Sample records for gas chromatography hs-gc

  1. Using Single Drop Microextraction for Headspace Analysis with Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Riccio, Daniel; Wood, Derrick C.; Miller, James M.

    2008-07-01

    Headspace (HS) gas chromatography (GC) is commonly used to analyze samples that contain non-volatiles. In 1996, a new sampling technique called single drop microextraction, SDME, was introduced, and in 2001 it was applied to HS analysis. It is a simple technique that uses equipment normally found in the undergraduate laboratory, making it ideal for instructional use, especially to illustrate HS analysis or as an alternative to solid-phase microextraction (SPME) to which it is very similar. The basic principles and practice of HS-GC using SDME are described, including a complete review of the literature. Some possible experiments are suggested using water and N -methylpyrrolidone (NMP) as solvents.

  2. Utilizing two detectors in the measurement of trichloroacetic acid in human urine by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-05-16

    A reaction headspace gas chromatography (HS-GC) technique was investigated for quantitatively analyzing trichloroacetic acid in human urine. This method is based on the decomposition reaction of trichloroacetic acid under high-temperature conditions. The carbon dioxide and chloroform formed from the decomposition reaction can be respectively detected by the thermal conductivity detection HS-GC and flame ionization detection HS-GC. The reaction can be completed in 60 min at 90°C. This method was used to quantify 25 different human urine samples, which had a range of trichloroacetic acid from 0.52 to 3.47 mg/L. It also utilized two different detectors, the thermal conductivity detector and the flame ionization detector. The present reaction HS-GC method is accurate, reliable and well suitable for batch detection of trichloroacetic acid in human urine. Copyright © 2018 John Wiley & Sons, Ltd.

  3. Using Single Drop Microextraction for Headspace Analysis with Gas Chromatography

    ERIC Educational Resources Information Center

    Riccio, Daniel; Wood, Derrick C.; Miller, James M.

    2008-01-01

    Headspace (HS) gas chromatography (GC) is commonly used to analyze samples that contain non-volatiles. In 1996, a new sampling technique called single drop microextraction, SDME, was introduced, and in 2001 it was applied to HS analysis. It is a simple technique that uses equipment normally found in the undergraduate laboratory, making it ideal…

  4. Characterization of Aronia melanocarpa volatiles by headspace-solid-phase microextraction (HS-SPME), simultaneous distillation/extraction (SDE), and gas chromatography-olfactometry (GC-O) methods.

    PubMed

    Kraujalytė, Vilma; Leitner, Erich; Venskutonis, Petras Rimantas

    2013-05-22

    The profiles of volatile constituents of berry fruit of two Aronia melanocarpa genotypes were evaluated by headspace-solid-phase microextraction (HS-SPME), simultaneous distillation and extraction (SDE), and gas chromatography-olfactometry (GC-O). In total, 74 volatile compounds were identified in chokeberry juice, 3-penten-2-one, 3,9-epoxy-p-menth-1-ene, and benzaldehyde being the most abundant constituents; however, their percentage concentrations were remarkably different in the HS-SPME and SDE profiles. Twenty two aroma-active compounds were detected and characterized by the trained panelists in HS-SPME using GC-O detection frequency analysis. Olfactometry revealed that ethyl-2-methyl butanoate, ethyl-3-methyl butanoate, ethyl decanoate ("fruity" aroma notes), nonanal ("green" notes), unidentified compound possessing "moldy" odor, and some other volatiles may be very important constituents in formation of chokeberry aroma of both analyzed plant cultivars.

  5. Efficient determination of average valence of manganese in manganese oxides by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-08-18

    This work investigates a new reaction headspace gas chromatographic (HS-GC) technique for efficient quantifying average valence of manganese (Mn) in manganese oxides. This method is on the basis of the oxidation reaction between manganese oxides and sodium oxalate under the acidic condition. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively analyzed by headspace gas chromatography. The data showed that the reaction in the closed headspace vial can be completed in 20min at 80°C. The relative standard deviation of this reaction HS-GC method in the precision testing was within 1.08%, the relative differences between the new method and the reference method (titration method) were no more than 5.71%. The new HS-GC method is automated, efficient, and can be a reliable tool for the quantitative analysis of average valence of manganese in the manganese oxide related research and applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Accurate determination of fiber water-retaining capability at process conditions by headspace gas chromatography.

    PubMed

    Zhang, Shu-Xin; Chai, Xin-Sheng; He, Liang

    2016-09-16

    This work reports on a method for the accurate determination of fiber water-retaining capability at process conditions by headspace gas chromatography (HS-GC) method. The method was based the HS-GC measurement of water vapor on a set closed vials containing in a given amount pulp with different amounts of water addition, from under-saturation to over-saturation. By plotting the equilibrated water vapor signal vs. the amount of water added in pulp, two different trend lines can be observed, in which the transition of the lines corresponds to fiber water-retaining capability. The results showed that the HS-GC method has good measurement precision (much better than the reference method) and good accuracy. The present method can be also used for determining pulp fiber water-retaining capability at the process temperatures in both laboratory research and mill applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Determination of volatile marker compounds in raw ham using headspace-trap gas chromatography.

    PubMed

    Bosse Née Danz, Ramona; Wirth, Melanie; Konstanz, Annette; Becker, Thomas; Weiss, Jochen; Gibis, Monika

    2017-03-15

    A simple, reliable and automated method was developed and optimized for qualification and quantification of aroma-relevant volatile marker compounds of North European raw ham using a headspace (HS)-Trap gas chromatography-mass spectrometry (GC-MS) and GC-flame ionization detector (FID) analysis. A total of 38 volatile compounds were detected with this HS-Trap GC-MS method amongst which the largest groups were ketones (12), alcohols (8), hydrocarbons (7), aldehydes (6) and esters (3). The HS-Trap GC-FID method was optimized for the parameters: thermostatting time and temperature, vial and desorption pressure, number of extraction cycles and salt addition. A validation for 13 volatile marker compounds with limits of detection in ng/g was carried out. The optimized method can serve as alternative to conventional headspace and solid phase micro extraction methods and allows users to determine volatile compounds in raw hams making it of interest to industrial and academic meat scientists. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Application of headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography (GC x GC) for the chemical profiling of volatile oils in complex herbal mixtures.

    PubMed

    Di, Xin; Shellie, Robert A; Marriott, Philip J; Huie, Carmen W

    2004-04-01

    The coupling of headspace solid-phase microextraction (HS-SPME) with comprehensive two-dimensional gas chromatography (GC x GC) was shown to be a powerful technique for the rapid sampling and analysis of volatile oils in complex herbal materials. When compared to one-dimensional (1-D) GC, the improved analytical capabilities of GC x GC in terms of increased detection sensitivity and separation power were demonstrated by using HS-SPME/GC x GC for the chemical profiling (fingerprinting) of essential/volatile oils contained in herbal materials of increasing analytical complexity. More than 20 marker compounds belonging to Panax quinquefolius (American ginseng) can be observed within the 2-D contour plots of ginseng itself, a mixture of ginseng and another important herb (P. quinquefolius/Radix angelicae sinensis), as well as a mixture of ginseng and three other herbs (P. quinquefolius /R. angelicae sinensis/R. astragali/R. rehmanniae preparata). Such analytical capabilities should be important towards the authentication and quality control of herbal products, which are receiving increasing attention as alternative medicines worldwide. In particular, the presence of Panax in the herb formulation could be readily identified through its specific peak pattern in the 2-D GC x GC plot.

  9. Ullage Tank Fuel-Air Mixture Characterisation

    DTIC Science & Technology

    2011-12-01

    247-252 Woodrow, J.E., Seiber, J.N., 1988, ‘Vapor-pressure measurement of complex mixtures by headspace gas chromatography ’, Journal of...Electron Ionisation FAR Fuel to Air Mass Ratio FID Flame Ionisation Detector GC Gas Chromatography HS Headspace MS Mass Spectrometry NIST...Determination of volatile substances in biological headspace gas chromatography ’, Journal of Chromatography A, vol. 674, pp. 25-62 Shepherd, J.E, Krok, J.C

  10. Rapid quantitative detection of glucose content in glucose injection by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-10-20

    This work investigates an automated technique for rapid detecting the glucose content in glucose injection by reaction headspace gas chromatography (HS-GC). This method is based on the oxidation reaction of glucose in glucose injection with potassium dichromate. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively detected by GC. The results show that the relative standard deviation (RSD) of the present method was within 2.91%, and the measured glucose contents in glucose injection closely match those quantified by the reference method (relative differences <6.45%). The new HS-GC technique is rapid, practical and can be used to the batch detection of the glucose content in glucose injection related applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Determination of the Degree of Substitution of Cationic Guar Gum by Headspace-Based Gas Chromatography during Its Synthesis.

    PubMed

    Wan, Xiaofang; Guo, Congbao; Feng, Jiarui; Yu, Teng; Chai, Xin-Sheng; Chen, Guangxue; Xie, Wei-Qi

    2017-08-16

    This study reports on a headspace-based gas chromatography (HS-GC) technique for determining the degree of substitution (DS) of cationic guar gum during the synthesis process. The method is based on the determination of 2,3-epoxypropyltrimethylammonium chloride in the process medium. After a modest pretreatment procedure, the sample was added to a headspace vial containing bicarbonate solution for measurement of evolved CO 2 by HS-GC. The results showed that the method had a good precision (relative standard deviation of <3.60%) and accuracy for the 2,3-epoxypropyltrimethylammonium chloride measurement, with recoveries in the range of 96-102%, matching with the data obtained by a reference method, and were within 12% of the values obtained by the more arduous Kjeldahl method for the calculated DS of cationic guar gum. The HS-GC method requires only a small volume of sample and, thus, is suitable for determining the DS of cationic guar gum in laboratory-scale process-related applications.

  12. Determination of the solubility of low volatility liquid organic compounds in water using volatile-tracer assisted headspace gas chromatography.

    PubMed

    Zhang, Shu-Xin; Chai, Xin-Sheng; Barnes, Donald G

    2016-02-26

    This study reports a new headspace gas chromatographic method (HS-GC) for the determination of water solubility of low volatility liquid organic compounds (LVLOs). The HS-GC analysis was performed on a set of aqueous solutions containing a range of concentrations of toluene-spiked (as a tracer) LVLOs, from under-saturation to over-saturation. A plot of the toluene tracer GC signal vs. the concentration of the LVLO results in two lines of different slopes that intersect at the concentration corresponding to the compound's solubility in water. The results showed that the HS-GC method has good precision (RSD <6.3%) and good accuracy, in which the relative deference between the data measured by the HS-GC method and the reference method were within 6.0%. The HS-GC method is simple and particularly suitable for measuring the solubility of LVLOs at elevated temperatures. This approach should be of special interest to those concerned about the impact of the presence of low-volatility organic liquids in waters of environmental and biological systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Determination of trace level genotoxic impurities in small molecule drug substances using conventional headspace gas chromatography with contemporary ionic liquid diluents and electron capture detection.

    PubMed

    Ho, Tien D; Yehl, Peter M; Chetwyn, Nik P; Wang, Jin; Anderson, Jared L; Zhong, Qiqing

    2014-09-26

    Ionic liquids (ILs) were used as a new class of diluents for the analysis of two classes of genotoxic impurities (GTIs), namely, alkyl/aryl halides and nitro-aromatics, in small molecule drug substances by headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD). This novel approach using ILs as contemporary diluents greatly broadens the applicability of HS-GC for the determination of high boiling (≥ 130°C) analytes including GTIs with limits of detection (LOD) ranging from 5 to 500 parts-per-billion (ppb) of analytes in a drug substance. This represents up to tens of thousands-fold improvement compared to traditional HS-GC diluents such as dimethyl sulfoxide (DMSO) and dimethylacetamide (DMAC). Various ILs were screened to determine their suitability as diluents for the HS-GC/ECD analysis. Increasing the HS oven temperatures resulted in varying responses for alkyl/aryl halides and a significant increase in response for all nitroaromatic GTIs. Linear ranges of up to five orders of magnitude were found for a number of analytes. The technique was validated on two active pharmaceutical ingredients with excellent recovery. This simple and robust methodology offers a key advantage in the ease of method transfer from development laboratories to quality control environments since conventional validated chromatographic data systems and GC instruments can be used. For many analytes, it is a cost effective alternative to more complex trace analytical methodologies like LC/MS and GC/MS, and significantly reduces the training needed for operation. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Validation of an analytical method for nitrous oxide (N2O) laughing gas by headspace gas chromatography coupled to mass spectrometry (HS-GC-MS): forensic application to a lethal intoxication.

    PubMed

    Giuliani, N; Beyer, J; Augsburger, M; Varlet, V

    2015-03-01

    Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Analysis of residual monomers in dendritic methacrylate copolymers and composites by HPLC and headspace-GC/MS.

    PubMed

    Viljanen, Eeva K; Langer, Sarka; Skrifvars, Mikael; Vallittu, Pekka K

    2006-09-01

    The aim of this study was to analyze the residual monomer content of photopolymerized dendritic methacrylate copolymers and particulate filler composites. Headspace-gas chromatography/mass spectrometry (HS-GC/MS) was compared with high performance liquid chromatography (HPLC). The resin mixtures consisted of a dendritic methacrylate monomer, methyl methacrylate and acetoacetoxyethyl methacrylate in varied proportions. In addition, one of the composites contained 1,4-butanediol dimethacrylate. Camphorquinone and 2-(N,N-dimethylamino)ethyl methacrylate were used as the light-activated initiator system. The content of residual methyl methacrylate and acetoacetoxyethyl methacrylate after 40 s photopolymerization were analyzed with HPLC and HS-GC/MS. The content of residual methyl methacrylate decreased and residual acetoacetoxyethyl methacrylate increased with increasing concentration of acetoacetoxyethyl methacrylate in the resin mixture. The results with both methods had the same trend. The addition of acetoacetoxyethyl methacrylate enhanced the copolymerization of methyl methacrylate, but did not decrease the total residual monomer content. The HS-GC/MS method was found to be a feasible method in the analysis of low-boiling residuals in dental polymers.

  16. Determination of different recreational drugs in sweat by headspace solid-phase microextraction gas chromatography mass spectrometry (HS-SPME GC/MS): Application to drugged drivers.

    PubMed

    Gentili, Stefano; Mortali, Claudia; Mastrobattista, Luisa; Berretta, Paolo; Zaami, Simona

    2016-09-10

    A procedure based on headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) has been developed for the determination of most commonly used drugs of abuse in sweat of drivers stopped during roadside controls. DrugWipe 5A sweat screening device was used to collect sweat by a specific pad rubbed gently over forehead skin surface. The procedure involved an acid hydrolysis, a HS-SPME extraction for drugs of abuse but Δ(9)-tetrahydrocannabinol, which was directly extracted in alkaline medium HS-SPME conditions, a GC separation of analytes by a capillary column and MS detection by electron impact ionisation. The method was linear from the limit of quantification (LOQ) to 50ng drug per pad (r(2)≥0.99), with an intra- and inter-assay precision and accuracy always less than 15% and an analytical recovery between 95.1% and 102.8%, depending on the considered analyte. Using the validated method, sweat from 60 apparently intoxicated drivers were found positive to one or more drugs of abuse, showing sweat patches testing as a viable economic and simple alternative to conventional (blood and/or urine) and non conventional (oral fluid) testing of drugs of abuse in drugged drivers. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Simplex optimization of headspace factors for headspace gas chromatography determination of residual solvents in pharmaceutical products.

    PubMed

    Grodowska, Katarzyna; Parczewski, Andrzej

    2013-01-01

    The purpose of the present work was to find optimum conditions of headspace gas chromatography (HS-GC) determination of residual solvents which usually appear in pharmaceutical products. Two groups of solvents were taken into account in the present examination. Group I consisted of isopropanol, n-propanol, isobutanol, n-butanol and 1,4-dioxane and group II included cyclohexane, n-hexane and n-heptane. The members of the groups were selected in previous investigations in which experimental design and chemometric methods were applied. Four factors were taken into consideration in optimization which describe HS conditions: sample volume, equilibration time, equilibrium temperature and NaCl concentration in a sample. The relative GC peak area served as an optimization criterion which was considered separately for each analyte. Sequential variable size simplex optimization strategy was used and the progress of optimization was traced and visualized in various ways simultaneously. The optimum HS conditions appeared different for the groups of solvents tested, which proves that influence of experimental conditions (factors) depends on analyte properties. The optimization resulted in significant signal increase (from seven to fifteen times).

  18. Efficient quantification of water content in edible oils by headspace gas chromatography with vapour phase calibration.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-06-01

    An automated and accurate headspace gas chromatographic (HS-GC) technique was investigated for rapidly quantifying water content in edible oils. In this method, multiple headspace extraction (MHE) procedures were used to analyse the integrated water content from the edible oil sample. A simple vapour phase calibration technique with an external vapour standard was used to calibrate both the water content in the gas phase and the total weight of water in edible oil sample. After that the water in edible oils can be quantified. The data showed that the relative standard deviation of the present HS-GC method in the precision test was less than 1.13%, the relative differences between the new method and a reference method (i.e. the oven-drying method) were no more than 1.62%. The present HS-GC method is automated, accurate, efficient, and can be a reliable tool for quantifying water content in edible oil related products and research. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  19. Determination of organotin compounds by headspace solid-phase microextraction-gas chromatography-pulsed flame-photometric detection (HS-SPME-GC-PFPD).

    PubMed

    Bravo, Manuel; Lespes, Gaëtane; De Gregori, Ida; Pinochet, Hugo; Gautier, Martine Potin

    2005-12-01

    A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 mum PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L(-1) in water and close to ng (Sn) kg(-1) in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME-GC-PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices.

  20. Approaches of aroma extraction dilution analysis (AEDA) for headspace solid phase microextraction and gas chromatography-olfactometry (HS-SPME-GC-O): Altering sample amount, diluting the sample or adjusting split ratio?

    PubMed

    Feng, Yunzi; Cai, Yu; Sun-Waterhouse, Dongxiao; Cui, Chun; Su, Guowan; Lin, Lianzhu; Zhao, Mouming

    2015-11-15

    Aroma extract dilution analysis (AEDA) is widely used for the screening of aroma-active compounds in gas chromatography-olfactometry (GC-O). In this study, three aroma dilution methods, (I) using different test sample volumes, (II) diluting samples, and (III) adjusting the GC injector split ratio, were compared for the analysis of volatiles by using HS-SPME-AEDA. Results showed that adjusting the GC injector split ratio (III) was the most desirable approach, based on the linearity relationships between Ln (normalised peak area) and Ln (normalised flavour dilution factors). Thereafter this dilution method was applied in the analysis of aroma-active compounds in Japanese soy sauce and 36 key odorants were found in this study. The most intense aroma-active components in Japanese soy sauce were: ethyl 2-methylpropanoate, ethyl 2-methylbutanoate, ethyl 3-methylbutanoate, ethyl 4-methylpentanoate, 3-(methylthio)propanal, 1-octen-3-ol, 2-methoxyphenol, 4-ethyl-2-methoxyphenol, 2-methoxy-4-vinylphenol, 2-phenylethanol, and 4-hydroxy-5-ethyl-2-methyl-3(2H)-furanone. Copyright © 2015. Published by Elsevier Ltd.

  1. Determination of microstickies in recycled whitewater by headspace gas chromatography

    Treesearch

    X.-S. Chai; J.C. Samp; Q.F. Yang; H.N. Song; J.Y. Zhu

    2007-01-01

    This study proposed a novel headspace gas chromatographic (HS-GC) method for determination of adhesive contaminants (microstickies) in recycled whitewater, a fiber containing process stream, in the paper mill. It is based on the adsorption behavior of toluene (as a tracer) on the hydrophobic surface of microstickies, which affects the apparent vapor-liquid...

  2. Rapid determination of floral aroma compounds of lilac blossom by fast gas chromatography combined with surface acoustic wave sensor.

    PubMed

    Oh, Se Yeon; Shin, Hyun Du; Kim, Sung Jean; Hong, Jongki

    2008-03-07

    A novel analytical method using fast gas chromatography combined with surface acoustic wave sensor (GC/SAW) has been developed for the detection of volatile aroma compounds emanated from lilac blossom (Syringa species: Syringa vulgaris variginata and Syringa dilatata). GC/SAW could detect and quantify various fragrance emitted from lilac blossom, enabling to provide fragrance pattern analysis results. The fragrance pattern analysis could easily characterize the delicate differences in aromas caused by the substantial difference of chemical composition according to different color and shape of petals. Moreover, the method validation of GC/SAW was performed for the purpose of volatile floral actual aroma analysis, achieving a high reproducibility and excellent sensitivity. From the validation results, GC/SAW could serve as an alternative analytical technique for the analysis of volatile floral actual aroma of lilac. In addition, headspace solid-phase microextraction (HS-SPME) GC-MS was employed to further confirm the identification of fragrances emitted from lilac blossom and compared to GC/SAW.

  3. Determination of total acid content in biomass hydrolysates by solvent-assisted and reaction based headspace gas chromatography.

    PubMed

    Huang, Liu-Lian; Hu, Hui-Chao; Chen, Li-Hui

    2015-11-27

    This work reports on a novel method for the determination of total acid (TA) in biomass hydrolysates by a solvent-assisted and reaction-based headspace gas chromatography (HS-GC). The neutralization reaction between the acids in hydrolysates and bicarbonate in an ethanol (50%) aqueous solution was performed in a closed headspace sample vial, from which the carbon dioxide generated from the reaction was detected by HS-GC. It was found that the addition of ethanol can effectively eliminate the precipitation of some organic acids in the biomass hydrolysates. The results showed that the reaction and headspace equilibration can be achieved within 45min at 70°C; the method has a good precision (RSD<3.27%) and accuracy (recovery of 97.4-105%); the limit of quantification is 1.36μmol. The present method is quite suitable to batch analysis of TA content in hydrolysate for the biorefinery related research. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Determination of maximal amount of minor gases adsorbed in a shale sample by headspace gas chromatography.

    PubMed

    Zhang, Chun-Yun; Hu, Hui-Chao; Chai, Xin-Sheng; Pan, Lei; Xiao, Xian-Ming

    2014-02-07

    In this paper, we present a novel method for determining the maximal amount of ethane, a minor gas species, adsorbed in a shale sample. The method is based on the time-dependent release of ethane from shale samples measured by headspace gas chromatography (HS-GC). The study includes a mathematical model for fitting the experimental data, calculating the maximal amount gas adsorbed, and predicting results at other temperatures. The method is a more efficient alternative to the isothermal adsorption method that is in widespread use today. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Determination of microstickies in recycled whitewater by headspace gas chromatography.

    PubMed

    Chai, X-S; Samp, J C; Yang, Q F; Song, H N; Zhang, D C; Zhu, J Y

    2006-03-03

    This study proposed a novel headspace gas chromatographic (HS-GC) method for determination of adhesive contaminants (microstickies) in recycled whitewater, a fiber containing process stream, in the paper mill. It is based on the adsorption behavior of toluene (as a tracer) on the hydrophobic surface of microstickies, which affects the apparent vapor-liquid equilibration partitioning of toluene. It was found that the equilibrium concentration of toluene in the vapor phase is inversely proportional to the apparent effective surface area of microstickies that remain in the corresponding solution. Thus, the amount of microsticky materials in the recycled whitewater can be quantified by HS-GC via indirect measurement of the toluene content in the vapor phase of the sample without any pretreatment. The presented method is simple, rapid and automated.

  6. Quantification of dimethylsulfoniopropionate (DMSP) in Acropora spp. of reef-building coral using mass spectrometry with deuterated internal standard.

    PubMed

    Swan, Hilton B; Deschaseaux, Elisabeth S M; Jones, Graham B; Eyre, Bradley D

    2017-03-01

    Dimethylsulfoniopropionate (DMSP) in scleractinian coral is usually analysed indirectly as dimethylsulfide (DMS) using gas chromatography (GC) with a sulfur-specific detector. We developed a headspace GC method for mass spectral analysis of DMSP in branching coral where hexa-deuterated DMSP (d 6 -DMSP) was added to samples and standards to optimise the analytical precision and quantitative accuracy. Using this indirect HS-GC-MS method, we show that common coral sample handling techniques did not alter DMSP concentrations in Acropora aspera and that endogenous DMS was insignificant compared to the store of DMSP in A. aspera. Field application of the indirect HS-GC-MS method in all seasons over a 5-year period at Heron Island in the southern Great Barrier Reef indicated that healthy colonies of A. aspera ordinarily seasonally conserve their branch tip store of DMSP; however, this store increased to a higher concentration under extended thermal stress conditions driven by a strong El Niño Southern Oscillation event. A liquid chromatography mass spectral method (LC-MS) was subsequently developed for direct analysis of DMSP in branching coral, also utilising the d 6 -DMSP internal standard. The quantitative comparison of DMSP in four species of Acropora coral by indirect HS-GC-MS and direct LC-MS analyses gave equivalent concentrations in A. aspera only; in the other three species, HS-GC-MS gave consistently higher concentrations, indicating that indirect analysis of DMSP may lead to artificially high values for some coral species. Graphical Abstract Dimethylsulfoniopropionate (DMSP) was quantified in Acropora spp. of branching coral using deuterated stable isotope dilution mass spectrometry.

  7. A novel method for the determination of adsorption partition coefficients of minor gases in a shale sample by headspace gas chromatography.

    PubMed

    Zhang, Chun-Yun; Hu, Hui-Chao; Chai, Xin-Sheng; Pan, Lei; Xiao, Xian-Ming

    2013-10-04

    A novel method has been developed for the determination of adsorption partition coefficient (Kd) of minor gases in shale. The method uses samples of two different sizes (masses) of the same material, from which the partition coefficient of the gas can be determined from two independent headspace gas chromatographic (HS-GC) measurements. The equilibrium for the model gas (ethane) was achieved in 5h at 120°C. The method also involves establishing an equation based on the Kd at higher equilibrium temperature, from which the Kd at lower temperature can be calculated. Although the HS-GC method requires some time and effort, it is simpler and quicker than the isothermal adsorption method that is in widespread use today. As a result, the method is simple and practical and can be a valuable tool for shale gas-related research and applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Efficacy of head space solid-phase microextraction coupled to gas chromatography-mass spectrometry method for determination of the trace extracellular hydrocarbons of cyanobacteria.

    PubMed

    Guan, Wenna; Zhu, Tao; Wang, Yuejie; Zhang, Zhongyi; Jin, Zhao; Wang, Cong; Bai, Fali

    2016-09-01

    Hydrocarbons are widespread in cyanobacteria, and the biochemical synthetic pathways were recently identified. Intracellular fatty alka(e)nes of cyanobacteria have been detected by liquid-liquid extraction (LLE) coupled to gas chromatography-mass spectrometry (GC/MS). However, whether fatty alka(e)nes can be released to cyanobacterial culture media remains to be clarified. This work develops a sensitive method for analyzing the trace level of extracellular hydrocarbons in cyanobacterial culture media by head space solid-phase microextraction (HS-SPME) coupled to GC/MS. Headspace (HS) extraction mode using polydimethylsiloxane fiber to extract for 30min at 50°C was employed as the optimal extraction conditions. Five cyanobacterial fatty alka(e)nes analogs including pentadecene (C15:1), pentadecane (C15:0), heptadecene (C17:1), heptadecane (C17:0), nonadecane (C19:0) were analyzed, and the data obtained from HS-SPME-GC/MS method were quantified using internal standard peak area comparisons. Limits of detection (LOD), limits of quantitation (LOQ), linear dynamic range, precisions (RSD) and recovery for the analysis of extracellular fatty alka(e)nes of cyanobacteria by HS-SPME-GC/MS were evaluated. The LODs limits of detection (S/N = 3) varied from 10 to 21 ng L-1. The correlation coefficients (r) of the calibration curves ranged from 0.9873 to 0.9977 with a linearity from 0.1 to 50 μg L-1. The RSD values were ranging from 7.8 to 14.0% and from 4.0 to 8.8% at 1.0 μg L-1 and 10.0 μg L-1 standard solutions, respectively. Comparative analysis of extracellular fatty alka(e)nes in the culture media of model cyanobacteria Synechocystis sp. PCC 6803 demonstrated that sensitivity of HS-SPME-GC/MS method was significantly higher than LLE method. Finally, we found that heptadecane can be released into the culture media of Synechocystis sp. PCC 6803 at the later growth period. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Development of a Direct Headspace Collection Method from Arabidopsis Seedlings Using HS-SPME-GC-TOF-MS Analysis

    PubMed Central

    Kusano, Miyako; Iizuka, Yumiko; Kobayashi, Makoto; Fukushima, Atsushi; Saito, Kazuki

    2013-01-01

    Plants produce various volatile organic compounds (VOCs), which are thought to be a crucial factor in their interactions with harmful insects, plants and animals. Composition of VOCs may differ when plants are grown under different nutrient conditions, i.e., macronutrient-deficient conditions. However, in plants, relationships between macronutrient assimilation and VOC composition remain unclear. In order to identify the kinds of VOCs that can be emitted when plants are grown under various environmental conditions, we established a conventional method for VOC profiling in Arabidopsis thaliana (Arabidopsis) involving headspace-solid-phase microextraction-gas chromatography-time-of-flight-mass spectrometry (HS-SPME-GC-TOF-MS). We grew Arabidopsis seedlings in an HS vial to directly perform HS analysis. To maximize the analytical performance of VOCs, we optimized the extraction method and the analytical conditions of HP-SPME-GC-TOF-MS. Using the optimized method, we conducted VOC profiling of Arabidopsis seedlings, which were grown under two different nutrition conditions, nutrition-rich and nutrition-deficient conditions. The VOC profiles clearly showed a distinct pattern with respect to each condition. This study suggests that HS-SPME-GC-TOF-MS analysis has immense potential to detect changes in the levels of VOCs in not only Arabidopsis, but other plants grown under various environmental conditions. PMID:24957989

  10. Quantitative analysis of total starch content in wheat flour by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-09-01

    This paper proposed a new reaction headspace gas chromatographic (HS-GC) method for efficiently quantifying the total starch content in wheat flours. A certain weight of wheat flour was oxidized by potassium dichromate in an acidic condition in a sealed headspace vial. The results show that the starch in wheat flour can be completely transferred to carbon dioxide at the given conditions (at 100 °C for 40 min) and the total starch content in wheat flour sample can be indirectly quantified by detecting the CO 2 formed from the oxidation reaction. The data showed that the relative standard deviation of the reaction HS-GC method in the precision test was less than 3.06%, and the relative differences between the new method and the reference method (titration method) were no more than 8.90%. The new reaction HS-GC method is automated, accurate, and can be a reliable tool for determining the total starch content in wheat flours in both laboratory and industrial applications. Graphical abstract The total starch content in wheat flour can be indirectly quantified by the GC detection of the CO 2 formed from the oxidation reaction between wheat flour and potassium dichromate in an acidic condition.

  11. Analysis of honeybush tea (Cyclopia spp.) volatiles by comprehensive two-dimensional gas chromatography using a single-stage thermal modulator.

    PubMed

    Ntlhokwe, Gaalebalwe; Tredoux, Andreas G J; Górecki, Tadeusz; Edwards, Matthew; Vestner, Jochen; Muller, Magdalena; Erasmus, Lené; Joubert, Elizabeth; Christel Cronje, J; de Villiers, André

    2017-07-01

    The applicability of comprehensive two-dimensional gas chromatography (GC×GC) using a single-stage thermal modulator was explored for the analysis of honeybush tea (Cyclopia spp.) volatile compounds. Headspace solid phase micro-extraction (HS-SPME) was used in combination with GC×GC separation on a non-polar × polar column set with flame ionisation (FID) detection for the analysis of fermented Cyclopia maculata, Cyclopia subternata and Cyclopia genistoides tea infusions of a single harvest season. Method optimisation entailed evaluation of the effects of several experimental parameters on the performance of the modulator, the choice of columns in both dimensions, as well as the HS-SPME extraction fibre. Eighty-four volatile compounds were identified by co-injection of reference standards. Principal component analysis (PCA) showed clear differentiation between the species based on their volatile profiles. Due to the highly reproducible separations obtained using the single-stage thermal modulator, multivariate data analysis was simplified. The results demonstrate both the complexity of honeybush volatile profiles and the potential of GC×GC separation in combination with suitable data analysis techniques for the investigation of the relationship between sensory properties and volatile composition of these products. The developed method therefore offers a fast and inexpensive methodology for the profiling of honeybush tea volatiles. Graphical abstract Surface plot obtained for the GC×GC-FID analysis of honeybush tea volatiles.

  12. Determination of epichlorohydrin and 1,3-dichloro-2-propanol in synthesis of cationic etherifying reagent by headspace gas chromatography.

    PubMed

    Tao, Zheng-Yi; Chai, Xin-Sheng; Wu, Shu-Bin

    2011-09-16

    This study demonstrates a headspace gas chromatographic(HS-GC) technique for the determination of residual epichlorohydrin (ECH) and generated 1,3-dichloro-2-propanol (DCP) in synthesis process of 3-chloro-2-hydroxypropyltrimethylammonium chloride (CHTAC). By a weight-based sampling method, coupled with significant dilution in 15.8% sodium sulfate and 0.1% silver nitrate mixed solution rapidly, the sample for HS-GC analysis is prepared. Based on the reaction stoichiometry, the conversion (R) of CHTAC during the synthesis process can be calculated from sampling weight and GC peak area. The results showed that the method has a good measurement precision (RSD<2.5%) and accuracy (recovery=101-104%) for the quantification of both ECH and DCP in the process samples. The present method is simple and accurate, which can be used for the efficient determination of the CHTAC conversion in the synthesis research. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Volatile-Compound Fingerprinting by Headspace-Gas-Chromatography Ion-Mobility Spectrometry (HS-GC-IMS) as a Benchtop Alternative to 1H NMR Profiling for Assessment of the Authenticity of Honey.

    PubMed

    Gerhardt, Natalie; Birkenmeier, Markus; Schwolow, Sebastian; Rohn, Sascha; Weller, Philipp

    2018-02-06

    This work describes a simple approach for the untargeted profiling of volatile compounds for the authentication of the botanical origins of honey based on resolution-optimized HS-GC-IMS combined with optimized chemometric techniques, namely PCA, LDA, and kNN. A direct comparison of the PCA-LDA models between the HS-GC-IMS and 1 H NMR data demonstrated that HS-GC-IMS profiling could be used as a complementary tool to NMR-based profiling of honey samples. Whereas NMR profiling still requires comparatively precise sample preparation, pH adjustment in particular, HS-GC-IMS fingerprinting may be considered an alternative approach for a truly fully automatable, cost-efficient, and in particular highly sensitive method. It was demonstrated that all tested honey samples could be distinguished on the basis of their botanical origins. Loading plots revealed the volatile compounds responsible for the differences among the monofloral honeys. The HS-GC-IMS-based PCA-LDA model was composed of two linear functions of discrimination and 10 selected PCs that discriminated canola, acacia, and honeydew honeys with a predictive accuracy of 98.6%. Application of the LDA model to an external test set of 10 authentic honeys clearly proved the high predictive ability of the model by correctly classifying them into three variety groups with 100% correct classifications. The constructed model presents a simple and efficient method of analysis and may serve as a basis for the authentication of other food types.

  14. Method development and optimization for the determination of benzene, toluene, ethylbenzene and xylenes in water at trace levels by static headspace extraction coupled to gas chromatography-barrier ionization discharge detection.

    PubMed

    Pascale, Raffaella; Bianco, Giuliana; Calace, Stefania; Masi, Salvatore; Mancini, Ignazio M; Mazzone, Giuseppina; Caniani, Donatella

    2018-05-04

    Benzene, toluene, ethylbenzene, and xylenes, more commonly named BTEX, represent one of the most ubiquitous and hazardous groups of atmospheric pollutants. The goal of our research was the trace quantification of BTEX in water by using a new simple, low-cost, and accurate method, based on headspace (HS) extraction and gas chromatography (GC) coupled to barrier ionization discharge detector (BID). This water application dealt with simple matrices without protein, fat, or humic material that adsorb target analytes, thus the external standard calibration was suitable to quantify each compound. The validation steps included the study of linearity, detection and quantification limits, and accuracy. LODs and LOQs varied from 0.159 to 1.845 μg/L and from 0.202 to 2.452 μg/L, respectively. The recovery was between 0.74 ± 0.13 and 1.15 ± 0.09; relative standard deviations (% RDSs) were less than 12.81% (n = 5) and 14.84% (n = 10). Also, GC performance was evaluated in term of efficiency, peak tailing and resolution. Preliminary results from practical applications to analyses of real samples are presented. The results indicate that static HS coupled to GC-BID is a successful method for BTEX analysis in water samples at the μg/L levels, provided that hydrocarbons interference occur at similar concentration levels. GC-BID may become a routine reference method alongside the official analytical techniques for quality control purposes of contaminated waters. Moreover, the new method is amenable to automation by using commercial HS units. Copyright © 2018. Published by Elsevier B.V.

  15. Determination of cyanide in whole blood by capillary gas chromatography with cryogenic oven trapping.

    PubMed

    Ishii, A; Seno, H; Watanabe-Suzuki, K; Suzuki, O; Kumazawa, T

    1998-11-15

    Cyanide, one of the most important toxic substances, has been found measurable with high sensitivity by capillary gas chromatography (GC) with cryogenic oven trapping upon injection of headspace (HS) vapor samples. The entire amount of cyanide in the HS sample could be cryogenically trapped prior to on-line GC analysis. A 0.5-mL volume of blood in the presence or absence of cyanide and propionitrile (internal standard, IS) was added to a vial containing 0.25 mL of distilled water, 0.3 g of Na2-SO4, 0.2 mL of 50% H3PO4, and 0.1 g of ascorbic acid (when needed), and the mixture was heated at 70 degrees C for 15 min. A 5-mL volume of the HS vapor was introduced into a GC capillary column in the splitless mode at -30 degrees C oven temperature that was programmed up to 160 degrees C for GC analysis with nitrogen-phosphorus detection. A sharp peak was obtained for cyanide under the present conditions, and backgrounds were very clean. The extraction efficiencies of cyanide and IS were 2.89-3.22 (100 or 500 ng/mL) and 2.42%, respectively. The calibration curve showed good linearity in the range of 25-1000 ng/mL and the detection limit was approximately 2 ng/mL. The coefficients of intraday and interday variations were 2.9 and 11.8%, respectively. The mean blood cyanide level measured for actual fire victims was 687 +/- 597 ng/mL (mean +/- SD, n = 9). Endogenous blood cyanide concentration for healthy subjects was 8.41 +/- 3.09 ng/mL (mean +/- SD, n = 6).

  16. Analysis of Listeria using exogenous volatile organic compound metabolites and their detection by static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS).

    PubMed

    Taylor, Carl; Lough, Fraser; Stanforth, Stephen P; Schwalbe, Edward C; Fowlis, Ian A; Dean, John R

    2017-07-01

    Listeria monocytogenes is a Gram-positive bacterium and an opportunistic food-borne pathogen which poses significant risk to the immune-compromised and pregnant due to the increased likelihood of acquiring infection and potential transmission of infection to the unborn child. Conventional methods of analysis suffer from either long turn-around times or lack the ability to discriminate between Listeria spp. reliably. This paper investigates an alternative method of detecting Listeria spp. using two novel enzyme substrates that liberate exogenous volatile organic compounds in the presence of α-mannosidase and D-alanyl aminopeptidase. The discriminating capabilities of this approach for identifying L. monocytogenes from other species of Listeria are investigated. The liberated volatile organic compounds (VOCs) are detected using an automated analytical technique based on static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS). The results obtained by SHS-MCC-GC-IMS are compared with those obtained by the more conventional analytical technique of headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). The results found that it was possible to differentiate between L. monocytogenes and L. ivanovii, based on their VOC response from α-mannosidase activity.

  17. A rapid analysis of plasma/serum ethylene and propylene glycol by headspace gas chromatography.

    PubMed

    Ehlers, Alexandra; Morris, Cory; Krasowski, Matthew D

    2013-12-01

    A rapid headspace-gas chromatography (HS-GC) method was developed for the analysis of ethylene glycol and propylene glycol in plasma and serum specimens using 1,3-propanediol as the internal standard. The method employed a single-step derivitization using phenylboronic acid, was linear to 200 mg/dL and had a lower limit of quantitation of 1 mg/dL suitable for clinical analyses. The analytical method described allows for laboratories with HS-GC instrumentation to analyze ethanol, methanol, isopropanol, ethylene glycol, and propylene glycol on a single instrument with rapid switch-over from alcohols to glycols analysis. In addition to the novel HS-GC method, a retrospective analysis of patient specimens containing ethylene glycol and propylene glycol was also described. A total of 36 patients ingested ethylene glycol, including 3 patients who presented with two separate admissions for ethylene glycol toxicity. Laboratory studies on presentation to hospital for these patients showed both osmolal and anion gap in 13 patients, osmolal but not anion gap in 13 patients, anion but not osmolal gap in 8 patients, and 1 patient with neither an osmolal nor anion gap. Acidosis on arterial blood gas was present in 13 cases. Only one fatality was seen; this was a patient with initial serum ethylene glycol concentration of 1282 mg/dL who died on third day of hospitalization. Propylene glycol was common in patients being managed for toxic ingestions, and was often attributed to iatrogenic administration of propylene glycol-containing medications such as activated charcoal and intravenous lorazepam. In six patients, propylene glycol contributed to an abnormally high osmolal gap. The common presence of propylene glycol in hospitalized patients emphasizes the importance of being able to identify both ethylene glycol and propylene glycol by chromatographic methods.

  18. A novel HS-SBSE system coupled with gas chromatography and mass spectrometry for the analysis of organochlorine pesticides in water samples.

    PubMed

    Grossi, Paula; Olivares, Igor R B; de Freitas, Diego R; Lancas, Fernando M

    2008-10-01

    A methodology to analyze organochlorine pesticides (OCPs) in water samples has been accomplished by using headspace stir bar sorptive extraction (HS-SBSE). The bars were in house coated with a thick film of PDMS in order to properly work in the headspace mode. Sampling was done by a novel HS-SBSE system whereas the analysis was performed by capillary GC coupled mass spectrometric detection (HS-SBSE-GC-MS). The extraction optimization, using different experimental parameters has been established by a standard equilibrium time of 120 min at 85 degrees C. A mixture of ACN/toluene as back extraction solvent promoted a good performance to remove the OCPs sorbed in the bar. Reproducibility between 2.1 and 14.8% and linearity between 0.96 and 1.0 were obtained for pesticides spiked in a linear range between 5 and 17 ng/g in water samples during the bar evaluation.

  19. A robust method for determining water-extractable alkylphenol polyethoxylates in textile products by reaction-based headspace gas chromatography.

    PubMed

    Zhang, Shu-Xin; Chai, Xin-Sheng; Huang, Bo-Xi; Mai, Xiao-Xia

    2015-08-07

    Alkylphenol polyethoxylates (APEO), surfactants used in the production of textiles, have the potential to move from the fabric to the skin of the person wearing the clothes, posing an inherent risk of adverse health consequences. Therefore, the textile industry needs a fast, robust method for determining aqueous extractable APEO in fabrics. The currently-favored HPLC methods are limited by the presence of a mixture of analytes (due to the molecular weight distribution) and a lack of analytical standards for quantifying results. As a result, it has not been possible to reach consensus on a standard method for the determination of APEO in textiles. This paper addresses these limitations through the use of reaction-based head space-gas chromatography (HS-GC). Specifically, water is used to simulate body sweat and extract APEO. HI is then used to react the ethoxylate chains to depolymerize the chains into iodoethane that is quantified through HS-GC, providing an estimate of the average amount of APEO in the clothing. Data are presented to justify the optimal operating conditions; i.e., water extraction at 60°C for 1h and reaction with a specified amount of HI in the headspace vial at 135°C for 4h. The results show that the HS-GC method has good precision (RSD<10%) and good accuracy (recoveries from 95 to 106%) for the quantification of APEO content in textile and related materials. As such, the method should be a strong candidate to become a standard method for such determinations. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Rapid and sensitive analysis of polychlorinated biphenyls and acrylamide in food samples using ionic liquid-based in situ dispersive liquid-liquid microextraction coupled to headspace gas chromatography.

    PubMed

    Zhang, Cheng; Cagliero, Cecilia; Pierson, Stephen A; Anderson, Jared L

    2017-01-20

    A simple and rapid ionic liquid (IL)-based in situ dispersive liquid-liquid microextraction (DLLME) method was developed and coupled to headspace gas chromatography (HS-GC) employing electron capture (ECD) and mass spectrometry (MS) detection for the analysis of polychlorinated biphenyls (PCBs) and acrylamide at trace levels from milk and coffee samples. The chemical structures of the halide-based ILs were tailored by introducing various functional groups to the cations to evaluate the effect of different structural features on the extraction efficiency of the target analytes. Extraction parameters including the molar ratio of IL to metathesis reagent and IL mass were optimized. The effects of HS oven temperature and the HS sample vial volume on the analyte response were also evaluated. The optimized in situ DLLME method exhibited good analytical precision, good linearity, and provided detection limits down to the low ppt level for PCBs and the low ppb level for acrylamide in aqueous samples. The matrix-compatibility of the developed method was also established by quantifying acrylamide in brewed coffee samples. This method is much simpler and faster compared to previously reported GC-MS methods using solid-phase microextraction (SPME) for the extraction/preconcentration of PCBs and acrylamide from complex food samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Determination of some volatile compounds in alcoholic beverage by headspace solid-phase microextraction gas chromatography - mass spectrometry

    NASA Astrophysics Data System (ADS)

    Schmutzer, G.; Avram, V.; Feher, I.; David, L.; Moldovan, Z.

    2012-02-01

    The volatile composition of alcoholic beverage was studied by headspace solid-phase microextraction (HSSPME) method and gas chromatography - mass spectrometry (GC-MS). Some volatile compounds, such as alcohols, esters, terpenes and other are mainly responsible for the flavor of fortified wines and their amounts specify the quality of the alcoholic beverages. From this perspective it is interesting to develop a rapid, selective and sensitive analytical method suitable for simultaneous quantification of the main molecules being responsible for the organoleptic characteristic of alcoholic beverages. Vermouth fortified drink was analyzed in order to characterize the volatile profile. Using the HS-SPME/GC-MS a number of twenty-six volatile compounds from a commercial market alcoholic beverage were identified. The most abundant compounds were m-thymol, o-thymol and eugenol, alongside of the ethyl ester compounds.

  2. NMR, HS-SPME-GC/MS, and HPLC/MSn Analyses of Phytoconstituents and Aroma Profile of Rosmarinus eriocalyx.

    PubMed

    Bendif, Hamdi; Miara, Mohamed Djamel; Peron, Gregorio; Sut, Stefania; Dall'Acqua, Stefano; Flamini, Guido; Maggi, Filippo

    2017-10-01

    In this work, a comprehensive study on the chemical constituents of the aerial parts of Rosmarinus eriocalyx (Lamiaceae), an aromatic shrub traditionally consumed as a food and herbal remedy in Algeria, is presented. The aroma profile was analysed by headspace solid phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC/MS), whereas the crude extract constituents were analyzed by 1 H-NMR and by high performance liquid chromatography coupled with mass spectrometry (HPLC/MS n ). Thirty-nine volatile compounds, most of them being monoterpenes, have been identified, with camphor, camphene, and α-pinene as the most abundant constituents. 1 H-NMR analysis revealed the presence of phenolic compounds and betulinic acid while HPLC/MS n allowed the identification of glycosilated and aglyconic flavonoids as well as phenylpropanoid derivatives. Some of these constituents, namely as betulinic acid, rosmanol, and cirsimaritin were reported for the first time in R. eriocalyx. © 2017 Wiley-VHCA AG, Zurich, Switzerland.

  3. A volatile tracer-assisted headspace analytical technique for determining the swelling capacity of superabsorbent polymers.

    PubMed

    Zhang, Shu-Xin; Jiang, Ran; Chai, Xin-Sheng

    2017-09-01

    This paper reports on a new method for the determination of swelling capacity of superabsorbent polymers by a volatile tracer-assisted headspace gas chromatography (HS-GC). Toluene was used as a tracer and added to the solution for polymers swelling test. Based on the differences of the tracer partitioned between the vapor and hydrogel phase before and after the polymer's swelling capacity, a transition point (corresponding to the material swelling capacity) can be observed when plotting the GC signal of toluene vs. the ratio of solution added to polymers. The present method has good precision (RSD<2.1%) and good accuracy, in which the relative deference between the data measured by the HS-GC method and the reference method were within 8.0%. The present method is very suitable to be used for testing the swelling capacity of polymers at the elevated temperatures. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Selective determination of semi-volatile thiophene compounds in water by molecularly imprinted polymer thin films with direct headspace gas chromatography sulfur chemiluminescence detection.

    PubMed

    Hijazi, Hassan Y; Bottaro, Christina S

    2018-02-26

    Water-compatible molecularly imprinted polymer (MIP) thin films are coupled with headspace gas chromatography sulfur chemiluminescence detection (HS-GC-SCD) to create a new approach for the determination of trace concentrations of thiophene compounds in water samples. Thiophene compounds are persistent, typically petrogenic, organic pollutants of concern due to their potential for biomagnification and bioaccumulation, mutagenicity, and carcinogenicity in terrestrial and aquatic fauna. Identification and quantitation in water, particularly following oil spills, is a priority. Following adsorption of the thiophenes to the MIPs, the MIP-bound analytes are analyzed directly by HS-GC-SCD, with minimal sample manipulation and virtually no organic solvent. Calibration curves of spiked seawater were linear from 5 μg L -1 to 100 μg L -1 and limits of detection (LOD) were in the range of 0.24-0.82 μg L -1 . Low matrix effects were observed in the analysis of thiophene compounds in seawater making the method suitable for use in fresh and saline waters without modification. Acceptable reproducibility was obtained for analysis of thiophene compounds from spiked seawater samples at RSDs ≤7.0% (n = 3).

  5. Influence of harvest maturity and fruit logistics on pineapple (Ananas comosus [L.] Merr.) volatiles assessed by headspace solid phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC/MS).

    PubMed

    Steingass, Christof B; Grauwet, Tara; Carle, Reinhold

    2014-05-01

    Profiling of volatiles from pineapple fruits was performed at four ripening stages using headspace solid-phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC/MS). In total, 142 volatiles were detected, of which 132 were identified. Multivariate data analysis was carried out to assess the effect of post-harvest storage on volatiles composition of green-ripe sea-freighted pineapple in comparison to air-freighted fruits harvested at full maturity. The latter fruits were characterised by volatiles described as potent odorants in pineapples, such as δ-octalactone, γ-lactones, 1-(E,Z)-3,5-undecatriene and 1,3,5,8-undecatetraene, as well as various methyl esters. In contrast, post-harvest storage of green-ripe sea-freighted fruits resulted in an increased formation of ethyl esters, acetates, acetoxy esters and alcohols, thus allowing the authentication of sea- and air-freighted pineapples, respectively. Particularly, compounds presumably derived from methyl-branched amino acid catabolism were identified in the fruits at later post-harvest stages. In addition, physicochemical traits were determined to characterise the fruit maturity stages. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Fast and solvent-free quantitation of boar taint odorants in pig fat by stable isotope dilution analysis-dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry.

    PubMed

    Fischer, Jochen; Haas, Torsten; Leppert, Jan; Lammers, Peter Schulze; Horner, Gerhard; Wüst, Matthias; Boeker, Peter

    2014-09-01

    Boar taint is a specific off-odour of boar meat products, known to be caused by at least three unpleasant odorants, with very low odour thresholds. Androstenone is a boar pheromone produced in the testes, whereas skatole and indole originate from the microbial breakdown of tryptophan in the intestinal tract. A new procedure, applying stable isotope dilution analysis (SIDA) and dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry (dynHS-TD-GC/TOFMS) for the simultaneous quantitation of these boar taint compounds in pig fat was elaborated and validated in this paper. The new method is characterised by a simple and solvent-free dynamic headspace sampling. The deuterated compounds d3-androstenone, d3-skatole and d6-indole were used as internal standards to eliminate matrix effects. The method validation performed revealed low limits of detection (LOD) and quantitation (LOQ) with high accuracy and precision, thus confirming the feasibility of the new dynHS-TD-GC/TOFMS approach for routine analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. An efficient method for the simultaneous determination of furan, 2-methylfuran and 2-pentylfuran in fruit juices by headspace solid phase microextraction and gas chromatography-flame ionisation detector.

    PubMed

    Hu, Gaofei; Zhu, Yan; Hernandez, Marta; Koutchma, Tatiana; Shao, Suqin

    2016-02-01

    A headspace solid phase microextraction (HS-SPME) procedure followed by gas chromatography-flame ionisation detector (GC-FID) analysis was developed and validated for the simultaneous analysis of furan, 2-methylfuran and 2-pentylfuran from juice samples. Extraction at 32 °C for 20 min with stirring at 600 rpm and NaCl concentration 15% (W/V) was the optimal HS-SPME condition for all the three compounds by using a carboxen/polydimethylsiloxane fused silica fibre (75 μm). The extracted compounds were base line separated on a SPB-1 GC column within 12 min. The relative standard deviations of all analytes were less than 6.7%. The recovery rates were between 90.2% and 110.1%. The limits of detection and limits of quantification were 0.056-0.23 ng/mL and 0.14-0.76 ng/mL, respectively. The results showed that the developed method was sensitive, precise, accurate and robust for the determination of furan, 2-methylfuran and 2-pentylfuran in complex matrices without interferences from other components. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  8. A pressure-affected headspace-gas chromatography method for determining calcium carbonate content in paper sample.

    PubMed

    Dai, Yi; Yu, Zhen-Hua; Zhan, Jian-Bo; Chai, Xin-Sheng; Zhang, Shu-Xin; Xie, Wei-Qi; He, Liang

    2017-07-21

    The present work reports on the development of a pressure-affected based headspace (HS) analytical technique for the determination of calcium carbonate content in paper samples. By the acidification, the carbonate in the sample was converted to CO 2 and released into the headspace of a closed vial and then measured by gas chromatography (GC). When the amount of carbonate in the sample is significant, the pressure created by the CO 2 affects the accuracy of the method. However, the pressure also causes a change in the O 2 signal in the HS-GC measurement, which is a change that can be used as an indirect measure of the carbonate in the sample. The results show that the present method has a good precision (the relative standard deviation<2.32%), and good accuracy (the relative differences compared to a reference method was<5.76%). Coupled with the fact that the method is simple, rapid, and accurate, it is suitable for a variety of applications that call for the analysis of high carbonate content in paper samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Authentication of pineapple (Ananas comosus [L.] Merr.) fruit maturity stages by quantitative analysis of γ- and δ-lactones using headspace solid-phase microextraction and chirospecific gas chromatography-selected ion monitoring mass spectrometry (HS-SPME-GC-SIM-MS).

    PubMed

    Steingass, Christof B; Langen, Johannes; Carle, Reinhold; Schmarr, Hans-Georg

    2015-02-01

    Headspace solid phase microextraction and chirospecific gas chromatography-mass spectrometry in selected ion monitoring mode (HS-SPME-GC-SIM-MS) allowed quantitative determination of δ-lactones (δ-C8, δ-C10) and γ-lactones (γ-C6, γ-C8, γ-C10). A stable isotope dilution assay (SIDA) with d7-γ-decalactone as internal standard was used for quantitative analysis of pineapple lactones that was performed at three progressing post-harvest stages of fully ripe air-freighted and green-ripe sea-freighted fruits, covering the relevant shelf-life of the fruits. Fresh pineapples harvested at full maturity were characterised by γ-C6 of high enantiomeric purity remaining stable during the whole post-harvest period. In contrast, the enantiomeric purity of γ-C6 significantly decreased during post-harvest storage of sea-freighted pineapples. The biogenetical background and the potential of chirospecific analysis of lactones for authentication and quality evaluation of fresh pineapple fruits are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Analysis of endogenous aldehydes in human urine by static headspace gas chromatography-mass spectrometry.

    PubMed

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2016-03-11

    Endogenous aldehydes (EAs) generated during oxidative stress and cell processes are associated with many pathogenic and toxicogenic processes. The aim of this research was to develop a solvent-free and automated analytical method for the determination of EAs in human urine using a static headspace generator sampler coupled with gas chromatography-mass spectrometry (HS-GC-MS). Twelve significant EAs used as markers of different biochemical and physiological processes, namely short- and medium-chain alkanals, α,β-unsaturated aldehydes and dicarbonyl aldehydes have been selected as target analytes. Human urine samples (no dilution is required) were derivatized with O-2,3,4,5,6-pentafluorobenzylhydroxylamine in alkaline medium (hydrogen carbonate-carbonate buffer, pH 10.3). The HS-GC-MS method developed renders an efficient tool for the sensitive and precise determination of EAs in human urine with limits of detection from 1 to 15ng/L and relative standard deviations, (RSDs) from 6.0 to 7.9%. Average recoveries by enriching urine samples ranged between 92 and 95%. Aldehydes were readily determined at 0.005-50μg/L levels in human urine from healthy subjects, smokers and diabetic adults. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    PubMed

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  12. Determination of the content of alkyl ketene dimer in its latex by an ionic-liquid assisted headspace gas chromatography.

    PubMed

    Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan; Chen, Chun-Xia

    2017-12-29

    This paper reports on an ionic-liquid assisted headspace gas chromatographic (HS-GC) for the determination of the content of alkyl ketene dimer (AKD) in its latex samples, in which the GC system was equipped with a thermal conductivity detector (TCD). The method was based on the AKD hydrolysis conducted in 1-butyl-3-methylimidazolium chloride (ionic-liquid) added medium at 100°C for 10min in a closed headspace sample vial, and the measured CO 2 (the resulting product of the hydrolysis) by HS-GC. The results showed that the present method has a good measurement precision (RSD <2.3%) and accuracy (recoveries from 96 - 105%), and the limit of quantitation (LOQ) is 0.9%. The present method is very suitable to be used for the routine check of AKD content in its latex sample in mill applications. The study also showed that the content of AKD in the tested commercial latex samples were in the range of 3.5-12%. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Characterization of volatile profile from ten different varieties of Chinese jujubes by HS-SPME/GC-MS coupled with E-nose.

    PubMed

    Chen, Qinqin; Song, Jianxin; Bi, Jinfeng; Meng, Xianjun; Wu, Xinye

    2018-03-01

    Volatile profile of ten different varieties of fresh jujubes was characterized by HS-SPME/GC-MS (headspace solid phase micro-extraction combined with gas chromatography-mass spectrometry) and E-nose (electronic nose). GC-MS results showed that a total of 51 aroma compounds were identified in jujubes, hexanoic acid, hexanal, (E)-2-hexenal, (Z)-2-heptenal, benzaldehyde and (E)-2-nonenal were the main aroma components with contributions that over 70%. Differentiation of jujube varieties was conducted by cluster analysis of GC-MS data and principal component analysis & linear discriminant analysis of E-nose data. Both results showed that jujubes could be mainly divided into two groups: group A (JZ, PDDZ, JSXZ and LWZZ) and group B (BZ, YZ, MZ, XZ and DZ). There were significant differences in contents of alcohols, acids and aromatic compounds between group A and B. GC-MS coupled with E-nose could be a fast and accurate method to identify the general flavor difference in different varieties of jujubes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Evaluation of injection methods for fast, high peak capacity separations with low thermal mass gas chromatography.

    PubMed

    Fitz, Brian D; Mannion, Brandyn C; To, Khang; Hoac, Trinh; Synovec, Robert E

    2015-05-01

    Low thermal mass gas chromatography (LTM-GC) was evaluated for rapid, high peak capacity separations with three injection methods: liquid, headspace solid phase micro-extraction (HS-SPME), and direct vapor. An Agilent LTM equipped with a short microbore capillary column was operated at a column heating rate of 250 °C/min to produce a 60s separation. Two sets of experiments were conducted in parallel to characterize the instrumental platform. First, the three injection methods were performed in conjunction with in-house built high-speed cryo-focusing injection (HSCFI) to cryogenically trap and re-inject the analytes onto the LTM-GC column in a narrower band. Next, the three injection methods were performed natively with LTM-GC. Using HSCFI, the peak capacity of a separation of 50 nl of a 73 component liquid test mixture was 270, which was 23% higher than without HSCFI. Similar peak capacity gains were obtained when using the HSCFI with HS-SPME (25%), and even greater with vapor injection (56%). For the 100 μl vapor sample injected without HSCFI, the preconcentration factor, defined as the ratio of the maximum concentration of the detected analyte peak relative to the analyte concentration injected with the syringe, was determined to be 11 for the earliest eluting peak (most volatile analyte). In contrast, the preconcentration factor for the earliest eluting peak using HSCFI was 103. Therefore, LTM-GC is demonstrated to natively provide in situ analyte trapping, although not to as great an extent as with HSCFI. We also report the use of LTM-GC applied with time-of-flight mass spectrometry (TOFMS) detection for rapid, high peak capacity separations from SPME sampled banana peel headspace. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. High-throughput analysis of bergamot essential oil by fast solid-phase microextraction-capillary gas chromatography-flame ionization detection.

    PubMed

    Tranchida, Peter Quinto; Presti, Maria Lo; Costa, Rosaria; Dugo, Paola; Dugo, Giovanni; Mondello, Luigi

    2006-01-20

    The advantages of using a narrow-bore column in headspace solid-phase microextraction-gas chromatographic (HS-SPME-GC) analysis are investigated. An automated rapid HS-SPME-GC method for the determination of volatile compounds in a complex sample (bergamot essential oil) was developed. A low-capacity (7 microm) SPME fibre was employed, enabling a short equilibration time (15 min). The absorbed volatile compounds were then separated in 12.5 min on a 10 m x 0.1 mm I.D. capillary. The fast GC method was characterized by relatively moderate GC parameters (head pressure: 173 kPa; temperature program rate: 12 degrees C/min). The employment of the low-capacity fibre also suited the reduced sample capacity of the capillary employed, hence column overloading was avoided. Analytical repeatibility was determined in terms of retention times (maximum RSD: 0.32%) and peak areas (maximum RSD: 9.80%). The results obtained were compared to those derived from a conventional HS-SPME-GC (a 30 microm SPME fibre and 0.25 mm I.D. capillary were used) application on the same sample. In this respect, a great reduction of analytical time was obtained both with regard to the conventional SPME equilibration and GC run times, which both required 50 min. Peak resolution was altogether comparable in both applications. Although a slight loss in terms of sensitivity was observed in the rapid approach (generally within the 25-50% range), this did not impair the detection of all peaks of interest. Finally, the selectivities of the 30 and 7 microm fibres were evaluated and, as expected, these were in good agreement.

  16. Determination of cannabinoids in hemp food products by use of headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Lachenmeier, Dirk W; Kroener, Lars; Musshoff, Frank; Madea, Burkhard

    2004-01-01

    A fully automated procedure using alkaline hydrolysis and headspace solid-phase microextraction (HS-SPME), followed by on-fiber derivatization and gas chromatographic-mass spectrometric (GC-MS) detection has been developed for determination of cannabinoids in hemp food samples. After addition of a deuterated internal standard, the sample was hydrolyzed with sodium hydroxide and submitted to direct HS-SPME. After absorption of analytes for on-fiber derivatization, the fiber was placed directly into the headspace of a second vial containing N-methyl- N-trimethylsilyltrifluoroacetamide (MSTFA), before GC-MS analysis. Linearity was good for Delta(9)-tetrahydrocannabinol (THC), cannabidiol, and cannabinol; regression coefficients were greater than 0.99. Depending on the characteristics of the matrix the detection limits obtained ranged between 0.01 and 0.17 mg kg(-1) and the precision between 0.4 and 11.8%. In comparison with conventional liquid-liquid extraction this automated HS-SPME-GC-MS procedure is substantially faster. It is easy to perform, solvent-free, and sample quantities are minimal, yet it maintains the same sensitivity and reproducibility. The applicability was demonstrated by analysis of 30 hemp food samples. Cannabinoids were detected in all of the samples and it was possible to differentiate between drug-type and fiber-type Cannabis sativa L. In comparison with other studies relatively low THC concentrations between 0.01 and 15.53 mg kg(-1) were determined.

  17. Measurement of the isotope ratio of acetic acid in vinegar by HS-SPME-GC-TC/C-IRMS.

    PubMed

    Hattori, Ryota; Yamada, Keita; Shibata, Hiroki; Hirano, Satoshi; Tajima, Osamu; Yoshida, Naohiro

    2010-06-23

    Acetic acid is the main ingredient of vinegar, and the worth of vinegar often depends on the fermentation of raw materials. In this study, we have developed a simple and rapid method for discriminating the fermentation of the raw materials of vinegar by measuring the hydrogen and carbon isotope ratio of acetic acid using head space solid-phase microextraction (HS-SPME) combined with gas chromatography-high temperature conversion or combustion-isotope ratio mass spectrometry (GC-TC/C-IRMS). The measurement of acetic acid in vinegar by this method was possible with repeatabilities (1sigma) of +/-5.0 per thousand for hydrogen and +/-0.4 per thousand for carbon, which are sufficient to discriminate the origin of acetic acid. The fermentation of raw materials of several vinegars was evaluated by this method.

  18. Blood monitoring of perfluorocarbon compounds (F-tert-butylcyclohexane, perfluoromethyldecalin and perfluorodecalin) by headspace-gas chromatography-tandem mass spectrometry.

    PubMed

    Giuliani, N; Saugy, M; Augsburger, M; Varlet, V

    2015-11-01

    A headspace-gas chromatography-tandem mass spectrometry (HS-GC-MS/MS) method for the trace measurement of perfluorocarbon compounds (PFCs) in blood was developed. Due to oxygen carrying capabilities of PFCs, application to doping and sports misuse is speculated. This study was therefore extended to perform validation methods for F-tert-butylcyclohexane (Oxycyte(®)), perfluoro(methyldecalin) (PFMD) and perfluorodecalin (PFD). The limit of detection of these compounds was established and found to be 1.2 µg/mL blood for F-tert-butylcyclohexane, 4.9 µg/mL blood for PFMD and 9.6 µg/mL blood for PFD. The limit of quantification was assumed to be 12 µg/mL blood (F-tert-butylcyclohexane), 48 µg/mL blood (PFMD) and 96 µg/mL blood (PFD). HS-GC-MS/MS technique allows detection from 1000 to 10,000 times lower than the estimated required dose to ensure a biological effect for the investigated PFCs. Thus, this technique could be used to identify a PFC misuse several hours, maybe days, after the injection or the sporting event. Clinical trials with those compounds are still required to evaluate the validation parameters with the calculated estimations. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Improvement of a headspace solid phase microextraction-gas chromatography/mass spectrometry method for the analysis of wheat bread volatile compounds.

    PubMed

    Raffo, Antonio; Carcea, Marina; Castagna, Claudia; Magrì, Andrea

    2015-08-07

    An improved method based on headspace solid phase microextraction combined with gas chromatography-mass spectrometry (HS-SPME/GC-MS) was proposed for the semi-quantitative determination of wheat bread volatile compounds isolated from both whole slice and crust samples. A DVB/CAR/PDMS fibre was used to extract volatiles from the headspace of a bread powdered sample dispersed in a sodium chloride (20%) aqueous solution and kept for 60min at 50°C under controlled stirring. Thirty-nine out of all the extracted volatiles were fully identified, whereas for 95 other volatiles a tentative identification was proposed, to give a complete as possible profile of wheat bread volatile compounds. The use of an array of ten structurally and physicochemically similar internal standards allowed to markedly improve method precision with respect to previous HS-SPME/GC-MS methods for bread volatiles. Good linearity of the method was verified for a selection of volatiles from several chemical groups by calibration with matrix-matched extraction solutions. This simple, rapid, precise and sensitive method could represent a valuable tool to obtain semi-quantitative information when investigating the influence of technological factors on volatiles formation in wheat bread and other bakery products. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Quantitative Determination of Acetaldehyde in Foods Using Automated Digestion with Simulated Gastric Fluid Followed by Headspace Gas Chromatography

    PubMed Central

    Uebelacker, Michael; Lachenmeier, Dirk W.

    2011-01-01

    Acetaldehyde (ethanal) is a genotoxic carcinogen, which may occur naturally or as an added flavour in foods. We have developed an efficient method to analyze the compound in a wide variety of food matrices. The analysis is conducted using headspace (HS) gas chromatography (GC) with flame ionization detector. Using a robot autosampler, the samples are digested in full automation with simulated gastric fluid (1 h at 37°C) under shaking, which frees acetaldehyde loosely bound to matrix compounds. Afterwards, an aliquot of the HS is injected into the GC system. Standard addition was applied for quantification to compensate for matrix effects. The precision of the method was sufficient (<3% coefficient of variation). The limit of detection was 0.01 mg/L and the limit of quantification was 0.04 mg/L. 140 authentic samples were analyzed. The acetaldehyde content in apples was 0.97 ± 0.80 mg/kg, orange juice contained 3.86 ± 2.88 mg/kg. The highest concentration was determined in a yoghurt (17 mg/kg). A first-exposure estimation resulted in a daily acetaldehyde intake of less than 0.1 mg/kg bodyweight from food, which is considerably lower than the exposures from alcohol consumption or tobacco smoking. PMID:21747735

  1. Sensitive determination of four general anaesthetics in human whole blood by capillary gas chromatography with cryogenic oven trapping.

    PubMed

    Kojima, T; Ishii, A; Watanabe-Suzuki, K; Kurihara, R; Seno, H; Kumazawa, T; Suzuki, O; Katsumata, Y

    2001-10-05

    Four general anaesthetics, sevoflurane, isoflurane, enflurane and halothane, in human whole blood, have been found measurable with very high sensitivity by capillary gas chromatography-flame ionization detection (GC-FID) with cryogenic oven trapping upon injection of headspace (HS) vapor sample. To a 7-ml vial, containing 0.48 ml of distilled water and 20 microl of internal standard solution (5 microg), a 0.5-ml of whole blood sample spiked with or without anaesthetics, was added, and the mixture was heated at 55 degrees C for 15 min. A measure of 10 ml HS vapor was injected into the GC in the splitless mode at -40 degrees C oven temperature, which was programmed up to 250 degrees C. All four peaks were clearly separated; no impurity peaks were found among their peaks. Their extraction efficiencies were about 10%. The calibration curves showed good linearity in the range of 0.5-20 microg/ml; their detection limits were 10-100 ng/ml, which are almost comparable to those by previous reports. The coefficients of intra-day and day-to-day variations were 6.5-9.8 and 7.3-17.2%, respectively. Isoflurane or enflurane was also measured from whole blood samples in which three volunteers inhaled each compound.

  2. Comparative evaluation of liquid-liquid extraction, solid-phase extraction and solid-phase microextraction for the gas chromatography-mass spectrometry determination of multiclass priority organic contaminants in wastewater.

    PubMed

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2013-12-15

    The European Water Framework Directive (WFD) 2000/60/EC establishes guidelines to control the pollution of surface water by sorting out a list of priority substances that involves a significant risk to or via the aquatic systems. In this article, the analytical performance of three different sample preparation methodologies for the GC-MS/MS determination of multiclass organic contaminants-including priority comprounds from the WFD-in wastewater samples using gas chromatography-mass spectrometry was evaluated. The methodologies tested were: (a) liquid-liquid extraction (LLE) with n-hexane; (b) solid-phase extraction (SPE) with C18 cartridges and elution with ethyl acetate:dichloromethane (1:1 (v/v)), and (c) headspace solid-phase microextraction (HS-SPME) using two different fibers: polyacrylate and polydimethylsiloxane/carboxen/divinilbenzene. Identification and confirmation of the selected 57 compounds included in the study (comprising polycyclic aromatic hydrocarbons (PAHs), pesticides and other contaminants) were accomplished using gas chromatography tandem mass spectrometry (GC-MS/MS) with a triple quadrupole instrument operated in the multiple reaction monitoring (MRM) mode. Three MS/MS transitions were selected for unambiguous confirmation of the target chemicals. The different advantages and pitfalls of each method were discussed. In the case of both LLE and SPE procedures, the method was validated at two different concentration levels (15 and 150 ng L(-1)) obtaining recovery rates in the range 70-120% for most of the target compounds. In terms of analyte coverage, results with HS-SPME were not satisfactory, since 14 of the compounds tested were not properly recovered and the overall performance was worse than the other two methods tested. LLE, SPE and HS-SPME (using polyacrylate fiber) procedures also showed good linearity and precision. Using any of the three methodologies tested, limits of quantitation obtained for most of the detected compounds were in the low nanogram per liter range. © 2013 Elsevier B.V. All rights reserved.

  3. Identification of volatile compounds associated with the aroma of white strawberries (Fragaria chiloensis).

    PubMed

    Prat, Loreto; Espinoza, María Inés; Agosin, Eduardo; Silva, Herman

    2014-03-15

    Fragaria chiloensis (L.) Mill spp. chiloensis form chiloensis, is a strawberry that produces white fruits with unique aromas. This species, endemic to Chile, is one of the progenitors of Fragaria x ananassa Duch. In order to identify the volatile compounds that might be responsible for aroma, these were extracted, and analyzed by gas chromatography-mass spectrometry (GC-MS), gas chromatography-olfactometry (GC-O) and compared with sensory analyses. Three methods of extraction were used: solvent-assisted evaporation (SAFE), headspace solid phase micro-extraction (HS-SPME) and liquid-liquid extraction (LLE). Ninety-nine volatile compounds were identified by GC-MS, of which 75 showed odor activity using GC-O. Based on the highest dilution factor (FD = 1000) and GC-O intensity ≥2, we determined 20 major compounds in white strawberry fruit that contribute to its aroma. We chose 51 compounds to be tested against their commercial standards. The identities were confirmed by comparison of their linear retention indices against the commercial standards. The aroma of white strawberry fruits was reconstituted with a synthetic mixture of most of these compounds. The volatile profile of white strawberry fruit described as fruity, green-fresh, floral, caramel, sweet, nutty and woody will be a useful reference for future strawberry breeding programs. © 2013 Society of Chemical Industry.

  4. Magnetic solid phase extraction and static headspace gas chromatography-mass spectrometry method for the analysis of polycyclic aromatic hydrocarbons.

    PubMed

    Cai, Ying; Yan, Zhihong; Wang, Lijia; NguyenVan, Manh; Cai, Qingyun

    2016-01-15

    A magnetic solid phase extraction (MSPE) protocol combining a static headspace gas chromatography coupled to mass spectrometry (HS-GC-MS) method has been developed for extraction, and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in drinking water samples. Magnetic nanoparticles (MNPs) were coated with 3-aminopropyltriethoxysilane and modified by cholesterol chloroformate. Transmission electron microscope, vibrating sample magnetometer, Fourier transform infrared spectrometry and X-ray photoelectron spectroscopy were used to characterize the cholesterol-functionalized sorbents, and the main parameters affecting the extraction as well as HS sampling, such as sorbent amount, extraction time, oven temperature and equilibration time have been investigated and established. Combination with HS sampling, the MSPE procedure was simple, fast and environmentally friendly, without need of any organic solvent. Method validation proved the feasibility of the developed sorbents for the quantitation of the investigated analytes at trace levels obtaining the limit of detection (S/N=3) ranging from 0.20 to 7.8 ng/L. Good values for intra and inter-day precision were obtained (RSDs ≤ 9.9%). The proposed method was successfully applied to drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Development of gas chromatographic methods for the analyses of organic carbonate-based electrolytes

    NASA Astrophysics Data System (ADS)

    Terborg, Lydia; Weber, Sascha; Passerini, Stefano; Winter, Martin; Karst, Uwe; Nowak, Sascha

    2014-01-01

    In this work, novel methods based on gas chromatography (GC) for the investigation of common organic carbonate-based electrolyte systems are presented, which are used in lithium ion batteries. The methods were developed for flame ionization detection (FID), mass spectrometric detection (MS). Further, headspace (HS) sampling for the investigation of solid samples like electrodes is reported. Limits of detection are reported for FID. Finally, the developed methods were applied to the electrolyte system of commercially available lithium ion batteries as well as on in-house assembled cells.

  6. Rapid Monitoring of Pharmacological Volatiles of Night-Flowering Evening-Primrose According to Flower Opening or Closing by Fast Gas Chromatography/Surface Acoustic Wave Sensor (Electronic zNose).

    PubMed

    Oh, Se Yeon

    2018-05-01

    Aroma is important in night-flowering species, as visually they can not be observed well. Thus, the analysis of the volatiles of evening-primrose is of great interest in biological fields and therapy. Furthermore, the analysis of volatiles demands rapid and simple procedure, because volatiles decompose. The aim of this study is to show the rapid monitoring of the volatiles of evening-primrose according to the flowering or closing by fast gas chromatography/surface acoustic wave GC/SAW. Moreover, calibration according to the sensor temperature of the GC/SAW was performed, achieving a high reproducibility and excellent sensitivity. GC/SAW is an effective analytical method that provides on-line measurements without pretreatment of sample. Headspace solid-phase micro-extraction coupled to gas chromatography mass spectrometry (HS-SPME-GC-MS) and dynamic headspace trapping and extraction with GC-MS were employed to confirm the identification of the volatiles of evening-primrose compared to GC/SAW. Linalool was found to be the dominant component, comprising 96.4-25.2% of the total amount, according to the opening or closing. Interestingly, the amount of indole also varied according to the opening or closing (3.0-0.0%) such as linalool. Also, while the sensitivity increased with the reduction in the sensor temperature of the GC/SAW, the reproducibility showed a tendency to decrease. The results showed that flower opening is related to the volatiles emission, which is pharmacological and plant defensive. GC/SAW can be a useful analytical method for the rapid monitoring of volatiles of evening-primrose according to the opening or closing as it provides second unit analysis, as well as simple, and aroma pattern recognition. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Characterization of aroma compounds in apple cider using solvent-assisted flavor evaporation and headspace solid-phase microextraction.

    PubMed

    Xu, Yan; Fan, Wenlai; Qian, Michael C

    2007-04-18

    The aroma-active compounds in two apple ciders were identified using gas chromatography-olfactometry (GC-O) and GC-mass spectrometry (MS) techniques. The volatile compounds were extracted using solvent-assisted flavor evaporation (SAFE) and headspace solid-phase microextraction (HS-SPME). On the basis of odor intensity, the most important aroma compounds in the two apple cider samples were 2-phenylethanol, butanoic acid, octanoic acid, 2-methylbutanoic acid, 2-phenylethyl acetate, ethyl 2-methylbutanoate, ethyl butanoate, ethyl hexanoate, 4-ethylguaiacol, eugenol, and 4-vinylphenol. Sulfur-containing compounds, terpene derivatives, and lactones were also detected in ciders. Although most of the aroma compounds were common in both ciders, the aroma intensities were different. Comparison of extraction techniques showed that the SAFE technique had a higher recovery for acids and hydroxy-containing compounds, whereas the HS-SPME technique had a higher recovery for esters and highly volatile compounds.

  8. [Analyze on volatile compounds of Antrodia camphorata using HS-SPME-GC-MS].

    PubMed

    He, Zhe; Lu, Zhen-Ming; Xu, Hong-Yu; Shi, Jing-Song; Xu, Zheng-Hong

    2011-11-01

    To analyze the volatile compounds of Antrodia camphorata in solid-state and submerged cultures. A headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry(GC-MS) were used to evaluate the profile of the volatile compounds. 49 volatile compounds were identified in A. camphorata mycelia in submerged culture, while 43 volatile compounds were identified in mycelia in solid-state culture. 1-octen-3-ol, 3-octanone, 1-octen-3-ylacetate, acetic acid octyl ester and ethanol were the main volatile compounds in A. camphorata mycelia in submerged culture, while 1-octen-3-ol, 3-octanone, 3-methyl-butyraldenhyde, gamma-podecalactone and methyl 2-furozte were the most potent key volatile compounds in mycelia in solid-state culture. The volatile compounds in the mycelia of A. camphorata in solid-state and submerged cultures are similar but their relative contents are different.

  9. Optimization of HS-SPME/GC-MS analysis and its use in the profiling of illicit ecstasy tablets (Part 1).

    PubMed

    Bonadio, Federica; Margot, Pierre; Delémont, Olivier; Esseiva, Pierre

    2009-05-30

    A headspace solid-phase microextraction procedure (HS-SPME) was developed for the profiling of traces present in 3,4-methylenedioxymethylampethamine (MDMA). Traces were first extracted using HS-SPME and then analyzed by gas chromatography-mass spectroscopy (GC-MS). The HS-SPME conditions were optimized using varying conditions. Optimal results were obtained when 40 mg of crushed MDMA sample was heated at 80 degrees C for 15 min, followed by extraction at 80 degrees C for 15 min with a polydimethylsiloxane/divinylbenzene coated fibre. A total of 31 compounds were identified as traces related to MDMA synthesis, namely precursors, intermediates or by-products. In addition some fatty acids used as tabletting materials and caffeine used as adulterant, were also detected. The use of a restricted set of 10 target compounds was also proposed for developing a screening tool for clustering samples having close profile. 114 seizures were analyzed using an SPME auto-sampler (MultiPurpose Samples MPS2), purchased from Gerstel GMBH & Co. (Germany), and coupled to GC-MS. The data was handled using various pre-treatment methods, followed by the study of similarities between sample pairs based on the Pearson correlation. The results show that HS-SPME, coupled with the suitable statistical method is a powerful tool for distinguishing specimens coming from the same seizure and specimens coming from different seizures. This information can be used by law enforcement personnel to visualize the ecstasy distribution network as well as the clandestine tablet manufacturing.

  10. Rapid method for determination of carbonyl groups in lignin compounds by headspace gas chromatography.

    PubMed

    Li, Jing; Hu, Hui-Chao; Chai, Xin-Sheng

    2015-07-24

    The paper reports on a novel method for rapid determination of carbonyl in lignins by headspace gas chromatography (HS-GC). The method involves the quantitative carbonyl reduction for aldehydes in 2min at room temperature or for acetones in 30min at 80°C by sodium borohydride solution in a closed headspace sample vial. After the reaction, the solution was acidified by injecting sulfuric acid solution and the hydrogen released to the headspace was determined by GC using thermal-conductivity detector. The results showed that with the addition of SiO2 powder, the reduction reaction of carbonyl groups can be greatly facilitated. The method has a good measurement precision (RSD<7.74%) and accuracy (relative error <10% compared with a reference method) in the carbonyl quantification. It is suitable to be used for rapid determination of carbonyl content in lignin and related materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Ripening-dependent metabolic changes in the volatiles of pineapple (Ananas comosus (L.) Merr.) fruit: I. Characterization of pineapple aroma compounds by comprehensive two-dimensional gas chromatography-mass spectrometry.

    PubMed

    Steingass, Christof Björn; Carle, Reinhold; Schmarr, Hans-Georg

    2015-03-01

    Qualitative ripening-dependent changes of pineapple volatiles were studied via headspace solid-phase microextraction and analyzed by comprehensive two-dimensional gas chromatography quadrupole mass spectrometry (HS-SPME-GC×GC-qMS). Early green-ripe stage, post-harvest ripened, and green-ripe fruits at the end of their commercial shelf-life were compared to air-freighted pineapples harvested at full maturity. In total, more than 290 volatiles could be identified by mass spectrometry and their linear retention indices. The majority of compounds comprise esters (methyl and ethyl esters of saturated and unsaturated fatty acids, acetates), terpenes, alcohols, aldehydes, 2-ketones, free fatty acids, and miscellaneous γ- and δ-lactones. The structured separation space obtained by GC×GC allowed revealing various homologous series of compound classes as well as clustering of sesquiterpenes. Post-harvest ripening increased the diversity of the volatile profile compared to both early green-ripe maturity stages and on-plant ripened fruits.

  12. Headspace solid-phase microextraction (HS-SPME) and liquid-liquid extraction (LLE): comparison of the performance in classification of ecstasy tablets. Part 2.

    PubMed

    Bonadio, Federica; Margot, Pierre; Delémont, Olivier; Esseiva, Pierre

    2008-11-20

    Headspace solid-phase microextraction (HS-SPME) is assessed as an alternative to liquid-liquid extraction (LLE) currently used for 3,4-methylenedioxymethampethamine (MDMA) profiling. Both methods were compared evaluating their performance in discriminating and classifying samples. For this purpose 62 different seizures were analysed using both extraction techniques followed by gas chromatography-mass spectroscopy (GC-MS). A previously validated method provided data for HS-SPME, whereas LLE data were collected applying a harmonized methodology developed and used in the European project CHAMP. After suitable pre-treatment, similarities between sample pairs were studied using the Pearson correlation. Both methods enable to distinguish between samples coming from the same pre-tabletting batches and samples coming from different pre-tabletting batches. This finding emphasizes the use of HS-SPME as an effective alternative to LLE, with additional advantages such as sample preparation and a solvent-free process.

  13. Assessment of dispersive liquid-liquid microextraction conditions for gas chromatography time-of-flight mass spectrometry identification of organic compounds in honey.

    PubMed

    Moniruzzaman, M; Rodríguez, I; Rodríguez-Cabo, T; Cela, R; Sulaiman, S A; Gan, S H

    2014-11-14

    The suitability of the dispersive liquid-liquid microextraction (DLLME) technique for gas chromatography (GC) characterization of minor organic compounds in honey samples is evaluated. Under optimized conditions, samples were pre-treated by liquid-liquid extraction with acetonitrile followed by DLLME using carbon tetrachloride (CCl4, 0.075 mL) as extractant. The yielded settled phase was analyzed by GC using high resolution time-of-flight (TOF) mass spectrometry (MS). The whole sample preparation process is completed in approximately 10 min, with a total consumption of organic solvents below 4 mL, relative standard deviations lower than 12% and with more than 70 organic compounds, displaying linear retention index in the range from 990 to 2900, identified in the obtained extracts. In comparison with HS SPME extraction, higher peak intensities were attained for most volatile and semi-volatile compounds amenable to both extraction techniques. Furthermore, other species such as highly polar and water soluble benzene acids, long chain fatty acids, esters and flavonoids, which are difficult to concentrate by HS SPME, could be identified in DLLME extracts. Some of the compounds identified in DLLME extracts have been proposed as useful for samples classification and/or they are recognized as markers of honeys from certain geographic areas. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Simultaneous determination of traces of pyrethroids, organochlorines and other main plant protection agents in agricultural soils by headspace solid-phase microextraction-gas chromatography.

    PubMed

    Fernandez-Alvarez, Maria; Llompart, Maria; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Cela, Rafael; Dagnac, Thierry

    2008-04-25

    A solvent-free and simple method based on headspace solid-phase microextraction (HS-SPME) was developed in order to determine simultaneously 36 common pesticides and breakdown products (mostly pyrethroids and organochlorine compounds) in soil. The analysis was carried out by gas chromatography with micro-electron-capture detection (GC-microECD). As far as we know, this is the first study about the SPME of pyrethroid insecticides from soil. Factors such as extraction temperature, matrix modification by addition of water, salt addition (% NaCl) and fiber coating were considered in the optimization of the HS-SPME. To this end, a 3 x 2(3-1) fractional factorial design was performed. The results showed that temperature and fiber coating were the most significant variables affecting extraction efficiency. A suitable sensitivity for all investigated compounds was achieved at 100 degrees C by extracting soil samples wetted with 0.5 mL of ultrapure water (0% NaCl) employing a polyacrylate (PA) coating fiber. Using the recommended extraction conditions with GC-microECD, a linear calibration could be achieved over a range of two orders of magnitude for both groups of analytes. Limits of detection (LODS) at the sub-ng g(-1) level were attained and relative standard deviations (RSDs) were found to be lower than 14% for both groups of pesticides. Matrix effects were investigated by the analysis of different soil samples fortified with the target compounds. The method accuracy was assessed and good recovery values (>70%, in most cases) were obtained. The method was also validated with a certified reference material (RTC-CRM818-050), which was quantified using a standard addition protocol. Finally, the proposed HS-SPME-GC-microECD methodology was further applied to the screening of environmental soil samples for the presence of the target pesticides.

  15. Analysis of fatty acid ethyl esters in hair as possible markers of chronically elevated alcohol consumption by headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Pragst, F; Auwaerter, V; Sporkert, F; Spiegel, K

    2001-09-15

    Fatty acid ethyl esters (FAEE) are products of the nonoxidative ethanol metabolism, which are known to be detectable in blood only about 24h after the last alcohol intake. After deposition in hair they should be suitable long-term markers of chronically elevated alcohol consumption. Therefore, a method for the analysis of ethyl myristate, ethyl palmitate, ethyl oleate and ethyl stearate from hair was developed based on the extraction of the hair sample by a dimethylsulphoxide (DMSO)/n-hexane mixture, separation and evaporation of the n-hexane phase and application of headspace solid-phase microextraction (HS-SPME) in combination with gas chromatography-mass spectrometry (GC-MS) to the extract. For use as internal standards, the corresponding D(5)-ethyl esters were prepared. The HS-SPME/GC-MS measurements were automatically performed using a multi-purpose sampler. The detection limits of the FAEE were between 0.01 and 0.04ng/mg and the reproducibility was between 3.5 and 16%. By application of the method to hair samples of 21 fatalities with known heavy alcohol abuse 0.045-2.4ng/mg ethyl myristate, 0.35-13.5ng/mg ethyl palmitate, 0.25-7.7ng/mg ethyl oleate and 0.05-3.85ng/mg ethyl stearate were measured. For social drinkers (30-60g ethanol per week), the concentrations were about one order of magnitude smaller. For 10 teetotalers negative results or traces of ethyl palmitate were found. It was shown by supplementary investigations in single cases that FAEE are also present in sebum, that there is no strong difference in their concentrations between pubic, chest and scalp hair, and that they are detectable in hair segments after a 2 months period of abstinence. From the results follows that the measurement of FAEE concentrations in hair is a useful way for a retrospective detection of alcohol abuse.

  16. Characterization of the volatile components in green tea by IRAE-HS-SPME/GC-MS combined with multivariate analysis.

    PubMed

    Yang, Yan-Qin; Yin, Hong-Xu; Yuan, Hai-Bo; Jiang, Yong-Wen; Dong, Chun-Wang; Deng, Yu-Liang

    2018-01-01

    In the present work, a novel infrared-assisted extraction coupled to headspace solid-phase microextraction (IRAE-HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for rapid determination of the volatile components in green tea. The extraction parameters such as fiber type, sample amount, infrared power, extraction time, and infrared lamp distance were optimized by orthogonal experimental design. Under optimum conditions, a total of 82 volatile compounds in 21 green tea samples from different geographical origins were identified. Compared with classical water-bath heating, the proposed technique has remarkable advantages of considerably reducing the analytical time and high efficiency. In addition, an effective classification of green teas based on their volatile profiles was achieved by partial least square-discriminant analysis (PLS-DA) and hierarchical clustering analysis (HCA). Furthermore, the application of a dual criterion based on the variable importance in the projection (VIP) values of the PLS-DA models and on the category from one-way univariate analysis (ANOVA) allowed the identification of 12 potential volatile markers, which were considered to make the most important contribution to the discrimination of the samples. The results suggest that IRAE-HS-SPME/GC-MS technique combined with multivariate analysis offers a valuable tool to assess geographical traceability of different tea varieties.

  17. Volatile profile analysis and quality prediction of Longjing tea (Camellia sinensis) by HS-SPME/GC-MS

    PubMed Central

    Lin, Jie; Dai, Yi; Guo, Ya-nan; Xu, Hai-rong; Wang, Xiao-chang

    2012-01-01

    This study aimed to analyze the volatile chemical profile of Longjing tea, and further develop a prediction model for aroma quality of Longjing tea based on potent odorants. A total of 21 Longjing samples were analyzed by headspace solid phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS). Pearson’s linear correlation analysis and partial least square (PLS) regression were applied to investigate the relationship between sensory aroma scores and the volatile compounds. Results showed that 60 volatile compounds could be commonly detected in this famous green tea. Terpenes and esters were two major groups characterized, representing 33.89% and 15.53% of the total peak area respectively. Ten compounds were determined to contribute significantly to the perceived aroma quality of Longjing tea, especially linalool (0.701), nonanal (0.738), (Z)-3-hexenyl hexanoate (−0.785), and β-ionone (−0.763). On the basis of these 10 compounds, a model (correlation coefficient of 89.4% and cross-validated correlation coefficient of 80.4%) was constructed to predict the aroma quality of Longjing tea. Summarily, this study has provided a novel option for quality prediction of green tea based on HS-SPME/GC-MS technique. PMID:23225852

  18. Characterization of the volatile components in green tea by IRAE-HS-SPME/GC-MS combined with multivariate analysis

    PubMed Central

    Yin, Hong-Xu; Yuan, Hai-Bo; Jiang, Yong-Wen; Dong, Chun-Wang; Deng, Yu-Liang

    2018-01-01

    In the present work, a novel infrared-assisted extraction coupled to headspace solid-phase microextraction (IRAE-HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for rapid determination of the volatile components in green tea. The extraction parameters such as fiber type, sample amount, infrared power, extraction time, and infrared lamp distance were optimized by orthogonal experimental design. Under optimum conditions, a total of 82 volatile compounds in 21 green tea samples from different geographical origins were identified. Compared with classical water-bath heating, the proposed technique has remarkable advantages of considerably reducing the analytical time and high efficiency. In addition, an effective classification of green teas based on their volatile profiles was achieved by partial least square-discriminant analysis (PLS-DA) and hierarchical clustering analysis (HCA). Furthermore, the application of a dual criterion based on the variable importance in the projection (VIP) values of the PLS-DA models and on the category from one-way univariate analysis (ANOVA) allowed the identification of 12 potential volatile markers, which were considered to make the most important contribution to the discrimination of the samples. The results suggest that IRAE-HS-SPME/GC-MS technique combined with multivariate analysis offers a valuable tool to assess geographical traceability of different tea varieties. PMID:29494626

  19. Determination of volatile organic acids in oriental tobacco by needle-based derivatization headspace liquid-phase microextraction coupled to gas chromatography/mass spectrometry.

    PubMed

    Sun, Shi-Hao; Xie, Jian-Ping; Xie, Fu-Wei; Zong, Yong-Li

    2008-02-01

    A method coupling needle-based derivatization headspace liquid-phase microextraction with gas chromatography-mass spectrometry (HS-LPME/GC-MS) was developed to determine volatile organic acids in tobacco. The mixture of N,O-bis(trimethylsilyl)trifluoroacetamide and decane was utilized as the solvent for HS-LPME, resulting that extraction and derivatization were simultaneously completed in one step. The solvent served two purposes. First, it pre-concentrated volatile organic acids in the headspace of tobacco sample. Second, the volatile organic acids extracted were derivatized to form silyl derivatives in the drop. The main parameters affecting needle-based derivatization HS-LPME procedure such as extraction and derivatization reagent, microdrop volume, extraction and derivatization time, and preheating temperature and preheating time were optimized. The standard addition approach was essential to obtain accurate measurements by minimizing matrix effects. Good linearity (R(2)> or =0.9804) and good repeatability (RSDs< or =15.3%, n=5) for 16 analytes in spiked standard analytes sample were achieved. The method has the additional advantages that at the same time it is simple, fast, effective, sensitive, selective, and provides an overall profile of volatile organic acids in the oriental tobacco. This paper does offer an alternative approach to determine volatile organic acids in tobacco.

  20. A comparison study on a sulfonated graphene-polyaniline nanocomposite coated fiber for analysis of nicotine in solid samples through the traditional and vacuum-assisted HS-SPME.

    PubMed

    Ghiasvand, Alireza; Koonani, Samira; Yazdankhah, Fatemeh; Farhadi, Saeid

    2018-02-05

    A simple, rapid, and reliable headspace solid-phase microextraction (HS-SPME) procedure, reinforced by applying vacuum in the extraction vial, was developed. It was applied for the extraction of nicotine in solid samples prior to determination by gas chromatography-flame ionization detection (GC-FID). First, the surface of a narrow stainless steel wire was made porous and adhesive by platinization to obtain a durable, higher surface area, and resistant fiber. Then, a thin film of sulfonated graphene/polyaniline (Sulf-G/PANI) nanocomposite was synthesized and simultaneously coated on the platinized fiber using the electrophoretic deposition (EPD) method. It was demonstrated that the extraction efficiency remarkably increased by applying the reduced-pressure condition in the extraction vial. To evaluate the conventional HS-SPME and vacuum-assisted HS-SPME (VA-HS-SPME) platforms, all experimental parameters affecting the extraction efficiency including desorption time and temperature, extraction time and temperature and moisture content of sample matrix were optimized. The highest extraction efficiency was obtained at 60°C, 10min (extraction temperature and time) and 280°C, 2min (desorption condition), for VA-HS-SPME strategy, while for conventional HS-SPME the extraction and desorption conditions found to be 100°C, 30min and 280°C, 2min, respectively. The Sulf-G/PANI coated fiber showed high thermal stability, good chemical/mechanical resistance, and long lifetime. For analysis of nicotine in solid samples using VA-HS-SPME-GC-FID, linear dynamic range (LDR) was 0.01-30μgg -1 (R 2 =0.996), the relative standard deviation (RSD%, n=6), for analyses of 1μgg -1 nicotine was calculated 3.4% and limit of detection (LOD) found to be 0.002μgg -1 . The VA-HS-SPME-GC-FID strategy was successfully carried out for quantitation of nicotine in hair and tobacco real samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Volatile Compounds from the Different Organs of Houttuynia cordata and Litsea cubeba (L. citriodora).

    PubMed

    Asakawa, Yoshinori; Tomiyama, Kenichi; Sakurai, Kazutoshi; Kawakami, Yukihiro; Yaguchi, Yoshihiro

    2017-08-01

    The volatile compounds obtained from the different organs of Houttuynia cordata (Saururaceae) and Litsea cubeba (Lauraceae) were analyzed by Gas Chromatography/Mass Spectrometry (GC/MS), Headspace Solid Phase Micro Extraction-Gas Chromatography/Mass Spectrometry (HS-SPME-GC/MS), and GC/olfactometry (GC/O). The major component of all parts of H. cordata is assigned as 4-tridecanone. Each organ produces myrcene as the major monoterpenoid. The major monoterpene in the rhizomes and roots was β-pinene instead of myrcene. 1-Decanal which was responsible for the unpleasant odor of this plant, was the predominant polyketide in both leaves and stems. The presence of 1-decanal was very poor in flowers, stem collected in summer, rhizomes, and roots. GC/MS analyses were very simple in case of the crude extracts of flowers. The content of sesquiterpenoids was extremely poor. (8Z)-Heptadecene, geranial, and neral were detected as the major components in Litsea cubeba. Odor-contributing components by GC/O analysis of the ether extract of the fresh flowers of L. cubeba were neral and geranial which played an important role in sweet-lemon fragrance of the flowers. The role of a high content of (8Z)-heptadecene was still unknown but it might play a significant role in the dispersion of the volatile monoterpene hydrocarbons and aldehydes. The flower volatiles of the Japanese L. cubeba were chemically quite different from those of the Chinese same species.

  2. Characterisation of volatile profiles in 50 native Peruvian chili pepper using solid phase microextraction-gas chromatography mass spectrometry (SPME-GCMS).

    PubMed

    Patel, Kirti; Ruiz, Candy; Calderon, Rosa; Marcelo, Mavel; Rojas, Rosario

    2016-11-01

    The volatiles were characterised by headspace solid phase micro extraction (HS-SPME), gas chromatography mass spectrometry (GC-FID/MS). A total of 127 compounds were identified with terpenes (including mono terpenes and sesquiterpenes - a total of 45 compounds), esters (31 compounds) and hydrocarbons (20 compounds) were the predominant volatile compounds. Principal component analysis (PCA) of the volatile compounds yielded 2 significant PC's, which together accounted for 90.3% of the total variance in the data set and the scatter plot generated between PC1 and PC2 successfully segregated the 50 chili pepper samples into 7 groups. Clusters of hydrocarbons, esters, terpenes, aldehyde and ketones formed the major determinants of the difference. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Freeze-thaw method improves the detection of volatile compounds in insects using Headspace Solid-Phase Microextraction (HS-SPME)

    USDA-ARS?s Scientific Manuscript database

    Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography–mass spectrometry (GC-MS) is commonly used in analyzing insect volatiles. In order to improve the detection of volatiles in insects, a freeze-thaw method was applied to insect samples before the HS-SPME-GC-MS analysis. ...

  4. Quantification of selected volatile organic compounds in human urine by gas chromatography selective reagent ionization time of flight mass spectrometry (GC-SRI-TOF-MS) coupled with head-space solid-phase microextraction (HS-SPME).

    PubMed

    Mochalski, Paweł; Unterkofler, Karl

    2016-08-07

    Selective reagent ionization time of flight mass spectrometry with NO(+) as the reagent ion (SRI-TOF-MS(NO(+))) in conjunction with gas chromatography (GC) and head-space solid-phase microextraction (HS-SPME) was used to determine selected volatile organic compounds in human urine. A total of 16 volatiles exhibiting high incidence rates were quantified in the urine of 19 healthy volunteers. Amongst them there were ten ketones (acetone, 2-butanone, 3-methyl-2-butanone, 2-pentanone, 3-methyl-2-pentanone, 4-methyl-2-pentanone, 2-hexanone, 3-hexanone, 2-heptanone, and 4-heptanone), three volatile sulphur compounds (dimethyl sulfide, allyl methyl sulfide, and methyl propyl sulfide), and three heterocyclic compounds (furan, 2-methylfuran, 3-methylfuran). The concentrations of the species under study varied between 0.55 nmol L(-1) (0.05 nmol mmol(-1)creatinine) for allyl methyl sulfide and 11.6 μmol L(-1) (1.54 μmol mmol(-1)creatinine) for acetone considering medians. Limits of detection (LODs) ranged from 0.08 nmol L(-1) for allyl methyl sulfide to 1.0 nmol L(-1) for acetone and furan (with RSDs ranging from 5 to 9%). The presented experimental setup assists both real-time and GC analyses of volatile organic compounds, which can be performed consecutively using the same analytical system. Such an approach supports the novel concept of hybrid volatolomics, an approach which combines VOC profiles obtained from two or more body fluids to improve and complement the chemical information on the physiological status of an individual.

  5. Use of ionic liquids as headspace gas chromatography diluents for the analysis of residual solvents in pharmaceuticals.

    PubMed

    Nacham, Omprakash; Ho, Tien D; Anderson, Jared L; Webster, Gregory K

    2017-10-25

    In this study, two ionic liquids (ILs), 1-butyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([BMIM][NTf 2 ]) and trihexyltetradecylphosphonium bis[(trifluoromethyl)sulfonyl]imide ([P 66614 ][NTf 2 ]) were examined as contemporary diluents for residual solvent analysis using static headspace gas chromatography (SHS-GC) coupled with flame ionization detection (FID). ILs are a class of non-molecular solvents featuring negligible vapor pressure and high thermal stabilities. Owing to these favorable properties, ILs have potential to enable superior sensitivity and reduced interference, compared to conventional organic diluents, at high headspace incubation temperatures. By employing the [BMIM][NTf 2 ] IL as a diluent, a 25-fold improvement in limit of detection (LOD) was observed with respect to traditional HS-GC diluents, such as N-methylpyrrolidone (NMP). The established IL-based method demonstrated LODs ranging from 5.8 parts-per-million (ppm) to 20ppm of residual solvents in drug substances. The optimization of headspace extraction conditions was performed prior to method validation. An incubation temperature of 140°C and a 15min incubation time provided the best sensitivity for the analysis. Under optimized experimental conditions, the mass of residual solvents partitioned in the headspace was higher when using [BMIM][NTf 2 ] than NMP as a diluent. The analytical performance was demonstrated by determining the repeatability, accuracy, and linearity of the method. Linear ranges of up to two orders of magnitude were obtained for class 3 solvents. Excellent analyte recoveries were obtained in the presence of three different active pharmaceutical ingredients. Owing to its robustness, high throughput, and superior sensitivity, the HS-GC IL-based method can be used as an alternative to existing residual solvent methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Direct determination of acrylamide in potato chips by using headspace solid-phase microextraction coupled with gas chromatography-flame ionization detection.

    PubMed

    Ghiasvand, Ali Reza; Hajipour, Somayeh

    2016-01-01

    Acrylamide is a potentially toxic and carcinogenic substance present in many high-consumption foods. Recently, this matter has been placed in category of "reasonably anticipated to be a human carcinogen" by National Toxicology Program (NTP). Therefore, simple and cost-effective determination of acrylamide in food samples has attracted intense interest. The most reported techniques for this purpose are GC-MS and LC-MS, which are very expensive and available in few laboratories. In this research, for the first time, a rapid, easy and low-cost method is introduced for sensitive and precise determination of acrylamide in foodstuffs, using gas chromatography-flame ionization detection (GC-FID) system after its direct trapping in the upper atmosphere of samples by headspace solid-phase microextraction (HS-SPME). The effects of main experimental variables were studied and the optimized parameters were obtained as the type of fiber, carboxen/divinylbenzene/polydimethylsiloxane (CAR/DVB/PDMS); extraction time, 30 min; extraction temperature, 60°C; moisture content, 10 µL water per 1g of sample; desorption time, 2 min; and desorption temperature, 230°C. The linear calibration graph was obtained in the range of 0.77-50 µg g(-1), with regression coefficient of 0.998. The detection and quantification limits of the proposed method were 0.22 and 0.77 µg g(-1), respectively. The recoveries, for different food samples, were 79.6-95.7%. The repeatability of measurements, expressed as relative standard deviation (RSD), were found to be 4.1-8.0% (n=9). The proposed HS-SPME-GC-FID method was successfully carried out for quantifying of trace levels of acrylamide in some processed food products (chips and French fries), sold in open local markets. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Development of water-phase derivatization followed by solid-phase microextraction and gas chromatography/mass spectrometry for fast determination of valproic acid in human plasma.

    PubMed

    Deng, Chunhui; Li, Ning; Ji, Jie; Yang, Bei; Duan, Gengli; Zhang, Xiangmin

    2006-01-01

    In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids. Copyright 2006 John Wiley & Sons, Ltd.

  8. Formation of complex natural flavours by biotransformation of apple pomace with basidiomycetes.

    PubMed

    Bosse, Andrea K; Fraatz, Marco A; Zorn, Holger

    2013-12-01

    Altogether 30 different basidiomycetes were grown submerged in liquid culture media using seven different by-products of the food industry as the only carbon source. Seven fungus/substrate combinations revealed interesting flavour profiles. Culture supernatants of Tyromyces chioneus grown on apple pomace were extracted, and the aroma compounds were analysed by gas chromatography-olfactometry (GC-O). Potent odorants were identified by aroma extract dilution analysis (AEDA), calculation of the odour activity values (OAV), and proven by confection of an aroma model. 3-Phenylpropanal, 3-phenyl-1-propanol, and benzyl alcohol were identified as potent aroma biotransformation products. Headspace solid-phase microextraction gas chromatography mass spectrometry (HS-SPME-GC-MS) experiments showed that 3-phenylpropanal, 3-phenyl-1-propanol, benzyl alcohol, methyl 3-phenylpropionate, methyl 2-phenylacetate, cinnamaldehyde and methyl cinnamate were produced during the cultivation period of eight days. By means of labelling experiments, (E)-cinnamic acid was identified as the precursor of 3-phenylpropanal and 3-phenyl-1-propanol. Basidiomycetes were able to biotransform food by-products to pleasant complex flavour mixtures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Inline roasting hyphenated with gas chromatography-mass spectrometry as an innovative approach for assessment of cocoa fermentation quality and aroma formation potential.

    PubMed

    Van Durme, Jim; Ingels, Isabel; De Winne, Ann

    2016-08-15

    Today, the cocoa industry is in great need of faster and robust analytical techniques to objectively assess incoming cocoa quality. In this work, inline roasting hyphenated with a cooled injection system coupled to a gas chromatograph-mass spectrometer (ILR-CIS-GC-MS) has been explored for the first time to assess fermentation quality and/or overall aroma formation potential of cocoa. This innovative approach resulted in the in-situ formation of relevant cocoa aroma compounds. After comparison with data obtained by headspace solid phase micro extraction (HS-SPME-GC-MS) on conventional roasted cocoa beans, ILR-CIS-GC-MS data on unroasted cocoa beans showed similar formation trends of important cocoa aroma markers as a function of fermentation quality. The latter approach only requires small aliquots of unroasted cocoa beans, can be automatated, requires no sample preparation, needs relatively short analytical times (<1h) and is highly reproducible. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Ethanol concentration in 56 refillable electronic cigarettes liquid formulations determined by headspace gas chromatography with flame ionization detector (HS-GC-FID).

    PubMed

    Poklis, Justin L; Wolf, Carl E; Peace, Michelle R

    2017-10-01

    Personal battery-powered vaporizers or electronic cigarettes were developed as an alternative to traditional cigarettes. The modern electronic cigarettes were patented in 2004 by Hon Lik in China. In May 2016, the US Food and Drug Administration (FDA) imposed regulatory statutes on e-cigarettes and their liquid formulations (e-liquids); prior to that, they were unregulated. E-liquids are typically composed of propylene glycol and/or glycerin, flavouring component(s), and active ingredient(s), such as nicotine. Fifty-six commercially available e-liquids, purchased from various sources, contained a variety of flavours and active ingredients. A headspace gas chromatography with flame ionization detector (HS-GC-FID) method was used to analyze these e-liquids for volatiles content. Only one of the e-liquids listed ethanol as a component. The chromatographic separation of volatiles was performed on a Restek BAC-1 column. A linear calibration was generated for ethanol with limits of detection and quantification (LOD/LOQ) of 0.05 mg/mL. Ethanol concentrations in the 56 e-liquids ranged from none detected to 206 mg/mL. The ethanol determined in these products may have been used in flavourants or a solvent; the reason for inclusion cannot be fully ascertained. The implications of vaporizing ethanol as an e-liquid component are unknown. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  11. HS-SPME determination of volatile carbonyl and carboxylic compounds in different matrices.

    PubMed

    Stashenko, Elena E; Mora, Amanda L; Cervantes, Martha E; Martínez, Jairo R

    2006-07-01

    Specific chromatographic methodologies are developed for the analysis of carboxylic acids (C(2)-C(6), benzoic) and aldehydes (C(2)-C(10)) of low molecular weight in diverse matrices, such as air, automotive exhaust gases, human breath, and aqueous matrices. For carboxylic acids, the method is based on their reaction with pentafluorobenzyl bromide in aqueous solution, followed by the separation and identification of the resultant pentafluorobenzyl esters by means of headspace (HS)-solid-phase microextraction (SPME) combined with gas chromatography (GC) and electron capture detection (ECD). Detection limits in the microg/m(3) range are reached, with relative standard deviation (RSD) less than 10% and linear response (R(2) > 0.99) over two orders of magnitude. The analytical methodology for aldehydes is based on SPME with simultaneous derivatization of the analytes on the fiber, by reaction with pentafluorophenylhydrazine. The derivatization reagent is previously deposited on the SPME fiber, which is then exposed to the gaseous matrix or the HS of the sample solution. The pentafluorophenyl hydrazones formed on the fiber are analyzed selectively by means of GC-ECD, with detection limits in the ng/m(3) range, RSD less than 10%, and linear response (R(2) > 0.99) over two orders of magnitude.

  12. Sol-gel-based SPME fiber as a reliable sampling technique for studying biogenic volatile organic compounds released from Clostridium tetani.

    PubMed

    Ghader, Masoud; Shokoufi, Nader; Es-Haghi, Ali; Kargosha, Kazem

    2017-11-01

    A novel and efficient headspace solid-phase microextraction (HS-SPME) method, followed by gas chromatography mass spectrometry (GC-MS), was developed to study volatile organic compounds (VOCs) emerging from microorganisms. Two homemade SPME fibers, a semi-polar poly (dimethylsiloxane) (PDMS) fiber, and a polar polyethylene glycol (PEG) fiber, along with two commercial fibers (PDMS and PDMS/DVB) were used to collect VOCs emerging from Clostridium tetani which was cultured in different media. The adsorbed VOCs were desorbed and identified, in vitro, using GC-MS. The adsorption efficiency was improved by optimizing the time duration of adsorption and desorption. About 50 components were identified by the proposed method. The main detected compounds appeared to be sulfur containing compounds such as butanethioic acid S-methyl ester, dimethyl trisulfide, and dimethyl tetrasulfide. These volatile sulfur containing compounds are derived from amino acids containing the sulfur element, which probably coexist in the mentioned bacterium or are added to the culture media. The developed HS-SPME-GC-MS method allowed the determination of the chemical fingerprint of Clostridium tetani volatile constituents, and thus provides a new, simple, and reliable tool for studying the growth of microorganisms. Graphical abstract Investigation of biogenic VOCs released from Clostridium tetani using SPME-GC-MS.

  13. Identification of volatiles in leaves of Alpinia zerumbet 'Variegata' using headspace solid-phase microextraction-gas chromatography-mass spectrometry.

    PubMed

    Chen, Jian Yan; Ye, Zheng Mei; Huang, Tian Yi; Chen, Xiao Dan; Li, Yong Yu; Wu, Shao Hua

    2014-07-01

    Alpinia zerumbet 'Variegata' is an aromatic medicinal plant, its foliage producing an intense, unique fragrant odor. This study identified 46 volatile compounds in the leaf tissue of this plant using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). The major compounds included 1, 8-cineole (43.5%), p-cymene (14.7%), humulene (5.5%), camphor (5.3%), linalool (4.7%), (E)-methyl cinnamate (3.8%), gamma-cadinene (3.3%), humulene oxide II (2.1%) and a-terpineol (1.5%). The majority of the volatiles were terpenoids of which oxygenated monoterpenes were the most abundant, accounting for 57.2% of the total volatiles. Alcohols made up the largest (52.8%) and aldehydes the smallest (0.2%) portions of the volatiles. Many bioactive compounds were present in the volatiles.

  14. Determination of the volatile and semi-volatile secondary metabolites, and aristolochic acids in Aristolochia ringens Vahl.

    PubMed

    Stashenko, Elena E; Andrés Ordóñez, Sergio; Marín, Néstor Armando; Martínez, Jairo René

    2009-10-01

    Volatile and semi-volatile secondary metabolites, as well as aristolochic acids (AA), present in leaves, stems, and flowers of Aristolochia ringens were determined by gas chromatography (GC)-mass spectrometry (MS) and high-performance liquid chromatography (HPLC) methods, respectively. Metabolite isolation was performed using different extraction techniques: microwave-assisted hydrodistillation (MWHD), supercritical fluid extraction, and headspace solid-phase microextraction (HS-SPME). The chemical composition of the extracts and oils was established by GC-MS. The determinations of AAI and AAII were conducted by methanolic extraction of different plant parts followed by HPLC analysis. Essential oil yields from leaves and stems were 0.008 +/- 0.0022% and 0.047 +/- 0.0026%, respectively. Aristolochia ringens flowers did not yield essential oil under MWHD. Sesquiterpene hydrocarbons (66%) were the main compounds in the essential oil isolated from leaves whereas monoterpene hydrocarbons (73%) predominated in the stems essential oil. Yields of extracts isolated by SFE from leaves, stems, and flowers were 4 +/- 1.8%, 1.2 +/- 0.25%, and 4 +/- 1.8%, respectively. In vivo HS-SPME of flowers isolated compounds with known unpleasant smells such as volatile aldehydes and short-chain carboxylic acids. HPLC analysis detected the presence of AAII in the flowers of Aristolochia ringens at a concentration of 610 +/- 47 mg/kg of dried flower.

  15. Application of HS-SPME and GC-MS to characterization of volatile compounds emitted from Osmanthus flowers.

    PubMed

    Deng, Chunhui; Song, Guoxin; Hu, Yaoming

    2004-12-01

    Headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-mass spectrometry (GC-MS) was developed for characterization of volatile compounds emitted from two varieties Osmanthus flowers of O. fragrans var. latifolius and O. fragrans var. thunbergii. The SPME parameters were studied, the optimum conditions of a 65 microm carbowax/divinylbenzene (CW/DVB), extraction temperature of 22 degrees C and extraction time of 10 min were obtained and applied to extraction of the volatile emissions. Fourteen compounds released from both varieties of Osmanthus flowers were separated and identified by GC-MS, which mainly included alpha-linalool, beta-linalool, trans-linalool oxide, cis-linalool oxide, alpha-lonone, beta-lonone, capraldehyde and decalactone. By comparing their peak areas, we found that the sums of the fourteen compounds from the two Osmanthus flowers were very close, while the relative contents of individual volatile compounds in the two emissions were very different. The relative content of alpha-linalool and beta-linalool in O. fragrans var. latifolius were 39.46% and 0.51%, while in O. fragrans var. thunbergii were 9.53% and 27.71%. Due to their different relative contents, the two varieties of flower have different fragrances.

  16. Comparison of the atmospheric- and reduced-pressure HS-SPME strategies for analysis of residual solvents in commercial antibiotics using a steel fiber coated with a multiwalled carbon nanotube/polyaniline nanocomposite.

    PubMed

    Ghiasvand, Ali Reza; Nouriasl, Kolsoum; Yazdankhah, Fatemeh

    2018-01-01

    A low-cost, sensitive and reliable reduced-pressure headspace solid-phase microextraction (HS-SPME) setup was developed and evaluated for direct extraction of residual solvents in commercial antibiotics, followed by determination by gas chromatography with flame ionization detection (GC-FID). A stainless steel narrow wire was made porous and adhesive by platinization by a modified electrophoretic deposition method and coated with a polyaniline/multiwalled carbon nanotube nanocomposite. All experimental variables affecting the extraction efficiency were investigated for both atmospheric-pressure and reduced-pressure conditions. Comparison of the optimal experimental conditions and the results demonstrated that the reduced-pressure strategy leads to a remarkable increase in the extraction efficiency and reduction of the extraction time and temperature (10 min, 25 °Ϲ vs 20 min, 40 °Ϲ). Additionally, the reduced-pressure strategy showed better analytical performances compared with those obtained by the conventional HS-SPME-GC-FID method. Limit of detections, linear dynamic ranges, and relative standard deviations of the reduced-pressure HS-SPME procedure for benzene, toluene, ethylbenzene, and xylene (BTEX) in injectable solid drugs were obtained over the ranges of 20-100 pg g -1 , 0.02-40 μg g -1 , and 2.8-10.2%, respectively. The procedure developed was successful for the analysis of BTEX in commercial containers of penicillin, ampicillin, ceftriaxone, and cefazolin. Graphical abstract Schematic representation of the developed RP-HS-SPME setup.

  17. Diesel Engine Air Emissions Reduction Technologies

    DTIC Science & Technology

    2010-04-01

    Hour GC/MS Gas Chromatography /Mass Spectroscopy GC/FID Gas Chromatography /Flame Ionization Detector g/mile Gram per Mile HAP Hazardous Air...Pollutant HC Hydrocarbon HPLC/UV High Performance Liquid Chromatography / Ultraviolet KPa Kilo-Pascals NDIR Non Dispersive Infrared... Chromatography (GC) where the samples were collected on DNPH cartridges. Portable versions of these instruments were available and employed for

  18. Static headspace gas chromatography-mass spectrometry for the one-step derivatisation and extraction of eleven aldehydes in drinking water.

    PubMed

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2013-09-13

    Low-molecular-mass aldehydes (LMMAs) are water disinfection by-products formed by the reaction of ozone and/or chlorine with natural organic matter in water. LMMAs are mutagenic and carcinogenic compounds, which are detected at ng/L levels in water. An analytical method that allows simultaneous derivatisation and extraction of LMMAs in water has been developed using the classical static headspace technique coupled with gas chromatography-mass spectrometry (HS-GC-MS). Important parameters controlling the derivatisation of LMMAs with o-2,3,4,5,6-pentafluorobenzylhydroxylamine, oxime-products extraction and headspace generation were optimised to obtain the highest sensitivity, completing the entire process in 20min. For the first time the derivatisation reaction was carried out at alkaline pH adjusted with sodium hydrogen carbonate which exerts a significant enhancement effect on the derivatisation efficiency of the aldehydes; up to 20-fold with respect to those obtained in weak acid media as recommended by EPA Method 556.1. The addition of 200μL of n-hexane, as a chemical modifier, favoured the volatilisation of oxime-products, increasing the sensitivity of the method. The proposed method allows the achieving of detection limits from 2 to 80ng/L and has excellent precision (RSD average value of 6.4%) and accuracy (recovery ranging from 97% to 99%) for LMMA quantifications in drinking water samples. Finally, the HS-GC-MS method was validated relative to EPA Method 556.1 for the analysis of drinking water samples subjected to several disinfection treatments. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Differentiation of South American crack and domestic (US) crack cocaine via headspace-gas chromatography/mass spectrometry.

    PubMed

    Colley, Valerie L; Casale, John F

    2015-03-01

    South American 'crack' cocaine, produced directly from coca leaf, can be distinguished from US domestically produced crack on the basis of occluded solvent profiles. In addition, analysis of domestically produced crack indicates the solvents that were used for cocaine hydrochloride (HCl) processing in South America. Samples of cocaine base (N=3) from South America and cocaine from the USA (N=157 base, N=88 HCl) were analyzed by headspace-gas chromatography-mass spectrometry (HS-GC-MS) to determine their solvent profiles. Each cocaine HCl sample was then converted to crack cocaine using the traditional crack production method and re-examined by HS-GC-MS. The resulting occluded solvent profiles were then compared to their original HCl solvent profiles. Analysis of the corresponding crack samples confirmed the same primary processing solvents found in the original HCl samples, but at reduced levels. Domestically seized crack samples also contained reduced levels of base-to-HCl conversion solvents. In contrast, analysis of South American crack samples confirmed the presence of low to high boiling hydrocarbons and no base-to-HCl conversion solvents. The presented study showed analysis of crack cocaine samples provides data on which processing solvents were originally utilized in the production of cocaine HCl in South America, prior to conversion to crack cocaine. Determination of processing solvents provides valuable information to the counter-drug intelligence community and assists the law enforcement community in determining cocaine distribution and trafficking routes throughout the world. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  20. Development and Validation of a Method for Alcohol Analysis in Brain Tissue by Headspace Gas Chromatography with Flame Ionization Detector

    PubMed Central

    Chun, Hao-Jung; Poklis, Justin L.; Poklis, Alphonse; Wolf, Carl E.

    2016-01-01

    Ethanol is the most widely used and abused drug. While blood is the preferred specimen for analysis, tissue specimens such as brain serve as alternative specimens for alcohol analysis in post-mortem cases where blood is unavailable or contaminated. A method was developed using headspace gas chromatography with flame ionization detection (HS-GC-FID) for the detection and quantification of ethanol, acetone, isopropanol, methanol and n-propanol in brain tissue specimens. Unfixed volatile-free brain tissue specimens were obtained from the Department of Pathology at Virginia Commonwealth University. Calibrators and controls were prepared from 4-fold diluted homogenates of these brain tissue specimens, and were analyzed using t-butanol as the internal standard. The chromatographic separation was performed with a Restek BAC2 column. A linear calibration was generated for all analytes (mean r2 > 0.9992) with the limits of detection and quantification of 100–110 mg/kg. Matrix effect from the brain tissue was determined by comparing the slopes of matrix prepared calibration curves with those of aqueous calibration curves; no significant differences were observed for ethanol, acetone, isopropanol, methanol and n-propanol. The bias and the CVs for all volatile controls were ≤10%. The method was also evaluated for carryover, selectivity, interferences, bench-top stability and freeze-thaw stability. The HS-GC-FID method was determined to be reliable and robust for the analysis of ethanol, acetone, isopropanol, methanol and n-propanol concentrations in brain tissue, effectively expanding the specimen options for post-mortem alcohol analysis. PMID:27488829

  1. Study of the aroma formation and transformation during the manufacturing process of oolong tea by solid-phase micro-extraction and gas chromatography-mass spectrometry combined with chemometrics.

    PubMed

    Ma, Chengying; Li, Junxing; Chen, Wei; Wang, Wenwen; Qi, Dandan; Pang, Shi; Miao, Aiqing

    2018-06-01

    Oolong tea is a typical semi-fermented tea and is famous for its unique aroma. The aim of this study was to compare the volatile compounds during manufacturing process to reveal the formation of aroma. In this paper, a method was developed based on head-space solid phase microextraction/gas chromatography-mass spectrometry (HS-SPME/GC-MS) combined with chemometrics to assess volatile profiles during manufacturing process (fresh leaves, sun-withered leaves, rocked leaves and leaves after de-enzyming). A total of 24 aroma compounds showing significant differences during manufacturing process were identified. Subsequently, according to these aroma compounds, principal component analysis and hierarchical cluster analysis showed that the four samples were clearly distinguished from each other, which suggested that the 24 identified volatile compounds can represent the changes of volatile compounds during the four steps. Additionally, sun-withering, rocking and de-enzyming can influence the variations of volatile compounds in different degree, and we found the changes of volatile compounds in withering step were less than other two manufacturing process, indicating that the characteristic volatile compounds of oolong tea might be mainly formed in rocking stage by biological reactions and de-enzyming stage through thermal chemical transformations rather than withering stage. This study suggested that HS-SPME/GC-MS combined with chemometrics methods is accurate, sensitive, fast and ideal for rapid routine analysis of the aroma compounds changes in oolong teas during manufacturing processing. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Determination of isocyanate groups in the organic intermediates by reaction-based headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Chai, Xin-Sheng

    2016-10-14

    This work reports on a novel method for the determination of isocyanate groups in the related organic intermediates by a reaction-based headspace gas chromatography. The method is based on measuring the CO 2 formed from the reaction between the isocyanate groups in the organic intermediates and water in a closed headspace sample vial at 45°C for 20min. The results showed that the method has a good precision and accuracy, in which the relative standard deviation in the repeatability measurement was 5.26%, and the relative differences between the data obtained by the HS-GC method and the reference back-titration method were within 9.42%. The present method is simple and efficient and is particularly suitable to be used for determining the isocyanate groups in the batch sample analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Pedologic Factors Affecting Virgin Olive Oil Quality of "Chemlali" Olive Trees (Olea europaea L.).

    PubMed

    Rached, Mouna Ben; Galaverna, Gianni; Cirlini, Martina; Boujneh, Dalenda; Zarrouk, Mokhtar; Guerfel, Mokhtar

    2017-08-01

    The aim of this study examined the characterization of extra virgin olive oil samples from the main cultivar Chemlali, grown in five olive orchards with different soil type (Sandy, Clay, Stony, Brown, Limestone and Gypsum). Volatile compounds were studied using headspace-solid phase micro-extraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) technics. Moreover, the sterol profile was established using gas chromatography-mass spectrometry. 35 different volatile compounds were identified: alcohols, esters, aldehydes, ketones and hydrocarbons. The chemical composition of the volatile fraction was characterized by the preeminence of 2-hexenal (32.75%) and 1-hexanol (31.88%). Three sterols were identified and characterized. For all olive oil samples, ß-sitosterol (302.25 mg/kg) was the most abundant sterol. Interestingly, our results showed significant qualitative and quantitative differences in the levels of the volatile compounds and sterols from oils obtained from olive trees grown in different soil type.

  4. Accurate determination of residual acrylic acid in superabsorbent polymer of hygiene products by headspace gas chromatography.

    PubMed

    Zhang, Shu-Xin; Chai, Xin-Sheng; Jiang, Ran

    2017-02-17

    This work reports on a method for the determination of residual acrylic acid (AA) in the superabsorbent polymers for hygiene products by headspace analysis. It was based on water extraction for the polymer sample at a room temperature for 50min. Then, the AA in the extractant reacted with bicarbonate solution in a closed headspace sample vial, from which the carbon dioxide generated from the reaction (within 20min at 70°C) was detected by gas chromatography (GC). It was found that there is adsorption partition equilibrium of AA between solid-liquid phases. Therefore, an equation for calculating the total AA content in the original polymers sample was derived based on the above phase equilibrium. The results show that the HS-GC method has good precision (RSD<2.51%) and good accuracy (recoveries from 93 to 105%); the limit of quantification (LOQ) was 373mg/kg. The present method is rapid, accurate, and suitable for determining total residual acrylic acid in a wide variety of applications from processing of superabsorbent polymer to commercial products quality control. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Effect of hot air drying on volatile compounds of Flammulina velutipes detected by HS-SPME-GC-MS and electronic nose.

    PubMed

    Yang, Wenjian; Yu, Jie; Pei, Fei; Mariga, Alfred Mugambi; Ma, Ning; Fang, Yong; Hu, Qiuhui

    2016-04-01

    Volatile compounds are important factors that affect the flavor quality of Flammulina velutipes, but the changes occurring during hot air drying is still unclear. To clarify the dynamic changes of flavor components during hot air drying, comprehensive flavor characterization and volatile compounds of F. velutipes were evaluated using electronic nose technology and headspace solid phase micro-extraction combined with gas chromatography-mass spectrometry (HS-SPME-GC-MS), respectively. Results showed that volatile components in F. velutipes significantly changed during hot air drying according to the principal component analysis and radar fingerprint chart of electronic nose. Volatile compounds of fresh F. velutipes consisted mainly of ketones, aldehydes and alcohols, and 3-octanone was the dominant compound. Drying process could significantly decrease the relative content of ketones and promoted the generation of alcohols, acids, and esters, which became the main volatile compounds of dried F. velutipes. These may provide a theoretical basis for the formation mechanism of flavor substances in dried F. velutipes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Study of aroma formation and transformation during the manufacturing process of Biluochun green tea in Yunnan Province by HS-SPME and GC-MS.

    PubMed

    Wang, Chen; Lv, Shidong; Wu, Yuanshuang; Lian, Ming; Gao, Xuemei; Meng, Qingxiong

    2016-10-01

    Biluochun is a typical non-fermented tea and is also famous for its unique aroma in China. Few studies have been performed to evaluate the effect of the manufacturing process on the formation and content of its aroma. The volatile components were extracted at different manufacturing process steps of Biluochun green tea using fully automated headspace solid-phase microextraction (HS-SPME) and further characterised by gas chromatography-mass spectrometry (GC-MS). Among 67 volatile components collected, the fractions of linalool oxides, β-ionone, phenylacetaldehyde, aldehydes, ketones, and nitrogen compounds were increased while alcohols and hydrocarbons declined during the manufacturing process. The aroma compounds decreased the most during the drying steps. We identified a number of significantly changed components that can be used as markers and quality control during the producing process of Biluochun. The drying step played a major role in the aroma formation of green tea products and should be the most important step for quality control. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  7. Rapid evaluation technique to differentiate mushroom disease-related moulds by detecting microbial volatile organic compounds using HS-SPME-GC-MS.

    PubMed

    Radványi, Dalma; Gere, Attila; Jókai, Zsuzsa; Fodor, Péter

    2015-01-01

    Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was used to analyse microbial volatile organic compounds (MVOCs) of mushroom disease-related microorganisms. Mycogone perniciosa, Lecanicillum fungicola var. fungicola, and Trichoderma aggressivum f. europaeum species, which are typically harmful in mushroom cultivation, were examined, and Agaricus bisporus (bisporic button mushroom) was also examined as a control. For internal standard, a mixture of alkanes was used; these were introduced as the memory effect of primed septa in the vial seal. Several different marker compounds were found in each sample, which enabled us to distinguish the different moulds and the mushroom mycelium from each other. Monitoring of marker compounds enabled us to investigate the behaviour of moulds. The records of the temporal pattern changes were used to produce partial least squares regression (PLS-R) models that enabled determination of the exact time of contamination (the infection time of the media). Using these evaluation techniques, the presence of mushroom disease-related fungi can be easily detected and monitored via their emitted MVOCs.

  8. A new approach for the carbon monoxide (CO) exposure diagnosis: measurement of total CO in human blood versus carboxyhemoglobin (HbCO).

    PubMed

    Varlet, Vincent; De Croutte, Emma Lagroy; Augsburger, Marc; Mangin, Patrice

    2013-07-01

    The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning. © 2013 American Academy of Forensic Sciences.

  9. Volatile emerging contaminants in melon fruits, analysed by HS-SPME-GC-MS.

    PubMed

    Cincotta, Fabrizio; Verzera, Antonella; Tripodi, Gianluca; Condurso, Concetta

    2018-03-01

    The aim of this research was to develop and validate a headspace-solid phase micro-extraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) method for the determination of volatile emerging contaminants in fruit. The method showed good precision (RSD ≤ 14%) and satisfactory recoveries (99.1-101.7%) and LOD and LOQ values ranging between 0.011-0.033 μg kg -1 and 0.037-0.098 μg kg -1 , respectively. The method was applied to investigate the content of volatile emerging contaminants in two varieties of melon fruit (Cucumis melo L.) cultivated adjoining high-risk areas. Glycol ethers, BHT, BHA and BTEX (benzene, toluene, ethylbenzene and xylene) were determined in melon fruit pulps for the first time, with different sensitivities depending on sample and variety. Although the amount of the volatile contaminants in the melon samples were in the order of µg kg -1 , the safety of vegetable crops cultivated near risk areas should be more widely considered. The results showed that this accurate and reproducible method can be useful for routine safety control of fruits and vegetables.

  10. Determination of Lactones in Wines by Headspace Solid-Phase Microextraction and Gas Chromatography Coupled with Mass Spectrometry

    PubMed Central

    Pérez-Olivero, S. J.; Pérez-Pont, M. L.; Conde, J. E.; Pérez-Trujillo, J. P.

    2014-01-01

    Application of headspace solid-phase microextraction (HS-SPME) coupled with high-resolution gas chromatographic (HRGC) analysis was studied for determining lactones in wines. Six different SPME fibers were tested, and the influence of different factors such as temperature and time of desorption, ionic strength, time of extraction, content of sugar, ethanol, tannins and anthocyanins, and pH and influence of SO2 were studied. The proposed HS-SPME-GC method is an appropriate technique for the quantitative analysis of γ-butyrolactone, γ-hexalactone, trans-whiskey lactone, γ-octalactone, cis-whiskey lactone, γ-nonalactone, γ-decalactone, δ-decalactone, and γ-undecalactone in wines. Method reproducibility and repeatability ranged between 0.6 and 5.2% for all compounds. Detection limit for γ-butyrolactone was 0.17 mg/L and a few μg/L for the rest of the compounds. The optimized method has been applied to several wine samples. PMID:24782943

  11. Serum levels of organochlorine pesticides in the general population of Thessaly, Greece, determined by HS-SPME GC-MS method.

    PubMed

    Koureas, Michalis; Karagkouni, Foteini; Rakitskii, Valerii; Hadjichristodoulou, Christos; Tsatsakis, Aristidis; Tsakalof, Andreas

    2016-07-01

    In this study, exposure levels of organochlorine pesticides (OCs) were determined in general population residing in Larissa, central Greece. Serum samples from 103 volunteers were analyzed by optimized headspace solid-phase microextraction gas chromatography-mass spectrometry, to detect and quantify OC levels. The most frequently detected analytes were p,p'-DDE (frequency 99%, median:1.25ng/ml) and Hexachlorobenzene (HCB) (frequency 69%, median: 0.13ng/ml). Statistical analysis revealed a significant relationship of p,p'-DDE and HCB levels with age. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Anti-malarial activity and HS-SPME-GC-MS chemical profiling of Plinia cerrocampanensis leaf essential oil

    PubMed Central

    2014-01-01

    Background Plinia cerrocampanensis is an endemic plant of Panama. The leaf essential oil of this plant has shown antibacterial activity. However, anti-malarial activity and chemical profiling by HS-SPME-GC-MS of this essential oil have not been reported before. Methods Anti-malarial activity of the essential oil (EO) was evaluated in vitro against chloroquine-sensitive HB3 and chloroquine-resistant W2 strains of Plasmodium falciparum. Synergistic effect of chloroquine and the EO on parasite growth was evaluated by calculating the combination index. A methodology involving headspace solid phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC-MS) was developed to investigate the composition of Plinia cerrocampanensis EO. Results Plinia cerrocampanensis EO showed a high anti-malarial activity and a synergistic interaction with chloroquine. The Plinia cerrocampanensis EO inhibited P. falciparum growth in vitro at an IC50 of 7.3 μg/mL. Chloroquine together with the EO decreased the IC50 of chloroquine from 0.1 μg/mL to 0.05 μg/mL, and of the EO from 7.3 μg/mL to 1.1 μg/mL. The measured combination index was 0.58, which clearly indicates that the EO acts synergistically with chloroquine. Since the EO maintained its inhibitory activity on the chloroquine-sensitive strain of the parasite, it could be acting by a different mechanism of action than chloroquine. The best HS-SPME-GC-MS analytical conditions were obtained when the temperature of extraction was 49°C, incubation time 14 min, and the time of extraction 10 min. This method allowed for the identification of 53 volatile constituents in the EO, including new compounds not reported earlier. Conclusions The anti-malarial activity exhibited by the Plinia cerrocampanensis EO may lend support for its possible use as an alternative for anti-malarial therapy. PMID:24410874

  13. Gas Chromatography.

    ERIC Educational Resources Information Center

    Cram, Stuart P.; And Others

    1980-01-01

    Selects fundamental developments in theory, methodology, and instrumentation in gas chromatography (GC). A special section reviews GC in the People's Republic of China. Over 1,000 references are cited. (CS)

  14. Automated headspace solid-phase dynamic extraction to analyse the volatile fraction of food matrices.

    PubMed

    Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara

    2004-01-23

    High concentration capacity headspace techniques (headspace solid-phase microextraction (HS-SPME) and headspace sorptive extraction (HSSE)) are a bridge between static and dynamic headspace, since they give high concentration factors as does dynamic headspace (D-HS), and are as easy to apply and as reproducible as static headspace (S-HS). In 2000, Chromtech (Idstein, Germany) introduced an inside-needle technique for vapour and liquid sampling, solid-phase dynamic extraction (SPDE), also known as "the magic needle". In SPDE, analytes are concentrated on a 50 microm film of polydimethylsiloxane (PDMS) and activated carbon (10%) coated onto the inside wall of the stainless steel needle (5 cm) of a 2.5 ml gas tight syringe. When SPDE is used for headspace sampling (HS-SPDE), a fixed volume of the headspace of the sample under investigation is sucked up an appropriate number of times with the gas tight syringe and an analyte amount suitable for a reliable GC or GC-MS analysis accumulates in the polymer coating the needle wall. This article describes the preliminary results of both a study on the optimisation of sampling parameters conditioning HS-SPDE recovery, through the analysis of a standard mixture of highly volatile compounds (beta-pinene, isoamyl acetate and linalool) and of the HS-SPDE-GC-MS analyses of aromatic plants and food matrices. This study shows that HS-SPDE is a successful technique for HS-sampling with high concentration capability, good repeatability and intermediate precision, also when it is compared to HS-SPME.

  15. Determination of glutaraldehyde in water samples by headspace solid-phase microextraction and gas chromatography-mass spectrometry after derivatization with 2,2,2-trifluoroethylhydrazine.

    PubMed

    Kang, Hye-In; Shin, Ho-Sang

    2016-05-27

    A simple and convenient headspace solid-phase microextraction (HS-SPME) gas chromatography mass spectrometry (GC-MS) method was described for the determination of glutaraldehyde in water. Glutaraldehyde in water reacted with 2,2,2-trifluoroethylhydrazine (TFEH) in a headspace vial and the formed TFEH derivatives were vaporized and adsorbed onto a fiber. The optimal HS-SPME conditions were achieved with a 50/30μm-divinylbenzene-carboxen-polydimethylsiloxane fiber, 0.06% 2,2,2-TFEH, 25% salt, an extraction/derivatization temperature of 80°C, a heating time of 30min, and a pH of 6.5. The desorption was performed for 1min at 240°C. Under the established conditions, the lowest limits of detection were 0.3μg/L and 0.1μg/L in 6.0mL of surface water and drinking water, respectively, and the intra- and inter-day relative standard deviation was less than 9.1% at concentrations of 50, 100 and 500μg/L. The calibration curve showed good linearity with R=0.9995 and R=0.9993 in surface water and drinking water, respectively. This method is simple, amenable to automation and environmentally friendly. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Advanced instrumental methods for analyzing organics in solid waste: The use of gas chromatography/matrix isolation infrared spectroscopy (GC/MIIR) and supercritical fluid chromatography (SFC) for waste characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raphaelian, L.A.; Boparai, A.S.; Schneider, J.F.

    1987-01-01

    Objectives of this research project were: (1) to enhance the capabilities of analyzing the complex mixtures found in coal wastes by using gas chromatography/matrix isolation infrared spectroscopy (GC/MIIR); (2) to separate, by supercritical fluid chromatography (SFC), the complex mixtures found in coal wastes into a few, less-complex mixtures so that analysis by gas chromatography (GC/MS) and GC/MIIR would be simplified. Preliminary results are presented for the mass spectra and infrared spectra of xylene isomers, gas chromatogram of 12 C/sub 2/-Napthalenes, averaged IR spectrum and a comparison of matrix isolation with light-pipe infrared spectra. A SFC chromatogram of polynuclear aromatic hydrocarbonsmore » is also presented. 2 refs., 5 figs.« less

  17. COMPARATIVE EVALUATION OF GC/MS (GAS CHROMATOGRAPHY/MASS SPECTROMETRY) DATA ANALYSIS PROCESSING

    EPA Science Inventory

    Mass spectra obtained by fused silica capillary gas chromatography/mass spectrometry/data system (GC/MS/DS) analysis of mixtures of organic chemicals adsorbed on Tenax GC cartridges was subjected to manual and automated interpretative techniques. Synthetic mixtures (85 chemicals ...

  18. A rapid method for simultaneously determining ethanol and methanol content in wines by full evaporation headspace gas chromatography.

    PubMed

    Zhang, Chun-Yun; Lin, Neng-Biao; Chai, Xin-Sheng; Zhong-Li; Barnes, Donald G

    2015-09-15

    This work reports on a full evaporation headspace gas chromatographic (FE HS-GC) method for simultaneously determining the ethanol (EtOH) and methanol (MeOH) content in wines. A small sample (10μL) was placed in a headspace sample vial, and a near-complete mass transfer of ethanol and methanol from the liquid sample to the vapor phase was obtained within three minutes at a temperature of 105°C, which allowed the measurement of the EtOH and MeOH content in the sample by GC. The results showed excellent precision and accuracy, as shown by the reproducibilities of 1.02% and 2.11% for EtOH and MeOH, respectively, and recoveries that ranged from 96.1% to 104% for both alcohols. The method is efficient, accurate and suitable for the determination of EtOH and MeOH in wine production and quality control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Determination of chlorinated volatile organic compounds in polyamine epichlorohydrin solution by headspace gas chromatography.

    PubMed

    Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan

    2017-05-05

    This study demonstrated a headspace gas chromatographic (HS-GC) method for the determination of residual epichlorohydrin (ECH) and the by-product 1,3-dichloro-2-propanol (DCP) in polyamine epichlorohydrin (PAE) solution. It was based on the vapor-liquid phase equilibrium of these analytes at 60°C for 30min in a closed headspace sample vial before GC measurement. It was found that matrix of the PAE solution had the effect on the headspace equilibrium of these species and therefore a standard addition must be applied in the method validation. The results showed that the present method has a good measurement precision (RSD <2.90%) and accuracy (recoveries from 93.6 to 105%), and the limit of quantitation (LOQ) is 3.75mg/L for ECH and 0.8g/L for DCP. The present method is suitable to be used for analyzing the chlorinated volatile organic compounds in the commercial PAE resin solutions. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Simultaneous determination of perfluoroalkyl iodides, perfluoroalkane sulfonamides, fluorotelomer alcohols, fluorotelomer iodides and fluorotelomer acrylates and methacrylates in water and sediments using solid-phase microextraction-gas chromatography/mass spectrometry.

    PubMed

    Bach, Cristina; Boiteux, Virginie; Hemard, Jessica; Colin, Adeline; Rosin, Christophe; Munoz, Jean-François; Dauchy, Xavier

    2016-05-27

    Here, we developed and validated a headspace-solid-phase microextraction-gas chromatography/mass spectrometry (HS-SPME-GC/MS) method for the determination of 14 volatile perfluorinated alkylated substances (PFASs) in water and sediment samples according to SANTE 11945/2015 guidelines. Three fluorotelomer alcohols (FTOHs), two perfluoroalkyl iodides (PFIs), three fluorotelomer iodides (FTIs), four fluorotelomer acrylates and methacrylates (FTACs and FTMACs) and two perfluoroalkyl sulfonamides (FASAs) were analysed simultaneously to assess the occurrence of these compounds from their emission sources to the outlets in water treatment plants. Several SPME parameters were optimised for both water and sediment to maximise responses and keep analysis time to a minimum. In tap water, the limits of quantification (LOQs) were found to be between 20ng/L and 100ng/L depending on the analyte, with mean recoveries ranging from 76 to 126%. For sediments, LOQs ranged from 1 to 3ng/g dry weight depending on the target compound, with mean recoveries ranging from 74 to 125%. SPME considerably reduced sample preparation time and its use provided a sensitive, fast and simple technique. We then used this HS-SPME-GC/MS method to investigate the presence of volatile PFASs in the vicinity of an industrial facility. Only 8:2 FTOH and 10:2 FTOH were detected in a few water and sediment samples at sub-ppb concentration levels. Moreover, several non-target fluorotelomers (12:2 FTOH, 14:2 FTOH and 10:2 FTI) were identified in raw effluent samples. These long-chain fluorotelomers have high bioaccumulative potential in the aquatic environment compared with short-chain fluorotelomers such as 6:2 FTOH and 6:2 FTI. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Introducing Students to Gas Chromatography-Mass Spectrometry Analysis and Determination of Kerosene Components in a Complex Mixture

    ERIC Educational Resources Information Center

    Pacot, Giselle Mae M.; Lee, Lyn May; Chin, Sung-Tong; Marriott, Philip J.

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) are useful in many separation and characterization procedures. GC-MS is now a common tool in industry and research, and increasingly, GC-MS/MS is applied to the measurement of trace components in complex mixtures. This report describes an upper-level undergraduate experiment…

  2. Ion and gas chromatography mass spectrometry investigations of organophosphates in lithium ion battery electrolytes by electrochemical aging at elevated cathode potentials

    NASA Astrophysics Data System (ADS)

    Weber, Waldemar; Wagner, Ralf; Streipert, Benjamin; Kraft, Vadim; Winter, Martin; Nowak, Sascha

    2016-02-01

    The electrochemical aging of commercial non-aqueous lithium hexafluorophosphate (LiPF6)/organic carbonate solvent based lithium ion battery electrolyte has been investigated in view of the formation of ionic and non-ionic alkylated phosphates. Subject was a solvent mixture of ethylene carbonate/ethyl methyl carbonate EC:EMC (1:1, by wt.) with 1 M LiPF6 (LP50 Selectilyte™, BASF). The analysis was carried out by ion chromatography coupled with electrospray ionization mass spectrometry (ESI-MS) for ionic compounds and (headspace) gas chromatography mass spectrometry ((HS)-GC-MS) for non-ionic compounds. The electrochemical aging was performed by galvanostatic charge/discharge cycling and potentiostatic experiments with LiNi0.5Mn1.5O4 (LMNO) as cathode material at increased cut-off potentials (>4.5 V vs. Li/Li+). A strong dependence of the formation of organophosphates on the applied electrode potential was observed and investigated by quantitative analysis of the formed phosphates. In addition, new possible ;fingerprint; compounds for describing the electrolyte status were investigated and compared to existing compounds.

  3. Development of a gas chromatography method for the determination of isotretinoin and its degradation products in pharmaceuticals.

    PubMed

    Lima, Eliana Martins; Diniz, Danielle G Almeida; Antoniosi-Filho, Nelson R

    2005-07-15

    This paper describes the development of a gas chromatography (GC) method used for the assay of isotretinoin in its isolated form and in pharmaceutical formulations. Isotretinoin soft and hard gelatin capsules were prepared with various excipients. The performance of the proposed gas chromatography method was compared to that of traditional high performance liquid chromatography (HPLC) systems for this substance, and the GC parameters were established based on several preliminary tests, including thermal analysis of isotretinoin. Results showed that gas chromatography-flame ionization detector (GC-FID) exhibited a separation efficiency superior to that of HPLC, particularly for separating isotretinoin degradation products. This method was proven to be effectively applicable to stability evaluation assays of isotretinoin and isotretinoin based pharmaceuticals.

  4. Why do Ladybugs Smell Bad? In-vivo Quantification of Odorous Insect Kairomones with SPME and Multidimensional GC-MS-Olfactometry

    NASA Astrophysics Data System (ADS)

    Cai, Lingshuang; Koziel, Jacek A.; O'Neal, Matthew E.

    2009-05-01

    Winemakers, small fruit growers, and homeowners are concerned with noxious compounds released by multicolored Asian ladybird beetles (Harmonia axyridis, Coleoptera: Coccinellidae). New method based on headspace solid phase microextraction (HS-SPME) coupled with multidimensional gas chromatography mass spectrometry—olfactometry (MDGC-MS-O) system was developed for extraction, isolation and simultaneous identification of compounds responsible for the characteristic odor of live H. axyridis. Four methoxypyrazines (MPs) were identified in headspace volatiles of live H. axyridis as those responsible for the characteristic odor: 2, 5-dimethy1-3-methoxypyrazine (DMMP), 2-isopropy1-3-methoxypyrazine (IPMP), 2-sec-buty1-3-methoxypyrazine (SBMP), and 2-isobuty1-3-methoxypyrazine (IBMP). To the best of our knowledge this is the first report of H. axyridis releasing DMMP and the first report of this compound being a component of the H. axyridis characteristic odor. Quantification of three MPs (IPMP, SBMP and IBMP) emitted from live H. axyridis were performed using external calibration with HS-SPME and direct injections. A linear relationship (R2>0.9958 for all 3 MPs) between MS response and concentration of standard was observed over a concentration range from 0.1 ng L-1 to 0.05 μg L-1 for HS-SPME-GC-MS. The method detection limits (MDL) based on multidimensional GC-MS approach for three MPs were estimated to be between 0.020 ng L-1. to 0.022 ng L-1. This methodology is applicable for in vivo determination of odor-causing chemicals associated with emissions of volatiles from insects.

  5. Evaporation Rates of Chemical Warfare Agents Using 5-CM Wind Tunnels I. CASARM Sulfur Mustard (HD) from Glass

    DTIC Science & Technology

    2008-10-01

    Blank CONTENTS 1. INTRODUCTION 9 2. EXPERIMENTAL PROCEDURES 9 2.1 Wind Tunnel 9 2.2 Agent 10 2.3 Gas Chromatography /Mass Spectrometry Detection 10...protective equipment. 2.3 Gas Chromatography /Mass Spectrometry Detection (GC/MSD) The GC/MSD analysis of the thermal desorption tubes was performed on a...coupled to thermal desorption tubes that were analyzed using gas chromatography /mass spectrometry detection (GC/MSD). Differences between the tunnels

  6. A Study on the Reliability of an On-Site Oral Fluid Drug Test in a Recreational Context

    PubMed Central

    Gentili, Stefano; Tittarelli, Roberta; Mannocchi, Giulio

    2016-01-01

    The reliability of DrugWipe 5A on site test for principal drugs of abuse (cannabis, amphetamines, cocaine, and opiates) detection in oral fluid was assessed by comparing the on-site results with headspace solid-phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS) analysis on samples extracted by the device collection pad. Oral fluid samples were collected at recreational settings (e.g., discos, pubs, and music bars) of Rome metropolitan area. Eighty-three club goers underwent the on-site drug screening test with one device. Independently from the result obtained, a second device was used just to collect another oral fluid sample subsequently extracted and analyzed in the laboratory following HS-SPME procedure, gas chromatographic separation by a capillary column, and MS detection by electron impact ionization. DrugWipe 5A on-site test showed 54 samples (65.1%) positive to one or more drugs of abuse, whereas 75 samples (90.4%) tested positive for one or more substances following GC-MS assay. Comparing the obtained results, the device showed sensitivity, specificity, and accuracy around 80% for amphetamines class. Sensitivity (67 and 50%) was obtained for cocaine and opiates, while both sensitivity and accuracy were unsuccessful (29 and 53%, resp.) for cannabis, underlying the limitation of the device for this latter drug class. PMID:27610266

  7. Identification of volatiles from pineapple (Ananas comosus L.) pulp by comprehensive two-dimensional gas chromatography and gas chromatography/mass spectrometry.

    PubMed

    Pedroso, Marcio P; Ferreira, Ernesto C; Hantao, Leandro W; Bogusz, Stanislau; Augusto, Fabio

    2011-07-01

    Combining qualitative data from the chromatographic structure of 2-D gas chromatography with flame ionization detection (GC×GC-FID) and that from gas chromatography-mass spectrometry (GC/MS) should result in a more accurate assignment of the peak identities than the simple analysis by GC/MS, where coelution of analytes is unavoidable in highly complex samples (rendering spectra unsuitable for qualitative purposes) or for compounds in very low concentrations. Using data from GC×GC-FID combined with GC/MS can reveal coelutions that were not detected by mass spectra deconvolution software. In addition, some compounds can be identified according to the structure of the GC×GC-FID chromatogram. In this article, the volatile fractions of fresh and dehydrated pineapple pulp were evaluated. The extraction of the volatiles was performed by dynamic headspace extraction coupled to solid-phase microextraction (DHS-SPME), a technique appropriate for slurries or solid matrices. Extracted analytes were then analyzed by GC×GC-FID and GC/MS. The results obtained using both techniques were combined to improve compound identifications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. DIRECT-DEPOSITION INFRARED SPECTROMETRY WITH GAS AND SUPERCRITICAL FLUID CHROMATOGRAPHY

    EPA Science Inventory

    A direct-deposition Fourier transform infrared (FT-IR) system has been evaluated for applicability to gas chromatography (GC) and supercritical fluid chromatography (SFC) of environmental analytes. A 100-um i.d. fused-silica transfer line was used for GC, and a 50-um transfer lin...

  9. Emission pattern of semi-volatile organic compounds from recycled styrenic polymers using headspace solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Vilaplana, Francisco; Martínez-Sanz, Marta; Ribes-Greus, Amparo; Karlsson, Sigbritt

    2010-01-15

    The emission of low molecular weight compounds from recycled high-impact polystyrene (HIPS) has been investigated using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS). Four released target analytes (styrene, benzaldehyde, acetophenone, and 2-phenylpropanal) were selected for the optimisation of the HS-SPME sampling procedure, by analysing operating parameters such as type of SPME fibre (polarity and operating mechanism), particle size, extraction temperature and time. 26 different compounds were identified to be released at different temperatures from recycled HIPS, including residues of polymerisation, oxidated derivates of styrene, and additives. The type of SPME fibre employed in the sampling procedure affected the detection of emitted components. An adsorptive fibre such as carbowax/polydimethylsiloxane (CAR/PDMS fibre) offered good selectivity for both non-polar and polar volatile compounds at lower temperatures; higher temperatures result in interferences from less-volatile released compounds. An absorptive fibre as polydimethylsiloxane (PDMS) fibre is suitable for the detection of less-volatile non-polar molecules at higher temperatures. The nature and relative amount of the emitted compounds increased with higher exposure temperature and smaller polymeric particle size. HS-SPME proves to be a suitable technique for screening the emission of semi-volatile organic compounds (SVOCs) from polymeric materials; reliable quantification of the content of target analytes in recycled HIPS is however difficult due to the complex mass-transfer processes involved, matrix effects, and the difficulties in equilibrating the analytical system. 2009 Elsevier B.V. All rights reserved.

  10. Metabolite profiling on apple volatile content based on solid phase microextraction and gas-chromatography time of flight mass spectrometry.

    PubMed

    Aprea, Eugenio; Gika, Helen; Carlin, Silvia; Theodoridis, Georgios; Vrhovsek, Urska; Mattivi, Fulvio

    2011-07-15

    A headspace SPME GC-TOF-MS method was developed for the acquisition of metabolite profiles of apple volatiles. As a first step, an experimental design was applied to find out the most appropriate conditions for the extraction of apple volatile compounds by SPME. The selected SPME method was applied in profiling of four different apple varieties by GC-EI-TOF-MS. Full scan GC-MS data were processed by MarkerLynx software for peak picking, normalisation, alignment and feature extraction. Advanced chemometric/statistical techniques (PCA and PLS-DA) were used to explore data and extract useful information. Characteristic markers of each variety were successively identified using the NIST library thus providing useful information for variety classification. The developed HS-SPME sampling method is fully automated and proved useful in obtaining the fingerprint of the volatile content of the fruit. The described analytical protocol can aid in further studies of the apple metabolome. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Quantitative analysis of 2-furfural and 5-methylfurfural in different Italian vinegars by headspace solid-phase microextraction coupled to gas chromatography-mass spectrometry using isotope dilution.

    PubMed

    Giordano, Lucia; Calabrese, Roberto; Davoli, Enrico; Rotilio, Domenico

    2003-10-31

    A new method was developed for the determination of 2-furfural (2-F) and 5-methylfurfural (5-MF), two products of Maillard reaction in vinegar, with head-space solid-phase microextraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). A divinylbenzene (DVB)/carboxen (CAR)/polydimethylsiloxane (PDMS) fibre was used and SPME conditions were optimised, studying ionic strength effect, temperature effect and adsorption time. Both analytes were determined by calibration established on 2-furfural-d4 (2-F-d4). The method showed good linearity in the range studied (from 16 to 0.12 mg/l), with a regression coefficient r2 of 0.9999. Inter-batch precision and accuracy were found between 14.9 and 6.0% and between -11.7 and 0.2%, respectively. Detection limit was 15 microg/l. The method is simple and accurate and it has been applied to a series of balsamic and non-balsamic vinegars.

  12. A new method for the determination of short-chain fatty acids from the aliphatic series in wines by headspace solid-phase microextraction-gas chromatography-ion trap mass spectrometry.

    PubMed

    Olivero, Sergio J Pérez; Trujillo, Juan P Pérez

    2011-06-24

    A new analytical method for the determination of nine short-chain fatty acids (acetic, propionic, isobutyric, butyric, isovaleric, 2-methylbutyric, hexanoic, octanoic and decanoic acids) in wines using the automated HS/SPME-GC-ITMS technique was developed and optimised. Five different SPME fibers were tested and the influence of different factors such as temperature and time of extraction, temperature and time of desorption, pH, strength ionic, tannins, anthocyans, SO(2), sugar and ethanol content were studied and optimised using model solutions. Some analytes showed matrix effect so a study of recoveries was performed. The proposed HS/SPME-GC-ITMS method, that covers the concentration range of the different analytes in wines, showed wide linear ranges, values of repeatability and reproducibility lower than 4.0% of RSD and detection limits between 3 and 257 μgL(-1), lower than the olfactory thresholds. The optimised method is a suitable technique for the quantitative analysis of short-chain fatty acids from the aliphatic series in real samples of white, rose and red wines. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. HS-SPME-GC-MS/MS Method for the Rapid and Sensitive Quantitation of 2-Acetyl-1-pyrroline in Single Rice Kernels.

    PubMed

    Hopfer, Helene; Jodari, Farman; Negre-Zakharov, Florence; Wylie, Phillip L; Ebeler, Susan E

    2016-05-25

    Demand for aromatic rice varieties (e.g., Basmati) is increasing in the US. Aromatic varieties typically have elevated levels of the aroma compound 2-acetyl-1-pyrroline (2AP). Due to its very low aroma threshold, analysis of 2AP provides a useful screening tool for rice breeders. Methods for 2AP analysis in rice should quantitate 2AP at or below sensory threshold level, avoid artifactual 2AP generation, and be able to analyze single rice kernels in cases where only small sample quantities are available (e.g., breeding trials). We combined headspace solid phase microextraction with gas chromatography tandem mass spectrometry (HS-SPME-GC-MS/MS) for analysis of 2AP, using an extraction temperature of 40 °C and a stable isotopologue as internal standard. 2AP calibrations were linear between the concentrations of 53 and 5380 pg/g, with detection limits below the sensory threshold of 2AP. Forty-eight aromatic and nonaromatic, milled rice samples from three harvest years were screened with the method for their 2AP content, and overall reproducibility, observed for all samples, ranged from 5% for experimental aromatic lines to 33% for nonaromatic lines.

  14. Measurement of natural carbon isotopic composition of acetone in human urine.

    PubMed

    Yamada, Keita; Ohishi, Kazuki; Gilbert, Alexis; Akasaka, Mai; Yoshida, Naohiro; Yoshimura, Ryoko

    2016-02-01

    The natural carbon isotopic composition of acetone in urine was measured in healthy subjects using gas chromatography-combustion-isotope ratio mass spectrometry combined with headspace solid-phase microextraction (HS-SPME-GC-C-IRMS). Before applying the technique to a urine sample, we optimized the measurement conditions of HS-SPME-GC-C-IRMS using aqueous solutions of commercial acetone reagents. The optimization enabled us to determine the carbon isotopic compositions within ±0.2 ‰ of precision and ±0.3‰ of error using 0.05 or 0.2 mL of aqueous solutions with acetone concentrations of 0.3-121 mg/L. For several days, we monitored the carbon isotopic compositions and concentrations of acetone in urine from three subjects who lived a daily life with no restrictions. We also monitored one subject for 3 days including a fasting period of 24 h. These results suggest that changes in the availability of glucose in the liver are reflected in changes in the carbon isotopic compositions of urine acetone. Results demonstrate that carbon isotopic measurement of metabolites in human biological samples at natural abundance levels has great potential as a tool for detecting metabolic changes caused by changes in physiological states and disease.

  15. Sensitive Determination of Volatile Organic Compounds and Aldehydes in Tattoo Inks.

    PubMed

    Lim, Hyun-Hee; Shin, Ho-Sang

    2017-02-01

    As the popularity of body art including tattoo ink has increased, the safety associated with it has become an important interest. In this study, twenty volatile organic compounds (VOCs) and two aldehydes in tattoo inks were identified and quantified. Headspace and gas chromatography-mass spectrometry (HS GC-MS) for the VOCs and HS GC-MS based on derivatization with 2,2,2-trifluoroethylhydrazine (TFEH) for aldehydes was developed. Benzene, chloroform, toluene, ethylbenzene, m-xylene, p-xylene, o-xylene, propylbenzene, chlorobenzene, tert-butylbenzene, 1,3,5-trimethylbenzene, styrene, 1,2,4-trimethylbenzene, 2-chlorotoluene, 4-chlorotoluene, 1,3-dichlorobenzene, 1,4-dichlorobenzene, 1,2-dichlorobenzene, 1,2,4-trichlorobenzene and isopropyl alcohol were detected with the concentration range of 0.02-207,000 mg/kg in 16 different tattoo inks. Formaldehyde and acetaldehyde were detected with the concentration range of 0.4-308 mg/kg in the same samples. Our analytical results represent solvents used intentionally or non-intentionally in tattoo inks, and thus they may provide important information for national regulation. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Aroma characterization of chinese rice wine by gas chromatography-olfactometry, chemical quantitative analysis, and aroma reconstitution.

    PubMed

    Chen, Shuang; Xu, Yan; Qian, Michael C

    2013-11-27

    The aroma profile of Chinese rice wine was investigated in this study. The volatile compounds in a traditional Chinese rice wine were extracted using Lichrolut EN and further separated by silica gel normal phase chromatography. Seventy-three aroma-active compounds were identified by gas chromatography-olfactometry (GC-O) and gas chromatography-mass spectrometry (GC-MS). In addition to acids, esters, and alcohols, benzaldehyde, vanillin, geosmin, and γ-nonalactone were identified to be potentially important to Chinse rice wine. The concentration of these aroma-active compounds in the Chinese rice wine was further quantitated by combination of four different methods, including headsapce-gas chromatography, solid phase microextraction-gas chromatography (SPME)-GC-MS, solid-phase extraction-GC-MS, and SPME-GC-pulsed flame photometric detection (PFPD). Quantitative results showed that 34 aroma compounds were at concentrations higher than their corresponding odor thresholds. On the basis of the odor activity values (OAVs), vanillin, dimethyl trisulfide, β-phenylethyl alcohol, guaiacol, geosmin, and benzaldehyde could be responsible for the unique aroma of Chinese rice wine. An aroma reconstitution model prepared by mixing 34 aroma compounds with OAVs > 1 in an odorless Chinese rice wine matrix showed a good similarity to the aroma of the original Chinese rice wine.

  17. Improved Thermal Modulator for Gas Chromatography

    NASA Technical Reports Server (NTRS)

    Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.

    2008-01-01

    An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

  18. Aroma volatiles obtained at harvest by HS-SPME/GC-MS and INDEX/MS-E-nose fingerprint discriminate climacteric behaviour in melon fruit.

    PubMed

    Chaparro-Torres, Libia A; Bueso, María C; Fernández-Trujillo, Juan P

    2016-05-01

    Melon aroma volatiles were extracted at harvest from juice of a climacteric near-isogenic line (NIL) SC3-5-1 with two quantitative trait loci (QTLs) introgressed which produced climacteric behaviour and its non-climacteric parental (PS) using two methodologies of analysis: static headspace solid phase micro-extraction (HS-SPME) by gas chromatography-mass spectrometry (GC-MS) and inside needle dynamic extraction (INDEX) by MS-based electronic nose (MS-E-nose). Of the 137 volatiles compounds identified, most were found at significantly higher concentrations in SC3-5-1 than in PS in both seasons. These volatiles were mostly esters, alcohols, sulfur-derived esters and even some aldehydes and others. The number of variables with high correlation values was reduced by using correlation network analysis. Partial least squares-discriminant analysis (PLS-DA) achieved the correct classification of PS and SC3-5-1. The ions m/z 74, 91, 104, 105, 106 and 108, mainly volatile derivatives precursor phenylalanine, were the most discriminant in SC3-5-1 and PS. As many as 104 QTLs were mapped in season 1 and at least 78 QTLs in each season with an effect above the PS mean. GC-MS gave better discrimination than E-nose. Most of the QTLs that mapped in both seasons enhanced aroma volatiles associated with climacteric behaviour. © 2015 Society of Chemical Industry.

  19. Artemisia umbelliformis Lam. and Génépi Liqueur: Volatile Profile as Diagnostic Marker for Geographic Origin and To Predict Liqueur Safety.

    PubMed

    Boggia, Lorenzo; Pignata, Giuseppe; Sgorbini, Barbara; Colombo, Maria Laura; Marengo, Arianna; Casale, Manuela; Nicola, Silvana; Bicchi, Carlo; Rubiolo, Patrizia

    2017-04-05

    Artemisia umbelliformis, commonly known as "white génépi", is characterized by a volatile fraction rich in α- and β-thujones, two monoterpenoids; under European Union (EU) regulations these are limited to 35 mg/L in Artemisia-based beverages because of their recognized activity on the human central nervous system. This study reports the results of an investigation to define the geographical origin and thujone content of individual plants of A. umbelliformis from different geographical sites, cultivated experimentally at a single site, and to predict the thujone content in the resulting liqueurs through their volatile fraction. Headspace solid phase microextraction (HS-SPME) combined with gas chromatography-mass spectrometry (GC-MS) and non-separative HS-SPME-MS were used as analytical platforms to create a database suitable for chemometric description and prediction through linear discriminant analysis (LDA). HS-SPME-MS was applied to shorten analysis time. With both approaches, a diagnostic prediction of (i) plant geographical origin and (ii) thujone content of plant-related liqueurs could be made.

  20. Simultaneous determination of 76 micropollutants in water samples by headspace solid phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Martínez, C; Ramírez, N; Gómez, V; Pocurull, E; Borrull, F

    2013-11-15

    This study focuses on the development of an analytical method based on headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 76 micropollutants in water samples. The selected micropollutants include volatile organic compounds (VOCs) (e.g. chlorobenzenes, chloroalkanes), endocrine disrupting compounds (EDCs) (e.g. bisphenol A and tributyl phosphate), odour compounds (e.g. limonene, phenol), fragrance allergens (e.g. geraniol, eugenol) and some pesticides (e.g. heptachlor, terbutryn). The experimental conditions affecting their extraction, such as the type of fibre, temperature and time of extraction, sample volume and ionic strength of the samples were optimized using HS-SPME. The method showed good linear range, reproducibility between days, repeatability and low detection limits (at ng L(-1) levels). The validated method has been applied to determine the target organic micropollutants in aqueous samples from different experimental research units of surface water, sea water, waste water and those effluents of advance membrane treatments. The optimized method showed good performance in the different types of samples studied. The analysis revealed the presence of several micropollutants at concentrations between 20 and 5000 μg L(-1), such as ethylbenzene, o-xylene, p-isopropilbenzene, D-limonene, citral and isoeugenol, due to the fact that these species are commonly used in domestic and industrial applications. © 2013 Elsevier B.V. All rights reserved.

  1. Solid phase microextraction applied to the analysis of organophosphorus insecticides in fruits.

    PubMed

    Fytianos, K; Raikos, N; Theodoridis, G; Velinova, Z; Tsoukali, H

    2006-12-01

    Trace amounts of organophosphorus pesticides (OPs) were determined in various fruits by headspace solid phase microextraction (HS-SPME) and gas chromatography-nitrogen phosphorous detection (GC-NPD). Sampling from the headspace enhanced method selectivity, whereas at the same time improved fiber life time and method sensitivity. Diazinon, parathion, methyl parathion, malathion and fenithrothion were determined in various fruits: more than 150 samples of 21 types of fruits were studied. SPME-GC-NPD provided a useful and very efficient analytical tool: method linearity ranged from 1.2 to 700 ng/ml. Limits of detection (LODs) and quantitation (LOQs) ranged from 0.03 to 3 ng/ml and 0.12 to 10 ng/ml respectively, values well below the residue limits set by the EU. Less than 2% of the samples were found positive containing amounts higher than the EU limits. The effect of fruit peeling and washing was also investigated.

  2. Determination of anabolic steroids with gas chromatography-ion trap mass spectrometry using hydrogen as carrier gas.

    PubMed

    Impens, S; De Wasch, K; De Brabander, H

    2001-01-01

    Helium is considered to be the ideal carrier gas for gas chromatography/mass spectrometry (GC/MS) in general, and for use with an ion trap in particular. Helium is an inert gas, can be used without special precautions for security and, moreover, it is needed as a damping gas in the trap. A disadvantage of helium is the high viscosity resulting in long GC run times. In this work hydrogen was tested as an alternative carrier gas for GC in performing GC/MS analyses. A hydrogen generator was used as a safe source of hydrogen gas. It is demonstrated that hydrogen can be used as a carrier gas for the gas chromatograph in combination with helium as make-up gas for the trap. The analysis time was thus shortened and the chromatographic performance was optimized. Although hydrogen has proven useful as a carrier gas in gas chromatography coupled to standard detectors such as ECD or FID, its use is not mentioned extensively in the literature concerning gas chromatography-ion trap mass spectrometry. However, it is worth considering as a possibility because of its chromatographic advantages and its advantageous price when using a hydrogen generator. Copyright 2001 John Wiley & Sons, Ltd.

  3. Analysis of fragrance compounds in blood samples of mice by gas chromatography, mass spectrometry, GC/FTIR and GC/AES after inhalation of sandalwood oil.

    PubMed

    Jirovetz, L; Buchbauer, G; Jäger, W; Woidich, A; Nikiforov, A

    1992-01-01

    After inhalation experiments with sandalwood oil and the pure fragrance compounds coumarin and alpha-terpineol, substances were detected and measured in the blood samples of test animals (mice) using gas chromatography/mass spectrometry (GC/MS) (MID) in connection with GC/FTIR (SWC), GC/AES (carbon and oxygen trace) and flame ionization detection/gas chromatography. Using tiglinic acid benzyl ester as the internal standard the following concentrations in serum could be found: alpha-santalol 6.1 ng/mL, beta-santalol 5.3 ng/mL and alpha-santalene 0.5 ng/mL. In separate inhalation experiments with coumarin and with alpha-terpineol the corresponding concentrations were 7.7 ng/mL and 6.9 ng/mL, respectively.

  4. Why do Ladybugs Smell Bad? In-vivo Quantification of Odorous Insect Kairomones with SPME and Multidimensional GC-MS-Olfactometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai Lingshuang; Koziel, Jacek A.; O'Neal, Matthew E.

    2009-05-23

    Winemakers, small fruit growers, and homeowners are concerned with noxious compounds released by multicolored Asian ladybird beetles (Harmonia axyridis, Coleoptera: Coccinellidae). New method based on headspace solid phase microextraction (HS-SPME) coupled with multidimensional gas chromatography mass spectrometry--olfactometry (MDGC-MS-O) system was developed for extraction, isolation and simultaneous identification of compounds responsible for the characteristic odor of live H. axyridis. Four methoxypyrazines (MPs) were identified in headspace volatiles of live H. axyridis as those responsible for the characteristic odor: 2, 5-dimethy1-3-methoxypyrazine (DMMP), 2-isopropy1-3-methoxypyrazine (IPMP), 2-sec-buty1-3-methoxypyrazine (SBMP), and 2-isobuty1-3-methoxypyrazine (IBMP). To the best of our knowledge this is the first report of H.more » axyridis releasing DMMP and the first report of this compound being a component of the H. axyridis characteristic odor. Quantification of three MPs (IPMP, SBMP and IBMP) emitted from live H. axyridis were performed using external calibration with HS-SPME and direct injections. A linear relationship (R{sup 2}>0.9958 for all 3 MPs) between MS response and concentration of standard was observed over a concentration range from 0.1 ng L{sup -1} to 0.05 {mu}g L{sup -1} for HS-SPME-GC-MS. The method detection limits (MDL) based on multidimensional GC-MS approach for three MPs were estimated to be between 0.020 ng L{sup -1}. to 0.022 ng L{sup -1}. This methodology is applicable for in vivo determination of odor-causing chemicals associated with emissions of volatiles from insects.« less

  5. Identification of terpenes and essential oils by means of static headspace gas chromatography-ion mobility spectrometry.

    PubMed

    Rodríguez-Maecker, Roman; Vyhmeister, Eduardo; Meisen, Stefan; Rosales Martinez, Antonio; Kuklya, Andriy; Telgheder, Ursula

    2017-11-01

    Static headspace gas chromatography-ion mobility spectrometry (SHS GC-IMS) is a relatively new analytical technique that has considerable potential for analysis of volatile organic compounds (VOCs). In this study, SHS GC-IMS was used for the identification of the major terpene components of various essential oils (EOs). Based on the data obtained from 25 terpene standards and 50 EOs, a database for fingerprint identification of characteristic terpenes and EOs was generated utilizing SHS GC-IMS for authenticity testing of fragrances in foods, cosmetics, and personal care products. This database contains specific normalized IMS drift times and GC retention indices for 50 terpene components of EOs. Initially, the SHS GC-IMS parameters, e.g., drift gas and carrier gas flow rates, drift tube, and column temperatures, were evaluated to determine suitable operating conditions for terpene separation and identification. Gas chromatography-mass spectrometry (GC-MS) was used as a reference method for the identification of terpenes in EOs. The fingerprint pattern based on the normalized IMS drift times and retention indices of 50 terpenes is presented for 50 EOs. The applicability of the method was proven on examples of ten commercially available food, cosmetic, and personal care product samples. The results confirm the suitability of SHS GC-IMS as a powerful analytical technique for direct identification of terpene components in solid and liquid samples without any pretreatment. Graphical abstract Fingerprint pattern identification of terpenes and essential oils using static headspace gas chromatography-ion mobility spectrometry.

  6. Axial thermal gradients in microchip gas chromatography.

    PubMed

    Wang, Anzi; Hynynen, Sampo; Hawkins, Aaron R; Tolley, Samuel E; Tolley, H Dennis; Lee, Milton L

    2014-12-29

    Fabrication technologies for microelectromechanical systems (MEMS) allow miniaturization of conventional benchtop gas chromatography (GC) to portable, palm-sized microfabricated GC (μGC) devices, which are suitable for on-site chemical analysis and remote sensing. The separation performance of μGC systems, however, has not been on par with conventional GC. Column efficiency, peak symmetry and resolution are often compromised by column defects and non-ideal injections. The relatively low performance of μGC devices has impeded their further commercialization and broader application. In this work, the separation performance of μGC columns was improved by incorporating thermal gradient gas chromatography (TGGC). The analysis time was ∼20% shorter for TGGC separations compared to conventional temperature-programmed GC (TPGC) when a wide sample band was introduced into the column. Up to 50% reduction in peak tailing was observed for polar analytes, which improved their resolution. The signal-to-noise ratios (S/N) of late-eluting peaks were increased by 3-4 fold. The unique focusing effect of TGGC overcomes many of the previous shortcomings inherent in μGC analyses. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. 75 FR 38156 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-01

    ... Systems (CS-MS), High Performance Liquid Chromatography (HPLC) Systems, Gas Chromatography Mass... Chromatography (HPLC) Systems, Gas Chromatography Mass Spectrometry (GC-MS) Systems, and, Inductively Coupled...

  8. Performance evaluation of a versatile multidimensional chromatographic preparative system based on three-dimensional gas chromatography and liquid chromatography-two-dimensional gas chromatography for the collection of volatile constituents.

    PubMed

    Pantò, Sebastiano; Sciarrone, Danilo; Maimone, Mariarosa; Ragonese, Carla; Giofrè, Salvatore; Donato, Paola; Farnetti, Sara; Mondello, Luigi

    2015-10-23

    The present research deals with the multi-collection of the most important sesquiterpene alcohols belonging to sandalwood essential oil, as reported by the international regulations: (Z)-α-santalol, (Z)-α-trans bergamotol, (Z)-β-santalol, epi-(Z)-β-santalol, α-bisabolol, (Z)-lanceol, and (Z)-nuciferol. A versatile multidimensional preparative system, based on the hyphenation of liquid and gas chromatography techniques, was operated in the LC-GC-GC-prep or GC-GC-GC-prep configuration, depending on the concentration to be collected from the sample, without any hardware or software modification. The system was equipped with a silica LC column in combination with polyethylene glycol-poly(5% diphenyl/95% dimethylsiloxane)-medium polarity ionic liquid or β-cyclodextrin based GC stationary phases. The GC-GC-GC-prep configuration was exploited for the collection of four components, by using a conventional split/splitless injector, while the LC-GC-GC-prep approach was applied for three low abundant components (<5%), in order to increase the quantity collected within a single run, by the LC injection of a high sample amount. All target compounds, whose determination is hampered by the unavailability of commercial standards, were collected at milligram levels and with a high degree of purity (>87%). Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Simultaneous determination of 14 disinfection by-products in meat products using microwave-assisted extraction and static headspace coupled to gas chromatography-mass spectrometry.

    PubMed

    Cardador, Maria Jose; Gallego, Mercedes

    2017-08-04

    This paper described the first analytical method to simultaneously determine 14 disinfection by-products (DBPs) in meat products using microwave-assisted extraction (MAE) and static headspace (SHS) followed by gas chromatography-mass spectrometry (GC-MS). The DBPs included were 4 trihalomethanes, 7 haloacetic acids, 2 haloacetonitriles and trichloronitromethane, which are commonly formed as a consequence of the disinfection process of water. The combination of the MAE and SHS techniques allows meat samples to be analysed in two sequential steps into the same HS vial in spite of the sample's complexity. Detection limits were obtained within the range of 0.06-0.70ng/g, and the average relative standard deviation was 7.4%. Recoveries throughout the whole process were between 86 and 95%. The SHS-GC-MS method was applied to determine DBPs in meat products with different industrial processing which could be contaminated through contact with disinfectants and/or treated water employed in the factory either for washing or for the cooking of meat. Up to 5 DBPs were found at ng/g levels in about 36% of the samples analysed, cooked ham being the most contaminated meat product because of the brine solutions employed in its manufacturing process. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Optimization of the HS-SPME-GC-IT/MS method using a central composite design for volatile carbonyl compounds determination in beers.

    PubMed

    Moreira, Nathalie; Meireles, Sónia; Brandão, Tiago; de Pinho, Paula Guedes

    2013-12-15

    An automated headspace solid-phase microextraction (HS-SPME) combined with gas chromatography and ion trap mass spectrometry detection (GC-IT/MS) was developed in order to quantify a large number of carbonyl compounds in beers. Carbonyl compounds were previously derivatized with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA). Volatile carbonyl compounds associated with staling beer aroma includes alkanals, alkenals, alkadienals, dicarbonyl compounds, Strecker aldehydes, ketones and furans. The HS-SPME was performed using a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber. The procedures were optimized for HS-SPME pre-incubation temperature and time, extraction temperature and time, and PFBHA addition. A central composite design was used in the optimization of extraction conditions and PFBHA addition. The volatile compounds showed optimal extraction incubating 5 ml of beer with 700 mg l(-1) of PFBHA for 7 min and extracted for more 20 min at 45 °C. The method was validated with regard to the linearity, repeatability, inter and intra-day precision and accuracy. The method achieved detection limits ranging from 0.003 to 0.510 µg l(-1), except for furans (1.54-3.44 µg l(-1)). The quantification limits varied from 0.010 to 1.55 µg l(-1), except for 2-furfural (4.68 µg l(-1)), 5-methyl-2-furfural (5.82 µg l(-1)) and 5-hyfroxymethylfurfural (10.4 µg l(-1)). Repeatability values of all compounds were lower than 17%. The method accuracy was satisfactory with recoveries ranging from 88% to 114%. The validated method showed to be suitable for a fast and reliable determination of main carbonyl compounds in beers. © 2013 Published by Elsevier B.V.

  11. Exudate Chemical Profiles Derived from Lespedeza and Other Tallgrass Prairie Plant Species

    DTIC Science & Technology

    2017-05-01

    assayed by liquid chromatography–tandem mass spec- trometry (LC-MS/MS) and gas chromatography/mass spectrometry (GC/MS). The objective was to elucidate...molecular weight compounds were identified via gas chromatography/mass spectrometry (GC/MS) and tentatively identified as benzophenone and 1,4...diacetylbenzene. Three higher molecular weight compounds were identified by liquid chromatography-electrospray ionization- mass spectrometry (LC-ESI-MS

  12. Optimization, validation and application of headspace solid-phase microextraction gas chromatography for the determination of 1-nitro-2-phenylethane and methyleugenol from Aniba canelilla (H.B.K.) Mez essential oil in skin permeation samples.

    PubMed

    Kreutz, Tainá; Lucca, Letícia G; Loureiro-Paes, Orlando A R; Teixeira, Helder F; Veiga, Valdir F; Limberger, Renata P; Ortega, George G; Koester, Letícia S

    2018-06-02

    Aniba canelilla (H.B.K.) Mez is an aromatic plant from the Amazon region whose essential oil has 1-nitro-2-phenylethane (NP) and methyleugenol (ME) as major compounds. Despite of the scientifically proven antifungal and anti-inflammatory activities for these compounds, there is no report up to date about the topical permeation or quantification of NP and ME on skin samples. The aim of this study was the validation of an optimized bioanalytical method by solid-phase microextraction in headspace mode in gas chromatograph with flame ionization detector (HS-SPME-GC-FID) for the determination of NP and ME from the oil in different samples from permeation study, such as porcine ear skin (PES) layers (stratum corneum, epidermis and dermis) and receptor fluid (RF). For this propose polydimethylsiloxane fibers (100 μm) were used and HS-SPME extraction condition consisted of 53 °C, 21 min, and 5% w.v -1 NaCl addition. The wide range of the calibration curve (2.08-207.87 μg mL -1 for NP and 0.40-40.41 μg mL -1 for ME), the presence of matrix interferences and the intrinsic characteristics of HS-SPME required a data linearization using Log 10 . Thereby, data and the gained results presented homoscedasticity, normalization of residues and adequate linearity (r 2  > 0.99) and accuracy for both compounds. In order to verify the applicability of the validated method, the HS-SPME-GC-FID procedure was performed to determine the amount of NP and ME permeated and retained in samples after Franz diffusion cell study from different dosages (20, 100 and 200 μL) of A. canelilla oil. Compounds permeation showed a progressive increase and penetration dependence based on the dosage applied. Furthermore, retention was in order receptor fluid > dermis > epidermis > stratum corneum for both compounds, suggesting NP and ME could penetrate deep tissue, probably due to the partition coefficient, mass, size, and solubility of these compounds. In conclusion, the proposed method by HS-SPME-GC-FID to quantify 1-nitro-2-phenylethane and methyleugenol from Aniba canelilla essential oil was able to determine selectively, precisely and accurately these main compounds in skin permeation samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Evaluation of ionic liquid stationary phases for one dimensional gas chromatography-mass spectrometry and comprehensive two dimensional gas chromatographic analyses of fatty acids in marine biota.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Vanormelingen, Pieter; Vyverman, Wim; Rumpel, Klaus; Xu, Guowang; Sandra, Pat

    2011-05-20

    Ionic liquid stationary phases were tested for one dimensional gas chromatography-mass spectrometry (GC-MS) and comprehensive two dimensional gas chromatography (GC×GC) of fatty acid methyl esters from algae. In comparison with polyethylene glycol and cyanopropyl substituted polar stationary phases, ionic liquid stationary phases SLB-IL 82 and SLB-IL 100 showed comparable resolution, but lower column bleeding with MS detection, resulting in better sensitivity. The selectivity and polarity of the ionic liquid phases are similar to a highly polar biscyanopropyl-silicone phase (e.g. HP-88). In GC×GC, using an apolar polydimethyl siloxane×polar ionic liquid column combination, an excellent group-type separation of fatty acids with different carbon numbers and number of unsaturations was obtained, providing information that is complementary to GC-MS identification. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. IDENTIFICATION OF DRINKING WATER CONTAMINANTS IN THE COURSE OF A CHILDHOOD CANCER INVESTIGATION IN TOMS RIVER, NEW JERSEY

    EPA Science Inventory

    Using a combination of gas chromatography/mass spectrometry (GC/MS) and gas chromatography/infrared spectroscopy (GC/IR) spectroscopic techniques, chemical contaminants and their hydrolysis products were identified in well water sampled in connection with a suspected childhood ca...

  15. Quantitation of monomers in poly(glyerol-co-diacid) gels using gas chromatography

    USDA-ARS?s Scientific Manuscript database

    The validation of a gas chromatography (GC) method developed to quantify amounts of starting material from the synthesis of hyperbranched polymers made from glycerol and either succinic acid, glutaric acid, or azelaic acid is described. The GC response to concentration was linear for all starting r...

  16. Evaluation of a headspace solid-phase microextraction method for the analysis of ignitable liquids in fire debris.

    PubMed

    Fettig, Ina; Krüger, Simone; Deubel, Jan H; Werrel, Martin; Raspe, Tina; Piechotta, Christian

    2014-05-01

    The chemical analysis of fire debris represents a crucial part in fire investigations to determine the cause of a fire. A headspace solid-phase microextraction (HS-SPME) procedure for the detection of ignitable liquids in fire debris using a fiber coated with a mixture of three different sorbent materials (Divinylbenzene/Carboxen/Polydimethylsiloxane, DVB/CAR/PDMS) is described. Gasoline and diesel fuel were spiked upon a preburnt matrix (wood charcoal), extracted and concentrated with HS-SPME and then analyzed with gas chromatography/mass spectrometry (GC/MS). The experimental conditions--extraction temperature, incubation and exposure time--were optimized. To assess the applicability of the method, fire debris samples were prepared in the smoke density chamber (SDC) and a controlled-atmosphere cone calorimeter. The developed methods were successfully applied to burnt particleboard and carpet samples. The results demonstrate that the procedure that has been developed here is suitable for detecting these ignitable liquids in highly burnt debris. © 2013 American Academy of Forensic Sciences.

  17. Lichenysin, a cyclooctapeptide occurring in Chinese liquor jiannanchun reduced the headspace concentration of phenolic off-flavors via hydrogen-bond interactions.

    PubMed

    Zhang, Rong; Wu, Qun; Xu, Yan

    2014-08-20

    Nonvolatile compounds play important roles in the quality of alcoholic beverages. In our previous work, a type of cyclooctapeptide lichenysin was newly identified in Chinese strong-aroma type liquor. In this work, it was found that lichenysin could selectively affect aroma volatility in strong-aroma type (Jiannanchun) liquor. Interaction of lichenysin and volatile phenolic compounds (off-odors in strong-aroma type liquor) was characterized using headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry (HS-SPME-GC-MS). HS-SPME results indicated that lichenysin very efficiently suppressed the volatility of phenolic compounds by 36-48% (P < 0.05). Thermodynamic analysis showed that the binding process was mainly mediated by hydrogen bonding. Furthermore, the mixture of lichenysin and 4-ethylguaiacol revealed intermolecular cross peaks between the aH (Val) of lichenysin and the 1H of 4-ethylguaiacol, by using nuclear Overhauser effect spectroscopy. This study will help to further understand the interaction mechanisms between flavor and nonvolatile matrix components in Chinese liquors.

  18. Speciation analysis of organotin compounds in human urine by headspace solid-phase micro-extraction and gas chromatography with pulsed flame photometric detection.

    PubMed

    Valenzuela, Aníbal; Lespes, Gaëtane; Quiroz, Waldo; Aguilar, Luis F; Bravo, Manuel A

    2014-07-01

    A new headspace solid-phase micro-extraction (HS-SPME) method followed by gas chromatography with pulsed flame photometric detection (GC-PFPD) analysis has been developed for the simultaneous determination of 11 organotin compounds, including methyl-, butyl-, phenyl- and octyltin derivates, in human urine. The methodology has been validated by the analysis of urine samples fortified with all analytes at different concentration levels, and recovery rates above 87% and relative precisions between 2% and 7% were obtained. Additionally, an experimental-design approach has been used to model the storage stability of organotin compounds in human urine, demonstrating that organotins are highly degraded in this medium, although their stability is satisfactory during the first 4 days of storage at 4 °C and pH=4. Finally, this methodology was applied to urine samples collected from harbor workers exposed to antifouling paints; methyl- and butyltins were detected, confirming human exposure in this type of work environment. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. [Determination of flavor compounds in foxtail millet wine by gas chromatography-mass spectrometry coupled with headspace solid phase microextraction].

    PubMed

    Liu, Jingke; Zhang, Aixia; Li, Shaohui; Zhao, Wei; Zhang, Yuzong; Xing, Guosheng

    2017-11-08

    To comprehensively understand flavor compounds and aroma characteristics of foxtail millet wine, extraction conditions were optimized with 85 μm polyacrylate (PA), 100 μm polydimethylsiloxane (PDMS), 75 μm carboxen (CAR)/PDMS and 50/30 μm divinylbenzene (DVB)/CAR/PDMS fibers. The flavor compounds in foxtail millet wine were investigated by gas chromatography-mass spectrometry (GC-MS) coupled with headspace solid phase microextraction (HS-SPME), and the odor characteristics and intensity were analyzed by odor active values (OAVs). The samples of 8 mL were placed in headspace vials with 1.5 g NaCl, then the headspace vials were heated at 60℃ for 40 min. Using HS-SPME with different fibers, a total of 55 flavor compounds were identified from the samples, including alcohols, esters, benzene derivatives, hydrocarbons, acids, aldehydes, ketones, terpenes, phenols and heterocycle compounds. The main flavor compounds were alcohols compounds. According to their OAVs, phenylethyl alcohol, styrene, 1-methyl-naphthalene, 2-methyl-naphthalene, benzaldehyde, benzeneacetaldehyde and 2-methoxy-phenol were established to be odor-active compounds. Phenylethyl alcohol and benzeneacetaldehyde were the most prominent odor-active compounds. PA and PDMS fibers had good extraction effect for polar and nonpolar compounds, respectively. CAR/PDMS and DVB/CAR/PDMS provided a similar compounds profile for moderate polar compounds. This research comprehensively determined flavor compounds of foxtail millet wine, and provided theoretical basis for product development and quality control.

  20. Optimization of headspace solid phase microextraction based on nano-structured ZnO combined with gas chromatography-mass spectrometry for preconcentration and determination of ultra-traces of chlorobenzenes in environmental samples.

    PubMed

    Ghasemi, Ensieh; Sillanpää, Mika

    2014-12-01

    In this study, a simple, novel and efficient preconcentration method for the determination of some chlorobenzenes (monochlorobenzene (MCB), three isomeric forms of dichlorobenzene (diCB), 1,3,5-trichlorobenzene (triCB) and hexachlorobenze (hexaCB)) has been developed using a headspace solid phase microextraction (HS-SPME) based on nano-structured ZnO combined with capillary gas chromatography-mass spectrometry (GC-MS). ZnO nanorods have been grown on fused silica fibers using a hydrothermal process. The diameter of ZnO nanorods was in the range of 50-80 nm. The effect of different variables on the extraction efficiency was studied simultaneously using an experimental design. The variables of interest in the HS-SPME were stirring rate, desorption time and temperature, ionic strength, extraction time and temperature. For this purpose, a multivariate strategy was applied based on an experimental design using a Plackett-Burman design for screening and a Box-Behnken design for optimizing of the significant factors. The detection limit and relative standard deviation (RSD) (n=5) for the target analytes were in the range of 0.01-0.1 ng L(-1) and 4.3-7.6%, respectively. The developed technique was found to be successfully applicable to preconcentration and determination of the target analytes in environmental water and soil samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Simultaneous determination of estrogenic odorant alkylphenols, chlorophenols, and their derivatives in water using online headspace solid phase microextraction coupled with gas chromatography-mass spectrometry.

    PubMed

    Yuan, Su-Fen; Liu, Ze-Hua; Lian, Hai-Xian; Yang, Chuangtao; Lin, Qing; Yin, Hua; Dang, Zhi

    2016-10-01

    A simple online headspace solid-phase microextraction (HS-SPME) coupled with the gas chromatography-mass spectrometry (GC-MS) method was developed for simultaneous determination of trace amounts of nine estrogenic odorant alkylphenols and chlorophenols and their derivatives in water samples. The extraction conditions of HS-SPME were optimized including fiber selection, extraction temperature, extraction time, and salt concentration. Results showed that divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber was the most appropriate one among the three selected commercial fibers, and the optimal extraction temperature, time, and salt concentration were 70 °C, 30 min, and 0.25 g/mL, respectively. The developed method was validated and showed good linearity (R (2) > 0.989), low limit of detection (LOD, 0.002-0.5 μg/L), and excellent recoveries (76-126 %) with low relative standard deviation (RSD, 0.7-12.9 %). The developed method was finally applied to two surface water samples and some of these target compounds were detected. All these detected compounds were below their odor thresholds, except for 2,4,6-TCAS and 2,4,6-TBAS wherein their concentrations were near their odor thresholds. However, in the two surface water samples, these detected compounds contributed to a certain amount of estrogenicity, which seemed to suggest that more attention should be paid to the issue of estrogenicity rather than to the odor problem.

  2. Coupled liquid chromatography-gas chromatography for the rapid analysis of gamma-oryzanol in rice lipids.

    PubMed

    Miller, Andreas; Frenzel, Thomas; Schmarr, Hans-Georg; Engel, Karl-Heinz

    2003-01-24

    An approach based on on-line coupled liquid chromatography-gas chromatography (LC-GC) was developed for the rapid analysis of gamma-oryzanol in rice. Total lipids were extracted from rice and subjected to LC-GC without any prior purification. gamma-Oryzanol was pre-separated by HPLC from rice lipids and transferred on-line to GC analysis in order to separate its major constituents. 24-methylenecycloartanyl ferulate, cycloartenyl ferulate, campesteryl ferulate, beta-sitosteryl ferulate and campestanyl ferulate. The identities of the compounds were confirmed by off-line GC-MS analysis. Total gamma-oryzanol content could be quantified by HPLC-UV detection and the distribution of gamma-oryzanol constituents could be determined by on-line coupled GC analysis. The proposed methodology paves the way for high-throughput investigations providing information on natural variations in gamma-oryzanol content and its composition in different rice varieties.

  3. Chromatographic instrumentation in space: past, present and future developments for exobiological studies

    NASA Astrophysics Data System (ADS)

    Raulin, F.; Sternberg, R.; Coscia, D.; Vidal-Madjar, C.; Millot, M.-C.; Sébille, B.; Israel, G.

    1999-01-01

    Several planetary exploration missions have already used chromatographic techniques to search for organic compounds, including complex organics, in extraterrestrial environments. So far, only gas chromatography (GC) has been used. In two cases (Viking and Cassini-Huygens), a Py-GC-MS instrument, coupling GC with a pyrolyzer and a mass spectrometer, has been flown. Powerful miniaturized Py-GC-MS instrumentation, with high resolution multi-GC columns and time-of-flight or Ion Trap mass spectrometers are under development, in the frame of the preparation of the Rosetta mission. There is now a strong need for new chromatographic instrumentation in space, in particular to perform detailed molecular analyses of complex non-volatile organics, including macromolecular compounds. Liquid Chromatography (LC), in particular High Performance Liquid Chromatography (HPLC) Supercritical Fluid Chromatography (SFC) or Chemical-Derivatization Gas Chromatography (CDGC) could provide a very efficient mean of analyzing a wide variety of exobiologically important compounds. LC or CDGC have never been used in space yet, but feasibility studies on their application in planetary mission are needed.

  4. Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

    NASA Technical Reports Server (NTRS)

    Holland, P.; Chutjian, A.; Darrach, M.; Orient, O.

    2002-01-01

    Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

  5. EPA Method 525.3 - Determination of Semivolatile Organic Chemicals in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS)

    EPA Science Inventory

    Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.

  6. Essential oil composition of five collections of Achillea biebersteinii from central Turkey and their antifungal and insecticidal activity

    USDA-ARS?s Scientific Manuscript database

    The composition of the essential oils hydrodistilled from the aerial parts of five Achillea biebersteinii Afan samples, collected in central Turkey from Konya, Isparta and Ankara, were analyzed both by gas chromatography (GC-FID) and gas chromatography-mass spectrometry (GC-MS). Eighty-four componen...

  7. Comparative Study of Three Achillea Essential Oils from Eastern Part of Turkey and their Biological Activities.

    USDA-ARS?s Scientific Manuscript database

    Essential oils obtained by hydrodistillation were analyzed both by gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). The main constituents found in Achillea oil were as follows: A. filipendulina Lam.: 43.8% santolina alcohol, 14.5% 1,8-cineole and 12.5% cis-chrysanthenyl acet...

  8. Trace analysis in the food and beverage industry by capillary gas chromatography: system performance and maintenance.

    PubMed

    Hayes, M A

    1988-04-01

    Gas chromatography (GC) is the most widely used analytical technique in the food and beverage industry. This paper addresses the problems of sample preparation and system maintenance to ensure the most sensitive, durable, and efficient results for trace analysis by GC in this industry.

  9. Gas-Purged Headspace Liquid Phase Microextraction System for Determination of Volatile and Semivolatile Analytes

    PubMed Central

    Zhang, Meihua; Bi, Jinhu; Yang, Cui; Li, Donghao; Piao, Xiangfan

    2012-01-01

    In order to achieve rapid, automatic, and efficient extraction for trace chemicals from samples, a system of gas-purged headspace liquid phase microextraction (GP-HS-LPME) has been researched and developed based on the original HS-LPME technique. In this system, semiconductor condenser and heater, whose refrigerating and heating temperatures were controlled by microcontroller, were designed to cool the extraction solvent and to heat the sample, respectively. Besides, inert gas, whose gas flow rate was adjusted by mass flow controller, was continuously introduced into and discharged from the system. Under optimized parameters, extraction experiments were performed, respectively, using GP-HS-LPME system and original HS-LPME technique for enriching volatile and semivolatile target compounds from the same kind of sample of 15 PAHs standard mixture. GC-MS analysis results for the two experiments indicated that a higher enrichment factor was obtained from GP-HS-LPME. The enrichment results demonstrate that GP-HS-LPME system is potential in determination of volatile and semivolatile analytes from various kinds of samples. PMID:22448341

  10. Comprehensive two-dimensional gas chromatography applied to illicit drug analysis.

    PubMed

    Mitrevski, Blagoj; Wynne, Paul; Marriott, Philip J

    2011-11-01

    Multidimensional gas chromatography (MDGC), and especially its latest incarnation--comprehensive two-dimensional gas chromatography (GC × GC)--have proved advantageous over and above classic one-dimensional gas chromatography (1D GC) in many areas of analysis by offering improved peak capacity, often enhanced sensitivity and, especially in the case of GC × GC, the unique feature of 'structured' chromatograms. This article reviews recent advances in MDGC and GC × GC in drug analysis with special focus on ecstasy, heroin and cocaine profiling. Although 1D GC is still the method of choice for drug profiling in most laboratories because of its simplicity and instrument availability, GC × GC is a tempting proposition for this purpose because of its ability to generate a higher net information content. Effluent refocusing due to the modulation (compression) process, combined with the separation on two 'orthogonal' columns, results in more components being well resolved and therefore being analytically and statistically useful to the profile. The spread of the components in the two-dimensional plots is strongly dependent on the extent of retention 'orthogonality' (i.e. the extent to which the two phases possess different or independent retention mechanisms towards sample constituents) between the two columns. The benefits of 'information-driven' drug profiling, where more points of reference are usually required for sample differentiation, are discussed. In addition, several limitations in application of MDGC in drug profiling, including data acquisition rate, column temperature limit, column phase orthogonality and chiral separation, are considered and discussed. Although the review focuses on the articles published in the last decade, a brief chronological preview of the profiling methods used throughout the last three decades is given.

  11. HS-SPME analysis of volatile organic compounds of coniferous needle litter

    NASA Astrophysics Data System (ADS)

    Isidorov, V. A.; Vinogorova, V. T.; Rafałowski, K.

    The composition of volatile emission of Scots pine ( Pinus sylvestris) and spruce ( Picea exelsa) litter was studied by gas chromatography-mass spectrometry (GC-MS) and samples were collected by solid-phase microextraction (SPME) method. The list of identified compounds includes over 60 organic substances of different classes. It was established that volatile emission contain not only components of essential oils of pine and spruce needles but also a large number of organic compounds which are probably secondary metabolites of litter-decomposing fungi. They include lower carbonyl compounds and alcohols as well as products of terpene dehydration and oxidation. These data show that the processes of litter decomposition are an important source of reactive organic compounds under canopy of coniferous forests.

  12. Volatile compounds of dry beans (Phaseolus vulgaris L.).

    PubMed

    Oomah, B Dave; Liang, Lisa S Y; Balasubramanian, Parthiba

    2007-12-01

    Volatile compounds of uncooked dry bean (Phaseolus vulgaris L.) cultivars representing three market classes (black, dark red kidney and pinto) grown in 2005 were isolated with headspace solid phase microextraction (HS-SPME), and analyzed with gas chromatography mass spectrometry (GC-MS). A total of 62 volatiles consisting of aromatic hydrocarbons, aldehydes, alkanes, alcohols and ketones represented on average 62, 38, 21, 12, and 9 x 10(6) total area counts, respectively. Bean cultivars differed in abundance and profile of volatiles. The combination of 18 compounds comprising a common profile explained 79% of the variance among cultivars based on principal component analysis (PCA). The SPME technique proved to be a rapid and effective method for routine evaluation of dry bean volatile profile.

  13. Headspace profiling of cocaine samples for intelligence purposes.

    PubMed

    Dujourdy, Laurence; Besacier, Fabrice

    2008-08-06

    A method for determination of residual solvents in illicit hydrochloride cocaine samples using static headspace-gas chromatography (HS-GC) associated with a storage computerized procedure is described for the profiling and comparison of seizures. The system involves a gas chromatographic separation of 18 occluded solvents followed by fully automatic data analysis and transfer to a PHP/MySQL database. First, a fractional factorial design was used to evaluate the main effects of some critical method parameters (salt choice, vial agitation intensity, oven temperature, pressurization and loop equilibration) on the results with a minimum of experiments. The method was then validated for tactical intelligence purposes (batch comparison) via several studies: selection of solvents and mathematical comparison tool, reproducibility and "cutting" influence studies. The decision threshold to determine the similarity of two samples was set and false positives and negatives evaluated. Finally, application of the method to distinguish geographical origins is discussed.

  14. Integrated Stable Isotope - Reactive Transport Model Approach for Assessment of Chlorinated Solvent Degradation

    DTIC Science & Technology

    2016-05-01

    Certification Program ETH Ethene GC Gas Chromatography GC-IRMS Gas Chromatography Isotope Ratio Mass Spectroscopy H Hydrogen IRMS Isotope...tool for attenuation of chlorinated solvents. The Demonstration Site was Operable Unit 10 at Hill AFB, Utah , a site where groundwater is impacted...techniques. The method involves extraction of the target compounds from environmental sample matrix, followed by separation of the compounds using gas

  15. Advanced method optimization for volatile aroma profiling of beer using two-dimensional gas chromatography time-of-flight mass spectrometry.

    PubMed

    Stefanuto, Pierre-Hugues; Perrault, Katelynn A; Dubois, Lena M; L'Homme, Benjamin; Allen, Catherine; Loughnane, Caitriona; Ochiai, Nobuo; Focant, Jean-François

    2017-07-21

    The complex mixture of volatile organic compounds (VOCs) present in the headspace of Trappist and craft beers was studied to illustrate the efficiency of thermal desorption (TD) comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC-TOFMS) for highlighting subtle differences between highly complex mixtures of VOCs. Headspace solid-phase microextraction (HS-SPME), multiple (and classical) stir bar sorptive extraction (mSBSE), static headspace (SHS), and dynamic headspace (DHS) were compared for the extraction of a set of 21 representative flavor compounds of beer aroma. A Box-Behnken surface response methodology experimental design optimization (DOE) was used for convex hull calculation (Delaunay's triangulation algorithms) of peak dispersion in the chromatographic space. The predicted value of 0.5 for the ratio between the convex hull and the available space was 10% higher than the experimental value, demonstrating the usefulness of the approach to improve optimization of the GC×GC separation. Chemical variations amongst aligned chromatograms were studied by means of Fisher Ratio (FR) determination and F-distribution threshold filtration at different significance levels (α=0.05 and 0.01) and based on z-score normalized area for data reduction. Statistically significant compounds were highlighted following principal component analysis (PCA) and hierarchical cluster analysis (HCA). The dendrogram structure not only provided clear visual information about similarities between products but also permitted direct identification of the chemicals and their relative weight in clustering. The effective coupling of DHS-TD-GC×GC-TOFMS with PCA and HCA was able to highlight the differences and common typical VOC patterns among 24 samples of different Trappist and selected Canadian craft beers. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. A modified multiscale peak alignment method combined with trilinear decomposition to study the volatile/heat-labile components in Ligusticum chuanxiong Hort - Cyperus rotundus rhizomes by HS-SPME-GC/MS.

    PubMed

    He, Min; Yan, Pan; Yang, Zhi-Yu; Zhang, Zhi-Min; Yang, Tian-Biao; Hong, Liang

    2018-03-15

    Head Space/Solid Phase Micro-Extraction (HS-SPME) coupled with Gas Chromatography/Mass Spectrometer (GC/MS) was used to determine the volatile/heat-labile components in Ligusticum chuanxiong Hort - Cyperus rotundus rhizomes. Facing co-eluting peaks in k samples, a trilinear structure was reconstructed to obtain the second-order advantage. The retention time (RT) shift with multi-channel detection signals for different samples has been vital in maintaining the trilinear structure, thus a modified multiscale peak alignment (mMSPA) method was proposed in this paper. The peak position and peak width of representative ion profile were firstly detected by mMSPA using Continuous Wavelet Transform with Haar wavelet as the mother wavelet (Haar CWT). Then, the raw shift was confirmed by Fast Fourier Transform (FFT) cross correlation calculation. To obtain the optimal shift, Haar CWT was again used to detect the subtle deviations and be amalgamated in calculation. Here, to ensure there is no peaks shape alternation, the alignment was performed in local domains of data matrices, and all data points in the peak zone were moved via linear interpolation in non-peak parts. Finally, chemical components of interest in Ligusticum chuanxiong Hort - Cyperus rotundus rhizomes were analyzed by HS-SPME-GCMS and mMSPA-alternating trilinear decomposition (ATLD) resolution. As a result, the concentration variation between herbs and their pharmaceutical products can provide a scientific basic for the quality standard establishment of traditional Chinese medicines. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Analyzing Inquiry Questions of High-School Students in a Gas Chromatography Open-Ended Laboratory Experiment

    ERIC Educational Resources Information Center

    Blonder, Ron; Mamlock-Naaman, Rachel; Hofstein, Avi

    2008-01-01

    This paper describes the implementation of an open-ended inquiry experiment for high-school students, based on gas chromatography (GC). The research focuses on identifying the level of questions that students ask during the GC open inquiry laboratory, and it examines whether implementing the advanced inquiry laboratory opens up new directions for…

  18. Review of recent developments and applications in low-pressure (vacuum outlet) gas chromatography

    USDA-ARS?s Scientific Manuscript database

    The concept of low pressure (LP) vacuum outlet gas chromatography (GC) was introduced more than 50 years ago, but it was not until the 2000s that its theoretical applicability to fast analysis of GC-amenable chemicals was realized. In practice, LPGC is implemented by placing the outlet of a short, ...

  19. Gas chromatography-mass spectrometry (GC-MS) analysis of extractives of naturally durable wood

    Treesearch

    G.T. Kirker; A.B. Blodgett; S.T. Lebow; C.A. Clausen

    2011-01-01

    A preliminary study to evaluate naturally durable wood species in an above ground field trial using Gas Chromatography-Mass Spectrometry (GC-MS) detected differences in fatty acid extractives between species and within the same species over time. Fatty acids were extracted with chloroform: methanol mixture then methylated with sodium methoxide and fractionated using...

  20. Detection of volatile spoilage metabolites in fermented cucumbers using nontargeted, comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS)

    USDA-ARS?s Scientific Manuscript database

    A nontargeted, comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS) method was developed for the analysis of fermented cucumber volatiles before and after anaerobic spoilage. Volatiles extracted by solid-phase microextraction were separated on a polyethyle...

  1. METHOD 530 DETERMINATION OF SELECT SEMIVOLATILE ORGANIC CHEMICALS IN DRINKING WATER BY SOLID PHASE EXTRACTION AND GAS CHROMATOGRAPHY/ MASS SPECTROMETRY (GC/MS)

    EPA Science Inventory

    1.1. This is a gas chromatography/mass spectrometry (GC/MS) method for the determination of selected semivolatile organic compounds in drinking waters. Accuracy and precision data have been generated in reagent water, and in finished ground and surface waters for the compounds li...

  2. Gas Chromatography Analysis with Olfactometric Detection (GC-O) as a Useful Methodology for Chemical Characterization of Odorous Compounds

    PubMed Central

    Brattoli, Magda; Cisternino, Ezia; Dambruoso, Paolo Rosario; de Gennaro, Gianluigi; Giungato, Pasquale; Mazzone, Antonio; Palmisani, Jolanda; Tutino, Maria

    2013-01-01

    The gas chromatography-olfactometry (GC-O) technique couples traditional gas chromatographic analysis with sensory detection in order to study complex mixtures of odorous substances and to identify odor active compounds. The GC-O technique is already widely used for the evaluation of food aromas and its application in environmental fields is increasing, thus moving the odor emission assessment from the solely olfactometric evaluations to the characterization of the volatile components responsible for odor nuisance. The aim of this paper is to describe the state of the art of gas chromatography-olfactometry methodology, considering the different approaches regarding the operational conditions and the different methods for evaluating the olfactometric detection of odor compounds. The potentials of GC-O are described highlighting the improvements in this methodology relative to other conventional approaches used for odor detection, such as sensoristic, sensorial and the traditional gas chromatographic methods. The paper also provides an examination of the different fields of application of the GC-O, principally related to fragrances and food aromas, odor nuisance produced by anthropic activities and odorous compounds emitted by materials and medical applications. PMID:24316571

  3. Development and validation of a fast static headspace GC method for determination of residual solvents in permethrin.

    PubMed

    Tian, Jingzhi; Rustum, Abu

    2016-09-05

    A fast static headspace gas chromatography (HS-GC) method was developed to separate all residual solvents present in commercial active pharmaceutical ingredient (API) batches of permethrin. A total of six residual solvents namely 2-methylpentane, 3-methylpentane, methylcyclopentane, n-hexane, cyclohexane and toluene were found in typical commercial batches of permethrin; and three of them are not in the list of ICH solvents. All six residual solvents were baseline separated in five minutes by the new method presented in this paper. The method was successfully validated as per International Conference on Harmonisation (ICH) guidelines. Evaluation of this method was conducted to separate 26 commonly used solvents in the manufacturing of various APIs, key intermediates of APIs and pharmaceutical excipients. The results of the evaluation demonstrated that this method can also be used as a general method to determine residual solvents in various APIs, intermediates and excipients that are used in pharmaceutical products. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Global volatile profile of virgin olive oils flavoured by aromatic/medicinal plants.

    PubMed

    Perestrelo, R; Silva, C; Silva, P; Câmara, J S

    2017-07-15

    The global volatile profile of commercial virgin olive oils and flavoured olive oils with aromatic/medicinal plants, was established using liquid-liquid microextraction (LLME) and headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-quadrupole mass spectrometry (GC-qMS). More than 60 volatile organic compounds (VOCs belonging to different groups were identified using both methods. Olive oils volatile profile was slightly influenced by maceration process, which occurred at room temperature (20±2°C) for 15days. The predominant differences were observed in terpenoids group, since some of them were only identified in the flavoured olive oils, while others showed an increase with the maceration process. VOCs mass transfer from plants to olive oils could explain the observed results. Principal components analysis (PCA) applied to LLME/GC-qMS data allowed to distinguish the olive oils. The flavoured oils would increase the use of olive oil among consumers as consequence of the improvement of its aromatic profile and healthy properties. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Development of an Exhaled Breath Monitoring System with Semiconductive Gas Sensors, a Gas Condenser Unit, and Gas Chromatograph Columns

    PubMed Central

    Itoh, Toshio; Miwa, Toshio; Tsuruta, Akihiro; Akamatsu, Takafumi; Izu, Noriya; Shin, Woosuck; Park, Jangchul; Hida, Toyoaki; Eda, Takeshi; Setoguchi, Yasuhiro

    2016-01-01

    Various volatile organic compounds (VOCs) in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS) for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls), and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls). The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis. PMID:27834896

  6. [Recent advances in analysis of petroleum geological samples by comprehensive two-dimensional gas chromatography].

    PubMed

    Gao, Xuanbo; Chang, Zhenyang; Dai, Wei; Tong, Ting; Zhang, Wanfeng; He, Sheng; Zhu, Shukui

    2014-10-01

    Abundant geochemical information can be acquired by analyzing the chemical compositions of petroleum geological samples. The information obtained from the analysis provides scientifical evidences for petroleum exploration. However, these samples are complicated and can be easily influenced by physical (e. g. evaporation, emulsification, natural dispersion, dissolution and sorption), chemical (photodegradation) and biological (mainly microbial degradation) weathering processes. Therefore, it is very difficult to analyze the petroleum geological samples and they cannot be effectively separated by traditional gas chromatography/mass spectrometry. A newly developed separation technique, comprehensive two-dimensional gas chromatography (GC x GC), has unique advantages in complex sample analysis, and recently it has been applied to petroleum geological samples. This article mainly reviews the research progres- ses in the last five years, the main problems and the future research about GC x GC applied in the area of petroleum geology.

  7. Headspace Gas Chromatography Method for Studies of Reaction and Permeation of Volatile Agents with Solid Materials

    DTIC Science & Technology

    2015-01-01

    HEADSPACE GAS CHROMATOGRAPHY METHOD FOR STUDIES OF REACTION AND PERMEATION OF...TITLE AND SUBTITLE Headspace Gas Chromatography Method for Studies of Reaction and Permeation of Volatile Agents with Solid Materials 5a...method is described for measuring the reactivity and permeability of fabrics, films, and other solid materials. Headspace gas chromatography (GC)

  8. Three-way principal component analysis of the volatile fraction by HS-SPME/GC of aceto balsamico tradizionale of modena.

    PubMed

    Cocchi, Marina; Durante, Caterina; Grandi, Margherita; Manzini, Daniela; Marchetti, Andrea

    2008-01-15

    The present research is aimed at monitoring the evolution of the volatile organic compounds of different samples of aceto balsamico tradizionale of modena (ABTM) during ageing. The flavouring compounds, headspace fraction, of the vinegars of four batterie were sampled by solid phase microextraction technique (SPME), and successively analysed by gas chromatography. Obtaining a data set characterized by different sources of variability such as, different producers, samples of different age and chromatographic profile. The gas chromatographic signals were processed by a three-way data analysis method (Tucker3), which allows an easy visualisation of the data by furnishing a distinct set of graphs for each source of variability. The obtained results indicate that the samples can be separated according to their age highlighting the chemical constituents, which play a major role for their differentiation. The present study represents an example of how the application of Tucker3 models, on gas chromatographic signals may help to follow the transformation processes of food products.

  9. Investigation of Pinus mugo essential oil oxygenated fraction by combined use of gas chromatography and dry column chromatography.

    PubMed

    A, M B; Coran, S A; Giannellini, V; Vincieri, F F; Moneti, G

    1981-09-01

    The oxygenated compounds of Pinus mugo Turra essential oil were investigated by a combination of GC and dry column chromatography (DCC) coordinated by GC data processing. The collected data resulted in a bar graph ("normalized" gas chromatogram) giving the RRT's and relative amounts of 68 components; 38 of them were identified by MS and IR. The described procedure may be used for essential oil analysis in general.

  10. GC/MS Analysis of the Essential Oil of Vernonia cinerea.

    PubMed

    Joshi, Rajesh K

    2015-07-01

    The hydro-distilled essential oil obtained from the roots of V. cinerea Less. (Asteraceae) was investigated by gas chromatography equipped with flame ionization detector (GC-FID) and gas chromatography coupled with mass spectrometry (GC/MS). Twenty-five constituents were identified, which represented 97.4% of the total oil. The major compounds were α-muurolene (30.7%), β-caryophyllene (9.6%), α-selinene (8.7%), cyperene (6.7%) and α-gurjunene (6.5%). The essential oil was dominated by sesquiterpene hydrocarbons (87.8%).

  11. Application of gas chromatography/flame ionization detector-based metabolite fingerprinting for authentication of Asian palm civet coffee (Kopi Luwak).

    PubMed

    Jumhawan, Udi; Putri, Sastia Prama; Yusianto; Bamba, Takeshi; Fukusaki, Eiichiro

    2015-11-01

    Development of authenticity screening for Asian palm civet coffee, the world-renowned priciest coffee, was previously reported using metabolite profiling through gas chromatography/mass spectrometry (GC/MS). However, a major drawback of this approach is the high cost of the instrument and maintenance. Therefore, an alternative method is needed for quality and authenticity evaluation of civet coffee. A rapid, reliable and cost-effective analysis employing a universal detector, GC coupled with flame ionization detector (FID), and metabolite fingerprinting has been established for discrimination analysis of 37 commercial and non-commercial coffee beans extracts. gas chromatography/flame ionization detector (GC/FID) provided higher sensitivity over a similar range of detected compounds than GC/MS. In combination with multivariate analysis, GC/FID could successfully reproduce quality prediction from GC/MS for differentiation of commercial civet coffee, regular coffee and coffee blend with 50 wt % civet coffee content without prior metabolite details. Our study demonstrated that GC/FID-based metabolite fingerprinting can be effectively actualized as an alternative method for coffee authenticity screening in industries. Copyright © 2015. Published by Elsevier B.V.

  12. Comparison of different mass spectrometry techniques in the measurement of L-[ring-13C6]phenylalanine incorporation into mixed muscle proteins

    PubMed Central

    Zabielski, Piotr; Ford, G. Charles; Persson, X. Mai; Jaleel, Abdul; Dewey, Jerry D.; Nair, K Sreekumaran

    2013-01-01

    Precise measurement of low enrichment of stable isotope labeled amino-acid tracers in tissue samples is a prerequisite in measuring tissue protein synthesis rates. The challenge of this analysis is augmented when small sample size is a critical factor. Muscle samples from human participants following an 8 hour intravenous infusion of L-[ring-13C6]phenylalanine and a bolus dose of L-[ring-13C6]phenylalanine in a mouse were utilized. Liquid Chromatography tandem mass spectrometry (LC/MS/MS), Gas Chromatography tandem mass spectrometry (GC/MS/MS) and Gas Chromatography/Mass spectrometry (GC/MS) were compared to the Gas Chromatography-Combustion-Isotope Ratio mass spectrometry (GC/C/IRMS), to measure mixed muscle protein enrichment of [ring13C6]phenylalanine enrichment. The sample isotope enrichment ranged from 0.0091 to 0.1312 Molar Percent excess (MPE). As compared with GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS showed coefficients of determination of R2 = 0.9962 and R2 = 0.9942, and 0.9217 respectively. However, the precision of measurements (coefficients of variation) for intra-assay are 13.0%, 1.7%, 6.3% and 13.5% and for inter-assay are 9.2%, 3.2%, 10.2% and 25% for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS respectively. The muscle sample sizes required to obtain these results were 8μg, 0.8μg, 3μg and 3μg for GC/C/IRMS, LC/MS/MS, GC/MS/MS, and GC/MS respectively. We conclude that LC/MS/MS is optimally suited for precise measurements of L-[ring-13C6]phenylalanine tracer enrichment in low abundance and in small quantity samples. PMID:23378099

  13. The Use of Gas Chromatography and Mass Spectrometry to Introduce General Chemistry Students to Percent Mass and Atomic Mass Calculations

    ERIC Educational Resources Information Center

    Pfennig, Brian W.; Schaefer, Amy K.

    2011-01-01

    A general chemistry laboratory experiment is described that introduces students to instrumental analysis using gas chromatography-mass spectrometry (GC-MS), while simultaneously reinforcing the concepts of mass percent and the calculation of atomic mass. Working in small groups, students use the GC to separate and quantify the percent composition…

  14. Rapid method for the simultaneous detection of boar taint compounds by means of solid phase microextraction coupled to gas chromatography/mass spectrometry.

    PubMed

    Verplanken, Kaat; Wauters, Jella; Van Durme, Jim; Claus, Dirk; Vercammen, Joeri; De Saeger, Sarah; Vanhaecke, Lynn

    2016-09-02

    Because of animal welfare issues, the voluntary ban on surgical castration of male piglets, starting January 2018 was announced in a European Treaty. One viable alternative is the fattening of entire male pigs. However, this can cause negative consumer reactions due to the occurrence of boar taint and possibly lead to severe economic losses in pig husbandry. In this study, headspace solid phase microextraction (HS-SPME) coupled to GC-MS was used in the development and optimization of a candidate method for fast and accurate detection of the boar taint compounds. Remarkably fast extraction (45s) of the boar taint compounds from adipose tissue was achieved by singeing the fat with a soldering iron while released volatiles were extracted in-situ using HS-SPME. The obtained method showed good performance characteristics after validation according to CD 2002/657/EC and ISO/IEC 17025 guidelines. Moreover, cross-validation with an in-house UHPLC-HR-Orbitrap-MS method showed good agreement between an in-laboratory method and the new candidate method for the fast extraction and detection of skatole and androstenone, which emphasizes the accuracy of this new SPME-GC-MS method. Threshold detection of the boar taint compounds on a portable GC-MS could not be achieved. However, despite the lack of sensitivity obtained on the latter instrument, a very fast method with run-to-run time of 3.5min for the detection of the boar taint compounds was developed. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Environmental assessment of a watertube boiler firing a coal-water slurry. Volume 2. Data supplement. Final report, January 1984-March 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRosier, R.; Waterland, L.R.

    1986-02-01

    This report is a compendium of detailed test sampling and analysis data obtained in field tests of a watertube industrial boiler burning a coal/water slurry (CWS). Test data reported include preliminary stack test data, boiler operating data, and complete flue-gas emission results. Flue-gas emission measurements included continuous monitoring for criteria pollutants; onsite gas chromatography (GC) for volatile hydrocarbons (Cl-C6); Methods 5/8 sampling for particulate, SO/sub 2/, and SO/sub 3/ emissions; source assessment sampling system (SASS) for total organics in two boiling point ranges (100 to 300 C and > 300 C), organic compound category information using infrared spectrometry (IR), liquidmore » column (LC) chromatography separation, and low-resolution mass spectrometry (LRMS), specific quantitation of the semivolatile organic priority pollutants using gas chromatography/mass spectrometry (GC/MS), and trace-element emissions using spark-source mass spectrometry (SSMS) and atomic absorption spectroscopy (AAS); N/sub 2/O emissions by gas chromatography/electron-capture detector (GC/ECD); and biological assay testing of SASS and ash-stream samples.« less

  16. Non-destructive profiling of volatile organic compounds using HS-SPME/GC-MS and its application for the geographical discrimination of white rice.

    PubMed

    Lim, Dong Kyu; Mo, Changyeun; Lee, Dong-Kyu; Long, Nguyen Phuoc; Lim, Jongguk; Kwon, Sung Won

    2018-01-01

    The authenticity determination of white rice is crucial to prevent deceptive origin labeling and dishonest trading. However, a non-destructive and comprehensive method for rapidly discriminating the geographical origins of white rice between countries is still lacking. In the current study, we developed a volatile organic compound based geographical discrimination method using headspace solid-phase microextraction coupled to gas chromatography-mass spectrometry (HS-SPME/GC-MS) to discriminate rice samples from Korea and China. A partial least squares discriminant analysis (PLS-DA) model exhibited a good classification of white rice between Korea and China (accuracy = 0.958, goodness of fit = 0.937, goodness of prediction = 0.831, and permutation test p-value = 0.043). Combining the PLS-DA based feature selection with the differentially expressed features from the unpaired t-test and significance analysis of microarrays, 12 discriminatory biomarkers were found. Among them, hexanal and 1-hexanol have been previously known to be associated with the cultivation environment and storage conditions. Other hydrocarbon biomarkers are novel, and their impact on rice production and storage remains to be elucidated. In conclusion, our findings highlight the ability to rapidly discriminate white rice from Korea and China. The developed method maybe useful for the authenticity and quality control of white rice. Copyright © 2017. Published by Elsevier B.V.

  17. Characterisation of the volatile profile of coconut water from five varieties using an optimised HS-SPME-GC analysis.

    PubMed

    Prades, Alexia; Assa, Rebecca Rachel Ablan; Dornier, Manuel; Pain, Jean-Pierre; Boulanger, Renaud

    2012-09-01

    Coconut (Cocos nucifera L.) water is a refreshing tropical drink whose international market has recently been growing. However, little is yet known about its physicochemical composition, particularly its aroma. This study set out to characterise the volatile profile of water from five coconut varieties. Aroma compounds were characterised by headspace solid phase microextraction gas chromatography (HS-SPME-GC) analysis. An experimental design was established to optimise SPME conditions, leading to an equilibration time of 10 min followed by an extraction time of 60 min at 50 °C. Accordingly, immature coconut water from WAT (West African Tall), PB121 (MYD × WAT Hybrid), MYD (Malayan Yellow Dwarf), EGD (Equatorial Guinea Green Dwarf) and THD (Thailand Aromatic Green Dwarf) palms was analysed and described. Ketones were mainly present in the Tall and Hybrid varieties, whereas aldehydes were most abundant in the Dwarf palms. Tall coconut water was characterised by a high lactone content. THD exhibited a high ethyl octanoate level. The cluster analysis of the volatile fraction from the five coconut cultivars was found to be related to their genetic classification. The volatile compounds of immature coconut water from five varieties were characterised for the first time. Volatile profile analysis could be a useful tool for the selection of Dwarf coconut varieties, which are mainly consumed as a beverage. Copyright © 2012 Society of Chemical Industry.

  18. Flow-switching device for comprehensive two-dimensional gas chromatography.

    PubMed

    Bueno, Pedro A; Seeley, John V

    2004-02-20

    A simple flow-switching device has been developed as a differential flow modulator for comprehensive two-dimensional gas chromatography (GC x GC). The device is assembled from tubing, four tee unions, and a solenoid valve. The solenoid valve is located outside the oven of the gas chromatograph and is not in the sample path. The modulation technique has no inherent temperature restrictions and passes 100% of the primary column effluent to the secondary column(s). Secondary peaks are produced with widths at half maximum less than 100 ms when operating in GC x 2GC mode with a 2.0 s modulation period. The efficacy of this approach is demonstrated through the analysis of a standard mixture of volatile organic compounds (VOCs) and diesel fuel.

  19. Can volatile organic metabolites be used to simultaneously assess microbial and mite contamination level in cereal grains and coffee beans?

    PubMed

    Salvador, Angelo C; Baptista, Inês; Barros, António S; Gomes, Newton C M; Cunha, Angela; Almeida, Adelaide; Rocha, Silvia M

    2013-01-01

    A novel approach based on headspace solid-phase microextraction (HS-SPME) combined with comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC×GC-ToFMS) was developed for the simultaneous screening of microbial and mite contamination level in cereals and coffee beans. The proposed approach emerges as a powerful tool for the rapid assessment of the microbial contamination level (ca. 70 min versus ca. 72 to 120 h for bacteria and fungi, respectively, using conventional plate counts), and mite contamination (ca. 70 min versus ca. 24 h). A full-factorial design was performed for optimization of the SPME experimental parameters. The methodology was applied to three types of rice (rough, brown, and white rice), oat, wheat, and green and roasted coffee beans. Simultaneously, microbiological analysis of the samples (total aerobic microorganisms, moulds, and yeasts) was performed by conventional plate counts. A set of 54 volatile markers was selected among all the compounds detected by GC×GC-ToFMS. Principal Component Analysis (PCA) was applied in order to establish a relationship between potential volatile markers and the level of microbial contamination. Methylbenzene, 3-octanone, 2-nonanone, 2-methyl-3-pentanol, 1-octen-3-ol, and 2-hexanone were associated to samples with higher microbial contamination level, especially in rough rice. Moreover, oat exhibited a high GC peak area of 2-hydroxy-6-methylbenzaldehyde, a sexual and alarm pheromone for adult mites, which in the other matrices appeared as a trace component. The number of mites detected in oat grains was correlated to the GC peak area of the pheromone. The HS-SPME/GC×GC-ToFMS methodology can be regarded as the basis for the development of a rapid and versatile method that can be applied in industry to the simultaneous assessment the level of microbiological contamination and for detection of mites in cereals grains and coffee beans.

  20. Influence of enzymatic extrusion liquefaction pretreatment for Chinese rice wine on the volatiles generated from extruded rice.

    PubMed

    Xu, Enbo; Li, Hongyan; Wu, Zhengzong; Wang, Fang; Xu, Xueming; Jin, Zhengyu; Jiao, Aiquan

    2015-01-01

    Volatile compounds in enzymatic extruded rice, produced under different conditions of varying barrel temperature (BT), α-amylase concentration (AC) and moisture content (MC), were extracted and identified by headspace solid phase microextraction (HS-SPME) and gas chromatography-linked mass spectrometry (GC-MS). Statistical analyses reflected that the Maillard reaction could be inhibited both by the mild extrusion conditions and the enhanced hydrolysis caused by thermostable α-amylase. Relative amounts of total volatiles in enzymatic extruded rice were far less than those in severe processed extruded rice. Reverse-phase high-performance liquid chromatography (RP-HPLC) showed that the amino acids (AAs) involved in Maillrad reaction were utmostly preserved in extruded rice with highest amylase concentration by comparison of total AA content of different extrudates. These results suggest that enzymatic extrusion liquefaction is an effective way to control the generation of volatiles from extruded rice for Chinese rice wine production. © 2014 Institute of Food Technologists®

  1. Study of chemical stability of lemon oil components in sodium caseinate-lactose glycoconjugate-stabilized oil-in-water emulsions using solid-phase microextraction-gas chromatography.

    PubMed

    Sabik, Hassan; Achouri, Allaoua; Alfaro, Maria; Pelletier, Marylène; Belanger, Denis; Britten, Michel; Fustier, Patrick

    2014-07-25

    A headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-mass spectrometry (GC/MS) method was developed to quantify lemon oil components and their degradation products in oil-in-water (O/W) emulsions prepared with sodium caseinate-heated-lactose (NaC-T + Lact) glycoconjugates as wall materials at two pH values (3.0 and 6.8). NaC-T + Lact conjugates had a significantly lower solubility at both pHs. Hydrolysis prior to glycation enhanced the solubility of glycoconjugates. Glycation with lactose did not improve the emulsion activity of NaC, while caseinate glycoconjugates showed much stronger antioxidant activity than the NaC-control sample. This might be due to the presence of melanoidins formed between the sugar and amino acid compounds as supported by the increase in browning intensity. Among the SPME-fibres tested, carboxen/polydimethylsiloxane (CAR/PDMS) provided better results in terms of sensitivity and selectivity for oil lemon components and their degradation products. Storage studies of these emulsions demonstrated that glycated NaC-T + Lact showed protection against peroxidation compared to the control. However, acidic pH conditions altered their stability over storage time. The major off-flavor components (α-terpineol and carvone) were inhibited in emulsions stabilized with glycated NaC, particularly at pH 6.8. The use of NaC-T + Lact conjugates showed improved encapsulation efficiency and stability and could be used as potential food ingredient-emulsifiers for stabilising citrus oils against oxidative degradation in food and beverage applications.

  2. Headspace gas chromatography with flame ionization detection (HS-GC-FID) for the determination of dissolved methane in wastewater.

    PubMed

    Beale, D J; Tjandraatmadja, G; Toifl, M; Goodman, N

    2014-01-01

    There is currently a need for a simple, accurate and reproducible method that quantifies the amount of dissolved methane in wastewater in order to realize the potential methane that can be recovered and account for any emissions. This paper presents such a method, using gas chromatography with flame ionization detection fitted with a GS-Gas PRO column coupled with a headspace auto sampler. A practical limit of detection for methane of 0.9 mg L(-1), with a retention time of 1.24 min, was obtained. It was found that the reproducibility and accuracy of the method increased significantly when samples were collected using an in-house constructed bailer sampling device and with the addition of 100 μL hydrochloric acid (HCl) and 25% sodium chloride (NaCl) and sonication for 30 min prior to analysis. Analysis of wastewater samples and wastewater sludge collected from a treatment facility were observed to range from 12.51 to 15.79 mg L(-1) (relative standard deviation (RSD) 8.1%) and 17.56 to 18.67 mg L(-1) (RSD 3.4%) respectively. The performance of this method was validated by repeatedly measuring a mid-level standard (n=8; 10 mg L(-1)), with an observed RSD of 4.6%.

  3. The multi-mode modulator: A versatile fluidic device for two-dimensional gas chromatography.

    PubMed

    Seeley, John V; Schimmel, Nicolaas E; Seeley, Stacy K

    2018-02-09

    A fluidic device called the multi-mode modulator (MMM) has been developed for use as a comprehensive two-dimensional gas chromatography (GC x GC) modulator. The MMM can be employed in a wide range of capacities including as a traditional heart-cutting device, a low duty cycle GC x GC modulator, and a full transfer GC x GC modulator. The MMM is capable of producing narrow component pulses (widths <50ms) while operating at flows compatible with high resolution chromatography. The sample path of modulated components is confined to the interior of a joining capillary. The joining capillary dimensions and the position of the columns within the joining capillary can be optimized for the selected modulation mode. Furthermore, the joining capillary can be replaced easily and inexpensively if it becomes fouled due to sample matrix components or column bleed. The principles of operation of the MMM are described and its efficacy is demonstrated as a heart-cutting device and as a GC x GC modulator. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Dehydration of Methylcyclohexanol Isomers in the Undergraduate Organic Laboratory and Product Analysis by Gas Chromatography-Mass Spectroscopy (GC-MS)

    ERIC Educational Resources Information Center

    Clennan, Malgorzata M.; Clennan, Edward L.

    2011-01-01

    Dehydrations of "cis"- and "trans"-2-methylcyclohexanol mixtures were carried out with 60% sulfuric acid at 78-80 [degrees]C as a function of time and the products were identified by gas chromatography-mass spectroscopy (GC-MS) analysis. The compounds identified in the reaction mixtures include alkenes, 1-, 3-, and 4-methylcyclohexenes and…

  5. Quantitative Analysis of Bisphenol A Leached from Household Plastics by Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry (SPME-GC-MS)

    ERIC Educational Resources Information Center

    Johnson, Bettie Obi; Burke, Fernanda M.; Harrison, Rebecca; Burdette, Samantha

    2012-01-01

    The measurement of trace levels of bisphenol A (BPA) leached out of household plastics using solid-phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS) is reported here. BPA is an endocrine-disrupting compound used in the industrial manufacture of polycarbonate plastic bottles and epoxy resin can liners. This experiment…

  6. Chemical composition, larvicidal, and biting deterrent activity of essential oils of two subspecies of Tanacetum argenteum (Asterales: Asteraceae) and individual constituents against Aedes aegypti (Diptera: Culicidae)

    USDA-ARS?s Scientific Manuscript database

    Water distilled essential oils from the air dried aerial parts of Tanacetum argenteum (Lam.) Willd. subsp. argenteum (Lam.) and T. argenteum (Lam.) Willd. subsp. canum (C. Koch) Grierson were analyzed by gas chromatography (GC-FID) and gas chromatography-mass spectrometry (GC-MS). Twenty-seven and 3...

  7. Innovative Technology Development for Comprehensive Air Quality Characterization from Open Burning

    DTIC Science & Technology

    2012-04-01

    Burning/Open Detonation (OB/OD) has been used as a safe, effective , and economic way to demilitarize munitions for energetic material disposal. Field...target analyte i (lb/lb i in ordnance) ERDC-CERL Engineer Research Development Center, Construction Engineering Research Laboratory GC/FID gas ...chromatograph(y) - flame ionization detector GC/MS gas chromatography/mass spectrometry GPS global positioning system ISO International Organization for

  8. A Laboratory Experiment To Measure Henry's Law Constants of Volatile Organic Compounds with a Bubble Column and a Gas Chromatography Flame Ionization Detector (GC-FID)

    ERIC Educational Resources Information Center

    Lee, Shan-Hu; Mukherjee, Souptik; Brewer, Brittany; Ryan, Raphael; Yu, Huan; Gangoda, Mahinda

    2013-01-01

    An undergraduate laboratory experiment is described to measure Henry's law constants of organic compounds using a bubble column and gas chromatography flame ionization detector (GC-FID). This experiment is designed for upper-division undergraduate laboratory courses and can be implemented in conjunction with physical chemistry, analytical…

  9. Comprehensive Urine Drug Screen by Gas Chromatography/Mass Spectrometry (GC/MS).

    PubMed

    Ramoo, Bheemraj; Funke, Melissa; Frazee, Clint; Garg, Uttam

    2016-01-01

    Drug screening is an essential component of clinical toxicology laboratory service. Some laboratories use only automated chemistry analyzers for limited screening of drugs of abuse and few other drugs. Other laboratories use a combination of various techniques such as immunoassays, colorimetric tests, and mass spectrometry to provide more detailed comprehensive drug screening. Mass spectrometry, gas or liquid, can screen for hundreds of drugs and is often considered the gold standard for comprehensive drug screening. We describe an efficient and rapid gas chromatography/mass spectrometry (GC/MS) method for comprehensive drug screening in urine which utilizes a liquid-liquid extraction, sample concentration, and analysis by GC/MS.

  10. [Simultaneous determination of seven residual solvents in bovis calculus artifactus by headspace gas chromatography].

    PubMed

    Chi, Shuyao; Wu, Dike; Sun, Jinhong; Ye, Ruhan; Wang, Xiaoyan

    2014-05-01

    A headspace gas chromatography (HS-GC) method was developed for the simultaneous determination of seven residual solvents (petroleum ether (60-90 degrees C), acetone, ethyl acetate, methanol, methylene chloride, ethanol and butyl acetate) in bovis calculus artifactus. The DB-WAX capillary column and flame ionization detector (FID) were used for the separation and detection of the residual solvents, and the internal standard method was used for the quantification. The chromatographic conditions, such as equilibrium temperature and equilibrium time, were optimized. Under the optimized conditions, all of the seven residual solvents showed good linear relationships with good correlation coefficients (not less than 0.999 3) in the prescribed concentration range. At three spiked levels, the recoveries for the seven residual solvents were 94.7%-105.2% with the relative standard deviations (RSDs) less than 3.5%. The limits of detection (LODs) of the method were 0.43-5.23 mg/L, and the limits of quantification (LOQs) were 1.25-16.67 mg/L. The method is simple, rapid, sensitive and accurate, and is suitable for the simultaneous determination of the seven residual solvents in bovis calculus artifactus.

  11. Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Qian, Michael C.

    Gas chromatography (GC) has many applications in the analysis of food products. GC has been used for the determination of fatty acids, triglycerides, cholesterol, gases, water, alcohols, pesticides, flavor compounds, and many more. While GC has been used for other food components such as sugars, oligosaccharides, amino acids, peptides, and vitamins, these substances are more suited to analysis by high performance liquid chromatography. GC is ideally suited to the analysis of volatile substances that are thermally stable. Substances such as pesticides and flavor compounds that meet these criteria can be isolated from a food and directly injected into the GC. For compounds that are thermally unstable, too low in volatility, or yield poor chromatographic separation due to polarity, a derivatization step must be done before GC analysis. The two parts of the experiment described here include the analysis of alcohols that requires no derivatization step, and the analysis of fatty acids which requires derivatization. The experiments specify the use of capillary columns, but the first experiment includes conditions for a packed column.

  12. HS-GC/MS volatile profile of different varieties of garlic and their behavior under heating.

    PubMed

    Molina-Calle, María; Priego-Capote, Feliciano; de Castro, María D Luque

    2016-05-01

    Garlic is one of the most used seasonings in the world whose beneficial health effects, mainly ascribed to organosulfur compounds, are shared with the rest of the Allium family. The fact that many of these compounds are volatile makes the evaluation of the volatile profile of garlic interesting. For this purpose, three garlic varieties-White, Purple, and Chinese-cultivated in the South of Spain were analyzed by a method based on a headspace (HS) device coupled to a gas chromatograph and mass detector (HS-GC/MS). The main temperatures in the HS were optimized to achieve the highest concentration of volatiles. A total number of 45 volatiles were tentatively identified (among them 17 were identified for the first time in garlic); then, all were classified, also for the first time, and their relative concentration in three garlic varieties was used to evaluate differences among them and to study their profiles according to the heating time. Chinese garlic was found to be the richest variety in sulfur volatiles, while the three varieties presented a similar trend under preset heating times allowing differentiation between varieties and heating time using principal component analysis. Graphical Abstract HS-GC/MS analysis of the volatile profile of garlic.

  13. Determination of N-vinyl-2-pyrrolidone and N-methyl-2-pyrrolidone in drugs using polypyrrole-based headspace solid-phase microextraction and gas chromatography-nitrogen-phosphorous detection.

    PubMed

    Mehdinia, Ali; Ghassempour, Alireza; Rafati, Hasan; Heydari, Rouhollah

    2007-03-21

    A headspace solid-phase microextraction and gas chromatography-nitrogen-phosphorous detection (HS-SPME-GC-NPD) method using polypyrrole (PPy) fibers has been introduced to determine two derivatives of pyrrolidone; N-vinyl-2-pyrrolidone (NVP) and N-methyl-2-pyrrolidone (NMP). Two types of PPy fibers, prepared using organic and aqueous media, were compared in terms of extraction efficiency and thermal stability. It was found that PPy film prepared using organic medium (i.e. acetonitrile) had higher extraction efficiency and more thermal stability compared to the film prepared in aqueous medium. To enhance the sensitivity of HS-SPME, the effects of pH, ionic strength, extraction time, extraction temperature and the headspace volume on the extraction efficiency were optimized. Using the results of this research, high sensitivity and selectivity had been achieved due to the combination of the high extraction efficiency of PPy film prepared in organic medium and the high sensitivity and selectivity of nitrogen-phosphorous detection. Linear range of the analytes was found to be between 1.0 and 1000 microg L(-1) with regression coefficients (R(2)) of 0.998 and 0.997 for NVP and NMP, consequently. Limits of detection (LODs) were 0.074 and 0.081 microg L(-1) for NVP and NMP, respectively. Relative standard deviation (R.S.D.) for five replications of analyses was found to be less than 6.0%. In real samples the mean recoveries were 94.81% and 94.15% for NVP and NMP, respectively. The results demonstrated the suitability of the HS-SPME technique for analyzing NVP and NMP in two different pharmaceutical matrices. In addition, the method was used for simultaneous detection of NVP, 2-pyrrolidone (2-Pyr), gamma-butyrolactone (GBL) and ethanolamine (EA) compounds.

  14. [Establishment of Automation System for Detection of Alcohol in Blood].

    PubMed

    Tian, L L; Shen, Lei; Xue, J F; Liu, M M; Liang, L J

    2017-02-01

    To establish an automation system for detection of alcohol content in blood. The determination was performed by automated workstation of extraction-headspace gas chromatography (HS-GC). The blood collection with negative pressure, sealing time of headspace bottle and sample needle were checked and optimized in the abstraction of automation system. The automatic sampling was compared with the manual sampling. The quantitative data obtained by the automated workstation of extraction-HS-GC for alcohol was stable. The relative differences of two parallel samples were less than 5%. The automated extraction was superior to the manual extraction. A good linear relationship was obtained at the alcohol concentration range of 0.1-3.0 mg/mL ( r ≥0.999) with good repeatability. The method is simple and quick, with more standard experiment process and accurate experimental data. It eliminates the error from the experimenter and has good repeatability, which can be applied to the qualitative and quantitative detections of alcohol in blood. Copyright© by the Editorial Department of Journal of Forensic Medicine

  15. Efficient photocatalytic degradation of gaseous N,N-dimethylformamide in tannery waste gas using doubly open-ended Ag/TiO2 nanotube array membranes

    NASA Astrophysics Data System (ADS)

    Zhao, Yang; Ma, Lin; Chang, Wenkai; Huang, Zhiding; Feng, Xugen; Qi, Xiaoxia; Li, Zenghe

    2018-06-01

    Gaseous N,N-dimethylformamide (DMF), typical volatile organic compound exhausted from manufacturing factories, may damage the health of workers under long-term exposure even at low levels. The defined geometry, porous surface and highly ordered channels make the free-standing anodic TiO2 nanotube (TiNT) arrays particularly suitable for applications of practical air purification by flow-through photocatalysis. In the present work, crystallized doubly open-ended Ag/TiNT array membranes were designed and prepared by employing a lift-off process based on an anodization-annealing-anodization-etching sequence, followed by uniform Ag nanoparticles decoration. For the photocatalytic degradation of gaseous DMF at low concentration levels close to that found in realistic pollutant air, an analytical methodology for the monitoring and determination of degradation process was developed based on the coupling of headspace sampling with gas chromatography mass spectrometry (HS-GC-MS). The doubly open-ended Ag/TiNT arrays exhibited higher removal efficiency of gaseous DMF from air compared with conventional bottom-closed Ag/TiNT arrays and pure bottomless TiNT arrays. These results indicated that the photocatalytic properties of TiNT arrays were improved with the open-bottom morphology and the Ag nanoparticles decoration. Based on the analysis with GC-MS and high performance ion chromatography (HPIC), it was found that demethylation is the main pathway of DMF degradation in photocatalytic reactions. Furthermore, decontamination of actual polluted tannery waste gas collected in leather factory proved that the photocatalysis on doubly open-ended Ag/TiNT array membrane is an efficient way and a promising application to treat air contaminated by DMF despite the complexity of various volatile organic compounds.

  16. Analysis of Volatile Components of Cape Gooseberry (Physalis peruviana L.) Grown in Turkey by HS-SPME and GC-MS

    PubMed Central

    2014-01-01

    Volatile components in cape gooseberry fruit at ripe stage were collected using headspace-solid phase microextraction, and analyzed by gas chromatography-mass spectrometry. Three solid phase microextraction fiber coatings (DVB/CAR/PDMS, CAR/PDMS, and PDMS/DVB) were tested for evaluation of volatile compounds. DVB/CAR/PDMS fiber showed a strong extraction capacity for volatile compounds and produced the best result in case of total peak areas. A total of 133 volatile compounds were identified in fruit pulp; among them 1-hexanol (6.86%), eucalyptol (6.66%), ethyl butanoate (6.47%), ethyl octanoate (4.01%), ethyl decanoate (3.39%), 4-terpineol (3.27%), and 2-methyl-1-butanol (3.10%) were the major components in the sample extracts. PMID:24741358

  17. Analysis of volatile components of cape gooseberry (Physalis peruviana L.) grown in Turkey by HS-SPME and GC-MS.

    PubMed

    Yilmaztekin, Murat

    2014-01-01

    Volatile components in cape gooseberry fruit at ripe stage were collected using headspace-solid phase microextraction, and analyzed by gas chromatography-mass spectrometry. Three solid phase microextraction fiber coatings (DVB/CAR/PDMS, CAR/PDMS, and PDMS/DVB) were tested for evaluation of volatile compounds. DVB/CAR/PDMS fiber showed a strong extraction capacity for volatile compounds and produced the best result in case of total peak areas. A total of 133 volatile compounds were identified in fruit pulp; among them 1-hexanol (6.86%), eucalyptol (6.66%), ethyl butanoate (6.47%), ethyl octanoate (4.01%), ethyl decanoate (3.39%), 4-terpineol (3.27%), and 2-methyl-1-butanol (3.10%) were the major components in the sample extracts.

  18. Comprehensive Study of Volatile Compounds in Two Australian Rosé Wines: Aroma Extract Dilution Analysis (AEDA) of Extracts Prepared Using Solvent-Assisted Flavor Evaporation (SAFE) or Headspace Solid-Phase Extraction (HS-SPE).

    PubMed

    Wang, Jiaming; Gambetta, Joanna M; Jeffery, David W

    2016-05-18

    Two rosé wines, representing a tropical and a fruity/floral style, were chosen from a previous study for further exploration by aroma extract dilution analysis (AEDA) and quantitative analysis. Volatiles were extracted using either liquid-liquid extraction (LLE) followed by solvent-assisted flavor evaporation (SAFE) or a recently developed dynamic headspace (HS) sampling method utilizing solid-phase extraction (SPE) cartridges. AEDA was conducted using gas chromatography-mass spectrometry/olfactometry (GC-MS/O) and a total of 51 aroma compounds with a flavor dilution (FD) factor ≥3 were detected. Quantitative analysis of 92 volatiles was undertaken in both wines for calculation of odor activity values. The fruity and floral wine style was mostly driven by 2-phenylethanol, β-damascenone, and a range of esters, whereas 3-SHA and several volatile acids were seen as essential for the tropical style. When extraction methods were compared, HS-SPE was as efficient as SAFE for extracting most esters and higher alcohols, which were associated with fruity and floral characters, but it was difficult to capture volatiles with greater polarity or higher boiling point that may still be important to perceived wine aroma.

  19. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    PubMed

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  20. Metabolomics by Gas Chromatography-Mass Spectrometry: the combination of targeted and untargeted profiling

    PubMed Central

    Fiehn, Oliver

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS)-based metabolomics is ideal for identifying and quantitating small molecular metabolites (<650 daltons), including small acids, alcohols, hydroxyl acids, amino acids, sugars, fatty acids, sterols, catecholamines, drugs, and toxins, often using chemical derivatization to make these compounds volatile enough for gas chromatography. This unit shows that on GC-MS- based metabolomics easily allows integrating targeted assays for absolute quantification of specific metabolites with untargeted metabolomics to discover novel compounds. Complemented by database annotations using large spectral libraries and validated, standardized standard operating procedures, GC-MS can identify and semi-quantify over 200 compounds per study in human body fluids (e.g., plasma, urine or stool) samples. Deconvolution software enables detection of more than 300 additional unidentified signals that can be annotated through accurate mass instruments with appropriate data processing workflows, similar to liquid chromatography-MS untargeted profiling (LC-MS). Hence, GC-MS is a mature technology that not only uses classic detectors (‘quadrupole’) but also target mass spectrometers (‘triple quadrupole’) and accurate mass instruments (‘quadrupole-time of flight’). This unit covers the following aspects of GC-MS-based metabolomics: (i) sample preparation from mammalian samples, (ii) acquisition of data, (iii) quality control, and (iv) data processing. PMID:27038389

  1. Comprehensive two-dimensional gas chromatography with flame ionization and time-of-flight mass spectrometry detection: qualitative and quantitative analysis of West Australian sandalwood oil.

    PubMed

    Shellie, Robert; Marriott, Philip; Morrison, Paul

    2004-09-01

    The use of gas chromatography (GC)-mass spectrometry (MS), GC-time-of-flight MS (TOFMS), comprehensive two-dimensional GC (GCxGC)-flame ionization detection (FID), and GCxGC-TOFMS is discussed for the characterization of the eight important representative components, including Z-alpha-santalol, epi-alpha-bisabolol, Z-alpha-trans-bergamotol, epi-beta-santalol, Z-beta-santalol, E,E-farnesol, Z-nuciferol, and Z-lanceol, in the oil of west Australian sandalwood (Santalum spicatum). Single-column GC-MS lacks the resolving power to separate all of the listed components as pure peaks and allow precise analytical measurement of individual component abundances. With enhanced peak resolution capabilities in GCxGC, these components are sufficiently well resolved to be quantitated using flame ionization detection, following initial characterization of components by using GCxGC-TOFMS.

  2. Development of an Alternative Mixed Odor Delivery Device (MODD) for Canine Training

    DTIC Science & Technology

    2017-05-10

    solid phase microextraction (SPME) and analysis by gas chromatography / mass spectrometry (GC/MS). Like the computational modeling, the laboratory...outlet was extracted by solid phase microextraction (SPME) and analyzed by gas chromatography with mass spectrometry (GC/MS). A polydimethylsiloxane...Menning and H. Ostmark, "Detection of liquid and homemade explosives: What do we need to know about their properties?," in Detection of Liquid

  3. Carbohydrate profiling of bacteria by gas chromatography-mass spectrometry and their trace detection in complex matrices by gas chromatography-tandem mass spectrometry.

    PubMed

    Fox, A

    1999-05-28

    Bacterial cellular polysaccharides are composed of a variety of sugar monomers. These sugars serve as chemical markers to identify specific species or genera or to determine their physiological status. Some of these markers can also be used for trace detection of bacteria or their constituents in complex clinical or environmental matrices. Analyses are performed, in our hands, employing hydrolysis followed by the alditol acetate derivatization procedure. Substantial improvements have been made to sample preparation including simplification and computer-controlled automation. For characterization of whole cell bacterial hydrolysates, sugars are analyzed by gas chromatography-mass spectrometry (GC-MS). Simple chromatograms are generated using selected ion monitoring (SIM). Using total ion GC-MS, sugars can be readily identified. In more complex clinical and environmental samples, markers for bacteria are present at sufficiently low concentrations that more advanced instrumentation, gas chromatography-tandem mass spectrometry (GC-MS-MS), is preferred for optimal analysis. Using multiple reaction monitoring, MS-MS is used (replacing more conventional SIM) to ignore extraneous chromatographic peaks. Triple quadrupole and ion trap GC-MS-MS instruments have both been used successfully. Absolute chemical identification of sugar markers at trace levels is achieved, using MS-MS, by the product spectrum.

  4. Differentiating organically and conventionally grown oregano using ultraperformance liquid chromatography mass spectrometry (UPLC-MS), headspace gas chromatography with flame ionization detection (headspace-GC-FID), and flow injection mass spectrum (FIMS) fingerprints combined with multivariate data analysis.

    PubMed

    Gao, Boyan; Qin, Fang; Ding, Tingting; Chen, Yineng; Lu, Weiying; Yu, Liangli Lucy

    2014-08-13

    Ultraperformance liquid chromatography mass spectrometry (UPLC-MS), flow injection mass spectrometry (FIMS), and headspace gas chromatography (headspace-GC) combined with multivariate data analysis techniques were examined and compared in differentiating organically grown oregano from that grown conventionally. It is the first time that headspace-GC fingerprinting technology is reported in differentiating organically and conventionally grown spice samples. The results also indicated that UPLC-MS, FIMS, and headspace-GC-FID fingerprints with OPLS-DA were able to effectively distinguish oreganos under different growing conditions, whereas with PCA, only FIMS fingerprint could differentiate the organically and conventionally grown oregano samples. UPLC fingerprinting provided detailed information about the chemical composition of oregano with a longer analysis time, whereas FIMS finished a sample analysis within 1 min. On the other hand, headspace GC-FID fingerprinting required no sample pretreatment, suggesting its potential as a high-throughput method in distinguishing organically and conventionally grown oregano samples. In addition, chemical components in oregano were identified by their molecular weight using QTOF-MS and headspace-GC-MS.

  5. Application of acetone acetals as water scavengers and derivatization agents prior to the gas chromatographic analysis of polar residual solvents in aqueous samples.

    PubMed

    van Boxtel, Niels; Wolfs, Kris; Van Schepdael, Ann; Adams, Erwin

    2015-12-18

    The sensitivity of gas chromatography (GC) combined with the full evaporation technique (FET) for the analysis of aqueous samples is limited due to the maximum tolerable sample volume in a headspace vial. Using an acetone acetal as water scavenger prior to FET-GC analysis proved to be a useful and versatile tool for the analysis of high boiling analytes in aqueous samples. 2,2-Dimethoxypropane (DMP) was used in this case resulting in methanol and acetone as reaction products with water. These solvents are relatively volatile and were easily removed by evaporation enabling sample enrichment leading to 10-fold improvement in sensitivity compared to the standard 10μL FET sample volumes for a selection of typical high boiling polar residual solvents in water. This could be improved even further if more sample is used. The method was applied for the determination of residual NMP in an aqueous solution of a cefotaxime analogue and proved to be considerably better than conventional static headspace (sHS) and the standard FET approach. The methodology was also applied to determine trace amounts of ethylene glycol (EG) in aqueous samples like contact lens fluids, where scavenging of the water would avoid laborious extraction prior to derivatization. During this experiment it was revealed that DMP reacts quantitatively with EG to form 2,2-dimethyl-1,3-dioxolane (2,2-DD) under the proposed reaction conditions. The relatively high volatility (bp 93°C) of 2,2-DD makes it possible to perform analysis of EG using the sHS methodology making additional derivatization reactions superfluous. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Using comprehensive two-dimensional gas chromatography to explore the geochemistry of the Santa Barbara oil seeps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, Christopher; Nelson, Robert

    The development of comprehensive two-dimensional gas chromatography (GC x GC) has expanded the analytical window for studying complex mixtures like oil. Compared to traditional gas chromatography, this technology separates and resolves at least an order of magnitude more compounds, has a much larger signal to noise ratio, and sorts compounds based on their chemical class; hence, providing highly refined inventories of petroleum hydrocarbons in geochemical samples that was previously unattainable. In addition to the increased resolution afforded by GC x GC, the resulting chromatograms have been used to estimate the liquid vapor pressures, aqueous solubilities, octanol-water partition coefficients, and vaporizationmore » enthalpies of petroleum hydrocarbons. With these relationships, powerful and incisive analyses of phase-transfer processes affecting petroleum hydrocarbon mixtures in the environment are available. For example, GC x GC retention data has been used to quantitatively deconvolve the effects of phase transfer processes such as water washing and evaporation. In short, the positive attributes of GC x GC-analysis have led to a methodology that has revolutionized the analysis of petroleum hydrocarbons. Overall, this research has opened numerous fields of study on the biogeochemical "genetics" (referred to as petroleomics) of petroleum samples in both subsurface and surface environments. Furthermore, these new findings have already been applied to the behavior of oil at other seeps as well, for petroleum exploration and oil spill studies.« less

  7. Detailed study of polystyrene solubility using pyrolysis-gas chromatography-mass spectrometry and combination with size-exclusion chromatography.

    PubMed

    Chojnacka, Aleksandra; Janssen, Hans-Gerd; Schoenmakers, Peter

    2014-01-01

    Measuring polymer solubility accurately and precisely is challenging. This is especially true at unfavourable solvent compositions, when only very small amounts of polymer dissolve. In this paper, pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) is demonstrated to be much more informative and sensitive than conventional methods, such as ultraviolet spectroscopy. By using a programmed-temperature-vapourisation injector as the pyrolysis chamber, we demonstrate that Py-GC-MS can cover up to five orders of magnitude in dissolved polymer concentrations. For polystyrene, a detection limit of 1 ng mL(-1) is attained. Dissolution in poor solvents is demonstrated to be discriminating in terms of the analyte molecular weight. Py-GC-MS additionally can yield information on polymer composition (e.g. in case of copolymers). In combination with size-exclusion chromatography, Py-GC-MS allows us to estimate the molecular weight distributions of minute amounts of a dissolved polymer and variations therein as a function of time.

  8. Comprehensive two-dimensional gas chromatography for the analysis of Fischer-Tropsch oil products.

    PubMed

    van der Westhuizen, Rina; Crous, Renier; de Villiers, André; Sandra, Pat

    2010-12-24

    The Fischer-Tropsch (FT) process involves a series of catalysed reactions of carbon monoxide and hydrogen, originating from coal, natural gas or biomass, leading to a variety of synthetic chemicals and fuels. The benefits of comprehensive two-dimensional gas chromatography (GC×GC) compared to one-dimensional GC (1D-GC) for the detailed investigation of the oil products of low and high temperature FT processes are presented. GC×GC provides more accurate quantitative data to construct Anderson-Schultz-Flory (ASF) selectivity models that correlate the FT product distribution with reaction variables. On the other hand, the high peak capacity and sensitivity of GC×GC allow the detailed study of components present at trace level. Analyses of the aromatic and oxygenated fractions of a high temperature FT (HT-FT) process are presented. GC×GC data have been used to optimise or tune the HT-FT process by using a lab-scale micro-FT-reactor. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Formation of volatile compounds during heating of spice paprika (Capsicum annuum) powder.

    PubMed

    Cremer, D R; Eichner, K

    2000-06-01

    Spice paprika (red pepper; Capsicum annuum) is the most cultivated spice worldwide and is used mainly for its color and pungency. However, current research is also focusing on the flavor as an important parameter. This paper deals with the kinetics of the formation of those volatiles that indicate a decrease in spice paprika quality due to Maillard reaction, hydrolytic reactions, and oxidative degradation reactions of lipids such as fatty acids and carotenoids. Spice paprika volatiles were quantitatively analyzed by means of headspace gas chromatography (HS-GC) and solid-phase microextraction (SPME) followed by gas chromatography-mass spectrometry (GC-MS). The kinetics of their formation were investigated, and the respective activation energies determined. Strecker aldehyde, acetone, and methanol formation followed a pseudo-zero-order reaction kinetic, and formation of dimethyl sulfide (DMS) was characterized by a first-order kinetic. The activation energies determined were between 86.3 and 101.8 for the Strecker aldehydes acetaldehyde (AA), 2-methylpropanal (2-MP), 3-methylbutanal (3-MB), and 2-methylbutanal (2-MB), 130.7 for acetone, 114.2 for methanol, and 109.7 kJ/mol for DMS. The amounts of Strecker aldehydes formed were correlated to the concentrations of the corresponding free amino acids present in the samples. The formation of hexanal and 6-methyl-5-hepten-2-one in Capsicum annuum during processing was confirmed, and the formation of beta-ionone was probably described for the first time. During heating, the concentration of hexanal increased rapidly. The formation of 6-methyl-5-hepten-2-one confirms that Capsicum annuum fruits contain lycopene.

  10. Photodegradation of crude oil: liquid injection and headspace solid-phase microextraction for crude oil analysis by gas chromatography with mass spectrometer detector.

    PubMed

    D'Auria, Maurizio; Racioppi, Rocco; Velluzzi, Vincenzina

    2008-04-01

    The fate of crude oil under irradiation is studied. After UV irradiation, the fraction present in the highest percentage shifts from the C8-C9 fractions to C13, using gas chromatography-mass spectrometry (GC-MS) analysis in solution. An increase of the relative amount of the C13-C25 fraction is observed, while a decrease in the relative amount of the C7-C12 fractions is present. In headspace solid-phase microextraction (HS-SPME) analysis, the C8-C10 fractions represent 53% of all the compounds detected. A decrease in the relative amount of the C8-C10 fractions is observed, while C11-C15 fractions increase. The irradiation of crude oil with a solar simulator gives a mixture the analysis of which using GC-MS in solution furnishes the same type of results: the relative amounts of linear alkanes and aromatic compounds increase, while a sharp decrease in the relative amounts of branched and cyclic alkanes is observed. In the SPME analysis, a decreased relative amount of branched alkanes and alkenes, and an increase in the relative amounts of cyclic alkanes and aromatic compounds are observed. Analysis of the distribution of the compounds in all the types of compound shows that a dynamic equilibrium between different compounds and different types of compounds is present. To confirm the presence of a dynamic equilibrium, the irradiation of methylcyclohexane in the presence of 2-methylnaphthalene shows the presence in the reaction mixture of a small amount of tetradecane.

  11. Analysis of bacterial fatty acids by flow modulated comprehensive two-dimensional gas chromatography with parallel flame ionization detector/mass spectrometry.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Rumpel, Klaus; Xu, Guowang; De Vos, Paul; Sandra, Pat

    2010-06-25

    Comprehensive two-dimensional gas chromatography (GCxGC) offers an interesting tool for profiling bacterial fatty acids. Flow modulated GCxGC using a commercially available system was evaluated, different parameters such as column flows and modulation time were optimized. The method was tested on bacterial fatty acid methyl esters (BAMEs) from Stenotrophomonas maltophilia LMG 958T by using parallel flame ionization detector (FID)/mass spectrometry (MS). The results are compared to data obtained using a thermal modulated GCxGC system. The data show that flow modulated GCxGC-FID/MS method can be applied in a routine environment and offers interesting perspectives for chemotaxonomy of bacteria.

  12. Determination of volatile organic hydrocarbons in water samples by solid-phase dynamic extraction.

    PubMed

    Jochmann, Maik A; Yuan, Xue; Schmidt, Torsten C

    2007-03-01

    In the present study a headspace solid-phase dynamic extraction method coupled to gas chromatography-mass spectrometry (HS-SPDE-GC/MS) for the trace determination of volatile halogenated hydrocarbons and benzene from groundwater samples was developed and evaluated. As target compounds, benzene as well as 11 chlorinated and brominated hydrocarbons (vinyl chloride, dichloromethane, cis-1,2-dichloroethylene, trans-1,2-dichloroethylene, carbon tetrachloride, chloroform, trichloroethylene, tetrachloroethylene, bromoform) of environmental and toxicological concern were included in this study. The analytes were extracted using a SPDE needle device, coated with a poly(dimethylsiloxane) with 10% embedded activated carbon phase (50-microm film thickness and 56-mm film length) and were analyzed by GC/MS in full-scan mode. Parameters that affect the extraction yield such as extraction and desorption temperature, salting-out, extraction and desorption flow rate, extraction volume and desorption volume, the number of extraction cycles, and the pre-desorption time have been evaluated and optimized. The linearity of the HS-SPDE-GC/MS method was established over several orders of magnitude. Method detection limits (MDLs) for the compounds investigated ranged between 12 ng/L for cis-dichloroethylene and trans-dichloroethylene and 870 ng/L for vinyl chloride. The method was thoroughly validated, and the precision at two concentration levels (0.1 mg/L and a concentration 5 times above the MDL) was between 3.1 and 16% for the analytes investigated. SPDE provides high sensitivity, short sample preparation and extraction times and a high sample throughput because of full automation. Finally, the applicability to real environmental samples is shown exemplarily for various groundwater samples from a former waste-oil recycling facility. Groundwater from the site showed a complex contamination with chlorinated volatile organic compounds and aromatic hydrocarbons.

  13. Installation Restoration Program. Phase II. Confirmation/Quantification. Stage 1 for Carswell AFB, Texas. Volume 3. Appendices B-L.

    DTIC Science & Technology

    1986-10-01

    investigate the environ- mental feasibility of disposing of flue gas desulfurization (FGD) wastes, ash ’’p and sludge, from a mine mouth power plant by...Department of Defense o EMP - Electromagnetic Profiling o EPA - Environmental Protection Agency o GC - Gas Chromatography o GC-MS - Gas Chromatography-Mass...IN ITEM NO.) ADDITION 01 DELETION CODES: 0 -INTERMEDIATE CIRR: CONTROLLED ITEM RPT ROMT AFSC oRM 705 PREVOIJ EOTO’ , RE U C-4 4rsc-Aad.r IF ,,d 0,P E

  14. Gas chromatography: Possible application of advanced instrumentation developed for solar system exploration to space station cabin atmospheres

    NASA Technical Reports Server (NTRS)

    Carle, G. C.

    1985-01-01

    Gas chromatography (GC) technology was developed for flight experiments in solar system exploration. The GC is a powerful analytical technique with simple devices separating individual components from complex mixtures to make very sensitive quantitative and qualitative measurements. It monitors samples containing mixtures of fixed gases and volatile organic molecules. The GC was used on the Viking mission in support of life detection experiments and on the Pioneer Venus Large Probe to determine the composition of the venusian atmosphere. A flight GC is under development to study the progress and extent of STS astronaut denitrogenation prior to extravehicular activity. Advanced flight GC concepts and systems for future solar system exploration are also studied. Studies include miniature ionization detectors and associated control systems capable of detecting from ppb up to 100% concentration levels. Further miniaturization is investigated using photolithography and controlled chemical etching in silicon wafers. Novel concepts such as ion mobility drift spectroscopy and multiplex gas chromatography are also developed for future flight experiments. These powerful analytical concepts and associated hardware are ideal for the monitoring of cabin atmospheres containing potentially dangerous volatile compounds.

  15. Multidimensional analysis of cannabis volatile constituents: identification of 5,5-dimethyl-1-vinylbicyclo[2.1.1]hexane as a volatile marker of hashish, the resin of Cannabis sativa L.

    PubMed

    Marchini, Marie; Charvoz, Céline; Dujourdy, Laurence; Baldovini, Nicolas; Filippi, Jean-Jacques

    2014-11-28

    The volatile constituents of drug samples derived from Cannabis sativa L. were investigated by means of headspace solid phase microextraction (HS-SPME) and gas chromatography techniques (GC-MS, GC×GC-MS). Samples of cannabis herb and hashish showed clear differences in their volatile chemical profiles, mostly resulting from photo-oxidation processes occurring during the transformation of fresh cannabis herb into hashish. Most unexpectedly, we could demonstrate hashish samples as containing remarkable amounts of a rare and unusual monoterpene - 5,5-dimethyl-1-vinylbicyclo[2.1.1]hexane - among the volatile compounds detected in their headspaces. We gave evidence for the formation of this compound from the light induced rearrangement of β-myrcene during the manufacture of hashish. In view of its high abundance among volatile constituents of cannabis resin and its scarce occurrence in other natural volatile extracts, we propose to rename this specific monoterpene hashishene. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Headspace, volatile and semi-volatile organic compounds diversity and radical scavenging activity of ultrasonic solvent extracts from Amorpha fruticosa honey samples.

    PubMed

    Jerković, Igor; Marijanović, Zvonimir; Kezić, Janja; Gugić, Mirko

    2009-07-27

    Volatile organic compounds of Amorpha fruticosa honey samples were isolated by headspace solid-phase microextraction (HS-SPME) and ultrasonic solvent extraction (USE), followed by gas chromatography and mass spectrometry analyses (GC, GC-MS), in order to obtain complementary data for overall characterization of the honey aroma. The headspace of the honey was dominated by 2-phenylethanol (38.3-58.4%), while other major compounds were trans- and cis-linalool oxides, benzaldehyde and benzyl alcohol. 2-Phenylethanol (10.5-16.8%) and methyl syringate (5.8-8.2%) were the major compounds of ultrasonic solvent extracts, with an array of small percentages of linalool, benzene and benzoic acid derivatives, aliphatic hydrocarbons and alcohols, furan derivatives and others. The scavenging ability of the series of concentrations of the honey ultrasonic solvent extracts and the corresponding honey samples was tested by a DPPH (1,1-diphenyl-2-picrylhydrazyl) assay. Approximately 25 times lower concentration ranges (up to 2 g/L) of the extracts exhibited significantly higher free radical scavenging potential with respect to the honey samples.

  17. Analysis of 62 synthetic cannabinoids by gas chromatography-mass spectrometry with photoionization.

    PubMed

    Akutsu, Mamoru; Sugie, Ken-Ichi; Saito, Koichi

    2017-01-01

    Gas chromatography-mass spectrometry (GC-MS) in electron ionization (EI) mode is one of the most commonly used techniques for analysis of synthetic cannabinoids, because the GC-EI-MS spectra contain characteristic fragment ions for identification of a compound; however, the information on its molecular ions is frequently lacking. To obtain such molecular ion information, GC-MS in chemical ionization (CI) mode is frequently used. However, GC-CI-MS requires a relatively tedious process using reagent gas such as methane or isobutane. In this study, we show that GC-MS in photoionization (PI) mode provided molecular ions in all spectra of 62 synthetic cannabinoids, and 35 of the 62 compounds showed only the molecular radical cations. Except for the 35 compounds, the PI spectra showed very simple patterns with the molecular peak plus only a few fragment peak(s). An advantage is that the ion source for GC-PI-MS can easily be used for GC-EI-MS as well. Therefore, GC-EI/PI-MS will be a useful tool for the identification of synthetic cannabinoids contained in a dubious product. To the best of our knowledge, this is the first report to use GC-PI-MS for analysis of synthetic cannabinoids.

  18. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF PESTICIDE SAMPLES BY GC/MS (BCO-L-15.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography/mass spectrometry (GC/MS) of pesticides in a variety of matrices, including air, house dust, soil, and handwipes. This analysis involves automated gas GC/MS analysis us...

  19. Quantitative Determination of Perfluorochemicals and Fluorotelomer Alcohols in Plants from Biosolid-Amended Fields using LC/MS/MS and GC/MS

    EPA Science Inventory

    Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...

  20. The application of headspace gas chromatography coupled to tandem quadrupole mass spectrometry for the analysis of furan in baby food samples.

    PubMed

    Pugajeva, Iveta; Rozentale, Irina; Viksna, Arturs; Bartkiene, Elena; Bartkevics, Vadims

    2016-12-01

    Selective methodology employing a tandem quadrupole mass spectrometer coupled to a gas chromatograph with headspace autosampler (HS-GC-MS/MS) was elaborated in this study. Application of the elaborated procedure resulted in a limit of detection of 0.021μgkg(-1) and a limit of quantification of 0.071μgkg(-1). The mean recoveries during in-house validation ranged from 89% to 109%, and coefficients of variation for repeatability ranged from 4% to 11%. The proposed analytical method was applied for monitoring the furan content of 30 commercial baby food samples available on the Latvian retail market. The level of furan found in these samples varied from 0.45 to 81.9μgkg(-1), indicating that infants whose sole diet comprises baby food sold in jars and cans are exposed constantly to furan. Samples containing vegetables and meat had higher levels of furan than those containing only fruits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. ENVIRONMENTAL APPLICATION OF GAS CHROMATOGRAPHY/ATOMIC EMISSION DETECTION

    EPA Science Inventory

    A gas chromatography/atomic emission detector (GC/AED) system has been evaluated for its applicability to environmental analysis. Detection limits, elemental response factors, and regression analysis data were determined for 58 semivolatile environmental contaminants. Detection l...

  2. Picogram determination of N-nitrosodimethylamine in water.

    PubMed

    Hu, Ruikang; Zhang, Lifeng; Yang, Zhaoguang

    2008-01-01

    N-nitrosodimethylamine (NDMA) persistence within surface waters is a major concern for downstream communities exploiting these waters as drinking water supplies. The objective of this study is to develop a novel and efficient analytical method for NDMA via different technologies: pulsed splitless gas chromatography-nitrogen phosphorus detector (GC-NPD), large volume injection (LVI) gas chromatography-mass spectrometry (GC/MS) via programmable temperature vaporizer (PTV) inlet or PTV-gas chromatography-triple quadruple mass spectrometry (GC-MS/MS) and continuous liquid-liquid extraction. It was found that the sensitivity required for NDMA analysis by GC-NPD can only be achieved when the NPD bead is extremely clean. LVI via PTV can greatly improve GC-MS system sensitivity for analyzing NDMA. With the help of DB-624 (25 m x 200 microm x 1.12 microm) connected with DB-5MS (30 m x 250 microm x 0.25 microm) in series, PTV-GC/MS could overcome the matrix interference for the trace analysis of NDMA. Variable instrument conditions were studied in detail, with the optimized process being validated via precision and accuracy studies. PTV- triple quadruple GC-MS/MS system could efficiently remove the interference on a single DB-5MS (30 m x 250 microm x 0.25 microm) column with good sensitivity and selectivity. The developed methods have been successfully applied to test NDMA in different types of water samples with satisfactory results. (c) IWA Publishing 2008.

  3. Environmental assessment of an enhanced-oil-recovery steam generator equipped with a low-NOx burner. Volume 2. Data supplement. Final report, January 1984-January 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castaldini, C.; Waterland, L.R.; Lips, H.I.

    1986-02-01

    The report is a compendium of detailed test sampling and analysis data obtained in field tests of an enhanced-oil-recovery steam generator (EOR steamer) equipped with a MHI PM low-NOx crude oil burner. Test data reported include equipment calibration records, steamer operating data, and complete flue-gas emission results. Flue-gas emission measurements included continuous monitoring for criteria pollutants; onsite gas chromatography (GC) for volatile hydrocarbons (Cl-C6); Methods 5/8 sampling for particulate and SO/sub 2/ and SO/sub 3/ emissions; source assessment sampling system (SASS) for total organics in two boiling-point ranges (100 to 300 C and greater than or equal to 300 C),more » organic compound category information using infrared spectrometry (IR), and specific quantitation of the semivolatile organic priority pollutants using gas chromatography/mass spectrometry (GC/MS); Andersen impactor train measurements of emitted particle-size distribution; and N/sub 2/O emissions by gas chromatography/electron-capture detector (GC/ECD).« less

  4. A high-throughput headspace gas chromatographic technique for the determination of nitrite content in water samples.

    PubMed

    Zhang, Shu-Xin; Peng, Rong; Jiang, Ran; Chai, Xin-Sheng; Barnes, Donald G

    2018-02-23

    This paper reports on a high-throughput headspace gas chromatographic method (HS-GC) for the determination of nitrite content in water sample, based on GC measurement of cyclohexene produced from the reaction between nitrite and cyclamate in a closed vial. The method has a relative standard deviation of <3.5%; The differences between the results of the nitrite measurements obtained by this method and those of a reference method were less than 5.8% and the recoveries of the method were in the range of 94.8-102% (for a spiked nitrite content range from 0.002 to 0.03 mg/L). The limit of detection of the method was 0.46 μg L -1 . Due to an overlapping mode in the headspace auto-sampler system, the method can provide an automated and high-throughput nitrite analysis for the surface water samples. In short, the present HS-GC method is simple, accurate, and sensitive, and it is very suitable to be used in the batch sample testing. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Determination of vitamins D2 and D3 in selected food matrices by online high-performance liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS).

    PubMed

    Nestola, Marco; Thellmann, Andrea

    2015-01-01

    An online normal-phase liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS) method was developed for the determination of vitamins D2 and D3 in selected food matrices. Transfer of the sample from HPLC to GC was realized by large volume on-column injection; detection was performed with a time-of-flight mass spectrometer (TOF-MS). Typical GC problems in the determination of vitamin D such as sample degradation or sensitivity issues, previously reported in the literature, were not observed. Determination of total vitamin D content was done by quantitation of its pyro isomer based on an isotopically labelled internal standard (ISTD). Extracted ion traces of analyte and ISTD showed cross-contribution, but non-linearity of the calibration curve was not determined inside the chosen calibration range by selection of appropriate quantifier ions. Absolute limits of detection (LOD) and quantitation (LOQ) for vitamins D2 and D3 were calculated as approximately 50 and 150 pg, respectively. Repeatability with internal standard correction was below 2 %. Good agreement between quantitative results of an established high-performance liquid chromatography with UV detection (HPLC-UV) method and HPLC-GC-MS was found. Sterol-enriched margarine was subjected to HPLC-GC-MS and HPLC-MS/MS for comparison, because HPLC-UV showed strong matrix interferences. HPLC-GC-MS produced comparable results with less manual sample cleanup. In summary, online hyphenation of HPLC and GC allowed a minimization in manual sample preparation with an increase of sample throughput.

  6. Considerations on the determination of the limit of detection and the limit of quantification in one-dimensional and comprehensive two-dimensional gas chromatography.

    PubMed

    Krupčík, Ján; Májek, Pavel; Gorovenko, Roman; Blaško, Jaroslav; Kubinec, Robert; Sandra, Pat

    2015-05-29

    Methods based on the blank signal as proposed by IUPAC procedure and on the signal to noise ratio (S/N) as listed in the ISO-11843-1 norm for determination of the limit of detection (LOD) and quantitation (LOQ) in one-dimensional capillary gas chromatography (1D-GC) and comprehensive two-dimensional capillary gas chromatography (CG×GC) are described in detail and compared for both techniques. Flame ionization detection was applied and variables were the data acquisition frequency and, for CG×GC, also the modulation time. It has been stated that LOD and LOQ estimated according to IUPAC might be successfully used for 1D-GC-FID method. Moreover, LOD and LOQ decrease with decrease of data acquisition frequency (DAF). For GC×GC-FID, estimation of LOD by IUPAC gave poor reproducibility of results while for LOQ reproducibility was acceptable (within ±10% rel.). The LOD and LOQ determined by the S/N concept both for 1D-GC-FID and GC×GC-FID methods are ca. three times higher than those values estimated by the standard deviation of the blank. Since the distribution pattern of modulated peaks for any analyte separated by GC×GC is random and cannot be predicted, LOQ and LOD may vary within 30% for 3s modulation time. Concerning sensitivity, 1D-GC-FID at 2Hz and of GC×GC-FID at 50Hz shows a ca. 5 times enhancement of sensitivity in the modulated signal output. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Screening of salivary volatiles for putative breast cancer discrimination: an exploratory study involving geographically distant populations.

    PubMed

    Cavaco, Carina; Pereira, Jorge A M; Taunk, Khushman; Taware, Ravindra; Rapole, Srikanth; Nagarajaram, Hampapathalu; Câmara, José S

    2018-05-07

    Saliva is possibly the easiest biofluid to analyse and, despite its simple composition, contains relevant metabolic information. In this work, we explored the potential of the volatile composition of saliva samples as biosignatures for breast cancer (BC) non-invasive diagnosis. To achieve this, 106 saliva samples of BC patients and controls in two distinct geographic regions in Portugal and India were extracted and analysed using optimised headspace solid-phase microextraction gas chromatography mass spectrometry (HS-SPME/GC-MS, 2 mL acidified saliva containing 10% NaCl, stirred (800 rpm) for 45 min at 38 °C and using the CAR/PDMS SPME fibre) followed by multivariate statistical analysis (MVSA). Over 120 volatiles from distinct chemical classes, with significant variations among the groups, were identified. MVSA retrieved a limited number of volatiles, viz. 3-methyl-pentanoic acid, 4-methyl-pentanoic acid, phenol and p-tert-butyl-phenol (Portuguese samples) and acetic, propanoic, benzoic acids, 1,2-decanediol, 2-decanone, and decanal (Indian samples), statistically relevant for the discrimination of BC patients in the populations analysed. This work defines an experimental layout, HS-SPME/GC-MS followed by MVSA, suitable to characterise volatile fingerprints for saliva as putative biosignatures for BC non-invasive diagnosis. Here, it was applied to BC samples from geographically distant populations and good disease separation was obtained. Further studies using larger cohorts are therefore very pertinent to challenge and strengthen this proof-of-concept study. Graphical abstract ᅟ.

  8. [Rapid determination of volatile flavor compounds in soy sauce using head space solid-phase microextraction and gas chromatography-mass spectrometry].

    PubMed

    Yan, Liujun; Zhang, Yanfang; Tao, Wenyi; Wang, Liping; Wu, Shengfang

    2008-05-01

    A rapid and simple method was developed for the determination of volatile flavor compounds (VFCs) in soy sauce by head space solid-phase microextraction (HS-SPME) coupled to capillary gas chromatography-mass spectrometry (GC-MS). Five types of SPME fibers, including 85 microm PA, 100 microm PDMS, 75 microm CAR/PDMS, 65 microm PDMS/DVB, 50 microm DVB/CAR/PDMS were investigated. Three parameters for HS-SPME in terms of adsorption time, salt concentration, and extraction temperature were optimized. Adsorption time tested in this study were 20, 40 and 60 minutes; the salt concentrations were 180, 210, 250, 270 and 300 g/L; and extraction temperatures were 25, 35, 45, 55 and 65 degrees C. The concentrations of the compounds were calculated based on their relative peak areas to the internal standard of 2-octanol. An 85 microm PA fiber, adsorption time of 40 min, a temperature of 45 degrees C and NaCl concentration of 250 g/L were selected as th optimum conditions. This optimized method was applied to evaluate a real sample. As a result, 97 compounds in a soy sauce sample were isolated and identified successfully. The results showed that alcohols, carboxylic acids, esters and phenols were the major VFCs of soy sauce. The most important groups of volatile compounds in the soy sauce sample were ethanol, hexadecanoic acid, phenylethyl alcohol and 2,3-butanediol. In addition, some oxo-compounds and heterocyclic compounds were also found. The average relative standard deviation of the relative peak area was 12.1%, and the recoveries were 79.9% - 109.6%. The method is simple, fast and accurate with high reproducibility, high sensitivity and low cost.

  9. Chemical composition of the essential oil of Feronia elephantum Correa.

    PubMed

    Pande, Chitra; Tewari, Geeta; Singh, Charu; Singh, Shalini; Padalia, R C

    2010-11-01

    The essential oil composition of Feronia elephantum Correa (family: Rutaceae) was examined by capillary gas chromatography (GC) and gas chromatography-mass spectroscopy (GC-MS). The analysis revealed the presence of 24 constituents, of which 18 constituents were identified. Trans-anethole (57.73%) and methyl chavicol (37.48%) were the major compounds, while cis-anethole, p-anisaldehyde, (E)-jasmone, methyl eugenol, β-caryophyllene, linalool and (E)-methyl isoeugenol were also present as the minor constituents.

  10. Application of the experimental design of experiments (DoE) for the determination of organotin compounds in water samples using HS-SPME and GC-MS/MS.

    PubMed

    Coscollà, Clara; Navarro-Olivares, Santiago; Martí, Pedro; Yusà, Vicent

    2014-02-01

    When attempting to discover the important factors and then optimise a response by tuning these factors, experimental design (design of experiments, DoE) gives a powerful suite of statistical methodology. DoE identify significant factors and then optimise a response with respect to them in method development. In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography tandem mass spectrometry (GC-MS/MS) methodology for the simultaneous determination of six important organotin compounds namely monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), diphenyltin (DPhT), triphenyltin (TPhT) has been optimized using a statistical design of experiments (DOE). The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC-MS/MS analysis. The main experimental parameters influencing the extraction efficiency selected for optimization were pre-incubation time, incubation temperature, agitator speed, extraction time, desorption temperature, buffer (pH, concentration and volume), headspace volume, sample salinity, preparation of standards, ultrasonic time and desorption time in the injector. The main factors (excitation voltage, excitation time, ion source temperature, isolation time and electron energy) affecting the GC-IT-MS/MS response were also optimized using the same statistical design of experiments. The proposed method presented good linearity (coefficient of determination R(2)>0.99) and repeatibilty (1-25%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked surface and marine waters was higher than 70% for all compounds studied. Finally, the optimized methodology was applied to real aqueous samples enabled the simultaneous determination of all compounds under study in surface and marine water samples obtained from Valencia region (Spain). © 2013 Elsevier B.V. All rights reserved.

  11. Investigation of Mg(OH)2 nanoparticles as an antibacterial agent

    NASA Astrophysics Data System (ADS)

    Dong, Chunxu; Cairney, John; Sun, Qunhui; Maddan, Orville Lee; He, Gaohong; Deng, Yulin

    2010-08-01

    Our experimental results of using Mg(OH)2 nanoparticles as an antibacterial agent are reported in this study. The antibacterial behavior of Mg(OH)2 nanoparticles in liquid culture and in paper sheets was investigated. The colony forming units (CFU) counting and the headspace gas chromatography (HS-GC) measurement were used to determine the cell viability. Results indicate that Mg(OH)2 nanoparticles are effective antibacterial agent against Escherichia coli ( E. coli) and Burkholderia phytofirmans, and the OH- and Mg2+ ions in Mg(OH)2 water suspension were found not to be the reason for killing the bacteria. Mg(OH)2 nanoparticles could be added directly to wood pulp to make paper sheets, whose antibacterial efficiency increased with the increase of the nanoparticle amount. The possible mechanism of antibacterial effect of Mg(OH)2 nanoparticles is discussed.

  12. HS/GC-MS analyzed chemical composition of the aroma of fruiting bodies of two species of genus Lentinus (Higher Basidiomycetes).

    PubMed

    Mata, Gerardo; Valdez, Karina; Mendoza, Remedios; Trigos, Ángel

    2014-01-01

    The chemical composition of the aroma of fresh fruiting bodies of the cultivated mushroom Lentinus boryanus is described here and compared with medicinal shiitake mushroom L. edodes. Volatile compounds were analyzed through headspace sampling coupled with gas chromatography-mass spectrometry. The mushrooms under study were grown on different substrates based on barley straw, sugarcane bagasse, oak wood sawdust, and beech leaf litter. It was determined that L. boryanus as well as L. edodes contain an abundant amount of a volatile compound identified as 3-octanone with a sweet fruity aroma. On the other hand, only L. boryanus produced 3-octanol a characteristic aroma of cod liver oil. In total, 10 aromatic compounds were identified, some of which were obtained exclusively in one species or substrate.

  13. Preliminary Results on the Use of Leather Chrome Shavings for Air Passive Sampling

    PubMed Central

    Sanjuán-Herráez, D.; Chabaane, L.; Tahiri, S.; Pastor, A.; de la Guardia, M.

    2012-01-01

    A new passive sampler based on low-density polyethylene (LDPE) layflat tube filled with chrome shavings from tannery waste residues was evaluated to determine volatile organic compounds (VOCs) in indoor and outdoor areas. VOCs were directly determined by head space-gas chromatography-mass spectrometry (HS-GC-MS) without any pretreatment of the sampler and avoiding the use of solvents. Limit of detection values ranging from 20 to 75 ng sampler−1 and good repeatability values were obtained for VOCs under study with relative standard deviation values from 2.8 to 9.6% except for carbon disulfide for which it was 22.5%. The effect of the amount of chrome shavings per sampler was studied and results were compared with those obtained using empty LDPE tubes, to demonstrate the capacity of chrome shavings to adsorb VOCs. PMID:22900233

  14. Intercomparison of the measurements of oxalic acid in aerosols by gas chromatography and ion chromatography

    NASA Astrophysics Data System (ADS)

    Kawamura, Kimitaka; Barrie, Leonard A.; Toom-Sauntry, Desiree

    2010-12-01

    Oxalate, the anion of oxalic acid, is one of the most abundant measurable organic species in atmospheric aerosols. Traditionally, this bifunctional species has been measured by gas chromatography (GC) after derivatization to butyl ester and by ion chromatography (IC) without derivatization. However, there are few published comparisons of the two techniques. Here, we report the results of an intercomparison study for the measurement of oxalic acid in Arctic aerosols (<2.5 μm, n = 82) collected in 1992 using GC and IC. The concentrations of oxalic acid by GC ranged from 6.5-59.1 ng m -3 (av. 26.0 ng m -3, median 26.2 ng m -3) whereas those by IC ranged from 6.6-52.1 ng m -3 (av. 26.6 ng m -3, median 25.4 ng m -3). They showed a good correlation ( r = 0.84) with a slope of 0.96. Thus, observations of oxalate obtained by GC employing dibutyl esters are almost equal to those by IC. Because the accuracy of oxalic acid by GC method largely depends on the method used, it is important to strictly examine the recovery in each study.

  15. Comparison of traditional gas chromatography (GC), headspace GC, and the microbial identification library GC system for the identification of Clostridium difficile.

    PubMed Central

    Cundy, K V; Willard, K E; Valeri, L J; Shanholtzer, C J; Singh, J; Peterson, L R

    1991-01-01

    Three gas chromatography (GC) methods were compared for the identification of 52 clinical Clostridium difficile isolates, as well as 17 non-C. difficile Clostridium isolates. Headspace GC and Microbial Identification System (MIS) GC, an automated system which utilizes a software library developed at the Virginia Polytechnic Institute to identify organisms based on the fatty acids extracted from the bacterial cell wall, were compared against the reference method of traditional GC. Headspace GC and MIS were of approximately equivalent accuracy in identifying the 52 C. difficile isolates (52 of 52 versus 51 of 52, respectively). However, 7 of 52 organisms required repeated sample preparation before an identification was achieved by the MIS method. Both systems effectively differentiated C. difficile from non-C. difficile clostridia, although the MIS method correctly identified only 9 of 17. We conclude that the headspace GC system is an accurate method of C. difficile identification, which requires only one-fifth of the sample preparation time of MIS GC and one-half of the sample preparation time of traditional GC. PMID:2007632

  16. Chemical Composition of Latent Fingerprints by Gas Chromatography-Mass Spectrometry

    ERIC Educational Resources Information Center

    Hartzell-Baguley, Brittany; Hipp, Rachael E.; Morgan, Neal R.; Morgan, Stephen L.

    2007-01-01

    An experiment in which gas chromatography-mass spectrometry (GC-MS) is used for latent fingerprint extraction and analysis on glass beads or glass slides is conducted. The results determine that the fingerprint residues are gender dependent.

  17. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates.

    PubMed

    Moerdijk-Poortvliet, Tanja C W; Schierbeek, Henk; Houtekamer, Marco; van Engeland, Tom; Derrien, Delphine; Stal, Lucas J; Boschker, Henricus T S

    2015-07-15

    We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of δ(13)C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although LC/IRMS is expected to be more accurate and precise, no direct comparison has been reported. GC/IRMS with the aldonitrile penta-acetate (ANPA) derivatisation method was compared with LC/IRMS without derivatisation. A large number of glucose standards and a variety of natural samples were analysed for five neutral carbohydrates at natural abundance as well as at (13)C-enriched levels. Gas chromatography/chemical ionisation mass spectrometry (GC/CIMS) was applied to check for incomplete derivatisation of the carbohydrate, which would impair the accuracy of the GC/IRMS method. The LC/IRMS technique provided excellent precision (±0.08‰ and ±3.1‰ at natural abundance and enrichment levels, respectively) for the glucose standards and this technique proved to be superior to GC/IRMS (±0.62‰ and ±19.8‰ at natural abundance and enrichment levels, respectively). For GC/IRMS measurements the derivatisation correction and the conversion of carbohydrates into CO2 had a considerable effect on the measured δ(13)C values. However, we did not find any significant differences in the accuracy of the two techniques over the full range of natural δ(13)C abundances and (13)C-labelled glucose. The difference in the performance of GC/IRMS and LC/IRMS diminished when the δ(13)C values were measured in natural samples, because the chromatographic performance and background correction became critical factors, particularly for LC/IRMS. The derivatisation of carbohydrates for the GC/IRMS method was complete. Although both LC/IRMS and GC/IRMS are reliable techniques for compound-specific stable carbon isotope analysis of carbohydrates (provided that derivatisation is complete and the calibration requirements are met), LC/IRMS is the technique of choice. The reasons for this are the improved precision, simpler sample preparation, and straightforward isotopic calibration. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.

    1996-01-01

    A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

  19. 40 CFR 63.786 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... by Gas Chromatography (incorporation by reference—see § 63.14). In determining the sensitivity, the... Practice for Gas Chromatography [incorporation by reference—see § 63.14].) (c) A coating manufacturer or... mixture under analysis are not known. In such cases a single column gas chromatograph (GC) may not be...

  20. 40 CFR 63.786 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... by Gas Chromatography (incorporation by reference—see § 63.14). In determining the sensitivity, the... Practice for Gas Chromatography [incorporation by reference—see § 63.14].) (c) A coating manufacturer or... mixture under analysis are not known. In such cases a single column gas chromatograph (GC) may not be...

  1. 75 FR 14154 - Notice of Receipt of Several Pesticide Petitions Filed for Residues of Pesticide Chemicals in or...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-24

    ... for plant commodities) are both gas liquid chromatography (GLC) methods with electron capture... analytical methodology using liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) detection...-aminopropane]) using gas chromatography (GC) have been submitted to the EPA. In addition, a new validated...

  2. Lipids and Fatty Acids in Algae: Extraction, Fractionation into Lipid Classes, and Analysis by Gas Chromatography Coupled with Flame Ionization Detector (GC-FID).

    PubMed

    Guihéneuf, Freddy; Schmid, Matthias; Stengel, Dagmar B

    2015-01-01

    Despite the number of biochemical studies exploring algal lipids and fatty acid biosynthesis pathways and profiles, analytical methods used by phycologists for this purpose are often diverse and incompletely described. Potential confusion and potential variability of the results between studies can therefore occur due to change of protocols for lipid extraction and fractionation, as well as fatty acid methyl esters (FAME) preparation before gas chromatography (GC) analyses. Here, we describe a step-by-step procedure for the profiling of neutral and polar lipids using techniques such as solid-liquid extraction (SLE), thin-layer chromatography (TLC), and gas chromatography coupled with flame ionization detector (GC-FID). As an example, in this protocol chapter, analyses of neutral and polar lipids from the marine microalga Pavlova lutheri (an EPA/DHA-rich haptophyte) will be outlined to describe the distribution of fatty acid residues within its major lipid classes. This method has been proven to be a reliable technique to assess changes in lipid and fatty acid profiles in several other microalgal species and seaweeds.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Read, Douglas; Sillerud, Colin Halliday

    The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; andmore » the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.« less

  4. SPME-GC-MS analysis of commercial henna samples (Lawsonia inermis L.).

    PubMed

    Mengoni, Tamara; Peregrina, Dolores Vargas; Censi, Roberta; Cortese, Manuela; Ricciutelli, Massimo; Maggi, Filippo; Di Martino, Piera

    2016-01-01

    The aim of this work was to provide a characterisation of volatile constituents from different commercial batches of henna (Lawsonia inermis) leaves of different geographic origin. Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was used for the purpose. A total of 72 components were identified by GC-MS in the headspace of different henna samples which proved to differ considerably from each other, because they were characterised by different classes of components, mainly aliphatic compounds (9.0-64.7%), terpenoids (5.8-45.5%) and aromatics (7.9-45.2%), with alkanes (0.9-18.5%), aldehydes (2.1-18.8%) and carboxylic acids (3.1-29.3%), monoterpenes (3.4-30.0%) and sesquiterpenes (0.8-23.7%) and phenyl propanoids (0.6-43.1%), being the most abundant, respectively. Major representatives of these groups were n-hexadecane (0.5-4.7%), (2E)-hexenal (0.5-11.7%) and acetic acid (2.8-24.5%), limonene (0.8-14.7%), carvol (3.8-7.1%), geranyl acetone (1.4-7.9%) and (E)-caryophyllene (3.3-8.4%), and (E)-anethole (0.6-35.0%), respectively. We assume that factors such as the manufacturing process, the storage conditions and the different geographic origin of the samples may contribute to such variability.

  5. Aroma changes of black tea prepared from methyl jasmonate treated tea plants*

    PubMed Central

    Shi, Jiang; Wang, Li; Ma, Cheng-ying; Lv, Hai-peng; Chen, Zong-mao; Lin, Zhi

    2014-01-01

    Methyl jasmonate (MeJA) was widely applied in promoting food quality. Aroma is one of the key indicators in judging the quality of tea. This study examined the effect of exogenous MeJA treatment on tea aroma. The aroma components in black tea prepared from MeJA-treated fresh tea leaves were extracted using headspace solid-phase microextraction (HS-SPME) and were analyzed using gas chromatography-mass spectrometry (GC-MS) and GC-olfactometry (GC-O). Forty-five volatile compounds were identified. The results revealed that the MeJA-treated black tea had higher levels of terpene alcohols and hexenyl esters than the untreated tea. Moreover, several newly components, including copaene, cubenol, and indole, were induced by the MeJA treatment. The activities of polyphenol oxidase and β-glucosidase in fresh tea leaves changed after the MeJA treatment. Quantitative real-time polymerase chain reaction (qRT-PCR) analysis indicated that the gene expression levels of polyphenol oxidase and β-primeverosidase were upregulated by two and three folds, respectively, by the MeJA treatment (P<0.01); however, the gene expression of β-glucosidase was downregulated to a half level. In general, the aroma quality of the MeJA-treated black tea was clearly improved. PMID:24711352

  6. 75 FR 47036 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-04

    ... Spectrometry (CS-MS) Systems, High Performance Liquid Chromatography (HPLC) Systems, Gas Chromatography Mass...-portable CS-MS, HPLC, GC-MS, and, ICP-MS Laboratory Equipment under PSC 6640 (Laboratory Equipment and...-portable equipment, SBA is limiting the waiver to not-portable CS-MS Systems, HPLC Systems, GC-MS Systems...

  7. Compound-Specific Chlorine Isotope Analysis of Tetrachloromethane and Trichloromethane by Gas Chromatography-Isotope Ratio Mass Spectrometry vs Gas Chromatography-Quadrupole Mass Spectrometry: Method Development and Evaluation of Precision and Trueness.

    PubMed

    Heckel, Benjamin; Rodríguez-Fernández, Diana; Torrentó, Clara; Meyer, Armin; Palau, Jordi; Domènech, Cristina; Rosell, Mònica; Soler, Albert; Hunkeler, Daniel; Elsner, Martin

    2017-03-21

    Compound-specific chlorine isotope analysis of tetrachloromethane (CCl 4 ) and trichloromethane (CHCl 3 ) was explored by both, gas chromatography-isotope ratio mass spectrometry (GC-IRMS) and GC-quadrupole MS (GC-qMS), where GC-qMS was validated in an interlaboratory comparison between Munich and Neuchâtel with the same type of commercial GC-qMS instrument. GC-IRMS measurements analyzed CCl isotopologue ions, whereas GC-qMS analyzed the isotopologue ions CCl 3 , CCl 2 , CCl (of CCl 4 ) and CHCl 3 , CHCl 2 , CHCl (of CHCl 3 ), respectively. Lowest amount dependence (good linearity) was obtained (i) in H-containing fragment ions where interference of 35 Cl- to 37 Cl-containing ions was avoided; (ii) with tuning parameters favoring one predominant rather than multiple fragment ions in the mass spectra. Optimized GC-qMS parameters (dwell time 70 ms, 2 most abundant ions) resulted in standard deviations of 0.2‰ (CHCl 3 ) and 0.4‰ (CCl 4 ), which are only about twice as large as 0.1‰ and 0.2‰ for GC-IRMS. To compare also the trueness of both methods and laboratories, samples from CCl 4 and CHCl 3 degradation experiments were analyzed and calibrated against isotopically different reference standards for both CCl 4 and CHCl 3 (two of each). Excellent agreement confirms that true results can be obtained by both methods provided that a consistent set of isotopically characterized reference materials is used.

  8. Contaminant Mass Transfer During Boiling in Fractured Geologic Media

    DTIC Science & Technology

    2011-04-01

    on GC-ECD. Bromide was measured on a Dionex AS50 ion chromatography system equipped with a CD25 conductivity detector and a Dionex guard column...EDB Dibromethane EPICS Equilibrium Partitioning In Closed Systems FID Flame Ionized Detector GC Gas Chromatography IC Ion Chromatography ...International). Bromide was measured from filtered samples with a Dionex ion chromatograph (IC) with an AS11/AG11 column. The eluant for bromide

  9. Application of comprehensive multidimensional gas chromatography combined with time-of-flight mass spectrometry (GC x GC-TOFMS) for high resolution analysis of hop essential oil.

    PubMed

    Roberts, Mark T; Dufour, Jean-Pierre; Lewis, Alastair C

    2004-04-01

    The selection and quality of hops is a major determinant in beer flavour. Brewers acknowledge that distinctive characteristics of different hop varieties can be traced to the composition of their essential oils. The difficulty in characterising complex mixtures such as hop oil using 1-D chromatography is that many compounds co-elute. With the introduction of comprehensive multidimensional capillary gas chromatography (GC x GC), there is a tremendous improvement in the separation power or peak capacity. Recent work using GC x GC with flame ionisation detection has suggested that there may be over 1,000 compounds in hop oil. This work describes the use of GC x GC combined with TOFMS detection (Leco Pegasus 4D instrument) to analyse Target hop oil. The TOFMS spectral acquisition rate of 60 Hz provided sufficient spectra per peak (2-D peak base width of 0.1-0.2 s) for identification (119 components were identified with 45 previously unreported compounds). When analysing results, an advantage of GC x GC coupled to TOFMS is that 2-D chromatograms can be viewed for individual masses that are characteristic of particular functional groups. This allows the analyst to view the various homologous series of compounds although in certain cases coelution may still be present as shown by the esters with mass 75.

  10. Measurement of activity coefficients of mixtures by head-space gas chromatography: general procedure.

    PubMed

    Luis, Patricia; Wouters, Christine; Van der Bruggen, Bart; Sandler, Stanley I

    2013-08-09

    Head-space gas chromatography (HS-GC) is an applicable method to perform vapor-liquid equilibrium measurements and determine activity coefficients. However, the reproducibility of the data may be conditioned by the experimental procedure concerning to the automated pressure-balanced system. The study developed in this work shows that a minimum volume of liquid in the vial is necessary to ensure the reliability of the activity coefficients since it may become a parameter that influences the magnitude of the peak areas: the helium introduced during the pressurization step may produce significant variations of the results when too small volume of liquid is selected. The minimum volume required should thus be evaluated prior to obtain experimentally the concentration in the vapor phase and the activity coefficients. In this work, the mixture acetonitrile-toluene is taken as example, requiring a sample volume of more than 5mL (about more than 25% of the vial volume). The vapor-liquid equilibrium and activity coefficients of mixtures at different concentrations (0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 molar fraction) and four temperatures (35, 45, 55 and 70°C) have been determined. Relative standard deviations (RSD) lower than 5% have been obtained, indicating the good reproducibility of the method when a sample volume larger than 5mL is used. Finally, a general procedure to measure activity coefficients by means of pressure-balanced head-space gas chromatography is proposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Formation of dehydroalanine from mimosine and cysteine: artifacts in gas chromatography/mass spectrometry based metabolomics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Young-Mo; Metz, Thomas O.; Hu, Zeping

    2011-08-15

    Trimethylsilyation is a chemical derivatization procedure routinely applied in gas chromatography-mass spectrometry (GC-MS)-based metabolomics. In this report, through de novo structural elucidation and comparison with authentic standards, we demonstrate that mimosine can be completely converted into dehydroalanine and 3,4-dihydroxypyridine during the trimethylsilyating process. Similarly, dehydroalanine can be formed from derivatization of cysteine. This conversion is a potential interference in GC-MS-based global metabolomics, as well as in analysis of amino acids.

  12. Freeze drying for gas chromatography stationary phase deposition

    DOEpatents

    Sylwester, Alan P [Livermore, CA

    2007-01-02

    The present disclosure relates to methods for deposition of gas chromatography (GC) stationary phases into chromatography columns, for example gas chromatography columns. A chromatographic medium is dissolved or suspended in a solvent to form a composition. The composition may be inserted into a chromatographic column. Alternatively, portions of the chromatographic column may be exposed or filled with the composition. The composition is permitted to solidify, and at least a portion of the solvent is removed by vacuum sublimation.

  13. Gas chromatographic-mass spectrometric analysis of urinary volatile organic metabolites: Optimization of the HS-SPME procedure and sample storage conditions.

    PubMed

    Živković Semren, Tanja; Brčić Karačonji, Irena; Safner, Toni; Brajenović, Nataša; Tariba Lovaković, Blanka; Pizent, Alica

    2018-01-01

    Non-targeted metabolomics research of human volatile urinary metabolome can be used to identify potential biomarkers associated with the changes in metabolism related to various health disorders. To ensure reliable analysis of urinary volatile organic metabolites (VOMs) by gas chromatography-mass spectrometry (GC-MS), parameters affecting the headspace-solid phase microextraction (HS-SPME) procedure have been evaluated and optimized. The influence of incubation and extraction temperatures and times, coating fibre material and salt addition on SPME efficiency was investigated by multivariate optimization methods using reduced factorial and Doehlert matrix designs. The results showed optimum values for temperature to be 60°C, extraction time 50min, and incubation time 35min. The proposed conditions were applied to investigate urine samples' stability regarding different storage conditions and freeze-thaw processes. The sum of peak areas of urine samples stored at 4°C, -20°C, and -80°C up to six months showed a time dependent decrease over time although storage at -80°C resulted in a slight non-significant reduction comparing to the fresh sample. However, due to the volatile nature of the analysed compounds, more than two cycles of freezing/thawing of the sample stored for six months at -80°C should be avoided whenever possible. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Quantitative fingerprinting by headspace--two-dimensional comprehensive gas chromatography-mass spectrometry of solid matrices: some challenging aspects of the exhaustive assessment of food volatiles.

    PubMed

    Nicolotti, Luca; Cordero, Chiara; Cagliero, Cecilia; Liberto, Erica; Sgorbini, Barbara; Rubiolo, Patrizia; Bicchi, Carlo

    2013-10-10

    The study proposes an investigation strategy that simultaneously provides detailed profiling and quantitative fingerprinting of food volatiles, through a "comprehensive" analytical platform that includes sample preparation by Headspace Solid Phase Microextraction (HS-SPME), separation by two-dimensional comprehensive gas chromatography coupled with mass spectrometry detection (GC×GC-MS) and data processing using advanced fingerprinting approaches. Experiments were carried out on roasted hazelnuts and on Gianduja pastes (sugar, vegetable oil, hazelnuts, cocoa, nonfat dried milk, vanilla flavorings) and demonstrated that the information potential of each analysis can better be exploited if suitable quantitation methods are applied. Quantitation approaches through Multiple Headspace Extraction and Standard Addition were compared in terms of performance parameters (linearity, precision, accuracy, Limit of Detection and Limit of Quantitation) under headspace linearity conditions. The results on 19 key analytes, potent odorants, and technological markers, and more than 300 fingerprint components, were used for further processing to obtain information concerning the effect of the matrix on volatile release, and to produce an informative chemical blueprint for use in sensomics and flavoromics. The importance of quantitation approaches in headspace analysis of solid matrices of complex composition, and the advantages of MHE, are also critically discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Ripening-dependent metabolic changes in the volatiles of pineapple (Ananas comosus (L.) Merr.) fruit: II. Multivariate statistical profiling of pineapple aroma compounds based on comprehensive two-dimensional gas chromatography-mass spectrometry.

    PubMed

    Steingass, Christof Björn; Jutzi, Manfred; Müller, Jenny; Carle, Reinhold; Schmarr, Hans-Georg

    2015-03-01

    Ripening-dependent changes of pineapple volatiles were studied in a nontargeted profiling analysis. Volatiles were isolated via headspace solid phase microextraction and analyzed by comprehensive 2D gas chromatography and mass spectrometry (HS-SPME-GC×GC-qMS). Profile patterns presented in the contour plots were evaluated applying image processing techniques and subsequent multivariate statistical data analysis. Statistical methods comprised unsupervised hierarchical cluster analysis (HCA) and principal component analysis (PCA) to classify the samples. Supervised partial least squares discriminant analysis (PLS-DA) and partial least squares (PLS) regression were applied to discriminate different ripening stages and describe the development of volatiles during postharvest storage, respectively. Hereby, substantial chemical markers allowing for class separation were revealed. The workflow permitted the rapid distinction between premature green-ripe pineapples and postharvest-ripened sea-freighted fruits. Volatile profiles of fully ripe air-freighted pineapples were similar to those of green-ripe fruits postharvest ripened for 6 days after simulated sea freight export, after PCA with only two principal components. However, PCA considering also the third principal component allowed differentiation between air-freighted fruits and the four progressing postharvest maturity stages of sea-freighted pineapples.

  16. Investigation of the Storage Behavior of Shredded Lithium-Ion Batteries from Electric Vehicles for Recycling Purposes.

    PubMed

    Grützke, Martin; Krüger, Steffen; Kraft, Vadim; Vortmann, Britta; Rothermel, Sergej; Winter, Martin; Nowak, Sascha

    2015-10-26

    Shredding of the cells is often the first step in lithium-ion battery (LIB) recycling. Thus, LiNi1/3 Mn1/3 Co1/3 O2 (NMC)/graphite lithium-ion cells from a field-tested electric vehicle were shredded and transferred to tinplate or plastic storage containers. The formation of hazardous compounds within, and being released from, these containers was monitored over 20 months. The tinplate cans underwent fast corrosion as a result of either residual charge in the active battery material, which could not fully be discharged because of contact loss to the current collector, or redox reactions between the tinplate surface and metal parts of the shredded material. The headspace compositions of the containers were investigated at room temperature and 150 °C using headspace-gas chromatography-mass spectrometry (HS-GC-MS). Samples of the waste material were also collected using microwave-assisted extraction and the extracts were analyzed over a period of 20 months using ion chromatography-electrospray ionization-mass spectrometry (IC-ESI-MS). LiPF6 was identified as a conducting salt, whereas dimethyl carbonate, ethyl methyl carbonate, and ethylene carbonate were the main solvent components. Cyclohexylbenzene was also detected, which is an additive for overcharge protection. Diethyl carbonate, fluoride, difluorophosphate and several ionic and non-ionic alkyl (fluoro)phosphates were also identified. Importantly, dimethyl fluorophosphate (DMFP) and diethyl fluorophosphate (DEFP) were quantified using HS-GC-MS through the use of an internal standard. DMFP, DEFP, and related compounds are known as chemical warfare agents, and the presence of these materials is of great interest. In the case of this study, these hazardous materials are present but in manageable low concentrations. Nonetheless, the presence of such compounds and their potential release during an accident that may occur during shredding or recycling of large amounts of LIB waste should be considered. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Comprehensive gas chromatography coupled to mass spectrometry for the separation of pesticides in a very complex matrix.

    PubMed

    Mondello, Luigi; Casilli, Alessandro; Tranchida, Peter Quinto; Lo Presti, Maria; Dugo, Paola; Dugo, Giovanni

    2007-11-01

    The present research is focused on the development of a comprehensive two-dimensional gas chromatography-rapid scanning quadrupole mass spectrometric (GC x GC-qMS) methodology for the analysis of trace-amount pesticides contained in a complex real-world sample. Reliable peak assignment was carried out by using a recently developed, dedicated pesticide MS library (for comprehensive GC analysis), characterized by a twin-filter search procedure, the first based on a minimum degree of spectral similarity and the second on the interactive use of linear retention indices (LRI). The library was constructed by subjecting mixtures of commonly used pesticides to GC x GC-qMS analysis and then deriving their pure mass spectra and LRI values. In order to verify the effectiveness of the approach, a pesticide-contaminated red grapefruit extract was analysed. The certainty of peak assignment was attained by exploiting both the enhanced separation power of dual-oven GC x GC and the highly effective search procedure.

  18. ENVIRONMENTAL ANALYSIS BY AB INITIO QUANTUM MECHANICAL COMPUTATION AND GAS CHROMATOGRAPHY/FOURIER TRANSFORM INFRARED SPECTROMETRY.

    EPA Science Inventory

    Computational chemistry, in conjunction with gas chromatography/mass spectrometry/Fourier transform infrared spectrometry (GC/MS/FT-IR), was used to tentatively identify seven tetrachlorobutadiene (TCBD) isomers detected in an environmental sample. Computation of the TCBD infrare...

  19. Discrimination of cherry wines based on their sensory properties and aromatic fingerprinting using HS-SPME-GC-MS and multivariate analysis.

    PubMed

    Xiao, Zuobing; Liu, Shengjiang; Gu, Yongbo; Xu, Na; Shang, Yi; Zhu, Jiancai

    2014-03-01

    Volatiles of cherry wines were extracted by headspace solid phase microextraction (HS-SPME) and analyzed by gas chromatography mass spectrometry (GC-MS), multivariate statistical techniques (such as principal component analysis (PCA) and cluster analysis (CA) and correlation analysis) to differentiate sensory attributes of 3 groups of the wines through characterization of volatiles of cherry wine. Seventy-five volatiles were identified in 9 samples, including 29 esters, 22 alcohols, 8 acids, 3 ketones, 5 aldehydes, and 8 miscellaneous compounds. The PCA results showed that the cherry wines were mainly differentiated by 8 sensory attributes. The samples W2, W4, and W7 were grouped around sweet aromatic and the samples W1, W5, and W9 were highly associated with the sweet, esters, green, bitter, and fermented. Nevertheless, the samples W3, W6, and W8 were located close to the sour, alcoholic, and fruity. The final result of correlation analysis was in conformity with the conclusion of PCA. The CA results showed that the group of W2, W4, and W7, and the group of W1, W5, and W9 had less difference than the group of W3, W6, and W8. The reason should be that esterification reactions and fermentation process during the ageing period was more extended. The results of analyzing revealed that HS-SPME-GC-MS coupled with chemometrics could give an appropriate way of characterizing and classifying the cherry wines. Attributes that represent and discriminate among cherry wines might be made use of a better comprehending of the wines and for being utilized in future work. In addition, several chemometrics were used to classify the type of wines and try to install the relationship between volatiles and sensory property. Especially, PCA clearly revealed that the most contributing compounds for sensory attributes of cherry wines, CA was a more applicable way to distinguish types of cherry wines. Therefore, a feasible method that would be helpful to promote the quality of the wines by improving the winemaking process and analyzing aromatic characteristics of wines. © 2014 Institute of Food Technologists®

  20. Development and Efficacy Testing of Next Generation Cyanide Antidotes

    DTIC Science & Technology

    2013-10-01

    Preparation of mDMTS A-2.2. HPLC method for DMTS determination in Micelles A-2.3. Head-space solid phase micro-extraction- gas chromatography -mass...Simultaneous determination of cyanide and thiocyanate in plasma by chemical ionization gas chromatography mass-spectrometry (CI-GC-MS). Analytical and...min. Peak integration was performed using Star Chromatography Workstation Version 6.20. A-2.3. Head-space solid phase micro-extraction- gas

  1. New Micro-Method for Prediction of Vapor Pressure of Energetic Materials

    DTIC Science & Technology

    2014-07-01

    temperature is recorded as the extrapolated onset temperature (11–12). • Gas chromatography (GC) headspace analysis requires the establishment of an...J. L.; Shinde, K.; Moran, J. Determination of the Vapor Density of Triacetone Triperoxide (TATP) Using a Gas Chromatography Headspace Technique...Propellants Explos. Pyrotech. 2005, 30 (2), 127–30. 14. Chickos, J. S. Sublimation Vapor Pressures as Evaluated by Correlation- Gas Chromatography . J

  2. 76 FR 61647 - Receipt of Several Pesticide Petitions Filed for Residues of Pesticide Chemicals in or on Various...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-05

    ... was required for gas chromatography with mass selective detection (GC/MSD) but not for liquid... detection (LOD = 0.01) and a gas liquid chromatography (GLC) method with a flame photometric detection (LOD... quantification by high performance liquid chromatography with tandem mass spectrometric detection (HPLC/MS/MS...

  3. Comprehensive two-dimensional gas chromatography in combination with rapid scanning quadrupole mass spectrometry in perfume analysis.

    PubMed

    Mondello, Luigi; Casillia, Alessandro; Tranchida, Peter Quinto; Dugo, Giovanni; Dugo, Paola

    2005-03-04

    Single column gas chromatography (GC) in combination with a flame ionization detector (FID) and/or a mass spectrometer is routinely employed in the determination of perfume profiles. The latter are to be considered medium to highly complex matrices and, as such, can only be partially separated even on long capillaries. Inevitably, several monodimensional peaks are the result of two or more overlapping components, often hindering reliable identification and quantitation. The present investigation is based on the use of a comprehensive GC (GC x GC) method, in vacuum outlet conditions, for the near to complete resolution of a complex perfume sample. A rapid scanning quadrupole mass spectrometry (qMS) system, employed for the assignment of GC x GC peaks, supplied high quality mass spectra. The validity of the three-dimensional (3D) GC x GC-qMS application was measured and compared to that of GC-qMS analysis on the same matrix. Peak identification, in all applications, was achieved through MS spectra library matching and the interactive use of linear retention indices (LRI).

  4. Gas flow headspace liquid phase microextraction.

    PubMed

    Yang, Cui; Qiu, Jinxue; Ren, Chunyan; Piao, Xiangfan; Li, Xifeng; Wu, Xue; Li, Donghao

    2009-11-06

    There is a trend towards the use of enrichment techniques such as microextraction in the analysis of trace chemicals. Based on the theory of ideal gases, theory of gas chromatography and the original headspace liquid phase microextraction (HS-LPME) technique, a simple gas flow headspace liquid phase microextraction (GF-HS-LPME) technique has been developed, where the extracting gas phase volume is increased using a gas flow. The system is an open system, where an inert gas containing the target compounds flows continuously through a special gas outlet channel (D=1.8mm), and the target compounds are trapped on a solvent microdrop (2.4 microL) hanging on the microsyringe tip, as a result, a high enrichment factor is obtained. The parameters affecting the enrichment factor, such as the gas flow rate, the position of the microdrop, the diameter of the gas outlet channel, the temperatures of the extracting solvent and of the sample, and the extraction time, were systematically optimized for four types of polycyclic aromatic hydrocarbons. The results were compared with results obtained from HS-LPME. Under the optimized conditions (where the extraction time and the volume of the extracting sample vial were fixed at 20min and 10mL, respectively), detection limits (S/N=3) were approximately a factor of 4 lower than those for the original HS-LPME technique. The method was validated by comparison of the GF-HS-LPME and HS-LPME techniques using data for PAHs from environmental sediment samples.

  5. Cryogenic Collection of Complete Subsurface Samples for Molecular Biological Analysis

    DTIC Science & Technology

    2012-05-01

    Nitrate was analyzed by ion chromatography ( Dionex IC25) and had a detection limit of 0.01 mg/L. Fluorescein was measured using a flow-through...dissolved oxygen (DO) with a flow through electrode, Nitrate by ion chromatography , and fluorescein with a flow through fluorometer. 1.9 LARGE...measured by headspace gas chromatography (HP 7694 Headspace Sampler attached to an HP 5890 GC with an FID detector). The GC method had a detection

  6. Authentication of organically and conventionally grown basils by gas chromatograpy/mass spectrometry chemical profiles

    USDA-ARS?s Scientific Manuscript database

    Basil plants cultivated by organic and conventional farming practices were differentiated using gas chromatography/mass spectrometry (GC/MS) and chemometric methods. The two-way GC/MS data sets were baseline-corrected and retention time-aligned prior to data processing. Two self-devised fuzzy clas...

  7. Optimisation of solid-phase microextraction combined with gas chromatography-mass spectrometry based methodology to establish the global volatile signature in pulp and skin of Vitis vinifera L. grape varieties.

    PubMed

    Perestrelo, Rosa; Barros, António S; Rocha, Sílvia M; Câmara, José S

    2011-09-15

    The volatiles (VOCs) and semi-volatile organic compounds (SVOCs) responsible for aroma are mainly present in skin of grape varieties. Thus, the present investigation is directed towards the optimisation of a solvent free methodology based on headspace-solid-phase microextraction (HS-SPME) combined with gas chromatography-quadrupole mass spectrometry (GC-qMS) in order to establish the global volatile composition in pulp and skin of Bual and Bastardo Vitis vinifera L. varieties. A deep study on the extraction-influencing parameters was performed, and the best results, expressed as GC peak area, number of identified compounds and reproducibility, were obtained using 4 g of sample homogenised in 5 mL of ultra-pure Milli-Q water in a 20 mL glass vial with addition of 2g of sodium chloride (NaCl). A divinylbenzene/carboxen/polydimethylsiloxane fibre was selected for extraction at 60°C for 45 min under continuous stirring at 800 rpm. More than 100 VOCs and SVOCs, including 27 monoterpenoids, 27 sesquiterpenoids, 21 carbonyl compounds, 17 alcohols (from which 2 aromatics), 10 C(13) norisoprenoids and 5 acids were identified. The results showed that, for both grape varieties, the levels and number of volatiles in skin were considerably higher than those observed in pulp. According to the data obtained by principal component analysis (PCA), the establishment of the global volatile signature of grape and the relationship between different part of grapes-pulp and skin, may be an useful tool to winemaker decision to define the vinification procedures that improves the organoleptic characteristics of the corresponding wines and consequently contributed to an economic valorization and consumer acceptance. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Characterisation of odorants in roasted stem tea using gas chromatography-mass spectrometry and gas chromatography-olfactometry analysis.

    PubMed

    Sasaki, Tetsuya; Koshi, Erina; Take, Harumi; Michihata, Toshihide; Maruya, Masachika; Enomoto, Toshiki

    2017-04-01

    Roasted stem tea has a characteristic flavour, which is obtained by roasting tea stems, by-product of green tea production. This research aims to understand the characteristic odorants in roasted stem tea by comparing it to roasted leaf tea. We revealed potent odorants in commercial roasted stem tea using gas chromatography-mass spectrometry (GC-MS) and gas chromatography-olfactometry with aroma extract dilution analysis (AEDA). The difference between roasted stem and leaf tea derived from the same tea plants were investigated using GC-MS. Pyrazine compounds exhibited a roasted odour and high flavour dilution (FD) factors, as determined via AEDA. Roasted stem tea was richer in these pyrazines than roasted leaf tea. Geraniol and linalool exhibited high FD factors and a floral odour, and roasted stem tea was richer in these compounds than roasted leaf tea. These results may have a positive impact on the development of tea products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. IDENTIFICATION OF NEW OZONE DISINFECTION BY PRODUCTS IN DRINKING WATER

    EPA Science Inventory

    Using a combination of spectral identification techniques-gas chromatography coupled with low- and high-resolution electron-impact mass spectrometry (GC/EI-MS), low- and high-resolution chemical ionization mass spectrometry (GC/CI-MS), and infrared spectroscopy (GC/ IR)-we identi...

  10. GC/HRSIR as a Complementary Technique to GC/ECNIMS

    EPA Science Inventory

    Gas chromatography/electron capture negative ion mass spectrometry (GC/ECNIMS) is a highly selective and sensitive technique for the analysis of appropriate analytes in complex matrices. Its major drawback is often the lack of fragmentation indicative of structure that can be use...

  11. [Simultaneous determination of cocaine and its metabolite ecgonine methyl ester in human blood using microwave extraction-gas chromatography].

    PubMed

    Wang, Xiaobo; Ye, Nengsheng; Wang, Jifen; Gu, Xuexin

    2010-07-01

    A method was developed for the simultaneous determination of cocaine (COC) and its metabolite ecgonine methyl ester (EME) in human blood using gas chromatography-mass spectrometry (GC-MS) and gas chromatography-flame ionization detection (GC-FID). The blood sample was prepared by microwave extraction (MWE). The optimal parameters of MWE were as follows: 6 mL of chloroform-isopropanol (9: 1, v/v) mixture as extraction solvent, the pH value of the sample was adjusted at 10.0 with 0.05 mol/L Na2CO3-NaHCO3 buffer, the extraction was performed at 40 degrees C for 6 min. The COC and EME in the extract were qualified using GC-MS and quantitated using GC-FID. The average recoveries of COC and EME were from 79.91% to 99.85%, the relative standard deviations were less than 3.10%, and the limits of detection (LOD) were 60 and 40 mg/L, respectively. In the method COC and EME were detected without derivatization. The method is rapid, accurate and sensitive, and can be used for the simultaneous determination of COC and EME in blood samples.

  12. Comparison of different mass spectrometric approaches coupled to gas chromatography for the analysis of organochlorine pesticides in serum samples.

    PubMed

    Fang, Jing; Wu, Qian; Zhao, Yun; Zhao, Hongzhi; Xu, Shunqing; Cai, Zongwei

    2017-01-01

    Gas chromatography-triple quadrupole mass spectrometry (GC-QqQMS) was applied for the determination of eight organochlorine pesticides (OCPs) in human serum. OCPs were extracted from the serum sample by solid phase extraction (SPE) and analyzed by gas chromatography mass spectrometry (GC-MS) or gas chromatography tandem mass spectrometry (GC-MS/MS). Electron ionization (EI) and negative chemical ionization (NCI) under two data acquisition modes, namely selected ion monitoring (SIM) and multiple reaction monitoring (MRM), were compared. The use of MRM generally provided higher selectivity and sensitivity because less interference from the sample matrix existed. The EI mode is more suitable for less electronegative compounds such as dichlorodiphenyldichloroethanes (DDDs) with detection limits ranging from 0.0060 to 0.060ng/mL. In the NCI mode, MRM analysis provided good and lower detection limits (0.0011-0.0030ng/mL) for pesticides containing more chlorines. The methods were validated by analyzing the pesticides in spiked serum at different levels with recoveries ranged from 83% to 116% and relative standard deviations of less than 10%. The developed method was applied for the determination of the OCPs in real human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Rapid determination of pyridine derivatives by dispersive liquid-liquid microextraction coupled with gas chromatography/gas sensor based on nanostructured conducting polypyrrole.

    PubMed

    Pirsa, Sajad; Alizadeh, Naader

    2011-12-15

    Polypyrrole (PPy) gas sensor has been prepared by polymerization of pyrrole on surfaces of commercial polymer fibers in the presence of an oxidizing agent. The sensing behavior of PPy gas sensor was investigated in the presence of pyridine derivatives. The resistive responses of the PPy gas sensor to pyridine derivatives were in the order of quinoline>pyridine>4-methyl pyridine and 2-methyl pyridine. The PPy gas sensor was used as gas chromatography (GC) detector and exhibited linear responses to pyridine derivatives in the ranges 40-4,000 ng. Dispersive liquid-liquid microextraction (DLLME) combined with GC/PPy gas sensor has been developed for simultaneous determination of pyridine derivatives and quinoline. The purposed method was used for determination of pyridine derivatives from cigarette smoke. The GC runs were completed in 4 min. The reproducibility of this method is suitable and good standard deviations were obtained. RSD value is less than 10% for all analytes. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Acrylamide: formation, occurrence in food products, detection methods, and legislation.

    PubMed

    Arvanitoyannis, Ioannis S; Dionisopoulou, Niki

    2014-01-01

    This review aims at summarizing the most recent updates in the field of acrylamide (AA) formation (mechanism, conditions) and the determination of AA in a number of foods (fried or baked potatoes, chips, coffee, bread, etc). The methods applied for AA detection [Capillary Electrophoresis-Mass Spectrometry (CE-MS), Liquid Chromatography-Mass Spectrometry (LC-MS), Non-Aqueous Capillary Electrophoresis (NACE), High Performance Liquid Chromatography-Mass Spectrometry (HPLC-MS), Pressurized Fluid Extraction (PFE), Matrix Solid-Phase Dispersion (MSPD), Gas Chromatography-Mass Spectrometry (GC-MS), Solid-Phase MicroExtraction-Gas Chromatography (SPME-GC), Enzyme Linked Immunosorbent Assay (ELISA), and MicroEmulsion ElectroKinetic Chromatography (MEEKC) are presented and commented. Several informative figures and tables are included to show the effect of conditions (temperature, time) on the AA formation. A section is also included related to AA legislation in EU and US.

  15. Technical Note: Fast two-dimensional GC-MS with thermal extraction for anhydro-sugars in fine aerosols

    EPA Science Inventory

    A fast two-dimensional gas chromatography (GC-MS) method that uses heart-cutting and thermal extraction (TE) and requires no chemical derivatization is developed for the determination of anhydro-sugars in fine aerosols. Evaluation of the TE-GC-GC-MS method shows high average rela...

  16. Determination and evaluation of gas holdup time with the quadratic equation model and comparison with nonlinear equation models for isothermal gas chromatography

    PubMed Central

    Wu, Liejun; Chen, Maoxue; Chen, Yongli; Li, Qing X.

    2013-01-01

    Gas holdup time (tM) is a basic parameter in isothermal gas chromatography (GC). Determination and evaluation of tM and retention behaviors of n-alkanes under isothermal GC conditions have been extensively studied since the 1950s, but still remains unresolved. The difference equation (DE) model [J. Chromatogr. A 1260:215–223] reveals retention behaviors of n-alkanes excluding tM, while the quadratic equation (QE) model [J. Chromatogr. A 1260:224–231] including tM is suitable for applications. In the present study, tM values were calculated with the QE model, which is referred to as tMT, evaluated and compared with other three typical nonlinear models. The QE model gives an accurate estimation of tM in isothermal GC. The tMT values are highly accurate, stable, and easy to calculate and use. There is only one tMT value at each GC condition. The proper classification of tM values can clarify their disagreement and facilitate GC retention data standardization for which tMT values are promising reference tM values. PMID:23726077

  17. Stability Study of Algerian Nigella sativa Seeds Stored under Different Conditions

    PubMed Central

    Ahamad Bustamam, Muhammad Safwan; Hadithon, Kamarul Arifin; Rukayadi, Yaya; Lajis, Nordin

    2017-01-01

    In a study to determine the stability of the main volatile constituents of Nigella sativa seeds stored under several conditions, eight storage conditions were established, based on the ecological abiotic effects of air, heat, and light. Six replicates each were prepared and analyzed with Headspace-Gas Chromatography-Mass Spectrometry (HS-GC-MS) for three time points at the initial (1st day (0)), 14th (1), and 28th (2) day of storage. A targeted multivariate analysis of Principal Component Analysis revealed that the stability of the main volatile constituents of the whole seeds was better than that of the ground seeds. Exposed seeds, whole or ground, were observed to experience higher decrement of the volatile composition. These ecofactors of air, heat, and light are suggested to be directly responsible for the loss of volatiles in N. sativa seeds, particularly of the ground seeds. PMID:28255502

  18. Aroma Characterization and Safety Assessment of a Beverage Fermented by Trametes versicolor.

    PubMed

    Zhang, Yanyan; Fraatz, Marco Alexander; Müller, Julia; Schmitz, Hans-Joachim; Birk, Florian; Schrenk, Dieter; Zorn, Holger

    2015-08-12

    A cereal-based beverage was developed by fermentation of wort with the basidiomycete Trametes versicolor. The beverage possessed a fruity, fresh, and slightly floral aroma. The volatiles of the beverage were isolated by liquid-liquid extraction (LLE) and additionally by headspace solid phase microextraction (HS-SPME). The aroma compounds were analyzed by a gas chromatography system equipped with a tandem mass spectrometer and an olfactory detection port (GC-MS/MS-O) followed by aroma (extract) dilution analysis. Thirty-four different odor impressions were perceived, and 27 corresponding compounds were identified. Fifteen key odorants with flavor dilution (FD) factors ranging from 8 to 128 were quantitated, and their respective odor activity values (OAVs) were calculated. Six key odorants were synthesized de novo by T. versicolor. Furthermore, quantitative changes during the fermentation process were analyzed. To prepare for the market introduction of the beverage, a comprehensive safety assessment was performed.

  19. GC in Environmental Analysis

    ERIC Educational Resources Information Center

    Gosink, Thomas A.

    1975-01-01

    Gas chromatography can be used to quantitate various gases, complex organic molecules, metals, anions, and pesticides in the lab or in the field. Important advances in gas chromatography and how they directly apply to environmental analyses plus suggestions where they will be of importance to environmental chemists are discussed. (BT)

  20. Analysis of chemical signals in red fire ants by gas chromatography and pattern recognition techniques

    USDA-ARS?s Scientific Manuscript database

    The combination of gas chromatography and pattern recognition (GC/PR) analysis is a powerful tool for investigating complicated biological problems. Clustering, mapping, discriminant development, etc. are necessary to analyze realistically large chromatographic data sets and to seek meaningful relat...

  1. CAPILLARY GAS CHROMATOGRAPHY-ATOMIC EMISSION DETECTION METHOD FOR THE DETERMINATION OF PENTYLATED ORGANOTIN COMPOUNDS: INTERLABORATORY STUDY

    EPA Science Inventory

    A capillary gas chromatography-atomic emission detection (GC-AED) method was developed for the U. S. Environmental Protection Agency's Environmental Monitoring Systems Laboratory in Las Vegas, NV, for determination of selected organotin compounds. Here we report on an interlabora...

  2. IDENTIFICATION OF BIS(2-CHLOROETHYL) ETHER HYDROLYSIS PRODUCTS BY DIRECT AQUEOUS INJECTION GC/FT-IR

    EPA Science Inventory

    Gas chromatography coupled to Fourier-transform infrared spectroscopy (GC/FT-IR) is rapidly becoming an accepted analytical technique complementary to GC/mass spectroscopy for identifying organic compounds in mixtures at low to moderate concentrations. irect aqueous injection (DA...

  3. Multiple inert gas elimination technique by micropore membrane inlet mass spectrometry--a comparison with reference gas chromatography.

    PubMed

    Kretzschmar, Moritz; Schilling, Thomas; Vogt, Andreas; Rothen, Hans Ulrich; Borges, João Batista; Hachenberg, Thomas; Larsson, Anders; Baumgardner, James E; Hedenstierna, Göran

    2013-10-15

    The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.

  4. Metabolism and nephrotoxicity of indan in male Fischer 344 rats.

    PubMed

    Servé, M P; Ferry, M J; Yu, K O; Olson, C T; Hobson, D W

    1990-01-01

    Indan, a component of fuels, solvents, and varnishes, is metabolized in male Fischer 344 rats to 1-indanol, 2-indanol, 5-indanol, 1-indanone, 2-indanone, 2-hydroxy-1-indanone, cis-1,2-indandiol, and trans-1,2-indandiol. The metabolites were identified using the techniques of gas chromatography (GC) and gas chromatography/mass spectrometry (GC/MS). The rats treated with indan demonstrated the classic lesions of hydrocarbon-induced nephropathy. The kidney damage produced was less than that found for tetralin and other branched-chain acyclic hydrocarbons.

  5. Detection of virgin coconut oil adulteration with animal fats using quantitative cholesterol by GC × GC-TOF/MS analysis.

    PubMed

    Xu, Baocheng; Li, Peiwu; Ma, Fei; Wang, Xiuping; Matthäus, Bertrand; Chen, Ran; Yang, Qingqing; Zhang, Wen; Zhang, Qi

    2015-07-01

    A new method based on the cholesterol level was developed to detect the presence of animal fats in virgin coconut oil (VCO). In this study, the sterols in VCO and animal fats was separated using conventional one-dimensional gas chromatography (1D GC) and comprehensive two-dimensional gas chromatography (GC×GC). Compared with 1D GC, the GC×GC system could obtain a complete baseline separation of the sterol trimethylsilyl ethers derived from cholesterol and cholestanol, so that the cholesterol content in pure VCO and false VCO adulterated with animal fats could be accurately determined. Cholesterol, a main sterol found in animal fats, represented less than 5mg/kg of VCO. The study demonstrated that the determination of the cholesterol level in VCO could be used for reliable detection of the presence of lard, chicken fat, mutton tallow, beef tallow, or their mixture in VCO at a level as little as 0.25%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Screening of inorganic gases released from firework-rockets by a gas chromatography/whistle-accelerometer method.

    PubMed

    Chen, Kuan-Fu; Wu, Hui-Hsin; Lin, Chien-Hung; Lin, Cheng-Huang

    2013-08-30

    The use of an accelerometer for detecting inorganic gases in gas chromatography (GC) is described. A milli-whistle was connected to the outlet of the GC capillary and was used instead of a classical GC detector. When the GC carrier gases and the sample gases pass through the milli-whistle, a sound is produced, leading to vibrational changes, which can be recorded using an accelerometer. Inorganic gases, including SO2, N2 and CO2, which are released from traditional Chinese firework-rockets at relatively high levels as the result of burning the propellant and explosive material inside could be rapidly determined using the GC/whistle-accelerometer system. The method described herein is safe, the instrumentation is compact and has potential to be modified so as to be portable for use in the field. It also can be used in conjunction with FID (flame ionization detector) or TCD (thermal conductivity detector), in which either no response for FID (CO2, N2, NO2, SO2, etc.) or helium gas is needed for TCD, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Demonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors.

    PubMed

    Liu, Jing; Gupta, Naveen K; Wise, Kensall D; Gianchandani, Yogesh B; Fan, Xudong

    2011-10-21

    This paper reports the investigation of a micro-gas chromatography (μGC) system that utilizes an array of miniaturized motionless Knudsen pumps (KPs) as well as microfabricated separation columns and optical detectors. A prototype system was built to achieve a flow rate of 1 mL min(-1) and 0.26 mL min(-1) for helium and dry air, respectively, when they were used as carrier gas. This system was then employed to evaluate GC performance compromises and demonstrate the ability to separate and detect gas mixtures containing analytes of different volatilities and polarities. Furthermore, the use of pressure programming of the KP array was demonstrated to significantly shorten the analysis time while maintaining a high detection resolution. Using this method, we obtained a high resolution detection of 5 alkanes of different volatilities within 5 min. Finally, we successfully detected gas mixtures of various polarities using a tandem-column μGC configuration by installing two on-column optical detectors to obtain complementary chromatograms.

  8. Guilty by dissociation-development of gas chromatography-mass spectrometry (GC-MS) and other rapid screening methods for the analysis of 13 diphenidine-derived new psychoactive substances (NPSs).

    PubMed

    Geyer, Pierre M; Hulme, Matthew C; Irving, Joseph P B; Thompson, Paul D; Ashton, Ryan N; Lee, Robert J; Johnson, Lucy; Marron, Jack; Banks, Craig E; Sutcliffe, Oliver B

    2016-11-01

    The prevalence of new psychoactive substances (NPSs) in forensic casework has increased prominently in recent years. This has given rise to significant legal and analytical challenges in the identification of these substances. The requirement for validated, robust and rapid testing methodologies for these compounds is obvious. This study details the analysis of 13 synthesised diphenidine derivatives encountered in casework using presumptive testing, thin layer chromatography and gas chromatography-mass spectrometry (GC-MS). Specifically, the validated GC-MS method provides, for the first time, both a general screening method and quantification of the active components for seized solid samples, both in their pure form and in the presence of common adulterants. Graphical Abstract Chemical synthesis and forensic analysis of 13 diphenidine-derived new psychoactive substance(s).

  9. Ultratrace determination of total and available cyanides in industrial wastewaters through a rapid headspace-based sample preparation and gas chromatography with nitrogen phosphorous detection analysis.

    PubMed

    Marton, Daniele; Tapparo, Andrea; Di Marco, Valerio B; Repice, Carla; Giorio, Chiara; Bogialli, Sara

    2013-07-26

    A new analytical method for the determination of both available (free and weak acid dissociable, WAD) and total cyanides in industrial wastewaters has been developed. It is based on the static headspace (HS) sampling procedure followed by a GC separation and the selective nitrogen-phosphorous detection (NPD), in which different thermal treatment allows the speciation of total and available cyanides. Detection limits (0.5μg/L), recovery (84.7-114.6% for free and 76.8-121.5% for total cyanides) and precision (5% at 5μg/L), evaluated on both real and synthetic samples, were fit-for-purpose for the legal requirement (5μg/L) enforced in the Venice lagoon, without significant interfering species. In addition, analytical results of the HS-GC-NPD method have been compared with those obtained using the 4500 CN and EN ISO 14403 official methods for the determination of total and free cyanides, respectively. The new method has been successfully applied for the determination of cyanide concentrations in main influent and final effluent to the Venice lagoon to verify the efficiency of the industrial wastewater treatment plant of Porto Marghera (Venice, Italy). The capability of the proposed method to detect the WAD cyanides has been tested by studying the acid dissociation of K2[Ni(CN)4]. An unexpected speciation picture was obtained for this complex, which suggests that the present definition and analytical strategy of this cyanide class should be reconsidered. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Volatile Compound Profiling by HS-SPME/GC-MS-FID of a Core Olive Cultivar Collection as a Tool for Aroma Improvement of Virgin Olive Oil.

    PubMed

    García-Vico, Lourdes; Belaj, Angjelina; Sánchez-Ortiz, Araceli; Martínez-Rivas, José M; Pérez, Ana G; Sanz, Carlos

    2017-01-14

    Virgin olive oil (VOO) is the only food product requiring official sensory analysis to be classified in commercial categories, in which the evaluation of the aroma plays a very important role. The selection of parents, with the aim of obtaining new cultivars with improved oil aroma, is of paramount importance in olive breeding programs. We have assessed the volatile fraction by headspace-solid-phase microextraction/gas chromatography-mass spectrometry-flame ionization detection (HS-SPME/GC-MS-FID) and the deduced aroma properties of VOO from a core set of olive cultivars (Core-36) which possesses most of the genetic diversity found in the World Olive Germplasm Collection (IFAPA Alameda del Obispo) located in Cordoba, Spain. The VOO volatile fractions of Core-36 cultivars display a high level of variability. It is mostly made of compounds produced from polyunsaturated fatty acids through the lipoxygenase pathway, which confirms to be a general characteristic of the olive species ( Olea europaea L.). The main group of volatile compounds in the oils was six straight-chain carbon compounds derived from linolenic acid, some of them being the main contributors to the aroma of the olive oils according to their odor activity values (OAV). The high level of variability found for the volatile fraction of the oils from Core-36 and, therefore, for the aroma odor notes, suggest that this core set may be a very useful tool for the choice of optimal parents in olive breeding programs in order to raise new cultivars with improved VOO aroma.

  11. Headspace-Solid Phase Microextraction Approach for Dimethylsulfoniopropionate Quantification in Solanum lycopersicum Plants Subjected to Water Stress

    PubMed Central

    Catola, Stefano; Kaidala Ganesha, Srikanta Dani; Calamai, Luca; Loreto, Francesco; Ranieri, Annamaria; Centritto, Mauro

    2016-01-01

    Dimethylsulfoniopropionate (DMSP) and dimethyl sulphide (DMS) are compounds found mainly in marine phytoplankton and in some halophytic plants. DMS is a globally important biogenic volatile in regulating of global sulfur cycle and planetary albedo, whereas DMSP is involved in the maintenance of plant-environment homeostasis. Plants emit minute amounts of DMS compared to marine phytoplankton and there is a need for hypersensitive analytic techniques to enable its quantification in plants. Solid Phase Micro Extraction from Head Space (HS-SPME) is a simple, rapid, solvent-free and cost-effective extraction mode, which can be easily hyphenated with GC-MS for the analysis of volatile organic compounds. Using tomato (Solanum lycopersicum) plants subjected to water stress as a model system, we standardized a sensitive and accurate protocol for detecting and quantifying DMSP pool sizes, and potential DMS emissions, in cryoextracted leaves. The method relies on the determination of DMS free and from DMSP pools before and after the alkaline hydrolysis via Headspace-Solid Phase Micro Extraction-Gas Chromatography-Mass Spectrometry (HS-SPME-GC-MS). We found a significant (2.5 time) increase of DMSP content in water-stressed leaves reflecting clear stress to the photosynthetic apparatus. We hypothesize that increased DMSP, and in turn DMS, in water-stressed leaves are produced by carbon sources other than direct photosynthesis, and function to protect plants either osmotically or as antioxidants. Finally, our results suggest that SPME is a powerful and suitable technique for the detection and quantification of biogenic gasses in trace amounts. PMID:27602039

  12. Methods of Analysis - Determination of Pyrethroid Insecticides in Water and Sediment Using Gas Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Hladik, Michelle; Smalling, Kelly L.; Kuivila, Kathryn

    2009-01-01

    A method for the determination of 14 pyrethroid insecticides in environmental water and sediment samples is described. The method was developed by the U.S. Geological Survey in response to increasing concern over the effects of pyrethroids on aquatic organisms. The pyrethroids included in this method are ones that are applied to many agricultural and urban areas. Filtered water samples are extracted for pyrethroids using solid-phase extraction (SPE) with no additional cleanup steps. Sediment and soil samples are extracted using a microwave-assisted extraction system, and the pyrethroids of interest are separated from co-extracted matrix interferences by passing the extracts through stacked graphitized carbon and alumina SPE cartridges, along with the use of high-performance liquid chromatography and gel-permeation chromatography (HPLC/GPC). Quantification of the pyrethroids from the extracted water and sediment samples is done using gas chromatography with mass spectrometry (GC/MS) or gas chromatography with tandem mass spectrometry (GC/MS/MS). Recoveries in test water samples fortified at 10 ng/L ranged from 83 to 107 percent, and recoveries in test sediment samples fortified at 10 ug/kg ranged from 82 to 101 percent; relative standard deviations ranged from 5 to 9 percent in the water samples and 3 to 9 percent in the sediment samples. Method detection limits (MDLs), calculated using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), in water ranged from 2.0 to 6.0 ng/L using GC/MS and 0.5 to 1.0 ng/L using GC/MS/MS. For sediment, the MDLs ranged from 1.0 to 2.6 ug/kg dry weight using GC/MS and 0.2 to 0.5 ug/kg dry weight using GC/MS/MS. The matrix-spike recoveries for each compound, when averaged for 12 environmental water samples, ranged from 84 to 96 percent, and when averaged for 27 environmental sediment samples, ranged from 88 to 100 percent.

  13. Determination of red blood cell fatty acid profiles: Rapid and high-confident analysis by chemical ionization-gas chromatography-tandem mass spectrometry.

    PubMed

    Schober, Yvonne; Wahl, Hans Günther; Renz, Harald; Nockher, Wolfgang Andreas

    2017-01-01

    Cellular fatty acid (FA) profiles have been acknowledged as biomarkers in various human diseases. Nevertheless, common FA analysis by gas chromatography mass spectrometry (GC-MS) requires long analysis time. Hence, there is a need for feasible methods for high throughput analysis in clinical studies. FA was extracted from red blood cells (RBC) and derivatized to fatty acid methyl esters (FAME). A method using gas chromatography tandem mass spectrometry (GC-MS/MS) with ammonia-induced chemical ionization (CI) was developed for the analysis of FA profiles in human RBC. We compared this method with classical single GC-MS using electron impact ionization (EI). The FA profiles of 703 RBC samples were determined by GC-MS/MS. In contrast to EI ammonia-induced CI resulted in adequate amounts of molecular ions for further fragmentation of FAME. Specific fragments for confident quantification and fragmentation were determined for 45 FA. The GC-MS/MS method has a total run time of 9min compared to typical analysis times of up to 60min in conventional GC-MS. Intra and inter assay variations were <10% for all FA analyzed. Analysis of RBC FA composition revealed an age-dependent increase of the omega-3 eicosapentaenoic and docosahexaenoic acid, and a decline of the omega-6 linoleic acid with a corresponding rise of the omega-3 index. The combination of ammonia-induced CI and tandem mass spectrometry after GC separation allows for high-throughput, robust and confident analysis of FA profiles in the clinical laboratory. Copyright © 2016. Published by Elsevier B.V.

  14. Discovering Volatile Chemicals from Window Weatherstripping through Solid-Phase Microextraction/Gas Chromatography-Mass Spectrometry

    ERIC Educational Resources Information Center

    Rosu, Cornelia; Cueto, Rafael; Veillion, Lucas; David, Connie; Laine, Roger A.; Russo, Paul S.

    2017-01-01

    Volatile compounds from polymeric materials such as weatherstripping were identified by solid-phase microextraction (SPME), a solvent-free analytical method, coupled to gas chromatography-mass spectrometry (GC-MS). These compounds, originating from additives and fillers used in weatherstripping processing, were mostly polycyclic aromatic…

  15. SIMULTANEOUS DETERMINATION OF ORGANOTIN, ORGANOLEAD, AND ORGANOMERCURY COMPOUNDS IN ENVIRONMENTAL SAMPLES USING CAPILLARY GAS CHROMATOGRAPHY WITH ATOMIC EMISSION DETECTION

    EPA Science Inventory

    As part of a continuing evaluation of new analytical and sample preparation techniques conducted by the US Environmental Protection Agency (EPA), the use of capillary gas chromatography with atomic emission detection (GC-AED) for the simultaneous determination of organotin, organ...

  16. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    ERIC Educational Resources Information Center

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  17. Determination of BROMATE AT PARTS-PER-TRILLION LEVELS BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY WITH NEGATIVE CHEMICAL IONIZATION

    EPA Science Inventory

    The ozonation of bromide-containing source waters produces bromate as a class 2B carcinogenic disinfection by-product. The present work describes the determination of bromate by gas chromatography-negative chemical ionization mass spectrometry (GC-NCIMS) following a bromate react...

  18. EPA Air Method, Toxic Organics - 15 (TO-15): Determination of Volatile Organic Compounds (VOCs) in Air Collected in Specially-Prepared Canisters and Analyzed by Gas Chromatography/Mass Spectrometry (GC/MS)

    EPA Pesticide Factsheets

    Method T)-15 describes procedures for for preparation and analysis of air samples containing volatile organic compounds collected in specially-prepared canisters, using gas chromatography-mass spectrometry.

  19. Volatile constituents of commercial imported and domestic black-ripe table olives (Olea europaea)

    USDA-ARS?s Scientific Manuscript database

    Volatile constituents of commercial black-ripe table olives (Olea europaea) from the United States, Spain, Egypt and Morocco were analyzed by gas chromatography and gas chromatography-mass spectrometry (GC-MS). Dynamic headspace sampling was used to isolate a variety of aldehydes, alcohols, esters, ...

  20. Headspace-Solid-Phase Microextraction-Gas Chromatography as Analytical Methodology for the Determination of Volatiles in Wild Mushrooms and Evaluation of Modifications Occurring during Storage

    PubMed Central

    Costa, Rosaria; De Grazia, Selenia; Grasso, Elisa; Trozzi, Alessandra

    2015-01-01

    Mushrooms are sources of food, medicines, and agricultural means. Not much is reported in the literature about wild species of the Mediterranean flora, although many of them are traditionally collected for human consumption. The knowledge of their chemical constituents could represent a valid tool for both taxonomic and physiological characterizations. In this work, a headspace-solid-phase microextraction (HS-SPME) method coupled with GC-MS and GC-FID was developed to evaluate the volatile profiles of ten wild mushroom species collected in South Italy. In addition, in order to evaluate the potential of this analytical methodology for true quantitation of volatiles, samples of the cultivated species Agaricus bisporus were analyzed. The choice of this mushroom was dictated by its ease of availability in the food market, due to the consistent amounts required for SPME method development. For calibration of the main volatile compounds, the standard addition method was chosen. Finally, the assessed volatile composition of A. bisporus was monitored in order to evaluate compositional changes occurring during storage, which represents a relevant issue for such a wide consumption edible product. PMID:25945282

  1. Nanodetection of the disinfection by-products on GC-MS techniques

    NASA Astrophysics Data System (ADS)

    Ristoiu, Dumitru; Haydee, Melinda; Ristoiu, Tania

    2009-01-01

    Exposures to disinfection by-products (DBPs) in residential drinking water occur through multiple routes and vary across the population because of differences in the amount and ways people use water. Municipal water in the Romania is disinfected, with chlorine being the most common disinfectant agent. Disinfection of water, in additional to having the benefit of destroying microbes that can transmit diseases, has the drawback of producing a series of compounds known as disinfection by-products (DBPs). Chlorination produces many compounds containing chlorine and/or bromine, some of which have been shown to be carcinogenic, mutagenic, and/or teratogenic in animal studies. The most abundant class of DBPs that result from chlorination of drinking water are trihalomethanes (THMs) - chloroform (CHCl3), dichlorobromomethane (CHCl2Br), dibromochloromethane (CHBr2Cl) and bromoform (CHBr3). The most predominant THM species was CHCl3 and it highest concentration was 85•106 ng/m3. The others THMs compounds concentration were lower, between 65•104 ng/m3 and 12•106 ng/m3. THMs compounds were analyzed on gas chromatography coupled with mass spectrometer detector (GC-MS) and head space technique (HS) was used for all analysis.

  2. Comparison of two derivatization methods for the analysis of short chain fatty acids in the ambient aerosol using GC-MS

    NASA Astrophysics Data System (ADS)

    Kim, G.; Jeon, S.

    2016-12-01

    Fatty acids are one of the important compound classes in the polar organic fraction of ambient aerosols. Among them, short chain fatty acids play a significant role in the atmospheric transformation processes. For short-chain acids, the bottleneck of analysis has been the difficulty of sample preparation due to the high solubility and volatility. To overcome this problem, derivatization of polar organic fraction is widely used with silylation reagents to increase the resolution and sensitivity. Two different derivatization procedures; (1) using the tertbutyldimethylsilyl (TBDMS) derivatization and (2) the headspace-solid phase microextraction (HS-SPME) with in-fiber derivatization are compared using gas chromatography-mass spectrometry (GC-MS). At the second method, simultaneous derivatization and extraction were performed by a poly acrylate (PA) coated fiber doped with pyrenyldiazomethane (PDAM). We investigated the chromatographic property and relative sensitivities of each individual short chain acids according to two different derivatization procedures. For the method validation, the linearity, recovery and method detection limit (MDL) were compared. Also, two derivatization methods were applied to the ambient aerosol samples and evaluated with respect to the effectiveness.

  3. HS-SPME-GC-FID method for detection and quantification of Bacillus cereus ATCC 10702 mediated 2-acetyl-1-pyrroline.

    PubMed

    Deshmukh, Yogita; Khare, Puja; Patra, D D; Nadaf, Altafhusain B

    2014-01-01

    A rapid micro-scale solid-phase micro-extraction (SPME) procedure coupled with gas-chromatography with flame ionized detector (GC-FID) was used to extract parts per billion levels of a principle basmati aroma compound "2-acetyl-1-pyrroline" (2-AP) from bacterial samples. In present investigation, optimization parameters of bacterial incubation period, sample weight, pre-incubation time, adsorption time, and temperature, precursors and their concentrations has been studied. In the optimized conditions, detection of 2-AP produced by Bacillus cereus ATCC10702 using only 0.5 g of sample volume was 85 μg/kg. Along with 2-AP, 15 other compounds produced by B. cereus were also reported out of which 14 were reported for the first time consisting mainly of (E)-2-hexenal, pentadecanal, 4-hydroxy-2-butanone, n-hexanal, 2-6-nonadienal, 3-methoxy-2(5H) furanone and 2-acetyl-1-pyridine and octanal. High recovery of 2-AP (87 %) from very less amount of B. cereus samples was observed. The method is reproducible fast and can be used for detection of 2-AP production by B. cereus. © 2014 American Institute of Chemical Engineers.

  4. One-step multiple component isolation from the oil of Crinitaria tatarica (Less.) Sojak. by preparative capillary gas with characterization by spectroscopic and spectrometric techniques and evaluation of biological activity

    USDA-ARS?s Scientific Manuscript database

    In the present work multiple component isolation from the oil of Crinitaria tatarica (Less.) Sojak. by Preparative Capillary Gas Chromatography (PCGC) with characterization by mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy have been carried out. Gas chromatography (GC-FID) ...

  5. Vapor Pressure of Bis-(2-chloroethyl)ethylamine (HN1)

    DTIC Science & Technology

    2013-10-01

    coefficient of the compound. 4 Analysis of an aliquot of the material by 13 C nuclear magnetic resonance (NMR) spectroscopy, gas chromatography ...ACRONYMS AND ABBREVIATIONS CW chemical warfare ECBC U.S. Army Edgewood Chemical Biological Center GC gas chromatography HN1 bis-(2...compounds for determining vapor pressures. The arrows indicate the direction of flow of the nitrogen carrier gas

  6. ALTERNATIVE DISINFECTANTS FOR DRINKING WATER

    EPA Science Inventory

    Using a combination of spectral identification techniques - gas chromatography coupled with low-and high-resolution electron-impact mass spectrometry (GC/EI-MS), low-and high-resolution chemical ionization mass spectrometry (GC/CI-MS), and Fourier transform infrared spectroscopy ...

  7. Liquid-liquid extraction/headspace/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene, (o-, m- and p-)xylene and styrene in olive oil using surfactant-coated carbon nanotubes as extractant.

    PubMed

    Carrillo-Carrión, Carolina; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel

    2007-11-09

    BTEX-S compounds are widely distributed in the environment and can be present in different foodstuffs, including olive oil. Taking into account the risks of the exposure to these compounds, analytical methods for their determination in different matrices are mandatory. In this paper, the use of surfactant-coated multiwalled carbon nanotubes as additive in liquid-liquid extraction is applied for the determination of single-ring aromatic compounds in olive oil samples. After sample treatment, the aqueous extracts are subsequently analyzed by headspace/gas chromatography/mass spectrometry allowing the determination of BTEX-S within ca. 15 min. Each stage of the proposed LLE/HS/GC/MS configuration involves a selectivity enhancement avoiding the interference of other compounds of the sample matrix. Limits of detection were in the range 0.25 ng mL(-1) (obtained for ethylbenzene) and 0.43 ng mL(-1) (for benzene). The repeatability of the proposed method expressed as RSD varied between 1.9% (styrene) and 3.3% (benzene) (n=11).

  8. Development of an analytical method coupling cell membrane chromatography with gas chromatography-mass spectrometry via microextraction by packed sorbent and its application in the screening of volatile active compounds in natural products.

    PubMed

    Li, Miao; Wang, Sicen; He, Langchong

    2015-01-01

    Natural products (NPs) are important sources of lead compounds in modern drug discovery. To facilitate the screening of volatile active compounds in NPs, we have developed a new biochromatography method that uses rat vascular smooth muscle cells (VSMC), which are rich in L-type calcium channels (LCC), to prepare the stationary phase. This integrated method, which couples cell membrane chromatography (CMC) with gas chromatography-mass spectrometry (GC-MS) via microextraction by packed sorbent (MEPS) technology, has been termed VSMC/CMC-MEPS-GC-MS. Methodological validation confirmed its specificity, reliability and convenience. Screening results for Radix Angelicae Dahuricae and Fructus Cnidii obtained using VSMC/CMC-MEPS-GC-MS were consistent with those obtained using VSMC/CMC-offline-GC-MS. MEPS connection plays as simplified solid-phase extraction and replaces the uncontrollable evaporation operation in reported offline connections, so our new method is supposed to be more efficient and reliable than the offline ones, especially for compounds that are volatile, thermally unstable or difficult to purify. In application, senkyunolide A and ligustilide were preliminary identified as the volatile active components in Rhizoma Chuanxiong. We have thus confirmed the suitability of VSMC/CMC-MEPS-GC-MS for volatile active compounds screening in NP. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Composition, mosquito larvicidal, biting deterrent and antifungal activity of essential oils of different plant parts of Cupressus arizonica var. glabra (Carolina Sapphire)

    USDA-ARS?s Scientific Manuscript database

    Essential oils obtained from the hydrodistillation of female cones (FC), male cones (MC), needles-twigs (NT) and wood barks (WB) of ‘Carolina Sapphire’ [Cupressus arizonica var glabra (Sudw.) Little] were analyzed simultaneously by gas chromatography (GC) and gas chromatography–mass spectrometry (GC...

  10. Forensic Drug Identification, Confirmation, and Quantification Using Fully Integrated Gas Chromatography with Fourier Transform Infrared and Mass Spectrometric Detection (GC-FT-IR-MS).

    PubMed

    Lanzarotta, Adam; Lorenz, Lisa; Voelker, Sarah; Falconer, Travis M; Batson, JaCinta S

    2018-05-01

    This manuscript is a continuation of a recent study that described the use of fully integrated gas chromatography with direct deposition Fourier transform infrared detection and mass spectrometric detection (GC-FT-IR-MS) to identify and confirm the presence of sibutramine and AB-FUBINACA. The purpose of the current study was to employ the GC-FT-IR portion of the same instrument to quantify these compounds, thereby demonstrating the ability to identify, confirm, and quantify drug substances using a single GC-FT-IR-MS unit. The performance of the instrument was evaluated by comparing quantitative analytical figures of merit to those measured using an established, widely employed method for quantifying drug substances, high performance liquid chromatography with ultraviolet detection (HPLC-UV). The results demonstrated that GC-FT-IR was outperformed by HPLC-UV with regard to sensitivity, precision, and linear dynamic range (LDR). However, sibutramine and AB-FUBINACA concentrations measured using GC-FT-IR were not significantly different at the 95% confidence interval compared to those measured using HPLC-UV, which demonstrates promise for using GC-FT-IR as a semi-quantitative tool at the very least. The most significant advantage of GC-FT-IR compared to HPLC-UV is selectivity; a higher level of confidence regarding the identity of the analyte being quantified is achieved using GC-FT-IR. Additional advantages of using a single GC-FT-IR-MS instrument for identification, confirmation, and quantification are efficiency, increased sample throughput, decreased consumption of laboratory resources (solvents, chemicals, consumables, etc.), and thus cost.

  11. Quantification of polychlorinated dibenzo-p-dioxins and dibenzofurans by direct injection of sample extract into the comprehensive multidimensional gas chromatograph/high-resolution time-of-flight mass spectrometer.

    PubMed

    Shunji, Hashimoto; Yoshikatsu, Takazawa; Akihiro, Fushimi; Hiroyasu, Ito; Kiyoshi, Tanabe; Yasuyuki, Shibata; Masa-aki, Ubukata; Akihiko, Kusai; Kazuo, Tanaka; Hideyuki, Otsuka; Katsunori, Anezaki

    2008-01-18

    Polychlorinated dibenzo-p-dioxins and dibenzofurans in crude extracts of fly ash and flue gas from municipal waste incinerators were quantified using a comprehensive multidimensional gas chromatograph (GC x GC) coupled to a high-resolution time-of-flight mass spectrometer (HR-TOFMS). For identification and quantification, we developed our own program to prepare 3D chromatograms of selected mass numbers from the data of the GC x GC/HR-TOFMS. Isolation of all congeners with a TCDD toxic equivalency factor from the other isomers by only one injection was confirmed. The instrumental detection limit of TCDD on the GC x GC/HR-TOFMS was 0.9 pg by the relative calibration method. Quantification of these substances in the crude extracts was achieved by direct injection to the GC x GC/HR-TOFMS. The results agree with the values obtained using a generic gas chromatography/high-resolution mass spectrometry (GC/HRMS) system. It was confirmed that measurement by high-resolution TOFMS and GC x GC effectively reduces interference from other chemicals.

  12. Resolving the smell of wood - identification of odour-active compounds in Scots pine (Pinus sylvestris L.).

    PubMed

    Schreiner, Linda; Bauer, Patrick; Buettner, Andrea

    2018-05-29

    Being one of the most common trees in forests, Pinus sylvestris L. is a frequently used raw material for wood products. Its specific odour is, however, mostly unresolved to date. Accordingly, we investigated Scots pine wood samples grown in Germany for their main odorant composition. We employed dedicated odorant analysis techniques such as gas chromatography-olfactometry (GC-O) and aroma extract dilution analysis (AEDA) and successfully detected 44 odour-active compounds; of these, 39 substances were successfully identified by gas chromatography-mass spectrometry/olfactometry (GC-MS/O) and two-dimensional gas chromatography-mass spectrometry/olfactometry (2D-GC-MS/O). Among the main odorants found were (E,E)-nona-2,4-dienal, vanillin, phenylacetic acid, 3-phenylpropanoic acid, δ-octalactone and α-pinene, all of them having been detected with high flavour dilution factors during GC-O analyses. The majority of the identified odorants were fatty acid degradation products, plus some terpenoic substances and odorous substances resulting from the degradation of lignin. Although some of the detected substances have previously been reported as constituents of wood, 11 substances are reported here for the first time as odour-active compounds in wood, amongst them heptanoic acid, γ-octalactone, δ-nonalactone and (E,Z,Z)-trideca-2,4,7-trienal.

  13. Identification of Aroma-active Compounds in Essential Oil from Uncaria Hook by Gas Chromatography- Mass Spectrometry and Gas Chromatography-Olfactometry.

    PubMed

    Iwasa, Megumi; Nakaya, Satoshi; Maki, Yusuke; Marumoto, Shinsuke; Usami, Atsushi; Miyazawa, Mitsuo

    2015-01-01

    The chemical composition of essential oil extracted from Uncaria Hook ("Chotoko" in Japanese), the branch with curved hook of the herbal medicine Uncaria rhynchophylla has been investigated by GC and GC-MS analyses. Eighty-four compounds, representing 90.8% of the total content was identified in oil obtained from Uncaria Hook. The main components i were (E)-cinnamaldehyde (13.4%), α-copaene (8.0%), methyl eugenol (6.8%), δ-cadinene (5.3%), and curcumene (3.6%). The important key aroma-active compounds in the oil were detected by gas chromatography-olfactometry (GC-O) and aroma extract dilution analysis (AEDA), using the flavor dilution (FD) factor to express the odor potency of each compounds. Furthermore, the odor activity value (OAV) has been used as a measure of the relative contribution of each compound to the aroma of the Uncaria Hook oil. The GC-O and AEDA results showed that α-copaene (FD = 4, OAV = 4376), (E)-linalool oxide (FD = 64, OAV = 9.1), and methyl eugenol (FD = 64, OAV = 29) contributed to the woody and spicy odor of Uncaria Hook oil, whereas furfural (FD = 8, OAV = 4808) contributed to its sweet odor. These results warrant further investigations of the application of essential oil from Uncaria Hook in the phytochemical and medicinal fields.

  14. Development of New Decon Green (registered trademark): A How-To Guide for the Rapid Decontamination of CARC Paint

    DTIC Science & Technology

    2008-09-01

    sodium carbonate, and extracted with 2-mL chloroform. The chloroform layer was analyzed for residual agent by Gas Chromatography /Atomic Emission...agent remaining on the panel. Solutions were analyzed by Gas Chromatography /Flame-Ionization Detector (GC/FID) to determine the amounts of agent...transferred to glass scintillation vials. A 100-µL aliquot of the DEP was diluted with 900-µL chloroform (1:10 dilution) in a Gas Chromatography

  15. Identification of Synthetic Polymers and Copolymers by Analytical Pyrolysis-Gas Chromatography/Mass Spectrometry

    ERIC Educational Resources Information Center

    Kusch, Peter

    2014-01-01

    An experiment for the identification of synthetic polymers and copolymers by analytical pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and performed in the polymer analysis courses for third-year undergraduate students of chemistry with material sciences, and for first-year postgraduate students of polymer sciences. In…

  16. Qualitative Analysis by Gas Chromatography: GC versus the Nose in Formulating Artificial Fruit Flavors.

    ERIC Educational Resources Information Center

    Rasmussen, P. W.

    1984-01-01

    Describes an undergraduate laboratory experiment used to illustrate the use of gas chromatography retention indices for the identification of unknown compounds, specifically for the identification of unknown compounds and for the identification of the volatile compounds responsible for the odor of the banana. Procedures, reference data, and sample…

  17. Characterization of Fish Sauce Aroma Impact Compounds Using GC-MS, SPME-Osme-GCO, and Stevens' Power Law Exponents

    USDA-ARS?s Scientific Manuscript database

    The objectives of this study were to characterize volatile compounds and to determine the characteristic aromas associated with impact compounds in 4 fish sauces using solid-phase micro-extraction, gas chromatography-mass spectrometry, Osme, and gas chromatography olfactometry (SPME-Osme-GCO) couple...

  18. Publications - GMC 427 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 427 Publication Details Title: Gas Chromatography coupled to Tandem Mass Spectrometry (GC/MS Tandem Mass Spectrometry (GC/MS/MS) analyses of cuttings for 16 Arctic Slope wells: Alaska Division of

  19. Complementary stable carbon isotope ratio and amount of substance measurements in sports anti-doping.

    PubMed

    Cawley, Adam T; George, Adrian V

    2012-12-01

    The detection of steroids originating from synthetic precursors against a background of their chemically identical natural analogues has proven to be a significant challenge for doping control laboratories accredited by the World Anti-Doping Agency (WADA). The complementary application of gas chromatography-mass spectrometry (GC-MS) and gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) has been demonstrated to provide specific detection of endogenous steroid misuse for improved anti-doping analysis. Markers of synthetically derived steroids are reviewed on the basis of abnormal urinary excretions and low (13)C content. A combinatorial approach is presented for the interpretation of GC-MS and GC-C-IRMS data in the anti-doping context. This methodology can allow all relevant information concerning an individual's metabolism to be assessed in order to make an informed decision with respect to a doping violation. Copyright © 2012 John Wiley & Sons, Ltd.

  20. Detailed analysis and group-type separation of natural fats and oils using comprehensive two-dimensional gas chromatography.

    PubMed

    Mondello, Luigi; Casilli, Alessandro; Tranchida, Peter Quinto; Dugo, Paola; Dugo, Giovanni

    2003-11-26

    Comprehensive gas chromatography (GC x GC) is an adequate methodology for the separation and identification of very complex samples. It is based on the coupling of two capillary columns that each give a different but substantial contribution to the unprecedented resolving power of this technique. The 2D space chromatograms that derive from GC x GC analysis have great potential for identification. This is due to the fact that the contour plot positions, pinpointed by two retention time coordinates, give characteristic patterns for specific families of compounds that can be mathematically translated. This investigation concerned the application of this principle to fatty acid methyl esters that were grouped on an equal double bond number basis. The ester samples were derived from various lipids and all underwent bidimensional analysis on two sets of columns. Peak attribution was supported by mass spectra, linear retention indices and information reported in the literature.

  1. [Profile-effect on quality control of Houttuynia cordata injection].

    PubMed

    Lu, Hong-mei; Liang, Yi-zeng; Qian, Pin

    2005-12-01

    To find corresponding relationship between the fingerprint of Houttuynia cordata injections from different factories and their effects. Houttuynia cordata injections from six different factories were determined by gas chromatography (GC) and gas chromatography-mass spectra (GC-MS), and GC fingerprints were classified by hierarchical clustering. The anti-inflammatory activity of Houttuynia cordata injections was characterized through the rat pleurisy model induced by carrageenin and the mice ear edema model by dimethylbenzene. The anti-inflammatory effect of the injections from the first class factories on the two model was significant, while those from the second class not. GC-MS analysis result indicated that main effect compounds in Houttuynia cordata injections are methyl n-nonyl ketone, decanoylacetaldehyde, lauryl aldehyde, capryl aldehyde, beta-pinene, beta-linalool, 1-nonanol, 4-terpineol, alpha-terpineol, bornyl acetate, n-decanoic acid and acetic acid, geraniol ester etc. There is corresponding relationship between the fingerprint of Houttuynia cordata injections and effect to a certain extent.

  2. Monitoring of CoS 2 reactions using high-temperature XRD coupled with gas chromatography (GC)

    DOE PAGES

    Rodriguez, Mark A.; Coker, Eric Nicholas; Griego, James J. M.; ...

    2016-04-18

    High-temperature X-ray diffraction with concurrent gas chromatography (GC) was used to study cobalt disulfide cathode pellets disassembled from thermal batteries. When CoS 2 cathode materials were analyzed in an air environment, oxidation of the K(Br, Cl) salt phase in the cathode led to the formation of K 2SO 4 that subsequently reacted with the pyrite-type CoS 2 phase leading to cathode decomposition between ~260 and 450 °C. Here, independent thermal analysis experiments, i.e. simultaneous thermogravimetric analysis/differential scanning calorimetry/mass spectrometry (MS), augmented the diffraction results and support the overall picture of CoS 2 decomposition. Both gas analysis measurements (i.e. GC andmore » MS) from the independent experiments confirmed the formation of SO 2 off-gas species during breakdown of the CoS 2. In contrast, characterization of the same cathode material under inert conditions showed the presence of CoS 2 throughout the entire temperature range of analysis.« less

  3. Direct Measurement of Trace Elemental Mercury in Hydrocarbon Matrices by Gas Chromatography with Ultraviolet Photometric Detection.

    PubMed

    Gras, Ronda; Luong, Jim; Shellie, Robert A

    2015-11-17

    We introduce a technique for the direct measurement of elemental mercury in light hydrocarbons such as natural gas. We determined elemental mercury at the parts-per-trillion level with high precision [<3% RSD (n = 20 manual injection)] using gas chromatography with ultraviolet photometric detection (GC-UV) at 254 nm. Our approach requires a small sample volume (1 mL) and does not rely on any form of sample preconcentration. The GC-UV separation employs an inert divinylbenzene porous layer open tubular column set to separate mercury from other components in the sample matrix. We incorporated a 10-port gas-sampling valve in the GC-UV system, which enables automated sampling, as well as back flushing capability to enhance system cleanliness and sample throughput. Total analysis time is <2 min, and the procedure is linear over a range of 2-83 μg/m(3) [correlation coefficient of R(2) = 0.998] with a measured recovery of >98% over this range.

  4. Characterization of three agave species by gas chromatography and solid-phase microextraction-gas chromatography-mass spectrometry.

    PubMed

    Peña-Alvarez, Araceli; Díaz, Laura; Medina, Alejandra; Labastida, Carmen; Capella, Santiago; Vera, Luz Elena

    2004-02-20

    Steam distillation (SD) extraction-solid-phase microextraction coupled to GC-MS was developed for the determination of terpenes and Bligh-Dyer extraction-derivatization coupled with GC for the determination of fatty acids such as ethyl esters were used. It was found that the three different Agave species have the same profile of fatty acids; the quantity of these compounds is different in each Agave variety. On the other hand, different terpenes were identified in the three Agave plants studied: nine in A. salmiana, eight in A. angustifolia and 32 in A. tequilana Weber var. azul.

  5. Trace analysis of muramic acid in indoor air using an automated derivatization instrument and GC-MS(2) or GC-MS(3).

    PubMed

    Harley, William M; Kozar, Michael P; Fox, Alvin

    2002-09-01

    An automated derivatization instrument has been developed for the preparation of alditol acetates from bacterial hydrolysates for analysis by gas chromatography-mass spectrometry (GC-MS). The current report demonstrates the utility of the automated instrument for the more demanding task of trace analysis of muramic acid (Mur) in airborne dust using gas chromatography-tandem mass spectrometry (GC-MS(2)). Conditions for efficient derivatization of Mur, vital for trace analysis, are rigorous including lactam and imido group formation under anhydrous conditions. Furthermore, as the detection limit is lowered, possible contamination or carry-over of samples becomes an increasingly greater consideration and must not occur. The instrument meets these criteria and was successfully used for assaying the levels of Mur in laboratory air, which were found to be much lower than in the previous studies of heavily occupied schools and agricultural environments. The potential for GC-MS(3) in further lowering the detection limit was also demonstrated.

  6. FTIR gas chromatographic analysis of perfumes

    NASA Astrophysics Data System (ADS)

    Diederich, H.; Stout, Phillip J.; Hill, Stephen L.; Krishnan, K.

    1992-03-01

    Perfumes, natural or synthetic, are complex mixtures consisting of numerous components. Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) techniques have been extensively utilized for the analysis of perfumes and essential oils. A limited number of perfume samples have also been analyzed by FT-IR gas chromatographic (GC-FTIR) techniques. Most of the latter studies have been performed using the conventional light pipe (LP) based GC-FTIR systems. In recent years, cold-trapping (in a matrix or neat) GC-FTIR systems have become available. The cold-trapping systems are capable of sub-nanogram sensitivities. In this paper, comparison data between the LP and the neat cold-trapping GC- FTIR systems is presented. The neat cold-trapping interface is known as Tracer. The results of GC-FTIR analysis of some commercial perfumes is also presented. For comparison of LP and Tracer GC-FTIR systems, a reference (synthetic) mixture containing 16 major and numerous minor constituents was used. The components of the mixture are the compounds commonly encountered in commercial perfumes. The GC-FTIR spectra of the reference mixture was obtained under identical chromatographic conditions from an LP and a Tracer system. A comparison of the two sets of data thus generated do indeed show the enhanced sensitivity level of the Tracer system. The comparison also shows that some of the major components detected by the Tracer system were absent from the LP data. Closer examination reveals that these compounds undergo thermal decomposition on contact with the hot gold surface that is part of the LP system. GC-FTIR data were obtained for three commercial perfume samples. The major components of these samples could easily be identified by spectra search against a digitized spectral library created using the Tracer data from the reference mixture.

  7. Characterization of Chemical Composition of Pericarpium Citri Reticulatae Volatile Oil by Comprehensive Two-Dimensional Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry.

    PubMed

    Qin, Kunming; Zheng, Lijuan; Cai, Hao; Cao, Gang; Lou, Yajing; Lu, Tulin; Shu, Yachun; Zhou, Wei; Cai, Baochang

    2013-01-01

    Pericarpium Citri Reticulatae (Chenpi in Chinese) has been widely used as an herbal medicine in Korea, China, and Japan. Chenpi extracts are used to treat indigestion and inflammatory syndromes of the respiratory tract such as bronchitis and asthma. This thesis will analyze chemical compositions of Chenpi volatile oil, which was performed by comprehensive two-dimensional gas chromatography with high-resolution time-of-flight mass spectrometry (GC × GC-HR-TOFMS). One hundred and sixty-seven components were tentatively identified, and terpene compounds are the main components of Chenpi volatile oil, a significant larger number than in previous studies. The majority of the eluted compounds, which were identified, were well separated as a result of high-resolution capability of the GC × GC method, which significantly reduces, the coelution. β -Elemene is tentatively qualified by means of GC × GC in tandem with high-resolution TOFMS detection, which plays an important role in enhancing the effects of many anticancer drugs and in reducing the side effects of chemotherapy. This study suggests that GC × GC-HR-TOFMS is suitable for routine characterization of chemical composition of volatile oil in herbal medicines.

  8. Separation and structural characterization of the new synthetic cannabinoid JWH-018 cyclohexyl methyl derivative "NE-CHMIMO" using flash chromatography, GC-MS, IR and NMR spectroscopy.

    PubMed

    Angerer, Verena; Bisel, Philippe; Moosmann, Bjoern; Westphal, Folker; Auwärter, Volker

    2016-09-01

    Synthetic cannabinoids have become an integral part of the drugs of abuse market since many years. The most frequent form of consumption for this class of substances is smoking of herbal mixtures purchased via the Internet. In this article the identification and structure elucidation of a new synthetic cannabinoid, [1-(cyclohexylmethyl)-1H-indol-3-yl](naphthalen-1-yl)methanone, is described. The compound was found along with 5F-ADB in a 'herbal mixture' called 'Jamaican Gold Extreme', which was sent to our laboratory in the context of a suspected intoxication. For isolation of the substance a flash chromatography separation was applied. Structure elucidation was performed using gas chromatography-mass spectrometry (GC-MS), gas chromatography solid-state infrared (GC-sIR) and nuclear magnetic resonance (NMR) analysis. The new compound can be described as the cyclohexyl methyl derivative of the first generation synthetic cannabinoid JWH-018, and the authors suggest to use "NE-CHMIMO" as a semisystematic name. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Direct screening of ground water samples for fuel oxygenates by headspace liquid phase microextraction-gas chromatography.

    PubMed

    Kaykhaii, Massoud; Mirbaloochzahi, Mohammad Reza

    2008-12-01

    The applicability of the headspace liquid phase microextraction and gas chromatography (HS-LPME/GC) for the expeditious and reliable screening of 68 well water samples for selected fuel oxygenates compounds, viz. methyl tertiary-butyl ether (MTBE), tertiary-amyl methyl ether (TAME), ethyl tertiary-butyl ether (ETBE) and n-butyl ethyl ether (n-BEE) has been evaluated. The method used 3 microl of 1:1 benzyl alcohol/1-octanol as extraction solvent, 20 min extraction time with stirring at 1,250 rpm, at 20 degrees C and salt addition of a mixture of 0.3 g ml(-1) sodium sulphate/0.1 g ml(-1) sodium chloride. The enrichment factors of this method were from 171 to 571. Limits of detection were in the range of 77-110 ng l(-1). The relative standard deviations (RSDs) at 0.05, 0.50 and 10.0 mg l(-1) of spiking levels were in the range of 1.28-6.80% with recoveries between 96.2 and 106.0%. Sixty-eight groundwater wells that were located near different gasoline reservoirs in eight largest cities of the Sistan and Balouchestan province were screened by the method. Eight contaminated wells were identified contained MTBE at levels between 0.3 and 1.7 mg l(-1). In all cases, other target analytes were at low concentrations or not detected.

  10. Qualitative and quantitative determination of extractives in heartwood of Scots pine (Pinus sylvestris L.) by gas chromatography.

    PubMed

    Ekeberg, Dag; Flaete, Per-Otto; Eikenes, Morten; Fongen, Monica; Naess-Andresen, Carl Fredrik

    2006-03-24

    A method for quantitative determination of extractives from heartwood of Scots pine (Pinus sylvestris L.) using gas chromatography (GC) with flame ionization detection (FID) was developed. The limit of detection (LOD) was 0.03 mg/g wood and the linear range (r = 0.9994) was up to 10 mg/g with accuracy within +/- 10% and precision of 18% relative standard deviation. The identification of the extractives was performed using gas chromatography combined with mass spectrometry (GC-MS). The yields of extraction by Soxhlet were tested for solid wood, small particles and fine powder. Small particles were chosen for further analysis. This treatment gave good yields of the most important extractives: pinosylvin, pinosylvin monomethyl ether, resin acids and free fatty acids. The method is used to demonstrate the variation of these extractives across stems and differences in north-south direction.

  11. Identification and Quantitation of Potent Odorants in Spearmint Oils.

    PubMed

    Kelley, Lauren E; Cadwallader, Keith R

    2018-03-14

    Potent odorants in Native spearmint, Scotch spearmint, and Macho mint oils were determined by the combined use of gas chromatography-olfactometry (GCO), gas chromatography-mass spectrometry (GC-MS), and aroma extract dilution analysis (AEDA). Of the 85 odorants detected, ( R)-(-)-carvone was the most potent odorant in all three spearmint oils. Additional predominant odorants in all spearmint oils included eugenol, ethyl ( S)-(+)-2-methylbutanoate, ( E)-β-damascenone, and (3 E,5 Z)-1,3,5-undecatriene. Forty-six compounds were quantitated using various methods, including 19 by gas chromatography with flame ionization detection (GC-FID), 20 by stable isotope dilution analysis (SIDA), and 14 by GCO dilution analysis. Concentrations were used to calculate the odor activity values (OAVs) for predominant odorants in the oils. Among the compounds quantitated, those with the highest OAVs were ( R)-(-)-carvone, 1,8-cineole, ( E, Z)-2,6-nonadienal, ( E)-β-damascenone, and (3 E,5 Z)-1,3,5-undecatriene.

  12. Classification of organic aerosol in the atmosphere over Seoul based on chemical group separation using two dimensional gas chromatography-time of flight mass spectrometry (GC×GC TOFMS) data

    NASA Astrophysics Data System (ADS)

    Jeon, S.; Lim, H. B.; Choi, N.; Lee, J.; Ahn, Y. K.; Kim, Y. P.

    2016-12-01

    Organic aerosols contain thousands of organic compounds and contribute to 20-90% of the total fine aerosol mass. For analyzing organic aerosols, a wide range of analytical techniques have been used such as gas chromatography mass spectrometer (GC/MS), liquid chromatography mass spectrometer (LC/MS), aerosol mass spectrometer (AMS), etc. Among them, comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometer (GCxGC/TOF-MS) can provide higher chemical resolution than AMS and analyze more mass fractions of organic aerosols than GC/MS. In this study, we suggest a new data processing method using GCxGC/TOF-MS data for analyzing organic compounds in the ambient aerosols. TSP samples were collected on the roof of the Asan engineering building, Ewha Womans University, Seoul, South Korea (37.56 °N, 126.94 °E, 20 m above ground level). A total of 67 samples were obtained during summer (August 2013) and winter (January and February 2014) with a PUF sampler (Tisch, TE-1000) on quartz fiber filter. Filters were extracted using accelerated solvent extractor with a mixture of dichloromethane and methanol (3:1, v/v). Total extracts were blown down to 0.5 mL using a nitrogen evaporator (Turbo Vap Ⅱ, caliper Life Sciences). Organic compounds in the TSP samples were separated into 6 chemical groups, depending on their retention time in two dimensions for their volatility and polarity. All area of peaks in each group was summed and variance of total area in each group was compared depending on season and diurnal cycle.

  13. Targeted analyte deconvolution and identification by four-way parallel factor analysis using three-dimensional gas chromatography with mass spectrometry data.

    PubMed

    Watson, Nathanial E; Prebihalo, Sarah E; Synovec, Robert E

    2017-08-29

    Comprehensive three-dimensional gas chromatography with time-of-flight mass spectrometry (GC 3 -TOFMS) creates an opportunity to explore a new paradigm in chemometric analysis. Using this newly described instrument and the well understood Parallel Factor Analysis (PARAFAC) model we present one option for utilization of the novel GC 3 -TOFMS data structure. We present a method which builds upon previous work in both GC 3 and targeted analysis using PARAFAC to simplify some of the implementation challenges previously discovered. Conceptualizing the GC 3 -TOFMS instead as a one-dimensional gas chromatograph with GC × GC-TOFMS detection we allow the instrument to create the PARAFAC target window natively. Each first dimension modulation thus creates a full GC × GC-TOFMS chromatogram fully amenable to PARAFAC. A simple mixture of 115 compounds and a diesel sample are interrogated through this methodology. All test analyte targets are successfully identified in both mixtures. In addition, mass spectral matching of the PARAFAC loadings to library spectra yielded results greater than 900 in 40 of 42 test analyte cases. Twenty-nine of these cases produced match values greater than 950. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Qualitative and quantitative analysis of pyrolysis oil by gas chromatography with flame ionization detection and comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry.

    PubMed

    Sfetsas, Themistoklis; Michailof, Chrysa; Lappas, Angelos; Li, Qiangyi; Kneale, Brian

    2011-05-27

    Pyrolysis oils have attracted a lot of interest, as they are liquid energy carriers and general sources of chemicals. In this work, gas chromatography with flame ionization detector (GC-FID) and two-dimensional gas chromatography with time-of-flight mass spectrometry (GC×GC-TOFMS) techniques were used to provide both qualitative and quantitative results of the analysis of three different pyrolysis oils. The chromatographic methods and parameters were optimized and solvent choice and separation restrictions are discussed. Pyrolysis oil samples were diluted in suitable organic solvent and were analyzed by GC×GC-TOFMS. An average of 300 compounds were detected and identified in all three samples using the ChromaToF (Leco) software. The deconvoluted spectra were compared with the NIST software library for correct matching. Group type classification was performed by use of the ChromaToF software. The quantification of 11 selected compounds was performed by means of a multiple-point external calibration curve. Afterwards, the pyrolysis oils were extracted with water, and the aqueous phase was analyzed both by GC-FID and, after proper change of solvent, by GC×GC-TOFMS. As previously, the selected compounds were quantified by both techniques, by means of multiple point external calibration curves. The parameters of the calibration curves were calculated by weighted linear regression analysis. The limit of detection, limit of quantitation and linearity range for each standard compound with each method are presented. The potency of GC×GC-TOFMS for an efficient mapping of the pyrolysis oil is undisputable, and the possibility of using it for quantification as well has been demonstrated. On the other hand, the GC-FID analysis provides reliable results that allow for a rapid screening of the pyrolysis oil. To the best of our knowledge, very few papers have been reported with quantification attempts on pyrolysis oil samples using GC×GC-TOFMS most of which make use of the internal standard method. This work provides the ground for further analysis of pyrolysis oils of diverse sources for a rational design of both their production and utilization process. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. A gas chromatography-mass spectrometry (GC-MS) method for the detection and quantitation of monofluoroacetate in plants toxic to livestock

    USDA-ARS?s Scientific Manuscript database

    Monofluoroacetate (MFA) is a potent toxin that occurs in over 50 plant species in Africa, Australia, and South America and is responsible for significant livestock deaths in these regions. A gas chromatography–mass spectrometry (GC-MS) method for the analysis of MFA in plants based on the derivatiza...

  16. A gas chromatography-mass spectrometry (GC-MS) method for the detection and quantitation of monofluoroacetate in plants toxic to livestock

    USDA-ARS?s Scientific Manuscript database

    Monofluoroacetate (MFA) is a potent toxin that occurs in over 50 plant species in Africa, Australia, and South America and is responsible for significant livestock deaths in these regions. A gas chromatography–mass spectrometry (GC-MS) method for the analysis of MFA in plants based on the derivatiz...

  17. Elucidating Environmental Fingerprinting Mechanisms of Unconventional Gas Development through Hydrocarbon Analysis.

    PubMed

    Piotrowski, Paulina K; Weggler, Benedikt A; Yoxtheimer, David A; Kelly, Christina N; Barth-Naftilan, Erica; Saiers, James E; Dorman, Frank L

    2018-04-17

    Hydraulic fracturing is an increasingly common technique for the extraction of natural gas entrapped in shale formations. This technique has been highly criticized due to the possibility of environmental contamination, underscoring the need for method development to identify chemical factors that could be utilized in point-source identification of environmental contamination events. Here, we utilize comprehensive two-dimensional gas chromatography (GC × GC) coupled to high-resolution time-of-flight (HRT) mass spectrometry, which offers a unique instrumental combination allowing for petroleomics hydrocarbon fingerprinting. Four flowback fluids from Marcellus shale gas wells in geographic proximity were analyzed for differentiating factors that could be exploited in environmental forensics investigations of shale gas impacts. Kendrick mass defect (KMD) plots of these flowback fluids illustrated well-to-well differences in heteroatomic substituted hydrocarbons, while GC × GC separations showed variance in cyclic hydrocarbons and polyaromatic hydrocarbons among the four wells. Additionally, generating plots that combine GC × GC separation with KMD established a novel data-rich visualization technique that further differentiated the samples.

  18. Occurrence of furan in coffee from Spanish market: Contribution of brewing and roasting.

    PubMed

    Altaki, M S; Santos, F J; Galceran, M T

    2011-06-15

    In this work, we evaluated the occurrence of furan in brews obtained from regular, decaffeinated, and instant coffee and commercial packed capsules. For this purpose, a previously developed automated headspace solid-phase microextraction method coupled to gas chromatography-mass spectrometry (HS-SPME-GC-MS) was used. Initially, the influence of HS-SPME conditions on furan formation was evaluated. In addition, the effect of roasting conditions (temperature and time) used for coffee beans on furan formation was also studied. We found that low temperature and long roasting time (140°C and 20min) decreases the final furan content. Furan concentrations in regular ground coffee brews from an espresso coffee machine were higher (43-146ng/ml) than those obtained from a home drip coffee maker (20 and 78ng/ml), while decaffeinated coffee brews from a home drip coffee maker (14-65ng/ml) showed a furan concentration similar to that obtained from regular coffee. Relatively low concentrations of this compound (12-35ng/ml) were found in instant coffee brews, while commercial packed coffee capsules showed the highest concentrations (117-244ng/ml). Finally, the daily intake of furan through coffee consumption in Barcelona (Spain) (0.03-0.38μg/kg of body weight) was estimated. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Feature selection and recognition from nonspecific volatile profiles for discrimination of apple juices according to variety and geographical origin.

    PubMed

    Guo, Jing; Yue, Tianli; Yuan, Yahong

    2012-10-01

    Apple juice is a complex mixture of volatile and nonvolatile components. To develop discrimination models on the basis of the volatile composition for an efficient classification of apple juices according to apple variety and geographical origin, chromatography volatile profiles of 50 apple juice samples belonging to 6 varieties and from 5 counties of Shaanxi (China) were obtained by headspace solid-phase microextraction coupled with gas chromatography. The volatile profiles were processed as continuous and nonspecific signals through multivariate analysis techniques. Different preprocessing methods were applied to raw chromatographic data. The blind chemometric analysis of the preprocessed chromatographic profiles was carried out. Stepwise linear discriminant analysis (SLDA) revealed satisfactory discriminations of apple juices according to variety and geographical origin, provided respectively 100% and 89.8% success rate in terms of prediction ability. Finally, the discriminant volatile compounds selected by SLDA were identified by gas chromatography-mass spectrometry. The proposed strategy was able to verify the variety and geographical origin of apple juices involving only a reduced number of discriminate retention times selected by the stepwise procedure. This result encourages the similar procedures to be considered in quality control of apple juices. This work presented a method for an efficient discrimination of apple juices according to apple variety and geographical origin using HS-SPME-GC-MS together with chemometric tools. Discrimination models developed could help to achieve greater control over the quality of the juice and to detect possible adulteration of the product. © 2012 Institute of Food Technologists®

  20. Evaluation of gas chromatography-tandem quadrupole mass spectrometry for the determination of organochlorine pesticides in fats and oils.

    PubMed

    Patel, Katan; Fussell, Richard J; Hetmanski, Mike; Goodall, David M; Keely, Brendan J

    2005-03-18

    A gas chromatography-tandem quadrupole mass spectrometry multi-residue method for the analysis of 19 organochlorine pesticides in fats and oils has been developed. Gel permeation chromatography was employed to remove lipid material prior to GC-MS/MS analysis. Average recoveries of the pesticides spiked at 10 and 50 microg kg(-1) into fish oil, pork fat, olive oil and hydrogenated vegetable oil were typically in the range 70-110% with relative standard deviations generally less than 10%. Calculated limits of detection are between 0.1 and 2.0 microg kg(-1) and results obtained for the analysis of proficiency test materials are in good agreement with assigned values. The higher selectivity of the GC-MS/MS compared to electron capture detection and GC-MS in selective ion monitoring mode allowed unambiguous identification and confirmation of all the target pesticides at low microg kg(-1) levels in fats and oils in a single analysis.

  1. Quantitation of Phenol Levels in Oil of Wintergreen Using Gas Chromatography-Mass Spectrometry with Selected Ion Monitoring

    ERIC Educational Resources Information Center

    Sobel, Robert M.; Ballantine, David S.; Ryzhov, Victor

    2005-01-01

    Industrial application of gas chromatography-mass spectrometry (GC-MS) analysis is a powerful technique that could be used to elucidate components of a complex mixture while offering the benefits of high-precision quantitative analysis. The natural wintergreen oil is examined for its phenol concentration to determine the level of refining…

  2. DETECTION OF HIGH MOLECULAR WEIGHT ORGANIC TRACERS IN VEGETATION SMOKE SAMPLES BY HIGH-TEMPERATURE GAS CHROMATOGRAPHY-MASS SPECTROMETRY. (R823990)

    EPA Science Inventory

    High-temperature high-resolution gas chromatography
    (HTGC) is an established technique for the separation of
    complex mixtures of high molecular weight (HMW) compounds
    which do not elute when analyzed on conventional GC
    columns. The combination of this technique wit...

  3. DETERMINATION OF A BOUND MUSK XYLENE METABOLITE IN CARP HEMOGLOBIN AS A BIOMARKER OF EXPOSURE BY GAS CHROMATOGRAPHY MASS SPECTROMETRY USING SELECTED ION MONITORING

    EPA Science Inventory

    Musk xylene (MX) is widely used as a fragrance ingredient in commercial toiletries. Identification and quantification of a bound 4-amino-MX (AMX) metabolite was carried out by gas chromatography-mass spectrometry (GC/MS), with selected ion monitoring (SIM). Detection of AMX occur...

  4. Odor and odorous chemical emissions from dairy and swine facilities: Part 5-Simultaneous chemical and sensory analysis with Gas Chromatography - Mass Spectrometry - Olfactometry

    USDA-ARS?s Scientific Manuscript database

    Simultaneous chemical and sensory analyses using gas chromatography-mass spectrometry-olfactometry (GC-MS-O) for air samples collected at barn exhaust fans were used for quantification and ranking of odor impact of target odorous gases. Fifteen target odorous VOCs (odorants) were selected. Air sampl...

  5. THE DETERMINATION OF NON-PESTICIDAL AND PESTICIDAL ORGANOTIN COMPOUNDS IN WATER BY GAS CHROMATOGRAPHY WITH [PULSED] FLAME PHOTOMETRIC DETECTION (GS/PFPD): THE EFFECTS OF "MASS" DISCRIMINATION

    EPA Science Inventory

    Capillary gas chromatography with GC/PFPD was used in the development of analytical methodology for determining both non-pesticidal and pesticidal organotin compounds in drinking water and other aqueous matrices. The method involves aqueous ethylation of organotin analytes with ...

  6. A NEW SW-846 METHOD FOR THE ANALYSIS OF TOXAPHENE AND TOXAPHENE CONGENERS IN SOLID AND AQUEOUS SAMPLES USING GAS CHROMATOGRAPHY / NEGATIVE ION MASS SPECTROMETRY

    EPA Science Inventory

    US EPA SW-846 methods have typically relied on dual column gas chromatography coupled with electron capture detection (GC-ECD) for analysis of low concentrations of organochlorine pesticides, including toxaphene, in environmental samples. Toxaphene is one of the most widely appl...

  7. A GC-MS method for the detection of toluene and ethylbenzene in volatile substance abuse.

    PubMed

    El-Haj, B M; Al-Amri, A M; Hassan, M H; Bin-Khadem, R K; Al-Hadi, A A

    2000-09-01

    The interference of some substances with the gas chromatography-flame ionization detection and gas chromatography-Fourier transform infrared detection of toluene and ethylbenzene in volatile substance abuse poses problems. A gas chromatography-mass spectrometry (GC-MS) method that will overcome such interference has been developed for the detection of toluene and/or ethylbenzene in the headspace of preparations and products containing these substances and in the headspace of blood samples in the cases of volatile substance abuse. The method is based on converting toluene to benzoic acid via the formation of benzotrichloride. The latter compound was obtained upon the reaction of toluene with chlorine gas under direct sunlight conditions. In the presence of water, benzotrichloride was converted to benzoic acid. Ethylbenzene was converted to benzoic acid and two phenylethanols via the formation of side chain chloro-substituted phenylethanes followed by reaction with water. The chloro-substituted phenylethanes were obtained by the reaction of ethylbenzene with chlorine under direct sunlight conditions. The benzoic acid resulting from toluene and/or ethylbenzene and the two phenylethanols resulting from ethylbenzene were detected by GC-MS as their trimethylsilyl (TMS) derivatives. For the method to be viable for the detection of volatile substance abuse, the chlorination reactions were effected in the gaseous state.

  8. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    PubMed

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  9. The catalytic activity of CoMo/USY on deoxygenation reaction of anisole in a batch reactor

    NASA Astrophysics Data System (ADS)

    Nugrahaningtyas, K. D.; Putri, I. F.; Heraldy, E.; Hidayat, Y.

    2018-04-01

    The catalytic hydrodeoxigenation of the bio oil model compounds (biomass pyrolysis results) typically uses sulphide catalysts. In this study, we studied the activity of non-sulphide catalyst, the effect of temperature and reaction time on anisole deoxygenation. The catalytic activity was performed in a batch reactor, using N2 gas at 1 bar of pressure. The product was analyzed by gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). The result showed that the Co-Mo/USY catalyst perform a highest activity and produce pentamethylbenzene, an oxygen free products, when reaction time is 2 hours. The Co-Mo/USY catalysts has the value of the total yield of the product increased with time increase drastically.

  10. Development of a simple and sensitive method for the characterization of odorous waste gas emissions by means of solid-phase microextraction (SPME) and GC-MS/olfactometry.

    PubMed

    Kleeberg, K K; Liu, Y; Jans, M; Schlegelmilch, M; Streese, J; Stegmann, R

    2005-01-01

    A solid-phase microextraction (SPME) method has been developed for the extraction of odorous compounds from waste gas. The enriched compounds were characterized by gas chromatography-mass spectrometry (GC-MS) and gas chromatography followed by simultaneous flame ionization detection and olfactometry (GC-FID/O). Five different SPME fiber coatings were tested, and the carboxen/polydimethylsiloxane (CAR/PDMS) fiber showed the highest ability to extract odorous compounds from the waste gas. Furthermore, parameters such as exposure time, desorption temperature, and desorption time have been optimized. The SPME method was successfully used to characterize an odorous waste gas from a fat refinery prior to and after waste gas treatment in order to describe the treatment efficiency of the used laboratory scale plant which consisted of a bioscrubber/biofilter combination and an activated carbon adsorber. The developed method is a valuable approach to provide detailed information of waste gas composition and complements existing methods for the determination of odors. However, caution should be exercised if CAR/PDMS fibers are used for the quantification of odorous compounds in multi-component matrices like waste gas emissions since the relative affinity of each analyte was shown to differ according to the total amount of analytes present in the sample.

  11. Gas and liquid chromatography with inductively coupled plasma mass spectrometry detection for environmental speciation analysis — advances and limitations

    NASA Astrophysics Data System (ADS)

    Szpunar, Joanna; McSheehy, Shona; Połeć, Kasia; Vacchina, Véronique; Mounicou, Sandra; Rodriguez, Isaac; Łobiński, Ryszard

    2000-07-01

    Recent advances in the coupling of gas chromatography (GC) and high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP MS) and their role in trace element speciation analysis of environmental materials are presented. The discussion is illustrated with three research examples concerning the following topics: (i) development and coupling of multicapillary microcolumn GC with ICP MS for speciation of organotin in sediment and biological tissue samples; (ii) speciation of arsenic in marine algae by size-exclusion-anion-exchange HPLC-ICP MS; and (iii) speciation of cadmium in plant cell cultures by size-exclusion HPLC-ICP MS. Particular attention is paid to the problem of signal identification in ICP MS chromatograms; the potential of electrospray MS/MS for this purpose is highlighted.

  12. pH-dependent equilibrium isotope fractionation associated with the compound specific nitrogen and carbon isotope analysis of substituted anilines by SPME-GC/IRMS.

    PubMed

    Skarpeli-Liati, Marita; Turgeon, Aurora; Garr, Ashley N; Arnold, William A; Cramer, Christopher J; Hofstetter, Thomas B

    2011-03-01

    Solid-phase microextraction (SPME) coupled to gas chromatography/isotope ratio mass spectrometry (GC/IRMS) was used to elucidate the effects of N-atom protonation on the analysis of N and C isotope signatures of selected aromatic amines. Precise and accurate isotope ratios were measured using polydimethylsiloxane/divinylbenzene (PDMS/DVB) as the SPME fiber material at solution pH-values that exceeded the pK(a) of the substituted aniline's conjugate acid by two pH-units. Deviations of δ(15)N and δ(13)C-values from reference measurements by elemental analyzer IRMS were small (<0.9‰) and within the typical uncertainties of isotope ratio measurements by SPME-GC/IRMS. Under these conditions, the detection limits for accurate isotope ratio measurements were between 0.64 and 2.1 mg L(-1) for δ(15)N and between 0.13 and 0.54 mg L(-1) for δ(13)C, respectively. Substantial inverse N isotope fractionation was observed by SPME-GC/IRMS as the fraction of protonated species increased with decreasing pH leading to deviations of -20‰ while the corresponding δ(13)C-values were largely invariant. From isotope ratio analysis at different solution pHs and theoretical calculations by density functional theory, we derived equilibrium isotope effects, EIEs, pertinent to aromatic amine protonation of 0.980 and 1.001 for N and C, respectively, which were very similar for all compounds investigated. Our work shows that N-atom protonation can compromise accurate compound-specific N isotope analysis of aromatic amines.

  13. Evaluation of volatile metabolites as markers in Lycopersicon esculentum L. cultivars discrimination by multivariate analysis of headspace solid phase microextraction and mass spectrometry data.

    PubMed

    Figueira, José; Câmara, Hugo; Pereira, Jorge; Câmara, José S

    2014-02-15

    To gain insights on the effects of cultivar on the volatile metabolomic expression of different tomato (Lycopersicon esculentum L.) cultivars--Plum, Campari, Grape, Cherry and Regional, cultivated under similar edafoclimatic conditions, and to identify the most discriminate volatile marker metabolites related to the cultivar, the chromatographic profiles resulting from headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-qMS) analysis, combined with multivariate analysis were investigated. The data set composed by the 77 volatile metabolites identified in the target tomato cultivars, 5 of which (2,2,6-trimethylcyclohexanone, 2-methyl-6-methyleneoctan-2-ol, 4-octadecyl-morpholine, (Z)-methyl-3-hexenoate and 3-octanone) are reported for the first time in tomato volatile metabolomic composition, was evaluated by chemometrics. Firstly, principal component analysis was carried out in order to visualise data trends and clusters, and then, linear discriminant analysis in order to detect the set of volatile metabolites able to differentiate groups according to tomato cultivars. The results obtained revealed a perfect discrimination between the different Lycopersicon esculentum L. cultivars considered. The assignment success rate was 100% in classification and 80% in prediction ability by using "leave-one-out" cross-validation procedure. The volatile profile was able to differentiate all five cultivars and revealed complex interactions between them including the participation in the same biosynthetic pathway. The volatile metabolomic platform for tomato samples obtained by HS-SPME/GC-qMS here described, and the interrelationship detected among the volatile metabolites can be used as a roadmap for biotechnological applications, namely to improve tomato aroma and their acceptance in the final consumer, and for traceability studies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Determination of lysine content based on an in situ pretreatment and headspace gas chromatographic measurement technique.

    PubMed

    Wan, Xiao-Fang; Liu, Bao-Lian; Yu, Teng; Yan, Ning; Chai, Xin-Sheng; Li, You-Ming; Chen, Guang-Xue

    2018-05-01

    This work reports on a simple method for the determination of lysine content by an in situ sample pretreatment and headspace gas chromatographic measurement (HS-GC) technique, based on carbon dioxide (CO 2 ) formation from the pretreatment reaction (between lysine and ninhydrin solution) in a closed vial. It was observed that complete lysine conversion to CO 2 could be achieved within 60 min at 60 °C in a phosphate buffer medium (pH = 4.0), with a minimum molar ratio of ninhydrin/lysine of 16. The results showed that the method had a good precision (RSD < 5.23%) and accuracy (within 6.80%), compared to the results measured by a reference method (ninhydrin spectroscopic method). Due to the feature of in situ sample pretreatment and headspace measurement, the present method becomes very simple and particularly suitable to be used for batch sample analysis in lysine-related research and applications. Graphical abstract The flow path of the reaction and HS-GC measurement for the lysine analysis.

  15. Sudden death caused by 1,1-difluoroethane inhalation.

    PubMed

    Xiong, Zhenggang; Avella, Joseph; Wetli, Charles V

    2004-05-01

    A 20-year-old man was found dead on the floor next to a computer, with a nearly full can of "CRC Duster" dust remover located next to the deceased on the floor, and an empty can of the same product on the computer desk. Toxicologic evaluation using either gas chromatography/mass spectrometry (GC/MS) or gas chromatography/flame ionization detector (GC/FID) method identified the active ingredient 1,1-difluoroethane (Freon 152a) in all tissues analyzed. Tissue distribution studies revealed highest concentration in central blood, lung, and liver. It is believed that the 1,1-difluoroethane inhalation was the cause of death.

  16. A simple and sensitive quantitation of N,N-dimethyltryptamine by gas chromatography with surface ionization detection.

    PubMed

    Ishii, A; Seno, H; Suzuki, O; Hattori, H; Kumazawa, T

    1997-01-01

    A simple and sensitive method for determination of N,N-dimethyltryptamine (DMT) by gas chromatography (GC) with surface ionization detection (SID) is presented. Whole blood or urine, containing DMT and gramine (internal standard), was subjected to solid-phase extraction with a Sep-Pak C18 cartridge before analysis by GC-SID. The calibration curve was linear in the DMT range of 1.25-20 ng/mL blood or urine. The detection limit of DMT was about 0.5 ng/mL (10 pg on-column). The recovery of both DMT and gramine spiked in biological fluids was above 86%.

  17. Rapid and easy identification of Illicium verum Hook. f. and its adulterant Illicium anisatum Linn. by fluorescent microscopy and gas chromatography.

    PubMed

    Joshi, Vaishali C; Srinivas, Pullela V; Khan, Ikhlas A

    2005-01-01

    Illicium verum Hook. f. is used as an herbal tea to treat colic pain in infants. Reports suggest that Star anise herbal tea may be adulterated with Illicium anisatum Linn. A short and rapid method using microscopy and gas chromatography (GC) was developed to detect I. anisatum Linn., an adulterant in the powdered mixture of I. verum. Anatomical differences in the epicarp cells of I. verum and I. anisatum fruits were clearly defined as examined under fluorescent microscopy and scanning electron microscopy. A GC method was developed for quick identification of possible I. anisatum adulteration with I. verum.

  18. Investigating the coffee flavour in South African Pinotage wine using novel offline olfactometry and comprehensive gas chromatography with time of flight mass spectrometry.

    PubMed

    Naudé, Yvette; Rohwer, Egmont R

    2013-01-04

    Pinotage wine from several South African wine cellars has been produced with a novel coffee flavour. We have investigated this innovative coffee effect using in house developed solventless sampling and fractionating olfactometric techniques, which are unique in their ability to study synergistic aroma effects as opposed to traditional gas chromatography olfactometry (GC-O) which is designed to, ideally, evaluate single eluting compounds in a chromatographic sequence. Sections of the chromatogram, multiple or single peaks, were recaptured on multichannel open tubular silicone rubber (polydimethylsiloxane (PDMS)) traps at the end of a GC column. The recaptured fractions were released in a controlled manner for offline olfactory evaluation, and for qualitative analysis using comprehensive gas chromatography coupled to time of flight mass spectrometry (GC×GC-TOFMS) for compound separation and identification, thus permitting correlation of odour with specific compounds. A combination of furfural and 2-furanmethanol was responsible for a roast coffee bean-like odour in coffee style Pinotage wines. This coffee perception is the result of a synergistic effect in which no individual compound was responsible for the characteristic aroma. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Impact of processing on odour-active compounds of a mixed tomato-onion puree.

    PubMed

    Koutidou, Maria; Grauwet, Tara; Van Loey, Ann; Acharya, Parag

    2017-08-01

    Gas chromatography-olfactometry revealed thirty-two odour-active compounds in a heat-processed tomato-onion puree, among which twenty-seven were identified by gas chromatography-olfactometry-mass spectrometry (GC-O-MS) and comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC×GC-TOF MS). Based on the results of two olfactometric methods, i.e. detection frequency and aroma extract dilution analysis, the most potent aroma components include: dipropyl disulfide, S-propyl thioacetate, dimethyl trisulfide, 1-octen-3-one, methional, dipropyl trisulfide, 4,5-dimethylthiazole, 2-phenylacetaldehyde and sotolone. Processing of mixed vegetable systems can add complexity in their aroma profiles due to (bio)chemical interactions between the components. Therefore, the impact of different processing steps (i.e. thermal blanching, all-in-one and split-stream processes) on the volatile profile and aroma of a mixed tomato-onion puree has been investigated using a GC-MS fingerprinting approach. Results showed the potential to control the aroma in a mixed tomato-onion system through process-induced enzymatic modulations for producing tomato-onion food products with distinct aroma characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Contribution to aroma characteristics of mutton process flavor from the enzymatic hydrolysate of sheep bone protein assessed by descriptive sensory analysis and gas chromatography olfactometry.

    PubMed

    Zhan, Ping; Tian, Honglei; Zhang, Xiaoming; Wang, Liping

    2013-03-15

    Changes in the aroma characteristics of mutton process flavors (MPFs) prepared from sheep bone protein hydrolysates (SBPHs) with different degrees of hydrolysis (DH) were evaluated using gas chromatography-mass spectrometry (GC-MS), gas chromatography-olfactometry (GC-O), and descriptive sensory analysis (DSA). Five attributes (muttony, meaty, roasted, mouthful, and simulate) were selected to assess MPFs. The results of DSA showed a distinct difference among the control sample MPF0 and other MPF samples with added SBPHs for different DHs of almost all sensory attributes. MPF5 (DH 25.92%) was the strongest in the muttony, meaty, and roasted attributes, whereas MPF6 (DH 30.89%) was the strongest in the simulate and roasted attributes. Thirty-six compounds were identified as odor-active compounds for the evaluation of the sensory characteristics of MPFs via GC-MS-O analysis. The results of correlation analysis among odor-active compounds, molecular weight, and DSA further confirmed that the SBPH with a DH range of 25.92-30.89% may be a desirable precursor for the sensory characteristics of MPF. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Characterisation of biodegradation capacities of environmental microflorae for diesel oil by comprehensive two-dimensional gas chromatography.

    PubMed

    Penet, Sophie; Vendeuvre, Colombe; Bertoncini, Fabrice; Marchal, Rémy; Monot, Frédéric

    2006-12-01

    In contaminated soils, efficiency of natural attenuation or engineered bioremediation largely depends on biodegradation capacities of the local microflorae. In the present study, the biodegradation capacities of various microflorae towards diesel oil were determined in laboratory conditions. Microflorae were collected from 9 contaminated and 10 uncontaminated soil samples and were compared to urban wastewater activated sludge. The recalcitrance of hydrocarbons in tests was characterised using both gas chromatography (GC) and comprehensive two-dimensional gas chromatography (GCxGC). The microflorae from contaminated soils were found to exhibit higher degradation capacities than those from uncontaminated soil and activated sludge. In cultures inoculated by contaminated-soil microflorae, 80% of diesel oil on an average was consumed over 4-week incubation compared to only 64% in uncontaminated soil and 60% in activated sludge cultures. As shown by GC, n-alkanes of diesel oil were totally utilised by each microflora but differentiated degradation extents were observed for cyclic and branched hydrocarbons. The enhanced degradation capacities of impacted-soil microflorae resulted probably from an adaptation to the hydrocarbon contaminants but a similar adaptation was noted in uncontaminated soils when conifer trees might have released natural hydrocarbons. GCxGC showed that a contaminated-soil microflora removed all aromatics and all branched alkanes containing less than C(15). The most recalcitrant compounds were the branched and cyclic alkanes with 15-23 atoms of carbon.

  2. Identification and deconvolution of carbohydrates with gas chromatography-vacuum ultraviolet spectroscopy.

    PubMed

    Schenk, Jamie; Nagy, Gabe; Pohl, Nicola L B; Leghissa, Allegra; Smuts, Jonathan; Schug, Kevin A

    2017-09-01

    Methodology for qualitative and quantitative determination of carbohydrates with gas chromatography coupled to vacuum ultraviolet detection (GC-VUV) is presented. Saccharides have been intently studied and are commonly analyzed by gas chromatography-mass spectrometry (GC-MS), but not always effectively. This can be attributed to their high degree of structural complexity: α/β anomers from their axial/equatorial hydroxyl group positioning at the C1-OH and flexible ring structures that lead to the open chain, five-membered ring furanose, and six-membered ring pyranose configurations. This complexity can result in convoluted chromatograms, ambiguous fragmentation patterns and, ultimately, analyte misidentification. In this study, mono-, di, and tri-saccharides were derivatized by two different methods-permethylation and oximation/pertrimethylsilylation-and analyzed by GC-VUV. These two derivatization methods were then compared for their efficiency, ease of use, and robustness. Permethylation proved to be a useful technique for the analysis of ketopentoses and pharmaceuticals soluble in dimethyl sulfoxide (DMSO), while the oximation/pertrimethylsilylation method prevailed as the more promising, overall, derivatization method. VUV spectra have been shown to be distinct and allow for efficient differentiation of isomeric species such as ketopentoses and reducing versus non-reducing sugars. In addition to identification, pharmaceutical samples containing several compounds were derivatized and analyzed for their sugar content with the GC-VUV technique to provide data for qualitative analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Analysis of trichothecene mycotoxins in contaminated grains by gas chromatography/matrix isolation/Fourier transform infrared spectroscopy and gas chromatography/mass spectrometry.

    PubMed

    Mossoba, M M; Adams, S; Roach, J A; Trucksess, M W

    1996-01-01

    Gas chromatography/matrix isolation/Fourier transform infrared (GC/MI/FTIR) spectroscopy and GC/mass spectrometry (MS) were used to confirm the identities of trimethylsilyl (TMS) derivatives of trichothecene mycotoxins in naturally contaminated grains. Infrared spectral bands observed in the fingerprint region were unique for 10 trichothecene standards. Characteristic absorption bands were observed for the ester (near 1750 cm-1) and ketone (near 1700 cm-1) carbonyl stretching vibrations, the acetate CH3 symmetric bend (1370 cm-1), the epoxide ring (1262 cm-1), the trimethylsilyl CH3 in-plane deformation (1253 cm-1), the ester (O)C-O asymmetric stretching vibration (near 1244 cm-1), and several other bands including intense features due to the TMS function. Infrared bands observed under cryogenic matrix isolation conditions were compared with those found at room temperature in a potassium bromide matrix for 5 of these standards. Identities of deoxynivalenol (DON) from barley and mixed feed, nivalenol from wheat and barley, and DON and fusarenon-x from sweet corn were confirmed by comparison of their infrared spectral bands with those of standards. The identity of DON in the same test samples of sweet corn was confirmed further by GC/MS. GC/MS was also used to quantitate the levels of DON (67-455 ppm) in sweet corn test samples.

  4. VOLATILE ORGANO-METALLOIDS IN BIO-SOLID MATERIALS: ANALYSIS BY VACUUM DISTILLATION-GC/MS

    EPA Science Inventory

    An analytical method based on vacuum distillation-gas chromatography-mass spectrometry (VD-GC-MS)

    was developed for determining volatile organo-metalloid contaminants in bio-solid materials. Method

    performance was evaluated for dimethylselenide (DMSe), dimethyldisel...

  5. Environmental assessment of a crude-oil heater using staged air lances for NOx reduction. Volume 1. Technical results. Final report June 1981-November 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRosier, R.

    1984-07-01

    This volume of the report gives emission results from field tests of a crude-oil process heater burning a combination of oil and refinery gas. The heater had been modified by adding a system for injecting secondary air to reduce NOx emissions. One test was conducted with the staged air system (low NOx), and the other, without (baseline). Tests included continuous monitoring of flue gas emissions and source assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of the samples utilizing gas chromatography (GC), infrared spectrometry (IR), gas chromatography/mass spectroscopy (GC/MS), and low resolution mass spectrometry (SSMS)more » for trace metals. LRMS analysis suggested the presence of eight compound categories in the organic emissions during the baseline test and four in the low-NOx test.« less

  6. Gas chromatography coupled to tunable pulsed glow discharge time-of-flight mass spectrometry for environmental analysis.

    PubMed

    Solà-Vázquez, Auristela; Lara-Gonzalo, Azucena; Costa-Fernández, José M; Pereiro, Rosario; Sanz-Medel, Alfredo

    2010-05-01

    A tuneable microsecond pulsed direct current glow discharge (GD)-time-of-flight mass spectrometer MS(TOF) developed in our laboratory was coupled to a gas chromatograph (GC) to obtain sequential collection of the mass spectra, at different temporal regimes occurring in the GD pulses, during elution of the analytes. The capabilities of this set-up were explored using a mixture of volatile organic compounds of environmental concern: BrClCH, Cl(3)CH, Cl(4)C, BrCl(2)CH, Br(2)ClCH, Br(3)CH. The experimental parameters of the GC-pulsed GD-MS(TOF) prototype were optimized in order to separate appropriately and analyze the six selected organic compounds, and two GC carrier gases, helium and nitrogen, were evaluated. Mass spectra for all analytes were obtained in the prepeak, plateau and afterpeak temporal regimes of the pulsed GD. Results showed that helium offered the best elemental sensitivity, while nitrogen provided higher signal intensities for fragments and molecular peaks. The analytical performance characteristics were also worked out for each analyte. Absolute detection limits obtained were in the order of ng. In a second step, headspace solid phase microextraction (HS SPME), as sample preparation and preconcentration technique, was evaluated for the quantification of the compounds under study, in order to achieve the required analytical sensitivity for trihalomethanes European Union (EU) environmental legislation. The analytical figures of merit obtained using the proposed methodology showed rather good detection limits (between 2 and 13 microg L(-1) depending on the analyte). In fact, the developed methodology met the EU legislation requirements (the maximum level permitted in tap water for the "total trihalomethanes" is set at 100 microg L(-1)). Real analysis of drinking water and river water were successfully carried out. To our knowledge this is the first application of GC-pulsed GD-MS(TOF) for the analysis of real samples. Its ability to provide elemental, fragments and molecular information of the organic compounds is demonstrated.

  7. Multidimensional and comprehensive two-dimensional gas chromatography of dichloromethane soluble products from a high sulfur Jordanian oil shale.

    PubMed

    Amer, Mohammad W; Mitrevski, Blagoj; Jackson, W Roy; Chaffee, Alan L; Marriott, Philip J

    2014-03-01

    A high sulfur Jordanian oil shale was converted into liquid hydrocarbons by reaction at 390 °C under N2, and the dichloromethane soluble fraction of the products was isolated then analyzed by using gas chromatography (GC). Comprehensive two-dimensional GC (GC×GC) and multidimensional GC (MDGC) were applied for component separation on a polar - non-polar column set. Flame-ionization detection (FID) was used with GC×GC for general sample profiling, and mass spectrometry (MS) for component identification in MDGC. Multidimensional GC revealed a range of thiophenes (th), benzothiophenes (bth) and small amounts of dibenzothiophenes (dbth) and benzonaphthothiophenes (bnth). In addition, a range of aliphatic alkanes and cycloalkanes, ethers, polar single ring aromatic compounds and small amounts of polycyclic aromatics were also identified. Some of these compound classes were not uniquely observable by conventional 1D GC, and certainly this is true for many of their minor constituent members. The total number of distinct compounds was very large (ca.>1000). GC×GC was shown to be appropriate for general sample profiling, and MDGC-MS proved to be a powerful technique for the separation and identification of sulfur-containing components and other polar compounds. © 2013 Published by Elsevier B.V.

  8. [Determination and prediction for vapor pressures of organophosphate flame retardants by gas chromatography].

    PubMed

    Wang, Qingzhi; Zhao, Hongxia; Wang, Yan; Xie, Qing; Chen, Jingwen; Quan, Xie

    2017-09-08

    Organophosphate flame retardants (OPFRs) are ubiquitous in the environment. To better understand and predict their environmental transport and fate, well-defined physicochemical properties are required. Vapor pressures ( P ) of 14 OPFRs were estimated as a function of temperature ( T ) by gas chromatography (GC), while 1,1,1-trichioro-2,2-bis (4-chlorophenyl) ethane ( p,p '-DDT) was acted as a reference substance. Their log P GC values and internal energies of phase transfer (△ vap H ) ranged from -6.17 to -1.25 and 74.1 kJ/mol to 122 kJ/mol, respectively. Substitution pattern and molar volume ( V M ) were found to be capable of influencing log P GC values of the OPFRs. The halogenated alkyl-OPFRs had lower log P GC values than aryl-or alkyl-OPFRs. The bigger the molar volume was, the smaller the log P GC value was. In addition, a quantitative structure-property relationship (QSPR) model of log P GC versus different relative retention times (RRTs) was developed with a high cross-validated value ( Q 2 cum ) of 0.946, indicating a good predictive ability and stability. Therefore, the log P GC values of the OPFRs without standard substance can be predicted by using their RRTs on different GC columns.

  9. Achieving high peak capacity production for gas chromatography and comprehensive two-dimensional gas chromatography by minimizing off-column peak broadening.

    PubMed

    Wilson, Ryan B; Siegler, W Christopher; Hoggard, Jamin C; Fitz, Brian D; Nadeau, Jeremy S; Synovec, Robert E

    2011-05-27

    By taking into consideration band broadening theory and using those results to select experimental conditions, and also by reducing the injection pulse width, peak capacity production (i.e., peak capacity per separation time) is substantially improved for one dimensional (1D-GC) and comprehensive two dimensional (GC×GC) gas chromatography. A theoretical framework for determining the optimal linear gas velocity (the linear gas velocity producing the minimum H), from experimental parameters provides an in-depth understanding of the potential for GC separations in the absence of extra-column band broadening. The extra-column band broadening is referred to herein as off-column band broadening since it is additional band broadening not due to the on-column separation processes. The theory provides the basis to experimentally evaluate and improve temperature programmed 1D-GC separations, but in order to do so with a commercial 1D-GC instrument platform, off-column band broadening from injection and detection needed to be significantly reduced. Specifically for injection, a resistively heated transfer line is coupled to a high-speed diaphragm valve to provide a suitable injection pulse width (referred to herein as modified injection). Additionally, flame ionization detection (FID) was modified to provide a data collection rate of 5kHz. The use of long, relatively narrow open tubular capillary columns and a 40°C/min programming rate were explored for 1D-GC, specifically a 40m, 180μm i.d. capillary column operated at or above the optimal average linear gas velocity. Injection using standard auto-injection with a 1:400 split resulted in an average peak width of ∼1.5s, hence a peak capacity production of 40peaks/min. In contrast, use of modified injection produced ∼500ms peak widths for 1D-GC, i.e., a peak capacity production of 120peaks/min (a 3-fold improvement over standard auto-injection). Implementation of modified injection resulted in retention time, peak width, peak height, and peak area average RSD%'s of 0.006, 0.8, 3.4, and 4.0%, respectively. Modified injection onto the first column of a GC×GC coupled with another high-speed valve injection onto the second column produced an instrument with high peak capacity production (500-800peaks/min), ∼5-fold to 8-fold higher than typically reported for GC×GC. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Analysis of Whiskey by Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography/Mass Spectrometry: An Upper Division Analytical Chemistry Experiment Guided by Green Chemistry

    ERIC Educational Resources Information Center

    Owens, Janel E.; Zimmerman, Laura B.; Gardner, Michael A.; Lowe, Luis E.

    2016-01-01

    Analysis of whiskey samples prepared by a green microextraction technique, dispersive liquid-liquid microextraction (DLLME), before analysis by a qualitative gas chromatography-mass spectrometry (GC/MS) method, is described as a laboratory experiment for an upper division instrumental methods of analysis laboratory course. Here, aroma compounds in…

  11. Thermal Desorption Capability Development for Enhanced On-site Health Risk Assessment: HAPSITE (registered trademark) ER Passive Sampling in the Field

    DTIC Science & Technology

    2015-06-07

    Field-Portable Gas Chromatograph-Mass Spectrometer.” Forensic Toxicol, 2006, 24, 17-22. Smith, P. “Person-Portable Gas Chromatography : Rapid Temperature...bench-top Gas Chromatograph-Mass Spectrometer (GC-MS) system (ISQ). Nine sites were sampled and analyzed for compounds using Environmental Protection...extraction methods for Liquid Chromatography -MS (LC- MS). Additionally, TD is approximately 1000X more sensitive, requires minimal sample preparation

  12. Simultaneous determination of dissolved gases and moisture in mineral insulating oils by static headspace gas chromatography with helium photoionization pulsed discharge detection.

    PubMed

    Jalbert, J; Gilbert, R; Tétreault, P

    2001-07-15

    This paper presents the development of a static headspace capillary gas chromatographic method (HS-GC) for simultaneously determining dissolved gases (H2, O2, N2, CO, CO2, CH4, C2H6, C2H4, C2H2, C3H8) and moisture from a unique 15-mL mineral oil sample. A headspace sampler device is used to equilibrate the sample species in a two-phase system under controlled temperature and agitation conditions. A portion of the equilibrated species is then automatically split-injected into two chromatographic channels mounted on the same GC for their separation. The hydrocarbons and the lighter gases are separated on the first channel by a GS-Q column coupled with a MolSieve 5-A column via a bypass valve, while the moisture is separated on the second channel using a Stabilwax column. The analytes are detected by using two universal pulsed-discharge helium ionization detectors (PDHID). The performance of the method was established using equilibrated vials containing known amounts of gas mixture, water, and blank oil. The signal is linear over the concentration ranges normally found for samples collected from open-breathing power transformers. Determination sensitivity varies with the nature of the species considered with values as high as 21 500 A x 10(-9) s (microg/ g)(-1) for H2O, 46-216 A x 10(-9) s (microL/L)(-1) for the hydrocarbons and carbon oxides, and as low as 8-21 A x 10(-9) s (microL/L)(-1) for the O2 and N2 permanent gases. The detection limit of the method is between 0.08 and 6 microL/L for the dissolved gases, except for O2, N2, and CO2, where higher values are observed due to air intrusion during sampler operations, and 0.1 microg/g for the dissolved water. Ten consecutive measurements in the low and high levels of the calibration curves have shown a precision better than 12% and 6%, respectively, in all cases. A comparison study between the HS-GC method and the ASTM standard procedures on 31 field samples showed a very good agreement of the results. The advantages of configuring the arrangement with two PDHID over the conventional flame ionization and thermal conductivity detectors were clearly demonstrated.

  13. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Hok, S; Alcaraz, A

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limitmore » of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.« less

  14. Combined thin layer chromatography and gas chromatography with mass spectrometric analysis of lipid classes and fatty acids in malnourished polar bears (Ursus maritimus) which swam to Iceland.

    PubMed

    Eibler, Dorothee; Krüger, Sabine; Skírnisson, Karl; Vetter, Walter

    2017-03-01

    Between 2008 and 2011, four polar bears (Ursus maritimus) from the Greenland population swam and/or drifted on ice to Iceland where they arrived in very poor body condition. Body fat resources in these animals were only between 0% and 10% of the body weight (usually 25%). Here we studied the lipid composition in different tissues (adipose tissue if available, liver, kidney and muscle). Lipid classes were determined by thin layer chromatography (TLC) and on-column gas chromatography with mass spectrometry (GC/MS). The fatty acid pattern of total lipids and free fatty acids was analyzed by GC/MS in selected ion monitoring (SIM) mode. Additionally, cholesteryl esters and native fatty acid methyl esters, initially detected as zones in thin layer chromatograms, were enriched by solid phase extraction and quantified by GC/MS. The ratio of free fatty acids to native fatty acid methyl esters could be correlated with the remained body lipids in the polar bears and thus may also serve as a marker for other starving animals or even for humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Oxybuprocaine and five metabolites simultaneously determined in urine by gas chromatography and gas chromatography-mass spectrometry after extraction with Extrelut.

    PubMed

    Kasuya, F; Igarashi, K; Fukui, M

    1987-05-01

    We describe a gas-liquid chromatographic (GC) method for determination of oxybuprocaine, and a gas chromatographic-mass spectrometric (GC-MS) method for simultaneous determination of four of its nine metabolites in urine. We used an Extrelut column to simply and rapidly extract oxybuprocaine and its metabolites from urine. For the GC-MS analyses, we monitored the characteristic fragment ions at m/z 353, 395, 369, 411, and 235 for 3-butoxy-4-aminobenzoic acid (metabolite 2, M-2), 3-butoxy-4-acetylaminobenzoic acid (M-3), 3-hydroxy-4-aminobenzoic acid (M-4), 3-hydroxy-4-acetylaminobenzoic acid (M-5), and methaqualone (internal standard), respectively. We quantified the glucuronide of M-2 after enzymic treatment. The assay's selectivity and reproducibility (within-day and between-day CVs less than 8% for all metabolites) make it applicable to determine oxybuprocaine and its metabolites in human urine. Mean 9-h urinary excretion of oxybuprocaine and its five metabolites from four healthy volunteers was 89.2% after a 100-mg oral dose.

  16. Gas Chromatography-Tandem Mass Spectrometry of Lignin Pyrolyzates with Dopant-Assisted Atmospheric Pressure Chemical Ionization and Molecular Structure Search with CSI:FingerID

    NASA Astrophysics Data System (ADS)

    Larson, Evan A.; Hutchinson, Carolyn P.; Lee, Young Jin

    2018-06-01

    Dopant-assisted atmospheric pressure chemical ionization (dAPCI) is a soft ionization method rarely used for gas chromatography-mass spectrometry (GC-MS). The current study combines GC-dAPCI with tandem mass spectrometry (MS/MS) for analysis of a complex mixture such as lignin pyrolysis analysis. To identify the structures of volatile lignin pyrolysis products, collision-induced dissociation (CID) MS/MS using a quadrupole time-of-flight mass spectrometer (QTOFMS) and pseudo MS/MS through in-source collision-induced dissociation (ISCID) using a single stage TOFMS are utilized. To overcome the lack of MS/MS database, Compound Structure Identification (CSI):FingerID is used to interpret CID spectra and predict best matched structures from PubChem library. With this approach, a total of 59 compounds were positively identified in comparison to only 22 in NIST database search of GC-EI-MS dataset. This study demonstrates the effectiveness of GC-dAPCI-MS/MS to overcome the limitations of traditional GC-EI-MS analysis when EI-MS database is not sufficient. [Figure not available: see fulltext.

  17. Inquiry-Based Arson Investigation for General Chemistry Using GC-MS

    ERIC Educational Resources Information Center

    Maurer, Marta K.; Bukowski, Michael R.; Menachery, Mary D.; Zatorsky, Adam R.

    2010-01-01

    We have developed a two-week guided-inquiry laboratory in which first-semester general chemistry students investigate a suspected arson using gas chromatography--mass spectrometry and paper chromatography. In the process of evaluating evidence from the crime scene, students develop and test hypotheses and learn the fundamentals of chromatography,…

  18. Evaluation of the quality of sandalwood essential oils by gas chromatography-mass spectrometry.

    PubMed

    Howes, Melanie-Jayne R; Simmonds, Monique S J; Kite, Geoffrey C

    2004-03-05

    Trade and historic oils from 'sandalwoods', labelled as Amyris balsamifera, Eremophila mitchelli, Fusanus acuminatus (= Santalum acuminatum), Santalum album, S. austrocaledonicum, S. latifolium, S. spicatum and S. yasi, were assessed using gas chromatography-mass spectrometry (GC-MS). Using GC-MS, none of the oils assessed complied with the internationally recognised standard of a 90% santalol content, and only about half of the trade sandalwood oils met with recent International Organisation for Standardisation standards. The majority of trade oils, reportedly from S. album, contained approximately 50-70% santalols (Z-alpha and Z-beta). Thus, the internationally recognised specification (90% santalols) for S. album requires re-evaluation by more efficient analysis methods. In view of the issues associated with the quality of sandalwood oils being traded, specifications of > or = 43% Z-alpha-santalol and > or = 18% Z-beta-santalol for S. album oil estimated by GC-MS are suggested. GC-MS are recommended as it assists with authentication and quality control issues associated with sandalwood oils.

  19. Development and Applications of Portable Gas Chromatography-Mass Spectrometry for Emergency Responders, the Military, and Law-Enforcement Organizations.

    PubMed

    Leary, Pauline E; Dobson, Gareth S; Reffner, John A

    2016-05-01

    Portable gas chromatography-mass spectrometry (GC-MS) systems are being deployed for field use, and are designed with this goal in mind. Performance characteristics of instruments that are successful in the field are different from those of equivalent technologies that are successful in a laboratory setting. These field-portable systems are extending the capabilities of the field user, providing investigative leads and confirmatory identifications in real time. Many different types of users benefit from the availability of this technology including emergency responders, the military, and law-enforcement organizations. This manuscript describes performance characteristics that are important for field-portable instruments, especially field-portable GC-MS systems, and demonstrates the value of this equipment to the disciplines of explosives investigations, fire investigations, and counterfeit-drug detection. This paper describes the current state of portable GC-MS technology, including a review of the development of portable GC-MS, as well as a demonstration of the value of this capability using different examples. © The Author(s) 2016.

  20. Analysis of volatiles in fire debris by combination of activated charcoal strips (ACS) and automated thermal desorption-gas chromatography-mass spectrometry (ATD/GC-MS).

    PubMed

    Martin Fabritius, Marie; Broillet, Alain; König, Stefan; Weinmann, Wolfgang

    2018-06-04

    Adsorption of volatiles in gaseous phase to activated charcoal strip (ACS) is one possibility for the extraction and concentration of ignitable liquid residues (ILRs) from fire debris in arson investigations. Besides liquid extraction using carbon dioxide or hexane, automated thermo-desorption can be used to transfer adsorbed residues to direct analysis by gas chromatography-mass spectrometry (GC-MS). We present a fire debris analysis work-flow with headspace adsorption of volatiles onto ACS and subsequent automated thermo-desorption (ATD) GC-MS analysis. Only a small portion of the ACS is inserted in the ATD tube for thermal desorption coupled to GC-MS, allowing for subsequent confirmation analysis with another portion of the same ACS. This approach is a promising alternative to the routinely used ACS method with solvent extraction of retained volatiles, and the application to fire debris analysis is demonstrated. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Extraction and characterization of montmorency (Prunus cerasus L.) sour cherry pit oil

    USDA-ARS?s Scientific Manuscript database

    Montmorency sour cherry (Prunus cerasus L.) pit oil was extracted and characterized by various methods including: gas chromatography (GC), liquid chromatography coupled with mass spectrometry (LC-MS), nuclear magnetic resonance (NMR), thermogravimetric analysis (TGA), differential scanning calorime...

  2. Quantitative and enantioselective analysis of monoterpenes from plant chambers and in ambient air using SPME

    NASA Astrophysics Data System (ADS)

    Yassaa, N.; Custer, T.; Song, W.; Pech, F.; Kesselmeier, J.; Williams, J.

    2010-08-01

    A solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) system has been developed for quantifying enantiomeric and nonenantiomeric monoterpenes in plant chamber studies and ambient air. Performance of this system was checked using a capillary diffusion system to produce monoterpene standards. The adsorption efficiency, competitive adsorption and chromatographic peak resolution of monoterpene enantiomer pairs were compared for three SPME fibre coatings: 75 μm Carboxen-PDMS (CAR-PDMS), 50/30 μm, divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and 65 μm divinylbenzene-polydimethyl-siloxane (DVB-PDMS). Key parameters such as the linearity and reproducibility of the SPME system have been investigated in this work. The best compromise between the enantiomeric separation of monoterpenes and competitive adsorption of the isoprenoids on the solid SPME fibre coating was found for DVB-PDMS fibres. The optimum conditions using DVB-PDMS fibres were applied to measure the exchange rates of monoterpenes in the emission of Quercus ilex using a laboratory whole plant enclosure under light and dark conditions, as well as in ambient air. With 592 and 223 ng m-2 s-1, respectively, β-myrcene and limonene were the predominant monoterpenes in the emission of Q. ilex. These values were closely comparable to those obtained using a zNose and cartridge GC-FID systems.

  3. Quantitative and enantioselective analysis of monoterpenes from plant chambers and in ambient air using SPME

    NASA Astrophysics Data System (ADS)

    Yassaa, N.; Custer, T.; Song, W.; Pech, F.; Kesselmeier, J.; Williams, J.

    2010-11-01

    A headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) system has been developed for quantifying enantiomeric and nonenantiomeric monoterpenes in plant chamber studies and ambient air. Performance of this system was checked using a capillary diffusion system to produce monoterpene standards. The adsorption efficiency, competitive adsorption and chromatographic peak resolution of monoterpene enantiomer pairs were compared for three SPME fibre coatings: 75 μm Carboxen-PDMS (CAR-PDMS), 50/30 μm divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and 65 μm divinylbenzene-polydimethylsiloxane (DVB-PDMS). Key parameters such as the linearity and reproducibility of the SPME system have been investigated in this work. The best compromise between the enantiomeric separation of monoterpenes and competitive adsorption of the isoprenoids on the solid SPME fibre coating was found for DVB-PDMS fibres. The optimum conditions using DVB-PDMS fibres were applied to measure the exchange rates of monoterpenes in the emission of Quercus ilex using a laboratory whole plant enclosure under light and dark conditions, as well as in ambient air. With 592 and 223 ng m-2 s-1 respectively, β-myrcene and limonene were the predominant monoterpenes in the emission of Q. ilex. These values were closely comparable to those obtained using a zNose and cartridge GC-FID systems.

  4. Study of flavour compounds from orange juices by HS-SPME and GC-MS

    NASA Astrophysics Data System (ADS)

    Schmutzer, G.; Avram, V.; Covaciu, F.; Feher, I.; Magdas, A.; David, L.; Moldovan, Z.

    2013-11-01

    The flavour of the orange juices, which gives the taste and odour of the product, is an important criterion about the products quality for consumers. A fresh single strength and two commercial orange juices (obtained from concentrate) flavour profile were studied using a selective and sensitive gas chromatography - mass spectrometry (GC-MS) analytical system, after a solvent free, single step preconcentration and extraction technique, the headspace solid phase microextraction (HP-SPME). In the studied orange juices 55 flavour compounds were detected and classified as belonging to the esters, alcohols, ketones, monoterpenes and sesquiterpenes chemical families. The fresh single strength orange juice was characterized by high amount of esters, monoterpenes and sesquiterpenes. Limonene and valencene were the most abundant flavours in this fresh natural orange juice. Alcohols and ketones were found in higher concentration in the commercial orange juices made from concentrate, than in the single strength products. Nevertheless, in commercial juices the most abundant flavour was limonene and α-terpineol. The results highlight clear differences between fresh singles strength orange juice and juice from concentrate. The orange juices reconstructed from concentrate, made in Romania, present low quantity of flavour compounds, suggesting the absence or a low rearomatization process, but extraneous components were not detected.

  5. Headspace Solid-Phase Microextraction and Ultrasonic Extraction with the Solvent Sequences in Chemical Profiling of Allium ursinum L. Honey.

    PubMed

    Jerković, Igor; Kuś, Piotr M

    2017-11-06

    A volatile profile of ramson (wild garlic, Allium ursinum L.) honey was investigated by headspace solid-phase microextraction (HS-SPME) and ultrasonic solvent extraction (USE) followed by gas chromatography and mass spectrometry (GC-FID/GC-MS) analyses. The headspace was dominated by linalool derivatives: cis - and trans -linalool oxides (25.3%; 9.2%), hotrienol (12.7%), and linalool (5.8%). Besides direct extraction with dichloromethane and pentane/diethyl ether mixture (1:2, v / v ), two solvent sequences (I: pentane → diethyl ether; II: pentane → pentane/diethyl ether (1:2, v / v ) → dichloromethane) were applied. Striking differences were noted among the obtained chemical profiles. The extracts with diethyl ether contained hydroquinone (25.8-36.8%) and 4-hydroxybenzoic acid (11.6-16.6%) as the major compounds, while ( E )-4-(r-1',t-2',c-4'-trihydroxy-2',6',6'-trimethylcyclohexyl)but-3-en-2-one predominated in dichloromethane extracts (18.3-49.1%). Therefore, combination of different solvents was crucial for the comprehensive investigation of volatile organic compounds in this honey type. This particular magastigmane was previously reported only in thymus honey and hydroquinone in vipers bugloss honey, while a combination of the mentioned predominant compounds is unique for A. ursinum honey.

  6. Headspace and direct immersion solid phase microextraction procedures for selenite determination in urine, saliva and milk by gas chromatography mass spectrometry.

    PubMed

    Kapsimali, D C; Zachariadis, G A

    2009-10-01

    Two solid phase microextraction modes were investigated and compared for their performance on the determination of selenites in various biological liquids like human urine and saliva and various types of milk. Using sodium tetraethylborate (NaBEt(4)) as ethylating reagent, selenites are converted in situ to volatile diethylselenides (DESe) in aqueous medium. The derivative is collected in situ by solid phase microextraction (SPME) using a silica fiber coated with poly(dimethylsiloxane) (PDMS) either from the headspace (HS-SPME) or directly from the liquid phase (LP-SPME) and finally determined by capillary GC/MS. Under optimum conditions of SPME, the GC separation was also optimized. Between the two examined microextraction techniques, direct immersion of the PDMS fiber in the liquid phase was proved less satisfactory. In contrast, the headspace procedure appears to be more efficient. The quantification of selenites was achieved in SIM mode with good analytical performance. A non-fat milk powder certified reference material was analyzed to evaluate the accuracy of the method. The overall precision of the method was ranged between 6.2% and 9.7%. Detection limits achieved were 0.05microgL(-1) for human urine, 0.08microgL(-1) for saliva and 0.03-0.06microgL(-1) in various milk matrices.

  7. Sampling methods for the study of volatile profile of PDO wine vinegars. A comparison using multivariate data analysis.

    PubMed

    Ríos-Reina, Rocío; Morales, M Lourdes; García-González, Diego L; Amigo, José M; Callejón, Raquel M

    2018-03-01

    High-quality wine vinegars have been registered in Spain under protected designation of origin (PDO): "Vinagre de Jerez", "Vinagre de Condado de Huelva" and "Vinagre de Montilla-Moriles". The raw material, production and aging processes determine their quality and their aromatic composition. Vinegar volatile profile is usually analyzed by gas chromatography-mass spectrometry (GC-MS), being necessary a previous extraction step. Thus, three different sampling methods (Headspace solid phase microextraction "HS-SPME", Headspace stir bar sorptive extraction "HSSE" and Dynamic headspace extraction "DHS") were studied for the analysis of the volatile composition of Spanish PDO wine vinegars. Multivariate curve resolution (MCR) was used to solve chromatographic problems, improving the results obtained. Principal component analysis (PCA) showed that not all the sampling methods were equally suitable for the characterization and differentiation between PDOs and categories, being HSSE the technique that made able the best vinegar characterization. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Evaluation of Urinary Btex, Nicotine, and Cotinine as Biomarkers of Airborne Pollutants in Nonsmokers and Smokers.

    PubMed

    Brajenović, Nataša; Karačonji, Irena Brčić; Bulog, Aleksandar

    2015-01-01

    Benzene, toluene, ethylbenzene, and isomeric xylenes (BTEX) are by-products of tobacco smoke and traffic emissions. The aim of this study was to determine the contribution of cigarette smoking to urinary levels of BTEX present in humans. Nicotine and cotinine, biomarkers of exposure to tobacco smoke, as well as BTEX, were measured in urine of smokers (n = 70) and nonsmokers (n = 65) using headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). In smokers, a significant correlation was found between urinary BTEX levels and nicotine and cotinine. In addition, significant regression models with nicotine and cotinine as predictors showed that BTEX in smokers' urine was predominantly derived from exposure to tobacco smoke. In nonsmokers a weak correlation between BTEX and nicotine and cotinine was found in urine. Further, there was a lack of significant contribution of BTEX to urinary nicotine and cotinine concentrations in nonsmokers. Thus, it was presumed that vehicle exhaust was the main source of exposure to BTEX in nonsmokers.

  9. Analysis of potassium formate in airport storm water runoff by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Fries, Elke; Klasmeier, Jörg

    2009-01-30

    Potassium formate was extracted from airport storm water runoff by headspace solid-phase microextraction (HS-SPME) and analyzed by GC-MS. Formate was transformed to formic acid by adding phosphoric acid. Subsequently, formic acid was derivatized to methyl formate by adding methanol. Using sodium [(2)H]formate (formate-d) as an internal standard, the relative standard deviation of the peak area ratio of formate (m/z 60) and formate-d (m/z 61) was 0.6% at a concentration of 208.5 mg L(-1). Calibration was linear in the range of 0.5-208.5 mg L(-1). The detection limit calculated considering the blank value was 0.176 mg L(-1). The mean concentration of potassium formate in airport storm water runoff collected after surface de-icing operations was 86.9 mg L(-1) (n=11) with concentrations ranging from 15.1 mg L(-1) to 228.6 mg L(-1).

  10. Recent Advances in Techniques for Starch Esters and the Applications: A Review

    PubMed Central

    Hong, Jing; Zeng, Xin-An; Brennan, Charles S.; Brennan, Margaret; Han, Zhong

    2016-01-01

    Esterification is one of the most important methods to alter the structure of starch granules and improve its applications. Conventionally, starch esters are prepared by conventional or dual modification techniques, which have the disadvantages of being expensive, have regent overdoses, and are time-consuming. In addition, the degree of substitution (DS) is often considered as the primary factor in view of its contribution to estimate substituted groups of starch esters. In order to improve the detection accuracy and production efficiency, different detection techniques, including titration, nuclear magnetic resonance (NMR), Fourier transform infrared spectroscopy (FT-IR), thermal gravimetric analysis/infrared spectroscopy (TGA/IR) and headspace gas chromatography (HS-GC), have been developed for DS. This paper gives a comprehensive overview on the recent advances in DS analysis and starch esterification techniques. Additionally, the advantages, limitations, some perspectives on future trends of these techniques and the applications of their derivatives in the food industry are also presented. PMID:28231145

  11. Occurrence of furan in commercial processed foods in Brazil.

    PubMed

    Arisseto, A P; Vicente, E; Furlani, R P Z; Ueno, M S; Pereira, A L D; Toledo, M C F

    2012-01-01

    Selected commercial processed foods available in the Brazilian market (306 samples) were analysed for furan content using a validated gas chromatography-mass spectrometry method preceded by headspace solid phase micro-extraction (HS-SPME-GC/MS). Canned and jarred foods, including vegetable, meat, fruit and sweet products, showed levels up to 32.8 µg kg⁻¹, with the highest concentrations observed in vegetables and meats. For coffee, furan content ranged from 253.0 to 5021.4 µg kg⁻¹ in the roasted ground coffee and from not detected to 156.6 µg kg⁻¹ in the beverage. For sauces, levels up to 138.1 µg kg⁻¹ were found. In cereal-based products, the highest concentrations (up to 191.3 µg kg⁻¹) were observed in breakfast cereal (corn flakes), cracker (cream crackers) and biscuit (wafer). In general, these results are comparable with those reported in other countries and will be useful for a preliminary estimate of the furan dietary intake in Brazil.

  12. The effect of cryogenic grinding and hammer milling on the flavour quality of ground pepper (Piper nigrum L.).

    PubMed

    Liu, Hong; Zeng, Fankui; Wang, Qinghuang; Ou, Shiyi; Tan, Lehe; Gu, Fenglin

    2013-12-15

    In this study, we compared the effects of cryogenic grinding and hammer milling on the flavour attributes of black, white, and green pepper. The flavour attributes were analysed using headspace solid-phase micro-extraction (HS-SPME) and gas chromatography-mass spectrometry (GC/MS), sensory evaluation and electronic nose (e-nose) analysis. Cryogenic grinding resulted in minimal damage to the colour, flavour, and sensory attributes of the spices. Cryogenic grinding was also better than hammer milling at preserving the main potent aroma constituents, but the concentrations of the main aroma constituents were dramatically reduced after storing the samples at 4 °C for 6 months. Pattern matching performed by the e-nose further supported our sensory and instrumental findings. Overall, cryogenic grinding was superior to hammer milling for preserving the sensory properties and flavour attributes of pepper without significantly affecting its quality. However, we found that the flavour quality of ground pepper was reduced during storage. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Influence of some packaging materials and of natural tocopherols on the sensory properties of breakfast cereals.

    PubMed

    Paradiso, Vito M; Caponio, Francesco; Summo, Carmine; Gomes, Tommaso

    2014-04-01

    The combined effect of natural antioxidants and packaging materials on the quality decay of breakfast cereals during storage was evaluated. Corn flakes were produced on industrial scale, using different packages and adding natural tocopherols to the ingredients, and stored for 1 year. The samples were then submitted to sensory analysis and HS-solid phase microextraction/gas chromatography/mass spectrometry (SPME/GC/MS) analysis. The packaging had a significant influence on the sensory profile of the aged product: metallized polypropylene gave the highest levels of oxidation compounds and sensory defects. The sensory profile was improved using polypropylene and especially high-density polyethylene. Natural tocopherols reduced the sensory decay of the flakes and the oxidative evolution of the volatile profile. They gave the most remarkable improvement in polypropylene (either metallized or not) packs. Polypropylene showed a barrier effect on the scalping of volatiles outside of the pack. This led to higher levels of oxidation volatiles and faster rates of the further oxidative processes involving the volatiles.

  14. Direct thermal desorption in the analysis of cheese volatiles by gas chromatography and gas chromatography-mass spectrometry: comparison with simultaneous distillation-extraction and dynamic headspace.

    PubMed

    Valero, E; Sanz, J; Martínez-Castro, I

    2001-06-01

    Direct thermal desorption (DTD) has been used as a technique for extracting volatile components of cheese as a preliminary step to their gas chromatographic (GC) analysis. In this study, it is applied to different cheese varieties: Camembert, blue, Chaumes, and La Serena. Volatiles are also extracted using other techniques such as simultaneous distillation-extraction and dynamic headspace. Separation and identification of the cheese components are carried out by GC-mass spectrometry. Approximately 100 compounds are detected in the examined cheeses. The described results show that DTD is fast, simple, and easy to automate; requires only a small amount of sample (approximately 50 mg); and affords quantitative information about the main groups of compounds present in cheeses.

  15. Separation of polychlorinated biphenyls by fast gas chromatography.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alvarado, J. S.; Silzer, J.; Lemley, F.

    1997-12-01

    The separation of commercially available polychlorinated biphenyls (PCBs) by fast gas chromatography (fast GC) has been studied. Aroclor 1254 was separated by using two column types: DB-1 and SPB-608. The fast GC used a split-splitless injector to introduce the sample, followed by a cold trap at -90 C to focus the sample. Rapid heating was used to introduce the sample into the short chromatographic column to decrease band broadening. Hydrogen was the carrier gas at velocities of 100 to 125 cm s-1. Analyses were performed by using an electron capture detector (ECD). Separation was achieved with both columns in lessmore » than 6 min. With the greatly shortened run times, reproducibility can be tested quickly and consequently with low cost.« less

  16. The measurement of muscle protein synthesis in broilers with a flooding dose technique: use of 15N-labelled phenylalanine, GC-MS and GC-C-IRMS.

    PubMed

    Dänicke, S; Böttcher, W; Simon, O; Jeroch, H

    2001-01-01

    An experiment was carried out to measure fractional muscle protein synthesis rates (k(s)) in broilers with injection of a flooding dose of phenylalanine (1 ml/100 g body weight of 150 mM phenylalanine; 38 atom percent excess (APE) [15N]phenylalanine). K(s) was calculated from the [15N] enrichment in phenylalanine of tissue-free and protein-bound phenylalanine using both gas chromatography mass spectrometry (GC-MS) and gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) for measurements after a 10 min isotope incorporation period. The tertiary-butyldimethylsilyl (t-BDMS) derivatives of phenylalanine were used for gas chromatographic separation in both systems. GC-MS and GC-C-IRMS were calibrated for a range of 7 to 37 [15N]APE and 0 to 0.62 [15N]APE, respectively, and for sample sizes of 0.45 to 4.5 nmol phenylalanine and 7 to 40 nmol phenylalanine, respectively. Reproducibility of standards as a measure of precision varied from 0.06 to 0.29 [15N]APE and from 0.0004 to 0.0018 [15N]APE in GC-MS and GC-C-IRMS, respectively. K(s) was measured in the m. pectoralis major of broilers fed rye based diets (56%) which were provided either unsupplemented (-) or supplemented (+) with an enzyme preparation containing xylanase. K(s) in breast muscles was significantly increased from 21.8%/d to 23.9%/d due to enzyme supplementation. It can be concluded from the study that the measurement of protein synthesis in broilers with the flooding dose technique can be carried out by using [15N]phenylalanine, GC-MS and GC-C-IRMS.

  17. Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts from urban dust and diesel standard reference materials using a 2D-LC/2D-GC system.

    PubMed

    Ahmed, Trifa M; Lim, Hwanmi; Bergvall, Christoffer; Westerholm, Roger

    2013-10-01

    A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.

  18. The utility of ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) for clinically relevant steroid analysis.

    PubMed

    Storbeck, Karl-Heinz; Gilligan, Lorna; Jenkinson, Carl; Baranowski, Elizabeth S; Quanson, Jonathan L; Arlt, Wiebke; Taylor, Angela E

    2018-05-15

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) assays are considered the reference standard for serum steroid hormone analyses, while full urinary steroid profiles are only achievable by gas chromatography (GC-MS). Both LC-MS/MS and GC-MS have well documented strengths and limitations. Recently, commercial ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) systems have been developed. These systems combine the resolution of GC with the high-throughput capabilities of UHPLC. Uptake of this new technology into research and clinical labs has been slow, possibly due to the perceived increase in complexity. Here we therefore present fundamental principles of UHPSFC-MS/MS and the likely applications for this technology in the clinical research setting, while commenting on potential hurdles based on our experience to date. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Differentiation of Commercial PDO Wines Produced in Istria (Croatia) According to Variety and Harvest Year Based on HS-SPME-GC/MS Volatile Aroma Compound Profiling.

    PubMed

    Lukić, Igor; Horvat, Ivana

    2017-03-01

    To differentiate monovarietal wines made from native and introduced varieties in Istria (Croatia), samples of Malvazija istarska, Chardonnay and Muscat yellow from two harvest years (2013 and 2014) were subjected to headspace solid-phase microextraction and gas chromatographic/mass spectrometric analysis (HS-SPME-GC/MS) of volatile aroma compounds. Significant effects of variety and harvest year were determined, but their interaction complicated the differentiation. Particular compounds were consistent as markers of variety in both years: nerol for Malvazija, ethyl cinnamate and a tentatively identified isomer of dimethylbenzaldehyde for Chardonnay, and terpenes for Muscat yellow. Wines from 2013 contained higher concentrations of the majority of important volatiles. A 100% correct differentiation of Malvazija istarska and Chardonnay wines according to both variety and harvest year was achieved by stepwise linear discriminant analysis.

  20. GC and GC-MS determination of fluoroacetic acid and phenoxy acid herbicides via triphasal extractive pentafluorobenzylation using a polymer-bound phase-transfer catalyst.

    PubMed

    Miki, A; Tsuchihashi, H; Yamashita, M

    1998-01-01

    A simple and sensitive gas chromatography and gas chromatography-mass spectrometry (GC-MS) procedure has been developed for fluoroacetic acid (FA) and phenoxy acid herbicides (PAHs) via triphasal extractive pentafluorobenzylation. The triphasal system consisted of an aqueous sample, the extraction solvent toluene containing pentafluorobenzyl bromide as the derivatization reagent, and polymer-bound tri-n-butyl-methylphosphonium bromide as a phase-transfer catalyst, FA spiked in beverages, such as orange juice and milk, was extracted as its pentafluorobenzyl (PFB) derivative under moderate conditions (i.e., at a pH value of 6.5 at 60 degrees C). The detection limits were 0.10-0.20 microgram/mL by GC with electron-capture detection (GC-ECD), and 0.42-0.50 microgram/mL by full-scan GC-MS. PAHs were also detectable in the same manner within the detection limits of 0.05-0.10 microgram/mL by GC-ECD and 0.13-0.25 microgram/mL by full-scan GC-MS. Urine and serum which both contained 2,4-dichlorophenoxyacetic acid could also be analyzed by GC-MS after the triphasal pentafluorobenzylation. The detection limit was 0.20 microgram/mL in the full-scan mode and 10 ng/mL in the selected ion monitoring mode both for the urine and serum.

  1. A quantification method for peroxyacetyl nitrate (PAN) using gas chromatography (GC) with a non-radioactive pulsed discharge detector (PDD)

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Jaffe, Daniel A.; Gao, Xin; McClure, Crystal D.

    2018-04-01

    In this study, we developed a method for continuous PAN measurements by gas chromatography (GC) with a non-radioactive pulsed discharge detector (PDD). Operational parameters were optimized based on the ratio of peak height over baseline noise (P/N ratio). The GC/PDD system was compared with a traditional radioactive electron-capture detector (ECD). In the lab, the method detection limit (MDL) of the new GC/PDD method (9 pptv) was lower than the radioactive GC/ECD method (15 pptv), demonstrating its excellent potential. The MDL of GC/PDD in the field campaign at the Mt. Bachelor Observatory (MBO) was 23 pptv, higher than in the lab. This was caused in part by the decreased slope of the calibration curve resulting from the low air pressure level at MBO. However, the MDL level of GC/PDD at MBO is still low enough for accurate PAN measurements, although special attention should be paid to its application at high-elevation sites. Observations of PAN were conducted at MBO in the summer of 2016 with the GC/PDD system, and provided more evidence of the performance of the system. PAN was found to be highly correlated with CO. The promising performance of GC/PDD which does not require a radioactive source makes it a useful approach for accurate PAN measurements in the field.

  2. Cannabinoid findings in children hair - what do they really tell us? An assessment in the light of three different analytical methods with focus on interpretation of Δ9-tetrahydrocannabinolic acid A concentrations.

    PubMed

    Moosmann, Bjoern; Roth, Nadine; Hastedt, Martin; Jacobsen-Bauer, Andrea; Pragst, Fritz; Auwärter, Volker

    2015-05-01

    Hair analysis for drugs and drugs of abuse is increasingly applied in child protection cases. To determine the potential risk to a child living in a household where drugs are consumed, not only can the hair of the parents be analyzed but also the hair of the child. In the case of hair analysis for cannabinoids, the differentiation between external contamination and systemic uptake is particularly difficult, since the drug is quite often handled extensively prior to consumption (e.g. when preparing a joint) and smoke causes a further risk for an external contamination. Δ9-tetrahydrocannabinolic acid A (THCA-A), the non-psychoactive biogenetic precursor of Δ9-tetrahydrocannabinol (THC), is a suitable marker for external contamination since it is not incorporated into the hair matrix through the bloodstream in relevant amounts. In the presented study, hair samples from 41 children, 4 teenagers, and 34 drug-consuming parents were analyzed for THCA-A, THC and cannabinol (CBN) applying methanolic extraction and a fully validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method (Method 1). For comparison, a part of the samples was also analyzed applying alkaline hydrolysis followed by liquid/liquid extraction and gas chromatography-mass spectrometry (GC-M)S (Method 2), or by headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) (Method 3). Furthermore, 458 seized marihuana samples and 180 seized hashish samples were analyzed for the same cannabinoids by gas-chromatography-flame ionization detector (GC-FID). In all but one of the hair samples, the concentration of THCA-A was higher than the concentration of THC and in 14 cases no THC could be detected despite the presence of THCA-A, suggesting that in almost all cases a significant external contamination had occurred. Within-family comparison showed a higher THCA-A/THC ratio in hair of children than of their consuming caregivers. Mean and median of this ratio of all hair samples (6.7 and 4.2) were between those of marihuana (11.0 and 8.3) and hashish (2.8 and 2.1) with a large variation in all samples. Comparison of the Methods 1 to 3 showed clearly that the choice of the analytical procedure has a strong influence on the quantitative results, mainly because of decarboxylation of THCA-A during hair hydrolysis by NaOH and other analytical steps, which lead to artifactually elevated THC concentrations. In conclusion, these findings suggest that the major part of the cannabinoids detected in the hair samples from children arose from an external contamination through 'passive' transfer by e.g. contaminated hands or surfaces and not from inhalation or deposition of side stream smoke. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Pyrolysis-high resolution gas chromatography and pyrolysis gas chromatography-mass spectrometry of kerogens and kerogen precursors

    NASA Technical Reports Server (NTRS)

    Van De Meent, D.; Brown, S. C.; Philp, R. P.; Simoneit, B. R. T.

    1980-01-01

    A series of kerogens and kerogen precursors isolated from DSDP samples, oil shales and recent algal mats have been examined by Curie point pyrolysis-high resolution gas chromatography and gas chromatography-mass spectrometry. This study has shown that the three main types of kerogens (marine, terrestrial and mixtures of both) can be characterized using these techniques. The marine (algal) kerogens yield principally aliphatic products and the terrestrial kerogens yield more aromatic and phenolic products with some n-alkanes and n-alkenes. The yields of n-alkanes and n-alkenes increase and phenols decrease with increasing geologic age, however, pyrolysis-GC cannot be used to characterize the influence of short term diagenesis on the kerogen structure.

  4. Identification of unknown impurity of azelaic acid in liposomal formulation assessed by HPLC-ELSD, GC-FID, and GC-MS.

    PubMed

    Han, Stanisław; Karłowicz-Bodalska, Katarzyna; Potaczek, Piotr; Wójcik, Adam; Ozimek, Lukasz; Szura, Dorota; Musiał, Witold

    2014-02-01

    The identification of new contaminants is critical in the development of new medicinal products. Many impurities, such as pentanedioic acid, hexanedioic acid, heptanedioic acid, octanedioic acid, decanedioic acid, undecanedioic acid, dodecanedioic acid, tridecanedioic acid, and tetradecanedioic acid, have been identified in samples of azelaic acid. The aim of this study was to identify impurities observed during the stability tests of a new liposomal dosage form of azelaic acid that is composed of phosphatidylcholine and a mixture of ethyl alcohol and water, using high-performance liquid chromatography with evaporative light-scattering detector (HPLC-ELSD), gas chromatography-flame ionisation detection (GC-FID), and gas chromatography-mass spectrometry (GC-MS) methods. During the research and development of a new liposomal formulation of azelaic acid, we developed a method for determining the contamination of azelaic acid using HPLC-ELSD. During our analytical tests, we identified a previously unknown impurity of a liposomal preparation of azelaic acid that appeared in the liposomal formulation of azelaic acid during preliminary stability studies. The procedure led to the conclusion that the impurity was caused by the reaction of azelaic acid with one of the excipients that was applied in the product. The impurity was finally identified as an ethyl monoester of azelaic acid. The identification procedure of this compound was carried out in a series of experiments comparing the chromatograms that were obtained via the following chromatographic methods: HPLC-ELSD, GC-FID, and GC-MS. The final identification of the compound was carried out by GC with MS.

  5. Fatty acid amides from freshwater green alga Rhizoclonium hieroglyphicum.

    PubMed

    Dembitsky, V M; Shkrob, I; Rozentsvet, O A

    2000-08-01

    Freshwater green algae Rhizoclonium hieroglyphicum growing in the Ural Mountains were examined for their fatty acid amides using capillary gas chromatography-mass spectrometry (GC-MS). Eight fatty acid amides were identified by GC-MS. (Z)-9-octadecenamide was found to be the major component (2.26%).

  6. Determination of residual acetone and acetone related impurities in drug product intermediates prepared as Spray Dried Dispersions (SDD) using gas chromatography with headspace autosampling (GCHS).

    PubMed

    Quirk, Emma; Doggett, Adrian; Bretnall, Alison

    2014-08-05

    Spray Dried Dispersions (SDD) are uniform mixtures of a specific ratio of amorphous active pharmaceutical ingredient (API) and polymer prepared via a spray drying process. Volatile solvents are employed during spray drying to facilitate the formation of the SDD material. Following manufacture, analytical methodology is required to determine residual levels of the spray drying solvent and its associated impurities. Due to the high level of polymer in the SDD samples, direct liquid injection with Gas Chromatography (GC) is not a viable option for analysis. This work describes the development and validation of an analytical approach to determine residual levels of acetone and acetone related impurities, mesityl oxide (MO) and diacetone alcohol (DAA), in drug product intermediates prepared as SDDs using GC with headspace (HS) autosampling. The method development for these analytes presented a number of analytical challenges which had to be overcome before the levels of the volatiles of interest could be accurately quantified. GCHS could be used after two critical factors were implemented; (1) calculation and application of conversion factors to 'correct' for the reactions occurring between acetone, MO and DAA during generation of the headspace volume for analysis, and the addition of an equivalent amount of polymer into all reference solutions used for quantitation to ensure comparability between the headspace volumes generated for both samples and external standards. This work describes the method development and optimisation of the standard preparation, the headspace autosampler operating parameters and the chromatographic conditions, together with a summary of the validation of the methodology. The approach has been demonstrated to be robust and suitable to accurately determine levels of acetone, MO and DAA in SDD materials over the linear concentration range 0.008-0.4μL/mL, with minimum quantitation limits of 20ppm for acetone and MO, and 80ppm for DAA. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Simultaneous determination of zearalenone and its derivatives in edible vegetable oil by gel permeation chromatography and gas chromatography-triple quadrupole mass spectrometry.

    PubMed

    Qian, Mingrong; Zhang, Hu; Wu, Liqin; Jin, Nuo; Wang, Jianmei; Jiang, Kezhi

    2015-01-01

    A sensitive gas chromatographic-triple quadrupole mass spectrometric (GC-QqQ MS) analytical method, for the determination of zearalenone and its five derivatives in edible vegetable oil, was developed. After the vegetable oil samples were prepared using gel permeation chromatography, the eluent was collected, evaporated and dried with nitrogen gas. The residue was silylated with N,O-bis-trimethylsilyltrifluoroacetamide, containing 1% trimethylchlorosilane. GC-QqQ MS was performed in the reaction-monitoring mode to confirm and quantify mycotoxins in vegetable oil. The limits of quantitation were 0.03-0.2 μg kg(-1) for the six mycotoxins. The average recoveries, measured at 2, 20 and 200 μg kg(-1), were in the range 80.3-96.5%. Zearalenone was detected in the range 5.2-184.6 μg kg(-1) in nine maize oils and at 40.7 μg kg(-1) in a rapeseed oil from the local market. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. An Advanced Analytical Chemistry Experiment Using Gas Chromatography-Mass Spectrometry, MATLAB, and Chemometrics to Predict Biodiesel Blend Percent Composition

    ERIC Educational Resources Information Center

    Pierce, Karisa M.; Schale, Stephen P.; Le, Trang M.; Larson, Joel C.

    2011-01-01

    We present a laboratory experiment for an advanced analytical chemistry course where we first focus on the chemometric technique partial least-squares (PLS) analysis applied to one-dimensional (1D) total-ion-current gas chromatography-mass spectrometry (GC-TIC) separations of biodiesel blends. Then, we focus on n-way PLS (n-PLS) applied to…

  9. Factors That Contribute to Assay Variation in Quantitative Analysis of Sex Steroid Hormones Using Liquid and Gas Chromatography-Mass Spectrometry

    ERIC Educational Resources Information Center

    Xu, Xia; Veenstra, Timothy D.

    2012-01-01

    The list of physiological events in which sex steroids play a role continues to increase. To decipher the roles that sex steroids play in any condition requires high quality cohorts of samples and assays that provide highly accurate quantitative measures. Liquid and gas chromatography coupled with mass spectrometry (LC-MS and GC-MS) have…

  10. A four dimensional separation method based on continuous heart-cutting gas chromatography with ion mobility and high resolution mass spectrometry.

    PubMed

    Lipok, Christian; Hippler, Jörg; Schmitz, Oliver J

    2018-02-09

    A two-dimensional GC (2D-GC) method was developed and coupled to an ion mobility-high resolution mass spectrometer, which enables the separation of complex samples in four dimensions (2D-GC, ion mobilility spectrometry and mass spectrometry). This approach works as a continuous multiheart-cutting GC-system (GC+GC), using a long modulation time of 20s, which allows the complete transfer of most of the first dimension peaks to the second dimension column without fractionation, in comparison to comprehensive two-dimensional gas chromatography (GCxGC). Hence, each compound delivers only one peak in the second dimension, which simplifies the data handling even when ion mobility spectrometry as a third and mass spectrometry as a fourth dimension are introduced. The analysis of a plant extract from Calendula officinales shows the separation power of this four dimensional separation method. The introduction of ion mobility spectrometry provides an additional separation dimension and allows to determine collision cross sections (CCS) of the analytes as a further physicochemical constant supporting the identification. A CCS database with more than 800 standard substances including drug-like compounds and pesticides was used for CCS data base search in this work. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Study on essential oils from the leaves of two Vietnamese plants: Jasminum subtriplinerve C.L. Blume and Vitex quinata (Lour) F.N. Williams.

    PubMed

    Dai, Do N; Thang, Tran D; Ogunwande, Isiaka A; Lawal, Oladipupo A

    2016-01-01

    The essential oil constituents of the leaves of Jasminum subtriplinerve (Oleaceae) and Vitex quinata (Verbanaceae) cultivated in Vietnam were analysed by gas chromatography--flame ionisation detector (GC-FID) and gas chromatography--mass spectrometry (GC-MS) techniques. The main constituents identified in J. subtriplinerve were mainly oxygenated monoterpenes represented by linalool (44.2%), α-terpineol (15.5%), geraniol (19.4%) and cis-linalool oxide (8.8%). The quantitative significant components of V. quinata were terpene hydrocarbons comprising of β-pinene (30.1%), β-caryophyllene (26.9%) and β-elemene (7.4%). The chemical compositions of the essential oils are being reported for the first time.

  12. A quantitative headspace-solid-phase microextraction-gas chromatography-flame ionization detector method to analyze short chain free fatty acids in rat feces.

    PubMed

    Fiorini, Dennis; Boarelli, Maria Chiara; Gabbianelli, Rosita; Ballini, Roberto; Pacetti, Deborah

    2016-09-01

    This study sought to develop and validate a quantitative method to analyze short chain free fatty acids (SCFAs) in rat feces by solid-phase microextraction and gas chromatography (SPME-GC) using the salt mixture ammonium sulfate and sodium dihydrogen phosphate as salting out agent. Conditioning and extraction time, linearity, limits of detection and quantification, repeatability, and recovery were evaluated. The proposed method allows quantification with improved sensitivity as compared with other methods exploiting SPME-GC. The method has been applied to analyze rat fecal samples, quantifying acetic, propionic, isobutyric, butyric, isopentanoic, pentanoic, and hexanoic acids. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Fourier transform infrared spectroscopy techniques for the analysis of drugs of abuse

    NASA Astrophysics Data System (ADS)

    Kalasinsky, Kathryn S.; Levine, Barry K.; Smith, Michael L.; Magluilo, Joseph J.; Schaefer, Teresa

    1994-01-01

    Cryogenic deposition techniques for Gas Chromatography/Fourier Transform Infrared (GC/FT-IR) can be successfully employed in urinalysis for drugs of abuse with detection limits comparable to those of the established Gas Chromatography/Mass Spectrometry (GC/MS) technique. The additional confidence of the data that infrared analysis can offer has been helpful in identifying ambiguous results, particularly, in the case of amphetamines where drugs of abuse can be confused with over-the-counter medications or naturally occurring amines. Hair analysis has been important in drug testing when adulteration of urine samples has been a question. Functional group mapping can further assist the analysis and track drug use versus time.

  14. Online Simultaneous Hydrogen/Deuterium Exchange of Multitarget Gas-Phase Molecules by Electrospray Ionization Mass Spectrometry Coupled with Gas Chromatography.

    PubMed

    Jeong, Eun Sook; Cha, Eunju; Cha, Sangwon; Kim, Sunghwan; Oh, Han Bin; Kwon, Oh-Seung; Lee, Jaeick

    2017-11-21

    In this study, a hydrogen/deuterium (H/D) exchange method using gas chromatography-electrospray ionization/mass spectrometry (GC-ESI/MS) was first investigated as a novel tool for online H/D exchange of multitarget analytes. The GC and ESI source were combined with a homemade heated column transfer line. GC-ESI/MS-based H/D exchange occurs in an atmospheric pressure ion source as a result of reacting the gas-phase analyte eluted from GC with charged droplets of deuterium oxide infused as the ESI spray solvent. The consumption of the deuterated solvent at a flow rate of 2 μL min -1 was more economical than that in online H/D exchange methods reported to date. In-ESI-source H/D exchange by GC-ESI/MS was applied to 11 stimulants with secondary amino or hydroxyl groups. After H/D exchange, the spectra of the stimulants showed unexchanged, partially exchanged, and fully exchanged ions showing various degrees of exchange. The relative abundances corrected for naturally occurring isotopes of the fully exchanged ions of stimulants, except for etamivan, were in the range 24.3-85.5%. Methylephedrine and cyclazodone showed low H/D exchange efficiency under acidic, neutral, and basic spray solvent conditions and nonexchange for etamivan with an acidic phenolic OH group. The in-ESI-source H/D exchange efficiency by GC-ESI/MS was sufficient to determine the number of hydrogen by elucidation of fragmentation from the spectrum. Therefore, this online H/D exchange technique using GC-ESI/MS has potential as an alternative method for simultaneous H/D exchange of multitarget analytes.

  15. Congener-specific determination of ultratrace levels of chlorinated and brominated polycyclic aromatic hydrocarbons in atmosphere and industrial stack gas by isotopic dilution gas chromatography/high resolution mass spectrometry method.

    PubMed

    Jin, Rong; Liu, Guorui; Zheng, Minghui; Fiedler, Heidelore; Jiang, Xiaoxu; Yang, Lili; Wu, Xiaolin; Xu, Yang

    2017-08-04

    Isotopic dilution gas chromatography combined with high resolution mass spectrometry (GC/HRMS) has overwhelming advantages with respect to the accuracy of congener-specific ultratrace analysis of complex persistent organic pollutants (POPs) in environmental matrices. However, an isotopic dilution GC/HRMS method for analysis of chlorinated and brominated polycyclic aromatic hydrocarbons (Cl-PAHs and Br-PAHs) using 13 C-labelled congeners as internal standards has not been established. In this study, a method for identification and quantification of 38 congeners of Cl-PAHs and Br-PAHs in atmosphere and stack gas samples from waste incinerators was developed using the isotopic dilution GC/HRMS technique. The instrumental detection limits of the GC/HRMS method ranged from 0.2pg to 1.8pg for Cl-PAH congeners, and 0.7pg to 2.7pg for Br-PAH congeners, which were about three orders of magnitude lower than those of the GC/quadrupole MS method. This new method developed was also the first to enable determination of Cl-PAH and Br-PAH homologs comprising congeners with the same molecular skeleton and chlorine or bromine substitution numbers. Among the detected congeners, seven Cl-PAH congeners and thirteen Br-PAH congeners that were abundant in the atmosphere and stack gases released from waste incinerators were firstly detected in real samples and reported using the established isotopic dilution GC/HRMS method. The developed isotopic dilution GC/HRMS is significant and needed for better studying the environmental behavior and health risk of Cl-PAHs and Br-PAHs. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Analysis of volatile human urinary metabolome by solid-phase microextraction in combination with gas chromatography-mass spectrometry for biomarker discovery: application in a pilot study to discriminate patients with renal cell carcinoma.

    PubMed

    Monteiro, Márcia; Carvalho, Márcia; Henrique, Rui; Jerónimo, Carmen; Moreira, Nathalie; de Lourdes Bastos, Maria; de Pinho, Paula Guedes

    2014-07-01

    A new and simple analytical approach consisting of headspace-solid phase microextraction (HS-SPME) sampling coupled with gas chromatography-ion trap/mass spectrometry (GC-IT/MS) was developed to study the volatile human urinary metabolome. A central composite design (CCD) was used in the optimisation of extraction conditions. Fibre selection and evaluation of pH influence were performed using an univariate mode and the influence of other parameters, such as the time and temperature of extraction, time of incubation and salt addition, that affect the efficiency of the SPME sampling, was carried out using a CCD. With a sample volume of 2 mL, the optimal conditions in terms of total response values and reproducibility were achieved by performing analyses with a divinylbenzene/polydimethylsiloxane (DVB/PDMS) fibre, in an acidic pH (pH 2) with the addition of 0.59 g of NaCl, allowing the sample to equilibrate for 9 min and extracting at 68 °C for 24 min. The applicability of the optimised method was then tested in a pilot non-target analysis of urine samples obtained from patients with renal cell carcinoma (RCC) and healthy individuals. Chemometric unsupervised analyses performed on the volatile pattern acquired for these samples clearly showed the potential of volatile urinary metabolome to discriminate between RCC and control patients. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Characterization of Volatile Sulfur Compounds in Moutai Liquors by Headspace Solid-Phase Microextraction Gas Chromatography-Pulsed Flame Photometric Detection and Odor Activity Value.

    PubMed

    Chen, Shuang; Sha, Sha; Qian, Michael; Xu, Yan

    2017-12-01

    This study investigated the aroma contribution of volatile sulfur compounds (VSCs) in Moutai liquors. The VSCs were analyzed using headspace solid-phase microextraction-gas chromatography-pulsed flame photometric detection (HS-SPME-GC-PFPD). The influences of SPME fibers, ethanol content in the sample, pre-incubation time, and extraction temperature and time on the extraction of VSCs were optimized. The VSCs were optimally extracted using a divinylbenzene/carboxen/polydimethylsiloxane fiber, by incubating 10 mL diluted Chinese liquor (5% vol.) with 3 g NaCl at 30 °C for 15 min, followed by a subsequent extraction for 40 min at 30 °C. The optimized method was further validated. A total of 13 VSCs were identified and quantified in Moutai liquors. The aroma contribution of these VSCs were evaluated by their odor activity values (OAVs), with the result that 7 of 13 VSCs had OAVs > 1. In particular, 2-furfurylthiol, methanethiol, dimethyl trisulfide, ethanethiol, and methional had relatively high OAVs and could be the key aroma contributors to Moutai liquors. In this study, a method for analyzing volatile sulfur compounds in Chinese liquors has been developed. This method will allow an in-depth study the aroma contribution of volatile sulfur compounds in Chinese liquors. Seven volatile sulfur compounds were identified as potential key aroma contributors for Moutai liquors, which can help to the quality control of Moutai liquors. © 2017 Institute of Food Technologists®.

  18. Analytical tools for identification of non-intentionally added substances (NIAS) coming from polyurethane adhesives in multilayer packaging materials and their migration into food simulants.

    PubMed

    Félix, Juliana S; Isella, Francesca; Bosetti, Osvaldo; Nerín, Cristina

    2012-07-01

    Adhesives used in food packaging to glue different materials can provide several substances as potential migrants, and the identification of potential migrants and migration tests are required to assess safety in the use of adhesives. Solid-phase microextraction in headspace mode and gas chromatography coupled to mass spectrometry (HS-SPME-GC-MS) and ChemSpider and SciFinder databases were used as powerful tools to identify the potential migrants in the polyurethane (PU) adhesives and also in the individual plastic films (polyethylene terephthalate, polyamide, polypropylene, polyethylene, and polyethylene/ethyl vinyl alcohol). Migration tests were carried out by using Tenax(®) and isooctane as food simulants, and the migrants were analyzed by gas chromatography coupled to mass spectrometry. More than 63 volatile and semivolatile compounds considered as potential migrants were detected either in the adhesives or in the films. Migration tests showed two non-intentionally added substances (NIAS) coming from PU adhesives that migrated through the laminates into Tenax(®) and into isooctane. Identification of these NIAS was achieved through their mass spectra, and 1,6-dioxacyclododecane-7,12-dione and 1,4,7-trioxacyclotridecane-8,13-dione were confirmed. Caprolactam migrated into isooctane, and its origin was the external plastic film in the multilayer, demonstrating real diffusion through the multilayer structure. Comparison of the migration values between the simulants and conditions will be shown and discussed.

  19. Web Server for Peak Detection, Baseline Correction, and Alignment in Two-Dimensional Gas Chromatography Mass Spectrometry-Based Metabolomics Data.

    PubMed

    Tian, Tze-Feng; Wang, San-Yuan; Kuo, Tien-Chueh; Tan, Cheng-En; Chen, Guan-Yuan; Kuo, Ching-Hua; Chen, Chi-Hsin Sally; Chan, Chang-Chuan; Lin, Olivia A; Tseng, Y Jane

    2016-11-01

    Two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC/TOF-MS) is superior for chromatographic separation and provides great sensitivity for complex biological fluid analysis in metabolomics. However, GC×GC/TOF-MS data processing is currently limited to vendor software and typically requires several preprocessing steps. In this work, we implement a web-based platform, which we call GC 2 MS, to facilitate the application of recent advances in GC×GC/TOF-MS, especially for metabolomics studies. The core processing workflow of GC 2 MS consists of blob/peak detection, baseline correction, and blob alignment. GC 2 MS treats GC×GC/TOF-MS data as pictures and clusters the pixels as blobs according to the brightness of each pixel to generate a blob table. GC 2 MS then aligns the blobs of two GC×GC/TOF-MS data sets according to their distance and similarity. The blob distance and similarity are the Euclidean distance of the first and second retention times of two blobs and the Pearson's correlation coefficient of the two mass spectra, respectively. GC 2 MS also directly corrects the raw data baseline. The analytical performance of GC 2 MS was evaluated using GC×GC/TOF-MS data sets of Angelica sinensis compounds acquired under different experimental conditions and of human plasma samples. The results show that GC 2 MS is an easy-to-use tool for detecting peaks and correcting baselines, and GC 2 MS is able to align GC×GC/TOF-MS data sets acquired under different experimental conditions. GC 2 MS is freely accessible at http://gc2ms.web.cmdm.tw .

  20. In situ analysis of martian regolith with the SAM experiment during the first mars year of the MSL mission: Identification of organic molecules by gas chromatography from laboratory measurements

    NASA Astrophysics Data System (ADS)

    Millan, M.; Szopa, C.; Buch, A.; Coll, P.; Glavin, D. P.; Freissinet, C.; Navarro-Gonzalez, R.; François, P.; Coscia, D.; Bonnet, J. Y.; Teinturier, S.; Cabane, M.; Mahaffy, P. R.

    2016-09-01

    The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover, is specifically designed for in situ molecular and isotopic analyses of martian surface materials and atmosphere. It contributes to the Mars Science Laboratory (MSL) missions primary scientific goal to characterize the potential past, present or future habitability of Mars. In all of the analyses of solid samples delivered to SAM so far, chlorinated organic compounds have been detected above instrument background levels and identified by gas chromatography coupled to mass spectrometry (GC-MS) (Freissinet et al., 2015; Glavin et al., 2013). While some of these may originate from reactions between oxychlorines and terrestrial organic carbon present in the instrument background (Glavin et al., 2013), others have been demonstrated to originate from indigenous organic carbon present in samples (Freissinet et al., 2015). We present here laboratory calibrations that focused on the analyses performed with the MXT-CLP GC column (SAM GC-5 channel) used for nearly all of the GC-MS analyses of the martian soil samples carried out with SAM to date. Complementary to the mass spectrometric data, gas chromatography allows us to separate and identify the species analyzable in a nominal SAM-GC run time of about 21 min. To characterize the analytical capabilities of this channel within the SAM Flight Model (FM) operating conditions on Mars, and their implications on the detection of organic matter, it is required to perform laboratory experimental tests and calibrations on spare model components. This work assesses the SAM flight GC-5 column efficiency, confirms the identification of the molecules based on their retention time, and enables a better understanding of the behavior of the SAM injection trap (IT) and its release of organic molecules. This work will enable further optimization of the SAM-GC runs for additional samples to be analyzed during the MSL mission.

  1. In Situ Analysis of Martian Regolith with the SAM Experiment During the First Mars Year of the MSL Mission: Identification of Organic Molecules by Gas Chromatography from Laboratory Measurements

    NASA Technical Reports Server (NTRS)

    Millan, M.; Szopa, C.; Buch, A.; Coll, P.; Glavin, D. P.; Freissinet, C.; Navarro-Gonzalez, R.; Francois, P.; Coscia, D.; Bonnet, J. Y.; hide

    2016-01-01

    The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover, is specifically designed for in situ molecular and isotopic analyses of martian surface materials and atmosphere. It contributes to the Mars Science Laboratory (MSL) missions primary scientific goal to characterize the potential past, present or future habitability of Mars. In all of the analyses of solid samples delivered to SAM so far, chlorinated organic compounds have been detected above instrument background levels and identified by gas chromatography coupled to mass spectrometry (GC-MS) (Freissinet et al., 2015; Glavin et al., 2013). While some of these may originate from reactions between oxychlorines and terrestrial organic carbon present in the instrument background (Glavin et al., 2013), others have been demonstrated to originate from indigenous organic carbon present in samples (Freissinet et al., 2015). We present here laboratory calibrations that focused on the analyses performed with the MXT-CLP GC column (SAM GC-5 channel) used for nearly all of the GC-MS analyses of the martian soil samples carried out with SAM to date. Complementary to the mass spectrometric data, gas chromatography allows us to separate and identify the species analyzable in a nominal SAM-GC run time of about 21 min. To characterize the analytical capabilities of this channel within the SAM Flight Model (FM) operating conditions on Mars, and their implications on the detection of organic matter, it is required to perform laboratory experimental tests and calibrations on spare model components. This work assesses the SAM flight GC-5 column efficiency, confirms the identification of the molecules based on their retention time, and enables a better understanding of the behavior of the SAM injection trap (IT) and its release of organic molecules. This work will enable further optimization of the SAM-GC runs for additional samples to be analyzed during the MSL mission.

  2. Determination of nandrolone and metabolites in urine samples from sedentary persons and sportsmen.

    PubMed

    Galán Martín, A M; Mariño, J I; García de Tiedra, M P; Marabé, J J; Caballero Loscos, M J; Mariño, M M

    2001-09-25

    Metabolites of nandrolone were determined in the urine of several sportsmen, sedentary and post-menopausal women by capillary gas chromatography-mass spectrometry quadrupole (GC-MS) and capillary gas chromatography mass-mass spectrometry ion trap (GC-MS-MS) methods. The method employed was GC-EI-MS with 17alpha-methyltestosterone as internal standard with ethyl ether extraction prior to selected ion monitoring of the bis(trimethylsilyl) ethers at ion masses m/z 405 and 420 for the nandrolone metabolites, and 418 and 403 for nandrolone derivative. Recovery for nandrolone, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) was 97.20, 94.17 and 95.54%, respectively. Detection limits for nandrolone, 19-NA and 19-NE were 0.03, 0.01 and 0.06 ng/ml. Metabolites of nandrolone (19-NA and 19-NE) were found in 12.5% (n = 40) of sportsmen and 40% (n = 10) of post-menopausal women.

  3. THE ROLE OF GC/MS AND LC/MS IN THE DISCOVERY OF DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Gas chromatography/mass spectrometry (GC/MS) has played a pivotal role in the discovery of disinfection by-products (DBPs) in drinking water. DBPs are formed when disinfectants, such as chlorine, ozone, chlorine dioxide, or chloramine, react with natural organic matter in the ...

  4. GC-O, volatile and qualitative differences in locally grown rabbiteye and southern highbush blueberries, and juices

    USDA-ARS?s Scientific Manuscript database

    Southern and southeastern US production of blueberries has increased markedly in recent years. Gas chromatography-olfactometry (GC-O) and volatile and semi-volatile compounds are seldom reported in rabbiteye blueberry (RAB). Few comparisons have been made between the organoleptic differences betwe...

  5. Bromination of Aromatic Compounds by Residual Bromide in Sodium Chloride Matrix Modifier Salt During Heated Headspace GC/MS Analysis

    EPA Science Inventory

    Analytical artifacts attributed to the bromination of toluene, xylenes, and trimethylbenzenes were found during the heated headspace gas chromatography/mass spectrometry (GC/MS) analysis of aqueous samples. The aqueous samples were produced from Fenton-like chemical oxidation rea...

  6. Ultratrace detector for hand-held gas chromatography

    DOEpatents

    Andresen, Brian D.; Miller, Fred S.

    1999-01-01

    An ultratrace detector system for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and C0.sub.2. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica--or other metal--aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.

  7. Chemotaxonomic differentiation of legionellae by detection and characterization of aminodideoxyhexoses and other unique sugars using gas chromatography-mass spectrometry.

    PubMed Central

    Fox, A; Rogers, J C; Fox, K F; Schnitzer, G; Morgan, S L; Brown, A; Aono, R

    1990-01-01

    Legionellae have been differentiated previously by analyzing their carbohydrate contents by gas chromatography with flame ionization detection. In the present study, total ion mode gas chromatography-mass spectrometry (GC-MS) was used to detect a number of unusual sugars, including one that is structurally related to O-methyldideoxyheptoses. Increased sensitivity and selectivity for carbohydrate detection was achieved by selected ion-monitoring GC-MS. Two of the uncommon sugars previously discovered in the legionellae (X1 and X2) were identified as quinovosamine and fucosamine, respectively. Legionella pneumophila contained rhamnose and quinovosamine but not the quinovosamine isomer fucosamine. Tatlockia micdadei and Legionella maceachernii contained large amounts of rhamnose, fucose, and fucosamine but not quinovosamine. These two species were the only legionellae studied that contained another unusual sugar that is referred to as X3, pending determination of its structure. Fluoribacter dumoffi, Fluoribacter bozemanae, and Legionella anisa were varied in their carbohydrate contents, both within and between species, but could be distinguished from L. pneumophila and the T. micdadei and L. maceachernii group. Fluoribacter gormanii was unique among the legionellae in that it lacked both quinovosamine and fucosamine. Legionella jordanis contained other unusual carbohydrates in addition to quinovosamine. GC-MS may have wide application in the differentiation of bacterial species. PMID:2324276

  8. Qualitative and Quantitative Analysis of Volatile Components of Zhengtian Pills Using Gas Chromatography Mass Spectrometry and Ultra-High Performance Liquid Chromatography.

    PubMed

    Liu, Cui-Ting; Zhang, Min; Yan, Ping; Liu, Hai-Chan; Liu, Xing-Yun; Zhan, Ruo-Ting

    2016-01-01

    Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R (2) ≥ 0.9992), precision (RSD < 3%), accuracy (100.68-102.69%), and robustness. The UHPLC-DAD/GC-MS method was successfully utilized to analyze volatile components, protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs.

  9. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.

    1989-01-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan-Cassini entry probe, which is being jointly planned by NASA and the European Space Agency (ESA), might be launched as early as 1994. As in the Pioneer mission, limited time--perhaps only 3-4 h--will be available for the completion of all analyses while the probe descends through the atmosphere. A conventional GC or GC-MS system would be able to analyze no more than two aerosol and two gas samples during the probe's descent. Conventional GC also is limited by the sensitivity of the detector and by the sample volume. For the Titan mission, the sensitivity problems will be worse because the atmospheric pressure at the time of instrument deployment is expected to be < 3 torr. Consequently, the sample volume might not be large enough to satisfy the detector sensitivity requirements. Because of such limitations, alternative GC analysis techniques have been investigated for future NASA missions. Multiplex gas chromatography has been investigated as a possible candidate for chemical analysis within a spacecraft or other restricted environment, and chemical modulators have been developed and used when needed with this technique to reduce the size and weight of the instrumentation. Also, several new multiplex techniques have been developed for use in specific applications.

  10. Concurrent Lactic and Volatile Fatty Acid Analysis of Microbial Fermentation Samples by Gas Chromatography with Heat Pre-treatment.

    PubMed

    Darwin; WipaCharles; Cord-Ruwisch, Ralf

    2018-01-01

    Organic acid analysis of fermentation samples can be readily achieved by gas chromatography (GC), which detects volatile organic acids. However, lactic acid, a key fermentation acid is non-volatile and can hence not be quantified by regular GC analysis. However the addition of periodic acid to organic acid samples has been shown to enable lactic acid analysis by GC, as periodic acid oxidizes lactic acid to the volatile acetaldehyde. Direct GC injection of lactic acid standards and periodic acid generated inconsistent and irreproducible peaks, possibly due to incomplete lactic acid oxidation to acetaldehyde. The described method is developed to improve lactic acid analysis by GC by using a heat treated derivatization pre-treatment, such that it becomes independent of the retention time and temperature selection of the GC injector. Samples containing lactic acid were amended by periodic acid and heated in a sealed test tube at 100°C for at least 45 min before injecting it to the GC. Reproducible and consistent peaks of acetaldehyde were obtained. Simultaneous determination of lactic acid, acetone, ethanol, butanol, volatile fatty acids could also be accomplished by applying this GC method, enabling precise and convenient organic acid analysis of biological samples such as anaerobic digestion and fermentation processes. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. State-of-the art of selective detection and identification of I-, Br-, Cl-, and F-containing compounds in gas chromatography and liquid chromatography.

    PubMed

    Brede, Cato; Pedersen-Bjergaard, Stig

    2004-09-24

    This review article presents an overview of halogen-specific detection in gas chromatography (GC) and liquid chromatography (LC). Attention is primarily focused on the use of plasma emission spectroscopy and plasma mass spectrometry as detectors, but other halogen-selective detection principles are also mentioned. Different instrumental configurations are discussed both with respect to technical set-up and performance, the principal reasons for halogen-selective detection are highlighted, and recent applications are reviewed from areas such as environmental chemistry, petroleum characterization, and drug analysis.

  12. FIELD TRAPPING OF SUBSURFACE VAPOR PHASE PETROLEUM HYDROCARBONS

    EPA Science Inventory

    Soil gas samples from intact soil cores were collected on adsorbents at a field site, then thermally desorbed and analyzed by laboratory gas chromatography (GC). ertical concentration profiles of predominant vapor phase petroleum hydrocarbons under ambient conditions were obtaine...

  13. Development of a HS-SPME-GC/MS protocol assisted by chemometric tools to study herbivore-induced volatiles in Myrcia splendens.

    PubMed

    Souza Silva, Érica A; Saboia, Giovanni; Jorge, Nina C; Hoffmann, Camila; Dos Santos Isaias, Rosy Mary; Soares, Geraldo L G; Zini, Claudia A

    2017-12-01

    A headspace solid phase microextraction (HS-SPME) method combined with gas chromatography-mass spectrometry (GC/MS) was developed and optimized for extraction and analysis of volatile organic compounds (VOC) of leaves and galls of Myrcia splendens. Through a process of optimization of main factors affecting HS-SPME efficiency, the coating divivnilbenzene-carboxen-polydimethylsiloxane (DVB/Car/PDMS) was chosen as the optimum extraction phase, not only in terms of extraction efficiency, but also for its broader analyte coverage. Optimum extraction temperature was 30°C, while an extraction time of 15min provided the best compromise between extraction efficiencies of lower and higher molecular weight compounds. The optimized protocol was demonstrated to be capable of sampling plant material with high reproducibility, considering that most classes of analytes met the 20% RSD FDA criterion. The optimized method was employed for the analysis of three classes of M. splendens samples, generating a final list of 65 tentatively identified VOC, including alcohols, aldehydes, esters, ketones, phenol derivatives, as well as mono and sesquiterpenes. Significant differences were evident amongst the volatile profiles obtained from non-galled leaves (NGL) and leaf-folding galls (LFG) of M. splendens. Several differences pertaining to amounts of alcohols and aldehydes were detected between samples, particularly regarding quantities of green leaf volatiles (GLV). Alcohols represented about 14% of compounds detected in gall samples, whereas in non-galled samples, alcohol content was below 5%. Phenolic derived compounds were virtually absent in reference samples, while in non-galled leaves and galls their content ranged around 0.2% and 0.4%, respectively. Likewise, methyl salicylate, a well-known signal of plant distress, amounted for 1.2% of the sample content of galls, whereas it was only present in trace levels in reference samples. Chemometric analysis based on Heatmap associated with Hierarchical Cluster Analysis (HCA) and Principal Component Analysis (PCA) provided a suitable tool to differentiate VOC profiles in vegetal material, and could open new perspectives and opportunities in agricultural and ecological studies for the detection and identification of herbivore-induced plant VOC emissions. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Identification of Bound Nitro Musk-Protein Adduct in Fish Liver By Gas Chromatography-Mass Sectrometry: Biotransformation, Dose-Response and Toxicokinetics of Nitro Musk Metabolites Protein Adducts in Trout Liver as Biomarker of Exposure

    EPA Science Inventory

    Ubiquitous occurrences of synthetic nitro musks are evident in the literature. The In vivo analysis of musk xylene (MX) and musk ketone (MK) - protein adducts in trout liver have been performed by gas chromatography-mass spectrometry using selected ion monitoring (GC-SIM-MS). Bio...

  15. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors derived from the sample preparation step.

  16. Optimisation of a simple and reliable method based on headspace solid-phase microextraction for the determination of volatile phenols in beer.

    PubMed

    Pizarro, C; Pérez-del-Notario, N; González-Sáiz, J M

    2010-09-24

    A simple, accurate and sensitive method based on headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed for the analysis of 4-ethylguaiacol, 4-ethylphenol, 4-vinylguaiacol and 4-vinylphenol in beer. The effect of the presence of CO2 in the sample on the extraction of analytes was examined. The influence on extraction efficiency of different fibre coatings, of salt addition and stirring was also evaluated. Divinylbenzene/carboxen/polydimethylsiloxane was selected as extraction fibre and was used to evaluate the influence of exposure time, extraction temperature and sample volume/total volume ratio (Vs/Vt) by means of a central composite design (CCD). The optimal conditions identified were 80 degrees C for extraction temperature, 55 min for extraction time and 6 mL of beer (Vs/Vt 0.30). Under optimal conditions, the proposed method showed satisfactory linearity (correlation coefficients between 0.993 and 0.999), precision (between 6.3% and 9.7%) and detection limits (lower than those previously reported for volatile phenols in beers). The method was applied successfully to the analysis of beer samples. To our knowledge, this is the first time that a HS-SPME based method has been developed to determine simultaneously these four volatile phenols in beers. Copyright 2010 Elsevier B.V. All rights reserved.

  17. [Determination of fatty acids in natural cream and artificial cream by comprehensive two-dimensional gas chromatography-mass spectrometry].

    PubMed

    Zhou, Ruize; Zhou, Ya; Mao, Ting; Jiang, Jie

    2018-01-08

    A method for the determination of 37 fatty acids in natural cream and artificial cream was developed by comprehensive two-dimensional gas chromatography-mass spectrometry (GC×GC-MS). The samples were extracted with toluene and acetyl chloride-methanol (1:9,v/v) solution was added to the extract for fat esterification. Finally, the fatty acids were analyzed by GC×GC-MS. The GC conditions were as follows:a DB-5 column (30 m×0.25 mm×0.25 μm) was set as the 1st dimensional column and a BPX-50 column (2.5 m×0.1 mm×0.25 μm) was the 2nd dimensional column. The primary oven temperature was programmed from 50℃ (held for 2 min) to 180℃ at a rate of 20℃/min, followed by an increase to 250℃ at 2.5℃/min, then raised up to 300℃ (held for 5 min) at 3℃/min. The ion source temperature was 200℃ with auxiliary temperature of 300℃ in scan mode. All fatty acids were separated effectively and determined accurately while the modulation period was 5s and the scan range of MS was m/z 40-385. This procedure was applied to analyze the fatty acids in commercial natural cream and artificial cream from Chinese markets, among which we found the characteristic components in different kinds of samples. Compared with gas chromatography-flame ionization detector (GC-FID), GC×GC-MS method was more sensitive and more components of fatty acids were detected. Conclusively, this work suggests a new technical approach in analyzing fatty acids in natural cream and artificial cream, which is meaningful to ensure the quality identification and safety of natural cream.

  18. Characterization of the Key Aroma Volatile Compounds in Cranberry (Vaccinium macrocarpon Ait.) Using Gas Chromatography-Olfactometry (GC-O) and Odor Activity Value (OAV).

    PubMed

    Zhu, JianCai; Chen, Feng; Wang, LingYing; Niu, YunWei; Chen, HeXing; Wang, HongLin; Xiao, ZuoBing

    2016-06-22

    The volatile compounds of cranberries obtained from four cultivars (Early Black, Y1; Howes, Y2; Searles, Y3; and McFarlin, Y4) were analyzed by gas chromatography-olfactometry (GC-O), gas chromatography-mass spectrometry (GC-MS), and GC-flame photometric detection (FPD). The result presented that a total of thirty-three, thirty-four, thirty-four, and thirty-six odor-active compounds were identified by GC-O in the Y1, Y2, Y3, and Y4, respectively. In addition, twenty-two, twenty-two, thirty, and twenty-seven quantified compounds were demonstrated as important odorants according to odor activity values (OAVs > 1). Among these compounds, hexanal (OAV: 27-60), pentanal (OAV: 31-51), (E)-2-heptenal (OAV: 17-66), (E)-2-hexenal (OAV: 18-63), (E)-2-octenal (OAV: 10-28), (E)-2-nonenal (OAV: 8-77), ethyl 2-methylbutyrate (OAV: 10-33), β-ionone (OAV: 8-73), 2-methylbutyric acid (OAV: 18-37), and octanal (OAV: 4-24) contributed greatly to the aroma of cranberry. Partial least-squares regression (PLSR) was used to process the mean data accumulated from sensory evaluation by the panelists, odor-active aroma compounds (OAVs > 1), and samples. Sample Y3 was highly correlated with the sensory descriptors "floral" and "fruity". Sample Y4 was greatly related to the sensory descriptors "mellow" and "green and grass". Finally, an aroma reconstitution (Model A) was prepared by mixing the odor-active aroma compounds (OAVs > 1) based on their measured concentrations in the Y1 sample, indicating that the aroma profile of the reconstitution was pretty similar to that of the original sample.

  19. Development of new method of δ13C measurement for trace hydrocarbons in natural gas using solid phase micro-extraction coupled to gas chromatography isotope ratio mass spectrometry.

    PubMed

    Li, Zhongping; Wang, Xibin; Li, Liwu; Zhang, Mingjie; Tao, Mingxin; Xing, Lantian; Cao, Chunhui; Xia, Yanqing

    2014-11-01

    Compound specific isotope analysis (CSIA) of normal-level hydrocarbons (C 1 -C 4 ) in natural gas is often successfully used in natural gas origin identification and classification, but little progress so far has been made for trace level hydrocarbons (C 5 -C 14 ) in natural gas. In this study, we developed a method for rapid analysis of carbon isotopic ratios for trace hydrocarbons in natural gas samples. This method can be described as a combined approach characterized by solid phase micro-extraction (SPME) technique coupled to gas chromatography isotope ratio mass spectrometry (GC/IRMS). In this study, the CAR-PDMS fiber was chosen as the SPME adsorptive material after comparative experiments with other four fibers, and the parameters, including equilibration time, extraction temperature and desorption time, for efficient extraction of trace hydrocarbons were systematically optimized. The results showed the carbon isotopic fractionation was not observed as a function of equilibration time and extraction temperature. And the δ 13 C signatures determined by SPME-GC/IRMS were in good agreement with the known δ 13 C values of C 5 -C 14 measured by GC-IRMS, and the accuracy is generally within ±0.5‰. Five natural gas samples were analyzed using this method, and the δ 13 C values for C 5 -C 14 components were obtained with satisfied repeatability. The SPME-GC/IRMS approach fitted with CAR-PDMS fiber is well suited for the preconcentration of trace hydrocarbons and provides so far the most reliable carbon isotopic analysis for trace compounds in natural gas. Published by Elsevier B.V.

  20. Impacts on the metabolome of down-regulating polyphenol oxidase in transgenic potato tubers

    USDA-ARS?s Scientific Manuscript database

    Tubers of potato (Solanum tuberosum L. cv. Estima) genetically modified (GM) to reduce polyphenol oxidase (PPO) activity and enzymatic discolouration were assessed for changes in the metabolome using Liquid Chromatography-Mass Spectrometry (LC-MS) and Gas Chromatography (GC)-MS. Metabolome changes ...

  1. Microwave assisted saponification (MAS) followed by on-line liquid chromatography (LC)-gas chromatography (GC) for high-throughput and high-sensitivity determination of mineral oil in different cereal-based foodstuffs.

    PubMed

    Moret, Sabrina; Scolaro, Marianna; Barp, Laura; Purcaro, Giorgia; Conte, Lanfranco S

    2016-04-01

    A high throughput, high-sensitivity procedure, involving simultaneous microwave-assisted extraction (MAS) and unsaponifiable extraction, followed by on-line liquid chromatography (LC)-gas chromatography (GC), has been optimised for rapid and efficient extraction and analytical determination of mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH) in cereal-based products of different composition. MAS has the advantage of eliminating fat before LC-GC analysis, allowing an increase in the amount of sample extract injected, and hence in sensitivity. The proposed method gave practically quantitative recoveries and good repeatability. Among the different cereal-based products analysed (dry semolina and egg pasta, bread, biscuits, and cakes), egg pasta packed in direct contact with recycled paperboard had on average the highest total MOSH level (15.9 mg kg(-1)), followed by cakes (10.4 mg kg(-1)) and bread (7.5 mg kg(-1)). About 50% of the pasta and bread samples and 20% of the biscuits and cake samples had detectable MOAH amounts. The highest concentrations were found in an egg pasta in direct contact with recycled paperboard (3.6 mg kg(-1)) and in a milk bread (3.6 mg kg(-1)). Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Alkaloids Profiling of Fumaria capreolata by Analytical Platforms Based on the Hyphenation of Gas Chromatography and Liquid Chromatography with Quadrupole-Time-of-Flight Mass Spectrometry.

    PubMed

    Contreras, María Del Mar; Bribi, Noureddine; Gómez-Caravaca, Ana María; Gálvez, Julio; Segura-Carretero, Antonio

    2017-01-01

    Two analytical platforms, gas chromatography (GC) coupled to quadrupole-time-of-flight (QTOF) mass spectrometry (MS) and reversed-phase ultrahigh performance liquid chromatography (UHPLC) coupled to diode array (DAD) and QTOF detection, were applied in order to study the alkaloid profile of Fumaria capreolata . The use of these mass analyzers enabled tentatively identifying the alkaloids by matching their accurate mass signals and suggested molecular formulae with those previously reported in libraries and databases. Moreover, the proposed structures were corroborated by studying their fragmentation pattern obtained by both platforms. In this way, 8 and 26 isoquinoline alkaloids were characterized using GC-QTOF-MS and RP-UHPLC-DAD-QTOF-MS, respectively, and they belonged to the following subclasses: protoberberine, protopine, aporphine, benzophenanthridine, spirobenzylisoquinoline, morphinandienone, and benzylisoquinoline. Moreover, the latter analytical method was selected to determine at 280 nm the concentration of protopine (9.6 ± 0.7 mg/g), a potential active compound of the extract. In conclusion, although GC-MS has been commonly used for the analysis of this type of phytochemicals, RP-UHPLC-DAD-QTOF-MS provided essential complementary information. This analytical method can be applied for the quality control of phytopharmaceuticals containing Fumaria extracts currently found in the market.

  3. Alkaloids Profiling of Fumaria capreolata by Analytical Platforms Based on the Hyphenation of Gas Chromatography and Liquid Chromatography with Quadrupole-Time-of-Flight Mass Spectrometry

    PubMed Central

    Bribi, Noureddine; Gómez-Caravaca, Ana María

    2017-01-01

    Two analytical platforms, gas chromatography (GC) coupled to quadrupole-time-of-flight (QTOF) mass spectrometry (MS) and reversed-phase ultrahigh performance liquid chromatography (UHPLC) coupled to diode array (DAD) and QTOF detection, were applied in order to study the alkaloid profile of Fumaria capreolata. The use of these mass analyzers enabled tentatively identifying the alkaloids by matching their accurate mass signals and suggested molecular formulae with those previously reported in libraries and databases. Moreover, the proposed structures were corroborated by studying their fragmentation pattern obtained by both platforms. In this way, 8 and 26 isoquinoline alkaloids were characterized using GC-QTOF-MS and RP-UHPLC-DAD-QTOF-MS, respectively, and they belonged to the following subclasses: protoberberine, protopine, aporphine, benzophenanthridine, spirobenzylisoquinoline, morphinandienone, and benzylisoquinoline. Moreover, the latter analytical method was selected to determine at 280 nm the concentration of protopine (9.6 ± 0.7 mg/g), a potential active compound of the extract. In conclusion, although GC-MS has been commonly used for the analysis of this type of phytochemicals, RP-UHPLC-DAD-QTOF-MS provided essential complementary information. This analytical method can be applied for the quality control of phytopharmaceuticals containing Fumaria extracts currently found in the market. PMID:29348751

  4. A volatile organic analyzer for Space Station: Description and evaluation of a gas chromatography/ ion mobility

    NASA Technical Reports Server (NTRS)

    Limero, Thomas F.; James, John T.

    1994-01-01

    A Volatile Organic Analyzer (VOA) is being developed as an essential component of the Space Station's Environmental Health System (EHS) air quality monitoring strategy to provide warning to the crew and ground personnel if volatile organic compounds exceed established exposure limits. The short duration of most Shuttle flights and the relative simplicity of the contaminant removal mechanism have lessened the concern about crew exposure to air contaminants on the Shuttle. However, the longer missions associated with the Space Station, the complex air revitalization system and the proposed number of experiments have led to a desire for real-time monitoring of the contaminants in the Space Station atmosphere. Achieving the performance requirements established for the VOA within the Space Station resource (e.g., power, weight) allocations led to a novel approach that joined a gas chromatograph (GC) to an ion mobility spectrometer (IMS). The authors of this paper will discuss the rational for selecting the GC/IMS technology as opposed to the more established gas chromatography/mass spectrometry (GC/MS) for the foundation of the VOA. The data presented from preliminary evaluations will demonstrate the versatile capability of the GC/IMS to analyze the major contaminants expected in the Space Station atmosphere. The favorable GC/IMS characteristics illustrated in this paper included excellent sensitivity, dual-mode operation for selective detection, and mobility drift times to distinguish co-eluting GC peaks. Preliminary studies have shown that the GC/IMS technology can meet surpass the performance requirements of the Space Station VOA.

  5. Enhanced Characterization of the Smell of Death by Comprehensive Two-Dimensional Gas Chromatography-Time-of-Flight Mass Spectrometry (GCxGC-TOFMS)

    PubMed Central

    Dekeirsschieter, Jessica; Stefanuto, Pierre-Hugues; Brasseur, Catherine; Haubruge, Eric; Focant, Jean-François

    2012-01-01

    Soon after death, the decay process of mammalian soft tissues begins and leads to the release of cadaveric volatile compounds in the surrounding environment. The study of postmortem decomposition products is an emerging field of study in forensic science. However, a better knowledge of the smell of death and its volatile constituents may have many applications in forensic sciences. Domestic pigs are the most widely used human body analogues in forensic experiments, mainly due to ethical restrictions. Indeed, decomposition trials on human corpses are restricted in many countries worldwide. This article reports on the use of comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GCxGC-TOFMS) for thanatochemistry applications. A total of 832 VOCs released by a decaying pig carcass in terrestrial ecosystem, i.e. a forest biotope, were identified by GCxGC-TOFMS. These postmortem compounds belong to many kinds of chemical class, mainly oxygen compounds (alcohols, acids, ketones, aldehydes, esters), sulfur and nitrogen compounds, aromatic compounds such as phenolic molecules and hydrocarbons. The use of GCxGC-TOFMS in study of postmortem volatile compounds instead of conventional GC-MS was successful. PMID:22723918

  6. Multivariate Optimization for Extraction of Pyrethroids in Milk and Validation for GC-ECD and CG-MS/MS Analysis

    PubMed Central

    Zanchetti Meneghini, Leonardo; Rübensam, Gabriel; Claudino Bica, Vinicius; Ceccon, Amanda; Barreto, Fabiano; Flores Ferrão, Marco; Bergold, Ana Maria

    2014-01-01

    A simple and inexpensive method based on solvent extraction followed by low temperature clean-up was applied for determination of seven pyrethroids residues in bovine raw milk using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) and gas chromatography with electron-capture detector (GC-ECD). Sample extraction procedure was established through the evaluation of seven different extraction protocols, evaluated in terms of analyte recovery and cleanup efficiency. Sample preparation optimization was based on Doehlert design using fifteen runs with three different variables. Response surface methodologies and polynomial analysis were used to define the best extraction conditions. Method validation was carried out based on SANCO guide parameters and assessed by multivariate analysis. Method performance was considered satisfactory since mean recoveries were between 87% and 101% for three distinct concentrations. Accuracy and precision were lower than ±20%, and led to no significant differences (p < 0.05) between results obtained by GC-ECD and GC-MS/MS techniques. The method has been applied to routine analysis for determination of pyrethroid residues in bovine raw milk in the Brazilian National Residue Control Plan since 2013, in which a total of 50 samples were analyzed. PMID:25380457

  7. Coupling gas chromatography and electronic nose detection for detailed cigarette smoke aroma characterization.

    PubMed

    Rambla-Alegre, Maria; Tienpont, Bart; Mitsui, Kazuhisa; Masugi, Eri; Yoshimura, Yuta; Nagata, Hisanori; David, Frank; Sandra, Pat

    2014-10-24

    Aroma characterization of whole cigarette smoke samples using sensory panels or electronic nose (E-nose) devices is difficult due to the masking effect of major constituents and solvent used for the extraction step. On the other hand, GC in combination with olfactometry detection does not allow to study the delicate balance and synergetic effect of aroma solutes. To overcome these limitations a new instrumental set-up consisting of heart-cutting gas chromatography using a capillary flow technology based Deans switch and low thermal mass GC in combination with an electronic nose device is presented as an alternative to GC-olfactometry. This new hyphenated GC-E-nose configuration is used for the characterization of cigarette smoke aroma. The system allows the transfer, combination or omission of selected GC fractions before injection in the E-nose. Principal component analysis (PCA) and discriminant factor analysis (DFA) allowed clear visualizing of the differences among cigarette brands and classifying them independently of their nicotine content. Omission and perceptual interaction tests could also be carried out using this configuration. The results are promising and suggest that the GC-E-nose hyphenation is a good approach to measure the contribution level of individual compounds to the whole cigarette smoke. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Comparison of gas chromatography-combustion-mass spectrometry and gas chromatography-flame ionization detector for the determination of fatty acid methyl esters in biodiesel without specific standards.

    PubMed

    Sobrado, Laura Alonso; Freije-Carrelo, Laura; Moldovan, Mariella; Encinar, Jorge Ruiz; Alonso, J Ignacio García

    2016-07-29

    GC-FID has been effectively used as a universal quantification technique for volatile organic compounds for a long time. In most cases, the use of the ECN allows for quantification by GC-FID without external calibration using only the response of a single internal standard. In this paper we compare the performance characteristics of GC-FID with those of post-column (13)C Isotope Dilution GC-Combustion-MS for the absolute quantification of organic compounds without the need for individual standards. For this comparison we have selected the quantification of FAMEs in biodiesel. The selection of the right internal standard was critical for GC-FID even when ECN were considered. On the other hand, the nature of the internal standard was not relevant when GC-Combustion-MS was employed. The proposed method was validated with the analysis of the certified reference material SRM 2772 and comparative data was obtained on real biodiesel samples. The analysis of the SRM 2772 biodiesel provided recoveries in the range 100.6-103.5% and 96.4-103.6% for GC-combustion-MS and GC-FID, respectively. The detection limit for GC-combustion-MS was found to be 4.2ng compound/g of injected sample. In conclusion, the quantitative performance of GC-Combustion-MS compared satisfactorily with that of GC-FID constituting a viable alternative for the quantification of organic compounds without the need for individual standards. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Rapid identification of pork for halal authentication using the electronic nose and gas chromatography mass spectrometer with headspace analyzer.

    PubMed

    Nurjuliana, M; Che Man, Y B; Mat Hashim, D; Mohamed, A K S

    2011-08-01

    The volatile compounds of pork, other meats and meat products were studied using an electronic nose and gas chromatography mass spectrometer with headspace analyzer (GCMS-HS) for halal verification. The zNose™ was successfully employed for identification and differentiation of pork and pork sausages from beef, mutton and chicken meats and sausages which were achieved using a visual odor pattern called VaporPrint™, derived from the frequency of the surface acoustic wave (SAW) detector of the electronic nose. GCMS-HS was employed to separate and analyze the headspace gasses from samples into peaks corresponding to individual compounds for the purpose of identification. Principal component analysis (PCA) was applied for data interpretation. Analysis by PCA was able to cluster and discriminate pork from other types of meats and sausages. It was shown that PCA could provide a good separation of the samples with 67% of the total variance accounted by PC1. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Lipidomic analysis of glycerolipid and cholesteryl ester autooxidation products.

    PubMed

    Kuksis, Arnis; Suomela, Jukka-Pekka; Tarvainen, Marko; Kallio, Heikki

    2009-06-01

    Thin-layer chromatography (TLC), gas chromatography (GC), and liquid chromatography (LC) in combination with mass spectrometry (MS) have been adopted for the isolation and identification of oxolipids and for determining their functionality. TLC provides a rapid separation and access to most oxolipids as intact molecules and has recently been effectively interfaced with time-of-flight (TOF) MS (TOF-MS). GC with flame ionization (FI) (GC/FI) and electron impact (EI) MS (GC/EI-MS) has been extensively utilized in the analysis of isoprostanes and other low-molecular-weight oxolipids, although these methods require derivatization of the analytes. In contrast, LC with ultraviolet (UV) absorption (LC/UV) or evaporate light scattering detection (ELSD) (LC/ELSD) as well as electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) MS (LC/ESI-MS) or LC/APCI-MS has proven to be well suited for the analysis of intact oxolipids and their conjugates without or with minimal derivatization. Nevertheless, kit-based colorimetric and fluorescent procedures continue to serve as sensitive indicators of the presence of hydroperoxides and aldehydes.

  11. Chemical composition and biological activities of essential oils of Pinus patula.

    PubMed

    Amri, Ismail; Lamia, Hamrouni; Gargouri, Samia; Hanana, Mohsen; Mahfoudhia, Mariem; Fezzani, Tarek; Ezzeddine, Ferjani; Jamoussi, Bassem

    2011-10-01

    Essential oils isolated from needles of Pinus patula by hydrodistillation were analyzed by gas chromatography-flame ionization detection (GC-FID) and gas chromatography mass spectrometry (GC-MS). Thirty-eight compounds were identified, representing 98.3% of the total oil. The oil was rich in monoterpene hydrocarbons (62.4%), particularly alpha-pinene (35.2%) and beta-phellandrene (19.5%). The in vitro antifungal assay showed that P. patula oil significantly inhibited the growth of 9 plant pathogenic fungi. The oil, when tested on Sinapis arvensis, Lolium rigidum, Phalaris canariensis and Trifolium campestre, completely inhibited seed germination and seedling growth of all species. Our preliminary results showed that P. patula essential oil could be valorized for the control of weeds and fungal plant diseases.

  12. Determination of organochlorine pesticides in skins and leather by gas chromatography.

    PubMed

    Font, J; Marsal, A

    1998-06-19

    The simultaneous determination of residues of lindane (gamma-HCH) and 10 other organochlorine pesticides (OCPs) in skins and leather was carried out by gas chromatography (GC) with electron-capture detection (ECD). GC with mass spectrometric detection was used to identity confirmation. Samples were extracted with hexane. The extracts were concentrated, and cleaned up on a Florisil column. Dibromooctafluorobiphenyl was added as internal standard. Hide fortifications of 0.5 an d5.0 ppm yielded average lindane recoveries of 98% and 96%, respectively. OCPs was determined in 57 samples of skins purchased from American, European and African countries in 1996-1997. OCPs were not detected in any of the American and European samples. Residues of lindane were found in 56% of African samples.

  13. The constituents of essential oil in leaves of Karaj accession of Trigonella foenum graecum.

    PubMed

    Riasat, Mehrnaz; Jafari, Ali Ashraf; Bahmanzadegan, Atefeh; Hatami, Ahmad; Zareiyan, Faraneh

    2017-07-01

    The chemical composition of the essential oils of Karaj accession of Trigonella foenum graecum leaves was detected by hydro-distillation and analysed by gas chromatography (GC-FID) and gas chromatography-mass spectroscopy (GC-MS) apparatuses for first time. Thirty-six compounds representing 95.3% of the total components were identified. The patterns of the main compounds were (2E)-Hexenal (26.61%), n-Hexadecanoic acid (10.14%) and (E)-b-Ionone (7.99%). Other notable constituents were Thymol (4.79%), 6,10,14-trimethyl-2-Pentadecanone (4.59%), Carvacrol (3.40%), (E)-Nerolidol (3.32%) and (2E,6Z)-Nonadienal (3.30%). (2E)-Hexenal was found as the most dominant component in this study.

  14. Gamma ray degradation of electrolytes containing alkylcarbonate solvents and a lithium salt

    NASA Astrophysics Data System (ADS)

    Caillon-Caravanier, Magaly; Jones, Jennifer; Anouti, Mérièm; Montigny, Frédéric; Willmann, Patrick; David, Jean-Pierre; Soonckindt, Sabine; Lemordant, Daniel

    Lithium-ion batteries for space applications, such as satellites, are subjected to cosmic radiations, in particular, γ-irradiation. In this study, the effects of this radiation on electrolytes and their components used in the lithium-ion batteries are investigated. The conductivity and viscosity of the samples have been measured before and after the irradiation. The modifications are evaluated by spectral analyses such as Fourier transform infrared spectroscopy (FTIR), nuclear magnetic resonance spectroscopy (1H and 13C NMR), solid phase microextraction-gas chromatography (SPME-GC) and gas chromatography-mass spectroscopy (GC-MS). The experimental results show that only the samples containing vinylene carbonate and/or the lithium salt LiPF 6 are degraded by γ-radiation.

  15. An automated approach to detecting signals in electroantennogram data

    Treesearch

    D.H. Slone; B.T. Sullivan

    2007-01-01

    Coupled gas chromatography/electroantennographic detection (GC-EAD) is a widely used method for identifying insect olfactory stimulants present in mixtures of volatiles, and it can greatly accelerate the identification of insect semiochemicals. In GC-EAD, voltage changes across an insect's antenna are measured while the antenna is exposed to compounds eluting fi-...

  16. THE ROLE OF GC-MS AND LC-MS IN THE DISCOVERY OF DRINKING WATER DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    Gas chromatography-mass spectrometry (GC-MS) has played a pivotal role in the discovery of disinfection by-products (DBPs) in drinking water. DBPs are formed when disinfectants, such as chlorine, ozone, chlorine dioxide or chloramine, react with natural organic matter in the wate...

  17. Identification of sulphur volatiles and GC-olfactometry aroma profiling in two fresh tomato cultivars

    USDA-ARS?s Scientific Manuscript database

    Ten sulphur volatiles were observed in two Florida tomato cultivars (‘Tasti-Lee’ and ‘FL 47’) harvested at three maturity stages (breaker, turning, and pink) using gas chromatography with a pulsed flame photometric detector (GC-PFPD). Eight PFPD peaks were identified using retention values from auth...

  18. Fast Sampling Gas Chromatography (GC) System for Speciation in a Shock Tube

    DTIC Science & Technology

    2016-10-31

    capture similar ethylene decomposition rates for temperature-dependent shock experiments. (a) Papers published in peer-reviewed journals (N/A for none...3 GC Sampling System Validation Experiments ............................................................................... 5 Ethylene ...results for cold shock experiments, and both techniques capture similar ethylene decomposition rates for temperature-dependent shock experiments. Problem

  19. Mass spectrometric techniques for characterizing low-molecular-weight resins used as paint varnishes.

    PubMed

    Bonaduce, I; Colombini, M P; Degano, I; Di Girolamo, F; La Nasa, J; Modugno, F; Orsini, S

    2013-01-01

    The molecular structure of three low-molecular-weight resins used as paint varnishes has been characterized by use of an approach based on three different mass spectrometric techniques. We investigated the ketone resin MS2A, the aldehyde resin Laropal A81, and the hydrocarbon resin Regalrez 1094, now commonly used in restoration. To date, the molecular structures of these resins have not been completely elucidated. To improve current knowledge of the chemical composition of these materials, information obtained by gas chromatography-mass spectrometry (GC/MS), pyrolysis-gas chromatography-mass spectrometry (Py/GC/MS), and electrospray ionization mass spectrometry (ESI-Q-ToF) was combined. Analysis, in solution, of the whole polymeric fraction of the resins by flow-injection ESI-Q-ToF, and of the non-polymeric fraction by GC-MS, enabled us to identify previously unreported features of the polymer structures. In addition, the Py-GC/MS profiles that we obtained will help to enhance the databases currently available in the literature. The proposed approach can be extended to other low-molecular-weight resins used as varnishes in conservation.

  20. Heart-cutting two-dimensional gas chromatography in combination with isotope ratio mass spectrometry for the characterization of the wax fraction in plant material.

    PubMed

    Dumont, Emmie; Tienpont, Bart; Higashi, Nobukazu; Mitsui, Kazuhisa; Ochiai, Nobuo; Kanda, Hirooki; David, Frank; Sandra, Pat

    2013-11-22

    Gas chromatography coupled to isotope ratio mass spectrometry after on-line combustion (GC-C-IRMS) and high temperature conversion (GC-HTC-IRMS) is used for compound specific isotope ratio determination. This determination can only be performed successfully if the target solutes are fully resolved from other compounds. A new instrumental set-up consisting of heart-cutting two-dimensional GC based on capillary flow technology and a low thermal mass GC oven in combination with an isotope ratio mass spectrometer is presented. Capillary flow technology was also used in all column and interface connections for robust and leak-free operation. The new configuration was applied to the characterization of wax compounds in tobacco leaf and corresponding smoke samples. It is demonstrated that high accuracy is obtained, both in the determination of δ(13)C and δ(2)H values, allowing the study of biosynthesis and delivery mechanisms of naturally occurring compounds in tobacco. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. The simultaneous separation and determination of chloropropanols in soy sauce and other flavoring with gas chromatography-mass spectrometry in negative chemical and electron impact ionization modes.

    PubMed

    Xu, Xiaomin; Ren, Yiping; Wu, Pinggu; Han, Jianlong; Shen, Xianghong

    2006-02-01

    Both gas chromatography-mass spectrometry in electron ionization (GC-MS-EI) and negative chemical ionization (GC-MS-NCI) modes are reported in this paper for the simultaneous determination of 1,3-dichloropropan-2-ol (1,3-DCP), 2,3-dichloropropan-1-ol (2,3-DCP), 3-chloropropane-1,2-diol (3-MCPD) and 2-chloropropane-1,3-diol (2-MCPD) in soy sauce and other flavoring. D(5)-3-MCPD (for 3-MCPD and 2-MCPD) and d(5)-1,3-DCP (for 1,3-DCP and 2,3-DCP) were used as the deuterium isotopic labelled internal standards. The feasibility of using heptafluorobutyric anhydride modified with triethylamine (HFBA-Et(3)N) as a new derivatization reagent to replace heptafluorobutyrylimidazole (HFBI) is proposed. Liquid/liquid extraction with hexane was introduced for high lipid content samples. A small survey was carried out of soy sauces (103 samples) and instant noodles (45 samples) and the applicability of GC-MS-NCI and GC-MS-EI was assessed in these different matrices.

  2. Agroecosystem development of industrial fermentation waste -- characterization of aroma-active compounds from the cultivation medium of Lactobacillus brevis.

    PubMed

    Ono, Toshirou; Usami, Atsushi; Nakaya, Satoshi; Shinpuku, Hideto; Yonejima, Yasunori; Ikeda, Atsushi; Miyazawa, Mitsuo

    2015-01-01

    Volatile oils obtained from both the liquid medium after incubation (MAI) and liquid medium before incubation (MBI) during the cultivation process of Lactobacillus brevis were isolated by hydrodistillation (HD) and analyzed to determine the utility of the liquid waste. The composition of the volatile oils was analyzed by capillary gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). In total, 55 and 36 compounds were detected in the volatile oils from MAI (MAI oil) and MBI (MBI oil), respectively. The principle components of MAI oil were N-containing compounds, including 2,3-dimethylpyrazine (16, 37.1 %), methylpyrazine (4, 17.1 %). The important aroma-active compounds in the oils were detected by GC-Olfactometry (GC-O), and their intensity of aroma were measured by aroma extract dilution analysis (AEDA). Expressly, pyrazine compounds were determined as key aroma components; in particular, 2,5-dimethylpyrazine and 2,3-dimethylpyrazine were the most primary aroma-active compound in MAI oil. These results imply that the waste medium after incubation of L. brevis may be utilized as a source of volatile oils.

  3. Enzymatic digestion and selective quantification of underivatised delta-9-tetrahydrocannabinol and cocaine in human hair using gas chromatography-mass spectrometry.

    PubMed

    Breidi, Salah Eddine; Barker, James; Petróczi, Andrea; Naughton, Declan P

    2012-01-01

    Gas chromatography-mass spectrometric (GC-MS) methods for drug analysis routinely employ derivatising reagents. The aim of this paper was to develop a method for the analysis of two recreational drugs, delta-9-tetrahydrocannabinol (Δ(9)-THC) and cocaine in hair samples using GC-MS, without prior derivatisation, thus allowing the sample to be reanalysed in its original form. An enzymatic digestion technique was also developed. Ten hair samples, that were known positive for either Δ(9)-THC and/or cocaine, were enzymatically digested, extracted, and then analysed by GC-MS. All samples measured contained Δ(9)-THC and one sample contained cocaine. The limits of detection (LOD) and quantification (LOQ) were 0.02 ng/mg and 0.05 ng/mg, respectively, for cocaine and 0.015 ng/mg and 0.02 ng/mg, respectively, for Δ(9)-THC. The wide detection window, ease of direct analysis by GC-MS, lower detection limits of underivatised samples, and the stability of drugs using this technique may offer an improved method of analysis.

  4. Enzymatic Digestion and Selective Quantification of Underivatised Delta-9-Tetrahydrocannabinol and Cocaine in Human Hair Using Gas Chromatography-Mass Spectrometry

    PubMed Central

    Breidi, Salah Eddine; Barker, James; Petróczi, Andrea; Naughton, Declan P.

    2012-01-01

    Gas chromatography-mass spectrometric (GC-MS) methods for drug analysis routinely employ derivatising reagents. The aim of this paper was to develop a method for the analysis of two recreational drugs, delta-9-tetrahydrocannabinol (Δ9-THC) and cocaine in hair samples using GC-MS, without prior derivatisation, thus allowing the sample to be reanalysed in its original form. An enzymatic digestion technique was also developed. Ten hair samples, that were known positive for either Δ9-THC and/or cocaine, were enzymatically digested, extracted, and then analysed by GC-MS. All samples measured contained Δ9-THC and one sample contained cocaine. The limits of detection (LOD) and quantification (LOQ) were 0.02 ng/mg and 0.05 ng/mg, respectively, for cocaine and 0.015 ng/mg and 0.02 ng/mg, respectively, for Δ9-THC. The wide detection window, ease of direct analysis by GC-MS, lower detection limits of underivatised samples, and the stability of drugs using this technique may offer an improved method of analysis. PMID:22567573

  5. A study of the vaporization enthalpies of some 1-substituted imidazoles and pyrazoles by correlation-gas chromatography.

    PubMed

    Lipkind, Dmitry; Plienrasri, Chatchawat; Chickos, James S

    2010-12-23

    The vaporization enthalpies of 1-methyl-, 1-ethyl-, 1-phenyl-, and 1-benzylimidazole, 1-methyl- and 1-phenylpyrazole, and trans-azobenzene are evaluated by correlation-gas chromatography (C-GC) using a variety of azines and diazines as standards. The vaporization enthalpies obtained by C-GC when compared to literature values are approximately 14 kJ·mol(-1) smaller for the imidazoles and 6 kJ·mol(-1) smaller for the pyrazoles. The literature vaporization enthalpies of 1-methylpyrrole and 1-methylindole, two closely related compounds with one less nitrogen, are reproduced by C-GC. These results suggest that the magnitude of the intermolecular interactions present in 1-substituted imidazoles and pyrazoles are significantly larger than the those present in the reference compounds and greater than or equal in magnitude to the enhanced intermolecular interactions observed previously in aromatic 1,2-diazines. The vaporization enthalpy and vapor pressure of a trans-1,2-diazine, trans-azobenzene, measured by C-GC using similar standards reproduced the literature values within experimental error.

  6. Identification (GC and GC-MS) of unsaturated acetates in Elasmopalpus lignosellus and their biological activity (GC-EAD and EAG).

    PubMed

    Jham, Gulab N; da Silva, Alexsandro A; Lima, Eraldo R; Viana, Paulo

    2005-02-01

    Two insect colonies of Elasmopalpus lignosellus were reared in our laboratory, the first being initiated from pupae obtained from a cornfield in the region of Sete Lagoas, Minas Gerais and the second from a cornfield in the region of Goiânia, Goiás. From the two colonies, two extracts were prepared from the pheromone glands of virgin E. lignosellus females. The extract obtained from the first colony was designated as extract 1 while the extract obtained from the second colony was designated as extract 2. Extract 1 was analyzed by gas chromatography-mass spectrometry (GC-MS) with (Z)-9-hexadecenyl acetate [(Z)-9-HDA] and (Z)-11-hexadecenyl acetate [(Z)-11-HDA] being identified and confirmed by the formation of DMDS derivatives. In addition, a third acetate, which could be either (E)-8-hexadecenyl acetate [(E)-8-HDA] or (E)-9-hexadecenyl acetate [(E)-9-HDA] was detected by GC-MS. Extract 2 was analyzed by gas chromatography (GC) and gas chromatography-electroannetography (GC-EAD) revealing the presence of (Z)-11-HDA and (Z)-9-TDA. In addition, the same compounds elicited a response with the E. lignosellus male antenna obtained from the second insect colony. Electroantennography (EAG) screening with the male E. lignosellus antenna (obtained from the second insect colony) was conducted with the 23 possible tetradecenyl acetates (TDA) and 22 hexadecenyl acetates (HDA) as standards. Out of the 23 TDA isomers evaluated, only (Z)-9-TDA elicited a response and out of the 22 HDA [(Z) and (E) isomers gamma2 to delta13] evaluated only (Z)-11-HDA elicited a response. The acetate compositions of two extracts obtained from insects originating from the two states (Minas Gerais and Goiás) of Brazil were different from one another as well as from that obtained from insects in Tifton, GA, USA. The bioactivity data (GC-EAD) of the extract 2 differed from those reported for the Tifton, GA, USA population. These data suggest polymorphism in relation to the insect populations found in Brazil and in the USA. The possibility of the existence of an E. lignosellus sub-species cannot be ruled out.

  7. [Analysis of aromatic hydrocarbons in cracking products of jet fuel by comprehensive two-dimensional gas chromatography-mass spectrometry].

    PubMed

    Li, Haijing; Zhang, Xiangwen

    2017-08-08

    As coking precursors, aromatic hydrocarbons have an effect on the cracking stability of fuels. A method for identifying and quantitating aromatics in the supercritical cracking products of jet fuel was established by comprehensive two-dimensional gas chromatography coupled with mass spectrometry (GC×GC-MS). The effects of main chromatographic conditions such as initial oven temperature and modulation period on the separation of supercritical cracking products were studied. The method has good separation ability for polycyclic aromatic hydrocarbons (PAH) isomers. A total of 27 aromatics, including monocyclic aromatic hydrocarbons, bicyclic aromatic hydrocarbons, tricyclic aromatic hydrocarbons, tetracyclic aromatic hydrocarbons, etc., were identified based on standard mass spectra, the retention times of standards and literature reports. Moreover, the corresponding quantitative determination was achieved by external standard method of GC×GC-FID. The results showed that the contents of aromatics increased with the increase of gas yield. When gas yield reached 22%, the bicyclic aromatic hydrocarbons began to produce, and their contents increased exponentially with the increase of gas yield. Compared with the traditional GC-MS, the method has better separation and qualitative ability, and can be applied to the separation of complex samples and qualitative and quantitative analyses of cracking products.

  8. Investigations on the emission of fragrance allergens from scented toys by means of headspace solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Masuck, Ines; Hutzler, Christoph; Luch, Andreas

    2010-04-30

    In the revised European toy safety directive 2009/48/EC the application of fragrance allergens in children's toys is restricted. The focus of the present work lies on the instrumental analytics of 13 banned fragrance allergens, as well as on 11 fragrance allergens that require declaration when concentrations surpass 100 microg per gram material. Applying a mixture of ethyl acetate and toluene solid/liquid extraction was performed prior to quantitative analysis of mass contents of fragrances in scented toys. In addition, an easy-to-perform method for the determination of emitted fragrances at 23 degrees C (handling conditions) or at 40 degrees C (worst case scenario) has been worked out to allow for the evaluation of potential risks originating from inhalation of these compounds during handling of or playing with toys. For this purpose a headspace solid-phase microextraction (HS-SPME) technique was developed and coupled to subsequent gas chromatography-mass spectrometry (GC-MS) analysis. Fragrance allergens were adsorbed (extracted) from the gas phase onto an 85 microm polyacrylate fiber while incubating pieces of the scented toys in sealed headspace vials at 23 degrees C and 40 degrees C. Quantification of compounds was performed via external calibration. The newly developed headspace method was subsequently applied to five perfumed toys. As expected, the emission of fragrance allergens from scented toys depends on the temperature and on the content of fragrance allergens present in those samples. In particular at conditions mimicking worst case (40 degrees C), fragrance allergens in toys may pose a risk to children since considerable amounts of compound might be absorbed by lung tissue via breathing of contaminated air. 2010 Elsevier B.V. All rights reserved.

  9. High-resolution gas chromatography/mass spectrometry method for characterization and quantitative analysis of ginkgolic acids in Ginkgo biloba plants, extracts, and dietary supplements.

    PubMed

    Wang, Mei; Zhao, Jianping; Avula, Bharathi; Wang, Yan-Hong; Avonto, Cristina; Chittiboyina, Amar G; Wylie, Philip L; Parcher, Jon F; Khan, Ikhlas A

    2014-12-17

    A high-resolution gas chromatography/mass spectrometry (GC/MS) with selected ion monitor method focusing on the characterization and quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba L. plant materials, extracts, and commercial products was developed and validated. The method involved sample extraction with (1:1) methanol and 10% formic acid, liquid-liquid extraction with n-hexane, and derivatization with trimethylsulfonium hydroxide (TMSH). Separation of two saturated (C13:0 and C15:0) and six unsaturated ginkgolic acid methyl esters with different positional double bonds (C15:1 Δ8 and Δ10, C17:1 Δ8, Δ10, and Δ12, and C17:2) was achieved on a very polar (88% cyanopropyl) aryl-polysiloxane HP-88 capillary GC column. The double bond positions in the GAs were determined by ozonolysis. The developed GC/MS method was validated according to ICH guidelines, and the quantitation results were verified by comparison with a standard high-performance liquid chromatography method. Nineteen G. biloba authenticated and commercial plant samples and 21 dietary supplements purported to contain G. biloba leaf extracts were analyzed. Finally, the presence of the marker compounds, terpene trilactones and flavonol glycosides for Ginkgo biloba in the dietary supplements was determined by UHPLC/MS and used to confirm the presence of G. biloba leaf extracts in all of the botanical dietary supplements.

  10. Synthesis and Development of Porous Polymeric Column Packing and Microchip Detectors for GC Analysis of Extraterrestrial Atmospheres

    NASA Technical Reports Server (NTRS)

    Shen, Thomas C.

    1999-01-01

    This report summarizes the last nine years research accomplishments under Cooperative Agreement NCC2-650 between NASA, Ames Research Center and SETI Institute. Four Major research tasks are conducted: 1. Gas chromatography column development. 2. Pyrosensor development. 3. Micro-machining gas chromatography instrument development. 4. Amino acid analysis and high molecular weight polyamino acid synthesis under prebiotic conditions. The following describes these results.

  11. Low-molecular-weight model study of peroxide cross-linking of ethylene-propylene-diene rubber using gas chromatography and mass spectrometry II. Addition and combination reactions.

    PubMed

    Peters, R; van Duin, M; Tonoli, D; Kwakkenbos, G; Mengerink, Y; van Benthem, R A T M; de Koster, C G; Schoenmakers, P J; van der Wal, Sj

    2008-08-08

    The dicumyl-peroxide-initiated addition and combination reactions of mixtures of alkanes (n-octane, n-decane) and alkenes [5,6-dihydrodicyclopentadiene (DCPDH), 5-ethylidene-2-norbornane (ENBH) and 5-vinylidene-2-norbornane (VNBH)] were studied to mimic the peroxide cross-linking reactions of terpolymerised ethylene, propylene and a diene monomer (EPDM). The reaction products of the mixtures were separated by both gas chromatography (GC) and comprehensive two-dimensional gas chromatography (GCxGC). The separated compounds were identified from their mass spectra and their GC and GCxGC elution pattern. Quantification of the various alkyl/alkyl, alkyl/allyl and allyl/allyl combination products shows that allylic-radicals comprise approximately 60% of the substrate radicals formed. The total concentration of the products formed by combination is found to be independent of the concentration and the type of alkene. The total concentration of the products formed by addition to the alkene increases with increasing concentration of alkene. In addition, the total concentration of the formed addition products depends strongly on the type of the alkene used, viz. VNBH>ENBH approximately DCPDH, which is a consequence of differences in steric hindrance of the unsaturation. The peroxide curing efficiency, defined as the number of moles of cross-linked products formed per mol of peroxide, is 173% using 9% (w/w) 5-vinylidene-2-norbornane (VNBH). This indicates that the addition reaction is recurrent. All these findings are consistent with experimental studies on peroxide curing of EPDM rubber. In addition, the present results provide more-detailed structural information, increasing the understanding of the mechanism of peroxide curing of EPDM. The described approach to use low-molecular-weight model compounds followed by GC-mass spectrometry (MS) and GCxGC-MS analysis is proven to be a very powerful tool to study the cross-linking of EPDM.

  12. Geochemical character and origin of oils in Ordovician reservoir rock, Illinois and Indiana, USA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guthrie, J.M.; Pratt, L.M.

    1995-11-01

    Twenty-three oils produced from reservoirs within the Ordovician Galena Group (Trenton equivalent) and one oil from the Mississippian Ste. Genevieve Limestone in the Illinois and Indiana portions of the Illinois basin are characterized. Two end-member oil groups (1) and (2) and one intermediate group (1A) are identified using conventional carbon isotopic analysis of whole and fractionated oils, gas chromatography (GC) of saturated hydrocarbon fractions, isotope-ratio-monitoring gas chromatography/mass spectrometry (irm-GC/MS) of n-alkanes ranging from C{sub 15} to C{sub 25}, and gas chromatography/mass spectrometry (GC/MS) of the aromatic hydrocarbon fractions. Group 1 is characterized by high odd-carbon predominance in mid-chain n-alkanes (C{submore » 15}-C{sub 19}), low abundance Of C{sub 20+}, n-alkanes, and an absence of pristane and phytane. Group IA is characterized by slightly lower odd-carbon predominance of mid-chain n-alkanes, greater abundance of C{sub 20+} n-alkanes compared to group 1, and no pristane and phytane. Conventional correlations of oil to source rock based on carbon isotopic-type curves and hopane (m/z 191) and sterane (m/z 217) distributions are of limited use in distinguishing Ordovician-reservoired oil groups and determining their origin. Oil to source rock correlations using the distribution and carbon isotopic composition of n-alkanes and the m/z 133 chromatograms of n-alkylarenes show that groups 1 and 1A originated from strata of the Upper Ordovician Galena Group. Group 2 either originated solely from the Upper Ordovician Maquoketa Group or from a mixture of oils generated from the Maquoketa Group and the Galena Group. The Mississippian-reservoired oil most likely originated from the Devonian New Albany Group. The use of GC, irm-GC/MS, and GC/MS illustrates the value of integrated molecular and isotopic approaches for correlating oil groups with source rocks.« less

  13. DETERMINATION OF INTERFERING TRIAZINE DEGRADATION PRODUCTS BY GAS CHROMATOGRAPHY-ION TRAP MASS SPECTROMETRY

    EPA Science Inventory

    Deethyl atrazine (DEA), along with other triazine degradation products, has been added to the US Environmental Protection Agency's Drinking Water Contaminant Candidate List (CCL). In its gas chromatographic (GC) analysis, deethyl atrazine, a degradation product of atrazine, can ...

  14. DEMONSTRATION BULLETIN: FIELD ANALYTICAL SCREENING PROGRAM: PCB METHOD - U.S. ENVIRONMENTAL PROTECTION AGENCY

    EPA Science Inventory

    The field analytical screening program (FASP) polychlorinated biphenyl (PCB) method uses a temperature-programmable gas chromatograph (GC) equipped with an electron capture detector (ECD) to identify and quantify PCBs. Gas chromatography is an EPA-approved method for determi...

  15. Analysis of poly-beta-hydroxybutyrate in environmental samples by GC-MS/MS.

    PubMed

    Elhottová, D; Tríska, J; Petersen, S O; Santrůcková, H

    2000-05-01

    Application of gas chromatography-mass spectrometry (GC-MS) can significantly improve trace analyses of compounds in complex matrices from natural environments compared to gas chromatography only. A GC-MS/MS technique for determination of poly-beta-hydroxybutyrate (PHB), a bacterial storage compound, has been developed and used for analysis of two soils stored for up to 319 d, fresh samples of sewage sludge, as well as a pure culture of Bacillus megaterium. Specific derivatization of beta-hydroxybutyrate (3-OH C4:0) PHB monomer units by N-tert-butyl-dimethylsilyl-N-methyltrifluoracetamide (MTBSTFA) improved chromatographic and mass spectrometric properties of the analyte. The diagnostic fragmentation scheme of the derivates tert-butyldimethylsilyl ester and ether of beta-hydroxybutyric acid (MTBSTFA-HB) essential for the PHB identification was shown. The ion trap MS was used, therefore the scan gave the best sensitivity and with MS/MS the noise decreased, so the S/N was better and also with second fragmentation the amount of ions increased compared to SIM. The detection limit for MTBSTFA-HB by GC-MS/MS was about 10(-13) g microL(-1) of injected volume, while by GC (FID) and GC-MS (scan) it was around 10(-10) g microL(-1) of injected volume. Sensitivity of GC-MS/MS measurements of PHB in arable soil and activated sludge samples was down to 10 pg of PHB g(-1) dry matter. Comparison of MTBSTFA-HB detection in natural soil sample by GC (FID), GC-MS (scan) and by GC-MS/MS demonstrated potentials and limitations of the individual measurement techniques.

  16. Evaluation of automated sample preparation, retention time locked gas chromatography-mass spectrometry and data analysis methods for the metabolomic study of Arabidopsis species.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Rumpel, Klaus; Dugardeyn, Jasper; Van Der Straeten, Dominique; Xu, Guowang; Sandra, Pat

    2011-05-27

    In this paper, automated sample preparation, retention time locked gas chromatography-mass spectrometry (GC-MS) and data analysis methods for the metabolomics study were evaluated. A miniaturized and automated derivatisation method using sequential oximation and silylation was applied to a polar extract of 4 types (2 types×2 ages) of Arabidopsis thaliana, a popular model organism often used in plant sciences and genetics. Automation of the derivatisation process offers excellent repeatability, and the time between sample preparation and analysis was short and constant, reducing artifact formation. Retention time locked (RTL) gas chromatography-mass spectrometry was used, resulting in reproducible retention times and GC-MS profiles. Two approaches were used for data analysis. XCMS followed by principal component analysis (approach 1) and AMDIS deconvolution combined with a commercially available program (Mass Profiler Professional) followed by principal component analysis (approach 2) were compared. Several features that were up- or down-regulated in the different types were detected. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. 76 FR 55804 - Dicamba; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-09

    ... Considerations A. Analytical Enforcement Methodology Adequate enforcement methodologies, Methods I and II--gas chromatography with electron capture detection (GC/ECD), are available to enforce the tolerance expression. The...

  18. Analysis of waterborne paints by gas chromatography-mass spectrometry with a temperature-programmable pyrolyzer.

    PubMed

    Nakamura, S; Takino, M; Daishima, S

    2001-04-06

    Gas chromatography-mass spectrometry (GC-MS) with a temperature-programmable pyrolyzer was used for the analysis of waterborne paints. Evolved gas analysis (EGA) profiles of the waterborne paints were obtained by this temperature-programmed pyrolysis directly coupled with MS via a deactivated metal capillary tube. The EGA profile suggested the optimal thermal desorption conditions for solvents and additives and the subsequent optimal pyrolysis temperature for the remaining polymeric material. Polymers were identified from pyrograms with the assistance of a new polymer library. The solvents were identified from the electron ionization mass spectra with the corresponding chemical ionization mass spectra. The additive was identified as zinc pyrithione by comparison with authentic standard. Zinc pyrithione cannot be analyzed by GC-MS as it is. However, the thermal decomposition products of zinc pyrithione could be detected. The information on the decomposition temperature and products was useful for the identification of the original compound.

  19. Environmental assessment of a firetube boiler firing coal/oil/water mixtures. Volume 2. Data supplement. Final report, February 1981-November 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRosier, R.

    1984-09-01

    This volume is a compendium of detailed emission and test data from field tests of a firetube industrial boiler burning a coal/oil/water (COW) mixture. The boiler was tested while burning COW fuel, and COW with soda ash added (COW+SA) to serve as an SO/sub 2/ sorbent. The test data include: preliminary equipment calibration data, boiler operating data for both tests, fuel analysis results, and complete flue gas emission measurement and laboratory analysis results. Flue gas emission measurements included: continuous monitoring for criteria gas pollutants; gas chromatography (GC) of gas grab samples for volatile organics (C1-C6); EPA Method 5 for particulate;more » controlled condensation system for SO2 emissions; and source assessment sampling system (SASS) for total organics in two boiling point ranges (100 to 300 C and > 300 C), organic compound category information using infrared spectrometry (IR) and low resolution mass spectrometry (LRMS), specific quantitation of the semivolatile organic priority pollutants using gas chromatography/mass spectrometry (GC/MS), liquid chromatography (LC) separation of organic extracts into seven polarity fractions with total organic and IR analyses of eluted fractions, flue gas concentrations of trace elements by spark source mass spectrometry (SSMS) and atomic absorption spectroscopy (AAS), and biological assays of organic extracts.« less

  20. Automated two-dimensional interface for capillary gas chromatography

    DOEpatents

    Strunk, M.R.; Bechtold, W.E.

    1996-02-20

    A multidimensional gas chromatograph (GC) system is disclosed which has wide bore capillary and narrow bore capillary GC columns in series and has a novel system interface. Heart cuts from a high flow rate sample, separated by a wide bore GC column, are collected and directed to a narrow bore GC column with carrier gas injected at a lower flow compatible with a mass spectrometer. A bimodal six-way valve is connected with the wide bore GC column outlet and a bimodal four-way valve is connected with the narrow bore GC column inlet. A trapping and retaining circuit with a cold trap is connected with the six-way valve and a transfer circuit interconnects the two valves. The six-way valve is manipulated between first and second mode positions to collect analyte, and the four-way valve is manipulated between third and fourth mode positions to allow carrier gas to sweep analyte from a deactivated cold trap, through the transfer circuit, and then to the narrow bore GC capillary column for separation and subsequent analysis by a mass spectrometer. Rotary valves have substantially the same bore width as their associated columns to minimize flow irregularities and resulting sample peak deterioration. The rotary valves are heated separately from the GC columns to avoid temperature lag and resulting sample deterioration. 3 figs.

Top