Science.gov

Sample records for gas chromatography cryofocusing

  1. Identification of volatile butyl rubber thermal-oxidative degradation products by cryofocusing gas chromatography/mass spectrometry (cryo-GC/MS).

    SciTech Connect

    Smith, Jonell Nicole; White, Michael Irvin; Bernstein, Robert; Hochrein, James Michael

    2013-02-01

    Chemical structure and physical properties of materials, such as polymers, can be altered as aging progresses, which may result in a material that is ineffective for its envisioned intent. Butyl rubber formulations, starting material, and additives were aged under thermal-oxidative conditions for up to 413 total days at up to 124 ÀC. Samples included: two formulations developed at Kansas City Plant (KCP) (#6 and #10), one commercially available formulation (#21), Laxness bromobutyl 2030 starting material, and two additives (polyethylene AC-617 and Vanax MBM). The low-molecular weight volatile thermal-oxidative degradation products that collected in the headspace over the samples were preconcentrated, separated, and detected using cryofocusing gas chromatography mass spectrometry (cryo-GC/MS). The majority of identified degradation species were alkanes, alkenes, alcohols, ketones, and aldehydes. Observations for Butyl #10 aged in an oxygen-18 enriched atmosphere (18O2) were used to verify when the source of oxygen in the applicable degradation products was from the gaseous environment rather than the polymeric mixture. For comparison purposes, Butyl #10 was also aged under non-oxidative thermal conditions using an argon atmosphere.

  2. Gas Chromatography.

    ERIC Educational Resources Information Center

    Karasek, Francis W.; And Others

    1984-01-01

    This review covers fundamental developments in gas chromatography during 1982 and 1983. Literature is considered under these headings: columns; liguid phases; solid supports; sorption processes and solvents; open tubular column gas chromatography; instrumentation; high-resolution columns and applications; other techniques; qualitative and…

  3. Gas Chromatography.

    ERIC Educational Resources Information Center

    Karasek, Francis W.; And Others

    1984-01-01

    This review covers fundamental developments in gas chromatography during 1982 and 1983. Literature is considered under these headings: columns; liguid phases; solid supports; sorption processes and solvents; open tubular column gas chromatography; instrumentation; high-resolution columns and applications; other techniques; qualitative and…

  4. Gas Chromatography.

    ERIC Educational Resources Information Center

    Cram, Stuart P.; And Others

    1980-01-01

    Selects fundamental developments in theory, methodology, and instrumentation in gas chromatography (GC). A special section reviews GC in the People's Republic of China. Over 1,000 references are cited. (CS)

  5. Gas Chromatography.

    ERIC Educational Resources Information Center

    Cram, Stuart P.; And Others

    1980-01-01

    Selects fundamental developments in theory, methodology, and instrumentation in gas chromatography (GC). A special section reviews GC in the People's Republic of China. Over 1,000 references are cited. (CS)

  6. Gas chromatography.

    PubMed

    Eiceman, G A; Hill, H H; Gardea-Torresdey, J

    1998-06-15

    This review of the fundamental developments in gas chromatography (GC) includes articles published from 1996 and 1997 and an occasional citation prior to 1996. The literature was reviewed principally using CA Selects for Gas Chromatography from Chemical Abstracts Service, and some significant articles from late 1997 may be missing from the review. In addition, the online SciSearch Database (Institute for Scientific Information) capability was used to abstract review articles or books. As with the prior recent reviews, emphasis has been given to the identification and discussion of selected developments, rather than a presentation of a comprehensive literature search, now available widely through computer-based resources. During the last two years, several themes emerged from a review of the literature. Multidimensional gas chromatography has undergone transformation encompassing a broad range of activity, including attempts to establish methods using chromatographic principles rather than a totally empirical approach. Another trend noted was a comparatively large effort in chromatographic theory through modeling efforts; these presumably became resurgent with inexpensive and powerful computing tools. Finally, an impressive level of activity was noted through the themes highlighted in this review, and this was particularly true with detectors and field instruments.

  7. Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Qian, Michael C.

    Gas chromatography (GC) has many applications in the analysis of food products. GC has been used for the determination of fatty acids, triglycerides, cholesterol, gases, water, alcohols, pesticides, flavor compounds, and many more. While GC has been used for other food components such as sugars, oligosaccharides, amino acids, peptides, and vitamins, these substances are more suited to analysis by high performance liquid chromatography. GC is ideally suited to the analysis of volatile substances that are thermally stable. Substances such as pesticides and flavor compounds that meet these criteria can be isolated from a food and directly injected into the GC. For compounds that are thermally unstable, too low in volatility, or yield poor chromatographic separation due to polarity, a derivatization step must be done before GC analysis. The two parts of the experiment described here include the analysis of alcohols that requires no derivatization step, and the analysis of fatty acids which requires derivatization. The experiments specify the use of capillary columns, but the first experiment includes conditions for a packed column.

  8. Gas chromatography in space

    NASA Technical Reports Server (NTRS)

    Akapo, S. O.; Dimandja, J. M.; Kojiro, D. R.; Valentin, J. R.; Carle, G. C.

    1999-01-01

    Gas chromatography has proven to be a very useful analytical technique for in situ analysis of extraterrestrial environments as demonstrated by its successful operation on spacecraft missions to Mars and Venus. The technique is also one of the six scientific instruments aboard the Huygens probe to explore Titan's atmosphere and surface. A review of gas chromatography in previous space missions and some recent developments in the current environment of fiscal constraints and payload size limitations are presented.

  9. Determination of benzene residues in recycled polyethylene terephthalate (PETE) by dynamic headspace-gas chromatography.

    PubMed

    Komolprasert, V; Hargraves, W A; Armstrong, D J

    1994-01-01

    A dynamic headspace-gas chromatography (HS/GC) method was developed to quantitate benzene in recycled PETE material derived from 21 PETE beverage bottles. The analytical system consisted of a purge-and-trap apparatus which was interfaced directly with a gas chromatograph/flame ionization detector. Cryofocusing and non-cryofocusing GC systems were used. The technique was applied to spiked PETE test samples which were prepared at various benzene concentrations ranging from 100 ppb to 117 ppm. The initial spiked benzene concentration in the PETE test samples was determined gravimetrically. The HS/GC technique was limited by the slow desorption rate of benzene from the PETE matrix; as a result, multipurges were performed at 60 degrees C. Regression analysis was done on the multipurge data to develop a desorption model which would predict the total amount of benzene in the PETE. The calculated results agreed with the experimental recoveries within +/- 10%. Recovery depended on the initial benzene level in the PETE and ranged from 70 to 90% after the first five purges.

  10. Multiplex gas chromatography

    NASA Technical Reports Server (NTRS)

    Valentin, Jose R.

    1990-01-01

    The principles of the multiplex gas chromatography (GC) technique, which is a possible candidate for chemical analysis of planetary atmospheres, are discussed. Particular attention is given to the chemical modulators developed by present investigators for multiplex GC, namely, the thermal-desorption, thermal-decomposition, and catalytic modulators, as well as to mechanical modulators. The basic technique of multiplex GC using chemical modulators and a mechanical modulator is demonstrated. It is shown that, with the chemical modulators, only one gas stream consisting of the carrier in combination with the components is being analyzed, resulting in a simplified instrument that requires relatively few consumables. The mechanical modulator demonstrated a direct application of multiplex GC for the analysis of gases in atmosphere of Titan at very low pressures.

  11. Multiplex gas chromatography

    NASA Technical Reports Server (NTRS)

    Valentin, Jose R.

    1990-01-01

    The principles of the multiplex gas chromatography (GC) technique, which is a possible candidate for chemical analysis of planetary atmospheres, are discussed. Particular attention is given to the chemical modulators developed by present investigators for multiplex GC, namely, the thermal-desorption, thermal-decomposition, and catalytic modulators, as well as to mechanical modulators. The basic technique of multiplex GC using chemical modulators and a mechanical modulator is demonstrated. It is shown that, with the chemical modulators, only one gas stream consisting of the carrier in combination with the components is being analyzed, resulting in a simplified instrument that requires relatively few consumables. The mechanical modulator demonstrated a direct application of multiplex GC for the analysis of gases in atmosphere of Titan at very low pressures.

  12. Capillary gas-solid chromatography

    NASA Astrophysics Data System (ADS)

    Berezkin, Viktor G.

    1996-11-01

    The current state of gas adsorption chromatography on open tubular capillary columns is analysed. The history of the development of this method and its role in gas chromatography are considered. The preparation of open tubular adsorption capillary columns, fundamentals of the theory of retention and of broadening of chromatographic zones, and the use of columns of this type in practical analytical chemistry are discussed. The bibliography includes 148 references.

  13. Automated gas chromatography

    DOEpatents

    Mowry, Curtis D.; Blair, Dianna S.; Rodacy, Philip J.; Reber, Stephen D.

    1999-01-01

    An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute.

  14. Thermal modulation for gas chromatography

    NASA Technical Reports Server (NTRS)

    Hasselbrink, Ernest F. (Inventor); Libardoni, Mark (Inventor); Stewart, Kristine (Inventor); Waite, J. Hunter (Inventor); Block, Bruce P. (Inventor); Sacks, Richard D. (Inventor)

    2007-01-01

    A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary.

  15. Thermal modulation for gas chromatography

    NASA Technical Reports Server (NTRS)

    Hasselbrink, Ernest F. (Inventor); Libardoni, Mark (Inventor); Stewart, Kristine (Inventor); Waite, J. Hunter (Inventor); Block, Bruce P. (Inventor); Sacks, Richard D. (Inventor)

    2007-01-01

    A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a recirculating fluid cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary. The capillary can include more than one separate thermally modulated sections.

  16. Automated gas chromatography

    DOEpatents

    Mowry, C.D.; Blair, D.S.; Rodacy, P.J.; Reber, S.D.

    1999-07-13

    An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute. 7 figs.

  17. A versatile, refrigerant- and cryogen-free cryofocusing-thermodesorption unit for preconcentration of traces gases in air

    NASA Astrophysics Data System (ADS)

    Obersteiner, Florian; Bönisch, Harald; Keber, Timo; O'Doherty, Simon; Engel, Andreas

    2016-10-01

    We present a compact and versatile cryofocusing-thermodesorption unit, which we developed for quantitative analysis of halogenated trace gases in ambient air. Possible applications include aircraft-based in situ measurements, in situ monitoring and laboratory operation for the analysis of flask samples. Analytes are trapped on adsorptive material cooled by a Stirling cooler to low temperatures (e.g. -80 °C) and subsequently desorbed by rapid heating of the adsorptive material (e.g. +200 °C). The set-up involves neither the exchange of adsorption tubes nor any further condensation or refocusing steps. No moving parts are used that would require vacuum insulation. This allows for a simple and robust design. Reliable operation is ensured by the Stirling cooler, which neither contains a liquid refrigerant nor requires refilling a cryogen. At the same time, it allows for significantly lower adsorption temperatures compared to commonly used Peltier elements. We use gas chromatography - mass spectrometry (GC-MS) for separation and detection of the preconcentrated analytes after splitless injection. A substance boiling point range of approximately -80 to +150 °C and a substance mixing ratio range of less than 1 ppt (pmol mol-1) to more than 500 ppt in preconcentrated sample volumes of 0.1 to 10 L of ambient air is covered, depending on the application and its analytical demands. We present the instrumental design of the preconcentration unit and demonstrate capabilities and performance through the examination of analyte breakthrough during adsorption, repeatability of desorption and analyte residues in blank tests. Examples of application are taken from the analysis of flask samples collected at Mace Head Atmospheric Research Station in Ireland using our laboratory GC-MS instruments and by data obtained during a research flight with our in situ aircraft instrument GhOST-MS (Gas chromatograph for the Observation of Tracers - coupled with a Mass Spectrometer).

  18. Multielement detector for gas chromatography

    SciTech Connect

    Sklarew, D.S.; Evans, J.C.; Olsen, K.B.

    1988-11-01

    This report describes the results of a study to improve the capabilities of a gas chromatography-microwave-induced plasma (GC- MIP) detector system, determine the feasibility of empirical formula determination for simple mixtures containing elements of interest to fossil fuel analysis and, subsequently, explore applications for analysis of the complex mixtures associated with fossil fuels. The results of this study indicate that the GC-MIP system is useful as a specific-element detector that provides excellent elemental specificity for a number of elements of interest to the analysis of fossil fuels. It has reasonably good sensitivity for carbon, hydrogen, sulfur, and nickel, and better sensitivity for chlorine and fluorine. Sensitivity is poor for nitrogen and oxygen, however, probably because of undetected leaks or erosion of the plasma tube. The GC-MIP can also provide stoichiometric information about components of simple mixtures. If this powerful technique is to be available for complex mixtures, it will be necessary to greatly simplify the chromatograms by chemical fractionation. 38 refs., 46 figs., 16 tabs.

  19. Dynamic thermal gradient gas chromatography.

    PubMed

    Contreras, Jesse A; Wang, Anzi; Rockwood, Alan L; Tolley, H Dennis; Lee, Milton L

    2013-08-09

    The use of negative axial thermal gradients in gas chromatography (TGGC) has intrigued chromatographers since the early 1950s because of the dramatic narrowing of analyte bands and concomitant raised expectations for improving resolving power. However, technical difficulties experienced in construction of TGGC instrumentation and control of the temperature along the column have made its implementation and, hence, detailed study difficult. In this work, we describe a TGGC system capable of rapidly producing and varying thermal gradient profiles by simultaneous use of resistive heating and convective cooling. Heating and cooling rates as high as 1200 and 2500°C/min, respectively, allowed the creation of dynamic temperature gradients. The separation characteristics of TGGC with dynamically changing temperature gradients are demonstrated. A gradient velocity of 2.22cm/s provided repetitive separations every 45s, and injection band widths of 45s duration were transformed into approximately 1-s peak widths. Peak tailing for basic compounds was nearly eliminated. Dynamic TGGC allows unique control over separations, oftentimes improving resolution and detection signal-to-noise. Thermally controlled elution in TGGC holds great promise for performing smart separations in which the separation time window is most efficiently utilized, and optimized separations can be quickly achieved. Rapid adjustment of relative compound elution can be used to greatly reduce GC method development time. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Gas amplified ionization detector for gas chromatography

    DOEpatents

    Huston, Gregg C.

    1992-01-01

    A gas-amplified ionization detector for gas chromatrography which possesses increased sensitivity and a very fast response time. Solutes eluding from a gas chromatographic column are ionized by UV photoionization of matter eluting therefrom. The detector is capable of generating easily measured voltage signals by gas amplification/multiplication of electron products resulting from the UV photoionization of at least a portion of each solute passing through the detector.

  1. Triple sorbent thermal desorption/gas chromatography/mass spectrometry determination of vapor phase organic contaminants

    SciTech Connect

    Ma, C.Y.; Skeen, J.T.; Dindal, A.B.; Higgins, C.E.; Jenkins, R.A.

    1994-05-01

    A thermal desorption/ps chromatography/mass spectrometry (TD/GC/MS) has been evaluated for the determination of volatile organic compounds (VOCS) in vapor phase samples using Carbosieve S-III/Carbotrap/Carotrap C triple sorbent traps (TST) similar to those available from a commercial source. The analysis was carried out with a Hewlett-Packard 5985A or 5995 GC/MS system with a modified injector to adapt an inhouse manufactured short-path desorber for transferring desorbate directly onto a cryofocusing loop for subsequent GC/MS analysis. Vapor phase standards generated from twenty six compounds were used for method validation, including alkanes, alkyl alcohols, alkyl ketones, and alkyl nitrites, a group of representative compounds that have previously been identified in a target airborne matrix. The method was validated based on the satisfactory results in terms of reproducibility, recovery rate, stability, and linearity. A relative, standard deviation of 0.55 to 24.3 % was obtained for the entire TD process (generation of gas phase standards, spiking the standards on and desorbing from TST) over a concentration range of 20 to 500 ng/trap. Linear correlation coefficients for the calibration curves as determined ranged from 0.81 to 0.99 and limits of detection ranged from 3 to 76 ng. For a majority of standards, recoveries of greater than 90% were observed. For three selected standards spiked on TSTS, minimal loss (10 to 22%) was observed after storing the spiked in, a 4{degree}C refrigerator for 29 days. The only chromatographable artifact observed was a 5% conversion of isopropanol to acetone. The validated method been successfully applied, to the determination of VOCs collected from various emission sources in a diversified concentration range.

  2. Evaluation of injection methods for fast, high peak capacity separations with low thermal mass gas chromatography.

    PubMed

    Fitz, Brian D; Mannion, Brandyn C; To, Khang; Hoac, Trinh; Synovec, Robert E

    2015-05-01

    Low thermal mass gas chromatography (LTM-GC) was evaluated for rapid, high peak capacity separations with three injection methods: liquid, headspace solid phase micro-extraction (HS-SPME), and direct vapor. An Agilent LTM equipped with a short microbore capillary column was operated at a column heating rate of 250 °C/min to produce a 60s separation. Two sets of experiments were conducted in parallel to characterize the instrumental platform. First, the three injection methods were performed in conjunction with in-house built high-speed cryo-focusing injection (HSCFI) to cryogenically trap and re-inject the analytes onto the LTM-GC column in a narrower band. Next, the three injection methods were performed natively with LTM-GC. Using HSCFI, the peak capacity of a separation of 50 nl of a 73 component liquid test mixture was 270, which was 23% higher than without HSCFI. Similar peak capacity gains were obtained when using the HSCFI with HS-SPME (25%), and even greater with vapor injection (56%). For the 100 μl vapor sample injected without HSCFI, the preconcentration factor, defined as the ratio of the maximum concentration of the detected analyte peak relative to the analyte concentration injected with the syringe, was determined to be 11 for the earliest eluting peak (most volatile analyte). In contrast, the preconcentration factor for the earliest eluting peak using HSCFI was 103. Therefore, LTM-GC is demonstrated to natively provide in situ analyte trapping, although not to as great an extent as with HSCFI. We also report the use of LTM-GC applied with time-of-flight mass spectrometry (TOFMS) detection for rapid, high peak capacity separations from SPME sampled banana peel headspace.

  3. Temperature programmable microfabricated gas chromatography column

    DOEpatents

    Manginell, Ronald P.; Frye-Mason, Gregory C.

    2003-12-23

    A temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by the integration of a resistive heating element and temperature sensing on the microfabricated column. Additionally, means are provided to thermally isolate the heated column from their surroundings. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  4. Soil moisture by extraction and gas chromatography

    NASA Technical Reports Server (NTRS)

    Merek, E. L.; Carle, G. C.

    1973-01-01

    To determine moisture content of soils rapidly and conveniently extract moisture with methanol and determine water content of methanol extract by gas chromatography. Moisture content of sample is calculated from weight of water and methanol in aliquot and weight of methanol added to sample.

  5. Some recent developments in headspace gas chromatography

    Treesearch

    J.Y. Zhu; X.-S. Chai

    2005-01-01

    In this study, recent developments in headspace gas chromatography (HSGC) are briefly reviewed. Several novel HSGC techniques developed recently are presented in detail. These techniques were developed using the unique characteristics of the headspace sampling process implemented in commercial HSGC systems and therefore can be easily applied in laboratory and...

  6. Non-planar microfabricated gas chromatography column

    DOEpatents

    Lewis, Patrick R.; Wheeler, David R.

    2007-09-25

    A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.

  7. [Advances in micro gas chromatography].

    PubMed

    Guan, Yafeng; Wang, Jianwei; Duan, Chunfeng

    2009-09-01

    Miniaturization of analytical instruments has attracted great attentions both from scientists and industry because of their unique properties such as small volume, high performance, low power and material consumption. Gas chromatograph (GC) is one of the most widely used analytical instruments. Many efforts have been made to develop portable or micro GC for on-line, in-situ and fast analysis in field. In this review, the state of arts in the field of micro GC is summarized. The advances on micro GC including injectors, chromatographic separation columns and detectors are discussed separately. The applications of micro GC are also briefly reviewed. Finally, a prospect on the developments and applications of micro GC is outlined.

  8. Flow field thermal gradient gas chromatography.

    PubMed

    Boeker, Peter; Leppert, Jan

    2015-09-01

    Negative temperature gradients along the gas chromatographic separation column can maximize the separation capabilities for gas chromatography by peak focusing and also lead to lower elution temperatures. Unfortunately, so far a smooth thermal gradient over a several meters long separation column could only be realized by costly and complicated manual setups. Here we describe a simple, yet flexible method for the generation of negative thermal gradients using standard and easily exchangeable separation columns. The measurements made with a first prototype reveal promising new properties of the optimized separation process. The negative thermal gradient and the superposition of temperature programming result in a quasi-parallel separation of components each moving simultaneously near their lowered specific equilibrium temperatures through the column. Therefore, this gradient separation process is better suited for thermally labile molecules such as explosives and natural or aroma components. High-temperature GC methods also benefit from reduced elution temperatures. Even for short columns very high peak capacities can be obtained. In addition, the gradient separation is particularly beneficial for very fast separations below 1 min overall retention time. Very fast measurements of explosives prove the benefits of using negative thermal gradients. The new concept can greatly reduce the cycle time of high-resolution gas chromatography and can be integrated into hyphenated or comprehensive gas chromatography setups.

  9. Ionization-based detectors for gas chromatography.

    PubMed

    Poole, Colin F

    2015-11-20

    The gas phase ionization detectors are the most widely used detectors for gas chromatography. The column and makeup gases commonly used in gas chromatography are near perfect insulators. This facilitates the detection of a minute number of charge carriers facilitating the use of ionization mechanisms of low efficiency while providing high sensitivity. The main ionization mechanism discussed in this report are combustion in a hydrogen diffusion flame (flame ionization detector), surface ionization in a plasma (thermionic ionization detector), photon ionization (photoionization detector and pulsed discharge helium ionization detector), attachment of thermal electrons (electron-capture detector), and ionization by collision with metastable helium species (helium ionization detector). The design, response characteristics, response mechanism, and suitability for fast gas chromatography are the main features summarized in this report. Mass spectrometric detection and atomic emission detection, which could be considered as ionization detectors of a more sophisticated and complex design, are not discussed in this report. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Performance characteristics of cryofocusing GC/MS system at BWXT Pantex Plant.

    SciTech Connect

    Brown, Jason R.; Banet, Judith F.; Ithaca, Jerry (BWXT Pantex Plant, Amarillo, TX); Thornberg, Steven Michael; Woods, Lorelei

    2006-07-01

    Ensuring the reliability of all components within a weapon system becomes increasingly important as the stockpile ages. One of the most noteworthy surveillance techniques designed to circumvent (or take place alongside) traditional D&I operations is to collect a sample of gas from within the internal atmosphere of a particular region in a weapon. While a wealth of information about the weapon may be encoded within the composition of its gas sample, our access to that information is only as good as the method used to analyze the sample. It has been shown that cryofocusing-GC/MS offers advantages in terms of sensitivity, ease of sample collection, and robustness of the equipment/hardware used. Attention is therefore focused on qualifying a cryo-GC/MS system for routine stockpile surveillance operations at Pantex. A series of tests were performed on this instrument to characterize the linearity and repeatability of its response using two different standard gas mixes (ozone precursor and TO-14) at various concentrations. This paper outlines the methods used and the results of these tests in order to establish a baseline by which to compare future cryo-GC/MS analyses. A summary of the results is shown.

  11. Environmental analyses utilizing gas and liquid chromatography

    SciTech Connect

    Grob, R.L. )

    1993-01-01

    An overview of the various methods of analysis, in environmental studies, which utilizes gas chromatography (GC), liquid chromatography (HPLC), and ion chromatography (IC) is presented. In many cases the samples must be prepared for final measurement by employing other analytical techniques; eg., extraction (liquid-liquid, both micro and macro scale; solid-phase (SPE); supercritical fluid (SFE); headspace equilibration (HSGE); etc.). Details of the various methods will not be given but descriptive explanations and pertinent references will be furnished. Theoretical aspects of the various techniques will be referenced adequately for those not familiar with the methodologies. Since most of these methods are validated by the US Environmental Protection Agency (USEPA) addresses where the methods may be obtained will also be given.

  12. Improved Thermal Modulator for Gas Chromatography

    NASA Technical Reports Server (NTRS)

    Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.

    2008-01-01

    An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

  13. Evolved gas composition monitoring by repetitive injection gas chromatography.

    PubMed

    White, Robert L

    2015-11-20

    Performance characteristics and applications of a small volume gas chromatograph oven are described. Heating and cooling properties of the apparatus are evaluated and examples are given illustrating the advantages of greatly reducing the air bath volume surrounding fused silica columns. Fast heating and cooling of the oven permit it to be employed for repetitive injection analyses. By using fast gas chromatography separations to achieve short assay cycle times, the apparatus can be employed for on-line species-specific gas stream composition monitoring when volatile species concentrations vary on time scales of a few minutes or longer. This capability facilitates repeated sampling and fast gas chromatographic separations of volatile product mixtures produced during thermal analyses. Applications of repetitive injection gas chromatography-mass spectrometry evolved gas analyses to monitoring purge gas effluent streams containing volatile acid catalyzed polymer cracking products are described. The influence of thermal analysis and chromatographic experimental parameters on effluent sampling frequency are delineated. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Permanent gas analysis using gas chromatography with vacuum ultraviolet detection.

    PubMed

    Bai, Ling; Smuts, Jonathan; Walsh, Phillip; Fan, Hui; Hildenbrand, Zacariah; Wong, Derek; Wetz, David; Schug, Kevin A

    2015-04-03

    The analysis of complex mixtures of permanent gases consisting of low molecular weight hydrocarbons, inert gases, and toxic species plays an increasingly important role in today's economy. A new gas chromatography detector based on vacuum ultraviolet (VUV) spectroscopy (GC-VUV), which simultaneously collects full scan (115-240 nm) VUV and UV absorption of eluting analytes, was applied to analyze mixtures of permanent gases. Sample mixtures ranged from off-gassing of decomposing Li-ion and Li-metal batteries to natural gas samples and water samples taken from private wells in close proximity to unconventional natural gas extraction. Gas chromatography separations were performed with a porous layer open tubular column. Components such as C1-C5 linear and branched hydrocarbons, water, oxygen, and nitrogen were separated and detected in natural gas and the headspace of natural gas-contaminated water samples. Of interest for the transport of lithium batteries were the detection of flammable and toxic gases, such as methane, ethylene, chloromethane, dimethyl ether, 1,3-butadiene, CS2, and methylproprionate, among others. Featured is the capability for deconvolution of co-eluting signals from different analytes. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Axial thermal gradients in microchip gas chromatography.

    PubMed

    Wang, Anzi; Hynynen, Sampo; Hawkins, Aaron R; Tolley, Samuel E; Tolley, H Dennis; Lee, Milton L

    2014-12-29

    Fabrication technologies for microelectromechanical systems (MEMS) allow miniaturization of conventional benchtop gas chromatography (GC) to portable, palm-sized microfabricated GC (μGC) devices, which are suitable for on-site chemical analysis and remote sensing. The separation performance of μGC systems, however, has not been on par with conventional GC. Column efficiency, peak symmetry and resolution are often compromised by column defects and non-ideal injections. The relatively low performance of μGC devices has impeded their further commercialization and broader application. In this work, the separation performance of μGC columns was improved by incorporating thermal gradient gas chromatography (TGGC). The analysis time was ∼20% shorter for TGGC separations compared to conventional temperature-programmed GC (TPGC) when a wide sample band was introduced into the column. Up to 50% reduction in peak tailing was observed for polar analytes, which improved their resolution. The signal-to-noise ratios (S/N) of late-eluting peaks were increased by 3-4 fold. The unique focusing effect of TGGC overcomes many of the previous shortcomings inherent in μGC analyses. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Targeted multidimensional gas chromatography using a heart-cutting device and cryogenic focusing for the determination of benzophenone derivatives in foodstuffs.

    PubMed

    Bugey, Aurélie; Janin, Yves; Edder, Patrick; Bieri, Stefan

    2013-05-01

    Photoinitiators are used to promote the polymerization process during the curing of varnishes or inks on cartonboard packaging. Depending on storage conditions and shelf life, these substances are able to migrate through the packaging layer into the foodstuff. This type of contamination phenomenon is therefore becoming a critical issue in terms of food safety. In order to tackle this problem, a fast and selective method was developed for the determination of benzophenone and three methylbenzophenone isomers in cereal-based foodstuffs and their cardboard packaging. Food samples or packages were efficiently extracted by pressurized liquid extraction using acetonitrile, and the extracts were directly injected onto the analytical system. The analysis was performed by multidimensional gas chromatography-mass spectrometry using a heart-cutting approach to reduce the background noise from complex matrices. The strategy employed two distinct cuts each containing its proper deuterated internal standard leading to accurate quantification. By integrating a cryofocusing effect, an enhancement in signal/noise ratio was achieved by a factor >10, which markedly decreased the sensitivity threshold. Moreover, baseline separation of the critical isomers allowed their unequivocal determination. The method was fully validated on cereal-based foodstuffs based upon an analysis of variance, and excellent performances were obtained at the decision limit making this method well suited for official food controls.

  17. Analysis of human skin emanations by gas chromatography/mass spectrometry. 2. Identification of volatile compounds that are candidate attractants for the yellow fever mosquito (Aedes aegypti).

    PubMed

    Bernier, U R; Kline, D L; Barnard, D R; Schreck, C E; Yost, R A

    2000-02-15

    Volatile compounds emanated from human skin were studied by gas chromatography/mass spectrometry (GC/MS). The purpose of this study was to identify compounds that may be human-produced kairomones which are used for host location by the mosquito, Aedes aegypti (L.). The procedure used to collect volatiles was chosen because of prior knowledge that attractive substances can be transferred from skin to glass by handling. Laboratory bioassays have shown that the residuum on the glass remains attractive to mosquitoes until the compounds of importance evaporate. The sampling and analytical procedures modeled the above-cited process as closely as possible except that the evaporation of compounds from the glass surface was accomplished by thermal desorption from glass beads in a heated GC injection port. This made possible the solventless injection of volatiles onto the column. The compounds were cryofocused on the head of the column with liquid nitrogen prior to GC separation. A single stage of mass spectrometry on a triple quadrupole instrument was used for mass analysis. A combination of electron ionization and pulsed positive ion/negative ion chemical ionization modes on two different GC columns (one polar, one relatively nonpolar) was used to identify most of the 346 compound peaks detected by this technique.

  18. Determination of Trace Polychlorinated Biphenyls and Organochlorine Pesticides in Water Samples through Large-Volume Stir Bar Sorptive Extraction Method with Thermal Desorption Gas Chromatography.

    PubMed

    Feng, Li; Zhang, Shengjun; Zhu, Guohua; Li, Mufei; Liu, Jinsong

    2017-10-06

    A fast and sensitive analytical method based on stir bar sorptive extraction technology with gas chromatography and mass spectrometry was developed to simultaneously analyse 18 kinds of polychlorinated biphenyls and 20 kinds of organochlorine pesticides in aqueous samples. A long adsorption time and small sample volume, which are problems encountered in conventional methods of stir bar sorptive extraction, were effectively solved by simultaneously using multiple stir bars for enrichment with sequential cryofocusing and merged injection. Optimised results showed good linear coefficients in the range of 10 to 500 ng/L and the method detection limits of 0.12-2.07 ng/L for polychlorinated biphenyls and organochlorine pesticides. The recovery ratios of the spiked samples at different concentrations were between 64.7 and 111.0%, and their relative standard deviations ranged from 0.9 to 17.6%. Four types of the studied compounds were determined in Qiantang River water samples, and their contents were between 0.82 and 5.00 ng/L. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Measurement of toxic volatile organic compounds in indoor air of semiconductor foundries using multisorbent adsorption/thermal desorption coupled with gas chromatography-mass spectrometry.

    PubMed

    Wu, Chien-Hou; Lin, Ming-Nan; Feng, Chien-Tai; Yang, Kuang-Ling; Lo, Yu-Shiu; Lo, Jiunn-Guang

    2003-05-09

    A method for the qualitative and quantitative analysis of volatile organic compounds (VOCs) in the air of class-100 clean rooms at semiconductor fabrication facilities was developed. Air samples from two semiconductor factories were collected each hour on multisorbent tubes (including Carbopack B, Carbopack C, and Carbosieve SIII) with a 24-h automatic active sampling system and analyzed using adsorption/thermal desorption coupled with gas chromatography-mass spectrometry. Experimental parameters, including thermal desorption temperature, desorption time, and cryofocusing temperature, were optimized. The average recoveries and the method detection limits for the target compounds were in the range 94-101% and 0.31-0.89 ppb, respectively, under the conditions of a 1 L sampling volume and 80% relative humidity. VOCs such as acetone, isopropyl alcohol, 2-heptanone, and toluene, which are commonly used in the semiconductor and electronics industries, were detected and accurately quantified with the established method. Temporal variations of the analyte concentrations observed were attributed to the improper use of organic solvents during operation.

  20. Nano-Optomechanical Systems for Gas Chromatography.

    PubMed

    Venkatasubramanian, Anandram; Sauer, Vincent T K; Roy, Swapan K; Xia, Mike; Wishart, David S; Hiebert, Wayne K

    2016-11-09

    Microgas chromatography (GC) is promising for portable chemical analysis. We demonstrate a nano-optomechanical system (NOMS) as an ultrasensitive mass detector in gas chromatography. Bare, native oxide, silicon surfaces are sensitive enough to monitor volatile organic compounds at ppm levels, while simultaneously demonstrating chemical selectivity. The NOMS is able to sense GC peaks from derivatized metabolites at physiological concentrations. This is an important milestone for small-molecule quantitation assays in next generation metabolite analyses for applications such as disease diagnosis and personalized medicine. The optical microring, which plays an important role in the nanomechanical signal transduction mechanism, can also be used as an analyte concentration sensor. Different adsorption kinetics regimes are realized at different temperatures allowing temporary condensation of the analyte onto the sensor surfaces. This effect amplifies the signal, resulting in a 1 ppb level limit of detection, without partition enhancement from absorbing media. This sensitivity bodes well for NOMS as universal, ultrasensitive detectors in micro-GC, breath analysis, and other chemical-sensing applications.

  1. Multidimensional gas chromatography beyond simple volatiles separation.

    PubMed

    Chin, Sung-Tong; Marriott, Philip J

    2014-08-18

    Multidimensional separation in gas chromatography (MDGC) plays an important role in chemical analysis. This review presents selected literature on MDGC development and examples of the range of functionality reported for MDGC methods over the past 2 decades. With the most obvious advantage of providing much greater capacity for resolving constituents of a sample, MDGC extends analytical efficiency to a more substantial molecular coverage, combined with operational flexibility. But by judicious choice of implementation method, important chemical information relating to the sample, its components, potentially physico-chemical properties, and improved capacity for absolute identification may be realised. Sample-to-sample comparison is improved, and sample characterisation is facilitated especially when MDGC is combined with the informing power of modern mass spectrometry. Innovative MDGC arrangements allow high resolution coupled with spectroscopy and alternative bioassays, and delivers molecular elucidation in ways that are beyond just simple analysis of volatiles.

  2. On-line monitoring of benzene air concentrations while driving in traffic by means of isotopic dilution gas chromatography/mass spectrometry.

    PubMed

    Davoli, E; Cappellini, L; Moggi, M; Ferrari, S; Fanelli, R

    1996-01-01

    There is no shortage of information about the average benzene concentrations in urban air, but there is very little about microenvironmental exposure, such as in-vehicle concentrations while driving in various traffic conditions, while refuelling, or while in a parking garage. The main reason for this lack of data is that no analytical instrumentation has been available to measure on-line trace amounts of benzene in such situations. We have recently proposed a highly accurate, high-speed cryofocusing gas chromatography/mass spectrometry (GC/MS) system for monitoring benzene concentrations in air. Accuracy of the analytical data is achieved by enrichment of the air sample before trapping, with a stable isotope permeation tube system. The same principles have been applied to a new instrument, specifically designed for operation on an electric vehicle (Ducato Elettra, Fiat). The zero emission vehicle and the fully transportable, battery-operated GC/MS system provide a unique possibility of monitoring benzene exposure in real everyday situations such as while driving, refuelling, or repairing a car. All power consumptions have been reduced so as to achieve a battery-operated GC/MS system. Liquid nitrogen cryofocusing has been replaced by a packed, inductively heated, graphitized charcoal microtrap. The instrument has been mounted on shock absorbers and installed in the van. The whole system has been tested in both fixed and mobile conditions. The maximum monitoring period without external power supply is 6 h. The full analytical cycle is 4 min, allowing close to real-time monitoring, and the minimum detectable level is 1 microgram/m3 for benzene. In-vehicle monitoring showed that, when recirculation was off and ventilation on, i.e., air from outside the vehicle was blown inside, concentrations varied widely in different driving conditions: moving from a parking lot into normal traffic on an urban traffic condition roadway yielded an increase in benzene concentration

  3. [Development of microwave plasma atomic emission detectors for gas chromatography].

    PubMed

    Yuan, Mao; Shi, Yuhua; Yu, Aimin; Zhang, Hanqi; Jin, Qinhan

    2007-05-01

    Three microwave plasmas including microwave induced plasma, capacitively coupled microwave plasma and microwave plasma torch as atomic emission detectors for gas chromatography are evaluated in their history, application and restriction, separately. The development of microwave plasma atomic emission detectors for gas chromatography is prospected.

  4. Freeze drying for gas chromatography stationary phase deposition

    DOEpatents

    Sylwester, Alan P.

    2007-01-02

    The present disclosure relates to methods for deposition of gas chromatography (GC) stationary phases into chromatography columns, for example gas chromatography columns. A chromatographic medium is dissolved or suspended in a solvent to form a composition. The composition may be inserted into a chromatographic column. Alternatively, portions of the chromatographic column may be exposed or filled with the composition. The composition is permitted to solidify, and at least a portion of the solvent is removed by vacuum sublimation.

  5. Applications of resistive heating in gas chromatography: a review.

    PubMed

    Jacobs, Matthew R; Hilder, Emily F; Shellie, Robert A

    2013-11-25

    Gas chromatography is widely applied to separate, identify, and quantify components of samples in a timely manner. Increasing demand for analytical throughput, instrument portability, environmental sustainability, and more economical analysis necessitates the development of new gas chromatography instrumentation. The applications of resistive column heating technologies have been espoused for nearly thirty years and resistively heated gas chromatography has been commercially available for the last ten years. Despite this lengthy period of existence, resistively heated gas chromatography has not been universally adopted. This low rate of adoption may be partially ascribed to the saturation of the market with older convection oven technology, coupled with other analytical challenges such as sampling, injection, detection and data processing occupying research. This article assesses the advantages and applications of resistive heating in gas chromatography and discusses practical considerations associated with adoption of this technology. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Vacuum ultraviolet detector for gas chromatography.

    PubMed

    Schug, Kevin A; Sawicki, Ian; Carlton, Doug D; Fan, Hui; McNair, Harold M; Nimmo, John P; Kroll, Peter; Smuts, Jonathan; Walsh, Phillip; Harrison, Dale

    2014-08-19

    Analytical performance characteristics of a new vacuum ultraviolet (VUV) detector for gas chromatography (GC) are reported. GC-VUV was applied to hydrocarbons, fixed gases, polyaromatic hydrocarbons, fatty acids, pesticides, drugs, and estrogens. Applications were chosen to feature the sensitivity and universal detection capabilities of the VUV detector, especially for cases where mass spectrometry performance has been limited. Virtually all chemical species absorb and have unique gas phase absorption cross sections in the approximately 120-240 nm wavelength range monitored. Spectra are presented, along with the ability to use software for deconvolution of overlapping signals. Some comparisons with experimental synchrotron data and computed theoretical spectra show good agreement, although more work is needed on appropriate computational methods to match the simultaneous broadband electronic and vibronic excitation initiated by the deuterium lamp. Quantitative analysis is governed by Beer-Lambert Law relationships. Mass on-column detection limits reported for representatives of different classes of analytes ranged from 15 (benzene) to 246 pg (water). Linear range measured at peak absorption for benzene was 3-4 orders of magnitude. Importantly, where absorption cross sections are known for analytes, the VUV detector is capable of absolute determination (without calibration) of the number of molecules present in the flow cell in the absence of chemical interferences. This study sets the stage for application of GC-VUV technology across a wide breadth of research areas.

  7. Moving thermal gradients in gas chromatography.

    PubMed

    Tolley, H Dennis; Tolley, Samuel E; Wang, Anzi; Lee, Milton L

    2014-12-29

    This paper examines the separation effects of a moving thermal gradient on a chromatographic column in gas chromatography. This movement of the gradient has a focusing effect on the analyte bands, limiting band broadening in the column. Here we examine the relationship between the slope of this gradient, the velocity of the gradient and the resulting band width. Additionally we examine how transport of analytes along the column at their analyte specific constant temperatures, determined by the gradient slope and velocity, affects resolution. This examination is based primarily on a theoretical model of partitioning and transport of analyte under low concentration conditions. Preliminary predictions indicate that analytes reach near constant temperatures, relative positions and resolutions in less than 100cm of column transport. Use of longer columns produces very little improvement in resolution for any fixed slope. Properties of the thermal gradient determine a fixed solute band width for each analyte. These widths are nearly reached within the first 40-70cm, after which little broadening or narrowing of the bands occur. The focusing effect of the thermal gradient corrects for broad injections, reduces effects of irregular stationary phase coatings and can be used with short columns for fast analysis. Thermal gradient gas chromatographic instrumentation was constructed and used to illustrate some characteristics predicted from the theoretical results.

  8. Chromatography

    MedlinePlus

    Chromatography is a way of separating two or more chemical compounds. Chemical compounds are chemicals that are ... of chemical compound. There are different kinds of chromatography. These include gas, high pressure liquid, or ion ...

  9. Gas chromatography using resistive heating technology.

    PubMed

    Wang, Anzi; Tolley, H Dennis; Lee, Milton L

    2012-10-26

    Air bath ovens are standard in conventional gas chromatography (GC) instruments because of their simplicity and reliability for column temperature control. However, their low heating rates, high power consumption and bulky size are in conflict with the increasing demands for fast separation and portable instrumentation. The deficiencies of air bath ovens can be eliminated using resistive heating technology, as the column is conductively heated by compact resistive heaters with low thermal mass. Resistive heating methods were employed in the early years of GC history, and they are emerging again as instrumentation is becoming more compact and sophisticated. Numerous designs have been tested and some have been successfully commercialized. Development of portable GC systems, including lab-on-a-chip devices, greatly benefits from the use of small, low-power resistive heating hardware. High speed GC separations using conventional instruments also can be best achieved with resistive heating modules. Despite some of its own inherent disadvantages, including efficiency loss, complex manufacturing and inconvenient column maintenance, resistive heating is expected to rapidly become a mature technology and even replace oven heating in the not-to-distant future.

  10. Mixed Stationary Liquid Phases for Gas-Liquid Chromatography.

    ERIC Educational Resources Information Center

    Koury, Albert M.; Parcher, Jon F.

    1979-01-01

    Describes a laboratory technique for use in an undergraduate instrumental analysis course that, using the interpretation of window diagrams, prepares a mixed liquid phase column for gas-liquid chromatography. A detailed procedure is provided. (BT)

  11. ENVIRONMENTAL APPLICATION OF GAS CHROMATOGRAPHY/ATOMIC EMISSION DETECTION

    EPA Science Inventory

    A gas chromatography/atomic emission detector (GC/AED) system has been evaluated for its applicability to environmental analysis. Detection limits, elemental response factors, and regression analysis data were determined for 58 semivolatile environmental contaminants. Detection l...

  12. ENVIRONMENTAL APPLICATION OF GAS CHROMATOGRAPHY/ATOMIC EMISSION DETECTION

    EPA Science Inventory

    A gas chromatography/atomic emission detector (GC/AED) system has been evaluated for its applicability to environmental analysis. Detection limits, elemental response factors, and regression analysis data were determined for 58 semivolatile environmental contaminants. Detection l...

  13. Mixed Stationary Liquid Phases for Gas-Liquid Chromatography.

    ERIC Educational Resources Information Center

    Koury, Albert M.; Parcher, Jon F.

    1979-01-01

    Describes a laboratory technique for use in an undergraduate instrumental analysis course that, using the interpretation of window diagrams, prepares a mixed liquid phase column for gas-liquid chromatography. A detailed procedure is provided. (BT)

  14. Solid surface mapping by inverse gas chromatography.

    PubMed

    Gutiérrez, M C; Osuna, S; Baráibar, I

    2005-09-16

    Inverse gas chromatography (IGC) at infinite dilution, is a technique for characterising solid surfaces. Current practice is the injection of n-alkane homologous series to obtain the free energy of adsorption of the CH2 group, from which the London component of the solid surface free energy, gamma(d)s, is calculated. A value around 40 mJ/m2 is obtained for poly(ethylene), and 30 mJ/m2 for a clean glass fibre, while the potential surface interactivity of a glass fibre is far greater than that of poly(ethylene). A specific component of the surface, in mJ/m2, should be calculated in order to obtain significant parameters. As applied up to date, when calculating the specific component of the surface energy, the fact that W(sp)a energy values are in a totally different scale than AN or DN values is a major drawback. Consequently, Ka and Kb values obtained are in arbitrary energy units, different from those of the London component measured by injecting the n-alkane series. This paper proposes a method to obtain Ka and Kb values of the surface in the same energetic scale than the London component. The method enables us to correct the traditional London component of a solid, obtaining a new value, where the amount of WaCH2 accounting for Debye interactions with polar sites, is excluded. As a result, an approach to surface mapping is performed in several different substrate materials. We show results obtained on different solid surfaces: poly(ethylene), clean glass fibre, glass beads, chemically modified glass beads and carbon fibre.

  15. Application of isotopic labeling, and gas chromatography mass spectrometry, to understanding degradation products and pathways in the thermal-oxidative aging of Nylon 6.6

    SciTech Connect

    White, Gregory Von; Clough, Roger L.; Hochrein, James M.; Bernstein, Robert

    2013-12-01

    Nylon 6.6 containing 13C isotopic labels at specific positions along the macromolecular backbone has been subjected to extensive thermal-oxidative aging at 138 °C for time periods up to 243 days. In complementary experiments, unlabeled Nylon 6.6 was subjected to the same aging conditions under an atmosphere of 18O2. Volatile organic degradation products were analyzed by cryofocusing gas chromatography mass spectrometry (cryo-GC/MS) to identify the isotopic labeling. The labeling results, combined with basic considerations of free radical reaction chemistry, provided insights to the origin of degradation species, with respect to the macromolecular structure. A number of inferences on chemical mechanisms were drawn, based on 1) the presence (or absence) of the isotopic labels in the various products, 2) the location of the isotope within the product molecule, and 3) the relative abundance of products as indicated by large differences in peak intensities in the gas chromatogram. The overall degradation results can be understood in terms of free radical pathways originating from initial attacks on three different positions along the nylon chain which include hydrogen abstraction from: the (CH2) group adjacent to the nitrogen atom, at the (CH2) adjacent the carbonyl group, and direct radical attack on the carbonyl. Understanding the pathways which lead to Nylon 6.6 degradation ultimately provides new insight into changes that can be leveraged to detect and reduce early aging and minimize problems associated with material degradation.

  16. [Analysis of saturated paraffins in petroleum by fast gas chromatography].

    PubMed

    Wu, Jie; Cao, Lei; Li, Yingming; Hashi, Yuki

    2004-09-01

    A fast capillary gas chromatographic method for the analysis of saturated paraffin in crude oil and rock extracts is described. By using a 20 m narrow bore capillary column, the analytical time has been shortened to 15 min, 5 times faster in comparison with 80 to 90 min by conventional capillary columns, which resulted in higher throughput, higher efficiency and better separation. The fast method is fully in compliance with the Petroleum Industrial Standard--SY/T5120-1997 and paves the way for the fast analysis of paraffin isomers, such as steroidal paraffin and terpane by gas chromatography/mass spectrometry (GC/MS) and that of aromatics by gas chromatography.

  17. Less common applications of monoliths III. Gas chromatography

    PubMed Central

    Svec, Frantisek; Kurganov, Alexander A.

    2008-01-01

    Porous polymer monoliths emerged about two decades ago. Despite this short time, they are finding applications in a variety of fields. In addition to the most common and certainly best known use of this new category of porous media as stationary phases in liquid chromatography, monolithic materials also found their applications in other areas. This review article focuses on monoliths in capillaries designed for separations in gas chromatography. PMID:17645884

  18. Development of stir-bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry for the analysis of musks in vegetables and amended soils.

    PubMed

    Aguirre, Josu; Bizkarguenaga, Ekhiñe; Iparraguirre, Arantza; Fernández, Luis Ángel; Zuloaga, Olatz; Prieto, Ailette

    2014-02-17

    The aim of this study was to develop a sensitive and environment-friendly method based on stir-bar sorptive extraction (SBSE) followed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) to determine 8 synthetic musks (musk ambrette, musk ketone, celestolide, tonalide, galaxolide, phantolide, traseolide, and cashmeran) in vegetables (lettuce, carrot, and pepper) and amended soil samples. In a first step sorptive extraction was studied both in the headspace (HSSE) and in the immerse mode (SBSE). The best results were obtained in the immersion mode which was further studied. The influence of the main factors: methanol (20%) and NaCl addition (0%), extraction temperature (40°C) and time (180 min), extraction solvent volume (9 mL) and stirring rate (600 rpm) on the efficiency of SBSE was evaluated by means of experimental designs. In the case of TD, desorption time (10 min), desorption temperature (300°C), cryo-focusing temperature (-30°C), vent flow (75 mL/min) and vent pressure (7.2 psi) were studied using both a fractioned factorial design and a central composite design (CCD). The method was validated in terms of apparent recoveries (AR%), method detection limits (MDLs) and precision at two different concentration levels. Although quantification using instrumental calibration rendered odd results in most of the cases, satisfactory recoveries (74-126%) were obtained in the case of matrix-matched calibration approach for all of the analytes and matrices studied at the two concentration levels evaluated. MDLs in the range of 0.01-0.8 ng/g and 0.01-1.1 ng/g were obtained for vegetables and amended soil samples, respectively. RSD values within 1-23% were obtained for all the analytes and matrices. Finally, the method was applied to the determination of musks in vegetable and amended soil samples.

  19. Gas chromatography/matrix-isolation apparatus

    DOEpatents

    Reedy, Gerald T.

    1986-01-01

    A gas-sample collection device provides matrix isolation of individual gas bands from a gas chromatographic separation and for the spectroscopic analysis of the individual sample bands. The device includes a vacuum chamber containing a rotatably supported, specular carousel having at least one reflecting surface for holding a sample deposited thereon. A gas inlet is provided for depositing a mixture of sample and matrix material on the reflecting surface which is maintained at a sufficiently low temperature to cause solidification. A first parabolic mirror directs an incident beam of electromagnetic radiation, such as in the infrared (IR) spectrum, from a source onto the sample/matrix mixture while a second parabolic mirror directs a second beam of electromagnetic radiation reflected by the specular surface to an IR spectrometer for determining the absorption spectra of the sample material deposited on the reflecting surface. The pair of off-axis parabolic mirrors having a common focal point are positioned outside of the vacuum chamber and may be displaced in combination for improved beam positioning and alignment. The carousel is provided with an aperture for each reflecting surface to facilitate accurate positioning of the incident beam relative to the gas-samples under analysis. Improved gas-sample deposition is insured by the use of a long focal length stereomicroscope positioned outside of the vacuum chamber for monitoring sample formation through a window, while the sample collector is positioned outside of the zone bounded by the incident and reflected electromagnetic beams for improved sample access and monitoring.

  20. Micromachined Gas Chromatography Microsystem For Complex Gas Analysis (BRIEFING CHARTS)

    DTIC Science & Technology

    2007-03-07

    Wireless Integrated Microsystems (WIMS), Applications • Gas Analysis Using µGC • The “Actuator”: Integrated Gas Micropump • Concluding Remarks, Future...mode Analysis mode • No previous gas micropump meets the WIMS µGC requirements. • Size and power...leakage. • Single mode operation Summary of Previous Gas Micropumps NSF ERC for Wireless Integrated MicroSystems (WIMS) 22 • Goal: Develop a miniature

  1. Gas chromatography/matrix-isolation apparatus

    DOEpatents

    Reedy, G.T.

    1986-06-10

    A gas-sample collection device provides matrix isolation of individual gas bands from a gas chromatographic separation and for the spectroscopic analysis of the individual sample bands. The device includes a vacuum chamber containing a rotatably supported, specular carousel having at least one reflecting surface for holding a sample deposited thereon. A gas inlet is provided for depositing a mixture of sample and matrix material on the reflecting surface which is maintained at a sufficiently low temperature to cause solidification. A first parabolic mirror directs an incident beam of electromagnetic radiation, such as in the infrared (IR) spectrum, from a source onto the sample/matrix mixture while a second parabolic mirror directs a second beam of electromagnetic radiation reflected by the specular surface to an IR spectrometer for determining the absorption spectra of the sample material deposited on the reflecting surface. The pair of off-axis parabolic mirrors having a common focal point are positioned outside of the vacuum chamber and may be displaced in combination for improved beam positioning and alignment. The carousel is provided with an aperture for each reflecting surface to facilitate accurate positioning of the incident beam relative to the gas-samples under analysis. Improved gas-sample deposition is insured by the use of a long focal length stereomicroscope positioned outside of the vacuum chamber for monitoring sample formation through a window, while the sample collector is positioned outside of the zone bounded by the incident and reflected electromagnetic beams for improved sample access and monitoring. 10 figs.

  2. Highly crosslinked silicon polymers for gas chromatography columns

    NASA Technical Reports Server (NTRS)

    Shen, Thomas C. (Inventor)

    1994-01-01

    A new highly crosslinked silicone polymer particle for gas chromatography application and a process for synthesizing such copolymer are described. The new copolymer comprises vinyltriethoxysilane and octadecyltrichlorosilane. The copolymer has a high degree of crosslinking and a cool balance of polar to nonpolar sites in the porous silicon polymer assuring fast separation of compounds of variable polarity.

  3. An application of gas chromatography to planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Oyama, V.

    1974-01-01

    A gas chromatography developed for the Viking experiment is described. The instrument is designed to measure gases in planetary atmospheres and head space in a chamber. It is hoped that the chromatograph will also measure any biological activity present in these environments.

  4. Enthalpy of Vaporization by Gas Chromatography: A Physical Chemistry Experiment

    ERIC Educational Resources Information Center

    Ellison, Herbert R.

    2005-01-01

    An experiment is conducted to measure the enthalpy of vaporization of volatile compounds like methylene chloride, carbon tetrachloride, and others by using gas chromatography. This physical property was measured using a very tiny quantity of sample revealing that it is possible to measure the enthalpies of two or more compounds at the same time.

  5. Using Single Drop Microextraction for Headspace Analysis with Gas Chromatography

    ERIC Educational Resources Information Center

    Riccio, Daniel; Wood, Derrick C.; Miller, James M.

    2008-01-01

    Headspace (HS) gas chromatography (GC) is commonly used to analyze samples that contain non-volatiles. In 1996, a new sampling technique called single drop microextraction, SDME, was introduced, and in 2001 it was applied to HS analysis. It is a simple technique that uses equipment normally found in the undergraduate laboratory, making it ideal…

  6. Simulation of the Physical Chemistry of Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Haigh, John; Lord, J. R.

    2000-11-01

    A menu allows navigation between the sections of Simulation of the Physical Chemistry of Gas Chromatography. Experiments can be stopped and restarted easily. Many definitions and other technical points are available as hypertext. The student is encouraged to look quickly through the whole package, then to carefully work through the text and experiments.

  7. Using Single Drop Microextraction for Headspace Analysis with Gas Chromatography

    ERIC Educational Resources Information Center

    Riccio, Daniel; Wood, Derrick C.; Miller, James M.

    2008-01-01

    Headspace (HS) gas chromatography (GC) is commonly used to analyze samples that contain non-volatiles. In 1996, a new sampling technique called single drop microextraction, SDME, was introduced, and in 2001 it was applied to HS analysis. It is a simple technique that uses equipment normally found in the undergraduate laboratory, making it ideal…

  8. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    ERIC Educational Resources Information Center

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  9. Enthalpy of Vaporization by Gas Chromatography: A Physical Chemistry Experiment

    ERIC Educational Resources Information Center

    Ellison, Herbert R.

    2005-01-01

    An experiment is conducted to measure the enthalpy of vaporization of volatile compounds like methylene chloride, carbon tetrachloride, and others by using gas chromatography. This physical property was measured using a very tiny quantity of sample revealing that it is possible to measure the enthalpies of two or more compounds at the same time.

  10. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    ERIC Educational Resources Information Center

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  11. Investigating Interphase Development in Woodpolymer Composites by Inverse Gas Chromatography

    Treesearch

    Timothy G. Rials; John Simonsen

    2000-01-01

    The influence of secondary interactions on the development of interfacial structure in composites of wood and amorphous thermoplastic polymers is not well understood. This study used inverse gas chromatography to investigate the effect of different polymers on the surface energy of partially or fully coated white pine wood meal. In this way, the development of the...

  12. Quantitative determination of hydrogen in solids by gas chromatography.

    PubMed

    Addach, H; Berçot, P; Wery, M; Rezrazi, M

    2004-11-19

    Processes such as electroplating or acid cleaning are notorious causes of post-processing failure through hydrogen embrittlement. So, the determination of amounts of hydrogen in metals is of great importance. An analysis method for investigation of H content in solids has been established based on hot extraction and gas chromatography system. Hot extraction in inert gas enables complete and/or partial removal of the hydrogen from the samples. A gas chromatography system is used to determine quantitatively the amount of thermally desorbed hydrogen. An investigation of the baking operating conditions is made of the hydrogen desorption rate of zinc-plated steel parts. Then, an analysis of the polarisation conditions upon chromium electroplating is given.

  13. Multiplex gas chromatography for use in space craft

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.

    1985-01-01

    Gas chromatography is a powerful technique for the analysis of gaseous mixtures. Some limitations in this technique still exist which can be alleviated with multiplex gas chromatography (MGC). In MGC, rapid multiple sample injections are made into the column without having to wait for one determination to be finished before taking a new sample. The resulting data must then be reduced using computational methods such as cross correlation. In order to efficiently perform multiplexgas chromatography, experiments in the laboratory and on board future space craft, skills, equipment, and computer software were developed. Three new techniques for modulating, i.e., changing, sample concentrations were demonstrated by using desorption, decomposition, and catalytic modulators. In all of them, the need for a separate gas stream as the carrier was avoided by placing the modulator at the head of the column to directly modulate a sample stream. Finally, the analysis of an environmental sample by multiplex chromatography was accomplished by employing silver oxide to catalytically modulate methane in ambient air.

  14. Cryogen free automated gas chromatography for the measurement of ambient volatile organic compounds.

    PubMed

    Wang, J L; Chen, W L; Lin, Y H; Tsai, C H

    2000-10-27

    An automated gas chromatographic system was constructed for measuring ambient volatile organic compounds (VOCs). Preconcentration of the VOCs was performed by using two separated sorbent traps of different combinations with each designated for either low or high boiling VOCs. Both traps and their associated valve systems were integrated as a complete system sharing a common sample inlet. Precise temperature controls for desorption relied on the use of a process controller with proportional-integral-derivative algorithm to throttle the current supply. No additional cryo-focusing stage prior to the column was needed owing to the flash heating capability for desorption. Other than the cryogen free preconcentration and focusing, the separation of VOCs of large volatility difference was also performed without cryogen. The system employed an Al2O3/KCl porous-layer open tubular column for separating C3-C7 compounds; and a DB-1 column for C6-C12. This automated GC system has been deployed in a Taiwan Environmental Protection Agency urban air quality monitoring station of Taiwan for continuous measuring C3-C7 ozone precursors. Excellent correlation between the car exhaust type of compounds measured by our GC system and carbon monoxide measured by a non-dispersive infrared spectrometer was observed, suggesting the automated GC system was robust and reliable.

  15. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid chromatography system for clinical use is a device intended to separate one or more drugs or compounds from a...

  16. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid chromatography system for clinical use is a device intended to separate one or more drugs or compounds from a...

  17. The determination of soil moisture by extraction and gas chromatography

    NASA Technical Reports Server (NTRS)

    Merek, E. L.; Carle, G. C.

    1974-01-01

    Soil moisture content was determined by extracting soil with methanol and subsequently analyzing the extract for water by gas chromatography. With air-dried mineral soils, this method gave slightly higher moisture content values than those obtained by the oven-dry method. Moisture content was determined quantitatively in soils to which various amounts of water had been added. The complete procedure, including extraction and analysis, requires less than one hour and gives results that closely compare to the oven-dry method.

  18. Chelate-modified polymers for atmospheric gas chromatography

    NASA Technical Reports Server (NTRS)

    Christensen, W. W.; Mayer, L. A.; Woeller, F. H. (Inventor)

    1980-01-01

    Chromatographic materials were developed to serve as the stationary phase of columns used in the separation of atmospheric gases. These materials consist of a crosslinked porous polymer matrix, e.g., a divinylbenzene polymer, into which has been embedded an inorganic complexed ion such as N,N'-ethylene-bis-(acetylacetoniminato)-cobalt (2). Organic nitrogenous bases, such as pyridine, may be incorporated into the chelate polymer complexes to increase their chromatographic utility. With such materials, the process of gas chromatography is greatly simplified, especially in terms of time and quantity of material needed for a gas separation.

  19. [Identification of narcotics in urine by capillary gas chromatography].

    PubMed

    Akalaev, A N; Shpagin, M G; Shabolenko, V P; Kovalenko, A E

    2004-01-01

    It is demonstrated that gas chromatography with quartz capillary columns (QCC) and with cross-sewn SE-52 by polysiloxane provides for the possibility to divide and identify, in human urine, 16 narcotic substances of the amphetamine, 1.4-benzodiazepine, morphine and other groups. The suggested extraction method makes it possible to isolate the above compounds from urine simultaneously and, after derivatization, to determine them by gas chromatography (GC) with programmed temperature within one stage analysis session. GC tests were performed on 2 both foreign and Russian QCC with SE-52. There is a description of 2 methods of how to obtain the trifluor-acetyl derivatives (TFA-derivatives) by using trifluor-acetate anhydride and N-methyl-bis-trifluor-acetamide. The limit of detecting the TFA-derivatives was 1-2 ng for the plasma-ionizing detector. The extraction method as well as the positive and negative aspects of using the TFA-derivatives are under discussion. The method of gas-chromatography/mass-spectrometry confirms that the positive results of radioreceptor assay are verified by GC in 92% of cases.

  20. Characterisation of odorants in roasted stem tea using gas chromatography-mass spectrometry and gas chromatography-olfactometry analysis.

    PubMed

    Sasaki, Tetsuya; Koshi, Erina; Take, Harumi; Michihata, Toshihide; Maruya, Masachika; Enomoto, Toshiki

    2017-04-01

    Roasted stem tea has a characteristic flavour, which is obtained by roasting tea stems, by-product of green tea production. This research aims to understand the characteristic odorants in roasted stem tea by comparing it to roasted leaf tea. We revealed potent odorants in commercial roasted stem tea using gas chromatography-mass spectrometry (GC-MS) and gas chromatography-olfactometry with aroma extract dilution analysis (AEDA). The difference between roasted stem and leaf tea derived from the same tea plants were investigated using GC-MS. Pyrazine compounds exhibited a roasted odour and high flavour dilution (FD) factors, as determined via AEDA. Roasted stem tea was richer in these pyrazines than roasted leaf tea. Geraniol and linalool exhibited high FD factors and a floral odour, and roasted stem tea was richer in these compounds than roasted leaf tea. These results may have a positive impact on the development of tea products.

  1. Pyrolysis-high resolution gas chromatography and pyrolysis gas chromatography-mass spectrometry of kerogens and kerogen precursors

    NASA Technical Reports Server (NTRS)

    Van De Meent, D.; Brown, S. C.; Philp, R. P.; Simoneit, B. R. T.

    1980-01-01

    A series of kerogens and kerogen precursors isolated from DSDP samples, oil shales and recent algal mats have been examined by Curie point pyrolysis-high resolution gas chromatography and gas chromatography-mass spectrometry. This study has shown that the three main types of kerogens (marine, terrestrial and mixtures of both) can be characterized using these techniques. The marine (algal) kerogens yield principally aliphatic products and the terrestrial kerogens yield more aromatic and phenolic products with some n-alkanes and n-alkenes. The yields of n-alkanes and n-alkenes increase and phenols decrease with increasing geologic age, however, pyrolysis-GC cannot be used to characterize the influence of short term diagenesis on the kerogen structure.

  2. Pyrolysis-high resolution gas chromatography and pyrolysis gas chromatography-mass spectrometry of kerogens and kerogen precursors

    NASA Technical Reports Server (NTRS)

    Van De Meent, D.; Brown, S. C.; Philp, R. P.; Simoneit, B. R. T.

    1980-01-01

    A series of kerogens and kerogen precursors isolated from DSDP samples, oil shales and recent algal mats have been examined by Curie point pyrolysis-high resolution gas chromatography and gas chromatography-mass spectrometry. This study has shown that the three main types of kerogens (marine, terrestrial and mixtures of both) can be characterized using these techniques. The marine (algal) kerogens yield principally aliphatic products and the terrestrial kerogens yield more aromatic and phenolic products with some n-alkanes and n-alkenes. The yields of n-alkanes and n-alkenes increase and phenols decrease with increasing geologic age, however, pyrolysis-GC cannot be used to characterize the influence of short term diagenesis on the kerogen structure.

  3. Determination of Vinyl Chloride at ug/l. Level in Water by Gas Chromatography

    ERIC Educational Resources Information Center

    Bellar, Thomas A.; And Others

    1976-01-01

    A quantitative method for the determination of vinyl chloride in water is presented. Vinyl chloride is transfered to the gas phase by bubbling inert gas through the water. After concentration on silica gel or Carbosieve-B, determination is by gas chromatography. Confirmation of vinyl chloride is by gas chromatography-mass spectrometry. (Author/BT)

  4. Determination of Vinyl Chloride at ug/l. Level in Water by Gas Chromatography

    ERIC Educational Resources Information Center

    Bellar, Thomas A.; And Others

    1976-01-01

    A quantitative method for the determination of vinyl chloride in water is presented. Vinyl chloride is transfered to the gas phase by bubbling inert gas through the water. After concentration on silica gel or Carbosieve-B, determination is by gas chromatography. Confirmation of vinyl chloride is by gas chromatography-mass spectrometry. (Author/BT)

  5. Ultratrace detector for hand-held gas chromatography

    DOEpatents

    Andresen, Brian D.; Miller, Fred S.

    1999-01-01

    An ultratrace detector system for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and C0.sub.2. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica--or other metal--aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.

  6. Ultratrace detector for hand-held gas chromatography

    SciTech Connect

    Andresen, B.D.; Miller, F.S.

    1999-11-09

    An ultratrace detector system is described for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and CO{sub 2}. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica-or other metal-aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.

  7. The Use of Gas Chromatography for Biogas Analysis

    NASA Astrophysics Data System (ADS)

    Andersen, Amanda; Seeley, John; Aurandt, Jennifer

    2010-04-01

    Energy from natural gas accounts for 24 percent of energy consumed in the US. Natural gas is a robust form of energy which is rich in methane content and is low in impurities. This quality suggests that it is a very clean and safe gas; it can be used in providing heat, a source for cooking, and in powering vehicles. The downside is that it is a non-renewable resource. On the contrary, methane rich gas that is produced by the breakdown of organic material in an anaerobic environment, called biogas, is a renewable energy source. This research focuses on the gas analysis portion of the creation of the anaerobic digestion and verification laboratory where content and forensic analysis of biogas is performed. Gas Chromatography is implemented as the optimal analytical tool for quantifying the components of the biogas including methane, carbon dioxide, hydrogen sulfide and siloxanes. In addition, the problems associated with the undesirable components are discussed. Anaerobic digestion of primary sludge has consistently produced about 55 percent methane; future goals of this research include studying different substrates to increase the methane yield and decrease levels of impurities in the gas.

  8. Analysis of chemically synthesized oleoylethanolamide by gas-liquid chromatography.

    PubMed

    Thabuis, Clémentine; Tissot-Favre, Delphine; Bezelgues, Jean-Baptiste; Martin, Jean-Charles; Cruz-Hernandez, Cristina; Dionisi, Fabiola; Destaillats, Frédéric

    2008-08-22

    Oleoylethanolamide (OEA) is known to potentially have beneficial biological effects on weight management by controlling food intake and activating lipid catabolism. In biological fluids, OEA and other endogenously biosynthesized fatty acid ethanolamides are usually analyzed by liquid chromatography-mass spectrometry (LC-MS). The present study provides analytical method to routinely assess the quality of OEA prepared for biological studies by gas-liquid chromatography (GLC). The preparation of OEA for biomedical studies can be performed by N-acylation of oleic acid/esters or using oleoyl chloride. In the present study, OEA was prepared by transamidation of triolein. The analysis of the synthesized OEA has been performed by gas-liquid chromatography of its trimethylsilyl ether (TMS) derivatives. Free OEA cannot be analyzed as such because dehydration of the ethanolamide moiety promptly happens in the GLC injection. This thermal degradation reaction gives rise to the formation of an oxazoline derivative. The TMS moiety prevents the reaction, and the structure of the formed derivative was assessed by mass spectrometry. We show here that OEA prepared for biological studies can be routinely analyzed by GLC after TMS derivative preparation.

  9. High-throughput gas chromatography for volatile compounds analysis by fast temperature programming and adsorption chromatography.

    PubMed

    Gras, Ronda; Hua, Yujuan; Luong, Jim

    2017-05-01

    The synergy of combining fast temperature programming capability and adsorption chromatography using fused silica based porous layer open tubular columns to achieve high throughput chromatography for the separation of volatile compounds is presented. A gas chromatograph with built-in fast temperature programming capability and having a fast cool down rate was used as a platform. When these performance features were combined with the high degree of selectivity and strong retention characteristic of porous layer open tubular column technology, volatile compounds such as light hydrocarbons of up to C7 , primary alcohols, and mercaptans can be well separated and analyzed in a matter of minutes. This analytical approach substantially improves sample throughput by at least a factor of ten times when compared to published methodologies. In addition, the use of porous layer open tubular columns advantageously eliminates the need for costly and time-consuming cryogenic gas chromatography required for the separation of highly volatile compounds by partition chromatography with wall coated open tubular column technology. Relative standard deviations of retention time for model compounds such as alkanes from methane to hexane were found to be less than 0.3% (n = 10) and less than 0.5% for area counts for the compounds tested at two levels of concentration by manual injection, namely, 10 and 1000 ppm v/v (n = 10). Difficult separations were accomplished in one single analysis in less than 2 min such as the characterization of 17 components in cracked gas containing alkanes, alkenes, dienes, branched hydrocarbons, and cyclic hydrocarbons. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Characterization of crude oils by inverse gas chromatography.

    PubMed

    Mutelet, F; Ekulu, G; Rogalski, M

    2002-09-06

    It was shown that the flocculation onset of asphaltenes in crude oils could be predicted on the basis of the inverse gas chromatography characterization of the crude oil properties. Hildebrand's solubility parameters of four crude oils were calculated from inverse chromatography data and compared with values obtained from the onset of asphaltene flocculation measurements. A good agreement was observed with three crude oils of different origin. A relation between Hildebrand's solubility parameter and linear solvation energy relationship descriptors was established and it was demonstrated that the solubility parameter of a crude oil is determined mainly with dispersion interactions and the hydrogen bond basicity. A large basicity lowers the oil solubility parameter, and increases its stability in respect to flocculation.

  11. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    PubMed

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Determination of Free-Energy Relationships Using Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Snow, Nicholas H.

    1996-06-01

    By performing a few straightforward analyses on a gas chromatograph, it is possible to calculate the free energy, enthalpy, and entropy changes that occur when a compound transfers between the mobile and stationary phases. The partition theory of chromatography allows this transfer to be expressed as a chemical equlibrium. By calculating the equilibrium constant for this reaction from chromatographic retention times, the standard free energy change may be determined, and from this, the standard enthalpy and entropy changes. Also, by calculating these values at several temperatures for structurally related compounds, it is possible to explore the relationship between chromatographic retention, standard free energy, and the structure of a compound. These calculations were performed for groups of homologous alcohols, acetates, and hydrocarbons on packed and capillary column gas chromatographs, using both polar and non-polar columns, and on computer simulation software. It is seen that for homologous compounds, the relationship between standard free energy change in partitioning and hydrocarbon chain length for this reaction is linear. It is also seen that gas chromatography represents a useful tool for the calculation and comparison of thermodynamic properties of compounds and that straightforward exercise of this type allows training of students in chromatographic analysis, basic partition theory, thermodynamic relationships, and linear free energy relationships.

  13. MEMS Liquid and Gas Chromatography for Miniaturized Planetary In Situ Instruments

    NASA Astrophysics Data System (ADS)

    Kidd, R. D.; Bae, B.; Willis, P. A.; Noell, A. C.; Scianmarello, N.; Tai, Y.-C.

    2016-10-01

    Micro-Electro-Mechanical Systems (MEMS) technology to reduce the size, mass and power of the three classical chromatographic technologies: gas chromatography (GC), capillary electrophoresis (CE) and high performance liquid chromatography (HPLC).

  14. Multidimensional gas chromatography using microfluidic switching and low thermal mass gas chromatography for the characterization of targeted volatile organic compounds.

    PubMed

    Luong, J; Gras, R; Hawryluk, M; Shellie, R A; Cortes, H J

    2013-05-03

    Volatile organic compounds such as light hydrocarbons, dienes, and aromatic compounds are often encountered in the manufacturing and processing environments of chemical and petrochemical segments. These compounds need to be closely monitored for process optimization, plant maintenance and industrial hygiene purposes. A high throughput analytical approach has been successfully developed and implemented for the accurate measurement of fourteen commonly encountered analytes. The approach incorporates a recently introduced 5-port planar microfluidic device configured for use as a Deans switch for multidimensional gas chromatography. The use of multidimensional gas chromatography allows the elimination of potential chromatographic contaminants with a substantial enhancement of stationary phase selectivity via the use of columns with different separation mechanisms, and the back-flushing of heavier undesired hydrocarbons. A low thermal mass gas chromatographic module was employed in the second dimension of the two-dimensional gas chromatography system and was used to provide independent temperature control, and rapid heating and cooling to meet the high throughput requirements. By successfully combining these concepts, complete analysis of fourteen targeted components can be conducted in less than 120s. Repeatability of retention times for all compounds was found to be less than 0.05% (n=20). Repeatability of area counts at two levels, namely 10ppmv and 1000ppmv over a period of two days was found to be less than 3% (n=20). Apart from methane, which has a detection limit of 0.4ppmv, the rest of the compounds were found to have detection limits of less than 0.2ppmv. Compounds of interest were found to be linear over a range of 500ppbv-3000ppmv with correlation coefficients greater than 0.999. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Analysis and quantification of plant membrane lipids by thin-layer chromatography and gas chromatography.

    PubMed

    Wewer, Vera; Dörmann, Peter; Hölzl, Georg

    2013-01-01

    Galactolipids represent the predominant membrane lipid class in plants. In general, galactolipids are restricted to plastids, but during phosphate deficiency, they also accumulate in extraplastidial membranes. Two groups of plants can be distinguished based on the presence of a specific fatty acid, hexadecatrienoic acid (16:3), in chloroplast lipids. Plants that contain galactolipids with 16:3 acids are designated "16:3-plants"; the other group of plants which lack 16:3 contain mostly 18:3 in their galactolipids ("18:3-plants"). The methods in this chapter describe the extraction of membrane lipids from whole leaves, or from subcellular fractions, and their analysis via thin-layer chromatography (TLC) with different staining methods. Furthermore, a protocol for membrane lipid quantification is presented starting with the separation via TLC, transmethylation of the isolated lipids to fatty acid methyl esters, and their quantitative analysis via gas chromatography (GC).

  16. Analysis of beechwood creosote by gas chromatography-mass spectrometry and high-performance liquid chromatography.

    PubMed

    Ogata, N; Baba, T

    1989-12-01

    Compounds in beechwood creosote were analyzed by gas chromatography-mass spectrometry, and 22 major constituents were identified. Of these, 19 were phenolic compounds, i. e., guaiacol, phenol, two cresol isomers, four methylguaiacol (creosol) isomers, six xylenol isomers, two trimethylphenol isomers, 4-ethylguaiacol, 4-ethyl-5-methylguaiacol, and 4-propylguaiacol. The remaining three were hitherto unpredicted five-membered ring compounds, i. e., 3-methyl-2-hydroxy-2-cyclopenten-1-one, 3,5-dimethyl-2-hydroxy-2-cyclopenten-1-one, and 3-ethyl-2-hydroxy-2-cyclopenten-1-one. The relative quantities of these compounds were also compared with those obtained by high-resolution high-performance liquid chromatography. This report probably represents the first extensive analysis of beechwood creosote.

  17. Gas chromatography and high-performance liquid chromatography of natural steroids.

    PubMed

    Shimada, K; Mitamura, K; Higashi, T

    2001-11-23

    This review article underlines the importance of gas chromatography (GC), high-performance liquid chromatography (HPLC) and their hyphenated techniques using mass spectrometry (MS) for the determination of natural steroids, especially in human biological fluids. Steroids are divided into eight categories based on their structures and functions, and recent references using the above methodologies for the analysis of these steroids are cited. GC and GC-MS are commonly used for the determination of volatile steroids. Although HPLC is a widely used analytical method for the determination of steroids including the conjugated type in biological fluids, LC-MS is considered to be the most promising one for this purpose because of its sensitivity, specificity and versatility.

  18. Thermal History Of PMRs Via Pyrolysis-Gas Chromatography

    NASA Technical Reports Server (NTRS)

    Gluyas, Richard E.; Alston, William B.; Snyder, William J.

    1994-01-01

    Pyrolysis-gas chromatography (PY-GC) useful as analytical technique to determine extents of cure or postcure of PMR-15 polyimides and to lesser extent, cumulative thermal histories of PMR-15 polyimides exposed to high temperatures. Also applicable for same purposes to other PMR polyimides and to composite materials containing PMR polyimides. Valuable in reducing costs and promoting safety in aircraft industry by helping to identify improperly cured or postcured PMR-15 composite engine and airframe components and helping to identify composite parts nearing ends of their useful lives.

  19. Continuous monitoring of a changing sample by multiplex gas chromatography

    NASA Technical Reports Server (NTRS)

    Valentin, Jose R.; Hall, Kirsten W.; Becker, Joseph F.

    1990-01-01

    Results are presented from a study in which a continuously changed gaseous sample was monitored by multiplex gas chromatography (MGC), using the exponential dilution (ED) technique of Ritter and Adams (1976) to change the composition and concentration of a gaseous mixture in such a way as to imitate changes in the atmospheric gases sampled by a descending aircraft. A calibration of the MGC system was performed with four different rates of sample dilution, and the errors resulting from various degrees of change in the sample concentration were determined.

  20. Gas-liquid chromatography in lunar organic analysis.

    NASA Technical Reports Server (NTRS)

    Gehrke, C. W.

    1972-01-01

    Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

  1. Micro- and nanostructures and their application in gas chromatography.

    PubMed

    Mittermüller, M; Volmer, D A

    2012-07-21

    This mini-review focuses on the latest developments in the field of micro- and nanostructures in gas chromatography (GC). Significant progress has been made in recent years in designing miniaturized structures, for example, structures based on cyclodextrins. These are now commercially available and thus not the topic of this short review. Rather, we concentrate here on on-going research activities on nanoparticles, micro-electromechanical systems (MEMS) and metal-organic framework (MOF) supports as well as state-of-the-art column geometries, with particular emphasis on lab-on-a-chip columns, which undoubtedly will find their way into regular GC developments in the future.

  2. Capillary gas chromatography with two new moderately high temperature phases.

    NASA Technical Reports Server (NTRS)

    Pollock, G. E.

    1972-01-01

    Gas chromatography test results are presented for two new moderately high-temperature phases of Dexsil 400-GC with free hydroxyl end groups (uncapped) and with end groups covered by trimethyl silyl groups (capped). The two Dexsil 400-GC phases were tested for their ability to resolve N-TFA-DL-(+)-2-butyl esters and n-butyl esters, as well as fatty acid methyl esters and hydrocarbon standards. Generally the more polar uncapped phase was superior to the capped phase in all separation comparisons, except for the hydrocarbons.

  3. Capillary gas chromatography with two new moderately high temperature phases.

    NASA Technical Reports Server (NTRS)

    Pollock, G. E.

    1972-01-01

    Gas chromatography test results are presented for two new moderately high-temperature phases of Dexsil 400-GC with free hydroxyl end groups (uncapped) and with end groups covered by trimethyl silyl groups (capped). The two Dexsil 400-GC phases were tested for their ability to resolve N-TFA-DL-(+)-2-butyl esters and n-butyl esters, as well as fatty acid methyl esters and hydrocarbon standards. Generally the more polar uncapped phase was superior to the capped phase in all separation comparisons, except for the hydrocarbons.

  4. Gas-liquid chromatography in lunar organic analysis.

    NASA Technical Reports Server (NTRS)

    Gehrke, C. W.

    1972-01-01

    Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

  5. [Analysis of naphtha vapors in the air by gas chromatography].

    PubMed

    Starek, A; Golba, W

    1984-01-01

    The paper is aimed at the development of a method for determining kerosene vapours in air by gas chromatography. Optimum parameters of kerosenes chromatographic separation and conditions for air sampling were determined. In addition, coefficient of the desorption of kerosene hydrocarbons from charcoal at which they were adsorbed, was determined. The quantitative interpretation of chromatograms was based on the measurement of the peak height of dodecane (C12), which constitutes 10.9% of the preparation mass per cent. The determinability of the method amounts to 60 mg/cm3 for kerosene vapours, with +/- 3,23% precision.

  6. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid...

  7. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid...

  8. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid...

  9. High performance mini-gas chromatography-flame ionization detector system based on micro gas chromatography column

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaofeng; Sun, Jianhai; Ning, Zhanwu; Zhang, Yanni; Liu, Jinhua

    2016-04-01

    Monitoring Volatile organic compounds (VOCs) was a very important measure for preventing environmental pollution, therefore, a mini gas chromatography (GC) flame ionization detector (FID) system integrated with a mini H2 generator and a micro GC column was developed for environmental VOC monitoring. In addition, the mini H2 generator was able to make the system explode from far away due to the abandoned use of a high pressure H2 source. The experimental result indicates that the fabricated mini GC FID system demonstrated high repeatability and very good linear response, and was able to rapidly monitor complicated environmental VOC samples.

  10. High performance mini-gas chromatography-flame ionization detector system based on micro gas chromatography column.

    PubMed

    Zhu, Xiaofeng; Sun, Jianhai; Ning, Zhanwu; Zhang, Yanni; Liu, Jinhua

    2016-04-01

    Monitoring Volatile organic compounds (VOCs) was a very important measure for preventing environmental pollution, therefore, a mini gas chromatography (GC) flame ionization detector (FID) system integrated with a mini H2 generator and a micro GC column was developed for environmental VOC monitoring. In addition, the mini H2 generator was able to make the system explode from far away due to the abandoned use of a high pressure H2 source. The experimental result indicates that the fabricated mini GC FID system demonstrated high repeatability and very good linear response, and was able to rapidly monitor complicated environmental VOC samples.

  11. [Compound preservative and cyclamat determinated by gas chromatography].

    PubMed

    Xin, Ruozhu; Ding, Mei; Zheng, Xianguang; Li, Yajuan

    2008-07-01

    To establish a gas chromatography method for synchronous determination of six preservatives and cyclamat in cake and pastry. The pre-treatment of complicated compound was finished by dialysis cleaning technology. The interference of the complicated foundation body in the cake and pastry was removed by the best dialysis condition: 2 g/L NaOH of dialysis fluid was dialyzed at the temperature of 25 degrees C for 24h, and the six preservatives and cyclamat (sorbic acid, benzoic acid, dehydroacetic acid, ethylparabenum, propylparabenum, butylparabenun and sodium cyclamate) were synchronously seperated by 60-80 mesh Chromosorb WAW DMCS glass packing column of intercoated 5% DEGS + 1% H3 PO4. The seven components in the sample had a good lining relation at the concentration 100 -5000 mg/L when the external standard method was used, and their correlation coefficients were 0.9993-0.9998, and their average recovery rates were 87.5%-101.9%, and their relative standard deviations were 0.64%-3.3%, and detection limits were 1.1-8.8 mg/L. This method could be used to quickly analyse the compound preservatives of the large batch cake and pastry through the common gas chromatography and packed column and this method was simple, accurate and quick.

  12. Measurement of carboxyhaemoglobin by spectrophotometry and gas chromatography.

    PubMed

    Johansson, M B; Wollmer, P

    1989-12-01

    The purpose of this study was to evaluate state-of-the-art spectrophotometry for measurement of carboxyhaemoglobin (COHb). We measured the fractional concentration of COHb in 109 blood samples from patients under investigation of anaemia or with exposure to carbon monoxide (smokers) with the OSM3 Hemoximeter and by gas chromatography. Duplicate measurements were made with both methods in 42 samples. We found only a trivial systematic difference between the two methods. There was, however, a considerable scatter of the measurements, the limits of agreement (95% confidence limits for the difference between the two methods) being -0.98 and 0.86% COHb. The poor agreement between the methods was largely explained by a large random scatter in duplicate spectrophotometric measurements, whereas the method based on gas chromatography was highly reproducible. We conclude that the low accuracy of spectrophotometric measurements of COHb precludes its use for assessment of the endogenous production of CO, but that it may be useful for assessment of exposure to exogenous CO.

  13. Novel stationary phases based on asphaltenes for gas chromatography.

    PubMed

    Boczkaj, Grzegorz; Momotko, Malwina; Chruszczyk, Dorota; Przyjazny, Andrzej; Kamiński, Marian

    2016-07-01

    We present the results of investigations on the possibility of the application of the asphaltene fraction isolated from the oxidized residue from vacuum distillation of crude oil as a stationary phase for gas chromatography. The results of the investigation revealed that the asphaltene stationary phases can find use for the separation of a wide range of volatile organic compounds. The experimental values of Rohrschneider/McReynolds constants characterize the asphaltenes as stationary phases of medium polarity and selectivity similar to commercially available phases based on alkyl phthalates. Isolation of asphaltenes from the material obtained under controlled process conditions allows the production of a stationary phase having reproducible sorption properties and chromatographic columns having the same selectivity. Unique selectivity and high thermal stability make asphaltenes attractive as a material for stationary phases for gas chromatography. A low production cost from a readily available raw material (oxidized petroleum bitumens) is an important economic factor in case of application of the asphaltene stationary phases for preparative and process separations.

  14. Identification of polychlorinated styrene compounds in heron tissues by gas-liquid chromatography-mass spectrometry.

    PubMed

    Reichel, W L; Prouty, R M; Gay, M L

    1977-01-01

    Unknown compounds detected in Ardea herodias tissues are identified by gas-liquid chromatography-mass spectrometry as residues of octachlorostyrene. Heptachlorostyrene and hexachlorostyrene were tentatively identified.

  15. Identification of polychlorinated styrene compounds in heron tissues by gas-liquid chromatography-mass spectrometry

    USGS Publications Warehouse

    Reichel, W.L.; Prouty, R.M.; Gay, M.L.

    1977-01-01

    Unknown compounds detected in Ardea herodias tissues are identified by gas-liquid chromatography-mass spectrometry as residues of octachlorostyrene. Heptachlorostyrene and hexachlorostyrene were tentatively identified.

  16. Validation of a two-dimensional gas chromatography mass spectrometry method for the simultaneous quantification of cannabidiol, Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-THC, and 11-nor-9-carboxy-THC in plasma.

    PubMed

    Karschner, Erin L; Barnes, Allan J; Lowe, Ross H; Scheidweiler, Karl B; Huestis, Marilyn A

    2010-05-01

    A sensitive analytical method for simultaneous quantification of sub-nanogram concentrations of cannabidiol (CBD), Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-THC (11-OH-THC), and 11-nor-9-carboxy-THC (THCCOOH) in plasma is presented for monitoring cannabinoid pharmacotherapy and illicit cannabis use. Analytes were extracted from 1 mL plasma by solid-phase extraction, derivatized with N,O-bis(trimethylsilyl) trifluoroacetamide with 1% trimethylchlorosilane, and analyzed by two-dimensional gas chromatography mass spectrometry (2D-GCMS) with cryofocusing. The lower calibration curve was linear from 0.25-25 ng/mL for CBD and THC, 0.125-25 ng/mL for 11-OH-THC and 0.25-50 ng/mL for THCCOOH. A second higher linear range from 5-100 ng/mL, achieved through modification of injection parameters, was validated for THC, 11-OH-THC, and THCCOOH and was only implemented if concentrations exceeded the lower curve upper limit of linearity. This procedure prevented laborious re-extraction by allowing the same specimen to be re-injected for quantification on the high calibration curve. Intra- and inter-assay imprecision, determined at four quality control concentrations, were or=72.9% for all analytes. Analytes were stable when stored at 22 degrees C for 16 h, 4 degrees C for 48 h, after three freeze-thaw cycles at -20 degrees C and when stored on the autosampler for 48 h. This sensitive and specific 2D-GCMS assay provides a new means of simultaneously quantifying CBD, THC and metabolite biomarkers in clinical medicine, forensic toxicology, workplace drug testing, and driving under the influence of drugs programs.

  17. Using gas chromatography to characterize a direct coal liquefaction naphtha.

    PubMed

    Omais, Badaoui; Courtiade, Marion; Charon, Nadège; Roullet, Christophe; Ponthus, Jérémie; Thiébaut, Didier

    2012-02-24

    Speciation of oxygenated compounds in direct coal liquefaction naphthas is essential considering their important roles in coal conversion reactions. This study attempts to characterize them as fully as possible using gas chromatographic systems. Firstly, GC-MS was deployed allowing the identification of a few ketones, alcohols, and phenols. This conventional analysis was complemented by the application of GC-GC-FID aiming to overcome the coelutions highlighted when using one-dimensional gas chromatography. Heart-cutting and comprehensive two-dimensional gas chromatography were used and the comprehensive system led to better performances as expected considering the complexity of the matrix. In fact, it allowed the identification of more than a hundred of oxygenated compounds belonging to five chemical families: alcohols, ketones, furans, acids and phenols. Average response factors of each of these families were determined by GC×GC-FID using calibration curves and vary from 1 (hydrocarbons) to 2.50 (carboxylic acids). Thanks to a breakthrough columns set involving a trifluoropropyl stationary phase, alcohols and phenols which represent around 14% of the sample were fully identified. A detailed quantification of these species was carried out for the first time in such matrices using the determined response factors. It was concluded that 90% (w/w) of the alcohols are aromatic (phenols), 5% (w/w) are cyclic and 5% (w/w) are linear. A quantification of hydrocarbon families was also achieved and shows that the matrix is mostly naphthenic (56%, w/w), but also contains aromatics (22%, w/w) and paraffins (8%, w/w). This detailed characterization leads to a better understanding of coal conversion processes and is essential to convert them into synthetic fuels. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Flame photometric detection inside of a capillary gas chromatography column.

    PubMed

    Thurbide, Kevin B; Anderson, Christine D

    2003-06-01

    A novel micro-flame photometric detector (FPD) employing a miniature counter-current flame is described. The micro-FPD flame, encompassing a volume of about 30 nL, is operated inside the end of a capillary gas chromatography column (i.e. on-column) or inside of a quartz capillary after the column (i.e. post-column). Either air or oxygen can support a hydrogen flame in the device, although oxygen is far preferable. The detector can be operated for several hours without any observed degradation in performance or flame stability. The optimal gas flows established for the detection of sulfur and phosphorus are in the range of 4 mL min(-1) of oxygen and 9 to 13 mL min(-1) of hydrogen. The fuel-rich micro-FPD flame generates chemiluminescent blue S2* emission for sulfur and green HPO* emission for phosphorus, similar to a conventional FPD. Sulfur response in the micro-FPD is quadratic over nearly 3 orders of magnitude while that of phosphorus is linear over nearly 5 orders of magnitude. The micro-FPD detection limit for sulfur is 1 x 10(-9) g S s(-1), and that of phosphorus is 2 x 10(-10) g P s(-1). The properties established for the initial prototype of the micro-FPD make this counter-current flame method potentially suitable for integration with on-chip gas chromatography or other micro-analytical devices where flame-based detection methods are desirable.

  19. Chemical Discrimination in Turbulent Gas Mixtures with MOX Sensors Validated by Gas Chromatography-Mass Spectrometry

    PubMed Central

    Fonollosa, Jordi; Rodríguez-Luján, Irene; Trincavelli, Marco; Vergara, Alexander; Huerta, Ramón

    2014-01-01

    Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance. PMID:25325339

  20. Chemical discrimination in turbulent gas mixtures with MOX sensors validated by gas chromatography-mass spectrometry.

    PubMed

    Fonollosa, Jordi; Rodríguez-Luján, Irene; Trincavelli, Marco; Vergara, Alexander; Huerta, Ramón

    2014-10-16

    Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  1. Microfabricated planar glass gas chromatography with photoionization detection.

    PubMed

    Lewis, Alastair C; Hamilton, Jacqueline F; Rhodes, Christopher N; Halliday, Jaydene; Bartle, Keith D; Homewood, Philip; Grenfell, Robin J P; Goody, Brian; Harling, Alice M; Brewer, Paul; Vargha, Gergely; Milton, Martin J T

    2010-01-29

    We report the development of a microfabricated gas chromatography system suitable for the separation of volatile organic compounds (VOCs) and compatible with use as a portable measurement device. Hydrofluoric acid etching of 95x95mm Schott B270 wafers has been used to give symmetrical hemi-spherical channels within a glass substrate. Two matching glass plates were subsequently cold bonded with the channels aligned; the flatness of the glass surfaces resulted in strong bonding through van der Waals forces. The device comprised gas fluidic interconnections, injection zone and 7.5 and 1.4m long, 320microm internal diameter capillaries. Optical microscopy confirmed the capillaries to have fully circular channel profiles. Direct column heating and cooling could be achieved using a combination of resistive heaters and Peltier devices. The low thermal conductivity of glass allowed for multiple uniform temperature zones to be achieved within a single glass chip. Temperature control over the range 10-200 degrees C was achieved with peak power demand of approximately 25W. The 7.5m capillary column was static coated with a 2microm film of non-polar dimethylpolysiloxane stationary phase. A standard FID and a modified lightweight 100mW photoionization detector (PID) were coupled to the column and performance tested with gas mixtures of monoaromatic and monoterpene species at the parts per million concentration level. The low power GC-PID device showed good performance for a small set of VOCs and sub ng detection sensitivity to monoaromatics.

  2. Discrimination of n-3 rich oils by gas chromatography.

    PubMed

    Araujo, Pedro; Zeng, Yingxu; Du, Zhen-Yu; Nguyen, Thu-Thao; Frøyland, Livar; Grung, Bjørn

    2010-12-01

    Exploring the capabilities of instrumental techniques for discriminating n-3 rich oils derived from animals is a very important though much neglected area that was emphasized more than 100 years ago. In this study the potential of gas chromatography (GC) for discriminating full fatty acid methyl ester (FAME) profiles from fish (cod liver and salmon) and marine mammal (seal and whale) oils is evaluated by means of principal component analysis (PCA). The FAME profiles from plant oils such as rapeseed, linseed and soy oils and seven different brands of n-3 supplements are also used in the discrimination process. The results from the PCA plots can reliably distinguish between plant, n-3 supplements, fish and marine mammal oils. By removing the contribution of the n-3 supplements and plant oils it is possible to discriminate between types of fish and marine animal oils. GC offers a rapid, simple and convenient means of discriminating oils from different species, brands and grades.

  3. Hansen solubility parameters for polyethylene glycols by inverse gas chromatography.

    PubMed

    Adamska, Katarzyna; Voelkel, Adam

    2006-11-03

    Inverse gas chromatography (IGC) has been applied to determine solubility parameter and its components for nonionic surfactants--polyethylene glycols (PEG) of different molecular weight. Flory-Huggins interaction parameter (chi) and solubility parameter (delta(2)) were calculated according to DiPaola-Baranyi and Guillet method from experimentally collected retention data for the series of carefully selected test solutes. The Hansen's three-dimensional solubility parameters concept was applied to determine components (delta(d), delta(p), delta(h)) of corrected solubility parameter (delta(T)). The molecular weight and temperature of measurement influence the solubility parameter data, estimated from the slope, intercept and total solubility parameter. The solubility parameters calculated from the intercept are lower than those calculated from the slope. Temperature and structural dependences of the entopic factor (chi(S)) are presented and discussed.

  4. [Determination of 2, 4-toluenediamine in urine by gas chromatography].

    PubMed

    Zhang, Wan-chao; Liu, Bao-feng; Liu, Hui; Miao, Rong-ming

    2013-12-01

    To establish a method for determining the content of 2,4-toluenediamine, a urinary metabolite of toluene diisocyanate, by gas chromatography. Urine samples were collected, and acidification, extraction, derivatization, separation with a capillary column, and detection with an electron capture detector were performed. The target compound was qualified by retention time and quantified by peak area. The concentration of 2, 4-toluenediamine showed a linear relationship with peak area within 0.0∼40 ng/ml, with a correlation coefficient 0.9995; the limit of detection was 0.44 ng/ml, the lower limit of quantification was 1.47 ng/ml, the relative standard deviation was 1.85%∼4.05%; the recovery rate was 97.98%∼99.28%. The method has the advantages of high sensitivity and high accuracy and can be used for determination of 2, 4-toluenediamine in urine.

  5. Low thermal mass gas chromatography: principles and applications.

    PubMed

    Luong, Jim; Gras, Ronda; Mustacich, Robert; Cortes, Hernan

    2006-01-01

    In gas chromatography (GC), temperature programming is often considered to be the second most important parameter to control, the first being column selectivity. A radically new GC technology to achieve ultrafast temperature programming with an unprecedented cool down time and low power consumption has recently become available. This technology is referred to as low thermal mass GC (LTMGC). Though the technology has its roots in resistive heating, which forms the basis of principle and design concept, the approach taken to achieve ultrafast heating and cool down time by LTMGC represents a significant break-through in GC. Despite some rectifiable shortcomings, LTMGC has proven to be an ideal methodology to deliver near/real time GC data, high precision, and high throughput applications. It is a new approach for modern high-speed GC. This paper documents the fundamental design principles behind LTMGC, performance data, and examples of applications investigated.

  6. Possibility of diagnosing meningitis by gas chromatography: cryptococcal meningitis.

    PubMed Central

    Schlossberg, D; Brooks, J B; Shulman, J

    1976-01-01

    Cerebrospinal fluid (CSF) from eight patients with cryptococcal meningitis, from ten patients with viral meningitis, and from four control patients without meningitis were analyzed by electron-capture gas-liquid chromatography (EC-GLC). All cryptococcal specimens had similar EC-GLC profiles, and these differed from those of the controls. Viral EC-GLC patterns were different from those obtained with specimens from the patients with cryptococcal infection and from the controls. In addition, specimens from patients with various types of viral infections gave profiles that differed from each other. Two normal CSFs were inoculated with Cryptococcus neoformans; aliquots of these cultures showed an EC-GLC pattern very similar to that seen in CSF of patients with cryptococcal meningitis. The EC-GLC procedure is rapid, reproducible, and easy to perform and may hold promise as an additional aid in the diagnosis of cryptococcal infection. PMID:773956

  7. Field gas chromatography-mass spectrometry for fast analysis.

    PubMed

    Makas, Alexei L; Troshkov, Mikhail L

    2004-02-05

    The objective of this presentation is to demonstrate the original device and procedure for fast gas chromatography-mass spectrometry (GC-MS) analysis of gaseous and liquid samples and to discuss its features and capabilities. The concept was developed in order to expand the range of compounds suitable for GC separation and to reduce the time of analysis. Field GC-MS, consisting of original "concentrator-thermodesorber" (CTD) unit, multiple module GC system and compact magnetic mass spectrometer with powerful two-stage vacuum system and multicollector ion detector, is represented. The whole weight of the device is 90 kg. Power consumption is 250 W. The device and analytical procedures allow high speed screening of toxic substances in air and extracts within 100 s per sample. The examples of applications are described, including fast screening of tributyl phosphate (TBP) in air at low ppt level at the rate 1 sample/min.

  8. Design, testing, and simulation of microscale gas chromatography columns

    SciTech Connect

    Hudson, M.L.; Kottenstette, R.; Matzke, C.M.; Frye-Mason, G.C.; Shollenberger, K.A.; Adkins, D.R.; Wong, C.C.

    1998-08-01

    A microscale gas chromatography column is one component in a microscale chemistry laboratory for detecting chemical agents. Several columns were fabricated using the Bosch etch process which allows deep, high aspect ratio channels of rectangular cross-section. A design tool, based on analytical models, was developed to evaluate the effects of operating conditions and column specifications on separation resolution and time. The effects of slip flow, channel configuration, and cross-sectional shape were included to evaluate the differences between conventional round, straight columns and the microscale rectangular, spiral columns. Experimental data were obtained and compared with the predicted flowrates and theoretical number of plates. The design tool was then employed to select more optimum channel dimensions and operating conditions for high resolution separations.

  9. A simple parallel gas chromatography column screening system.

    PubMed

    Schafer, Wes; Hamilton, Simon E; Pirzada, Zainab; Welch, Christopher J

    2012-01-01

    A simple approach to the automated screening of four different columns on a single gas chromatography (GC) instrument is used for rapid chiral GC method development. Configuration of a conventional GC instrument with a second autosampler and several inexpensive Y-splitters enables simultaneous evaluation of two different columns, allowing a total of four different columns to be evaluated in two automated back to back runs. The resulting system affords a simple and effective approach to chiral GC method development that speeds analysis while eliminating the need for slow and tedious manual interchange of columns. An example of developing a rapid isothermal GC method from the screening results obtained by the instrument is also shown. Copyright © 2011 Wiley-Liss, Inc.

  10. Estimation of brassylic acid by gas chromatography-mass spectrometry

    SciTech Connect

    Mohammed J. Nasrullah, Erica N. Pfarr, Pooja Thapliyal, Nicholas S. Dusek, Kristofer L. Schiele, Christy Gallagher-Lein, and James A. Bahr

    2010-10-29

    The main focus of this work is to estimate Brassylic Acid (BA) using gas chromatography-mass spectrometry (GC-MS). BA is a product obtained from the oxidative cleavage of Erucic Acid (EA). BA has various applications for making nylons and high performance polymers. BA is a 13 carbon compound with two carboxylic acid functional groups at the terminal end. BA has a long hydrocarbon chain that makes the molecule less sensitive to some of the characterization techniques. Although BA can be characterized by NMR, both the starting material (EA) and products BA and nonanoic acid (NA) have peaks at similar {delta}, ppm values. Hence it becomes difficult for the quick estimation of BA during its synthesis.

  11. Quantification of antidepressants using gas chromatography-mass spectrometry.

    PubMed

    Winecker, Ruth E

    2010-01-01

    Antidepressants are of great interest to clinical and forensic toxicologists as they are frequently used in suicidal gestures; they can be the source of drug interactions and some have narrow therapeutic indices making the potential for toxicity more likely. There are five categories of antidepressants based on function and/or structure. These are monoamine oxidase inhibitors (MAOI), cyclic antidepressants including tricyclic and tetracyclic compounds (TCA), selective serotonin reuptake inhibitors (SSRI), serotonin-norepinephrine reuptake inhibitors (SNRI), and atypical compounds. This method is designed to detect the presence of antidepressant drugs in blood/serum, urine, and tissue specimens using gas chromatography/mass spectrometry (GC/MS) following liquid-liquid extraction (LLE) and identified by relative retention times and mass spectra.

  12. Site-Specific Cryo-focused Ion Beam Sample Preparation Guided by 3D Correlative Microscopy

    PubMed Central

    Arnold, Jan; Mahamid, Julia; Lucic, Vladan; de Marco, Alex; Fernandez, Jose-Jesus; Laugks, Tim; Mayer, Tobias; Hyman, Anthony A.; Baumeister, Wolfgang; Plitzko, Jürgen M.

    2016-01-01

    The development of cryo-focused ion beam (cryo-FIB) for the thinning of frozen-hydrated biological specimens enabled cryo-electron tomography (cryo-ET) analysis in unperturbed cells and tissues. However, the volume represented within a typical FIB lamella constitutes a small fraction of the biological specimen. Retaining low-abundance and dynamic subcellular structures or macromolecular assemblies within such limited volumes requires precise targeting of the FIB milling process. In this study, we present the development of a cryo-stage allowing for spinning-disk confocal light microscopy at cryogenic temperatures and describe the incorporation of the new hardware into existing workflows for cellular sample preparation by cryo-FIB. Introduction of fiducial markers and subsequent computation of three-dimensional coordinate transformations provide correlation between light microscopy and scanning electron microscopy/FIB. The correlative approach is employed to guide the FIB milling process of vitrified cellular samples and to capture specific structures, namely fluorescently labeled lipid droplets, in lamellas that are 300 nm thick. The correlation procedure is then applied to localize the fluorescently labeled structures in the transmission electron microscopy image of the lamella. This approach can be employed to navigate the acquisition of cryo-ET data within FIB-lamellas at specific locations, unambiguously identified by fluorescence microscopy. PMID:26769364

  13. Site-Specific Cryo-focused Ion Beam Sample Preparation Guided by 3D Correlative Microscopy.

    PubMed

    Arnold, Jan; Mahamid, Julia; Lucic, Vladan; de Marco, Alex; Fernandez, Jose-Jesus; Laugks, Tim; Mayer, Tobias; Hyman, Anthony A; Baumeister, Wolfgang; Plitzko, Jürgen M

    2016-02-23

    The development of cryo-focused ion beam (cryo-FIB) for the thinning of frozen-hydrated biological specimens enabled cryo-electron tomography (cryo-ET) analysis in unperturbed cells and tissues. However, the volume represented within a typical FIB lamella constitutes a small fraction of the biological specimen. Retaining low-abundance and dynamic subcellular structures or macromolecular assemblies within such limited volumes requires precise targeting of the FIB milling process. In this study, we present the development of a cryo-stage allowing for spinning-disk confocal light microscopy at cryogenic temperatures and describe the incorporation of the new hardware into existing workflows for cellular sample preparation by cryo-FIB. Introduction of fiducial markers and subsequent computation of three-dimensional coordinate transformations provide correlation between light microscopy and scanning electron microscopy/FIB. The correlative approach is employed to guide the FIB milling process of vitrified cellular samples and to capture specific structures, namely fluorescently labeled lipid droplets, in lamellas that are 300 nm thick. The correlation procedure is then applied to localize the fluorescently labeled structures in the transmission electron microscopy image of the lamella. This approach can be employed to navigate the acquisition of cryo-ET data within FIB-lamellas at specific locations, unambiguously identified by fluorescence microscopy. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  14. [Analysis of the phthalates in cosmetics by capillary gas chromatography].

    PubMed

    Chen, Huiming; Wang, Chao; Wang, Xing

    2004-05-01

    A capillary gas chromatographic method with flame ionization detector (GC-FID) for the detection of the six phthalates (dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), di(2-ethylhexyl) phthalate (DEHP), di-n-octyl phthalate (DOP)) in the cosmetics was developed. The phthalates were extracted from cosmetics with methanol under ultrasonication and then separated with high-speed centrifugation. The supernatant was dehydrated and filtrated through membrane with 0.5 microm pore diameter. The filtrate was injected into the GC system for analysis. Then the positive results observed in the GC-FID chromatogram were confirmed by gas chromatography-electron impact-mass detection (GC-EI-MS) analysis. Retention times of the peaks could be applied for qualitative analysis. External standard method was used for quantitative analysis. The recoveries of the six phthalates were between 82.90% and 109.50%. The relative standard deviations were between 2.1% and 4.6%. The detection limits of the method were: 0.1 ng for DMP, DEP, DBP and BBP, and 0.5 ng for DEHP and DOP, respectively. The method presented the advantages of high precision, high sensitivity, small sample size, and simple pretreatment. The method can be used to test the six phthalates in the cosmetics.

  15. Recent advances and applications of gas chromatography vacuum ultraviolet spectroscopy.

    PubMed

    Santos, Inês C; Schug, Kevin A

    2017-01-01

    The vacuum ultraviolet spectrophotometer was developed recently as an alternative to existing gas chromatography detectors. This detector measures the absorption of gas-phase chemical species in the range of 120-240 nm, where all chemical compounds present unique absorption spectra. Therefore, qualitative analysis can be performed and quantification follows standard Beer-Lambert law principles. Different fields of application, such as petrochemical, food, and environmental analysis have been explored. Commonly demonstrated is the capability for facile deconvolution of co-eluting analytes. The concept of additive absorption for co-eluting analytes has also been advanced for classification and speciation of complex mixtures using a data treatment procedure termed time interval deconvolution. Furthermore, pseudo-absolute quantitation can be performed for system diagnosis, as well as potentially calibrationless quantitation. In this manuscript an overview of these features, the vacuum ultraviolet spectrophotometer instrumentation, and performance capabilities are given. A discussion of the applications of the vacuum ultraviolet detector is provided by describing and discussing the papers published thus far since 2014. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Gas phase chromatography of halides of elements 104 and 105

    SciTech Connect

    Tuerler, A.; Gregorich, K.E.; Czerwinski, K.R.; Hannink, N.J.; Henderson, R.A.; Hoffman, D.C.; Kacher, C.D.; Kadkhodayan, B.; Kreek, S.A.; Lee, D.M.; Leyba, J.D.; Nurmia, M.J. ); Gaeggeler, H.W.; Jost, D.T.; Kovacs, J.; Scherer, U.W.; Vermeulen, D.; Weber, A. , Villigen ); Barth, H.; Gober, M.K.; Kratz, J.V. (Philipps-Univ., Marburg

    1991-04-01

    On-line isothermal gas phase chromatography was used to study halides of {sup 261}104 (T{sub {1/2}} = 65 s) and {sup 262,263}105 (T{sub {1/2}} = 34 s and 27 s) produced an atom-at-a time via the reactions {sup 248}Cm({sup 18}O, 5n) and {sup 249}Bk({sup 18}O, 5n, 4n), respectively. Using HBr and HCl gas as halogenating agents, we were able to produce volatile bromides and chlorides of the above mentioned elements and study their behavior compared to their lighter homologs in Groups 4 or 5 of the periodic table. Element 104 formed more volatile bromides than its homolog Hf. In contrast, element 105 bromides were found to be less volatile than the bromides of the group 5 elements Nb and Ta. Both 104 and Hf chlorides were observed to be more volatile than their respective bromides. 31 refs., 8 figs.

  17. Analysis of odour compounds from scented consumer products using gas chromatography-mass spectrometry and gas chromatography-olfactometry.

    PubMed

    Bartsch, Jennifer; Uhde, Erik; Salthammer, Tunga

    2016-01-21

    Scented consumer products are being bought in increasing amounts and gaining more popularity. There is, however, relatively little information available about their ingredients, emissions and allergenic potential. Frequently, a mixture of different fragrance substances and not solely an individual substance contributes to the overall desired smell. The aim of this study was to investigate the odorous volatile organic compounds (OVOCs) in consumer products containing fragrances. Over 44 products were selected: various scented candles, printing products with different scent types and other products types particularly meant to be used indoors. Measurements were carried out in a desiccator. Air samples were collected on thermal desorption tubes to determine the released fragrance substances by means of gas chromatography-mass spectrometry (GC-MS). Moreover, gas chromatography-olfactometry (GC-O) was used to obtain sensory data and to ensure no important odorant was overlooked. Using both methods it was possible to distinguish between odour active and inactive compounds and subsequently to identify almost 300 different odorants across all scented products. Besides the advantage of differentiation, as the human nose is a very sensitive detector, GC-O was found to be a useful tool for detecting traces and chosen target compounds. One focus in this study lay on the 26 EU-regulated fragrance allergens to prove their relevance in scented consumer goods. In total, 18 of them were identified, with at least one substance being present in almost every product. Benzyl alcohol, cinnamaldehyde, citronellol, eugenol, linalool and limonene were the prevalently detected allergens. Particularly linalool and limonene were observed in over 50% of the products. In addition, eugenol appeared to be one of the most frequently detected compounds in trace-level concentrations in the candle emissions.

  18. Identification of New Metabolites of Bacterial Transformation of Indole by Gas Chromatography-Mass Spectrometry and High Performance Liquid Chromatography

    PubMed Central

    Arora, Pankaj Kumar

    2014-01-01

    Arthrobacter sp. SPG transformed indole completely in the presence of an additional carbon source. High performance liquid chromatography and gas chromatography-mass spectrometry detected indole-3-acetic acid, indole-3-glyoxylic acid, and indole-3-aldehyde as biotransformation products. This is the first report of the formation of indole-3-acetic acid, indole-3-glyoxylic acid, and indole-3-aldehyde from indole by any bacterium. PMID:25548566

  19. [Analytical method and comparison for static and dynamic headspace gas chromatography of anisole in water].

    PubMed

    Zhang, Yan; Qian, Jie-feng; Liu, Lan-xia; Zhao, Hui-qin

    2013-01-01

    To establish and compare the method of static headspace gas chromatography hydrogen flame detector (static headspace method) and purge and trap gas chromatography-mass spectrometry (dynamic headspace method) of anisole in water. Nitrogen gas was used as carrier gas in the static headspace method, 5 g NaCl as matrix modifier was added into 10 ml water. The sample was balanced with high speed vibration at 75°C for 30 min, and anisole was detected by gas chromatography and quantified with external standard. Helium was used as carrier gas in dynamic headspace method, 5.0 ml water and 0.004 mg/L internal standard fluorobenzene was purged into the purge and trap apparatus. After purging, trapping and desorption, anisole was detected by the gas chromatography-mass spectrograph, confirmed by the retention time and comparison of mass-spectrogram in spectrum library and quantified with internal standard. The repeatability and sensitivity of assay were evaluated. A good linear range for anisole was observed in static headspace gas chromatography and dynamic headspace gas chromatography-mass spectrometry, within the range of 10 - 500 µg/L and 0.5 - 60.0 µg/L respectively. The linear regression equation was Y = 782.150X + 1.3446 and Y = 0.0358X - 0.0209 respectively, both the correlation coefficient ≥ 0.999. The detection limit (LOD) were 0.002 µg/L and 0.110 µg/L, the lower limit of quantitation (LOQ) were 0.006 µg/L and 0.350 µg/L, the relative standard deviation (RSD) were 1.8% - 2.3% and 2.0% - 3.4%, and the spiking recovery were 93% - 101% and 96% - 101% respectively. The methods of static headspace gas chromatography and dynamic headspace gas chromatography-mass spectrometry are simple and can measure anisole in water quickly, sensitively and accurately.

  20. Online Continuous Trace Process Analytics Using Multiplexing Gas Chromatography.

    PubMed

    Wunsch, Marco R; Lehnig, Rudolf; Trapp, Oliver

    2017-04-04

    The analysis of impurities at a trace level in chemical products, nutrition additives, and drugs is highly important to guarantee safe products suitable for consumption. However, trace analysis in the presence of a dominating component can be a challenging task because of noncompatible linear detection ranges or strong signal overlap that suppresses the signal of interest. Here, we developed a technique for quantitative analysis using multiplexing gas chromatography (mpGC) for continuous and completely automated process trace analytics exemplified for the analysis of a CO2 stream in a production plant for detection of benzene, toluene, ethylbenzene, and the three structural isomers of xylene (BTEX) in the concentration range of 0-10 ppb. Additional minor components are methane and methanol with concentrations up to 100 ppm. The sample is injected up to 512 times according to a pseudorandom binary sequence (PRBS) with a mean frequency of 0.1 Hz into a gas chromatograph equipped with a flame ionization detector (FID). A superimposed chromatogram is recorded which is deconvoluted into an averaged chromatogram with Hadamard transformation. Novel algorithms to maintain the data acquisition rate of the detector by application of Hadamard transformation and to suppress correlation noise induced by components with much higher concentrations than the target substances are shown. Compared to conventional GC-FID, the signal-to-noise ratio has been increased by a factor of 10 with mpGC-FID. Correspondingly, the detection limits for BTEX in CO2 have been lowered from 10 to 1 ppb each. This has been achieved despite the presence of detectable components (methane and methanol) with a concentration about 1000 times higher than the target substances. The robustness and reliability of mpGC has been proven in a two-month field test in a chemical production plant.

  1. Chromatography.

    ERIC Educational Resources Information Center

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  2. Chromatography.

    ERIC Educational Resources Information Center

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  3. Polyimide polymer glass-free capillary columns for gas chromatography.

    PubMed

    Webster, Jackie G; Marine, Susan S; Danielson, Neil D

    2011-01-01

    Polymeric polyimide capillary tubing, both uncoated and coated with stationary phases of two polarities, is explored for use as capillary columns for gas chromatography (GC). These glass-free polyimide columns are flexible and their small winding diameter of less than a cm around a solid support makes them compatible for potential use in portable GC instruments. Polyimide columns with dimensions of 0.32 mm i.d. × 3 m are cleaned, annealed at 300°C, and coated using the static method with phenylmethylsilicone (PMS). Separations of volatile organics are investigated isothermally on duplicate sets of polyimide columns by GC with a flame ionization detector using split injection. Unlike the uncoated ones, the coated polyimide columns successfully separate Grob test mix classes of alkanes, amines, and fatty acid methyl esters. The relative standard deviations for retention time and peak area are 0.5 and 2.5 , respectively. With the 3 m PMS-coated column connected to a retention gap to permit operation at its optimum flow rate of 30 cm/s, a plate count of 3200 or plate height of 1 mm is possible. Lack of retention and tailing peaks are evident for the polyimide polymer capillary columns as compared to that of a 3 m commercial cross-linked PMS fused silica capillary. However, headspace analyses of an aromatic hydrocarbon mix and a Clearcoat automotive paint sample are viable applications on the PMS polyimide polymer column.

  4. Discrimination of n-3 Rich Oils by Gas Chromatography

    PubMed Central

    Zeng, Yingxu; Du, Zhen-Yu; Nguyen, Thu-Thao; Frøyland, Livar; Grung, Bjørn

    2010-01-01

    Exploring the capabilities of instrumental techniques for discriminating n-3 rich oils derived from animals is a very important though much neglected area that was emphasized more than 100 years ago. In this study the potential of gas chromatography (GC) for discriminating full fatty acid methyl ester (FAME) profiles from fish (cod liver and salmon) and marine mammal (seal and whale) oils is evaluated by means of principal component analysis (PCA). The FAME profiles from plant oils such as rapeseed, linseed and soy oils and seven different brands of n-3 supplements are also used in the discrimination process. The results from the PCA plots can reliably distinguish between plant, n-3 supplements, fish and marine mammal oils. By removing the contribution of the n-3 supplements and plant oils it is possible to discriminate between types of fish and marine animal oils. GC offers a rapid, simple and convenient means of discriminating oils from different species, brands and grades. PMID:20963508

  5. Gas-liquid chromatography of fecal neutral steriods.

    PubMed

    Gerhardt, K O; Gehrke, C W; Rogers, I T; Flynn, M A; Hentges, D J

    1977-05-21

    A method is described for the analysis of fecal neutral steriods with a dual-column gas-liquid chromatography (GLC) system. After saponification of the fecal slurry, the neutral steroids were extracted with hexane. The GLC separation of the compounds and quantitation were achieved by simultaneous injection of the derivatized and derivatized aliquots of the extract onto dual colmuns under identical conditions. The neutral steroids of interest were than identified by matching the retention times with those of known standards, and identification was confirmed by use of an interfaced GLC high-resolution mass spectrometry system. The detection limit was 0.003 mg of steroid/g of fecal slurry. The pricision of the method is illustrated by a relative standard diviation of 2-10% and a recovery of neutral steroids from 73-96%. The method was applied to the determination of fecal neutral steroids in a "High protein diet in colon cancer study". A considerably larger level of coprostanone than of coprostanol was observed. Data on neutral steroids in fecal samples from subjects on different diets are the subject of a separate publication.

  6. Fully Automated Portable Comprehensive 2-Dimensional Gas Chromatography Device.

    PubMed

    Lee, Jiwon; Zhou, Menglian; Zhu, Hongbo; Nidetz, Robert; Kurabayashi, Katsuo; Fan, Xudong

    2016-10-06

    We developed a fully automated portable 2-dimensional (2-D) gas chromatography (GC x GC) device, which had a dimension of 60 cm × 50 cm × 10 cm and weight less than 5 kg. The device incorporated a micropreconcentrator/injector, commercial columns, micro-Deans switches, microthermal injectors, microphotoionization detectors, data acquisition cards, and power supplies, as well as computer control and user interface. It employed multiple channels (4 channels) in the second dimension ((2)D) to increase the (2)D separation time (up to 32 s) and hence (2)D peak capacity. In addition, a nondestructive flow-through vapor detector was installed at the end of the (1)D column to monitor the eluent from (1)D and assist in reconstructing (1)D elution peaks. With the information obtained jointly from the (1)D and (2)D detectors, (1)D elution peaks could be reconstructed with significantly improved (1)D resolution. In this Article, we first discuss the details of the system operating principle and the algorithm to reconstruct (1)D elution peaks, followed by the description and characterization of each component. Finally, 2-D separation of 50 analytes, including alkane (C6-C12), alkene, alcohol, aldehyde, ketone, cycloalkane, and aromatic hydrocarbon, in 14 min is demonstrated, showing the peak capacity of 430-530 and the peak capacity production of 40-80/min.

  7. An improved multiple flame photometric detector for gas chromatography.

    PubMed

    Clark, Adrian G; Thurbide, Kevin B

    2015-11-20

    An improved multiple flame photometric detector (mFPD) is introduced, based upon interconnecting fluidic channels within a planar stainless steel (SS) plate. Relative to the previous quartz tube mFPD prototype, the SS mFPD provides a 50% reduction in background emission levels, an orthogonal analytical flame, and easier more sensitive operation. As a result, sulfur response in the SS mFPD spans 4 orders of magnitude, yields a minimum detectable limit near 9×10(-12)gS/s, and has a selectivity approaching 10(4) over carbon. The device also exhibits exceptionally large resistance to hydrocarbon response quenching. Additionally, the SS mFPD uniquely allows analyte emission monitoring in the multiple worker flames for the first time. The findings suggest that this mode can potentially further improve upon the analytical flame response of sulfur (both linear HSO, and quadratic S2) and also phosphorus. Of note, the latter is nearly 20-fold stronger in S/N in the collective worker flames response and provides 6 orders of linearity with a detection limit of about 2.0×10(-13)gP/s. Overall, the results indicate that this new SS design notably improves the analytical performance of the mFPD and can provide a versatile and beneficial monitoring tool for gas chromatography. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Gas chromatography-mass spectrometry of biofluids and extracts.

    PubMed

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Yang, Yang; Kharbatia, Najeh M

    2015-01-01

    Gas chromatography-mass spectrometry (GC-MS) has been widely used in metabonomics analyses of biofluid samples. Biofluids provide a wealth of information about the metabolism of the whole body and from multiple regions of the body that can be used to study general health status and organ function. Blood serum and blood plasma, for example, can provide a comprehensive picture of the whole body, while urine can be used to monitor the function of the kidneys, and cerebrospinal fluid (CSF) will provide information about the status of the brain and central nervous system (CNS). Different methods have been developed for the extraction of metabolites from biofluids, these ranging from solvent extracts, acids, heat denaturation, and filtration. These methods vary widely in terms of efficiency of protein removal and in the number of metabolites extracted. Consequently, for all biofluid-based metabonomics studies, it is vital to optimize and standardize all steps of sample preparation, including initial extraction of metabolites. In this chapter, recommendations are made of the optimum experimental conditions for biofluid samples for GC-MS, with a particular focus on blood serum and plasma samples.

  9. Fast comprehensive two-dimensional gas chromatography with cryogenic modulation.

    PubMed

    Junge, Melanie; Bieri, Stefan; Huegel, Helmut; Marriott, Philip J

    2007-06-15

    The fast separation of a mixture of 29 compounds by using comprehensive two-dimensional gas chromatography is reported. Capillary column sets with shorter lengths and smaller inner diameter in both the first and second dimensions have been tested, for both fast chiral and achiral separations. Fast chiral separations, which included enantiomer separations of limonene, linalool, citronellol, and alpha-isomethylionone, were achieved within 23 min, which corresponds to approximately 2-fold faster than analyses under conditions previously considered as normal. Fast achiral separations, which do not have the restriction of requiring a minimum quality of chiral resolution, were obtained within 5 min, which is markedly faster than separations on the normal column set under conditions more commonly employed. The achiral fast GC x GC method used a 5 m x 0.1 mm i.d. first dimension column, interfaced to a 0.3 m x 0.05 mm i.d. second column, with temperature program rate of 35 degrees C.min-1; a modulation period of 1 s was employed. Peak widths at baseline on the first column were a little over 1 s, while modulated peak widths at half-height recorded with a flame ionization detector operating at 200 Hz were approximately 30 ms. The benefits and limitations of GC x GC for fast chiral and achiral separations are reported and discussed.

  10. Comprehensive two-dimensional gas chromatography with pattern modulation.

    PubMed

    Seeley, John V; Seeley, Stacy K

    2015-11-20

    Comprehensive two-dimensional gas chromatography (GC×GC) modulators normally transfer primary column effluent to the head of the secondary column as a series of sharp pulses. Such pulses are produced with time-varying temperature gradients in thermal modulation or with time-varying flow patterns in flow modulation. Thermal modulators produce narrow peaks at optimal flow rates, but require large amounts of consumables or a highly engineered heating/cooling system. Flow modulators involve simpler hardware and no additional consumables. However, flow modulators require a large increase in secondary column flow or transfer only a small portion of the primary effluent to the secondary column. This study examines a new method of producing GC×GC separations with a flow modulator. Instead of injecting narrow pulses, the modulator transfers primary effluent to the secondary column in the form of an intricate injection pattern. The detector signal is deconvoluted and converted to a two-dimensional chromatogram. The high duty cycle of the technique (>50%) leads to deconvoluted peaks with twenty times greater intensity than those produced by conventional modulation with a Deans switch modulator. Pattern modulation can be produced without requiring elevated carrier flows. This study evaluates the efficacy of pattern modulation GC×GC by analyzing a standard mixture of 43 oxygenated organic compounds and an E85 fuel sample. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. [Determination of dimethyl ether correction factors in gas chromatography with TCD and FID].

    PubMed

    Chen, J; Zhang, L; Yang, L; Cai, G

    1997-05-01

    Dimethyl ether (DME) correction factors in gas chromatography with thermal conductivity detector (TCD) and flame ionization detector (FID) by using H2 as carrier gas were determined in this work. The homemade DME gas was quantitatively absorbed in ice-cold water. With ethanol as standard, the aqueous mixture was injected into a gas chromatograph, equipped with serially-connected TCD and FID. The weight correction factors of DME based on methanol were 0.86 and 0.55 for TCD and FID respectively. The result for TCD was also confirmed by calculation based on the stoichiometrical transformation of methanol into DME in reaction gas chromatography.

  12. [Analysis of cracking gas compressor fouling by pyrolysis gas chromatography-mass spectrometry].

    PubMed

    Hu, Yunfeng; Fang, Fei; Wei, Tao; Liu, Shuqing; Jiang, Guangshen; Cai, Jun

    2013-06-01

    The fouling from the different sections of the cracked gas compressor in Daqing Petrochemical Corporation was analyzed by pyrolysis gas chromatography-mass spectrometry (Py/GC-MS). All the samples were cracked in RJ-1 tube furnace cracker at the cracking temperature of 500 degrees C, and separated with a 60 m DB-1 capillary column. An electron impact ionization (EI) source was used with the ionizing voltage of 70 eV. The results showed the formation of fouling was closely related with cyclopentadiene which accounted for about 50% of the cracking products. Other components detected were 1-butylene, propylene, methane and n-butane. This Py/GC-MS method can be used as an effective approach to analyze the causes of fouling in the petrochemical plants.

  13. Multiresidue analysis of pesticides in soil by gas chromatography with nitrogen-phosphorus detection and gas chromatography mass spectrometry.

    PubMed

    Fenoll, José; Hellín, Pilar; Marín, Cristóbal; Martínez, Carmen M; Flores, Pilar

    2005-10-05

    A rapid multiresidue method for the simultaneous determination of 25 fungicides and insecticides in soil was developed. Soil samples are extracted by sonication with a water-acetonitrile mixture, and the pesticides are partitioned into dichloromethane. Final determination was made by gas chromatography (GC) with nitrogen-phosphorus detection (NPD). Confirmation analysis of pesticides was carried out by GC-MS in the selected ion monitoring (SIM) mode. The identification of compounds was based on retention time and on comparison of the primary and secondary ions. The average recovery by the GC-NPD method obtained for these compounds varied from 68.5% to 112.1% with a relative standard deviation between 1.8% and 6.2%. The GC-NPD method presents good linearity over the range assayed 50-2000 microg/L, and the detection limit for the pesticides studied varied from 0.1 to 10.4 microg/kg. The proposed method was used to determine pesticide levels in soil samples from experimental greenhouse pepper cultivation.

  14. DIRECT-DEPOSITION INFRARED SPECTROMETRY WITH GAS AND SUPERCRITICAL FLUID CHROMATOGRAPHY

    EPA Science Inventory

    A direct-deposition Fourier transform infrared (FT-IR) system has been evaluated for applicability to gas chromatography (GC) and supercritical fluid chromatography (SFC) of environmental analytes. A 100-um i.d. fused-silica transfer line was used for GC, and a 50-um transfer lin...

  15. DIRECT-DEPOSITION INFRARED SPECTROMETRY WITH GAS AND SUPERCRITICAL FLUID CHROMATOGRAPHY

    EPA Science Inventory

    A direct-deposition Fourier transform infrared (FT-IR) system has been evaluated for applicability to gas chromatography (GC) and supercritical fluid chromatography (SFC) of environmental analytes. A 100-um i.d. fused-silica transfer line was used for GC, and a 50-um transfer lin...

  16. Separation of stereoisomers of several furan derivatives by capillary gas chromatography-mass spectrometry, supercritical fluid chromatography, and liquid chromatography using chiral stationary phases.

    PubMed

    Kasai, Hiroko F; Tsubuki, Masayoshi; Takahashi, Kazunori; Shirao, Mika; Matsumoto, Yohichiro; Honda, Toshio; Seyama, Yoshiyuki

    2002-11-15

    The direct separation of several stereoisomers (enantiomers and geometrical isomers) of furan derivatives, important intermediates for the synthesis of physiologically active natural products, was achieved using capillary gas chromatography/mass spectrometry with a per-O-methyl-beta-cyclodextrin, supercritical fluid chromatography and high-performance liquid chromatography with a tris(3,5-dimethylphenylcarbamate) of cellulose or amylose for the chiral stational phases, respectively. The temperature dependence of the peak resolution (Rs) and the retention factor (k) over the range of 110-130 degrees was studied using crotyl furfuryl ether in gas chromatography. Successive increases in the Rs value and of the difference between the k value of the E-isomer and the k value of the Z-isomer were observed when the gradient temperature was decreased. The per-O-methyl-beta-cyclodextrin column was suitable for use with volatile furan ethers whose molecular masses are between 150 and 180. In conclusion, the separation of thermally unstable furan derivatives was accomplished using supercritical fluid chromatography and high-performance liquid chromatography.

  17. DETERMINATION OF CHLOROETHENES IN ENVIRONMENTAL BIOLOGICAL SAMPLES USING GAS CHROMATOGRAPHY COUPLED WITH SOLID PHASE MICRO EXTRACTION

    EPA Science Inventory

    An analytical method has been developed to determine the chloroethene series, tetrachloroethene (PCE), trichloroethene (TCE),cisdichloroethene (cis-DCE) andtransdichloroethene (trans-DCE) in environmental biotreatment studies using gas chromatography coupled with a solid phase mi...

  18. Chemical Composition of Latent Fingerprints by Gas Chromatography-Mass Spectrometry

    ERIC Educational Resources Information Center

    Hartzell-Baguley, Brittany; Hipp, Rachael E.; Morgan, Neal R.; Morgan, Stephen L.

    2007-01-01

    An experiment in which gas chromatography-mass spectrometry (GC-MS) is used for latent fingerprint extraction and analysis on glass beads or glass slides is conducted. The results determine that the fingerprint residues are gender dependent.

  19. Analysis of chemical signals in red fire ants by gas chromatography and pattern recognition techniques

    USDA-ARS?s Scientific Manuscript database

    The combination of gas chromatography and pattern recognition (GC/PR) analysis is a powerful tool for investigating complicated biological problems. Clustering, mapping, discriminant development, etc. are necessary to analyze realistically large chromatographic data sets and to seek meaningful relat...

  20. ENVIRONMENTAL ANALYSIS BY AB INITIO QUANTUM MECHANICAL COMPUTATION AND GAS CHROMATOGRAPHY/FOURIER TRANSFORM INFRARED SPECTROMETRY.

    EPA Science Inventory

    Computational chemistry, in conjunction with gas chromatography/mass spectrometry/Fourier transform infrared spectrometry (GC/MS/FT-IR), was used to tentatively identify seven tetrachlorobutadiene (TCBD) isomers detected in an environmental sample. Computation of the TCBD infrare...

  1. DETERMINATION OF CHLOROETHENES IN ENVIRONMENTAL BIOLOGICAL SAMPLES USING GAS CHROMATOGRAPHY COUPLED WITH SOLID PHASE MICRO EXTRACTION

    EPA Science Inventory

    An analytical method has been developed to determine the chloroethene series, tetrachloroethene (PCE), trichloroethene (TCE),cisdichloroethene (cis-DCE) andtransdichloroethene (trans-DCE) in environmental biotreatment studies using gas chromatography coupled with a solid phase mi...

  2. Chemical Composition of Latent Fingerprints by Gas Chromatography-Mass Spectrometry

    ERIC Educational Resources Information Center

    Hartzell-Baguley, Brittany; Hipp, Rachael E.; Morgan, Neal R.; Morgan, Stephen L.

    2007-01-01

    An experiment in which gas chromatography-mass spectrometry (GC-MS) is used for latent fingerprint extraction and analysis on glass beads or glass slides is conducted. The results determine that the fingerprint residues are gender dependent.

  3. VACUUM DISTILLATION COUPLED WITH GAS CHROMATOGRAPHY/MASS SPECTROMETRY FOR THE ANALYSIS OF ENVIRONMENTAL SAMPLES

    EPA Science Inventory

    A procedure is presented that uses a vacuum distillation/gas chromatography/mass spectrometry system for analysis of problematic matrices of volatile organic compounds. The procedure compensates for matrix effects and provides both analytical results and confidence intervals from...

  4. Preparation of pure microbiological samples for pyrolysis gas-liquid chromatography studies

    NASA Technical Reports Server (NTRS)

    Oxborrow, G. S.; Fields, N. D.; Puleo, J. R.

    1976-01-01

    Bacterial samples were prepared for pyrolysis gas-liquid chromatography using cells grown on membrane filters. Pyrochromatograms were reproducible when cells harvested from the filters were pyrolyzed without being washed.

  5. Rapid discrimination of slimming capsules based on illegal additives by electronic nose and flash gas chromatography.

    PubMed

    Xia, Zhenzhen; Cai, Wensheng; Shao, Xueguang

    2015-02-01

    The discrimination of counterfeit and/or illegally manufactured medicines is an important task in the pharmaceutical industry for pharmaceutical safety. In this study, 22 slimming capsule samples with illegally added sibutramine and phenolphthalein were analyzed by electronic nose and flash gas chromatography. To reveal the difference among the different classes of samples, principal component analysis and linear discriminant analysis were employed to analyze the data acquired from electronic nose and flash gas chromatography, respectively. The samples without illegal additives can be discriminated from the ones with illegal additives by using electronic nose or flash gas chromatography data individually. To improve the performance of classification, a data fusion strategy was applied to integrate the data from electronic nose and flash gas chromatography data into a single model. The results show that the samples with phenolphthalein, sibutramine and both can be classified well by using fused data. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. VACUUM DISTILLATION COUPLED WITH GAS CHROMATOGRAPHY/MASS SPECTROMETRY FOR THE ANALYSIS OF ENVIRONMENTAL SAMPLES

    EPA Science Inventory

    A procedure is presented that uses a vacuum distillation/gas chromatography/mass spectrometry system for analysis of problematic matrices of volatile organic compounds. The procedure compensates for matrix effects and provides both analytical results and confidence intervals from...

  7. Preparation of pure microbiological samples for pyrolysis gas-liquid chromatography studies

    NASA Technical Reports Server (NTRS)

    Oxborrow, G. S.; Fields, N. D.; Puleo, J. R.

    1976-01-01

    Bacterial samples were prepared for pyrolysis gas-liquid chromatography using cells grown on membrane filters. Pyrochromatograms were reproducible when cells harvested from the filters were pyrolyzed without being washed.

  8. ENVIRONMENTAL ANALYSIS BY AB INITIO QUANTUM MECHANICAL COMPUTATION AND GAS CHROMATOGRAPHY/FOURIER TRANSFORM INFRARED SPECTROMETRY.

    EPA Science Inventory

    Computational chemistry, in conjunction with gas chromatography/mass spectrometry/Fourier transform infrared spectrometry (GC/MS/FT-IR), was used to tentatively identify seven tetrachlorobutadiene (TCBD) isomers detected in an environmental sample. Computation of the TCBD infrare...

  9. Evaluation of Gas Chromatography/Mini-IMS to Detect VOCs

    NASA Technical Reports Server (NTRS)

    Limero, Thomas; Reese, Eric; Peters, Randy; James, John T.; Billica, Roger (Technical Monitor)

    1999-01-01

    The Toxicology Laboratory at Johnson Space Center (JSC) has pioneered the use of gas chromatography-ion mobility spectrometry (GC/IMS) for measuring target volatile organic compounds (VOCs) aboard spacecraft. Graseby Dynamics, under contract to NASA/Wyle, has built several volatile organic analyzers (VOA) based on GC/IMS. Foremost among these have been the volatile organic analyzer-risk mitigation unit and the two flight VOA units for International Space Station (ISS). The development and evaluation of these instruments has been chronicled through presentations at the International Conference on Ion Mobility Spectrometry over the past three years. As the flight VOA from Graseby is prepared for operation on ISS at JSC, it is time to begin evaluations of technologies for the next generation VOA, Although the desired instrument characteristics for the next generation unit are the same as the current unit, the requirements are much more stringent. As NASA looks toward future missions beyond Earth environs, a premium will be placed upon small, light, reliable, autonomous hardware. It is with these visions in mind that the JSC Toxicology Laboratory began a search for the next generation VOA. One technology that is a candidate for the next generation VOA is GC/IMS. The recent miniaturization of IMS technology permits it to compete with other, inherently small, technologies such as chip-sized sensor arrays. This paper will discuss the lessons learned from the VOA experience and how that has shaped the design of a potential second generation VOA based upon GC/IMS technology. Data will be presented from preliminary evaluations of GC technology and the mini-IMS when exposed to VOCs likely to be detected aboard spacecraft. Results from the evaluation of an integrated GC/mini-IMS system will be shown if available.

  10. Investigation of modulation parameters in multiplexing gas chromatography.

    PubMed

    Trapp, Oliver

    2010-10-22

    Combination of information technology and separation sciences opens a new avenue to achieve high sample throughputs and therefore is of great interest to bypass bottlenecks in catalyst screening of parallelized reactors or using multitier well plates in reaction optimization. Multiplexing gas chromatography utilizes pseudo-random injection sequences derived from Hadamard matrices to perform rapid sample injections which gives a convoluted chromatogram containing the information of a single sample or of several samples with similar analyte composition. The conventional chromatogram is obtained by application of the Hadamard transform using the known injection sequence or in case of several samples an averaged transformed chromatogram is obtained which can be used in a Gauss-Jordan deconvolution procedure to obtain all single chromatograms of the individual samples. The performance of such a system depends on the modulation precision and on the parameters, e.g. the sequence length and modulation interval. Here we demonstrate the effects of the sequence length and modulation interval on the deconvoluted chromatogram, peak shapes and peak integration for sequences between 9-bit (511 elements) and 13-bit (8191 elements) and modulation intervals Δt between 5 s and 500 ms using a mixture of five components. It could be demonstrated that even for high-speed modulation at time intervals of 500 ms the chromatographic information is very well preserved and that the separation efficiency can be improved by very narrow sample injections. Furthermore this study shows that the relative peak areas in multiplexed chromatograms do not deviate from conventionally recorded chromatograms. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Urinary 19-norandrosterone purification by immunoaffinity chromatography: application to gas chromatography/combustion/isotope ratio mass spectrometric analysis.

    PubMed

    Desroches, M C; Mathurin, J C; Richard, Y; Delahaut, P; de Ceaurriz, J

    2002-01-01

    The detection of exogenous 19-norandrosterone (19-NA) in urines was investigated by using gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). 19-NA is, for the first time to our knowledge, isolated from urinary matrix by specific immunoaffinity chromatography (IAC) before analysis. The sample preparation consisted of a preliminary purification of urine by solid-phase extraction after hydrolysis by beta-glucuronidase. Unconjugated 19-NA was thus isolated by IAC and directly analysed by GC/C/IRMS. Optimisation of IAC purification was achieved and the reliability of the technique for anti-doping control is discussed.

  12. Purification of human milk gangliosides by silica gel chromatography and analysis of trifluoroacetate derivatives by gas chromatography.

    PubMed

    Laegreid, A; Kolstø Otnaess, A B; Bryn, K

    1986-04-25

    Two of the main gangliosides in human milk were purified by silica gel (230-400 mesh) column chromatography. The gangliosides were identified as GD3 and GM3 by methanolysis (2 M hydrochloric acid; 60 or 85 degrees C) and gas chromatography of trifluoroacetate derivatives on a fused-silica capillary column. The molar ratios of galactose, glucose and sialic acid were 1:1:2 and 1:1:1, respectively, and the sequence in both gangliosides comprised sialic acid--galactose--glucose--ceramide, as indicated by the time course of cleavage of individual components during methanolysis at 60 degrees C.

  13. Saturation region of helium ionization detector for gas-solid and gas-liquid chromatography

    SciTech Connect

    Andrawes, F.F.; Brazell, R.S.; Gibson, E.K.

    1980-05-01

    In the saturation region of the helium detector field intensity, the detector response is independent of the electrical field. In this region (at applied potential between 200 to 2000 volts per centimeter of electrode surface) the detector is operated at a low background current, and a low noise level, but it still exhibits a stable and sensitive response. The detector in this region can be operated with high purity grade helium without any further elaborate purification processes to yield a positive response to all compounds and gases tested. The operation of the detector in this mode has been adapted to both gas-solid and gas-liquid chromatography, with temperature programming. A sample can be introduced to the column via a gas sampling injection valve or via a syringe by direct injection into a modified injection port. The detector response is linear over a range of 10/sup 6/ units with a detection limit in the picogram range for organic compounds. 11 figures.

  14. Doping control analysis of anabolic steroids in equine urine by gas chromatography-tandem mass spectrometry.

    PubMed

    Wong, April S Y; Leung, Gary N W; Leung, David K K; Wan, Terence S M

    2017-09-01

    Anabolic steroids are banned substances in equine sports. Gas chromatography-mass spectrometry (GC-MS) has been the traditional technique for doping control analysis of anabolic steroids in biological samples. Although liquid chromatography-mass spectrometry (LC/MS) has become an important technique in doping control, the detection of saturated hydroxysteroids by LC-MS remains a problem due to their low ionization efficiency under electrospray. The recent development in fast-scanning gas-chromatography-triple-quadrupole mass spectrometry (GC-MS/MS) has provided a better alternative with a significant reduction in chemical noise by means of selective reaction monitoring. Herein, we present a sensitive and selective method for the screening of over 50 anabolic steroids in equine urine using gas chromatography-tandem mass spectrometry (GC-MS/MS). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. High resolution gas chromatography analysis of rice bran oil

    NASA Astrophysics Data System (ADS)

    Yu, Fengxiang; Lin, Qinlu; Chen, Xu; Wei, Xiaojun

    To assess the nutritional value and safety quality of rice bran oil (RBO) ,fatty acids of RBO from 15 species rice come from Hunan Province were analyzed by high resolution gas chromatography (HRGC). Crude RBOs were extracted by hexane 3-times using a solvent-to-rice bran ratio of 3:1 (w/w) at 40°C and composition of RBOs was analyzed by HRGC. The result showed that main fatty acids of 15 kinds of RBO include myristic acid (C14:0), palmitic acid (C16:0), palmitoleic acid (C16:1), stearic acid (C18:0), oleic acid (C18:1), linoleic acid (C18:2), linolenic acid (C18:3), arachidic acid (C20:0), arachidonic acid (C20:1). It is strange that arachidonic acid (C20:1) is not listed in Chinese standard of RBO (GB11192-2003), and it exists in our samples of RBO. The average value of linolenic acid in RBOs is 1.6304% (range from 1.2425% to 2.131%), and it showed higher level comparing with Chinese standard that linolenic acid is less than 1.0%. The average value of USFA and SFA are 76.81% (range 75.96% to 82.06% ) and 20.15% (range 13.72% to 23.06%) respectively, and USFA content is close to olive oil (83.75%), peanut oil (81.75%) and soybean oil (85.86%). USFA in Jingyou 13 RBO is the highest content. The ratio of USFA to SFA content is 4:1 (range from 3.32 to 5.98:1). The ratio of SFA: MUFA: PUFA of 15 RBOs is 1: 2.2: 1.8, and ω6/ω3 ratio is 21.69 (range from16.54 to 27.28) and it is close to the 26:1 which is reported to be helpful to increase SOD activity. The oleic acid /linoleic acid ratio of 15 RBOs is 1.23:1 (rang from 1.04:1 to 1.42:1). Our data analyzed composition of RBOs from 15 species rice of China and will provide new evidence to revise RBO standard. It also helps us to assess nutritional value of RBOs and identify different RBOs from various species rice and places of origin.

  16. Analysis of radioactive mixed hazardous waste using derivatization gas chromatography/mass spectrometry, liquid chromatography, and liquid chromatography/mass spectrometry

    SciTech Connect

    Campbell, J.A.; Lerner, B.D.; Bean, R.M.; Grant, K.E.; Lucke, R.B.; Mong, G.M.; Clauss, S.A.

    1994-08-01

    Six samples of core segments from Tank 101-SY were analyzed for chelators, chelator fragments, and several carboxylic acids by derivatization gas chromatography/mass spectrometry. The major components detected were ethylenediaminetetraacetic acid, nitroso-iminodiacetic acid, nitrilotriacetic acid, citric acid, succinic acid, and ethylenediaminetriacetic acid. The chelator of highest concentration was ethylenediaminetetraacetic acid in all six samples analyzed. Liquid chromatography was used to quantitate low molecular weight acids including oxalic, formic, glycolic, and acetic acids, which are present in the waste as acid salts. From 23 to 61% of the total organic carbon in the samples analyzed was accounted for by these acids.

  17. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Miller, C. J.; Elias, G.; Schmitt, N. C.; Rae, C.

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify trace levels of the military explosives, RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol and filtered using no additional sample cleanup of the sample extract prior to analysis. The filtered methanol extracts were injected directly into several different column types and analyzed by high performance liquid chromatography using ultraviolet detection and/or gas chromatography using electron capture detection. This paper describes general screening methods that were used to determine the presence of explosives (RDX, TNT, and PETN) in unknown samples of denim, colored flannel, vinyl and canvas in addition to techniques that have been optimized for quantification of each explosive from the substrate extracts.

  18. Investigation of Pinus mugo essential oil oxygenated fraction by combined use of gas chromatography and dry column chromatography.

    PubMed

    A, M B; Coran, S A; Giannellini, V; Vincieri, F F; Moneti, G

    1981-09-01

    The oxygenated compounds of Pinus mugo Turra essential oil were investigated by a combination of GC and dry column chromatography (DCC) coordinated by GC data processing. The collected data resulted in a bar graph ("normalized" gas chromatogram) giving the RRT's and relative amounts of 68 components; 38 of them were identified by MS and IR. The described procedure may be used for essential oil analysis in general.

  19. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.

    1989-01-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan

  20. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres.

    PubMed

    Valentin, J R

    1989-03-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan

  1. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.

    1989-01-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan

  2. Study on volatile components in salami by reverse carrier gas headspace gas chromatography-mass spectrometry.

    PubMed

    Procida, G; Conte, L S; Fiorasi, S; Comi, G; Favretto, L G

    1999-01-08

    Salami are a typical seasoned sausage of Italy; a number of types are produced, according to local traditional recipes. As industrial production has taken place, a number of problems rise in obtaining products similar to the traditional ones. The use of selected microbial starters is permitted by Italian law for some years and at present, microbiological research is engaged in selecting starters similar to the ones isolated from traditional products, with the aim of obtaining organoleptic characteristics close to the ones of traditional recipes. A study was carried out concerning the characterisation of volatile components of salami by headspace capillary gas chromatography-mass spectrometry. As during the sampling step, analytes could reach the analytical column, the carrier gas rate was back flushed in the latter, while a pre column was used as cold trap. Then GC-MS analysis follows. By these techniques, we were able to highlight typical profiles of different salami, as well as monitoring the ripening of a traditional and a starter added salami. Main peaks are of fermentative origin, while also peaks from spices were detected. Ethyl propionate was used as internal standard to be able to normalise the peaks amounts.

  3. Impact of comprehensive two-dimensional gas chromatography with mass spectrometry on food analysis.

    PubMed

    Tranchida, Peter Q; Purcaro, Giorgia; Maimone, Mariarosa; Mondello, Luigi

    2016-01-01

    Comprehensive two-dimensional gas chromatography with mass spectrometry has been on the separation-science scene for about 15 years. This three-dimensional method has made a great positive impact on various fields of research, and among these that related to food analysis is certainly at the forefront. The present critical review is based on the use of comprehensive two-dimensional gas chromatography with mass spectrometry in the untargeted (general qualitative profiling and fingerprinting) and targeted analysis of food volatiles; attention is focused not only on its potential in such applications, but also on how recent advances in comprehensive two-dimensional gas chromatography with mass spectrometry will potentially be important for food analysis. Additionally, emphasis is devoted to the many instances in which straightforward gas chromatography with mass spectrometry is a sufficiently-powerful analytical tool. Finally, possible future scenarios in the comprehensive two-dimensional gas chromatography with mass spectrometry food analysis field are discussed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Recent advances in liquid and gas chromatography methodology for extending coverage of the metabolome.

    PubMed

    Haggarty, Jennifer; Burgess, Karl Ev

    2017-02-01

    The metabolome is the complete complement of metabolites (small organic biomolecules). In order to comprehensively understand the effect of stimuli on a biological system, it is important to detect as many of the metabolites within that system as possible. This review briefly describes some new advances in liquid and gas chromatography to improve coverage of the metabolome, including the serial combination of two columns in tandem, column switching and different variations of two-dimensional chromatography. Supercritical fluid chromatography could provide complimentary data to liquid and gas chromatography. Although there have been many recent advancements in the field of metabolomics, it is evident that a combination, rather than a single method, is required to approach full coverage of the metabolome. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Optimisation of stir bar sorptive extraction and in-tube derivatisation-thermal desorption-gas chromatography-mass spectrometry for the determination of several endocrine disruptor compounds in environmental water samples.

    PubMed

    Iparraguirre, Arantza; Prieto, Ailette; Navarro, Patricia; Olivares, Maitane; Fernández, Luis-Ángel; Zuloaga, Olatz

    2011-07-01

    The analysis of organic pollutants in environmental water samples requires a pre-concentration step. Pre-concentration techniques such as stir bar sorptive extraction (SBSE) have gained popularity since they minimise the use of toxic organic solvents and can be considered as green analytical techniques. Similar to other pre-concentration techniques, one of the problems when SBSE is used is the matrix effect, which often occurs during the analysis of environmental water samples such as estuarine or wastewater samples. The present work studied the matrix effect during SBSE coupled to in-tube derivatisation-thermal desorption (TD)-gas chromatography-mass spectrometry for the determination of several endocrine disruptor compounds, such as alkylphenols, bisphenol A, estrogens and sterols, in environmental water samples, after optimisation of the major variables affecting the determination. Variables such as the addition of methanol or an inert salt to the donor phase, the extraction temperature, the volume of the donor phase, the stirring rate and the extraction time were studied during the SBSE optimisation. In the case of the in-tube derivatisation and TD step, the volume of the derivatisation reagent (N,O-bis(trimethylsilyl)triufloroacetamide with 1% of trimethylchlorosilane (BSTFA + 1% TMCS)) and the cryo-focusing temperature were fixed (2 μL and -50 °C, respectively) according to a consensus between maximum signal and optimal operation conditions. Good apparent recovery values (78-124%) were obtained for most of the analytes in Milli-Q water, except for 4-tert-octylphenol (4-tOP), which showed apparent recovery values exceeding 100%. Precision (n = 4) was in the 2-27%, and method detection limits were in the low nanogrammes per litre level for most of the analytes studied. The matrix effect was studied using two different approaches. On the one hand, Milli-Q water samples were spiked with humic acids, and apparent recovery values were studied with and

  6. Adsorption and displacement effects in the gas-chromatography of metal beta-diketonates.

    PubMed

    Uden, P C; Jenkins, C R

    1969-07-01

    A detailed study of the gas chromatography of the aluminium(III), chromium(III) and iron(III) beta-diketonates has shown that their elution and separation characteristics arise from a number of adsorptive effects. Conditions of optimal peak shape for individual compounds are established by varying Chromatographie parameters, and the adsorption of one metal chelate on a column and its subsequent displacement by another chelate are investigated. The chromatography of iron(III) beta-diketonates is seen to be further complicated by gradual elution of a portion of the chelate before the rest of the sample.

  7. [Simultaneous determination of three antioxidants BHA, BHT and TBHQ in food by liquid chromatography and gas chromatography].

    PubMed

    Yang, Jie; Fang, Congrong; Yang, Dajin

    2013-01-01

    To develop a method for determining 3 kinds of antioxidants in food in same time with HPLC and GC. Firstly, extracted fat with petroleum ether, then extracted antioxidants with 13 ml methnol, centrifuged, repeated the above procedure twice, combined the extracts, next evaporated to 5 ml, constanted volume to 10 ml, then kepted in freezer (- 1h), lastly, the supernatant injected into high performance liquid chromatography (HPLC) and Gas chromatography (GC) which had been optimized condition. The limits of quantitation for BHA,BHT and TBHQ were 0.002, 0.010 and 0.002g/kg respectively in HPLC, The limits of quantitation for BHA, BHT and TBHQ were 0.003, 0.002 and 0.005 g/kg respectively in GC, The mean recoveries at the two spiked levels were 82.8% - 109.0%. There were no significant difference between HPLC and GC. The method can be used to determine the antioxidants in food accurately and sensitively, the comparative results are constant between liquid and gas chromatography.

  8. Application of gas chromatography to analysis of spirit-based alcoholic beverages.

    PubMed

    Wiśniewska, Paulina; Śliwińska, Magdalena; Dymerski, Tomasz; Wardencki, Waldemar; Namieśnik, Jacek

    2015-01-01

    Spirit-based beverages are alcoholic drinks; their production processes are dependent on the type and origin of raw materials. The composition of this complex matrix is difficult to analyze, and scientists commonly choose gas chromatography techniques for this reason. With a wide selection of extraction methods and detectors it is possible to provide qualitative and quantitative analysis for many chemical compounds with various functional groups. This article describes different types of gas chromatography techniques and their most commonly used associated extraction techniques (e.g., LLE, SPME, SPE, SFE, and SBME) and detectors (MS, TOFMS, FID, ECD, NPD, AED, O or EPD). Additionally, brief characteristics of internationally popular spirit-based beverages and application of gas chromatography to the analysis of selected alcoholic drinks are presented.

  9. Determination of parts-per-billion concentrations of dioxane in water and soil by purge and trap gas chromatography/mass spectrometry or charcoal tube enrichment gas chromatography

    SciTech Connect

    Epstein, P.S.; Mauer, T.; Wagner, M.; Chase, S.; Giles, B.

    1987-08-01

    Two methods for the determination of 1,4-dioxane in water have been studied. The first method is a heated purge and trap gas chromatography/mass spectrometry system following salting out with sodium sulfate. The second method is an adsorption on coconut-shell charcoal and solvent desorption with carbon disulfide/methanol followed by analysis of the desorbate by gas chromatography with flame ionization detection. The first method is also successful for the determination of 1,4-dioxane in solids and sediments. The second method is shown to be successful for 2-butanone, 4-methyl-2-pentanone, and butoxyethanol in water. The two methods are compared by analyzing 15 samples by both methods and achieving similar results.

  10. Qualitative and quantitative analysis of vetiver essential oils by comprehensive two-dimensional gas chromatography and comprehensive two-dimensional gas chromatography/mass spectrometry.

    PubMed

    Filippi, Jean-Jacques; Belhassen, Emilie; Baldovini, Nicolas; Brevard, Hugues; Meierhenrich, Uwe J

    2013-05-03

    Vetiver essential oils (VEO) are important raw ingredients used in perfume industry, entering the formula of numerous modern fragrances. Vetiver oils are considered to be among the most complex essential oils, resulting most of the time in highly coeluted chromatograms whatever the analytical technique. In this context, conventional gas chromatography has failed to provide a routine tool for the accurate qualitative and quantitative analysis of their constituents. Applying comprehensive two-dimensional gas chromatography techniques (GC×GC-FID/MS) afforded the mean to separate efficiently vetiver oil constituents in order to identify them in a more reliable way. Moreover, this is the first time that a complete true quantitation of each constituent is carried out on such complex oils by means of internal calibration. Finally, we have studied the influence of the injection mode on the determined chemical composition, and showed that several alcohols underwent dehydration under defined chromatographic conditions (splitless mode) usually recommended for quantitation purposes.

  11. Characterization of aroma-active compounds in three Chinese Moutai liquors by gas chromatography-olfactometry, gas chromatography-mass spectrometry and sensory evaluation.

    PubMed

    Niu, Yunwei; Chen, Xiaomei; Xiao, Zuobing; Ma, Ning; Zhu, Jiancai

    2017-04-01

    The aroma-active compounds in three Chinese Moutai liquors, aged 1 year, 15 years and 30 years were investigated in this study. The aroma compounds were analysed by gas chromatography-olfactometry (GC-O) coupled with gas chromatography-mass spectrometry (GC-MS). A total of 79 aroma compounds were identified. Aroma extract dilution analysis (AEDA) was further employed to identify the aroma-active compounds. A total of 35 aroma-active compounds with flavour dilution (FD) values ≧ 64 simultaneously in three Chinese Moutai liquors were quantitated. Among them, ethyl acetate, ethyl lactate and acetic acid appeared with the highest concentrations. They were all >1000 mg/L. Then, the relationships between the aroma-active compounds and seven sensory attributes were studied.

  12. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    SciTech Connect

    C.J. Miller; G. Elias; N.C. Schmitt; C. Rae

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that were used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.

  13. Analyzing salvia divinorum and its active ingredient salvinorin a utilizing thin layer chromatography and gas chromatography/mass spectrometry.

    PubMed

    Jermain, John D; Evans, Hiram K

    2009-05-01

    In recent years, Salvia divinorum has become a major focus by state legislatures throughout the United States looking to prohibit the sale of the psychoactive plant. After researching testing procedures presented in the literature and those employed by crime laboratories throughout the country, it was decided that thin layer chromatography (TLC) and gas chromatography/mass spectrometry (GC/MS) were the methods to use to analyze plant material for salvinorin A. With TLC, salvinorin A was detected from extracted plant material and was easily distinguishable from 13 other Salvia species as well as Cannabis sativa L. (marijuana). When using GC/MS, salvinorin A was best extracted from plant material with chloroform at ambient temperature when using a nonpolar solvent and acetone at ambient temperature when using a polar solvent. By utilizing these techniques, criminalists are now able to confirm the presence of salvinorin A in a submitted plant material suspected to be Salvia divinorum.

  14. Pyrolysis-gas chromatography-mass spectrometry of a series of bile acid sequestrants.

    PubMed

    Haskins, N J; Eckers, C; Mitchell, R

    1992-09-01

    Pyrolysis of a series of polymers based on polystyrene and used as bile acid sequestrants produced characteristic mixtures of compounds which were analysed by gas chromatography-mass spectrometry. The nature of the substituent groups was clearly apparent while the polymer backbone gave rise to representative styrenes. The reproducibility of the results was examined by experimenting with the temperature of pyrolysis. It was found that at low temperatures very little fragmentation of the polystyrene backbone occurred but the substituents were still released in high yield. The orientation of the various substituted styrenes generated by pyrolysis was confirmed by the use of gas chromatography with infrared and mass spectrometric detection.

  15. A research on integrated-circuit sensors for gas chromatography

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Fabrication of a miniature gas chromatograph column using integrated circuit technology was studied and found to be feasible. A bonding problem of forming a strong, gas tight seal between two wafers of silicon has prevented the completion of the column design. Continuing research using tin or a chromium-gold bond promises to overcome the problems of using the proposed gold-eutectic bond. Specifications for the miniature gas chromatograph column are: a spiral capillary column of semi-circular cross section, 30 micron radius, and a total length of 6.9 meters etched into a silicon structure 50 mm in diameter and 0.625 mm thick.

  16. XCIII. A Low-Cost Temperature Programmer for Gas Chromatography

    ERIC Educational Resources Information Center

    Gallaher, T. N.; And Others

    1977-01-01

    Describes the construction and operation of a temperature programmer; it can be built for less than $100 and can be used with any gas chromatograph that uses a variable resistor to control oven temperature. (MLH)

  17. Measuring Carbon Monoxide in Auto Exhaust by Gas Chromatography.

    ERIC Educational Resources Information Center

    Jaffe, Dan; Herndon, Scott

    1995-01-01

    Presents a simple and reliable technique using commonly available equipment for monitoring carbon monoxide in automobile exhaust. The experiment utilizes a gas chromatograph and a thermal conductivity detector (TCD). (DDR)

  18. Trace hydrazines in aqueous solutions accurately determined by gas chromatography

    NASA Technical Reports Server (NTRS)

    Welz, E. A., Jr.

    1967-01-01

    Trace amounts of hydrazines in aqueous solutions can be determined by using polythyleneimine /PEI/ in conjunction with the gas chromatographic column. The PEI specifically retains water without altering the separability or elution order of the hydrazine and associated constituents.

  19. Measuring Carbon Monoxide in Auto Exhaust by Gas Chromatography.

    ERIC Educational Resources Information Center

    Jaffe, Dan; Herndon, Scott

    1995-01-01

    Presents a simple and reliable technique using commonly available equipment for monitoring carbon monoxide in automobile exhaust. The experiment utilizes a gas chromatograph and a thermal conductivity detector (TCD). (DDR)

  20. Advancement and application of gas chromatography isotope ratio mass spectrometry techniques for atmospheric trace gas analysis

    NASA Astrophysics Data System (ADS)

    Giebel, Brian M.

    2011-12-01

    The use of gas chromatography isotope ratio mass spectrometry (GC-IRMS) for compound specific stable isotope analysis is an underutilized technique because of the complexity of the instrumentation and high analytical costs. However stable isotopic data, when coupled with concentration measurements, can provide additional information on a compounds production, transformation, loss, and cycling within the biosphere and atmosphere. A GC-IRMS system was developed to accurately and precisely measure delta13C values for numerous oxygenated volatile organic compounds having natural and anthropogenic sources. The OVOCs include methanol, ethanol, acetone, methyl ethyl ketone, 2-pentanone, and 3-pentanone. Guided by the requirements for analysis of trace components in air, the GC-IRMS system was developed with the goals of increasing sensitivity, reducing dead-volume and peak band broadening, optimizing combustion and water removal, and decreasing the split ratio to the IRMS. The technique relied on a two-stage preconcentration system, a low-volume capillary reactor and water trap, and a balanced reference gas delivery system. Measurements were performed on samples collected from two distinct sources (i.e. biogenic and vehicle emissions) and ambient air collected from downtown Miami and Everglades National Park. However, the instrumentation and the method have the capability to analyze a variety of source and ambient samples. The measured isotopic signatures that were obtained from source and ambient samples provide a new isotopic constraint for atmospheric chemists and can serve as a new way to evaluate their models and budgets for many OVOCs. In almost all cases, OVOCs emitted from fuel combustion were enriched in 13C when compared to the natural emissions of plants. This was particularly true for ethanol gas emitted in vehicle exhaust, which was observed to have a uniquely enriched isotopic signature that was attributed to ethanol's corn origin and use as an alternative

  1. Determination of Dihydroqinghaosu in Blood by Pyrolysis Gas Chromatography/Mass Spectrometry

    DTIC Science & Technology

    1988-01-15

    capillary the therapeutic range, our laboratory sought to develop new column gas chromatography/mass spectrometry ( GCMS ) specific and sensitive methodologies...paper, the results on the development and validation of packed for pharmacoklneUc an metabolism studies In animals. and capillary column gas...respectively. Petroleum ether washave been treated with QHS or its derivatives in China with purchased from Mallinckrodt, Inc. (Paris, KY), and ethyl acetate

  2. High-voltage spark atomic emission detector for gas chromatography

    NASA Technical Reports Server (NTRS)

    Calkin, C. L.; Koeplin, S. M.; Crouch, S. R.

    1982-01-01

    A dc-powered, double-gap, miniature nanosecond spark source for emission spectrochemical analysis of gas chromatographic effluents is described. The spark is formed between two thoriated tungsten electrodes by the discharge of a coaxial capacitor. The spark detector is coupled to the gas chromatograph by a heated transfer line. The gas chromatographic effluent is introduced into the heated spark chamber where atomization and excitation of the effluent occurs upon breakdown of the analytical gap. A microcomputer-controlled data acquisition system allows the implementation of time-resolution techniques to distinguish between the analyte emission and the background continuum produced by the spark discharge. Multiple sparks are computer averaged to improve the signal-to-noise ratio. The application of the spark detector for element-selective detection of metals and nonmetals is reported.

  3. Recent progress of chiral stationary phases for separation of enantiomers in gas chromatography.

    PubMed

    Xie, Sheng-Ming; Yuan, Li-Ming

    2017-01-01

    Chromatography techniques based on chiral stationary phases are widely used for the separation of enantiomers. In particular, gas chromatography has developed rapidly in recent years due to its merits such as fast analysis speed, lower consumption of stationary phases and analytes, higher column efficiency, making it a better choice for chiral separation in diverse industries. This article summarizes recent progress of novel chiral stationary phases based on cyclofructan derivatives and chiral porous materials including chiral metal-organic frameworks, chiral porous organic frameworks, chiral inorganic mesoporous materials, and chiral porous organic cages in gas chromatography, covering original research papers published since 2010. The chiral recognition properties and mechanisms of separation toward enantiomers are also introduced.

  4. Process gas chromatography study of a Selexol acid gas removal system. Final report Mar-Sep 82

    SciTech Connect

    Williams, W.A.

    1984-01-01

    The report gives results of continuous compositional monitoring by process gas chromatography (GC) for three gas streams associated with the Selexol acid gas removal system at the Bi-Gas pilot plant in Homer City, PA. Data were obtained from the inlet and outlet streams of the Selexol system during tests in April and May 1982. Product gas composition data were logged for 55 hours of plant operation. The Bi-Gas pilot plant, utilizing a two-stage, entrained-bed, high-pressure slagging gasifier, produces a product gas that is low in tars and heavy oils. This gas stream required very little cleanup prior to instrumental analysis. However, some problems were encountered in the analysis of the Selexol acid gas stream due to the presence of high levels of naphthalene. The process gas chromatographs performed well and remained very stable during the tests. Material balances based on GC analyses and process flow rate data show a high degree of material accountability. The H/sub 2/S removal efficiency of the Selexol absorber was about 99% during the tests.

  5. Quantitation of monomers in poly(glyerol-co-diacid) gels using gas chromatography

    USDA-ARS?s Scientific Manuscript database

    The validation of a gas chromatography (GC) method developed to quantify amounts of starting material from the synthesis of hyperbranched polymers made from glycerol and either succinic acid, glutaric acid, or azelaic acid is described. The GC response to concentration was linear for all starting r...

  6. Analysis of Microorganisms by Oxidative and Non-Oxidative Pyrolysis Gas Chromatography Ion Trap Mass Spectrometry.

    DTIC Science & Technology

    1992-04-01

    Bacillus subtilis, Bacillus pumilus , Bacillus lichenformis, and Bacillus amyloliquefaciens by Pyrolysis-gas Liquid Chromatography, Deoxyribonucleic...FIGURES Number Page 1. Curie point pyrolysis GC-ITD data for Bacillus subtilis ................... 16 2. Total Ion Chromatograms for Bacillus subtilis...under oxidative and non-oxidative pyrolysis conditions ................................... 17 3. Total Lipid Mass Spectra for Bacillus subtilis under

  7. Qualitative Analysis by Gas Chromatography: GC versus the Nose in Formulating Artificial Fruit Flavors.

    ERIC Educational Resources Information Center

    Rasmussen, P. W.

    1984-01-01

    Describes an undergraduate laboratory experiment used to illustrate the use of gas chromatography retention indices for the identification of unknown compounds, specifically for the identification of unknown compounds and for the identification of the volatile compounds responsible for the odor of the banana. Procedures, reference data, and sample…

  8. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    ERIC Educational Resources Information Center

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  9. The determination of cyclohexylamine in aqueous solutions of sodium cyclamate by electron-capture gas chromatography.

    NASA Technical Reports Server (NTRS)

    Solomon, M. D.; Pereira, W. E.; Duffield, A. M.

    1971-01-01

    A sensitive primary amine assay, capable of detecting 10 to the minus 11th g and utilizing the determination of the amine N-2,4-dinitrophenyl derivative by electron-capture gas chromatography is described. The method is exemplified by the determination of cyclohexylamine in sodium cyclamate.

  10. An Application of Trimethylsilyl Derivatives with Temperature Programmed Gas Chromatography to the Senior Analytical Laboratory.

    ERIC Educational Resources Information Center

    Kelter, Paul B.; Carr, James D.

    1983-01-01

    Describes an experiment designed to teach temperature programed gas chromatography (TPGC) techniques and importance of derivatizing many classes of substrated to be separated. Includes equipment needed, procedures for making trimethylsilyl derivatives, applications, sample calculations, and typical results. Procedure required one, three-hour…

  11. The Separation and Identification of Straight Chain Hydrocarbons: An Experiment Using Gas-Liquid Chromatography.

    ERIC Educational Resources Information Center

    Benson, G. A.

    1982-01-01

    An experiment using gas-liquid chromatography is discussed, introducing the student to concept of dead volume and its measurement, idea and use of an internal reference compound, and to linear relationship existing between measurements of a separation on two different stationary phases. (Author/SK)

  12. A Gas Chromatography Experiment for Proving the Application of Quantum Symmetry Restrictions in Homonuclear Diatomic Molecules.

    ERIC Educational Resources Information Center

    Dosiere, M.

    1985-01-01

    Background information, procedures used, and typical results obtained are provided for an experiment in which gas chromatography is used to prove the application of quantum symmetry restrictions in homonuclear diatomic molecules. Comparisons between experimental results and theoretical computed values show good agreement, within one to two…

  13. Planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as stationary phase

    NASA Astrophysics Data System (ADS)

    Platonov, I. A.; Platonov, V. I.; Pavelyev, V. S.

    2016-04-01

    The high selectivity of the adsorption layer for low-boiling alkanes is shown, the separation factor (α) couple iso-butane / butane is 1.9 at a column temperature of 50 °C.The paper presents sorption and selective properties of planar gas chromatography column on aluminum plate with multi-walled carbon nanotubes as the stationary phase.

  14. A multivariate statistical analysis approach to analyze gas chromatography-olfactometry data of tangerine hybrids

    USDA-ARS?s Scientific Manuscript database

    Gas chromatography (GC) hyphenated with olfactometry (O) when a human subject smells the effluent of the GC is a useful technique to identify aroma activity of volatile compounds in a food. Many techniques have been developed, based on olfactory thresholds (CHARM analysis, AEDA), or based on psychop...

  15. Identification of Synthetic Polymers and Copolymers by Analytical Pyrolysis-Gas Chromatography/Mass Spectrometry

    ERIC Educational Resources Information Center

    Kusch, Peter

    2014-01-01

    An experiment for the identification of synthetic polymers and copolymers by analytical pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and performed in the polymer analysis courses for third-year undergraduate students of chemistry with material sciences, and for first-year postgraduate students of polymer sciences. In…

  16. DEVELOPMENTS IN DIRECT THERMAL EXTRACTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY OF FINE AEROSOLS

    EPA Science Inventory

    This examines thermal extraction gas chromatography-mass spectrometry (TE/GC/MS) applied to aerosols collected on filters. Several different TE/GC/MS systems as a group have speciated hundreds of individual organic constituents in ambient fine aerosols. Molecular marker source ap...

  17. Tracking the Weathering of an Oil Spill with Comprehensive Two-Dimensional Gas Chromatography

    DTIC Science & Technology

    2006-01-01

    15275920500506758 Tracking the Weathering of an Oil Spill with Comprehensive Two-Dimensional Gas Chromatography Robert K. Nelson,1 Brian M. Kile ,1 Desiree L. Plata,1...Robert T. Alexander Trust. Brian M. Kile received support from the National Science Foundation’s Research Experience for Undergraduates program while a

  18. Identification of Synthetic Polymers and Copolymers by Analytical Pyrolysis-Gas Chromatography/Mass Spectrometry

    ERIC Educational Resources Information Center

    Kusch, Peter

    2014-01-01

    An experiment for the identification of synthetic polymers and copolymers by analytical pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and performed in the polymer analysis courses for third-year undergraduate students of chemistry with material sciences, and for first-year postgraduate students of polymer sciences. In…

  19. Review of recent developments and applications in low-pressure (vacuum outlet) gas chromatography

    USDA-ARS?s Scientific Manuscript database

    The concept of low pressure (LP) vacuum outlet gas chromatography (GC) was introduced more than 50 years ago, but it was not until the 2000s that its theoretical applicability to fast analysis of GC-amenable chemicals was realized. In practice, LPGC is implemented by placing the outlet of a short, ...

  20. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    ERIC Educational Resources Information Center

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  1. The properties of the wood-polystyrene interphase determined by inverse gas chromatography

    Treesearch

    John Simonsen; Zhenqiu Hong; Timothy G. Rials

    1997-01-01

    The properties of the interphase in wood-polymer composites are important determinants of the properties of the final composite. This study used inverse gas chromatography (IGC) to measure interphasal properties of composites of polystyrene and two types of wood fiber fillers and an inoranic substrate (CW) with varying amounts of surface coverage of polystyrene. Glass...

  2. Qualitative Analysis by Gas Chromatography: GC versus the Nose in Formulating Artificial Fruit Flavors.

    ERIC Educational Resources Information Center

    Rasmussen, P. W.

    1984-01-01

    Describes an undergraduate laboratory experiment used to illustrate the use of gas chromatography retention indices for the identification of unknown compounds, specifically for the identification of unknown compounds and for the identification of the volatile compounds responsible for the odor of the banana. Procedures, reference data, and sample…

  3. A Gas Chromatography Experiment for Proving the Application of Quantum Symmetry Restrictions in Homonuclear Diatomic Molecules.

    ERIC Educational Resources Information Center

    Dosiere, M.

    1985-01-01

    Background information, procedures used, and typical results obtained are provided for an experiment in which gas chromatography is used to prove the application of quantum symmetry restrictions in homonuclear diatomic molecules. Comparisons between experimental results and theoretical computed values show good agreement, within one to two…

  4. An Application of Trimethylsilyl Derivatives with Temperature Programmed Gas Chromatography to the Senior Analytical Laboratory.

    ERIC Educational Resources Information Center

    Kelter, Paul B.; Carr, James D.

    1983-01-01

    Describes an experiment designed to teach temperature programed gas chromatography (TPGC) techniques and importance of derivatizing many classes of substrated to be separated. Includes equipment needed, procedures for making trimethylsilyl derivatives, applications, sample calculations, and typical results. Procedure required one, three-hour…

  5. Investigating interphase development is wood polymer composites by inverse gas chromatography

    Treesearch

    Timothy G. Rials; John Simonsen

    2000-01-01

    The influence of secondary interactions on the development of interfacial structure in composites of wood and amorphous thermoplastic polymers is not well understood. This study used inverse gas chromatography to investigate the effect of different polymers on the surfirce energy of partially or fully coated white pine wood meal. In this way, the development of the...

  6. The Separation and Identification of Straight Chain Hydrocarbons: An Experiment Using Gas-Liquid Chromatography.

    ERIC Educational Resources Information Center

    Benson, G. A.

    1982-01-01

    An experiment using gas-liquid chromatography is discussed, introducing the student to concept of dead volume and its measurement, idea and use of an internal reference compound, and to linear relationship existing between measurements of a separation on two different stationary phases. (Author/SK)

  7. Gas chromatography-mass spectrometry (GC-MS) analysis of extractives of naturally durable wood

    Treesearch

    G.T. Kirker; A.B. Blodgett; S.T. Lebow; C.A. Clausen

    2011-01-01

    A preliminary study to evaluate naturally durable wood species in an above ground field trial using Gas Chromatography-Mass Spectrometry (GC-MS) detected differences in fatty acid extractives between species and within the same species over time. Fatty acids were extracted with chloroform: methanol mixture then methylated with sodium methoxide and fractionated using...

  8. Atmospheric pressure helium afterglow discharge detector for gas chromatography

    DOEpatents

    Rice, Gary; D'Silva, Arthur P.; Fassel, Velmer A.

    1986-05-06

    An apparatus for providing a simple, low-frequency electrodeless discharge system for atmospheric pressure afterglow generation. A single quartz tube through which a gas mixture is passed is extended beyond a concentric electrode positioned thereabout. A grounding rod is placed directly above the tube outlet to permit optical viewing of the discharge between the electrodes.

  9. Atmospheric pressure helium afterglow discharge detector for gas chromatography

    DOEpatents

    Rice, G.; D'Silva, A.P.; Fassel, V.A.

    1985-04-05

    An apparatus for providing a simple, low-frequency, electrodeless discharge system for atmospheric pressure afterglow generation. A single quartz tube through which a gas mixture is passed is extended beyond a concentric electrode positioned thereabout. A grounding rod is placed directly above the tube outlet to permit optical viewing of the discharge between the electrodes.

  10. Determination of methane in ambient air by multiplex gas chromatography

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.; Carle, G. C.; Phillips, J. B.

    1985-01-01

    A multiplex gas chromatographic technique for the determination of methane in ambient air over extended periods is reported. A modest gas chromatograph which uses air as the carrier gas was modified by adding a silver oxide sample modulator for multiplex operation. The modulator selectively catalyzes the decomposition of methane in air. The resulting analytical system requires no consumables beyond power. A profile of the methane concentration in this laboratory was obtained for an 8-day period. During this period, methane concentration varied with an approximately daily period from a low of 1.53 + or - 0.60 ppm to a high of 4.63 + or - 0.59 ppm over the entire 8 days. Some of the measured concentrations are higher than those reported elsewhere indicating the presence of some local source or sources for methane. This work has demonstrated the utility of a relatively simple multiplex gas chromatograph for the analysis of environmental samples. The technique should be applicable to other trace components in air through use of other selective modulators.

  11. Determination of pyrrolnitrin and derivatives by gas-liquid chromatography.

    PubMed

    Hamill, R L; Sullivan, H R; Gorman, M

    1969-09-01

    A gas-liquid chromatographic technique was applied to the separation of pyrrolnitrin and its derivatives. The simultaneous use of a flame detector and an electron capture detector made possible the distinction between the nitro derivatives of pyrrolnitrin and the other metabolites. The metabolites could be readily quantitated with the electron capture detector, offering a much more sensitive assay than the flame detector.

  12. Position sensitive radioactivity detection for gas and liquid chromatography

    DOEpatents

    Cochran, Joseph L.; McCarthy, John F.; Palumbo, Anthony V.; Phelps, Tommy J.

    2001-01-01

    A method and apparatus are provided for the position sensitive detection of radioactivity in a fluid stream, particularly in the effluent fluid stream from a gas or liquid chromatographic instrument. The invention represents a significant advance in efficiency and cost reduction compared with current efforts.

  13. Determination of methane in ambient air by multiplex gas chromatography

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.; Carle, G. C.; Phillips, J. B.

    1985-01-01

    A multiplex gas chromatographic technique for the determination of methane in ambient air over extended periods is reported. A modest gas chromatograph which uses air as the carrier gas was modified by adding a silver oxide sample modulator for multiplex operation. The modulator selectively catalyzes the decomposition of methane in air. The resulting analytical system requires no consumables beyond power. A profile of the methane concentration in this laboratory was obtained for an 8-day period. During this period, methane concentration varied with an approximately daily period from a low of 1.53 + or - 0.60 ppm to a high of 4.63 + or - 0.59 ppm over the entire 8 days. Some of the measured concentrations are higher than those reported elsewhere indicating the presence of some local source or sources for methane. This work has demonstrated the utility of a relatively simple multiplex gas chromatograph for the analysis of environmental samples. The technique should be applicable to other trace components in air through use of other selective modulators.

  14. Determination of microstickies in recycled whitewater by headspace gas chromatography

    Treesearch

    X.-S. Chai; J.C. Samp; Q.F. Yang; H.N. Song; J.Y. Zhu

    2007-01-01

    This study proposed a novel headspace gas chromatographic (HS-GC) method for determination of adhesive contaminants (microstickies) in recycled whitewater, a fiber containing process stream, in the paper mill. It is based on the adsorption behavior of toluene (as a tracer) on the hydrophobic surface of microstickies, which affects the apparent vapor-liquid...

  15. Devising an adjustable splitter for dual-column gas chromatography.

    PubMed

    Wang, Chieh-Heng; Chang, Chih-Chung; Wang, Jia-Lin

    2007-09-07

    A flow controlled adjustable splitter was configured from a Deans switch and employed in an automated dual column gas chromatographic (GC) system for analyzing mono-aromatic compounds. Volatile organic compounds (VOCs), thermally desorbed from the sorbent trap, were split by the adjustable splitter onto two columns of different phases for separation and then detection by flame ionization detection (FID). Unlike regular splitters in which the split ratio is passively determined by the diameter and/or length of the connecting columns or tubing, the split ratio in our adjustable splitter is controlled by the auxiliary flow in the Deans switch. The auxiliary flow serves as a gas plug on either side of the column for decreasing the sample flow in one transfer line, but increasing the flow in the other. By adjusting the auxiliary flow and therefore the size of the gas plug, the split ratio can be easily varied and favorable to the side of no auxiliary gas. As an illustration, two columns, DB-1 and Cyclodex-B, were employed in this study for separating benzene, toluene, ethylbenzene, xylenes, denoted as BTEX, in particular the structural isomers of o-, m-, p-xylenes. This configuration demonstrates that BTEX cannot be fully separated with either column, but can be deconvoluted by simple algebra if dual columns are used with a splitter. The applicability of the proposed concept was tested by analyzing a gas standard containing BTEX at different split ratios and with various sample sizes, all leading to a constant ratio of m-xylene versus p-xylene.

  16. Determination of Pyrrolnitrin and Derivatives by Gas-Liquid Chromatography

    PubMed Central

    Hamill, Robert L.; Sullivan, Hugh R.; Gorman, Marvin

    1969-01-01

    A gas-liquid chromatographic technique was applied to the separation of pyrrolnitrin and its derivatives. The simultaneous use of a flame detector and an electron capture detector made possible the distinction between the nitro derivatives of pyrrolnitrin and the other metabolites. The metabolites could be readily quantitated with the electron capture detector, offering a much more sensitive assay than the flame detector. PMID:5373671

  17. Construction of a thermodesorption injector for gas chromatography.

    PubMed

    Schröder, Wolfgang

    2011-02-01

    A detailed description for the do-it-yourself construction of a high-performance thermodesorption GC injector (HPTI) is presented. The injector consists of a heated desorption chamber, a cooled loop for focusing the desorbed volatiles as well as a heating control for sample injection into the separation column. The gas flow is controlled by valve switching during the steps of the operation. Two versions of the injector function either for the injection of highly volatile compounds or for compounds with extremely low volatility, e.g. lubricants. The sophisticated gas flow management allows injection of highly concentrated samples without memory effects in a sample gas split mode, while traces may be injected with virtually 1:1 sample transfer. A wide range of adsorbents appropriate for the compounds can be chosen due to homemade adsorbent tubes and the achievability of high desorption temperature. Solutions may be injected from a carrier material after solvent evaporation. The HPTI fulfills all multipurpose GC injector requirements and with the support of downloadable instruction files can be built by anyone working with conventional GC devices.

  18. Automated two-dimensional interface for capillary gas chromatography

    DOEpatents

    Strunk, M.R.; Bechtold, W.E.

    1996-02-20

    A multidimensional gas chromatograph (GC) system is disclosed which has wide bore capillary and narrow bore capillary GC columns in series and has a novel system interface. Heart cuts from a high flow rate sample, separated by a wide bore GC column, are collected and directed to a narrow bore GC column with carrier gas injected at a lower flow compatible with a mass spectrometer. A bimodal six-way valve is connected with the wide bore GC column outlet and a bimodal four-way valve is connected with the narrow bore GC column inlet. A trapping and retaining circuit with a cold trap is connected with the six-way valve and a transfer circuit interconnects the two valves. The six-way valve is manipulated between first and second mode positions to collect analyte, and the four-way valve is manipulated between third and fourth mode positions to allow carrier gas to sweep analyte from a deactivated cold trap, through the transfer circuit, and then to the narrow bore GC capillary column for separation and subsequent analysis by a mass spectrometer. Rotary valves have substantially the same bore width as their associated columns to minimize flow irregularities and resulting sample peak deterioration. The rotary valves are heated separately from the GC columns to avoid temperature lag and resulting sample deterioration. 3 figs.

  19. Automated two-dimensional interface for capillary gas chromatography

    DOEpatents

    Strunk, Michael R.; Bechtold, William E.

    1996-02-20

    A multidimensional gas chromatograph (GC) system having wide bore capillary and narrow bore capillary GC columns in series and having a novel system interface. Heart cuts from a high flow rate sample, separated by a wide bore GC column, are collected and directed to a narrow bore GC column with carrier gas injected at a lower flow compatible with a mass spectrometer. A bimodal six-way valve is connected with the wide bore GC column outlet and a bimodal four-way valve is connected with the narrow bore GC column inlet. A trapping and retaining circuit with a cold trap is connected with the six-way valve and a transfer circuit interconnects the two valves. The six-way valve is manipulated between first and second mode positions to collect analyte, and the four-way valve is manipulated between third and fourth mode positions to allow carrier gas to sweep analyte from a deactivated cold trap, through the transfer circuit, and then to the narrow bore GC capillary column for separation and subsequent analysis by a mass spectrometer. Rotary valves have substantially the same bore width as their associated columns to minimize flow irregularities and resulting sample peak deterioration. The rotary valves are heated separately from the GC columns to avoid temperature lag and resulting sample deterioration.

  20. Development of gas chromatography analysis of fatty acids in marine organisms.

    PubMed

    Tang, Baokun; Row, Kyung Ho

    2013-08-01

    The gas chromatographic analysis of fatty acids has attracted considerable interest. In this analysis, the common derivatives of fatty acids, such as fatty acid methyl esters, can be detected using a flame ionization detector and the mass spectra can indicate the true structure of fatty acids. This paper reviews gas chromatographic methods for obtaining fatty acids from marine organisms. The stationary phase and detector for applications in gas chromatography are discussed. This article also reviews the components of fatty acids in marine animals, marine plants and marine microorganisms.

  1. Determination of maximal amount of minor gases adsorbed in a shale sample by headspace gas chromatography.

    PubMed

    Zhang, Chun-Yun; Hu, Hui-Chao; Chai, Xin-Sheng; Pan, Lei; Xiao, Xian-Ming

    2014-02-07

    In this paper, we present a novel method for determining the maximal amount of ethane, a minor gas species, adsorbed in a shale sample. The method is based on the time-dependent release of ethane from shale samples measured by headspace gas chromatography (HS-GC). The study includes a mathematical model for fitting the experimental data, calculating the maximal amount gas adsorbed, and predicting results at other temperatures. The method is a more efficient alternative to the isothermal adsorption method that is in widespread use today. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Partition coefficients of organic compounds in new imidazolium based ionic liquids using inverse gas chromatography.

    PubMed

    Revelli, Anne-Laure; Mutelet, Fabrice; Jaubert, Jean-Noël

    2009-06-05

    Partition coefficients of organic compounds in four ionic liquids: 1-ethanol-3-methylimidazolium tetrafluoroborate, 1-ethanol-3-methylimidazolium hexafluorophosphate, 1,3-dimethylimidazolium dimethylphosphate and 1-ethyl-3-methylimidazolium diethylphosphate were measured using inverse gas chromatography from 303.3 to 332.55K. The influence of gas-liquid and gas-solid interfacial adsorption of different solutes on ionic liquids was also studied. Most of the polar solutes were retained largely by partition while light hydrocarbons were retained predominantly by interfacial adsorption on the ionic liquids studied in this work. The solvation characteristics of the ionic liquids were evaluated using the Abraham solvation parameter model.

  3. Metal-Organic Framework Thin Films as Stationary Phases in Microfabricated Gas-Chromatography Columns.

    SciTech Connect

    Read, Douglas; Sillerud, Colin Halliday

    2016-01-01

    The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; and the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.

  4. Kinetic efficiency of polar monolithic capillary columns in high-pressure gas chromatography.

    PubMed

    Kurganov, A A; Korolev, A A; Shiryaeva, V E; Popova, T P; Kanateva, A Yu

    2013-11-08

    Poppe plots were used for analysis of kinetic efficiency of monolithic sorbents synthesized in quartz capillaries for utilization in high-pressure gas chromatography. Values of theoretical plate time and maximum number of theoretical plates occurred to depend significantly on synthetic parameters such as relative amount of monomer in the initial polymerization mixture, temperature and polymerization time. Poppe plots let one to find synthesis conditions suitable either for high-speed separations or for maximal efficiency. It is shown that construction of kinetic Poppe curves using potential Van Deemter data demands compressibility of mobile phase to be taken into consideration in the case of gas chromatography. Model mixture of light hydrocarbons C1 to C4 was then used for investigation of influence of carrier gas nature on kinetic efficiency of polymeric monolithic columns. Minimal values of theoretical plate times were found for CO2 and N2O carrier gases. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Capillary gas-liquid chromatography separation of phenethylamines in amphetamine-positive urine samples.

    PubMed

    DePace, A; Verebey, K; elSohly, M

    1990-11-01

    Good gas chromatography (GC) separation of molecules is essential for clean gas chromatography/mass spectrometry (GC/MS) confirmation of compounds. The trifluoro derivatives of ephedrine (E) and methamphetamine (MA) coelute on dimethyl silicone capillary columns, such as DB-1, which are most commonly used by chromatographers. Methods are described to separate E and MA to aid GC/MS confirmations of methamphetamine, ephedrine, or both E and MA together, whichever may be present in Enzyme Immunoassay (EIA)-analyzed amphetamine-positive urine samples. The use of the heptafluoro derivatives of E and MA on a DB-1 column, or the trifluoro derivatives of E and MA on a DB-17 column, is suggested for good gas chromatographic separation.

  6. Bridging the gap between gas and liquid chromatography.

    PubMed

    Gritti, Fabrice; Fogwill, Michael; Gilar, Martin; Jarrell, Joseph A

    2016-11-11

    The rapid and complete baseline separation of both volatile (C5 to C16 alkanes in gasoline or terpenes in plant extracts) and non-volatile (>C20 alkanes) organic compounds was achieved by combining (1) low-density fluid chromatography (LDFC) using carbon dioxide at elevated temperature (>90°C) and low pressure (1500psi) designed to increase the retention of the most volatile compounds and (2) high-vacuum technology (<10(-4)Torr) in order to preserve the maximum efficiency of short analytical columns (3.0mm×150mm packed with 1.8μm fully porous HSS-SB-C18 particles) when used in LDFC. The volatile compounds are eluted first under isobaric conditions (1500psi) in less than a minute followed by a linear gradient of the column back pressure (from 1500 to 3500psi in 5min) for the elution of the non-volatile compounds up to C40. The experimental results demonstrate that LDFC performed with short 3.0mm i.d. columns packed with sub-2μm particles and placed under adiabatic conditions enables the analysts to deliver a single, fast, and high-resolution separation of both volatile and non-volatile compounds.

  7. CORRIGENDUM: Normalization of natural gas composition data measured by gas chromatography Normalization of natural gas composition data measured by gas chromatography

    NASA Astrophysics Data System (ADS)

    Milton, Martin J. T.; Harris, Peter M.; Brown, Andrew S.; Cowper, Chris J.

    2009-11-01

    The authors unintentionally omitted to mention work [1] that pre-dated the cited work by Haesselbarth and Bremser [2]. This work formulated the problem within a mathematical framework and had been cited by the authors in a previous publication [3]. The major conclusion of the authors' work goes beyond the mathematics presented in [1] and [2] because it is applied to several real data sets and the results are interpreted in practical terms. References [1] Haesselbarth W and Bremser W 2001 Correlation in natural gas composition data Proc. Int. Gas Research Conf. (Amsterdam) [2] Haesselbarth W and Bremser W 2007 Metrologia 44 128-45 [3] Brown A S, Milton M J T, Cowper C J, Squire G D, Bremser W and Branch R W 2004 J. Chromatogr. A 1040 215-25

  8. Theoretical and experimental study of recycle capillary gas chromatography with carrier gas propelled by a peristaltic pump.

    PubMed

    Kubinec, Róbert; Sevcík, Jirí; Górová, Renáta; Addová, Gabriela; Soják, Ladislav

    2003-04-18

    A new technique of recycle capillary gas chromatography (RCGC) characterized by a very high separation efficiency of more than 10(6) theoretical plates has been developed to solve the problem of separation of isomers with similar physico-chemical properties. The technique replaces the recycle valve by a peristaltic pump that propels the carrier gas. A general model has been developed for description of RCGC characteristics and experimentally verified on the retention behaviour of methane and the separation of a test pair of 3-methyl-1-butene and 2-methylbutane.

  9. On the two-domain equations for gas chromatography.

    SciTech Connect

    Romero, Louis Anthony; Parks, Michael L.

    2009-01-01

    We present an analysis of gas chromatographic columns where the stationary phase is not assumed to be a thin uniform coating along the walls of the cross section. We also give an asymptotic analysis assuming that the parameter {beta} = KD{sup II}{rho}{sup II}/D{sup I}{rho}{sup I} is small. Here K is the partition coefficient, and D{sup i} and {rho}{sup i}, i = I, II are the diffusivity and density in the mobile (i = I) and stationary (i = II) regions.

  10. Experimental adsorption isotherms based on inverse gas chromatography.

    PubMed

    Kalogirou, E; Bassiotis, I; Artemiadi, Th; Margariti, S; Siokos, V; Roubani-Kalantzopoulou, F

    2002-09-06

    A new chromatographic perturbation method is used for studying the adsorption-desorption equilibrium in various gas-solid heterogeneous systems. It is the reversed-flow method giving accurate and precise values of many physicochemical constants including the basic and necessary adsorption isotherm values. For four inorganic oxides, namely, Cr2O3, Fe2O3, TiO2 and PbO, and two aromatic hydrocarbons (benzene, toluene) these adsorption isotherms have been determined through a non-linear model.

  11. Pioneer Venus gas chromatography of the lower atmosphere of Venus

    NASA Technical Reports Server (NTRS)

    Oyama, V. I.; Carle, G. C.; Woeller, F.; Pollack, J. B.; Reynolds, R. T.; Craig, R. A.

    1980-01-01

    A gas chromatograph mounted in the Pioneer Venus sounder probe measured the chemical composition of the atmosphere of Venus at three altitudes. Ne, N2, O2, Ar, CO, H2O, SO2, and CO2 were measured, and upper limits set for H2, COS, H2S, CH4, Kr, N2O, C2H4, C2H6, and C3H8. Simulation studies have provided indirect evidence for sulfuric acid-like droplets and support the possibility of water vapor at altitudes of 42 and 24 km. The paper discusses the implications of these results for the origin, evolution, and present state of Venus' atmosphere.

  12. Pioneer Venus gas chromatography of the lower atmosphere of Venus

    NASA Technical Reports Server (NTRS)

    Oyama, V. I.; Carle, G. C.; Woeller, F.; Pollack, J. B.; Reynolds, R. T.; Craig, R. A.

    1980-01-01

    A gas chromatograph mounted in the Pioneer Venus sounder probe measured the chemical composition of the atmosphere of Venus at three altitudes. Ne, N2, O2, Ar, CO, H2O, SO2, and CO2 were measured, and upper limits set for H2, COS, H2S, CH4, Kr, N2O, C2H4, C2H6, and C3H8. Simulation studies have provided indirect evidence for sulfuric acid-like droplets and support the possibility of water vapor at altitudes of 42 and 24 km. The paper discusses the implications of these results for the origin, evolution, and present state of Venus' atmosphere.

  13. Analysis of phytosterols and phytostanols in enriched dairy products by Fast gas chromatography with mass spectrometry.

    PubMed

    Inchingolo, Raffaella; Cardenia, Vladimiro; Rodriguez-Estrada, Maria Teresa

    2014-10-01

    A Fast gas chromatography and mass spectrometry method for plant sterols/stanols analysis was developed, using a short capillary gas chromatography column (10 m × 0.1 mm internal diameter × 0.1 μm film thickness) coated with 5% diphenyl-polysiloxane. A silylated mixture of the main plant sterols/stanols standards (β-sitosterol, campesterol, stigmasterol, campestanol, sitostanol) was well separated in 1.5 min, with a good peak resolution (>1.4, determined on a critical chromatographic peak pair (β-sitosterol and sitostanol)), repeatability (<13%), and sensitivity (<0.017 ng/mL). The suitability of this Fast chromatography method was tested on plant sterols/stanols-enriched dairy products (yogurt and milk), which were subjected to lipid extraction, cold saponification, and silylation prior to injection. The analytical performance (sensitivity < 0.256 ng/mL and repeatability < 10.36%) and significant reduction of the analysis time and consumables demonstrate that Fast gas chromatography-mass spectrometry method could be also employed for the plant sterols/stanols analysis in functional dairy products. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Assessment of the chemical changes during storage of phenol-formaldehyde resins pyrolysis gas chromatography mass spectrometry, inverse gas chromatography and Fourier transform infra red methods.

    PubMed

    Strzemiecka, B; Voelkel, A; Zięba-Palus, J; Lachowicz, T

    2014-09-12

    The chemical changes occurring in the phenol-formaldehyde resins (resol and novolac type) during their storage were investigated. In this paper the FT-IR, py-GCMS and inverse gas chromatography methods were applied for assessment of the changes occurring during storage of the phenolic resins. We have found that during storage some examined resins occurred partial curing. The results from all techniques applied are consistent. Py-GCMS is useful technique for screening the storage processes but IGC seems to be most sensitive one.

  15. Identification of Abscisic Acid in Tulipa gesneriana L. by Gas-Liquid Chromatography with Electron Capture and Combined Gas-Liquid Chromatography and Mass Spectrometry

    PubMed Central

    Terry, Paul H.; Aung, Louis H.; De Hertogh, August A.

    1982-01-01

    A major growth inhibitory substance of tulip bulbs (Tulipa gesneriana L. cv Paul Richter) has been unequivocally shown to be abscisic acid (ABA). The ABA methyl ester of the free ether-soluble acid fractions of tulip organs had the identical retention time on gas-liquid chromatography with electron capture detector as authentic ABA methyl ester. In addition, the mass spectra were the same. On a unit dry matter basis, the basalplate and floral shoot contained 3.6 and 2.6 times more ABA than the fleshy scales, respectively. PMID:16662721

  16. [Assay of plasma dehydroepiandrosterone sulfate by gas chromatography with electron-capture detection].

    PubMed

    Oui, E; Habrioux, G; Mathian, B; Revol, A; Henry, R

    1986-01-01

    A sensitive and specific method for the determination of plasma S-DHA by gas chromatography (GC), with fused silica capillary column (stationary phase SE 54) and electron capture, after solvolysis of the sample and purification by high performance liquid chromatography (HPLC) is described. The interest of the new internal standard (5 alpha androst-9(11)-ene-3 beta ol-17-one) for the determination of the DHA by GC is shown. The analytical characteristics of this method as well as a comparative study of the values obtained by this method and by radioimmuno-assay are described.

  17. Determination of free fatty acids and triglycerides by gas chromatography using selective esterification reactions.

    PubMed

    Kail, Brian W; Link, Dirk D; Morreale, Bryan D

    2012-01-01

    A method for selectively determining both free fatty acids (FFA) and triacylglycerides (TAGs) in biological oils was investigated and optimized using gas chromatography after esterification of the target species to their corresponding fatty acid methyl esters (FAMEs). The method used acid catalyzed esterification in methanolic solutions under conditions of varying severity to achieve complete conversion of more reactive FFAs while preserving the concentration of TAGs. Complete conversion of both free acids and glycerides to corresponding FAMEs was found to require more rigorous reaction conditions involving heating to 120°C for up to 2 h. Method validation was provided using gas chromatography-flame ionization detection, gas chromatography-mass spectrometry, and liquid chromatography-mass spectrometry. The method improves on existing methods because it allows the total esterified lipid to be broken down by FAMEs contributed by FFA compared to FAMEs from both FFA and TAGs. Single and mixed-component solutions of pure fatty acids and triglycerides, as well as a sesame oil sample to simulate a complex biological oil, were used to optimize the methodologies. Key parameters that were investigated included: HCl-to-oil ratio, temperature and reaction time. Pure free fatty acids were found to esterify under reasonably mild conditions (10 min at 50°C with a 2.1:1 HCl to fatty acid ratio) with 97.6 ± 2.3% recovery as FAMEs, while triglycerides were largely unaffected under these reaction conditions. The optimized protocol demonstrated that it is possible to use esterification reactions to selectively determine the free acid content, total lipid content, and hence, glyceride content in biological oils. This protocol also allows gas chromatography analysis of FAMEs as a more ideal analyte than glyceride species in their native state.

  18. Application of Headspace Solid Phase Microextraction and Gas Chromatography/Mass Spectrometry for Rapid Detection of the Chemical Warfare Agent Sulfur Mustard

    DTIC Science & Technology

    2002-05-16

    Title of Thesis: “Application of Headspace Solid Phase Microextraction and Gas Chromatography/Mass Spectrometry for Rapid...TITLE AND SUBTITLE Application of Headspace Solid Phase Microextraction and Gas Chromatography/Mass Spectrometry for Rapid Detection of the Chemical...phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS). Five commercially available SPME fibers were investigated to determine the

  19. Qualitative Gas Chromatography-Mass Spectrometry Analyses Using Amines as Chemical Ionization Reagent Gases

    NASA Astrophysics Data System (ADS)

    Little, James L.; Howard, Adam S.

    2013-12-01

    Ammonia is a very useful chemical ionization (CI) reagent gas for the qualitative analyses of compounds by positive ion gas chromatography-mass spectrometry (GCMS). The gas is readily available, inexpensive, and leaves no carbon contamination in the MS source. Compounds of interest to our laboratory typically yield abundant protonated or ammoniated species, which are indicative of a compound's molecular weight. Nevertheless, some labile compounds fragment extensively by substitution and elimination reactions and yield no molecular weight information. In these cases, a CI reagent gas mixture of methylamine in methane prepared dynamically was found to be very useful in obtaining molecular weight data. Likewise, deuterated ammonia and deuterated methylamine are useful CI reagent gases for determining the exchangeable protons in organic compounds. Deuterated methylamine CI reagent gas is conveniently prepared by dynamically mixing small amounts of methylamine with excess deuterated ammonia.

  20. Determination of phenoxy acid herbicides in water by electron-capture and microcoulometric gas chromatography

    USGS Publications Warehouse

    Goerlitz, D.F.; Lamar, William L.

    1967-01-01

    A sensitive gas chromatographic method using microcoulometric titration and electron-capture detection for the analysis of 2,4-D, silvex, 2,4,5-T, and other phenoxy acid herbicides in water is described. The herbicides are extracted from unfiltered water samples (800-1,000 ml) by use of ethyl ether ; then the herbicides are concentrated and esterilied. To allow the analyst a choice, two esterilication procedures--using either boron trifluoride-methanol or diazomethane--are evaluated. Microcoulometric gas chromatography is specific for the detection of halogenated compounds such as the phenoxy acid herbicides whereas it does not respond to nonhalogenated components. Microcoulometric gas chromatography requires care and patience. It is not convenient for rapid screening of l-liter samples that contain less than 1 microgram of the herbicide. Although electroncapture gas chromatography is less selective and more critically affected by interfering substances, it is, nevertheless, convenient and more sensitive than microcoulometric gas chromatography. Two different liquid phases are used in the gas chromatographic columns--DC-200 silicone in one column and QF-1 silicone in the other. The performance of both columns is improved by the addition of Carbowax 20M. The Gas Chrom Q support is coated with the liquid phases by the 'frontal-analysis' technique. The practical lower limits for measurement of the phenoxy acid herbicides in water primarily depend upon the sample size, interferences present, anal instrumentation used. With l-liter samples of water, the practical lower limits of measurement are 10 ppt (parts per trillion) for 2,4-D and 2 ppt for silvex and 2,4,5-T when electron-capture detection is used, and approximately 20 ppt for each herbicide when analyzed by microcoulometric-titration gas chromatography. Recoveries of the herbicides immediately after addition to unfiltered water samples averaged 92 percent for 2,4-D, 90 percent for silvex, and 98 percent for 2

  1. Venus lower atmospheric composition - Analysis by gas chromatography

    NASA Technical Reports Server (NTRS)

    Oyama, V. I.; Carle, G. C.; Woeller, F.; Pollack, J. B.

    1979-01-01

    The first gas chromatographic analysis of the lower atmosphere of Venus is reported. Three atmospheric samples were analyzed. The third of these samples showed carbon dioxide (96.4 percent), molecular nitrogen (3.41 percent), water vapor (0.135 percent), molecular oxygen (69.3 ppm), argon (18.6 ppm), neon (4.31 ppm), and sulfur dioxide (186 ppm). The amounts of water vapor and sulfur dioxide detected are roughly compatible with the requirements of greenhouse models of the high surface temperature of Venus. The large positive gradient of sulfur dioxide, molecular oxygen, and water vapor from the cloud tops to their bottoms, as implied by Earth-based observations and these results, gives added support for the presence of major quantities of aqueous sulfuric acid in the clouds. A comparison of the inventory of inert gases found in the atmospheres of Venus, Earth, and Mars suggests that these components are due to outgassing from the planetary interiors.

  2. Determination of microstickies in recycled whitewater by headspace gas chromatography.

    PubMed

    Chai, X-S; Samp, J C; Yang, Q F; Song, H N; Zhang, D C; Zhu, J Y

    2006-03-03

    This study proposed a novel headspace gas chromatographic (HS-GC) method for determination of adhesive contaminants (microstickies) in recycled whitewater, a fiber containing process stream, in the paper mill. It is based on the adsorption behavior of toluene (as a tracer) on the hydrophobic surface of microstickies, which affects the apparent vapor-liquid equilibration partitioning of toluene. It was found that the equilibrium concentration of toluene in the vapor phase is inversely proportional to the apparent effective surface area of microstickies that remain in the corresponding solution. Thus, the amount of microsticky materials in the recycled whitewater can be quantified by HS-GC via indirect measurement of the toluene content in the vapor phase of the sample without any pretreatment. The presented method is simple, rapid and automated.

  3. Cyclopentadiene evolution during pyrolysis-gas chromatography of PMR polyimides

    NASA Technical Reports Server (NTRS)

    Alston, William B.; Gluyas, Richard E.; Snyder, William J.

    1992-01-01

    The effect of formulated molecular weight (FMW), extent of cure, and cumulative aging on the amount of cyclopentadiene (CPD) evolved from Polymerization of Monomeric Reactants (PMR) polyimides were investigated by pyrolysis-gas chromotography (PY-GC). The PMR polyimides are additional crosslinked resins formed from an aromatic diamine, a diester of an aromatic tetracarboxylic acid and a monoester of 5-norbornene-2, 3-dicarboxylic acid. The PY-GC results were related to the degree of crosslinking and to the thermo-oxidative stability (weight loss) of PMR polyimides. Thus, PY-GC has shown to be a valid technique for the characterization of PMR polyimide resins and composites via correlation of the CPD evolved versus the thermal history of the PMR sample.

  4. Novel fire investigation technique using needle extraction in gas chromatography.

    PubMed

    Ueta, Ikuo; Saito, Yoshihiro; Teraoka, Kenta; Matsuura, Hisashi; Fujimura, Koji; Jinno, Kiyokatsu

    2010-01-01

    A novel fire investigation technique using a needle extraction device was studied. Using a polymer particle-packed needle device, air samples containing volatile organic compounds (VOCs) generated from fire accelerants, gasoline and kerosene were extracted effectively, and subsequent gas chromatographic (GC) analyses were successfully carried out. Carpet and wood samples were spiked with gasoline and kerosene, followed by monitoring of the time-variation profiles of emitted VOCs up to 48 h. The fire accelerants were also measured for combusted carpet and wood samples, and the applicability of the proposed method to fire investigations was confirmed. Even at 48 h after spiking, groups of characteristic compounds were clearly observed in the air environments near the combusted sample. This method was further applied to the determination of VOCs in simulated fires, strongly suggesting the applicability of the developed method to real fire investigations.

  5. Venus lower atmospheric composition - Analysis by gas chromatography

    NASA Technical Reports Server (NTRS)

    Oyama, V. I.; Carle, G. C.; Woeller, F.; Pollack, J. B.

    1979-01-01

    The first gas chromatographic analysis of the lower atmosphere of Venus is reported. Three atmospheric samples were analyzed. The third of these samples showed carbon dioxide (96.4 percent), molecular nitrogen (3.41 percent), water vapor (0.135 percent), molecular oxygen (69.3 ppm), argon (18.6 ppm), neon (4.31 ppm), and sulfur dioxide (186 ppm). The amounts of water vapor and sulfur dioxide detected are roughly compatible with the requirements of greenhouse models of the high surface temperature of Venus. The large positive gradient of sulfur dioxide, molecular oxygen, and water vapor from the cloud tops to their bottoms, as implied by Earth-based observations and these results, gives added support for the presence of major quantities of aqueous sulfuric acid in the clouds. A comparison of the inventory of inert gases found in the atmospheres of Venus, Earth, and Mars suggests that these components are due to outgassing from the planetary interiors.

  6. Characterisation of beeswax in works of art by gas chromatography-mass spectrometry and pyrolysis-gas chromatography-mass spectrometry procedures.

    PubMed

    Bonaduce, Ilaria; Colombini, Maria Perla

    2004-03-05

    Pyrolysis (Py) with in situ derivatisation with hexamethyldisilazane-gas chroma-break tography-mass spectrometry (GC-MS) and a gas chromatography-mass spectrometry procedure based on microwave-assisted saponification were used to identify the organic components in small sized beeswax samples. With the latter procedure quantitative recoveries can be made and hydrocarbons, alcohols and omega-1-diols in the neutral fraction, and fatty acids and omega-1-hydroxy acids in the acidic fraction can be efficiently separated and detected. Both procedures were used to characterise a wax anatomic sculpture "The Plague" (1691-1694) by Gaetano Zumbo, resulting in the identification of beeswax and a Pinaceae resin. The GC-MS analysis brought to light some essential differences in beeswax composition between the raw material and the old modelled wax thus giving some clear indications about the recipe used by the sculptor.

  7. Analysis and deconvolution of dimethylnaphthalene isomers using gas chromatography vacuum ultraviolet spectroscopy and theoretical computations.

    PubMed

    Schenk, Jamie; Mao, James X; Smuts, Jonathan; Walsh, Phillip; Kroll, Peter; Schug, Kevin A

    2016-11-16

    An issue with most gas chromatographic detectors is their inability to deconvolve coeluting isomers. Dimethylnaphthalenes are a class of compounds that can be particularly difficult to speciate by gas chromatography - mass spectrometry analysis, because of their significant coelution and similar mass spectra. As an alternative, a vacuum ultraviolet spectroscopic detector paired with gas chromatography was used to study the systematic deconvolution of mixtures of coeluting isomers of dimethylnaphthalenes. Various ratio combinations of 75:25; 50:50; 25:75; 20:80; 10:90; 5:95; and 1:99 were prepared to test the accuracy, precision, and sensitivity of the detector for distinguishing overlapping isomers that had distinct, but very similar absorption spectra. It was found that, under reasonable injection conditions, all of the pairwise overlapping isomers tested could be deconvoluted up to nearly two orders of magnitude (up to 99:1) in relative abundance. These experimental deconvolution values were in agreement with theoretical covariance calculations performed for two of the dimethylnaphthalene isomers. Covariance calculations estimated high picogram detection limits for a minor isomer coeluting with low to mid-nanogram quantity of a more abundant isomer. Further characterization of the analytes was performed using density functional theory computations to compare theory with experimental measurements. Additionally, gas chromatography - vacuum ultraviolet spectroscopy was shown to be able to speciate dimethylnaphthalenes in jet and diesel fuel samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    PubMed

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Analysis of trapped gas in 1E34 detonators by gas chromatography

    SciTech Connect

    Warner, D.K.; Back, P.S.; Barnhart, B.V.

    1980-05-14

    A method was developed to extract and then analyze gas trapped in thermally aged 1E34 detonators. This gas was extracted into an evacuated volume and injected into a gas chromatograph for separation and quantitative analysis. To effect this gas extraction, a device was designed for puncturing the detonator cup and capturing the effused gas. Limited testing of five detonators in this device shows amounts of gas ranging from about 0.5 X 10 {sup -7} to 12 X 10 {sup - 7} moles.

  10. Fabry-Pérot cavity sensors for multipoint on-column micro gas chromatography detection.

    PubMed

    Liu, Jing; Sun, Yuze; Howard, Daniel J; Frye-Mason, Greg; Thompson, Aaron K; Ja, Shiou-Jyh; Wang, Siao-Kwan; Bai, Mengjun; Taub, Haskell; Almasri, Mahmoud; Fan, Xudong

    2010-06-01

    We developed and characterized a Fabry-Pérot (FP) sensor module based micro gas chromatography (microGC) detector for multipoint on-column detection. The FP sensor was fabricated by depositing a thin layer of metal and a layer of gas-sensitive polymer consecutively on the endface of an optical fiber, which formed the FP cavity. Light partially reflected from the metal layer and the polymer-air interface generated an interference spectrum, which shifted as the polymer layer absorbed the gas analyte. The FP sensor module was then assembled by inserting the FP sensor into a hole drilled in the wall of a fused-silica capillary, which can be easily connected to the conventional gas chromatography (GC) column through a universal quick seal column connector, thus enabling on-column real-time detection. We characterized the FP sensor module based microGC detector. Sensitive detection of various gas analytes was achieved with subnanogram detection limits. The rapid separation capability of the FP sensor module assembled with both single- and tandem-column systems was demonstrated, in which gas analytes having a wide range of polarities and volatilities were well-resolved. The tandem-column system obtained increased sensitivity and selectivity by employing two FP sensor modules coated with different polymers, showing great system versatility.

  11. Investigation of combwax of honeybees with high-temperature gas chromatography and high-temperature gas chromatography-chemical ionization mass spectrometry. II: High-temperature gas chromatography-chemical ionization mass spectrometry.

    PubMed

    Aichholz, R; Lorbeer, E

    2000-06-23

    Crude combwax of six various honey bee species have been analyzed by high-temperature gas chromatography (HTGC)-chemical ionization mass spectrometry after a two-step silylation procedure. An optimized chromatographic procedure, described previously, enables the separation of high-molecular mass lipid compounds resulting in a characteristic fingerprint of the combwaxes of different honeybee species. The coupling of HTGC to mass spectrometry requires appropriate instrumentation in order to achieve sufficient sensitivity at high elution temperatures and avoid loss of chromatographic resolution. Chemical ionization was carried out using methane as reagent gas in order to determine the molecular mass of the individual compounds by means of abundant quasi molecular ions. To confirm the presence of unsaturated wax esters, ammonia was used as reagent gas. More than 80 lipid constituents were separated and characterized by their mass spectra. Representative chemical ionization mass spectra of individual compounds are presented. Both, HTGC-flame ionization detection data and the results of the HTGC-mass spectrometric investigations enabled a rapid profiling of the individual classes of compounds in crude combwaxes.

  12. Steroid profiling by gas chromatography-mass spectrometry and high performance liquid chromatography-mass spectrometry for adrenal diseases.

    PubMed

    McDonald, Jeffrey G; Matthew, Susan; Auchus, Richard J

    2011-12-01

    The ability to measure steroid hormone concentrations in blood and urine specimens is central to the diagnosis and proper treatment of adrenal diseases. The traditional approach has been to assay each steroid hormone, precursor, or metabolite using individual aliquots of serum, each with a separate immunoassay. For complex diseases, such as congenital adrenal hyperplasia and adrenocortical cancer, in which the assay of several steroids is essential for management, this approach is time consuming and costly, in addition to using large amounts of serum. Gas chromatography/mass spectrometry profiling of steroid metabolites in urine has been employed for many years but only in a small number of specialized laboratories and suffers from slow throughput. The advent of commercial high-performance liquid chromatography instruments coupled to tandem mass spectrometers offers the potential for medium- to high-throughput profiling of serum steroids using small quantities of sample. Here, we review the physical principles of mass spectrometry, the instrumentation used for these techniques, the terminology used in this field and applications to steroid analysis.

  13. Gas chromatography-mass spectrometry and high-performance liquid chromatography-diode array detection for dating of paper ink.

    PubMed

    Díaz-Santana, Oscar; Vega-Moreno, Daura; Conde-Hardisson, Francisco

    2017-09-15

    An extraction and determination method is shown for the analysis of dyes and solvents present in two types of ballpoint pen inks that are deposited onto paper. Ink extracts are analysed using a combination of gas chromatography with mass spectrometry (GC-MS), and high-pressure liquid chromatography with photodiode array detection (HPLC-DAD), within a single sample extraction procedure. Seventeen solvents and thirteen dyes contained in two Montblanc(®) inks (black and blue) were monitored for 45 months at monthly intervals, in order to determine variations in the concentrations of the compounds over time. We also studied the relative variations between different compounds and the generation of degradation products such as phenol. The concentration data obtained from these compounds during their exposure have been analysed and a multiple regression model is developed for each ink type that allows an estimate of the exposure time of the ink on paper with a maximum error of between 4 and 7 months. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Broad range analysis of endocrine disruptors and pharmaceuticals using gas chromatography and liquid chromatography tandem mass spectrometry.

    PubMed

    Trenholm, Rebecca A; Vanderford, Brett J; Holady, Janie C; Rexing, David J; Snyder, Shane A

    2006-12-01

    Endocrine disrupting compounds (EDCs) and pharmaceuticals and personal care products (PPCPs) have been globally detected in impacted natural waters. The detection of trace quantities of EDCs and PPCPs in the environment is of great concern since some of these compounds have known physiological responses at low concentrations. EDCs can have a wide range of polarities, acidic and basic moieties, and exist in trace quantities, which often requires numerous complex extractions, large sample collection volumes, and multiple instrumental analyses. A comprehensive method has been developed allowing for the analysis of 58 potential EDCs in various water matrices using a single solid-phase extraction (SPE) of a 1L sample with subsequent analyses using both gas chromatography and liquid chromatography, each coupled with tandem mass spectrometry (GC-MS/MS and LC-MS/MS). Instrument detection limits ranged between 0.12-7.5 pg with corresponding method reporting limits of 1-10 ng l(-1) in water. Recoveries for most compounds were between 50% and 112% with good reproducibility (RSD 6-22%).

  15. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses.

    PubMed

    Muthukrishnan, Suriyavathana; Palanisamy, Subha; Subramanian, Senthilkumar; Selvaraj, Sumathi; Mari, Kavitha Rani; Kuppulingam, Ramalingam

    2016-08-01

    Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV) were identified by using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS) analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. The HPLC analysis of ELEV showed the presence of gallic and caffeic acids as the major components at concentrations of 2.0 ppm and 0.1 ppm, respectively, as well as other components. GC-MS analysis revealed the presence of 3-eicosyne; 3,7,11,15-tetramethyl-2-hexadecen-1-ol; butanoic acid, 3-methyl-3,7-dimethyl-6-octenyl ester; phytol; 1,2-benzenedicarboxylic acid, diundecyl ester; 1-octanol, 2-butyl-; squalene; and 2H-pyran, 2-(7-heptadecynyloxy) tetrahydro-derivative. Because pharmacopuncture is a new evolving natural mode that uses herbal extracts for treating patients with various ailments with minimum pain and maximum effect, the results of this study are particularly important and show that ELEV possesses a wide range of phytochemical constituents, as indicated above, as effective active principle molecules that can be used individually or in combination to treat patients with various diseases.

  16. Classification of natural resins by liquid chromatography-mass spectrometry and gas chromatography-mass spectrometry using chemometric analysis.

    PubMed

    Rhourrhi-Frih, B; West, C; Pasquier, L; André, P; Chaimbault, P; Lafosse, M

    2012-09-21

    Twenty-six resins from six botanical sources belonging to the class Magnoliopsida were compared based on gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry data. The extracts were analysed by GC after silylation and by reversed phase LC combined with atmospheric pressure photoionisation (APPI) mass spectrometry. The chromatograms were re-organized in data matrices, where each sample was represented by a single column comprising 2755 observations (intensity, time, m/z) in GC-MS and 360 observations in LC-MS. A simple comparison of resin fingerprints was attempted by organizing data according to a three dimensional bubble chart (retention time against m/z where each point was a bubble which size represented the ion intensity) where it is possible to easily superimpose the fingerprints. Thus the common and different species can be easily observed enabling to classify the resins. Hierarchical cluster analysis based on characteristics of GC-MS and LC-MS profiles affords a complete description of the classes of the resins and shows that 26 resins are divided into five main clusters Commiphora mukul, Daniella oliveri, Gardenia gummifera, Canarium madagascariensis, Boswellia dalzielii and Boswellia serrata, respectively. In conclusion, the proposed method has been applied to three other resinous samples from the Burseraceae family to evaluate their alteration state.

  17. Levels of phytosterol oxides in enriched and nonenriched spreads: application of a thin-layer chromatography-gas chromatography methodology.

    PubMed

    Conchillo, Ana; Cercaci, Luisito; Ansorena, Diana; Rodriguez-Estrada, Maria Teresa; Lercker, Giovanni; Astiasarán, Iciar

    2005-10-05

    The content of phytosterol oxidation products (POPs) in enriched and nonenriched commercial spreads was evaluated by thin-layer chromatography-gas chromatography (TLC-GC). Oxides of beta-sitosterol, campesterol, and stigmasterol were produced by thermo-oxidation (7-hydroxy, 7-keto, and epoxy derivatives) and chemical synthesis (triol derivatives), which were then separated and identified by TLC-GC. Their identification was further confirmed by GC-mass spectrometry (GC-MS). The total amounts of phytosterols found were 6.07 and 0.33 g/100 g of sample in phytosterol-enriched and nonenriched spread, respectively, whereas the total POPs contents were 45.60 and 13.31 mg/kg of sample in the enriched and nonenriched products. The main POPs found were the 7-keto derivatives of all phytosterols analyzed; 7-ketositosterol was the most abundant one (14.96 and 5.93 mg/kg of sample in phytosterol-enriched and nonenriched spread). No beta-epoxy and triol derivatives were detected in both types of samples. The enriched spread presented a lower phytosterol oxidation rate (0.07%) than the nonenriched one (0.41%).

  18. Multiresidue determination of 19 fungicides in processed fruits and vegetables by capillary gas chromatography after gel permeation chromatography.

    PubMed

    Sannino, A; Bandini, M; Bolzoni, L

    1999-01-01

    A gas chromatographic (GC) method was developed for simultaneous determination of 19 fungicides (chlorothalonil, vinclozolin, dichlofuanid, triadimefon, penconazole, chlozolinate, captan, procymidone, triadimenol, folpet, hexaconazole, myclobutanil, cyproconazole, propiconazole, nuarimol, captafol, iprodione, fenarimol, and bitertanol) and the acaricide tetradifon in tomato puree, peach nectar, orange juice, and canned peas. Samples were extracted with acetone, partitioned with ethyl acetate-cyclohexane (50 + 50, v/v), and cleaned using gel permeation chromatography with ethyl acetate-cyclohexane (50 + 50, v/v) as eluant. The final extract was analyzed by GC with ion trap mass spectrometry (ITMS) using a DB5 capillary column. Recoveries from fortified samples ranged from 74.6 to 99.3%, except for triadimenol and bitertanol. Quantitation limits for most analytes were between 0.005 and 0.050 mg/kg. The purified extracts were analyzed further by GC with electron capture and nitrogen phosphorus detection, and the results were compared with those obtained by ITMS.

  19. Comparison between high-performance liquid chromatography and gas chromatography methods for fatty acid identification and quantification in potato crisps.

    PubMed

    Sanches-Silva, A; Rodríguez-Bernaldo de Quirós, A; López-Hernández, J; Paseiro-Losada, P

    2004-04-02

    A reversed-phase high performance liquid chromatographic (RP-HLPC) method was compared with a gas chromatography-flame ionization detection (GC-FID) method for determining fatty acids in potato crisps. Different extraction procedures were used. Fatty acids were quantified by linear regression. Both methods presented good precision (R.S.D. < or = 5.88%) and recovery (> or = 82.31%). The precision using HPLC method was slightly better than for GC-FID method. There was good agreement between the fatty acid composition of potato crisps analysed by both methods. For most purposes the HPLC method would be better. However, when more fatty acids need to be analysed, GC is a more suitable method.

  20. Development, validation and determination of multiclass pesticide residues in cocoa beans using gas chromatography and liquid chromatography tandem mass spectrometry.

    PubMed

    Zainudin, Badrul Hisyam; Salleh, Salsazali; Mohamed, Rahmat; Yap, Ken Choy; Muhamad, Halimah

    2015-04-01

    An efficient and rapid method for the analysis of pesticide residues in cocoa beans using gas and liquid chromatography-tandem mass spectrometry was developed, validated and applied to imported and domestic cocoa beans samples collected over 2 years from smallholders and Malaysian ports. The method was based on solvent extraction method and covers 26 pesticides (insecticides, fungicides, and herbicides) of different chemical classes. The recoveries for all pesticides at 10 and 50 μg/kg were in the range of 70-120% with relative standard deviations of less than 20%. Good selectivity and sensitivity were obtained with method limit of quantification of 10 μg/kg. The expanded uncertainty measurements were in the range of 4-25%. Finally, the proposed method was successfully applied for the routine analysis of pesticide residues in cocoa beans via a monitoring study where 10% of them was found positive for chlorpyrifos, ametryn and metalaxyl. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Study of the microbiodegradation of terpenoid resin-based varnishes from easel painting using pyrolysis-gas chromatography-mass spectrometry and gas chromatography-mass spectrometry.

    PubMed

    Doménech-Carbó, María Teresa; Osete-Cortina, Laura; de la Cruz Cañizares, Juana; Bolívar-Galiano, Fernando; Romero-Noguera, Julio; Fernández-Vivas, María Antonia; Martín-Sánchez, Inés

    2006-08-01

    The alterations produced by microbiological attack on terpenoid resin-based varnishes from panel and canvas paintings have been evaluated using pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) and gas chromatography-mass spectrometry (GC-MS). The proposed methods include the on-line derivatisation of drying oils and diterpenoid resins using hexamethyldisilazane during pyrolysis and the application of methyl chloroformate as a derivatisation reagent for triterpenoid resins in GC-MS. Two types of specimens, consisting of model oil medium prepared from linseed oil and model spirit varnishes prepared from colophony and mastic resins dissolved in turpentine, have been used as reference materials. For a series of specimens upon which different genera of bacteria and fungi were inoculated and encouraged to grow, analyses indicated that no mechanisms that commonly occur during the attack of enzymes on drying oils and terpenoid biodegraders were observed to occur in the oil medium and varnishes studied. Thus, the degradation pathways observed in the performed trials usually occur as consequence of natural ageing. Specific trials consisting of the application of biocides to uninoculated colophony varnish resulted in the identification of processes that produce undesirable degradation of the varnish due to interactions between the biocide and the varnish components. Finally, the studied biocides--Biotin, New-Des and Nipagine--generally exhibited good inhibiting effects on the microorganisms studied, although some interesting differences were found between them regarding the application method and type of biocide.

  2. Evaluation of leaf-derived extracts as an environmentally sustainable source of essential oils by using gas chromatography-mass spectrometry and enantioselective gas chromatography-olfactometry.

    PubMed

    d'Acampora Zellner, Barbara; Lo Presti, Maria; Barata, Lauro Euclides Soares; Dugo, Paola; Dugo, Giovanni; Mondello, Luigi

    2006-02-01

    In consideration of the world's present environmental situation and the threat of species extinction, investigations concerning alternative sustainable sources of natural substances represent an extremely important issue. In this respect, the present research is focused on the analytical evaluation of Brazilian rosewood (Aniba rosaeodora Ducke) leaves, as an alternative source (with respect to wood) of rosewood essential oil and, as such, of natural linalool, which is extensively used in perfumery. Enantioselective-gas chromatography-olfactometry (Es-GC-O) was used as a tool for the simultaneous stereodifferentiation and olfactive evaluation of the volatile optically active components present in the analyzed samples. In addition to Es-GC-O analyses, direct olfactive analyses were also performed, enabling the evaluation of the global aroma exerted by each sample and the influence of each linalool antipode, as also other minor compounds. The samples were also submitted to gas chromatography-mass spectrometric analysis, thus establishing their chemical profiles. The assessment of enantiopure chiral compounds through Es-GC-O, along with direct olfactive analyses, confirmed that the leaves are a potential substituent for wood in the extraction of Brazilian rosewood essential oil, representing a sustainable nonwood source of natural linalool.

  3. Elucidation of the aroma compositions of Zhenjiang aromatic vinegar using comprehensive two dimensional gas chromatography coupled to time-of-flight mass spectrometry and gas chromatography-olfactometry.

    PubMed

    Zhou, Zhilei; Liu, Shuangping; Kong, Xiangwei; Ji, Zhongwei; Han, Xiao; Wu, Jianfeng; Mao, Jian

    2017-03-03

    In this work, a method to characterize the aroma compounds of Zhenjiang aromatic vinegar (ZAV) was developed using comprehensive two dimensional gas chromatography (GC×GC) coupled with time-of-flight mass spectrometry (TOFMS) and gas chromatography olfactometry (GC-O). The column combination was optimized and good separation was achieved. Structured chromatograms of furans and pyrazines were obtained and discussed. A total of 360 compounds were tentatively identified based on mass spectrum match factors, structured chromatogram and linear retention indices comparison. The most abundant class in number was ketones. A large number of esters, furans and derivatives, aldehydes and alcohols were also detected. The odor-active components were identified by comparison of the reported odor of the identified compounds with the odor of corresponding GC-O region. The odorants of methanethiol, 2-methyl-propanal, 2-methyl-butanal/3-methyl-butanal, octanal, 1-octen-3-one, dimethyl trisulfide, trimethyl-pyrazine, acetic acid, 3-(methylthio)-propanal, furfural, benzeneacetaldehyde, 3-methyl-butanoic acid/2-methyl-butanoic acid and phenethyl acetate were suspected to be the most potent. About half of them were identified as significant aroma constituents in ZAV for the first time. Their contribution to specific sensory attribute of ZAJ was also studied. The results indicated that the presented method is suitable for characterization of ZAV aroma constituents. This study also enriches our knowledge on the components and aroma of ZAV. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Impact of gas chromatography and mass spectrometry combined with gas chromatography and olfactometry for the sex differentiation of Baccharis articulata by the analysis of volatile compounds.

    PubMed

    Minteguiaga, Manuel; Umpiérrez, Noelia; Fariña, Laura; Falcão, Manuel A; Xavier, Vanessa B; Cassel, Eduardo; Dellacassa, Eduardo

    2015-09-01

    The Baccharis genus has more than 400 species of aromatic plants. However, only approximately 50 species have been studied in oil composition to date. From these studies, very few take into consideration differences between male and female plants, which is a significant and distinctive factor in Baccharis in the Asteraceae family. Baccharis articulata is a common shrub that grows wild in south Brazil, northern and central Argentina, Bolivia, Paraguay and Uruguay. It is considered to be a medicinal plant and is employed in traditional medicine. We report B. articulata male and female volatile composition obtained by simultaneous distillation-extraction technique and analyzed by gas chromatography with mass spectrometry. Also, an assessment of aromatic differences between volatile extracts was evaluated by gas chromatography with olfactometry. The results show a very similar chemical composition between male and female extracts, with a high proportion of terpene compounds of which β-pinene, limonene and germacrene D are the main components. Despite the chemical similarity, great differences in aromatic profile were found: male plant samples exhibited the strongest odorants in number and intensity of aromatic attributes. These differences explain field observations which indicate differences between male and female flower aroma, and might be of ecological significance in the attraction of pollinating insects. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Headspace-solid phase microextraction coupled to gas chromatography-combustion-isotope ratio mass spectrometer and to enantioselective gas chromatography for strawberry flavoured food quality control.

    PubMed

    Schipilliti, Luisa; Dugo, Paola; Bonaccorsi, Ivana; Mondello, Luigi

    2011-10-21

    Authenticity assessment of flavoured strawberry foods was performed using headspace-solid phase microextraction (HS-SPME) coupled to gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS). An authenticity range was achieved, investigating on the carbon isotope ratio of numerous selected aroma active volatile components (methyl butanoate, ethyl butanoate, hex-(2E)-enal, methyl hexanoate, buthyl butanoate, ethyl hexanoate, hexyl acetate, linalool, hexyl butanoate, octyl isovalerate, γ-decalactone and octyl hexanoate) of organic Italian fresh strawberries. To the author's knowledge, this is the first time that all these components were investigated simultaneously by GC-C-IRMS on the same sample. The results were compared, when applicable, with those obtained by analyzing the HS-SPME extracts of commercial flavoured food matrices. In addition, one Kenyan pineapple and one fresh Italian peach were analyzed to determine the δ(13)C(VPDB) of the volatile components common to strawberry. The δ(13)C(VPDB) values are allowed to differentiate between different biogenetic pathways (C(3) and CAM plants) and more interestingly between plants of the same CO(2) fixation group (C(3) plants). Additional analyses were performed on all the samples by means of Enantioselective Gas Chromatography (Es-GC), measuring the enantiomeric distribution of linalool and γ-decalactone. It was found that GC-C-IRMS and Es-GC measurements were in agreement to detect the presence of non-natural strawberry aromas in the food matrices studied.

  6. Identification of volatiles from pineapple (Ananas comosus L.) pulp by comprehensive two-dimensional gas chromatography and gas chromatography/mass spectrometry.

    PubMed

    Pedroso, Marcio P; Ferreira, Ernesto C; Hantao, Leandro W; Bogusz, Stanislau; Augusto, Fabio

    2011-07-01

    Combining qualitative data from the chromatographic structure of 2-D gas chromatography with flame ionization detection (GC×GC-FID) and that from gas chromatography-mass spectrometry (GC/MS) should result in a more accurate assignment of the peak identities than the simple analysis by GC/MS, where coelution of analytes is unavoidable in highly complex samples (rendering spectra unsuitable for qualitative purposes) or for compounds in very low concentrations. Using data from GC×GC-FID combined with GC/MS can reveal coelutions that were not detected by mass spectra deconvolution software. In addition, some compounds can be identified according to the structure of the GC×GC-FID chromatogram. In this article, the volatile fractions of fresh and dehydrated pineapple pulp were evaluated. The extraction of the volatiles was performed by dynamic headspace extraction coupled to solid-phase microextraction (DHS-SPME), a technique appropriate for slurries or solid matrices. Extracted analytes were then analyzed by GC×GC-FID and GC/MS. The results obtained using both techniques were combined to improve compound identifications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Off-odor compounds produced in cork by isolated bacteria and fungi: a gas chromatography-mass spectrometry and gas chromatography-olfactometry study.

    PubMed

    Prat, Chantal; Trias, Rosalia; Culleré, Laura; Escudero, Ana; Anticó, Enriqueta; Bañeras, Lluís

    2009-08-26

    The risk of development of specific olfactory profiles in cork was evaluated after inoculation of cork granules and agglomerated and natural cork stoppers with isolated bacteria and fungi. The highest incidence of off-odor development was found in assays when fungi were inoculated. Cork granules with musty-earthy, musty-earthy-TCA, and vegetative deviations were inspected by gas chromatography-olfactometry (GC-O) and gas chromatography-mass spectrometry (GC-MS). Sixteen odor zones were clearly recognized in the GC-O analyses. Among these, octanal, 2-methoxy-3,5-dimethylpyrazine (MDMP), Z-2-nonenal, 2-methylisoborneol, 2,4,6-trichloroanisole (TCA), geosmin, and guaiacol were the most significant odorants and helped in the discrimination of sensory deviations. Only TCA and guaiacol were detected above their respective detection limits by HS-SPME-GC-MS. The fungi Cryptococcus sp. isolate F020, Rhodotorula sp. isolate F025, Penicillium glabrum isolate F001, and Pennicillium variabile F003A and the bacterium Pseudomonas jessenii isolate A1 were found to produce TCA to a greater extent. Additionally, 13 of 38 isolated microorganisms (2 bacteria and 11 fungi) proved able to produce unpleasant musty-earthy or vegetative odors that were not related to a significant TCA accumulation.

  8. Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

    NASA Technical Reports Server (NTRS)

    Freeman, K. H.; Ricci, S. A.; Studley, A.; Hayes, J. M.

    1989-01-01

    On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values.

  9. Determination of oxalate in black liquor by headspace gas chromatography.

    PubMed

    Li, Hailong; Chai, Xin-Sheng; DeMartini, Nikolai; Zhan, Huaiyu; Fu, Shiyu

    2008-05-30

    This study demonstrated a headspace gas chromatographic method (HS-GC) for the determination of oxalate content in black liquor (alkaline aqueous solution of inorganic chemicals and dissolved wood species from the alkaline pulping of wood). The method described in this paper is based on the reaction between oxalic and manganese dioxide in an acidic medium, in which oxalic acid is converted to carbon dioxide that is measured with a GC using a thermal conductivity detector. The challenge in developing this method was ensuring complete conversion of oxalic acid while minimizing the contribution of side reactions between carbohydrates, lignin and manganese dioxide to the carbon dioxide measured. It was found that a complete conversion of oxalate to carbon dioxide can be achieved within 3 min at a temperature of 70 degrees C; a MnO(2):C(oxalate) (concentration of H(2)C(2)O(4)+HC(2)O(4)(-)+C(2)O(4)(2-)) mole ratio of 60 and H(2)SO(4) concentration of 0.005-0.01 mol/L in the headspace vial. The method can detect concentrations as low as 0.39 microg of oxalate. The standard deviation was found to be 7% while recovery experiments with black liquor showed recoveries of 93-108% which were deemed acceptable for analysis of oxalate in an industrial sample such as black liquor.

  10. Detection and identification of bacteria by gas chromatography.

    PubMed

    Henis, Y; Gould, J R; Alexander, M

    1966-07-01

    Ether extracts of cultures of 29 strains representing 6 species of Bacillus, and of individual strains of Escherichia coli, Aerobacter aerogenes, and Pseudomonas aeruginosa were examined in a gas chromatograph by use of flame ionization and electron capture detectors. Among the products detected were compounds with the chromatographic characteristics of acetic, propionic, and butyric acids, ethyl alcohol, diacetyl, acetoin, and 2,3-butanediol. The differences in peak areas of the various products formed by the bacteria were determined statistically for the chromatograms obtained with the two detectors, and the peaks were arranged in order of decreasing areas to yield a signature for each bacterial strain. Different signatures were obtained for the various genera and species and for strains of the same species. B. licheniformis, B. subtilis, and A. aerogenes formed significant quantities of a number of volatile compounds, and qualitative and quantitative differences between strains were noted. The electron capture detector was particularly sensitive to diacetyl and acetoin as well as to unknown compounds. By use of this detector, the presence of 5 pg of diacetyl and 20 pg of acetoin could be demonstrated. The quantity of acetoin detected in B. subtilis and B. licheniformis cultures was present in as little as 6.3 x 10(-3) muliters of medium.

  11. Dynamic headspace gas chromatography of volatile compounds in milk.

    PubMed

    Urbach, G

    1987-08-28

    A method is described for investigating volatile compounds in milk. The volatiles are removed from milk by a stream of helium swept at 100 ml/min over the surface of the milk at 70 degrees C. They are trapped on 40 mg of NIOSH charcoal and then desorbed by heat and re-trapped on the front of a chromatographic column of Tenax-GC coated with 1% OV-275, the column being maintained at room temperature during trapping. An amount of 40 mg NIOSH charcoal under these conditions traps over 90% of the total quantity of the lowest boiling compounds swept from the milk, such as acetaldehyde and ethanol, and retains 100% of the total quantity of acetone, propanol and higher boiling compounds from the gas stream. The volume of milk and its temperature affect the ratios of volatiles collected and these factors are useful in increasing the proportion of a volatile of particular interest. The addition of potassium carbonate increases the yield of volatiles from 100 ml aqueous phase but not from 10 ml.

  12. Utilizing a constant peak width transform for isothermal gas chromatography.

    PubMed

    Nadeau, Jeremy S; Wilson, Ryan B; Fitz, Brian D; Reed, Jason T; Synovec, Robert E

    2011-06-10

    A computational approach to partially address the general elution problem (GEP), and better visualize, isothermal gas chromatograms is reported. The theoretical computational approach is developed and applied experimentally. We report a high speed temporally increasing boxcar summation (TIBS) transform that, when applied to the raw isothermal GC data, converts the chromatographic data from the initial time domain (in which the peak widths in isothermal GC increase as a function of their retention factors, k), to a data point based domain in which all peaks have the same peak width in terms of number of points in the final data vector, which aides in preprocessing and data analysis, while minimizing data storage size. By applying the TIBS transform, the resulting GC chromatogram (initially collected isothermally), appears with an x-axis point scale as if it were instrumentally collected using a suitable temperature program. A high speed GC isothermal separation with a test mixture containing 10 compounds had a run time of ∼25 s. The peak at a retention factor k ∼0.7 had a peak width of ∼55 ms, while the last eluting peak at k ∼89 (i.e., retention time of ∼22 s) had a peak width of ∼2000 ms. Application of the TIBS transform increased the peak height of the last eluting peak 45-fold, and S/N ∼20-fold. All peaks in the transformed test mixture chromatogram had the width of an unretained peak, in terms of number of data points. A simulated chromatogram at unit resolution, studied using the TIBS transform, provided additional insight into the benefits of the algorithm.

  13. Differentiation of mint (Mentha haplocalyx Briq.) from different regions in China using gas and liquid chromatography.

    PubMed

    Dong, Wenjiang; Ni, Yongnian; Kokot, Serge

    2015-02-01

    In this study, complex substances such as Mint (Mentha haplocalyx Briq.) samples from different growing regions in China were analyzed for phenolic compounds by high-performance liquid chromatography with diode array detection and for the volatile aroma compounds by gas chromatography with mass spectrometry. Chemometrics methods, e.g. principal component analysis, back-propagation artificial neural networks, and partial least squares discriminant analysis, were applied to resolve complex chromatographic profiles of Mint samples. A total of 49 aroma components and 23 phenolic compounds were identified in 79 Mint samples. Principal component analysis score plots from gas chromatography with mass spectrometry and high-performance liquid chromatography with diode array detection data sets showed a clear distinction among Mint from three different regions in China. Classification results showed that satisfactory performance of prediction ability for back-propagation artificial neural networks and partial least squares discriminant analysis. The major compounds that contributed to the discrimination were chlorogenic acid, unknown 3, kaempherol 7-O-rutinoside, salvianolic acid L, hesperidin, diosmetin, unknown 6 and pebrellin in Mint according to regression coefficients of the partial least squares discriminant analysis model. This study indicated that the proposed strategy could provide a simple and rapid technique to distinguish clearly complex profiles from samples such as Mint. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. [Determination of 2-methyl-3-nitrobenzoic acid through pretreatment with diazomethane by gas chromatography].

    PubMed

    Xue, Ke-She; Nan, Zhi-Xiang

    2002-09-01

    A method for the quantitative determination of 2-methyl-3-nitrobenzoic acid by gas chromatography is described. 2-Methyl-3-nitrobenzoic acid was esterified by pretreatment with diazomethane prior to analysis. A CP-Sil-43CB capillary column(25 m x 0.32 mm i.d. x 0.2 microm), a flame ionization detector and the area normalization method were used. The average recovery was 99.81%. The RSD was 0.08% and the detection limit was 3 x 10(-11) g. The results showed that the method is practical and reliable. It was realized that the higher purity and higher boiler matter was analyzed by gas chromatography. The method can be used to monitor the purity of this type of materials. analysis of research and production. It can be used in the development of new products and in the process.

  15. Pyrolysis gas-liquid chromatography of the genus Bacillus: effect of growth media on pyrochromatogram reproducibility.

    PubMed

    Oxborrow, G S; Fields, N D; Puleo, J R

    1977-04-01

    Pyrolysis gas-liquid chromatography was performed on dried Bacillus microorganisms to evaluate the effects of growth media. Six cultures of Bacillus and six lot numbers of Trypticase soy agar (BBL) were used to test the hypothesis that a microorganism grown on various lot numbers of the same chromatogram. Also tested was the effect of three different media on chromatogram reproduction using the same six cultures. Results show little or no differences observed between the chromatograms of the individual Bacillus spp. grown on the six lot numbers of Trypticase soy agar. When chromatograms of the three different media were compared, several differences were observed, particularly in the areas most characteristic of individual species. Pryolysis gas-liquid chromatography can be a useful tool for the characterization or identification of the genus Bacillus if the chromatographic and cultural conditions are maintained.

  16. Investigating Solvent Purity Utilizing Comprehensive Gas Chromatography: A Study of Acetones

    SciTech Connect

    Wahl, Jon H.; Bolz, Cinnamon DH; Wahl, Karen L.

    2010-04-01

    Broad spectrum chemical analysis of trace level components is a continuing challenge for any analytical chemist. This challenge is further confounded when chemical impurities may be present in common organic solvents or when chemical artifacts may be formed, produced and introduced during an analytical procedure. Minimizing and understanding these chemical artifacts, is critical for trace level detection and is crucial for unambiguous analytical results. Comprehensive gas chromatography is an excellent analytical tool to help address these complex mixture challenges. This work examines the impurities present in various acetone sources utilizing comprehensive gas chromatography. This work highlights the extreme variability possible in solvent sources and hence the importance of understanding the impurities that may confound an analytical method or result.

  17. Measuring fuel contamination using high speed gas chromatography and cone penetration techniques

    SciTech Connect

    Farrington, S.P.; Bratton, W.L.; Akard, M.L.

    1995-10-01

    Decision processes during characterization and cleanup of hazardous waste sites are greatly retarded by the turnaround time and expense incurred through the use of conventional sampling and laboratory analyses. Furthermore, conventional soil and groundwater sampling procedures present many opportunities for loss of volatile organic compounds (VOC) by exposing sample media to the atmosphere during transfers between and among sampling devices and containers. While on-site analysis by conventional gas chromatography can reduce analytical turnaround time, time-consuming sample preparation procedures are still often required, and the potential for loss of VOC is not reduced. This report describes the development of a high speed gas chromatography and cone penetration testing system which can detect and measure subsurface fuel contamination in situ during the cone penetration process.

  18. Structural analysis of commercial ceramides by gas chromatography-mass spectrometry.

    PubMed

    Bleton, J; Gaudin, K; Chaminade, P; Goursaud, S; Baillet, A; Tchapla, A

    2001-05-11

    A simple method using gas chromatography-mass spectrometry was applied to analyse structures of ceramides. Identification of trimethylsilylated ceramides were obtained in short analysis times (derivatization of ceramides in 30 min at room temperature and 20 min gas chromatography mass spectrometry run) even for complex mixtures. For example in ceramide Type III, 18 peaks were observed which represent 27 various structures. The coeluted compounds were ceramides containing the same functional groups and the same carbon number but with a different distribution on the two alkyl chains of the molecule. They were accurately differentiated by mass spectrometry. Therefore, 83 structures of trimethylsilylated ceramides were identified in 11 different commercial mixtures. For 52 structures of these, mass spectral data were not described in the literature, neither full mass spectra nor characteristic fragments.

  19. Sputtered alumina as a novel stationary phase for micro machined gas chromatography columns.

    PubMed

    Haudebourg, R; Matouk, Z; Zoghlami, E; Azzouz, I; Danaie, K; Sassiat, P; Thiebaut, D; Vial, J

    2014-02-01

    Silica and graphite sputtering have previously been reported as novel solid stationary phase deposition techniques for micro gas chromatography columns. As a conventional solid stationary phase in gas chromatography, compatible with sputtering yet so far unreported, alumina was evaluated in this study. Alumina sputtered semi-packed micro columns were fabricated (including an activation step) and proved able to separate a mixture of volatile alkanes (C1-C4 with isomers) in less than 1 min. Kinetic and a thermodynamic evaluation led to calculation of 4,500 theoretical plates for ethane in 1.1 m (HETPmin = 250 μm) and a Gibbs free energy for propane of 30.2 kJ mol(-1), making this stationary phase's properties very close to those observed with silica-sputtered micro columns.

  20. Gas-liquid chromatography in routine processing of blood cultures for detecting anaerobic bacteraemia.

    PubMed Central

    Reig, M; Molina, D; Loza, E; Ledesma, M A; Meseguer, M A

    1981-01-01

    Gas-liquid chromatography was performed on 233 positive blood cultures and findings were compared with culture results. Obligate anaerobic bacteria were recovered from 78 out of 79 blood cultures containing butyric or iso-valeric acids, or both; from 28 out of 69 blood cultures containing succinic acid; and from only one out of 41 blood cultures containing succinic but not butyric or iso-valeric acid. Good correlations (88%) were found for the recovery of anaerobic bacteria and the detection of butyric and/or iso-valeric acids. Detecting volatile fatty acids by gas-liquid chromatography performed on blood cultures at the first signs of growth can therefore provide an early and reliable indication of the presence of anaerobic bacteria. PMID:7014645

  1. [Recent advances in analysis of petroleum geological samples by comprehensive two-dimensional gas chromatography].

    PubMed

    Gao, Xuanbo; Chang, Zhenyang; Dai, Wei; Tong, Ting; Zhang, Wanfeng; He, Sheng; Zhu, Shukui

    2014-10-01

    Abundant geochemical information can be acquired by analyzing the chemical compositions of petroleum geological samples. The information obtained from the analysis provides scientifical evidences for petroleum exploration. However, these samples are complicated and can be easily influenced by physical (e. g. evaporation, emulsification, natural dispersion, dissolution and sorption), chemical (photodegradation) and biological (mainly microbial degradation) weathering processes. Therefore, it is very difficult to analyze the petroleum geological samples and they cannot be effectively separated by traditional gas chromatography/mass spectrometry. A newly developed separation technique, comprehensive two-dimensional gas chromatography (GC x GC), has unique advantages in complex sample analysis, and recently it has been applied to petroleum geological samples. This article mainly reviews the research progres- ses in the last five years, the main problems and the future research about GC x GC applied in the area of petroleum geology.

  2. [Determination of nitenpyram residue in cabbage and soil using gas chromatography].

    PubMed

    Zhang, Guiqun; Nie, Siqiao; Long, Liping; Zeng, Dongqiang; Chen, Jiuxing; Yang, Hui; Chen, Linglong

    2010-11-01

    An analytical method for the determination of nitenpyram residue in cabbage and soil using gas chromatography was established. The nitenpyram residue was extracted from cabbage and soil with acetone-water (4 : 1, v/v), cleaned up by a Florisil column, and then detected by gas chromatography-electron capture detection (GC-ECD). At the spiked level range from 0.02 to 2.00 mg/kg, the average recoveries of nitenpyram were 88.73%-94.3% and 90.82%-96.27% with the relative standard deviations (RSDs) of 3.09%-7.39% and 2.01%-4.92% in cabbage and soil, respectively. The limit of detection of nitenpyram was 0.02 mg/kg. The method is fast, sensitive, simple, reproducible and practical for the determination of nitenpyram residue in environmental systems.

  3. Surface energy of microcrystalline cellulose determined by capillary intrusion and inverse gas chromatography.

    PubMed

    Steele, D Fraser; Moreton, R Christian; Staniforth, John N; Young, Paul M; Tobyn, Michael J; Edge, Stephen

    2008-09-01

    Surface energy data for samples of microcrystalline cellulose have been obtained using two techniques: capillary intrusion and inverse gas chromatography. Ten microcrystalline cellulose materials, studied using capillary intrusion, showed significant differences in the measured surface energetics (in terms of total surface energy and the acid-base characteristics of the cellulose surface), with variations noted between the seven different manufacturers who produced the microcrystalline cellulose samples. The surface energy data from capillary intrusion was similar to data obtained using inverse gas chromatography with the column maintained at 44% relative humidity for the three samples of microcrystalline cellulose studied. This suggests that capillary intrusion may be a suitable method to study the surface energy of pharmaceutical samples.

  4. Sample introduction in gas chromatography using a coiled wire filament.

    PubMed

    Truong, Tai V; Nackos, Aaron N; Murray, Jacolin A; Kimball, Jon A; Hawkes, Jason E; Harvey, Donald J; Tolley, H Dennis; Robison, Richard A; Bartholomew, Calvin H; Lee, Milton L

    2009-10-02

    A simple device for field sampling and concentration of analytes for subsequent introduction into an injection port for gas chromatographic (GC) analysis has been developed. It consists of a tiny, coiled platinum wire filament (CWF) that is attached to a retractable plunger wire, which fits inside a syringe needle housing. Sampling is accomplished by dipping the end of the CWF in a liquid sample, which is drawn into the wire coil by capillary action, and introducing it into the injection port either before or after allowing the solvent to evaporate. The CWF can be used with or without a nonvolatile chemical coating. A major advantage of this sampling device is that nonvolatile sample matrix components remain on the wire coil, reducing the required injection port and liner cleaning frequency and contamination of the head of the chromatographic column. The coil itself can be easily cleaned between analyses by rinsing and/or burning off residual material in a small flame. The sampling coil facilitates specifically designed chemical reactions in the injection port, such as thermochemolysis and methylation. Applications demonstrated in this work include: (1) direct introduction of samples with little or no pre-treatment, (2) simultaneous thermochemolysis and methylation of lipid-containing samples such as bacteria and bacterial endospores for analysis of biomarkers, and (3) solid phase micro-extraction (SPME) using temporary wire coatings. The CWF allowed for significant reduction in sample preparation time, in most cases to less than a few minutes. The peak shapes examined for polycyclic aromatic hydrocarbon analytes (PAHs) were significantly better (asymmetry factors <1.3) when using the CWF sampling technique compared to splitless and on-column injection techniques (asymmetry factors >1.3). Extraction efficiencies for SPME (especially for high boiling point components such as PAHs) improved by an average of 2.5 times when using the CWF compared to the performance of

  5. Determination of hydrazine metabolites of isoniazid in human urine by gas chromatography.

    PubMed

    Timbrell, J A; Wright, J M; Smith, C M

    1977-08-01

    A method is described for the determination of isoniazid, acetylisoniazid, acetylhydrazine, diacetylhydrazine and hydrazine in urine. Isoniazid, acetylhydrazine and hydrazine are reacted in aqueous solution with p-chlorobenzaldehyde to form hydrazones. Following the addition of appropriate internal standards, these hydrazones are then extracted into an organic solvent and determined by gas chromatography using a nitrogen-sensitive detector. Acetylisoniazid and diacetylhydrazine are determined similarly after hydrolysis to isoniazid and acetylhydrazine, respectively.

  6. Investigation of the composition of coking naphthalene impurities by gas-liquid chromatography

    SciTech Connect

    Nabivach, V.M.; Gerasimenko, V.A.; Ryabozad, A.S.; Voitenko, B.I.; Grumberg, L.R.; Chernyshov, Y.A.; Shvarts, S.G.

    1982-01-01

    An investigation of the impurities present in marketable naphthalene was presented. The concentrations of the impurities were determined by gas-liquid chromatography. Three different types of naphthalene fractions were tested--fusion, pressed, and centrifuged. It was determined that the total concentration of impurities reached 0.20-0.25 wt.%. Also, the pressed and fusion naphthalenes contained benzonitrile, dimethylnaphthalenes, diphenyl, acenaphthene, and diphenyleneoxide, which were not present in the centrifuged naphthalene.

  7. Sub-to super-ambient temperature programmable microfabricated gas chromatography column

    DOEpatents

    Robinson, Alex L.; Anderson, Lawrence F.

    2004-03-16

    A sub- to super-ambient temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by combining a thermoelectric cooler and temperature sensing on the microfabricated column. Sub-ambient temperature programming enables the efficient separation of volatile organic compounds and super-ambient temperature programming enables the elution of less volatile analytes within a reasonable time. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  8. Analysis of benzo(a)pyrene in airborne particulates by gas chromatography

    NASA Technical Reports Server (NTRS)

    Luedecke, E.

    1976-01-01

    A routine method was developed to measure benzo(a)pyrene in airborne particulates. Samples were collected on a filter and the organic portion was extracted with cyclohexane. The polynuclear hydrocarbon (PNHC) fraction was separated from the aliphatics by column chromatography. An internal standard was added to the extract and a portion of it was injected into a gas chromatograph. Although the gas chromatographic method has often been reported in the literature, satisfactory separation of benzo(a)pyrene and benzo(e)pyrene has not been achieved. With the introduction of a nematic liquid crystal as the stationary phase good separation is now possible.

  9. Study of Ether-, Alcohol-, or Cyano-Functionalized Ionic Liquids Using Inverse Gas Chromatography

    SciTech Connect

    Revelli, Anne-Laure; Mutelet, Fabrice; Jaubert, Jean-Noel; Garcia-Martinez, Marina; Sprunger, Laura; Acree, William; Baker, Gary A

    2010-01-01

    Activity coefficients of 52 organic compounds in four ionic liquids (ILs), 1,3-dimethoxyimidazolium bis((trifluoromethyl)sulfonyl)imide, 1-(methylethylether)-3-methylimidazolium bis((trifluoromethyl)sulfonyl) imide, 1-ethanol-3-methylimidazolium bis((trifluoromethyl)-sulfonyl)imide, and 1-(3-cyanopropyl)-3- methylimidazolium dicyanamide, were measured using inverse gas chromatography from (312 to 353) K. The retention data were also converted in gas-to-IL partition coefficients and water-to-IL partition coefficients using the corresponding gas-to-water partition coefficients. Both sets of partition coefficients were analyzed using the modified Abraham solvation parameter model. The derived equations correlated the experimental gas-to-IL and water-to-IL partition coefficient data to within (0.09 and 0.14) log units, respectively.

  10. Capillary gas chromatography coupled with microplasma mass spectrometry for organotin speciation.

    PubMed

    Brede, C; Pedersen-Bjergaard, S; Lundanes, E; Greibrokk, T

    1999-07-23

    Gas chromatography was coupled with microplasma mass spectrometry for selective detection of organotin compounds. The microplasma ion source was a capacitively coupled radiofrequency helium plasma, which was located inside the high vacuum area of the mass spectrometer. Only 1-3 ml min-1 of helium carrier gas from the gas chromatograph was necessary for sustaining the plasma while 0.15-1.5 ml min-1 of hydrogen was added as reagent gas. Hydrogen was applied for prevention of carbon deposition and served to minimize the interactions between tin and the fused-silica inner surface of the microplasma ion source. Both carbon and tin were detected as positively charged atomic ions, which were expelled from the microplasma ion source and directly focused by electrostatic lenses towards the quadrupole mass analyzer. Tin exhibited high selectivity to carbon (> 10(4)) and a detection limit of 3.5 pg s-1.

  11. Surface energy of bovine dentin and enamel by means of inverse gas chromatography.

    PubMed

    Okulus, Zuzanna; Strzemiecka, Beata; Czarnecka, Beata; Buchwald, Tomasz; Voelkel, Adam

    2015-04-01

    Adhesion between tooth tissues and dental fillings depends on the surface energy of both connected materials. Bond strength can be determined directly or indirectly as a work of adhesion on the basis of values of surface energy of these materials. Inverse gas chromatography (IGC) is one of the methods of surface energy examination. In this study the values of total surface energy components of wet and dry teeth fragments (enamel, crown dentin and root dentin) were determined with the use of inverse gas chromatography. Inverse gas chromatography has never been used for investigation of surface energy of natural tooth tissues. Different storage conditions were examined - wet and dry. Different values of surface energy are observed according to the type of tooth tissue (dentin or enamel), occurring place (crown or root) and storage conditions (dry or wet). The effect of tissue type and occurring place was the greatest, while storage conditions were of secondary importance. Surface energy depends on composition of tissue, its surface area and the presence of pores. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Quantification of carbonate by gas chromatography-mass spectrometry.

    PubMed

    Tsikas, Dimitrios; Chobanyan-Jürgens, Kristine

    2010-10-01

    Carbon dioxide and carbonates are widely distributed in nature, are constituents of inorganic and organic matter, and are essential in vegetable and animal organisms. CO(2) is the principal greenhouse gas in the atmosphere. In human blood, CO(2)/HCO(3)(-) is an important buffering system. Quantification of bicarbonate and carbonate in inorganic and organic matter and in biological fluids such as blood or blood plasma by means of the GC-MS technology has been impossible so far, presumably because of the lack of suitable derivatization reactions to produce volatile and thermally stable derivatives. Here, a novel derivatization reaction is described for carbonate that allows for its quantification in aqueous alkaline solutions and alkalinized plasma and urine. Carbonate in acetonic solutions of these matrices (1:4 v/v) and added (13)C-labeled carbonate for use as the internal standard were heated in the presence of the derivatization agent pentafluorobenzyl (PFB) bromide for 60 min and 50 °C. Investigations with (12)CO(3)(2-), (13)CO(3)(2-), (CH(3))(2)CO, and (CD(3))(2)CO in alkaline solutions and GC-MS and GC-MS/MS analyses under negative-ion chemical ionization (NICI) or electron ionization (EI) conditions of toluene extracts of the reactants revealed formation of two minor [i.e., PFB-OCOOH and O=CO(2)-(PFB)(2)] and two major [i.e., CH(3)COCH(2)-C(OH)(OPFB)(2) and CH(3)COCH=C(OPFB)(2)] carbonate derivatives. The latter have different retention times (7.9 and 7.5 min, respectively) but virtually identical EI and NICI mass spectra. It is assumed that CH(3)COCH(2)-C(OH)(OPFB)(2) is formed from the reaction of the carbonate dianion with two molecules of PFB bromide to form the diPFB ester of carbonic acid, which further reacts with one molecule of acetone. Subsequent loss of water finally generates the major derivative CH(3)COCH=C(OPFB)(2). This derivatization reaction was utilized to quantify total CO(2)/HCO(3)(-)/CO(3)(2-) (tCO(2)) in human plasma and urine by GC

  13. Use of greatly-reduced gas flows in flow-modulated comprehensive two-dimensional gas chromatography-mass spectrometry.

    PubMed

    Tranchida, Peter Q; Franchina, Flavio A; Dugo, Paola; Mondello, Luigi

    2014-09-12

    The present research is specifically based on the use of greatly-reduced gas flows, in flow-modulator (FM) comprehensive two-dimensional gas chromatography systems. In particular, focus of the present research is directed to FM devices characterized by an accumulation stage, and a much briefer re-injection step. It has been widely accepted that the operation of such FM systems requires high gas flows (≥20mL/min), to re-inject the gas-phase contents of sample (or accumulation) loops, onto the second column. On the contrary, it will be herein demonstrated that much lower gas flows (≈ 6-8mL/min) can efficiently perform the modulation step of re-injection. The possibility of using such improved operational conditions is given simply by a fine optimization of the processes of accumulation and re-injection. The application of lower gas flows not only means that second-dimension separations are carried out under better analytical conditions, but, even more importantly, greatly reduces problems which arise when using mass spectrometry (i.e., sensitivity and instrumental pumping capacity).

  14. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    PubMed

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Methods for analysis of conjugated linoleic acids and trans-18:1 isomers in dairy fats by using a combination of gas chromatography, silver-ion thin-layer chromatography/gas chromatography, and silver-ion liquid chromatography.

    PubMed

    Cruz-Hernandez, Cristina; Deng, Zeyuan; Zhou, Jianqiang; Hill, Arthur R; Yurawecz, Martin P; Delmonte, Pierluigi; Mossoba, Magdi M; Dugan, Michael E R; Kramer, John K G

    2004-01-01

    Conjugated linoleic acids (CLA) are octadecadienoic acids (18:2) that have a conjugated double-bond system. Interest in these compounds has expanded since CLA were found to be associated with a number of physiological and pathological responses such as cancer, metastases, atherosclerosis, diabetes, immunity, and body fat/protein composition. The main sources of these conjugated fatty acids are dairy fats. Rumen bacteria convert polyunsaturated fatty acids, especially linoleic and linolenic acids, to CLA and numerous trans- containing mono- and diunsaturated fatty acids. It has been established that an additional route of CLA synthesis in ruminants and monogastric animals, including humans, occurs via delta9 desaturation of the trans-18:1 isomers. To date, a total of 6 positional CLA isomers have been found in dairy fats, each occurring in 4 geometric forms (cis,trans; trans,cis; cis,cis; and trans,trans) for a total of 24. All of these CLA isomers can be resolved only by a combination of gas chromatography (GC), using 100 m highly polar capillary columns, and silver-ion liquid chromatography, using 3 of these 25 cm columns in series. Complete analysis of all the trans-18:1 isomers requires prior isolation of trans monoenes by silver-ion thin-layer chromatography (TLC), followed by GC analysis using the same 100 m capillary columns operated at low temperatures starting from 120 degrees C. These analytical techniques are required to assess the purity of commercial CLA preparations, because their purity will affect the interpretation of any physiological and/or biochemical response obtained. Prior assessment of CLA preparations by TLC is also recommended to determine the presence of any other impurities. The availability of pure CLA isomers will permit the evaluation and analysis of individual CLA isomers for their nutritional and biological activity in model systems, animals, and humans. These techniques are also essential to evaluate dairy fats for their content of

  16. Application of gas chromatography-cryocondensation-Fourier transform infrared spectroscopy and gas chromatography-mass spectrometry to the identification of gas phase reaction products from the alpha-pinene/ozone reaction.

    PubMed

    Schrader, W; Geiger, J; Hoffmann, T; Klockow, D; Korte, E H

    1999-12-24

    The gas phase reaction of alpha-pinene with the atmospheric oxidant ozone was investigated by using the capabilities of both gas chromatography-cryocondensation-Fourier transform infrared spectroscopy (GC-FT-IR) and gas chromatography-mass spectrometry (GC-MS), for the identification of the reaction products formed. The reaction was carried out in a flow reaction chamber from where the compounds were sampled on Tenax-containing adsorption cartridges. The reaction mixture was injected onto the column after thermodesorption and analyzed using both GC-IR and GC-MS. Twenty compounds could be detected, including the reactant alpha-pinene and it's impurities tricyclene and camphene. Eleven compounds were identified by spectra comparison with either reference data or spectra obtained from commercial standards. Four compounds were tentatively identified from their IR and MS spectra, while from the remaining two compounds the nature of basic functional groups could be established.

  17. Multiresidue analysis of pesticides in traditional Chinese medicines using gas chromatography - negative chemical ionization tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    In this study, a residue analysis method for the simultaneous determination of 107 pesticides in the traditional Chinese medicines (TCMs), Angelica sinensis, Angelica dahurica, Leonurus heterophyllus Sweet, Pogostemon cablin, and Lonicera japonica Thunb, was developed using gas chromatography couple...

  18. Simultaneous Determination of Cyanide and Thiocyanate in Plasma by Chemical Ionization Gas Chromatography Mass-Spectrometry (CI-GC-MS)

    DTIC Science & Technology

    2012-09-04

    ORIGINAL PAPER Simultaneous determination of cyanide and thiocyanate in plasma by chemical ionization gas chromatography mass-spectrometry (CI-GC-MS...chemical ioniza- tion gas chromatography-mass spectrometry was developed for the simultaneous determination of cyanide and thiocya- nate in plasma...Sample preparation for this analysis required essentially one-step by combining the reaction of cyanide and thiocyanate with pentafluorobenzyl bromide

  19. Isolation and identification of the metolachlor stereoisomers using high-performance liquid chromatography, polarimetric measurements, and enantioselective gas chromatography.

    PubMed

    Müller, M D; Poiger, T; Buser, H

    2001-01-01

    Because of the presence of two chiral elements (an asymmetrically substituted carbon and a chiral axis), the herbicide metolachlor consists of four stereoisomers stable at ambient temperature with aSS-, aRS-, aSR-, and aRR-configurations (aSS, the isomer with aS,1'S-configuration, etc.). Metolachlor, initially introduced into the market as the racemic product containing all four stereoisomers, is currently being replaced worldwide by S-metolachlor, the product enantiomerically enriched with the herbicidally active 1'S-isomers (aSS, aRS). The isomer-specific analysis of metolachlor requires not only enantioselective ("chiral") analytical techniques but also suitable reference compounds. In this study, two of the four metolachlor isomers were isolated from rac-metolachlor in enantio- (ee > 98%) and diastereomerically pure forms by a combination of achiral and chiral high-performance liquid chromatography (HPLC). The two isomers were identified as the aSS- and the aRR-isomers by polarimetric measurements, in reference to previous data. The two isomers were then thermally equilibrated to 1:1 mixtures of the aSS/aRS and aRR/aSR diastereomers, respectively, so that analytical data of all four metolachlor isomers became available; they were then used to identify these isomers in technical products by chiral high-resolution gas chromatography (HRGC). The kinetics of the thermally induced interconversion of the atropisomers was studied and the consequences, such as for GC analysis, are discussed. A comparison of on-column and split/splitless injection indicated that the latter technique results in significant isomerization prior to separation and, therefore, cannot be used for accurate isomer analysis.

  20. Arabidopsis thaliana Polar Glycerolipid Profiling by Thin Layer Chromatography (TLC) Coupled with Gas-Liquid Chromatography (GLC)

    PubMed Central

    Wang, Zhen; Benning, Christoph

    2011-01-01

    Biological membranes separate cells from the environment. From a single cell to multicellular plants and animals, glycerolipids, such as phosphatidylcholine or phosphatidylethanolamine, form bilayer membranes which act as both boundaries and interfaces for chemical exchange between cells and their surroundings. Unlike animals, plant cells have a special organelle for photosynthesis, the chloroplast. The intricate membrane system of the chloroplast contains unique glycerolipids, namely glycolipids lacking phosphorus: monogalactosyldiacylglycerol (MGDG), digalactosyldiacylglycerol (DGDG), sulfoquinovosyldiacylglycerol (SQDG)4. The roles of these lipids are beyond simply structural. These glycolipids and other glycerolipids were found in the crystal structures of photosystem I and II indicating the involvement of glycerolipids in photosynthesis8,11. During phosphate starvation, DGDG is transferred to extraplastidic membranes to compensate the loss of phospholipids9,12. Much of our knowledge of the biosynthesis and function of these lipids has been derived from a combination of genetic and biochemical studies with Arabidopsis thaliana14. During these studies, a simple procedure for the analysis of polar lipids has been essential for the screening and analysis of lipid mutants and will be outlined in detail. A leaf lipid extract is first separated by thin layer chromatography (TLC) and glycerolipids are stained reversibly with iodine vapor. The individual lipids are scraped from the TLC plate and converted to fatty acyl methylesters (FAMEs), which are analyzed by gas-liquid chromatography coupled with flame ionization detection (FID-GLC) (Figure 1). This method has been proven to be a reliable tool for mutant screening. For example, the tgd1,2,3,4 endoplasmic reticulum-to-plastid lipid trafficking mutants were discovered based on the accumulation of an abnormal galactoglycerolipid: trigalactosyldiacylglycerol (TGDG) and a decrease in the relative amount of 18:3 (carbons

  1. Determination of ink photoinitiators in packaged beverages by gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry.

    PubMed

    Sagratini, Gianni; Caprioli, Giovanni; Cristalli, Gloria; Giardiná, Dario; Ricciutelli, Massimo; Volpini, Rosaria; Zuo, Yanting; Vittori, Sauro

    2008-06-20

    A new analytical method, using gas chromatography-mass spectrometry (GC/MS) and liquid chromatography-mass spectrometry (LC/MS) techniques, was developed for the determination in packaged food beverages of five ink photoinitiator residues: 2-isopropylthioxanthone (ITX), benzophenone, 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB), 1-hydroxycyclohexyl-1-phenyl ketone (IRGACURE 184) and ethyl-4-dimethylaminobenzoate (EDAB). Samples were extracted from selected beverages (milk, fruit juices and wine) and relative packagings, using n-hexane and dichloromethane, respectively, purified on solid-phase extraction (SPE) silica gel cartridges, and then analyzed in GC/MS and LC/MS. The recovery percentages, obtained spiking the beverage samples at concentrations of 4 and 10 microgl(-1) with a standard mixture of photoinitiators, were in the range 42-108% (milk), 50-84% (wine), and 48-109% (fruit juices). The repeatability of the method was assessed in all cases by the % of correlation value, that was lower than 19%. The lowest limits of detection (LODs) and limits of quantification (LOQs), obtained using GC/MS, were in the range 0.2-1 and 1-5 microgl(-1), respectively. The method was applied to the analysis of forty packaged food beverages (milk, fruit juices and wine samples). The most significant contamination was that of benzophenone, found in all samples in a concentration range of 5-217mugl(-1). Its presence was confirmed by an LC/Atmospheric-Pressure PhotoIonization (APPI)/MS/MS analysis. The photoinitiator (EHDAB) was found in eleven out of forty beverages in a concentration range of 0.13-0.8 microgl(-1). Less important was the ITX contamination, found in three out of forty samples in a range 0.2-0.24 microgl(-1). The work proposes a new method to analyze ink photoinitiator residues in polycoupled carton packaging and in contained food beverages.

  2. Determination of alkyl amines in atmospheric aerosol particles: a comparison of gas chromatography-mass spectrometry and ion chromatography approaches

    NASA Astrophysics Data System (ADS)

    Huang, R.-J.; Li, W.-B.; Wang, Y.-R.; Wang, Q. Y.; Ho, K.-F.; Cao, J. J.; Wang, G. H.; Chen, X.; Haddad, I. EI; Zhuang, Z. X.; Wang, X. R.; Prévôt, A. S. H.; O'Dowd, C. D.; Hoffmann, T.

    2014-03-01

    In recent years low molecular weight alkyl amines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkyl amines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography-mass spectrometry (GC-MS) and ion chromatography (IC), for the determination of alkyl amines in aerosol particles. Alkyl amines were converted to carbamates through derivatization with isobutyl chloroformate for GC-MS determination. A set of parameters affecting the analytical performances of the GC-MS approach, including reagent amount, reaction time and pH value, was evaluated and optimized. The accuracy is 84.3-99.1%, and the limits of detection obtained are 1.8-3.9 pg. For the IC approach, a solid phase extraction (SPE) column was used to separate alkyl amines from interfering cations before IC analysis. 1-2% (v/v) of acetone (or 2-4% (v/v) of acetonitrile) was added to the eluent to improve the separation of alkyl amines on the IC column. The limits of detection obtained are 2.1-15.9 ng and the accuracy is 55.1-103.4%. The lower accuracy can be attributed to evaporation losses of amines during the sample concentration procedure. Measurements of ambient aerosol particle samples collected in Hong Kong show that the GC-MS approach is superior to the IC approach for the quantification of primary and secondary alkyl amines due to its lower detection limits and higher accuracy.

  3. Determination of alkylamines in atmospheric aerosol particles: a comparison of gas chromatography-mass spectrometry and ion chromatography approaches

    NASA Astrophysics Data System (ADS)

    Huang, R.-J.; Li, W.-B.; Wang, Y.-R.; Wang, Q. Y.; Jia, W. T.; Ho, K.-F.; Cao, J. J.; Wang, G. H.; Chen, X.; Haddad, I. EI; Zhuang, Z. X.; Wang, X. R.; Prévôt, A. S. H.; O'Dowd, C. D.; Hoffmann, T.

    2014-07-01

    In recent years low molecular weight alkylamines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkylamines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography-mass spectrometry (GC-MS) and ion chromatography (IC), for the determination of alkylamines in aerosol particles. Alkylamines were converted to carbamates through derivatization with isobutyl chloroformate for GC-MS determination. A set of parameters affecting the analytical performances of the GC-MS approach, including reagent amount, reaction time and pH value, was evaluated and optimized. The accuracy is 84.3-99.1%, and the limits of detection obtained are 1.8-3.9 pg (or 0.02-0.04 ng m-3). For the IC approach, a solid-phase extraction (SPE) column was used to separate alkylamines from interfering cations before IC analysis. 1-2% (v/v) of acetone (or 2-4% (v/v) of acetonitrile) was added to the eluent to improve the separation of alkylamines on the IC column. The limits of detection obtained are 2.1-15.9 ng (or 0.9-6.4 ng m-3), and the accuracy is 55.1-103.4%. The lower accuracy can be attributed to evaporation losses of amines during the sample concentration procedure. Measurements of ambient aerosol particle samples collected in Hong Kong show that the GC-MS approach is superior to the IC approach for the quantification of primary and secondary alkylamines due to its lower detection limits and higher accuracy.

  4. Continuous determination of volatile products in anaerobic fermenters by on-line capillary gas chromatography.

    PubMed

    Diamantis, V; Melidis, P; Aivasidis, A

    2006-07-28

    Bio-ethanol and biogas produced during the anaerobic conversion of organic compounds has been a subject of great interest since the oil crisis of the 1970s. In ethanol fermentation and anaerobic treatment of wastewaters, end-product (ethanol) and intermediate-products (short-chain fatty acids, SCFA) cause inhibition that results in reduced process efficiency. Control of these constituents is of utmost importance for bioreactor optimization and process stability. Ethanol and SCFA can be detected with precision by capillary gas chromatography usually conducted in off-line measurements. In this work, an on-line monitoring and controlling system was developed and connected to the fermenter via an auto-sampling equipment, which could perform the feeding, filtration and dilution of the sample and final injection into the gas chromatograph through an automation-based programmed procedure. The sample was continuously pumped from the recycle stream of the bioreactor and treated using a microfiltration unit. The concentrate was returned to the reactor while the permeate was quantitatively mixed with an internal standard solution. The system comprised of a gas chromatograph with the flow cell and one-shot sampler and a PC with the appropriate software. The on-line measurement of ethanol and SCFA, directly from the liquid phase of an ethanol fermenter and a high-rate continuous mode anaerobic digester, was accomplished by gas chromatography. Also, this monitoring and controlling system was proved to be effective in the continuous fermentation of alcohol-free beer.

  5. Identification and measurement of chlorinated organic pesticides in water by electron-capture gas chromatography

    USGS Publications Warehouse

    Lamar, William L.; Goerlitz, Donald F.; Law, LeRoy M.

    1965-01-01

    Pesticides, in minute quantities, may affect the regimen of streams, and because they may concentrate in sediments, aquatic organisms, and edible aquatic foods, their detection and their measurement in the parts-per-trillion range are considered essential. In 1964 the U.S. Geological Survey at Menlo Park, Calif., began research on methods for monitoring pesticides in water. Two systems were selected--electron-capture gas chromatography and microcoulometric-titration gas chromatography. Studies on these systems are now in progress. This report provides current information on the development and application of an electron-capture gas chromatographic procedure. This method is a convenient and extremely sensitive procedure for the detection and measurement of organic pesticides having high electron affinities, notably the chlorinated organic pesticides. The electron-affinity detector is extremely sensitive to these substances but it is not as sensitive to many other compounds. By this method, the chlorinated organic pesticide may be determined on a sample of convenient size in concentrations as low as the parts-per-trillion range. To insure greater accuracy in the identifications, the pesticides reported were separated and identified by their retention times on two different types of gas chromatographic columns.

  6. Separation and Detection of Toxic Gases with a Silicon Micromachined Gas Chromatography System

    NASA Technical Reports Server (NTRS)

    Kolesar, Edward S.; Reston, Rocky R.

    1995-01-01

    A miniature gas chromatography (GC) system was designed and fabricated using silicon micromachining and integrated circuit (IC) processing techniques. The silicon micromachined gas chromatography system (SMGCS) is composed of a miniature sample injector that incorporates a 10 microliter sample loop; a 0.9 meter long, rectangular shaped (300 micrometer width and 10 micrometer height) capillary column coated with a 0.2 micrometer thick copper phthalocyanine (CuPc) stationary phase; and a dual detector scheme based upon a CuPc-coated chemiresistor and a commercially available 125 micrometer diameter thermal conductivity detector (TCD) bead. Silicon micromachining was employed to fabricate the interface between the sample injector and the GC column, the column itself, and the dual detector cavity. A novel IC thin-film processing technique was developed to sublime the CuPc stationary phase coating on the column walls that were micromachined in the host silicon wafer substrate and Pyrex (r) cover plate, which were then electrostatically bonded together. The SMGCS can separate binary gas mixtures composed of parts-per-million (ppm) concentrations of ammonia (NH3) and nitrogen dioxide (NO2) when isothermally operated (55-80 degrees C). With a helium carrier gas and nitrogen diluent, a 10 microliter sample volume containing ammonia and nitrogen dioxide injected at 40 psi ((2.8 x 10(exp 5)Pa)) can be separated in less than 30 minutes.

  7. Multidimensional gas chromatography for the detailed PIONA analysis of heavy naphtha: hyphenation of an olefin trap to comprehensive two-dimensional gas chromatography.

    PubMed

    Vendeuvre, Colombe; Bertoncini, Fabrice; Espinat, Didier; Thiébaut, Didier; Hennion, Marie-Claire

    2005-10-07

    A multidimensional method providing the composition of a heavy naphtha in paraffins, isoparaffins, olefins, naphthenes, and aromatics (PIONA) in the C8-C14 range is presented. The analytical set-up consists in a silver modified silica olefin trap on-line coupled to comprehensive two-dimensional gas chromatography (GC x GC). In this configuration, hydrocarbons are separated, in gaseous state, in two fractions, saturate and unsaturate, each fraction being subsequently analysed by GC or by GC x GC. The resolution between saturates and olefins was found to be improved compared to a single GC x GC run. The characterisation of the olefin trap highlights the benefits and the limits related to the use of that stationary phase as a double bond selective fractionation medium.

  8. Gas Phase Chromatography of some Group 4, 5, and 6 Halides

    SciTech Connect

    Sylwester, Eric Robert

    1998-10-01

    Gas phase chromatography using The Heavy Element Volatility Instrument (HEVI) and the On Line Gas Apparatus (OLGA III) was used to determine volatilities of ZrBr4, HfBr4, RfBr4, NbBr5, TaOBr3, HaCl5, WBr6, FrBr, and BiBr3. Short-lived isotopes of Zr, Hf, Rf, Nb, Ta, Ha, W, and Bi were produced via compound nucleus reactions at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory and transported to the experimental apparatus using a He gas transport system. The isotopes were halogenated, separated from the other reaction products, and their volatilities determined by isothermal gas phase chromatography. Adsorption Enthalpy (ΔHa) values for these compounds were calculated using a Monte Carlo simulation program modeling the gas phase chromatography column. All bromides showed lower volatility than molecules of similar molecular structures formed as chlorides, but followed similar trends by central element. Tantalum was observed to form the oxybromide, analogous to the formation of the oxychloride under the same conditions. For the group 4 elements, the following order in volatility and ΔHa was observed: RfBr4 > ZrBr4 > HfBr4. The ΔHa values determined for the group 4, 5, and 6 halides are in general agreement with other experimental data and theoretical predictions. Preliminary experiments were performed on Me-bromides. A new measurement of the half-life of 261Rf was performed. 261Rf was produced via the 248Cm(18O, 5n) reaction and observed with a half-life of 74-6+7 seconds, in excellent agreement with the previous measurement of 78-6+11 seconds. We recommend a new half-life of 75±7 seconds for 261Rf based on these two measurements. Preliminary studies in transforming HEVI from an isothermal (constant

  9. Impurity analysis of 1,4-dioxane in nonionic surfactants and cosmetics using headspace solid-phase microextraction coupled with gas chromatography and gas chromatography-mass spectrometry.

    PubMed

    Fuh, C Bor; Lai, M; Tsai, H Y; Chang, C M

    2005-04-15

    1,4-Dioxane impurity in nonionic surfactants and cosmetics were analyzed using solid-phase microextraction (SPME) coupled with gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). Experimental results show that there is no significant difference using SPME-GC and SPME-GC-MS for analysis of 1,4-dioxane in three types of nonionic surfactants at the 95% confidence level. The relative standard deviation (R.S.D.) values of each analytical method were smaller than 3%. The amount of 1,4-dioxane was found to vary from 11.6 +/- 0.3 ppm to 73.5 +/- 0.5 ppm in 30% of nonionic surfactants from manufacturers in Taiwan. These methods were linear over the studied range of 3-150 ppm with correlation coefficients higher than 0.995. The recoveries of 1,4-dioxane for these nonionic surfactants following SPME were all higher than 96 +/- 1% (n = 3). The detection limits of 1,4-dioxane for these nonionic surfactants following SPME were from 0.06 ppm to 0.51 ppm. The experimentally determined level of 1,4-dioxane in cosmetics from manufacturers in Taiwan varied from 4.2 +/- 0.1 ppm to 41.1 +/- 0.6 ppm in 22% of daily used cosmetics following SPME coupled with GC and GC-MS. Conventional solvent extraction takes around 1 h for extraction and reconcentration but SPME takes only around 10 min. SPME provides better analyses of 1,4-dioxane in nonionic surfactants and cosmetics than conventional solvent extraction and head space pretreatments in term of simplicity, speed, precision, detection limit, and solvent consumption.

  10. The characterization of eight maceral concentrates by means of Curie point pyrolysis-gas chromatography and Curie point pyrolysis-gas chromatography-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Nip, Margriet; De Leeuw, J. W.; Schenck, P. A.

    1988-03-01

    In order to study the relationships between the chemical structures of coals, coal macerals and their precursors (plant tissues), eight coal macerals originating from the Yorkshire coal basin (U.K.) were studied by Curie point pyrolysis-gas chromatography and Curie point pyrolysis-gas chromatography-mass spectrometry. The samples were selected on the basis of a previous study of a large set of macerals. The macerals were studied in order to relate structural moieties of the macerals, as reflected by their pyrolysis products, to structural elements of their likely precursors, plant tissues. The maceral pyrolysates mainly consist of alkylbenzenes, alkylnaphthalenes, alkylphenols and series of straight-chain alk-l-enes and alkanes over a wide molecular weight range. The relative contribution of the (hydroxy)aromatic pyrolysis products and of the straight-chain alk-l-enes and alkanes to each maceral pyrolysate was calculated, although the internal distribution patterns of the alkyl derivatives of these pyrolysis products exhibited to a certain extent dissimilarities. Differences between the relative contributions of these pyrolysis products to the pyrolysates of different macerals with the same coal rank and to those of similar macerals with different coal rank depend on differences in precursor material and the chemical modification of these precursors upon increasing coalification. Multivariate data treatment by means of factor analysis was chosen to compare the pyrolysis data - represented by these histograms - with the petrographic data and the proximate and ultimate analysis values of the macerals. In addition, similar analyses was performed on the macerals using such a low Curie temperature (358°C), that from some of the macerals "thermal extracts" were obtained, containing a series of n-alkanes and some isoprenoids such as pristane and phytane. Although these thermal extracts represent only a low percentage by weight of the maceral samples, their existence

  11. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples.

    PubMed

    Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath

    2010-09-01

    Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations.

  12. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples

    PubMed Central

    Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath

    2010-01-01

    Background: Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. Materials and Methods: We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. Results: AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Conclusions: Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations. PMID:22558586

  13. Metabolomics by Gas Chromatography-Mass Spectrometry: the combination of targeted and untargeted profiling

    PubMed Central

    Fiehn, Oliver

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS)-based metabolomics is ideal for identifying and quantitating small molecular metabolites (<650 daltons), including small acids, alcohols, hydroxyl acids, amino acids, sugars, fatty acids, sterols, catecholamines, drugs, and toxins, often using chemical derivatization to make these compounds volatile enough for gas chromatography. This unit shows that on GC-MS- based metabolomics easily allows integrating targeted assays for absolute quantification of specific metabolites with untargeted metabolomics to discover novel compounds. Complemented by database annotations using large spectral libraries and validated, standardized standard operating procedures, GC-MS can identify and semi-quantify over 200 compounds per study in human body fluids (e.g., plasma, urine or stool) samples. Deconvolution software enables detection of more than 300 additional unidentified signals that can be annotated through accurate mass instruments with appropriate data processing workflows, similar to liquid chromatography-MS untargeted profiling (LC-MS). Hence, GC-MS is a mature technology that not only uses classic detectors (‘quadrupole’) but also target mass spectrometers (‘triple quadrupole’) and accurate mass instruments (‘quadrupole-time of flight’). This unit covers the following aspects of GC-MS-based metabolomics: (i) sample preparation from mammalian samples, (ii) acquisition of data, (iii) quality control, and (iv) data processing. PMID:27038389

  14. Metabolomic Strategies Involving Mass Spectrometry Combined with Liquid and Gas Chromatography.

    PubMed

    Lopes, Aline Soriano; Cruz, Elisa Castañeda Santa; Sussulini, Alessandra; Klassen, Aline

    2017-01-01

    Amongst all omics sciences, there is no doubt that metabolomics is undergoing the most important growth in the last decade. The advances in analytical techniques and data analysis tools are the main factors that make possible the development and establishment of metabolomics as a significant research field in systems biology. As metabolomic analysis demands high sensitivity for detecting metabolites present in low concentrations in biological samples, high-resolution power for identifying the metabolites and wide dynamic range to detect metabolites with variable concentrations in complex matrices, mass spectrometry is being the most extensively used analytical technique for fulfilling these requirements. Mass spectrometry alone can be used in a metabolomic analysis; however, some issues such as ion suppression may difficultate the quantification/identification of metabolites with lower concentrations or some metabolite classes that do not ionise as well as others. The best choice is coupling separation techniques, such as gas or liquid chromatography, to mass spectrometry, in order to improve the sensitivity and resolution power of the analysis, besides obtaining extra information (retention time) that facilitates the identification of the metabolites, especially when considering untargeted metabolomic strategies. In this chapter, the main aspects of mass spectrometry (MS), liquid chromatography (LC) and gas chromatography (GC) are discussed, and recent clinical applications of LC-MS and GC-MS are also presented.

  15. Fast and accurate numerical method for predicting gas chromatography retention time.

    PubMed

    Claumann, Carlos Alberto; Wüst Zibetti, André; Bolzan, Ariovaldo; Machado, Ricardo A F; Pinto, Leonel Teixeira

    2015-08-07

    Predictive modeling for gas chromatography compound retention depends on the retention factor (ki) and on the flow of the mobile phase. Thus, different approaches for determining an analyte ki in column chromatography have been developed. The main one is based on the thermodynamic properties of the component and on the characteristics of the stationary phase. These models can be used to estimate the parameters and to optimize the programming of temperatures, in gas chromatography, for the separation of compounds. Different authors have proposed the use of numerical methods for solving these models, but these methods demand greater computational time. Hence, a new method for solving the predictive modeling of analyte retention time is presented. This algorithm is an alternative to traditional methods because it transforms its attainments into root determination problems within defined intervals. The proposed approach allows for tr calculation, with accuracy determined by the user of the methods, and significant reductions in computational time; it can also be used to evaluate the performance of other prediction methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Metabolomics by Gas Chromatography-Mass Spectrometry: Combined Targeted and Untargeted Profiling.

    PubMed

    Fiehn, Oliver

    2016-04-01

    Gas chromatography-mass spectrometry (GC-MS)-based metabolomics is ideal for identifying and quantitating small-molecule metabolites (<650 Da), including small acids, alcohols, hydroxyl acids, amino acids, sugars, fatty acids, sterols, catecholamines, drugs, and toxins, often using chemical derivatization to make these compounds sufficiently volatile for gas chromatography. This unit shows how GC-MS-based metabolomics allows integration of targeted assays for absolute quantification of specific metabolites with untargeted metabolomics to discover novel compounds. Complemented by database annotations using large spectral libraries and validated standard operating procedures, GC-MS can identify and semiquantify over 200 compounds from human body fluids (e.g., plasma, urine, or stool) per study. Deconvolution software enables detection of more than 300 additional unidentified signals that can be annotated through accurate mass instruments with appropriate data processing workflows, similar to untargeted profiling using liquid chromatography-mass spectrometry. GC-MS is a mature technology that uses not only classic detectors (quadrupole) but also target mass spectrometers (triple quadrupole) and accurate mass instruments (quadrupole-time of flight). This unit covers sample preparation from mammalian samples, data acquisition, quality control, and data processing. Copyright © 2016 John Wiley & Sons, Inc.

  17. Quantitative determination of formaldehyde in cosmetics using combined headspace-solid-phase microextraction-gas chromatography.

    PubMed

    Rivero, Rene Thomas; Topiwala, Vinod

    2004-01-01

    The objective of this research was the application of headspace (HS)-solid-phase microextraction (SPME) for the quantitation of formaldehyde present in raw materials and cosmetic formulations. The formaldehyde was derivatized in situ first with pentafluorophenylhydrazine (PFPH), to form a derivative hydrazone. The formed hydrozone was adsorbed on a SPME fiber during headspace extraction under controlled conditions (time, temperature, volume, etc.). After the adsorption step, the SPME fiber was directly transferred into the gas chromatography (GC) injection port in which the analytes were thermally desorbed. Deuterated acetone was used as an internal standard (IS) in order to quantitate the formaldehyde content. For the experiment, a gas chromatograph equipped with a flame ionization detector (GC/FID) was employed. A gas chromatograph/mass spectrometer (GC/MS) was used for the qualitative confirmation of results in this work.

  18. Complete elution of vacuum gas oil resins by comprehensive high-temperature two-dimensional gas chromatography.

    PubMed

    Boursier, Laure; Souchon, Vincent; Dartiguelongue, Cyril; Ponthus, Jérémie; Courtiade, Marion; Thiébaut, Didier

    2013-03-08

    The development of efficient conversion processes requires extended knowledge on vacuum gas oils (VGOs). Among these processes, hydrocracking is certainly one of the best suited to meet the increasing demand on high quality diesel fuels. Most of refractory and inhibiting compounds towards hydrocracking and especially nitrogen containing compounds are contained in a fraction of the VGO called the resin fraction, which corresponds to the most polar fraction of a VGO obtained by liquid chromatography (LC) fractionation on a silica column. However, the lack of resolution observed through existing analytical methods does not allow a detailed characterization of these fractions. A recent study showed that comprehensive high temperature two-dimensional gas chromatography (HT-GC×GC) methods could be optimized in order to elute heavy compounds. This method was implemented for the analysis of VGO resin fractions and complete elution was reached. Firstly, the method was validated through repeatability, accuracy, linearity and response factors calculations. Four VGO resin fractions were analyzed and their HT-GC×GC simulated distillation curves were compared to their GC simulated distillation (GC-SimDist) curves. This comparison showed that the method allows complete elution of most of the analyzed VGO resin fractions. However, a detailed characterization of these fractions is not yet obtained due to the very large number of heteroatomic and aromatic species that a flame ionization detector can detect. Current work aims at increasing the selectivity of GC×GC by using heteroatom selective detectors in order to improve the characterization of such products.

  19. Detection of ergot (Claviceps purpurea) in a dairy feed component by gas chromatography and mass spectrometry.

    PubMed

    Mantle, P G

    1996-11-01

    A dairy feed that contained barley malt screenings caused hyperthermia in dairy cattle. The feed was suspected of containing ergot and was subsequently analyzed to determine the ricinoleate component, a special and prominent feature of oil-rich ergot tissue. Triglyceride oil was extracted by organic solvents from the dairy feed, and the oil was saponified to release fatty acids. Ricinoleate, as a methyl ester, was selectively resolved from other fatty acids by silica gel chromatography and was analyzed by capillary gas chromatography coupled with chemical ionization mass spectrometry, which demonstrated the presence of the methyl ricinoleate molecule and proved that the feed contained ergot. The methodology may be refined to monitor for ergot in powdered dairy feed more routinely.

  20. Global urinary metabolic profiling procedures using gas chromatography-mass spectrometry.

    PubMed

    Chan, Eric Chun Yong; Pasikanti, Kishore Kumar; Nicholson, Jeremy K

    2011-09-08

    The role of urinary metabolic profiling in systems biology research is expanding. This is because of the use of this technology for clinical diagnostic and mechanistic studies and for the development of new personalized health care and molecular epidemiology (population) studies. The methodologies commonly used for metabolic profiling are NMR spectroscopy, liquid chromatography mass spectrometry (LC/MS) and gas chromatography-mass spectrometry (GC/MS). In this protocol, we describe urine collection and storage, GC/MS and data preprocessing methods, chemometric data analysis and urinary marker metabolite identification. Results obtained using GC/MS are complementary to NMR and LC/MS. Sample preparation for GC/MS analysis involves the depletion of urea via treatment with urease, protein precipitation with methanol, and trimethylsilyl derivatization. The protocol described here facilitates the metabolic profiling of ∼400-600 metabolites in 120 urine samples per week.

  1. High-pressure liquid chromatography with direct injection of gas sample.

    PubMed

    Astanin, Anton I; Baram, Grigory I

    2017-06-09

    The conventional method of using liquid chromatography to determine the composition of a gaseous mixture entails dissolving vapors in a suitable solvent, then obtaining a chromatograph of the resulting solution. We studied the direct introduction of a gaseous sample into a C18 reversed-phase column, followed by separation of the components by HPLC with UV detection. Since the chromatography was performed at high pressure, vapors readily dissolved in the eluent and the substances separated in the column as effectively as in liquid samples. Samples were injected into the column in two ways: a) through the valve without a flow stop; b) after stopping the flow and relieving all pressure. We showed that an injectable gas volume could reach 70% of column dead volume. When an injected gaseous sample volume was less than 10% of the column dead volume, the resulting peaks were symmetrical and the column efficiency was high. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Amperometric detector for gas chromatography based on a silica sol-gel solid electrolyte.

    PubMed

    Steinecker, William H; Miecznikowski, Krzysztof; Kulesza, Pawel J; Sandlin, Zechariah D; Cox, James A

    2017-11-01

    An electrochemical cell comprising a silica sol-gel solid electrolyte, a working electrode that protrudes into a gas phase, and reference and counter electrodes that contact the solid electrolyte comprises an amperometric detector for gas chromatography. Under potentiostatic conditions, a current related to the concentration of an analyte in the gas phase is produced by its oxidation at the three-phase boundary among the sol-gel, working electrode, and the gas phase. The sol-gel is processed to contain an electrolyte that also serves as a humidistat to maintain a constant water activity even in the presence the gas chromatographic mobile phase. Response was demonstrated toward a diverse set of analytes, namely hydrogen, 1,2-ethandithiol, phenol, p-cresol, and thioanisole. Using flow injection amperometry of hydrogen with He as the carrier gas, 90% of the steady-state current was achieved in < 1s at a flow rate of 20mLmin(-1). A separation of 1,2-ethandithiol, phenol, p-cresol, and thioanisole at a 2.2mLmin(-1) flow rate was achieved with respective detection limits (k = 3 criterion) of 4, 1, 3, and 70 ppmv when the working electrode potential was 800mV. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Characterization of odorant compounds of mussels (Mytilus edulis) according to their origin using gas chromatography-olfactometry and gas chromatography-mass spectrometry.

    PubMed

    Le Guen, S; Prost, C; Demaimay, M

    2000-10-27

    Gas chromatography-olfactometry consists of sniffing the effluent of a gas chromatograph and leads to the direct determination of potent odorants in food. GC-olfactometry and GC-MS were applied in order to identify volatile compounds, and to characterize potent odorants of cooked wild mussels and bouchot mussels. Eighty-five volatiles were identified by GC-MS, among those the majority were identified for the first time in mussels. Using GC-olfactometry, the main contributors of cooked mussels aroma were characterized. Of the 85 volatiles identified in the flavor, only 33 were odor-active and contribute to the overall aroma of mussels. Dimethyl disulfide (sulfury odor) was the odorant the most differently perceived between the two extracts and seems to be characteristic of wild mussels. Combined GC-MS and GC-olfactometry made it possible to point out odorants which actually contribute to the aroma of cooked mussels and those which showed typical dependence on the origin of mussels.

  4. Gas chromatography/mass spectrometry and pyrolysis-gas chromatography/mass spectrometry for the chemical characterisation of modern and archaeological figs (Ficus carica).

    PubMed

    Ribechini, Erika; Pérez-Arantegui, Josefina; Colombini, Maria Perla

    2011-06-24

    Gas chromatography/mass spectrometry (GC/MS) after alkaline hydrolysis, solvent extraction and trimethylsilylation, and analytical pyrolysis using hexamethyldisilazane (HMDS) for in situ derivatisation followed by gas chromatographic/mass spectrometric analysis (Pyrolysis-silylation-GC/MS) were used to investigate the hydrolysable and soluble constituents, and the polymerised macromolecules of an archaeological fig (Ficus carica) recovered in Zaragoza (Spain), as well as of modern figs. The main aim was to study the compositional alterations undergone by the fig tissues in a particular archaeological environment: the fig was in a vessel and covered by a layer of a mixture of orpiment and gypsum. A comparison between the GC/MS results from modern and archaeological figs revealed that degradative reactions took place, leading to the disappearance/depletion of reactive (unsaturated fatty acids) and sensitive compounds (phytosterols and triterpenes). Py-silylation-GC/MS data provided evidence of a significant degradation of the saccharide and lipid components of the fig tissue, which left a residue enriched in polyphenols and polyesters. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Measuring the relative concentration of H2 and D2 in HD gas with gas chromatography

    NASA Astrophysics Data System (ADS)

    Whisnant, C. Steven; Hansen, Patrick A.; Kelley, Travis D.

    2011-02-01

    Frozen-spin polarized hydrogen deuteride (HD) targets are being prepared for photonuclear experiments at Jefferson Lab. The targets are frozen HD gas. To polarize and achieve the required spin-lattice relaxation times, the targets are made from high purity HD gas in which the residual H2 and D2 concentrations are known. To determine these residual concentrations, a gas chromatograph is used. The separation of the gas components is done in a column cooled to ≈120 K by immersing it in a mixture of liquid nitrogen and isopentane and using neon as the carrier gas. The different hydrogen isotopes have different transit times through the column and their arrival is registered by a thermal conductivity detector. The peaks in the chromatograms are fit using an exponentially modified Gaussian line shape to extract the areas of these peaks. The ratios of areas are corrected for differences in thermal conductivity to give the relative concentrations. Here, H2 and D2 concentrations on the order of a few percent have been measured with uncertainties of less than ± 5%. The linear response of the system is confirmed to within about ± 6.3%.

  6. Gas chromatography-vacuum ultraviolet spectroscopy for analysis of fatty acid methyl esters.

    PubMed

    Fan, Hui; Smuts, Jonathan; Bai, Ling; Walsh, Phillip; Armstrong, Daniel W; Schug, Kevin A

    2016-03-01

    A new vacuum ultraviolet (VUV) detector for gas chromatography was recently developed and applied to fatty acid methyl ester (FAME) analysis. VUV detection features full spectral acquisition in a wavelength range of 115-240nm, where virtually all chemical species absorb. VUV absorption spectra of 37 FAMEs, including saturated, monounsaturated, and polyunsaturated types were recorded. Unsaturated FAMEs show significantly different gas phase absorption profiles than saturated ones, and these classes can be easily distinguished with the VUV detector. Another advantage includes differentiating cis/trans-isomeric FAMEs (e.g. oleic acid methyl ester and linoleic acid methyl ester isomers) and the ability to use VUV data analysis software for deconvolution of co-eluting signals. As a universal detector, VUV also provides high specificity, sensitivity, and a fast data acquisition rate, making it a powerful tool for fatty acid screening when combined with gas chromatography. The fatty acid profile of several food oil samples (olive, canola, vegetable, corn, sunflower and peanut oils) were analyzed in this study to demonstrate applicability to real world samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Feasibility of the preparation of silica monoliths for gas chromatography: fast separation of light hydrocarbons.

    PubMed

    Azzouz, Imadeddine; Essoussi, Anouar; Fleury, Joachim; Haudebourg, Raphael; Thiebaut, Didier; Vial, Jerome

    2015-02-27

    The preparation conditions of silica monoliths for gas chromatography were investigated. Silica-based monolithic capillary columns based on sol-gel process were tested in the course of high-speed gas chromatographic separations of light hydrocarbons mixture (C1-C4). The impact of modifying the amount of porogen and/or catalyst on the monolith properties were studied. At the best precursor/catalyst/porogen ratio evaluated, a column efficiency of about 6500 theoretical plates per meter was reached with a very good resolution (4.3) for very light compounds (C1-C2). The test mixture was baseline separated on a 70cm column. To our knowledge for the first time a silica-based monolithic capillary column was able to separate light hydrocarbons from methane to n-butane at room temperature with a back pressure in the range of gas chromatography facilities (under 4.1bar). Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Determination of vaporization enthalpies of the branched esters from correlation gas chromatography and transpiration methods

    SciTech Connect

    Verevkin, S.P.; Heintz, A.

    1999-12-01

    Vaporization enthalpies are indispensable for the assessment of the environmental fate and behavior of environmental contaminants. The temperature dependencies of retention indices of a set of 80 esters with branched molecular structures were measured on a nonpolar gas chromatographic column. The correlation gas chromatography method and reliable data set of 16 esters selected from the literature were used to derive a correlation for the prediction of the standard molar enthalpies of vaporization {Delta}{sub 1}{sup g}H{sub m}{sup {degree}} at the temperature T = 298.15 K. Experimental values of {Delta}{sub 1}{sup g}H{sub m}{sup {degree}} for 64 branched esters were obtained with the help of this correlation. The vaporization enthalpies of isopentyl acetate, ethyl hexanoate, and neopentyl pivalate were additionally obtained by the transpiration method from the temperature dependence of the vapor pressure measured in a flow system and used for checking the validity of the correlation gas chromatography method.

  9. [Determination of residual solvents in 7-amino-3-chloro cephalosporanic acid by gas chromatography].

    PubMed

    Ma, Li; Yao, Tong-wei

    2011-01-01

    To develop a gas chromatography method for determination of residual solvents in 7-amino-3-chloro cephalosporanic acid (7-ACCA). The residual levels of acetone, methanol, dichloromethane, ethyl acetate, isobutanol, pyridine and toluene in 7-ACCA were measured by gas chromatography using Agilent INNOWAX capillary column (30 m × 0.32 mm,0.5 μm). The initial column temperature was 70° maintained for 6 min and then raised (10°C/min) to 160°C for 1 min. Nitrogen gas was used as carrier and FID as detector. The flow of carrier was 1.0 ml/min, the temperature of injection port and detector was 200°C and 250°C, respectively. The limits of detection for acetone, methanol, dichloromethane, ethyl acetate, isobutanol, pyridine, toluene in 7-ACCA were 2.5 μg/ml, 1.5 μg/ml, 15 μg/ml, 2.5 μg/ml, 2.5 μg/ml, 2.5 μg/ml and 11 μg/ml, respectively. Only acetone was detected in the sample, and was less than the limits of Ch.P. The method can effectively detect the residual solvents in 7-ACCA.

  10. Multiple inert gas elimination technique by micropore membrane inlet mass spectrometry--a comparison with reference gas chromatography.

    PubMed

    Kretzschmar, Moritz; Schilling, Thomas; Vogt, Andreas; Rothen, Hans Ulrich; Borges, João Batista; Hachenberg, Thomas; Larsson, Anders; Baumgardner, James E; Hedenstierna, Göran

    2013-10-15

    The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.

  11. Gas chromatography/mass spectrometry analysis of exhaled leukotrienes in asthmatic patients

    PubMed Central

    Cap, P; Chladek, J; Pehal, F; Maly, M; Petru, V; Barnes, P; Montuschi, P

    2004-01-01

    Background: Leukotriene-like immunoreactivity has been detected in exhaled breath condensate (EBC), but definitive evidence for the presence of leukotrienes (LTs) in this biological fluid is not available. A study was undertaken to determine whether LTC4, LTD4, LTE4, and LTB4 are measurable in EBC by gas chromatography/mass spectrometry and to quantify exhaled LTs in adults and children with asthma and in control subjects. Methods: Twenty eight adults and 33 children with mild to moderate persistent asthma treated with inhaled corticosteroids and age matched healthy controls (50 adults and 50 children) were studied. LTB4, LTC4, LTD4, and LTE4 in EBC were measured by gas chromatography/mass spectrometry. Results: LTD4, LTE4, and LTB4 were detectable in all samples. Concentrations of LTC4 in EBC were either close to or below the detection limit of 1 pg/ml. Median exhaled LTD4, LTE4, and LTB4 concentrations in asthmatic adults were increased 4.1-fold (p<0.001), 1.8-fold (p<0.01), and 2.6-fold (p<0.001), respectively, compared with values in healthy adults. Median exhaled LTD4, LTE4, and LTB4 concentrations in asthmatic children were increased 2.8-fold (p<0.001), 1.3-fold (p<0.001), and 1.6-fold (p<0.001), respectively, compared with those in healthy children. In patients with asthma there was a correlation between exhaled LTD4 and LTE4 in both adults (r = 0.87, p<0.0001) and children (r = 0.78, p<0.0001). Conclusions: Gas chromatography/mass spectrometry can be used to accurately quantify exhaled LTs which are increased in asthmatic adults and children compared with controls. PMID:15170025

  12. Gas chromatography-vacuum ultraviolet detection for classification and speciation of polychlorinated biphenyls in industrial mixtures.

    PubMed

    Qiu, Changling; Cochran, Jack; Smuts, Jonathan; Walsh, Phillip; Schug, Kevin A

    2017-03-24

    Polychlorinated biphenyls (PCBs) are a group of synthetic chlorinated compounds that have been widely used as dielectric fluids in capacitors and transformers. Due to their toxicity, persistence, and bioaccumulation in the food chain, PCBs are an environmental concern and among the most analyzed compounds in environmental analysis. The most common analytical methods for analysis of PCBs are based on gas chromatography-electron capture detection (GC-ECD) and gas chromatography-mass spectrometry (GC-MS). However, the number of possible congeners (209), similarities of physical and chemical properties, and complexity of sample matrices make it difficult to distinguish and accurately speciate PCB congeners using existing methods. This study presents a new method using gas chromatography with vacuum ultraviolet detection (GC-VUV), which offers absorption detection in the range of 120-240nm, where all chemical species have absorption. The VUV absorption spectra for all 209 PCB congeners were collected and shown to be differentiable. The capability of VUV data analysis software for deconvolution of co-eluting signals was also demonstrated. An automated time interval deconvolution (TID) procedure was applied to rapidly speciate individual PCBs, as well as classify commercial Aroclor mixtures based on their degree of chlorination. The data showed excellent agreement between the stated nominal and determined degrees of chlorination (less than 1% deviation for highly chlorinated mixtures). GC-VUV was verified to provide excellent specificity, high sensitivity (100-150pg limit of detection), and fast data acquisition for this application. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Comprehensive two-dimensional gas chromatography applied to illicit drug analysis.

    PubMed

    Mitrevski, Blagoj; Wynne, Paul; Marriott, Philip J

    2011-11-01

    Multidimensional gas chromatography (MDGC), and especially its latest incarnation--comprehensive two-dimensional gas chromatography (GC × GC)--have proved advantageous over and above classic one-dimensional gas chromatography (1D GC) in many areas of analysis by offering improved peak capacity, often enhanced sensitivity and, especially in the case of GC × GC, the unique feature of 'structured' chromatograms. This article reviews recent advances in MDGC and GC × GC in drug analysis with special focus on ecstasy, heroin and cocaine profiling. Although 1D GC is still the method of choice for drug profiling in most laboratories because of its simplicity and instrument availability, GC × GC is a tempting proposition for this purpose because of its ability to generate a higher net information content. Effluent refocusing due to the modulation (compression) process, combined with the separation on two 'orthogonal' columns, results in more components being well resolved and therefore being analytically and statistically useful to the profile. The spread of the components in the two-dimensional plots is strongly dependent on the extent of retention 'orthogonality' (i.e. the extent to which the two phases possess different or independent retention mechanisms towards sample constituents) between the two columns. The benefits of 'information-driven' drug profiling, where more points of reference are usually required for sample differentiation, are discussed. In addition, several limitations in application of MDGC in drug profiling, including data acquisition rate, column temperature limit, column phase orthogonality and chiral separation, are considered and discussed. Although the review focuses on the articles published in the last decade, a brief chronological preview of the profiling methods used throughout the last three decades is given.

  14. Inverse gas chromatography. V - Computer simulation of diffusion processes on the column

    NASA Technical Reports Server (NTRS)

    Hattam, Paul; Munk, Petr

    1988-01-01

    The elution behavior of low molecular weight probes on inverse gas chromatography (IGC) columns is simulated using a computer. The IGC model is based on a polymer stationary phase of uniform thickness with a nonnegligible resitance to probe penetration. Three characteristic numbers are found to determine the whole process: Z(p) characterizing the distribution of the probe between phases, Z(f) describing the diffusion in the polymer phase, and Z(g) related to diffusion in the gaseous phase. For situations when Z(p)/Z(f) is less than 2, the standard evaluation procedures are virtually useless. The actual behavior of such systems is described.

  15. Screening of Brazilian fruit aromas using solid-phase microextraction-gas chromatography-mass spectrometry.

    PubMed

    Augusto, F; Valente, A L; dos Santos Tada, E; Rivellino, S R

    2000-03-17

    Manual headspace solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) was used for the qualitative analysis of the aromas of four native Brazilian fruits: cupuassu (Theobroma grandiflorum, Spreng.), cajá (Spondias lutea. L.), siriguela (Spondias purpurea, L.) and graviola (Anona reticulata, L). Industrialized pulps of these fruits were used as samples, and extractions with SPME fibers coated with polydimethylsiloxane, polyacrylate, Carbowax and Carboxen were carried out. The analytes identified included several alcohols, esters, carbonyl compounds and terpernoids. The highest amounts extracted, evaluated from the sum of peak areas, were achieved using the Carboxen fiber.

  16. Simple, specific analysis of organophosphorus and carbamate pesticides in sediments using column extraction and gas chromatography

    USGS Publications Warehouse

    Belisle, A.A.; Swineford, D.M.

    1988-01-01

    A simple, specific procedure was developed for the analysis of organophosphorus and carbamate pesticides in sediment. The wet soil was mixed with anhydrous sodium sulfate to bind water and the residues were column extracted in acetone:methylene chloride (1:l,v/v). Coextracted water was removed by additional sodium sulfate packed below the sample mixture. The eluate was concentrated and analyzed directly by capillary gas chromatography using phosphorus and nitrogen specific detectors. Recoveries averaged 93 % for sediments extracted shortly after spiking, but decreased significantly as the samples aged.

  17. Analysis of the citric acid cycle intermediates using gas chromatography-mass spectrometry.

    PubMed

    Kombu, Rajan S; Brunengraber, Henri; Puchowicz, Michelle A

    2011-01-01

    Researchers view analysis of the citric acid cycle (CAC) intermediates as a metabolomic approach to identifying unexpected correlations between apparently related and unrelated pathways of metabolism. Relationships of the CAC intermediates, as measured by their concentrations and relative ratios, offer useful information to understanding interrelationships between the CAC and metabolic pathways under various physiological and pathological conditions. This chapter presents a relatively simple method that is sensitive for simultaneously measuring concentrations of CAC intermediates (relative and absolute) and other related intermediates of energy metabolism using gas chromatography-mass spectrometry.

  18. [Gas chromatography in quantitative analysis of hydrocyanic acid and its salts in cadaveric blood].

    PubMed

    Iablochkin, V D

    2003-01-01

    A direct gas chromatography method was designed for the quantitative determination of cyanides (prussic acid) in cadaveric blood. Its sensitivity is 0.05 mg/ml. The routine volatile products, including substances, which emerge due to putrefaction of organic matters, do not affect the accuracy and reproducibility of the method; the exception is H-propanol that was used as the internal standard. The method was used in legal chemical expertise related with acute cyanide poisoning (suicide) as well as with poisoning of products of combustion of nonmetals (foam-rubber). The absolute error does not exceed 10% with a mean quadratic deviation of 0.0029-0.0033 mg.

  19. Investigation of the triacylglycerol composition of iceman's mummified tissue by high-temperature gas chromatography.

    PubMed

    Mayer, B X; Reiter, C; Bereuter, T L

    1997-04-25

    The pattern of intact triacylglycerols of a skin sample from the 5300-year-old Iceman mummy (nicknamed Otzi) was resolved on a diphenyl-dimethylpolysiloxane stationary phase by high-temperature gas chromatography. Adipocere from a 64-year-old glacier mummy as well as recent human subcutaneous fat served as a comparison in this study. Qualitatively, the results for mummy samples were similar with well-preserved saturated, but decomposed unsaturated, triacylglycerols, the latter being predominant in subcutaneous fat. Excellent preservation of triacylglycerols with odd carbon numbers and branched acyl chains was observed. The results presented here shed new light on the process of mummification.

  20. Analysis of the anthraquinones aloe-emodin and aloin by gas chromatography/mass spectrometry.

    PubMed

    ElSohly, Mahmoud A; Gul, Waseem; Murphy, Timothy P

    2004-12-20

    A procedure was developed for the determination of low levels of the anthraquinones aloe-emodin and aloin A (barbalin) in aloe products based on gas chromatography/mass spectrometry (GC/MS) of the trimethyl silyl (TMS) derivatives of these analytes in the presence of Chrysophanol used as internal standard. The method was used to analyze several aloe based commercial products (liquids, gels and solids). Wide variation in the level of these anthraquinones was observed among the different products. The method had a sensitivity of 0.005 ppm of aloe-emodin and 0.05 ppm of aloin.

  1. Gas chromatography/mass spectrometry characterization of historical varnishes of ancient Italian lutes and violin.

    PubMed

    Echard, J P; Benoit, C; Peris-Vicente, J; Malecki, V; Gimeno-Adelantado, J V; Vaiedelich, S

    2007-02-12

    The organic constituents of historical vanishes from two ancient Italian lutes and a Stradivari violin, kept in the Musée de la musique in Paris, have been characterized using gas chromatography-mass spectrometry. Results have been compared with the chromatograms and mass spectra of recent as well as old naturally aged reference materials. The three historical varnishes analyzed have been shown to be oil varnishes, probably mixtures of linseed oil with resins. Identification of diterpenoids and triterpenoids compounds, and of the resins that may have been ingredients of the varnishes, are discussed in this paper.

  2. Developments in the application of gas chromatography with atomic emission (plus mass spectrometric) detection.

    PubMed

    van Stee, L L P; Brinkman, U A Th

    2008-04-04

    Capillary gas chromatography with atomic emission detection is a highly element-selective and sensitive detection technique for many non-metal as well as metallic elements. A 3-5 order of magnitude element/carbon selectivity, compound-independent calibration and the possibility to calculate (partial) molecular formulae are some of the attractive features of the technique. In the present review, the emphasis is on real-life applications for non-metals such as sulphur, phosphorus, nitrogen and the halogens, and on the potential of combined atomic emission/mass spectrometric detection.

  3. Some unique properties of gas chromatography coupled with atomic-emission detection.

    PubMed

    Andersson, Jan T

    2002-07-01

    The atomic-emission detector in gas chromatography is enormously versatile in applications in analytical chemistry. Its unique properties of high selectivity for most elements and low limits of detection combine to make it the preferred detector for many analytical problems. In this review the stress is laid on the possibility of using it for compound-independent calibration, for determination of the empirical formula of an unknown analyte, for isotope-selective detection, and on derivatization to give AED-active derivatives with advantageous detection properties. Both metals and non-metals are considered and examples of the use of atomic emission detection in real-world analysis are discussed.

  4. Determination of Surface Energy of Natural Zeolite by Inverse Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Bilgiç, Ceyda; Karakehya, Naile

    2016-10-01

    In this study, surface energy of natural zeolite was investigated using inverse gas chromatography (IGC). Purified zeolite was prepared from natural zeolite applying decantation and centrifugation process together. For IGC studies, retention time of n-octane, n-nonane and n-decane were measured at infinite dilution conditions, between 250 and 280 °C. Dispersive component of the surface energy (γd S)of purified zeolite was calculated. γd S values calculated using Schultz et al methods decrease with temperature.

  5. Identification of cryptorchidism in horses by analysing urine samples with gas chromatography/mass spectrometry.

    PubMed

    Leung, David K K; Tang, Francis P W; Wan, Terence S M; Wong, Jenny K Y

    2011-01-01

    Currently there are two common radioimmunoassay-based methods for the detection of equine cryptorchidism; one measures testosterone concentrations in peripheral blood samples taken before and after an intravenous injection of human chorionic gonadotrophin (hCG) and the other measures plasma estrone sulfate. However, each of these invasive methods has its own shortfalls and neither gives unequivocal results. In this article a highly reliable gas chromatography/mass spectrometry (GC/MS) method is described based on the analysis of urine samples for the identification of cryptorchidism in horses, some as young as 2 years old. 2009 Elsevier Ltd. All rights reserved.

  6. Acid-base and surface energy characterization of grafted polyethylene using inverse gas chromatography.

    PubMed

    Uhlmann, Petra; Schneider, Steffen

    2002-09-06

    For a specific design of interfaces, i.e. in composites and blends, it is essential to know the surface thermodynamics of the components. Polyethylene grafted with maleic anhydride and maleic anhydride-styrene mixtures, respectively, was the component of interest of our investigations. Inverse gas chromatography (IGC) at infinite dilution was shown to be an appropriate method to evaluate the dispersive and acid-base surface characteristics although there is an influence of bulk absorption and morphology when performing IGC above the glass transition temperature of the polymer.

  7. [Quantitative determination of strychnine in blood and urine by gas chromatography with mass-selective detector].

    PubMed

    Kataev, S S; Krylova, E A

    2010-01-01

    A method for the quantitative determination of strychnine in biological fluids by gas chromatography--mass spectrometry is proposed. The preparation of samples for the analysis included extraction of strychnine from blood and urine with the use of AccuBond(II) EVIDEX cartridges for solid-phase extraction and SPEC MP3 disks respectively. The efficiency of extraction was estimated at 0.05 mg/l for blood and 0.02 mg/l for urine. The detection limit was 0.10 mg/l in blood and 0.05 mg/l in urine.

  8. Review of stationary phases for microelectromechanical systems in gas chromatography: feasibility and separations.

    PubMed

    Azzouz, I; Vial, J; Thiébaut, D; Haudebourg, R; Danaie, K; Sassiat, P; Breviere, J

    2014-02-01

    This review covers the recent development of stationary phases for chip-based gas chromatography (GC). Portable systems for rapid and reliable analysis are urgently needed. One way to achieve this is to miniaturize the entire analysis. Because the column is the central component of the GC system and determines the feasibility and quality of separation, this review focuses on stationary phases reported in the literature and their use in different fields during the last two decades, with emphasis on different methods for introducing the stationary phase into the GC column.

  9. Static headspace gas chromatography of (semi-)volatile drugs in pharmaceuticals for topical use.

    PubMed

    Sitaramaraju, Yarramraju; van Hul, Ariane; Wolfs, Kris; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin

    2008-08-05

    An analytical method that allows simultaneous analysis of some (semi-)volatile drugs and additives in pharmaceuticals for topical use was developed using classical static headspace as sampling technique combined with gas chromatography (HS-GC). The capillary column used, RSL-200, showed good selectivity towards all the analytes in the samples investigated. Among the different dilution media investigated, dimethyl sulfoxide in combination with sodium chloride solution showed better sensitivity. Using the optimized headspace sample dilution medium, better sensitivities for all the analytes were achieved at low thermostatting temperature (85 degrees C). The optimized HS-GC method with flame ionization detection showed good repeatability, linearity and accuracy.

  10. Analysis of volatile organic compounds in groundwater samples by gas chromatography-mass spectrometry

    SciTech Connect

    Bernhardt, J.

    1995-08-23

    The Savannah River Site contains approximately 1500 monitoring wells from which groundwater samples are collected. Many of these samples are sent off-site for various analyses, including the determination of trace volatile organic compounds (VOCs). This report describes accomplishments that have been made during the past year which will ultimately allow VOC analysis to be performed on-site using gas chromatography-mass spectrometry. Through the use of the on-site approach, it is expected that there will be a substantial cost savings. This approach will also provide split-sample analysis capability which can serve as a quality control measure for off-site analysis.

  11. Comparison of photoacoustic radiometry to gas chromatography/mass spectrometry methods for monitoring chlorinated hydrocarbons

    SciTech Connect

    Sollid, J.E.; Trujillo, V.L.; Limback, S.P.; Woloshun, K.A.

    1996-03-01

    A comparison of two methods of gas chromatography mass spectrometry (GCMS) and a nondispersive infrared technique, photoacoustic radiometry (PAR), is presented in the context of field monitoring a disposal site. First is presented an historical account describing the site and early monitoring to provide an overview. The intent and nature of the monitoring program changed when it was proposed to expand the Radiological Waste Site close to the Hazardous Waste Site. Both the sampling methods and analysis techniques were refined in the course of this exercise.

  12. The solubility parameter for biomedical polymers-Application of inverse gas chromatography.

    PubMed

    Adamska, K; Voelkel, A; Berlińska, A

    2016-08-05

    The solubility parameter seems to be a useful tool for thermodynamic characterisation of different materials. The solubility parameter concept can be used to predict sufficient miscibility or solubility between a solvent and a polymer, as well as components of co-polymer matrix in composite biomaterials. The values of solubility parameter were determined for polycaprolactone (PCL), polylactic acid (PLA) and polyethylene glycol (PEG) by using different procedures and experimental data, collected by means of inverse gas chromatography. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Rapid gas analyses for the investigation of spontaneous combustion using capillary gas chromatography.

    PubMed

    Havenga, W J

    1993-02-01

    A simple and fast but sensitive and precise gas chromatographic method is described for the quantitative determination of O(2), N(2), CO, CO(2), C1 and C2-hydrocarbons for coal research. Gas analyses are necessary to obtain parameters for modelling spontaneous combustion and to predict long term coal behaviour. The method is based on a single PLOT-type capillary column in a single channel gas chromatograph. Using a micro-volume TCD coupled in series with a FID detector containing a capillary methanizer it is possible to determine high and trace level gases simultaneously. Trace quantities of CO and CO(2) can be determined with a single analysis and the detection limits are improved significantly using the capillary methanizer. The detection limit of the described method is approximately ten parts per million CO(2) and one part per million CO. Using the same instrument configuration the O(2)/N(2) ratios (major components), as parameter for coal reactivity, are also determined. The proposed approach is restricted to the determination of gases evolved during coal studies and the application to other gas mixtures is not considered.

  14. Detection and quantification of gas-phase oxidized mercury compounds by GC/MS

    NASA Astrophysics Data System (ADS)

    Jones, Colleen P.; Lyman, Seth N.; Jaffe, Daniel A.; Allen, Tanner; O'Neil, Trevor L.

    2016-05-01

    Most mercury pollution is emitted to the atmosphere, and the location and bioavailability of deposited mercury largely depends on poorly understood atmospheric chemical reactions that convert elemental mercury into oxidized mercury compounds. Current measurement methods do not speciate oxidized mercury, leading to uncertainty about which mercury compounds exist in the atmosphere and how oxidized mercury is formed. We have developed a gas chromatography/mass spectrometry (GC-MS)-based system for identification and quantification of atmospheric oxidized mercury compounds. The system consists of an ambient air collection device, a thermal desorption module, a cryofocusing system, a gas chromatograph, and an ultra-sensitive mass spectrometer. It was able to separate and identify mercury halides with detection limits low enough for ambient air collection (90 pg), but an improved ambient air collection device is needed. The GC/MS system was unable to quantify HgO or Hg(NO3)2, and data collected cast doubt upon the existence of HgO in the gas phase.

  15. [Rapid determination of pesticide multiresidues in porphyra by dispersive solid-phase extraction coupled with online gel permeation chromatography-gas chromatography-mass spectrometry].

    PubMed

    Sun, Xiaojie; Guo, Mengmeng; Wang, Suyue; Tan, Zhijun; Li, Zhaoxin; Zhai, Yuxiu

    2014-10-01

    A rapid method for the simultaneous identification and quantification of pesticide multiresidues in porphyra was developed using gel permeation chromatography (GPC) coupled to gas chromatography-mass spectrometry (GPC-GC/MS). Nineteen pesticides (organochlorines, organophosphoruses, triazines and pyrethroids) were selected as the target analytes. The pretreatment method was applied consisting of organic solvent extraction followed by dispersive solid-phase extraction with graphitized carbon black (GCB) and primary secondary amine (PSA) adsorbents. GPC was also employed online to remove the large molecules such as pigments and lipids. The quantitative analysis was carried out by external standard method using gas chromatography coupled with mass spectrometry in selective ion monitoring (SIM) mode. Moreover, a large volume of sample was allowed to be injected using the program of GPC programmed-temperature vaporizer of gas chromatography to improve the sensitivity of measurements. The results showed that the calibration curves were linear (r > 0.995) in the range of 10-1,000 μg/L for all the pesticides. The limits of detection (LODs) for the pesticides in porphyra were from 0.005 to 0.03 mg/kg, and the average recoveries were between 70% and 120%. The advantages of the method are simple, sensitive and shorter operation time for analysis of pesticide residues in porphyra samples.

  16. Enantiomeric analysis of limonene and carvone by direct introduction of aromatic plants into multidimensional gas chromatography.

    PubMed

    Barba, C; Toledano, R M; Santa-María, G; Herraiz, M; Martínez, R M

    2013-03-15

    Analysis of chiral compounds in complex mixtures is achieved by multidimensional gas chromatography using heptakis-(2,3,6-tri-O-methyl)-β-cyclodextrin stationary phase as the main column of the system to separate specific selected cuts containing components unresolved in the first dimension. The proposed procedure allows rapid analysis of both solid and liquid matrices by direct introduction, into the programmed temperature vaporizer (PTV) of a gas chromatograph, of either the plant material or the essential oil, respectively. A comparison between enantiomeric excesses data obtained, from plant leaves (or plant seeds) and the corresponding essential oils, by direct injection (i.e., without sample pretreatment or concentration step) into the multidimensional system is also included. Reported data demonstrate that no racemization occurs during analysis as identical enantiomeric excesses are obtained in both cases for specific chiral compounds.

  17. Determination of oleamide and erucamide in polyethylene films by pressurised fluid extraction and gas chromatography.

    PubMed

    Garrido-López, Alvaro; Esquiu, Vanesa; Tena, María Teresa

    2006-08-18

    A pressurized fluid extraction (PFE) and gas chromatography-flame ionization detection (GC-FID) method is proposed to determine the slip agents in polyethylene (PE) films. The study of PFE variables was performed using a fractional factorial design (FFD) for screening and a central composite design (CCD) for optimizing the main variables obtained from the Pareto charts. The variables that were studied include temperature, static time, percentage of cyclohexane and the number of extraction cycles. The final condition selected was pure isopropanol (two times) at 105 degrees C for 16min. The recovery of spiked oleamide and erucamide was around 100%. The repeatability of the method was between 9.6% for oleamide and 8% for erucamide, expressed as relative standard deviation. Finally, the method was applied to determine oleamide and erucamide in several polyethylene films and the results were statistically equal to those obtained by pyrolysis and gas-phase chemiluminescence (CL).

  18. Rapid determination of cholesterol in milk and milk products by direct saponification and capillary gas chromatography.

    PubMed

    Fletouris, D J; Botsoglou, N A; Psomas, I E; Mantis, A I

    1998-11-01

    A simple method is described for the determination of cholesterol in milk and milk products. Samples (0.2 g) are saponified in capped tubes with 0.5 M methanolic KOH solution by heating for 15 min at 80 degrees C. Water is added to the mixtures, and the unsaponifiable fractions are extracted with hexane to be further analyzed by capillary gas chromatography. Because of the rapid sample preparation and gas chromatographic procedures, a single sample can be analyzed in 30 min. Overall recovery was 98.6%, and the linearity was excellent for the fortification range examined. Precision data that were based on the variation within and between days suggested an overall relative standard deviation value of 1.4%. The method has been successfully applied to quantitate cholesterol in a variety of milk products.

  19. A sensitive gas chromatography detector based on atmospheric pressure chemical ionization by a dielectric barrier discharge.

    PubMed

    Kirk, Ansgar T; Last, Torben; Zimmermann, Stefan

    2017-02-03

    In this work, we present a novel concept for a gas chromatography detector utilizing an atmospheric pressure chemical ionization which is initialized by a dielectric barrier discharge. In general, such a detector can be simple and low-cost, while achieving extremely good limits of detection. However, it is non-selective apart from the use of chemical dopants. Here, a demonstrator manufactured entirely from fused silica capillaries and printed circuit boards is shown. It has a size of 75×60×25mm(3) and utilizes only 2W of power in total. Unlike other known discharge detectors, which require high-purity helium, this detector can theoretically be operated using any gas able to form stable ion species. Here, purified air is used. With this setup, limits of detection in the low parts-per-billion range have been obtained for acetone.

  20. Forensic analysis of ignitable liquids in fire debris by comprehensive two-dimensional gas chromatography.

    PubMed

    Frysinger, Glenn S; Gaines, Richard B

    2002-05-01

    The application of comprehensive two-dimensional gas chromatography (GC x GC) for the forensic analysis of ignitable liquids in fire debris is reported. GC x GC is a high resolution, multidimensional gas chromatographic method in which each component of a complex mixture is subjected to two independent chromatographic separations. The high resolving power of GC x GC can separate hundreds of chemical components from a complex fire debris extract. The GC x GC chromatogram is a multicolor plot of two-dimensional retention time and detector signal intensity that is well suited for rapid identification and fingerprinting of ignitable liquids. GC x GC chromatograms were used to identify and classify ignitable liquids, detect minor differences between similar ignitable liquids, track the chemical changes associated with weathering, characterize the chemical composition of fire debris pyrolysates, and detect weathered ignitable liquids against a background of fire debris pyrolysates.

  1. Gas-liquid chromatography-mass spectrometry of synthetic ceramides containing phytosphingosine.

    PubMed

    Hammarström, S

    1970-05-01

    Ceramides containing phytosphingosine as base and one of the fatty acids 16:0, 18:0, 20:0, 22:0, 23:0, and 24:0, were prepared by direct coupling in the presence of a mixed carbodiimide. The ceramides were analyzed as the 1,3,4-tri-O-trimethylsilyl ether derivatives by gas-liquid chromatography-mass spectrometry. Gas chromatographic data is presented, and structures of mass spectral ions are suggested. The structures are supported by mass spectra of the homologous ceramides, by deuterium-labeling experiments, and by high resolution mass spectrometry. Some ions, formed by cleavage between C-3 and C-4 in the long-chain base, indicate the phytosphingosine nature of the ceramide.

  2. Determination of ethanol in chocolate shell pralines and filled chocolates by capillary gas chromatography.

    PubMed

    Pintarić, I K

    1999-03-01

    The paper describes a simple gas chromatographic method for quantification of ethanol in distillates of chocolate shell pralines and fillings. The samples were prepared in two steps. The first step consisted of ethanol distillation from the product and the second involved capillary gas chromatography of 10% v/v distillate with expected ethanol content between 0.06% and 2.5% w/w. Quantification was carried out using iso-propanol as internal standard. The range of linear method response was 0.05-3.16% w/w of ethanol, which corresponded to products with ethanol content between 0.5 and 31.6% w/w. The detection limit was 0.0158% w/w and the quantification limit was 0.058% w/w of ethanol with the relative standard deviation of 2.5%.

  3. Direct determination of volatile compounds in spirit drinks by gas chromatography.

    PubMed

    Charapitsa, Siarhei V; Kavalenka, Anton N; Kulevich, Nikita V; Makoed, Nicolai M; Mazanik, Arkadzi L; Sytova, Svetlana N; Zayats, Natalia I; Kotov, Yurii N

    2013-03-27

    A way of direct determination of volatile compounds in spirit drinks by gas chromatography is proposed by using ethanol as internal standard in gas chromatographic analysis of volatile compounds in spirit drinks for routine tests. This method provides determination of volatile compound concentrations in spirit drinks expressed directly in milligrams per liter of absolute alcohol without measuring the alcohol content of the analyzed sample. Theoretical background of the method shows the opportunity to use it in any tested laboratories all over the world and to ascertain in its efficiency and simplicity. The method was approved in control laboratories of Wine and Distillery Plant "Chashniki" (Belarus) and Branch of Joint Stock Company "Rosspirtprom" Wine and Distillery Plant "Cheboksary" (Russia). The experimental results of method validation in the Laboratory of Analytical Research from Research Institute for Nuclear Problems of Belarusian State University are presented.

  4. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Hladik, Michelle; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  5. Pseudo-absolute quantitative analysis using gas chromatography - Vacuum ultraviolet spectroscopy - A tutorial.

    PubMed

    Bai, Ling; Smuts, Jonathan; Walsh, Phillip; Qiu, Changling; McNair, Harold M; Schug, Kevin A

    2017-02-08

    The vacuum ultraviolet detector (VUV) is a new non-destructive mass sensitive detector for gas chromatography that continuously and rapidly collects full wavelength range absorption between 120 and 240 nm. In addition to conventional methods of quantification (internal and external standard), gas chromatography - vacuum ultraviolet spectroscopy has the potential for pseudo-absolute quantification of analytes based on pre-recorded cross sections (well-defined absorptivity across the 120-240 nm wavelength range recorded by the detector) without the need for traditional calibration. The pseudo-absolute method was used in this research to experimentally evaluate the sources of sample loss and gain associated with sample introduction into a typical gas chromatograph. Standard samples of benzene and natural gas were used to assess precision and accuracy for the analysis of liquid and gaseous samples, respectively, based on the amount of analyte loaded on-column. Results indicate that injection volume, split ratio, and sampling times for splitless analysis can all contribute to inaccurate, yet precise sample introduction. For instance, an autosampler can very reproducibly inject a designated volume, but there are significant systematic errors (here, a consistently larger volume than that designated) in the actual volume introduced. The pseudo-absolute quantification capability of the vacuum ultraviolet detector provides a new means for carrying out system performance checks and potentially for solving challenging quantitative analytical problems. For practical purposes, an internal standardized approach to normalize systematic errors can be used to perform quantitative analysis with the pseudo-absolute method. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Determination of Free Fatty Acids and Triglycerides by Gas Chromatography Using Selective Esterification Reactions

    SciTech Connect

    Kail, Brian W; Link, Dirk D; Morreale, Bryan D

    2012-11-01

    A method for selectively determining both free fatty acids (FFA) and triacylglycerides (TAGs) in biological oils was investigated and optimized using gas chromatography after esterification of the target species to their corresponding fatty acid methyl esters (FAMEs). The method used acid catalyzed esterification in methanolic solutions under conditions of varying severity to achieve complete conversion of more reactive FFAs while preserving the concentration of TAGs. Complete conversion of both free acids and glycerides to corresponding FAMEs was found to require more rigorous reaction conditions involving heating to 120°C for up to 2 h. Method validation was provided using gas chromatography–flame ionization detection, gas chromatography–mass spectrometry, and liquid chromatography–mass spectrometry. The method improves on existing methods because it allows the total esterified lipid to be broken down by FAMEs contributed by FFA compared to FAMEs from both FFA and TAGs. Single and mixed-component solutions of pure fatty acids and triglycerides, as well as a sesame oil sample to simulate a complex biological oil, were used to optimize the methodologies. Key parameters that were investigated included: HCl-to-oil ratio, temperature and reaction time. Pure free fatty acids were found to esterify under reasonably mild conditions (10 min at 50°C with a 2.1:1 HCl to fatty acid ratio) with 97.6 ± 2.3% recovery as FAMEs, while triglycerides were largely unaffected under these reaction conditions. The optimized protocol demonstrated that it is possible to use esterification reactions to selectively determine the free acid content, total lipid content, and hence, glyceride content in biological oils. This protocol also allows gas chromatography analysis of FAMEs as a more ideal analyte than glyceride species in their native state.

  7. Characterization of crude oil biomarkers using comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry.

    PubMed

    Mogollón, Noroska Gabriela Salazar; Prata, Paloma Santana; Dos Reis, Jadson Zeni; Neto, Eugênio Vaz Dos Santos; Augusto, Fabio

    2016-09-01

    Oil samples from Recôncavo basin (NE Brazil), previously analyzed by traditional techniques such as gas chromatography coupled to tandem mass spectrometry, were evaluated using comprehensive two-dimensional gas chromatography coupled to quadrupole mass spectrometry and comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry along with simplified methods of samples preparation to evaluate the differences and advantages of these analytical techniques to better understand the development of the organic matter in this basin without altering the normal distribution of the compounds in the samples. As a result, the geochemical parameters calculated by comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry described better the origin, maturity, and biodegradation of both samples probably by increased selectivity, resolution, and sensitivity inherent of the multidimensional technique. Additionally, the detection of the compounds such as, the C(14α-) homo-26-nor-17α-hopane series, diamoretanes, nor-spergulanes, C19 -C26 A-nor-steranes and 4α-methylsteranes resolved and detected by comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry were key to classify and differentiate these lacustrine samples according to their maturity and deposition conditions.

  8. Achieving high peak capacity production for gas chromatography and comprehensive two-dimensional gas chromatography by minimizing off-column peak broadening.

    PubMed

    Wilson, Ryan B; Siegler, W Christopher; Hoggard, Jamin C; Fitz, Brian D; Nadeau, Jeremy S; Synovec, Robert E

    2011-05-27

    By taking into consideration band broadening theory and using those results to select experimental conditions, and also by reducing the injection pulse width, peak capacity production (i.e., peak capacity per separation time) is substantially improved for one dimensional (1D-GC) and comprehensive two dimensional (GC×GC) gas chromatography. A theoretical framework for determining the optimal linear gas velocity (the linear gas velocity producing the minimum H), from experimental parameters provides an in-depth understanding of the potential for GC separations in the absence of extra-column band broadening. The extra-column band broadening is referred to herein as off-column band broadening since it is additional band broadening not due to the on-column separation processes. The theory provides the basis to experimentally evaluate and improve temperature programmed 1D-GC separations, but in order to do so with a commercial 1D-GC instrument platform, off-column band broadening from injection and detection needed to be significantly reduced. Specifically for injection, a resistively heated transfer line is coupled to a high-speed diaphragm valve to provide a suitable injection pulse width (referred to herein as modified injection). Additionally, flame ionization detection (FID) was modified to provide a data collection rate of 5kHz. The use of long, relatively narrow open tubular capillary columns and a 40°C/min programming rate were explored for 1D-GC, specifically a 40m, 180μm i.d. capillary column operated at or above the optimal average linear gas velocity. Injection using standard auto-injection with a 1:400 split resulted in an average peak width of ∼1.5s, hence a peak capacity production of 40peaks/min. In contrast, use of modified injection produced ∼500ms peak widths for 1D-GC, i.e., a peak capacity production of 120peaks/min (a 3-fold improvement over standard auto-injection). Implementation of modified injection resulted in retention time, peak width

  9. In situ search for organics by gas chromatography analysis: new derivatization / thermochemolysis approach

    NASA Astrophysics Data System (ADS)

    Geffroy, Claude; Buch, Arnaud; David, Marc; Aissat, Lyes; El Mufleh, Amel; Papot, S.; Sternberg, Robert

    Many organic molecules are present in interstellar clouds and might be carried to the early Earth by comets and meteorites during the heavy bombardment phase in the first few hundred million years of the solar system. It has been suggested that extraterrestrial organic material may well represent an important part of the organic material available for the origin of life. Until samples, brought by future space missions, are available on Earth, in situ measurements are one of the way to get unaltered and non-contaminated samples for analysis. The analytical technique has to be robust, sensitive and non-specific due to the large scope of targets molecules. The only currently flight qualified technique of analysis of organic molecules in space is gas chromatography (Viking, Cassini-Huygens, SAM-MSL, COSAC-Rosetta). The main objective of this work is to present a new approach with multi step analysis using derivatisation and thermochemolysis reagents for a one pot in situ analysis of volatile and refractory organics in surface or sub-surface samples (Mars, comets).Indeed, no single technology enables to identify all organic compounds because naturally occurring molecules have different polarities, molecular weights, being extractible or recalcitrant, bonded trapped or adsorbed on minerals. Thus, we propose to wider the scope of chemical reagent already validated for in situ wet chemistry such as MTBSTFA (Rodier et al. 2001, 2002), DMF-DMA (Rodier et al. 2002), or TMAH (Rodier et al, 2005, Geffroy-Rodier et al; 2009) to analyze enantiomers of amino acids, carbohydrates and lipids in a one pot several steps sub system using a multi reagent and multi step approach. Thus using a new derivatizing agent, we successfully identified twenty one amino acids including twelve of the twenty proteinic amino acids without inhibiting following multi step thermochemolysis. *Geffroy-Rodier C, Grasset L, Sternberg R. Buch A. Amblès A. (2009) Thermochemolysis in search for organics in

  10. Aroma characterization of tangerine hybrids by gas-chromatography-olfactometry and sensory evaluation.

    PubMed

    Miyazaki, Takayuki; Plotto, Anne; Baldwin, Elizabeth A; Reyes-De-Corcuera, José I; Gmitter, Fred G

    2012-03-15

    Tangerines have a distinct flavor among citrus fruit. However, information on tangerine volatiles remains limited. Volatile compounds from a breeding population of tangerines were earlier identified by gas chromatography-mass spectrometry. In this study, five hybrids with a distinct volatile profile were analyzed by gas-chromatography-olfactometry (GC-O) and descriptive sensory analysis. Forty-nine aroma active compounds were found in a consensus by GC-O. Aldehydes were the most important group with odor activity, as well as monoterpenes, esters, alcohols and ketones. 1,8-Cineole, β-myrcene, (E,E)-2,4-nonadienal, hexanal, ethyl-2-methylbutanoate, and linalool were perceived with high intensity in most samples. Two 'Clementine' × 'Minneola' and one 'Fortune' × 'Murcott' hybrids with tangerine, sulfury and woody/spicy flavors had aroma active compounds with terpeney, fatty/vegetable and metallic/rubber descriptors. A tangerine with 'Valencia' orange in its parentage had a characteristic orange flavor, which could be explained by esters and ketones, high in fruity and floral odor intensities. A hybrid of unknown origin had a distinct fruity-non-citrus and pumpkin/fatty flavor; that sample had the lowest amount of aroma-active volatiles, with the least compounds with terpeney odors. There was no one compound characteristic of tangerine flavor. Nevertheless, each sample sensory characteristic could be explained by a set of aroma-active volatile compounds.

  11. Gas chromatography with flame photometric detection of 31 organophosphorus pesticide residues in Alpinia oxyphylla dried fruits.

    PubMed

    Zhao, Xiangsheng; Kong, Weijun; Wei, Jianhe; Yang, Meihua

    2014-11-01

    A simple, rapid and effective gas chromatography-flame photometric detection method was established for simultaneous multi-component determination of 31 organophosphorus pesticides (OPPs) residues in Alpinia oxyphylla, which is widely consumed as a traditional medicine and food in China. Sample preparation was completed in a single step without any clean-up procedure. All pesticides expressed good linear relationships between 0.004 and 1.0 μg/mL with correlation coefficients higher than 0.9973. The method gave satisfactory recoveries for most pesticides. The limits of detection varied from 1 to 10 ng/mL, and the limits of quantification (LOQs) were between 4 and 30 ng/mL. The proposed method was successfully applied to 55 commercial samples purchased from five different areas. Five pesticide residues were detected in four (7.27%) samples. The positive samples were confirmed by gas chromatography with tandem mass spectrometry (GC-MS/MS). Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Isotope dilution gas chromatography/mass spectrometry method for determination of pyrethroids in apple juice.

    PubMed

    Wong, Siu-kay; Yu, Kwok-chiu; Lam, Chi-ho

    2010-03-01

    This paper presents the development of a highly precise and accurate analytical method for the determination of three matrix-bound pyrethroids, namely, cypermethrin, permethrin, and bifenthrin, using an isotope dilution gas chromatography/mass spectrometry technique. Identification of the analytes was confirmed under selective ion monitoring mode by the presence of two dominant ion fragments within specific time windows and matching of relative ion intensities of the ions concerned in samples and calibration standards. Quantitation was based on the measurement of concentration ratios of the natural and isotope analogues in the sample and calibration blends. Intraday and interday repeatabilities of replicate analyses of the pyethroids in an apple juice sample were below 0.5%. The expanded relative uncertainty ranged from 3 to 6%, which was significantly lower than the range obtained using internal or external calibration methods. As a labeled analogue is not available for bifenthrin, bifenthrin was determined using labeled cis-permethrin as the internal standard. The results were counterchecked by a gas chromatography-electron capture detection technique using PCB 209 as the internal standard. The method developed was applied to a recent pilot study organized by CCQM and the results were consistent with those of other participants.

  13. Zeolitic imidazolate framework-methacrylate composite monolith characterization by inverse gas chromatography.

    PubMed

    Yusuf, Kareem; Badjah-Hadj-Ahmed, Ahmed Yacine; Aqel, Ahmad; Aouak, Taieb; ALOthman, Zeid Abdullah

    2016-04-22

    Thermodynamic characterization of butyl methacrylate-co-ethylene dimethacrylate neat monolith and zeolitic imidazolate framework-8 incorporated with butyl methacrylate-co-ethylene dimethacrylate composite monolith were studied using inverse gas chromatography at infinite dilution under 1MPa column pressure and various column temperatures. The free energy of adsorption (ΔGA), enthalpy of adsorption (ΔHA) and entropy of adsorption (ΔSA) were determined using a series of n-alkanes. The dispersive component of surface energy (γS(D)) was estimated by Dorris-Gray and Schultz et al. The composite monolith showed a more energetic surface than the neat monolith. The acidic, KA, and basic, KD, parameters for both materials were estimated using a group of polar probes. A basic character was concluded with more basic behavior for the neat monolith. Flory-Huggins parameter, χ, was taken as a measure of miscibility between the probes with the low molecular weight and the high molecular weight monolith. Inverse gas chromatography provides a better understanding of the role of incorporated zeolitic imidazolate framework (ZIF-8) into the polymer matrix in its monolithic form. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Resolution of isomeric new designer stimulants using gas chromatography - Vacuum ultraviolet spectroscopy and theoretical computations.

    PubMed

    Skultety, Ludovit; Frycak, Petr; Qiu, Changling; Smuts, Jonathan; Shear-Laude, Lindsey; Lemr, Karel; Mao, James X; Kroll, Peter; Schug, Kevin A; Szewczak, Angelica; Vaught, Cory; Lurie, Ira; Havlicek, Vladimir

    2017-06-08

    Distinguishing isomeric representatives of "bath salts", "plant food", "spice", or "legal high" remains a challenge for analytical chemistry. In this work, we used vacuum ultraviolet spectroscopy combined with gas chromatography to address this issue on a set of forty-three designer drugs. All compounds, including many isomers, returned differentiable vacuum ultraviolet/ultraviolet spectra. The pair of 3- and 4-fluoromethcathinones (m/z 181.0903), as well as the methoxetamine/meperidine/ethylphenidate (m/z 247.1572) triad, provided very distinctive vacuum ultraviolet spectral features. On the contrary, spectra of 4-methylethcathinone, 4-ethylmethcathinone, 3,4-dimethylmethcathinone triad (m/z 191.1310) displayed much higher similarities. Their resolution was possible only if pure standards were probed. A similar situation occurred with the ethylone and butylone pair (m/z 221.1052). On the other hand, majority of forty-three drugs was successfully separated by gas chromatography. The detection limits for all the drug standards were in the 2-4 ng range (on-column amount), which is sufficient for determinations of seized drugs during forensics analysis. Further, state-of-the-art time-dependent density functional theory was evaluated for computation of theoretical absorption spectra in the 125-240 nm range as a complementary tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Simultaneous determination of three organophosphorus pesticides in different food commodities by gas chromatography with mass spectrometry.

    PubMed

    Vijaya Bhaskar Reddy, Ambavaram; Yusop, Zulkifli; Jaafar, Jafariah; Bin Aris, Azmi; Abdul Majid, Zaiton; Umar, Khalid; Talib, Juhaizah

    2016-06-01

    A sensitive and selective gas chromatography with mass spectrometry method was developed for the simultaneous determination of three organophosphorus pesticides, namely, chlorpyrifos, malathion, and diazinon in three different food commodities (milk, apples, and drinking water) employing solid-phase extraction for sample pretreatment. Pesticide extraction from different sample matrices was carried out on Chromabond C18 cartridges using 3.0 mL of methanol and 3.0 mL of a mixture of dichloromethane/acetonitrile (1:1 v/v) as the eluting solvent. Analysis was carried out by gas chromatography coupled with mass spectrometry using selected-ion monitoring mode. Good linear relationships were obtained in the range of 0.1-50 μg/L for chlorpyrifos, and 0.05-50 μg/L for both malathion and diazinon pesticides. Good repeatability and recoveries were obtained in the range of 78.54-86.73% for three pesticides under the optimized experimental conditions. The limit of detection ranged from 0.02 to 0.03 μg/L, and the limit of quantification ranged from 0.05 to 0.1 μg/L for all three pesticides. Finally, the developed method was successfully applied for the determination of three targeted pesticides in milk, apples, and drinking water samples each in triplicate. No pesticide was found in apple and milk samples, but chlorpyrifos was found in one drinking water sample below the quantification level.

  16. Detection for Non-Milk Fat in Dairy Product by Gas Chromatography

    PubMed Central

    2016-01-01

    The aim of this study was to evaluate the potential use of fatty acids, triacylglycerols, and cholesterol in the detection of adulterated milk fat. The fatty acid, triacylglycerol, and cholesterol profiles of the mixtures of milk and non-milk fat (adulteration ratios of 10%, 30%, 50%, 70%, and 90%) were analyzed by gas chromatography. The results showed that concentrations of the fatty acids with oleic acid (C18:1n9c) and linoleic acid (C18:2n6c), triglycerides with C52 and C54, and cholesterol detected are proportional to the adulteration ratios remarkably. Oleic acid (C18:1n9c), linoleic acid (C18:2n6c), C52, and C54 were lower in pure milk fat than in adulterated mixtures. In contrast, pure milk has a higher cholesterol concentration than all adulterated mixtures (adulteration concentration in the range 10-90%). Thus, we suggest that oleic acid (C18:1n9c), linoleic acid (C18:2n6c), C52, C54, and cholesterol are suitable indicators and can be used as biomarkers to rapidly detect adulterated milk fat by gas chromatography. This study is expected to provide basic data for adulteration and material usage. Moreover, this new approach can detect the presence of foreign oils and fats in the milk fat of cheese and can find application in related studies. PMID:27194929

  17. Gas chromatography with diode array detection in series with flame ionisation detection.

    PubMed

    Gras, Ronda; Luong, Jim; Shellie, Robert A

    2017-06-02

    We introduce a gas chromatography detection approach that uses diode array detection operated in series with flame ionisation detection and demonstrate the utility of the detection approach for determination of volatile organic compounds. Diode array detection brings ultraviolet - visible spectroscopy (over a range of 190-640nm) onto the capillary gas chromatography time-scale, where average peak widths of analytes are on the order of 3-5s. The non-destructive nature of the diode array detector affords serially-coupled flame ionisation detection. This arrangement delivers near-simultaneous selective and universal detection without incurring additional analytical time, and without recourse to column flow splitting. The hyphenated technique is shown to be effective for chromatographic applications spanning an equivalent volatility range from C1 to C7n-paraffin hydrocarbons. The approach introduced herein provides increased sensitivity and selectivity for classes of compounds amenable to electronic spectroscopy such as alkenes, dienes, sulfurs, and aromatic compounds. The approach is demonstrated for direct measurement of carbon disulfide in work place atmospheres with a detection limit of 93pg on column and for the direct measurement of 1,3-butadiene in hydrocarbon matrices and ambient air with a detection of 73pg on column, each in less than 5min. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Gas chromatography-mass spectrometry determination of phosphine residues in stored products and processed foods.

    PubMed

    Norman, K N; Leonard, K

    2000-09-01

    A gas chromatography-mass spectrometry (GC-MS) method was used for the quantitative confirmation of phosphine residues in stored products and processed foods. An established extraction technique was utilized for the preparation of headspace samples, which were analyzed by GC-MS and gas chromatography-nitrogen-phosphorus detection (GC-NPD). Wheat, oats, maize, white rice, brown rice, cornflakes, tortilla cornchips, groundnuts, and raisins were validated, showing excellent agreement between detectors when spiked at levels equivalent to 0.001 and 0.01 mg/kg phosphine and for samples containing incurred residues. The GC-MS method was reproducible and accurate when compared to the GC-NPD method and allowed five samples to be quantified in a working day. Subambient GC-MS oven temperatures were most suitable for phosphine residues ranging from 0.001 to 0.005 mg/kg, and a GC oven temperature of 100 degrees C was appropriate for residues >0.005 mg/kg. The method was sufficiently robust to be evaluated for other similar commodities as the need arises.

  19. Optimizing 2D gas chromatography mass spectrometry for robust tissue, serum and urine metabolite profiling.

    PubMed

    Yu, Zhanru; Huang, Honglei; Reim, Alexander; Charles, Philip D; Northage, Alan; Jackson, Dianne; Parry, Ian; Kessler, Benedikt M

    2017-04-01

    Two-dimensional gas chromatography mass spectrometry (GCxGC-MS) is utilized to an increasing extent in biomedical metabolomics. Here, we established and adapted metabolite extraction and derivatization protocols for cell/tissue biopsy, serum and urine samples according to their individual properties. GCxGC-MS analysis revealed detection of ~600 molecular features from which 165 were characterized representing different classes such as amino acids, fatty acids, lipids, carbohydrates, nucleotides and small polar components of glycolysis and the Krebs cycle using electron impact (EI) spectrum matching and validation using external standard compounds. Advantages of two-dimensional gas chromatography based resolution were demonstrated by optimizing gradient length and separation through modulation between the first and second column, leading to a marked increase in metabolite identification due to improved separation as exemplified for lactate versus pyruvate, talopyranose versus methyl palmitate and inosine versus docosahexaenoic acid. Our results demonstrate that GCxGC-MS represents a robust metabolomics platform for discovery and targeted studies that can be used with samples derived from the clinic. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Determination of toxaphene enantiomers by comprehensive two-dimensional gas chromatography with electron-capture detection.

    PubMed

    Bordajandi, Luisa R; Ramos, Lourdes; González, María José

    2006-09-01

    Comprehensive two-dimensional gas chromatography with micro electron-capture detection (GC x GC-microECD) has been evaluated for the enantioseparation of five chiral toxaphenes typically found in real-life samples (Parlar 26, 32, 40, 44 and 50). From the two enantioselective beta-cyclodextrin-based columns evaluated as first dimension column, BGB-176SE and BGB-172, the latter provided the best results and was further combined with three non-enantioselective columns in the second dimension: HT-8, BPX-50 and Supelcowax-10. The combination BGB-172 x BPX-50 was finally selected because it provided a complete separation among all enantiomers. A satisfactory repeatability and reproducibility of the retention times in both the first and the second dimension were observed for all target compounds (RSDs below 0.8%, n = 4). Linear responses in the tested range of 10-200 pg/microl and limits of detection in the range of 2-6 pg/microl were obtained. The repeatability and reproducibility at a concentration of 100 pg/microl, evaluated as the RSDs calculated for the enantiomeric fraction (EF), was better than 11% (n = 4) in all instances. The feasibility of the method developed for real-life analyses was illustrated by the determination of the enantiomeric ratios and concentration levels of the test compounds in four commercial fish oil samples. These results were compared to those obtained by heart-cut multidimensional gas chromatography using the same enantioselective column.

  1. Chemical warfare agent detection in complex environments with comprehensive two-dimensional gas chromatography

    NASA Astrophysics Data System (ADS)

    Reichenbach, Stephen E.; Ni, Mingtian; Kottapalli, Visweswara; Visvanathan, Arvind; Ledford, Edward B., Jr.; Oostdijk, John; Trap, Henk C.

    2003-08-01

    Comprehensive two-dimensional gas chromatography (GCxGC) is an emerging technology for chemical separation that provides an order-of-magnitude increase in separation capacity over traditional gas chromatography. GCxGC separates chemical species with two capillary columns interfaced by two-stage thermal desorption. Because GCxGC is comprehensive and has high separation capacity, it can perform multiple traditional analytical methods with a single analysis. GCxGC has great potential for a wide variety of environmental sensing applications, including detection of chemical warfare agents (CWA) and other harmful chemicals. This paper demonstrates separation of nerve agents sarin and soman from a matrix of gasoline and diesel fuel. Using a combination of an initial column separating on the basis of boiling point and a second column separating on the basis of polarity, GCxGC clearly separates the nerve agents from the thousands of other chemicals in the sample. The GCxGC data is visualized, processed, and analyzed as a two-dimensional digital image using a software system for GCxGC image processing developed at the University of Nebraska - Lincoln.

  2. Oxysterols in cosmetics-Determination by planar solid phase extraction and gas chromatography-mass spectrometry.

    PubMed

    Schrack, S; Hohl, C; Schwack, W

    2016-11-18

    Sterol oxidation products (SOPs) are linked to several toxicological effects. Therefore, investigation of potential dietary uptake sources particularly food of animal origin has been a key issue for these compounds. For the simultaneous determination of oxysterols from cholesterol, phytosterols, dihydrolanosterol and lanosterol in complex cosmetic matrices, planar solid phase extraction (pSPE) was applied as clean-up tool. SOPs were first separated from more non-polar and polar matrix constituents by normal phase thin-layer chromatography and then focussed into one target zone. Zone extraction was performed with the TLC-MS interface, followed by gas chromatography-mass spectrometry analysis. pSPE showed to be effective for cleaning up cosmetic samples as sample extracts were free of interferences, and gas chromatographic columns did not show any signs of overloading. Recoveries were between 86 and 113% with relative standard deviations of below 10% (n=6). Results of our market survey in 2016 showed that some cosmetics with ingredients of plant origin contained phytosterol oxidation products (POPs) in the low ppm range and therefore in line with levels reported for food. In lanolin containing products, total SOPs levels (cholesterol oxidation products (COPs), lanosterol oxidation products (LOPs), dihydrolanosterol oxidation products (DOPs)) being in the low percent range exceeded reported levels for food by several orders of magnitudes. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Identification and deconvolution of carbohydrates with gas chromatography-vacuum ultraviolet spectroscopy.

    PubMed

    Schenk, Jamie; Nagy, Gabe; Pohl, Nicola L B; Leghissa, Allegra; Smuts, Jonathan; Schug, Kevin A

    2017-09-01

    Methodology for qualitative and quantitative determination of carbohydrates with gas chromatography coupled to vacuum ultraviolet detection (GC-VUV) is presented. Saccharides have been intently studied and are commonly analyzed by gas chromatography-mass spectrometry (GC-MS), but not always effectively. This can be attributed to their high degree of structural complexity: α/β anomers from their axial/equatorial hydroxyl group positioning at the C1-OH and flexible ring structures that lead to the open chain, five-membered ring furanose, and six-membered ring pyranose configurations. This complexity can result in convoluted chromatograms, ambiguous fragmentation patterns and, ultimately, analyte misidentification. In this study, mono-, di, and tri-saccharides were derivatized by two different methods-permethylation and oximation/pertrimethylsilylation-and analyzed by GC-VUV. These two derivatization methods were then compared for their efficiency, ease of use, and robustness. Permethylation proved to be a useful technique for the analysis of ketopentoses and pharmaceuticals soluble in dimethyl sulfoxide (DMSO), while the oximation/pertrimethylsilylation method prevailed as the more promising, overall, derivatization method. VUV spectra have been shown to be distinct and allow for efficient differentiation of isomeric species such as ketopentoses and reducing versus non-reducing sugars. In addition to identification, pharmaceutical samples containing several compounds were derivatized and analyzed for their sugar content with the GC-VUV technique to provide data for qualitative analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Multi-residue determination of pesticides in vegetables by gas chromatography/ion trap mass spectrometry.

    PubMed

    Tao, C-J; Hu, J-Y; Li, J-Z; Zheng, S-S; Liu, W; Li, C-J

    2009-01-01

    To monitor possible contamination of edible vegetables by common pesticides, an analytical method using gas chromatography combined with ion trap spectrometry (GC-IT/MS) was developed to measure simultaneously up to 39 pesticide residues, belonging to organophosphors, organochlorines, pyrethroids or carbamates classes, left on four kinds of popular vegetables. The procedure entails addition of acetone, dichloromethane, and sodium chloride to a small amount of vegetable, then the mixture was shaken intensively and centrifuged for phase separation. An aliquot of the organic layer was cleanup using solid-phase extraction (SPE) cartridges filled with graphitized carbon black (GCB) in combination with acidic aluminum oxide. Gas chromatography with ion trap mass spectrometer was then used for qualitative and quantitative determination of the pesticides. The GCB combination with acidic aluminum oxide was found more suitable than florisil, aluminum oxide and silicon dioxide for sample cleanup with recoveries above 70% for most pesticides in removing the majority of co-extracted matrices. Variation coefficients of the repeatability typically smaller than 20% have been achieved for a wide range of the investigated pesticides. A set of critical instrument parameters for the GC-IT/MS Varian system in the MS mode was established. Based on optimization work conducted in this study, the 39 pesticides were separated successively with the limits of detection between 0.02 and 0.1 mg/kg.

  5. Determination of methomyl in the stomach contents of baited wildlife by gas chromatography-mass spectrometry.

    PubMed

    Buchweitz, John P; Bokhart, Mark; Johnson, Margaret; Lehner, Andreas

    2013-11-01

    The poisoning of wildlife with fly-bait containing the active ingredient methomyl is an intentional and illegal act in many jurisdictions. A case of 2 animals poisoned by methomyl through consumption of tainted bait at multiple stations is described. Although thermally and ultraviolet-labile, methomyl can be identified by gas chromatography-mass spectrometry and is detected in abundance in bait samples; however, it is not readily observed in tissues, owing to its rapid metabolism and elimination. The application of derivatizing functionalities, such as trimethylsilyl groups, stabilizes the methomyl-oxime metabolite to facilitate its detectability during exposure to the relatively harsh conditions of gas chromatography. This brief communication reports on the analytical detection of methomyl in baits and biological samples from poisoned wildlife. Essential to the case were the added determination of a fly-bait coactive ingredient, (Z)-9-tricosene, and identification of a chemical indicator, caffeine, to confirm both the type of pesticide product involved in the poisoning incident and the vehicle used to perpetrate its delivery.

  6. Preparation and characterization of alkyl methacrylate-based monolithic columns for capillary gas chromatography applications.

    PubMed

    Yusuf, Kareem; Aqel, Ahmad; A L Othman, Zeid; Badjah-Hadj-Ahmed, Ahmed Yacine

    2013-08-02

    Gas chromatography (GC) is considered the least common application of both polymer and silica-based monolithic columns. This study describes the fabrication of alkyl methacrylate monolithic materials for use as stationary phases in capillary gas chromatography. Following the deactivation of the capillary surface with 3-(trimethoxysilyl)propyl methacrylate (TMSM), the monoliths were formed by the co-polymerization of either hexyl methacrylate (HMA) or lauryl methacrylate (LMA) with different percentage of ethylene glycol dimethacrylate (EDMA) in presence of an initiator (azobisisobutyronitrile, AIBN) and a mixture of porogens include 1-propanol, 1,4-butanediol and water. The monoliths were prepared in 500mm length capillaries possessing inner diameters of 250μm. The efficiencies of the monolithic columns for low molecular weight compounds significantly improved as the percentage of crosslinker was increased, because of the greater proportion of pores less than 50nm. The columns containing lower percentages of crosslinker were able to rapidly separate a series of 8 alkane members in 0.7min, but the separation was less efficient for the light alkanes. Columns prepared with the lauryl methacrylate monomer yielded a different morphology for the monolith-interconnected channels. The channels were more branched, which increased the separation time, and unlike the other columns, allowed for temperature programming.

  7. Determination of amines used in the oil and gas industry (upstream section) by ion chromatography.

    PubMed

    Kadnar, R

    1999-07-30

    During production and purification of crude oil and natural gas several different amines are used as chemicals or operating materials, e.g. film forming long chain amines as corrosion inhibitors, steam volatile amines for pH correction and corrosion protection, alkanolamines as absorbents in sour gas treatment plants, etc. For analytical checks, e.g. determination of corrosion inhibitor concentration in produced media, classical chemical methods are used predominantly, because most of them can be performed in small field laboratories. Some amines, especially the small molecular aliphatic and heterocyclic amines can also be determined by ion chromatography. In our laboratory two types of separation columns (IonPac CS10 and CS12A) were available for ion chromatographic separation. The analysis of the amines in low-salt-containing water, soft water or steam condensate can be performed without problems. The presence of alkali and/or alkaline earth ions in the sample can lead to coelution with these ions, to poor peak resolution or enhanced analysis times, depending on the chromatographic conditions. This work shows some examples of ion chromatography applications for the determination of low-molecular-mass ethanolamines, morpholine and piperazine and discusses the possible interferences and troubles caused by alkali and alkaline earth ions in the matrix.

  8. Rapid separation of beryllium and lanthanide derivatives by capillary gas chromatography

    SciTech Connect

    Harvey, Scott D.; Lucke, Richard B.; Douglas, Matt

    2012-09-04

    Previous studies describe derivatization of metal ions followed by analysis using gas chromatography, usually on packed columns. In many of these studies, stable and volatile derivatives were formed using fluorinated β-diketonate reagents. This paper extends previous work by investigating separations of the derivatives on small-diameter capillary gas chromatography columns and exploring on-fiber, solid-phase microextraction derivatization techniques for beryllium. The β-diketonate used for these studies was 1,1,1,2,2,6,6,7,7,7-decafluoro-3,5-heptanedione. Derivatization of lanthanides also required addition of a neutral donor, dibutyl sulfoxide, in addition to 1,1,1,2,2,6,6,7,7,7-decafluoro-3,5-heptanedione. Unoptimized separations on a 100-μm i.d. capillary column proved capable of rapid separations (within 15 min) of lanthanide derivatives that are adjacent to one another in the periodic table. Full-scan mass spectra were obtained from derivatives containing 5 ng of each lanthanide. Studies also developed a simple on-fiber solid-phase microextraction derivatization of beryllium. Beryllium could be analyzed in the presence of other alkali earth elements (Ba(II) and Sr(II)) without interference. Finally, extension of the general approach was demonstrated for several additional elements (i.e. Cu(II), Cr(III), and Ga(III)).

  9. Gas chromatography - optical fiber detector for assessment of fatty acids in urban soils.

    PubMed

    Silva, Lurdes; Cachada, Anabela; Pereira, Ruth; Freitas, Ana Cristina; Rocha-Santos, Teresa A P; Panteleitchouk, Teresa S L; Pereira, Maria E; Duarte, Armando Costa

    2011-07-15

    Fatty acids have been used as biomarkers of the microbial community composition of soils and they are usually separated and quantified by gas-chromatography coupled to a flame ionization detector (GC-FID). The aim of this study was to develop, validate and apply a methodology based on gas chromatography coupled to optical fiber detection (GC-OF) for screening five fatty acids used as indicators of fungal and bacterial communities in urban soils. The performance of the GC-OF methodology (optical fiber detector at 1,550 nm) was evaluated by comparison with the GC-FID methodology and it was found that they were comparable in terms of linear range, detection limit and analytical errors. Besides these similar analytical characteristics, the GC-OF is much cheaper than the GC-FID methodology. Different concentrations were determined for each fatty acid indicator which in turn varied significantly between the soil samples analyzed from Lisbon ornamental gardens. Additionally, the GC-OF showed a great potential as alternative for determination of eleven or more fatty acids in urban soils.

  10. Quantification of residual solvents in antibody drug conjugates using gas chromatography.

    PubMed

    Medley, Colin D; Kay, Jacob; Li, Yi; Gruenhagen, Jason; Yehl, Peter; Chetwyn, Nik P

    2014-11-19

    The detection and quantification of residual solvents present in clinical and commercial pharmaceutical products is necessary from both patient safety and regulatory perspectives. Head-space gas chromatography is routinely used for quantitation of residual solvents for small molecule APIs produced through synthetic processes; however residual solvent analysis is generally not needed for protein based pharmaceuticals produced through cultured cell lines where solvents are not introduced. In contrast, antibody drug conjugates and other protein conjugates where a drug or other molecule is covalently bound to a protein typically use solvents such as N,N-dimethylacetamide (DMA), N,N‑dimethylformamide (DMF), dimethyl sulfoxide (DMSO), or propylene glycol (PG) to dissolve the hydrophobic small molecule drug for conjugation to the protein. The levels of the solvent remaining following the conjugation step are therefore important to patient safety as these parental drug products are introduced directly into the patients bloodstream. We have developed a rapid sample preparation followed by a gas chromatography separation for the detection and quantification of several solvents typically used in these conjugation reactions. This generic method has been validated and can be easily implemented for use in quality control testing for clinical or commercial bioconjugated products.

  11. Comprehensive two-dimensional gas chromatography for characterizing mineral oils in foods and distinguishing them from synthetic hydrocarbons.

    PubMed

    Biedermann, Maurus; Grob, Koni

    2015-01-02

    Many foods are contaminated by hydrocarbons of mineral oil or synthetic origin. High performance liquid chromatography on-line coupled with gas chromatography and flame ionization detection (HPLC-GC-FID) is a powerful tool for the quantitative determination, but it would often be desirable to obtain more information about the type of hydrocarbons in order to identify the source of the contamination and specify pertinent legislation. Comprehensive two-dimensional gas chromatography (GC×GC) is shown to produce plots distinguishing mineral oil saturated hydrocarbons (MOSH) from polymer oligomeric saturated hydrocarbons (POSH) and characterizing the degree of raffination of a mineral oil. The first dimension separation occurred on a phenyl methyl polysiloxane, the second on a dimethyl polysiloxane. Mass spectrometry (MS) was used for identification, FID for quantitative determination. This shows the substantial advances in chromatography to characterize complex hydrocarbon mixtures even as contaminants in food. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Retention modeling and retention time prediction in gas chromatography and flow-modulation comprehensive two-dimensional gas chromatography: The contribution of pressure on solute partition.

    PubMed

    Burel, Antoine; Vaccaro, Marie; Cartigny, Yohann; Tisse, Séverine; Coquerel, Gérard; Cardinael, Pascal

    2017-02-17

    This study aims at modelling and predicting solute retention in capillary Gas Chromatography (GC) and Flow Modulation comprehensive GC (FM-GCxGC). A new thermodynamic model, taking into account the effects of temperature and pressure, is proposed to describe the variation of the equilibrium partition constant of a solute during its elution. This retention model was challenged with the classical one, and both were applied to: (i) stationary phase film thickness indirect estimation; (ii) retention time (RT) prediction of a set of 11 model polycyclic aromatic hydrocarbons (PAHs) on the SLB-IL60 and DB-35MS columns, in temperature-programmed mode. Film thickness determination led to values about 2 times lower than those indicated by column nominal dimensions, whatever the employed model. Prediction of retention times in GC led to 0.84 and 0.26% mean errors using the classical and the extended models, respectively. Prediction in GCxGC gave 5.5 and 0.44% mean errors in 1st dimension RTs, and 7.3 and 2.2% mean errors in 2nd dimension RTs, using the classical and the extended models, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Recognition of chitin and proteins in invertebrate cuticles using analytical pyrolysis/gas chromatography and pyrolysis/gas chromatography/mass spectrometry.

    PubMed

    Stankiewicz, B A; Van Bergen, P F; Duncan, I J; Carter, J F; Briggs, D E; Evershed, R P

    1996-01-01

    Flash pyrolysis/gas chromatography (py/GC) and py/GC/mass spectrometry (MS) have been utilized to characterize the cuticles of invertebrates chemically. Pyrolysis products have been identified and assigned to specific cuticular components. Acetylpyridones, acetamidofuran, 3-acetamido-5-methylfuran and 3-acetamido-(2 and 4)-pyrones are proposed as characteristic pyrolysis markers for chitin. Pyrolysis products displaying ions of m/z 70, 154, 168, 194 are thought to derive from diketopiperazine structures and provide potential markers for proteins and peptides in which proline, alanine, valine, arginine and glycine are the dominant amino acids. These products, constituting specific pyrolysis markers for invertebrate cuticles, may reflect the amino acid composition of their constituent structural proteins. The source of the various pyrolysis products of proteins has been verified by pyrolysis of reference proteins, peptides and amino acid mixtures. The presence of additional pyrolysis products related directly to histidine and catechol moieties is consistent with the chemical structure and composition proposed for arthropod cuticles based on recent work utilizing solid state 13C and 15N nuclear magnetic resonance. This study constitutes the first comprehensive chemical characterization of the pyrolysis products of invertebrate cuticles and provides the basis for future investigations requiring qualitative screening for cross-linked chitin and proteins in modern and fossil cuticles and in materials, e.g. geopolymers, that may be derived from them.

  14. Aroma active volatiles in four southern highbush blueberry cultivars determined by gas chromatography-olfactometry (GC-O) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Du, Xiaofen; Rouseff, Russell

    2014-05-21

    Aroma active volatiles in four southern highbush blueberry cultivars ('Prima Dona', 'Jewel', 'Snow Chaser', and 'Kestrel') were determined using solid phase microextraction (SPME) in combination with gas chromatography-olfactometry (GC-O) and identified via GC-PFPD and GC-MS using retention indices of reference compounds and mass spectral data. The aromas of total, unseparated SPME extracts evaluated using GC-O were rated 8.2-9.0/10 for the four cultivars in terms of similarity to the original blueberry homogenates. In terms of GC-O aroma similarity, those aroma active volatile groups characterized as green, fruity, and floral were most intense. Of the 43 volatiles found to have aroma activity, 38 were identified and 13 had not been previously reported in blueberries. Although linalool and (E)-2-hexenal were common major aroma impact volatiles, dominant aroma-active volatiles were different for each cultivar. Principal component analysis confirmed that each cultivar possessed a unique aroma active profile as each cultivar was clustered into a separate score plot quadrant.

  15. Determination of pentachlorophenol residue in meat and fish by gas chromatography-electron capture detection and gas chromatography-mass spectrometry with accelerated solvent extraction.

    PubMed

    Zhao, Dongmei

    2014-01-01

    A novel analytical method, using gas chromatography-electron capture detection (GC-ECD) and GC-mass spectrometry detection (MS), was developed for the qualitative and quantitative measurement of pentachlorophenol in meat and fish. The analyte was extracted by methanol-2% trichloroacetic acid (3/1, v/v) with accelerated solvent extraction (ASE). The eluted fraction was evaporated and derivatized with acetic anhydride-pyridine (1/1, v/v) for GC-ECD analysis and GC-MS confirmation. The parameters for extraction pressure, temperature and cycle of ASE, cleanup, derivatization and analysis procedure were optimized. The averaged decision limits and detection capability of the method were in the ranges of 0.25-0.41 and 0.49-1.01 µg/kg in the muscle and liver of swine and bovine and in the muscle of carp and finless eel, respectively. Spiked recoveries from levels of 0.5-2.0 µg/kg were found to be more than 71.1%, with relative standard deviation less than 14.7% in GC-ECD and GC-MS. This rapid and reliable method can be used for the characterization and quantification of residues of pentachlorophenol in animal and fish tissues.

  16. Identification of Aroma-active Compounds in Essential Oil from Uncaria Hook by Gas Chromatography- Mass Spectrometry and Gas Chromatography-Olfactometry.

    PubMed

    Iwasa, Megumi; Nakaya, Satoshi; Maki, Yusuke; Marumoto, Shinsuke; Usami, Atsushi; Miyazawa, Mitsuo

    2015-01-01

    The chemical composition of essential oil extracted from Uncaria Hook ("Chotoko" in Japanese), the branch with curved hook of the herbal medicine Uncaria rhynchophylla has been investigated by GC and GC-MS analyses. Eighty-four compounds, representing 90.8% of the total content was identified in oil obtained from Uncaria Hook. The main components i were (E)-cinnamaldehyde (13.4%), α-copaene (8.0%), methyl eugenol (6.8%), δ-cadinene (5.3%), and curcumene (3.6%). The important key aroma-active compounds in the oil were detected by gas chromatography-olfactometry (GC-O) and aroma extract dilution analysis (AEDA), using the flavor dilution (FD) factor to express the odor potency of each compounds. Furthermore, the odor activity value (OAV) has been used as a measure of the relative contribution of each compound to the aroma of the Uncaria Hook oil. The GC-O and AEDA results showed that α-copaene (FD = 4, OAV = 4376), (E)-linalool oxide (FD = 64, OAV = 9.1), and methyl eugenol (FD = 64, OAV = 29) contributed to the woody and spicy odor of Uncaria Hook oil, whereas furfural (FD = 8, OAV = 4808) contributed to its sweet odor. These results warrant further investigations of the application of essential oil from Uncaria Hook in the phytochemical and medicinal fields.

  17. Purge efficiency in the determination of trihalomethanes in water by purge-and-trap gas chromatography.

    PubMed

    Ruiz-Bevia, Francisco; Fernandez-Torres, Maria J; Blasco-Alemany, Maria P

    2009-01-26

    Purge-and-trap gas chromatography-mass spectrometry (PT-GC-MS) has become an accepted method for the analysis of trihalomethanes (THMs) in water. The purge-and-trap technique is based on an efficient transfer of volatile organic compounds from the liquid (contained in the purge chamber) to the gaseous phase by bubbling with an inert gas. The aim of this work was to study the purge system's efficiency by means of several consecutive purge cycles lasting 11 min each of the same liquid sample. The concentration range chosen of THMs was very wide [5-200 microg L(-1)]. The inert gas flow rate was 40 mL min(-1), and experiments were performed at temperatures of 25, 35 and 50 degrees C. Bromoform (CHBr(3)), the least volatile compound, needed 19 cycles to be purged quantitatively at a concentration of 200 microg L(-1) and only 7 cycles at 5 microg L(-1) for a 25 mL sample at 25 degrees C. Chloroform (CHCl(3)), the most volatile compound, required 4 cycles to be fully extracted at 200 microg L(-1) and 2 at 5 microg L(-1). Finally, Novak's theoretical model, based on the distribution constant between gas and liquid phases, was used to correlate the THMs purging extraction data.

  18. High-performance, static-coated silicon microfabricated columns for gas chromatography.

    PubMed

    Reidy, Shaelah; Lambertus, Gordon; Reece, Jennifer; Sacks, Richard

    2006-04-15

    A procedure is described for the preparation of high-performance etched silicon columns for gas chromatography. Rectangular channels, 150 mum wide by 240 mum deep are fabricated in silicon substrates by gas-phase reactive ion etching. A 0.1-0.2-mum-thick film of dimethyl polysiloxane stationary phase is deposited on the channel walls by filling the channel with a dilute solution in 1:1 n-pentane and dichloromethane and pumping away the solvent. A thermally activated cross-linking agent is used for in situ cross-linking. A 3-m-long microfabricated column generated approximately 12 500 theoretical plates at optimal operating conditions using air as carrier gas. A kinetic model for the efficiency of rectangular cross-section columns is used to evaluate column performance. Results indicate an additional source of gas-phase dispersion beyond longitudinal diffusion and nonequilibrium effects, probably resulting from numerous turns in the gas flow path through the channel. The columns are thermally stable to at least 180 degrees C using air carrier gas. Temperature programming is demonstrated for the boiling point range from n-C5 to n-C12. A 3.0-m-long column heated at 10 degrees C/min obtains a peak capacity of over 100 peaks with a resolution of 1.18 and a separation time of approximately 500 s. With a 0.25-m-long column heated at 30 degrees C/min, a peak capacity of 28 peaks is obtained with a separation time of 150 s. Applications are shown for the analysis of air-phase petroleum hydrocarbons and the high-speed analysis of chemical warfare agent and explosive markers.

  19. Comprehensive two-dimensional gas chromatography for biogas and biomethane analysis.

    PubMed

    Hilaire, F; Basset, E; Bayard, R; Gallardo, M; Thiebaut, D; Vial, J

    2017-09-29

    The gas industry is going to be revolutionized by being able to generate bioenergy from biomass. The production of biomethane - a green substitute of natural gas - is growing in Europe and the United-States of America. Biomethane can be injected into the gas grid or used as fuel for vehicles after compression. Due to various biomass inputs (e.g. agricultural wastes, sludges from sewage treatment plants, etc.), production processes (e.g. anaerobic digestion, municipal solid waste (MSW) landfills), seasonal effects and purification processes (e.g. gas scrubbers, pressure swing adsorption, membranes for biogas upgrading), the composition and quality of biogas and biomethane produced is difficult to assess. All previous publications dealing with biogas analysis reported that hundreds of chemicals from ten chemical families do exist in trace amounts in biogas. However, to the best of our knowledge, no study reported a detailed analysis or the implementation of comprehensive two-dimensional gas chromatography (GC×GC) for biogas matrices. This is the reason why the benefit of implementing two-dimensional gas chromatography for the characterization of biogas and biomethane samples was evaluated. In a first step, a standard mixture of 89 compounds belonging to 10 chemical families, representative of those likely to be found, was used to optimize the analytical method. A set consisting of a non-polar and a polar columns, respectively in the first and the second dimension, was used with a modulation period of six seconds. Applied to ten samples of raw biogas, treated biogas and biomethane collected on 4 industrial sites (two MSW landfills, one anaerobic digester on a wastewater treatment plant and one agricultural biogas plant), this analytical method provided a "fingerprint" of the gases composition at the molecular level in all biogas and biomethane samples. Estimated limits of detection (far below the μgNm(-3)) coupled with the resolution of GC×GC allowed the comparison

  20. The fabrication of all-silicon micro gas chromatography columns using gold diffusion eutectic bonding

    NASA Astrophysics Data System (ADS)

    Radadia, A. D.; Salehi-Khojin, A.; Masel, R. I.; Shannon, M. A.

    2010-01-01

    Temperature programming of gas chromatography (GC) separation columns accelerates the elution rate of chemical species through the column, increasing the speed of analysis, and hence making it a favorable technique to speedup separations in microfabricated GCs (micro-GC). Temperature-programmed separations would be preferred in an all-silicon micro-column compared to a silicon-Pyrex® micro-column given that the thermal conductivity and diffusivity of silicon is 2 orders of magnitude higher than Pyrex®. This paper demonstrates how to fabricate all-silicon micro-columns that can withstand the temperature cycling required for temperature-programmed separations. The columns were sealed using a novel bonding process where they were first bonded using a gold eutectic bond, then annealed at 1100 °C to allow gold diffusion into silicon and form what we call a gold diffusion eutectic bond. The gold diffusion eutectic-bonded micro-columns when examined using scanning electron microscopy (SEM), scanning acoustic microscopy (SAM) and blade insertion techniques showed bonding strength comparable to the previously reported anodic-bonded columns. Gas chromatography-based methane injections were also used as a novel way to investigate proper sealing between channels. A unique methane elution peak at various carrier gas inlet pressures demonstrated the suitability of gold diffusion eutectic-bonded channels as micro-GC columns. The application of gold diffusion eutectic-bonded all-silicon micro-columns to temperature-programmed separations (120 °C min-1) was demonstrated with the near-baseline separation of n-C6 to n-C12 alkanes in 35 s.

  1. Aroma characterization of chinese rice wine by gas chromatography-olfactometry, chemical quantitative analysis, and aroma reconstitution.

    PubMed

    Chen, Shuang; Xu, Yan; Qian, Michael C

    2013-11-27

    The aroma profile of Chinese rice wine was investigated in this study. The volatile compounds in a traditional Chinese rice wine were extracted using Lichrolut EN and further separated by silica gel normal phase chromatography. Seventy-three aroma-active compounds were identified by gas chromatography-olfactometry (GC-O) and gas chromatography-mass spectrometry (GC-MS). In addition to acids, esters, and alcohols, benzaldehyde, vanillin, geosmin, and γ-nonalactone were identified to be potentially important to Chinse rice wine. The concentration of these aroma-active compounds in the Chinese rice wine was further quantitated by combination of four different methods, including headsapce-gas chromatography, solid phase microextraction-gas chromatography (SPME)-GC-MS, solid-phase extraction-GC-MS, and SPME-GC-pulsed flame photometric detection (PFPD). Quantitative results showed that 34 aroma compounds were at concentrations higher than their corresponding odor thresholds. On the basis of the odor activity values (OAVs), vanillin, dimethyl trisulfide, β-phenylethyl alcohol, guaiacol, geosmin, and benzaldehyde could be responsible for the unique aroma of Chinese rice wine. An aroma reconstitution model prepared by mixing 34 aroma compounds with OAVs > 1 in an odorless Chinese rice wine matrix showed a good similarity to the aroma of the original Chinese rice wine.

  2. Absorbents as packing materials in on-line coupling of reversed phase liquid chromatography and gas chromatography via a programmed temperature vaporizer.

    PubMed

    Flores, Gema; Ruiz Del Castillo, Maria Luisa; Herraiz, Marta

    2007-06-15

    A method based on the use of absorbents as packing materials in the interface of the direct coupling between reversed phase liquid chromatography and gas chromatography (RPLC-GC) is proposed. To that end, a comparative study on different adsorbents and absorbents was carried out. Specifically, Tenax TA and Gaschrom were used as adsorbents while polydimethylsiloxane and poly(50% phenyl:50% methylsiloxane) were the absorbents tested. Some experimental variables involved in the solvent elimination were separately optimised for adsorbent and absorbent materials. Relative standard deviations (RSD) lower than 10% were achieved in all cases but the use of absorbents showed interesting advantages with respect to adsorbents, namely a simpler performance of the experimental work, which facilitates the sample preparation step and the subsequent gas chromatographic analysis to be performed.

  3. Identification of Gibberellins in Norway Spruce (Picea abies [L.] Karst.) by Combined Gas Chromatography-Mass Spectrometry

    PubMed Central

    Odén, Per Christer; Schwenen, Ludger; Graebe, Jan E.

    1987-01-01

    Gibberellins A1 (GA1), A3 and A9 were identified from extracts of shoots of 6-month old Norway spruce (Picea abies) seedlings by the use of sequential reverse and normal phase high performance liquid chromatography (HPLC), bioassay, radioimmunoassay (RIA) and combined gas chromatography-mass spectrometry (GC-MS). The bioassay and RIA were used after fractionation by HPLC to detect the GA-containing fractions, which were then examined by GC-MS. The GAs identified are considered to be endogenous. PMID:16665471

  4. Analysis of the venom of the Sydney funnel-web spider, Atrax robustus using gas chromatography mass spectrometry.

    PubMed

    Duffield, P H; Duffield, A M; Carroll, P R; Morgans, D

    1979-03-01

    Thirteen compounds have been identified using gas chromatography mass spectrometry in the venom of the Sydney funnel-web spider, Atrax robustus. The compounds were identified as their trimethylsilyl or pentafluoropropionate derivatives and were citric acid, lactic acid, phosphoric acid, glycerol, urea, glucose, gamma-aminobutyric acid, glycine, spermidine, spermine, tyramine and octopamine. Female venom contained trace quantities of 5-methyoxytryptamine which was not detected in male venom. Quantitative determination of tyramine and octopamine was achieved using chemical ionization (CH4) gas chromatography mass spectrometry and deuterated internal standards.

  5. Mass Spectral Studies of 1-(2-Chloroethoxy)-2-[(2-chloroethyl)thio] Ethane and Related Compounds Using Gas ChromatographyMass Spectrometry and Gas ChromatographyTriple-Quadrupole Mass Spectrometry

    DTIC Science & Technology

    2016-02-01

    Capillary Column Gas Chromatography/Tandem Mass Spectrometry Verification of Chemical Warfare Agents. Rapid Commun . Mass Spectrom. 1992, 6, 717...Applications; American Chemical Society : Washington, DC, 2001. 23. Gross, J.H. Mass Spectrometry; Springer-Verlag: Berlin, 2002. 24. Madsen, J.Ø.; Nolde, C... MASS SPECTRAL STUDIES OF 1-(2-CHLOROETHOXY)-2-[(2-CHLOROETHYL)THIO] ETHANE AND RELATED COMPOUNDS USING GAS

  6. Evaluation of crystallization behavior on the surface of nifedipine solid dispersion powder using inverse gas chromatography.

    PubMed

    Miyanishi, Hideo; Nemoto, Takayuki; Mizuno, Masayasu; Mimura, Hisashi; Kitamura, Satoshi; Iwao, Yasunori; Noguchi, Shuji; Itai, Shigeru

    2013-02-01

    To investigate crystallization behavior on the surface of amorphous solid dispersion powder using inverse gas chromatography (IGC) and to predict the physical stability at temperatures below the glass transition temperature (T (g)). Amorphous solid dispersion powder was prepared by melt-quenching of a mixture of crystalline nifedipine and polyvinylpyrrolidon (PVP) K-30. IGC was conducted by injecting undecane (probe gas) and methane (reference gas) repeatedly to the solid dispersion at temperatures below T (g). Surface crystallization was evaluated by the retention volume change of undecane based on the observation that the surface of the solid dispersion with crystallized nifedipine gives an increased retention volume. On applying the retention volume change to the Hancock-Sharp equation, surface crystallization was found to follow a two-dimensional growth of nuclei mechanism. Estimation of the crystallization rates at temperatures far below T (g) using the Avrami-Erofeev equation and Arrhenius equation showed that, to maintain its quality for at least three years, the solid dispersion should be stored at -20°C (T (g) - 65°C). IGC can be used to evaluate crystallization behavior on the surface of a solid dispersion powder, and, unlike traditional techniques, can also predict the stability of the solid dispersion based on the surface crystallization behavior.

  7. Aircraft measurements of nitrogen dioxide and peroxyacyl nitrates using luminol chemiluminescence with fast capillary gas chromatography

    SciTech Connect

    Gaffney, J.S.; Marley, N.A.; Drayton, P.J.

    1997-09-01

    Peroxyacyl nitrates (PANs) and nitrogen dioxide (NO{sub 2}) are important trace gas species associated with photochemical air pollution. The PANs are in thermal equilibrium with the peroxyacetyl radical and NO{sub 2}. Because PANs are trapped peroxy radicals, they are an important indicator species of the photochemical age of an air parcel, as well as being a means of long-range transporting of NO{sub 2}, leading to the formation of regional ozone and other oxidants. Typically, PANs are measured by using a gas chromatograph with electron-capture detection (ECD). Once automated, this method has been shown to be reliable and quite sensitive, allowing the levels of PANs to be measured at low parts per trillion in the troposphere. Unfortunately, a number of other atmospheric gases also have strong ECD signals or act as inferences and limit the speed in which the analysis can be completed. Currently, the shortest analysis time for PAN is approx. 5 minutes with ECD. The authors recent examined the luminol detection of NO{sub 2} and PANs using gas capillary chromatography for rapid monitoring of these important trace gases. Analysis of the PANs (PAN, PPN, and PBN) and NO{sub 2} in one minute has been demonstrated in laboratory studies by using this approach. Reported here are modifications of this instrument for aircraft operation and preliminary results from test flights taken near Pasco, Washington in August of 1997.

  8. Determination of residual epichlorohydrin in sevelamer hydrochloride by static headspace gas chromatography with flame ionization detection.

    PubMed

    Karthikeyan, Kaliaperumal; Arularasu, Govindasamy T; Devaraj, Perumalsamy; Pillai, Karnam Chandrasekara

    2010-01-01

    A sensitive static headspace gas chromatographic method was developed and validated for the determination of residual epichlorohydrin (ECH) in sevelamer hydrochloride (SVH) drug substance. This method utilized a Phenomenex Zebron ZB-WAX GC column, helium as carrier gas with flame ionization detection. The critical experimental parameters, such as, headspace vial incubation time and incubation temperature were studied and optimized. The method was validated as per United States Pharmacopoeia (USP) and International Conference on Harmonization (ICH) guidelines in terms of detection limit (DL), quantitation limit (QL), linearity, precision, accuracy, specificity and robustness. A linear range from 0.30 to 10 Îg/mL was obtained with the coefficient of determination (r(2)) 0.999. The DL and QL of ECH were 0.09 Îg/mL and 0.30 Îg/mL, respectively. The recovery obtained for ECH was between 91.7 and 96.6%. Also, the specificity of the method was proved through gas chromatography mass spectrometry (GC-MS). This method was applied successfully to determine the content of residual ECH in SVH bulk drug.

  9. Development of a compact and simple gas chromatography for oral malodor measurement.

    PubMed

    Murata, Takatoshi; Rahardjo, Anton; Fujiyama, Yuki; Yamaga, Takayuki; Hanada, Mariko; Yaegaki, Ken; Miyazaki, Hideo

    2006-07-01

    Volatile sulfur compounds (VSCs) in oral air are the only type of gases correlated with the strength of oral malodor. We developed a compact and simple gas chromatograph (GC) equipped with a newly invented indium oxide semiconductor gas sensor (SCS) for measuring the concentrations of VSCs in mouth air. We have assessed the correlation between measurements with a GC-SCS and those with a regular GC. Oral air samples from randomly selected volunteers were analyzed with both a GC-SCS and a GC with a flame photometric detector (FPD), which is specific to VSCs, and GC-SCS measurements were compared to those obtained by GC-FPD. Subsequently, oral air samples before and after mouthrinsing with 5% ethanol mouthwash were analyzed to determine the effect of ethanol on VSC measurements by GC-SCS. There were strong correlations between VSC concentrations determined using these two gas chromatography methods (hydrogen sulfide, R=0.821, P<0.0001; methyl mercaptan, R=0.870, P<0.0001; and dimethyl sulfide, R=0.770, P<0.0001). Although GC-SCS can differentiate ethanol and VSCs in oral air samples after mouthrinsing, GC-SCS measurements demonstrated higher values than those obtained by GC-FPD; however, this discrepancy improved over time due to the reduced effect of ethanol. The results suggest that GC-SCS may be useful for the diagnosis of halitosis.

  10. Metal Nanoparticles Protected with Monolayers: Applications for Chemical Vapor Sensing and Gas Chromatography

    SciTech Connect

    Grate, Jay W.; Nelson, David A.; Skaggs, Rhonda L.; Synovec, Robert E.; Gross, Gwen M.

    2004-03-31

    Nanoparticles and nanoparticle-based materials are of considerable interest for their unique properties and their potential for use in a variety of applications. Metal nanoparticles, in which each particle’s surface is coated with a protective organic monolayer, are of particular interest because the surface monolayer stabilizes them relative to aggregation and they can be taken up into solutions.(1-4) As a result they can be processed into thin films for device applications. We will refer to these materials as monolayer-protected nanoparticles, or MPNs. Typically the metal is gold, the organic layer is a self-assembled thiol layer, and this composition will be assumed throughout the remainder of this chapter. A diversity of materials and properties is readily accessible by straightforward synthetic procedures, either by the structures of the monolayer-forming thiols used in the synthesis or by post-synthetic modifications of the monolayers. A particularly promising application for these materials is as selective layers on chemical vapor sensors. In this role, the thin film of MPNs on the device surface serves to collect and concentrate gas molecules at the sensor’s surface. Their sorptive properties also lend them to use as new nanostructured gas chromatographic stationary phases. This chapter will focus on the sorptive properties of MPNs as they relate to chemical sensors and gas chromatography.

  11. Determination of Residual Epichlorohydrin in Sevelamer Hydrochloride by Static Headspace Gas Chromatography with Flame Ionization Detection

    PubMed Central

    Karthikeyan, Kaliaperumal; Arularasu, Govindasamy T.; Devaraj, Perumalsamy; Pillai, Karnam Chandrasekara

    2010-01-01

    A sensitive static headspace gas chromatographic method was developed and validated for the determination of residual epichlorohydrin (ECH) in sevelamer hydrochloride (SVH) drug substance. This method utilized a Phenomenex Zebron ZB-WAX GC column, helium as carrier gas with flame ionization detection. The critical experimental parameters, such as, headspace vial incubation time and incubation temperature were studied and optimized. The method was validated as per United States Pharmacopoeia (USP) and International Conference on Harmonization (ICH) guidelines in terms of detection limit (DL), quantitation limit (QL), linearity, precision, accuracy, specificity and robustness. A linear range from 0.30 to 10 μg/mL was obtained with the coefficient of determination (r2) 0.999. The DL and QL of ECH were 0.09 μg/mL and 0.30 μg/mL, respectively. The recovery obtained for ECH was between 91.7 and 96.6%. Also, the specificity of the method was proved through gas chromatography mass spectrometry (GC-MS). This method was applied successfully to determine the content of residual ECH in SVH bulk drug. PMID:21179319

  12. On-column micro gas chromatography detection with capillary-based optical ring resonators.

    PubMed

    Shopova, Siyka I; White, Ian M; Sun, Yuze; Zhu, Hongying; Fan, Xudong; Frye-Mason, Greg; Thompson, Aaron; Ja, Shiou-jyh

    2008-03-15

    We developed a novel on-column micro gas chromatography (microGC) detector using capillary based optical ring resonators (CBORRs). The CBORR is a thin-walled fused silica capillary with an inner diameter ranging from a few tens to a few hundreds of micrometers. The interior surface of the CBORR is coated with a layer of stationary phase for gas separation. The circular cross section of the CBORR forms a ring resonator and supports whispering gallery modes (WGMs) that circulate along the ring resonator circumference hundreds of times. The evanescent field extends into the core and is sensitive to the refractive index change induced by the interaction between the gas sample and the stationary phase. The WGM can be excited and monitored at any location along the CBORR by placing a tapered optical fiber against the CBORR, thus enabling on-column real-time detection. Rapid separation of both polar and nonpolar samples was demonstrated with subsecond detection speed. Theoretical work was also established to explain the CBORR detection mechanism. While low-nanogram detection limits are observed in these preliminary tests, many methods for improvements are under investigation. The CBORR is directly compatible with traditional capillary GC columns without any dead volumes. Therefore, the CBORR-based muGC is a very promising technology platform for rapid, sensitive, and portable analytical devices.

  13. Resolution of diacylglycerol moieties of natural glycerophospholipids by gas-liquid chromatography on polar capillary columns.

    PubMed

    Myher, J J; Kuksis, A

    1982-06-01

    A rapid and practical method has been developed for the gas-liquid chromatographic determination of the sn-1,2-diacylglycerol moieties of natural glycerophospholipids using polar wall-coated open tubular columns. The method gives complete resolution and quantitative estimates for all species according to molecular weight and degree of unsaturation, including stearoyl docosahexaenoylglycerol and related polyunsaturates. For this purpose the sn-1,2-diacylglycerols are obtained from the glycerophospholipids by hydrolysis with phospholipase C and are converted into the trimethylsilyl or tertiary-butyldimethylsilyl ethers. The silyl ethers are separated by gas-liquid chromatography on the capillary glass columns coated with a polar cyanopropylsiloxane polymer, in the temperature range 175-250 degrees C, using hydrogen as the carrier gas. Practical applications of the method are illustrated by analyses of the sn-1,2-diacylglycerol moieties of the phosphatidylcholines of soybean phosphatides, egg yolk, and rat liver. The method of analysis is applicable to other classes of glycerophospholipids and the total time requirements for the analysis of any one phospholipid class are comparable to those for a fatty acid analysis.

  14. GLOBAL PEAK ALIGNMENT FOR COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY MASS SPECTROMETRY USING POINT MATCHING ALGORITHMS

    PubMed Central

    Deng, Beichuan; Kim, Seongho; Li, Hengguang; Heath, Elisabeth; Zhang, Xiang

    2016-01-01

    Comprehensive two-dimensional gas chromatography coupled with mass spectrometry (GC×GC-MS) has been used to analyze multiple samples in a metabolomics study. However, due to some uncontrollable experimental conditions, such as the differences in temperature or pressure, matrix effects on samples, and stationary phase degradation, there is always a shift of retention times in the two GC columns between samples. In order to correct the retention time shifts in GC×GC-MS, the peak alignment is a crucial data analysis step to recognize the peaks generated by the same metabolite in different samples. Two approaches have been developed for GC×GC-MS data alignment: profile alignment and peak matching alignment. However, these existing alignment methods are all based on a local alignment, resulting that a peak may not be correctly aligned in a dense chromatographic region where many peaks are present in a small region. False alignment will result in false discovery in the downstream statistical analysis. We, therefore, develop a global comparison based peak alignment method using point matching algorithm (PMA-PA) for both homogeneous and heterogeneous data. The developed algorithm PMA-PA first extracts feature points (peaks) in the chromatography and then searches globally the matching peaks in the consecutive chromatography by adopting the projection of rigid and non-rigid transformation. PMA-PA is further applied to two real experimental data sets, showing that PMA-PA is a promising peak alignment algorithm for both homogenous and heterogeneous data in terms of F1 score, although it uses only peak location information. PMID:27650662

  15. Comparison of gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry with electron ionization for determination of N-nitrosamines in environmental water.

    PubMed

    Chen, Wenwen; Li, Xiaoshui; Huang, Huanfang; Zhu, Xuetao; Jiang, Xiaoyu; Zhang, Yuan; Cen, Kuang; Zhao, Lunshan; Liu, Xiuli; Qi, Shihua

    2017-02-01

    N-nitrosamines are trace organic contaminants of environmental concern when present in groundwater and river water due to their potent carcinogenicity. Therefore, N-nitrosamine analysis is increasingly in demand. Gas chromatography-mass spectrometry (GC-MS) and GC-tandem mass spectrometry (GC-MS/MS), both with electron ionization (EI), were compared for analysis of nine N-nitrosamines extracted from environmental water matrices. A total of 20 fishpond water, river water, and groundwater samples from Sihui and Shunde, China were collected for a survey of N-nitrosamine concentrations in real water samples. Various solid-phase extraction (SPE) conditions and GC conditions were first examined for the pre-concentration and separation steps. The analysis of N-nitrosamines in environmental waters demonstrated that their quantification with GC-MS poses a challenge due to the occurrence of co-eluting interferences. Conversely, the use of GC-MS/MS increased selectivity because of the fragmentation generated from precursor ions in the 'multiple reaction monitoring' (MRM) mode, which is expected to extract target analytes from the environmental water matrix. Thus, the high performance of GC-MS/MS with EI was used to quantify nine N-nitrosamines in environmental waters with detection limits of 1.1-3.1 ng L(-1). N-nitrosodimethylamine (NDMA) concentrations were in the range of N.D. to 258 ng L(-1). Furthermore, other N-nitrosamines, except N-nitrosomethylethylamine (NMEA), N-nitroso-di-n-propylamine (NDPA) and N-nitrosopiperidine (NPIP), were also detected. Our findings suggest that GC-MS/MS with EI would be widely applicable in identifying N-nitrosamines in environmental waters and can be used for routine monitoring of these chemicals.

  16. Qualitative analysis of Copaifera oleoresin using comprehensive two-dimensional gas chromatography and gas chromatography with classical and cold electron ionisation mass spectrometry.

    PubMed

    Wong, Yong Foo; Uekane, Thais M; Rezende, Claudia M; Bizzo, Humberto R; Marriott, Philip J

    2016-12-16

    Improved separation of both sesquiterpenes and diterpenic acids in Copaifera multijuga Hayne oleoresin, is demonstrated by using comprehensive two-dimensional gas chromatography (GC×GC) coupled to accurate mass time-of-flight mass spectrometry (accTOFMS). GC×GC separation employs polar phases (including ionic liquid phases) as the first dimension ((1)D) column, combined with a lower polarity (2)D phase. Elution temperatures (Te) of diterpenic acids (in methyl ester form, DAME) increased as the (1)D McReynolds' polarity value of the column phase decreased. Since Te of sesquiterpene hydrocarbons decreased with increased polarity, the very polar SLB-IL111 (1)D phase leads to excessive peak broadening in the (2)D apolar phase due to increased second dimension retention ((2)tR). The combination of SLB-IL59 with a nonpolar column phase was selected, providing reasonable separation and low Te for sesquiterpenes and DAME, compared to other tested column sets, without excessive (2)tR. Identities of DAME were aided by both soft (30eV) electron ionisation (EI) accurate mass TOFMS analysis and supersonic molecular beam ionisation (cold EI) TOFMS, both which providing less fragmentation and increased relative abundance of molecular ions. The inter-relation between EI energies, emission current, signal-to-noise and mass error for the accurate mass measurement of DAME are reported. These approaches can be used as a basis for conducting of GC×GC with soft EI accurate mass measurement of terpenes, particularly for unknown phytochemicals. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Simultaneous characterization of methane and carbon dioxide produced by cultured methanogens using gas chromatography/isotope ratio mass spectrometry and gas chromatography/mass spectrometry.

    PubMed

    Ai, Guomin; Zhu, Jinxing; Dong, Xiuzhu; Sun, Tong

    2013-09-15

    The stable carbon isotope ratios of methanogen-produced CH4 and CO2 are useful information for identifying and quantifying methanogenic pathways. Isotope ratio mass spectrometry combined with gas chromatography (GC/IRMS) is a very attractive tool for performing high-precision compound-specific isotope analysis. However, no GC/IRMS techniques have yet been available or been validated that give baseline separation of methanogen-produced CH4 and CO2 from N2/N-oxides and H2O vapor at ambient temperature and compatibility with analysis by mass spectrometry. Microbe-produced CH4 and CO2 in headspace gases were separated from N2/N-oxides and H2O vapor in a single run on a GS-CarbonPLOT column at 35°C and with a maximum operating temperature of 120-140°C. The simultaneous characterization of CH4 and CO2 was then performed by GC/IRMS using an optimized backflush time to eliminate the interference from N2/N-oxides and H2O vapor, and by GC/MS due to there being no interference from O2 gas in the culture. GC/MS and GC/IRMS were used to calculate the ionization efficiency of CO2 as 8.22-8.84 times that of CH4 in GC/MS analysis, and it was deduced that the N-oxides, which can potentially interfere with δ(13)C analysis, were probably produced mainly in the source of the isotope ratio mass spectrometer. We also determined the aceticlastic methanogenic pathway. The established GC/MS and GC/IRMS techniques are suitable for characterizing the gaseous carbon-containing compounds produced by microbial cultures. Through high-precision carbon isotope analysis by GC/IRMS combined with low concentrations of (13)C-labelled substrates, the technique has great potential for identifying and quantifying methanogen-mediated carbon metabolic processes and pathways. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Simultaneous analysis of polychlorinated biphenyls and organochlorine pesticides in seawater samples by membrane-assisted solvent extraction combined with gas chromatography-electron capture detector and gas chromatography-tandem mass spectrometry.

    PubMed

    Shi, Xizhi; Tang, Zigang; Sun, Aili; Zhou, Lei; Zhao, Jian; Li, Dexiang; Chen, Jiong; Pan, Daodong

    2014-12-01

    A highly efficient and environment-friendly membrane-assisted solvent extraction system combined with gas chromatography-electron capture detector was applied in the simultaneous determination of 17 polychlorinated biphenyls and organochlorine pesticides in seawater samples. Variables affecting extraction efficiency, including extraction solvent used, stirring rate, extraction time, and temperature, were optimized extensively. Under optimal extraction conditions, recoveries between 76.9% and 104.6% in seawater samples were achieved, and relative standard deviation values below 10% were obtained. The limit of detection (signal-to-noise ratio=3) and limit of quantification (signal-to-noise ratio=10) of 17 polychlorinated biphenyls and organochlorine pesticides in seawater ranged from 0.14ngL(-1) to 0.36ngL(-1) and 0.46ngL(-1) to 1.19ngL(-1), respectively. Matrix effects on extraction efficiency were evaluated by comparing with the results obtained using tap water. The extraction effect of developed membrane-assisted solvent extraction method was further demonstrated by gas chromatography-tandem mass spectrometry which can provide structural information of the analytes for more accurate identification, and results identical to those produced by gas chromatography-electron capture detector were obtained. These findings demonstrate the applicability of the developed membrane-assisted solvent extraction determination method for coupling to gas chromatography-electron capture detector or tandem mass spectrometry for determining polychlorinated biphenyls and organochlorine pesticides in seawater samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Migrating components in a polyurethane laminating adhesive identified using gas chromatography/mass spectrometry.

    PubMed

    Athenstädt, Behnusch; Fünfrocken, Michael; Schmidt, Torsten C

    2012-08-30

    Plastics are increasingly used as packaging materials for pharmaceuticals. However, diffusion of compounds in plastic into drugs may endanger patients' health. Regulatory authorities therefore demand detailed information about leachable compounds in plastics. Here we identify migrating components of a sterilization-resistant polyurethane (PUR) adhesive used in the primary packaging for an aqueous pharmaceutical. This identification is an essential first step for quantification and toxicological evaluation of the compounds. We used various hyphenated mass spectrometry (MS) methods: gas chromatography (GC/MS) with either electron impact ionization or chemical ionization, and high resolution liquid chromatography (LC/MS) with electrospray ionization. Of the 13 migrating substances detected, 11 are cyclic esters with characteristic fragmentation schemes apparent from their mass spectra. These esters are formed as by-products during the reaction of adipic and isophthalic acid with monoethylene glycol and diethyelene glycol. A cyclic ester of isophthalic acid and tetraethylene glycol and a product of the reaction of isophoron diisocyanate with methanol were clearly identified. Complementary use of several hyphenated mass spectrometric methods enables successful identification of leachable compounds in the PUR adhesive under study. This opens the way for quantification and evaluation of the potential toxicities of these compounds. Despite the range of compositions of PUR laminates, the approach presented here may be applicable for the qualitative assessment of all PURs. Copyright © 2012 John Wiley & Sons, Ltd.

  20. High resolution capillary column development for selective separations in gas chromatography

    SciTech Connect

    Przybyciel, M.

    1985-01-01

    A review of techniques for the preparation of high resolution capillary columns for gas chromatography is presented. Surface roughing, surface deactivation, stationary phase coating, and stationary phase crosslinking are discussed. Criteria for the selection of GC stationary phases and procedures for column evaluation are presented. A method is proposed for the isolation and determination of crude oil contamination in tropical plants and sediments. The method uses Florisil (TM) chromatography for the simultaneous clean-up and fractionation of aliphatic and aromatic hydrocarbons. Crosslinked SE-54 fused silica capillary columns prepared in our laboratory were employed for all GC separations. Mass spectrometry was used to help locate and identify specific oil components despite the intense background of the chromatogram. Crude oil components were identified in extracts of mangrove plant samples collected from the Peck Slip oil spill site at Media Munda, Puerto Rico. Crude oil components were also identified in sediment samples from controlled oil spill of Prudhoe Bay oil at Laguna de Chiriqui, Panama.

  1. Fingerprint developing of coffee flavor by gas chromatography-mass spectrometry and combined chemometrics methods.

    PubMed

    Huang, Lan-Fang; Wu, Ming-Jian; Zhong, Ke-Jun; Sun, Xian-Jun; Liang, Yi-Zeng; Dai, Yun-Hui; Huang, Ke-Long; Guo, Fang-Qiu

    2007-04-11

    In this paper, chromatographic fingerprint was firstly used for quality control of tobacco flavors. Based on gas chromatography-mass spectrometry (GC-MS) and combined chemometrics methods, a simple, reliable and reproducible method for developing chromatographic fingerprint of coffee flavor, one of tobacco flavors, was described. Six coffee flavor samples obtained from different locations were used to establish the fingerprint. The qualitative and quantitative analysis of coffee flavor sample from Shenzhen was completed with the help of subwindow factor analysis (SFA). Fifty-two components of 68 separated constituents in coffee flavor sample from Shenzhen, accounting for 88.42% of the total content, were identified and quantified. Then, spectral correlative chromatography (SCC) was used to extract the common peaks from other five studied coffee flavor samples. Thirty-eight components were found to exist in all six samples. Finally, the method validation of fingerprint analysis was performed based on the relative retention time and the relative peak area of common peaks, sample stability and similarity analysis. The similarities of six coffee flavor samples were more than 0.9104 and showed that samples from different locations were consistent to some extent. The developed chromatographic fingerprint was successfully used to differentiate coffee flavor from cocoa flavor and some little difference sample prepared with coffee flavor and cocoa flavor by both similarity comparison and principal component projection analysis. The developed method can be used for quality control of coffee flavor.

  2. Comprehensive two-dimensional gas chromatography-mass spectrometry: a review.

    PubMed

    Mondello, Luigi; Tranchida, Peter Quinto; Dugo, Paola; Dugo, Giovanni

    2008-01-01

    Although comprehensive two-dimensional gas chromatography (GC x GC) has been on the scene for more than 15 years, it is still generally considered a relatively novel technique and is yet far from being fully established. The revolutionary aspect of GC x GC, with respect to classical multidimensional chromatography, is that the entire sample is subjected to two distinct analytical separations. The resulting enhanced separating capacity makes this approach a prime choice when GC analysts are challenged with highly complex mixtures. The combination of a third mass spectrometric dimension to a GC x GC system generates the most powerful analytical tool today for volatile and semi-volatile analytes. The present review is focused on the rather brief, but not scant, history of comprehensive two-dimensional GC-MS: the first experiments were carried out at the end of the 1990s and, since then, the methodology has been increasingly studied and applied. Almost all GC x GC-MS applications have been carried out by using either a time-of-flight or quadrupole mass analyzer; significant experiments relative to a variety of research fields, as well as advantages and disadvantages of the MS systems employed, are discussed. The principles, practical and theoretical aspects, and the most significant developments of GC x GC are also described. (c) 2008 Wiley Periodicals, Inc.

  3. Issues pertaining to the analysis of buprenorphine and its metabolites by gas chromatography-mass spectrometry.

    PubMed

    Wang, Yu-Shan; Lin, Dong-Liang; Yang, Shu-Ching; Wu, Meng-Yan; Liu, Ray H; Su, Lien-Wen; Cheng, Pai-Sheng; Liu, Chiareiy; Fuh, Ming-Ren

    2010-03-05

    "Substitution therapy" and the use of buprenorphine (B) as an agent for treating heroin addiction continue to gain acceptance and have recently been implemented in Taiwan. Mature and widely utilized gas chromatography-mass spectrometry (GC-MS) technology can complement the low cost and highly sensitive immunoassay (IA) approach to facilitate the implementation of analytical tasks supporting compliance monitoring and pharmacokinetic/pharmacogenetic studies. Issues critical to GC-MS analysis of B and norbuprenorphine (NB) (free and as glucuronides), including extraction, hydrolysis, derivatization, and quantitation approaches were studied, followed by comparing the resulting data against those derived from IA and two types of liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. Commercial solid-phase extraction devices, highly effective for recovering all metabolites, may not be suitable for the analysis of free B and NB; acetyl-derivatization products exhibit the most favorable chromatographic, ion intensity, and cross-contribution characteristics for GC-MS analysis. Evaluation of IA, GC-MS, and LC-MS/MS data obtained in three laboratories has proven the 2-aliquot GC-MS protocol effective for the determination of free B and NB and their glucuronides.

  4. Measurement of F2- isoprostanes and isofurans using gas chromatography-mass spectrometry.

    PubMed

    Milne, Ginger L; Gao, Benlian; Terry, Erin S; Zackert, William E; Sanchez, Stephanie C

    2013-06-01

    F2-Isoprostanes (IsoPs) are isomers of prostaglandin F2α formed from the nonenzymatic free radical-catalyzed peroxidation of arachidonic acid. Since discovery of these molecules by Morrow and Roberts in 1990, F2-IsoPs have been shown to be excellent biomarkers as well as potent mediators of oxidative stress in vivo in humans. Isofurans (IsoFs) are also oxidation products generated from the nonenzymatic oxidation of arachidonic acid. IsoFs are preferentially formed instead of F2-IsoPs in settings of increased oxygen tension. The protocol presented herein is the current methodology that our laboratory uses to quantify F2-IsoPs and IsoFs in biological tissues and fluids using gas chromatography/mass spectrometry (GC/MS). A variety of analytical procedures to measure F2-IsoPs, including other GC/MS methods and liquid chromatography/MS and immunological approaches, are reported in the literature. This method provides a very low limit of quantitation and is suitable for analysis of both F2-IsoPs and IsoFs from a variety of biological sources including urine, plasma, tissues, cerebral spinal fluid, exhaled breath condensate, and amniotic fluid, among others.

  5. A micro gas chromatography column with a micro thermal conductivity detector for volatile organic compound analysis.

    PubMed

    Sun, J H; Cui, D F; Chen, X; Zhang, L L; Cai, H Y; Li, H

    2013-02-01

    In this paper, a micro gas chromatography (μGC) system contained a μGC column and a micro thermal conductivity detector (μTCD) was proposed. In order to reduce the volume of the system, some micro heaters were integrated on the surface and backside of the GC column, which could provide a robust temperature programming capability and rapidly increase the temperature of the μGC column. In addition, a silicon-glass μTCD with four-thermistor thermal conductivity cells that can offer significant advantages over previously reported designs including low dead volume, good thermal isolation, and elimination of the thermal noise was proposed in this paper. Experimental results have indicated that the μGC system with a detection limit of several ppm concentration levels separated and detected the benzene, toluene, and styrene in less than 3 min, and the μGC system also exhibited a good linear response in the test range.

  6. Use of inverse gas chromatography to account for the pervaporation performance in the microemulsion breakdown.

    PubMed

    Hadj-Ziane, Amel; Moulay, Saâd; Canselier, Jean Paul

    2005-10-14

    Mass transfer phenomenon that occurs in the pervaporation process when applied to the microemulsion breakdown, was confirmed by the results of inverse gas chromatography. The stationary phase for this study was polydimethylsiloxane (PDMS), a hydrophobic polymer employed as a membrane in the pervaporation technique. The retention times of the different molecule probes (toluene, cyclohexane, and n-butanol) gave an insight into the extent of the interactions between each of these molecules and the stationary phase; these molecules were the components of the two microemulsions in study. The infinite dilution conditions allowed to determine the thermodynamic and the chromatographic parameters gamma(infinity) (the infinite dilution activity coefficient), the Flory-Huggins parameter interactions X12(infinity), and Vg(0) (the specific retention volume), respectively. The magnitudes of the latter parameters threw some light on the permselectivity of the membrane in the pervaporation operation.

  7. Rapid quantification of dimethyl methylphosphonate from activated carbon particles by static headspace gas chromatography mass spectrometry.

    PubMed

    Mitchell, Brendan L; Billingsley, Brit G; Logue, Brian A

    2013-06-07

    Activated carbon (AC) particles are utilized as an adsorbent for binding hazardous vapors in protective equipment. The binding affinity and utilization of these AC particles should be known to ensure effective and efficient use. Therefore, a simple and effective method was developed for the quantification of the chemical warfare agent simulant, dimethyl methylphosphonate (DMMP), from AC particles. Static headspace gas chromatography mass-spectrometry with internal standard, DMMP-d6, was used to perform the analysis. The method produced a linear dynamic range of 2.48-620g DMMP/kg carbon and a detection limit of 1.24g DMMP/kg carbon. Furthermore, the method produced a coefficient of variation of less than 16% for all intra- and inter-assay analyses. The method provided a simple and effective procedure for quantifying DMMP from AC particles and was applied to the analysis of a DMMP-exposed AC protective respirator filter.

  8. Determination of selected fatty acids in dried sweat spot using gas chromatography with flame ionization detection.

    PubMed

    Kanďár, Roman; Drábková, Petra; Andrlová, Lenka; Kostelník, Adam; Čegan, Alexander

    2016-11-01

    A method is described for the determination of fatty acids in dried sweat spot and plasma samples using gas chromatography with flame ionization detection. Plasma and dried sweat spot samples were obtained from a group of blood donors. The sweat was collected from each volunteer during exercise. Sweat was spotted onto collection paper containing butylated hydroxytoluene. Fatty acids were derivatized with acetyl chloride in methanol to form methyl esters of fatty acids. The fatty acids in dried sweat spot samples treated with butylated hydroxytoluene and stored at -20°C were stable for 3 months. Our results indicate that sweat contains, among fatty acids with short chain, also fatty acids with long chain and unsaturated fatty acids. Linear relationships between percentage content of selected fatty acids in dried sweat spot and plasma were observed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Discrimination of honeys using colorimetric sensor arrays, sensory analysis and gas chromatography techniques.

    PubMed

    Tahir, Haroon Elrasheid; Xiaobo, Zou; Xiaowei, Huang; Jiyong, Shi; Mariod, Abdalbasit Adam

    2016-09-01

    Aroma profiles of six honey varieties of different botanical origins were investigated using colorimetric sensor array, gas chromatography-mass spectrometry (GC-MS) and descriptive sensory analysis. Fifty-eight aroma compounds were identified, including 2 norisoprenoids, 5 hydrocarbons, 4 terpenes, 6 phenols, 7 ketones, 9 acids, 12 aldehydes and 13 alcohols. Twenty abundant or active compounds were chosen as key compounds to characterize honey aroma. Discrimination of the honeys was subsequently implemented using multivariate analysis, including hierarchical clustering analysis (HCA) and principal component analysis (PCA). Honeys of the same botanical origin were grouped together in the PCA score plot and HCA dendrogram. SPME-GC/MS and colorimetric sensor array were able to discriminate the honeys effectively with the advantages of being rapid, simple and low-cost. Moreover, partial least squares regression (PLSR) was applied to indicate the relationship between sensory descriptors and aroma compounds. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry.

    PubMed

    Robbat, Albert; Considine, Thomas; Antle, Patrick M

    2010-09-01

    This paper describes analysis of environmental pollutants at depth without bringing sample to the surface. It is based on an improved 3-stage Peltier freeze trap, which efficiently pre-concentrates volatile coal tar and petroleum hydrocarbons, and an integrated system for detecting pollutants on-line, in real-time by photoionization detection and quantitation by gas chromatography/mass spectrometry (GC/MS) as the probe is advanced into the subsurface. Findings indicate measurement precision and accuracy for volatiles meet EPA criteria for hazardous waste site investigations. When a Teflon membrane inlet is used to detect contaminants in groundwater, its 140 degrees C temperature limit restricts analyte collection in soil to C(2)-phenanthrenes. Two case studies demonstrate the probe is well-suited to tracking petroleum and coal tar plumes from source to groundwater. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  11. Rapid determination of moisture content in paper materials by multiple headspace extraction gas chromatography.

    PubMed

    Xie, Wei-Qi; Chai, Xin-Sheng

    2016-04-22

    This paper describes a new method for the rapid determination of the moisture content in paper materials. The method is based on multiple headspace extraction gas chromatography (MHE-GC) at a temperature above the boiling point of water, from which an integrated water loss from the tested sample due to evaporation can be measured and from which the moisture content in the sample can be determined. The results show that the new method has a good precision (with the relative standard deviation <0.96%), high sensitivity (the limit of quantitation=0.005%) and good accuracy (the relative differences <1.4%). Therefore, the method is quite suitable for many uses in research and industrial applications.

  12. Use of Gas Chromatography-Mass Spectrometry (GC-MS) in Nonscience Major Course Laboratory Experiments

    NASA Astrophysics Data System (ADS)

    Kostecka, Keith S.; Lerman, Zafra M.; Angelos, Sanford A.

    1996-06-01

    Gas chromatography-mass spectrometry (GC-MS) has been utilized with nonscience majors in the courses: "Modern Methods in Science: Discovering Molecular Secrets"; "The Extraordinary Chemistry of Ordinary Things"; "From Ozone to Oil Spills: Chemistry, the Environment and You"; and "Crime Lab Chemistry: Solving Crime through Analytical Chemistry". Our efforts have centered on introducing prospective science communicators (film, video, radio, television, and journalism majors) to science relative to their majors and personal interests. Quality lecture-discussion topics, "mystery"-based laboratory activities have assisted in introducing and/or explaining specific areas of chemistry that attempt to reduce fear of subject matter. Students have also used GC-MS, as a form of alternative assessment, in course projects that have been based on their majors, personal interests, and cultural backgrounds. Students have also conducted advanced independent work in different areas of chemistry, including the analysis of nail polishes and lacquers and eleven aromatic compounds present in three different brands of gasoline.

  13. Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

    PubMed Central

    Field, Christopher R.; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C.; Rose-Pehrsson, Susan L.

    2014-01-01

    The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples. PMID:25145416

  14. Improvements in bis(cyclopentadienyl)magnesium purity as determined with gas chromatography-mass spectroscopy

    SciTech Connect

    BARTRAM,MICHAEL E.

    2000-03-08

    Bis(cyclopentadienyl)magnesium (MgCp2) is used commonly as a source for doping nitride materials with magnesium. Increased oxygen incorporation known to accompany the use of MgCp2 makes the purity of this precursor an important consideration in nitride CVD. Gas chromatography-mass spectroscopy (GCMS) methods have now been developed for the identification of volatile impurities in MgCp2. Diethylether, an oxygen containing organic compound (CH{sub 3}CH{sub 2}OCH{sub 2}CH{sub 3}), and additional organic impurities were found in the MgCp2 supplied by three manufacturers. Subsequent refinements in the synthetic processes by these companies have resulted in the availability of MgCp2 free of ether and other organic impurities as determined by GCMS.

  15. New procedure for the determination of Hansen solubility parameters by means of inverse gas chromatography.

    PubMed

    Adamska, K; Bellinghausen, R; Voelkel, A

    2008-06-27

    The Hansen solubility parameter (HSP) seems to be a useful tool for the thermodynamic characterization of different materials. Unfortunately, estimation of the HSP values can cause some problems. In this work different procedures by using inverse gas chromatography have been presented for calculation of pharmaceutical excipients' solubility parameter. The new procedure proposed, based on the Lindvig et al. methodology, where experimental data of Flory-Huggins interaction parameter are used, can be a reasonable alternative for the estimation of HSP values. The advantage of this method is that the values of Flory-Huggins interaction parameter chi for all test solutes are used for further calculation, thus diverse interactions between test solute and material are taken into consideration.

  16. H2S Analysis in Biological Samples Using Gas Chromatography with Sulfur Chemiluminescence Detection

    PubMed Central

    Vitvitsky, Victor; Banerjee, Ruma

    2015-01-01

    Hydrogen sulfide (H2S) is a metabolite and signaling molecule in biological tissues that regulates many physiological processes. Reliable and sensitive methods for H2S analysis are necessary for a better understanding of H2S biology and for the pharmacological modulation of H2S levels in vivo. In this chapter, we describe the use of gas chromatography coupled to sulfur chemiluminescence detection to measure the rates of H2S production and degradation by tissue homogenates at physiologically relevant concentrations of substrates. This method allows separation of H2S from other sulfur compounds and provides sensitivity of detection to ~15 pg (or 0.5 pmol) of H2S per injected sample. PMID:25725519

  17. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    PubMed

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-05

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources.

  18. Accurate measurements of thermodynamic properties of solutes in ionic liquids using inverse gas chromatography.

    PubMed

    Mutelet, Fabrice; Jaubert, Jean-Noël

    2006-01-13

    Activity coefficients at infinite dilution of 29 organic compounds in two room temperature ionic liquids were determined using inverse gas chromatography. The measurements were carried out at different temperatures between 323.15 and 343.15K. To establish the influence of concurrent retention mechanisms on the accuracy of activity coefficients at infinite dilution for 1-butyl-3-methylimidazolium octyl sulfate and 1-ethyl-3-methylimidazolium tosylate, phase loading studies of the net retention volume per gram of packing as a function of the percent phase loading were used. It is shown that most of the solutes are retained largely by partition with a small contribution from adsorption on 1-butyl-3-methylimidazolium octyl sulfate and that the n-alkanes are retained predominantly by interfacial adsorption on 1-ethyl-3-methylimidazolium tosylate.

  19. Interaction between hydroxypropyl methylcellulose and biphasic calcium phosphate after steam sterilisation: capillary gas chromatography studies

    PubMed Central

    Bourges, Xavier; Schmitt, Michel; Amouriq, Yves; Daculsi, Guy; Legeay, Gilbert; Weiss, Pierre

    2001-01-01

    The purpose of this study was to check the chemical stability of an injectable bone substitute (IBS) composed of a 50/50 w/w mixture of a 2.92% hydroxypropyl methylcellulose (HPMC) solution in deionised water containing biphasic calcium phosphate (BCP) granules (60% hydroxyapatite/40% β-tricalcium phosphate w/w). After separation of the organic and mineral phases, capillary gas chromatography (GC) was used to study the possible modification of HPMC due to the contact with BCP granules following steam sterilisation and 32 days of storage at room temperature. HPMC was extracted from IBS in aqueous medium, and a dialytic method was then use to extract calcium phosphate salts from HPMC. The percentage of HPMC extracted from BCP was 98.5% ± 0.5% as measured by a UV method. GC showed no chemical modifications after steam sterilisation and storage. PMID:11556737

  20. Dispersive surface properties of glass-ionomer cements determined by inverse gas chromatography

    NASA Astrophysics Data System (ADS)

    Andrzejewska, E.; Voelkel, A.; Andrzejewski, M.; Limanowska-Shaw, H.

    2005-05-01

    The surface properties of several glass-ionomer cements (GIC), restorative dental materials, (GC-Fuji, Chemadent G-J, Ketac Fil and Ketac Molar) were investigated for the first time by means of inverse gas chromatography. This method enables characterization of surface activity in dispersive (non-polar) and acid-base interactions. The ability of the surface of glass-ionomers to participate in dispersive interactions was expressed by the use of the dispersive component of surface free energy γsd. This parameter was determined with satisfactory precision, meaning that the values of γsd can be further used in the discussion of the influence of the type of GIC, its preparation and the storage time on the surface properties. The greatest capacity for dispersive interactions was revealed by Ketac Molar and the lowest by GC-Fuji. Dispersive interactions in the surface activity of glass-ionomers increased with increasing storage time after cement preparation.

  1. [Determination of residual epichlorohydrin and sym-dichloroisopropyl alcohol in cationic etherified reagent by gas chromatography].

    PubMed

    Zhou, Weiyi; Fan, Guoliang; Jiang, Dongfeng

    2004-11-01

    A method for the determination of the residual epichlorohydrin and sym-dichloroisopropyl alcohol in cationic etherified reagent by gas chromatography has been established. Methyl benzoate, which has high extraction efficiency for the two components, was used as extractant. With an HP-5 capillary column, the two components were baseline separated and they eluted before the extractant. The linear ranges achieved were 5 - 590 mg/kg for epichlorohydrin and 21 - 480 mg/kg for sym-dichloroisopropyl alcohol. The limits of detection were 1.2 mg/kg for epichlorohydrin and 2.2 mg/kg for sym-dichloroisopropyl alcohol. Recoveries for epichlorohydrin were 95.93% - 103.42% with relative standard deviations of 2.4% - 10.6% and those for sym-dichloroisopropyl alcohol were 98.54% - 107.40% with relative standard deviations of 6.6% -11.1%. The method is simple, fast, and convenient.

  2. Simultaneous determination of amphetamines and ketamines in urine by gas chromatography/mass spectrometry.

    PubMed

    Lin, Huei Ru; Lua, Ahai Chang

    2006-01-01

    A method for the simultaneous determination of amphetamines and ketamines (ketamine, norketamine and dehydronorketamine) in urine samples by gas chromatography/mass spectrometry was developed and validated. Urine samples were extracted with organic solvent and derivatized with trifluoroacetic anhydride (TFAA). The limits of detection and limits of quantification for each analyte were lower than 19 and 30 ng/mL, respectively. Within-day and between-day precisions were within 0.5% and 10.6%, respectively. Biases for three levels of control samples were within -10.6% and +7.8%. The concentration of dehydronorketamine was greater than those of ketamine or norketamine in 19 of 35 ketamine-positive samples. A group of 110 human urine samples previously determined to contain at least one of the target analytes was analyzed using the new method, and excellent agreement was observed with previous results.

  3. [Determination of organophosphorous pesticide residues in red wine by solid phase microextraction-gas chromatography].

    PubMed

    Hu, Yuan; Liu, Wenmin; Zhou, Yanming; Guan, Yafeng

    2006-05-01

    A method for the determination of 12 organophosphorus pesticide residues (OPs) in red wine by fiber solid phase microextraction (SPME) coupled with gas chromatography (GC) was developed and validated. The SPME phase was prepared by sol-gel technology of physical incorporation. The extraction conditions were optimized with the results of stirring rate of 1,250 r/min, NaCl mass concentration of 150 g/L, and extraction time of 30 min. With the sample volume of 25 mL, the relative standard deviations (RSD) of peak areas for most of OPs were below 5%, and the detection limits of OPs were in the range of 5 ng/L-0.38 microg/L. It can be seen from the results that this method has the potential to analyze OPs in other beverages and soft drinking materials.

  4. [Determination of doping in human urine by gas chromatography-high resolution mass spectrometry].

    PubMed

    Xing, Yan-Yi; Liu, Xin; Zhang, Yu-Mei; Wang, Xiao-Bing; Xu, You-Xuan

    2012-12-01

    A method was evaluated for determination of twenty-one doping (including nandrolone, boldenone and methandienone) in human urine by gas chromatography-high resolution mass spectrometry. Samples were prepared by liquid-liquid extraction, concentrated, TMS derivatization and limit of detection at ng x mL(-1) by MID/GC/HRMS. According to the code of the World Anti-Doping Agency (WADA), precision and recoveries of the procedure were evaluated by replicate analysis (n = 6), the recoveries in the range of 66%-103%, with the RSD below 10.0%. The precision within the day of the method with three different concentrations was also determined RSD were less than 9.5%, 10.0% and 9.7%.

  5. [Determination of buprofezin, methamidophos, acephate, and triazophos residues in Chinese tea samples by gas chromatography].

    PubMed

    Zhang, Shuiba; Yi, Jun; Ye, Jianglei; Zheng, Wenhui; Cai, Xueqin; Gong, Zhenbin

    2004-03-01

    A method has been developed for the simultaneous determination of buprofezin, methamidophos, acephate and triazophos residues in Chinese tea samples. The pesticide residues were extracted from tea samples with a mixture of ethyl acetate and n-hexane (50:50, v/v) at 45 degrees C. The extracts were subsequently treated with a column packed with 40 mg of active carbon by gradient elution with ethyl acetate and n-hexane. Buprofenzin and the three organophosphorus pesticides were analyzed by gas chromatography using a DB-210 capillary column and a nitrogen-phosphorus detector. The recoveries for spiked standards were 73.4%-96.9%. The relative standard deviations were all within 4.63%. The limits of quantitation (3sigma) in the tea samples were about 7.0-12.0 microg/kg.

  6. High-speed, low-pressure gas chromatography-mass spectrometry for essential oil analysis.

    PubMed

    Poynter, Samuel D H; Shellie, Robert A

    2008-07-18

    Analysis of parsley and fennel essential oils was performed by using low-pressure gas chromatography-mass spectrometry (GC-MS). The low-pressure instrument configuration was achieved by fitting a GC-MS instrument with a 530microm I.D. capillary column and an appropriate capillary restrictor at the inlet of the column. Comparison of the performance of the low-pressure GC-MS setup was made with fast GC-MS using a narrow-bore capillary column. By comparing the two approaches side-by-side the benefits of low-pressure GC-MS for characterisation of moderately complex essential oils comprising less than 50 detectable components can be fully appreciated. Although efficiency is sacrificed, the improved sample capacity of the 530microm I.D. column leads to higher peak intensities and in-turn better mass spectral library matching thus providing highly satisfactory results.

  7. Pesticide residue analysis of vegetables by gas chromatography with electron-capture detection.

    PubMed

    Fenoll, José; Hellín, Pilar; Martínez, Carmen M; Flores, Pilar

    2007-01-01

    A new and original analytical method was developed for the routine analysis of 28 multiclass pesticide residues in vegetables (green pepper, red pepper, and tomato). The extraction was performed with acetone, and the pesticides were partitioned into ethyl acetate-cyclohexane (1 + 1, v/v). Residue levels in vegetables were determined by gas chromatography (GC) with electron-capture detection. Residue identities were confirmed by GC coupled with mass spectrometry in the selected ion monitoring mode. The average recoveries in pepper and tomato obtained for all analytes studied were 67.3 and 123.1%, respectively, with relative standard deviation between 1.8 and 7.0%. The detection limit for the pesticides studied varied from 0.1 to 2.6 microg/kg. The proposed method was applied to the analysis of these compounds in vegetables grown in experimental greenhouses.

  8. [Differentiation of ballpoint pen inks by thermodesorption and gas chromatography-mass spectrometry].

    PubMed

    Bügler, Jürgen; Buchner, Hans; Dallmayer, Anton

    2004-01-01

    Differentiation and classification of ink entries with dated samples of a reference collection are important aspects in the examination of questioned documents. Classification of writing inks is presently achieved by analysis of dyes and colorants contained in the ink. This technique has its limitations in newly developed ink formulations with identical dye composition but differing in their solvents and binder resins. This paper introduces a method for the determination of solvents and binder resins of an ink sample directly from paper without sample preparation. This aim is accomplished by thermodesorption of the sample followed by gas chromatography/mass spectroscopy. The method was tested on numerous samples of ballpoint pen inks, which were subsequently grouped into several solvent and resin subgroups. A case study shows the applicability of the newly developed method.

  9. Determination of organochlorine pesticides in skins and leather by gas chromatography.

    PubMed

    Font, J; Marsal, A

    1998-06-19

    The simultaneous determination of residues of lindane (gamma-HCH) and 10 other organochlorine pesticides (OCPs) in skins and leather was carried out by gas chromatography (GC) with electron-capture detection (ECD). GC with mass spectrometric detection was used to identity confirmation. Samples were extracted with hexane. The extracts were concentrated, and cleaned up on a Florisil column. Dibromooctafluorobiphenyl was added as internal standard. Hide fortifications of 0.5 an d5.0 ppm yielded average lindane recoveries of 98% and 96%, respectively. OCPs was determined in 57 samples of skins purchased from American, European and African countries in 1996-1997. OCPs were not detected in any of the American and European samples. Residues of lindane were found in 56% of African samples.

  10. Confirmatory tests for drugs in the workplace by gas chromatography-mass spectrometry.

    PubMed

    Goldberger, B A; Cone, E J

    1994-07-15

    The Mandatory Guidelines for Federal Workplace Drug Testing Programs require the use of gas chromatography-mass spectrometry (GC-MS) for the confirmation of presumptive positive urine specimens. This review focuses upon GC-MS methods developed specifically for forensic confirmation of amphetamine, methamphetamine, 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid (THC-acid), benzoylecgonine, morphine, codeine and phencyclidine in urine for purposes of workplace drug testing. In addition, current laboratory issues pertaining to each drug class are reviewed. Generally, drug assays utilized either liquid-liquid or solid-phase extraction methods, derivatization if necessary, and GC-MS detection operating in the selected ion monitoring mode or by full scan acquisition.

  11. Automation of solid-phase microextraction-gas chromatography-mass spectrometry extraction of eucalyptus volatiles.

    PubMed

    Zini, Cláudia A; Lord, Heather; Christensen, Eva; de, Assis Teotĵnio F; Caramão, Elina B; Pawliszyn, Janusz

    2002-03-01

    Solid-phase microextraction (SPME) coupled with gas chromatography (GC)-ion-trap mass spectrometry (ITMS) is employed to analyze fragrance compounds from different species of eucalyptus trees: Eucalyptus dunnii, Eucalyptus saligna, Eucalyptus grandis, and hybrids of other species. The analyses are performed using an automated system for preincubation, extraction, injection, and analysis of samples. The autosampler used is a CombiPAL and has much flexibility for the development of SPME methods and accommodates a variety of vial sizes. For automated fragrance analysis the 10- and 20-mL vials are the most appropriate. The chromatographic separation and identification of the analytes are performed with a Varian Saturn 4D GC-ITMS using an HP-5MS capillary column. Several compounds of eucalyptus volatiles are identified, with good reproducibility for both the peak areas and retention times. Equilibrium extraction provides maximal sensitivity but requires additional consideration for the effect of carryover. Preequilibrium extraction allows good sensitivity with minimal carryover.

  12. Determination of ibogaine in plasma by gas chromatography--chemical ionization mass spectrometry.

    PubMed

    Ley, F R; Jeffcoat, A R; Thomas, B F

    1996-02-02

    Ibogaine is naturally occurring indole alkaloid that is currently being considered as a treatment medication for drug dependence. Although there have been a variety of investigations regarding the mechanisms of action and pharmacology of ibogaine, relatively little has been reported regarding quantitative methods. Because of the paucity of analytical methodologies, studies involving the pharmacokinetics and metabolism of ibogaine have also been limited. A method is described for the determination of ibogaine levels in plasma by gas chromatography -- methane chemical ionization mass spectrometry. [13C2H3]Ibogaine was synthesized and used as an internal standard to control for recovery during sample preparation. The assay requires one ml of plasma and is shown to be a selective and sensitive means of ibogaine quantitation.

  13. Rapid method for determination of carbonyl groups in lignin compounds by headspace gas chromatography.

    PubMed

    Li, Jing; Hu, Hui-Chao; Chai, Xin-Sheng

    2015-07-24

    The paper reports on a novel method for rapid determination of carbonyl in lignins by headspace gas chromatography (HS-GC). The method involves the quantitative carbonyl reduction for aldehydes in 2min at room temperature or for acetones in 30min at 80°C by sodium borohydride solution in a closed headspace sample vial. After the reaction, the solution was acidified by injecting sulfuric acid solution and the hydrogen released to the headspace was determined by GC using thermal-conductivity detector. The results showed that with the addition of SiO2 powder, the reduction reaction of carbonyl groups can be greatly facilitated. The method has a good measurement precision (RSD<7.74%) and accuracy (relative error <10% compared with a reference method) in the carbonyl quantification. It is suitable to be used for rapid determination of carbonyl content in lignin and related materials.

  14. Characterization of gamma irradiated petrolatum eye ointment base by headspace-gas chromatography-mass spectrometry.

    PubMed

    Hong, Lan; Altorfer, Hans

    2002-06-20

    The effects of gamma irradiation on petrolatum eye ointment base (EOB) and its ingredients (white petrolatum, liquid paraffin, and wool fat) were studied at different irradiation doses. Forty-one volatile radiolysis products were detected and identified by a combined system of headspace-gas chromatography-mass spectrometry (HS-GC-MS). The characteristics of the radiolysis products and the degradation pathway were discussed in each case, respectively. GC method demonstrates that the component distribution patterns of eye ointment as well as its individual ingredients have no differences before and after gamma irradiation. The influence of gamma treatment on EOB was quantitatively determined at 15, 25 and 50 kGy. The concentrations of the radiolysis products increase linearly with increasing doses. Both qualitative and quantitative data show that irradiated eye ointment is safe for human use.

  15. Characterization and quantification of fluoxymesterone metabolite in horse urine by gas chromatography/mass spectrometry.

    PubMed

    Yamada, Masayuki; Aramaki, Sugako; Hosoe, Tomoo; Kurosawa, Masahiko; Kijima-Suda, Isao; Saito, Koichi; Nakazawa, Hiroyuki

    2008-07-01

    Fluoxymesterone, an anabolic steroid with the 17alpha-methyl,17beta-hydroxy group, has been developed as an oral formulation for therapeutic purposes. However, it is also used illegally in racehorses to enhance racing performance. In this study, we detected 9alpha-fluoro-17,17-dimethyl-18-norandrostane-4,13-dien-11beta-ol-3-one by gas chromatography/mass spectrometry (GC/MS), which has not been reported as a fluoxymesterone metabolite so far in horse. It was synthesized for use as a reference standard, and characterized on the basis of (1)H NMR and (13)C NMR spectra, as well as GC/MS EI mass spectra of TMS derivatives. It was excreted as the main metabolite in horse urine, and its reference standard could be synthesized easily. Therefore, this metabolite could be a useful target for a doping test of fluoxymesterone in racehorses.

  16. Surface Lewis acid-base properties of polymers measured by inverse gas chromatography.

    PubMed

    Shi, Baoli; Zhang, Qianru; Jia, Lina; Liu, Yang; Li, Bin

    2007-05-18

    Surface Lewis acid-base properties are significant for polymers materials. The acid constant, K(a) and base constant, K(b) of many polymers were characterized by some researchers with inverse gas chromatography (IGC) in recent years. In this paper, the surface acid-base constants, K(a) and K(b) of 20 kinds of polymers measured by IGC in recent years are summarized and discussed, including seven polymers characterized in this work. After plotting K(b) versus K(a), it is found that the polymers can be encircled by a triangle. They scatter in two regions of the triangle. Four polymers exist in region I. K(b)/K(a) of the polymers in region I are 1.4-2.1. The other polymers exist in region II. Most of the polymers are relative basic materials.

  17. Enthalpy of adsorption for hydrocarbons on concrete by inverse gas chromatography.

    PubMed

    Widegren, Jason A; Bruno, Thomas J

    2011-07-15

    Enthalpies of adsorption, ΔH(a), are reported for several light hydrocarbons on normal construction concrete. ΔH(a), which are a measure of the adhesion strength of a molecule on a surface, were determined by gas-solid chromatography with a packed column containing 60-80 mesh concrete particles. With this approach, the specific retention volume for a compound is measured as a function of temperature, and these data are used to calculate ΔH(a). For the hydrocarbons studied, we found that ΔH(a) was relatively large for unsaturated hydrocarbons. These are the first determinations of ΔH(a) of hydrocarbons on construction concrete, but useful comparisons with other ionic solids such as clays can be made.

  18. Gas chromatography-mass spectrometry-based metabolic profiling of cerebrospinal fluid from epileptic dogs.

    PubMed

    Hasegawa, Tetsuya; Sumita, Maho; Horitani, Yusuke; Tamai, Reo; Tanaka, Katsuhiro; Komori, Masayuki; Takenaka, Shigeo

    2014-04-01

    Epilepsy is a common neurological disorder with seizures, but diagnostic approaches in veterinary clinics remain limited. Cerebrospinal fluid (CSF) is a body fluid used for diagnosis in veterinary medicine. In this study, we explored canine epilepsy diagnostic biomarkers using gas chromatography-mass spectrometry (GC-MS)-based metabolic profiling of CSF and multivariate data analysis. Profiles for subjects with idiopathic epilepsy differed significantly from those of healthy controls and subjects with symptomatic epilepsy. Among 60 identified metabolites, the levels of 20 differed significantly among the three groups. Glutamic acid was significantly increased in idiopathic epilepsy, and some metabolites including ascorbic acid were changed in both forms of epilepsy. These findings show that metabolic profiles of CSF differ between idiopathic and symptomatic epilepsy and that metabolites including glutamic acid and ascorbic acid in CSF may be useful for diagnosis of canine epilepsy.

  19. Gas Chromatography-Mass Spectrometry-Based Metabolic Profiling of Cerebrospinal Fluid from Epileptic Dogs

    PubMed Central

    HASEGAWA, Tetsuya; SUMITA, Maho; HORITANI, Yusuke; TAMAI, Reo; TANAKA, Katsuhiro; KOMORI, Masayuki; TAKENAKA, Shigeo

    2013-01-01

    ABSTRACT Epilepsy is a common neurological disorder with seizures, but diagnostic approaches in veterinary clinics remain limited. Cerebrospinal fluid (CSF) is a body fluid used for diagnosis in veterinary medicine. In this study, we explored canine epilepsy diagnostic biomarkers using gas chromatography-mass spectrometry (GC-MS)-based metabolic profiling of CSF and multivariate data analysis. Profiles for subjects with idiopathic epilepsy differed significantly from those of healthy controls and subjects with symptomatic epilepsy. Among 60 identified metabolites, the levels of 20 differed significantly among the three groups. Glutamic acid was significantly increased in idiopathic epilepsy, and some metabolites including ascorbic acid were changed in both forms of epilepsy. These findings show that metabolic profiles of CSF differ between idiopathic and symptomatic epilepsy and that metabolites including glutamic acid and ascorbic acid in CSF may be useful for diagnosis of canine epilepsy. PMID:24334864

  20. [Determination of the writing age of blue ballpoint ink by gas chromatography].

    PubMed

    Wang, Yan; Yao, Lijuan; Zhao, Pengcheng; Wang, Jinghan; Wang, Yanji

    2005-03-01

    A method of identifying the writing age of blue ballpoint ink has been established for imperative demand of forensic laboratory. The content of the volatile component in blue ballpoint ink was determined by gas chromatography (GC). The absorbance of the dye in the blue ballpoint ink was measured by ultraviolet-visible spectrometry (UV-Vis). A writing age curve of the blue ballpoint ink has been established by the ratio of the content of the volatile components and the dye, based on the identification of 74 kinds of blue ballpoint inks, from both domestic and international origins. The change of benzyl alcohol or phenoxyethyl alcohol was tested with the writing age. Blue ballpoint inks of different kinds were detected and the repeatability of the experiment was investigated. The results indicated that the method is reliable and systematic, and especially suitable for practical cases.

  1. Monitoring and characterization of ink vehicle autoxidation by inverse gas chromatography.

    PubMed

    Castr, C; Dorris, G M; Daneault, C

    2002-09-06

    It is now well-established that increased usage of vegetable oils in offset ink formulas aggravates the deinking problems in recycling plants during summer months. The seasonal loss of brightness of recycled paper has been ascribed to increased bonding of oxidatively aged prints to the paper surface. The progress of the oxidative aging of soya bean and linseed oils was followed by inverse gas chromatography. We first report here the rate and extent of vegetable oil oxidation, by measuring the changes in Kovats retention index as a function of the oxidation time. We then characterized the physicochemical changes accompanying the oxidation of vegetable oils from measurements of the partial heat of mixing in the infinite dilution regime.

  2. Gas chromatography-mass spectroscopy study of tert-butylarsine stability and purification

    NASA Astrophysics Data System (ADS)

    Bartram, M. E.; Breiland, W. G.; Bruskas, L. A.; Killeen, K. P.

    2000-06-01

    We have used gas chromatography-mass spectroscopy (GCMS) to study the decomposition of TBA ( tert-butylarsine, H 2AsC(CH 3) 3) in storage containers at room temperature. Over a four-week period, as much as 1% of the TBA decomposed to arsine and isobutane in a stainless-steel bottle. Several freeze-thaw purification schemes were tested. Use of a liquid-nitrogen bath left a substantial amount of arsine and isobutane in the bottle, while an ice water bath removed all of the arsine but left residual isobutane. Evacuation of the storage container at room temperature removed both arsine and isobutane to below the GCMS detection limits. However, this approach did lead to significant TBA loss. Storing TBA in a Teflon-lined bottle and in a high-surface-to-volume stainless-steel container did not change the decomposition rate measurably, suggesting that stainless-steel surfaces do not promote TBA decomposition.

  3. [Determination of 10 volatile organic compounds in toys by headspace gas chromatography-mass spectrometry].

    PubMed

    Lü, Qing; Zhang, Qing; Kang, Suyuan; Bai, Hua; Wang, Chao

    2010-08-01

    A headspace gas chromatography-mass spectrometry (HS-GC-MS) method was developed for the determination of 10 residual volatile organic compounds (VOCs) in toys. The experimental conditions such as headspace temperature, headspace time and the analytical conditions of GC-MS were optimized. Toy samples were treated at 140 degrees C for 45 min, and then the evolved products were separated on a DB-624 column, determined by MS and quantified by external standard method. The recoveries were from 79% to 106% and the relative standard deviations (RSDs) were from 0.4% to 5.6%. The linear range was 0.001 - 2.0 microg with a good linear correlation coefficient (r > 0.994 0) and the limits of quantification (LOQ) were less than 0 66 mg/kg. The method is accurate, simple, rapid, and is suitable for the analysis of residual VOCs in various toys.

  4. Thermal and hydrothermal treatment of silica gels as solid stationary phases in gas chromatography.

    PubMed

    El-Naggar, Ashraf Yehia

    2013-01-01

    Silica gel was prepared and treated thermally and hydrothermally and was characterized as solid stationary phase in gas chromatography. The characteristics have been evaluated in terms of polarity, selectivity, and separation efficiencies. These parameters were used to assess the outer silica surface contributions and the degree of surface deactivation brought about by different treatment techniques. The parent silica elutes the paraffinic hydrocarbons with high efficiency of separation and elutes aromatic hydrocarbons with nearly good separation and has bad separation of alcohols. The calcined silica at 500°C and 1000°C has a pronounced effect on the separation of aromatic hydrocarbons compared with the parent silica and hydrothermal treatment of silica. With respect to alcohols separation, the obtained bad separations using treated and untreated silica reflect the little effect of the thermal and hydrothermal treatment on the silica surface deactivation.

  5. Identification of 19 phthalic acid esters in dairy products by gas chromatography with mass spectrometry.

    PubMed

    Wu, Pinggu; Cai, Chenggang; Yang, Dajin; Wang, Liyuan; Zhou, Yan; Shen, Xianghong; Ma, Bingjie; Tang, Jun

    2015-01-01

    A detection method for 19 kinds of phthalic acid ester compounds analyzed by n-hexane/ether/acetonitrile 1:7:8 v/v/v mixed solvent extraction, quick, easy, cheap, effective, rugged, and safe purification and internal standard method of quantitative gas chromatography with mass spectrometry was established. This method can effectively remove interfering materials, such as lipids, fatty acids, and pigments, from dairy products. The 19 kinds of phthalic acid ester compounds were within a 0.025-0.2 mg/kg range, the recovery rate was 65.2-125.7%, relative standard deviation was 7.9-15.4% (n = 6), and the limit of detection was 0.005-0.02 mg/kg. Concentrations of the 19 kinds of phthalic acid ester compounds ranged between 0.01 and 0.12 mg/kg in ten dairy materials and 20 dairy products. The established method is simple, rapid, accurate, and highly sensitive.

  6. Quantitative Analysis and Fingerprint Profiles for Quality Control of Fructus Schisandrae by Gas Chromatography: Mass Spectrometry

    PubMed Central

    Xia, Yong-Gang; Yang, Bing-You; Liang, Jun; Yang, Qi; Wang, Di; Kuang, Hai-Xue

    2014-01-01

    This paper describes a simple, rapid, and effective quality assessment method for Fructus Schisandrae by gas chromatography-mass spectrum (GC-MS). The method was established by using specific lignan fingerprint profiles and quantitation of characteristic compounds in this herbal medicine. The GC-MS fingerprints of 15 batches of Schisandra samples from different regions of China showed similar lignan profiles. Five peaks were selected as characteristic peaks, and all of these were identified by using GC-MS techniques. The relative retention times of these characteristic peaks in the GC-MS fingerprint were established as an important parameter for identification of Schisandra samples. Meanwhile, relative peak areas may be a feasible approach to discriminate the S. chinensis and S. sphenanthera. Finally, these pharmacologically active constituents in the titled plant, schisandrins A–C and schizandrols A and B, were quantitatively determined using a validated GC-MS method. PMID:24574919

  7. Determination of glyphosate, glyphosate metabolites, and glufosinate in human serum by gas chromatography-mass spectrometry.

    PubMed

    Motojyuku, Megumi; Saito, Takeshi; Akieda, Kazuki; Otsuka, Hiroyuki; Yamamoto, Isotoshi; Inokuchi, Sadaki

    2008-11-15

    This paper describes an assay for the determination of glyphosate (GLYP), glyphosate metabolites [(aminomethyl) phosphonic acid] (AMPA), and glufosinate (GLUF) in human serum. After protein precipitation using acetonitrile and solid-phase extraction, serum samples were derivatized and analyzed by gas chromatography-mass spectrometry (GC-MS). The assay was linear over a concentration range of 3-100.0 microg/ml for GLYP, AMPA, and GLUF. The overall recoveries for the three compounds were >73%. The intra- and inter-day variations were <15%. Precision and accuracy were 6.4-10.6% and 88.2-103.7%, respectively. The validated method was applied to quantify the GLYP and AMPA content in the serum of a GLYP-poisoned patient. In conclusion, the method was successfully applied for the determination of GLYP and its metabolite AMPA in serum obtained from patient of GLYP-poisoning.

  8. Enantiomeric analysis of chiral compounds in irradiated foods using multidimensional gas chromatography.

    PubMed

    Barba, Carmen; Santa-María, Guillermo; Flores, Gema; Herraiz, Marta; Calvo, Marta M

    2010-01-27

    The usefulness of both solid phase microextraction (SPME) and multidimensional gas chromatography (MDGC) coupled to mass spectrometry (MS) to detect chiral compounds in irradiated cheese was evaluated. The enantiomeric resolution of relevant chiral aroma compound was achieved by analyzing the extracts obtained from SPME by means of a permethylated beta-CD stationary phase as the main column of the multidimensional system to separate specific selected cuts containing components unresolved in the first dimension. The proposed procedure allowed to determine, in less than 90 min, that no significant variations had been produced in the stereoisomeric distribution of limonene, 3-hydroxybutanone, and 2,3-butanediol in cheese when applying irradiation doses ranging from 0 to 8 kGy.

  9. Analysis of the surface energy of pharmaceutical powders by inverse gas chromatography.

    PubMed

    Grimsey, Ian M; Feeley, Jane C; York, Peter

    2002-02-01

    The behavior of pharmaceutical solids, during either processing or use, can be noticeably affected by the surface energetics of the constituent particles. Several techniques exist to measure the surface energy, for example, sessile drop, and dynamic contact angle measurements. Inverse gas chromatography (IGC) is an alternative technique where the powder surface is characterized by the retention behavior of minute quantities of well-characterized vapors that are injected into a column containing the material of interest. Recently published articles using IGC on pharmaceutical powders have ranged from linking surface energetic data with triboelectric charging to studying the effect of surface moisture on surface energetics. Molecular modelling has also recently been used to explore the links between IGC data and the structural and chemical factors that influence surface properties, thereby achieving predictive knowledge regarding powder behavior during processing. In this minireview, the reported applications of IGC in the analysis of pharmaceutical powders are summarized and the major findings highlighted.

  10. Analysis of Iranian rosemary essential oil: application of gas chromatography-mass spectrometry combined with chemometrics.

    PubMed

    Jalali-Heravi, Mehdi; Moazeni, Rudabeh Sadat; Sereshti, Hassan

    2011-05-06

    This paper focuses on characterization of the components of Iranian rosemary essential oil using gas chromatography-mass spectrometry (GC-MS). Multivariate curve resolution (MCR) approach was used to overcome the problem of background, baseline offset and overlapping/embedded peaks in GC-MS. The analysis of GC-MS data revealed that sixty eight components exist in the rosemary essential oil. However, with the help of MCR this number was extended to ninety nine components with concentrations higher than 0.01%, which accounts for 98.23% of the total relative content of the rosemary essential oil. The most important constituents of the Iranian rosemary are 1,8-cineole (23.47%), α-pinene (21.74%), berbonone (7.57%), camphor (7.21%) and eucalyptol (4.49%).

  11. Determination of acrylamide in nerve tissue homogenates by electron-capture gas chromatography.

    PubMed

    Poole, C F; Sye, W F; Zlatkis, A; Spencer, P S

    1981-11-06

    Acrylamide in biological samples can be determined by gas chromatography with electron-capture detection after conversion to its 2,3-dibromopropionamide derivative. The derivatization is carried out in aqueous solution, plasma or tissue homogenates by ionic bromination and the reaction conditions and sample clean-up are described. The detection limit corresponds to 9.5.10(-12)g of acrylamide on column or 8.4.10(-9)g in the final biological extract (0.5 ml). The overall recovery of acrylamide spiked samples at the nanogram level exceeds 80%. It was found that the accumulation of free acrylamide in the sciatic nerve distal region of rats intoxicated with acrylamide was less than 2-8 ppm.

  12. Accelerating analysis for metabolomics, drugs and their metabolites in biological samples using multidimensional gas chromatography.

    PubMed

    Mitrevski, Blagoj S; Kouremenos, Konstantinos A; Marriott, Philip J

    2009-05-01

    Gas chromatography (GC) with mass spectrometry (MS) is one of the great enabling analytical tools available to the chemical and biochemical analyst for the measurement of volatile and semi-volatile compounds. From the analysis result, it is possible to assess progress in chemical reactions, to monitor environmental pollutants in a wide range of soil, water or air samples, to determine if an athlete or horse trainer has contravened doping laws, or if crude oil has migrated through subsurface rock to a reservoir. Each of these scenarios and samples has an associated implementation method for GC-MS. However, few samples and the associated interpretation of data is as complex or important as biochemical sample analysis for trace drugs or metabolites. Improving the analysis in both the GC and MS domains is a continual search for better separation, selectivity and sensitivity. Multidimensional methods are playing important roles in providing quality data to address the needs of analysts.

  13. Gas chromatography of safranal as preferable method for the commercial grading of saffron (Crocus sativus L.).

    PubMed

    Bononi, Monica; Milella, Paola; Tateo, Fernando

    2015-06-01

    We present a new extraction protocol, using ethyl alcohol as a solvent, to evaluate safranal by gas chromatography (GC). A linear response was obtained with R(2)=0.995 and a reproducibility standard deviation of 4.7-6.0%. The limit of detection and limit of quantitation were 0.05 and 0.25gkg(-1), respectively. The GC data for several samples of powdered saffron from different origins were compared to specific absorbance values measured according to the ISO Normative 3632-1:2011 method. The aroma strength of saffron samples quantitated by GC and the specific absorbance values of safranal by the UV method did not correlate. Quantitative evaluation of safranal by GC appears to be more specific and useful for commercial comparisons of saffron quality.

  14. Comparison of comprehensive two-dimensional gas chromatography in conventional and stop-flow modes.

    PubMed

    Harynuk, James; Górecki, Tadeusz

    2006-02-10

    A new mode of operation for comprehensive two-dimensional gas chromatography (GC x GC), stop-flow GC x GC, was introduced recently. In this technique, the flow in the primary column is stopped for a brief period of time during each modulation cycle, allowing for a secondary separation time that is longer than would otherwise be permitted by the modulation period in conventional GC x GC. This allows the modulation period and the secondary separation time to become independent variables, and greatly increases the flexibility of the system. In this paper, separations obtained under similar conditions for both conventional and stop-flow GC x GC are presented, demonstrating the advantages that stop-flow GC x GC provides over conventional GC x GC for certain separations.

  15. Preparative monohydroxyflavanone syntheses and a protocol for gas chromatography-mass spectrometry analysis of monohydroxyflavanones.

    PubMed

    Kagawa, Hitoshi; Shigematsu, Asako; Ohta, Shigeru; Harigaya, Yoshihiro

    2005-05-01

    We describe a facile efficient, and preparative approach for monohydroxyflavanone syntheses. Using this protocol, a hydroxyl is regio-selectively introduced at one carbon of a flavanone A- or B-ring per synthesis. The seven possible isomers were each synthesized from the corresponding monomethoxymethoxylated 2'-hydroxychalcones in acidic solution. These monohydroxyflavanones were characterized using a gas chromatography-mass spectrometry (GC-MS) system that incorporated a DB-5 capillary column. Ours is the first report of a preparative synthetic method during which a single hydroxyl can be selectively added to a flavanone A- or B-ring at any position. We are also the first to develop a procedure that separates the seven isomers by GC and characterizes the mass spectra of the isomers. Both the synthetic method and the GC-MS conditions may become important tools during future flavanone metabolism and oxidation studies.

  16. Gas chromatography/mass spectrometry for the determination of nitrosamines in red wine.

    PubMed

    Lona-Ramirez, Fernando J; Gonzalez-Alatorre, Guillermo; Rico-Ramírez, Vicente; Perez-Perez, Ma Cristina I; Castrejón-González, Edgar O

    2016-04-01

    N-nitrosamines (NAms) are highly active carcinogens that have been detected in food and beverages. Currently certain studies report their presence in red wine, while others fail to detect their presence. In this study the head space solid phase micro-extraction technique coupled to gas chromatography-mass spectrometry (HS-SPME-GC-MS) was applied to quantify four NAms in different types of red wine. The technique was found to be a simple, precise, fast and environmentally friendly alternative for the quantification of volatile NAms. A factorial analysis was carried out to evaluate the influence of the parameters on the HS-SPME technique. This is the first study that such analysis has been reported and where NAms in red wine have been quantified using HS-SPME-GC-MS. The method was validated by calculating the linearity, limit of detection and quantification. Two of the four NAms analyzed were found to be present in red wine samples.

  17. Determination of descriptors for fragrance compounds by gas chromatography and liquid-liquid partition.

    PubMed

    Karunasekara, Thushara; Poole, Colin F

    2012-04-27

    Retention factors on a minimum of eight stationary phases at various temperatures by gas-liquid chromatography and liquid-liquid partition coefficients for five totally organic biphasic systems were combined to estimate descriptors for 28 fragrance compounds with an emphasis on compounds that are known or potential allergens. The descriptors facilitated the estimation of several properties of biological and environmental interest (sensory irritation threshold, odor detection threshold, nasal pungency threshold, skin permeability from water, skin-water partition coefficients, octanol-water partition coefficients, absorption by air particles, adsorption by diesel soot particles, air-water partition coefficients, and adsorption by film water). The descriptors are suitable for use in the solvation parameter model and facilitate the estimation of a wide range of physicochemical, chromatographic, biological, and environmental properties using existing models.

  18. Quantitative detection of trace explosive vapors by programmed temperature desorption gas chromatography-electron capture detector.

    PubMed

    Field, Christopher R; Lubrano, Adam; Woytowitz, Morgan; Giordano, Braden C; Rose-Pehrsson, Susan L

    2014-07-25

    The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples.

  19. Determination of pyrethroid residues in tobacco and cigarette smoke by capillary gas chromatography.

    PubMed

    Cai, Jibao; Liu, Baizhan; Zhu, Xiaolan; Su, Qingde

    2002-07-26

    The extraction of fenpropathrin, cyhalothrin, cypermethrin, fenvalerate and deltamethrin from tobacco (Nicotina tobaccum) and cigarette smoke condensate with acetone, followed by partition of resulting acetone mixture with petroleum ether, was investigated and found suitable for capillary gas chromatography (GC) residue analysis. Florisil column clean-up was found to provide clean-up procedure for tobacco and cigarette smoke condensate permitting analysis to < or = 0.01 microgram.g-1 for most of the pyrethroids by GC with a 63Ni electron capture detector (GC-ECD). Quantitative determination was obtained by the method of external standards. Cigarettes made from flue-cured tobacco spiked with different amounts of pyrethroids were used and the pyrethroid levels in mainstream smoke were determined. For all the pyrethroid residues, 1.51-15.50% were transferred from tobacco into cigarette smoke.

  20. Fast gas chromatography of explosive compounds using a pulsed-discharge electron capture detector.

    PubMed

    Collin, Olivier L; Niegel, Claudia; Derhodes, Kate E; McCord, Bruce R; Jackson, Glen P

    2006-07-01

    The detection of a mixture of nine explosive compounds, including nitrate esters, nitroaromatics, and a nitramine in less than 140 sec is described. The new method employs a commercially available pulsed-discharge electron capture detector (PDECD) coupled with a microbore capillary gas chromatography (GC) column in a standard GC oven to achieve on-column detection limits between 5 and 72 fg for the nine explosives studied. The PDECD has the benefit that it uses a pulsed plasma to generate the standing electron current instead of a radioactive source. The fast separation time limits on-column degradation of the thermally labile compounds and decreases the peak widths, which results in larger peak intensities and a concomitant improvement in detection limits. The combination of short analysis time and low detection limits make this method a potential candidate for screening large numbers of samples that have been prepared using techniques such as liquid-liquid extraction or solid-phase microextraction.