenex® C-18 column was used to provide an appropriate chromatographic separation of the analytes, followed by detection with tandem mass spectrometry. Gradient chromatographic and mass spectrometric detection conditions with mobile phases (A: 5% methanol + 0.1% formic acid in water v/v, and B: 95% methanol + 0.1% formic acid in water v/v) were developed to achieve a LOQ of 0.5 ng/mL in both human plasma and milk. The method was suitable of evaluating clinical samples. The mass transition was followed as m/z 369.10/172.00 for perindopril, m/z 339.00/168.10 for perindoprilat, m/z 188.90/55.95 for phenazone, and m/z 179.04/137.02 for acetyl salicylic acid. The developed method was optimized and validated with a linear range of 0.1-200 ng/mL (r 2 = better than 0.99 for both perindopril and perindoprilat). The precision and accuracy values were within 15% CV. The overall recovery of the analytes was 80-110%. The method has good specificity and repeatability. Stability studies were conducted in both human plasma and bovine milk for up to 3 months, at the storage conditions of 25, 4, and -80 °C.
Acquisition and processing of data for isotope-ratio-monitoring mass spectrometry
NASA Technical Reports Server (NTRS)
Ricci, M. P.; Merritt, D. A.; Freeman, K. H.; Hayes, J. M.
1994-01-01
Methods are described for continuous monitoring of signals required for precise analyses of 13C, 18O, and 15N in gas streams containing varying quantities of CO2 and N2. The quantitative resolution (i.e. maximum performance in the absence of random errors) of these methods is adequate for determination of isotope ratios with an uncertainty of one part in 10(5); the precision actually obtained is often better than one part in 10(4). This report describes data-processing operations including definition of beginning and ending points of chromatographic peaks and quantitation of background levels, allowance for effects of chromatographic separation of isotopically substituted species, integration of signals related to specific masses, correction for effects of mass discrimination, recognition of drifts in mass spectrometer performance, and calculation of isotopic delta values. Characteristics of a system allowing off-line revision of parameters used in data reduction are described and an algorithm for identification of background levels in complex chromatograms is outlined. Effects of imperfect chromatographic resolution are demonstrated and discussed and an approach to deconvolution of signals from coeluting substances described.
An inverse gas chromatographic methodology for studying gas-liquid mass transfer.
Paloglou, A; Martakidis, K; Gavril, D
2017-01-13
A novel methodology of reversed flow inverse gas chromatography (RF-IGC) is presented. It permits the simultaneous determination of mass transfer coefficients across the gas liquid interface as well as the respective solubility parameters and thermodynamic functions of dissolution of gases into liquids. The standard deviation of the experimentally determined parameters is estimated for first time, which combined with the successful comparison of the values of the present parameters with other literature ones ascertain the reliability of the methodology. Another novelty of the present work is that the chromatographic sampling of the physicochemical phenomena is done without performing the usual flow reversals procedure. Vinyl chloride monomer's (VCM) interaction with various composition liquid foods: orange juice, milk and olive oil was used as model system. The present transfer rates are controlled by the gas film at lower temperatures, but at higher temperatures the resistances in both films tend to become equal. The found liquid diffusivity values express the total mass transfer from the gas phase into the liquid's bulk and they decrease with rising temperature, as the solubilities of gases in liquids do. Solubility, expressed by Henry's law constant and the mean values of interfacial thickness are of the same order of magnitude to literature ones. From the thermodynamic point of view, VCM dissolution in all liquids is accompanied by significant heat release and it is a slightly non-spontaneous process, near equilibrium, while the entropy change values are negative. Copyright © 2016 Elsevier B.V. All rights reserved.
High-efficiency high performance liquid chromatographic analysis of red wine anthocyanins.
de Villiers, André; Cabooter, Deirdre; Lynen, Frédéric; Desmet, Gert; Sandra, Pat
2011-07-22
The analysis of anthocyanins in natural products is of significant relevance in recent times due to the recognised health benefits associated with their consumption. In red grapes and wines in particular, anthocyanins are known to contribute important properties to the sensory (colour and taste), anti-oxidant- and ageing characteristics. However, the detailed investigation of the alteration of these compounds during wine ageing is hampered by the challenges associated with the separation of grape-derived anthocyanins and their derived products. High performance liquid chromatography (HPLC) is primarily used for this purpose, often in combination with mass spectrometric (MS) detection, although conventional HPLC methods provide incomplete resolution. We have previously demonstrated how on-column inter-conversion reactions are responsible for poor chromatographic efficiency in the HPLC analysis of anthocyanins, and how an increase in temperature and decrease in particle size may improve the chromatographic performance. In the current contribution an experimental configuration for the high efficiency analysis of anthocyanins is derived using the kinetic plot method (KPM). Further, it is shown how analysis under optimal conditions, in combination with MS detection, delivers much improved separation and identification of red wine anthocyanins and their derived products. This improved analytical performance holds promise for the in-depth investigation of these influential compounds in wine during ageing. Copyright © 2011 Elsevier B.V. All rights reserved.
Fu, Hai-Yan; Guo, Jun-Wei; Yu, Yong-Jie; Li, He-Dong; Cui, Hua-Peng; Liu, Ping-Ping; Wang, Bing; Wang, Sheng; Lu, Peng
2016-06-24
Peak detection is a critical step in chromatographic data analysis. In the present work, we developed a multi-scale Gaussian smoothing-based strategy for accurate peak extraction. The strategy consisted of three stages: background drift correction, peak detection, and peak filtration. Background drift correction was implemented using a moving window strategy. The new peak detection method is a variant of the system used by the well-known MassSpecWavelet, i.e., chromatographic peaks are found at local maximum values under various smoothing window scales. Therefore, peaks can be detected through the ridge lines of maximum values under these window scales, and signals that are monotonously increased/decreased around the peak position could be treated as part of the peak. Instrumental noise was estimated after peak elimination, and a peak filtration strategy was performed to remove peaks with signal-to-noise ratios smaller than 3. The performance of our method was evaluated using two complex datasets. These datasets include essential oil samples for quality control obtained from gas chromatography and tobacco plant samples for metabolic profiling analysis obtained from gas chromatography coupled with mass spectrometry. Results confirmed the reasonability of the developed method. Copyright © 2016 Elsevier B.V. All rights reserved.
Cheng, Hefa; Reinhard, Martin
2010-07-15
Desorption of hydrophobic organic compounds from micropores is characteristically slow compared to surface adsorption and partitioning. The slow-desorbing mass of a hydrophobic probe molecule can be used to calculate the hydrophobic micropore volume (HMV) of microporous solids. A gas chromatographic apparatus is described that allows characterization of the sorbed mass with respect to the desorption rate. The method is demonstrated using a dealuminated zeolite and an aquifer sand as the model and reference sorbents, respectively, and trichloroethylene (TCE) as the probe molecule. A glass column packed with the microporous sorbent is coupled directly to a gas chromatograph that is equipped with flame ionization and electron capture detectors. Sorption and desorption of TCE on the sorbent was measured by sampling the influent and effluent of the column using a combination of switching and injection valves. For geosorbents, the HMV is quantified based on Gurvitsch's rule from the mass of TCE desorbed at a rate that is characteristic for micropores. Instrumental requirements, design considerations, hardware details, detector calibration, performance, and data analysis are discussed along with applications. The method is novel and complements traditional vacuum gravimetric and piezometric techniques, which quantify the total pore volume under vacuum conditions. The HMV is more relevant than the total micropore volume for predicting the fate and transport of organic contaminants in the subsurface. Sorption in hydrophobic micropores strongly impacts the mobility of organic contaminants, and their chemical and biological transformations. The apparatus can serve as a tool for characterizing microporous solids and investigating contaminant-solid interactions. 2010 Elsevier B.V. All rights reserved.
Deployment of a Fast-GCMS System to Measure C2 to C5 Carbonyls, Methanol and Ethanol Aboard Aircraft
NASA Technical Reports Server (NTRS)
Apel, Eric C.
2004-01-01
Through funding of this proposal, a fast response gas chromatograph/mass spectrometer (FGCMS) instrument to measure less than or equal to C4 carbonyl compounds and methanol was developed for the NASA GTE TRACE-P (Global Tropospheric Experiment, Transport And Chemical Evolution Over The Pacific) mission. The system consists of four major components: sample inlet, preconcentration system, gas chromatograph (GC), and detector. The preconcentration system is a custom-built cryogen-conservative system. The GC is a compact, custom-built unit that can be temperature programmed and rapidly cooled. Detection is accomplished with an Agilent Technologies 5973 mass spectrometer. The FGCMS instrument provides positive identification because the compounds are chromatographically separated and mass selected. During TRACE-P, a sample was analyzed every 5 minutes. The FGCMS limit of detection was between 5 and 75 pptv, depending on the compound. The entire instrument package is contained in a standard NASA instrument rack (106 cm x 61 cm x 135 cm), consumes less than 1200 watts and is fully automated with LabViEW 6i. Methods were developed or producing highly accurate gas phase standards for the target compounds and for testing the system in the presence of potential interferents. This report presents data on these tests and on the general overall performance of the system in the laboratory and aboard the DC-8 aircraft during the mission. Vertical profiles for acetaldehyde, methanol, acetone, propanal, methyl ethyl ketone, and butanal from FGCMS data collected over the entire mission are also presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berkley, R.E.; Gardner, B.D.; Holland, J.F.
1997-12-31
A high-speed gas chromatograph coupled with a high-speed time-of-flight mass spectrometer was used to gain a six-fold increase in overall rate of analytical throughput for analysis of EPA Method TO-14 target compounds. Duration of chromatograms was 180 seconds. One hundred mass spectra per second, ranging from 35 to 270 mass units, were collected. Single ion chromatograms were searched at appropriate retention times for chromatographic peaks, which were integrated. Thirty-eight of the forty-one TO-14 target compounds were calibrated using standards at five concentrations from 2.5 to 40 ppb. Four grab samples of ambient air were collected at four different locations atmore » an automobile repair facility, and two grab samples were collected less than one minute apart at a site near a chemical plant, just before and just after passage of three large diesel trucks. All samples were analyzed on the same day they were collected. Most of the duplicate analyses were in close agreement. Ability of the high-speed TOF/GC/MS system to perform analyses of TO-14 target compounds rapidly and precisely was demonstrated. This paper has been reviewed according to US Environmental Protection Agency peer and administrative review policies and approved for presentation and publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use.« less
The role of off-line mass spectrometry in nuclear fission.
De Laeter, J R
1996-01-01
The role of mass spectrometry in nuclear fission has been invaluable since 1940, when A. O. C. Nier separated microgram quantities of (235) U from (238) U, using a gas source mass spectrometer. This experiment enabled the fissionable nature of (235) U to be established. During the Manhattan Project, the mass spectrometer was used to measure the isotope abundances of uranium after processing in various separation systems, in monitoring the composition of the gaseous products in the Oak Ridge Diffusion Plant, and as a helium leak detector. Following the construction of the first reactor at the University of Chicago, it was necessary to unravel the nuclear systematics of the various fission products produced in the fission process. Off-line mass spectrometry was able to identify stable and long-lived isotopes produced in fission, but more importantly, was used in numerous studies of the distribution of mass of the cumulative fission yields. Improvements in sensitivity enabled off-line mass spectrometric studies to identify fine structure in the mass-yield curve and, hence, demonstrate the importance of shell structure in nuclear fission. Solid-source mass spectrometry was also able to measure the cumulative fission yields in the valley of symmetry in the mass-yield curve, and enabled spontaneous fission yields to be quantified. Apart from the accurate measurement of abundances, the stable isotope mass spectrometric technique has been invaluable in establishing absolute cumulative fission yields for many isotopes making up the mass-yield distribution curve for a variety of fissile nuclides. Extensive mass spectrometric studies of noble gases in primitive meteorites revealed the presence of fission products from the now extinct nuclide (244) Pu, and have eliminated the possibility of fission products from a super-heavy nuclide contributing to isotopic anomalies in meteoritic material. Numerous mass spectrometric studies of the isotopic and elemental abundances of samples from the Oklo Natural Reactor have enabled the nuclear parameters of the various reactor zones to be calculated, and the mobility/retentivity of a number of elements to be established in the reactor zones and the surrounding rocks. These isotopic studies have given valuable information on the geochemical behavior of natural geological repositories for radioactive waste containment. © 1997 John Wiley & Sons, Inc. Copyright © 1997 John Wiley & Sons, Inc.
A Retrospective Evaluation of the Use of Mass Spectrometry in FDA Biologics License Applications
NASA Astrophysics Data System (ADS)
Rogstad, Sarah; Faustino, Anneliese; Ruth, Ashley; Keire, David; Boyne, Michael; Park, Jun
2017-05-01
The characterization sections of biologics license applications (BLAs) approved by the United States Food and Drug Administration (FDA) between 2000 and 2015 were investigated to examine the extent of the use of mass spectrometry. Mass spectrometry was found to be integral to the characterization of these biotherapeutics. Of the 80 electronically submitted monoclonal antibody and protein biotherapeutic BLAs included in this study, 79 were found to use mass spectrometric workflows for protein or impurity characterization. To further examine how MS is being used in successful BLAs, the applications were filtered based on the type and number of quality attributes characterized, the mass spectrometric workflows used (peptide mapping, intact mass analysis, and cleaved glycan analysis), the methods used to introduce the proteins into the gas phase (ESI, MALDI, or LC-ESI), and the specific types of instrumentation used. Analyses were conducted over a time course based on the FDA BLA approval to determine if any trends in utilization could be observed over time. Additionally, the different classes of protein-based biotherapeutics among the approved BLAs were clustered to determine if any trends could be attributed to the specific type of biotherapeutic.
Mazzarino, Monica; de la Torre, Xavier; Di Santo, Roberto; Fiacco, Ilaria; Rosi, Federica; Botrè, Francesco
2010-03-01
Different liquid chromatographic/tandem mass spectrometric (LC/MS/MS) scanning techniques were considered for the characterization of tamoxifene metabolites in human urine for anti-doping purpose. Five different LC/MS/MS scanning methods based on precursor ion scan (precursor ion scan of m/z 166, 152 and 129) and neutral loss scan (neutral loss of 72 Da and 58 Da) in positive ion mode were assessed to recognize common ions or common losses of tamoxifene metabolites. The applicability of these methods was checked first by infusion and then by the injection of solution of a mixture of reference standards of four tamoxifene metabolites available in our laboratory. The data obtained by the analyses of the mixture of the reference standards showed that the five methods used exhibited satisfactory results for all tamoxifene metabolites considered at a concentration level of 100 ng/mL, whereas the analysis of blank urine samples spiked with the same tamoxifene metabolites at the same concentration showed that the neutral loss scan of 58 Da lacked sufficient specificity and sensitivity. The limit of detection in urine of the compounds studied was in the concentration range 10-100 ng/mL, depending on the compound structure and on the selected product ion. The suitability of these approaches was checked by the analysis of urine samples collected after the administration of a single dose of 20 mg of tamoxifene. Six metabolites were detected: 4-hydroxytamoxifene, 3,4-dihydroxytamoxifene, 3-hydroxy-4-methoxytamoxifene, N-demethyl-4-hydroxytamoxifene, tamoxifene-N-oxide and N-demethyl-3-hydroxy-4-methoxytamoxifene, which is in conformity to our previous work using a time-of-flight (TOF) mass spectrometer in full scan acquisition mode. Copyright (c) 2010 John Wiley & Sons, Ltd.
2011-09-01
of interest. Lack of bias with GC-MS method ........................................................ 12 3.1.1 Data requirements...14 3.2.1 Data ...3.3.1 Data requirements ....................................................................................................... 15 3.3.2 Success
Zhao, Yang; Chen, Hui-Jun; Caritis, Steve; Venkataramanan, Raman
2016-02-01
A liquid chromatography-tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7-hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7-hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5-100 ng/mL for granisetron and 0.1-100 ng/mL for 7-hydroxy granisetron in human plasma samples, and 2-2000 ng/mL for granisetron and 2-1000 ng/mL for 7-hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was <10%. No significant matrix effects were observed for granisetron or 7-hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. Copyright © 2015 John Wiley & Sons, Ltd.
Surface acoustic wave nebulization facilitating lipid mass spectrometric analysis.
Yoon, Sung Hwan; Huang, Yue; Edgar, J Scott; Ting, Ying S; Heron, Scott R; Kao, Yuchieh; Li, Yanyan; Masselon, Christophe D; Ernst, Robert K; Goodlett, David R
2012-08-07
Surface acoustic wave nebulization (SAWN) is a novel method to transfer nonvolatile analytes directly from the aqueous phase to the gas phase for mass spectrometric analysis. The lower ion energetics of SAWN and its planar nature make it appealing for analytically challenging lipid samples. This challenge is a result of their amphipathic nature, labile nature, and tendency to form aggregates, which readily precipitate clogging capillaries used for electrospray ionization (ESI). Here, we report the use of SAWN to characterize the complex glycolipid, lipid A, which serves as the membrane anchor component of lipopolysaccharide (LPS) and has a pronounced tendency to clog nano-ESI capillaries. We also show that unlike ESI SAWN is capable of ionizing labile phospholipids without fragmentation. Lastly, we compare the ease of use of SAWN to the more conventional infusion-based ESI methods and demonstrate the ability to generate higher order tandem mass spectral data of lipid A for automated structure assignment using our previously reported hierarchical tandem mass spectrometry (HiTMS) algorithm. The ease of generating SAWN-MS(n) data combined with HiTMS interpretation offers the potential for high throughput lipid A structure analysis.
NASA Technical Reports Server (NTRS)
Wood, G. M., Jr.
1974-01-01
A mass spectrometric system for determining the characteristics of materials used in instrumental development and aerospace applications was developed. The desorption spectra of cesium that was ion-implanted into polycrystalline tungsten and the effects on the spectra of bombardment of the tungsten by low energy (70 eV) electrons were investigated. Work function changes were measured by the retarding potential diode method. Flash desorption characteristics were observed and gas-reaction mechanisms of the surface of heated metal filaments were studied. Desorption spectra were measured by linearly increasing the sample temperature at a selected rate, the temperature cycling being generated from a ramp-driven dc power supply, with the mass spectrometer tuned to a mass number of interest. Results of the study indicate an anomolous desorption mechanism following an electron bombardment of the sample surface. The enhanced spectra are a function of the post-bombardment time and energy and are suggestive of an increased concentration of cesium atoms, up to 10 or more angstroms below the surface.
Goud, D Raghavender; Pardasani, Deepak; Purohit, Ajay Kumar; Tak, Vijay; Dubey, Devendra Kumar
2015-07-07
Sulfur monochloride (S2Cl2) and sulfur dichloride (SCl2) are important precursors of the extremely toxic chemical warfare agent sulfur mustard and classified, respectively, into schedule 3.B.12 and 3.B.13 of the Chemical Weapons Convention (CWC). Hence, their detection and identification is of vital importance for verification of CWC. These chemicals are difficult to detect directly using chromatographic techniques as they decompose and do not elute. Until now, the use of gas chromatographic approaches to follow the derivatized sulfur chlorides is not reported in the literature. The electrophilic addition reaction of sulfur monochloride and sulfur dichloride toward 3-hexyne was explored for the development of a novel derivatization protocol, and the products were subjected to gas chromatography-mass spectrometric (GC-MS) analysis. Among various unsaturated reagents like alkenes and alkynes, symmetrical alkyne 3-hexyne was optimized to be the suitable derivatizing agent for these analytes. Acetonitrile was found to be the suitable solvent for the derivatization reaction. The sample preparation protocol for the identification of these analytes from hexane spiked with petrol matrix was also optimized. Liquid-liquid extraction followed by derivatization was employed for the identification of these analytes from petrol matrix. Under the established conditions, the detection and quantification limits are 2.6 μg/mL, 8.6 μg/mL for S2Cl2 and 2.3 μg/mL, 7.7 μg/mL for SCl2, respectively, in selected ion monitoring (SIM) mode. The calibration curve had a linear relationship with y = 0.022x - 0.331 and r(2) = 0.992 for the working range of 10 to 500 μg/mL for S2Cl2 and y = 0.007x - 0.064 and r(2) = 0.991 for the working range of 10 to 100 μg/mL for SCl2, respectively. The intraday RSDs were between 4.80 to 6.41%, 2.73 to 6.44% and interday RSDs were between 2.20 to 7.25% and 2.34 to 5.95% for S2Cl2 and SCl2, respectively.
Móricz, Ágnes M; Ott, Péter G; Morlock, Gertrud E
2018-03-30
The knowledge about the activity of polyacetylenes was extended by their new acetylcholinesterase inhibition and antibacterial activity against plant pathogenic bacteria. For this discovery, an utmost streamlined workflow, which we consider to be of high potential in the field of natural product or superfood search was developed. It demonstrates the combined power of biological, biochemical and chemical fingerprints. Bioactive components of tansy (Tanacetum vulgare L.) root extract were profiled and identified by high-performance thin-layer chromatography hyphenated with in situ effect-directed analysis, chemical derivatizations and high-resolution mass spectrometry (HPTLC-UV/Vis/FLD-EDA-HRMS). The effect-directed profiling was performed using four bacterial bioassays including two plant pathogens, an antioxidant assay and acetyl- and butyrylcholinesterase inhibitory assays. The chromatographic, spectral and powerful mass spectrometric study of zones that exerted substantial antibacterial and/or antioxidant and/or acetylcholinesterase inhibitory effects allowed these multi-potent zones to be identified as polyacetylenes. Five polyacetylene compounds were assigned to be 2-non-1-ene-3,5,7-triynyl-3-vinyl-oxirane, 2-(2,4-hexadiynylidene)-3,4-epoxy-1,6-dioxaspiro[4.5]decane, trans- and cis-2-(2,4-hexadiynylidene)-1,6-dioxaspiro[4.5]dec-3-ene and tetradeca-2,4,6-triine-8-en-12-one. This study clearly showed the advantage of the combined use of different ionization sources, i.e. electrospray ionization via an elution-head based interface and also the Direct Analysis in Real Time interface, for HRMS analysis of compounds from the same class with very similar chromatographic behavior and polarity. Copyright © 2018 Elsevier B.V. All rights reserved.
The importance of mass spectrometric dereplication in fungal secondary metabolite analysis
Nielsen, Kristian F.; Larsen, Thomas O.
2015-01-01
Having entered the Genomic Era, it is now evident that the biosynthetic potential of filamentous fungi is much larger than was thought even a decade ago. Fungi harbor many cryptic gene clusters encoding for the biosynthesis of polyketides, non-ribosomal peptides, and terpenoids – which can all undergo extensive modifications by tailoring enzymes – thus potentially providing a large array of products from a single pathway. Elucidating the full chemical profile of a fungal species is a challenging exercise, even with elemental composition provided by high-resolution mass spectrometry (HRMS) used in combination with chemical databases (e.g., AntiBase) to dereplicate known compounds. This has led to a continuous effort to improve chromatographic separation in conjunction with improvement in HRMS detection. Major improvements have also occurred with 2D chromatography, ion-mobility, MS/MS and MS3, stable isotope labeling feeding experiments, classic UV/Vis, and especially automated data-mining and metabolomics software approaches as the sheer amount of data generated is now the major challenge. This review will focus on the development and implementation of dereplication strategies and will highlight the importance of each stage of the process from sample preparation to chromatographic separation and finally toward both manual and more targeted methods for automated dereplication of fungal natural products using state-of-the art MS instrumentation. PMID:25741325
Milton, Martin J T; Wang, Jian
2003-01-01
A new isotope dilution mass spectrometry (IDMS) method for high-accuracy quantitative analysis of gases has been developed and validated by the analysis of standard mixtures of carbon dioxide in nitrogen. The method does not require certified isotopic reference materials and does not require direct measurements of the highly enriched spike. The relative uncertainty of the method is shown to be 0.2%. Reproduced with the permission of Her Majesty's Stationery Office. Copyright Crown copyright 2003.
Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe
NASA Technical Reports Server (NTRS)
Niemann, Hasso; Atreya, S.; Demick-Monelara, J.; Haberman, J.; Harpold, D.; Kasprzak, W.; Owen, T.; Raaen, E.; Way, S.
2006-01-01
The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of mlz from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact.
Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe
NASA Technical Reports Server (NTRS)
Niemann, H.; Atreya, S.; Demick-Montelara, J.; Haberman, J.; Harpold, D.; Kasprzak, W.; Owen, T.; Raaen, E.; Way, S.
2006-01-01
The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, methane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact.
Simmonds, Peter G.
1970-01-01
Pyrolysis-gas chromatography-mass spectrometric studies of two microorganisms, Micrococcus luteus and Bacillus subtilis var. niger, indicate that the majority of thermal fragments originate from the principal classes of bio-organic matter found in living systems such as protein and carbohydrate. Furthermore, there is a close qualitative similarity between the type of pyrolysis products found in microorganisms and the pyrolysates of other biological materials. Conversely, there is very little correlation between microbial pyrolysates and comparable pyrolysis studies of meteoritic and fossil organic matter. These observations will aid in the interpretation of a soil organic analysis experiment to be performed on the surface of Mars in 1975. The science payload of this landed mission will include a combined pyrolysis-gas chromatography-mass spectrometry instrument as well as several “direct biology experiments” which are designed to search for extraterrestrial life. PMID:16349890
Sulfur Isotopes in Gas-rich Impact-Melt Glasses in Shergottites
NASA Technical Reports Server (NTRS)
Rao, M. N.; Hoppe, P.; Sutton, S. R.; Nyquist, Laurence E.; Huth, J.
2010-01-01
Large impact melt glasses in some shergottites contain huge amounts of Martian atmospheric gases and they are known as gas-rich impact-melt (GRIM) glasses. By studying the neutron-induced isotopic deficits and excesses in Sm-149 and Sm-150 isotopes resulting from Sm-149 (n,gamma) 150Sm reaction and 80Kr excesses produced by Br-79 (n,gamma) Kr-80 reaction in the GRIM glasses using mass-spectrometric techniques, it was shown that these glasses in shergottites EET79001 and Shergotty contain regolith materials irradiated by a thermal neutron fluence of approx.10(exp 15) n/sq cm near Martian surface. Also, it was shown that these glasses contain varying amounts of sulfates and sulfides based on the release patterns of SO2 (sulfate) and H2S (sulfide) using stepwise-heating mass-spectrometric techniques. Furthermore, EMPA and FE-SEM studies in basaltic-shergottite GRIM glasses EET79001, LithB (,507& ,69), Shergotty (DBS I &II), Zagami (,992 & ,994) showed positive correlation between FeO and "SO3" (sulfide + sulfate), whereas those belonging to olivine-phyric shergottites EET79001, LithA (,506, & ,77) showed positive correlation between CaO/Al2O3 and "SO3".
Rüger, Christopher P; Schwemer, Theo; Sklorz, Martin; O'Connor, Peter B; Barrow, Mark P; Zimmermann, Ralf
2017-02-01
The analysis of petrochemical materials and particulate matter originating from combustion sources remains a challenging task for instrumental analytical techniques. A detailed chemical characterisation is essential for addressing health and environmental effects. Sophisticated instrumentation, such as mass spectrometry coupled with chromatographic separation, is capable of a comprehensive characterisation, but needs advanced data processing methods. In this study, we present an improved data processing routine for the mass chromatogram obtained from gas chromatography hyphenated to atmospheric pressure chemical ionisation and ultra high resolution mass spectrometry. The focus of the investigation was the primary combustion aerosol samples, i.e. particulate matter extracts, as well as the corresponding fossil fuels fed to the engine. We demonstrate that utilisation of the entire transient and chromatographic information results in advantages including minimisation of ionisation artefacts and a reliable peak assignment. A comprehensive comparison of the aerosol and the feed fuel was performed by applying intensity weighted average values, compound class distribution and principle component analysis. Certain differences between the aerosol generated with the two feed fuels, diesel fuel and heavy fuel oil, as well as between the aerosol and the feed were revealed. For the aerosol from heavy fuel oil, oxidised species from the CHN and CHS class precursors of the feed were predominant, whereas the CHO x class is predominant in the combustion aerosol from light fuel oil. Furthermore, the complexity of the aerosol increases significantly compared to the feed and incorporating a higher chemical space. Coupling of atmospheric pressure chemical ionisation to gas chromatography was found to be a useful additional approach for characterisation of a combustion aerosol, especially with an automated utilisation of the information from the ultra-high resolution mass spectrometer and the chromatographic separation.
Outgassing of Flown and Unflown MIR Solar Cells
NASA Technical Reports Server (NTRS)
Harvey, Gale A.; Kinard, William H.; Wilson, Linda A.
2000-01-01
A solar panel array with more than ten years space exposure was removed from the Mir core module in November 1997, and an eight panel section was returned to Earth in January 1998. Several solar cells were removed from panel eight of the returned array and placed in a high vacuum system with a residual gas analyzer (200 amu mass spectrometer) and a cold finger. Similar unflown solar cells of the same vintage were later obtained from Energia. Several of the unflown cells were also placed in the vacuum system and outgassed residues were collected on the LN2 cold finger. Almost 3 mg of outgassed residue was collected -from a string of three unflown solar cells over a period of 94 hours under vacuum. The collected residue was weighed with a microbalance, and then the residue was analyzed by FTIR spectroscopy, and by gas chromatograph-mass spectroscopy. About 25 outgassed constituents were separated by the gas chromatograph, and a high-resolution mass spectrum was obtained of each constituent. Molecular identifications have been made for the constituents. The constituents are primarily cyclic siloxanes, and several of the constituents are isomers of the same molecule. Most of the outgassed constituents have a molecular mass of about 500 amu. Almost one mg of residue was extracted from one sq cm of coverglass/adhesive from a flown solar cell by soaking in isopropyl alcohol for 30 minutes. The gas chromatograph separated about 20 constituents. The constituents are mostly cyclic siloxanes with linear branches, hydrocarbons, and phthalates. The typical molecular mass is about 600 amu. These identifications of specific outgassing molecules have resulted in a more complete understanding of the SiO(x) contamination on the Mir solar cell coverglasses, and on the MEEP experiment trays and optical specimens during the Shuttle-Mir Phase One flight experiment program. Adjusted outgassing rates based on the data reported here, and/or measured outgassing rates and specific molecular identifications of ISS hardware samples are needed to input into model predictions of induced environment effects of the ISS.
Ifa, D R; Moraes, M E; Moraes, M O; Santagada, V; Caliendo, G; de Nucci, G
2000-03-01
A liquid chromatographic atmospheric pressure chemical ionization tandem mass spectrometric method is described for the determination of 21-hydroxydeflazacort in human plasma using dexamethasone 21-acetate as an internal standard. The procedure requires a single diethyl ether extraction. After evaporation of the solvent under a nitrogen flow, the analytes are reconstituted in the mobile phase, chromatographed on a C18 reversed-phase column and analyzed by mass spectrometry via a heated nebulizer interface where they are detected by multiple reaction monitoring. The method has a chromatographic run time of less than 5 min and a linear calibration curve with a range of 1-400 ng ml(-1) (r>0.999). The between-run precision, based on the relative standard deviation for replicate quality controls, was < or =5.5% (10 ng ml(-1)), 1.0% (50 ng ml(-1)) and 2.7% (200 ng ml(-1)). The between-run accuracy was +/-7.1, 3.8 and 4.8% for the above concentrations, respectively. This method was employed in a bioequivalence study of two DFZ tablet formulations (Denacen from Marjan Industria e Comercio, Brazil, as a test formulation, and Calcort from Merrell Lepetit, Brazil, as a reference formulation) in 24 healthy volunteers of both sexes who received a single 30 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 7-day washout interval. The 90% confidence interval (CI) of the individual geometric mean ratio for Denacen/Calcort was 89.8-109.5% for area under the curve AUC(0-24 h) and 80.7-98.5% for Cmax. Since both the 90% CI for AUC(0-24 h) and Cmax were included in the 80-125% interval proposed by the US Food and Drug Administration, Denacen was considered bioequivalent to Calcort according to both the rate and extent of absorption.
Development of an effusive inlet for mass spectrometric gas analysis of hypersonic boundary layer
NASA Technical Reports Server (NTRS)
Brown, Kenneth G.; Fishel, Charles E.; Brown, David R.; Lewis, Beverley W.; Wood, George M., Jr.
1987-01-01
The use of a microchannel plate (MCP) as a mass spectrometer inlet device to allow nonintrusive sampling of flight vehicle boundary layers is investigated. Two possible configurations for mounting the inlet are studied: (1) flow coaxial with the channels; and (2) flow perpendicular to the channel axis. The test gases are pure Kr; pure Ne; and a mixture of 10 pct Kr, 10 pct Ne, and 80 pct N2. The pressure ranges studied vary from 500 to 10 microns. A mass discrimination at the quadrupole mass spectrometer is observed, indicating an enrichment in the heavier gas. Possible explanations for this enrichment are discussed. It is shown that an MCP is capable of acting as a nonintrusive sampling device. Further work that will enable quantitative determination of the species at the surface is discussed.
A mass-balanced definition of corrected retention volume in gas chromatography.
Kurganov, A
2007-05-25
The mass balance equation of a chromatographic system using a compressible moving phase has been compiled for mass flow of the mobile phase instead of traditional volumetric flow allowing solution of the equation in an analytical form. The relation obtained correlates retention volume measured under ambient conditions with the partition coefficient of the solute. Compared to the relation in the ideal chromatographic system the equation derived contains an additional correction term accounting for the compressibility of the moving phase. When the retention volume is measured under the mean column pressure and column temperature the correction term is reduced to unit and the relation is simplified to those known for the ideal system. This volume according to International Union of Pure and Applied Chemistry (IUPAC) is called the corrected retention volume.
NASA Astrophysics Data System (ADS)
Ivanova, Bojidarka; Spiteller, Michael
2013-02-01
The paper presented a comprehensive theoretical and experimental study on the molecular drugs-design, synthesis, isolation, physical spectroscopic and mass spectrometric elucidation of novel functionalization derivatives of Cytisine (Cyt), using nucleosidic residues. Since these alkaloids have established biochemical profile, related the binding affinity of the nicotinic acetylcholine receptors (nAChRs), particularly α7 sub-type, the presented correlation between the molecular structure and properties allowed to evaluated the highlights of the biochemical hypothesises related the Schizophrenia. The anticancer activity of α7 subtype agonists and the crucial role of the nucleoside-based medications in the cancer therapy provided opportunity for further study on the biochemical relationship between Schizophrenia and few kinds of cancers, which has been hypothesized recently. The physical electronic absorptions (EAs), circular dichroic (CD) and Raman spectroscopic (RS) properties as well as mass spectrometric (MS) data, obtained using electrospray ionization (ESI) and atmospheric-pressure chemical ionization (APCI) methods under the positive single (MS) and tandem (MS/MS) modes of operation are discussed. Taking into account reports on a fatal intoxication of Cyt, the presented data would be of interest in the field of forensic chemistry, through development of highly selective and sensitive analytical protocols. Quantum chemical method is used to predict the physical properties of the isolated alkaloids, their affinity to the receptor loop and gas-phase stabilized species, observed mass spectrometrically.
Apparatus for focusing flowing gas streams
Nogar, N.S.; Keller, R.A.
1985-05-20
Apparatus for focusing gas streams. The principle of hydrodynamic focusing is applied to flowing gas streams in order to provide sample concentration for improved photon and sample utilization in resonance ionization mass spectrometric analysis. In a concentric nozzle system, gas samples introduced from the inner nozzle into the converging section of the outer nozzle are focused to streams 50-250-..mu..m in diameter. In some cases diameters of approximately 100-..mu..m are maintained over distances of several centimeters downstream from the exit orifice of the outer nozzle. The sheath gas employed has been observed to further provide a protective covering around the flowing gas sample, thereby isolating the flowing gas sample from possible unwanted reactions with nearby surfaces. A single nozzle variation of the apparatus for achieving hydrodynamic focusing of gas samples is also described.
Lee, Byeong Ill; Park, Min-Ho; Heo, Soon Chul; Park, Yuri; Shin, Seok-Ho; Byeon, Jin-Ju; Kim, Jae Ho; Shin, Young G
2018-03-01
A liquid chromatographic-electrospray ionization-time-of-flight/mass spectrometric (LC-ESI-TOF/MS) method was developed and applied for the determination of WKYMVm peptide in rat plasma to support preclinical pharmacokinetics studies. The method consisted of micro-elution solid-phase extraction (SPE) for sample preparation and LC-ESI-TOF/MS in the positive ion mode for analysis. Phenanthroline (10 mg/mL) was added to rat blood immediately for plasma preparation followed by addition of trace amount of 2 m hydrogen chloride to plasma before SPE for stability of WKYMVm peptide. Then sample preparation using micro-elution SPE was performed with verapamil as an internal standard. A quadratic regression (weighted 1/concentration 2 ), with the equation y = ax 2 + bx + c was used to fit calibration curves over the concentration range of 3.02-2200 ng/mL for WKYMVm peptide. The quantification run met the acceptance criteria of ±25% accuracy and precision values. For quality control samples at 15, 165 and 1820 ng/mL from the quantification experiment, the within-run and the between-run accuracy ranged from 92.5 to 123.4% with precision values ≤15.1% for WKYMVm peptide from the nominal values. This novel LC-ESI-TOF/MS method was successfully applied to evaluate the pharmacokinetics of WKYMVm peptide in rat plasma. Copyright © 2017 John Wiley & Sons, Ltd.
Qin, Yuhong; Zhang, Jingru; Zhang, Yuan; Li, Fangbing; Han, Yongtao; Zou, Nan; Xu, Haowei; Qian, Meiyuan; Pan, Canping
2016-09-02
An automated multi-plug filtration cleanup (m-PFC) method on modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts was developed. The automatic device was aimed to reduce labor-consuming manual operation workload in the cleanup steps. It could control the volume and the speed of pulling and pushing cycles accurately. In this work, m-PFC was based on multi-walled carbon nanotubes (MWCNTs) mixed with other sorbents and anhydrous magnesium sulfate (MgSO4) in a packed tip for analysis of pesticide multi-residues in crop commodities followed by liquid chromatography with tandem mass spectrometric (LC-MS/MS) detection. It was validated by analyzing 25 pesticides in six representative matrices spiked at two concentration levels of 10 and 100μg/kg. Salts, sorbents, m-PFC procedure, automated pulling and pushing volume, automated pulling speed, and pushing speed for each matrix were optimized. After optimization, two general automated m-PFC methods were introduced to relatively simple (apple, citrus fruit, peanut) and relatively complex (spinach, leek, green tea) matrices. Spike recoveries were within 83 and 108% and 1-14% RSD for most analytes in the tested matrices. Matrix-matched calibrations were performed with the coefficients of determination >0.997 between concentration levels of 10 and 1000μg/kg. The developed method was successfully applied to the determination of pesticide residues in market samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Carlier, Mieke; Stove, Veronique; Roberts, Jason A; Van de Velde, Eric; De Waele, Jan J; Verstraete, Alain G
2012-11-01
There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a rapid ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, ampicillin, cefuroxime, cefazolin, ceftazidime, meropenem, piperacillin, clavulanic acid and tazobactam. Sample clean-up included protein precipitation with acetonitrile and back-extraction of acetonitrile with dichloromethane. Six deuterated β-lactam antibiotics were used as internal standards. Chromatographic separation was performed on a Waters ACQUITY UPLC system using a BEH C(18) column (1.7 μm, 100 mm×2.1 mm) applying a binary gradient elution of water and acetonitrile both containing 0.1% formic acid. The total run time was 5.5 min. The developed method was validated in terms of precision, accuracy, linearity, matrix effect and recovery. The assay has now been successfully used to determine concentrations of amoxicillin/clavulanic acid, cefuroxime and meropenem in plasma samples from intensive care patients. Copyright © 2012 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
HIGH SPEED GC/MS FOR AIR ANALYSIS
A high speed GC/MS system consisting of a gas chromatograph equipped with a narrow bandwidth injection accessory and using a time-of-flight mass spectrometer detector has been adapted for analysis of ambient whole air samples which have been collected in passivated canisters. ...
ANALYSIS OF VOLATILES AND SEMIVOLATILES BY DIRECT AQUEOUS INJECTION
Direct aqueous injection analysis (DAI) with gas chromatographic separation and ion trap mass spectral detection was used to analyze aqueous samples for g/L levels of 54 volatile and semivolatile compounds, and problematic non-purgeables and non-extractables. The method reduces ...
Innovative Technology Development for Comprehensive Air Quality Characterization from Open Burning
2012-04-01
Burning/Open Detonation (OB/OD) has been used as a safe, effective , and economic way to demilitarize munitions for energetic material disposal. Field...target analyte i (lb/lb i in ordnance) ERDC-CERL Engineer Research Development Center, Construction Engineering Research Laboratory GC/FID gas ...chromatograph(y) - flame ionization detector GC/MS gas chromatography/mass spectrometry GPS global positioning system ISO International Organization for
Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick
2015-01-01
This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.
Van den Meersche, Tina; Van Pamel, Els; Van Poucke, Christof; Herman, Lieve; Heyndrickx, Marc; Rasschaert, Geertrui; Daeseleire, Els
2016-01-15
In this study, a fast, simple and selective ultra high performance liquid chromatographic-tandem mass spectrometric (UHPLC-MS/MS) method for the simultaneous detection and quantification of colistin, sulfadiazine, trimethoprim, doxycycline, oxytetracycline and ceftiofur and for the detection of tylosin A in swine manure was developed and validated. First, a simple extraction procedure with acetonitrile and 6% trichloroacetic acid was carried out. Second, the supernatant was evaporated and the pellet was reconstituted in 1 ml of water/acetonitrile (80/20) and 0.1% formic acid. Extracts were filtered and analyzed by UHPLC-MS/MS on a Kinetex C18 column using gradient elution. The method developed was validated according to the criteria of Commission Decision 2002/657/EC. Recovery percentages varied between 94% and 106%, repeatability percentages were within the range of 1.7-9.2% and the intralaboratory reproducibility varied between 2.8% and 9.3% for all compounds, except for tylosin A for which more variation was observed resulting in a higher measurement uncertainty. The limit of detection and limit of quantification varied between 1.1 and 20.2 and between 3.5 and 67.3 μg/kg, respectively. This method was used to determine the presence and concentration of the seven antibiotic residues in swine manure sampled from ten different manure pits on farms where the selected antibiotics were used. A link was found between the antibiotics used and detected, except for ceftiofur which is injected at low doses and degraded readily in swine manure and was therefore not recovered in any of the samples. To the best of our knowledge, this is the first method available for the simultaneous extraction and quantification of colistin with other antibiotic classes. Additionally, colistin was never extracted from swine manure before. Another innovative aspect of this method is the simultaneous detection and quantification of five different classes of antibiotic residues in swine manure. Copyright © 2015 Elsevier B.V. All rights reserved.
Cooke, Darren N; Thomasset, Sarah; Boocock, David J; Schwarz, Michael; Winterhalter, Peter; Steward, William P; Gescher, Andreas J; Marczylo, Timothy H
2006-09-20
Anthocyanins are potent antioxidants that may possess chronic disease preventive properties. Here, rapid, reliable, and reproducible solid-phase extraction, high-performance liquid chromatography (HPLC), and mass spectrometry techniques are described for the isolation, separation, and identification of anthocyanins in human plasma and urine. Recoveries of cyanidin-3-glucoside (C3G) were 91% from water, 71% from plasma, and 81% from urine. Intra- and interday variations for C3G extraction were 9 and 9.1% in plasma and 7.1 and 9.1% in urine and were less than 15% for all anthocyanins from a standardized bilberry extract (mirtoselect). Analysis of mirtoselect by HPLC with UV detection produced spectra with 15 peaks compatible with anthocyanin components found in mirtoselect within a total run time of 15 min. Chromatographic analysis of human urine obtained after an oral dose of mirtoselect yielded 19 anthocyanin peaks. Mass spectrometric analysis employing multiple reaction monitoring suggests the presence of unchanged anthocyanins and anthocyanidin glucuronide metabolites.
Swider, Catherine; Maguire, Kelly; Rickenbach, Michael; Montgomery, Madeline; Ducote, Matthew J; Marhefka, Craig A
2012-07-01
Following the September 11, 2001 terrorist attacks, letters containing Bacillus anthracis were distributed through the United States postal system killing five people. A complex forensic investigation commenced to identify the perpetrator of these mailings. A novel liquid chromatography/mass spectrometry protocol for the qualitative detection of trace levels of meglumine and diatrizoate in dried spore preparations of B. anthracis was developed. Meglumine and diatrizoate are components of radiographic imaging products that have been used to purify bacterial spores. Two separate chromatographic assays using multiple mass spectrometric analyses were developed for the detection of meglumine and diatrizoate. The assays achieved limits of detection for meglumine and diatrizoate of 1.00 and 10.0 ng/mL, respectively. Bacillus cereus T strain spores were effectively used as a surrogate for B. anthracis spores during method development and validation. This protocol was successfully applied to limited evidentiary B. anthracis spore material, providing probative information to the investigators. 2012 American Academy of Forensic Sciences. Published 2012. This article is a U.S. Government work and is in the public domain in the U.S.A.
Analytical surveillance of emerging drugs of abuse and drug formulations
Thomas, Brian F.; Pollard, Gerald T.; Grabenauer, Megan
2012-01-01
Uncontrolled recreational drugs are proliferating in number and variety. Effects of long-term use are unknown, and regulation is problematic, as efforts to control one chemical often lead to several other structural analogs. Advanced analytical instrumentation and methods are continuing to be developed to identify drugs, chemical constituents of products, and drug substances and metabolites in biological fluids. Several mass spectrometry based approaches appear promising, particularly those that involve high resolution chromatographic and mass spectrometric methods that allow unbiased data acquisition and sophisticated data interrogation. Several of these techniques are shown to facilitate both targeted and broad spectrum analysis, which is often of particular benefit when dealing with misleadingly labeled products or assessing a biological matrix for illicit drugs and metabolites. The development and application of novel analytical approaches such as these will help to assess the nature and degree of exposure and risk and, where necessary, inform forensics and facilitate implementation of specific regulation and control measures. PMID:23154240
Nakamura, Tatsuji; Kuromitsu, Junro; Oda, Yoshiya
2008-03-01
Two-dimensional liquid-chromatographic (LC) separation followed by mass spectrometric (MS) analysis was examined for the identification of peptides in complex mixtures as an alternative to widely used two-dimensional gel electrophoresis followed by MS analysis for use in proteomics. The present method involves the off-line coupling of a narrow-bore, polymer-based, reversed-phase column using an acetonitrile gradient in an alkaline mobile phase in the first dimension with octadecylsilanized silica (ODS)-based nano-LC/MS in the second dimension. After the first separation, successive fractions were acidified and dried off-line, then loaded on the second dimension column. Both columns separate peptides according to hydrophobicity under different pH conditions, but more peptides were identified than with the conventional technique for shotgun proteomics, that is, the combination of a strong cation exchange column with an ODS column, and the system was robust because no salts were included in the mobile phases. The suitability of the method for proteomics measurements was evaluated.
Gas permeation measurements on small polymer specimens
NASA Technical Reports Server (NTRS)
Burns, Karen S.; Vannorman, John D.
1988-01-01
Mass spectrometry was used to measure oxygen and nitrogen permeabilities while polarography was used to measure oxygen permeabilities for several contact lens materials. Applicable sample holders were designed and fabricated to accommodate curved and flat specimens. A prepared standard was used to calibrate the mass spectrometric analyses. The oxygen permeability values determined by mass spectrometry were significantly greater than those determined by polarography. This was attributed to the phase boundary phenomena and the limiting oxygen permeance of water inherent in the polarographic technique. Polarographic values determined were in good agreement with proprietary values obtained by polarography, with the exception of one material.
1991-05-10
Hall, D . Mikrochim. Acta 1987, 1, 275. 26. Harrison, W.W.; Bentz , B.L. Prog. Analyt. Spectrosc. 1988, L19 53. 27. Harrison, W.W.; Barshick, C.M...Innovation, and Applications. ACS Symp. Series; Buchanan, M.V., Ed.; American Chemical Society: Washington, 1987; 359, p 1. 3. Wilkins, C.L.; Chowdhury, A.K...J.L. In Gas Phase Ion CheMistry; Bowers, M.T., Ed.; Academic: New York, 1984; Vol. 3, p 41. 6. Dunbar, R.C. In Gas Phase Ion Chemistry; Bowvers, M.T
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Feng; Cooper, S.F.
A novel gas chromatography-mass spectrometric (GC-MS) method was developed to confirm and identify metoprolol and its metabolites by double derivatization with S-(-)menthyl chloroformate [(-)-MCF] and N-methyl(trimethylsilyl-trifluoroacetamide) (MSTFA). This is the first report, which describes the simultaneous identification of metoprolol, its one major acidc and other basic metabolites in human urine based on solid-phase extraction with C{sub 18} reversed-phase cartridges. 12 refs., 4 figs.
40 CFR 1065.267 - Gas chromatograph.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Gas chromatograph. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon Measurements § 1065.267 Gas chromatograph...
40 CFR 1065.267 - Gas chromatograph.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Gas chromatograph. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon Measurements § 1065.267 Gas chromatograph...
NASA Astrophysics Data System (ADS)
Elkins, J. W.; Moore, F. L.; Hintsa, E. J.; Dutton, G. S.; Nance, J. D.; Hall, B. D.
2016-12-01
NOAA scientists started in situ airborne measurements of two strong ozone-depleting gases or chlorofluorocarbons, CFC-11 and CFC-113 in 1991 on the NASA ER-2 aircraft with a two-channel gas chromatograph, Airborne Chromatograph for Atmospheric Trace Species (ACATS). We broaden our list of gases to include more ozone-depleting and other climate-related gases. An improved 4-channel gas chromatograph that included N2O, SF6, CFC-11, -12, -113, halon-1211, CCl4, CH3CCl3, CH4, CO, and H2 was added to the ER-2 aircraft in 1994. As CFC replacements took hold, we add a gas chromatograph-mass spectrometer system, PAN and other Trace Hydro-halocarbon Experiment (PANTHER), to examine shorter-lived gases mainly in the upper troposphere. These airborne measurements were to complement of ground-based flask and in situ measurements from the NOAA Halocarbon and other Trace Species Network. This talk will show results from a tropical study, Airborne Tropical Tropopause Experiment (ATTREX) on the NASA Global Hawk aircraft and preliminary results from the Atmospheric Tomography Mission (ATom) conducted in August 2016 on the NASA DC-8 aircraft. A detrended, gridded, latitudinal distribution of SF6 is shown in the figure below for the years of 1994 through 2014. Such a plot may be useful to atmospheric modelers trying to capture transport or calculate emissions.
Duncan, M W; Smythe, G A; Clezy, P S
1985-03-01
Synthesis of deuterated (2H4)salsolinol from (2H4)dopamine via a Pictet-Spengler condensation is described. This (2H4)salsolinol is an ideal internal standard to determine picomole (ng) amounts of salsolinol (SAL) in a variety of sample types including urine, plasma, beverages and fruits. The deuterated standard is completely free of contamination by the non-deuterated species. The extraction procedure described is fast, highly efficient and does not lead to artifactual salsolinol formation even in the face of high dopamine concentrations. As well as SAL the method described allows simultaneous determination of norepinephrine (NE), dopamine (DA) and its two metabolites dihydroxyphenylacetic acid (DOPAC) and dihydroxyphenylethanol (DOPET). Each of the analytes is measured as its trifluoroacetyl derivative. Using trifluoroacetic anhydride in conjunction with trifluoroethanol allows simultaneous one-step derivatization of the acid function of DOPAC. All compounds were measured in the single ion monitoring (SIM) mode and quantified using appropriate deuterated internal standards. SAL, DA, DOPET, DOPAC and NE have been quantified in a variety of food and beverage sources. Soy sauce and dried banana have been identified as rich dietary sources of SAL. These data suggest diet should be considered a potentially important source of 'mammalian alkaloids' such as SAL, and the presence of SAL in mammalian systems is not necessarily evidence for an in vivo Pictet-Spengler condensation.
SLC2A8 (GLUT8) is a mammalian trehalose transporter required for trehalose-induced autophagy.
Mayer, Allyson L; Higgins, Cassandra B; Heitmeier, Monique R; Kraft, Thomas E; Qian, Xia; Crowley, Jan R; Hyrc, Krzysztof L; Beatty, Wandy L; Yarasheski, Kevin E; Hruz, Paul W; DeBosch, Brian J
2016-12-06
Trehalose is a disaccharide demonstrated to mitigate disease burden in multiple murine neurodegenerative models. We recently revealed that trehalose rapidly induces hepatic autophagy and abrogates hepatic steatosis by inhibiting hexose transport via the SLC2A family of facilitative transporters. Prior studies, however, postulate that intracellular trehalose is sufficient to induce cellular autophagy. The objective of the current study was to identify the means by which trehalose accesses the hepatocyte cytoplasm, and define the distal signaling mechanisms by which trehalose induces autophagy. We provide gas chromatographic/mass spectrometric, fluorescence microscopic and radiolabeled uptake evidence that trehalose traverses the plasma membrane via SLC2A8 (GLUT8), a homolog of the trehalose transporter-1 (Tret1). Moreover, GLUT8-deficient hepatocytes and GLUT8-deficient mice exposed to trehalose resisted trehalose-induced AMP-activated protein kinase (AMPK) phosphorylation and autophagic induction in vitro and in vivo. Although trehalose profoundly attenuated mTORC1 signaling, trehalose-induced mTORC1 suppression was insufficient to activate autophagy in the absence of AMPK or GLUT8. Strikingly, transient, heterologous Tret1 overexpression reconstituted autophagic flux and AMPK signaling defects in GLUT8-deficient hepatocyte cultures. Together, these data suggest that cytoplasmic trehalose access is carrier-mediated, and that GLUT8 is a mammalian trehalose transporter required for hepatocyte trehalose-induced autophagy and signal transduction.
A new insight into the particulate iodine in the marine boundary layer
NASA Astrophysics Data System (ADS)
Huang, R.-J.; Thorenz, U. R.; Kundel, M.; Kampf, C.; Vogel, A.; Ceburnis, D.; O'Dowd, C. D.
2012-04-01
Especially within the last few years the role of iodine in the lower troposphere has received increasing attention. In addition to the potential to affect the atmospheric oxidation capacity in a variety of ways such as catalytic destruction of ozone, the importance of iodine in the natural new particle formation (via secondary gas-to-particle conversion) in the marine boundary layer (MBL) is responsible for the increased interest and is motivated by the role of marine aerosol particles in the global radiation budget. One goal of current research activities is the identification and quantification of natural particle formation processes in the MBL. Although some progress has been made in recent years, the chemical species, reaction cycling and evolution of particulate iodine are still poorly understood, which in turn hinders our knowledge of the marine new particle formation processes. Here we will present results from recent field campaigns carried out at the Mace Head Atmospheric Research Station on the west coast of Ireland. The speciation of particulate iodine is performed by a newly developed precolumn derivatization and solid phase extraction preseparation method in combination with liquid chromatographic/mass spectrometric determination. The diurnal and seasonal variation as well as the cycling of different iodine species in the marine aerosols will be discussed. Furthermore, the linkage between gaseous reactive iodine species and particulate iodine will be presented.
Zancada, M Cristina; Almendros, Gonzalo; Sanz, Jesús; Román, Román
2004-02-01
The progressive transformations of lipid and humus-like fractions in soil after massive input (400 Mg ha(-1)) of urban waste have been studied during an 87-week experiment in field plots of a degraded Calcic Regosol in Central Spain. Structural changes in the macromolecular fractions were small when compared with the qualitative and quantitative changes in lipid composition. The intense depletion of the lipid fraction with time and the decrease of the humic acid to fulvic acid ratio were the most significant quantitative indices of the compost transformation in soil. Changes in soil lipid fractions were especially noted in relation to their speciation status and distribution patterns (carbon preference index and relative chain length). Three subfractions were considered: (I) direct extraction with petroleum ether, (II) liquid-liquid extraction after soil treatment with 2 M H3PO4 and (III) after soil treatment with 0.1 M NaOH. Although lipid concentration tends to decrease with time, lipids in the fraction tightly bonded to soil (III) remained qualitatively and quantitatively constant in the course of the field experiment. Gas chromatographic-mass spectrometric analyses showed that the more stable the association of lipid to the soil matrix, the fewer the changes observed in the distribution pattern of the fatty acids during the progressive transformation stages.
Biochemical analysis of 'kerosene tree' Hymenaea courbaril L. under heat stress.
Gupta, Dinesh; Eldakak, Moustafa; Rohila, Jai S; Basu, Chhandak
2014-01-01
Hymenaea courbaril or jatoba is a tropical tree known for its medically important secondary metabolites production. Considering climate change, the goal of this study was to investigate differential expression of proteins and lipids produced by this tree under heat stress conditions. Total lipid was extracted from heat stressed plant leaves and various sesquiterpenes produced by the tree under heat stress were identified. Gas chromatographic and mass spectrometric analysis were used to study lipid and volatile compounds produced by the plant. Several volatiles, isoprene, 2-methyl butanenitrile, β ocimene and a numbers of sesquiterpenes differentially produced by the plant under heat stress were identified. We propose these compounds were produced by the tree to cope up with heat stress. A protein gel electrophoresis (2-D DIGE) was performed to study differential expression of proteins in heat stressed plants. Several proteins were found to be expressed many folds different in heat stressed plants compared to the control. These proteins included heat shock proteins, histone proteins, oxygen evolving complex, and photosynthetic proteins, which, we believe, played key roles in imparting thermotolerance in Hymenaea tree. To the best of our knowledge, this is the first report of extensive molecular physiological study of Hymenaea trees under heat stress. This work will open avenues of further research on effects of heat stress in Hymenaea and the findings can be applied to understand how global warming can affect physiology of other plants.
Nandrolone: a multi-faceted doping agent.
Hemmersbach, Peter; Grosse, Joachim
2010-01-01
Nandrolone or nortestosterone, an anabolic-androgenic steroid, has been prohibited by doping control regulations for more than 30 years. Although its main metabolism in the human body was already known at that time, and detection of its misuse by gas or liquid chromatographic separation with mass spectrometric detection is straightforward, many interesting aspects regarding this doping agent have appeared since.Over the years, nandrolone preparations have kept their position among the prohibited substances that are most frequently detected in WADA-accredited laboratories. Their forms of application range from injectable fatty acid esters to orally administered nandrolone prohormones. The long detection window for nandrolone ester preparations and the appearance of orally available nandrolone precursors have changed the pattern of misuse.At the same time, more refined analytical methods with lowered detection limits led to new insights into the pharmacology of nandrolone and revelation of its natural production in the body.Possible contamination of nutritional supplements with nandrolone precursors, interference of nandrolone metabolism by other drugs and rarely occurring critical changes during storage of urine samples have to be taken into consideration when interpreting an analytical finding.A set of strict identification criteria, including a threshold limit, is applied to judge correctly an analytical finding of nandrolone metabolites. The possible influence of interfering drugs, urine storage or natural production is taken into account by applying appropriate rules and regulations.
Application of Laser Mass Spectrometry to Art and Archaeology
NASA Technical Reports Server (NTRS)
Gulian, Lase Lisa E.; Callahan, Michael P.; Muliadi, Sarah; Owens, Shawn; McGovern, Patrick E.; Schmidt, Catherine M.; Trentelman, Karen A.; deVries, Mattanjah S.
2011-01-01
REMPI laser mass spectrometry is a combination of resonance enhanced multiphoton ionization spectroscopy and time of flight mass spectrometry, This technique enables the collection of mass specific optical spectra as well as of optically selected mass spectra. Analytes are jet-cooled by entrainment in a molecular beam, and this low temperature gas phase analysis has the benefit of excellent vibronic resolution. Utilizing this method, mass spectrometric analysis of historically relevant samples can be simplified and improved; Optical selection of targets eliminates the need for chromatography while knowledge of a target's gas phase spectroscopy allows for facile differentiation of molecules that are in the aqueous phase considered spectroscopically indistinguishable. These two factors allow smaller sample sizes than commercial MS instruments, which in turn will require less damage to objects of antiquity. We have explored methods to optimize REMPI laser mass spectrometry as an analytical tool to archaeology using theobromine and caffeine as molecular markers in Mesoamerican pottery, and are expanding this approach to the field of art to examine laccaic acid in shellacs.
Pramann, Axel; Rienitz, Olaf
2016-06-07
A new generation of silicon crystals even further enriched in (28)Si (x((28)Si) > 0.999 98 mol/mol), recently produced by companies and institutes in Russia within the framework of a project initiated by PTB, were investigated with respect to their isotopic composition and molar mass M(Si). A modified isotope dilution mass spectrometric (IDMS) method treating the silicon as the matrix containing a so-called virtual element (VE) existing of the isotopes (29)Si and (30)Si solely and high resolution multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) were applied in combination. This method succeeds also when examining the new materials holding merely trace amounts of (29)Si (x((29)Si) ≈ 5 × 10(-6) mol/mol) and (30)Si (x((30)Si) ≈ 7 × 10(-7) mol/mol) extremely difficult to detect with lowest uncertainty. However, there is a need for validating the enrichment in (28)Si already in the precursor material of the final crystals, silicon tetrafluoride (SiF4) gas prior to crystal production. For that purpose, the isotopic composition of selected SiF4 samples was determined using a multicollector magnetic sector field gas-phase isotope ratio mass spectrometer. Contaminations of SiF4 by natural silicon due to storing and during the isotope ratio mass spectrometry (IRMS) measurements were observed and quantified. The respective MC-ICP-MS measurements of the corresponding crystal samples show-in contrast-several advantages compared to gas phase IRMS. M(Si) of the new crystals were determined to some extent with uncertainties urel(M) < 1 × 10(-9). This study presents a clear dependence of the uncertainty urel(M(Si)) on the degree of enrichment in (28)Si. This leads to a reduction of urel(M(Si)) during the past decade by almost 3 orders of magnitude and thus further reduces the uncertainty of the Avogadro constant NA which is one of the preconditions for the redefinition of the SI unit kilogram.
The Environmental Technology Verification (ETV) Program, beginning as an initiative of the U.S. Environmental Protection Agency (EPA) in 1995, verifies the performance of commercially available, innovative technologies that can be used to measure environmental quality. The ETV p...
The performance evaluation of innovative and alternative environmental technologies is an integral part of the U.S. Environmental Protection Agency's (EPA) mission. Early efforts focused on evaluation technologies that supported the implementation of the Clean Air and Clean Wate...
Vijaya Saradhi, U V R; Prabhakar, S; Jagadeshwar Reddy, T; Murty, M R V S
2007-07-20
In the present paper, we report an improved ion-pair solid-phase extraction (IP-SPE) method for the analysis of alkylphosphonic acids, namely, methyl, ethyl and propylphosphonic acids, present in the aqueous sample. The aqueous sample was mixed with an ion-pair reagent, phenyltrimethylammonium hydroxide (PTMAH) and passed through activated charcoal SPE cartridge. The retained chemicals in the cartridge were extracted with methanol and analysed by gas chromatography-mass spectrometry (GC-MS) under the electron impact ionization (EI) mode. The analytes were converted to their methyl esters by pyrolytic methylation in the hot GC injection port. The recoveries of alkylphosphonic acids were above 95% and the minimum detection limits were as low as 10 ng/mL. The recovery of the test chemicals was tested with solvents, dichloromethane, n-hexane, ethyl acetate, acetone, acetonitrile and methanol. The chemicals could be efficiently extracted by the hydrophilic solvents. The method did not work at the highly acidic pH (when acidified with dilute HCl) but worked well from pH 4.0 to 14.0. The present method was also tested with other tetra-(methyl, ethyl, propyl and n-butyl)ammonium hydroxides. The test chemicals were not converted to their methyl and ethyl esters with tetramethyl and tetraethylammonium hydroxides, whereas they were converted to their corresponding propyl and n-butyl esters with tetrapropyl and tetra(n-butyl)ammonium hydroxides. The method was also applied to two highly cross-linked polymeric sorbents DSC-6S and Oasis HLB. The recovery of the chemicals on these sorbents was observed to be poor. Methylation using phenyltrimethylammonium hydroxide is non-hazardous and advantageous over methylation using diazomethane. The method was applied to the analysis of aqueous samples given in one of the official proficiency tests conducted by the Organization for the Prohibition of Chemical Weapons and all the spiked chemicals were identified as methyl esters.
2007-06-01
T ACanadaY Approved for PublicR Distribution Uln& Liquid Chromatography Electrospray Ionization Mass Spectrometric ( LC -ESI- MS) and Desorption...consumer products with chemical warfare agents or other toxic chemicals. Liquid chromatography electrospray ionization mass spectrometry ( LC -ESI-MS) and...house LC -ESI-MS and LC -ESI-MS/MS methods were evaluated for the determination of chemical warfare agents in spiked bottled water samples. The
Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael
2018-04-20
The suitability of dispersive liquid-liquid microextraction (DLLME) and gas chromatography accurate mass spectrometry (GC-MS), based on a time-of-flight (TOF) MS analyzer and using electron ionization (EI), for the characterization of volatile and semi-volatile profiles of grape marc distillates (grappa) are evaluated. DLLME conditions are optimized with a selection of compounds, from different chemical families, present in the distillate spirit. Under final working conditions, 2.5 mL of sample and 0.5 mL of organic solvents are consumed in the sample preparation process. The absolute extraction efficiencies ranged from 30 to 100%, depending on the compound. For the same sample volume, DLLME provided higher responses than solid-phase microextraction (SPME) for most of the model compounds. The GC-EI-TOF-MS records of grappa samples were processed using a data mining non-targeted search algorithm. In this way, chromatographic peaks and accurate EI-MS spectra of sample components were linked. The identities of more than 140 of these components are proposed from comparison of their accurate spectra with those in a low resolution EI-MS database, accurate masses of most intense fragment ions of known structure, and available chromatographic retention index. The use of chromatographic and spectral data, associated to the set of components mined from different grappa samples, for multivariate analysis purposes is also illustrated in the study. Copyright © 2018 Elsevier B.V. All rights reserved.
Miniaturized Environmental Monitoring Instrumentation
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. B. Freidhoff
1997-09-01
The objective of the Mass Spectrograph on a Chip (MSOC) program is the development of a miniature, multi-species gas sensor fabricated using silicon micromachining technology which will be orders of magnitude smaller and lower power consumption than a conventional mass spectrometer. The sensing and discrimination of this gas sensor are based on an ionic mass spectrograph, using magnetic and/or electrostatic fields. The fields cause a spatial separation of the ions according to their respective mass-to-charge ratio. The fabrication of this device involves the combination of microelectronics with micromechanically built sensors and, ultimately, vacuum pumps. The prototype of a chemical sensormore » would revolutionize the method of performing environmental monitoring for both commercial and government applications. The portable unit decided upon was the miniaturized gas chromatograph with a mass spectrometer detector, referred to as a GC/MS in the analytical marketplace.« less
Detection of explosives in soils
Chambers, William B.; Rodacy, Philip J.; Phelan, James M.; Woodfin, Ronald L.
2002-01-01
An apparatus and method for detecting explosive-indicating compounds in subsurface soil. The apparatus has a probe with an adsorbent material on some portion of its surface that can be placed into soil beneath the ground surface, where the adsorbent material can adsorb at least one explosive-indicating compound. The apparatus additional has the capability to desorb the explosive-indicating compound through heating or solvent extraction. A diagnostic instrument attached to the probe detects the desorbed explosive-indicating compound. In the method for detecting explosive-indicating compounds in soil, the sampling probe with an adsorbent material on at least some portion of a surface of the sampling probe is inserted into the soil to contact the adsorbent material with the soil. The explosive-indicating compounds are then desorbed and transferred as either a liquid or gas sample to a diagnostic tool for analysis. The resulting gas or liquid sample is analyzed using at least one diagnostic tool selected from the group consisting of an ion-mobility spectrometer, a gas chromatograph, a high performance liquid chromatograph, a capillary electrophoresis chromatograph, a mass spectrometer, a Fourier-transform infrared spectrometer and a Raman spectrometer to detect the presence of explosive-indicating compounds.
Singhal, Puran; Gaur, Ashwani; Gautam, Anirudh; Varshney, Brijesh; Paliwal, Jyoti; Batra, Vijay
2007-11-01
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for quantification of piperaquine, an antimalarial drug, in human plasma using its structural analogue, piperazine bis chloroquinoline as internal standard (IS). The method involved a simple protein precipitation with methanol followed by rapid isocratic elution of analytes with 10mM ammonium acetate buffer/methanol/formic acid/ammonia solution (25/75/0.2/0.15, v/v) on Chromolith SpeedROD RP-18e reversed phase chromatographic column and quantification by mass spectrometry in the multiple reaction monitoring mode (MRM). The precursor to product ion transitions of m/z 535.3-->288.2 and m/z 409.1-->205.2 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 1.0-250.2 ng/mL for piperaquine in plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) in plasma were 0.2 and 1.0 ng/mL, respectively. Acceptable precision and accuracy (+/-20% deviation for LLOQ standard and +/-15% deviation for other standards from the respective nominal concentration) were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for a sample made it possible to achieve a throughput of more than 400 plasma samples analyzed per day. The validated method was successfully applied to analyze human plasma samples from phase-1 clinical studies. The mean pharmacokinetic parameters of piperaquine following 1000 mg oral dose: observed maximum plasma concentration (Cmax), time to maximum plasma concentration (Tmax) and elimination half-life (T1/2) were 46.1 ng/mL, 3.8h and 13 days, respectively.
Chakraborty, Asish B.; Berger, Scott J.
2005-01-01
The balance between chromatographic performance and mass spectrometric response has been evaluated using an automated series of experiments where separations are produced by the real-time automated blending of water with organic and acidic modifiers. In this work, the concentration effects of two acidic modifiers (formic acid and trifluoroacetic acid) were studied on the separation selectivity, ultraviolet, and mass spectrometry detector response, using a complex peptide mixture. Peptide retention selectivity differences were apparent between the two modifiers, and under the conditions studied, trifluoroacetic acid produced slightly narrower (more concentrated) peaks, but significantly higher electrospray mass spectrometry suppression. Trifluoroacetic acid suppression of electrospray signal and influence on peptide retention and selectivity was dominant when mixtures of the two modifiers were analyzed. Our experimental results indicate that in analyses where the analyzed components are roughly equimolar (e.g., a peptide map of a recombinant protein), the selectivity of peptide separations can be optimized by choice and concentration of acidic modifier, without compromising the ability to obtain effective sequence coverage of a protein. In some cases, these selectivity differences were explored further, and a rational basis for differentiating acidic modifier effects from the underlying peptide sequences is described. PMID:16522853
Hummert, Pamela; Parsons, Teresa L; Ensign, Laura M; Hoang, Thuy; Marzinke, Mark A
2018-04-15
The nucleotide reverse transcriptase inhibitor tenofovir (TFV) is widely administered in a disoproxil prodrug form (tenofovir disoproxil fumarate, TDF) for HIV management and prevention. Recently, novel prodrugs tenofovir alafenamide fumarate (TAF) and hexadecyloxypropyl tenofovir (CMX157) have been pursued for HIV treatment while minimizing adverse effects associated with systemic TFV exposure. Dynamic and sensitive bioanalytical tools are required to characterize the pharmacokinetics of these prodrugs in systemic circulation. Two parallel methods have been developed, one to combinatorially quantify TAF and TFV, and a second method for CMX157 quantification, in plasma. K 2 EDTA plasma was spiked with TAF and TFV, or CMX157. Following the addition of isotopically labeled internal standards and sample extraction via solid phase extraction (TAF and TFV) or protein precipitation (CMX157), samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. For TAF and TFV, separation occurred using a Zorbax Eclipse Plus C18 Narrow Bore RR, 2.1 × 50 mm, 3.5 μm column and analytes were detected on an API5000 mass analyzer; CMX157 was separated using a Kinetex C8, 2.1 × 50 mm, 2.6 μm column and quantified using an API4500 mass spectrometer. Methods were validated according to FDA Bioanalytical Method Validation guidelines. Analytical methods: were optimized for the multiplexed monitoring of TAF and TFV, and CMX157 in plasma. The lower limits of quantification (LLOQs) for TAF, TFV, and CMX157 were 0.03, 1.0, and 0.25 ng/mL, respectively. Calibration curves were generated via weighted linear regression of standards. Intra- and inter-assay precision and accuracy studies demonstrated %CVs ≤ 14.4% and %DEVs ≤ ± 7.95%, respectively. Stability and matrix effects studies were also performed. All results were acceptable and in accordance with the recommended guidelines for bioanalytical methods. Assays were also applied to quantify in vivo concentrations of prodrugs and TFV in a preclinical study post-rectal administration. Sensitive, specific, and dynamic LC-MS/MS assays have been developed and validated for the multiplexed quantification TAF and TFV, as well as an independent assay for CMX157 quantification, in plasma. The described methods meet sufficient throughput criteria to support large research trials. Copyright © 2018 Elsevier B.V. All rights reserved.
Sagona, Jessica A; Dukett, James E; Hawley, Harmonie A; Mazurek, Monica A
2014-10-03
Cloud water samples from Whiteface Mountain, NY were used to develop a combined sampling and gas chromatography-mass spectrometric (GCMS) protocol for evaluating the complex mixture of highly polar organic compounds (HPOC) present in this atmospheric medium. Specific HPOC of interest were mono- and di keto-acids which are thought to originate from photochemical reactions of volatile unsaturated hydrocarbons from biogenic and manmade emissions and be a major fraction of atmospheric carbon. To measure HPOC mixtures and the individual keto-acids in cloud water, samples first must be derivatized for clean elution and measurement, and second, have low overall background of the target species as validated by GCMS analysis of field and laboratory blanks. Here, we discuss a dual derivatization method with PFBHA and BSTFA which targets only organic compounds that contain functional groups reacting with both reagents. The method also reduced potential contamination by minimizing the amount of sample processing from the field through the GCMS analysis steps. Once derivatized only gas chromatographic separation and selected ion monitoring (SIM) are needed to identify and quantify the polar organic compounds of interest. Concentrations of the detected total keto-acids in individual cloud water samples ranged from 27.8 to 329.3ngmL(-1) (ppb). Method detection limits for the individual HPOC ranged from 0.17 to 4.99ngmL(-1) and the quantification limits for the compounds ranged from 0.57 to 16.64ngmL(-1). The keto-acids were compared to the total organic carbon (TOC) results for the cloud water samples with concentrations of 0.607-3.350mgL(-1) (ppm). GCMS analysis of all samples and blanks indicated good control of the entire collection and analysis steps. Selected ion monitoring by GCMS of target keto-acids was essential for screening the complex organic carbon mixtures present at low ppb levels in cloud water. It was critical for ensuring high levels of quality assurance and quality control and for the correct identification and quantification of key marker compounds. Copyright © 2014 Elsevier B.V. All rights reserved.
Bendini, Alessandra; Bonoli, Matteo; Cerretani, Lorenzo; Biguzzi, Barbara; Lercker, Giovanni; Toschi, Tullia Gallina
2003-01-24
The high oxidative stability of virgin olive oil is related to its high monounsaturated/polyunsaturated ratio and to the presence of antioxidant compounds, such as tocopherols and phenols. In this paper, the isolation of phenolic compounds from virgin olive oil, by different methods, was tested and discussed. Particularly liquid-liquid and solid-phase extraction methods were compared, assaying, for the latter, three stationary phases (C8, C18 and Diol) and several elution mixtures. Quantification of phenolic and o-diphenolic substances in the extracts was performed by the traditional Folin-Ciocalteau method and the sodium molybdate reaction, respectively. Furthermore, the quantification of phenolic compounds in the extracts and in a standard mixture was carried out both with diode array and mass spectrometric detection and capillary zone electrophoresis.
Abidi, S.L.; Ha, S.C.; Rosen, R.T.
1990-01-01
Reversed-phase high-performance liquid chromatography—thermospray mass spectrometric (HPLC—MS) characteristics of four sets of lactonic complexes (one 4-butyrolactones and three dilactone complexes) derived from antimycin A were investigated. Three types of 8-hydroxy analogues were also included in the study. Pairs of a–b structures isomeric at the 8-acyloxy ester side-chains were best separated with a high-efficiency octadecylsilica column prior to analysis by HPLC—MS. Mass spectra of the a–b pairs each with identical molecular weights exhibited virtually indistinguishable fragmentation patterns, although their relative intensities were not superimposable. In some cases, HPLC—MS of the title compounds yielded mass chromatograms showing the minor components more easily recognizable than the HPLC—UV counter parts because of the apparent higher ionization efficiency of the minor isomers and increased resolution of subcomponents in the MS system. Under the mobile phase conditions employed, analyte ionization occurred with variable degrees of gas phase ammonolysis depending upon the ammonia concentration of the buffer. Potential applicability of the on-line HPLC—MS technique for the characterization of components in mixtures of antimycin analogues and isomers is demonstrated.
Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J.; Weimann, Allan; Poulsen, Henrik E.; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D.; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B.; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T.; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J.; Santella, Regina M.; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen
2013-01-01
Abstract Aims: Urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Results: Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed ‘spot’ samples showed strong correlations with 24 h excretion (the ‘gold’ standard) of urinary 8-oxodG (rp 0.67–0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). Innovation: This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. Conclusion: ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended. Antioxid. Redox Signal. 18, 2377–2391. PMID:23198723
AVOIDING HYDROLYSIS OF FUEL ETHER OXYGENATES DURING STATIC HEADSPACE ANALYSIS
A headspace autosampler, gas chromatograph and ion trap mass spectrometer (headspace GC/MS) were used for trace analysis of fuel oxygenates and related compounds and aromatics in water. A method has been developed for determination of methyl tert-butyl ether (MTBE), ethyl tert-b...
Analysis of Endocrine Disrupting Pesticides by Capillary GC with Mass Spectrometric Detection
Matisová, Eva; Hrouzková, Svetlana
2012-01-01
Endocrine disrupting chemicals, among them many pesticides, alter the normal functioning of the endocrine system of both wildlife and humans at very low concentration levels. Therefore, the importance of method development for their analysis in food and the environment is increasing. This also covers contributions in the field of ultra-trace analysis of multicomponent mixtures of organic pollutants in complex matrices. With this fact conventional capillary gas chromatography (CGC) and fast CGC with mass spectrometric detection (MS) has acquired a real importance in the analysis of endocrine disrupting pesticide (EDP) residues. This paper provides an overview of GC methods, including sample preparation steps, for analysis of EDPs in a variety of matrices at ultra-trace concentration levels. Emphasis is put on separation method, mode of MS detection and ionization and obtained limits of detection and quantification. Analysis time is one of the most important aspects that should be considered in the choice of analytical methods for routine analysis. Therefore, the benefits of developed fast GC methods are important. PMID:23202677
GC-MS studies on the regioisomeric methoxy-methyl-phenethylamines related to MDEA, MDMMA, and MBDB.
Thigpen, Ashley; Awad, Tamer; Deruiter, Jack; Clark, C Randall
2008-01-01
Three regioisomeric 3,4-methylenedioxyphenethylamines having the same molecular weight and major mass spectral fragments of equal mass have been reported as drugs of abuse in forensic studies in recent years. These compounds are 3,4-methylenedioxy-N-ethylamphetamine (MDEA), 3,4-methylenedioxy-N-N-dimethylamphetamine (MDMMA), and N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine (MBDB). The mass spectra of the regioisomers (4-methoxy-3-methyl and 4-methoxy-2-methyl-phenethylamines) are essentially equivalent to the three compounds reported as drugs of abuse. This project focused on the synthesis, mass spectral characterization, and chromatographic analysis of these six regioisomeric methoxy methyl phenethylamines. Additionally, the mass spectral and chromatographic properties of these compounds will be compared to the isobaric 2,3- and 3,4-methylenedioxyphenethyl-amines of the same side chain. The six regioisomeric methoxy-methyl-phenethylamines were synthesized from commercially available starting materials. Side chain differentiation by mass spectrometry was possible after the formation of the perfluoroacyl derivatives, pentafluoropropionylamides (PFPA) and heptafluorobutrylamides (HFBA). Gas chromatographic separation on Rtx-1 was successful at resolving the perfluoroacyl derivatives of the 4-methoxy-3-methyl phenethylamines from those of the 4-methoxy-2-methyl phenethylamines. The 4-methoxy-3-methyl-phenethylamine derivatives eluted before the 4-methoxy-2-methyl-phenethylamine derivatives as both the PFPA and HFBA derivatives.
Synthesis and thermal stability of carborane containing phosphazenes
NASA Technical Reports Server (NTRS)
Fewell, L. L.; Basi, R. J.; Parker, J. A.
1983-01-01
Carborane substituted polyphosphazenes were prepared by the thermal polymerization of phenyl-carboranyl penta chlorocyclotriphosphazene. Successive isothermal vacuum pyrolyses were conducted on the polymer and examined for structural changes by infrared spectroscopy. The degradation products were ascertained by gas chromatography-mass spectrometric analysis. It was found that the presence of the carborane group improves the thermal stability of the polymer by retarding the ring chain equilibrium processes of decomposition.
A MASS-SPECTROMETRIC INVESTIGATION OF SULFUR VAPOR AS A FUNCTION OF TEMPERATURE (thesis)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zietz, M.C.
1960-06-15
A mass-spectrometric investigation was performed on sulfur vapor in equilibrium with the condensed phase at 120 to 210 gas-cooled C. It was found that, in this temperature range, equilibrium sulfur vapor contains appreciable quantities of S/sub 8/, S/sub 7/, S/sub 6/, and S/sub 5/ only. The sulfur vapor emanated as a small well-collimated molecular beam from a specially constructed source into an ionization chamber which was designed to exclude from analysis any sulfur vapor that had impinged on the walls or the hot electron filament. Essential identical ionization potentials were determined for S/sub 8/ , S/sub 7/, S/sub 6/, andmore » S/sub 5/ of 9.8 0.4 ev. The heat of vaporizati on of S/sub 7/ was calculated to be approximately 2.5 kcal greater than that of S/ sub 8/. Upper limits for S/sub 8/ and S/sub 7/ composition in S vapor at 120 gas- cooled C were determined to be 86% and 14%, respectively. It is proposed thst S/sub 8/ is the vaporizing species, that S/sub 7/, S/sub 6/, and S/sub 5/ result from dissociation of S/sub 8/. and that all four molecules have a ring configuration. (auth)« less
Müller, M; Heumann, K G
2000-09-01
An isotope dilution inductively coupled plasma quadrupole mass spectrometric (ID-ICP-QMS) method was developed for the simultaneous determination of the platinum group elements Pt, Pd, Ru, and Ir in environmental samples. Spike solutions, enriched with the isotopes 194Pt, 108Pd, 99Ru, and 191Ir, were used for the isotope dilution step. Interfering elements were eliminated by chromatographic separation using an anion-exchange resin. Samples were dissolved with aqua regia in a high pressure asher. Additional dissolution of possible silicate portions by hydrofluoric acid was usually not necessary. Detection limits of 0.15 ng x g(-1), 0.075 ng x g(-1), and 0.015 ng x g(-1) were achieved for Pt, Pd, Ru, and Ir, respectively, using sample weights of only 0.2 g. The reliability of the ID-ICP-QMS method was demonstrated by analyzing a Canadian geological reference material and by participating in an interlaboratory study for the determination of platinum and palladium in a homogenized road dust sample. Surface soil, sampled at different distances from a highway, showed concentrations in the range of 0.1-87 ng x g(-1). An exponential decrease of the platinum and palladium concentration with increasing distance and a small anthropogenic contribution to the natural background concentration of ruthenium and iridium was found in these samples.
Singh, R P; Sabarinath, S; Gautam, N; Gupta, R C; Singh, S K
2009-07-15
The present manuscript describes development and validation of LC-MS/MS assay for the simultaneous quantitation of 97/78 and its active in-vivo metabolite 97/63 in monkey plasma using alpha-arteether as internal standard (IS). The method involves a single step protein precipitation using acetonitrile as extraction method. The analytes were separated on a Columbus C(18) (50 mm x 2 mm i.d., 5 microm particle size) column by isocratic elution with acetonitrile:ammonium acetate buffer (pH 4, 10 mM) (80:20 v/v) at a flow rate of 0.45 mL/min, and analyzed by mass spectrometry in multiple reaction-monitoring (MRM) positive ion mode. The chromatographic run time was 4.0 min and the weighted (1/x(2)) calibration curves were linear over a range of 1.56-200 ng/mL. The method was linear for both the analytes with correlation coefficients >0.995. The intra-day and inter-day accuracy (% bias) and precisions (% RSD) of the assay were less than 6.27%. Both analytes were stable after three freeze-thaw cycles (% deviation <8.2) and also for 30 days in plasma (% deviation <6.7). The absolute recoveries of 97/78, 97/63 and internal standard (IS), from spiked plasma samples were >90%. The validated assay method, described here, was successfully applied to the pharmacokinetic study of 97/78 and its active in-vivo metabolite 97/63 in Rhesus monkeys.
Three-step HPLC-ESI-MS/MS procedure for screening and identifying non-target flavonoid derivatives
NASA Astrophysics Data System (ADS)
Rak, Gábor; Fodor, Péter; Abrankó, László
2010-02-01
A three-step HPLC-ESI-MS/MS procedure is designed for screening and identification of non-target flavonoid derivatives of selected flavonoid aglycones. In this method the five commonly appearing aglycones (apigenin, luteolin, myricetin, naringenin and quercetin) were selected. The method consists of three individual mass spectrometric experiments of which the first two were implemented within a single chromatographic acquisition. The third step was carried out during a replicate chromatographic run using the same RP-HPLC conditions. The first step, a multiple reaction monitoring (MRM) scan of the aglycones was performed to define the number of derivatives relating to the selected aglycones. For this purpose the characteristic aglycone parts of the unknowns were used as specific tags of the molecules, which were generated as in-source fragments. Secondly, a full scan MS experiment is performed to identify the masses of the potential derivatives of the selected aglycones. Finally, the third step had the capability to confirm the supposed derivatives. The developed method was applied to a commercially available black currant juice to demonstrate its capability to detect and identify various flavonoid glycosides without any preliminary information about their presence in the sample. As a result 13 compounds were detected and identified in total. Namely, 3 different myricetin glycosides and the myricetin aglycone 2 luteolin glycosides plus the aglycone and 3 quercetin glycosides plus the aglycone could be identified from the tested black currant sample. In the case of apigenin and naringenin only the aglycones could be detected.
The performance evaluation of innovative and alternative environmental technologies is an integral part of the U.S. Environmental Protection Agency's (EPA) mission. In the spirit of the technology policy, the Agency began to direct a portion of its resources toward the promotion...
Microbial Development and Metabolic Engineering | Bioenergy | NREL
beaker filled with a green liquid cyanobacteria culture that is bubbling. Synthetic Biology We have utilized the power of synthetic biology to uncover relevant genetic factors to predictably regulate gene operating a gas chromatograph mass spectrometer. Systems Biology Our comprehensive systems biology
Investigation of Imposter Perfumes Using GC-MS
ERIC Educational Resources Information Center
Mowery, Kelly A.; Blanchard, Daniel E.; Smith, Stephanie; Betts, Thomas A.
2004-01-01
An experiment to initiate students into several features of gas chromatograph-mass spectrometers (GC-MS) through the study of branded and counterfeit perfumes is described. The experiment enables the students to appreciate the power of GC-MS in distinguishing between original and imitation perfumes, and in analyzing data with its application…
OPTIMIZATION OF HIGH-SPEED GC/TOFMS FOR METHOD TO-14 ANALYSIS
A fast GC/MS system (FGCMS) consisting of a high-speed gas chromatograph equipped with a narrow bandwidth injection accessory and a time-of-flight mass spectrometer detector is being optimized for analysis of Method TO-14 target compounds. The system consists entirely of comm...
Wohlfahrt, S; Fischer, M; Saraji-Bozorgzad, M; Matuschek, G; Streibel, T; Post, E; Denner, T; Zimmermann, R
2013-09-01
Comprehensive multi-dimensional hyphenation of a thermogravimetry device (i.e. a thermobalance) to gas chromatography and single photon ionization-time-of-flight mass spectrometry (TG-GC×SPI-MS) has been used to investigate two crude oil samples of different geographical origin. The source of the applied vacuum ultraviolet radiation is an electron beam pumped rare gas excimer lamp (EBEL). The soft photoionization favors the formation of molecular ions. Introduction of a fast, rapidly modulated gas chromatographic separation step in comparison with solely TG-SPI-MS enables strongly enhanced detection especially with such highly complex organic matrices as crude oil. In contrast with former TG-SPI-MS measurements, separation and identification of overlying substances is possible because of different GC retention times. The specific contribution of isobaric compounds to one mass signal is determined for alkanes, naphthalenes, alkylated benzenes, and other compounds.
NASA Astrophysics Data System (ADS)
Apel, E. C.; Calvert, J. G.; Riemer, D.; Pos, W.; Zika, R.; Kleindienst, T. E.; Lonneman, W. A.; Fung, K.; Fujita, E.; Shepson, P. B.; Starn, T. K.; Roberts, P. T.
1998-09-01
Simultaneous measurements of oxygenated volatile organic compounds (OVOCs) by four independent research groups at the Youth Incorporated (YI) site during the 1995 Southern Oxidants Study Nashville Intensive, between July 4 and 30, 1995, provided a unique opportunity to compare results from different techniques. 2,4-Dinitrophenylhydrazine (DNPH) coated C18 (C18AtmAA) and Si-Gel (Si-GelMTE) cartridges were compared with each other and with two sorbent-based preconcentration gas chromatographic (GC) techniques coupled with mass spectrometric (MS) detection (GC/MSUM and GC/MSPU) or flame ionization detection GC/FIDUM· The experiment consisted of both a laboratory (part A) and an ambient air comparison (part B). In part A of the study, standard mixtures of OVOCs were diluted in a flowing gas stream of humidified, purified air, both with and without addition of O3, and distributed to participant's instrumentation. Concentrations were compared with the expected values based on known cylinder concentrations and dilution factors. In part B of the study, the instruments sampled ambient air from a common glass manifold. Species intercompared were formaldehyde, acetaldehyde, acetone, and propanal. The C18AtmAA data were typically higher than the Si-GelMTE data for the four intercompared compounds, and possible explanations are given. Agreement between the cartridge systems and the GC/MS, GC/FID systems for comeasured compounds was poorer than expected but improved towards the end of the experiment. The GC/MS systems tracked each other well for acetone, but there were differences in the absolute concentration values. These results show that improvements in the accuracy and comparability of techniques should be of high priority.
A comparative mass spectrometric study of fatty acids and metals in some seed extracts.
Suvar, Sonia Niculina; Bleiziffer, R; Podea, P; Iordache, A; Voica, C; Zgavarogea, R; Culea, M
A major cause of cardiovascular diseases and cancer is diet content, so the optimization of micronutrients in food is very important. Omega-3 fatty acids supplementation for patients had beneficial effects on subjective global assessment score and metabolic profiles. Fatty acids content and the metal ions in different seeds (e.g. linseed, poppy, grape, hemp, nuts, pumpkin, sesame, watermelon, chia) recommended as food supplements, purchased on the Romanian market, were compared. Gas chromatography coupled to mass spectrometry (GC-MS) was used as an excellent technique for fatty acids identification and quantitation, and inductively coupled plasma mass spectrometer (ICP-MS) for analytical measurements of metals.
NASA Technical Reports Server (NTRS)
Pinnick, Veronica; Buch, Arnaud; VanAmerom, Friso H. W.; Danell, Ryan M.; Brinckerhoff, William; Mahaffy, Paul; Cotter, Robert J.
2011-01-01
The Mars Organic Molecule Analyzer (MOMA) is a joint venture by NASA and the European Space Agency (ESA) to develop a sensitive, light-weight, low-power mass spectrometer for chemical analysis on Mars. MOMA is a key analytical instrument aboard the 2018 ExoMars rover mission seeking signs of past or present life. The current prototype was built to demonstrate operation of gas chromatography (OC) and laser desorption (LD) mass spectrometry under martian ambient conditions (5-7 Torr of CO2-rich atmosphere). Recent reports have discussed the MO MA concept, design and performance. Here, we update the current prototype performance, focusing specifically on the GCMS mode.
NASA Astrophysics Data System (ADS)
Storey, Andrew P.; Zeiri, Offer M.; Ray, Steven J.; Hieftje, Gary M.
2017-02-01
The flowing atmospheric-pressure afterglow (FAPA) source was used for the mass-spectrometric analysis of vapor samples introduced between the source and mass spectrometer inlet. Through interrupted operation of the plasma-supporting helium flow, helium consumption is greatly reduced and dynamic gas behavior occurs that was characterized by schlieren imaging. Moreover, mass spectra acquired immediately after the onset of helium flow exhibit a signal spike before declining and ultimately reaching a steady level. This initial signal appears to be due to greater interaction of sample vapor with the afterglow of the source when helium flow resumes. In part, the initial spike in signal can be attributed to a pooling of analyte vapor in the absence of helium flow from the source. Time-resolved schlieren imaging of the helium flow during on and off cycles provided insight into gas-flow patterns between the FAPA source and the MS inlet that were correlated with mass-spectral data.
Storey, Andrew P; Zeiri, Offer M; Ray, Steven J; Hieftje, Gary M
2017-02-01
The flowing atmospheric-pressure afterglow (FAPA) source was used for the mass-spectrometric analysis of vapor samples introduced between the source and mass spectrometer inlet. Through interrupted operation of the plasma-supporting helium flow, helium consumption is greatly reduced and dynamic gas behavior occurs that was characterized by schlieren imaging. Moreover, mass spectra acquired immediately after the onset of helium flow exhibit a signal spike before declining and ultimately reaching a steady level. This initial signal appears to be due to greater interaction of sample vapor with the afterglow of the source when helium flow resumes. In part, the initial spike in signal can be attributed to a pooling of analyte vapor in the absence of helium flow from the source. Time-resolved schlieren imaging of the helium flow during on and off cycles provided insight into gas-flow patterns between the FAPA source and the MS inlet that were correlated with mass-spectral data. Graphical Abstract ᅟ.
The SRI Model 86 1 OC gas chromatograph (GC) is a transportable instrument that can provide on-site analysis of soils for explosives. Coupling this transportable gas chromatograph with a thermionic ionization detector (TID) allows for the determination of explosives in soil matri...
ERIC Educational Resources Information Center
Erskine, Steven R.; And Others
1986-01-01
Describes a laboratory experiment that is designed to aid in the understanding of the fundamental process involved in gas chromatographic separations. Introduces the Kovats retention index system for use by chemistry students to establish criteria for the optimal selection of gas chromatographic stationary phases. (TW)
NASA Technical Reports Server (NTRS)
Merritt, D. A.; Freeman, K. H.; Ricci, M. P.; Studley, S. A.; Hayes, J. M.
1995-01-01
Conditions and systems for on-line combustion of effluents from capillary gas chromatographic columns and for removal of water vapor from product streams were tested. Organic carbon in gas chromatographic peaks 15 s wide and containing up to 30 nanomoles of carbon was quantitatively converted to CO2 by tubular combustion reactors, 200 x 0.5 mm, packed with CuO or NiO. No auxiliary source of O2 was required because oxygen was supplied by metal oxides. Spontaneous degradation of CuO limited the life of CuO reactors at T > 850 degrees C. Since NiO does not spontaneously degrade, its use might be favored, but Ni-bound carbon phases form and lead to inaccurate isotopic results at T < 1050 degrees C if gas-phase O2 is not added. For all compounds tested except CH4, equivalent isotopic results are provided by CuO at 850 degrees C, NiO + O2 (gas-phase mole fraction, 10(-3)) at 1050 degrees C and NiO at 1150 degrees C. The combustion interface did not contribute additional analytical uncertainty, thus observed standard deviations of 13C/12C ratios were within a factor of 2 of shot-noise limits. For combustion and isotopic analyses of CH4, in which quantitative combustion required T approximately 950 degrees C, NiO-based systems are preferred, and precision is approximately 2 times lower than that observed for other analytes. Water must be removed from the gas stream transmitted to the mass spectrometer or else protonation of CO2 will lead to inaccuracy in isotopic analyses. Although thresholds for this effect vary between mass spectrometers, differential permeation of H2O through Nafion tubing was effective in both cases tested, but the required length of the Nafion membrane was 4 times greater for the more sensitive mass spectrometer.
Merritt, D A; Freeman, K H; Ricci, M P; Studley, S A; Hayes, J M
1995-07-15
Conditions and systems for on-line combustion of effluents from capillary gas chromatographic columns and for removal of water vapor from product streams were tested. Organic carbon in gas chromatographic peaks 15 s wide and containing up to 30 nanomoles of carbon was quantitatively converted to CO2 by tubular combustion reactors, 200 x 0.5 mm, packed with CuO or NiO. No auxiliary source of O2 was required because oxygen was supplied by metal oxides. Spontaneous degradation of CuO limited the life of CuO reactors at T > 850 degrees C. Since NiO does not spontaneously degrade, its use might be favored, but Ni-bound carbon phases form and lead to inaccurate isotopic results at T < 1050 degrees C if gas-phase O2 is not added. For all compounds tested except CH4, equivalent isotopic results are provided by CuO at 850 degrees C, NiO + O2 (gas-phase mole fraction, 10(-3)) at 1050 degrees C and NiO at 1150 degrees C. The combustion interface did not contribute additional analytical uncertainty, thus observed standard deviations of 13C/12C ratios were within a factor of 2 of shot-noise limits. For combustion and isotopic analyses of CH4, in which quantitative combustion required T approximately 950 degrees C, NiO-based systems are preferred, and precision is approximately 2 times lower than that observed for other analytes. Water must be removed from the gas stream transmitted to the mass spectrometer or else protonation of CO2 will lead to inaccuracy in isotopic analyses. Although thresholds for this effect vary between mass spectrometers, differential permeation of H2O through Nafion tubing was effective in both cases tested, but the required length of the Nafion membrane was 4 times greater for the more sensitive mass spectrometer.
Chemical Tracers as an Indicator of Transport in the UT/LS
NASA Astrophysics Data System (ADS)
Moore, F. L.; Hurst, D. F.; Elkins, J. W.; Nance, J. D.; Dutton, G. S.; Hall, B. D.
2009-12-01
Previous airborne studies have proven the scientific value of chemical tracers in examining transport of the Upper Troposphere and Lower Stratosphere (UT/LS). ESRL scientists operated two airborne gas chromatographs on the NCAR G-V during the NSF sponsored Stratosphere-Troposphere Analyses of Regional Transport START-08 campaign over the midlatitudes of central North America. The Unmanned aircraft systems Chromatograph for Atmospheric Trace Species (UCATS) is comprised of a two-channel electron capture detection-gas chromatograph (ECD-GC), an ozone absorption photometer, and a water vapor tunable diode laser spectrometer. It measures N2O and SF6 every 70 seconds on one EC-GC channel, and H2, CO, and CH4 every 140 seconds on the second channel. PAN and Trace Hydrohalocarbon ExpeRiment (PANTHER) is a six-channel gas chromatograph with four ECD-GC channels and two mass selective detector-gas chromatograph (MSD-GC) channels that double the sampling rate to 180 seconds by using two traps and columns. The ECD-GC channels measure N2O, SF6, CFC-11, CFC-12, halon-1211, and PAN once every 70 seconds, H2, CH4, and CO once every 140 seconds. The two MSD-GC channels measure methyl halides (CH3I, CH3Cl, CH3I), HCFCs (22, 141b, 142b), HFC-134a, sulfur gases (COS and CS2) once every 180 seconds. These data represent a diversity of atmospheric lifetimes and are useful in examining transport in UT/LS. One example is the tracer-tracer correlation plot of N2O versus SF6, which shows three distinction regions of transport, LS, tropospause transition, and UT. Tropospheric gradients for both gases are apparent in the UT region. Other correlations will be shown in this presentation. A comparison of common species measured between UCATS and PANTHER shows a better than one percent agreement between the two instruments.
Hsieh, Cheng-Huan; Meher, Anil Kumar; Chen, Yu-Chie
2013-01-01
Contactless atmospheric pressure ionization (C-API) method has been recently developed for mass spectrometric analysis. A tapered capillary is used as both the sampling tube and spray emitter in C-API. No electric contact is required on the capillary tip during C-API mass spectrometric analysis. The simple design of the ionization method enables the automation of the C-API sampling system. In this study, we propose an automatic C-API sampling system consisting of a capillary (∼1 cm), an aluminium sample holder, and a movable XY stage for the mass spectrometric analysis of organics and biomolecules. The aluminium sample holder is controlled by the movable XY stage. The outlet of the C-API capillary is placed in front of the orifice of a mass spectrometer, whereas the sample well on the sample holder is moved underneath the capillary inlet. The sample droplet on the well can be readily infused into the C-API capillary through capillary action. When the sample solution reaches the capillary outlet, the sample spray is readily formed in the proximity of the mass spectrometer applied with a high electric field. The gas phase ions generated from the spray can be readily monitored by the mass spectrometer. We demonstrate that six samples can be analyzed in sequence within 3.5 min using this automatic C-API MS setup. Furthermore, the well containing the rinsing solvent is alternately arranged between the sample wells. Therefore, the C-API capillary could be readily flushed between runs. No carryover problems are observed during the analyses. The sample volume required for the C-API MS analysis is minimal, with less than 1 nL of the sample solution being sufficient for analysis. The feasibility of using this setup for quantitative analysis is also demonstrated.
A Small-Scale Low-Cost Gas Chromatograph
ERIC Educational Resources Information Center
Gros, Natasa; Vrtacnik, Margareta
2005-01-01
The design and application of a small-scale portable gas chromatograph for learning of the basic concepts of chromatography is described. The apparatus consists of two basic separable units, which includes a chromatographic unit and an electronic unit.
The stability of the active medium of RF-exited CO2 lasers with gold as catalyst
NASA Astrophysics Data System (ADS)
Cherezov, V. M.; Novgorodov, M. Z.; Ochkin, V. N.; Samorodov, V. G.; Shishkanov, E. F.; Stepanov, V. A.; Witteman, W. J.
Using mass-spectrometric investigations the gas composition of the active medium of sealed-off cw RF-excited CO2 waveguide lasers have been studied. It has been found that a low degree of CO2 dissociation and a laser power improvement can be achieved by means of a gold catalyst in the laser discharge volume. The conditions for long operational lifetimes of these lasers are described.
Wujcik, Chad E; Kadar, Eugene P
2008-10-01
Six chromatographically resolved sulopenem prodrugs were monitored for their potential to undergo both in-source collision-induced dissociation (CID) and thermolysis. Initial Q1 scans for each prodrug revealed the formation of intense [Prodrug2 + H]+, [Prodrug2 + Na]+, [Prodrug + Na]+, and [Sulopenem + Na]+ ions. Non-adduct-associated sulopenem ([Sulopenem + H]+) along with several additional lower mass ions were also observed. Product ion scans of [Prodrug3 + Na]+ showed the retention of the sodium adduct in the collision cell continuing down to opening of the beta-lactam ring. In-source CID and temperature experiments were conducted under chromatographic conditions while monitoring several of the latter ion transitions (i.e., adducts, dimers and degradants/fragments) for a given prodrug. The resulting ion profiles indicated the regions of greatest stability for temperature and declustering potential (DP) that provided the highest signal intensity for each prodrug and minimized in-source degradation. The heightened stability of adduct ions, relative to their appropriate counterpart (i.e., dimer to dimer adduct and prodrug to prodrug adduct ions), was observed under elevated temperature and DP conditions. The addition of 100 microM sodium to the mobile phase further enhanced the formation of these more stable adduct ions, yielding an optimal [Prodrug + Na]+ ion signal at temperatures from 400 to 600 degrees C. A clinical liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay for sulopenem prodrug PF-04064900 in buffered whole blood was successfully validated using sodium-fortified mobile phase and the [PF-04064900 + Na]+ ion for quantitation. A conservative five-fold increase in sensitivity from previously validated preclinical assays using the [PF-04064900 + H]+ precursor ion was achieved.
Huang, Z H; Gage, D A; Bieber, L L; Sweeley, C C
1991-11-15
A novel approach to the analysis of acylcarnitines has been developed. It involves a direct esterification using propyl chloroformate in aqueous propanol followed by ion-pair extraction with potassium iodide into chloroform and subsequent on-column N-demethylation of the resulting acylcarnitine propyl ester iodides. The products, acyl N-demethylcarnitine propyl esters, are volatile and are easily analyzed by gas chromatography-chemical ionization mass spectrometry. For medium-chain-length (C4-C12) acylcarnitine standards, detection limits are demonstrated to be well below 1 ng starting material using selected ion monitoring. Well-separated gas chromatographic peaks and structure-specific mass spectra are obtained with samples of synthetic and biological origin. Seven acylcarnitines have been characterized in the urine of a patient suffering from medium-chain acyl-CoA dehydrogenase deficiency.
NASA Astrophysics Data System (ADS)
Chiantore, Oscar; Riedo, Chiara; Scalarone, Dominique
2009-07-01
Plant gums are complex polysaccharides used in the field of cultural heritage especially as binding media. Classification of polysaccharides may be achieved on the basis of monosaccharides composition after cleavage of glycosidic bond. Characterization of plant gums in works of art is complicated by the necessity of to use a method minimally invasive and requiring a small mount of sample. Pyrolisys is an useful method to obtain polysaccharides decomposition and generally pyrolysis products can be identified by the use of gas chromatography-mass spectrometry. This paper describes a method where two plant gums, arabic and tragacanth, were pyrolized in presence of silylating agents (HMDS e BSTFA alone and with TMCS as catalyst) using an on-line Py-GC/MS apparatus. Some characteristic trimethylsilyl derivatives of monosaccharides were identified on the basis of mass spectra. The presence of characteristic pyrolysis products of sugars allows to distinguish the two gums.
Wu, Xiao; Lintelmann, Jutta; Klingbeil, Sophie; Li, Jie; Wang, Hao; Kuhn, Evelyn; Ritter, Sebastian; Zimmermann, Ralf
2017-09-01
The influence of different exposures to PM 2.5 (particulate matter with an aerodynamic diameter below 2.5 μm) on the concentrations of biomarkers of exposure and oxidative stress should be investigated. For this purpose, urine samples from individuals travelling from Germany to China were collected and analysed. Robust LC and LC-MS/MS methods were established for the determination of biomarkers including 8-hydroxy-2'-deoxyguanosine, malondialdehyde, F 2α -isoprostanes and hydroxylated polycyclic aromatic hydrocarbons. As a pilot study, nine volunteers travelled from Germany (mean daily concentration of PM 2.5 : 21 μg/m 3 ) to China (mean daily concentration of PM 2.5 : 108 μg/m 3 ). Urine samples were collected before and after the trip. In samples collected after return to Germany, the median concentrations of oxidative stress biomarkers were observed to be higher than in samples collected before leaving Germany. Decreasing trends were observed in the sequences of samples collected after return in the following weeks. Correlations were found between exposure and oxidative stress biomarkers. Travellers are ideal models for PM pollution-induced acute health effects study. Exposure to PM pollution can cause oxidative stress and damage.
Ultrafast quantification of β-lactam antibiotics in human plasma using UPLC-MS/MS.
Carlier, Mieke; Stove, Veronique; De Waele, Jan J; Verstraete, Alain G
2015-01-26
There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a fast ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, cefuroxime, ceftazidime, meropenem and piperacillin with minimal turn around time. Sample clean-up included protein precipitation with acetonitrile containing 5 deuterated internal standards, and subsequent dilution of the supernatant with water after centrifugation. Runtime was only 2.5 min. Chromatographic separation was performed on a Waters Acquity UPLC system using a BEH C18 column (1.7 μm, 100 mm × 2.1 mm) applying a binary gradient elution of water and methanol both containing 0.1% formic acid and 2 mmol/L ammonium acetate on a Water TQD instrument in MRM mode. All compounds were detected in electrospray positive ion mode and could be quantified between 1 and 100 mg/L for amoxicillin and cefuroxime, between 0.5 and 80 mg/L for meropenem and ceftazidime, and between 1 and 150 mg/L for piperacillin. The method was validated in terms of precision, accuracy, linearity, matrix effect and recovery and has been compared to a previously published UPLC-MS/MS method. Copyright © 2014 Elsevier B.V. All rights reserved.
Alvarez, J G; Storey, B T; Hemling, M L; Grob, R L
1990-06-01
The high-resolution one- and two-dimensional proton nuclear magnetic resonance (1H-NMR) characterization of seminolipid from bovine spermatozoa is presented. The 1H-NMR data was confirmed by gas-liquid chromatography-mass spectrometric analysis of the partially methylated alditol acetates of the sugar unit, mild alkaline methanolysis of the glyceryl ester, mobility on normal phase and diphasic thin-layer chromatography (HPTLC), and fast atom bombardment mass spectrometry (FAB-MS). The structure of the molecule corresponds to 1-O-hexadecyl-2-O-hexadecanoyl-3-O-beta-D-(3'-sulfo)-galactopyranosyl- sn-glycerol.
Low-cost, compact, cooled photomultiplier assembly for use in magnetic fields up to 1400 Gauss
NASA Technical Reports Server (NTRS)
Patch, R. W.; Tashjian, R. A.; Jentner, T. A.
1975-01-01
Use of vortex tube for cooling and concentric shielding have produced smaller and more compact unit than was previously available. Future uses of device could include installation in gas chromatographs and mass spectrometers. Additional uses would include measurements and controls in magnetohydrodynamic power generators and fusion reactors.
Fatty acid composition of intramuscular fat from pastoral yak and Tibetan sheep
USDA-ARS?s Scientific Manuscript database
Fatty acid (FA) composition of intramuscular fat from mature male yak (n=6) and mature Tibetan sheep (n=6) grazed on the same pasture in the Qinghai-Tibetan Plateau was analyzed by gas chromatograph/mass spectrometer to characterize fat composition of these species and to evaluate possible differenc...
USDA-ARS?s Scientific Manuscript database
: Wings and legs of the gregarious desert locust, Schistocerca gregaria have been shown to be release sites of phenylacetonitrile (PAN), the major adult male-produced pheromone. However, there is limited information on the distribution of PAN within the locust. Here we show, using gas chromatograph...
Identification of alkyl carbazoles and alkyl benzocarbazoles in Brazilian petroleum derivatives.
Oliveira, Eniz Conceição; Vaz de Campos, Maria Cecília; Rodrigues, Maria Regina Alves; Pérez, Valéria Flores; Melecchi, Maria Inês Soares; Vale, Maria Goreti Rodrigues; Zini, Cláudia Alcaraz; Caramão, Elina Bastos
2006-02-10
Carbozoles are important compounds in crude oils, as they may be used as geochemical tracers, being the major type of nitrogen compounds in petroleum. At the same time, they are regarded as undesirable due to the problems they may cause in the refining process, such as catalyst poisoning, corrosion, gum or color formation in final products. As separation and identification of carbazoles are challenging goals, this work presents a chromatographic method, made of a pre-fractionation on neutral alumina followed by the separation and identification of two classes of carbazoles using FeCl(3)/Chromossorb W and gas chromatograph with mass spectrometer (GC/MS) (SIM-single ion monitoring mode) analysis. For the first time, a series of alkyl carbazoles and alkyl benzocarbazoles were identified in heavy gas oil (HGO) and atmospheric residue of distillation (ARD) obtained from Brazilian petroleum.
Volatile aroma compounds in various brewed green teas.
Lee, Jeehyun; Chambers, Delores H; Chambers, Edgar; Adhikari, Koushik; Yoon, Youngmo
2013-08-20
This study identifies and semi-quantifies aroma volatiles in brewed green tea samples. The objectives of this study were to identify using a gas chromatograph-mass spectrometer (GC-MS) paired with a headspace solid-phase micro-extraction (HS-SPME) the common volatile compounds that may be responsible for aroma/flavor of the brewed liquor of a range of green tea samples from various countries as consumed and to determine if green teas from the same region have similarities in volatile composition when green tea samples are prepared for consumption. Twenty-four green tea samples from eight different countries were brewed as recommended for consumer brewing. The aroma volatiles were extracted by HS-SPME, separated on a gas chromatograph and identified using a mass spectrometer. Thirty-eight compounds were identified and the concentrations were semi-quantified. The concentrations were lower than those reported by other researchers, probably because this research examined headspace volatiles from brewed tea rather than solvent extraction of leaves. No relationship to country of origin was found, which indicates that other factors have a greater influence than country of origin on aroma.
Bustamante, Luis; Cárdenas, Diana; von Baer, Dietrich; Pastene, Edgar; Duran-Sandoval, Daniel; Vergara, Carola; Mardones, Claudia
2017-09-01
Miniaturized sample pretreatments for the analysis of phenolic metabolites in plasma, involving protein precipitation, enzymatic deconjugation, extraction procedures, and different derivatization reactions were systematically evaluated. The analyses were conducted by gas chromatography with mass spectrometry for the evaluation of 40 diet-derived phenolic compounds. Enzyme purification was necessary for the phenolic deconjugation before extraction. Trimethylsilanization reagent and two different tetrabutylammonium salts for derivatization reactions were compared. The optimum reaction conditions were 50 μL of trimethylsilanization reagent at 90°C for 30 min, while tetrabutylammonium salts were associated with loss of sensitivity due to rapid activation of the inert gas chromatograph liner. Phenolic acids extractions from plasma were optimized. Optimal microextraction by packed sorbent performance was achieved using an octadecylsilyl packed bed and better recoveries for less polar compounds, such as methoxylated derivatives, were observed. Despite the low recovery for many analytes, repeatability using an automated extraction procedure in the gas chromatograph inlet was 2.5%. Instead, using liquid-liquid microextraction, better recoveries (80-110%) for all analytes were observed at the expense of repeatability (3.8-18.4%). The phenolic compounds in gerbil plasma samples, collected before and 4 h after the administration of a calafate extract, were analyzed with the optimized methodology. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Krishna, A. Chaitanya; Sathiyaraj, M.; Saravanan, R. S.; Chelladurai, R.; Vignesh, R.
2012-01-01
A simple, rapid, specific and sensitive liquid chromatography tandem mass spectrometric method has been developed and validated for the determination of doxycycline from the human plasma. Doxycycline is extracted from human plasma by solid phase extraction. Demeclocycline was used as an internal standard. Detection was performed at transitions of 444.800→428.200 for doxycycline and 464.700→448.100 for demeclocycline using mass spectrometry. Chromatographic separation of analyte and internal standard were carried out using a reverse phase C18, column at 0.500 ml/min flow. The assay of doxycycline is linear over the range of 0.055-7.612 μg/ml, with a precision <14.83%, regression coefficient (r2)=0.9961 and the limit of quantification in plasma for doxycycline was 0.055 μg/ml. Mean extraction recovery obtained was 95.55%. Samples are stable at room temperature for 6 h, processed samples were stable at least for 30.20 h and also stable at three freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in human plasma. PMID:23798780
Ancillotti, Claudia; Ciofi, Lorenzo; Rossini, Daniele; Chiuminatto, Ugo; Stahl-Zeng, Jianru; Orlandini, Serena; Furlanetto, Sandra; Del Bubba, Massimo
2017-02-01
Ultra-high-performance liquid chromatography coupled with high-resolution quadrupole-time of flight mass spectrometry with both negative and positive ionization was used for comprehensively investigating the phenolic and polyphenolic compounds in berries from three spontaneous or cultivated Vaccinium species (i.e., Vaccinium myrtillus, Vaccinium uliginosum subsp. gaultherioides, and Vaccinium corymbosum). More than 200 analytes, among phenolic and polyphenolic compounds belonging to the classes of anthocyanins, monomeric and oligomeric flavonols, flavanols, dihydrochalcones, phenolic acids, together with other polyphenolic compounds of mixed structural characteristics, were identified. Some of the polyphenols herein investigated, such as anthocyanidin glucuronides and malvidin-feruloyl-hexosides in V. myrtillus, or anthocyanindin aldopentosides and coumaroyl-hexosides in V. uliginosum subsp. gaultherioides and a large number of proanthocyanidins with high molecular weight in all species, were described for the first time in these berries. Principal component analysis applied on original LC-TOF data, acquired in survey scan mode, successfully discriminated the three Vaccinium berry species investigated, on the basis of their polyphenolic composition, underlying one more time the fundamental role of mass spectrometry for food characterization.
Brünen, Sonja; Krüger, Ralf; Finger, Susann; Korf, Felix; Kiefer, Falk; Wiedemann, Klaus; Lackner, Karl J; Hiemke, Christoph
2010-02-01
We present data for a comparison of a liquid-chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) and a high-performance liquid-chromatographic method with column switching and UV spectrophotometric detection. The two methods were developed for determination of naltrexone and 6beta-naltrexol in blood serum or plasma aiming to be used for therapeutic drug monitoring to guide the treatment of patients with naltrexone. For the high-performance liquid chromatography (HPLC)/UV detection, online sample cleanup was conducted on Perfect Bond C(18) material with 2% (vol/vol) acetonitrile in deionized water. Drugs were separated on a C(18) column using 11.5% (vol/vol) acetonitrile and 0.4% (vol/vol) N,N,N,N-tetramethylethylenediamine within 20 min. LC-MS/MS used naltrexone-d (3) and 6beta-naltrexol-d (4) as internal standards. After protein precipitation, the chromatographic separation was performed on a C(18) column by applying a methanol gradient (5-100%, vol/vol) with 0.1% formic acid over 9.5 min. The HPLC/UV method was found to be linear for concentrations ranging from 2 to 100 ng/ml, with a regression correlation coefficient of r (2) > 0.998 for naltrexone and 6beta-naltrexol. The limit of quantification was 2 ng/ml for naltrexone and 6beta-naltrexol. For the LC-MS/MS method the calibration curves were linear (r(2) > 0.999) from 0.5 to 200 ng/ml for both substances, and the limit of quantification was 0.5 ng/ml. The concentrations measured by the two methods correlated significantly for both substances (r(2) > 0.967; p < 0.001). Both methods could be used for therapeutic drug monitoring. The HPLC/UV method was advantageous regarding automatization and costs, whereas LC-MS/MS was superior with regard to sensitivity.
Intrinsic Bioprobes, Inc. (Tempe, AZ)
Nelson, Randall W [Phoenix, AZ; Williams, Peter [Phoenix, AZ; Krone, Jennifer Reeve [Granbury, TX
2008-07-15
Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.
[Mass-spectrometric analysis of an anti-microbial preparation decamethoxine].
Sukhodub, L F; Kosevich, M V; Shelkovskiĭ, V S; Volianskiĭ, Iu L
1989-11-01
I. I. Mechnikov Kharkov Research Institute of Microbiology, Vaccines and Sera, Ministry of Public Health of the Ukrainian SSR. The results of mass spectrometric investigation of decamethoxine++, an antimicrobial chemotherapeutic drug, are presented. It was shown that desorption-field mass spectrometry provided recording decamethoxine++ intensive quasimolecular ions [M.Cl]+ and [M]++ forming under conditions of high electric intensity only from the intact parent molecule. Hence, the presence of the peaks in the desorption field mass spectra made it possible to definitively determine decamethoxine++ in the samples. Therefore, the procedure of desorption-field mass spectrometry proved reliable in identification of bisquaternary ammonium compounds. Ways for thermal decomposition and mass spectrometric fragmentation of the decamethoxine++ molecule under various ionization conditions are also discussed.
Gas-Chromatographic Determination Of Water In Freon PCA
NASA Technical Reports Server (NTRS)
Melton, Donald M.
1994-01-01
Gas-chromatographic apparatus measures small concentrations of water in specimens of Freon PCA. Testing by use of apparatus faster and provides greater protection against accidental contamination of specimens by water in testing environment. Automated for unattended operation. Also used to measure water contents of materials, other than Freon PCA. Innovation extended to development of purgeable sampling accessory for gas chromatographs.
Gas chromatograph sample-transfer valve
NASA Technical Reports Server (NTRS)
Wang, W. S.; Wright, H. W., Jr.
1971-01-01
Slide-type gate valve incorporates sampling volume and transfer passageway for guiding a metered quantity of gas from pressurized test cell to gas chromatograph. Gate is moved by pneumatic bellows-type actuator.
On-line gas chromatographic analysis of airborne particles
Hering, Susanne V [Berkeley, CA; Goldstein, Allen H [Orinda, CA
2012-01-03
A method and apparatus for the in-situ, chemical analysis of an aerosol. The method may include the steps of: collecting an aerosol; thermally desorbing the aerosol into a carrier gas to provide desorbed aerosol material; transporting the desorbed aerosol material onto the head of a gas chromatography column; analyzing the aerosol material using a gas chromatograph, and quantizing the aerosol material as it evolves from the gas chromatography column. The apparatus includes a collection and thermal desorption cell, a gas chromatograph including a gas chromatography column, heated transport lines coupling the cell and the column; and a quantization detector for aerosol material evolving from the gas chromatography column.
Thevis, Mario; Thomas, Andreas; Schänzer, Wilhelm
2014-12-01
With the growing availability of mature systems and strategies in biotechnology and the continuously expanding knowledge of cellular processes and involved biomolecules, human sports drug testing has become a considerably complex field in the arena of analytical chemistry. Proving the exogenous origin of peptidic drugs and respective analogs at lowest concentration levels in biological specimens (commonly blood, serum and urine) of rather limited volume is required to pursue an action against cheating athletes. Therefore, approaches employing chromatographic-mass spectrometric, electrophoretic, immunological and combined test methods have been required and developed. These allow detecting the misuse of peptidic compounds of lower (such as growth hormone-releasing peptides, ARA-290, TB-500, AOD-9604, CJC-1295, desmopressin, luteinizing hormone-releasing hormones, synacthen, etc.), intermediate (e.g., insulins, IGF-1 and analogs, 'full-length' mechano growth factor, growth hormone, chorionic gonadotropin, erythropoietin, etc.) and higher (e.g., stamulumab) molecular mass with desired specificity and sensitivity. A gap between the technically possible detection and the day-to-day analytical practice, however, still needs to be closed.
Nguyen, Thao T; Parat, Marie-Odile; Hodson, Mark P; Pan, Jenny; Shaw, Paul N; Hewavitharana, Amitha K
2015-12-24
In traditional medicine, Carica papaya leaf has been used for a wide range of therapeutic applications including skin diseases and cancer. In this study, we investigated the in vitro cytotoxicity of aqueous and ethanolic extracts of Carica papaya leaves on the human oral squamous cell carcinoma SCC25 cell line in parallel with non-cancerous human keratinocyte HaCaT cells. Two out of four extracts showed a significantly selective effect towards the cancer cells and were found to contain high levels of phenolic and flavonoid compounds. The chromatographic and mass spectrometric profiles of the extracts obtained with Ultra High Performance Liquid Chromatography-Quadrupole Time of Flight-Mass Spectrometry were used to tentatively identify the bioactive compounds using comparative analysis. The principal compounds identified were flavonoids or flavonoid glycosides, particularly compounds from the kaempferol and quercetin families, of which several have previously been reported to possess anticancer activities. These results confirm that papaya leaf is a potential source of anticancer compounds and warrant further scientific investigation to validate the traditional use of papaya leaf to treat cancer.
Nguyen, Thao T.; Parat, Marie-Odile; Hodson, Mark P.; Pan, Jenny; Shaw, Paul N.; Hewavitharana, Amitha K.
2015-01-01
In traditional medicine, Carica papaya leaf has been used for a wide range of therapeutic applications including skin diseases and cancer. In this study, we investigated the in vitro cytotoxicity of aqueous and ethanolic extracts of Carica papaya leaves on the human oral squamous cell carcinoma SCC25 cell line in parallel with non-cancerous human keratinocyte HaCaT cells. Two out of four extracts showed a significantly selective effect towards the cancer cells and were found to contain high levels of phenolic and flavonoid compounds. The chromatographic and mass spectrometric profiles of the extracts obtained with Ultra High Performance Liquid Chromatography-Quadrupole Time of Flight-Mass Spectrometry were used to tentatively identify the bioactive compounds using comparative analysis. The principal compounds identified were flavonoids or flavonoid glycosides, particularly compounds from the kaempferol and quercetin families, of which several have previously been reported to possess anticancer activities. These results confirm that papaya leaf is a potential source of anticancer compounds and warrant further scientific investigation to validate the traditional use of papaya leaf to treat cancer. PMID:26712788
Anderson, M A; Wachs, T; Henion, J D
1997-02-01
A method based on ionspray liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed for the determination of reserpine in equine plasma. A comparison was made of the isolation of reserpine from plasma by liquid-liquid extraction and by solid-phase extraction. A structural analog, rescinnamine, was used as the internal standard. The reconstituted extracts were analyzed by ionspray LC/MS/MS in the selected reaction monitoring (SRM) mode. The calibration graph for reserpine extracted from equine plasma obtained using liquid-liquid extraction was linear from 10 to 5000 pg ml-1 and that using solid-phase extraction from 100 to 5000 pg ml-1. The lower level of quantitation (LLQ) using liquid-liquid and solid-phase extraction was 50 and 200 pg ml-1, respectively. The lower level of detection for reserpine by LC/MS/MS was 10 pg ml-1. The intra-assay accuracy did not exceed 13% for liquid-liquid and 12% for solid-phase extraction. The recoveries for the LLQ were 68% for liquid-liquid and 58% for solid-phase extraction.
Hustoft, Hanne Kolsrud; Brandtzaeg, Ole Kristian; Rogeberg, Magnus; Misaghian, Dorna; Torsetnes, Silje Bøen; Greibrokk, Tyge; Reubsaet, Léon; Wilson, Steven Ray; Lundanes, Elsa
2013-12-16
Reliable, sensitive and automatable analytical methodology is of great value in e.g. cancer diagnostics. In this context, an on-line system for enzymatic cleavage of proteins, subsequent peptide separation by liquid chromatography (LC) with mass spectrometric detection has been developed using "sub-chip" columns (10-20 μm inner diameter, ID). The system could detect attomole amounts of isolated cancer biomarker progastrin-releasing peptide (ProGRP), in a more automatable fashion compared to previous methods. The workflow combines protein digestion using an 20 μm ID immobilized trypsin reactor with a polymeric layer of 2-hydroxyethyl methacrylate-vinyl azlactone (HEMA-VDM), desalting on a polystyrene-divinylbenzene (PS-DVB) monolithic trap column, and subsequent separation of resulting peptides on a 10 μm ID (PS-DVB) porous layer open tubular (PLOT) column. The high resolution of the PLOT columns was maintained in the on-line system, resulting in narrow chromatographic peaks of 3-5 seconds. The trypsin reactors provided repeatable performance and were compatible with long-term storage.
Zubel, Tabea; Bürkle, Alexander; Mangerich, Aswin
2018-09-01
The bi-functional chemical warfare agent sulfur mustard (SM), whose release in asymmetric conflicts or terrorist attacks represents a realistic threat, induces several kinds of biomolecular adducts, including highly toxic DNA adducts. Isotope dilution liquid chromatographic tandem mass spectrometry (ID-LC-MS/MS) is considered the gold standard for highly accurate, precise, specific and sensitive quantification of DNA adducts in general. Recently, a number of LC-MS/MS approaches have been established to analyze SM-induced protein and DNA adducts in cell culture and rodent animal models. As DNA adducts are mechanism-based biomarkers for SM exposure, results from such studies provide a deeper understanding of the etiology of SM-induced pathologies, especially of long-term effects such as cancer formation. As a result, medical treatment of SM-exposed individuals might be improved. Yet, despite the progress that has been made during the last years, there is still a need for advanced methods of ID-LC-MS/MS for the detection and quantitation of SM adducts. Copyright © 2017 Elsevier B.V. All rights reserved.
Ding, Hui; Ding, Wanjing; Ma, Zhongjun
2017-03-22
Two prenylated indole alkaloids were isolated from the ethyl acetate extracts of a marine-derived fungus Penicillium sp. NH-SL and one of them exhibited potent cytotoxic activity against mouse hepa 1c1c7 cells. In order to detect other bioactive analogs, we used liquid chromatogram tandem mass spectrometry (LC-MS/MS) to analyze the mass spectrometric characteristics of the isolated compounds as well as the crude extracts. As a result, three other analogs were detected, and their structures were deduced according to the similar fragmentation patterns. This is the first systematic report on the mass spectrometric characteristics of prenylated indole derivatives.
Microfabricated packed gas chromatographic column
Kottenstette, Richard; Matzke, Carolyn M.; Frye-Mason, Gregory C.
2003-12-16
A new class of miniaturized gas chromatographic columns has been invented. These chromatographic columns are formed using conventional micromachining techniques, and allow packed columns having lengths on the order of a meter to be fabricated with a footprint on the order of a square centimeter.
Jiang, Wanfeng; Zhang, Ning; Zhang, Fengyan; Yang, Zhao
2017-07-08
A method for the determination of the content of olive oil in olive blend oil by headspace gas chromatography-mass spectrometry (SH-GC/MS) was established. The amount of the sample, the heating temperature, the heating time, the amount of injection, the injection mode and the chromatographic column were optimized. The characteristic compounds of olive oil were found by chemometric method. A sample of 1.0 g was placed in a 20 mL headspace flask, and heated at 180℃ for 2700 s. Then, 1.0 mL headspace gas was taken into the instrument. An HP-88 chromatographic column was used for the separation and the analysis was performed by GC/MS. The results showed that the linear range was 0-100%(olive oil content). The linear correlation coefficient ( r 2 ) was more than 0.995, and the limits of detection were 1.26%-2.13%. The deviations of olive oil contents in the olive blend oil were from -0.65% to 1.02%, with the relative deviations from -1.3% to 6.8% and the relative standard deviations from 1.18% to 4.26% ( n =6). The method is simple, rapid, environment friendly, sensitive and accurate. It is suitable for the determination of the content of olive oil in olive blend oil.
NASA Technical Reports Server (NTRS)
Ehrenfreund, P.; Boon, J. J.; Commandeur, J.; Sagan, C.; Thompson, W. R.; Khare, B.
1995-01-01
Comparative pyrolysis mass spectrometric data of Titan aerosol analogs, called 'tholins', are presented. The Titan tholins were produced in the laboratory at Cornell by irradiation of simulated Titan atmospheres with high energy electrons in plasma discharge. Mass-spectrometry measurements were performed at FOM of the solid phase of various tholins by Curie-point pyrolysis Gas-Chromatography/Mass-Spectrometry (GCMS) and by temperature resolved in-source Pyrolysis Mass-Spectrometry to reveal the composition and evolution temperature of the dissociation products. The results presented here are used to further define the ACP (Aerosol Collector Pyrolyser)-GCMS experiment and provide a basis for modelling of aerosol composition on Titan and for the iterpretation of Titan atmosphere data from the Huygens probe in the future.
Hypercholesterolemia Impaired Sperm Functionality in Rabbits
Monclus, Maria A.; Cabrillana, Maria E.; Clementi, Marisa A.; Espínola, Leandro S.; Cid Barría, Jose L.; Vincenti, Amanda E.; Santi, Analia G.; Fornés, Miguel W.
2010-01-01
Hypercholesterolemia represents a high risk factor for frequent diseases and it has also been associated with poor semen quality that may lead to male infertility. The aim of this study was to analyze semen and sperm function in diet-induced hypercholesterolemic rabbits. Twelve adult White New Zealand male rabbits were fed ad libitum a control diet or a diet supplemented with 0.05% cholesterol. Rabbits under cholesterol-enriched diet significantly increased total cholesterol level in the serum. Semen examination revealed a significant reduction in semen volume and sperm motility in hypercholesterolemic rabbits (HCR). Sperm cell morphology was seriously affected, displaying primarily a “folded head”-head fold along the major axe-, and the presence of cytoplasmic droplet on sperm flagellum. Cholesterol was particularly increased in acrosomal region when detected by filipin probe. The rise in cholesterol concentration in sperm cells was determined quantitatively by Gas chromatographic-mass spectrometric analyses. We also found a reduction of protein tyrosine phosphorylation in sperm incubated under capacitating conditions from HCR. Interestingly, the addition of Protein Kinase A pathway activators -dibutyryl-cyclic AMP and iso-butylmethylxanthine- to the medium restored sperm capacitation. Finally, it was also reported a significant decrease in the percentage of reacted sperm in the presence of progesterone. In conclusion, our data showed that diet-induced hypercholesterolemia adversely affects semen quality and sperm motility, capacitation and acrosomal reaction in rabbits; probably due to an increase in cellular cholesterol content that alters membrane related events. PMID:20976152
Wei, Xiuli; Wang, Chunqing; Zhang, Chunhui; Li, Xia; Wang, Jinzhi; Li, Hai; Tang, Chunhong
2017-02-01
A combination of quantitative marinating and Maillard reaction was investigated by adding d-xylose, l-cysteine and thiamine to the marinated brine of quantitative marinating, which was expected to enhance the volatile flavor of Chinese marinated chicken. Response surface methodology was used to optimize parameters, in which response was sensory evaluation scores of marinated chicken. A Box-Behnken center design was applied to the optimized added contents. The optimized contents were d-xylose (1-5‰), l-cysteine (1-5‰) and thiamine (1-3‰). Analysis of variance indicated that a second-order polynomial equation could predict the experimental data well (R 2 = 0.94), and sensory evaluation scores were significantly affected by the added amount of d-xylose, l-cysteine and thiamine. The optimal conditions that maximized the sensory evaluation score of Chinese marinated chicken were found to be 4.96‰ d-xylose, 2.28‰ l-cysteine and 2.66‰ thiamine (w/w). Given these optimal conditions, a number of meat-like flavor compounds such as 2-pentyl-furan, benzothiazole and 4-methyl-5-thiazoleethanol were identified by gas chromatographic-mass spectrometric analysis. Our results suggested that a combination of quantitative marinating and Maillard reaction might be a promising method to enhance the volatile flavor, especially meat-like flavor, of Chinese marinated chicken. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Papoutsis, Ioannis I; Athanaselis, Sotirios A; Nikolaou, Panagiota D; Pistos, Constantinos M; Spiliopoulou, Chara A; Maravelias, Constantinos P
2010-08-01
Benzodiazepines are used widely in daily clinical practice, due to their multiple pharmacological actions. The frequent problems associated with the wide use of benzodiazepines, as well as the multiple incidents of poisonings, led to the necessity for the development of a precise, sensitive and rapid method for the simultaneous determination of the 23 most commonly used benzodiazepines (diazepam, nordiazepam, oxazepam, bromazepam, alprazolam, lorazepam, medazepam, flurazepam, fludiazepam, tetrazepam, chlordiazepoxide, clobazam, midazolam, flunitrazepam, 7-amino-flunitrazepam, triazolam, prazepam, nimetazepam, nitrazepam, temazepam, lormetazepam, clonazepam, camazepam) in blood. A gas chromatographic method combined with mass spectrometric detection was developed, optimized and validated for the determination of the above substances. This method includes liquid-liquid extraction with chloroform at pH 9 and two stages of derivatization using tetramethylammonium hydroxide and propyliodide (propylation), as well as a mixture of triethylamine:propionic anhydride (propionylation). The recoveries were higher than 74% for all the benzodiazepines. The calibration curves were linear within the dynamic range of each benzodiazepine with a correlation coefficient higher than 0.9981. The limits of detection and quantification for each analyte were statistically calculated from the relative calibration curves. Accuracy and precision were also calculated and were found to be less than 8.5% and 11.1%, respectively. The developed method was successfully applied for the investigation of both forensic and clinical toxicological cases of accidental and suicidal poisoning. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Mass spectrometric screening of ligands with lower off-rate from a clicked-based pooled library.
Arai, Satoshi; Hirosawa, Shota; Oguchi, Yusuke; Suzuki, Madoka; Murata, Atsushi; Ishiwata, Shin'ichi; Takeoka, Shinji
2012-08-13
This paper describes a convenient screening method using ion trap electrospray ionization mass spectrometry to classify ligands to a target molecule in terms of kinetic parameters. We demonstrate this method in the screening of ligands to a hexahistidine tag from a pooled library synthesized by click chemistry. The ion trap mass spectrometry analysis revealed that higher stabilities of ligand-target complexes in the gas phase were related to lower dissociation rate constants, i.e., off-rates in solution. Finally, we prepared a fluorescent probe utilizing the ligand with lowest off-rate and succeeded in performing single molecule observations of hexahistidine-tagged myosin V walking on actin filaments.
Role of capillary electrophoresis in the fight against doping in sports.
Harrison, Christopher R
2013-08-06
At present the role of capillary electrophoresis in the detection of doping agents in athletes is, for the most part, nonexistent. More traditional techniques, namely gas and liquid chromatography with mass spectrometric detection, remain the gold standard of antidoping tests. This Feature will investigate the in-roads that capillary electrophoresis has made, the limitations that the technique suffers from, and where the technique may grow into being a key tool for antidoping analysis.
Dahl, Jeffrey H; van Breemen, Richard B
2010-09-15
A rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed for the measurement of urinary 8-iso-prostaglandin F(2alpha) (8-iso-PGF(2alpha)), a biomarker of lipid peroxidation. Because urine contains numerous F(2) prostaglandin isomers, each with identical mass and similar mass spectrometric fragmentation patterns, chromatographic separation of 8-iso-PGF(2alpha) from its isomers is necessary for its quantitative analysis using MS/MS. We were able to achieve this separation using an isocratic LC method with a run time of less than 9min, which is at least threefold faster than previous methods, while maintaining sensitivity, accuracy, precision, and reliability. The limits of detection and quantitation were 53 and 178pg/ml urine, respectively. We compared our method with a commercially available affinity purification and enzyme immunoassay kit and found both assays to be in agreement. Despite the high sensitivity of the enzyme immunoassay method, it is more expensive and has a narrower dynamic range than LC-MS/MS. Our method was optimized for rapid measurement of 8-iso-PGF(2alpha) in urine, and it is ideally suited for clinical sample analysis. 2010 Elsevier Inc. All rights reserved.
Liang, Weiqian; Wang, Juntao; Zang, Xiaohuan; Dong, Wenhuan; Wang, Chun; Wang, Zhi
2017-03-31
In this work, a barley husk biomaterial was successfully carbonized by hydrothermal method. The carbon had a high specific surface area and good stability. It was coated onto a stainless steel wire through sol-gel technique to prepare a solid-phase microextraction fiber for the extraction of trace levels of twelve pesticides (tsumacide, fenobucarb, indoxacarb, diethofencarb, thimet, terbufos, malathion, thiamethoxam, imidacloprid, buprofezin, acetamiprid, thiamethoxam) from vegetable samples prior to gas chromatography-mass spectrometric (GC-MS) detection. The main experimental parameters that could influence the extraction efficiency such as extraction time, extraction temperature, sample pH, sample salinity, stirring rate, desorption temperature and desorption time, were investigated. Under the optimized conditions, the linearity was observed in the range of 0.2-75.0μgkg -1 for tomato samples, and 0.3-60.0μgkg -1 for cucumber samples, with the correlation coefficients (r) ranging from 0.9959 to 0.9983. The limits of detection of the method were 0.01-0.05μgkg -1 for tomato samples, and 0.03-0.10μgkg -1 for cucumber samples. The recoveries of the analytes for the method from spiked samples were in the range of 76%-104%, and the precision, expressed as the relative standard deviations, was less than 12%. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Loftin, Kathleen; Griffin, Timothy; Captain, Janine
2013-01-01
The Resource Prospector is a mission to prospect for lunar volatiles (primarily water) at one of the two lunar poles, as well as demonstrate In-Situ Resource Utilization (ISRU) on the Moon. The Resource Prospector consists of a lander, a rover, and a rover-borne scientific payload. The Regolith and Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) payload, will be able to (1) locate near subsurface volatiles, (2) excavate and analyze samples of the volatile-bearing regolith, and (3) demonstrate the form, extractability and usefulness of the materials. The gas chromatograph mass spectrometer (GCMS) is the primary instrument in the RESOLVE instrumentation suite responsible for identification and quantification of the volatiles evolved from the lunar regolith. Specifically, this instrument must have: a low mass, a low power consumption, be able to perform fast analyses of samples ranging from less than one to greater than ninety nine percent water by mass, be autonomously controlled by the payload's software and avionics platform, and be able to operate in the harsh lunar environment. The RPM's short mission duration is the primary driver of the requirement for a very fast analysis time currently base lined at less than 2 minutes per sample. This presentation will discuss the requirements levied upon the GCMS design, lessons learned from a preliminary field demonstration deployment, the current design, and the path forward.
Used tire recycling to produce granulates: evaluation of occupational exposure to chemical agents.
Savary, Barbara; Vincent, Raymond
2011-10-01
Exposure was assessed in four facilities where used tires are turned into rubber granulates. Particulate exposure levels were measured using filter samples and gravimetric analysis. In parallel, volatile organic compounds (VOCs) screening was carried out using samples taken on activated carbon supports, followed by an analysis using a gas chromatograph coupled to a spectrometric detector. The exposure level medians are between 0.58 and 3.95 mg m(-3). Clogging of the textile fiber separation systems can lead to worker exposure; in this case, the measured concentrations can reach 41 mg m(-3). However, in contrast to the data in the literature, VOC levels >1 p.p.m. were not detected. The particulate mixtures deposited on the installation surfaces are complex; some of the chemical agents are toxic to humans. The results of this study indicate significant exposure to complex mixtures of rubber dust. Optimizing exhaust ventilation systems inside the shredders, with a cyclone for example, is essential for reducing the exposure of workers in this rapidly developing sector.
A low Earth orbit molecular beam space simulation facility
NASA Technical Reports Server (NTRS)
Cross, J. B.
1984-01-01
A brief synopsis of the low Earth orbit (LEO) satellite environment is presented including neutral and ionic species. Two ground based atomic and molecular beam instruments are described which are capable of simulating the interaction of spacecraft surfaces with the LEO environment and detecting the results of these interactions. The first detects mass spectrometrically low level fluxes of reactively and nonreactively surface scattered species as a function of scattering angle and velocity while the second ultrahigh velocity (UHV) molecular beam, laser induced fluorescence apparatus is capable of measuring chemiluminescence produced by either gas phase or gas-surface interactions. A number of proposed experiments are described.
2005-02-01
followed by extensive sample preparation procedures that are performed in a laboratory. Analysis is typically conducted by injecting a liquid or gas sample...Alfentanil, Remifentanil , Sufentanil, and Carfentanil) in a laboratory. (5) Quantitatively determine a maximum temperature ramping rate at which the LTM...RHT Column combined with a GC-MS can separate and analyze a mixture of non- traditional CWAs (i.e. Fentanyl, Alfentanil, Remifentanil , Sufentanil
Chen, Pei; Atkinson, Renata; Wolf, Wayne R
2009-01-01
The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 microm, 250 x 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLDIMS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.
Chen, Pei; Atkinson, Renata; Wolf, Wayne R.
2014-01-01
The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 µm, 250 × 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLD/MS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration. PMID:19485230
Zhang, Yaping; Williams, Brent J.; Goldstein, Allen H.; ...
2016-11-25
Here, we present a rapid method for apportioning the sources of atmospheric organic aerosol composition measured by gas chromatography–mass spectrometry methods. Here, we specifically apply this new analysis method to data acquired on a thermal desorption aerosol gas chromatograph (TAG) system. Gas chromatograms are divided by retention time into evenly spaced bins, within which the mass spectra are summed. A previous chromatogram binning method was introduced for the purpose of chromatogram structure deconvolution (e.g., major compound classes) (Zhang et al., 2014). Here we extend the method development for the specific purpose of determining aerosol samples' sources. Chromatogram bins are arrangedmore » into an input data matrix for positive matrix factorization (PMF), where the sample number is the row dimension and the mass-spectra-resolved eluting time intervals (bins) are the column dimension. Then two-dimensional PMF can effectively do three-dimensional factorization on the three-dimensional TAG mass spectra data. The retention time shift of the chromatogram is corrected by applying the median values of the different peaks' shifts. Bin width affects chemical resolution but does not affect PMF retrieval of the sources' time variations for low-factor solutions. A bin width smaller than the maximum retention shift among all samples requires retention time shift correction. A six-factor PMF comparison among aerosol mass spectrometry (AMS), TAG binning, and conventional TAG compound integration methods shows that the TAG binning method performs similarly to the integration method. However, the new binning method incorporates the entirety of the data set and requires significantly less pre-processing of the data than conventional single compound identification and integration. In addition, while a fraction of the most oxygenated aerosol does not elute through an underivatized TAG analysis, the TAG binning method does have the ability to achieve molecular level resolution on other bulk aerosol components commonly observed by the AMS.« less
NASA Astrophysics Data System (ADS)
Zhang, Yaping; Williams, Brent J.; Goldstein, Allen H.; Docherty, Kenneth S.; Jimenez, Jose L.
2016-11-01
We present a rapid method for apportioning the sources of atmospheric organic aerosol composition measured by gas chromatography-mass spectrometry methods. Here, we specifically apply this new analysis method to data acquired on a thermal desorption aerosol gas chromatograph (TAG) system. Gas chromatograms are divided by retention time into evenly spaced bins, within which the mass spectra are summed. A previous chromatogram binning method was introduced for the purpose of chromatogram structure deconvolution (e.g., major compound classes) (Zhang et al., 2014). Here we extend the method development for the specific purpose of determining aerosol samples' sources. Chromatogram bins are arranged into an input data matrix for positive matrix factorization (PMF), where the sample number is the row dimension and the mass-spectra-resolved eluting time intervals (bins) are the column dimension. Then two-dimensional PMF can effectively do three-dimensional factorization on the three-dimensional TAG mass spectra data. The retention time shift of the chromatogram is corrected by applying the median values of the different peaks' shifts. Bin width affects chemical resolution but does not affect PMF retrieval of the sources' time variations for low-factor solutions. A bin width smaller than the maximum retention shift among all samples requires retention time shift correction. A six-factor PMF comparison among aerosol mass spectrometry (AMS), TAG binning, and conventional TAG compound integration methods shows that the TAG binning method performs similarly to the integration method. However, the new binning method incorporates the entirety of the data set and requires significantly less pre-processing of the data than conventional single compound identification and integration. In addition, while a fraction of the most oxygenated aerosol does not elute through an underivatized TAG analysis, the TAG binning method does have the ability to achieve molecular level resolution on other bulk aerosol components commonly observed by the AMS.
NASA Technical Reports Server (NTRS)
1974-01-01
The charactertistics and performance capability of the current Viking '75 Gas Chromatograph/Mass Spectrometer Instrument are reviewed and documented for the purpose of possible integration with a wet chemistry instrument. Interface, high mass discrimination, and vacuum requirements were determined in a simulated flight investigation. Suggestions for future investigations, tradeoff studies, and design modifications are presented, along with the results of column bleed measurements. A preliminary design of an integrated Wet Chemistry/Mass Spectrometer instrument for amino acid analysis is shown, including estimates of additional weight, volume, and power requirements.
A fast sampling device for the mass spectrometric analysis of liquid rocket engine exhaust
NASA Technical Reports Server (NTRS)
Ryason, P. R.
1975-01-01
The design of a device to obtain compositional data on rocket exhaust by direct sampling of reactive flow exhausts into a mass spectrometer is presented. Sampling at three stages differing in pressure and orifice angle and diameter is possible. Results of calibration with pure gases and gas mixtures are erratic and of unknown accuracy for H2, limiting the usefulness of the apparatus for determining oxidizer/fuel ratios from combustion product analysis. Deposition effects are discussed, and data obtained from rocket exhaust spectra are analyzed to give O/F ratios and mixture ratio distribution. The O/F ratio determined spectrometrically is insufficiently accurate for quantitative comparison with cold flow data. However, a criterion for operating conditions with improved mixing of fuel and oxidizer which is consistent with cold flow results may be obtained by inspection of contour plots. A chemical inefficiency in the combustion process when oxidizer is in excess is observed from reactive flow measurements. Present results were obtained with N2O4/N2H4 propellants.
Since the initial discovery of polychlorinated biphenyls (PCBs) in the environment, the detection and identification of certain PCB congeners using the traditional one dimensional (1-D) chromatographic technique has been very challenging, especially, separating the 46 isomeric pe...
Andersson, Maria; Stephanson, Nikolai; Ohman, Inger; Terzuoli, Tommy; Lindh, Jonatan D; Beck, Olof
2014-04-01
Opiates comprise a class of abused drugs that is of primary interest in clinical and forensic urine drug testing. Determination of heroin, codeine, or a multi-drug ingestion is complicated since both heroin and codeine can lead to urinary excretion of free and conjugated morphine. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) offers advantage over gas chromatography-mass spectrometry by simplifying sample preparation but increases the number of analytes. A method based on direct injection of five-fold diluted urine for confirmation of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, codeine-6-glucuronide and 6-acetylmorphine was validated using LC-MS/MS in positive electrospray mode monitoring two transitions using selected reaction monitoring. The method was applied for the analysis of 3155 unknown urine samples which were positive for opiates in immunochemical screening. A linear response was observed for all compounds in the calibration curves covering more than three orders of magnitude. Cut off was set to 2 ng/ml for 6-acetylmorphine and 150 ng/ml for the other analytes. 6-Acetylmorphine was found to be effective (sensitivity 82%) in detecting samples as heroin intake. Morphine-3-glucuronide and codeine-6-glucuronide was the predominant components of total morphine and codeine, 84% and 93%, respectively. The authors have validated a robust LC-MS/MS method for rapid qualitative and quantitative analysis of opiates in urine. 6-Acetylmorphine has been demonstrated as a sensitive and important parameter for a heroin intake. A possible interpretation strategy to conclude the source of detected analytes was proposed. The method might be further developed by reducing the number of analytes to morphine-3-glucuronide, codeine-6-glucuronide and 6-acetylmorphine without compromising test performance. Copyright © 2013 John Wiley & Sons, Ltd.
Al-Dirbashi, Osama Y; Kölker, Stefan; Ng, Dione; Fisher, Lawrence; Rupar, Tony; Lepage, Nathalie; Rashed, Mohamed S; Santa, Tomofumi; Goodman, Stephen I; Geraghty, Michael T; Zschocke, Johannes; Christensen, Ernst; Hoffmann, Georg F; Chakraborty, Pranesh
2011-02-01
Accumulation of glutaric acid (GA) and 3-hydroxyglutaric acid (3HGA) in body fluids is the biochemical hallmark of type 1 glutaric aciduria (GA1), a disorder characterized by acute striatal degeneration and a subsequent dystonia. To date, methods for quantification of 3HGA are mainly based on stable isotope dilution gas chromatography mass spectrometry (GC-MS) and require extensive sample preparation. Here we describe a simple liquid chromatography tandem MS (LC-MS/MS) method to quantify this important metabolite in dried urine spots (DUS). This method is based on derivatization with 4-[2-(N,N-dimethylamino)ethylaminosulfonyl]-7-(2-aminoethylamino)-2,1,3-benzoxadiazole (DAABD-AE). Derivatization was adopted to improve the chromatographic and mass spectrometric properties of the studied analytes. Derivatization was performed directly on a 3.2-mm disc of DUS as a sample without extraction. Sample mixture was heated at 60°C for 45 min, and 5 μl of the reaction solution was analyzed by LC-MS/MS. Reference ranges obtained were in excellent agreement with the literature. The method was applied retrospectively for the analysis of DUS samples from established low- and high-excreter GA1 patients as well as controls (n = 100). Comparison of results obtained versus those obtained by GC-MS was satisfactory (n = 14). In populations with a high risk of GA1, this approach will be useful as a primary screening method for high- or low-excreter variants. In these populations, however, DUS analysis should not be implemented before completing a parallel comparative study with the standard screening method (i.e., molecular testing). In addition, follow-up DUS GA and 3HGA testing of babies with elevated dried blood spot C5DC acylcarnitines will be useful as a first-tier diagnostic test, thus reducing the number of cases requiring enzymatic and molecular analyses to establish or refute the diagnosis of GA1.
Fang, Jing; Wu, Qian; Zhao, Yun; Zhao, Hongzhi; Xu, Shunqing; Cai, Zongwei
2017-01-01
Gas chromatography-triple quadrupole mass spectrometry (GC-QqQMS) was applied for the determination of eight organochlorine pesticides (OCPs) in human serum. OCPs were extracted from the serum sample by solid phase extraction (SPE) and analyzed by gas chromatography mass spectrometry (GC-MS) or gas chromatography tandem mass spectrometry (GC-MS/MS). Electron ionization (EI) and negative chemical ionization (NCI) under two data acquisition modes, namely selected ion monitoring (SIM) and multiple reaction monitoring (MRM), were compared. The use of MRM generally provided higher selectivity and sensitivity because less interference from the sample matrix existed. The EI mode is more suitable for less electronegative compounds such as dichlorodiphenyldichloroethanes (DDDs) with detection limits ranging from 0.0060 to 0.060ng/mL. In the NCI mode, MRM analysis provided good and lower detection limits (0.0011-0.0030ng/mL) for pesticides containing more chlorines. The methods were validated by analyzing the pesticides in spiked serum at different levels with recoveries ranged from 83% to 116% and relative standard deviations of less than 10%. The developed method was applied for the determination of the OCPs in real human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Anion binding by bambus[6]uril probed in the gas phase and in solution.
Révész, Agnes; Schröder, Detlef; Svec, Jan; Wimmerová, Michaela; Sindelar, Vladimir
2011-10-20
Electrospray ionization mass spectrometry (ESI-MS) is used to probe the binding of small anions to the macrocycle of bambus[6]uril. For the halide ions, the experimental patterns suggest F(-) < Cl(-) < Br(-) < I(-), which is consistent with the order of anion binding found in the condensed phase. Parallel equilibrium studies in the condensed phase establish the association constants of halide anions and bambus[6]uril in mixed solvents. A detailed analysis of the mass spectrometric data is used to shed light on the correlations between the binding constants in the condensed phase and the ion abundances observed using ESI-MS. From the analysis it becomes apparent that ESI-MS can indeed represent the situation in solution to some extent, but the sampling in the gas-phase experiment is not 1:1 compared to that in solution.
Ding, Hui; Ding, Wanjing; Ma, Zhongjun
2017-01-01
Two prenylated indole alkaloids were isolated from the ethyl acetate extracts of a marine-derived fungus Penicillium sp. NH-SL and one of them exhibited potent cytotoxic activity against mouse hepa 1c1c7 cells. In order to detect other bioactive analogs, we used liquid chromatogram tandem mass spectrometry (LC-MS/MS) to analyze the mass spectrometric characteristics of the isolated compounds as well as the crude extracts. As a result, three other analogs were detected, and their structures were deduced according to the similar fragmentation patterns. This is the first systematic report on the mass spectrometric characteristics of prenylated indole derivatives. PMID:28327529
Valero, E; Sanz, J; Martínez-Castro, I
2001-06-01
Direct thermal desorption (DTD) has been used as a technique for extracting volatile components of cheese as a preliminary step to their gas chromatographic (GC) analysis. In this study, it is applied to different cheese varieties: Camembert, blue, Chaumes, and La Serena. Volatiles are also extracted using other techniques such as simultaneous distillation-extraction and dynamic headspace. Separation and identification of the cheese components are carried out by GC-mass spectrometry. Approximately 100 compounds are detected in the examined cheeses. The described results show that DTD is fast, simple, and easy to automate; requires only a small amount of sample (approximately 50 mg); and affords quantitative information about the main groups of compounds present in cheeses.
Hofmann, Tamás; Nebehaj, Esztella; Albert, Levente
2015-05-08
The aim of the present work was the high-performance liquid chromatographic separation and multistage mass spectrometric characterization of the polyphenolic compounds of beech bark, as well as the extraction optimization of the identified compounds. Beech is a common and widely used material in the wood industry, yet its bark is regarded as a by-product. Using appropriate extraction methods these compounds could be extracted and utilized in the future. Different extraction methods (stirring, sonication, microwave assisted extraction) using different solvents (water, methanol:water 80:20 v/v, ethanol:water 80:20 v/v) and time/temperature schedules have been compared basing on total phenol contents (Folin-Ciocâlteu) and MRM peak areas of the identified compounds to investigate optimum extraction efficiency. Altogether 37 compounds, including (+)-catechin, (-)-epicatechin, quercetin-O-hexoside, taxifolin-O-hexosides (3), taxifolin-O-pentosides (4), B-type (6) and C-type (6) procyanidins, syringic acid- and coumaric acid-di-O-glycosides, coniferyl alcohol- and sinapyl alcohol-glycosides, as well as other unknown compounds with defined [M-H](-) m/z values and MS/MS spectra have been tentatively identified. The choice of the method, solvent system and time/temperature parameters favors the extraction of different types of compounds. Pure water can extract compounds as efficiently as mixtures containing organic solvents under high-pressure and high temperature conditions. This supports the implementation of green extraction methods in the future. Extraction times that are too long and high temperatures can result in the decrease of the concentrations. Future investigations will focus on the evaluation of the antioxidant capacity and utilization possibilities of the prepared extracts. Copyright © 2015 Elsevier B.V. All rights reserved.
Shou, Wilson Z; Naidong, Weng
2003-01-01
It has become increasingly popular in drug development to conduct discovery pharmacokinetic (PK) studies in order to evaluate important PK parameters of new chemical entities (NCEs) early in the discovery process. In these studies, dosing vehicles are typically employed in high concentrations to dissolve the test compounds in dose formulations. This can pose significant problems for the liquid chromatography/tandem mass spectrometric (LC/MS/MS) analysis of incurred samples due to potential signal suppression of the analytes caused by the vehicles. In this paper, model test compounds in rat plasma were analyzed using a generic fast gradient LC/MS/MS method. Commonly used dosing vehicles, including poly(ethylene glycol) 400 (PEG 400), polysorbate 80 (Tween 80), hydroxypropyl beta-cyclodextrin, and N,N-dimethylacetamide, were fortified into rat plasma at 5 mg/mL before extraction. Their effects on the sample analysis results were evaluated by the method of post-column infusion. Results thus obtained indicated that polymeric vehicles such as PEG 400 and Tween 80 caused significant suppression (> 50%, compared with results obtained from plasma samples free from vehicles) to certain analytes, when minimum sample cleanup was used and the analytes happened to co-elute with the vehicles. Effective means to minimize this 'dosing vehicle effect' included better chromatographic separations, better sample cleanup, and alternative ionization methods. Finally, a real-world example is given to illustrate the suppression problem posed by high levels of PEG 400 in sample analysis, and to discuss steps taken in overcoming the problem. A simple but effective means of identifying a 'dosing vehicle effect' is also proposed. Copyright 2003 John Wiley & Sons, Ltd.
2012-01-01
Background Establishing the distribution of materials in paintings and that of their degradation products by imaging techniques is fundamental to understand the painting technique and can improve our knowledge on the conservation status of the painting. The combined use of chromatographic-mass spectrometric techniques, such as GC/MS or Py/GC/MS, and the chemical mapping of functional groups by imaging SR FTIR in transmission mode on thin sections and SR XRD line scans will be presented as a suitable approach to have a detailed characterisation of the materials in a paint sample, assuring their localisation in the sample build-up. This analytical approach has been used to study samples from Catalan paintings by Josep Maria Sert y Badía (20th century), a muralist achieving international recognition whose canvases adorned international buildings. Results The pigments used by the painter as well as the organic materials used as binders and varnishes could be identified by means of conventional techniques. The distribution of these materials by means of Synchrotron Radiation based techniques allowed to establish the mixtures used by the painter depending on the purpose. Conclusions Results show the suitability of the combined use of SR μFTIR and SR μXRD mapping and conventional techniques to unequivocally identify all the materials present in the sample and their localization in the sample build-up. This kind of approach becomes indispensable to solve the challenge of micro heterogeneous samples. The complementary interpretation of the data obtained with all the different techniques allowed the characterization of both organic and inorganic materials in the samples layer by layer as well as to establish the painting techniques used by Sert in the works-of-art under study. PMID:22616949
Research on technology of online gas chromatograph for SF6 decomposition products
NASA Astrophysics Data System (ADS)
Li, L.; Fan, X. P.; Zhou, Y. Y.; Tang, N.; Zou, Z. L.; Liu, M. Z.; Huang, G. J.
2017-12-01
Sulfur hexafluoride (SF6) decomposition products were qualitatively and quantitatively analyzed by several gas chromatographs in the laboratory. Test conditions and methods were selected and optimized to minimize and eliminate the SF6’ influences on detection of other trace components. The effective separation and detection of selected characteristic gases were achieved. And by comparison among different types of gas chromatograph, it was found that GPTR-S101 can effectively separate and detect SF6 decomposition products and has best the best detection limit and sensitivity. On the basis of GPTR-S101, online gas chromatograph for SF6decomposition products (GPTR-S201) was developed. It lays the foundation for further online monitoring and diagnosis of SF6.
Quéméner, Bernard; Désiré, Cédric; Lahaye, Marc; Debrauwer, Laurent; Negroni, Luc
2003-01-01
The off-line coupling of high-performance anion-exchange chromatography (HPAEC) to electrospray ionisation/ion trap mass spectrometry (ESI-ITMS) is described. The Dionex carbohydrate membrane desalter (CMD) has been assessed as an on-line chromatographic desalting system to remove the high sodium concentration necessary for the HPAEC separation of partially methyl-esterified oligogalacturonides. The developed HPAEC configuration proved to be suitable for indirect coupling with ESI-ITMS. This paper provides some interesting features of positive- and negative-ion multistage tandem mass spectrometry (MS(n)) analysis of these acidic oligosaccharides. The spectra acquired in both negative- and positive-ion modes show characteristic fragment ions resulting from glycosidic bond and cross-ring cleavages. Some new mass spectrometric fragmentation routes are also described. The positive-ion mode gave more complex spectra but was as informative as the negative-ion mode. ESI-ITMS was revealed to be, as previously reported from direct use on an unseparated enzymatic digest, a powerful sequencing technique for the determination of linkage type and the methyl ester distribution of partially methyl-esterified oligogalacturonides. Moreover, unlike matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-ToF MS), it gives valuable information on the elution behaviour of these oligomers in relation to their structure, namely the HPAEC co-elution of isomeric structures.
Krynitsky, A.J.; Stafford, C.J.; Wiemeyer, Stanley N.
1988-01-01
Dicofol in avian eggs was completely oxidized to dichlorobenzophenone (DCBP) when a hexane Soxhlet extraction procedure was used. This degradation did not occur with other avian tissues (muscle and liver). For this reason, a combined extraction-cleanup column chromatographic procedure, without added heat, was developed for the determination of dicofol in avian eggs. Homogenized subsamples of eggs were mixed with sodium sulfate, and the mixture was added as the top layer on a column prepacked with Florisil. The dicofol and other compounds of interest were then eluted with ethyl ether-hexane. The extracts, relatively free from lipids, were quantitated on a gas chromatograph equipped with a 63Ni electron-capture detector and a methyl silicone capillary column. Recoveries from chicken eggs, fortified with dicofol and other DDT-related compounds, averaged 96%. Analysis of eggs of eastern screech-owls, fed a meat diet containing 10 ppm technical Kelthane, showed that both dicofol and DCBP were present. Results were confirmed by gas chromatography/mass spectrometry. This method is rapid and reliable, involves a minimum of sample handling, and is well suited for high volume determination of dicofol in eggs and other avian tissues.