Sample records for gas phase chemiluminescence

  1. Plant Chemiluminescence

    PubMed Central

    Abeles, Fred B.; Leather, Gerald R.; Forrence, Leonard E.

    1978-01-01

    Light production by plants was confirmed by measuring chemiluminescence from root and stem tissue of peas (Pisum sativum), beans (Phaseolus vulgaris), and corn (Zea mays) in a modified scintillation spectrophotometer. Chemiluminescence was inhibited by treating pea roots with boiling ethanol or by placing them in a N2 gas phase. Chemiluminescence was increased by an O2 gas phase or by the addition of luminol. NaN3 and NaCN blocked both in vitro and in vivo chemiluminescence. It is postulated that the source of light is the hydrogen peroxide-peroxidase enzyme system. It is known that this system is responsible for chemiluminescence in leukocytes and it seems likely that a similar system occurs in plants. PMID:16660587

  2. Review of Federal Reference Method for Ozone: Nitric Oxide-Chemiluminescence

    EPA Science Inventory

    •The proposed new FRM measurement principle for ozone is based on quantitative measurement of the chemiluminescence emission from the gas-phase reaction of ozone in an air sample with nitric oxide (NO).•The chemiluminescence from the NO-O3 reaction (with excess NO) is p...

  3. The Chemiluminescence of Organometallic Compounds

    NASA Astrophysics Data System (ADS)

    Tolstikov, Genrikh A.; Bulgakov, Ramil G.; Kazakov, Valeri P.

    1985-11-01

    Studies on the liquid-phase and gas-phase reactions of organometallic compounds accompanied by the emission of light are described systematically and discussed. The influence of the magnetic field on the chemiluminescence of Grignard reagents and the study of the electrochemiluminescence of solutions of organometallic compounds are examined. The ways leading to further development of the field of the chemiluminescence of organometallic compounds and certain possible applications of the phenomenon in the monitoring of industrial processes are discussed. The bibliography includes 80 references.

  4. Evaluation and Comparison of Chemiluminescence and UV Photometric Methods for Measuring Ozone Concentrations in Ambient Air

    EPA Science Inventory

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O3) that may be p...

  5. Gas-phase chemiluminescent reactions of ozone with monoterpenes

    NASA Astrophysics Data System (ADS)

    Arora, P. K.; Chatha, J. P. S.; Vohra, K. G.

    1983-08-01

    Chemiluminescent reactions of ozone with monoterpenes such as linallol, geraniol, d-limonene and α-pinene have been studied in the gas phase at low pressures. Methylglyoxal phosphorescence has been observed in the first two reactions. Emissions from HCHO( 1A 2) and glyoxal ( 3A u) are observed in the reaction of ozone with d-limonene and formation of excited glyoxal is found to be first order in ozone. The reaction of ozone with β-pinene gives rise to emission from a α-dicarbonyl compound and this is found to be first order in ozone. The mechanisms for the formation of excited species are proposed.

  6. Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

    NASA Technical Reports Server (NTRS)

    Dunham, A. J.; Barkley, R. M.; Sievers, R. E.; Clarkson, T. W. (Principal Investigator)

    1995-01-01

    An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

  7. Analyzer for measurement of nitrogen oxide concentration by ozone content reduction in gas using solid state chemiluminescent sensor

    NASA Astrophysics Data System (ADS)

    Chelibanov, V. P.; Ishanin, G. G.; Isaev, L. N.

    2014-05-01

    Role of nitrogen oxide in ambient air is described and analyzed. New method of nitrogen oxide concentration measurement in gas phase is suggested based on ozone concentration measurement with titration by nitrogen oxide. Research of chemiluminescent sensor composition is carried out on experimental stand. The sensor produced on the base of solid state non-activated chemiluminescent composition is applied as ozone sensor. Composition is put on the surface of polymer matrix with developed surface. Sensor compositions includes gallic acid with addition of rodamine-6G. Model of interaction process between sensor composition and ozone has been developed, main products appeared during reaction are identified. The product determining the speed of luminescense appearance is found. This product belongs to quinone class. Then new structure of chemiluminescent composition was suggested, with absence of activation period and with high stability of operation. Experimental model of gas analyzer was constructed and operation algorithm was developed. It was demonstrated that developed NO measuring instrument would be applied for monitoring purposes of ambient air. This work was partially financially supported by Government of Russian Federation, Grant 074-U01

  8. On use of CO{sub 2} chemiluminescence for combustion metrics in natural gas fired reciprocating engines.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, S. B.; Bihari, B.; Biruduganti, M.

    Flame chemiluminescence is widely acknowledged to be an indicator of heat release rate in premixed turbulent flames that are representative of gas turbine combustion. Though heat release rate is an important metric for evaluating combustion strategies in reciprocating engine systems, its correlation with flame chemiluminescence is not well studied. To address this gap an experimental study was carried out in a single-cylinder natural gas fired reciprocating engine that could simulate turbocharged conditions with exhaust gas recirculation. Crank angle resolved spectra (266-795 nm) of flame luminosity were measured for various operational conditions by varying the ignition timing for MBT conditions andmore » by holding the speed at 1800 rpm and Brake Mean effective Pressure (BMEP) at 12 bar. The effect of dilution on CO*{sub 2}chemiluminescence intensities was studied, by varying the global equivalence ratio (0.6-1.0) and by varying the exhaust gas recirculation rate. It was attempted to relate the measured chemiluminescence intensities to thermodynamic metrics of importance to engine research -- in-cylinder bulk gas temperature and heat release rate (HRR) calculated from measured cylinder pressure signals. The peak of the measured CO*{sub 2} chemiluminescence intensities coincided with peak pressures within {+-}2 CAD for all test conditions. For each combustion cycle, the peaks of heat release rate, spectral intensity and temperature occurred in that sequence, well separated temporally. The peak heat release rates preceded the peak chemiluminescent emissions by 3.8-9.5 CAD, whereas the peak temperatures trailed by 5.8-15.6 CAD. Such a temporal separation precludes correlations on a crank-angle resolved basis. However, the peak cycle heat release rates and to a lesser extent the peak cycle temperatures correlated well with the chemiluminescent emission from CO*{sub 2}. Such observations point towards the potential use of flame chemiluminescence to monitor peak bulk gas temperatures as well as peak heat release rates in natural gas fired reciprocating engines.« less

  9. Flow injection gas chromatography with sulfur chemiluminescence detection for the analysis of total sulfur in complex hydrocarbon matrixes.

    PubMed

    Hua, Yujuan; Hawryluk, Myron; Gras, Ronda; Shearer, Randall; Luong, Jim

    2018-01-01

    A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual-plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample-to-sample time <2 min. The high degree of selectivity and sensitivity toward sulfur compounds of the detector offers the ability to measure low sulfur levels with a detection limit in the range of 20 ppb w/w S. The equimolar response characteristic of the detector allows the quantitation of unknown sulfur compounds and simplifies the calibration process. Response is linear over a concentration range of five orders of magnitude, with a high degree of repeatability. The detector's lack of response to hydrocarbons enables direct analysis without the need for time-consuming sample preparation and chromatographic separation processes. This flow injection-based sulfur chemiluminescence detection technique is ideal for fast analysis or trace sulfur analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Nitramine Propellant Ignition and Combustion Research: New Tools and New Directions

    DTIC Science & Technology

    1989-02-01

    promising innovation for the application of laser diagnostics to combustion studies is the use of planar imaging techniques. 13 This allows the...A.M. and Trott , W.M., J. de Physique 48, Colloq. C4, 179-188 (1987) 96. Fontijin, A., Ed. "Gas-Phase Chemiluminescence and Chemi-lonization," North

  11. Simplified ozone detection by chemiluminescence

    NASA Technical Reports Server (NTRS)

    Conway, E. J.; Rogowski, R. S.; Richards, R. R.

    1977-01-01

    Ozone is detected by film coated with solid, such as rubrene, that reacts with ozone to degree proportional to concentration in sample gas. Gas flow is stopped, and film is heated to produce light (chemiluminescence) in proportion to amount of reacted material on sensor.

  12. Performance of the Proposed New Federal Reference Methods for Measuring Ozone Concentrations in Ambient Air

    EPA Science Inventory

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air, described in EPA regulations at 40 CFR Part 50, Appendix D, is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O

  13. Fluorine-Induced Chemiluminescence Detection of Biologically Methylated Tellurium, Selenium, and Sulfur Compounds and Methyldithiocarbhydrazide as a Formaldehyde Derivatization Reagent

    NASA Astrophysics Data System (ADS)

    Chasteen, Thomas Girard

    1990-01-01

    The first part of this dissertation describes capillary chromatography coupled to a fluorine-induced chemiluminescence detector as a sensitive method by which biologically methylated metalloids can be determined in the presence of high concentrations of potentially interfering molecules. With a wide linear range and excellent sensitivity, this method was applied to the detection of dimethyl selenide (DMSe), dimethyl diselenide (DMDSe), and dimethyl telluride (DMTe), often found in biological environments in the presence of interfering methylated sulfur gases, such as methanethiol, dimethyl sulfide, dimethyl disulfide, and dimethyl trisulfide. Detection limits for DMSe, DMDSe, and DMTe were 30, 9, and 7 picograms, respectively. This DMTe detection limit is the lowest reported to date for a volatile tellurium gas. A variety of selenium-resistant bacteria emitted mixtures of methylated sulfur/selenium gases when dosed with inorganic selenium salts in the presence of sulfur containing growth media. One of the gases detected was dimethyl selenenyl sulfide, CH_3SeSCH _3, reported here for the first time in headspace above microorganisms. In addition, this detector responded to reduced phosphorus compounds such as phosphine. The detection limit for this compound was 2.8 picograms. Detection limits for alkylated phosphines trimethyl and triethyl phosphine were 0.5 and 17 picograms respectively, based on the relative response of these compounds compared to dimethyl sulfide. This method can be used for the simultaneous determination of methylated sulfur, selenium, tellurium compounds found in biological systems. Part II of this dissertation describes work with methyldithiocarbhydrazide, a compound that has been synthesized for use as a derivatization reagent to capture formaldehyde in the gas phase. Chosen for its ability to react in a manner similar to 2,4-dinitrophenylhydrazine, this molecule was selected based on two structural characteristics: a hydrazine tag to react with and thereby capture carbonyls and a methyl sulfide group to allow for sensitive detection by fluorine-induced chemiluminescence. Although in the final analysis methyldithiocarbohydrazide failed as a successful means by which formaldehyde can be determined using gas chromatography in conjunction with fluorine-induced chemiluminescence, it did successfully derivatize formaldehyde in both solution and the gas phase without the need for low pH conditions.

  14. An intercomparison of five ammonia measurement techniques

    NASA Technical Reports Server (NTRS)

    Williams, E. J.; Sandholm, S. T.; Bradshaw, J. D.; Schendel, J. S.; Langford, A. O.; Quinn, P. K.; Lebel, P. J.; Vay, S. A.; Roberts, P. D.; Norton, R. B.

    1992-01-01

    Results obtained from five techniques for measuring gas-phase ammonia at low concentration in the atmosphere are compared. These methods are: (1) a photofragmentation/laser-induced fluorescence (PF/LIF) instrument; (2) a molybdenum oxide annular denuder sampling/chemiluminescence detection technique; (3) a tungsten oxide denuder sampling/chemiluminescence detection system; (4) a citric-acid-coated denuder sampling/ion chromatographic analysis (CAD/IC) method; and (5) an oxalic-acid-coated filter pack sampling/colorimetric analysis method. It was found that two of the techniques, the PF/LIF and the CAD/IC methods, measured approximately 90 percent of the calculated ammonia added in the spiking tests and agreed very well with each other in the ambient measurements.

  15. DEVELOPMENT OF AN IMPROVED DETECTOR FOR USE WITH A GAS CHROMATOGRAPH TO MEASURE NO2 AND PAN IN THE ATMOSPHERE - PHASE I

    EPA Science Inventory

    Although nitrogen dioxide (NO2) is a priority pollutant, the Federal Reference Method is based on the chemiluminescent measurement of nitric oxide (NO) with the assumption that NO2 is the difference between nitrogen oxides (NOx) reduced to NO w...

  16. A comparison of flame ionization and ozone chemiluminescence for the determination of atmospheric hydrocarbons.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marley, N. A.; Gaffney, J. S.; Environmental Research

    A reactive hydrocarbon analyzer has been constructed on the basis of chemiluminescence reaction with ozone. This detector is designed to operate at varying temperatures which take advantage of the different rates of reaction of the hydrocarbon classes with ozone to yield a measure of their atmospheric reactivity. When operated at high temperatures (170 C), all hydrocarbons will give a chemiluminescence signal. Reported here is a direct comparison of the ozone chemiluminescent detector (operated at a temperature of 170 C) with a flame ionization detector. This comparison was accomplished by connecting a capillary gas chromatograph to each of the two detectorsmore » by means of a switching valve. Twenty-seven compounds representing alkanes, alkenes, aromatics, and oxygenated hydrocarbons (aldehydes, ketones, alcohols, and ethers) were studied. For the compounds studied, analytical sensitivities were 10-1000 times better for the chemiluminescence detector. The results of this comparison indicate that the response of the chemiluminescent detector at 170 C correlates with a total carbon detector (flame ionization detection) and that total response is a measure of total carbon in the sample. The chemiluminescent system will be very useful for gas chromatographic detection of atmospheric hydrocarbons, particularly of oxygenates in complex mixtures.« less

  17. NO2 measurement by chemiluminescence

    NASA Technical Reports Server (NTRS)

    Conway, E. J.; Rogowski, R. S.; Richards, R. R.

    1979-01-01

    Compact device monitors specific chemiluminescent reaction of heated solid material such as 3,5 diaminobezoic or polyvinyl alcohol after contact with gas sample to detect and quantify nitrogen dioxide concentration.

  18. Trace gas emissions from biomass burning in tropical Australian savannas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurst, D.F.; Griffith, D.W.T.; Cook, G.D.

    1994-08-20

    The trace gas emissions of biomass burning was measured during the 1991 and 1992 dry seasons (April through October) at the Kapalga Research Station in Kakadu National Park, Northern Territory, Australia. Over 100 smoke samples from savannah fires were collected, from the ground and from aircraft flying at 50 to 700 meters above the fires. The samples were analyzed for carbon dioxide, carbon monoxide, nitrous oxides, and other carbon and nitrogen compounds using gas phase Fourier transform infrared (FTIR) spectroscopy, matrix isolation FTIR spectroscopy, and chemiluminescence techniques. This paper describes the results of the gas analyses and discusses the potentialmore » impacts of these gases on regional atmospheric chemistry.49 refs., 4 figs., 7 tabs.« less

  19. Experience with novel technologies for direct measurement of atmospheric NO2

    NASA Astrophysics Data System (ADS)

    Hueglin, Christoph; Hundt, Morten; Mueller, Michael; Schwarzenbach, Beat; Tuzson, Bela; Emmenegger, Lukas

    2017-04-01

    Nitrogen dioxide (NO2) is an air pollutant that has a large impact on human health and ecosystems, and it plays a key role in the formation of ozone and secondary particulate matter. Consequently, legal limit values for NO2 are set in the EU and elsewhere, and atmospheric observation networks typically include NO2 in their measurement programmes. Atmospheric NO2 is principally measured by chemiluminescence detection, an indirect measurement technique that requires conversion of NO2 into nitrogen monoxide (NO) and finally calculation of NO2 from the difference between total nitrogen oxides (NOx) and NO. Consequently, NO2 measurements with the chemiluminescence method have a relatively high measurement uncertainty and can be biased depending on the selectivity of the applied NO2 conversion method. In the past years, technologies for direct and selective measurement of NO2 have become available, e.g. cavity attenuated phase shift spectroscopy (CAPS), cavity enhanced laser absorption spectroscopy and quantum cascade laser absorption spectrometry (QCLAS). These technologies offer clear advantages over the indirect chemiluminescence method. We tested the above mentioned direct measurement techniques for NO2 over extended time periods at atmospheric measurement stations and report on our experience including comparisons with co-located chemiluminescence instruments equipped with molybdenum as well as photolytic NO2 converters. A still open issue related to the direct measurement of NO2 is instrument calibration. Accurate and traceable reference standards and NO2 calibration gases are needed. We present results from the application of different calibration strategies based on the use of static NO2 calibration gases as well as dynamic NO2 calibration gases produced by permeation and by gas-phase titration (GPT).

  20. Enhanced chemiluminescent detection scheme for trace vapor sensing in pneumatically-tuned hollow core photonic bandgap fibers.

    PubMed

    Stolyarov, Alexander M; Gumennik, Alexander; McDaniel, William; Shapira, Ofer; Schell, Brent; Sorin, Fabien; Kuriki, Ken; Benoit, Gilles; Rose, Aimee; Joannopoulos, John D; Fink, Yoel

    2012-05-21

    We demonstrate an in-fiber gas phase chemical detection architecture in which a chemiluminescent (CL) reaction is spatially and spectrally matched to the core modes of hollow photonic bandgap (PBG) fibers in order to enhance detection efficiency. A peroxide-sensitive CL material is annularly shaped and centered within the fiber's hollow core, thereby increasing the overlap between the emission intensity and the intensity distribution of the low-loss fiber modes. This configuration improves the sensitivity by 0.9 dB/cm compared to coating the material directly on the inner fiber surface, where coupling to both higher loss core modes and cladding modes is enhanced. By integrating the former configuration with a custom-built optofluidic system designed for concomitant controlled vapor delivery and emission measurement, we achieve a limit-of-detection of 100 parts per billion (ppb) for hydrogen peroxide vapor. The PBG fibers are produced by a new fabrication method whereby external gas pressure is used as a control knob to actively tune the transmission bandgaps through the entire visible range during the thermal drawing process.

  1. Determination of volatile nitrosamines in grilled lamb and vegetables using comprehensive gas chromatography - nitrogen chemiluminescence detection.

    PubMed

    Kocak, D; Ozel, M Z; Gogus, F; Hamilton, J F; Lewis, A C

    2012-12-15

    The grilling of meat may generate dangerous levels of mutagenic and carcinogenic nitrosamines (NAs). Meat and vegetable samples underwent a two-step solid-phase extraction before analysis by comprehensive gas chromatography with a nitrogen chemiluminescence detection system (GCxGC-NCD). The GCxGC-NCD method showed high selectivity, sensitivity and equimolarity in its response to six specific NAs. NA contamination of charcoal-grilled lamb at various stages of cooking and with various fat contents and also charcoal-grilled vegetables were investigated. The grilling of lamb on unready charcoal resulted in the formation of considerable quantities of NAs. Grilling lamb on properly prepared, ready charcoal resulted in an increase in total concentrations of six NAs from 0 to 4.51 μg kg(-1) over a period of 16 min. Increasing the fat content of the grilled lamb from 5% to 20% caused a modest increase in total concentrations of the six investigated NAs from 4.51 to 5.30 μg kg(-1). Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Chemiluminescence studies between aqueous phase synthesized mercaptosuccinic acid capped cadmium telluride quantum dots and luminol-H2O2

    NASA Astrophysics Data System (ADS)

    Kaviyarasan, Kulandaivelu; Anandan, Sambandam; Mangalaraja, Ramalinga Viswanathan; Asiri, Abdullah M.; Wu, Jerry J.

    2016-08-01

    Mercaptosuccinic acid capped Cadmium telluride quantum dots have been successfully synthesized via aqueous phase method. The products were well characterized by a number of analytical techniques, including FT-IR, XRD, HRTEM, and a corrected particle size analysis by the statistical treatment of several AFM measurements. Chemiluminescence experiments were performed to explore the resonance energy transfer between chemiluminescence donor (luminol-H2O2 system) and acceptor CdTe QDs. The combination of such donor and acceptor dramatically reduce the fluorescence while compared to pristine CdTe QDs without any exciting light source, which is due to the occurrence of chemiluminescence resonance energy transfer (CRET) processes.

  3. Effect of reactor loading on atomic oxygen concentration as measured by NO chemiluminescence

    NASA Technical Reports Server (NTRS)

    Lerner, N. R.

    1989-01-01

    It has previously been observed that the etch rate of polyethylene samples in the afterglow of an RF discharge in oxygen increases with reactor loading. This enhancement of the etch rate is attributed to reactive gas phase products of the polymer etching. In the present work, emission spectroscopy is employed to examine the species present in the gas phase during etching of polyethylene. In particular, the concentration of atomic oxygen downstream from the polyethylene samples is studied as a function of the reactor loading. It is found that the concentration of atomic oxygen increases as the reactor loading is increased. The increase of etch rate with increased reactor loading is attributed to the increase of atomic oxygen concentration in the vicinity of the sample.

  4. A low Earth orbit molecular beam space simulation facility

    NASA Technical Reports Server (NTRS)

    Cross, J. B.

    1984-01-01

    A brief synopsis of the low Earth orbit (LEO) satellite environment is presented including neutral and ionic species. Two ground based atomic and molecular beam instruments are described which are capable of simulating the interaction of spacecraft surfaces with the LEO environment and detecting the results of these interactions. The first detects mass spectrometrically low level fluxes of reactively and nonreactively surface scattered species as a function of scattering angle and velocity while the second ultrahigh velocity (UHV) molecular beam, laser induced fluorescence apparatus is capable of measuring chemiluminescence produced by either gas phase or gas-surface interactions. A number of proposed experiments are described.

  5. Optical Measurement and Visualization in High-Pressure, High-Temperature, Aviation Gas Turbine Combustors

    NASA Technical Reports Server (NTRS)

    Hicks, Yolanda R.; Anderson, Robert C.; Locke, Randy J.

    2000-01-01

    Planar laser-induced fluorescence (PLIF), planar Mie scattering (PMie), and linear (1-D) spontaneous Raman scattering are applied to flame tube and sector combustors that burn Jet-A fuel at a range of inlet temperatures and pressures that simulate conditions expected in future high-performance civilian gas turbine engines. Chemiluminescence arising from C2 in the flame was also imaged. Flame spectral emissions measurements were obtained using a scanning spectrometer. Several different advanced concept fuel injectors were examined. First-ever PLIF and chemiluminescence data are presented from the 60-atm Gas turbine combustor facility.

  6. Compilation of Atomic and Molecular Data Relevant to Gas Lasers. Volume VII.

    DTIC Science & Technology

    1980-12-01

    Schaefer and A. E. Orel, "Potential Energy Curves for Diatomic Zinc and Codmium", J. Chem. Phys. 71, 1122 (1979). 19. M. F. Golde and A. Kuaran...34Chemiluminescence of Argon Bromide. I. The Emission Spectrum of ArBr", J. Chem. Phys. 72, 434 (1980). 20. M. F. Golde and K. Kuaran, "Chemiluminescence of...72, 2469 (1980). (A-4.6 - A-4.17). 3. M. F. Golde and A. Kvaran, "Chemiluminescence of Argon Bromide. I. The Emission Spectrum of Ar Br", J. Chem

  7. Quantitative analysis of nitrogen containing compounds in microalgae based bio-oils using comprehensive two-dimensional gas-chromatography coupled to nitrogen chemiluminescence detector and time of flight mass spectrometer.

    PubMed

    Toraman, Hilal E; Franz, Kristina; Ronsse, Frederik; Van Geem, Kevin M; Marin, Guy B

    2016-08-19

    Insight in the composition of the algae derived bio-oils is crucial for the development of efficient conversion processes and better upgrading strategies for microalgae. Comprehensive two-dimensional gas chromatography (GC×GC) coupled to nitrogen chemiluminescence detector (NCD) and time-of-flight mass spectrometer (TOF-MS) allows to obtain the detailed quantitative composition of the nitrogen containing compounds in the aqueous and the organic fraction of fast pyrolysis bio-oils from microalgae. Normal phase (apolar×mid-polar) and reverse phase column (polar×apolar) combination are investigated to optimize the separation of the detected nitrogen containing compounds. The reverse phase column combination gives the most detailed information in terms of the nitrogen containing compounds. The combined information from the GC×GC-TOF-MS (qualitative) and GC×GC-NCD (quantitative) with the use of a well-chosen internal standard, i.e. caprolactam, enables the identification and quantification of nitrogen containing compounds belonging to 13 different classes: amines, imidazoles, amides, imides, nitriles, pyrazines, pyridines, indoles, pyrazoles, pyrimidines, quinolines, pyrimidinediones and other nitrogen containing compounds which were not assigned to a specific class. The aqueous fraction mostly consists of amines (4.0wt%) and imidazoles (2.8wt%) corresponding to approximately 80wt% of the total identified nitrogen containing compounds. On the other hand, the organic fraction shows a more diverse distribution of nitrogen containing compounds with the majority of the compounds quantified as amides (3.0wt%), indoles (2.0wt%), amines (1.7wt%) and imides (1.3wt%) corresponding to approximately 65wt% of the total identified nitrogen containing compounds. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. High-speed fuel tracer fluorescence and OH radical chemiluminescence imaging in a spark-ignition direct-injection engine

    NASA Astrophysics Data System (ADS)

    Smith, James D.; Sick, Volker

    2005-11-01

    An innovative technique has been demonstrated to achieve crank-angle-resolved planar laser-induced fluorescence (PLIF) of fuel followed by OH* chemiluminescence imaging in a firing direct-injected spark-ignition engine. This study used two standard KrF excimer lasers to excite toluene for tracking fuel distribution. The intensified camera system was operated at single crank-angle resolution at 2000 revolutions per minute (RPM) for 500 consecutive cycles. Through this work, it has been demonstrated that toluene and OH* can be imaged through the same optical setup while similar signal levels are obtained from both species, even at these high rates. The technique is useful for studying correlations between fuel distribution and subsequent ignition and flame propagation without the limitations of phase-averaging imaging approaches. This technique is illustrated for the effect of exhaust gas recirculation on combustion and will be useful for studies of misfire causes. Finally, a few general observations are presented as to the effect of preignition fuel distribution on subsequent combustion.

  9. Experimental and theoretical study of the gas phase reaction of ethynyl radical with methane (HCC+CH 4)

    NASA Astrophysics Data System (ADS)

    Ceursters, Benny; Thi Nguyen, Hue Minh; Peeters, Jozef; Tho Nguyen, Minh

    2000-10-01

    Absolute rate coefficients of the reaction of ethynyl radical with methane were measured for the first time at higher temperatures by a pulsed laser photolysis/chemiluminescence (PLP/CL) technique. Ethynyl radicals (HCC) radicals were generated pulsewise upon excimer laser photodissociation of acetylene at 193 nm and pseudo-first-order exponential decays of thermalized HCC were monitored in real-time by the CH( A2Δ → X2Π ) chemiluminescence produced by their reaction with O 2. The rate coefficients k(HCC+CH 4), over 295⩽T ( K)<800 , exhibit strong non-Arrhenius behaviour, being k(T)=1.39×10 -18T 2.34±0.40exp[(380±180) K/T] cm3 molecule-1 s-1. Calculations at the CCSD(T)/aug-cc-pvTZ level reveal that the direct H-abstraction yielding HCCH+CH 3 has the lowest energy barrier of about 10 kJ mol -1.

  10. High-speed fuel tracer fluorescence and OH radical chemiluminescence imaging in a spark-ignition direct-injection engine.

    PubMed

    Smith, James D; Sick, Volker

    2005-11-01

    An innovative technique has been demonstrated to achieve crank-angle-resolved planar laser-induced fluorescence (PLIF) of fuel followed by OH* chemiluminescence imaging in a firing direct-injected spark-ignition engine. This study used two standard KrF excimer lasers to excite toluene for tracking fuel distribution. The intensified camera system was operated at single crank-angle resolution at 2000 revolutions per minute (RPM) for 500 consecutive cycles. Through this work, it has been demonstrated that toluene and OH* can be imaged through the same optical setup while similar signal levels are obtained from both species, even at these high rates. The technique is useful for studying correlations between fuel distribution and subsequent ignition and flame propagation without the limitations of phase-averaging imaging approaches. This technique is illustrated for the effect of exhaust gas recirculation on combustion and will be useful for studies of misfire causes. Finally, a few general observations are presented as to the effect of preignition fuel distribution on subsequent combustion.

  11. Spectroscopic and chemical-kinetic analysis of the phases of HCCI autoignition and combustion for single- and two-stage ignition fuels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hwang, Wontae; Dec, John; Sjoeberg, Magnus

    The temporal phases of autoignition and combustion in an HCCI engine have been investigated in both an all-metal engine and a matching optical engine. Gasoline, a primary reference fuel mixture (PRF80), and several representative real-fuel constituents were examined. Only PRF80, which is a two-stage ignition fuel, exhibited a ''cool-flame'' low-temperature heat-release (LTHR) phase. For all fuels, slow exothermic reactions occurring at intermediate temperatures raised the charge temperature to the hot-ignition point. In addition to the amount of LTHR, differences in this intermediate-temperature heat-release (ITHR) phase affect the fuel ignition quality. Chemiluminescence images of iso-octane show a weak and uniform lightmore » emission during this phase. This is followed by the main high-temperature heat-release (HTHR) phase. Finally, a ''burnout'' phase was observed, with very weak uniform emission and near-zero heat-release rate (HRR). To better understand these combustion phases, chemiluminescence spectroscopy and chemical-kinetic analysis were applied for the single-stage ignition fuel, iso-octane, and the two-stage fuel, PRF80. For both fuels, the spectrum obtained during the ITHR phase was dominated by formaldehyde chemiluminescence. This was similar to the LTHR spectrum of PRF80, but the emission intensity and the temperature were much higher, indicating differences between the ITHR and LTHR phases. Chemical-kinetic modeling clarified the differences and similarities between the LTHR and ITHR phases and the cause of the enhanced ITHR with PRF80. The HTHR spectra for both fuels were dominated by a broad CO continuum with some contribution from bands of HCO, CH, and OH. The modeling showed that the CO+ O{yields}CO{sub 2}+h{nu} reaction responsible for the CO continuum emission tracks the HTHR well, explaining the strong correlation observed experimentally between the total chemiluminescence and HRR during the HTHR phase. It also showed that the CO continuum does not contribute to the ITHR and LTHR chemiluminescence. Bands of H{sub 2}O and O{sub 2} in the red and IR regions were also detected during the HTHR, which the data indicated were most likely due to thermal excitation. The very weak light emission in the ''burnout'' phase also appeared to be thermal emission from H{sub 2}O and O{sub 2}. (author)« less

  12. Emissions Control in Swirl Stabilized Spray Combusters, an Experimental and Computational Study

    DTIC Science & Technology

    2007-02-01

    dynamics and thus provide an attractive alternative for application in aircraft gas turbine engines. Triple Annular Research Swirler, which has been...octagonal combustor because it provided optical access for flame imaging while avoiding difficulty of drilling thermocouple access holes on the...indicated by the temperature distribution. c. OH* chemiluminescence image It is commonly accepted that CH* and OH* chemiluminescence represents reaction or

  13. Determination of oleamide and erucamide in polyethylene films by pressurised fluid extraction and gas chromatography.

    PubMed

    Garrido-López, Alvaro; Esquiu, Vanesa; Tena, María Teresa

    2006-08-18

    A pressurized fluid extraction (PFE) and gas chromatography-flame ionization detection (GC-FID) method is proposed to determine the slip agents in polyethylene (PE) films. The study of PFE variables was performed using a fractional factorial design (FFD) for screening and a central composite design (CCD) for optimizing the main variables obtained from the Pareto charts. The variables that were studied include temperature, static time, percentage of cyclohexane and the number of extraction cycles. The final condition selected was pure isopropanol (two times) at 105 degrees C for 16min. The recovery of spiked oleamide and erucamide was around 100%. The repeatability of the method was between 9.6% for oleamide and 8% for erucamide, expressed as relative standard deviation. Finally, the method was applied to determine oleamide and erucamide in several polyethylene films and the results were statistically equal to those obtained by pyrolysis and gas-phase chemiluminescence (CL).

  14. A Chemiluminescence Detector for Ozone Measurement.

    ERIC Educational Resources Information Center

    Carroll, H.; And Others

    An ozone detector was built and evaluated for its applicability in smog chamber studies. The detection method is based on reaction of ozone with ethylene and measurement of resultant chemiluminescence. In the first phase of evaluation, the detector's response to ozone was studied as a function of several instrument parameters, and optimum…

  15. Chemiluminescence Study on Thermal Degradation of Aircraft Tire Elastomers

    NASA Technical Reports Server (NTRS)

    Mendenhall, G. D.; Stanford, T. B.; Nathan, R. A.

    1976-01-01

    Since the autoxidative process accounts in part for the degradation of rubber, including aircraft tires, it was felt that a study of the chemiluminescence from unsaturated elastomers could contribute significantly to an understanding of the degradation mechanism. The study revealed similarities in chemiluminescence behavior between four elastomers which were investigated, and it shows that similar oxidation mechanisms occur. Oxidative chemiluminescence was observed from purified samples of cis-1,4-polybutadiene, cis-1,4-polyisoprene, trans-polypentenamer, and 1,2-polybutadiene in an oxygen atmosphere at 25-150 C. The elastomer samples were placed in a 600 watt oven which is equipped with gas inlets for introducing any desired atmosphere. Chemiluminescence emission from the samples was focused with a two inch quartz lens onto the detector of a 12" photomultiplier which is connected to a photon counter. A strip-chart recorder, connected to the counter, permitted automatic data collection. Diagrams of the apparatus are included. The chemical reactions which occurred from the thermal decomposition of the polymer samples are described, and results (and tabulated data) are discussed.

  16. Study of catalytic reaction processes on the {gamma}-Al{sub 2}O{sub 3} chemiluminescence-based gas sensors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Utsunomiya, K.; Nakagawa, M.; Nishiyama, K.

    The authors have investigated a new chemiluminescence (CL)-based gas sensor made of aluminum oxide ({gamma}-Al{sub 2}O{sub 3}) which emits CL during the catalytic oxidation of combustible vapors in air. The CL intensity is proportional to the concentration in the wide region from 1 to 1000 ppm of ethanol, butanol and acetone in air. However, it has a tendency to saturate in concentrations above 1000 ppm. For the detection of vapors in the environmental atmosphere, improvements of the sensitivity and the linear characteristics of the sensor are necessary. Catalytic reaction processes on the sensor were studied for this purpose.

  17. On-chip sample pretreatment using a porous polymer monolithic column for solid-phase microextraction and chemiluminescence determination of catechins in green tea.

    PubMed

    Lin, Ling; Chen, Hui; Wei, Huibin; Wang, Feng; Lin, Jin-Ming

    2011-10-21

    A porous polymer monolithic column for solid-phase microextraction and chemiluminescence detection was integrated into a simple microfluidic chip for the extraction and determination of catechins in green tea. The porous polymer was prepared by poly(glycidyl methacrylate-co-ethylene dimethacrylate) and modified with ethylenediamine. Catechins can be concentrated in the porous polymer monolithic column and react with potassium permanganate to give chemiluminescence. The microfluidic chip is reusable with high sensitivity and very low reagent consumption. The on-line preconcentration and detection can be realized without an elution step. The enrichment factor was calculated to be about 20 for catechins. The relative chemiluminescence intensity increased linearly with concentration of catechin from 5.0 × 10(-9) to 1.0 × 10(-6) M and the limit of detection was 1.0 × 10(-9) M. The proposed method was applied to determine catechin in green tea. The recoveries are from 90% to 110% which benefits the actual application for green tea samples.

  18. Reagentless chemiluminescence-based fiber optic sensors for regenerative life support in space

    NASA Astrophysics Data System (ADS)

    Atwater, James E.; Akse, James R.; DeHart, Jeffrey; Wheeler, Richard R., Jr.

    1995-04-01

    The initial feasibility demonstration of a reagentless chemiluminescence based fiber optic sensor technology for use in advanced regenerative life support applications in space and planetary outposts is described. The primary constraints for extraterrestrial deployment of any technology are compatibility with microgravity and hypogravity environments; minimal size, weight, and power consumption; and minimal use of expendables due to the great expense and difficulty inherent to resupply logistics. In the current research, we report the integration of solid state flow through modules for the production of aqueous phase reagents into an integrated system for the detection of important analytes by chemiluminescence, with fiber optic light transmission. By minimizing the need for resupply expendables, the use of solid phase modules makes complex chemical detection schemes practical. For the proof of concept, hydrogen peroxide and glucose were chosen as analytes. The reaction is catalyzed by glucose oxidase, an immobilized enzyme. The aqueous phase chemistry required for sensor operation is implemented using solid phase modules which adjust the pH of the influent stream, catalyze the oxidation of analyte, and provide the controlled addition of the luminophore to the flowing aqueous stream. Precise control of the pH has proven essential for the long-term sustained release of the luminophore. Electrocatalysis is achieved using a controlled potential across gold mesh and gold foil electrodes which undergo periodic polarity reversals. The development and initial characterization of performance of the reagentless fiber optic chemiluminescence sensors are presented in this paper.

  19. Determination of NH(3) gas by combination of nanosized LaCoO(3) converter with chemiluminescence detector.

    PubMed

    Shi, Jinjun; Yan, Ruoxue; Zhu, Yongfa; Zhang, Xinrong

    2003-10-17

    Combination of a novel NH(3) converter based on nanosized materials with chemiluminescence (CL) detector for the determination of NH(3) gas was demonstrated in this paper. NH(3) gas is oxidized on different nanosized catalysts to produce NO(x), which can react with luminol to generate CL emission. Eight nanosized materials were investigated as catalyst, and CL was detected from seven of them. The nanosized LaCoO(3) was chosen as the catalyst for preparing the converter because of its higher activity than others. Under the optimized conditions, the linear range of CL intensity versus concentration of NH(3) gas is 0.04-10 ppm (r=0.9951, n=14) with the detection limit of 0.014 ppm. The method offers advantages of long lifetime of the converter, fast response and high selectivity to NH(3). There was no response while the foreign substances, such as hydrogen, oxygen, nitrogen, formaldehyde, acetone and gasoline passing through the CL detection system, and the interference of CCl(4), ethanol, ethylene and toluene was insignificant.

  20. Air Pollution Instrumentation: A Trend toward Physical Methods

    ERIC Educational Resources Information Center

    Maugh, Thomas H., II

    1972-01-01

    Reviews reasons for the trend from wet chemical'' analytic techniques for measuring air pollutants toward physical methods based upon chemiluminescence, electrochemical transduction, flame ionization coupled with gas chromotography, and spectroscopy. (AL)

  1. Observation of chemiluminescence induced by hydrodynamic cavitation in microchannels.

    PubMed

    Podbevsek, D; Colombet, D; Ledoux, G; Ayela, F

    2018-05-01

    We have performed hydrodynamic cavitation experiments with an aqueous luminol solution as the working fluid. Light emission, together with the high frequency noise which characterizes cavitation, was emitted by the two-phase flow, whereas no light emission from luminol was recorded in the single phase liquid flow. Light emission occurs downstream transparent microdiaphragms. The maximum level of the recorded signal was around 180 photons per second with flow rates of 380 µl/s, that corresponds to a real order of magnitude of the chemiluminescence of 75,000 photons per second. The yield of emitted photons increases linearly with the pressure drop, which is proportional to the square of the total flow rate. Chemiluminescence of luminol is a direct and a quantitative demonstration of the presence of OH hydroxyl radicals created by hydrodynamic cavitation. The presented method could be a key to optimize channel geometry for processes where radical production is essential. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Determination of thiram in natural waters using flow-injection with cerium(IV)-quinine chemiluminescence system.

    PubMed

    Waseem, Amir; Yaqoob, Mohammad; Nabi, Abdul

    2010-01-01

    A simple and rapid flow-injection chemiluminescence method has been developed for the determination of dithiocarbamate fungicide thiram based on the chemiluminescence reaction of thiram with ceric sulfate and quinine in aqueous sulfuric acid. The present method allowed the determination of thiram in the concentration range of 7.5-2500 ng/mL and the detection limit (signal-to-noise ratio = 3) was 7.5 ng/mL with sample throughput of 120/h. The relative standard deviation was 2.5% for 10 replicate analyses of 500 ng/mL thiram. The effects of foreign species including various anions and cations present in water at environmentally relevant concentrations and some pesticides were also investigated. The proposed method was applied to determine thiram in spiked natural waters using octadecyl bonded phase silica (C(18)) cartridges for solid-phase extraction. The recoveries were in the range 99 +/- 1 to 104 +/- 1%. Copyright (c) 2009 John Wiley & Sons, Ltd.

  3. Dynamic Demos.

    ERIC Educational Resources Information Center

    Sae, Andy S. W.

    1991-01-01

    Discusses 27 chemical demonstrations involving inexpensive, readily available materials that illustrate the following concepts: acid/base properties, gas properties, characteristics of carbon dioxide, chemiluminescence, freezing point depression, heat of vaporization; density, polymers, surface tension, polarity/nonpolarity, UV absorption,…

  4. The Investigation and Semi-Empirical Modeling of Thermoacoustic Phase Relationships in a Lean Premixed Prevapourized Combustor at Elevated Pressure

    NASA Astrophysics Data System (ADS)

    Cirtwill, Joseph Daniel Maxim

    This document presents an investigation of the self-excited coupling mechanisms that occur to produce both low-amplitude intermittent, as well as high-amplitude limit-cycle pressure oscillations in an aeronautical gas turbine combustor. Measurements of a lean premixed prevapourized combustor at elevated pressure were conducted using OH* chemiluminescence, pressure transducers, stereoscopic particle image velocimetry and droplet laser scattering. Analysis of the spectra and phase relationships between the measured variables is performed to determine and describe the coupling mechanisms. A semi-empirical model is presented to explain differences in the limit-cycle pressure amplitudes observed under nominally identical operating conditions. Evidence suggests that an oscillating flux of fuel into the combustor is responsible for both intermittent and limit-cycle oscillations, though different coupling relationships are observed in each case. The final amplitude of limit-cycle oscillations is shown to be correlated with changes in the phase difference between the fuel oscillations and the pressure.

  5. Experimental analysis of thermo-acoustic instabilities in a generic gas turbine combustor by phase-correlated PIV, chemiluminescence, and laser Raman scattering measurements

    NASA Astrophysics Data System (ADS)

    Arndt, Christoph M.; Severin, Michael; Dem, Claudiu; Stöhr, Michael; Steinberg, Adam M.; Meier, Wolfgang

    2015-04-01

    A gas turbine model combustor for partially premixed swirl flames was equipped with an optical combustion chamber and operated with CH4 and air at atmospheric pressure. The burner consisted of two concentric nozzles for separately controlled air flows and a ring of holes 12 mm upstream of the nozzle exits for fuel injection. The flame described here had a thermal power of 25 kW, a global equivalence ratio of 0.7, and exhibited thermo-acoustic instabilities at a frequency of approximately 400 Hz. The phase-dependent variations in the flame shape and relative heat release rate were determined by OH* chemiluminescence imaging; the flow velocities by stereoscopic particle image velocimetry (PIV); and the major species concentrations, mixture fraction, and temperature by laser Raman scattering. The PIV measurements showed that the flow field performed a "pumping" mode with varying inflow velocities and extent of the inner recirculation zone, triggered by the pressure variations in the combustion chamber. The flow field oscillations were accompanied by variations in the mixture fraction in the inflow region and at the flame root, which in turn were mainly caused by the variations in the CH4 concentration. The mean phase-dependent changes in the fluxes of CH4 and N2 through cross-sectional planes of the combustion chamber at different heights above the nozzle were estimated by combining the PIV and Raman data. The results revealed a periodic variation in the CH4 flux by more than 150 % in relation to the mean value, due to the combined influence of the oscillating flow velocity, density variations, and CH4 concentration. Based on the experimental results, the feedback mechanism of the thermo-acoustic pulsations could be identified as a periodic fluctuation of the equivalence ratio and fuel mass flow together with a convective delay for the transport of fuel from the fuel injector to the flame zone. The combustor and the measured data are well suited for the validation of numerical combustion simulations.

  6. High-performance liquid chromatography with peroxyoxalate chemiluminescence detection of bisphenol A migrated from polycarbonate baby bottles using 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a label.

    PubMed

    Sun, Y; Wada, M; Al-Dirbashi, O; Kuroda, N; Nakazawa, H; Nakashima, K

    2000-11-10

    A highly sensitive and selective high-performance liquid chromatographic method with peroxyoxalate chemiluminescence detection for the determination of bisphenol A at sub-ppb levels is described. Bisphenol A was derivatized with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride and the excess unreacted reagent was removed by a simple solid-phase extraction procedure with recoveries of approximately 60%. The separation was carried out isocratically on an ODS column and the derivatized bisphenol A was detected by peroxyoxalate chemiluminescence. A mixture of bis[2-(3,6,9-trioxadecanyloxycarbonyl)-4-nitrophenyl]oxalate (0.6 mM) and hydrogen peroxide (25.0 mM) dissolved in acetonitrile was used as a chemiluminescence reagent solution with a mixture of imidazole-HNO3 buffer (40.0 mM, pH 7.0): acetonitrile (17:83, v/v) as a mobile phase. The linear standard curve was obtained over the range from 0.57 (2.5) to 22.8 (100) ppb (nM) (r=0.996) with a detection limit of 0.38 ppb (2.8 fmol on column) at a signal-to-noise ratio of 3. The method was successfully applied to the determination of bisphenol A in hot water in contact with commercially available baby bottle samples.

  7. Interference of oxygen, carbon dioxide, and water vapor on the analysis for oxides of nitrogen by chemiluminescence

    NASA Technical Reports Server (NTRS)

    Maahs, H. G.

    1975-01-01

    The interference of small concentrations (less than 4 percent by volume) of oxygen, carbon dioxide, and water vapor on the analysis for oxides of nitrogen by chemiluminescence was measured. The sample gas consisted primarily of nitrogen, with less than 100 parts per million concentration of nitric oxide, and with small concentrations of oxygen, carbon dioxide, and water vapor added. Results obtained under these conditions indicate that although oxygen does not measurably affect the analysis for nitric oxide, the presence of carbon dioxide and water vapor causes the indicated nitric oxide concentration to be too low. An interference factor - defined as the percentage change in indicated nitric oxide concentration (relative to the true nitric oxide concentration) divided by the percent interfering gas present - was determined for carbon dioxide to be -0.60 + or - 0.04 and for water vapor to be -2.1 + or - 0.3.

  8. Improvement of the tetrachloromercurate absorption technique for measuring low atmospheric SO2 mixing ratios

    NASA Astrophysics Data System (ADS)

    Jaeschke, W.; Beltz, N.; Haunold, W.; Krischke, U.

    1997-07-01

    During the Gas-Phase Sulfur Intercomparison Experiment (GASIE) in 1994 an analytical system for measuring sulfur dioxide mixing ratios at low parts per trillion (pptv) levels was employed. It is based on the absorption of SO2 on a tetrachloromercurate(II)-impregnated filter. The subsequent analysis uses a chemiluminescence reaction by treating the resulting disulfitomercurate(II) complex with an acidic cerium sulfate solution. An improved sampling device has been introduced that increases the maximum sampling volume from 200 L to 500 L. It is also possible to determine the blank value accurately for each sample. The absorption efficiency of the sampling system is 98.7±6.4% at a nominal flow rate of 10 L/min. The calculated (3σ) detection limit is 3±1 pptv SO2. The sample solution is stable for up to 30 days, which allows the samples to be safely stored or shipped before analysis. This permits the use of a sensitive, compact, and reliable sampling system in the field with subsequent analysis under optimal conditions in the laboratory. A continuous flow chemiluminescence (CFCL) analyzer for on-line measurements is also presented. The system is based on the same chemical principles as the described filter technique.

  9. A highly sensitive and temporal visualization system for gaseous ethanol with chemiluminescence enhancer.

    PubMed

    Arakawa, Takahiro; Ando, Eri; Wang, Xin; Kumiko, Miyajima; Kudo, Hiroyuki; Saito, Hirokazu; Mitani, Tomoyo; Takahashi, Mitsuo; Mitsubayashi, Kohji

    2012-01-01

    A two-dimensional gaseous ethanol visualization system has been developed and demonstrated using a horseradish peroxidase-luminol-hydrogen peroxide system with high-purity luminol solution and a chemiluminescence (CL) enhancer. This system measures ethanol concentrations as intensities of CL via the luminol reaction. CL was emitted when the gaseous ethanol was injected onto an enzyme-immobilized membrane, which was employed as a screen for two-dimensional gas visualization. The average intensity of CL on the substrate was linearly related to the concentration of standard ethanol gas. These results were compared with the CL intensity of the CCD camera recording image in the visualization system. This system is available for gas components not only for spatial but also for temporal analysis in real time. A high-purity sodium salt HG solution (L-HG) instead of standard luminol solution and an enhancer, eosin Y (EY) solution, were adapted for improvement of CL intensity of the system. The visualization of gaseous ethanol was achieved at a detection limit of 3 ppm at optimized concentrations of L-HG solution and EY. Copyright © 2011 John Wiley & Sons, Ltd.

  10. An experimental study of the effect of a pilot flame on technically pre-mixed, self-excited combustion instabilities

    NASA Astrophysics Data System (ADS)

    O'Meara, Bridget C.

    Combustion instabilities are a problem facing the gas turbine industry in the operation of lean, pre-mixed combustors. Secondary flames known as "pilot flames" are a common passive control strategy for eliminating combustion instabilities in industrial gas turbines, but the underlying mechanisms responsible for the pilot flame's stabilizing effect are not well understood. This dissertation presents an experimental study of a pilot flame in a single-nozzle, swirl-stabilized, variable length atmospheric combustion test facility and the effect of the pilot on combustion instabilities. A variable length combustor tuned the acoustics of the system to excite instabilities over a range of operating conditions without a pilot flame. The inlet velocity was varied from 25 -- 50 m/s and the equivalence ratio was varied from 0.525 -- 0.65. This range of operating conditions was determined by the operating range of the combustion test facility. Stability at each operating condition and combustor length was characterized by measurements of pressure oscillations in the combustor. The effect of the pilot flame on the magnitude and frequency of combustor stability was then investigated. The mechanisms responsible for the pilot flame effect were studied using chemiluminescence flame images of both stable and unstable flames. Stable flame structure was investigated using stable flame images of CH* chemiluminescence emission. The effect of the pilot on stable flame metrics such as flame length, flame angle, and flame width was investigated. In addition, a new flame metric, flame base distance, was defined to characterize the effect of the pilot flame on stable flame anchoring of the flame base to the centerbody. The effect of the pilot flame on flame base anchoring was investigated because the improved stability with a pilot flame is usually attributed to improved flame anchoring through the recirculation of hot products from the pilot to the main flame base. Chemiluminescence images of unstable flames were used to identify several instability mechanisms and infer how these mechanisms are affected by the pilot flame. Flame images of cases in which the pilot flame did not eliminate the instability were investigated to understand why the pilot flame is not effective in certain cases. The phase of unstable pilot flame oscillations was investigated to determine how the phase of pilot flame oscillations may affect its ability to interfere with instability mechanisms in the main flame. A forced flame response study was conducted to determine the effect of inlet velocity oscillation amplitude on the pilot flame. The flame response was characterized by measurements of velocity oscillations in the injector and chemiluminescence intensity oscillations determined from flame images. As the forcing amplitude increases, the pilot flame's effect on the flame transfer function magnitude becomes weaker. Flame images show that as the forcing amplitude increases, the pilot flame oscillations increase, leading to an ineffective pilot. The results of the flame response portion of this study highlight the effect of instability amplitude on the ability of a pilot flame to eliminate a combustion instability.

  11. Portable instrument and method for detecting reduced sulfur compounds in a gas

    DOEpatents

    Gaffney, J.S.; Kelly, T.J.; Tanner, R.L.

    1983-06-01

    A portable real time instrument for detecting concentrations in the part per billion range of reduced sulfur compounds in a sample gas. Ozonized air or oxygen and reduced sulfur compounds in a sample gas stream react to produce chemiluminescence in a reaction chamber and the emitted light is filtered and observed by a photomultiplier to detect reduced sulfur compounds. Selective response to individual sulfur compounds is achieved by varying reaction chamber temperature and ozone and sample gas flows, and by the use of either air or oxygen as the ozone source gas.

  12. Chemiluminescent photon yields measured in the flame photometric detector on chromatographic peaks containing sulfur, phosphorus, manganese, ruthenium, iron or selenium

    NASA Astrophysics Data System (ADS)

    Aue, Walter A.; Singh, Hameraj

    2001-05-01

    Photon yields — the number of photons generated per analyte atom — are of obvious analytical and mechanistic importance in flame chemiluminescence. However, such numbers are unavailable for spectral detectors in gas chromatography (as well as for most conventional spectroscopic systems). In this study, photon yields have been determined for the chemiluminescence of several elements in the flame photometric detector (FPD). The number of photons generated per atom of FPD-active element was 2×10 -3 for sulfur (emitter S 2*, test compound thianaphthene), 3×10 -3 for phosphorus [HPO*, tris(pentafluorophenyl)phosphine], 8×10 -3 for manganese (Mn*, methylcyclopentadienyl manganese tricarbonyl), 3×10 -3 for ruthenium (emitter unknown, ruthenocene), 4×10 -5 for iron (Fe*, ferrocene) and 2×10 -4 for selenium (Se 2*, dimethylbenzselenazole). Total flows, maximum thermocouple temperatures, and visible flame volumes have also been estimated for each element under signal/noise-optimized conditions in order to provide a database for kinetic calculations.

  13. Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF

    NASA Astrophysics Data System (ADS)

    Wu, Yi; Modica, Vincent; Yu, Xilong; Li, Fei; Grisch, Frédéric

    2018-01-01

    The effects of optical diagnostic techniques on the accuracy of laminar flame speed measured from Bunsen flames were investigated. Laminar flame speed measurements were conducted for different fuel/air mixtures including CH4/air, acetone/air and kerosene (Jet A-1)/air in applying different optical diagnostic techniques, i.e. OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF. It is found that the OH* chemiluminescence imaging technique cannot directly derive the location of the outer edge of the fresh gases and it is necessary to correct the position of the OH* peak to guarantee the accuracy of the measurements. OH-PLIF and acetone/kerosene-PLIF respectively are able to measure the disappearance of the fresh gas contour and the appearance of the reaction zone. It shows that the aromatic-PLIF technique gives similar laminar flame speed values when compared with those obtained from corrected OH* chemiluminescence images. However, discrepancies were observed between the OH-PLIF and the aromatic-PLIF techniques, in that OH-PLIF slightly underestimates laminar flame speeds by up to 5%. The difference between the flame contours obtained from different optical techniques are further analysed and illustrated with 1D flame structure simulation using detailed kinetic mechanisms.

  14. [Immunologic indexes, enzyme status of lymphocytes and functional activity of blood neutrophils in children with infectious mononucleosis caused by Epstein-Barr virus].

    PubMed

    Kurtasova, L M; Tolstikova, A E; Savchenko, A A

    2013-01-01

    Explore the immunological parameters, levels of activity of NAD(P)-dependent dehydrogenases lymphocytes, interferon status parameters, phagocytic activity and chemiluminescence response of neutrophils in the blood of children in the acute phase of infectious mononucleosis caused by the Epstein-Barr virus. 65 children at the age of 4-6 years old with infectious mononucleosis caused by EBV in acute phase were observed. Such indexes as cell-mediated, humoral and interferon immunity, NAD(P)-depended dehydrogenases activity in blood lymphocyte, phagocytes activity, levels of spontaneous and induced chemiluminescence ofperipheral blood neutrophils were studied. Children with EVB-infection have immunophenotype spectrum changes and changes of enzymes status of blood lymphocytes against the increasing in leucocytes and the useful increasing in lymphocytes. The useful increasing in IgA, IgM, IgG contenting in serum blood were found. The decreasing of spontaneous production of IFN alpha and the decreasing of induced production of IFNalpha, IFNgamma were determined. The breach of phagocytes activity and chemiluminescent response of blood neutrophils were found. The children in the acute phase of infectious mononucleosis caused by the Epstein-Barr virus, there are changes in the immune status, changes the activity of NAD(P)-dependent dehydrogenases in blood lymphocytes, marked changes in functional and metabolic state of peripheral blood neutrophils.

  15. Temperature-dependent ozone chemiluminescence: A new approach for hydrocarbon monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marley, N.; Gaffney, J.

    1996-12-31

    Ozone chemiluminescent reactions have been used for some time to detect oxides of nitrogen, ozone, and olefins in air quality studies. Current procedures use non-methane hydrocarbon analyzers based on the flame ionization detector (FID), which quantitate total non-methane hydrocarbons but do not differentiate between the wide variety of volatile organic classes and oxygenates. The other methodology that has been used, gas chromatography/mass spectroscopy (GC/MS), can measure a variety of individual hydrocarbon species and classes, but it is costly, time-consuming, and labor intensive and is not amenable to real-time measurements. Presented here is preliminary research aimed at the development of anmore » alternative to FID and GC/MS: the ozone chemiluminescent detector (OCD) for measurement of a variety of hydrocarbon species and classes by use of the temperature dependence of ozone chemiluminescent reactions. Responses for various hydrocarbon classes obtained with an OCD operated at 170 C or the FID were compared. The results indicate that the OCD detector responds like a total carbon detector at this temperature, with sensitivities 10-100 times higher than those of a FID. Use of the temperature dependence of the chemiluminescent reaction and prereactors will apparently make a real-time hydrocarbon analyzer based on this approach feasible for determination of high-, moderate-, and low-reactivity hydrocarbon levels in ambient air. The OCD approach may be very useful in determining oxygenate emissions from motor vehicles, particularly alternative fuels. The OCD may also be useful in monitoring of ambient air for natural hydrocarbon emissions.« less

  16. A novel flow injection chemiluminescence method for automated and miniaturized determination of phenols in smoked food samples.

    PubMed

    Vakh, Christina; Evdokimova, Ekaterina; Pochivalov, Aleksei; Moskvin, Leonid; Bulatov, Andrey

    2017-12-15

    An easily performed fully automated and miniaturized flow injection chemiluminescence (CL) method for determination of phenols in smoked food samples has been proposed. This method includes the ultrasound assisted solid-liquid extraction coupled with gas-diffusion separation of phenols from smoked food sample and analytes absorption into a NaOH solution in a specially designed gas-diffusion cell. The flow system was designed to focus on automation and miniaturization with minimal sample and reagent consumption by inexpensive instrumentation. The luminol - N-bromosuccinimide system in an alkaline medium was used for the CL determination of phenols. The limit of detection of the proposed procedure was 3·10 -8 ·molL -1 (0.01mgkg -1 ) in terms of phenol. The presented method demonstrated to be a good tool for easy, rapid and cost-effective point-of-need screening phenols in smoked food samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Laser-based investigations in gas turbine model combustors

    NASA Astrophysics Data System (ADS)

    Meier, W.; Boxx, I.; Stöhr, M.; Carter, C. D.

    2010-10-01

    Dynamic processes in gas turbine (GT) combustors play a key role in flame stabilization and extinction, combustion instabilities and pollutant formation, and present a challenge for experimental as well as numerical investigations. These phenomena were investigated in two gas turbine model combustors for premixed and partially premixed CH4/air swirl flames at atmospheric pressure. Optical access through large quartz windows enabled the application of laser Raman scattering, planar laser-induced fluorescence (PLIF) of OH, particle image velocimetry (PIV) at repetition rates up to 10 kHz and the simultaneous application of OH PLIF and PIV at a repetition rate of 5 kHz. Effects of unmixedness and reaction progress in lean premixed GT flames were revealed and quantified by Raman scattering. In a thermo-acoustically unstable flame, the cyclic variation in mixture fraction and its role for the feedback mechanism of the instability are addressed. In a partially premixed oscillating swirl flame, the cyclic variations of the heat release and the flow field were characterized by chemiluminescence imaging and PIV, respectively. Using phase-correlated Raman scattering measurements, significant phase-dependent variations of the mixture fraction and fuel distributions were revealed. The flame structures and the shape of the reaction zones were visualized by planar imaging of OH distribution. The simultaneous OH PLIF/PIV high-speed measurements revealed the time history of the flow field-flame interaction and demonstrated the development of a local flame extinction event. Further, the influence of a precessing vortex core on the flame topology and its dynamics is discussed.

  18. The determination of psilocin and psilocybin in hallucinogenic mushrooms by HPLC utilizing a dual reagent acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection system.

    PubMed

    Anastos, Nicole; Lewis, Simon W; Barnett, Neil W; Sims, D Noel

    2006-01-01

    This paper describes a procedure for the determination of psilocin and psilocybin in mushroom extracts using high-performance liquid chromatography with postcolumn chemiluminescence detection. A number of extraction methods for psilocin and psilocybin in hallucinogenic mushrooms were investigated, with a simple methanolic extraction being found to be most effective. Psilocin and psilocybin were extracted from a variety of hallucinogenic mushrooms using methanol. The analytes were separated on a C12 column using a (95:5% v/v) methanol:10 mM ammonium formate, pH 3.5 mobile phase with a run time of 5 min. Detection was realized through a dual reagent chemiluminescence detection system of acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II). The chemiluminescence detection system gave improved detectability when compared with UV absorption at 269 nm, with detection limits of 1.2 x 10(-8) and 3.5 x 10(-9) mol/L being obtained for psilocin and psilocybin, respectively. The procedure was applied to the determination of psilocin and psilocybin in three Australian species of hallucinogenic mushroom.

  19. Highly sensitive determination of diclofenac based on resin beads and a novel polyclonal antibody by using flow injection chemiluminescence competitive immunoassay

    NASA Astrophysics Data System (ADS)

    Shi, Jing; Xu, Mingxia; Tang, Qinghui; Zhao, Kang; Deng, Anping; Li, Jianguo

    2018-02-01

    A novel flow injection chemiluminescence immunoassay for simple, sensitive and low-cost detection of diclofenac was established based on specific binding of antigen and antibody. Carboxylic resin beads used as solid phase carrier materials provided good biocompatibility and large surface-to-volume ratio for modifying more coating antigen. There was a competitive process between the diclofenac in solution and the immobilized coating antigen to react with the limited binding sites of the polyclonal antibody to form the immunocomplex. The second antibody labelled with horseradish peroxidase was introduced into the immunosensor and trapped by captured polyclonal antibody against diclofenac, which could effectively amplify chemiluminescence signals of luminol-PIP-H2O2. Under optimal conditions, the diclofenac could be detected quantitatively. The chemiluminescence intensity decreased linearly with the logarithm of the diclofenac concentration in the range of 0.1-100 ng mL- 1 with a detection limit of 0.05 ng mL- 1 at a signal-to-noise ratio of 3. The immunosensor exhibited high sensitivity, specificity and acceptable stability. This easy-operated and cost-effective analytical method could be valuable for the diclofenac determination in real water samples.

  20. Analysis of S-nitrosothiols via Copper Cysteine (2C) and Copper Cysteine - Carbon Monoxide (3C) Methods

    PubMed Central

    Rogers, Stephen C.; Gibbons, Lindsey B.; Griffin, Sherraine; Doctor, Allan

    2012-01-01

    This chapter summarizes the principles of RSNO measurement in the gas phase, utilizing ozone-based chemiluminescence and the copper cysteine (2C) ± carbon monoxide (3C) reagent. Although an indirect method for quantifying RSNOs, this assay represents one of the most robust methodologies available. It exploits the NO• detection sensitivity of ozone based chemiluminscence, which is within the range required to detect physiological concentrations of RSNO metabolites. Additionally, the specificity of the copper cysteine (2C and 3C) reagent for RSNOs negates the need for sample pretreatment, thereby minimizing the likelihood of sample contamination (false positive results), NO species inter-conversion, or the loss of certain highly labile RSNO species. Herein, we outline the principles of this methodology, summarizing key issues, potential pitfalls and corresponding solutions. PMID:23116707

  1. Quantitative determination of atmospheric hydroperoxyl radical

    DOEpatents

    Springston, Stephen R.; Lloyd, Judith; Zheng, Jun

    2007-10-23

    A method for the quantitative determination of atmospheric hydroperoxyl radical comprising: (a) contacting a liquid phase atmospheric sample with a chemiluminescent compound which luminesces on contact with hydroperoxyl radical; (b) determining luminescence intensity from the liquid phase atmospheric sample; and (c) comparing said luminescence intensity from the liquid phase atmospheric sample to a standard luminescence intensity for hydroperoxyl radical. An apparatus for automating the method is also included.

  2. Chemiluminescence analyzer of NOx as a high-throughput screening tool in selective catalytic reduction of NO

    PubMed Central

    Oh, Kwang Seok; Woo, Seong Ihl

    2011-01-01

    A chemiluminescence-based analyzer of NOx gas species has been applied for high-throughput screening of a library of catalytic materials. The applicability of the commercial NOx analyzer as a rapid screening tool was evaluated using selective catalytic reduction of NO gas. A library of 60 binary alloys composed of Pt and Co, Zr, La, Ce, Fe or W on Al2O3 substrate was tested for the efficiency of NOx removal using a home-built 64-channel parallel and sequential tubular reactor. The NOx concentrations measured by the NOx analyzer agreed well with the results obtained using micro gas chromatography for a reference catalyst consisting of 1 wt% Pt on γ-Al2O3. Most alloys showed high efficiency at 275 °C, which is typical of Pt-based catalysts for selective catalytic reduction of NO. The screening with NOx analyzer allowed to select Pt-Ce(X) (X=1–3) and Pt–Fe(2) as the optimal catalysts for NOx removal: 73% NOx conversion was achieved with the Pt–Fe(2) alloy, which was much better than the results for the reference catalyst and the other library alloys. This study demonstrates a sequential high-throughput method of practical evaluation of catalysts for the selective reduction of NO. PMID:27877438

  3. Nitrogen oxides from burning forest fuels examined by thermogravimetry and evolved gas analysis

    Treesearch

    H.B. Clements; Charles K. McMahon

    1980-01-01

    Abstract. Twelve forest fuels that varied widely in nitrogen content were burned in a thermogravimetric system, and nitrogen oxide production was analyzed by chemiluminescence. The effects of fuel nitrogen concentration, available oxygen, flow rate, and heating rate on nitrogen oxide production were examined.Results show that fuel nitrogen is an...

  4. Singlet Oxygen at the Laundromat

    NASA Astrophysics Data System (ADS)

    Keeports, David

    1995-09-01

    Singlet molecular oxygen is an interesting molecule both visually and theoretically, since its red chemiluminescence can be analyzed by the application of simple molecular orbital theory. It can be produced from the reaction of hydrogen peroxide from either chlorine gas or hypochlorite ion from household bleach. Here we demostrate how to produce it using simple laundry cleansers.

  5. Methodology for the investigation of ignition near hot surfaces in a high-pressure shock tube

    NASA Astrophysics Data System (ADS)

    Niegemann, P.; Fikri, M.; Wlokas, I.; Röder, M.; Schulz, C.

    2018-05-01

    Autoignition of fuel/air mixtures is a determining process in internal combustion engines. Ignition can start either homogeneously in the gas phase after compression or in the vicinity of hot surfaces. While ignition properties of commercial fuels are conventionally described by a single quantity (octane number), it is known that some fuels have a varying propensity to the two processes. We present a new experimental concept that generates well-controlled temperature inhomogeneities in the shock-heated gases of a high-pressure shock tube. A shock-heated reactive mixture is brought into contact with a heated silicon nitride ceramic glow plug. The glow-plug temperature can be set up to 1200 K, higher than the post-reflected-shock gas temperatures (650-1050 K). High-repetition-rate chemiluminescence imaging is used to localize the onset of ignition in the vicinity of the hot surface. In experiments with ethanol, the results show that in most cases under shock-heated conditions, the ignition begins inhomogeneously in the vicinity of the glow plug and is favored because of the high wall temperature. Additionally, the interaction of geometry, external heating, and gas-dynamic effects was investigated by numerical simulations of the shock wave in a non-reactive flow.

  6. Methodology for the investigation of ignition near hot surfaces in a high-pressure shock tube.

    PubMed

    Niegemann, P; Fikri, M; Wlokas, I; Röder, M; Schulz, C

    2018-05-01

    Autoignition of fuel/air mixtures is a determining process in internal combustion engines. Ignition can start either homogeneously in the gas phase after compression or in the vicinity of hot surfaces. While ignition properties of commercial fuels are conventionally described by a single quantity (octane number), it is known that some fuels have a varying propensity to the two processes. We present a new experimental concept that generates well-controlled temperature inhomogeneities in the shock-heated gases of a high-pressure shock tube. A shock-heated reactive mixture is brought into contact with a heated silicon nitride ceramic glow plug. The glow-plug temperature can be set up to 1200 K, higher than the post-reflected-shock gas temperatures (650-1050 K). High-repetition-rate chemiluminescence imaging is used to localize the onset of ignition in the vicinity of the hot surface. In experiments with ethanol, the results show that in most cases under shock-heated conditions, the ignition begins inhomogeneously in the vicinity of the glow plug and is favored because of the high wall temperature. Additionally, the interaction of geometry, external heating, and gas-dynamic effects was investigated by numerical simulations of the shock wave in a non-reactive flow.

  7. Atmospheric H sub 2 O sub 2 field measurements in a tropical environment: Bahia, Brazil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacob, P.; Tavares, T.M.; Rocha, V.C.

    1988-09-01

    Concentrations of H{sub 2}O{sub 2} in atmospheric gas and liquid phases were determined for the first time in the South Hemisphere. Measurements were taken in the Salvador area, Bahia, 13{degree}S, 38.3{degree}W, both at the seaside and 500m away from it, as well as at 270km inland, during March-April 1988. Gaseous samples were taken by cryogenic technique and rain by wet only collection. Analyses were performed by the peroxyoxalate chemiluminescence method. This methodology is the same used at Dortmund University and intercalibration was carried out allowing for unrestricted comparisons between previous results from Germany with present ones. Field measurements showed themore » following: a- H{sub 2}O{sub 2} absolute concentrations in the gas phase ranged from 200 ppt to 3.9 ppb, which is roughly five times that of Dortmund. b-Diurnal variation show maximum concentrations in early afternoon, somewhat earlier than the corresponding ones for Germany. Decreasing concentration during night in Bahia are most probably connected with condensation processes, for an increase in relative humidity reaching 100% is found in most cases at this time. c- H{sub 2}O{sub 2} in rain during daytime varied between 600-6770 ppbw, averaging 2337 ppbw, which is five times greater than daytime summer rain in Dortmund.« less

  8. Infrared emission from desorbed NO2(*) and NO(*)

    NASA Technical Reports Server (NTRS)

    Kofsky, I. L.; Barrett, J. L.

    1985-01-01

    Infrared photons from the radiative cascade accompany both the gas phase NO2 continuum chemiluminescence (which originates from its 2B2 and 2B1 states) and the NO beta bands. When these upper electronic states are excited by recombination/desorption at surfaces of low Earth orbiting spacecraft, similar IR emission spectrums will be observed. The principal NO2 features (other than the long wavelength tail of its electronic transitions) are the nu sub 3 fundamental sequence near 6.2 microns and nu sub 1 + nu sub 3 intercombination bands near 3.6 microns; NO would emit the delta v=1 and delta v=2 systems above 5.3 and 2.7 microns. Because of the long radiative lifetimes of the upper vibrational states, the infrared radiances in projections parallel to the vehicle surface (which we estimate) are substantially less than those of the visible and ultraviolet glows.

  9. Kinetics of the O plus O3 reaction. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Mccrumb, J. L.; Kaufman, F.

    1971-01-01

    The gas phase reaction O + O3 yields 2 O2 was studied directly in a flow system under conditions of excess ozone, with O-atoms produced by thermal decomposition of Ar-O3 mixtures on a Nernst Glower, and measurement of the spatial O-atom decay by O + NO chemiluminescence with small, variable NO additions. The rate constant was found to be (9.6 + or - 0.7) x 10 to the minus 15th power cu/cm/molecule/sec at 298 K. Over the temperature range 269 to 409 K a rate expression (1.78 + or - 0.28) x 10 to the 11th power exp((-4.46 + or - 0.10 kcal/mole)/RT) is reported. The effects of interference by O2 (delta sub g) and product excitation are discussed, and the present results are compared with earlier investigations.

  10. Advanced Reciprocating Engine Systems (ARES) Research at Argonne National Laboratory. A Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Sreenath; Biruduganti, Muni; Bihari, Bipin

    The goals of these experiments were to determine the potential of employing spectral measurements to deduce combustion metrics such as HRR, combustion temperatures, and equivalence ratios in a natural gas-fired reciprocating engine. A laser-ignited, natural gas-fired single-cylinder research engine was operated at various equivalence ratios between 0.6 and 1.0, while varying the EGR levels between 0% and maximum to thereby ensure steady combustion. Crank angle-resolved spectral signatures were collected over 266-795 nm, encompassing chemiluminescence emissions from OH*, CH*, and predominantly by CO2* species. Further, laser-induced gas breakdown spectra were recorded under various engine operating conditions.

  11. Research on signal processing method for total organic carbon of water quality online monitor

    NASA Astrophysics Data System (ADS)

    Ma, R.; Xie, Z. X.; Chu, D. Z.; Zhang, S. W.; Cao, X.; Wu, N.

    2017-08-01

    At present, there is no rapid, stable and effective approach of total organic carbon (TOC) measurement in the Marine environmental online monitoring field. Therefore, this paper proposes an online TOC monitor of chemiluminescence signal processing method. The weak optical signal detected by photomultiplier tube can be enhanced and converted by a series of signal processing module: phase-locked amplifier module, fourth-order band pass filter module and AD conversion module. After a long time of comparison test & measurement, compared with the traditional method, on the premise of sufficient accuracy, this chemiluminescence signal processing method can offer greatly improved measuring speed and high practicability for online monitoring.

  12. Fiber-Optic Chemiluminescent Biosensors for Monitoring Aqueous Alcohols and Other Water Quality Parameters

    NASA Technical Reports Server (NTRS)

    Verostko, Charles E. (Inventor); Atwater, James E. (Inventor); Akse, James R. (Inventor); DeHart, Jeffrey L. (Inventor); Wheeler, Richard R. (Inventor)

    1998-01-01

    A "reagentless" chemiluminescent biosensor and method for the determination of hydrogen peroxide, ethanol and D-glucose in water is disclosed. An aqueous stream is basified by passing it through a solid phase base bed. Luminol is then dissolved in the basified effluent at a controlled rate. Oxidation of the luminol is catalyzed by the target chemical to produce emitted light. The intensity of the emitted light is detected as a measure of the target chemical concentration in the aqueous stream. The emitted light can be transmitted by a fiber optic bundle to a remote location from the aqueous stream for a remote reading of the target chemical concentration.

  13. Feasibility study for rocket ozone measurements in the 50 to 80 km region using a chemiluminescent technique

    NASA Technical Reports Server (NTRS)

    Goodman, P.

    1973-01-01

    A study has been conducted to determine the feasibility of increasing sensitivity for ozone detection. The detection technique employed is the chemiluminescent reaction of ozone with a rhodamine-B impregnated disk. Previously achieved sensitivities are required to be increased by a factor of about 20 to permit measurements at altitudes of 80 km. Sensitivity was increased by using a more sensitive photomultiplier tube, by increasing the gas velocity past the disk, by different disk preparation techniques, and by using reflective coatings in the disk chamber and on the uncoated side of the glass disk. Reflective coatings provided the largest sensitivity increase. The sum of all these changes was a sensitivity increased by an estimated factor of 70, more than sufficient to permit measurement of ambient ozone concentrations at altitudes of 80 km.

  14. 40 CFR 1065.270 - Chemiluminescent detector.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Chemiluminescent detector. 1065.270... Chemiluminescent detector. (a) Application. You may use a chemiluminescent detector (CLD) to measure NOX... chemiluminescent detector for comparison with any proposed alternate measurement procedure under § 1065.10. (b...

  15. Numerical evaluation of equivalence ratio measurement using OH{sup *} and CH{sup *} chemiluminescence in premixed and non-premixed methane-air flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panoutsos, C.S.; Hardalupas, Y.; Taylor, A.M.K.P.

    This work presents results from detailed chemical kinetics calculations of electronically excited OH (A{sup 2}{sigma}, denoted as OH{sup *}) and CH (A{sup 2}{delta}, denoted as CH{sup *}) chemiluminescent species in laminar premixed and non-premixed counterflow methane-air flames, at atmospheric pressure. Eight different detailed chemistry mechanisms, with added elementary reactions that account for the formation and destruction of the chemiluminescent species OH{sup *} and CH{sup *}, are studied. The effects of flow strain rate and equivalence ratio on the chemiluminescent intensities of OH{sup *}, CH{sup *} and their ratio are studied and the results are compared to chemiluminescent intensity ratio measurementsmore » from premixed laminar counterflow natural gas-air flames. This is done in order to numerically evaluate the measurement of equivalence ratio using OH{sup *} and CH{sup *} chemiluminescence, an experimental practise that is used in the literature. The calculations reproduced the experimental observation that there is no effect of strain rate on the chemiluminescent intensity ratio of OH{sup *} to CH{sup *}, and that the ratio is a monotonic function of equivalence ratio. In contrast, the strain rate was found to have an effect on both the OH{sup *} and CH{sup *} intensities, in agreement with experiment. The calculated OH{sup *}/CH{sup *} values showed that only five out of the eight mechanisms studied were within the same order of magnitude with the experimental data. A new mechanism, proposed in this work, gave results that agreed with experiment within 30%. It was found that the location of maximum emitted intensity from the excited species OH{sup *} and CH{sup *} was displaced by less than 65 and 115 {mu}m, respectively, away from the maximum of the heat release rate, in agreement with experiments, which is small relative to the spatial resolution of experimental methods applied to combustion applications, and, therefore, it is expected that intensity from the OH{sup *} and CH{sup *} excited radicals can be used to identify the location of the reaction zone. Calculations of the OH{sup *}/CH{sup *} intensity ratio for strained non-premixed counterflow methane-air flames showed that the intensity ratio takes different values from those for premixed flames, and therefore has the potential to be used as a criterion to distinguish between premixed and non-premixed reaction in turbulent flames. (author)« less

  16. Radical production from photosensitization of imidazoles

    NASA Astrophysics Data System (ADS)

    Corral Arroyo, P.; Gonzalez, L.; Steimer, S.; Aellig, R.; Volkamer, R. M.; George, C.; Bartels-Rausch, T.; Ammann, M.

    2015-12-01

    Reactions promoted by light are key in atmospheric chemistry. Some of them occur in the condensed phase of aerosols containing light absorbing organic compounds (George et al., 2015). This work explores the radical reactions initiated by near-UV light in mixtures of citric acid (CA) and imidazole-2-carboxaldehyde (IC) using NO as a probe molecule for HO2, by means of coated wall flow tube experiments. Citric acid may act as H atom or electron donor in condensed phase radical cycles. IC may act as a photosensitizer. The loss of NO was measured by a chemiluminescence detector. The dependence of the NO loss on the NO concentration, the IC/CA ratio in the film, relative humidity, light intensity, oxygen molar fraction were investigated as well as the HONO and NO2 yields. We also added halide salts to investigate the effect of a competing electron donor in the system and the output of halogens to the gas phase. We found a correlation between the loss of NO above the film and the molar ratio of IC/CA and the light intensity. The variation of the NO loss with oxygen corroborates a mechanism, in which the triplet excited state of IC is reduced by citric acid, to a reduced ketyl radical that transfers an electron to molecular oxygen, which in turn leads to production of HO2 radicals. Therefore, the NO loss in the gas phase is related to the production of HO2 radicals. Relative humidity had a strong impact on the HO2 output, which shows a maximum production rate at around 30%. The addition of halide ions (X- = Cl-, Br-, I-) increases the HO2 output at low concentration and decrease it at higher concentration when X2- radical ions likely scavenge HO2. We could preliminarily quantify for the first time the contribution of these processes to the oxidative capacity in the atmosphere and conclude that their role is significant for aerosol aging and potentially a significant source of halogen compounds to the gas phase.

  17. A Study of Acoustic Forcing on Gas Centered Swirl Coaxial Reacting Flows (Conference Paper with Briefing Charts)

    DTIC Science & Technology

    2017-01-09

    intensifier with a Semrock filter (FF01-425/26). The reflective surface of this dichroic mirror rejected the blue light portion from the broadband...chemiluminescence was also imaged using a HiCATT intensifier with a Semrock filter (FF01-320/40). The shadowgraph camera was set to a gate of 7 µs

  18. Selective determination of semi-volatile thiophene compounds in water by molecularly imprinted polymer thin films with direct headspace gas chromatography sulfur chemiluminescence detection.

    PubMed

    Hijazi, Hassan Y; Bottaro, Christina S

    2018-02-26

    Water-compatible molecularly imprinted polymer (MIP) thin films are coupled with headspace gas chromatography sulfur chemiluminescence detection (HS-GC-SCD) to create a new approach for the determination of trace concentrations of thiophene compounds in water samples. Thiophene compounds are persistent, typically petrogenic, organic pollutants of concern due to their potential for biomagnification and bioaccumulation, mutagenicity, and carcinogenicity in terrestrial and aquatic fauna. Identification and quantitation in water, particularly following oil spills, is a priority. Following adsorption of the thiophenes to the MIPs, the MIP-bound analytes are analyzed directly by HS-GC-SCD, with minimal sample manipulation and virtually no organic solvent. Calibration curves of spiked seawater were linear from 5 μg L -1 to 100 μg L -1 and limits of detection (LOD) were in the range of 0.24-0.82 μg L -1 . Low matrix effects were observed in the analysis of thiophene compounds in seawater making the method suitable for use in fresh and saline waters without modification. Acceptable reproducibility was obtained for analysis of thiophene compounds from spiked seawater samples at RSDs ≤7.0% (n = 3).

  19. A gas-phase chemiluminescence-based analyzer for waterborne arsenic

    USGS Publications Warehouse

    Idowu, A.D.; Dasgupta, P.K.; Genfa, Z.; Toda, K.; Garbarino, J.R.

    2006-01-01

    We show a practical sequential injection/zone fluidics-based analyzer that measures waterborne arsenic. The approach is capable of differentiating between inorganic As(III) and As(V). The principle is based on generating AsH 3 from the sample in a confined chamber by borohydride reduction at controlled pH, sparging the chamber to drive the AsH3 to a small reflective cell located atop a photomultiplier tube, allowing it to react with ozone generated from ambient air, and measuring the intense chemiluminescence that results. Arsine generation and removal from solution results in isolation from the sample matrix, avoiding the pitfalls encountered in some solution-based analysis techniques. The differential determination of As(III) and As(V) is based on the different pH dependence of the reducibility of these species to AsH3. At pH ???1, both As(III) and As(V) are quantitatively converted to arsine in the presence of NaBH4. At a pH of 4-5, only As(III) is converted to arsine. In the present form, the limit of detection (S/N = 3) is 0.05 ??g/L As at pH ???1 and 0.09 ??g/L As(III) at pH ???4-5 for a 3-mL sample. The analyzer is intrinsically automated and requires 4 min per determination. It is also possible to determine As(III) first at pH 4.5 and then determine the remaining As in a sequential manner; this requires 6 min. There are no significant practical interferences. A new borohydride solution formulation permits month-long reagent stability. ?? 2006 American Chemical Society.

  20. Radical production from photosensitization of imidazoles, benzophenone and 4-benzoylbenzoic acid

    NASA Astrophysics Data System (ADS)

    Corral Arroyo, Pablo; González, Laura; Steimer, Sarah; Volkamer, Rainer; George, Christian; Bartels-Rausch, Thorsten; Ammann, Markus

    2016-04-01

    Reactions promoted by light are key in atmospheric chemistry. Some of them occur in the condensed phase of aerosols which may contain light absorbing organic compounds that provoke photochemical reactions such as humic like material (GEORGE 2005). Our aim is to understand the role these reactions play in atmospheric photochemistry. This work explores the radical reactions initiated by UV light in mixtures of citric acid (CA) and imidazole-2-carboxaldehyde (IC), benzophenone and 4-Benzoylbenzoic acid (BBA) using NO as a probe molecule for HO2, by means of coated wall flow tube experiments. The loss of NO was measured by a chemiluminescence detector (CLD), also configured for the distinction of the products (HONO or NO2). The dependence of the NO loss on the initial NO concentration, the photosensitizer concentration in the film, relative humidity, light intensity, oxygen molar fraction were investigated as well as the HONO and NO2 yields. We found a clear correlation between the loss of NO above the film and the molar ratio of photosensitizer/CA, and also between the NO loss and the light intensity. The variation of the observed NO loss with oxygen corroborates a mechanism, in which the triplet excited state of the photosensitizer is reduced likely by the predominant donor in the system, citric acid, to a reduced ketyl radical. This reactive species is transferring an electron to molecular oxygen, which in turn leads to production of HO2 radicals, which are released to the gas phase. Therefore, in absence of gas phase oxidants, the loss of NO in the gas phase could be related to the production of HO2 radicals in the condensed phase. Relative humidity had a strong impact on the HO2 output, which shows a maximum value at intermediate humidity around 30%, likely due to different competing effects of dilution and reactant mobility. The observed NO2/HONO ratio was around 1.4 consistent with the secondary chemistry of HO2 in presence of NO in the gas phase, indicating no additional direct release of OH to the gas phase nor direct conversion of NO2 to HONO at the film surface. IC and BBA showed similar HO2 production rates, while the HO2 yield with benzophenone was around 50 times higher. We could preliminary quantify for the first time the contribution of these processes to the oxidative capacity in the atmosphere and conclude that their role is significant for aerosol aging. References George, C., Strekowski, R. S., Kleffmann, J., Stemmler, K., and Ammann, M.: Photoenhanced uptake of gaseous NO2 on solid organic compounds: a photochemical source of HONO?, Faraday Discussions, 130, 195, 2005.

  1. Chemiluminescence of neutrophiles stimulated by opsonized Zymosan in children with bronchial asthma and pneumonia

    NASA Astrophysics Data System (ADS)

    Lewandowicz-Uszynska, A.; Jankowski, A.

    2004-08-01

    Oxygen metabolism of neutrophils after stimulation with opsonized zymosan was examined using chemiluminescence test (in the presence of the patient serum or pooled serum). Into the study 37 children aged from 2 to 12 years were enrolled (20 girls and 17 boys). 10 healthy volunteers comprised the control group (group III). Two groups of patients were established: group I -- children with bronchial asthma (without infection), group II -- children with pneumonia. The examination in both groups was performed twice -- in acute phase and in remission period. The group I in acute phase comprised 16 children and in remission phase 9 children, group II - 21 children in acute phase and 9 children in remission phase, respectively. The following parameters of CL were estimated average value of so called spontaneous CL, maximal excitation of neutrophils after stimulation by zymogen (CLmax), time of zymosan opsonization. The following results were obtained: increased spontaneous CL and CLmax (at the presence of both sera) in acute phase of bronchial asthma and pneumonia in comparison to the control group. In the period of remission both these parameters were insignificantly decreased. The longest time of zymosan opsonization in acute period of disease was observed in children with pneumonia (18 min.). This time did not change during remission phase. Only slightly longer time of opsonization was observed in the patients from group I (in exacerbation) (15 min) than in the control group (13,1 min). This time was prolonged in the clinical remission (20 min).

  2. Parabens determination in cosmetic and personal care products exploiting a multi-syringe chromatographic (MSC) system and chemiluminescent detection.

    PubMed

    Rodas, Melisa; Portugal, Lindomar A; Avivar, Jessica; Estela, José Manuel; Cerdà, Víctor

    2015-10-01

    Parabens are widely used in dairy products, such as in cosmetics and personal care products. Thus, in this work a multi-syringe chromatographic (MSC) system is proposed for the first time for the determination of four parabens: methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP) in cosmetics and personal care products, as a simpler, practical, and low cost alternative to HPLC methods. Separation was achieved using a 5mm-long precolumn of reversed phase C18 and multi-isocratic separation, i.e. using two consecutive mobile phases, 12:88 acetonitrile:water and 28:72 acetonitrile:water. The use of a multi-syringe buret allowed the easy implementation of chemiluminescent (CL) detection after separation. The chemiluminescent detection is based on the reduction of Ce(IV) by p-hydroxybenzoic acid, product of the acid hydrolysis of parabens, to excite rhodamine 6G (Rho 6G) and measure the resulting light emission. Multivariate designs combined with the concepts of multiple response treatments and desirability functions have been employed to simultaneously optimize and evaluate the responses. The optimized method has proved to be sensitive and precise, obtaining limits of detection between 20 and 40 µg L(-1) and RSD <4.9% in all cases. The method was satisfactorily applied to cosmetics and personal care products, obtaining no significant differences at a confidence level of 95% comparing with the HPLC reference method. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Measurement of IL-13–Induced iNOS-Derived Gas Phase Nitric Oxide in Human Bronchial Epithelial Cells

    PubMed Central

    Suresh, Vinod; Mih, Justin D.; George, Steven C.

    2007-01-01

    Exhaled nitric oxide (NO) is altered in numerous diseases including asthma, and is thought broadly to be a noninvasive marker of inflammation. However, the precise source of exhaled NO has yet to be identified, and the interpretation is further hampered by significant inter-subject variation. Using fully differentiated normal human bronchial epithelial (NHBE) cells, we sought to determine (1) the rate of NO release (flux, pl·s−1.cm−2) into the gas; (2) the effect of IL-13, a prominent mediator of allergic inflammation, on NO release; and (3) inter-subject/donor variability in NO release. NHBE cells from three different donors were cultured at an air–liquid interface and stimulated with different concentrations of IL-13 (0, 1, and 10 ng/ml) for 48 h. Gas phase NO concentrations in the headspace over the cells were measured using a chemiluminescence analyzer. The basal NO flux from the three donors (0.05 ± 0.03) is similar in magnitude to that estimated from exhaled NO concentrations, and was significantly increased by IL-13 in a donor-specific fashion. The increase in NO release was strongly correlated with inducible nitric oxide synthase (iNOS) gene and protein expression. There was a trend toward enhanced production of nitrate relative to nitrite as an end product of NO metabolism in IL-13–stimulated cells. NO release from airway epithelial cells can be directly measured. The rate of release in response to IL-13 is strongly dependent on the individual donor, but is primarily due to the expression of iNOS. PMID:17347445

  4. Need total sulfur content? Use chemiluminescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kubala, S.W.; Campbell, D.N.; DiSanzo, F.P.

    Regulations issued by the United States Environmental Protection Agency require petroleum refineries to reduce or control the amount of total sulfur present in their refined products. These legislative requirements have led many refineries to search for online instrumentation that can produce accurate and repeatable total sulfur measurements within allowed levels. Several analytical methods currently exist to measure total sulfur content. They include X-ray fluorescence (XRF), microcoulometry, lead acetate tape, and pyrofluorescence techniques. Sulfur-specific chemiluminescence detection (SSCD) has recently received much attention due to its linearity, selectivity, sensitivity, and equimolar response. However, its use has been largely confined to the areamore » of gas chromatography. This article focuses on the special design considerations and analytical utility of an SSCD system developed to determine total sulfur content in gasoline. The system exhibits excellent linearity and selectivity, the ability to detect low minimum levels, and an equimolar response to various sulfur compounds. 2 figs., 2 tabs.« less

  5. Sensitized chemiluminescence of 2-phenyl-4,5-di(2-furyl)-1H-imidazole/K₃Fe(CN)₆/propyl gallate system combining with solid-phase extraction for the determination of propyl gallate in edible oil.

    PubMed

    Kang, Jing; Han, Lu; Chen, Zhonglin; Shen, Jimin; Nan, Jun; Zhang, Yihua

    2014-09-15

    In this paper, a novel chemiluminescence (CL) method has been developed for the determination of propyl gallate (PG). The proposed method was based on the enhancing effect of PG on the CL signal of 2-phenyl-4,5-di(2-furyl)-1H-imidazole (PDFI) and K3Fe(CN)6 reaction in an alkaline solution. Under the optimum conditions, the enhanced CL intensity was linearly related to the concentration of PG. The linear range of the calibration curve was 0.05-8 μg/mL, and the corresponding detection limit (3σ) was 0.036 μg/mL. The relative standard deviation for determining 1.0 μg/mL PG was 2.8% (n=11). The proposed method has been successfully applied to the determination of PG in edible oil. The edible oil samples were prepared by the solid-phase extraction (SPE) with a C18 column served as the stationary phase. Furthermore, the possible CL mechanism was also discussed briefly based on the photoluminescence (PL) and CL spectra. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Opening a Gateway for Chemiluminescence Cell Imaging: Distinctive Methodology for Design of Bright Chemiluminescent Dioxetane Probes

    PubMed Central

    2017-01-01

    Chemiluminescence probes are considered to be among the most sensitive diagnostic tools that provide high signal-to-noise ratio for various applications such as DNA detection and immunoassays. We have developed a new molecular methodology to design and foresee light-emission properties of turn-ON chemiluminescence dioxetane probes suitable for use under physiological conditions. The methodology is based on incorporation of a substituent on the benzoate species obtained during the chemiexcitation pathway of Schaap’s adamantylidene–dioxetane probe. The substituent effect was initially evaluated on the fluorescence emission generated by the benzoate species and then on the chemiluminescence of the dioxetane luminophores. A striking substituent effect on the chemiluminescence efficiency of the probes was obtained when acrylate and acrylonitrile electron-withdrawing groups were installed. The chemiluminescence quantum yield of the best probe was more than 3 orders of magnitude higher than that of a standard, commercially available adamantylidene–dioxetane probe. These are the most powerful chemiluminescence dioxetane probes synthesized to date that are suitable for use under aqueous conditions. One of our probes was capable of providing high-quality chemiluminescence cell images based on endogenous activity of β-galactosidase. This is the first demonstration of cell imaging achieved by a non-luciferin small-molecule probe with direct chemiluminescence mode of emission. We anticipate that the strategy presented here will lead to development of efficient chemiluminescence probes for various applications in the field of sensing and imaging. PMID:28470053

  7. [Peripheral blood cells luminol-dependent chemiluminescence at the different stages of atopic dermatitis].

    PubMed

    Elistratova, I V; Morozov, S G; Zakharova, I A; Tarasova, M V

    2015-01-01

    Aim of this work was to record the luminol-dependent spontaneous and induced chemiluminescence at the different stages of atopic dermatitis. Peripheral blood cells were obtained from adult patient with atopic dermatitis followed by the registration of luminol-dependent chemiluminescence on luminograph. Opsonized zymosan as well as yeasts Candida tropicalis have been used to induce the chemiluminescence. Spontaneous and induced chemiluminescence were slightly elevated at the mild atopic dermatitis but were decreased at the severe stage of disease. Statistically significant difference has been found between group with mild and severe atopic dermatitis, Skin contamination by yeasts Candida tropicalis causes the increased level of blood cells chemiluminescence at the first week of atopic relapse when the disease was mild. Severe stage of atopic dermatitis was coupled with statistically significant inhibition of both, spontaneous and induced chemiluminescence. Luminol-dependent chemiluminescence of peripheral blood cells from adult atopic dermatitis patients may be stimulated at the mild stage and suppressed at severe stage of atopic dermatitis.

  8. Imaging of Combustion Species in a Radially-Staged Gas Turbine Combustor

    NASA Technical Reports Server (NTRS)

    Locke, Randy J.; Hicks, Yolanda R.; Anderson, Robert C.; Ockunzzi, Kelly A.; Schock, Harold J.

    1996-01-01

    Plannar laser-induced fluorescence (PLIF) is used to characterize the complex flowfield of a unique fuel-lean, radially-staged high pressure gas turbine combustor. PLIF images of OH are presented for two fuel injector configurations. PLIF images of NO, the first acquired at these conditions, are presented and compared with gas sample extraction probe measurements. Flow field imaging of nascent C2 chemiluminescence is also investigated. An examination is made of the interaction between adjoining lean premixed prevaporized (LPP) injectors. Fluorescence interferences at conditions approaching 2000 K and 15 atm are observed and attributed to polycyclic aromatic hydrocarbon (PAH) emissions. All images are acquired at a position immediately downstream of the fuel injectors with combustor burning JP-5 fuel.

  9. Imaging of Combustion Species in a Radially-Staged Gas Turbine Combustor

    NASA Technical Reports Server (NTRS)

    Locke, Randy J.; Hicks, Yolanda R.; Anderson, Robert C.; Ockunzzi, Kelly A.; Schock, Harold J.

    1996-01-01

    Planar laser-induced fluorescence (PLIF) is used to characterize the complex flowfield of a unique fuel-lean, radially-staged, high pressure gas turbine combustor. PLIF images of OH are presented for two fuel injector configurations. PLIF images of NO, the first acquired at these conditions, are presented and compared with gas sample extraction probe measurements. Flow field imaging of nascent C2 chemiluminescence is also investigated. An examination is made of the interaction between adjoining lean premixed prevaporized (LPP) injectors. Fluorescence interferences at conditions approaching 2000 K and 15 atm are observed and attributed to polycyclic aromatic hydrocarbon (PAH) emissions. All images are acquired at a position immediately downstream of the fuel injectors with the combustor burning JP-5 fuel.

  10. Novel and versatile solid-state chemiluminescence sensor based on TiO2-Ru(bpy)32+ nanoparticles for pharmaceutical drugs detection

    NASA Astrophysics Data System (ADS)

    Al-Hetlani, Entesar; Amin, Mohamed O.; Madkour, Metwally

    2018-02-01

    This work describes a novel and versatile solid-state chemiluminescence sensor for analyte detection using TiO2-Ru(bpy)32+-Ce(IV). Herein, we report the synthesis, characterization, optimization and application of a new type of hybrid nanoparticles (NPs). Mesoporous TiO2-Ru(bpy)32+ NPs were prepared using a modified sol-gel method by incorporating Ru(bpy)32+ into the initial reaction mixture at various concentrations. The resultant bright orange precipitate was characterized via transmission electron microscopy, N2 sorpometry, inductively coupled plasma-optical emission spectrometer (ICP-OES), Raman and UV-Vis spectroscopy techniques. The concentration of Ru(bpy)32+ complex in the NPs was quantified using ICP-OES, and its chemiluminescence (CL) response was measured and compared with the same concentration in the liquid phase using oxalate as model analyte. The results showed that this type of hybrid material exhibited a higher CL signal compared with the liquid phase due to the enlarged surface area of the hybrid NPs ( 149.6 m2/g). The amount of TiO2-Ru(bpy)32+ NPs and the effect of the analyte flow rate were also investigated to optimize the CL signal. The optimized system was further used to detect oxalate and two pharmaceutical drugs, namely, imipramine and promazine. The linear range for both drugs was 1-100 pm with limits of detection (LOD) of 0.1 and 0.5 pm, respectively. This approach is considered to be simple, low cost and facile and can be applied to a wide range of analytes.

  11. Involvement of activated leukocytes in the regulation of plasma levels of acute phase proteins in microgravity simulation experiments

    NASA Astrophysics Data System (ADS)

    Larina, Olga; Bekker, Anna; Turin-Kuzmin, Alexey

    2016-07-01

    Earth-based studies of microgravity effects showed the induction of the mechanisms of acute phase reaction (APR). APR comprises the transition of stress-sensitive protein kinases of macrophages and other responsive cells into the active state and the phosphorylation of transcription factors which in turn stimulate the production of acute-phase reaction cytokines. Leukocyte activation is accompanied by the acceleration of the formation of oxygen radicals which can serve a functional indice of leukocyte cell state. The series of events at acute phase response result in selective changes in the synthesis of a number of secretory blood proteins (acute phase proteins, APPs) in liver cells thus contributing the recovery of homeostasis state in the organism. Earlier experiment with head-down tilt showed the increase in plasma concentrations of two cytokine mediators of acute phase response, tumor necrosis factor-alpha (TNF-alpha) and interleukin-6 (IL-6) being the outcome of the activation of producer cells, foremost, leukocytes. In experiment with 4-day dry immersion chemiluminescent (ChL) reply of the whole blood samples to a test stimulus were studied along with the measurements of plasma levels of APPs, namely, alpha1-antitrypsin (alpha1-AT), alpha1-acid glycoprotein (alpha1-AGP), alpha2-macroglobulin (alpha2-M), ceruloplasmin (Cer), haptoglobin (Hp), C3-complement component (C3), C-reactive protein (CRP). Eight individuals aged 21.2 ± 3.2 years were the test subjects in the investigation. Protein studies showed a noticeable increase in the mean plasma levels of all APPs measured in experiment thus producing the evidence of the activation of acute phase response mechanisms while individual patterns revealed variability during the immersion period. The overall trends were similar to these in the previous immersion series. The augment in the strength of signal in stimulated light emission tests was higher after 1- and 2-day of immersion exposure than before the experiment. The effects obtained in this survey suggest the enhancement of the synthesis of active oxygen species by blood phagocytes at the initial stages of adaptation to immersion conditions. The gain of chemiluminescence signal correlated with maximal augment in APP concentrations registered in the course of 4-day immersion. Moreover, in the only case with zero effects in chemiluminescent reply stable APP levels were obtained. The data from functional studies performed with phagocytic cells in the experiment with dry immersion corroborate their implication in acute phase mechanisms participating in the adaptation to simulated microgravity conditions.

  12. Method of generating chemiluminescent light

    DOEpatents

    Spurlin, S.R.; Yeung, E.S.

    1986-03-11

    A method of chemiluminescently determining a sulfide which is either hydrogen sulfide or methyl mercaptan by reacting the sulfide with chlorine dioxide at low pressure and under conditions which allow a longer reaction time in emission of a single photon for every two sulfide containing species, and thereafter, chemiluminescently detecting and determining the sulfide. The invention also relates not only to the detection method, but the novel chemical reaction that generates chemiluminescent light and a specifically designed chemiluminescence detection cell for the reaction. 4 figs.

  13. Method of generating chemiluminescent light

    DOEpatents

    Spurlin, Stanford R.; Yeung, Edward S.

    1986-01-01

    A method of chemiluminescently determining a sulfide which is either hydrogen sulfide or methyl mercaptan by reacting the sulfide with chlorine dioxide at low pressure and under conditions which allow a longer reaction time in emission of a single photon for every two sulfide containing species, and thereafter, chemiluminescently detecting and determining the sulfide. The invention also relates not only to the detection method, but the novel chemical reaction that generates chemiluminescent light and a specifically designed chemiluminescence detection cell for the reaction.

  14. Advanced FT-IR Gas Analysis

    DTIC Science & Technology

    2005-12-01

    fired turbine engine before and after a SCONOx unit which removes NOx and CO from the exhaust stream. A traditional chemiluminescence detector (CLD...was also set up to only measure the emissions after the SCONOx unit for comparison. Unfortunately no CLD data was supplied to AFR for comparison...before and after the SCONOx unit, as well as, measuring accurately 4.1 and 9.01 ppm NO calibration checks (taking the overall average of all the

  15. Multi-angular Flame Measurements and Analysis in a Supersonic Wind Tunnel Using Fiber-Based Endoscopes

    DTIC Science & Technology

    2016-09-14

    angular Flame Measurements and Analysis in a Supersonic Wind Tunnel Using Fiber-Based Endoscopes This paper reports new measurements and analysis made in...the Research Cell 19 super- sonic wind -tunnel facility housed at the Air Force Research Laboratory. The measure- ments include planar chemiluminescence...ASME for publication in the JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER. Manuscript received July 14, 2015; final manuscript received July 30

  16. The Applications of Gold Nanoparticle-Initialed Chemiluminescence in Biomedical Detection

    NASA Astrophysics Data System (ADS)

    Liu, Zezhong; Zhao, Furong; Gao, Shandian; Shao, Junjun; Chang, Huiyun

    2016-10-01

    Chemiluminescence technique as a novel detection method has gained much attention in recent years owning to the merits of high sensitivity, wider linear ranges, and low background signal. Similarly, nanotechnology especially for gold nanoparticles has emerged as detection tools due to their unique physical and chemical properties. Recently, it has become increasingly popular to couple gold nanoparticles with chemiluminescence technique in biological agents' detection. In this review, we describe the superiority of both chemiluminescence and gold nanoparticles and conclude the different applications of gold nanoparticle-initialed chemiluminescence in biomedical detection.

  17. The chemiluminescent response of human monocytes to red cells sensitized with monoclonal anti-Rh(D) antibodies.

    PubMed

    Hadley, A G; Kumpel, B M; Merry, A H

    1988-01-01

    Luminol-enhanced chemiluminescence (CL) was used to assess the metabolic response of human monocytes to red cells sensitized with known amounts of anti-Rh(D). Monoclonal antibodies were used to facilitate a comparison between the functional activities of IgG1 and IgG3 subclasses. The detection of CL provided a simple, rapid and semi-quantitative means of measuring monocyte response to sensitized red cells (IgG-RBC). Monocyte response to IgG3-RBC was quantitatively greater, more rapid and less susceptible to inhibition by fluid phase IgG than monocyte response to IgG1-RBC. The minimum levels of sensitization required to elicit CL from monocytes were approximately 2500 IgG3 molecules per red cell, or approximately 5000 IgG1 molecules per cell.

  18. Quantitative determination of aqueous-phase ozone by chemiluminescence using indigo-5,5'-disulfonate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeuchi, K.; Ibusuki, T.

    1989-03-15

    Indigo-5,5'-disulfonate (IDS) was found to be an efficient reagent for the determination of ozone by chemiluminescence (CL); hence it was applied to the continuous measurements of dissolved ozone (O/sub 3/(aq)). The optimum reagent composition was determined as 10 mg L-1 IDS plus 2 mM phosphate (pH 7.2). The CL intensity was proportional to the O/sub 3/(aq) concentration in the range of 0.025-410 ng mL-1. The detection limit was 0.006 ng mL-1, which is 3 orders of magnitude lower than that obtained by spectrophotometry using IDS as reported previously. The reduction of interferences from aldehydes and hydrogen peroxide was attempted. Furthermore,more » the mechanism of the CL was discussed from CL and fluorescence spectra measured.« less

  19. Flow Injection Technique for Biochemical Analysis with Chemiluminescence Detection in Acidic Media

    PubMed Central

    Chen, Jing; Fang, Yanjun

    2007-01-01

    A review with 90 references is presented to show the development of acidic chemiluminescence methods for biochemical analysis by use of flow injection technique in the last 10 years. A brief discussion of both the chemiluminescence and flow injection technique is given. The proposed methods for biochemical analysis are described and compared according to the used chemiluminescence system.

  20. Development of a chemiluminescence competitive PCR for the detection and quantification of parvovirus B19 DNA using a microplate luminometer.

    PubMed

    Fini, F; Gallinella, G; Girotti, S; Zerbini, M; Musiani, M

    1999-09-01

    Quantitative PCR of viral nucleic acids can be useful clinically in diagnosis, risk assessment, and monitoring of antiviral therapy. We wished to develop a chemiluminescence competitive PCR (cPCR) for parvovirus B19. Parvovirus DNA target sequences and competitor sequences were coamplified and directly labeled. Amplified products were then separately hybridized by specific biotin-labeled probes, captured onto streptavidin-coated ELISA microplates, and detected immunoenzymatically using chemiluminescent substrates of peroxidase. Chemiluminescent signals were quantitatively analyzed by a microplate luminometer and were correlated to the amounts of amplified products. Luminol-based systems displayed constant emission but had a higher detection limit (100-1000 genome copies) than the acridan-based system (20 genome copies). The detection limit of chemiluminescent substrates was lower (20 genome copies) than colorimetric substrates (50 genome copies). In chemiluminescence cPCR, the titration curves showed linear correlation above 100 target genome copies. Chemiluminescence cPCR was positive in six serum samples from patients with parvovirus infections and negative in six control sera. The chemiluminescence cPCR appears to be a sensitive and specific method for the quantitative detection of viral DNAs.

  1. Harmful Gas Recognition Exploiting a CTL Sensor Array

    PubMed Central

    Wang, Qihui; Xie, Lijun; Zhu, Bo; Zheng, Yao; Cao, Shihua

    2013-01-01

    In this paper, a novel cataluminescence (CTL)-based sensor array consisting of nine types of catalytic materials is developed for the recognition of several harmful gases, namely carbon monoxide, acetone, chloroform and toluene. First, the experimental setup is constructed by using sensing nanomaterials, a heating plate, a pneumatic pump, a gas flow meter, a digital temperature device, a camera and a BPCL Ultra Weak Chemiluminescence Analyzer. Then, unique CTL patterns for the four types of harmful gas are obtained from the sensor array. The harmful gases are successful recognized by the PCA method. The optimal conditions are also investigated. Finally, experimental results show high sensitivity, long-term stability and good linearity of the sensor array, which combined with simplicity, make our system a promising application in this field. PMID:24113681

  2. Measurement of Total Reactive Nitrogen (Nr) during the FIREX 2016 Lab Study

    NASA Astrophysics Data System (ADS)

    Roberts, J. M.; Liu, Y.; Stockwell, C.; Warneke, C.; Coggon, M.; Franchin, A.; Gilman, J.; De Gouw, J. A.; Jimenez, J. L.; Koss, A.; Krechmer, J. E.; Lerner, B. M.; Middlebrook, A. M.; Sekimoto, K.; Selimovic, V.; Yokelson, R. J.; Yuan, B.; Zarzana, K. J.; Brown, S. S.

    2017-12-01

    Wildfire is a significant source of nitrogen-containing gases and particles to the atmosphere. In addition, a warmer and drier climate is making wildfire an emerging air quality issue in North America. The nitrogen compounds emitted from biomass fires come solely from fuel nitrogen, as a result of pyrolytic and combustion processes, and range from highly reduced (NH3) to highly oxidized (HNO3/NO3-) species. A systematic understanding of the emissions and fate of these compounds is key to quantifying and predicting the role of wild fire in ozone and particle formation, so that wildfire management can be optimized. In addition, many wildfire-derived compounds have unique health impacts that also need to be managed. We have developed a method for the measurement of Total Reactive Nitrogen (Nr = all N-compounds except for N2 and N2O), based on catalytic conversion on a high temperature platinum catalyst, with detection by NO-O3 chemiluminescence. This instrument was fielded during the 2016 FIREX emissions studies at the USFS Missoula, MT., Fire Laboratory, along with a whole suite of measurements of individual gas and particle-phase species. The nitrogen balance of measured emissions will be discussed in the context of fuel-N, fuel type and fire phase (e.g. pyrolysis, flaming, smoldering stages).

  3. A magnetic particles-based chemiluminescence enzyme immunoassay for rapid detection of ovalbumin.

    PubMed

    Feng, Xiao-Li; Ren, Hong-Lin; Li, Yan-Song; Hu, Pan; Zhou, Yu; Liu, Zeng-Shan; Yan, Dong-Ming; Hui, Qi; Liu, Dong; Lin, Chao; Liu, Nan-Nan; Liu, Yan-Yan; Lu, Shi-Ying

    2014-08-15

    Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles-chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol-H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs-CLEIA method had a linear range from 0.31 to 100ng/ml with a detection limit of 0.24ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Chemiluminescents Light Up the Night.

    ERIC Educational Resources Information Center

    Dashiell, Judy

    1997-01-01

    Provides a general description of chemiluminescence and distinguishes between the two types of chemistry that contribute to our understanding of chemiluminescence: fluorescence and the excitation process. Presents an activity that explores the phenomenon. (DDR)

  5. Pediatric and young adult exposure to chemiluminescent glow sticks.

    PubMed

    Hoffman, Robert J; Nelson, Lewis S; Hoffman, Robert S

    2002-09-01

    Although chemiluminescent plastic rods, commonly called "glow sticks" or "light sticks," are typically considered to be minimally toxic or nontoxic, published data about exposure to these products are scarce. To test our hypothesis that exposure to chemiluminescent products is unlikely to result in significant morbidity or mortality and to describe factors associated with exposure by reviewing reports to our urban poison control center of human exposure to chemiluminescent products. Pediatric and young adult exposure to chemiluminescent products reported between January 1, 2000, and April 1, 2001, to our poison control center were evaluated with regard to demographic group, type of product involved, circumstances of exposure, symptoms, and management. Reported routes of exposure (n = 118) included ingestion (n = 108), ocular (n = 9), and dermal exposure (n = 1). Only patients exposed to chemiluminescent fluid from a leaking container reported symptoms (n = 27). Symptoms were limited to transient irritation of the exposure site, and no systemic toxicity occurred. All adults (n = 4) inadvertently ruptured or swallowed intact light sticks while at a dance club or dance party. Most exposure and all adult exposure occurred on holidays or weekends. Most incidences of exposure to chemiluminescent products involve asymptomatic ingestion of fluid that leaks from glow sticks or ingestion of an intact glow stick. Symptoms occur after exposure to chemiluminescent fluid and consist of transient irritation at the site of exposure. The clustering of reported exposure on weekends and in dance clubs and parties coupled with a lack of occupational or workplace exposure suggest that recreational use is a major contributory factor. Exposure to chemiluminescent products infrequently resulted in symptoms and the symptoms reported were minor. Exposure to chemiluminescent products as described is unlikely to cause significant morbidity or mortality.

  6. Detailed Measurement of ORSC Main Chamber Injector Dynamics

    NASA Astrophysics Data System (ADS)

    Bedard, Michael J.

    Improving fidelity in simulation of combustion dynamics in rocket combustors requires an increase in experimental measurement fidelity for validation. In a model rocket combustor, a chemiluminescence based spectroscopy technique was used to capture flame light emissions for direct comparison to a computational simulation of the production of chemiluminescent species. The comparison indicated that high fidelity models of rocket combustors can predict spatio-temporal distribution of chemiluminescent species with trend-wise accuracy. The comparison also indicated the limited ability of OH* and CH* emission to indicate flame heat release. Based on initial spectroscopy experiments, a photomultiplier based chemiluminescence sensor was designed to increase the temporal resolution of flame emission measurements. To apply developed methodologies, an experiment was designed to investigate the flow and combustion dynamics associated with main chamber injector elements typical of the RD-170 rocket engine. A unique feature of the RD-170 injector element is the beveled expansion between the injector recess and combustion chamber. To investigate effects of this geometry, a scaling methodology was applied to increase the physical scale of a single injector element while maintaining traceability to the RD-170 design. Two injector configurations were tested, one including a beveled injector face and the other a flat injector face. This design enabled improved spatial resolution of pressure and light emission measurements densely arranged in the injector recess and near-injector region of the chamber. Experimental boundary conditions were designed to closely replicate boundary conditions in simulations. Experimental results showed that the beveled injector face had a damping effect on pressure fluctuations occurring near the longitudinal resonant acoustic modes of the chamber, implying a mechanism for improved overall combustion stability. Near the injector, the beveled geometry resulted in more acoustic energy into higher frequency modes, while the flat-face geometry excited modes closer to the fundamental longitudinal mode frequency and its harmonics. Multi-scale analysis techniques were used to investigate intermittency and the range of physical scales present in measured signals. Flame light emission measurements confirmed the presence of flame holding in the injector recess in both configurations. Analysis of dynamics in light emission signals showed flame response at the chamber acoustic resonance frequency in addition to non-acoustic modes associated with mixing shear layer dynamics in the injector recess. The first known benchmark quality data sets of such injector dynamics were recorded in each configuration to enable pressure-based validation of high fidelity models of gas-centered swirl coaxial injectors. This work presents a critical contribution to development of validated combustion dynamics predictive tools and to the understanding of gas-centered swirl coaxial injector elements.

  7. N-Hydroxysuccinimide as an effective chemiluminescence coreactant for highly selective and sensitive detection.

    PubMed

    Saqib, Muhammad; Li, Suping; Gao, Wenyue; Majeed, Saadat; Qi, Liming; Liu, Zhongyuan; Xu, Guobao

    2016-12-01

    The development of novel coreactants for chemiluminescence is very important to improve performance and widen its applications without using any other catalyst. N-Hydroxysuccinimide (NHS), a highly popular amine-reactive, activating, or protecting reagent in biochemical applications and organic synthesis, has been explored as an efficient and stable chemiluminescence coreactant for the first time. The chemiluminescence intensity of the newly developed luminol-NHS system is about 22 times higher than that of the traditional luminol-H 2 O 2 system. Chemiluminescence of this system is dramatically enhanced by Co 2+ . This new chemiluminescence system is then applied for the highly selective and ultrasensitive detection of Co 2+ with limit of detection (0.01 nM) better than those of several conventional analytical methods. This system also enables the efficient detection of luminol (LOD = 7 pM) and NHS (LOD = 3.0 μM) with excellent sensitivity. This chemiluminescence method was then also utilized to detect Co 2+ in tap water and blue silica gel with excellent recoveries in the range 99.20-103.07 %. This novel chemiluminescence system has several advantages, including simple, cost-effective, highly sensitive, selective, and wide linear range. We expect that this chemiluminescence system will be a promising candidate for chemical and biological sensing. Graphical Abstract Comparison of CL peak intensities of classical luminol-H 2 O 2 CL system and newly developed luminol-NHS CL system.

  8. Passive micromixer for luminol-peroxide chemiluminescence detection.

    PubMed

    Lok, Khoi Seng; Kwok, Yien Chian; Nguyen, Nam-Trung

    2011-06-21

    This paper reports a microchip with an integrated passive micromixer based on chaotic advection. The micromixer with staggered herringbone structures was used for luminol-peroxide chemiluminescence detection. The micromixer was examined to assess its suitability for chemiluminescence reaction. The relationship between the flow rate and the location of maximum chemiluminescence intensity was investigated. The light intensity was detected using an optical fiber attached along the mixing channel and a photon detector. A linear correlation between chemiluminescence intensity and the concentration of cobalt(ii) ions or hydrogen peroxide was observed. This microchip has a potential application in environmental monitoring for industries involved in heavy metals and in medical diagnostics.

  9. Spatial and temporal control of microwave triggered chemiluminescence: a protein detection platform.

    PubMed

    Previte, Michael J R; Aslan, Kadir; Geddes, Chris D

    2007-09-15

    We have combined the principles of microwave circuitry and antenna design and our recent work in microwave-triggered metal-enhanced chemiluminescence to now "trigger" chemically and enzyme-catalyzed chemiluminescent reactions with spatial and temporal control. With this technology platform, we achieve spatial and temporal control of enzyme and chemically catalyzed chemiluminescence reactions to achieve more than 500-fold increases in "on-demand" photon flux from chemically catalyzed chemiluminescent reactions. We also report a 6-fold increase in photon flux from HRP-catalyzed assays on disposable coverslips functionalized with HRP and placed proximal to the substrates modified with thin-film aluminum triangle disjointed "bow-tie" structures. In addition, we demonstrate the applicability of this technology to develop multiplexed or high-throughput chemiluminescent assays. We also demonstrate the clinical and biological relevance of this technology platform by affixing aluminum structures in proximity to HRP protein immobilized on nitrocellulose to improve the sensitivity for this model Western blot scheme by 50-fold. We believe analytical applications that rely on enzyme-catalyzed chemiluminescence, such as immunoassays, may greatly benefit from this new platform technology.

  10. Optical tomography of fluorophores in dense scattering media based on ultrasound-enhanced chemiluminescence

    NASA Astrophysics Data System (ADS)

    Kobayashi, Masaki; Kikuchi, Naoto; Sato, Akihiro

    2015-01-01

    This letter proposes and demonstrates ultrasound-combined optical imaging in dense scattering media. A peroxyoxalate chemiluminescence system that includes fluorophores to chemically excite the pigment is stimulated by ultrasound irradiation with power of less than 0.14 W/cm2. Using focused ultrasound, the chemiluminescence is selectively spatially enhanced, which leads to imaging of the pigment when embedded in a light-scattering medium via scanning of the focal point. The ultrasonically enhanced intensity of the chemiluminescence depends on the base intensity of the chemiluminescence without the applied ultrasound irradiation, which thereby enables quantitative determination of the fluorophore concentration. The authors demonstrate the potential of this method to resolve chemiluminescent targets in a dense scattering medium that is comparable to biological tissue. An image was acquired of a chemiluminescent target that included indocyanine green as the fluorophore embedded at a depth of 20 mm in an Intralipid-10% 200 ml/l solution scattering medium (the reduced scattering coefficient was estimated to be approximately 1.3 mm-1), indicating the potential for expansion of this technique for use in biological applications.

  11. Sulfide chemiluminescence detection

    DOEpatents

    Spurlin, Stanford R.; Yeung, Edward S.

    1985-01-01

    A method of chemiluminescently determining a sulfide which is either hydrogen sulfide or methyl mercaptan by reacting the sulfide with chlorine dioxide at low pressure and under conditions which allow a longer reaction time in emission of a single photon for every two sulfide containing species, and thereafter, chemiluminescently detecting and determining the sulfide. The invention also relates not only to the detection method, but the novel chemical reaction and a specifically designed chemiluminescence detection cell for the reaction.

  12. Enhancement effect on the chemiluminescence of acridinium esters under neutral conditions.

    PubMed

    Nakazono, Manabu; Nanbu, Shinkoh

    2018-03-01

    Enhancement effect on the chemiluminescence of acridinium ester derivatives under neutral conditions was investigated. Additions of phenols did not enhance the chemiluminescence intensities of acridinium ester derivatives in the presence of horseradish peroxidase and hydrogen peroxide. Additions of cetyltrimethylammonium bromide apparently enhanced the chemiluminescence intensities of phenyl 10-methyl-10λ 4 -acridine-9-carboxylate derivatives with electron-withdrawing groups at the 4-position of the phenyl group. In particular, the chemiluminescence intensity of 4-(trifluoromethyl)phenyl 10-methyl-10λ 4 -acridine-9-carboxylate trifluoromethanesulfonate salt was 5.5 times stronger in the presence of cetyltrimethylammonium bromide than in its absence at pH 7. The chemiluminescence intensity of 3,4-dicyano-phenyl 10-methyl-10λ 4 -acridine-9-carboxylate trifluoromethanesulfonate salt was 46 times stronger in the presence of cetyltrimethylammonium bromide at pH 7 than in its absence at pH 10. Copyright © 2017 John Wiley & Sons, Ltd.

  13. The Properties of Oxygen Investigated with Easily Accessible Instrumentation: The "One-Photon-Two-Molecule" Mechanism Revisited

    ERIC Educational Resources Information Center

    Adelhelm, Manfred; Aristov, Natasha; Habekost, Achim

    2010-01-01

    The physical properties of oxygen, in particular, the blue color of the liquid phase, the red glow of its chemiluminescence, and its paramagnetism as shown by the entrapment or deflection of liquid oxygen by a magnetic field, can be investigated in a regular school setting with hand-held spectrophotometers and digital cameras. In college-level…

  14. Molecular epidemiology of nga and NAD glycohydrolase/ADP-ribosyltransferase activity among Streptococcus pyogenes causing streptococcal toxic shock syndrome.

    PubMed

    Stevens, D L; Salmi, D B; McIndoo, E R; Bryant, A E

    2000-10-01

    Severe invasive group A streptococcal (GAS) infections emerged in the late 1980s, yet no single virulence factor has been common to all isolates from infected patients. A strong association was recently found between isolates of such cases (regardless of M type) and the production of NAD glycohydrolase (NADase). Of interest, all M-1 strains isolated after 1988 were positive for NADase, whereas virtually all M-1 GAS were previously negative for NADase. Genetic analysis demonstrated that GAS isolates were >96% identical in nga and >99% identical in their upstream regulatory sequences. Furthermore, because NADase-negative strains did not produce immunoreactive NADase, we concluded that additional regulatory element(s) control NADase production. NADase purified from GAS altered neutrophil-directed migration and chemiluminescence responses and had potent ADP-ribosyltransferase activity. In summary, the temporal relationship of NADase expression, alone or with other streptococcal virulence factors, may contribute to the pathogenesis of invasive GAS infections.

  15. Plant cell plasma membrane structure and properties under clinostatting

    NASA Astrophysics Data System (ADS)

    Polulakh, Yu. A.; Zhadko, S. I.; Klimchuk, D. A.; Baraboy, V. A.; Alpatov, A. N.; Sytnik, K. M.

    Structural-functional organization of plasma membrane of pea roots seedling was investigated by methods of chemiluminescence, fluorescence probes, chromatography and freeze-fracture studies under normal conditions and clinostatting. Phase character of lipid peroxidation intensity was fixed. The initial phase of this process is characterized by lipid peroxidation decreasing with its next induction. The primary changes depending on free-radical mechanisms of lipid peroxidation were excellently revealed by chemiluminescence. Plasmalemma microviscosity increased on the average of 15-20 % under microgravity at the initial stages of its phenomenon. There were major changes of phosphatidilcholine and phosphatidilethanolamine contents. The total quantity of phospholipids remained rather stable. Changes of phosphatide acid concentration point to degradation and phospholipids biosynthesis. There were increases of unsaturated fatty acids mainly at the expense of linoleic and linolenic acids and also a decrease of saturated fatty acid content at the expense of palmitic and stearic acids. Unsaturation index of fatty acids increased as well. On the whole fatty acid composition was variable in comparison with phospholipids. Probably it is one of mechanisms of maintaining of microviscosity within definite limits. Considerable structural changes in organization of plasmalemma protein-lipid complex were not revealed by the freeze-fracture studies.

  16. [Establishment of chemiluminescent enzyme immunoassay for detecting antibodies against foot-and-mouth disease virus serotype O in swine].

    PubMed

    Cui, Chen; Huang, Ligang; Li, Jing; Zou, Xingqi; Zhu, Yuanyuan; Xie, Lei; Zhao, Qizu; Yang, Limin; Liu, Wenjun

    2016-11-25

    Recombinant structural protein VP1 of foot-and-mouth disease virus serotype O was expressed in Escherichia coli and then purified using Nickel affinity chromatography. A chemiluminescent enzyme immunoassay (CLEIA) method was established using the purified recombinant protein as coating antigen to detect antibody of foot-and-mouth disease virus serotype O in swine. The specificity of VP1-CLEIA method is 100%. The coefficients of variation in the plate and between plates are 1.10%-6.70% and 0.66%-4.80%, respectively. Comparing with the commercial indirect ELISA kit or liquid phase block ELISA kit, the calculated coincidence rate is 93.50% or 94.00%. The high specificity and stability suggested this detection method can be used to monitor the antibody level of foot-and-mouth disease virus serotype O in swine.

  17. Determination of itopride hydrochloride by high-performance liquid chromatography with Ru(bpy)3(2+) electrogenerated chemiluminescence detection.

    PubMed

    Sun, Yonghua; Zhang, Zhujun; Xi, Zhijun; Shi, Zuolong; Tian, Wei

    2009-08-26

    In this work, a stable electrogenerated chemiluminescence (ECL) detector was developed. The detector was prepared by packing cation-exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)(3)(2+) can be compensated by adding a small amount of Ru(bpy)(3)(2+) into solution phase. Coupled with high-performance liquid chromatography separation, the detector has been used for determination of itopride hydrochloride in human serum. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of itopride hydrochloride in the range of 1.0 x 10(-8) g mL(-1) to 1.0 x 10(-6) g mL(-1) and the detection limit was 3 x 10(-9) g mL(-1) (S/N=3). The as-prepared ECL detector displayed good sensitivity and stability.

  18. Measurement Techniques and Instruments Suitable for Life-prediction Testing of Photovoltaic Arrays

    NASA Technical Reports Server (NTRS)

    Noel, G. T.; Wood, V. E.; Mcginniss, V. D.; Hassell, J. A.; Richard, N. A.; Gaines, G. B.; Carmichael, D. C.

    1979-01-01

    The validation of a 20-year service life for low-cost photovoltaic arrays is a critical requirement in the Low-Cost Solar Array (LSA) Project. The validation is accomplished through accelerated life-prediction tests. A two-phase study was conducted to address the needs before such tests are carried out. The results and recommended techniques from the Phase 1 investigation are summarized in the appendix. Phase 2 of the study is covered in this report and consisted of experimental evaluations of three techniques selected from these recommended as a results of the Phase 1 findings. The three techniques evaluated were specular and nonspecular optical reflectometry, chemiluminescence measurements, and electric current noise measurements.

  19. Sulfide chemiluminescence detection

    DOEpatents

    Spurlin, S.R.; Yeung, E.S.

    1985-11-26

    A method is described for chemiluminescently determining a sulfide which is either hydrogen sulfide or methyl mercaptan by reacting the sulfide with chlorine dioxide at low pressure and under conditions which allow a longer reaction time in emission of a single photon for every two sulfide containing species, and thereafter, chemiluminescently detecting and determining the sulfide. The invention also relates not only to the detection method, but the novel chemical reaction and a specifically designed chemiluminescence detection cell for the reaction. 4 figs.

  20. Apparatus for use in sulfide chemiluminescence detection

    DOEpatents

    Spurlin, Stanford R.; Yeung, Edward S.

    1987-01-01

    A method of chemiluminescently determining a sulfide which is either hydrogen sulfide or methyl mercaptan by reacting the sulfide with chlorine dioxide at low pressure and under conditions which allow a longer reaction time in emission of a single photon for every two sulfide containing species, and thereafter, chemiluminescently detecting and determining the sulfide. The invention also relates not only to the detection method, but the novel chemical reaction and a specifically designed chemiluminescence detection cell for the reaction.

  1. Lucigenin-dependent chemiluminescence in articular chondrocytes.

    PubMed

    Rathakrishnan, C; Tiku, M L

    1993-08-01

    We were recently able to measure intracellular levels of hydrogen peroxide within normal articular chondrocytes using the trapped indicator 2',7'-dichlorofluorescein diacetate. Further studies have shown that stimulated chondrocytes produce luminol-dependent chemiluminescence, suggesting that these cells produce hydrogen peroxide and singlet oxygen. In the present study, we have investigated the lucigenin-dependent chemiluminescence response in normal articular chondrocytes. Chondrocytes either in suspension or adhered to cover slips showed lucigenin-dependent chemiluminescence. There was a dose-dependent increase in chemiluminescence response when chondrocytes were incubated with soluble stimuli like phorbol-myristate-acetate, concanavalin A, and f-met-leu-phe. Catalase and the metabolic inhibitor, sodium azide, which inhibits the enzyme myeloperoxidase, had no inhibitory effect on lucigenin-dependent chemiluminescence production. Only the antioxidant, superoxide dismutase, prevented lucigenin-dependent chemiluminescence, indicating that this assay measures the production of superoxide anions by chondrocytes. We confirmed that chondrocytes release superoxide radicals using the biochemical assay of ferricytochrome c reduction. Since cartilage tissue is semi-transparent, we were able to measure chemiluminescence response in live cartilage tissue, showing that chondrocytes which are embedded within the matrix can also generate superoxide anion radicals. Reactive oxygen intermediates have been shown to play a significant role in the degradation of matrix in arthritis. Our previous and present studies suggest that oxygen radicals produced by chondrocytes may be an important mechanism by which chondrocytes induce cartilage matrix degradation.

  2. Yields of O2(b 1 Sigma g +) from reactions of HO2. [in planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Keyser, L. F.; Choo, K. Y.; Leu, M. T.

    1985-01-01

    The production of O2(b 1 Sigma g +) has been monitored for several reactions of the HO2 radical at 300 K using a discharge-flow apparatus with resonance fluorescence and chemiluminescence detection. In all cases, the resulting quantum efficiencies were found to be less than 0.03. O2(b) was observed when F atoms were added to H2O2 in the gas phase. The signal strengths of O2(b) were proportional to initial concentrations of HO2 formed by the F + H2O2 reaction. Observed /O2(b)/, /HO2/, and /OH/ vs /F/0 were analyzed using a simple three-step mechanism and a more complete computer simulation with 22 reaction steps. The results indicate that the F + HO2 reaction yields O2(b) with an efficiency of (3.6 + or - 1.4) x 10 to the -3rd. Yields from the O + OH2 reaction were less than 0.02, indicating that this reaction cannot be a major source of the O2(b) emission observed in the earth's nightglow.

  3. Sensitive, Selective Test For Hydrazines

    NASA Technical Reports Server (NTRS)

    Roundbehler, David; Macdonald, Stephen

    1993-01-01

    Derivatives of hydrazines formed, then subjected to gas chromatography and detected via chemiluminescence. In method of detecting and quantifying hydrazine vapors, vapors reacted with dinitro compound to enhance sensitivity and selectivity. Hydrazine (HZ), monomethyl hydrazine, (MMH), and unsymmetrical dimethylhydrazine (UDMH) analyzed quantitatively and qualitatively, either alone or in mixtures. Vapors collected and reacted with 2,4-dinitrobenzaldehyde, (DNB), making it possible to concentrate hydrazine in derivative form, thereby increasing sensitivity to low initial concentrations. Increases selectivity because only those constituents of sample reacting with DNB concentrated for analysis.

  4. A chemiluminescence method to detect hydroquinone with water-soluble sulphonato-(salen)manganese(III) complex as catalyst.

    PubMed

    Zhang, Guangbin; Tang, Yuhai; Sun, Yang; Yu, Hua; Du, Wei; Fu, Qiang

    2016-02-01

    A water-soluble sulphonato-(salen)manganese(III) complex with excellent catalytic properties was synthesized and demonstrated to greatly enhance the chemiluminescence signal of the hydrogen peroxide - luminol reaction. Coupled with flow-injection technique, a simple and sensitive chemiluminescence method was first developed to detect hydroquinone based on the chemiluminescence system of the hydrogen peroxide-luminol-sulphonato-(salen)manganese(III) complex. Under optimal conditions, the assay exhibited a wide linear range from 0.1 to 10 ng mL(-1) with a detection limit of 0.05 ng mL(-1) for hydroquinone. The method was applied successfully to detect hydroquinone in tap-water and mineral-water, with a sampling frequency of 120 times per hour. The relative standard deviation for determination of hydroquinone was less than 5.6%, and the recoveries ranged from 96.8 to 103.0%. The ultraviolet spectra, chemiluminescence spectra, and the reaction kinetics for the peroxide-luminol-sulphonato-(salen)manganese(III) complex system were employed to study the possible chemiluminescence mechanism. The proposed chemiluminescence analysis technique is rapid and sensitive, with low cost, and could be easily extended and applied to other compounds. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Optical tomography of fluorophores in dense scattering media based on ultrasound-enhanced chemiluminescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kobayashi, Masaki, E-mail: masaki@tohtech.ac.jp; Kikuchi, Naoto; Sato, Akihiro

    This letter proposes and demonstrates ultrasound-combined optical imaging in dense scattering media. A peroxyoxalate chemiluminescence system that includes fluorophores to chemically excite the pigment is stimulated by ultrasound irradiation with power of less than 0.14 W/cm{sup 2}. Using focused ultrasound, the chemiluminescence is selectively spatially enhanced, which leads to imaging of the pigment when embedded in a light-scattering medium via scanning of the focal point. The ultrasonically enhanced intensity of the chemiluminescence depends on the base intensity of the chemiluminescence without the applied ultrasound irradiation, which thereby enables quantitative determination of the fluorophore concentration. The authors demonstrate the potential of thismore » method to resolve chemiluminescent targets in a dense scattering medium that is comparable to biological tissue. An image was acquired of a chemiluminescent target that included indocyanine green as the fluorophore embedded at a depth of 20 mm in an Intralipid-10% 200 ml/l solution scattering medium (the reduced scattering coefficient was estimated to be approximately 1.3 mm{sup −1}), indicating the potential for expansion of this technique for use in biological applications.« less

  6. A Greener Chemiluminescence Demonstration

    ERIC Educational Resources Information Center

    Jilani, Osman; Donahue, Trisha M.; Mitchell, Miguel O.

    2011-01-01

    Because they are dramatic and intriguing, chemiluminescence demonstrations have been used for decades to stimulate interest in chemistry. One of the most intense chemiluminescent reactions is the oxidation of diaryl oxalate diesters with hydrogen peroxide in the presence of a fluorescer. In typical lecture demonstrations, the commercially…

  7. Apparatus for use in sulfide chemiluminescence detection

    DOEpatents

    Spurlin, S.R.; Yeung, E.S.

    1987-01-06

    A method is described for chemiluminescently determining a sulfide which is either hydrogen sulfide or methyl mercaptan by reacting the sulfide with chlorine dioxide at low pressure and under conditions which allow a longer reaction time in emission of a single photon for every two sulfide containing species, and thereafter, chemiluminescently detecting and determining the sulfide. The invention also relates not only to the detection method, but the novel chemical reaction and a specifically designed chemiluminescence detection cell for the reaction. 4 figs.

  8. Cu2+-imprinted cross-linked chitosan resin as micro-column packing materials for online chemiluminescence determination of trace copper.

    PubMed

    Nie, Feng; Hao, Liang; Gao, Mei; Wu, Yingchun; Li, Xinsheng; Yu, Sha

    2011-01-01

    The Cu(2+)-imprinted cross-linked chitosan resin was synthesized and the binding characteristic of the resin to Cu(2+) was evaluated. The prepared resin was packed into a micro-glass column and used as micro-separating column. The micro-separating column was connected into the chemiluminescence flow system and placed in front of the window of the photomultiplier tube. Based on the luminol-hydrogen peroxide chemiluminescence system, a flow injection online chemiluminescence method for determination of trace copper was developed and trace Cu(2+) in complex samples was successfully determined. The proposed method improved the shortcomings of chemiluminescence method's poor selectivity. Copyright © 2010 John Wiley & Sons, Ltd.

  9. Enhanced chemiluminescence for trazodone trace analysis based on acidic permanganate oxidation in concurrent presence of rhodamine 6G.

    PubMed

    Fujimori, Keiichi; Sakata, Yuta; Moriuchi-Kawakami, Takayo; Shibutani, Yasuhiko

    2017-11-01

    A new sensitized chemiluminescence method by acidic permanganate oxidation was developed for the sensitive determination of trazodone. A fluorescent dye as used rhodamine 6G to increase a chemiluminescence intensity. Under optimum conditions, the liner range of the calibration curve was obtained for 1-5000 nmol/L. The limit of detection was calculated from 3σ of a blank was 0.23 nmol/L. The coexistent ions and substances had no interference with the chemiluminescence measurement. The chemiluminescence spectra were measured to elucidate a possible mechanism for the system. The present method was satisfactorily used in the determination of the drugs in pharmaceutical samples and animal serums. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Rapid method for the quantification of hydroquinone concentration: chemiluminescent analysis.

    PubMed

    Chen, Tung-Sheng; Liou, Show-Yih; Kuo, Wei-Wen; Wu, Hsi-Chin; Jong, Gwo-Ping; Wang, Hsueh-Fang; Shen, Chia-Yao; Padma, V Vijaya; Huang, Chih-Yang; Chang, Yen-Lin

    2015-11-01

    Topical hydroquinone serves as a skin whitener and is usually available in cosmetics or on prescription based on the hydroquinone concentration. Quantification of hydroquinone content therefore becomes an important issue in topical agents. High-performance liquid chromatography (HPLC) is the commonest method for determining hydroquinone content in topical agents, but this method is time-consuming and uses many solvents that can become an environmental issue. We report a rapid method for quantifying hydroquinone content by chemiluminescent analysis. Hydroquinone induces the production of hydrogen peroxide in the presence of basic compounds. Hydrogen peroxide induced by hydroquinone oxidized light-emitting materials such as lucigenin, resulted in the production of ultra-weak chemiluminescence that was detected by a chemiluminescence analyzer. The intensity of the chemiluminescence was found to be proportional to the hydroquinone concentration. We suggest that the rapid (measurement time, 60 s) and virtually solvent-free (solvent volume, <2 mL) chemiluminescent method described here for quantifying hydroquinone content may be an alternative to HPLC analysis. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Rapid aptasensor capable of simply diagnosing prostate cancer.

    PubMed

    Cha, Timothy; Cho, Sandy; Kim, Young Teck; Lee, Ji Hoon

    2014-12-15

    Using guanine (G)-rich DNA aptamer-conjugated 6-carboxyfluorescein (6-FAM) capable of rapidly capturing prostate specific antigen (PSA) in human serum, cost-effective and simple biosensor with guanine chemiluminescence detection was developed for early diagnosis of prostate cancer. Free G-rich DNA aptamer-conjugated 6-FAM emits bright light in guanine chemiluminescence reaction based on the principle of chemiluminescent resonance energy transfer (CRET). However, G-rich DNA aptamer-conjugated 6-FAM bound with PSA cannot emit light because PSA acts as a strong interference in CRET between 6-FAM and high-energy intermediate formed from the reaction of 3,4,5-trimethoxylphenylglyoxal (TMPG) and guanine of G-rich DNA aptamer. A chemiluminescent biosensor, developed using the different properties of G-rich DNA aptamer-conjugated 6-FAM in the absence and presence of PSA in guanine chemiluminescence reaction, was able to quantify trace levels of PSA in human serum within 30 min without time-consuming and complicated procedures (e.g., multiple incubation and washings) required for conventional immunoassays operated with expensive and intractable antibodies. The limit of detection of chemiluminescent biosensor having a wide linear dynamic range (1.9-125 ng/ml) was 1.0 ng/ml. The excellent correlation (R=0.985) between chemiluminescent biosensor and conventional enzyme immunoassay indicates that the accurate, precise, and rapid chemiluminescent biosensor can be applied as a new method for early diagnosis of prostate cancer. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Detection of S-nitrosocompounds using mid-IR cavity ringdown spectroscopy

    PubMed Central

    Stsiapura, Vitali I.; Shuali, Vincent K.; Gaston, Benjamin M.; Lehmann, Kevin K.

    2015-01-01

    S-nitrosocompounds have received much attention in biological research. In addition to their role as nitric oxide donors, there is a growing evidence that these compounds are involved in signaling processes in biological systems. Determination of S-nitrosylated proteins is of great importance for fundamental biological research and medical applications. The most common method to assay biological S-nitrosocompounds is to chemically or photochemically reduce SNO- functional groups to release nitric oxide that is then entrained in an inert gas stream and detected, usually through chemiluminescence. We report a method of S-nitrosocompounds detection using cavity ring-down measurements of gaseous NO absorbance at 5.2μ. The proposed method, in contrast to the chemiluminescence-based approach, can be used to distinguish isotopic forms of NO. We demonstrated sensitivity down to ~2 pmole of S-14NO groups and ~5 pmole of S-15NO groups for S-nitrosocompounds in aqueous solutions. The wide dynamic range of cavity ring-down detection allows the measurement of S-nitrosocompounds levels from pico- to nanomole amounts. PMID:25692741

  13. A highly selective chemiluminescent probe for the detection of chromium(VI)

    NASA Astrophysics Data System (ADS)

    Jin, Yan; Sun, Yonghua; Li, Chongying; Yang, Chao

    2018-03-01

    In present work, rhodamine B hydrazide and rhodamine 6G hydrazide were synthesized and the chemiluminescence performance has been investigated. Based on the chemiluminescence of rhodamine 6G hydrazide-chromium(VI), a selective and sensitive method for the direct detection of chromium(VI) was developed. The chemiluminescence intensity was linearly related to the concentration of chromium(VI) in the range of 2.60 × 10- 8-8.00 × 10- 6 mol/L with a correlation coefficient of r = 0.998 and a detection limit of 1.4 × 10- 8 mol/L (S/N = 3). The results indicated rhodamine 6G hydrazide was an excellent chemiluminescent probe for chromium(VI) without reduction of chromium(VI) to chromium(III). A possible mechanism of CL emission was also suggested.

  14. Following glucose oxidase activity by chemiluminescence and chemiluminescence resonance energy transfer (CRET) processes involving enzyme-DNAzyme conjugates.

    PubMed

    Niazov, Angelica; Freeman, Ronit; Girsh, Julia; Willner, Itamar

    2011-01-01

    A hybrid consisting of glucose oxidase-functionalized with hemin/G-quadruplex units is used for the chemiluminescence detection of glucose. The glucose oxidase-mediated oxidation of glucose yields gluconic acid and H(2)O(2). The latter in the presence of luminol acts as substrate for the hemin/G-quadruplex-catalyzed generation of chemiluminescence. The glucose oxidase/hemin G-quadruplex hybrid was immobilized on CdSe/ZnS quantum dots (QDs). The light generated by the hybrid, in the presence of glucose, activated a chemiluminescence resonance energy transfer process to the QDs, resulting in the luminescence of the QDs. The intensities of the luminescence of the QDs at different concentrations of glucose provided an optical means to detect glucose.

  15. Following Glucose Oxidase Activity by Chemiluminescence and Chemiluminescence Resonance Energy Transfer (CRET) Processes Involving Enzyme-DNAzyme Conjugates

    PubMed Central

    Niazov, Angelica; Freeman, Ronit; Girsh, Julia; Willner, Itamar

    2011-01-01

    A hybrid consisting of glucose oxidase-functionalized with hemin/G-quadruplex units is used for the chemiluminescence detection of glucose. The glucose oxidase-mediated oxidation of glucose yields gluconic acid and H2O2. The latter in the presence of luminol acts as substrate for the hemin/G-quadruplex-catalyzed generation of chemiluminescence. The glucose oxidase/hemin G-quadruplex hybrid was immobilized on CdSe/ZnS quantum dots (QDs). The light generated by the hybrid, in the presence of glucose, activated a chemiluminescence resonance energy transfer process to the QDs, resulting in the luminescence of the QDs. The intensities of the luminescence of the QDs at different concentrations of glucose provided an optical means to detect glucose. PMID:22346648

  16. Space shuttle nonmetallic materials age life prediction

    NASA Technical Reports Server (NTRS)

    Mendenhall, G. D.; Hassell, J. A.; Nathan, R. A.

    1975-01-01

    The chemiluminescence from samples of polybutadiene, Viton, Teflon, Silicone, PL 731 Adhesive, and SP 296 Boron-Epoxy composite was measured at temperatures from 25 to 150 C. Excellent correlations were obtained between chemiluminescence and temperature. These correlations serve to validate accelerated aging tests (at elevated temperatures) designed to predict service life at lower temperatures. In most cases, smooth or linear correlations were obtained between chemiluminescence and physical properties of purified polymer gums, including the tensile strength, viscosity, and loss tangent. The latter is a complex function of certain polymer properties. Data were obtained with far greater ease by the chemiluminescence technique than by the conventional methods of study. The chemiluminescence from the Teflon (Halon) samples was discovered to arise from trace amounts of impurities, which were undetectable by conventional, destructive analysis of the sample.

  17. Flow-injection chemiluminescence method for the determination of chloramphenicol based on luminol-sodium periodate order-transform second-chemiluminescence reaction.

    PubMed

    Zhuang, Ya-Feng; Zhu, Sheng-Nan; Wei, Wei; Li, Jie-Li

    2011-01-01

    A new chemiluminescence (CL) reaction was observed when chloramphenicol solution was injected into the mixture after the end of the reaction of alkaline luminol and sodium periodate or sodium periodate was injected into the reaction mixture of chloramphenicol and alkaline luminol. This reaction is described as an order-transform second-chemiluminescence (OTSCL) reaction. The OTSCL method combined with a flow-injection technique was applied to the determination of chloramphenicol. The optimum conditions for the order-transform second-chemiluminescence emission were investigated. A mechanism for OTSCL has been proposed on the basis of the chemiluminescence kinetic characteristics, the UV-visible spectra and the chemiluminescent spectra. Under optimal experimental conditions, the CL response is proportional to the concentration of chloramphenicol over the range 5.0 × 10(-7)-5.0 × 10(-5) mol/L with a correlation coefficient of 0.9969 and a detection limit of 6.0 × 10(-8) mol/L (3σ). The relative standard deviation (RSD) for 11 repeated determinations of 5.0 × 10(-6) mol/L chloramphenicol is 1.7%. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Chemiluminescence of metastable tin with fluorine, chlorine, and nitrogen trifluoride utilizing a beam-gas configuration

    NASA Astrophysics Data System (ADS)

    Rosano, W. J.; Parson, J. M.

    1986-09-01

    This paper reports the observation of electronic chemiluminescence (CL) from the reaction of metastable Sn with F2, Cl2, and NF3. All three reactions produced CL which was identified as emission from the A 2Σ+-X 2Π system of the tin monohalides and was first order with respect to the scattering gas. All spectra were highly congested suggesting that the product monohalides are produced with a large degree of internal excitation. Attenuation studies of various electronic states of metastable Sn in the beam with H2 show the 1D state to be the major contributor to CL product formation. Absolute CL cross sections were determined for Sn(1D) with F2, Cl2, and NF3 to be 67, >0.07, and 0.006 Å2, respectively, with uncertainties of ˜±60%. The cross section for the F2 reaction is approximately 35 times larger than the corresponding reaction for Sn(3P). The prior model, based on product state densities, predicts an increase of only about 6.5. We propose, in light of recent alignment experiments of Ca p orbitals, that the difference in reactivity of 1D and 3P states is a result of the symmetry of the second p orbital on Sn relative to the F2 molecule. Also, the production of the observed CL states requires a nonadiabatic process. Finally, the CL cross sections for the title reactions were found to increase with increasing collision energy.

  19. Direct Real-Time Monitoring of Prodrug Activation by Chemiluminescence.

    PubMed

    Gnaim, Samer; Scomparin, Anna; Das, Sayantan; Blau, Rachel; Satchi-Fainaro, Ronit; Shabat, Doron

    2018-05-22

    The majority of theranostic prodrugs reported so far relay information through a fluorogenic response generated upon release of the active chemotherapeutic agent. A chemiluminescence detection mode offers significant advantages over fluorescence, mainly due to the superior signal-to-noise ratio of chemiluminescence. Here we report the design and synthesis of the first theranostic prodrug monitored by a chemiluminescence diagnostic mode. As a representative model, we prepared a prodrug from the chemotherapeutic monomethyl auristatin E, which was modified for activation by β-galactosidase. The activation of the prodrug in the presence of β-galactosidase is accompanied by emission of a green photon. Light emission intensities, which increase with increasing concentration of the prodrug, were linearly correlated with a decrease in the viability of a human cell line that stably expresses β-galactosidase. We obtained sharp intravital chemiluminescent images of endogenous enzymatic activity in β-galactosidase-overexpressing tumor-bearing mice. The exceptional sensitivity achieved with the chemiluminescence diagnostic mode should allow the exploitation of theranostic prodrugs for personalized cancer treatment. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Subnanogram determination of aniracetam in pharmaceutical preparations and biofluids by flow injection analysis with chemiluminescence detection based on its enhancement of the myoglobin-luminol reaction.

    PubMed

    Shao, Xiaodong; Li, Ying; Li, Fagen; Liu, Yangqin; Song, Zhenghua

    2011-01-01

    A novel flow injection chemiluminescence method with a myoglobin-luminol system is described for determining aniracetam. Myoglobin-bound aniracetam produced a complex that catalyzed the chemiluminescence reaction between luminol and myoglobin, leading to fast chemiluminescence. The chemiluminescence intensity in the presence of aniracetam was remarkably enhanced compared with that in the absence of aniracetam. Under the optimum reaction conditions the chemiluminescence increment produced was proportional to the concentration of aniracetam in the range of 0.1-1000.0 ng/mL (R2 = 0.9992), with a detection limit of 0.03 ng/mL (3delta). At a flow rate of 2.0 mL/min, the whole process, including sampling and washing, could be completed in 0.5 min, offering a sampling efficiency of 120/h; the RSD was less than 3.0% (n = 5). The method was satisfactory for determination of aniracetam in pharmaceutical preparations and human urine and serum samples. A possible mechanism of the reaction is also discussed.

  1. Development of a highly sensitive chemiluminescence enzyme immunoassay using enhanced luminol as substrate.

    PubMed

    Tao, Xiaoqi; Wang, Wenjun; Wang, Zhanhui; Cao, Xingyuan; Zhu, Jinghui; Niu, Lanlan; Wu, Xiaoping; Jiang, Haiyang; Shen, Jianzhong

    2014-06-01

    In this study, a high sensitivity chemiluminescence enzyme immunoassay (CLEIA) based on novel enhancers was developed. Under optimal conditions, we developed an enhanced chemiluminescence reaction (ECR) catalyzed by horseradish peroxidase (HRP-C) in the presence of 3-(10'-phenothiazinyl) propane-1-sulfonate (SPTZ) and 4-morpholinopyridine (MORP) as enhancers. The limit of detection of the newly prepared chemiluminescent cocktail for HRP was 0.33 pg/well, which is lower than that of commercial Super Signal substrate. The results showed that this novel chemiluminescent cocktail can significantly increase the light output of HRP-catalyzed ECR, which can be translated into a corresponding improvement in sensitivity. Similar improvements were observed in CLEIA for the determination of chloramphenicol in milk. In addition, the ECR of N-azoles as secondary enhancer was also presented. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Applications of chemiluminescence to bacterial analysis

    NASA Technical Reports Server (NTRS)

    Searle, N. D.

    1975-01-01

    Luminol chemiluminescence method for detecting bacteria was based on microbial activation of the oxidation of the luminol monoanion by hydrogen peroxide. Elimination of the prior lysing step, previously used in the chemiluminescence technique, was shown to improve considerably the reproducibility and accuracy of the method in addition to simplifying it. An inexpensive, portable photomultiplier detector was used to measure the maximum light intensity produced when the sample is added to the reagent. Studies of cooling tower water show that the luminol chemiluminescence technique can be used to monitor changes in viable cell population both under normal conditions and during chlorine treatment. Good correlation between chemiluminescence and plate counts was also obtained in the analysis of process water used in paper mills. This method showed good potential for monitoring the viable bacteria populations in activated sludge used in waste treatment plants to digest organic matter.

  3. A study of the chemiluminescence behavior of cephalosporins with luminol and its analytical application.

    PubMed

    Niu, Lichuan; Song, Zhenghua; He, Xili

    2009-08-01

    The chemiluminescence intensity of luminol-dissolved oxygen was decreased when cephalosporins were mixed with luminol. The decrease chemiluminescence intensity was linear with the logarithm of cephalosporins concentration over the range from nanogram to microgramme level, with the limits of detection at nanogram level. The sensitivities of determination for cephalosporins were in the order of cefoperazone > ceftriaxone > cefuroxime > cefaclor > cefalexin > cefradine. The proposed method was applied to monitor the excretion of cefradine in human urine after taken cefradine capsules. The possible chemiluminescence mechanism and relationship between the determination sensitivities and generations of cephalosporins were also discussed.

  4. Determination of absolute chemiluminescence quantum yields for reactions of bis-(pentachlorophenyl) oxalate, hydrogen peroxide and fluorescent compounds.

    PubMed

    Catherall, C L; Palmer, T F; Cundall, R B

    1989-01-01

    Absolute chemiluminescence quantum yields (phi CL) for reactions of bis-(pentachlorophenyl) oxalate (PCPO), hydrogen peroxide (H2O2) and 9:10 diphenyl anthracene (DPA) have been determined. A fully corrected chemiluminescence monitoring spectrometer was calibrated for spectral sensitivity using the chemiluminescence of the bis-(pentachlorophenyl) oxalate system as a liquid light source, the total photon output of which had previously been determined by chemical actinometry. At high (PCPO)/(H2O2) ratios phi CL was found to be independent of PCPO and H2O2 concentrations.

  5. General Chemistry Laboratory Experiment to Demonstrate Organic Synthesis, Fluorescence, and Chemiluminescence through Production of a Biphasic Glow Stick

    ERIC Educational Resources Information Center

    Pay, Adam L.; Kovash, Curtiss; Logue, Brian A.

    2017-01-01

    A laboratory experiment is described for beginning, nonmajor chemistry students, which allows students to examine the phenomena of fluorescence and chemiluminescence, as well as gain experience in basic organic synthesis. Students synthesize fluorescein and bis(2,4,6-trichlorophenyl) oxalate (TCPO) to explore fluorescence and chemiluminescence by…

  6. An experimental study of the velocity-forced flame response of a lean-premixed multi-nozzle can combustor for gas turbines

    NASA Astrophysics Data System (ADS)

    Szedlmayer, Michael Thomas

    The velocity forced flame response of a multi-nozzle, lean-premixed, swirl-stabilized, turbulent combustor was investigated at atmospheric pressure. The purpose of this study was to analyze the mechanisms that allowed velocity fluctuations to cause fluctuations in the rate of heat release in a gas turbine combustor experiencing combustion instability. Controlled velocity fluctuations were introduced to the combustor by a rotating siren device which periodically allowed the air-natural gas mixture to flow. The velocity fluctuation entering the combustor was measured using the two-microphone method. The resulting heat release rate fluctuation was measured using CH* chemiluminescence. The global response of the flame was quantified using the flame transfer function with the velocity fluctuation as the input and the heat release rate fluctuation as the output. Velocity fluctuation amplitude was initially maintained at 5% of the inlet velocity in order to remain in the linear response regime. Flame transfer function measurements were acquired at a wide range of operating conditions and forcing frequencies. The selected range corresponds to the conditions and instability frequencies typical of real gas turbine combustors. Multi-nozzle flame transfer functions were found to bear a qualitative similarity to the single-nozzle flame transfer functions in the literature. The flame transfer function gain exhibited alternating minima and maxima while the phase decreased linearly with increasing forcing frequency. Several normalization techniques were applied to all flame transfer function data in an attempt to collapse the data into a single curve. The best collapse was found to occur using a Strouhal number which was the ratio of the characteristic flame length to the wavelength of the forced disturbance. Critical values of Strouhal number are used to predict the shedding of vortical structures in shear layers. Because of the collapse observed when the flame transfer functions are plotted versus Strouhal number, vortical structures are thought to have a strong influence on the response of this multi-nozzle configuration. The structure of heat release rate fluctuations throughout the flame is analyzed using CH* chemiluminescence acquired with a high speed camera. Flames with a similar level of flame transfer function gain are found to exhibit similarity in the spatial distribution of their heat release rate fluctuations, regardless of the operating condition. Flames with high gain are found to have high amplitude fluctuations near the downstream end of the flame, with weak fluctuations near the flame base. The phase of the downstream fluctuations changes minimally across the downstream region, indicating that they occur inphase. Flames with low gain exhibit stronger fluctuations near the flame base, but weak fluctuations in the downstream region. The phase of the fluctuations near the flame base changes continuously along the flame axis, indicating that parts of the flame will fluctuate out-of-phase. Accordingly, from a global perspective, destructive interference between heat release rate fluctuations in different parts of the flame can be expected. The behavior observed in the flame is ascribed to the interaction of acoustic velocity fluctuations, vortical disturbances and swirl fluctuations. The response of the multi-nozzle flame to high amplitude velocity fluctuations was tested for a single operating condition. Based on the global flame response, most frequencies responded linearly over the tested range of amplitudes. Nonlinear effects were found to occur at three frequencies. The behaviors observed at these frequencies matched those observed in the literature and included flame response saturation and mode triggering. For conditions which responded linearly at all amplitudes, the structure of heat release rate fluctuations was found to remain nearly constant. For conditions with nonlinear behavior, the structure of the fluctuations was a function of the forcing amplitude, particularly in the downstream region. The behavior of the multi-nozzle flame was compared directly to that of a single-nozzle flame of the same nozzle design. The multi-nozzle characteristic flame length was found to be on average 10% longer than for the single-nozzle flame. The flame transfer functions from the two cases were found to exhibit qualitative similarity, where the frequencies at which the extrema occur are similar. The actual value of gain for the same operating condition and frequency does, however, vary by more than a factor of two in some cases. The phase value can also vary by as much as pi radians. These differences indicate that single-nozzle flame transfer functions should not be used directly to predict the instability driving force of real gas turbine combustors.

  7. Release of oxygen radicals by articular chondrocytes: a study of luminol-dependent chemiluminescence and hydrogen peroxide secretion.

    PubMed

    Rathakrishnan, C; Tiku, K; Raghavan, A; Tiku, M L

    1992-10-01

    We previously established that normal articular chondrocytes, like macrophages, express class II major histocompatibility antigens, present antigen, and induce mixed and autologous lymphocyte stimulation. In a recent study using the trapped indicator 2',7'-dichlorofluorescein diacetate, we were able to measure levels of intracellular hydrogen peroxide within normal articular chondrocytes (J Immunol 245:690-696, 1990). In the present study, we utilized the technique of chemiluminescence and the biochemical method of quantitating hydrogen peroxide release to measure the production of reactive oxygen intermediates by articular chondrocytes. Chondrocytes, in suspension or adherent to coverslips, showed luminol-dependent chemiluminescence that was dependent on the number and viability of cells. There was a dose-dependent increase in chemiluminescence in response to soluble stimuli, such as phorbol myristate acetate (PMA), concanavalin A (ConA), and f-Met-Leu-Phe (FMLP). Azide inhibited chemiluminescence, suggesting that the light emission in chondrocytes is myeloperoxidase dependent. The antioxidant, catalase, inhibited chemiluminescence but superoxide dismutase had no effect, suggesting that luminol-dependent chemiluminescence in chondrocytes mostly measured hydrogen peroxide. Chemiluminescence was also observed in fragments of live cartilage tissue, indicating that chondrocytes that are cartilage matrix bound can generate the respiratory burst response. Using the scopoletin oxidation assay, we confirmed the release of increasing amounts of hydrogen peroxide by chondrocytes exposed to interleukin-1, rabbit interferon, and tumor necrosis factor alpha. Tumor necrosis factor alpha had both priming and enhancing effects on reactive oxygen intermediate production by chondrocytes. Reactive oxygen intermediates have been shown to play a significant role in matrix degradation. We suggest that reactive oxygen intermediates produced by chondrocytes play an important role in the degradation of matrix in arthritis.

  8. Surface plasmon coupled chemiluminescence during adsorption of oxygen on magnesium surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagemann, Ulrich; Nienhaus, Hermann, E-mail: hermann.nienhaus@uni-due.de

    The dissociative adsorption of oxygen molecules on magnesium surfaces represents a non-adiabatic reaction exhibiting exoelectron emission, chemicurrent generation, and weak chemiluminescence. Using thin film Mg/Ag/p-Si(111) Schottky diodes with 1 nm Mg on a 10-60 nm thick Ag layer as 2π-photodetectors, the chemiluminescence is internally detected with a much larger efficiency than external methods. The chemically induced photoyield shows a maximum for a Ag film thickness of 45 nm. The enhancement is explained by surface plasmon coupled chemiluminescence, i.e., surface plasmon polaritons are effectively excited in the Ag layer by the oxidation reaction and decay radiatively leading to the observed photocurrent.more » Model calculations of the maximum absorption in attenuated total reflection geometry support the interpretation. The study demonstrates the extreme sensitivity and the practical usage of internal detection schemes for investigating surface chemiluminescence.« less

  9. Chemiluminescence involving acidic and ambient ion light emitters. The chemiluminescence of the 9-acridinepercarboxylate anion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, E.H.; Roswell, D.F.; Dupont, A.C.

    The reaction of phenyl 9-acridinecarboxylate with an excess of peroxide ion in THF/water (67/33 mol %) leads to the emission of either bright yellow-green light or bright blue light, depending on the reaction conditions. The blue emission is favored by high concentrations of hydrogen peroxide and water, for example. 9-Acridinepercarboxylic acid is a common intermediate in the reactions. The light emitter responsible for the blue chemiluminescence is acridone, whereas that responsible for the yellow-green chemiluminescence is the anion of acridone. The effects of base concentration and solvent composition on the relative proportions of these two emitters have produced evidence that,more » contrary to the expectation of simple theory, a dioxetanone is not an intermediate in the reaction. Other cases where chemiluminescence may involve percarboxylate and peroxide ions are discussed.« less

  10. Highly luminescent S,N co-doped carbon quantum dots-sensitized chemiluminescence on luminol-H2 O2 system for the determination of ranitidine.

    PubMed

    Chen, Jianqiu; Shu, Juan; Chen, Jiao; Cao, Zhiran; Xiao, An; Yan, Zhengyu

    2017-05-01

    S,N co-doped carbon quantum dots (N,S-CQDs) with super high quantum yield (79%) were prepared by the hydrothermal method and characterized by transmission electron microscopy, photoluminescence, UV-Vis spectroscopy and Fourier transformed infrared spectroscopy. N,S-CQDs can enhance the chemiluminescence intensity of a luminol-H 2 O 2 system. The possible mechanism of the luminol-H 2 O 2 -(N,S-CQDs) was illustrated by using chemiluminescence, photoluminescence and ultraviolet analysis. Ranitidine can quench the chemiluminescence intensity of a luminol-H 2 O 2 -N,S-CQDs system. So, a novel flow-injection chemiluminescence method was designed to determine ranitidine within a linear range of 0.5-50 μg ml -1 and a detection limit of 0.12 μg ml -1 . The method shows promising application prospects. Copyright © 2016 John Wiley & Sons, Ltd.

  11. 3D-printed and CNC milled flow-cells for chemiluminescence detection.

    PubMed

    Spilstead, Kara B; Learey, Jessica J; Doeven, Egan H; Barbante, Gregory J; Mohr, Stephan; Barnett, Neil W; Terry, Jessica M; Hall, Robynne M; Francis, Paul S

    2014-08-01

    Herein we explore modern fabrication techniques for the development of chemiluminescence detection flow-cells with features not attainable using the traditional coiled tubing approach. This includes the first 3D-printed chemiluminescence flow-cells, and a milled flow-cell designed to split the analyte stream into two separate detection zones within the same polymer chip. The flow-cells are compared to conventional detection systems using flow injection analysis (FIA) and high performance liquid chromatography (HPLC), with the fast chemiluminescence reactions of an acidic potassium permanganate reagent with morphine and a series of adrenergic phenolic amines. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Comparison of three gas chromatography methods for the determination of slip agents in polyethylene films.

    PubMed

    Garrido-López, Alvaro; Esquiu, Vanesa; Tena, María Teresa

    2007-05-25

    Polymers require the use of some slip agents, such as oleamide and erucamide, in order to reduce their friction coefficient and to make films easier to handle. In this communication, three analytical methods consisting in pressurized liquid extraction (PLE) and gas chromatography (GC) are used to determine oleamide and erucamide in polyethylene films. The sample was extracted with pure isopropanol (two times) at 105 degrees C for 16 min. Then, the liquid extract containing oleamide and erucamide was analyzed by GC and three different detection systems: flame ionization detector (FID), thermoionic selective detector (TSD) and ion-trap mass spectrometry detector (MSD). Oleamide and erucamide were separated using a 30 m x 0.25 mm (I.D.) 5% phenyl-95% dimethyl-polysiloxane capillary column in 12 min. The chromatographic methods were characterized and compared in terms of repeatability, linearity and sensitivity. The GC-FID and GC-TSD methods were linear up to about 60 microg ml(-1), whereas the linear range for the GC-MSD method was shorter, from 20.5 to 42 microg ml(-1). LODs identified with GC-MSD were two times higher than those identified with the other two methods. Repeatability values (expressed as relative standard deviation) of less than 2.5% were found for FID and TSD but they were above 10% for MSD. Finally, each method was applied to determine the content of erucamide and oleamide in several polyethylene films and the results obtained were compared with those obtained from the nitrogen content measured by pyrolysis and gas-phase chemiluminescence. No significant differences were observed between the results of the methods.

  13. The influence of charge stratification on the spectral signature of partially premixed combustion in a light-duty optical engine

    NASA Astrophysics Data System (ADS)

    Najafabadi, M. Izadi; Egelmeers, Luc; Somers, Bart; Deen, Niels; Johansson, Bengt; Dam, Nico

    2017-04-01

    The origin of light emission during low-temperature combustion in a light-duty IC engine is investigated by high-speed spectroscopy in both HCCI and PPC regimes. Chemiluminescence and thermal radiation are expected to be the dominant sources of light emission during combustion. A method has been developed to distinguish chemiluminescence from thermal radiation, and different chemiluminescing species could be identified. Different combustion modes and global equivalence ratios are analyzed in this manner. The results indicate that the spectral signature (270-540 nm range) of the combustion is highly dependent on the stratification level. A significant broadband chemiluminescence signal is detected and superimposed on all spectra. This broadband chemiluminescence signal can reach up to 100 percent of the total signal in HCCI combustion, while it drops to around 80 percent for stratified combustion (PPC). We show that this broadband signal can be used as a measure for the heat release rate. The broadband chemiluminescence did also correlate with the equivalence ratio quite well in both HCCI and PPC regimes, suggesting that the total emission in the spectral region of 330-400 nm can serve as a proxy of equivalence ratio and the rate of heat release. Regarding C2* chemiluminescence, we see two different chemical mechanisms for formation of C2* in the PPC regime: first during the early stage of combustion by the breakup of bigger molecules and the second during the late stage of combustion when soot particles are forming.

  14. High-speed OH* chemiluminescence imaging of ignition through a shock tube end-wall

    NASA Astrophysics Data System (ADS)

    Troutman, V. A.; Strand, C. L.; Campbell, M. F.; Tulgestke, A. M.; Miller, V. A.; Davidson, D. F.; Hanson, R. K.

    2016-03-01

    A high-speed OH* chemiluminescence imaging diagnostic was developed to image the structure and homogeneity of combustion events behind reflected shock waves in the Stanford Constrained Reaction Volume Shock Tube. An intensified high-repetition-rate imaging system was used to acquire images of OH* chemiluminescence (near 308 nm) through a fused quartz shock tube end-wall window at 10-33 kHz during the combustion of n-heptane (21 % O2/Ar, φ = 0.5). In general, the imaging technique enabled observation of the main ignition event in the core of the shock tube that corresponded to typical markers of ignition (e.g., pressure rise), as well as localized ignition near the wall that preceded the main core ignition event for some conditions. Case studies were performed to illustrate the utility of this novel imaging diagnostic. First, by comparing localized wall ignition events to the core ignition event, the temperature homogeneity of the post-reflected shock gas near the end-wall was estimated to be within 0.5 % for the test condition presented (T=1159 hbox {K}, P=0.25 hbox {MPa}). Second, the effect of a recession in the shock tube wall, created by an observation window, on the combustion event was visualized. Localized ignition was observed near the window, but this disturbance did not propagate to the core of the shock tube before the main ignition event. Third, the effect of shock tube cleanliness was investigated by conducting tests in which the shock tube was not cleaned for multiple consecutive runs. For tests after no cleaning was performed, ignition events were concentrated in the lower half of the shock tube. In contrast, when the shock tube was cleaned, the ignition event was distributed around the entire circumference of the shock tube; validating the cleaning procedure.

  15. Measurements of carbon monoxide and nitrogen dioxide in British homes using unflued heating or cooking appliances.

    PubMed

    Stevenson, K J

    1985-08-01

    Measurements of Carbon Monoxide (CO) and Nitrogen Dioxide (NO2) were made in three kitchens, two with gas cookers and one all electric, and two living rooms, one heated by a portable butane heater and the other by a paraffin stove. The measurements were taken whilst the homes were in normal use and the occupants kept a diary of when specific appliances were used. Measurements of NO2 were made simultaneously by chemiluminescence and by diffusion tubes. The accuracy of the diffusion tube measurements relative to the chemiluminescent standard was estimated as +/- 10% and the precision less than or equal to 300 ppb. hr. Results from diffusion tubes were used to indicate the distribution of NO2 throughout other rooms in the house. At the all electric house the CO and NO2 concentrations were very similar to the expected outdoor levels. In all the other houses NO2 levels exceeded typical outdoor concentrations measured in Central London and in the paraffin heated house and one gas cooking house median CO concentrations exceeded these measured at the curbside of a very busy road in Central London. The living room concentrations of NO2 where the paraffin heater was in use were elevated for long periods. Analysis of the decay of pollutant concentration in one kitchen yielded an effective deposition velocity for NO2 of 3 X 10(-5) m s-1. The magnitude of the CO and NO2 concentrations measured in this survey confirms that indoor air pollution should be taken into account when assessing overall public exposure to air pollution.

  16. [A study on europium sensitized chemiluminescence of pipemidic acid].

    PubMed

    Li, Xia; Qiang, Hong; Wang, Xiao-li; Chen, Shi-lü; Zhao, Hui-chun

    2004-12-01

    A flow injection chemiluminescence method for the determination of Pipemidic acid (PPA) was developed. It is based on luminescence produced with KMnO4-Na2S2O4 CL system sensitized by Eu3+-PPA. The familar excipients such as starch and dextrine do not cause interference. The several kinds of affect on chemiluminescence were studied. The linear range and detection limit for PPA are 7.00 x 10(-9)-9.00 x 10(-7) mol x L(-1) and 4.09 x 10(-9) mol x L(-1), respectively. This method have successfully been applied to the determination of PPA in tablet and urine. And the mechanism of chemiluminescence is proposed.

  17. Improvements in a chemiluminescent ozone analyzer for respiratory applications

    NASA Astrophysics Data System (ADS)

    Ben-Jebria, Abdellaziz; Hu, Shu-Chieh; Ultman, James S.

    1990-11-01

    The performance characteristics of a previously developed analyzer utilizing the homogeneous chemiluminescent reaction of ozone (O3) with a stoichiometric excess of 2-methyl-2-butene were improved with the eventual goal of measuring the distribution of O3 in a single human breath. By increasing the sampling flow from 200 to 400 ml/min and utilizing a combination of analog and digital filtering, it was possible to improve the signal-to-noise ratio at 0.5 ppm O3 from 5.5 to 28, the minimum detection limit from 0.02 to 0.01 ppm, the sensitivity from 1.5 to 2.3 na/ppm, and the 10%-90% step-response time from 200 to 100 ms. Humidity, temperature, and inlet gas composition interferences were also evaluated. While temperature and humidity have no influence on the analyzer output, the substitution of carbon dioxide for oxygen increased the analyzer sensitivity by 3.8% for each percent of CO2 that was present. Thus, provided that an appropriate correction for carbon dioxide is made, these improvements allow the instrument to monitor inhaled and exhaled O3 concentrations with a rapid dynamic response and over a broad range of physiologically relevant values.

  18. A readout circuit dedicated for the detection of chemiluminescence using a silicon photomultiplier

    NASA Astrophysics Data System (ADS)

    Baszczyk, M.; Dorosz, P.; Mik, L.; Kucewicz, W.; Reczynski, W.; Sapor, M.

    2018-05-01

    A readout circuit dedicated for the detection of the chemiluminescence phenomenon using a silicon photomultiplier (SiPM) is presented. During chemiluminescence, light is generated as a result of chemical reaction. Chemiluminescence is used in many applications within medicine, chemistry, biology and biotechnology, and is one of the most important sensing techniques in biomedical science and clinical medicine. The front-end electronics consist of a preamplifier and a fast shaper—this produces pulses, the peaking time which is 3.6 ns for a single photon and the FWHM is 3.8 ns. The system has been optimised to measure chemiluminescence—it is sensitive at the level of single photons, it generates a low number of overlapping pulses and is accurate. Two methods of signal detection are analysed and compared: the counting of events and amplitude detection. The relationship between the chemiluminescence light intensity and the concentration of the chemical compound (luminol) is linear in the range of the tested concentrations and has strong linearity parameters and low prediction intervals.

  19. Graphene-based chemiluminescence resonance energy transfer for homogeneous immunoassay.

    PubMed

    Lee, Joon Seok; Joung, Hyou-Arm; Kim, Min-Gon; Park, Chan Beum

    2012-04-24

    We report on chemiluminescence resonance energy transfer (CRET) between graphene nanosheets and chemiluminescent donors. In contrast to fluorescence resonance energy transfer, CRET occurs via nonradiative dipole-dipole transfer of energy from a chemiluminescent donor to a suitable acceptor molecule without an external excitation source. We designed a graphene-based CRET platform for homogeneous immunoassay of C-reactive protein (CRP), a key marker for human inflammation and cardiovascular diseases, using a luminol/hydrogen peroxide chemiluminescence (CL) reaction catalyzed by horseradish peroxidase. According to our results, anti-CRP antibody conjugated to graphene nanosheets enabled the capture of CRP at the concentration above 1.6 ng mL(-1). In the CRET platform, graphene played a key role as an energy acceptor, which was more efficient than graphene oxide, while luminol served as a donor to graphene, triggering the CRET phenomenon between luminol and graphene. The graphene-based CRET platform was successfully applied to the detection of CRP in human serum samples in the range observed during acute inflammatory stress.

  20. A turn-on chemiluminescence biosensor for selective and sensitive detection of adenosine based on HKUST-1 and QDs-luminol-aptamer conjugates.

    PubMed

    Lin, Yanna; Dai, Yuxue; Sun, Yuanling; Ding, Chaofan; Sun, Weiyan; Zhu, Xiaodong; Liu, Hao; Luo, Chuannan

    2018-05-15

    In this work, HKUST-1 and QDs-luminol-aptamer conjugates were prepared. The QDs-luminol-aptamer conjugates can be adsorbed by graphene oxide through π-π conjugation. When the adenosine was added, the QDs-luminol-aptamer conjugates were released from magnetic graphene oxide (MGO), the chemiluminescent switch was turned on. It was reported that HKUST-1 can catalyze the chemiluminescence reaction of luminol-H 2 O 2 system in an alkaline medium, and improve the chemiluminescence resonance energy transfer (CRET) between chemiluminescence and QDs indirectly. Thus, the adenosine can be detected sensitively. Based on this phenomenon, the excellent platform for detection of adenosine was established. Under the optimized conditions, the linear detection range for adenosine was 1.0 × 10 -12 -2.2 × 10 -10 mol/L with a detection limit of 2.1 × 10 -13 mol/L. The proposed method was successfully used for adenosine detection in biological samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Chemiluminescence: An Illuminating Experiment

    ERIC Educational Resources Information Center

    Gafney, Harry D.; Adamson, Arthur W.

    1975-01-01

    Describes an experiment in which luminescence is observed during a reaction between sodium borohydride and trisbipyridalruthenium (III). Includes a discussion of the theory of chemiluminescence. (MLH)

  2. Increased resistance to oxidative stress in normal and glucose-6-phosphate dehydrogenase-deficient hemolysates in the presence of enzyme substrates.

    PubMed

    Yücel, G; Yeşilkaya, A; Aksu, T A; Yeğin, A; Alicigüzel, Y

    1997-01-01

    Erythrocytes and hemolysates from 10 normal and 10 glucose-6-phosphate dehydrogenase-deficient individuals were incubated with cumene hydroperoxide, and free radical-induced lipid peroxidation was monitored by chemiluminescence. Chemiluminescence intensities in erythrocytes of normal and deficient subjects were similar in the presence or absence of glucose-6-phosphate dehydrogenase substrates. Hemolysates of normal and deficient subjects also showed similar chemiluminescence in the absence of substrates. However, with the addition of substrates to the incubation medium, deficient hemolysates reached maximum chemiluminescence intensity within a shorter period, and maximum values were higher than in normal hemolysates. We believe this offers a new means of detection of glucose-6-phosphate dehydrogenase-deficient patients.

  3. Chemiluminescence determination of terbutaline sulfate in bovine urine and pharmaceutical preparations based on enhancement of the 2-phenyl-4, 5-di (2-furyl) imidazole-potassium ferricyanide system.

    PubMed

    Han, Lu; Zhang, Yumin; Kang, Jing; Tang, Jieli; Zhang, Yihua

    2012-01-25

    In this paper, a novel chemiluminescence (CL) system, 2-phenyl-4, 5-di (2-furyl) imidazole (PDFI)-potassium ferricyanide, for the determination of terbutaline sulfate was described. The method was based on enhancement of CL emission of PDFI-potassium ferricyanide system in the presence of terbutaline sulfate. Under the optimum conditions, the enhanced chemiluminescence intensity is linearly related to the concentration of terbutaline sulfate. The proposed method has been successfully applied to the determination of terbutaline sulfate in bovine urine and pharmaceutical preparations with satisfactory results. Furthermore, the possible mechanism of chemiluminescence reaction was also discussed briefly. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Structural aspects of coaxial oxy-fuel flames

    NASA Astrophysics Data System (ADS)

    Ditaranto, M.; Sautet, J. C.; Samaniego, J. M.

    Oxy-fuel combustion has been proven to increase thermal efficiency and to have a potential for NOx emission reduction. The study of 25-kW turbulent diffusion flames of natural gas with pure oxygen is undertaken on a coaxial burner with quarl. The structural properties are analysed by imaging the instantaneous reaction zone by OH* chemiluminescence and measuring scalar and velocity profiles. The interaction between the flame front and the shear layers present in the coaxial jets depends on the momentum ratio which dictates the turbulent structure development. Flame length and NOx emission sensitivity to air leaks in the combustion chamber are also investigated.

  5. Performance of an exhaled nitric oxide and carbon dioxide sensor using quantum cascade laser-based integrated cavity output spectroscopy.

    PubMed

    McCurdy, Matthew R; Bakhirkin, Yury; Wysocki, Gerard; Tittel, Frank K

    2007-01-01

    Exhaled nitric oxide (NO) is an important biomarker in asthma and other respiratory disorders. The optical performance of a NOCO(2) sensor employing integrated cavity output spectroscopy (ICOS) with a quantum cascade laser operating at 5.22 microm capable of real-time NO and CO(2) measurements in a single breath cycle is reported. A NO noise-equivalent concentration of 0.4 ppb within a 1-sec integration time is achieved. The off-axis ICOS sensor performance is compared to a chemiluminescent NO analyzer and a nondispersive infrared (NDIR) CO(2) absorption capnograph. Differences between the gas analyzers are assessed by the Bland-Altman method to estimate the expected variability between the gas sensors. The off-axis ICOS sensor measurements are in good agreement with the data acquired with the two commercial gas analyzers. This work demonstrates the performance characteristics and merits of mid-infrared spectroscopy for exhaled breath analysis.

  6. Method for measuring pollutant formation

    NASA Technical Reports Server (NTRS)

    Stickler, David B. (Inventor); Annen, Kurt (Inventor)

    2001-01-01

    Diagnostic methods for determining an instantaneous rate of pollutant formation in a combustion system are based on measurement of chemiluminescence intensity generated simultaneously with the formation of the pollutant. The chemiluminescent signal is generated by an analog reaction which occurs in parallel with a key step in the formation of a specific pollutant of interest. The connection between the analog reaction and the pollution reaction is such that the chemiluminescent signal indicates the local, instantaneous formation rate of the pollutant of interest.

  7. Determination of total sulfur content via sulfur-specific chemiluminescence detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kubala, S.W.; Campbell, D.N.; DiSanzo, F.P.

    A specially designed system, based upon sulfur-specific chemiluminescence detection (SSCD), was developed to permit the determination of total sulfur content in a variety of samples. This type of detection system possesses several advantages such as excellent linearity and selectivity, low minimum detectable levels, and an equimolar response to various sulfur compounds. This paper will focus on the design and application of a sulfur-specific chemiluminescence detection system for use in determining total sulfur content in gasoline.

  8. Chemiluminescence of Organic Compounds.

    DTIC Science & Technology

    1981-04-07

    of organic reaction chemiluminescence (Rauiht, 197) ; Hastings and Wilson, 1976 ; Gundermann, 1974 ; White et al., 1974 ; McCapra, 1973 ; .oto, 1979...1977; Wilson, T., 1976; Turro et al., JI U4a; Mumtord, 1915), the chemiluminescence -4- of hydrazides (Roswell and White , 1978 ; White and Roswell...mechanical Iv exc, it cd . iii; q ie ed in a react inn, meaning energv is released in period ot t ime noi the *r?-!tcr of Ol I ess than thle t ime of a

  9. Efficient Generation of Chemiluminescence during the reduction of manganese(IV) ions with lactic acid

    NASA Astrophysics Data System (ADS)

    Tsaplev, Yu. B.

    2016-12-01

    The kinetics and mechanism of chemiluminescence during the reduction of manganese(IV) ions with lactic acid in an H2SO4-AcOH medium are studied. Kinetic spectrophotometric measurements are used to determine the profiles of change in the concentrations of Mn(IV) and Mn(III) ions during the reaction. The results from kinetic spectrophotometric measurements are compared to the light yield kinetics. The quantum chemiluminescence and chemiexcitation yields reach record values.

  10. Chemiluminescence behaviour of CdTe-potassium permanganate enhanced by sodium hexametaphosphate and sensitized sensing of L-ascorbic acid.

    PubMed

    Chen, Hongqi; Ling, Bo; Yuan, Fei; Zhou, Cailing; Chen, Jingguo; Wang, Lun

    2012-01-01

    A highly sensitive flow-injection chemiluminescence (FIA-CL) method based on the CdTe nanocrystals and potassium permanganate chemiluminescence system was developed for the determination of L-ascorbic acid. It was found that sodium hexametaphosphate (SP), as an enhancer, could increase the chemiluminescence (CL) emission from the redox reaction of CdTe quantum dots with potassium permanganate in near-neutral pH conditions. L-ascorbic acid is suggested as a sensitive enhancer for use in the above energy-transfer excitation process. Under optimal conditions, the calibration graph of emission intensity against logarithmic l-ascorbic acid concentration was linear in the range 1.0 × 10(-9)-5.0 × 10(-6)  mol/L, with a correlation coefficient of 0.9969 and relative standard deviation (RSD) of 2.3% (n = 7) at 5.0 × 10(-7)  mol/L. The method was successfully used to determine L-ascorbic acid in vitamin C tablets. The possible mechanism of the chemiluminescence in the system is also discussed. Copyright © 2012 John Wiley & Sons, Ltd.

  11. Flow-based analysis using microfluidics-chemiluminescence systems.

    PubMed

    Al Lawati, Haider A J

    2013-01-01

    This review will discuss various approaches and techniques in which analysis using microfluidics-chemiluminescence systems (MF-CL) has been reported. A variety of applications is examined, including environmental, pharmaceutical, biological, food and herbal analysis. Reported uses of CL reagents, sample introduction techniques, sample pretreatment methods, CL signal enhancement and detection systems are discussed. A hydrodynamic pumping system is predominately used for these applications. However, several reports are available in which electro-osmotic (EO) pumping has been implemented. Various sample pretreatment methods have been used, including liquid-liquid extraction, solid-phase extraction and molecularly imprinted polymers. A wide range of innovative techniques has been reported for CL signal enhancement. Most of these techniques are based on enhancement of the mixing process in the microfluidics channels, which leads to enhancement of the CL signal. However, other techniques are also reported, such as mirror reaction, liquid core waveguide, on-line pre-derivatization and the use of an opaque white chip with a thin transparent seal. Photodetectors are the most commonly used detectors; however, other detection systems have also been used, including integrated electrochemiluminescence (ECL) and organic photodiodes (OPDs). Copyright © 2012 John Wiley & Sons, Ltd.

  12. Eddy covariance fluxes of the NO-NO2-O3 triad above a spruce forest canopy in south-eastern Germany.

    NASA Astrophysics Data System (ADS)

    Tsokankunku, A.; Zhu, Z.; Meixner, F. X.; Foken, T.; Andreae, M. O.

    2009-04-01

    We investigated the diel variability of the eddy covariance fluxes of the NO-NO2-O3 triad above a spruce forest canopy at the "Weidenbrunnen" research site (Fichtelgebirge, Germany). Measurements were part of the EGER project (ExchanGE processes in mountainous Regions), which focuses on the role of process interactions among the different scales of soil, in-canopy and atmospheric exchange processes of reactive and non-reactive trace gases and energy. The eddy covariance platform was at the top of a 32 m high tower (50˚ 08'31" N, 11˚ 52'1"E, elevation 755 m.a.s.l). The eddy covariance system consisted of a CSAT3 sonic anemometer and a high speed, high resolution NO-NO2two channel chemiluminescence analyzer (Ecophysics CLD 790 SR2). A solid-state blue-light photolytic converter was connected to the NO2 channel of the analyzer just behind the sample inlet. Ambient NO and NO2 mixing ratios were sampled via 52 m long tubes with the instrument itself located in a temperature-controlled container at the ground. The NO-NO2 analyzer was operated at 5 Hz. Additionally we measured eddy covariance fluxes of CO2 and H2O. An infrared absorption-based analyzer (LI-7000) was used to sample CO2 and H2O mixing ratios, and a fast solid-phase chemiluminescence ozone analyzer (GFAS) was deployed to measure O3 mixing ratios. All trace gas inlets were situated at 32.5 m, 20 cm below the path of the sonic anemometer. The 32m inlet of an independent NO, NO2, and O3 concentration profile measuring system was used as the calibration source for the fast ozone analyzer and the two channel NO-NO2chemiluminescence analyzer. Preliminary results show that NO and NO2advection plays a big role in the magnitude and direction of the fluxes at the site. The main source of the advection is a busy country road situated about 2 km west of the site. CO2 fluxes were also influenced by advection. Extended periods of stationarity usually occurred on Sundays when the amount of traffic was significantly lower. During the "golden days period" (29 June - 3 July 2008), there was mainly downward directed NO fluxes (within the margin of error). However there is also evidence of NO leaving the canopy in some instances. NO and NO2 fluxes ranged between +1.5 and -1.5 nmol m-2 s-1 (±45 ngNO m-2 s-1 and ±70 ngNO2 m-2 s-1).

  13. Chemiluminescent prediction of service life

    NASA Technical Reports Server (NTRS)

    Hassell, J. A.; Mendenhall, G. D.; Nathan, R. A.

    1976-01-01

    Technique can be used to predict polymer degradation under actual expected-use conditions, without imposing artificial conditions. Smooth or linear correlations are obtained between chemiluminescence and physical properties of purified polymer gums.

  14. EphB1 as a Novel Drug Target to Combat Pain and Addiction

    DTIC Science & Technology

    2016-09-01

    goals? Strong progress has been made since we changed directions. We have developed a very robust AlphaScreen chemiluminescent assay that probes the...hit compounds, 22, that reduced the chemiluminescent signal >10% at a concentration of 5 uM compound, with 6 of these compounds reducing over 25% (and...we have developed a very robust chemiluminescent Alpha assay that allows us to measure with a high degree of well- to-well consistency in 384 well

  15. Biological water quality monitoring using chemiluminescent and bioluminescent techniques

    NASA Technical Reports Server (NTRS)

    Thomas, R. R.

    1978-01-01

    Automated chemiluminescence and bioluminescence sensors were developed for the continuous monitoring of microbial levels in water supplies. The optimal chemical procedures were determined for the chemiluminescence system to achieve maximum sensitivity. By using hydrogen peroxide, reaction rate differentiation, ethylene diamine tetraacetic acid (EDTA), and carbon monoxide pretreatments, factors which cause interference were eliminated and specificity of the reaction for living and dead bacteria was greatly increased. By employing existing technology with some modifications, a sensitive and specific bioluminescent system was developed.

  16. Analytical Applications of Bioluminescence and Chemiluminescence

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W. (Editor); Picciolo, G. L. (Editor)

    1975-01-01

    Bioluminescence and chemiluminescence studies were used to measure the amount of adenosine triphosphate and therefore the amount of energy available. Firefly luciferase - luciferin enzyme system was emphasized. Photometer designs are also considered.

  17. Quantification of drugs in plasma without primary reference standards by liquid chromatography-chemiluminescence nitrogen detection: application to tramadol metabolite ratios.

    PubMed

    Ojanperä, Suvi; Rasanen, Ilpo; Sistonen, Johanna; Pelander, Anna; Vuori, Erkki; Ojanperä, Ilkka

    2007-08-01

    Lack of availability of reference standards for drug metabolites, newly released drugs, and illicit drugs hinders the analysis of these substances in biologic samples. To counter this problem, an approach is presented here for quantitative drug analysis in plasma without primary reference standards by liquid chromatography-chemiluminescence nitrogen detection (LC-CLND). To demonstrate the feasibility of the method, metabolic ratios of the opioid drug tramadol were determined in the setting of a pharmacogenetic study. Four volunteers were given a single 100-mg oral dose of tramadol, and a blood sample was collected from each subject 1 hour later. Tramadol, O-desmethyltramadol, and nortramadol were determined in plasma by LC-CLND without reference standards and by a gas chromatography-mass spectrometry reference method. In contrast to previous CLND studies lacking an extraction step, a liquid-liquid extraction system was created for 5-mL plasma samples using n-butyl chloride-isopropyl alcohol (98 + 2) at pH 10. Extraction recovery estimation was based on model compounds chosen according to their similar physicochemical characteristics (retention time, pKa, logD). Instrument calibration was performed with a single secondary standard (caffeine) using the equimolar response of the detector to nitrogen. The mean differences between the results of the LC-CLND and gas chromatography-mass spectrometry methods for tramadol, O-desmethyltramadol, and nortramadol were 8%, 32%, and 19%, respectively. The sensitivity of LC-CLND was sufficient for therapeutic concentrations of tramadol and metabolites. A good correlation was obtained between genotype, expressed by the number of functional genes, and the plasma metabolite ratios. This experiment suggests that a recovery-corrected LC-CLND analysis produces sufficiently accurate results to be useful in a clinical context, particularly in instances in which reference standards are not readily accessible.

  18. Chemiluminescence and bioluminescence microbe detection

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Chappelle, E.; Picciolo, G. L.; Jeffers, E. L.; Thomas, R. R.

    1978-01-01

    Automated biosensors for online use with NASA Water Monitoring System employs bioluminescence and chemiluminescence techniques to rapidly measure microbe contamination of water samples. System eliminates standard laboratory procedures requiring time duration of 24 hours or longer.

  19. Analysis of street drugs in seized material without primary reference standards.

    PubMed

    Laks, Suvi; Pelander, Anna; Vuori, Erkki; Ali-Tolppa, Elisa; Sippola, Erkki; Ojanperä, Ilkka

    2004-12-15

    A novel approach was used to analyze street drugs in seized material without primary reference standards. Identification was performed by liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS), essentially based on accurate mass determination using a target library of 735 exact monoisotopic masses. Quantification was carried out by liquid chromatography/chemiluminescence nitrogen detection (LC/CLND) with a single secondary standard (caffeine), utilizing the detector's equimolar response to nitrogen. Sample preparation comprised dilution, first with methanol and further with the LC mobile phase. Altogether 21 seized drug samples were analyzed blind by the present method, and results were compared to accredited reference methods utilizing identification by gas chromatography/mass spectrometry and quantification by gas chromatography or liquid chromatography. The 31 drug findings by LC/TOFMS comprised 19 different drugs-of-abuse, byproducts, and adulterants, including amphetamine and tryptamine designer drugs, with one unresolved pair of compounds having an identical mass. By the reference methods, 27 findings could be confirmed, and among the four unconfirmed findings, only 1 apparent false positive was found. In the quantitative analysis of 11 amphetamine, heroin, and cocaine findings, mean relative difference between the results of LC/CLND and the reference methods was 11% (range 4.2-21%), without any observable bias. Mean relative standard deviation for three parallel LC/CLND results was 6%. Results suggest that the present combination of LC/TOFMS and LC/CLND offers a simple solution for the analysis of scheduled and designer drugs in seized material, independent of the availability of primary reference standards.

  20. Laser-saturated fluorescence of nitric oxide and chemiluminescence measurements in premixed ethanol flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marques, Carla S.T.; Barreta, Luiz G.; Sbampato, Maria E.

    In this study, nitric oxide laser-saturated fluorescence (LSF) measurements were acquired from premixed ethanol flames at atmospheric pressure in a burner. NO-LSF experimental profiles for fuel-rich premixed ethanol flames ({phi} = 1.34 and {phi} = 1.66) were determined through the excitation/detection scheme of the Q{sub 2}(26.5) rotational line in the A{sup 2}{sigma}{sup +} - X{sup 2}{pi} (0,0) vibronic band and {gamma}(0,1) emission band. A calibration procedure by NO doping into the flame was applied to establish the NO concentration profiles in these flames. Chemiluminescent emission measurements in the (0, 0) vibronic emission bands of the OH{sup *} (A{sup 2}{sigma}{sup +}more » - X{sup 2}{pi}) and CH{sup *}(A{sup 2}{delta} - X{sup 2}{pi}) radicals were also obtained with high spatial and spectral resolution for fuel-rich premixed ethanol flames to correlate them with NO concentrations. Experimental chemiluminescence profiles and the ratios of the integrated areas under emission spectra (A{sub CH*}/A{sub CH*}(max.) and A{sub CH*}/A{sub OH*}) were determined. The relationships between chemiluminescence and NO concentrations were established along the premixed ethanol flames. There was a strong connection between CH{sup *} radical chemiluminescence and NO formation and the prompt-NO was identified as the governing mechanism for NO production. The results suggest the optimum ratio of the chemiluminescence of two radicals (A{sub CH*}/A{sub OH*}) for NO diagnostic purposes. (author)« less

  1. Gold nanoparticles based chemiluminescent resonance energy transfer for immunoassay of alpha fetoprotein cancer marker.

    PubMed

    Huang, Xiangyi; Ren, Jicun

    2011-02-07

    In this paper, we report a new strategy of chemiluminescence resonance energy transfer (CRET) by using gold nanoparticles (AuNPs) as efficient long-range energy acceptor in sandwich immunoassays. In the design of CRET system, we chose the highly sensitive chemiluminescence (CL) reaction of luminol and hydrogen peroxide catalysed by horseradish peroxidase (HRP) because the CL spectrum of luminol (λ(max) 425 nm) partially overlaps with the visible absorption bands of AuNPs. On the basis of CRET strategy, we developed a sandwich immunoassay of alpha fetoprotein (AFP) cancer marker. In immunoassay, two antibodies (anti-AFP-1 and anti-AFP-2) were conjugated to AuNPs and horseradish peroxidase (HRP), respectively. The sandwich-type immunoreactions between the AFP (antigen) and the two different antibodies bridged the donors (luminol) and acceptors (AuNPs), which led to the occurrence of CRET from luminol to AuNPs upon chemiluminescent reaction. We observed that the quenching of chemiluminescence signal depended linearly on the AFP concentration within a range of concentration from 5 to 70 ng mL(-1) and the detection limit of AFP was 2.5 ng mL(-1). Our method was successfully applied for determination of AFP levels in sera from cancer patients, and the results were in good agreement with ELISA assays. This approach is expected to be extended to other assay designs, that is, using other antibodies, analytes, chemiluminescent substance, and even other metallic nanoparticles. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Kinetics and selectivity of permanganate chemiluminescence: a study of hydroxyl and amino disubstituted benzene positional isomers.

    PubMed

    Slezak, Teo; Smith, Zoe M; Adcock, Jacqui L; Hindson, Christopher M; Barnett, Neil W; Nesterenko, Pavel N; Francis, Paul S

    2011-11-30

    Examination of the chemiluminescence reactions of dihydroxybenzenes, aminophenols and phenylenediamines with acidic potassium permanganate has provided a new understanding of the relationships between analyte structure, reaction conditions, kinetics of the light-producing pathway and emission intensity, with broad implications for this widely utilised chemiluminescence detection system. Using a permanganate reagent prepared in a polyphosphate solution and adjusted to pH 2.5, large differences in the rate of reaction with different positional isomers were observed, with the meta-substituted forms reacting far slower and therefore exhibiting much lower chemiluminescence intensities in flow analysis systems. The preliminary partial reduction of permanganate to form significant concentrations of Mn(III) increased the rate of reaction with all analytes tested, resulting in comparable or (in the case of aminophenol and phenylenediamine) even greater emission intensities for the meta-isomers, demonstrating the opportunity to tune the selectivity of the reagent towards certain classes of compound or even specific positional isomers of the same compound. Using more acidic permanganate reagents, in which polyphosphates are not required, the discrepancy between the chemiluminescence intensities was still observed, but was less prominent due to the generally faster rates of reaction. The enhancement of these chemiluminescence reactions by on-line addition of formic acid or formaldehyde can in part also be attributed to the generation of significant pools of the key Mn(III) precursor to the emitting species. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Optical Communication among Oscillatory Reactions and Photo-Excitable Systems: UV and Visible Radiation Can Synchronize Artificial Neuron Models.

    PubMed

    Gentili, Pier Luigi; Giubila, Maria Sole; Germani, Raimondo; Romani, Aldo; Nicoziani, Andrea; Spalletti, Anna; Heron, B Mark

    2017-06-19

    Neuromorphic engineering promises to have a revolutionary impact in our societies. A strategy to develop artificial neurons (ANs) is to use oscillatory and excitable chemical systems. Herein, we use UV and visible radiation as both excitatory and inhibitory signals for the communication among oscillatory reactions, such as the Belousov-Zhabotinsky and the chemiluminescent Orban transformations, and photo-excitable photochromic and fluorescent species. We present the experimental results and the simulations regarding pairs of ANs communicating by either one or two optical signals, and triads of ANs arranged in both feed-forward and recurrent networks. We find that the ANs, powered chemically and/or by the energy of electromagnetic radiation, can give rise to the emergent properties of in-phase, out-of-phase, anti-phase synchronizations and phase-locking, dynamically mimicking the communication among real neurons. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Chemiluminescence of Acanthamoeba castellanii.

    PubMed Central

    Lloyd, D; Boveris, A; Reiter, R; Filipkowski, M; Chance, B

    1979-01-01

    1. Chemiluminescence of Acanthomoeba castellanii in the presence of O2 was of similar intensity in organisms harvested early or late during exponential growth [when cyanide (1 mM) stimulates or inhibits respiration respectively]. 2. Cyanide (up to 1.5 mM) stimulated photoemission in both types of organism by 250--300 photons/s per 10(7) cells above the value observed under aerobic conditions. 3. 'Dibromothymoquinone' (2,5-dibromo-6-isopropyl-3-methyl-p-benzoquinone) (up to 80 microM) further increased chemiluminescence. 4. Similar responses were also demonstrated in whole homogenates and in subcellular fractions; 36% of the chemiluminescence was provided by a fraction sedimenting at 100000g-min, and 20% in that fraction that was non-sedimentable at 200000g-min. 5. Mitochondrial substrates (succinate, 2-oxoglutarate, NADH) in the presence or absence of ADP and Pi or peroxisomal substrates (glycollate, urate or ethanol) gave no increases in light emission by whole homogenates or in any of the fractions. 6. It is suggested that reactions responsible for production of chemiluminescence are those primarily producing superoxide anions and leading to lipid peroxidation and singlet-oxygen formation. Photoemission enhancement and superoxide dismutase inhibition showed similar cyanide concentration-dependencies. PMID:534514

  5. Activation of normal neutrophils by anti-neutrophil cytoplasm antibodies.

    PubMed Central

    Keogan, M T; Esnault, V L; Green, A J; Lockwood, C M; Brown, D L

    1992-01-01

    Anti-neutrophil cytoplasm antibodies (ANCA) are markers of systemic vasculitis for which a pathogenetic role has been postulated. We have examined the effect of these autoantibodies on the function of normal human neutrophils in vitro. In the presence of ANCA positive sera luminol-amplified chemiluminescence was significantly increased compared to the values seen in the presence of normal or anti-double stranded DNA positive sera (P < 0.01). Five of six ANCA positive F(ab)2 preparations also produced significant neutrophil activation as demonstrated by the chemiluminescence response. This response was totally abrogated by the addition of neutrophil cytoplasm extract, containing the ANCA antigen. Addition of inhibitors to the chemiluminescence system demonstrated that the chemiluminescence response was inhibited by azide and salicylhydroxamic acid and reduced by histidine, suggesting that the chemiluminescence response was due to activation of myeloperoxidase, with generation of singlet oxygen. The chemotactic response to f-Met-Leu-Phe, a bacterial chemotactic peptide, was significantly augmented in the presence of ANCA. Chemotaxis to zymosan-activated serum and chemokinesis was not affected. Phagocytosis was also unaffected. We propose that neutrophil activation and modulation of neutrophil migration by ANCA may be of pathogenetic significance in systemic vasculitis. PMID:1424279

  6. Gold nanorods-enhanced rhodamine B-permanganate chemiluminescence and its analytical application.

    PubMed

    Hassanzadeh, Javad; Amjadi, Mohammad; Manzoori, Jamshid L; Sorouraddin, Mohammad Hossein

    2013-04-15

    A novel enhanced chemiluminescence system was developed by applying gold nanorods (Au NRs) as catalysts in rhodamine B-permanganate reaction. Au NRs with three different aspect ratios were synthesized by seed mediated growth method and characterized by UV-Vis spectra and transmission electron microscopy. It was demonstrated that Au NRs have much higher catalytic effect than spherical nanoparticles on rhodamine B-permanganate chemiluminescence reaction. Among various sizes of Au NRs, those with average aspect ratio of 3.0 were found to have the most remarkable catalytic activity. As an analytical application of the new chemiluminescence system, albumin as a model protein was quantified based on its interaction with NRs. Albumin binds to Au NRs active surfaces and inhibits their catalytic action and therefore decreases the intensity of chemiluminescence. This diminution effect is linearly related to the concentration of the human and bovine serum albumin over the ranges of 0.45-90 and 0.75-123 nmol L(-1), respectively with the corresponding limits of detection of 0.18 and 0.30 nmol L(-1). The method was successfully applied to the determination of albumin in human and bovine serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Nonenzymatic chemiluminescent detection and quantitation of total protein on Western and slot blots allowing subsequent immunodetection and sequencing.

    PubMed

    Alba, F J; Daban, J R

    1997-10-01

    We have studied the light emission efficiency of proteins labeled with different fluorescent dyes chemically excited by the bis(2,4,6-trichlorophenyl)oxalate (TCPO)-H2O2 reaction. Using this peroxyoxalate chemiluminescence system, the best results were obtained with proteins covalently labeled with 2-methoxy-2,4-diphenyl-3(2H)-furanone (MDPF). Blotted proteins on polyvinylidene difluoride (PVDF) membranes can be labeled rapidly with MDPF. Our results demonstrate that energy from the excited intermediate produced in the TCPO-H2O2 reaction can be efficiently transferred to MDPF-labeled proteins in solution and on PVDF membranes. Although this nonenzymatic chemiluminescent system produces a background emission that reduces the sensitivity, the method developed in this work allows detection of 5 ng of protein in blots after 5 min exposure to X-ray film. Chemiluminescence of MDPF-labeled proteins on Western and slot blots may also be detected and quantified using a charge-coupled device (CCD) camera or a storage phosphor imaging system. This chemiluminescent method allows the staining of the total electrophoretic pattern but does not preclude further N-terminal sequencing and immunodetection of specific bands.

  8. Shock tubes and waves; Proceedings of the Thirteenth International Symposium, Niagara Falls, NY, July 6-9, 1981

    NASA Astrophysics Data System (ADS)

    Treanor, C. E.; Hall, J. G.

    1982-10-01

    The present conference on shock tubes and waves considers shock tube drivers, luminous shock tubes, shock tube temperature and pressure measurement, shock front distortion in real gases, nonlinear standing waves, transonic flow shock wave turbulent boundary interactions, wall roughness effects on reflected shock bifurcation, argon thermal conductivity, pattern generation in gaseous detonations, cylindrical resonators, shock tunnel-produced high gain lasers, fluid dynamic aspects of laser-metal interaction, and the ionization of argon gas behind reflected shock waves. Also discussed are the ionization relaxation of shock-heated plasmas and gases, discharge flow/shock tube studies of singlet oxygen, rotational and vibrational relaxation, chemiluminescence thermal and shock wave decomposition of hydrogen cyanide and hydrogen azide, shock wave structure in gas-particle mixtures at low Mach numbers, binary nucleation in a Ludwieg tube, shock liquefaction experiments, pipeline explosions, the shock wave ignition of pulverized coal, and shock-initiated methane combustion.

  9. Low-temperature interaction of U(IV) and XeO{sub 3} in frozen aqueous H{sub 2}SO{sub 4} solutions accompanied by chemiluminescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lotnik, S.V.; Khamidullina, L.A.; Kazakov, V.P.

    Low-temperature (T{ge}180K) oxidation of U(IV) by xenon trioxide accompanied by chemiluminescence is studied in a frozen 0.2 M H{sub 2}SO{sub 4} solution. It is shown that the peak of luminescence at 195-200 K is related to chemiluminescence of the excited uranyl ion (UO{sup 2+}{sub 2}) formed in the oxidation of U(V), an intermediate product of the interaction of U(IV) and XeO{sub 3}.

  10. Research and development of a luminol-carbon monoxide flow system

    NASA Technical Reports Server (NTRS)

    Thomas, R. R.

    1977-01-01

    Adaption of the luminol-carbon monoxide injection system to a flowing type system is reported. Analysis of actual wastewater samples was carried out and revealed that bacteria can be associated with particles greater than 10 microns in size in samples such as mixed liquor. Research into the luminol reactive oxidation state indicates that oxidized iron porphyrins, cytochrome-c in particular, produce more luminol chemiluminescence than the reduced form. Correlation exists between the extent of porphyrin oxidation and relative chemiluminescence. In addition, the porphyrin nucleus is apparently destroyed under the current chemiluminescent reaction conditions.

  11. Ozone measurements

    NASA Technical Reports Server (NTRS)

    Randhawa, J.

    1978-01-01

    The chemiluminescent ozonesonde to be flown with the STRATCOM balloon flight consisted of two main parts: (1) A constant-volume sampling pump made from TEFLON was used for the intake of the air sample. Sample was drawn at a rate of 200 millimeters per minute. (2) Ozone was detected by the chemiluminescent process (Rhodamine - B). Ozone molecules in the air sample flowed over the detector and the photons produced by the destruction of ozone molecules on the chemiluminescent material were monitored by the photomultiplier tube, the output signal from which was transmitted to the ground receiver.

  12. A flow injection chemiluminescence system for the determination of isoniazid.

    PubMed

    Huang, Y; Zhang, Z; Zhang, D; Lv, J

    2000-10-01

    A chemiluminescence (CL) flow system is described for the determination of isoniazid based on its enhancement on the chemiluminescence (CL) emission produced upon mixing a hexacyanoferrate(III) solution with an alkaline luminol solution. The system responds linearly to isoniazid concentration in the range 0-1 mg/L with a detection limit (3sigma) of 0.03 microg/L, relative standard deviation (RSD) of 1.2% for 0.1 mg/L isoniazid (n = 11). The system has been successfully applied to the determination of isoniazid in pharmaceutical preparations.

  13. A Facile and Effective Chemiluminescence Demonstration Experiment

    ERIC Educational Resources Information Center

    Mohan, Arthur G.; Turro, Nicholas J.

    1974-01-01

    Describes a chemiluminescence system which can be used to demonstrate the effects of certain factors which affect the rate of reaction (temperature, concentration, catalysis, solvent, etc.), and to perform experiments relevant to the mechanism of the system. (SLH)

  14. Tested Demonstrations. A Chemiluminescence Demonstration - Oxalyl Chloride Oxidation.

    ERIC Educational Resources Information Center

    Gilber, George L., Ed.

    1979-01-01

    This inexpensive, effective chemiluminescence demonstration requires minimal preparation. It is based on the oxidation of oxalyl chloride by hydrogen peroxide in the presence of an appropriate fluorescent sensitizer. The reaction mechanism is not completely understood. (BB)

  15. Heat release and flame structure measurements of self-excited acoustically-driven premixed methane flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kopp-Vaughan, Kristin M.; Tuttle, Steven G.; Renfro, Michael W.

    An open-open organ pipe burner (Rijke tube) with a bluff-body ring was used to create a self-excited, acoustically-driven, premixed methane-air conical flame, with equivalence ratios ranging from 0.85 to 1.05. The feed tube velocities corresponded to Re = 1780-4450. Coupled oscillations in pressure, velocity, and heat release from the flame are naturally encouraged at resonant frequencies in the Rijke tube combustor. This coupling creates sustainable self-excited oscillations in flame front area and shape. The period of the oscillations occur at the resonant frequency of the combustion chamber when the flame is placed {proportional_to}1/4 of the distance from the bottom ofmore » the tube. In this investigation, the shape of these acoustically-driven flames is measured by employing both OH planar laser-induced fluorescence (PLIF) and chemiluminescence imaging and the images are correlated to simultaneously measured pressure in the combustor. Past research on acoustically perturbed flames has focused on qualitative flame area and heat release relationships under imposed velocity perturbations at imposed frequencies. This study reports quantitative empirical fits with respect to pressure or phase angle in a self-generated pressure oscillation. The OH-PLIF images were single temporal shots and the chemiluminescence images were phase averaged on chip, such that 15 exposures were used to create one image. Thus, both measurements were time resolved during the flame oscillation. Phase-resolved area and heat release variations throughout the pressure oscillation were computed. A relation between flame area and the phase angle before the pressure maximum was derived for all flames in order to quantitatively show that the Rayleigh criterion was satisfied in the combustor. Qualitative trends in oscillating flame area were found with respect to feed tube flow rates. A logarithmic relation was found between the RMS pressure and both the normalized average area and heat release rate for all flames. (author)« less

  16. [Development of selective determination methods for quinones with fluorescence and chemiluminescence detection and their application to environmental and biological samples].

    PubMed

    Kishikawa, Naoya

    2010-10-01

    Quinones are compounds that have various characteristics such as a biological electron transporter, an industrial product and a harmful environmental pollutant. Therefore, an effective determination method for quinones is required in many fields. This review describes the development of sensitive and selective determination methods for quinones based on some detection principles and their application to analyses in environmental, pharmaceutical and biological samples. Firstly, a fluorescence method was developed based on fluorogenic derivatization of quinones and applied to environmental analysis. Secondly, a luminol chemiluminescence method was developed based on generation of reactive oxygen species through the redox cycle of quinone and applied to pharmaceutical analysis. Thirdly, a photo-induced chemiluminescence method was developed based on formation of reactive oxygen species and fluorophore or chemiluminescence enhancer by the photoreaction of quinones and applied to biological and environmental analyses.

  17. Flow-injection chemiluminescence determination of melamine in urine and plasma.

    PubMed

    Tang, Xiaoshuang; Shi, Xiyan; Tang, Yuhai; Yue, Zhongjin; He, Qiqi

    2012-01-01

    A novel flow-injection chemiluminescence method for the determination of melamine in urine and plasma was developed. It was found that melamine can remarkably enhance chemiluminescence emission from the luminol-K(3) Fe(CN)(6) system in an alkaline medium. Under the optimum conditions, chemiluminescence intensity had a good linear relationship with the concentration of melamine in the range 9.0 × 10(-9) -7.0 × 10(-6) g/mL, with a correlation coefficient of 0.9992. The detection limit (3σ) was 3.5 ng/mL. The method has been applied to determine the concentration of melamine in samples using liquid-liquid extraction. Average recoveries of melamine were 102.6% in urine samples and 95.1% in plasma samples. The method provided a reproducible and stable approach for the sensitive detection of melamine in urine and plasma samples. Copyright © 2011 John Wiley & Sons, Ltd.

  18. A kinetic study of the enhancement of solution chemiluminescence of glyoxylic acid oxidation by manganese species.

    PubMed

    Otamonga, Jean-Paul; Abdel-Mageed, Amal; Agater, Irena B; Jewsbury, Roger A

    2015-08-01

    In order to study the mechanism of the enhancement of solution chemiluminescence, the kinetics of the decay of the oxidant and the chemiluminescence emission were followed for oxidations by permanganate, manganese dioxide sol and Mn(3+) (aq) of glyoxylic acid, using stopped-flow spectrophotometry. Results are reported for the glyoxylic acid oxidized under pseudo first-order conditions and in an acidic medium at 25 °C. For permanganate under these conditions, the decay is sigmoidal, consistent with autocatalysis, and for manganese dioxide sol and Mn(3+) it is pseudo first order. The effects of the presence of aqueous formaldehyde and Mn(2+) were observed and a fit to a simple mechanism is discussed. It is concluded that chemiluminescent enhancement in these systems is best explained by reaction kinetics. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Intrinsic Chemiluminescence Generation during Advanced Oxidation of Persistent Halogenated Aromatic Carcinogens.

    PubMed

    Mao, Li; Liu, Yu-Xiang; Huang, Chun-Hua; Gao, Hui-Ying; Kalyanaraman, Balaraman; Zhu, Ben-Zhan

    2015-07-07

    The ubiquitous distribution coupled with their carcinogenicity has raised public concerns on the potential risks to both human health and the ecosystem posed by the halogenated aromatic compounds (XAr). Recently, advanced oxidation processes (AOPs) have been increasingly favored as an "environmentally-green" technology for the remediation of such recalcitrant and highly toxic XAr. Here, we show that AOPs-mediated degradation of the priority pollutant pentachlorophenol and all other XAr produces an intrinsic chemiluminescence that directly depends on the generation of the extremely reactive hydroxyl radicals. We propose that the hydroxyl radical-dependent formation of quinoid intermediates and electronically excited carbonyl species is responsible for this unusual chemiluminescence production. A rapid, sensitive, simple, and effective chemiluminescence method was developed to quantify trace amounts of XAr and monitor their real-time degradation kinetics. These findings may have broad biological and environmental implications for future research on this important class of halogenated persistent organic pollutants.

  20. Chemiluminescence determination of ferulic acid by flow-injection analysis using cerium(IV) sensitized by rhodamine 6G.

    PubMed

    Wang, Ju Peng; Li, Nian Bing; Luo, Hong Qun

    2008-11-01

    A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with rhodamine 6G and ceric sulfate in sulphuric acid medium. Strong chemiluminescence signal was observed when ferulic acid was injected into the acidic ceric sulfate solution in a flow-cell. The present method allowed the determination of ferulic acid in the concentration range of 8.0 x 10(-6) to 1.0 x 10(-4) mol l(-1) and the detection limit for ferulic acid was 8.7 x 10(-9) mol l(-1). The relative standard deviation was 2.4% for 10 replicate analyses of 1.0 x 10(-5) mol l(-1) ferulic acid. The proposed method was applied to the determination of ferulic acid in Taita Beauty Essence samples with satisfactory results.

  1. Chemiluminescence determination of ferulic acid by flow-injection analysis using cerium(IV) sensitized by rhodamine 6G

    NASA Astrophysics Data System (ADS)

    Wang, Ju Peng; Li, Nian Bing; Luo, Hong Qun

    2008-11-01

    A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with rhodamine 6G and ceric sulfate in sulphuric acid medium. Strong chemiluminescence signal was observed when ferulic acid was injected into the acidic ceric sulfate solution in a flow-cell. The present method allowed the determination of ferulic acid in the concentration range of 8.0 × 10 -6 to 1.0 × 10 -4 mol l -1 and the detection limit for ferulic acid was 8.7 × 10 -9 mol l -1. The relative standard deviation was 2.4% for 10 replicate analyses of 1.0 × 10 -5 mol l -1 ferulic acid. The proposed method was applied to the determination of ferulic acid in Taita Beauty Essence samples with satisfactory results.

  2. A competitive chemiluminescence enzyme immunoassay for rapid and sensitive determination of enrofloxacin

    NASA Astrophysics Data System (ADS)

    Yu, Fei; Wu, Yongjun; Yu, Songcheng; Zhang, Huili; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B.

    With alkaline phosphatase (ALP)-adamantane (AMPPD) system as the chemiluminescence (CL) detection system, a highly sensitive, specific and simple competitive chemiluminescence enzyme immunoassay (CLEIA) was developed for the measurement of enrofloxacin (ENR). The physicochemical parameters, such as the chemiluminescent assay mediums, the dilution buffer of ENR-McAb, the volume of dilution buffer, the monoclonal antibody concentration, the incubation time, and other relevant variables of the immunoassay have been optimized. Under the optimal conditions, the detection linear range of 350-1000 pg/mL and the detection limit of 0.24 ng/mL were provided by the proposed method. The relative standard deviations were less than 15% for both intra and inter-assay precision. This method has been successfully applied to determine ENR in spiked samples with the recovery of 103%-96%. It showed that CLEIA was a good potential method in the analysis of residues of veterinary drugs after treatment of related diseases.

  3. Acetylsalicylic Acid Produces Different Effects on the Production of Active Oxygen Species by Activated Platelets in Different Inflammatory Diseases.

    PubMed

    Gabbasov, Z A; Kogan-Yasny, V V; Lakhno, D A; Kagan, L G; Ryzhkova, E V; Vasilieva, E Yu; Shpektor, A V

    2017-11-01

    We studied the effect of acetylsalicylic acid on ROS generation by platelets in patients after surgical interventions and in patients with bronchial asthma was studied. Platelets stimulated with platelet-activating factor are characterized by weak luminol-enhanced chemiluminescence in healthy people and patients after operations with laparoscopic incisions. Addition of platelet activation factor to platelet samples from patients after open abdominal surgery caused intensive chemiluminescence that was suppressed after platelet incubation with acetylsalicylic acid. At the same time, platelets of patients with aspirin-sensitive asthma did not respond to addition of platelet activating factor, but after incubation with acetylsalicylic acid, an intensive burst of chemiluminescence was detected with a maximum in 5-10 sec after the addition of a platelet-activating factor. In patients with bronchial asthma tolerant to aspirin, platelet activation factor did not induce chemiluminescence irrespective of incubation with acetylsalicylic acid.

  4. Investigation of singlet oxygen generation in Vit C-Cu2+ -LDL system by chemiluminescence method

    NASA Astrophysics Data System (ADS)

    Wang, Juan; Xing, Da; Tan, Shici; Tang, Yonghong; He, Yonghong

    2002-04-01

    In this study, by chemiluminescence method using a Cypridina luciferin analog, 2-methyl-6-(p-methoxyphenyl)-3,7- dihydroimidazo[1,2-a]pyrazin-3-one (MCLA), as a selective and sensitive chemiluminescence probe, singlet oxygen (1O2) formation was observed in the vit C- LDL-Cu2+ reaction system. Another experimental evidence for the generation of 1O2 was the quenching effect of sodium azide (NaN3) on vit C-induced chemiluminescence in the reaction mixture of LDL- Cu2+-MCLA. Analysis based on the experimental results indicated the plausible reaction mechanism is that vit C converts Cu2+ to its reduced state and vit C becomes vit C radical itself, thereby stimulating the formation of peroxyl radicals, and bimolecular reaction of peroxyl radicals results in 1O2 production in the above systems.

  5. Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection

    PubMed Central

    Heshka, Nicole E.; Hager, Darcy B.

    2015-01-01

    A method for the analysis of dissolved hydrogen sulfide in crude oil samples is demonstrated using gas chromatography. In order to effectively eliminate interferences, a two dimensional column configuration is used, with a Deans switch employed to transfer hydrogen sulfide from the first to the second column (heart-cutting). Liquid crude samples are first separated on a dimethylpolysiloxane column, and light gases are heart-cut and further separated on a bonded porous layer open tubular (PLOT) column that is able to separate hydrogen sulfide from other light sulfur species. Hydrogen sulfide is then detected with a sulfur chemiluminescence detector, adding an additional layer of selectivity. Following separation and detection of hydrogen sulfide, the system is backflushed to remove the high-boiling hydrocarbons present in the crude samples and to preserve chromatographic integrity. Dissolved hydrogen sulfide has been quantified in liquid samples from 1.1 to 500 ppm, demonstrating wide applicability to a range of samples. The method has also been successfully applied for the analysis of gas samples from crude oil headspace and process gas bags, with measurement from 0.7 to 9,700 ppm hydrogen sulfide. PMID:26709594

  6. Nitrogen dioxide (NO2) uptake by vegetation controlled by atmospheric concentrations and plant stomatal aperture

    NASA Astrophysics Data System (ADS)

    Chaparro-Suarez, I. G.; Meixner, F. X.; Kesselmeier, J.

    2011-10-01

    Nitrogen dioxide (NO2) exchange between the atmosphere and five European tree species was investigated in the laboratory using a dynamic branch enclosure system (consisting of two cuvettes) and a highly specific NO2 analyzer. NO2 measurements were performed with a sensitive gas phase chemiluminescence NO detector combined with a NO2 specific (photolytic) converter, both from Eco-Physics (Switzerland). This highly specific detection system excluded bias from other nitrogen compounds. Investigations were performed at two light intensities (Photosynthetic Active Radiation, PAR, 450 and 900 μmol m-2 s-1) and NO2 concentrations between 0 and 5 ppb. Ambient parameters (air temperature and relative humidity) were held constant. The data showed dominant NO2 uptake by the respective tree species under all conditions. The results did not confirm the existence of a compensation point within a 95% confidence level, though we cannot completely exclude emission of NO2 under very low atmospheric concentrations. Induced stomatal stricture, or total closure, by changing light conditions, as well as by application of the plant hormone ABA (Abscisic Acid) caused a corresponding decrease of NO2 uptake. No loss of NO2 to plant surfaces was observed under stomatal closure and species dependent differences in uptake rates could be clearly related to stomatal behavior.

  7. NASA 9-Point LDI Code Validation Experiment

    NASA Technical Reports Server (NTRS)

    Hicks, Yolanda R.; Anderson, Robert C.; Locke, Randy J.

    2007-01-01

    This presentation highlights the experimental work to date to obtain validation data using a 9-point lean direct injector (LDI) in support of the National Combustion Code. The LDI is designed to supply fuel lean, Jet-A and air directly into the combustor such that the liquid fuel atomizes and mixes rapidly to produce short flame zones and produce low levels of oxides of nitrogen and CO. We present NOx and CO emission results from gas sample data that support that aspect of the design concept. We describe this injector and show high speed movies of selected operating points. We present image-based species maps of OH, fuel, CH and NO obtained using planar laser induced fluorescence and chemiluminescence. We also present preliminary 2-component, axial and vertical, velocity vectors of the air flow obtained using particle image velocimetry and of the fuel drops in a combusting case. For the same combusting case, we show preliminary 3-component velocity vectors obtained using a phase Doppler anemometer. For the fueled, combusting cases especially, we found optical density is a technical concern that must be addressed, but that in general, these preliminary results are promising. All optical-based results confirm that this injector produces short flames, typically on the order of 5- to-7-mm long at typical cruise and high power engine cycle conditions.

  8. Chemiluminescence Study of the Autoxidation of cis-1,4-Polyisoprene

    NASA Technical Reports Server (NTRS)

    Mendenhall, G. David; Nathan, Richard A.; Golub, Morton A.

    1978-01-01

    The free-radical mechanism for the autoxidation of cis-1,4-polyisoprene (natural rubber or its synthetic counterpart) has been investigated extensively. An important feature of this mechanism, and indeed also of the autoxidation of hydrocarbons generally, is that it is a chain process propagated by alkyl and peroxy radicals and terminated through bimolecular reactions involving these same radicals. In the usual oxidation situation, that is, at all oxygen pressures greater than a few torr, the alkyl radicals are rapidly converted to peroxy radicals, and the termination step proceeds almost exclusively through the latter radicals. The bimolecular decay of the peroxy radicals is accompanied by a weak emission of light or chemiluminescence. Kinetic evidence is consistent with an electronically excited ketone produced in the termination reaction as the source of the emission. The first observation of chemiluminescence from the oxidative degradation of polymers was reported by Ashby, who dealt mainly with polypropylene but made passing mention of several other polymers. Subsequently, a number of papers have appeared dealing with oxidative chemiluminescence from a variety of polymers. In this paper we report the first detailed study of the chemiluminescence emitted in the autoxidation of cis-1,4-polyisoprene. The chemiluminescence technique is extremely sensitive and can follow rates of oxidation that are too slow to be measured conveniently by other means. This work thus offered the potential of throwing new light on the autoxidation of cis-1,4-polyisoprene, especially in the very early stages or under ambient conditions where conventional spectroscopic procedures are rather insensitive.

  9. Antioxidant effects of aminosalicylates and potential new drugs for inflammatory bowel disease: assessment in cell-free systems and inflamed human colorectal biopsies.

    PubMed

    Simmonds, N J; Millar, A D; Blake, D R; Rampton, D S

    1999-03-01

    The therapeutic efficacy of 5-aminosalicylic acid in inflammatory bowel disease may be related to its antioxidant properties. To compare in vitro the antioxidant effects of conventional drugs (5-aminosalicylic acid, corticosteroids, metronidazole), with new aminosalicylates (4-aminosalicylic acid, balsalazide) and other potential therapies (ascorbate, N-acetylcysteine, glutathione, verapamil). Compounds were assessed for efficacy in reducing the in vitro production of reactive oxygen species by cell-free systems (using xanthine/xanthine oxidase, with or without myeloperoxidase) and by colorectal biopsies from patients with ulcerative colitis using luminol-amplified chemiluminescence. 5-aminosalicylic acid and balsalazide were more potent antioxidants than 4-aminosalicylic acid or N-acetyl-5-aminosalicylic acid in cell-free systems. 5-aminosalicylic acid (20 mM) and balsalazide (20 mM) inhibited rectal biopsy chemiluminescence by 93% and 100%, respectively, compared with only 59% inhibition by 4-aminosalicylic acid (20 mM). Hydrocortisone, metronidazole and verapamil had no significant effect on chemiluminescence in any system. Ascorbate (20 mM) inhibited chemiluminescence by 100% in cell-free systems and by 60% in rectal biopsies. N-acetyl cysteine (10 mM), and both oxidized and reduced glutathione (10 mM), completely inhibited chemiluminescence in cell-free systems, but not with rectal biopsies. The antioxidant effects of compounds varies between cell-free systems and inflamed colorectal biopsies. The effect of drugs on the chemiluminescence produced by these two assay systems is useful for screening potentially new antioxidant treatments for inflammatory bowel disease. Ascorbate seems worth further study as a novel therapy.

  10. Synthesis of Chemiluminescent Esters: A Combinatorial Synthesis Experiment for Organic Chemistry Students

    ERIC Educational Resources Information Center

    Duarte, Robert; Nielson, Janne T.; Dragojlovic, Veljko

    2004-01-01

    A group of techniques aimed at synthesizing a large number of structurally diverse compounds is called combinatorial synthesis. Synthesis of chemiluminescence esters using parallel combinatorial synthesis and mix-and-split combinatorial synthesis is experimented.

  11. Tube radial distribution phenomenon with a two-phase separation solution of a fluorocarbon and hydrocarbon organic solvent mixture in a capillary tube and metal compounds separation.

    PubMed

    Kitaguchi, Koichi; Hanamura, Naoya; Murata, Masaharu; Hashimoto, Masahiko; Tsukagoshi, Kazuhiko

    2014-01-01

    A fluorocarbon and hydrocarbon organic solvent mixture is known as a temperature-induced phase-separation solution. When a mixed solution of tetradecafluorohexane as a fluorocarbon organic solvent and hexane as a hydrocarbon organic solvent (e.g., 71:29 volume ratio) was delivered in a capillary tube that was controlled at 10°C, the tube radial distribution phenomenon (TRDP) of the solvents was clearly observed through fluorescence images of the dye, perylene, dissolved in the mixed solution. The homogeneous mixed solution (single phase) changed to a heterogeneous solution (two phases) with inner tetradecafluorohexane and outer hexane phases in the tube under laminar flow conditions, generating the dynamic liquid-liquid interface. We also tried to apply TRDP to a separation technique for metal compounds. A model analyte mixture, copper(II) and hematin, was separated through the capillary tube, and detected with a chemiluminescence detector in this order within 4 min.

  12. Quality assured measurements of animal building emissions: gas concentrations.

    PubMed

    Heber, Albert J; Ni, Ji-Qin; Lim, Teng T; Tao, Pei-Chun; Schmidt, Amy M; Koziel, Jacek A; Beasley, David B; Hoff, Steven J; Nicolai, Richard E; Jacobson, Larry D; Zhang, Yuanhui

    2006-10-01

    Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 microm in diameter, and total suspended particulate from swine and poultry production buildings in the United States. This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with > or =10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.

  13. Pyrophosphate as substrate for alkaline phosphatase activity: A convenient flow-injection chemiluminescence assay.

    PubMed

    Zhang, Qingfeng; Zhang, Cuiyun; Yang, Meiding; Yu, Donghong; Yu, Cong

    2017-11-01

    A sensitive and convenient flow-injection chemiluminescence (FI-CL) turn-on assay for alkaline phosphatase (ALP) activity without any label and synthesis is developed. Cu 2+ can catalyze the luminol-H 2 O 2 CL reaction. Pyrophosphate (PPi) can chelate Cu 2+ and therefore the Cu 2+ -mediated luminol-H 2 O 2 CL reaction is inhibited. The addition of ALP can catalyze the hydrolysis of PPi into phosphate ions, Cu 2+ is released and the chemiluminescence recovers. A detection limit of 1 mU/mL ALP is obtained. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Line scanning system for direct digital chemiluminescence imaging of DNA sequencing blots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karger, A.E.; Weiss, R.; Gesteland, R.F.

    A cryogenically cooled charge-coupled device (CCD) camera equipped with an area CCD array is used in a line scanning system for low-light-level imaging of chemiluminescent DNA sequencing blots. Operating the CCD camera in time-delayed integration (TDI) mode results in continuous data acquisition independent of the length of the CCD array. Scanning is possible with a resolution of 1.4 line pairs/mm at the 50% level of the modulation transfer function. High-sensitivity, low-light-level scanning of chemiluminescent direct-transfer electrophoresis (DTE) DNA sequencing blots is shown. The detection of DNA fragments on the blot involves DNA-DNA hybridization with oligonucleotide-alkaline phosphatase conjugate and 1,2-dioxetane-based chemiluminescence.more » The width of the scan allows the recording of up to four sequencing reactions (16 lanes) on one scan. The scan speed of 52 cm/h used for the sequencing blots corresponds to a data acquisition rate of 384 pixels/s. The chemiluminescence detection limit on the scanned images is 3.9 [times] 10[sup [minus]18] mol of plasmid DNA. A conditional median filter is described to remove spikes caused by cosmic ray events from the CCD images. 39 refs., 9 refs.« less

  15. Micromachined microfluidic chemiluminescent system for explosives detection

    NASA Astrophysics Data System (ADS)

    Park, Yoon; Neikirk, Dean P.; Anslyn, Eric V.

    2007-04-01

    Results will be reported from efforts to develop a self-contained micromachined microfluidic detection system for the presence of specific target analytes under the US Office of Naval Research Counter IED Basic Research Program. Our efforts include improving/optimizing a dedicated micromachined sensor array with integrated photodetectors and the synthesis of chemiluminescent receptors for nitramine residues. Our strategy for developing chemiluminescent synthetic receptors is to use quenched peroxyoxalate chemiluminescence; the presence of the target analyte would then trigger chemiluminescence. Preliminary results are encouraging as we have been able to measure large photo-currents from the reaction. We have also fabricated and demonstrated the feasibility of integrating photodiodes within an array of micromachined silicon pyramidal cavities. One particular advantage of such approach over a conventional planar photodiode would be its collection efficiency without the use of external optical components. Unlike the case of a normal photodetector coupled to a focused or collimated light source, the photodetector for such a purpose must couple to an emitting source that is approximately hemispherical; hence, using the full sidewalls of the bead's confining cavity as the detector allows the entire structure to act as its own integrating sphere. At the present time, our efforts are concentrating on improving the signal-to-noise ratio by reducing the leakage current by optimizing the fabrication sequence and the design.

  16. Acidic Potassium Permanganate Chemiluminescence for the Determination of Antioxidant Potential in Three Cultivars of Ocimum basilicum.

    PubMed

    Srivastava, Shivani; Adholeya, Alok; Conlan, Xavier A; Cahill, David M

    2016-03-01

    Ocimum basilicum, a member of the family Lamiaceae, is a rich source of polyphenolics that have antioxidant properties. The present study describes the development and application of an online HPLC-coupled acidic potassium permanganate chemiluminescence assay for the qualitative and quantitative assessment of antioxidants in three cultivars of O. basilicum grown under greenhouse conditions. The chemiluminescence based assay was found to be a sensitive and efficient method for assessment of total and individual compound antioxidant potential. Leaves, flowers and roots were found to be rich reserves of the antioxidant compounds which showed intense chemiluminescence signals. The polyphenolics such as rosmarinic, chicoric, caffeic, p-coumaric, m-coumaric and ferulic acids showed antioxidant activity. Further, rosmarinic acid was found to be the major antioxidant component in water-ethanol extracts. The highest levels of rosmarinic acid was found in the leaves and roots of cultivars "holy green" (14.37; 11.52 mM/100 g DW respectively) followed by "red rubin" (10.02; 10.75 mM/100 g DW respectively) and "subja" (6.59; 4.97 mM/100 g DW respectively). The sensitivity, efficiency and ease of use of the chemiluminescence based assay should now be considered for its use as a primary method for the identification and quantification of antioxidants in plant extracts.

  17. Influence of dichloromethylene bisphosphonate on the in vitro phagocytosis of hydroxyapatite particles by rat peritoneal exudate cells: an electron microscopic and chemiluminescence study.

    PubMed Central

    Hyvönen, P M; Kowolik, M J

    1992-01-01

    Transmission electron microscopy and standard chemiluminescence assays were used to investigate the in vivo effect of dichloromethylene bisphosphonate (clodronate) on the phagocytosis of pure hydroxyapatite particles by rat peritoneal macrophages and the production of chemiluminescence by the peritoneal exudate cells. Hydroxyapatite (control) and a hydroxyapatite/clodronate suspension (28 mumol clodronate per gram of hydroxyapatite, experimental) were injected into the peritoneum of rats, the clodronate dose being 10 micrograms/kg. Macrophages were harvested at 12, 24, 48, and 96 hours after injection and the particle phagocytosis was assessed by transmission electron microscopy. Hydroxyapatite alone was completely phagocytosed by 24 hours and hydroxyapatite reacted with clodronate was completely phagocytosed by 48 hours. From 48 hours onwards hydroxyapatite particle dissolution was observed in the phagosomes of cells in the two groups. At 48 hours the chemiluminescence produced by the peritoneal exudate cells was also measured. Clodronate and clodronate/hydroxyapatite enhanced cell activity on subsequent challenge with phorbol myristate acetate or zymosan. Clodronate seemed to exhibit an inhibitory effect on the phagocytic activity and an enhancement of the chemiluminescence production by the cells in this model, indicating that it was modifying the inflammatory cell response. Images PMID:1532298

  18. Laser-Based Diagnostic Measurements of Low Emissions Combustor Concepts

    NASA Technical Reports Server (NTRS)

    Hicks, Yolanda R.

    2011-01-01

    This presentation provides a summary of primarily laser-based measurement techniques we use at NASA Glenn Research Center to characterize fuel injection, fuel/air mixing, and combustion. The report highlights using Planar Laser-Induced Fluorescence, Particle Image Velocimetry, and Phase Doppler Interferometry to obtain fuel injector patternation, fuel and air velocities, and fuel drop sizes and turbulence intensities during combustion. We also present a brief comparison between combustors burning standard JP-8 Jet fuel and an alternative fuels. For this comparison, we used flame chemiluminescence and high speed imaging.

  19. Solid-phase receptor-based assay for the detection of cyclic imines by chemiluminescence, fluorescence, or colorimetry.

    PubMed

    Rodríguez, Laura P; Vilariño, Natalia; Molgó, Jordi; Aráoz, Rómulo; Antelo, Alvaro; Vieytes, Mercedes R; Botana, Luis M

    2011-08-01

    The spirolides and gymnodimines are marine phycotoxins included in the group of cyclic imines. The toxicity of these compounds to humans is still unknown, although their toxicity by intraperitoneal injection in rodents is very high. A receptor-based method was developed using the competition of the 13-desmethyl spirolide C with biotin-labeled α-bungarotoxin for binding to nicotinic acetylcholine receptors and the immobilization of the α-bungarotoxin-receptor complex on streptavidin-coated surfaces. The quantification of the immobilized receptor can be achieved using a specific antibody. Finally, after the addition of a secondary antibody labeled with horseradish peroxidase, three alternative substrates of this enzyme generate a chemiluminescent, fluorescent, or colorimetric signal. The assay performs well in shellfish extracts and the detection range is 5-150 nM of 13-desmethyl spirolide C in shellfish extracts, which is at least 5 times more sensitive than the existing fluorescence polarization assay. This assay can also detect gymnodimine, although with 10 times lower sensitivity than the spirolide. The detection of cyclic imines with microplate assays would be useful for screening purposes in order to reduce the number of samples to be processed by bioassays or analytical methods.

  20. Fast nucleation for silica nanoparticle synthesis using a sol-gel method.

    PubMed

    Dixit, Chandra K; Bhakta, Snehasis; Kumar, Ajeet; Suib, Steven L; Rusling, James F

    2016-12-01

    We have developed a method that for the first time allowed us to synthesize silica particles in 20 minutes using a sol-gel preparation. Therefore, it is critically important to understand the synthesis mechanism and kinetic behavior in order to achieve a higher degree of fine tuning ability during the synthesis. In this study, we have employed our ability to modulate the physical nature of the reaction medium from sol-gel to emulsion, which has allowed us to halt the reaction at a particular time; this has allowed us to precisely understand the mechanism and chemistry of the silica polymerization. The synthesis medium is kept quite simple with tetraethyl orthosilicate (TEOS) as a precursor in an equi-volumetric ethanol-water system and with sodium hydroxide as a catalyst. Synthesis is performed under ambient conditions at 20 °C for 20 minutes followed by phasing out of any unreacted TEOS and polysilicic acid chains via their emulsification with supersaturated water. We have also demonstrated that the developed particles with various sizes can be used as seeds for further particle growth and other applications. Luminol, a chemiluminescent molecule, has been entrapped successfully between the layers of silica and was demonstrated for the chemiluminescence of these particles.

  1. Peroxyoxalate chemiluminescence detection for the highly sensitive determination of fluorescence-labeled chlorpheniramine with Suzuki coupling reaction.

    PubMed

    Adutwum, Lawrence Asamoah; Kishikawa, Naoya; Ohyama, Kaname; Harada, Shiro; Nakashima, Kenichiro; Kuroda, Naotaka

    2010-09-01

    A sensitive and selective high performance liquid chromatography-peroxyoxalate chemiluminescence (PO-CL) method has been developed for the simultaneous determination of chlorpheniramine (CPA) and monodesmethyl chlorpheniramine (MDCPA) in human serum. The method combines fluorescent labeling with 4-(4,5-diphenyl-1H-imidazole-2-yl)phenyl boronic acid using Suzuki coupling reaction with PO-CL detection. CPA and MDCPA were extracted from human serum by liquid-liquid extraction with n-hexane. Excess labeling reagent, which interfered with trace level determination of analytes, was removed by solid-phase extraction using a C18 cartridge. Separation of derivatives of both analytes was achieved isocratically on a silica column with a mixture of acetonitrile and 60 mM imidazole-HNO(3) buffer (pH 7.2; 85:15, v/v) containing 0.015% triethylamine. The proposed method exhibited a good linearity with a correlation coefficient of 0.999 for CPA and MDCPA within the concentration range of 0.5-100 ng/mL. The limits of detection (S/N = 3) were 0.14 and 0.16 ng/mL for CPA and MDCPA, respectively. Using the proposed method, CPA could be selectively determined in human serum after oral administration.

  2. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  3. 40 CFR 91.4 - Acronyms and abbreviations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon monoxide CO2—Carbon...—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—Independent... OEM—Original engine manufacturer PMD—paramagnetic detector PWC—personal watercraft RPM—revolutions per...

  4. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  5. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  6. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  7. 40 CFR 91.4 - Acronyms and abbreviations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon monoxide CO2—Carbon...—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—Independent... OEM—Original engine manufacturer PMD—paramagnetic detector PWC—personal watercraft RPM—revolutions per...

  8. 40 CFR 91.4 - Acronyms and abbreviations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon monoxide CO2—Carbon...—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—Independent... OEM—Original engine manufacturer PMD—paramagnetic detector PWC—personal watercraft RPM—revolutions per...

  9. 40 CFR 91.4 - Acronyms and abbreviations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon monoxide CO2—Carbon...—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—Independent... OEM—Original engine manufacturer PMD—paramagnetic detector PWC—personal watercraft RPM—revolutions per...

  10. 40 CFR 91.4 - Acronyms and abbreviations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon monoxide CO2—Carbon...—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—Independent... OEM—Original engine manufacturer PMD—paramagnetic detector PWC—personal watercraft RPM—revolutions per...

  11. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  12. Flow-injection chemiluminescence determination of acetylsalicylic acid based on its enhancing effect on the lucigenin–hydrogen peroxide system.

    PubMed

    Wabaidur, S M; Alam, S M; Alothmana, Z A; Eldesokya, Gaber

    2014-09-01

    A sensitive flow-injection chemiluminescence method for the determination of acetylsalicylic acid is described. It is based on the enhanced chemiluminescent emission of the alkaline lucigenin–H2O2 system by acetylsalicylic acid. The difference in chemiluminescent intensity of alkaline lucigenin–H2O2 in the presence of acetylsalicylic acid from that in the absence of acetylsalicylic acid was linear at acetylsalicylic acid concentrations in the range of 0.0029–47.37 μg/mL, with detection and quantification limits of 0.0011 and 0.0029 μg/mL, respectively. The correlation coefficient of the working curve was 0.9983. The relative standard deviation (n = 10) for 25 μg/mL acetylsalicylic acid is 1.95%. All experimental parameters were optimized. The method was successfully applied to the determination of acetylsalicylic acid in pharmaceutical preparations. The recovery results obtained by the method were satisfactory.

  13. Enhancing and inhibiting effects of aromatic compounds on luminol-dimethylsulfoxide-OH(-) chemiluminescence and determination of intermediates in oxidative hair dyes by HPLC with chemiluminescence detection.

    PubMed

    Zhou, Jian; Xu, Hong; Wan, Guo-Hui; Duan, Chun-Feng; Cui, Hua

    2004-10-08

    The effect of 36 aromatic compounds on the luminol-dimethylsulfoxide-OH(-) chemiluminescence (CL) was systematically studied. It was found that dihydroxybenzenes, and ortho- and para-substituted aminophenols and phenylenediamines inhibited the CL and phenols with three or more than three hydroxyls except phloroglucin tended to enhance the CL. The CL inhibition and enhancement was proposed to be dependent on whether superoxide anion radical (O(2)(-)) was competitively consumed by compounds in the CL system. Trihydroxybenzenes were capable of generating superoxide anion radical, leading to the CL enhancement, whereas dihydroxybenzenes were superoxide anion radical scavenger, causing the CL inhibition. Based on the inhibited CL, a novel method for the simultaneous determination of p-phenylenediamine, o-phenylenediamine, p-aminophenol, o-aminophenol, resorcinol and hydroquinone by high-performance liquid chromatography coupled with chemiluminescence detection was developed. The method has been successfully applied to determine intermediates in oxidative hair dyes and wastewater of shampooing after hair dyed.

  14. Screening test for rapid food safety evaluation by menadione-catalysed chemiluminescent assay.

    PubMed

    Yamashoji, Shiro; Yoshikawa, Naoko; Kirihara, Masayuki; Tsuneyoshi, Toshihiro

    2013-06-15

    The chemiluminescent assay of menadione-catalysed H2O2 production by living mammalian cells was proposed to be useful for rapid food safety evaluation. The tested foods were extracted with water, ethanol and dimethylsulfoxide, and each extract was incubated with NIH3T3, Neuro-2a and HepG2 cells for 4h. Menadione-catalysed H2O2 production by living mammalian cells exposed to each extract was determined by the chemiluminescent assay requiring only 10 min, and the viability of the cells was estimated as percentage based on H2O2 production by intact cells. In this study the cytotoxicity of food was rated in order of inhibitory effect on H2O2 production by intact cells. The well known natural toxins such as Fusarium mycotoxin, tomato toxin tomatine, potato toxin solanine and marine toxins terodotoxin and brevetoxin could be detected by the above chemiluminescent assay. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Chemiluminescence and chemiluminescence resonance energy transfer (CRET) aptamer sensors using catalytic hemin/G-quadruplexes.

    PubMed

    Liu, Xiaoqing; Freeman, Ronit; Golub, Eyal; Willner, Itamar

    2011-09-27

    The incorporation of hemin into the thrombin/G-quadruplex aptamer assembly or into the ATP/G-quadruplex nanostructure yields active DNAzymes that catalyze the generation of chemiluminescence. These catalytic processes enable the detection of thrombin and ATP with detection limits corresponding to 200 pM and 10 μM, respectively. The conjugation of the antithrombin or anti-ATP aptamers to CdSe/ZnS semiconductor quantum dots (QDs) allowed the detection of thrombin or ATP through the luminescence of the QDs that is powered by a chemiluminescence resonance energy-transfer (CRET) process stimulated by the hemin/G-quadruplex/thrombin complex or the hemin/G-quadruplex/ATP nanostructure, in the presence of luminol/H(2)O(2). The advantages of applying the CRET process for the detection of thrombin or ATP, by the resulting hemin/G-quadruplex DNAzyme structures, are reflected by low background signals and the possibility to develop multiplexed aptasensor assays using different sized QDs. © 2011 American Chemical Society

  16. Flow injection chemiluminescent determination of tetracycline using a tris(2,2'-bipyridine)ruthenium(II)-cerium(IV) sulphate system.

    PubMed

    Guo, Liangqia; Xie, Zenghong; Lin, Xucong; Liu, Xiaohua; Zhang, Weilin; Chen, Guonan

    2004-01-01

    A flow-injection chemiluminescence method for the determination of tetracycline was developed. The method is based on an enhancement by tetracycline of the chemiluminescence light emission of tris(2,2'-bipyridine)ruthenium(II). In sulphuric acid medium, the chemiluminescence is generated by the continuous oxidation of tris(2,2'-bipyridine)ruthenium(II) by cerium (IV) sulphate. The light-emission intensity is greatly enhanced in the presence of tetracycline. Under the optimum conditions, the calibration curve is linear over the range 3.75 x 10(-8) g/mL-1.5 x 10(-5) g/mL for tetracycline with the linear equation: deltaINT = 205.898 x C - 20.442 (R2 = 0.9974). The detection limit is 3.27 x 10(-8) g/mL. The proposed method was also successfully used to determine tetracycline in pharmaceutical formulation (mean recovery of tetracycline, 100.7%). Copyright 2004 John Wiley & Sons, Ltd.

  17. beta 2-glycoprotein I (apolipoprotein H) modulates uptake and endocytosis associated chemiluminescence in rat Kupffer cells.

    PubMed

    Gomes, L F; Gonçalves, L M; Fonseca, F L A; Celli, C M; Videla, L A; Chaimovich, H; Junqueira, V B C

    2002-07-01

    beta 2-Glycoprotein I (beta 2 GPI) is known to influence macrophage uptake of particles with phosphatidylserine containing surfaces, as apoptotic thymocytes and unilamellar vesicles in vitro. Nevertheless, effects upon macrophage activation induced by this interaction are still unknown. beta 2 GPI influence upon the reactive species production by Kupffer cells was evaluated in order to investigate whether beta 2 GPI modulates the macrophage response to negatively charged surfaces. Chemiluminescence of isolated non-parenchymal rat liver cells was measured after phagocytosis of opsonized zymosan or phorbolymristate acetate (PMA) stimulation, in the presence and absence of large unilamellar vesicles (LUVs) containing 25 mol% phosphatidylserine (PS) or 50 mol% cardiolipin (CL) and complementary molar ratio of phosphatidylcholine (PC). beta 2 GPI decreased by 50% the chemiluminescence response induced by opsonized zymosan, with a 66% reduction of the initial light emission rate. PMA stimulated Kupffer cell chemiluminescence was insensitive to human or rat beta 2 GPI. Albumin (500 micrograms/ml) showed no effect upon chemiluminescence. beta 2 GPI increased PS/PC LUV uptake and degradation by Kupffer cells in a concentration-dependent manner, without leakage of the internal contents of the LUVs, as shown by fluorescence intensity enhancement. LUVs opsonized with antiphospholipid antibodies (aPL) from syphilitic patients increased light emission by Kupffer cells. Addition of beta 2 GPI to the assay reduced chemiluminescence due to opsonization with purified IgG antibodies from systemic lupus erythematosus (SLE or syphilis (Sy) patient sera. A marked net increase in chemiluminescence is observed in the presence of Sy aPL antibodies, whereas a decrease was found when SLE aPL were added to the assay, in the presence or absence of beta 2 GPI. At a concentration of 125 micrograms/ml, beta 2 GPI significantly reduced Kupffer cell Candida albicans phagocytosis index and killing score by 50 and 10%, respectively. The present data strongly suggest that particle uptake in the presence of beta 2 GPI is coupled to an inhibition of reactive species production by liver macrophages during the respiratory burst, supporting the role of beta 2 GPI as a mediator of senescent cell removal.

  18. The Synthesis and Chemiluminescence of a Stable 1,2-Dioxetane.

    ERIC Educational Resources Information Center

    Meijer, E. W.; Wynberg, Hans

    1982-01-01

    Background information, laboratory procedures, and discussion of results are provided for the synthesis and chemiluminescence of adamantylideneadamantane-1,2-dioxetane (I). Results provided were obtained during a normal junior level organic laboratory course. All intermediates and products were identified using routine spectroscopic analysis.…

  19. Automated Flow-Injection Instrument for Chemiluminescence Detection Using a Low-Cost Photodiode Detector

    ERIC Educational Resources Information Center

    Economou, A.; Papargyris, D.; Stratis, J.

    2004-01-01

    The development of an FI analyzer for chemiluminescence detection using a low-cost photoiodide is presented. The experiment clearly demonstrates in a single interdisciplinary project the way in which different aspects in chemical instrumentation fit together to produce a working analytical system.

  20. Flow injection chemiluminescence determination of vitamin B12 using on-line UV-persulfate photooxidation and charge coupled device detection.

    PubMed

    Murillo Pulgarín, José A; García Bermejo, Luisa F; Sánchez García, M Nieves

    2011-01-01

    A sensitive chemiluminescence method for vitamin B(12) using a charge-coupled device (CCD) photodetector combined with on-line UV-persulfate oxidation in a simple continuous flow system has been developed. The principle for the determination of vitamin B(12) is based on the enhancive effect of cobalt (II) on the chemiluminescence reaction between luminol and percarbonate in alkaline medium. In addition, percarbonate has been investigated and proposed as a powerful source of hydrogen peroxide as oxidant agent in this chemiluminescence reaction. The digestion of vitamin B(12) to release the cobalt (II) is reached by UV irradiation treatment in a persulfate medium. The CCD detector, directly connected to the flow cell, is used with the continuous flow manifold to obtain the full spectral characteristics of cobalt (II) catalyzed luminol-percarbonate reaction. The vitamin B(12) oxidation process and chemical conditions for the chemiluminescence reaction were investigated and optimized. The increment of the emission intensity was proportional to the concentration of vitamin B(12) , giving a second-order calibration graph over the cobalt (II) concentration range from 10 to 5000 μg L(-1)(r(2) = 0.9985) with a detection limit of 9.3 μg L(-1). The proposed method was applied to the determination of vitamin B(12) in different kinds of pharmaceuticals. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Review of Federal Reference Method for Ozone: Nitric Oxide-Chemiluminescence:Supplemental Material for CASAC AMMS

    EPA Science Inventory

    ApproachPer suggestion made by CASAC AMMS members during the April 3, 2014 conference call on the Review of Federal Reference Method for Ozone: Nitric Oxide-Chemiluminescence, ORD has performed additional data analysis activities to explain and mitigate scatter observed in the co...

  2. Evaluation of endotoxin (LPS) activity in bovine blood using neutrophil dependent chemiluminescence

    USDA-ARS?s Scientific Manuscript database

    The purpose of this study was to evaluate the applicability of a neutrophil chemiluminescence-based assay for the measurement of LPS stimulatory activity in bovine whole blood. The assay is based on the capacity for LPS to trigger the respiratory oxidative burst activity (RBA) of autologous neutroph...

  3. Chemiluminescent Oscillating Demonstrations: The Chemical Buoy, the Lighting Wave, and the Ghostly Cylinder

    ERIC Educational Resources Information Center

    Prypsztejn, Hernan E.; Mulford, Douglas R.; Stratton, Doug

    2005-01-01

    Oscillating reactions have been extensively used in chemical demonstrations. They involve several chemical concepts about kinetics, catalysts, and thermodynamics. The spontaneous cyclic color change of a solution is an attraction in any educational-level course. Chemiluminescent reactions are also among the most fascinating demonstrations and have…

  4. [Comparative research into sensitivity and specificity of immune-enzyme analysis with chemiluminescence and colorimetric detection for detecting antigens and antibodies to avian influenza viruses and newcastle disease].

    PubMed

    Vitkova, O N; Kapustina, T P; Mikhailova, V V; Safonov, G A; Vlasova, N N; Belousova, R V

    2015-01-01

    The goal of this work was to demonstrate the results of the development of the enzyme-linked immunosorbent tests with chemiluminescence detection and colorimetric detection of specific viral antigens and antibodies for identifying the avian influenza and the Newcastle disease viruses: high sensitivity and specificity of the immuno- chemiluminescence assay, which are 10-50 times higher than those of the ELISA colorimetric method. The high effectiveness of the results and the automation of the process of laboratory testing (using a luminometer) allow these methods to be recommended for including in primary screening tests for these infectious diseases.

  5. Facile synthesis of hollow Co3O4 microspheres and its use as a rapid responsive CL sensor of combustible gases.

    PubMed

    Teng, Fei; Yao, Wenqing; Zheng, Youfei; Ma, Yutao; Xu, Tongguang; Gao, Guizhi; Liang, Shuhui; Teng, Yang; Zhu, Yongfa

    2008-09-15

    The hollow Co(3)O(4) microspheres (HCMs) were prepared by the carbonaceous templates, which did not need the surface pretreatment. The chemiluminescence (CL) and catalytic properties for CO oxidation over these hollow samples were evaluated. The samples were characterized by scanning electron microscopy (SEM), energy disperse spectra (EDS), transmission electron microscopy (TEM), selected area electron diffraction (ED), X-ray diffraction (XRD), temperature-programmed desorption (TPD) and N(2) adsorption. The influences of filter' band length, flow rate of gas, test temperature, and particle structure on CL intensities were mainly investigated. It was found that compared with the solid Co(3)O(4) particles (SCPs), HCMs had a stronger CL intensity, which was ascribed to its hollow structure; and that CL properties of the catalysts were well correlated with their reaction activities. Moreover, HCMs were used to fabricate a highly sensitive gas detector, which is a rapid and effective method for the selection of catalysts or the detection of environmental deleterious gases.

  6. Chemiluminescence: Measuring methods. (Latest citations from the NTIS bibliographic database). Published Search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The bibliography contains citations concerning chemiluminescence assays. The citations include sample system design, sample collection, measurement techniques, and sensitivity of the instrumentation. Applications in high altitude air pollution studies are emphasized. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  7. Nanoparticles based on quantum dots and a luminol derivative: implications for in vivo imaging of hydrogen peroxide by chemiluminescence resonance energy transfer.

    PubMed

    Lee, Eun Sook; Deepagan, V G; You, Dong Gil; Jeon, Jueun; Yi, Gi-Ra; Lee, Jung Young; Lee, Doo Sung; Suh, Yung Doug; Park, Jae Hyung

    2016-03-18

    Overproduction of hydrogen peroxide is involved in the pathogenesis of inflammatory diseases such as cancer and arthritis. To image hydrogen peroxide via chemiluminescence resonance energy transfer in the near-infrared wavelength range, we prepared quantum dots functionalized with a luminol derivative.

  8. A competitive aptamer chemiluminescence assay for ochratoxin A using a single silica photonic crystal microsphere.

    PubMed

    Shen, Peng; Li, Wei; Ding, Zhi; Deng, Yang; Liu, Yan; Zhu, Xuerui; Cai, Tingting; Li, Jianlin; Zheng, Tiesong

    2018-08-01

    We designed a competitive aptamer chemiluminescence assay for ochratoxin A (OTA) on the surface of a single silica photonic crystal microsphere (SPCM) in cereal samples. The structural color of SPCMs is used to recognize and trace the microspheres during process of detection. Anti-aptamer was immobilized on the surface of SPCM. OTA and anti-aptamer competed to bind to aptamer when OTA and its aptamer (labeled by biotin at 5'end) were added in the system. The chemiluminescence signal was developed by the horseradish peroxidase (HRP), luminol and H 2 O 2 . The molecules on the single SPCM can produce enough chemiluminescence signal intensity for quantitative detection for OTA. The linear detection range for OTA was from 1 pg/mL to 1 ng/mL and recovery rates were 89%-95%, 81%-92% and 94%-105% in rice, wheat and corn, respectively. The results showed that the developed method for OTA using a single SPCM has a great application potential in cereal samples. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Fe3O4 and metal-organic framework MIL-101(Fe) composites catalyze luminol chemiluminescence for sensitively sensing hydrogen peroxide and glucose.

    PubMed

    Qian Tang, Xue; Dan Zhang, Yi; Wei Jiang, Zhong; Mei Wang, Dong; Zhi Huang, Cheng; Fang Li, Yuan

    2018-03-01

    In this work, Fe 3 O 4 and metal-organic framework MIL-101(Fe) composites (Fe 3 O 4 /MIL-101(Fe)) was demonstrated to possess excellent catalytic property to directly catalyze luminol chemiluminescence without extra oxidants. We utilized Fe 3 O 4 /MIL-101(Fe) to develop a ultra-sensitive quantitative analytical method for H 2 O 2 and glucose. The possible mechanism of the chemiluminescence reaction had been investigated. Under optimal conditions, the relative chemiluminescence intensity was linearly proportional to the logarithm of H 2 O 2 concentration in the range of 5-150nM with a limit of detection of 3.7nM (signal-to-noise ratio = 3), and glucose could be linearly detected in the range from 5 to 100nM and the detection limit was 4.9nM (signal-to-noise ratio = 3). Furthermore, the present approach was successfully applied to quantitative determination of H 2 O 2 in medical disinfectant and glucose in human serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Stable and general-purpose chemiluminescent detection system for horseradish peroxidase employing a thiazole compound enhancer and some additives.

    PubMed

    Iwata, R; Ito, H; Hayashi, T; Sekine, Y; Koyama, N; Yamaki, M

    1995-10-10

    A stable and highly sensitive chemiluminescent detection system for horseradish peroxidase (HRP)/luminol/hydrogen peroxide using a newly designed thiazole compound enhancer has been established. Some additives for the chemiluminescent reaction were explored to overcome some defects of the reaction such as rapid decay and high background of light emission. Recrystallization of luminol and the addition of several detergents into the reacting solution were effective to increase specific light emissions. The addition of skim milk into the reacting solution reduced the background. Consequently, skim milk combined with a detergent increased the signal to noise ratio about 20 times compared with the reactions in the absence of both additives. The optimal concentration of enhancer and the addition of egg albumin stabilized the emission. In the new method, 6x 10(-18) mol of HRP was detectable. This would be the most sensitive enhanced chemiluminescent detection system for HRP. Furthermore, we could detect picogram per milliliter (10(-17) mol) concentrations of a trace component in biological materials such as endothelin-1 by employing this reaction.

  11. Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index.

    PubMed

    Nalewajko-Sieliwoniuk, Edyta; Iwanowicz, Magdalena; Kalinowski, Sławomir; Kojło, Anatol

    2016-03-10

    In this work, we present a novel chemiluminescence (CL) method based on direct-injection detector (DID) integrated with the multi-pumping flow system (MPFS) to chemiluminescence determination of the total polyphenol index. In this flow system, the sample and the reagents are injected directly into the cone-shaped detection cell placed in front of the photomultiplier window. Such construction of the detection chamber allows for fast measurement of the CL signal in stopped-flow conditions immediately after mixing the reagents. The proposed DID-CL-MPFS method is based on the chemiluminescence of nanocolloidal manganese(IV)-hexametaphosphate-ethanol system. The application of ethanol as a sensitizer, eliminated the use of carcinogenic formaldehyde. Under the optimized experimental conditions, the chemiluminescence intensities are proportional to the concentration of gallic acid in the range from 5 to 350 ng mL(-1). The DID-CL-MPFS method offers a number of advantages, including low limit of detection (0.80 ng mL(-1)), high precision (RSD = 3.3%) and high sample throughput (144 samples h(-1)) as well as low consumption of reagents, energy and low waste generation. The proposed method has been successfully applied to determine the total polyphenol index (expressed as gallic acid equivalent) in a variety of plant-derived food samples (wine, tea, coffee, fruit and vegetable juices, herbs, spices). Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Label-free genotyping of cytochrome P450 2D6*10 using ligation-mediated strand displacement amplification with DNAzyme-based chemiluminescence detection.

    PubMed

    Wang, Hong-Qi; Wu, Zhan; Zhang, Yan; Tang, Li-Juan; Yu, Ru-Qin; Jiang, Jian-Hui

    2012-01-13

    Genotyping of cytochrome P450 monooxygenase 2D6*10 (CYP2D6*10) plays an important role in pharmacogenomics, especially in clinical drug therapy of Asian populations. This work reported a novel label-free technique for genotyping of CYP2D6*10 based on ligation-mediated strand displacement amplification (SDA) with DNAzyme-based chemiluminescence detection. Discrimination of single-base mismatch is firstly accomplished using DNA ligase to generate a ligation product. The ligated product then initiates a SDA reaction to produce aptamer sequences against hemin, which can be probed by chemiluminescence detection. The proposed strategy is used for the assay of CYP2D6*10 target and the genomic DNA. The results reveal that the proposed technique displays chemiluminescence responses in linear correlation to the concentrations of DNA target within the range from 1 pM to 1 nM. A detection limit of 0.1 pM and a signal-to-background ratio of 57 are achieved. Besides such high sensitivity, the proposed CYP2D6*10 genotyping strategy also offers superb selectivity, great robustness, low cost and simplified operations due to its label-free, homogeneous, and chemiluminescence-based detection format. These advantages suggest this technique may hold considerable potential for clinical CYP2D6*10 genotyping and association studies. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Inhibition of peripheral blood neutrophil oxidative burst in periodontitis patients with a homeopathic medication Traumeel S

    PubMed Central

    žilinskas, Juozas; žekonis, Jonas; žekonis, Gediminas; Šadzevičienė, Renata; Sapragonienė, Marija; Navickaitė, Justina; Barzdžiukaitė, Ingrida

    2011-01-01

    Summary Background The anti-inflammatory effects of a homeopathic remedy, Traumeel S, have been observed in experimental and clinical studies; however, its antioxidant properties have not been elucidated. The aim of the present study was to evaluate the antioxidant effects of Traumeel S on peripheral blood neutrophils in patients with periodontitis. Material/Methods The study was performed using venous blood of 22 individuals with chronic periodontitis and 21 healthy subjects. The antioxidant effects of Traumeel S on the production of reactive oxygen species by unstimulated and stimulated with unopsonized E. coli neutrophils were investigated using luminol- and lucigenin-dependent chemiluminescence (CL). Results Polymorphonuclear leukocytes of periodontitis patients produced higher levels (p<0.01) of light output of lucigenin-dependent chemiluminescence and significantly reduced (p<0.01) light output of luminol-dependent chemiluminescence than analogous cells of healthy subjects. Highly diluted (10−4 of the stem solution) Traumeel S significantly (by approximately 50%) reduced superoxide-induced oxidation of lucigenin by unstimulated and stimulated with unopsonized E. coli polymorphonuclear leukocytes of periodontitis patients and had a tendency to intensify luminol-dependent chemiluminescence. Preincubation of the unstimulated and stimulated with unopsonized E. coli polymorphonuclear leukocytes of healthy subjects with Traumeel S exerts no inhibitory action on the luminol- and lucigenin-dependent chemiluminescence of the above-mentioned cells. Conclusions This study indicates that Traumeel S may significantly reduce production of superoxide anion by unstimulated and stimulated peripheral blood polymorphonuclear neutrophils of periodontitis patients. PMID:21525811

  14. Direct-injection chemiluminescence detector. Properties and potential applications in flow analysis.

    PubMed

    Koronkiewicz, Stanislawa; Kalinowski, Slawomir

    2015-02-01

    We present a novel chemiluminescence detector, with a cone-shaped detection chamber where the analytical reaction takes place. The sample and appropriate reagents are injected directly into the chamber in countercurrent using solenoid-operated pulse micro-pumps. The proposed detector allows for fast measurement of the chemiluminescence signal in stop-flow conditions from the moment of reagents mixing. To evaluate potential applications of the detector the Fenton-like reaction with a luminol-H2O2 system and several transition metal ions (Co(2+), Cu(2+), Cr(3+), Fe(3+)) as a catalyst were investigated. The results demonstrate suitability of the proposed detector for quantitative analysis and for investigations of reaction kinetics, particularly rapid reactions. A multi-pumping flow system was designed and optimized. The developed methodology demonstrated that the shape of the analytical signals strongly depends on the type and concentration of the metal ions. The application of the detector in quantitative analysis was assessed for determination of Fe(III). The direct-injection chemiluminescence detector allows for a sensitive and repeatable (R.S.D. 2%) determination. The intensity of chemiluminescence increased linearly in the range from about 0.5 to 10 mg L(-1) Fe(III) with the detection limit of 0.025 mg L(-1). The time of analysis depended mainly on reaction kinetics. It is possible to achieve the high sampling rate of 144 samples per hour. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Thermal and photochemical reactions of NO2 on chromium(III) oxide surfaces at atmospheric pressure.

    PubMed

    Nishino, Noriko; Finlayson-Pitts, Barbara J

    2012-12-05

    While many studies of heterogeneous chemistry on Cr(2)O(3) surfaces have focused on its catalytic activity, less is known about chemistry on this surface under atmospheric conditions. We report here studies of the thermal and photochemical reactions of NO(2) on Cr(2)O(3) at one atm in air. In order to follow surface species, the interaction of 16-120 ppm NO(2) with a 15 nm Cr(2)O(3) thin film deposited on a germanium crystal was monitored in a flow system using attenuated total reflectance (ATR) coupled to a Fourier transform infrared (FTIR) spectrometer. Gas phase products were monitored in the effluent of an ~285 ppm NO(2)-air mixture that had passed over Cr(2)O(3) powder in a flow system. A chemiluminescence NO(y) analyzer, a photometric O(3) analyzer and a long-path FTIR spectrometer were used to probe the gaseous products. In the absence of added water vapor, NO(2) formed nitrate (NO(3)(-)) ions coordinated to Cr(3+). These surface coordinated NO(3)(-) were reversibly solvated by water under humid conditions. In both dry and humid cases, nitrate ions decreased during irradiation of the surface at 302 nm, and NO and NO(2) were generated in the gas phase. Under dry conditions, NO was the major gaseous product while NO(2) was the dominant species in the presence of water vapor. Heating of the surface after exposure to NO(2) led to the generation of both NO(2) and NO under dry conditions, but only NO(2) in the presence of water vapor. Elemental chromium incorporated into metal alloys such as stainless steel is readily oxidized in contact with ambient air, forming a chromium-rich metal oxide surface layer. The results of these studies suggest that active photo- and thermal chemistry will occur when boundary layer materials containing chromium(III) or chromium oxide such as stainless steel, roofs, automobile bumpers etc. are exposed to NO(2) under tropospheric conditions.

  16. Determination of Montelukast in Plasma Using β - Cyclodextrins Coated on CoFe2O4 Magnetic Nanoparticles in Luminol-H2O2 Chemiluminescence System Optimized by Doehlert Design.

    PubMed

    Samadi-Maybodi, Abdolraouf; Bakhtiar, Alireza; Fatemi, Mohammad Hossein

    2016-05-01

    A novel chemiluminescence method using β - cyclodextrins coated on CoFe2O4 magnetic nanoparticles is proposed for the chemiluminometric determination of montelukast in plasma. The effect of coated β - cyclodexterinon CoFe2O4 magnetic nanoparticles in the chemiluminescence of luminol-H2O2 system was investigated. It was found that β - cyclodexterin coated on CoFe2O4 magnetic nanoparticles could greatly enhance the chemiluminescence of the luminol-H2O2 system. Doehlert design was applied in order to optimize the number of experiments to be carried out to ascertain the possible interactions between the parameters and their effects on the chemiluminescence emission intensity. This design was selected because the levels of each variable may vary in a very efficient way with few experiments. Doehlert design and response surface methodology have been employed for optimization pH and concentrations of the components. Results showed under the optimized experimental conditions, the relative CL intensity (ΔI) is increased linearly in the concentration range of 0.003-0.586 μgml(-1) of montelukast with limit of detection (LOD) 1.09 × 10(-4) μgml(-1) at S/N ratio of 3, limit of quantitative (LOQ) 3.59 × 10(-4) μgml(-1) and the relative standard deviation 2.63 %. The method has been successfully applied to the determination of montelukast in plasma of human body. Results specified that relative chemiluminescence intensity (ΔI) has good proportional with the montelukast concentration with R(2) = 0.99979. The test of the recovery efficiency for known amounts of montelukast was also performed, the recoveries range obtained from 98.2 to 103.3 %, with RSDs of <4 % indicated that the proposed method was reliable.

  17. Analysis of oral lesion biopsies identified and evaluated by visual examination, chemiluminescence and toluidine blue.

    PubMed

    Epstein, J B; Silverman, S; Epstein, J D; Lonky, S A; Bride, M A

    2008-06-01

    Conventional visual examination and palpation remains the gold-standard for the identification of oral mucosal lesions. The purpose of this study was to investigate the adjunctive value of a chemiluminescent light source (ViziLite, Zila Pharmaceuticals, Phoenix, Arizona) and application of pharmaceutical grade toluidine blue (TBlue(630), Zila Pharmaceuticals, Phoenix, Arizona) to further assess lesions identified during the conventional oral soft tissue examination. Lesions deemed clinically suspicious by visual examination under incandescent light were further assessed under chemiluminescence and then application of toluidine blue stain. Differences between the conventional visual examination and chemiluminescent examination were noted on four characteristics which may aid in lesion identification. Tissue retention of toluidine blue stain was documented. Each suspicious lesion was biopsied and diagnosed based upon routine histopathology. Both adjunctive exams were evaluated by comparing the histologic diagnosis. The additive value of toluidine blue stain retention was assessed in lesions diagnosed as "serious pathology" defined as severe dysplasia, carcinoma in situ and squamous cell carcinoma. Ninety-seven clinically suspicious lesions in 84 patients were identified. The chemiluminescent exam improved the brightness and/or sharpness of margin in 61.8% of identified lesions. Biopsied lesions with toluidine blue stain retention reduced the false positive rate by 55.26% while maintaining a 100% negative predictive value (NPV). Chemiluminescence was shown to increase the brightness and margins of mucosal lesions in a majority of cases and therefore may assist in identification of mucosal lesions not considered under traditional visual examination. Toluidine blue stain retention was associated with a large reduction in biopsies showing benign histology (false positive biopsy results), while maintaining a 100% NPV for the presence of severe dysplasia or cancer. Practitioners may consider use of these adjuncts in practice, however the results presented are based upon experienced providers in referral centers for mucosal disease or cancer centers and therefore positive findings may be an indication for referral to experienced providers.

  18. Nitric acid oxide mixing ratio measurements using a rocket launched chemiluminescent instrument

    NASA Technical Reports Server (NTRS)

    Horvath, Jack J.

    1989-01-01

    A total of 18 rocket launched parachute borne nitric oxide instruments were launched from 1977 to 1985. A very precise instrument for the measurement of the nitric oxide mixing ratio was fabricated. No changes were made in the main body of the instruments, i.e., things associated with the reaction volume. Except for the last 4 launches, however, it did not yield the required absolute values that was hoped for. Two major problems were encountered. First, the wrong choice of the background calibration gas, nitrogen, caused the first 10 data sets to be too low in the absolute mixing ratio by nearly the order of 2 to 5 ppbv. The error was realized, and air was substituted for the bias gas measurement. Second, in the desire to extend the measurement to higher altitudes, the problem of contaminating the inlet flow tube with ozone from the reagent gas was encountered. The ozone valve was opened too early in the flight and this caused the pressure in the reaction volume to exceed the pressure at the flow tube entrance, permitting the ozone to migrate backwards. This problem was restricted to an altitude above 45 km.

  19. A sensitive chemiluminescence enzyme immunoassay based on molecularly imprinted polymers solid-phase extraction of parathion.

    PubMed

    Chen, Ge; Jin, Maojun; Du, Pengfei; Zhang, Chan; Cui, Xueyan; Zhang, Yudan; She, Yongxin; Shao, Hua; Jin, Fen; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2017-08-01

    The chemiluminescence enzyme immunoassay (CLEIA) method responds differently to various sample matrices because of the matrix effect. In this work, the CLEIA method was coupled with molecularly imprinted polymers (MIPs) synthesized by precipitation polymerization to study the matrix effect. The sample recoveries ranged from 72.62% to 121.89%, with a relative standard deviation (RSD) of 3.74-18.14%.The ratio of the sample matrix-matched standard curve slope rate to the solvent standard curve slope was 1.21, 1.12, 1.17, and 0.85 for apple, rice, orange and cabbage in samples pretreated with the mixture of PSA and C 18 . However, the ratio of sample (apple, rice, orange, and cabbage) matrix-matched standard-MIPs curve slope rate to the solvent standard curve was 1.05, 0.92, 1.09, and 1.05 in samples pretreated with MIPs, respectively. The results demonstrated that the matrices of the samples greatly interfered with the detection of parathion residues by CLEIA. The MIPs bound specifically to the parathion in the samples and eliminated the matrix interference effect. Therefore, the CLEIA method have successfully applied MIPs in sample pretreatment to eliminate matrix interference effects and provided a new sensitive assay for agro-products. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. A novel multi-hyphenated analytical method to simultaneously determine xanthine oxidase inhibitors and superoxide anion scavengers in natural products.

    PubMed

    Qi, Jin; Sun, Li-Qiong; Qian, Steven Y; Yu, Bo-Yang

    2017-09-01

    Natural products, such as rosmarinic acid and apigenin, can act as xanthine oxidase inhibitors (XOIs) as well as superoxide anion scavengers, and have potential for treatment of diseases associated with high uric acid levels and oxidative stress. However, efficient simultaneous screening of these two bioactivities in natural products has been challenging. We have developed a novel method by assembling a multi-hyphenated high performance liquid chromatography (HPLC) system that combines a photo-diode array, chemiluminescence detector and a HPLC system with a variable wavelength detector, to simultaneously detect components that act as both XOIs and superoxide anion scavengers in natural products. Superoxide anion scavenging activity in the analyte was measured by on-line chemiluminescence chromatography based on pyrogallol-luminol oxidation, while xanthine oxidase inhibitory activity was determined by semi-on-line HPLC analysis. After optimizing multiple elements, including chromatographic conditions (e.g., organic solvent concentration and mobile phase pH), concentrations of xanthine/xanthine oxidase and reaction temperature, our validated analytical method was capable of mixed sample analysis. The final results from our method are presented in an easily understood visual format including comprehensive bioactivity data of natural products. Copyright © 2017. Published by Elsevier B.V.

  1. Microfabricated Renewable Beads-Trapping/Releasing Flow Cell for Rapid Antigen-Antibody Reaction in Chemiluminescent Immunoassay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Zhifeng; Shao, Guocheng; Wang, Jun

    2011-04-01

    A filter pillar-array microstructure was coupled with a pneumatic micro-valve to fabricate a reusable miniaturized beads-trapping/releasing flow cell, in which trapping and releasing beads can be conveniently realized by switching the micro-valve. This miniaturized device was suitable to construct automatic fluidic system for “renewable surface analysis”. The renewable surface strategy based on pneumatic micro-valve enabled capture of beads in beads chamber prior to each assay, and release of the used beads after the assay. Chemiluminescent competitive immunoassay of 3,5,6-trichloropyridinol (TCP) was performed as a model to demonstrate the application potential of this reusable miniaturized flow cell. The whole fluidic assaymore » process including beads trapping, immuno-binding, beads washing, beads releasing and signal collection could be completed in 10 min. Immunoassay of TCP using this miniaturized device showed a linear range of 0.20-70 ng/mL with a limit of detection of 0.080 ng/mL. The device had been successfully used for detection of TCP spiked in rat serum with average recovery of 97%. This investigation provides a rapid, sensitive, reusable, low-cost and automatic miniaturized device for solid-phase biochemical analysis for various purposes.« less

  2. The effect of lipopolysaccharide (LPS) and phorbol 12-myristate 13-acetate (PMA) on whole blood oxidative response as assessed by luminol-amplified chemiluminescence in dairy cows

    USDA-ARS?s Scientific Manuscript database

    The differences between lipopolysaccharide (LPS) and phorbol 12-myristate 13-acetate (PMA) on whole blood oxidative response using luminol-amplified chemiluminescence (CL) are currently unknown in cattle. Luminol-dependent CL measures the amount of reactive oxygen species released from leukocytes a...

  3. Studies on water treeing and chemiluminescence on irradiated polyethylene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Notingher, P.V.; Ciuprina, F.; Radu, I.

    The effect of {gamma}-radiations on the growth kinetics of water trees is examined using the CNRS laboratory model in LDPE samples of different origins. The effect of radiations on the material is studied from crosslinking degree measurements, IRTF spectroscopy and chemiluminescence. Correlations between the non-uniformity of the degradation and the growth of water trees are observed.

  4. Egg-Citing! Isolation of Protoporphyrin IX from Brown Eggshells and Its Detection by Optical Spectroscopy and Chemiluminescence

    ERIC Educational Resources Information Center

    Dean, Michelle L.; Miller, Tyson A.; Bruckner, Christian

    2011-01-01

    A simple and cost-effective laboratory experiment is described that extracts protoporphyrin IX from brown eggshells. The porphyrin is characterized by UV-vis and fluorescence spectroscopy. A chemiluminescence reaction (peroxyoxalate ester fragmentation) is performed that emits light in the UV region. When the porphyrin extract is added as a fluor…

  5. Rapid and PCR-free DNA detection by nanoaggregation-enhanced chemiluminescence

    Treesearch

    Renu Singh; Alexandra Feltmeyer; Olga Saiapina; Jennifer Juzwik; Brett Arenz; Abdennour Abbas

    2017-01-01

    The aggregation of gold nanoparticles (AuNPs) is known to induce an enhancement of localized surface plasmon resonance due to the coupling of plasmonic fields of adjacent nanoparticles. Here we show that AuNPs aggregation also causes a significant enhancement of chemiluminescence in the presence of luminophores. The phenomenon is used to introduce a rapid and sensitive...

  6. An ultrasensitive chemiluminescence immunoassay for fumonisin B1 detection in cereals based on gold-coated magnetic nanoparticles.

    PubMed

    Jie, Mingsha; Yu, Songcheng; Yu, Fei; Liu, Lie; He, Leiliang; Li, Yanqiang; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B; Wu, Yongjun

    2018-07-01

    In the present study, a novel highly sensitive magnetic enzyme chemiluminescence immunoassay (MECLIA) was developed to detect fumonisin B 1 (FB 1 ) in cereal samples. The gold-coated magnetic nanoparticles (Fe 3 O 4 @Au, GoldMag) were used as solid phase carrier to develop a competitive CLIA for detecting FB 1 , in which FB 1 in samples would compete with FB 1 -ovalbumin coated on the surface of Fe 3 O 4 @Au nanoparticles for binding with FB 1 antibodies. Successively, horseradish peroxidase labeled goat anti-rabbit IgG (HRP-IgG) was conjugated with FB 1 antibodies on the microplate. In substrate solution containing luminol and H 2 O 2 , HRP-IgG catalyzed luminol oxidation by H 2 O 2 , generating a high chemiluminescence signal. The FB 1 immune GoldMag particles were characterized by Fourier transform infrared spectroscopy, scanning electron microscope and zeta potential analysis, etc. RESULTS: The concentrations and the reaction times of these immunoreagents were optimized to improve the performances of this method. The established method could detect as low as 0.027 ng mL -1 FB 1 from 0.05 ng mL -1 to 25 ng mL -1 , demonstrating little cross-reaction (less than 2.4%) with other structurally related compounds. The average intrassay relative SD (RSD) (n = 6) was 3.4% and the average interassay RSD (n = 6) was 5.4%. This method was successfully applied for the determination of FB 1 in corn and wheat and gave recoveries of between 98-110% and 91-105%, respectively. The results of the present study suggest that the MECLIA approach has potential application for high-throughput fumonisin screening in cereals. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  7. Chemiluminescence of creatinine/H2O2/Co(2+) and its application for selective creatinine detection.

    PubMed

    Hanif, Saima; John, Peter; Gao, Wenyue; Saqib, Muhammad; Qi, Liming; Xu, Guobao

    2016-01-15

    Creatinine is an important biomarker in clinical diagnosis and biomonitoring programs as well as urinary metabolomic/metabonomics research. Current methods are either nonselective, time consuming or require heavy and expensive instruments. In this study, chemiluminescence of creatinine with hydrogen peroxide has been reported for the first time, and its chemiluminescence is remarkably enhanced in the presence of cobalt ions. By utilizing these phenomena, we have developed a sensitive and selective chemiluminescence method for creatinine determination by coupling with flow injection analysis. The calibration curve is linear in the range of 1×10(-7)-3×10(-5)mol/L with a limit of detection (S/N=3) of 7.2×10(-8)mol/L, which is adequate for detecting creatinine in the clinically accepted range. The relative standard deviation for seven measurements of 3×10(-5)mol/L creatinine is 1.2%. The chemiluminescence method was then utilized to detect creatinine in human urine samples after simple dilution with water. It takes less than 1min each measurement and the recoveries for spiked urine samples were 100-103%. The interference study demonstrates that some common species in urine, such as amino acids, ascorbic acid and creatine, have negligible effects on creatinine detection. The present method does not use expensive instruments, enzymes and separation technique. This method has the advantages of sensitivity, selectivity, simplicity, rapidity, and low cost. It holds great promise for basic or comprehensive metabolic panel, drug screening, anti-dopping, and urinary metabolomic/metabonomics research. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Electrochemical luminescence determination of hyperin using a sol-gel@graphene luminescent composite film modified electrode for solid phase microextraction

    NASA Astrophysics Data System (ADS)

    Zou, Xiaojun; Shang, Fang; Wang, Sui

    2017-02-01

    In this paper, a novel electrochemiluminescence (ECL) sensor of sol-gel@graphene luminescent composite film modified electrode for hyperin determination was prepared using graphene (G) as solid-phase microextraction (SPME) material, based on selective preconcentration of target onto an electrode and followed by luminol ECL detection. Hyperin was firstly extracted from aqueous solution through the modified GCE. Hydrogel, electrogenerated chemiluminescence reagents, pH of working solution, extraction time and temperature and scan rate were discussed. Under the optimum conditions, the change of ECL intensity was in proportion to the concentration of hyperin in the range of 0.02-0.24 μg/mL with a detection limit of 0.01 μg/mL. This method showed good performance in stability, reproducibility and precision for the determination of hyperin.

  9. First ozone profiles measured with electrochemical and chemiluminescent sondes, developed in Russia

    NASA Technical Reports Server (NTRS)

    Zuyaguintsev, Anatoly M.; Perov, Stanislav P.; Ryabov, Youry A.

    1994-01-01

    Results obtained with experimental balloon electrochemical and chemiluminescent ozonesondes are summarized and estimated as quite satisfactory. The average normalization factor for the electrochemical ozonesonde obtained in 1991 at four Soviet balloon routine network stations is 1.069+.073 (in 17 flights). Some ozone profiles obtained in summer 1991 at Volgograd are discussed together with corresponding meteorological data.

  10. Ultrafine particles and nitrogen oxides generated by gas and electric cooking.

    PubMed

    Dennekamp, M; Howarth, S; Dick, C A; Cherrie, J W; Donaldson, K; Seaton, A

    2001-08-01

    To measure the concentrations of particles less than 100 nm diameter and of oxides of nitrogen generated by cooking with gas and electricity, to comment on possible hazards to health in poorly ventilated kitchens. Experiments with gas and electric rings, grills, and ovens were used to compare different cooking procedures. Nitrogen oxides (NO(x)) were measured by a chemiluminescent ML9841A NO(x) analyser. A TSI 3934 scanning mobility particle sizer was used to measure average number concentration and size distribution of aerosols in the size range 10-500 nm. High concentrations of particles are generated by gas combustion, by frying, and by cooking of fatty foods. Electric rings and grills may also generate particles from their surfaces. In experiments where gas burning was the most important source of particles, most particles were in the size range 15-40 nm. When bacon was fried on the gas or electric rings the particles were of larger diameter, in the size range 50-100 nm. The smaller particles generated during experiments grew in size with time because of coagulation. Substantial concentrations of NO(X) were generated during cooking on gas; four rings for 15 minutes produced 5 minute peaks of about 1000 ppb nitrogen dioxide and about 2000 ppb nitric oxide. Cooking in a poorly ventilated kitchen may give rise to potentially toxic concentrations of numbers of particles. Very high concentrations of oxides of nitrogen may also be generated by gas cooking, and with no extraction and poor ventilation, may reach concentrations at which adverse health effects may be expected. Although respiratory effects of exposure to NO(x) might be anticipated, recent epidemiology suggests that cardiac effects cannot be excluded, and further investigation of this is desirable.

  11. Cultured astrocytes do not release adenosine during hypoxic conditions

    PubMed Central

    Fujita, Takumi; Williams, Erika K; Jensen, Tina K; Smith, Nathan A; Takano, Takahiro; Tieu, Kim; Nedergaard, Maiken

    2012-01-01

    Recent reports based on a chemiluminescent enzymatic assay for detection of adenosine conclude that cultured astrocytes release adenosine during mildly hypoxic conditions. If so, astrocytes may suppress neural activity in early stages of hypoxia. The aim of this study was to reevaluate the observation using high-performance liquid chromatography (HPLC). The HPLC analysis showed that exposure to 20 or 120 minutes of mild hypoxia failed to increase release of adenosine triphosphate (ATP), adenosine diphosphate (ADP), adenosine monophosphate (AMP), and adenosine from cultured astrocytes. Similar results were obtained using a chemiluminescent enzymatic assay. Moreover, since the chemiluminescent enzymatic assay relies on hydrogen peroxide generation, release of free-radical scavengers from hypoxic cells can interfere with the assay. Accordingly, adenosine added to samples collected from hypoxic cultures could not be detected using the chemiluminescent enzymatic assay. Furthermore, addition of free-radical scavengers sharply reduced the sensitivity of adenosine detection. Conversely, use of a single-step assay inflated measured values due to the inability of the assay to distinguish adenosine and its metabolite inosine. These results show that cultured astrocytes do not release adenosine during mild hypoxia, an observation consistent with their high resistance to hypoxia. PMID:21989480

  12. Video approach to chemiluminescence detection using a low-cost complementary metal oxide semiconductor (CMOS)-based camera: determination of paracetamol in pharmaceutical formulations.

    PubMed

    Lahuerta-Zamora, Luis; Mellado-Romero, Ana M

    2017-06-01

    A new system for continuous flow chemiluminescence detection, based on the use of a simple and low-priced lens-free digital camera (with complementary metal oxide semiconductor technology) as a detector, is proposed for the quantitative determination of paracetamol in commercial pharmaceutical formulations. Through the camera software, AVI video files of the chemiluminescence emission are captured and then, using friendly ImageJ public domain software (from National Institutes for Health), properly processed in order to extract the analytical information. The calibration graph was found to be linear over the range 0.01-0.10 mg L -1 and over the range 1.0-100.0 mg L -1 of paracetamol, the limit of detection being 10 μg L -1 . No significative interferences were found. Paracetamol was determined in three different pharmaceutical formulations: Termalgin®, Efferalgan® and Gelocatil®. The obtained results compared well with those declared on the formulation label and with those obtained through the official analytical method of British Pharmacopoeia. Graphical abstract Abbreviated scheme of the new chemiluminescence detection system proposed in this paper.

  13. A simple and sensitive immunoassay for the determination of human chorionic gonadotropin by graphene-based chemiluminescence resonance energy transfer.

    PubMed

    Lei, Jiuqian; Jing, Tao; Zhou, Tingting; Zhou, Yusun; Wu, Wei; Mei, Surong; Zhou, Yikai

    2014-04-15

    In this study, we report a strategy of chemiluminescence resonance energy transfer (CRET) using graphene as an efficient long-range energy acceptor. Magnetic nanoparticles were also used in CRET for simple magnetic separation and immobilization of horseradish peroxidase (HRP)-labeled anti-HCG antibody. In the design of CRET system, the sandwich-type immunocomplex was formed between human chorionic gonadotropin (HCG, antigen) and two different antibodies bridged the magnetic nanoparticles and graphene (acceptors), which led to the occurrence of CRET from chemiluminescence light source to graphene. After optimizing the experimental conditions, the quenching of chemiluminescence signal depended linearly on the concentration of HCG in the range of 0.1 mIU mL(-1)-10 mIU mL(-1) and the detection limit was 0.06 mIU mL(-1). The proposed method was successfully applied for the determination of HCG levels in saliva and serum samples, and the results were in good agreement with the plate ELISA with colorimetric detection. It could also be developed for detection of other antigen-antibody immune complexes by using the corresponding antigens and respective antibodies. © 2013 Published by Elsevier B.V.

  14. Chemiluminescence measurements on irradiated garlic powder by the single photon counting technique

    NASA Astrophysics Data System (ADS)

    Narvaiz, P.

    1995-02-01

    The feasibility of identifying irradiated garlic powder measuring chemiluminescence by liquid scintillation spectrometry was studied. Samples packed in 100 μm thick polyethylene bags were irradiated in a 60Co semi-industrial facility, with doses of 10 and 30 kGy. Control and irradiated samples were stored at 20 ± 4°C and 70 ± 10% RH in darkness for 2 years. Assays were performed to establish the best sample concentration and pH of the buffer solution in which garlic powder was to be suspended for its measurement. The water content of garlic samples was also analyzed throughout storage time, as it related to the stability of the species causing luminescence. Chemiluminescence values diminished in every sample over storage time following an exponential pattern. Irradiated samples showed values significantly higher than those of the control samples, according to the radiation dose, throughout the storage period. This does not necessarily imply that the identification of the irradiated samples would be certain, since values of control samples coming from different origins have been found to fluctuate within a rather wide range. Nonetheless, in principle, the method looks promising for the measurement of chemiluminescence in irradiated samples

  15. Chemiluminescence evidence supporting the selective role of ligands in the permanganate oxidation of micropollutants.

    PubMed

    Roderick, Mark S; Adcock, Jacqui L; Terry, Jessica M; Smith, Zoe M; Parry, Samuel; Linton, Stuart M; Thornton, Megan T; Barrow, Colin J; Francis, Paul S

    2013-10-10

    The selective increase in the oxidation rate of certain organic compounds with permanganate in the presence of environmental "ligands" and reduced species has been ascribed to the different reactivity of the target compounds toward Mn(III), which bears striking similarities to recent independent investigations into the use of permanganate as a chemiluminescence reagent. In spite of the importance of Mn(III) in the light-producing pathway, the dependence of the oxidation mechanism for any given compound on this intermediate could not be determined solely through the emission intensity. However, target compounds susceptible to single-electron oxidation by Mn(III) (such as bisphenol A and triclosan) can be easily distinguished by the dramatic increase in chemiluminescence intensity when a permanganate reagent containing high, stable concentrations of Mn(III) is used. The differences are accentuated under the low pH conditions that favor the chemiluminescence emission due to the greater reactivity of Mn(III) and the greater influence of complexing agents. This study supports the previously postulated selective role of ligands and reducing agents in permanganate oxidations and demonstrates a new approach to explore the chemistry of environmental manganese redox processes.

  16. Effect of bacterial stimulants on release of reactive oxygen metabolites from peripheral blood neutrophils in periodontitis.

    PubMed

    Zekonis, Gediminas; Zekonis, Jonas

    2004-01-01

    The aim of the present investigation was to explore the oxidative activity of peripheral blood polymorphonuclear neutrophils of periodontitis patients and of healthy subjects stimulated with non-opsonized E. coli and lipopolysaccharide of E. coli. The leukocytes for this study were obtained from peripheral venous blood of 22 parodontitis patients and 16 healthy subjects. Oxidative activity of peripheral blood polymorphonuclear neutrophils was measured by method of the luminol-dependent chemiluminescence. The luminol-dependent chemiluminescence of stimulated neutrophils of periodontitis patients with non-opsonized E. coli increased less significantly (p<0.001) as compared to analogous chemiluminescence of control subjects (147126+/-8386 cpm and 189247+/-9134 cpm, respectively). However, the luminol-dependent chemiluminescence of stimulated neutrophils of periodontitis patients with lipopolysaccharide was five times higher than that of the subjects with intact periodontal tissues and comprised 13261+/-1251 cpm and 2627+/-638 cpm, respectively. Our study results show a complex dependence of oxidative function of peripheral polymorphonuclear neutrophils of periodontitis patients upon the nature of stimulants. Therefore further attempts should be made to evaluate its significance in the etiopathogenesis of periodontal tissue diseases of inflammatory origin.

  17. Opsonic antibody activity against Actinobacillus actinomycetemcomitans in patients with rapidly progressive periodontitis.

    PubMed Central

    Sjöström, K; Darveau, R; Page, R; Whitney, C; Engel, D

    1992-01-01

    Actinobacillus actinomycetemcomitans has been closely associated with early-onset, severe periodontitis, and such patients often have serum immunoglobulin G (IgG) antibodies reactive with antigens of this gram-negative pathogen. We examined the functionality and potential importance of these antibodies. The opsonic activity against A. actinomycetemcomitans of sera from 30 patients with rapidly progressive periodontitis (RPP) and from 28 periodontally normal subjects was tested by using polymorphonuclear leukocyte (PMN) chemiluminescence and bactericidal assays. Peak chemiluminescence values correlated strongly with killing observed in the PMN-dependent bactericidal assay (r = 0.88; P < 0.001). Neither the mean IgG titer nor the mean peak chemiluminescence differed significantly between the two groups. However, when the relationship between chemiluminescence and titer was examined, regression analysis showed that antibodies present in low-titer normal sera were significantly more effective at opsonizing A. actinomycetemcomitans than antibodies present in low-titer RPP patient sera (P = 0.04). Thus, periodontally normal individuals may be better able than RPP patients to clear A. actinomycetemcomitans in early stages of colonization, and anti-A. actinomycetemcomitans antibodies in RPP patients may be relatively ineffective in preventing infection by this organism. PMID:1398993

  18. Experimental study of a staged combustion system for stationary gas turbine applications

    NASA Astrophysics Data System (ADS)

    Lamont, Warren G.

    Two optically accessible experimental test rigs were designed and constructed to investigate a staged or distributed combustion system for stationary gas turbine applications. The test rigs were fuelled with natural gas and featured two combustion zones: the main combustion zone (MCZ) and the secondary combustion zone (SCZ). The MCZ is a swirl stabilized dump combustor and the SCZ, which is axially downstream from the MCZ, is formed by a transverse jet injecting a premixed fuel/air mixture into the vitiated stream. After installing and commissioning the test rig, an emission survey was conducted to investigate the SCZ conditions, equivalence ratio and momentum ratio, that produce low NOx emissions and give a higher temperature rise before a simulated high pressure turbine than firing only the MCZ. The emission survey found several operating conditions that show the benefit of combustion staging. These beneficial conditions had an SCZ equivalence ratio between 0.41 and 1.12. The data from the emission survey was then used to create an artificial neural network (ANN). The ANN used a multi-layer feed-forward network architecture and was trained with experimental data using the backpropagation training algorithm. The ANN was then used to create performance maps and optimum operational regions were sought. Lastly, optical diagnostics were used to obtain information on the nature of the SCZ reactive jet. The diagnostics included high speed CH* chemiluminescence, OH planar laser induced fluorescence (PLIF) and dual-pump coherent anti-Stokes Raman scattering (CARS). The chemiluminescence and PLIF were used to qualitatively determine the size and shape of the transverse jet reaction zone. Dual-pump CARS was used to quantitatively determine the temperature and H2/N2 concentration ratio profile at the mid-plane of the transverse jet. Dual-pump CARS data was collected for four operating conditions but only one is presented in this dissertation. For the condition presented, the temperature ranged from 1200 K to 2500 K, and regions with the highest temperature also corresponded to regions with the most temperature fluctuation, indicating the presence of a reactive shear layer. The concentration ratio of H2/N2 ranged from 6.4×-3 to 4.8×10-2. Regions of high temperature also correspond to high H2/N2 concentration ratios indicating the location of the primary reaction zone.

  19. Investigation of the characteristics and stability of air-staged flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ballester, J.; Sanz, A.; Gonzalez, M.A.

    The influence of burner aerodynamics on the characteristics of the flame has been studied by means of detailed measurements in a laboratory gas-fired furnace. The distribution of air between two concentric injections and the swirl numbers of both air streams were systematically varied. As a result, a broad range of flames were obtained. The spatial distribution of temperature and species revealed important differences in the configuration of the flame, for which plausible interpretations are proposed. Air-staged flames led to reductions in NO{sub x} emissions down to one third. The fluctuations in pressure and heat release (estimated from OH* chemiluminescence) weremore » characterised in detail. Their standard deviations varied widely with the burner settings, reaching the highest values in some regimes close to flame extinction and also for high staging ratios. Analysis in the frequency domain revealed some characteristic peaks in the pressure spectra, some of them associated with resonant modes of the combustion chamber and the burner. Cross-correlations between the pressure and chemiluminescence signals indicated the onset of thermo-acoustic instabilities for highly air-staged flames, but not for non-staged regimes. This is attributed to the partial premixing achieved before the second combustion stage. The results confirm that the Rayleigh index is related to the magnitude of the fluctuations but, for the cases explored, the threshold associated with the onset of thermo-acoustic coupling might be different depending on the degree of premixing. (author)« less

  20. An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Davis, Douglas D.; Beltz, Nobert; Bandy, Alan R.; Ferek, Ronald J.; Thornton, Donald C.

    1993-01-01

    As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.

  1. Simultaneous identification and quantification of new psychoactive substances in blood by GC-APCI-QTOFMS coupled to nitrogen chemiluminescence detection without authentic reference standards.

    PubMed

    Ojanperä, Ilkka; Mesihää, Samuel; Rasanen, Ilpo; Pelander, Anna; Ketola, Raimo A

    2016-05-01

    A novel platform is introduced for simultaneous identification and quantification of new psychoactive substances (NPS) in blood matrix, without the necessity of using authentic reference standards. The instrumentation consisted of gas chromatography (GC) coupled to nitrogen chemiluminescence detection (NCD) and atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry (APCI-QTOFMS). In this concept, the GC flow is divided in appropriate proportions between NCD for single-calibrant quantification, utilizing the detector's equimolar response to nitrogen, and QTOFMS for accurate mass-based identification. The principle was proven by analyzing five NPS, bupropion, desoxypipradrol (2-DPMP), mephedrone, methylone, and naphyrone, in sheep blood. The samples were spiked with the analytes post-extraction to avoid recovery considerations at this point. All the NPS studies produced a protonated molecule in APCI resulting in predictable fragmentation with high mass accuracy. The N-equimolarity of quantification by NCD was investigated by using external calibration with the secondary standard caffeine at five concentration levels between 0.17 and 1.7 mg/L in blood matrix as five replicates. The equimolarity was on average 98.7%, and the range of individual equimolarity determinations was 76.7-130.1%. The current analysis platform affords a promising approach to instant simultaneous qualitative and quantitative analysis of drugs in the absence of authentic reference standards, not only in forensic and clinical toxicology but also in other bioanalytical applications.

  2. Nitric Oxide Analyzer Quantification of Plant S-Nitrosothiols.

    PubMed

    Hussain, Adil; Yun, Byung-Wook; Loake, Gary J

    2018-01-01

    Nitric oxide (NO) is a small diatomic molecule that regulates multiple physiological processes in animals, plants, and microorganisms. In animals, it is involved in vasodilation and neurotransmission and is present in exhaled breath. In plants, it regulates both plant immune function and numerous developmental programs. The high reactivity and short half-life of NO and cross-reactivity of its various derivatives make its quantification difficult. Different methods based on calorimetric, fluorometric, and chemiluminescent detection of NO and its derivatives are available, but all of them have significant limitations. Here we describe a method for the chemiluminescence-based quantification of NO using ozone-chemiluminescence technology in plants. This approach provides a sensitive, robust, and flexible approach for determining the levels of NO and its signaling products, protein S-nitrosothiols.

  3. Low-Temperature Chemiluminescence From cis-1,4-Polybutadiene, 1,2-Polybutadiene, and trans-Polypentenamer at Temperatures Near Ambient

    NASA Technical Reports Server (NTRS)

    Nathan, Richard A.; Mendenhall, G. David; Birts, Michelle A.; Ogle, Craig A.; Golub, Morton A.

    1978-01-01

    The chemiluminescence emission at 25-60 C was measured from films of cis-1,4-polybutadiene, 1,2-polybutadiene, and trans-polypentenamer. The polymers were autoxidized previously in air 100 C, or allowed to react with singlet molecular oxygen in solution, and then cast into films. Values of beta(or k(sub d,((1)O2 yields (3)03)/k(sub r)((1)O2 + polymer yields products)) were determined in benzene for cis-1,4-polybutadiene and cis-1,4-polyisoprene, and for model compounds cis-3-hexene and cis-3-methyl-3-hexene by independent methods. The chemiluminescence emission from irradiated films of the polymers containing a dye sensitizer showed a complicated time dependence, and the results depended on the length of irradiation.

  4. Chemiluminescent activation of the antiviral activity of hypericin: a molecular flashlight.

    PubMed Central

    Carpenter, S; Fehr, M J; Kraus, G A; Petrich, J W

    1994-01-01

    Hypericin is a naturally occurring photosensitizer that displays potent antiviral activity in the presence of light. The absence of light in many regions of the body may preclude the use of hypericin and other photosensitizers as therapeutic compounds for the treatment of viral infections in vivo. The chemiluminescent oxidation of luciferin by the luciferase from the North American firefly Photinus pyralis was found to generate sufficiently intense and long-lived emission to induce antiviral activity of hypericin. Light-induced virucidal activity of hypericin was demonstrated against equine infectious anemia virus, a lentivirus structurally, genetically, and antigenically related to the human immunodeficiency virus. The implications for exploiting chemiluminescence as a "molecular flashlight" for effecting photodynamic therapy against virus-infected cells and tumor cells are discussed. PMID:7991618

  5. Recent assessment of the performance and accuracy of a chemiluminescent rocket sonde for upper atmospheric ozone measurements

    NASA Technical Reports Server (NTRS)

    Hilsenrath, E.; Kirschner, P. T.

    1980-01-01

    The chemiluminescent rocket ozonesonde utilizing rhodamine-B as a detector and self-pumping for air sampling has been improved. The instrument employs standard meteorological sounding systems and is the only technique available for routine nighttime ozone measurements above balloon altitudes. The chemiluminescent detector, when properly calibrated, is shown to be specific to ozone, stable, and of sufficient sensitivity for accurate measurements of ozone from about 65-20 km. An error analysis indicates that the measured ozone profiles have an absolute accuracy of about + or - 12% and a precision of about + or - 6%. Approximately 20 flights have been conducted for geophysical investigations, while additional flights were conducted with other rocket and satellite ozone soundings for comparisons. In general, these comparisons showed good agreement.

  6. Flow injection chemiluminescence determination of 6-mercaptopurine based on a new system of potassium permanganate-thioacetamide-sodium hexametaphosphate.

    PubMed

    Wang, Lun; Ling, Bo; Chen, Hongqi; Liang, Ani; Qian, Binbin; Fu, Jie

    2010-01-01

    A novel chemiluminescence method for the determination of 6-mercaptopurine was established based on 6-mercaptopurine inhibition of the chemiluminescence emission of potassium permanganate-thioacetamide-sodium hexametaphosphate system. The peak height was proportional to log 6-mercaptopurine concentration in the range 7.0 × 10(-10) to 1.0 × 10(-7)  g/mL and the detection limit was 1.9 × 10(-11)  g/mL (S/N = 3). The relative standard deviation was 1.5% for the determination of 8.0 × 10(-8)  g/mL 6-mercaptopurine (n = 11). The proposed sensor was successfully applied to the analysis of 6-mercaptopurine in human serum samples. Copyright © 2009 John Wiley & Sons, Ltd.

  7. Chemiluminescent Nanomicelles for Imaging Hydrogen Peroxide and Self-Therapy in Photodynamic Therapy

    PubMed Central

    Chen, Rui; Zhang, Luzhong; Gao, Jian; Wu, Wei; Hu, Yong; Jiang, Xiqun

    2011-01-01

    Hydrogen peroxide is a signal molecule of the tumor, and its overproduction makes a higher concentration in tumor tissue compared to normal tissue. Based on the fact that peroxalates can make chemiluminescence with a high efficiency in the presence of hydrogen peroxide, we developed nanomicelles composed of peroxalate ester oligomers and fluorescent dyes, called peroxalate nanomicelles (POMs), which could image hydrogen peroxide with high sensitivity and stability. The potential application of the POMs in photodynamic therapy (PDT) for cancer was also investigated. It was found that the PDT-drug-loaded POMs were sensitive to hydrogen peroxide, and the PDT drug could be stimulated by the chemiluminescence from the reaction between POMs and hydrogen peroxide, which carried on a self-therapy of the tumor without the additional laser light resource. PMID:21765637

  8. Encapsulation of Hemin in Metal-Organic Frameworks for Catalyzing the Chemiluminescence Reaction of the H2O2-Luminol System and Detecting Glucose in the Neutral Condition.

    PubMed

    Luo, Fenqiang; Lin, Yaolin; Zheng, Liyan; Lin, Xiaomei; Chi, Yuwu

    2015-06-03

    Novel metal-organic frameworks (MOFs) based solid catalysts have been synthesized by encapsulating Hemin into the HKUST-1 MOF materials. These have been first applied in the chemiluminescence field with outstanding performance. The functionalized MOFs not only maintain an excellent catalytic activity inheriting from Hemin but also can be cyclically utilized as solid mimic peroxidases in the neutral condition. The synthesized Hemin@HKUST-1 composites have been used to develop practical sensors for H2O2 and glucose with wide response ranges and low detection limits. It was envisioned that catalyst-functionalized MOFs for chemiluminescence sensing would have promising applications in green, selective, and sensitive detection of target analytes in the future.

  9. Hydrazine-induced post-chemiluminescence phenomenon of permanganate-luminol reaction and its applications.

    PubMed

    Du, Jianxiu; Lu, Jiuru

    2004-01-01

    The post-chemiluminescence phenomenon arising from the permanganate-luminol reaction induced by hydrazine and isoniazid was investigated. When hydrazine or isoniazid was injected into the mixture after the end of the reaction of permanganate with alkaline luminol, a new chemiluminescence (CL) reaction was initiated and strong CL signal was detected. A possible CL mechanism is suggested, based upon the studies of the kinetic characteristics of the CL reaction, the UV-visible spectra, the CL spectra and some other experiments. The present reactions allow the determination of 0.1-10.0 mg/L hydrazine and 0.02-1.0 mg/L isoniazid, with detection limits of 0.03 mg/L and 0.006 mg/L, respectively. The method was applied to the determination of isoniazid in pharmaceutical preparations.

  10. Chemiluminescence of neutrophils from patients with Behçet's disease and its correlation with an increased proportion of uncommon serotypes of Streptococcus sanguis in the oral flora.

    PubMed

    Isogai, E; Ohno, S; Kotake, S; Isogai, H; Tsurumizu, T; Fujii, N; Yokota, K; Syuto, B; Yamaguchi, M; Matsuda, H

    1990-01-01

    Zymosan-induced chemiluminescence was investigated in whole blood and in neutrophils: in both, the peak count was frequently elevated in Behçet's disease, and was significantly higher than in healthy controls; similarly the peak time was shorter. There were more uncommon serotypes of Streptococcus sanguis in the oral flora of patients with Behçet's disease. Common serotypes were present in the flora of healthy controls, but not in patients with the disease. The percentage of Strep. sanguis in the oral flora was significantly correlated with the level of chemiluminescence response. Thus infection with uncommon serotypes of Strep. sanguis may play a role in the aetiology of Behçet's disease.

  11. Investigation of the impact of imposed air inlet velocity oscillations on the formation and oxidation of soot using simultaneous 2-Colour-TIRE-LII

    NASA Astrophysics Data System (ADS)

    Aleksandrov, A.; Suntz, R.; Bockhorn, H.

    2015-05-01

    The response of non-premixed swirling flames to acoustic perturbations at various frequencies (0-350 Hz) and the impact of imposed air inlet velocity oscillations on the formation and oxidation of soot are investigated. The results obtained from these flames are of special interest for "rich-quenched-lean" (RQL) combustion concepts applied in modern gas turbines. In RQL combustion, the fuel is initially oxidized by air under fuel-rich conditions in a first stage followed by a fuel-lean combustion step in a second stage. To mimic soot formation and oxidation in RQL combustion, soot particle measurements in highly turbulent, non-premixed swirling natural gas/ethylene-confined flames at imposed air inlet velocity oscillations are performed using simultaneous 2-Colour-Time-Resolved-Laser-Induced Incandescence (simultaneous 2-Colour-TIRE-LII). The latter technique is combined with line-of-sight averaged OH*-chemiluminescence imaging, measurements of the velocity field by high-speed particle imaging velocimetry under reactive combustion conditions and measurements of the mean temperature field obtained by a thermocouple. A natural gas/ethylene mixture (Φ = 1.56, 42 % C2H4, 58 % natural gas, P th = 17.6 kW at atmospheric pressure) is used as a fuel, which is oxidized by air under fuel-rich conditions in the first combustion chamber.

  12. Infrared chemiluminescence study of the reaction Cl + HI yielding HCl + I at enhanced collision energies.

    NASA Technical Reports Server (NTRS)

    Cowley, L. T.; Horne, D. S.; Polanyi, J. C.

    1971-01-01

    Performed chemiluminescence and beam experiments show a markedly increased efficiency of conversion of the reaction energy into vibration and a markedly enhanced tendency for forward scattering in the reaction Cl + HI yields HCl + I as compared with H + Cl2 yields HCl + Cl. These differences appear to be due predominantly to the difference in the masses involved.

  13. Portable Chemical Agent Detection System: Differential Reflectometer and Light Scattering Approaches

    DTIC Science & Technology

    2005-02-15

    possible to conduct elemental analysis on modified capillaries because of the polymer coating. Instead, measurements of electroosmotic flow were used...design There are several essential requirements for a sensitive chemiluminescence cell (Figure 1); good reagent/analyte mixing for maximum photon yield...Cutaway of Chemiluminescence cell the cooled pint housing. In our design, the concentric inlets will increase photon collection due to better mixing of

  14. Chemiluminescent optical fiber immunosensor for the detection of anti-West Nile virus IgG.

    PubMed

    Herrmann, Sebastien; Leshem, Boaz; Landes, Shimi; Rager-Zisman, Bracha; Marks, Robert S

    2005-03-31

    An ELISA-based optical fiber methodology developed for the detection of anti-West Nile virus IgG antibodies in serum was compared to standard colorimetric and chemiluminescent ELISA based on microtiter plates. Colorimetric ELISA was the least sensitive, especially at high titer dilutions. The fiber-optic immunosensor based on the same ELISA immunological rationale was the most sensitive technique.

  15. Mononuclear leucocyte function tests in the assessment of the biocompatibility of peritoneal dialysis fluids.

    PubMed

    Brulez, H F; ter Wee, P M; Snijders, S V; Donker, A J; Verbrugh, H A

    1999-12-01

    Previous studies showed that the currently used dextrose based peritoneal dialysis fluids impair several leucocyte functions. To determine which in vitro mononuclear leucocyte (monocyte) function tests most clearly reflect the biocompatibility of peritoneal dialysis fluid. Monocytes were tested for phagocytic capacity, bactericidal activity, Fc and C3 receptor expression, and chemiluminescence response, and by analysis of the release of interleukin 8 (IL-8) and tumour necrosis factor alpha (TNF alpha) in the presence of test fluids. Cytokine release was studied in an alternative dynamic in vitro peritoneal dialysis model in which monocytes were exposed to test fluid that was continuously equilibrated with an interstitial fluid-like medium through a microporous membrane. The chemiluminescence response by stressed monocytes was also tested after an 18 h recovery period. All tests were performed during or after exposure to different degrees of glycerol induced osmotic stress and after exposure to a 1% milk-whey derived, polypeptide enriched test fluid. Cells incubated in 0.1% gel Hanks buffer (GH) served as control. Osmotic stress induced impairment of leucocyte function was found by the chemiluminescence assay (mean (SEM): 179 (20)% v 138 (23)% after 30 minutes in 0.5% and 1.5% glycerol, respectively) and by the analysis of IL-8 released by monocytes (44 (9) ng in 0.7% glycerol v 40 (7) ng in 2.0% glycerol). Only the chemiluminescence assay showed a protective effect of polypeptides on leucocyte function (after > or = 60 minutes). If monocytes were allowed to recover in culture medium after exposure to test fluids, the changes in chemiluminescence response appeared to be reversible after a 30 minute exposure, but became more pronounced after 60 and 120 minutes. The phagocytosis and bacterial killing assays were less sensitive. The observations carried out with the phagocytosis assay did not correspond with the Fc or C3 receptor density data. The release of IL-8 by peripheral blood monocytes in a two compartment model and their chemiluminescence response are appropriate assays for the assessment of changes in leucocyte function in response to different peritoneal dialysis fluids.

  16. Rapid and simple G-quadruplex DNA aptasensor with guanine chemiluminescence detection.

    PubMed

    Cho, Sandy; Park, Lucienne; Chong, Richard; Kim, Young Teck; Lee, Ji Hoon

    2014-02-15

    Cost-effective and sensitive aptasensor with guanine chemiluminescence detection capable of simply quantifying thrombin in human serum was developed using thrombin aptamer (TBA), one of the G-quadruplex DNA aptamers, without expensive nanoparticles and complicated procedures. Guanines of G-quadruplex TBA-conjugated carboxyfluorescein (6-FAM) bound with thrombin do not react with 3,4,5-trimethoxylphenylglyoxal (TMPG) in the presence of tetra-n-propylammonium hydroxide (TPA), whereas guanines of free TBA- and TBA-conjugated 6-FAM immobilized on the surface of graphene oxide rapidly react with TMPG to emit light. Thus, guanine chemiluminescence in 5% human serum with thrombin was lower than that without thrombin when TBA-conjugated 6-FAM was added in two samples and incubated for 20 min. In other words, the brightness of guanine chemiluminescence was quenched due to the formation of G-quadruplex TBA-conjugated 6-FAM bound with thrombin in a sample. High-energy intermediate, capable of emitting dim light by itself, formed from the reaction between guanines of TBA and TMPG in the presence of TPA, transfers energy to 6-FAM to emit bright light based on the principle of chemiluminescence energy transfer (CRET). G-quadruplex TBA aptasensor devised using the rapid interaction between TBA-conjugated 6-FAM and thrombin quantified trace levels of thrombin without complicated procedures. The limit of detection (LOD = background + 3 × standard deviation) of G-quadruplex TBA aptasensor with good linear calibration curve, accuracy, precision, and recovery was as low as 12.3 nM in 5% human serum. Using the technology reported in this research, we expect that various types of G-quadruplex DNA aptasensors capable of specifically sensing a target molecule such as ATP, HIV, ochratoxin, potassium ions, and thrombin can be developed. © 2013 Elsevier B.V. All rights reserved.

  17. Detection of gamma irradiated pepper and papain by chemiluminescence

    NASA Astrophysics Data System (ADS)

    Sattar, Abdus; Delincée, H.; Diehl, J. F.

    Chemiluminescence (CL) measurements of black pepper and of papain using luminol and lucigenin reactions were studied. Effects of grinding, irradiation (5-20 kGy) and particle size (750-140 μm) on CL of pepper, and of irradiation (10-30 kGy) on CL of papain, were investigated. All the tested treatments affected the luminescence response in both the luminol and lucigenin reactions; however, the pattern of changes in each case, was inconsistent. Optimum pepper size for maximum luminescence was 560 μm, and optimum irradiation doses were >15 kGy for pepper and >20 kGy for papain. Chemiluminescence may possibly be used as an indicator or irradiation treatment for pepper and papain at a dose of 10 kGy or higher, but further research is needed to establish the reliability of this method.

  18. Fluorescence and chemiluminescence behavior of distyrylbenzene bearing two arms of dipicolylaminomethyl groups: Interactions with zinc ion and ATP

    NASA Astrophysics Data System (ADS)

    Motoyoshiya, Jiro; Wada, Jun-ya; Itoh, Keiko; Wakabayashi, Kazuaki; Maruyama, Takayuki; Ono, Kazuki; Fukasawa, Kota; Fujimoto, Tetsuya; Akaiwa, Yuji; Nonaka, Eiji

    2018-04-01

    The absorption and fluorescence spectral study of the distyrylbenzene bearing two arms of the dipicolylaminomethyl groups, the effective ligands for Zn2+, was studied in the presence of Zn2+ and ATP. Upon complexation of the distyrylbenzene with zinc ions in acetonitrile, enhancement of the fluorescence intensity was observed due to inhibition of intramolecular PET (photo-induced electron transfer) quenching, but no effect was found in aqueous media because the equilibrium laid to the free form of the ligands. In contrast, the addition of ATP disodium salt was effective to enhance the fluorescence intensity of the combination of the distyrylbenzne and Zn2+ in aqueous media. This assembly was applied to the peroxyoxalate chemiluminescence system and a significant increase in the intensity was observed, which provides a potential detection for ATP by chemiluminescence.

  19. Projection model for flame chemiluminescence tomography based on lens imaging

    NASA Astrophysics Data System (ADS)

    Wan, Minggang; Zhuang, Jihui

    2018-04-01

    For flame chemiluminescence tomography (FCT) based on lens imaging, the projection model is essential because it formulates the mathematical relation between the flame projections captured by cameras and the chemiluminescence field, and, through this relation, the field is reconstructed. This work proposed the blurry-spot (BS) model, which takes more universal assumptions and has higher accuracy than the widely applied line-of-sight model. By combining the geometrical camera model and the thin-lens equation, the BS model takes into account perspective effect of the camera lens; by combining ray-tracing technique and Monte Carlo simulation, it also considers inhomogeneous distribution of captured radiance on the image plane. Performance of these two models in FCT was numerically compared, and results showed that using the BS model could lead to better reconstruction quality in wider application ranges.

  20. Measurement of salivary cortisol by a chemiluminescent organic-based immunosensor.

    PubMed

    Pires, N M M; Dong, T

    2014-01-01

    A highly sensitive chemiluminescent immunoassay (CLIA) using a sensitive organic photodetector was developed to detect human cortisol, an important biomarker for stress-related diseases. The developed CLIA was performed onto gold-coated glass chips, on which anti-cortisol antibodies were immobilised and chemiluminescent horseradish peroxidase-luminol-peroxide reactions were generated. Using cortisol-spiked artificial saliva samples, the CLIA biosensor showed a linear range of detection between 0.1 ng/mL and 175 ng/mL and a detection limit of 80 pg/mL. The sensor response was highly specific to cortisol and did not vary significantly between assays. The results indicate the potential clinical application of the CLIA sensor. Furthermore, the simple layered structure of the organic photodetector may encourage the realisation of integrated optical biosensors for point-of-use measurement of salivary cortisol levels.

  1. Chemiluminescent methods and instruments for monitoring of the atmosphere and satellite validation on board of research aircrafts and unmanned aerial vehicles

    NASA Astrophysics Data System (ADS)

    Sitnikov, Nikolay; Borisov, Yuriy; Akmulin, Dimitry; Chekulaev, Igor; Sitnikova, Vera; Ulanovsky, Alexey; Sokolov, Alexey

    The results of development of instruments based on heterophase chemiluminescence for measurements of space distribution of ozone and nitrogen oxides concentrations on board of research aircrafts and unmanned aerial vehicles carried out in Central Aerological Observatory are presented. Some results of atmospheric investigations on board of research aircrafts M55 “Geophysica” (Russia) and “Falcon” (Germany) carried out using developed instruments in frame of international projects are demonstrated. Small and low power instruments based on chemiluminescent principle for UAV are developed. The results of measurements on board of UAV are shown. The development can be used for satellite data validation, as well as operative environmental monitoring of contaminated areas in particular, chemical plants, natural and industrial disasters territories, areas and facilities for space purposes etc.

  2. Detecting free radicals in sunscreens exposed to UVA radiation using chemiluminescence.

    PubMed

    Millington, Keith R; Osmond, Megan J; McCall, Maxine J

    2014-04-05

    One of the current concerns with the application of nanoparticles in sunscreens, and in particular nano-TiO2 and ZnO, is their potential to photogenerate free radicals and reactive oxygen species (ROS) when they absorb ultraviolet wavelengths from sunlight. Free radicals and ROS are known to be associated with UV-induced skin damage and oxidative stress, from which sunscreens are expected to offer significant protection. Here we describe a simple method, based on chemiluminescence emission, for detecting free radicals generated in commercial sunscreens alone, and when applied to various substrates, following exposure to UVA (320-400nm) radiation. This photo-induced chemiluminescence (PICL) technique could be used to optimise sunscreen formulations so as to minimise free radical photogeneration during exposure to sunlight. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  3. Unprecedented chemiluminescence behaviour during peroxyoxalate chemiluminescence of oxalates with fluorescent or electron-donating aryloxy groups.

    PubMed

    Koike, Ryu; Kato, Yuji; Motoyoshiya, Jiro; Nishii, Yoshinori; Aoyama, Hiromu

    2006-01-01

    A series of diaryl and bis(4-styrylphenyl) oxalates with electron-donating substituents or fluorescent moieties were subjected to the peroxyoxalate chemiluminescence (PO-CL) reaction, some of which were found to behave in a unprecedented manner. The reaction of bis(p-methyoxyphenyl) oxalate, as a representative example, emits light due not only to the emission from the externally added excited fluorophore, but also from the presumable excimer of p-methoxyphenol. Also, during the reaction of the bis(4-styrylphenyl) oxalates, the emission based on the fluorescence as well as the excimer of the eliminating group were observed. These experimental results suggest that such emitting species would be formed by an intra- and intermolecular electronic interaction with a high-energy intermediate, such as a dioxetanone. Copyright (c) 2006 John Wiley & Sons, Ltd.

  4. Potassium permanganate-acridine yellow chemiluminescence system for the determination of fluvoxamine, isoniazid and ceftriaxone.

    PubMed

    Abolhasani, Jafar; Hassanzadeh, Javad

    2014-12-01

    Based on the oxidation of acridine yellow by permanganate in basic medium, a new chemiluminescence system was developed for the sensitive determination of some important drugs. The remarkable inhibiting effect of fluvoxamine, ceftriaxone and isoniazid on this reaction was applied to their detection. A possible mechanism was proposed for this system based on chemiluminescence emission wavelengths and experimental observations. Under optimum conditions, calibration graphs were obtained for 1 × 10(-9) to 1 × 10(-6) mol/L of fluvoxamine; 2 × 10(-8) to 8 × 10(-6) mol/L of ceftriaxone and 5 × 10(-8) to 4 × 10(-5) mol/L of isoniazid. This proposed method was satisfactorily used in the determination of these drugs in pharmaceutical samples and human urine and serum. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Comparative study of different fluorescent dyes for the detection of proteins on membranes using the peroxyoxalate chemiluminescent reaction.

    PubMed

    Salerno, Doris; Daban, Joan-Ramon

    2003-08-05

    We have previously shown that the bis(2,4,6-trichlorophenyl)oxalate (TCPO)-H(2)O(2) chemiluminescent reaction in acetone can be used for the detection of proteins labeled with the fluorescent reagent 2-methoxy-2,4-diphenyl-3(2H)-furanone (MDPF) on polyvinylidene difluoride (PVDF) membranes. To improve this method, in this work we have designed and constructed a cell that allows us to perform this chemiluminescent reaction on PVDF membranes with a homogeneous distribution of the reagents. Using this cell we have examined the analytical properties of several recently developed fluorescent protein dyes chemically different from MDPF. We have found that the metal chelate dye SYPRO Ruby can also be excited by the high-energy intermediate produced in the TCPO-H(2)O(2) reaction.

  6. Method for Predicting Hypergolic Mixture Flammability Limits

    DTIC Science & Technology

    2017-02-01

    liquid phase, in the gas phase, at the liquid / liquid interface and at the gas / liquid interface during hypergolic ignition and the interactions...of what happens in the liquid phase, in the gas phase, at the liquid / liquid interface and at the gas / liquid interface during hypergolic ignition...and the interactions of all these phases. The ignition happens in the gas -phase but products formed here and there (in the liquid phase or at

  7. CARBON DIOXIDE SEPARATION BY PHASE ENHANCED GAS-LIQUID ABSORPTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang Hu

    A new process called phase enhanced gas-liquid absorption has been developed in its early stage. It was found that adding another phase into the absorption system of gas/aqueous phase could enhance the absorption rate. A system with three phases was studied. In the system, gas phase was carbon dioxide. Two liquid phases were used. One was organic phase. Another was aqueous phase. By addition of organic phase into the absorption system of CO{sub 2}-aqueous phase, the absorption rate of CO{sub 2} was increased significantly. CO{sub 2} finally accumulated into aqueous phase. The experimental results proved that (1) Absorption rate ofmore » carbon dioxide was enhanced by adding organic phase into gas aqueous phase system; (2) Organic phase played the role of transportation of gas solute (CO{sub 2}). Carbon dioxide finally accumulated into aqueous phase.« less

  8. Optical-Fiber Fluorosensors With Polarized Light Sources

    NASA Technical Reports Server (NTRS)

    Egalon, Claudio O.; Rogowski, Robert S.

    1995-01-01

    Chemiluminescent and/or fluorescent molecules in optical-fiber fluorosensors oriented with light-emitting dipoles along transverse axis. Sensor of proposed type captures greater fraction of chemiluminescence or fluorescence and transmits it to photodetector. Transverse polarization increases sensitivity. Basic principles of optical-fiber fluorosensors described in "Making Optical-Fiber Chemical Sensors More Sensitive" (LAR-14525), "Improved Optical-Fiber Chemical Sensors" (LAR-14607), and "Improved Optical-Fiber Temperature Sensors" (LAR-14647).

  9. An Evaluation of the Eclox Chemiluminescence Test, Hach Pesticide/Nerve Agent Test Strips, and Agri-Screen Test Tickets

    DTIC Science & Technology

    2010-06-30

    Interference Testing Our testing shows that it is unlikely that the Eclox Chemiluminescence Test will respond to the common disinfectant chloramine ...common disinfectants (chlorine and chloramine ), cyanobacterial byproducts (geosmin and MIB) or water quality parameters (humic/fulvic acids or water...toxicity sensor testing Table 2-2: Interferences Test Chemicals Concentration (mg/L) Chlorine 10 Chloramines 10 Geosmin 0.0001 Methyl-isoborneol

  10. Schlieren and OH* chemiluminescence imaging of combustion in a turbulent boundary layer over a solid fuel

    NASA Astrophysics Data System (ADS)

    Jens, Elizabeth T.; Miller, Victor A.; Cantwell, Brian J.

    2016-03-01

    Combustion in a turbulent boundary layer over a solid fuel is studied using simultaneous schlieren and OH* chemiluminescence imaging. The flow configuration is representative of a hybrid rocket motor combustor. Six different hydrocarbon fuels, including both classical hybrid rocket fuels and a high regression rate fuel (paraffin wax), are burned in an undiluted oxygen free-stream at pressures ranging from atmospheric to 1524.2 kPa (221.1 psi). A detailed explanation of methods for registering the schlieren and OH* chemiluminescence images to one another is presented, and additionally, details of the routines used to extract flow features of interest (like the boundary layer height and flame location) are provided. At atmospheric pressure, the boundary layer location is consistent between all fuels; however, the flame location varies for each fuel. The flame zone appears to be smoothly distributed over the fuel surface at atmospheric pressure. At elevated pressures and correspondingly increased Dahmköhler number (but at constant Reynolds number), flame morphology is markedly different, exhibiting large rollers in a shear layer above the fuel grain and finer structures in the flame. The chemiluminescence intensity is found to be roughly proportional to the fuel burn rate at both atmospheric and elevated chamber pressures.

  11. Chemiluminescent imaging of transpired ethanol from the palm for evaluation of alcohol metabolism.

    PubMed

    Arakawa, Takahiro; Kita, Kazutaka; Wang, Xin; Miyajima, Kumiko; Toma, Koji; Mitsubayashi, Kohji

    2015-05-15

    A 2-dimensional imaging system was constructed and applied in measurements of gaseous ethanol emissions from the human palm. This imaging system measures gaseous ethanol concentrations as intensities of chemiluminescence by luminol reaction induced by alcohol oxidase and luminol-hydrogen peroxide-horseradish peroxidase system. Conversions of ethanol distributions and concentrations to 2-dimensional chemiluminescence were conducted on an enzyme-immobilized mesh substrate in a dark box, which contained a luminol solution. In order to visualize ethanol emissions from human palm skin, we developed highly sensitive and selective imaging system for transpired gaseous ethanol at sub ppm-levels. Thus, a mixture of a high-purity luminol solution of luminol sodium salt HG solution instead of standard luminol solution and an enhancer of eosin Y solution was adapted to refine the chemiluminescent intensity of the imaging system, and improved the detection limit to 3 ppm gaseous ethanol. The highly sensitive imaging allows us to successfully visualize the emissions dynamics of transdermal gaseous ethanol. The intensity of each site on the palm shows the reflection of ethanol concentrations distributions corresponding to the amount of alcohol metabolized upon consumption. This imaging system is significant and useful for the assessment of ethanol measurement of the palmar skin. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Introducing novel amorphous carbon nanoparticles as energy acceptors into a chemiluminescence resonance energy transfer immunoassay system.

    PubMed

    Wang, Zhenxing; Gao, Hongfei; Fu, Zhifeng

    2013-11-21

    A novel chemiluminescence resonance energy transfer (CRET) system for competitive immunoassay of biomolecules was developed by using novel amorphous carbon nanoparticles (CNPs) prepared from candle soot as energy acceptors. The CNPs were firstly prepared to bind with the antigen (Ag) for obtaining the nanocomposite CNP-Ag, and this obtained CNP-Ag was then reacted with the horseradish peroxidase-labeled antibody (HRP-Ab) to assemble the CRET system. The luminol catalyzed by HRP serving as the energy donor for CNPs triggered the CRET phenomenon between luminol and CNPs, which led to the chemiluminescence signal decrease. Due to the competitive immunoreaction of the target antigen and the CNP-Ag, a part of the CNP-Ag was replaced from the HRP-Ab, and then resulted in a weaker interaction between luminol and CNPs. Thus the competitive immunoreaction led to a higher chemiluminescence emission. This CNP-based CRET system was successfully applied to detect the human IgG as a model analyte, and a linear range of 10-200 ng mL(-1) and a detection limit of 1.9 ng mL(-1) (S/N = 3) were obtained. The results for real sample analysis demonstrated its application potential in some important areas such as clinical diagnosis.

  13. Chemiluminescent and chemiluminescence resonance energy transfer (CRET) detection of DNA, metal ions, and aptamer-substrate complexes using hemin/G-quadruplexes and CdSe/ZnS quantum dots.

    PubMed

    Freeman, Ronit; Liu, Xiaoqing; Willner, Itamar

    2011-08-03

    Nucleic acid subunits consisting of fragments of the horseradish peroxidase (HRP)-mimicking DNAzyme and aptamer domains against ATP or sequences recognizing Hg(2+) ions self-assemble, in the presence of ATP or Hg(2+), into the active hemin-G-quadruplex DNAzyme structure. The DNAzyme-generated chemiluminescence provides the optical readout for the sensing events. In addition, the DNAzyme-stimulated chemiluminescence resonance energy transfer (CRET) to CdSe/ZnS quantum dots (QDs) is implemented to develop aptamer or DNA sensing platforms. The self-assembly of the ATP-aptamer subunits/hemin-G-quadruplex DNAzyme, where one of the aptamer subunits is functionalized with CdSe/ZnS QDs, leads to the CRET signal. Also, the functionalization of QDs with a hairpin nucleic acid that includes the G-quadruplex sequence in a ''caged'' configuration is used to analyze DNA. The opening of the hairpin structure by the target DNA assembles the hemin-G-quadruplex DNAzyme that stimulates the CRET signal. By the application of three different sized QDs functionalized with different hairpins, the multiplexed analysis of three different DNA targets is demonstrated by the generation of three different CRET luminescence signals.

  14. Homogeneous assay of target molecules based on chemiluminescence resonance energy transfer (CRET) using DNAzyme-linked aptamers.

    PubMed

    Mun, Hyoyoung; Jo, Eun-Jung; Li, Taihua; Joung, Hyou-Arm; Hong, Dong-Gu; Shim, Won-Bo; Jung, Cheulhee; Kim, Min-Gon

    2014-08-15

    We have designed a single-stranded DNAzyme-aptamer sensor for homogeneous target molecular detection based on chemiluminescence resonance energy transfer (CRET). The structure of the engineered single-stranded DNA (ssDNA) includes the horseradish peroxidase (HRP)-like DNAzyme, optimum-length linker (10-mer-length DNA), and target-specific aptamer sequences. A quencher dye was modified at the 3' end of the aptamer sequence. The incorporation of hemin into the G-quadruplex structure of DNAzyme yields an active HRP-like activity that catalyzes luminol to generate a chemiluminescence (CL) signal. In the presence of target molecules, such as ochratoxin A (OTA), adenosine triphosphate (ATP), or thrombin, the aptamer sequence was folded due to the formation of the aptamer/analyte complex, which induced the quencher dye close to the DNAzyme structure. Consequently, the CRET occurred between a DNAzyme-catalyzed chemiluminescence reaction and the quencher dye. Our results showed that CRET-based DNAzyme-aptamer biosensing enabled specific OTA analysis with a limit of detection of 0.27ng/mL. The CRET platform needs no external light source and avoids autofluorescence and photobleaching, and target molecules can be detected specifically and sensitively in a homogeneous manner. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Determination of the pseudoephedrine content in pharmaceutical formulations and in biological fluids using a microbore HPLC system interfaced to a microfluidic chemiluminescence detector.

    PubMed

    Kadavilpparampu, Afsal Mohammed; Al-Lawati, Haider A J; Suliman, FakhrEldin O; Al Kindy, Salma M Z

    2015-12-01

    A novel automated precolumn derivatization followed by separation using liquid chromatography for the determination of pseudoephedrine (PSE) by a microfluidic chemiluminescence detector has been developed. An on-line derivatization procedure was utilized by converting PSE into a highly light emitting species in a Ru(bipy)3(2+)-peroxydisulphate chemiluminescence (CL) system by derivatizing it with a 1.0 M formaldehyde solution. The derivatized analyte was directly injected into a microbore high-performance liquid chromatography (HPLC) system coupled to an on-chip chemiluminescence detector. The newly developed highly selective, sensitive and fast HPLC-CL method was validated and successfully applied for the analysis of PSE in pharmaceutical formulations and a human urine sample. The selectivity of the method is not only due to the HPLC separation but is also due to the highly selective detection principle of the Ru(bipy)3(2+)-peroxydisulphate CL system used. There was no interference observed from the common preservatives and excipients used in pharmaceutical preparations, which did not show any significant CL signal. The retention time of PSE was less than 3 min, and the detection limits and quantification limits were found to be 5.7 and 26.0 µg L(-1), respectively. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Simultaneous determination of isoniazid and p-aminosalicylic acid by capillary electrophoresis using chemiluminescence detection.

    PubMed

    Zhang, Xinfeng; Xuan, Yuelan; Sun, Aimin; Lv, Yi; Hou, Xiandeng

    2009-01-01

    It was found that isoniazid (ISO) or p-aminosalicylic acid (PAS) could enhance the chemiluminescence (CL) emission from Cu (II)-luminol-hydrogen peroxide system, and the increased chemiluminescence signals were proportional to their concentrations, respectively. Based on this phenomenon, a chemiluminescence method coupled to capillary electrophoresis (CE) was established for simultaneous determination of ISO and PAS. The CE conditions including running buffer and running voltage were investigated in detail. The effects of the pH of H(2)O(2) solution and the concentrations of luminol, H(2)O(2) and Cu (II) on the CL signal were also investigated carefully. Under the optimized conditions, the analysis could be accomplished within 10 min, with the limits of detection of 0.3 microg mL(-1) for ISO and 1.1 microg mL(-1) for PAS, corresponding to 7.2 and 26.4 pg per injection (24 nL), respectively. Finally, the method was validated by determining the two analytes in pharmaceutical preparation and spiked human serum samples. The results of pharmaceutical tablet analysis were in good agreement with the labeled amounts. The recoveries for ISO and PAS in human serum were in the range of 92-104% and 90-113%, respectively. Copyright 2008 John Wiley & Sons, Ltd.

  17. The effect of storage on whole blood chemiluminescence measurement of equine neutrophils.

    PubMed

    Krumrych, Wiesław; Skórzewski, Radosław; Malinowski, Edward

    2013-01-01

    The aim of this study was to determine the effect of duration and temperature of sample storage on whole blood chemiluminescence measurement results. Venous blood from 18 clinically healthy Polish half-bred horses aged 4 to 11 years were used in the study. Luminol dependent chemiluminescence (CL) was used to measure neutrophil oxygen metabolism in whole blood. Blood samples were examined for spontaneous CL and stimulated by a surface receptor stimulus as well as extra-receptor stimulus. The assay was performed in two parallel experimental sets with samples stored at 4 and 22 °C, respectively. Whole blood CL was estimated at 2, 6, 24, 48, 72, 96 and 120 h after collection. The study demonstrated that temperature and duration of sample storage are factors that determine the quality of CL measurements of whole blood in horses. The study concluded that samples should be stored at 4 °C and the assay should be performed as early as possible. It was also shown that the viability period of horse blood for CL assays is relatively long. Material stored at room temperature for 24 h and even up to 48 h at 4 °C did not show any significant decrease in spontaneous or stimulated chemiluminescence. Copyright © 2012 John Wiley & Sons, Ltd.

  18. Chemiluminescent optical fiber immunosensor for detection of autoantibodies to ovarian and breast cancer-associated antigens.

    PubMed

    Salama, Orly; Herrmann, Sebastien; Tziknovsky, Alina; Piura, Benjamin; Meirovich, Michael; Trakht, Ilya; Reed, Brent; Lobel, Leslie I; Marks, Robert S

    2007-02-15

    We report herein the development of an optical fiber based chemiluminescent immunosensor for detection of the native autoimmune response to GIPC-1, a PDZ containing protein involved in regulation of G-protein signaling. The recombinant protein GIPC-1 was expressed in bacteria, purified, refolded and conjugated to the tip of an optical fiber. A human monoclonal 27.B1 IgM isolated from a breast cancer patient, which targets the GIPC-1 protein, was used for calibration of the immunosensor and was detected down to a concentration of 30 pg/ml. We determined that the fiber-optic immunosensor had a detection limit 50 times lower than chemiluminescent ELISA, and approximately 500 times lower than colorimetric ELISA. In addition, sera from 11 ovarian cancer patients, 22 breast cancer patients and asymptomatic controls were tested for the presence of IgM anti-GIPC-1 autoantibodies in their serum using the two methods. The immunosensor assay detected 54% and 77% GIPC-1 positive sera within ovarian and breast cancer patients, respectively, as compared to chemiluminescent ELISA, which only detected 18% and 27%, respectively. We envision that this immunosensor may serve as a diagnostic tool for screening women for ovarian and breast cancer at an early stage, thus increasing their chance of survival.

  19. Investigation of methyl decanoate combustion in an optical direct-injection diesel engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, A. S.; Dumitrescu, Cosmin E.; Mueller, Charles J.

    In this study, an optically accessible heavy-duty diesel engine was used to investigate the impact of methyl decanoate (MD) on combustion and emissions. A specific goal of the study was to determine if MD could enable soot-free leaner-lifted flame combustion (LLFC) – a mode of mixing-controlled combustion associated with fuel-air equivalence ratios below approximately two. An ultra-low sulfur diesel certification fuel (CF) was used as the baseline fuel, and experiments were conducted at two fuel-injection pressures with three levels of charge-gas dilution. In addition to conventional pressure-based and engine-out emissions measurements, exhaust laser-induced incandescence, in-cylinder natural luminosity (NL), and in-cylindermore » chemiluminescence (CL) diagnostics were used to provide detailed insight into combustion processes.« less

  20. Investigation of methyl decanoate combustion in an optical direct-injection diesel engine

    DOE PAGES

    Cheng, A. S.; Dumitrescu, Cosmin E.; Mueller, Charles J.

    2014-11-24

    In this study, an optically accessible heavy-duty diesel engine was used to investigate the impact of methyl decanoate (MD) on combustion and emissions. A specific goal of the study was to determine if MD could enable soot-free leaner-lifted flame combustion (LLFC) – a mode of mixing-controlled combustion associated with fuel-air equivalence ratios below approximately two. An ultra-low sulfur diesel certification fuel (CF) was used as the baseline fuel, and experiments were conducted at two fuel-injection pressures with three levels of charge-gas dilution. In addition to conventional pressure-based and engine-out emissions measurements, exhaust laser-induced incandescence, in-cylinder natural luminosity (NL), and in-cylindermore » chemiluminescence (CL) diagnostics were used to provide detailed insight into combustion processes.« less

  1. Recent developments in cyanide detection: A review

    PubMed Central

    Ma, Jian; Dasgupta, Purnendu K.

    2010-01-01

    The extreme toxicity of cyanide and environmental concerns from its continued industrial use continue to generate interest in facile and sensitive methods for cyanide detection. In recent years there is also additional recognition of HCN toxicity from smoke inhalation and potential use of cyanide as a weapon of terrorism. This review summarizes the literature since 2005 on cyanide measurement in different matrices ranging from drinking water and wastewater, to cigarette smoke and exhaled breath to biological fluids like blood, urine and saliva. The dramatic increase in the number of publications on cyanide measurement is indicative of the great interest in this field not only from analytical chemists, but also researchers from diverse environmental, medical, forensic and clinical arena. The recent methods cover both established and emerging analytical disciplines and include naked eye visual detection, spectrophotometry/colorimetry, capillary electrophoresis with optical absorbance detection, fluorometry, chemiluminescence, near-infrared cavity ring down spectroscopy, atomic absorption spectrometry, electrochemical methods (potentiometry/amperometry/ion chromatography-pulsed amperometry), mass spectrometry (selected ion flow tube mass spectrometry, electrospray ionization mass spectrometry, gas chromatography-mass spectrometry), gas chromatography (nitrogen phosphorus detector, electron capture detector) and quartz crystal mass monitors. PMID:20599024

  2. Detection of indomethacin by high-performance liquid chromatography with in situ electrogenerated Mn(III) chemiluminescence detection.

    PubMed

    Zhang, Yantu; Zhang, Zhujun; Qi, Guangcai; Sun, Yonghua; Wei, Yue; Ma, Hongyan

    2007-01-23

    The determination of indomethacin (INM) in pharmaceutical and biological samples by means of high-performance liquid chromatography (HPLC) with in situ electrogenerated Mn(III) chemiluminescence (CL) detection was proposed. The method was based on the direct CL reaction of INM and Mn(III), which was in situ electrogenerated by constant current electrolysis. The chromatographic separation was carried out on Nucleosil RP-C(18) column (250 mm x 4.6 mm; i.d., 5 microm; pore size, 100 A) at 20 degrees C. The mobile phase consisted of methanol:water:acetic acid=67:33:0.1 solution. At a flow rate of 1.0 mL min(-1), the total run time was 10 min. The effects of several parameters on the HPLC resolution and CL emission were studied systematically. Under the optimal conditions, a linear range from 0.01 to 10 microg mL(-1)(R(2)=0.9991), and a detection limit of 8 ng mL(-1) (signal-to-noise ratio=3) for INM were achieved. The relative standard deviations (R.S.D.) for 0.1 microg mL(-1) INM were 2.2% within a day (n=11) and 3.0% on 5 consecutive days (n=6), respectively. The recovery of INM from urine samples was more than 92%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.

  3. Effects of Non-Equilibrium Plasmas on Low-Pressure, Premixed Flames. Part 1: CH* Chemiluminescence, Temperature, and OH

    DTIC Science & Technology

    2018-01-16

    1    Effects of Non -Equilibrium Plasmas on Low-Pressure, Premixed Flames. Part 1: CH* Chemiluminescence, Temperature, and OH Ting Li, Igor V...investigate the effects of nanosecond, repetitively-pulsed, non -equilibrium plasma discharges on laminar, low-pressure, premixed burner-stabilized hydrogen/O2...sources, both of which generate uniform, low-temperature, volumetric, non -equilibrium plasma discharges, are used to study changes in

  4. Proceedings of the First International Symposium on Explosive Detection Technology

    DTIC Science & Technology

    1992-05-01

    of these per unit volume is C, = 2.0 ct /cm 3/sec. For the 10 metals make the activity concentration significantly seconds that the bag is in the...Hopfield Network CI Chemical Ionization CL Chemiluminescence CLD Chemiluminescence Detector CPU Central Processing Unit CT Computed Tomography CW...NOTICE This document is disseminated under the sponsorship of the U.S. Department of Transportation in the Interest of Information exchange. The United

  5. NO sub X destruction by CO in NO sub X to NO converters of chemiluminescent NO analyzers

    NASA Technical Reports Server (NTRS)

    Summers, R. L.

    1976-01-01

    An instrument modification for chemiluminescent NO - NOx analyzers was developed which minimizes the NOx destruction in the NOx to NO converters of NO analyzers due to high concentrations of CO. This mechanism causes the NO analyzers to indicate incorrect NOx concentrations when the analyzers are operated in the NOx analysis mode. The modification is applicable to analyzers in which the detection chamber is evacuated.

  6. Auroral nitric oxide concentration and infrared emission

    NASA Astrophysics Data System (ADS)

    Reidy, W. P.; Degges, T. C.; Hurd, A. G.; Stair, A. T., Jr.; Ulwick, J. C.

    1982-05-01

    Rocket-borne measurements of infrared auroral emission by nitric oxide are analyzed. Four rocket flights provided opportunities to measure 5.3- and 2.7-micron NO emission by means of infrared fixed band radiometers and CVF spectrometers, narrow band photometers, and incident energy spectra on various occasions. Analysis of infrared emission profiles and electron flux data indicates the NO density to be significantly enhanced with respect to midlatitude values. NO emission in the fundamental 5.3-micron band is attributed to resonance excitation by warm earth radiation, collisional excitation primarily by O atoms and chemiluminescence from the reaction of N with O2; with an energy efficiency of 0.015. The overtone band emission at 2.7 microns is accounted for by chemiluminescence produced with an energy efficiency of 0.0054. Total photon yield for the chemiluminescence reaction is estimated to range from 1.2 to 2.4 vibrational quanta per NO molecule.

  7. Facile chemiluminescence assay for antioxidative properties of vegetable lipids: fundamentals and illustrative examples.

    PubMed

    Fedorova, Galina F; Menshov, Valery A; Trofimov, Alexey V; Vasil'ev, Rostislav F

    2009-10-01

    The general approach disclosed herein opens the new possibilities of exploiting the oxidation processes followed by chemiluminescence (CL) emission for the assessment of an antioxidant potential of natural lipid materials and enables determination of the amount and strength of lipid-borne antioxidants in one experiment. The reliability of the analytical procedure is completely unaffected by an inevitable entering of oxidizable lipid portions into the probe chemiluminescent mixture, which is exemplarily illustrated for the case of vegetable oils which served as sources of antioxidant-containing lipids. As a matter of fact, the difference in the effective radical-scavenging rate constants, determined for the antioxidative constituents of the sunflower and corn oils, perfectly matches the distinction of their qualitative tocopherol contents. In addition to the antiradical activity of lipid samples, the antioxidant potential of the latter may be modified by their influence on hydroperoxide stability, as it has been also demonstrated in the present work.

  8. Bioinspired photonic structures by the reflector layer of firefly lantern for highly efficient chemiluminescence

    PubMed Central

    Chen, Linfeng; Shi, Xiaodi; Li, Mingzhu; Hu, Junping; Sun, Shufeng; Su, Bin; Wen, Yongqiang; Han, Dong; Jiang, Lei; Song, Yanlin

    2015-01-01

    Fireflies have drawn considerable attention for thousands of years due to their highly efficient bioluminescence, which is important for fundamental research and photonic applications. However, there are few reports on the reflector layer (RL) of firefly lantern, which contributes to the bright luminescence. Here we presented the detailed microstructure of the RL consisting of random hollow granules, which had high reflectance in the range from 450 nm to 800 nm. Inspired by the firefly lantern, artificial films with high reflectance in the visible region were fabricated using hollow silica microparticles mimicking the structure of the RL. Additionally, the bioinspired structures provided an efficient RL for the chemiluminescence system and could substantially enhance the initial chemiluminescence intensity. The work not only provides new insight into the bright bioluminescence of fireflies, but also is importance for the design of photonic materials for theranostics, detection, and imaging. PMID:26264643

  9. Post-chemiluminescence determination of chloramphenicol based on luminol-potassium periodate system.

    PubMed

    Yang, Xiao Feng; Li, Nian Bing; Luo, Hong Qun

    2012-01-01

    A post-chemiluminescence (PCL) phenomenon was observed when chloramphenicol was injected into a mixture of luminol and potassium periodate after the chemiluminescence (CL) reaction of luminol-potassium periodate had finished. The possible reaction mechanism was proposed based on studies of the CL kinetic characteristics, the CL spectra, the fluorescence spectra and the UV-vis absorption spectra of the related substances. Based on the PCL reaction, a rapid and sensitive method for the determination of chloramphenicol was established. The linear response range was 6.0 × 10(-7) -1.0 × 10(-5) mol/L, with a correlation coefficient of 0.9986. The relative standard deviation (RSD) for 5.0 × 10(-6) mol/L chloramphenicol was 2.3% (n = 11). The detection limit was 1.6 × 10(-7) mol/L. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.

  10. Determination of estradiol valerate in pharmaceutical preparations and human serum by flow injection chemiluminescence.

    PubMed

    Liu, Wenwen; Xie, Liangxiao; Liu, Hongshuang; Xu, Shichao; Hu, Bingcheng; Cao, Wei

    2013-01-01

    A novel method for the detection of trace estradiol valerate (EV) in pharmaceutical preparations and human serum was developed by inhibition of luminol chemiluminescence (CL) by estradiol valerate on the zinc deuteroporphyrin (ZnDP)-enhanced luminol-K3 Fe(CN)6 chemiluminescence system. Under optimized experimental conditions, CL intensity and concentration of estradiol valerate had a good linear relationship in the ranges of 8.0 × 10(-8) to 1.0 × 10(-5) g/mL. Detection limit (3σ) was estimated to be 3.5 × 10(-8) g/mL. The proposed method was applied successfully for the determination of estradiol valerate in pharmaceutical preparations and human serum and recoveries were 97.0-105.0% and 95.5-106.0%, respectively. The possible mechanism of the CL system is discussed. Copyright © 2012 John Wiley & Sons, Ltd.

  11. Chemiluminescence of the reaction system Ce(IV)-non-steroidal anti-inflammatory drugs containing europium(III) ions and its application to the determination of naproxen in pharmaceutical preparations and urine.

    PubMed

    Kaczmarek, Małgorzata

    2011-11-01

    The chemiluminescence (CL) of oxidation of non-steroidal anti-inflammatory drugs (NSAIDs) by Ce(IV) ions, was recorded in the presence and absence europium(III) ions, in solution of pH ~ 4 of solution. Kinetic curves and CL emission spectra of the all studied systems were discussed. CL of measurable intensity was observed in the Ce(IV)-NP-Eu(III) reaction system only in acidic solutions. The CL spectrum rcegistered for this system shows emission bands, typical of Eu(III) ions, with maximum at λ ~ 600 nm. The chemiluminescent method, based on Eu(III) emission in reaction system of NP-Ce(IV)-Eu(III) in acid solution was therefore used for the determination of naproxen in mixture of non-steroidal anti-inflammatory drugs.

  12. Rapid determination of isoamyl nitrite in pharmaceutical preparations by flow injection analysis with on-line UV irradiation and luminol chemiluminescence detection.

    PubMed

    Kishikawa, Naoya; Kondo, Naoko; Amponsaa-Karikari, Abena; Kodamatani, Hitoshi; Ohyama, Kaname; Nakashima, Kenichiro; Yamazaki, Shigeo; Kuroda, Naotaka

    2014-02-01

    Isoamyl nitrite is used as a therapeutic reagent for cardiac angina and as an antidote for cyanide poisoning, but it is abused because of its euphoric properties. Therefore, a method to determine isoamyl nitrite is required in many fields, including pharmaceutical and forensic studies. In this study, a simple, rapid and sensitive method for the determination of isoamyl nitrite was developed using a flow injection analysis system equipped with a chemiluminescence detector and on-line photoreactor. This method is based on on-line ultraviolet irradiation of isoamyl nitrite and subsequent luminol chemiluminescence detection without the addition of an oxidant. A linear standard curve was obtained up to 1.0 μM of isoamyl nitrite with a detection limit (blank + 3SD) of 0.03 μM. The method was successfully applied to determine isoamyl nitrite content in pharmaceutical preparations. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Determination of dipyrone in pharmaceutical preparations based on the chemiluminescent reaction of the quinolinic hydrazide-H2O2-vanadium(IV) system and flow-injection analysis.

    PubMed

    Pradana Pérez, Juan A; Durand Alegría, Jesús S; Hernando, Pilar Fernández; Sierra, Adolfo Narros

    2012-01-01

    A rapid, economic and sensitive chemiluminescent method involving flow-injection analysis was developed for the determination of dipyrone in pharmaceutical preparations. The method is based on the chemiluminescent reaction between quinolinic hydrazide and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. Principal chemical and physical variables involved in the flow-injection system were optimized using a modified simplex method. The variations in the quantum yield observed when dipyrone was present in the reaction medium were used to determine the concentration of this compound. The proposed method requires no preconcentration steps and reliably quantifies dipyrone over the linear range 1-50 µg/mL. In addition, a sample throughput of 85 samples/h is possible. Copyright © 2011 John Wiley & Sons, Ltd.

  14. Chimeric green fluorescent protein-aequorin as bioluminescent Ca2+ reporters at the single-cell level

    PubMed Central

    Baubet, Valérie; Le Mouellic, Hervé; Campbell, Anthony K.; Lucas-Meunier, Estelle; Fossier, Philippe; Brûlet, Philippe

    2000-01-01

    Monitoring calcium fluxes in real time could help to understand the development, the plasticity, and the functioning of the central nervous system. In jellyfish, the chemiluminescent calcium binding aequorin protein is associated with the green fluorescent protein and a green bioluminescent signal is emitted upon Ca2+ stimulation. We decided to use this chemiluminescence resonance energy transfer between the two molecules. Calcium-sensitive bioluminescent reporter genes have been constructed by fusing green fluorescent protein and aequorin, resulting in much more light being emitted. Chemiluminescent and fluorescent activities of these fusion proteins have been assessed in mammalian cells. Cytosolic Ca2+ increases were imaged at the single-cell level with a cooled intensified charge-coupled device camera. This bifunctional reporter gene should allow the investigation of calcium activities in neuronal networks and in specific subcellular compartments in transgenic animals. PMID:10860991

  15. Analysis of the chemiluminescence from electronically excited lead oxide generated in a flow tube reactor

    NASA Astrophysics Data System (ADS)

    Dorko, E. A.; Glessner, J. W.; Ritchey, C. M.; Rutger, L. L.; Pow, J. J.; Brasure, L. D.; Duray, J. P.; Snyder, S. R.

    1986-03-01

    The chemiluminescence from electronically excited lead oxide formed during the reaction between lead vapor and either 3Σ O 2 or 1Δ O 2 has been studied. The reactions were accomplished in a flow tube reactor. A microwave discharge was used to generate 1Δ O 2. The vibronic spectrum was analyzed and the band head assignments were used in a linear least-squares calculation to obtain the vibronic molecular constants for the X, a, b, A, B, C, C', D, and E electronic states of lead oxide. Based on these and other molecular constants, Franck-Condon factors were calculated for the transitions to the ground state and also for the A-a and D-a transitions. Evidence was presented to support a kinetic analysis of the mechanism leading to chemiluminescence under the experimental conditions encountered in the flow tube reactor. Mechanisms presented earlier were verified by the present data.

  16. Artemisinin-Luminol Chemiluminescence for Forensic Bloodstain Detection Using a Smart Phone as a Detector.

    PubMed

    Gao, Wenyue; Wang, Chao; Muzyka, Kateryna; Kitte, Shimeles Addisu; Li, Jianping; Zhang, Wei; Xu, Guobao

    2017-06-06

    Forensic luminol chemiluminescence test is one of the most sensitive and popular methods for the determination of latent bloodstains. It mainly uses hydrogen peroxide or sodium perborate as coreactants. The easy decomposition of hydrogen peroxide and sodium perborate in the presence of many ions significantly affects the selectivity. Artemisinin is a natural peroxide that is quite stable in the presence of common ions. In the present study, artemisinin has been exploited for the forensic bloodstain chemiluminescence detection for the first time. Using smart phone as cost-effective portable detector, the visual detection of bloodstains has been achieved with a dilution factor of blood up to 100 000. Moreover, this system shows excellent selectivity against many common species. It can well differentiate bloodstains from other stains, such as coffee, brown sugar, and black tea. Both favorable sensitivity and selectivity makes the present method promising in forensic detection.

  17. Phagocytic and chemiluminescent responses of mouse peritoneal macrophages to living and killed Salmonella typhimurium and other bacteria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tomita, T.; Blumenstock, E.; Kanegasaki, S.

    1981-06-01

    In the presence of luminol, resident as well as thioglycolate-induced and immunized macrophages emitted chemiluminescence more efficiently when the cells were exposed to living Salmonella typhimurium than when they were exposed to the same bacterium killed by ultraviolet light or heat. This phenomenon was observed whether or not the bacterium was opsonized. The different response to living and killed bacteria was also found with Escherichia coli, Pseudomonas aeruginosa, Proteus morganii, and Enterobacter aerogenes, but not with Shigella sonnei, Klebsiella pneumoniae, and Propionibacterium acnes. The results suggest that macrophages respond better to living, motile bacteria than to nonmotile or killed bacteria.more » The experimental results obtained with motility mutants of S. typhimurium, E. coli, and P. aeruginosa confirm that macrophages exposed to the motile bacteria emit chemiluminescence more efficiently and ingest the motile bacteria at a much faster rate than the nonmotile bacteria.« less

  18. Sulfur-containing compounds quench 3,7-dihydro-2-methyl-6-(4-methoxyphenyl)imidazol[1,2-a]pyrazine-3-one chemiluminescence: Discrimination between true antioxidants and quenchers using xanthine oxidase.

    PubMed

    Kruglov, Alexey G; Nikiforova, Anna B; Shatalin, Yuri V; Shubina, Viktoria V; Fisyuk, Alexander S; Akatov, Vladimir S

    2010-11-15

    The probe 3,7-dihydro-2-methyl-6-(4-methoxyphenyl)imidazol[1,2-a]pyrazine-3-one (MCLA) is widely used for studying the superoxide anion production and the efficiency of antioxidants in biological systems. Here we report that a number of sulfur-containing compounds applied in biochemical and cytological studies are able to suppress MCLA-derived chemiluminescence (MDCL) independent of their capability to scavenge superoxide anion. The most effective MDCL quenchers appeared to be the substances with thiocarbamoyl and thiocarbonyl groups coupled to cyclic molecules and several thiol- and disulfide-containing compounds. The analysis of MDCL kinetics in a xanthine oxidase system allows one to rapidly discriminate between true antioxidants and the quenchers of chemiluminescence. Copyright 2010 Elsevier Inc. All rights reserved.

  19. Development of a chemiluminescent and bioluminescent system for the detection of bacteria in wastewater effluent

    NASA Technical Reports Server (NTRS)

    Thomas, R. R.

    1975-01-01

    Automated chemiluminescent and bioluminescent sensors were developed for continuous monitoring of microbial levels in wastewater effluent. Development of the chemiluminescent system included optimization of reagent concentrations as well as two new techniques which will allow for increased sensitivity and specificity. The optimal reagent concentrations are 0.0025 M luminol and 0.0125 M sodium perborate in 0.75N sodium hydroxide before addition of sample. The methods developed to increase specificity include (1) extraction of porphyrins from bacteria collected in a filter using 0.1N NaOH - 50 percent Ethanol, and (2) use of the specific reaction rate characteristics for the different luminol catalysts. Since reaction times are different for each catalyst, the reaction can be made specific for bacteria by measuring only the light emission from the particular reaction time zone specific for bacteria. Developments of the bioluminescent firefly luciferase system were in the area of flow system design.

  20. Chemiluminescence imaging ELISA using an imprinted polymer as the recognition element instead of an antibody.

    PubMed

    Surugiu, I; Danielsson, B; Ye, L; Mosbach, K; Haupt, K

    2001-02-01

    An imaging assay analogous to competitive enzyme immunoassays has been developed using a molecularly imprinted polymer instead of an antibody. The antigen 2,4-dichlorophenoxyacetic acid (2,4-D) was labeled with tobacco peroxidase, and the chemiluminescence reaction of luminol was used for detection. Microtiter plates (96 or 384 wells) were coated with polymer microspheres imprinted with 2,4-D, which were fixed in place by using poly(vinyl alcohol) as glue. In a competitive mode, the analyte-peroxidase conjugate was incubated with the free analyte in the microtiter plate, after which the bound fraction of the conjugate was quantified. After addition of the chemiluminescent substrates, light emission was measured in a high-throughput imaging format with a CCD camera. Calibration curves corresponding to analyte concentrations ranging from 0.01 to 100 microg/mL were obtained.

  1. Some Fundamental Experiments on Apparent Dissolution Rate of Gas Phase in the Groundwater Recovery Processes of the Geological Disposal System - 12146

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshii, Taiki; Niibori, Yuichi; Mimura, Hitoshi

    The apparent dissolution rates of gas phase in the co-presence of solid phase were examined by in-room experiments in this study. The apparent dissolution rate of gas phase q (mol/m{sup 3}.s) was generally defined by q=aK{sub L}(γP{sub g}-c), where a (1/m) is specific surface area of the interface between gas and liquid phases, K{sub L} (m/s) is overall mass transfer coefficient, γ (mol/(Pa.m{sup 3})) is reciprocal number of Henry constant, P{sub g} (Pa) is partial pressure of gas phase, and c (mol/m{sup 3}) is the concentration of gas component in liquid phase. As a model gas, CO{sub 2} gas wasmore » used. For evaluating the values of K{sub L}, this study monitored pH or the migration rate of the interface between water/gas phases, using some experiments such as the packed beds and the micro channel consisting of granite chip and rubber sheet including a slit. In the results, the values of K{sub L} were distributed in the range from 5.0x10{sup -6} m/s to 5.0x10{sup -7} m/s. These values were small, in comparison with that (7.8x10{sup -4} m/s) obtained from the bubbling test where gas phase was continually injected into deionized water without solid phase. This means that the solid phase limits the local mixing of water phase near gas-liquid interfaces. (authors)« less

  2. Design and Application of Multi-functional Electrogenerated Chemiluminescence Imaging Analyzer.

    PubMed

    Jiang, Guangfu; Liu, Xia; Wang, Yaqin; Ruan, Sanpeng; Qi, Honglan; Yang, Yong; Zhou, Qishe; Zhang, Chengxiao

    2016-01-01

    A multi-functional eletrogenerated chemiluminescence (ECL) imaging analyzer including both a photomultiplier tube and charged coupled device as detectors has been developed. The ECL imaging analyzer can effectively work for electrochemical study, ECL intensity detection at electrode array, and ECL imaging at bipolar electrodes or electrode array. As an ECL imaging example, an ECL biosensor for visual detection of matrix metalloproteinase 7 in the range from 0.05 to 1 ng/mL is demonstrated.

  3. Chemiluminescence enzyme immunoassay using ProteinA-bacterial magnetite complex

    NASA Astrophysics Data System (ADS)

    Matsunaga, Tadashi; Sato, Rika; Kamiya, Shinji; Tanaka, Tsuyosi; Takeyama, Haruko

    1999-04-01

    Bacterial magnetic particles (BMPs) which have ProteinA expressed on their surface were constructed using magA which is a key gene in BMP biosynthesis in the magnetic bacterium Magnetospirillum sp. AMB-1. Homogenous chemiluminescence enzyme immunoassay using antibody bound ProteinA-BMP complexes was developed for detection of human IgG. A good correlation between the luminescence yield and the concentration of human IgG was obtained in the range of 1-10 3 ng/ml.

  4. A BODIPY-luminol chemiluminescent resonance energy-transfer (CRET) cassette for imaging of cellular superoxide.

    PubMed

    Bag, S; Tseng, J-C; Rochford, J

    2015-02-14

    Spectroscopic and in cellulo studies are here reported on the very first BODIPY-luminol chemiluminescent resonance energy-transfer (CRET) cassette where the luminol CL agent is covalently linked to the BODIPY energy-transfer acceptor in a molecular dyad. The efficiency of intramolecular CRET investigated for the BODIPY-luminol dyad was found to be 64% resulting in a dual emissive response. Successful in cellulo biochemiluminescence via CRET was achieved in PMA activated splenocytes.

  5. CdTe quantum dots@luminol as signal amplification system for chrysoidine with chemiluminescence-chitosan/graphene oxide-magnetite-molecularly imprinting sensor

    NASA Astrophysics Data System (ADS)

    Duan, Huimin; Li, Leilei; Wang, Xiaojiao; Wang, Yanhui; Li, Jianbo; Luo, Chuannan

    2016-01-01

    A sensitive chemiluminescence (CL) sensor based on chemiluminescence resonance energy transfer (CRET) in CdTe quantum dots@luminol (CdTe QDs@luminol) nanomaterials combined with chitosan/graphene oxide-magnetite-molecularly imprinted polymer (Cs/GM-MIP) for sensing chrysoidine was developed. CdTe QDs@luminol was designed to not only amplify the signal of CL but also reduce luminol consumption in the detection of chrysoidine. On the basis of the abundant hydroxy and amino, Cs and graphene oxide were introduced into the GM-MIP to improve the adsorption ability. The adsorption capacities of chrysoidine by both Cs/GM-MIP and non-imprinted polymer (Cs/GM-NIP) were investigated, and the CdTe QDs@luminol and Cs/GM-MIP were characterized by UV-vis, FTIR, SEM and TEM. The proposed sensor can detect chrysoidine within a linear range of 1.0 × 10- 7 - 1.0 × 10- 5 mol/L with a detection limit of 3.2 × 10- 8 mol/L (3δ) due to considerable chemiluminescence signal enhancement of the CdTe quantum dots@luminol detector and the high selectivity of the Cs/GM-MIP system. Under the optimal conditions of CL, the CdTe QDs@luminol-Cs/GM-MIP-CL sensor was used for chrysoidine determination in samples with satisfactory recoveries in the range of 90-107%.

  6. Microspot-based ELISA in microfluidics: chemiluminescence and colorimetry detection using integrated thin-film hydrogenated amorphous silicon photodiodes.

    PubMed

    Novo, Pedro; Prazeres, Duarte Miguel França; Chu, Virginia; Conde, João Pedro

    2011-12-07

    Microfluidic technology has the potential to decrease the time of analysis and the quantity of sample and reactants required in immunoassays, together with the potential of achieving high sensitivity, multiplexing, and portability. A lab-on-a-chip system was developed and optimized using optical and fluorescence microscopy. Primary antibodies are adsorbed onto the walls of a PDMS-based microchannel via microspotting. This probe antibody is then recognised using secondary FITC or HRP labelled antibodies responsible for providing fluorescence or chemiluminescent and colorimetric signals, respectively. The system incorporated a micron-sized thin-film hydrogenated amorphous silicon photodiode microfabricated on a glass substrate. The primary antibody spots in the PDMS-based microfluidic were precisely aligned with the photodiodes for the direct detection of the antibody-antigen molecular recognition reactions using chemiluminescence and colorimetry. The immunoassay takes ~30 min from assay to the integrated detection. The conditions for probe antibody microspotting and for the flow-through ELISA analysis in the microfluidic format with integrated detection were defined using antibody solutions with concentrations in the nM-μM range. Sequential colorimetric or chemiluminescence detection of specific antibody-antigen molecular recognition was quantitatively detected using the photodiode. Primary antibody surface densities down to 0.182 pmol cm(-2) were detected. Multiplex detection using different microspotted primary antibodies was demonstrated.

  7. Inhibition of chemiluminescence and chemotactic activity of phagocytes in vitro by the extracts of selected medicinal plants.

    PubMed

    Jantan, Ibrahim; Harun, Nurul Hikmah; Septama, Abdi Wira; Murad, Shahnaz; Mesaik, M A

    2011-04-01

    The methanol extracts of 20 selected medicinal plants were investigated for their effects on the respiratory burst of human whole blood, isolated human polymorphonuclear leukocytes (PMNs) and isolated mice macrophages using a luminol/lucigenin-based chemiluminescence assay. We also tested the effect of the extracts on chemotactic migration of PMNs using the Boyden chamber technique. The extracts of Curcuma domestica L., Phyllanthus amarus Schum & Thonn and C. xanthorrhiza Roxb. were the samples producing the strongest oxidative burst of PMNs with luminol-based chemiluminescence, with IC(50) values ranging from 0.5 to 0.7 μg/ml. For macrophage cells, the extracts which showed strong suppressive activity for luminol-based chemiluminescence were C. xanthorrhiza and Garcinia mangostana L. Among the extracts studied, C. mangga Valton & Vazsjip, Piper nigrum L. and Labisia pumila var. alata showed strong inhibitory activity on lucigenin-amplified oxidative burst of PMNs, with IC(50) values ranging from 0.9 to 1.5 μg/ml. The extracts of Zingiber officinale Rosc., Alpinia galangal (L.) Willd and Averrhoa bilimbi Linn showed strong inhibition on the chemotaxic migration of cells, with IC(50) values comparable to that of ibuprofen (1.5 μg/ml). The results suggest that some of these plants were able to modulate the innate immune response of phagocytes at different steps, emphasizing their potential as a source of new immunomodulatory agents.

  8. Biocompatibility assessment of peritoneal dialysis solutions with a new in vitro model of preconditioned human HL60 cells.

    PubMed

    Koball, Sebastian; Korten, Gero; Stange, Jan; Schmidt, Reinhard; Mitzner, Steffen

    2009-07-01

    The purposes of this study were to test the human promyelocytic cell line HL60 for its usability as a new cell model for the immune barrier of the peritoneum, and to investigate the impact of different peritoneal dialysis (PD) solutions in the model. HL60 cells were stimulated by retinoic acid and recombinant human granulocyte and macrophage colony-stimulating factor to differentiate into neutrophilic granulocytes. Cells were incubated in different commercially available PD solutions. After a 4-h incubation, functional (chemiluminescence phagocytosis) and viability tests (Live-Dead, XTT) were performed. High glucose concentrations (>1.36%) and low pH values (<7.0) appeared to be detrimental for neutrophil functions and for neutrophil viability. There is a quantitative correlation between glucose concentration and the cytotoxicity of standard PD solutions (PD 1.36% glucose shows 42.6% higher chemiluminescence than PD 3.86% glucose [P < 0.05]). PD solution containing icodextrin shows 74.3% higher chemiluminescence than PD 3.86% glucose, and PD solution with amino acids shows 52.4% higher chemiluminescence than PD 3.86% glucose which is a sign for better biocompatibility in these tests (P < 0.05). The test system is useful for biocompatibility investigations of PD solutions and their effect on immune cells, for example, neutrophil granulocytes. It does not depend on donor variability and availability in comparison to models based on primary isolated leukocytes.

  9. Effects of in vitro lactoferricin and lactoferrin on the head kidney cells of European sea bass (Dicentrarchus labrax, L.).

    PubMed

    Henry, Morgane A; Alexis, Maria N

    2009-08-15

    Antimicrobial, anti-inflammatory and immunomodulating properties of lactoferrin have been demonstrated in mammals and in fish. However, in vivo, lactoferrin is digested by gastric pepsin treatment into the N-terminal derived peptide named lactoferricin. This has been so far overlooked in fish in vitro studies. The aim of the present study was to assess in vitro the effects of both lactoferricin and lactoferrin on the head kidney cells of European sea bass (Dicentrarchus labrax, L.) in order to determine their potential as dietary additives and to get some insight into their mode of action. In vitro lactoferricin decreased significantly the chemiluminescent response of head kidney cells but did not affect the zymosan-triggered chemiluminescence activity. On the other hand, a high concentration of lactoferrin directly stimulated chemiluminescence but reduced the zymosan-triggered chemiluminescence. The bactericidal activity of head kidney cells was also significantly diminished by pre-incubation with lactoferrin in a dose-dependent manner. Although no significant effect of lactoferricin or lactoferrin was evidenced on head kidney cellular viability, absent or negative effect on the priming of respiratory burst activity suggested that care should be taken when using lactoferrin in the diet of sea bass and high doses should be avoided. Hypotheses about the mechanisms of action of lactoferricin and lactoferrin are presented.

  10. Molecularly imprinted polymer based on chemiluminescence imaging for the chiral recognition of dansyl-phenylalanine.

    PubMed

    Wang, Li; Zhang, Zhujun; Huang, Lianggao

    2008-03-01

    A new molecularly imprinted polymer (MIP)-chemiluminescence (CL) imaging detection approach towards chiral recognition of dansyl-phenylalanine (Phe) is presented. The polymer microspheres were synthesized using precipitation polymerization with dansyl-L-Phe as template. Polymer microspheres were immobilized in microtiter plates (96 wells) using poly(vinyl alcohol) (PVA) as glue. The analyte was selectively adsorbed on the MIP microspheres. After washing, the bound fraction was quantified based on peroxyoxalate chemiluminescence (PO-CL) analysis. In the presence of dansyl-Phe, bis(2,4,6-trichlorophenyl)oxalate (TCPO) reacted with hydrogen peroxide (H2O2) to emit chemiluminescence. The signal was detected and quantified with a highly sensitive cooled charge-coupled device (CCD). Influencing factors were investigated and optimized in detail. Control experiments using capillary electrophoresis showed that there was no significant difference between the proposed method and the control method at a confidence level of 95%. The method can perform 96 independent measurements simultaneously in 30 min and the limits of detection (LODs) for dansyl-L-Phe and dansyl-D-Phe were 0.025 micromol L(-1) and 0.075 micromol L(-1) (3sigma), respectively. The relative standard deviation (RSD) for 11 parallel measurements of dansyl-L-Phe (0.78 micromol L(-1)) was 8%. The results show that MIP-based CL imaging can become a useful analytical technology for quick chiral recognition.

  11. Effects of iron and iron chelation in vitro on mucosal oxidant activity in ulcerative colitis.

    PubMed

    Millar, A D; Rampton, D S; Blake, D R

    2000-09-01

    Reactive oxygen species may be pathogenic in ulcerative colitis. Oral iron supplements anecdotally exacerbate inflammatory bowel disease and iron levels are elevated in the inflamed mucosa. Mucosal iron may enhance hydroxyl ion production via Fenton chemistry. Conversely, the iron chelator, desferrioxamine, is reportedly beneficial in Crohn's disease. To assess the in vitro effects of exogenous iron and of iron chelators on the production of reactive oxygen species by colonic biopsies from normal control subjects and patients with ulcerative colitis. Luminol-amplified chemiluminescence was used to measure mucosal reactive oxygen species production both before and after addition in vitro of ferric citrate (100 microM), desferrioxamine (1 mM) and 1,10-phenanthroline (1 mM). Ferric citrate had no effect on the chemiluminescence produced by human colonic mucosa. However, desferrioxamine and phenanthroline reduced chemiluminescence by 47% (n=7, P=0.018) and by 26% (n=10, P=0.005), respectively, in inactive ulcerative colitis, and by 44% (n=9, P=0. 008) and 42% (n=11, P=0.006) in active disease. The lack of effect of ferric citrate suggests that sufficient free iron is already present in inflamed biopsies to drive the Fenton reaction maximally. The effects of desferrioxamine and 1,10-phenanthroline on the chemiluminescence of biopsies from patients with ulcerative colitis suggest that a clinical trial of topical iron chelation in active disease is indicated.

  12. The Use of Mobile, Electrochemical Sensor Nodes for the Measurement of Personal Exposure to Gas-Phase Air Pollutants

    NASA Astrophysics Data System (ADS)

    Stewart, G.; Popoola, O. A.; Mead, M. I.; McKeating, S. J.; Calleja, M.; Hayes, M.; Baron, R. P.; Saffell, J.; Jones, R.

    2012-12-01

    In this paper we describe how low-cost, lightweight devices, which incorporate GPS and GPRS facilities and contain electrochemical sensors for carbon monoxide (CO), nitrogen monoxide (NO) and nitrogen dioxide (NO2), have been used to collect data representative of personal exposure to these important urban air pollutants. E.U. legislation has set target levels for gases thought to have adverse impacts on human health, and consequently led to a need for a more informed air pollution control policy. With many sites in the U.K. and in the rest of the E.U. still failing to meet annual targets for NO2, a need to better understand pollutant sources and behaviour has arisen. Moreover, while traditional chemiluminescence techniques provide precise measurements, the instruments are sparsely populated around urban centres and are thus limited in their ability to account for true personal exposure. Through a series of laboratory and field studies, it has been shown that electrochemical sensor nodes, when configured suitably and after post-processing of data, can provide selective, reproducible measurements, and that the devices have appropriate detection limits (at the low parts-per-billion level), as well as fast enough response times, for urban air quality studies. Both mobile nodes and their static analogues have been deployed with different aims. Static nodes have been used in dense networks in both the urban environment and in the grounds of a major international airport, as described in the partner papers of Mead et al and Bright et al. Mobile units are easily deployed in scalable networks for short-term studies on personal exposure; these studies have been carried out in a wide range of locations including Lagos, Kuala-Lumpur, London and Valencia. Data collected by both mobile and static sensor nodes illustrate the insufficiency of the existing infrastructure in accounting for both the spatial and temporal variability in air pollutants due to road traffic emissions, and thus also the potential insufficiency at quantifying the risks to health in the surrounding area. Recent campaigns with mobile sensor nodes have included attempts to probe the differences in personal exposure to gas-phase air pollutants at different heights of breathing zone and between different methods of transport.

  13. Distortion of liquid film discharging from twin-fluid atomizer

    NASA Astrophysics Data System (ADS)

    Mehring, C.; Sirignano, W. A.

    2001-11-01

    The nonlinear distortion and disintegration of a thin liquid film exiting from a two-dimensional twin-fluid atomizer is analyzed numerically. Pulsed gas jets impacting on both sides of the discharging liquid film at the atomizer exit generate dilational and/or sinuous deformations of the film. Both liquid phase and gas phase are inviscid and incompressible. For the liquid phase the so-called long-wavelength approximation is employed yielding a system of unsteady one-dimensional equations for the planar film. Solution of Laplace's equation for the velocity potential yields the gas-phase velocity field on both sides of the liquid stream. Coupling between both phases is described through kinematic and dynamic boundary conditions at the phase interfaces, and includes the solution of the unsteady Bernoulli equation to determine the gas-phase pressure along the interfaces. Both gas- and liquid-phase equations are solved simultaneously. Solution of Laplace's equation for the gas streams is obtained by means of a boundary-element method. Numerical solutions for the liquid phase use the Lax-Wendroff method with Richtmyer splitting. Sheet distortion resulting from the stagnation pressure of the impacting gas jets and subsequent disturbance amplification due to Kelvin-Helmholtz effects are studied for various combinations of gas-pulse timing, gas-jet impact angles, gas-to-liquid-density ratio, liquid-phase Weber number and gas-jet-to-liquid-jet-momentum ratio. Dilational and sinuous oscillations of the liquid are examined and film pinch-off is predicted.

  14. Study on Enhancement Principle and Stabilization for the Luminol-H2O2-HRP Chemiluminescence System

    PubMed Central

    Yang, Lihua; Jin, Maojun; Du, Pengfei; Chen, Ge; Zhang, Chan; Wang, Jian; Jin, Fen; Shao, Hua; She, Yongxin; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2015-01-01

    A luminol-H2O2-HRP chemiluminescence system with high relative luminescent intensity (RLU) and long stabilization time was investigated. First, the comparative study on the enhancement effect of ten compounds as enhancers to the luminol-H2O2-HRP chemiluminescence system was carried out, and the results showed that 4-(imidazol-1-yl)phenol (4-IMP), 4-iodophenol (4-IOP), 4-bromophenol (4-BOP) and 4-hydroxy-4’-iodobiphenyl (HIOP) had the best performance. Based on the experiment, the four enhancers were dissolved in acetone, acetonitrile, methanol, and dimethylformamide (DMF) with various concentrations, the results indicated that 4-IMP, 4-IOP, 4-BOP and HIOP dissolved in DMF with the concentrations of 0.2%, 3.2%, 1.6% and 3.2% could get the highest RLU values. Subsequently, the influences of pH, ionic strength, HRP, 4-IMP, 4-IOP, 4-BOP, HIOP, H2O2 and luminol on the stabilization of the luminol-H2O2-HRP chemiluminescence system were studied, and we found that pH value, ionic strength, 4-IMP, 4-IOP, 4-BOP, HIOP, H2O2 and luminol have little influence on luminescent stabilization, while HRP has a great influence. In different ranges of HRP concentration, different enhancers should be selected. When the concentration is within the range of 0~6 ng/mL, 4-IMP should be selected. When the concentration of HRP ranges from 6 to 25ng/mL, 4-IOP was the best choice. And when the concentration is within the range of 25~80 ng/mL, HIOP should be selected as the enhancer. Finally, the three well-performing chemiluminescent enhanced solutions (CESs) have been further optimized according to the three enhancers (4-IMP, 4-IOP and HIOP) in their utilized HRP concentration ranges. PMID:26154162

  15. Donor/acceptor nanoparticle pair-based singlet oxygen channeling homogenous chemiluminescence immunoassay for quantitative determination of bisphenol A.

    PubMed

    Hou, Changjiang; Zhao, Lixia; Geng, Fanglan; Wang, Dan; Guo, Liang-Hong

    2016-12-01

    Bisphenol A (BPA) is widely used in consumer products such as plastic bottles and food containers. It has become a ubiquitous environmental contaminant and poses a serious risk to human health. A rapid, sensitive, and high-throughput method for detecting BPA is therefore desirable. Herein, a donor/acceptor nanoparticle pair-based singlet oxygen channeling chemiluminescence homogenous immunoassay is developed for the determination of BPA. The donor nanoparticles were modified with phthalocyanine as a photosensitizer and were then coated with streptavidin. The acceptor nanoparticles were doped with thioxene derivatives and Eu(III) as a chemiluminescence emitter and then coated with anti-BPA antibody. Under light irradiation, oxygen near the donor surface transforms to singlet oxygen ( 1 O 2 ), which migrates to the acceptor and reacts with it, generating luminescence. Because 1 O 2 has a very short lifetime, luminescence is generated only when the donor and acceptor are in close proximity. This occurs when they are brought together by the antigen/antibody and streptavidin/biotin reaction. Based on this singlet oxygen channeling mechanism, a competitive homogenous chemiluminescence immunoassay for BPA was developed on 384 microplates. The assay exhibited linear detection over the range 10-1000 ng/mL and a limit of detection of 2.9 ng/mL. The intra- and inter-assay precisions were both below 5.1 %. The average recoveries of three spiked samples in tap and river water samples were in the range 95.5-121.0 %, in agreement with values obtained using high-performance liquid chromatography. The homogeneous assay is rapid, low cost, sensitive, and allows high-throughput, so is well suited for screening large numbers of environmental samples. Graphical abstract Principle of the singlet oxygen channeling homogenous chemiluminescence competitive immunoassay based on nanoparticle pairs for determination of BPA.

  16. Study on Enhancement Principle and Stabilization for the Luminol-H2O2-HRP Chemiluminescence System.

    PubMed

    Yang, Lihua; Jin, Maojun; Du, Pengfei; Chen, Ge; Zhang, Chan; Wang, Jian; Jin, Fen; Shao, Hua; She, Yongxin; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2015-01-01

    A luminol-H2O2-HRP chemiluminescence system with high relative luminescent intensity (RLU) and long stabilization time was investigated. First, the comparative study on the enhancement effect of ten compounds as enhancers to the luminol-H2O2-HRP chemiluminescence system was carried out, and the results showed that 4-(imidazol-1-yl)phenol (4-IMP), 4-iodophenol (4-IOP), 4-bromophenol (4-BOP) and 4-hydroxy-4'-iodobiphenyl (HIOP) had the best performance. Based on the experiment, the four enhancers were dissolved in acetone, acetonitrile, methanol, and dimethylformamide (DMF) with various concentrations, the results indicated that 4-IMP, 4-IOP, 4-BOP and HIOP dissolved in DMF with the concentrations of 0.2%, 3.2%, 1.6% and 3.2% could get the highest RLU values. Subsequently, the influences of pH, ionic strength, HRP, 4-IMP, 4-IOP, 4-BOP, HIOP, H2O2 and luminol on the stabilization of the luminol-H2O2-HRP chemiluminescence system were studied, and we found that pH value, ionic strength, 4-IMP, 4-IOP, 4-BOP, HIOP, H2O2 and luminol have little influence on luminescent stabilization, while HRP has a great influence. In different ranges of HRP concentration, different enhancers should be selected. When the concentration is within the range of 0~6 ng/mL, 4-IMP should be selected. When the concentration of HRP ranges from 6 to 25 ng/mL, 4-IOP was the best choice. And when the concentration is within the range of 25~80 ng/mL, HIOP should be selected as the enhancer. Finally, the three well-performing chemiluminescent enhanced solutions (CESs) have been further optimized according to the three enhancers (4-IMP, 4-IOP and HIOP) in their utilized HRP concentration ranges.

  17. [The criterion prognostic significance of examinations of chemiluminescence of oral fluid under impact of chemical pollutants of manufacture of rubber and rubber technical production].

    PubMed

    Galiullina, E F; Valiev, A v; Kamilov, R F; Shakirov, D F; Buliakov, P T

    2013-12-01

    The article presents the results of studies concerning the effect of unfavorable factors of chemical nature on fluid of oral cavity among workers of the Ufa plant of elastomer materials, articles and structures. It is established that in persons contacting with chemical pollutants of manufacture of rubber and rubber technical production the indicators of chemiluminescence of saliva fluid are significantly expressed and depend on professional standing.

  18. Synthesis of dendritic platinum nanoparticles/lucigenin/reduced graphene oxide hybrid with chemiluminescence activity.

    PubMed

    He, Yi; Cui, Hua

    2012-04-16

    Multifunctional hybrid: A dendritic platinum nanoparticle/lucigenin/reduced graphene oxide (RGO) hybrid with chemiluminescence (CL) activity was prepared for the first time by using lucigenin as a linker through simultaneous reduction of H(2) PtCl(4) and a lucigenin-functionalized graphene oxide composite by sodium borohydride (see scheme). The hybrid may have potential applications as a CL sensor, in catalysis, energy conversion, and opto-electronic systems. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Ultrafine particles and nitrogen oxides generated by gas and electric cooking

    PubMed Central

    Dennekamp, M; Howarth, S; Dick, C; Cherrie, J; Donaldson, K; Seaton, A

    2001-01-01

    OBJECTIVES—To measure the concentrations of particles less than 100 nm diameter and of oxides of nitrogen generated by cooking with gas and electricity, to comment on possible hazards to health in poorly ventilated kitchens.
METHODS—Experiments with gas and electric rings, grills, and ovens were used to compare different cooking procedures. Nitrogen oxides (NOx) were measured by a chemiluminescent ML9841A NOx analyser. A TSI 3934 scanning mobility particle sizer was used to measure average number concentration and size distribution of aerosols in the size range 10-500 nm.
RESULTS—High concentrations of particles are generated by gas combustion, by frying, and by cooking of fatty foods. Electric rings and grills may also generate particles from their surfaces. In experiments where gas burning was the most important source of particles, most particles were in the size range 15-40 nm. When bacon was fried on the gas or electric rings the particles were of larger diameter, in the size range 50-100 nm. The smaller particles generated during experiments grew in size with time because of coagulation. Substantial concentrations of NOX were generated during cooking on gas; four rings for 15 minutes produced 5 minute peaks of about 1000 ppb nitrogen dioxide and about 2000 ppb nitric oxide.
CONCLUSIONS—Cooking in a poorly ventilated kitchen may give rise to potentially toxic concentrations of numbers of particles. Very high concentrations of oxides of nitrogen may also be generated by gas cooking, and with no extraction and poor ventilation, may reach concentrations at which adverse health effects may be expected. Although respiratory effects of exposure to NOx might be anticipated, recent epidemiology suggests that cardiac effects cannot be excluded, and further investigation of this is desirable.


Keywords: cooking fuels; nitrogen oxides; ultrafine particles PMID:11452045

  20. Schlieren optical visualization for transient EHD induced flow in a stratified dielectric liquid under gas-phase ac corona discharges

    NASA Astrophysics Data System (ADS)

    Ohyama, R.; Inoue, K.; Chang, J. S.

    2007-01-01

    A flow pattern characterization of electrohydrodynamically (EHD) induced flow phenomena of a stratified dielectric fluid situated in an ac corona discharge field is conducted by a Schlieren optical system. A high voltage application to a needle-plate electrode arrangement in gas-phase normally initiates a conductive type EHD gas flow. Although the EHD gas flow motion initiated from the corona discharge electrode has been well known as corona wind, no comprehensive study has been conducted for an EHD fluid flow motion of the stratified dielectric liquid that is exposed to the gas-phase ac corona discharge. The experimentally observed result clearly presents the liquid-phase EHD flow phenomenon induced from the gas-phase EHD flow via an interfacial momentum transfer. The flow phenomenon is also discussed in terms of the gas-phase EHD number under the reduced gas pressure (reduced interfacial momentum transfer) conditions.

  1. Multiphase flow and transport caused by spontaneous gas phase growth in the presence of dense non-aqueous phase liquid

    NASA Astrophysics Data System (ADS)

    Roy, James W.; Smith, James E.

    2007-01-01

    Disconnected bubbles or ganglia of trapped gas may occur below the top of the capillary fringe through a number of mechanisms. In the presence of dense non-aqueous phase liquid (DNAPL), the disconnected gas phase experiences mass transfer of dissolved gases, including volatile components from the DNAPL. The properties of the gas phase interface can also change. This work shows for the first time that when seed gas bubbles exist spontaneous gas phase growth can be expected to occur and can significantly affect water-gas-DNAPL distributions, fluid flow, and mass transfer. Source zone behaviour was observed in three different experiments performed in a 2-dimensional flow cell. In each case, a DNAPL pool was created in a zone of larger glass beads over smaller glass beads, which served as a capillary barrier. In one experiment effluent water samples were analyzed to determine the vertical concentration profile of the plume above the pool. The experiments effectively demonstrated a) a cycle of spontaneous gas phase expansion and vertical advective mobilization of gas bubbles and ganglia above the DNAPL source zone, b) DNAPL redistribution caused by gas phase growth and mobilization, and c) that these processes can significantly affect mass transport from a NAPL source zone.

  2. Multiphase flow and transport caused by spontaneous gas phase growth in the presence of dense non-aqueous phase liquid.

    PubMed

    Roy, James W; Smith, James E

    2007-01-30

    Disconnected bubbles or ganglia of trapped gas may occur below the top of the capillary fringe through a number of mechanisms. In the presence of dense non-aqueous phase liquid (DNAPL), the disconnected gas phase experiences mass transfer of dissolved gases, including volatile components from the DNAPL. The properties of the gas phase interface can also change. This work shows for the first time that when seed gas bubbles exist spontaneous gas phase growth can be expected to occur and can significantly affect water-gas-DNAPL distributions, fluid flow, and mass transfer. Source zone behaviour was observed in three different experiments performed in a 2-dimensional flow cell. In each case, a DNAPL pool was created in a zone of larger glass beads over smaller glass beads, which served as a capillary barrier. In one experiment effluent water samples were analyzed to determine the vertical concentration profile of the plume above the pool. The experiments effectively demonstrated a) a cycle of spontaneous gas phase expansion and vertical advective mobilization of gas bubbles and ganglia above the DNAPL source zone, b) DNAPL redistribution caused by gas phase growth and mobilization, and c) that these processes can significantly affect mass transport from a NAPL source zone.

  3. Simple setup for gas-phase H/D exchange mass spectrometry coupled to electron transfer dissociation and ion mobility for analysis of polypeptide structure on a liquid chromatographic time scale.

    PubMed

    Mistarz, Ulrik H; Brown, Jeffery M; Haselmann, Kim F; Rand, Kasper D

    2014-12-02

    Gas-phase hydrogen/deuterium exchange (HDX) is a fast and sensitive, yet unharnessed analytical approach for providing information on the structural properties of biomolecules, in a complementary manner to mass analysis. Here, we describe a simple setup for ND3-mediated millisecond gas-phase HDX inside a mass spectrometer immediately after ESI (gas-phase HDX-MS) and show utility for studying the primary and higher-order structure of peptides and proteins. HDX was achieved by passing N2-gas through a container filled with aqueous deuterated ammonia reagent (ND3/D2O) and admitting the saturated gas immediately upstream or downstream of the primary skimmer cone. The approach was implemented on three commercially available mass spectrometers and required no or minor fully reversible reconfiguration of gas-inlets of the ion source. Results from gas-phase HDX-MS of peptides using the aqueous ND3/D2O as HDX reagent indicate that labeling is facilitated exclusively through gaseous ND3, yielding similar results to the infusion of purified ND3-gas, while circumventing the complications associated with the use of hazardous purified gases. Comparison of the solution-phase- and gas-phase deuterium uptake of Leu-Enkephalin and Glu-Fibrinopeptide B, confirmed that this gas-phase HDX-MS approach allows for labeling of sites (heteroatom-bound non-amide hydrogens located on side-chains, N-terminus and C-terminus) not accessed by classical solution-phase HDX-MS. The simple setup is compatible with liquid chromatography and a chip-based automated nanoESI interface, allowing for online gas-phase HDX-MS analysis of peptides and proteins separated on a liquid chromatographic time scale at increased throughput. Furthermore, online gas-phase HDX-MS could be performed in tandem with ion mobility separation or electron transfer dissociation, thus enabling multiple orthogonal analyses of the structural properties of peptides and proteins in a single automated LC-MS workflow.

  4. Dramatically different kinetics and mechanism at solid/liquid and solid/gas interfaces for catalytic isopropanol oxidation over size-controlled platinum nanoparticles.

    PubMed

    Wang, Hailiang; Sapi, Andras; Thompson, Christopher M; Liu, Fudong; Zherebetskyy, Danylo; Krier, James M; Carl, Lindsay M; Cai, Xiaojun; Wang, Lin-Wang; Somorjai, Gabor A

    2014-07-23

    We synthesize platinum nanoparticles with controlled average sizes of 2, 4, 6, and 8 nm and use them as model catalysts to study isopropanol oxidation to acetone in both the liquid and gas phases at 60 °C. The reaction at the solid/liquid interface is 2 orders of magnitude slower than that at the solid/gas interface, while catalytic activity increases with the size of platinum nanoparticles for both the liquid-phase and gas-phase reactions. The activation energy of the gas-phase reaction decreases with the platinum nanoparticle size and is in general much higher than that of the liquid-phase reaction which is largely insensitive to the size of catalyst nanoparticles. Water substantially promotes isopropanol oxidation in the liquid phase. However, it inhibits the reaction in the gas phase. The kinetic results suggest different mechanisms between the liquid-phase and gas-phase reactions, correlating well with different orientations of IPA species at the solid/liquid interface vs the solid/gas interface as probed by sum frequency generation vibrational spectroscopy under reaction conditions and simulated by computational calculations.

  5. Method and system for measuring multiphase flow using multiple pressure differentials

    DOEpatents

    Fincke, James R.

    2001-01-01

    An improved method and system for measuring a multiphase flow in a pressure flow meter. An extended throat venturi is used and pressure of the multiphase flow is measured at three or more positions in the venturi, which define two or more pressure differentials in the flow conduit. The differential pressures are then used to calculate the mass flow of the gas phase, the total mass flow, and the liquid phase. The method for determining the mass flow of the high void fraction fluid flow and the gas flow includes certain steps. The first step is calculating a gas density for the gas flow. The next two steps are finding a normalized gas mass flow rate through the venturi and computing a gas mass flow rate. The following step is estimating the gas velocity in the venturi tube throat. The next step is calculating the pressure drop experienced by the gas-phase due to work performed by the gas phase in accelerating the liquid phase between the upstream pressure measuring point and the pressure measuring point in the venturi throat. Another step is estimating the liquid velocity in the venturi throat using the calculated pressure drop experienced by the gas-phase due to work performed by the gas phase. Then the friction is computed between the liquid phase and a wall in the venturi tube. Finally, the total mass flow rate based on measured pressure in the venturi throat is calculated, and the mass flow rate of the liquid phase is calculated from the difference of the total mass flow rate and the gas mass flow rate.

  6. Electron impact contribution to infrared NO emissions in auroral conditions

    NASA Astrophysics Data System (ADS)

    Campbell, L.; Brunger, M. J.

    2007-11-01

    Infrared emissions from nitric oxide, other than nightglow, are observed in aurora, principally due to a chemiluminescent reaction between excited nitrogen atoms and oxygen molecules that produces vibrationally excited NO. The rates for this chemiluminescent reaction have recently been revised. Based on new measurements of electron impact vibrational excitation of NO, it has been suggested that electron impact may also be significant in producing auroral NO emissions. We show results of a detailed calculation which predicts the infrared spectrum observed in rocket measurements, using the revised chemiluminescent rates and including electron impact excitation. For emissions from the second vibrational level and above, the shape of the spectrum can be reproduced within the statistical errors of the analysis of the measurements, although there is an unexplained discrepancy in the absolute value of the emissions. The inclusion of electron impact improves the agreement of the shape of the predicted spectrum with the measurements by accounting for part of the previously unexplained peak in emissions from the first vibrational level.

  7. Flow-injection chemiluminescence determination of diazepam by oxidation with N-bromosuccinimide.

    PubMed

    Han, Suqin; Jia, Shize; Guo, Liang

    2013-01-01

    A rapid and sensitive flow-injection chemiluminescence (FI-CL) method is described for the determination of diazepam based on its reaction with N-bromosuccinimide (NBS) in alkaline medium in the presence of dichlorofluorescein (DCF) as an effective energy-transfer agent. Under optimum conditions, the proposed method allowed the measurement of diazepam over the range of 2.0 × 10(-6) to 2.0 × 10(-4) mol/L with a detection limit of 5.0 × 10(-7) mol/L. The relative standard deviation for 11 parallel measurements of 2.0 × 10(-5) mol/L diazepam was 2.1%. The method was applied satisfactorily for the determination of diazepam in pharmaceutical preparations, and the results agree well with those obtained by spectrophotometry. The use of the proposed system for the determination of diazepam in urine and plasma samples was also tested. The possible mechanism of the chemiluminescence reaction is discussed briefly. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Flame structure of methane/oxygen shear coaxial jet with velocity ratio using high-speed imaging and OH*, CH* chemiluminescence

    NASA Astrophysics Data System (ADS)

    Shim, Myungbo; Noh, Kwanyoung; Yoon, Woongsup

    2018-06-01

    In this study, the effects of gaseous methane/oxygen injection velocity ratio on the shear coaxial jet flame structure are analyzed using high-speed imaging along with OH* and CH* chemiluminescence. The images show that, as the velocity ratio is increased, the visual flame length increases and wrinkles of the flame front are developed further downstream. The region near the equivalence ratio 1 condition in the flame could be identified by the maximum OH* position, and this region is located further downstream as the velocity ratio is increased. The dominant CH* chemiluminescence is found in the near-injector region. As the velocity ratio is decreased, the signal intensity is higher at the same downstream distance in each flame. From the results, as the velocity ratio is decreased, there is increased entrainment of the external jet, the mixing of the two jets is enhanced, the region near the stoichiometric mixture condition is located further upstream, and consequently, the flame length decreases.

  9. Experimental investigation of the unsteady response of premixed flame fronts to acoustic pressure waves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wangher, Athena; Searby, Geoff; Quinard, Joel

    Using OH{sup *} chemiluminescence, we measure the experimental unsteady response of a 1-D premixed flame to an acoustic pressure wave for a range of frequencies below and above the inverse of the flame transit time. We find that the response is positive and, at low frequency, the order of magnitude is comparable with existing theoretical analyses. However, if it is assumed that the chemiluminescence is proportional to the mass consumption rate, despite some uncertainty in the interpretation of the chemiluminescence signal we find that the frequency dependence of the measured response is not compatible with the predictions of the standardmore » flame model for one-step Arrhenius kinetics. A better, but not perfect, correlation is obtained for the heat release rate. We conclude that the standard model does not provide an adequate description of the unsteady response of real flames and that it is necessary to investigate more realistic chemical models. (author)« less

  10. [Photosensitization and photoprotection by some drugs, metabolites and other compounds].

    PubMed

    Lozovskaia, E L; Makareeva, E N; Makedonov, I U

    1997-01-01

    Photosensitizing and photoprotecting efficiency of about a hundred of compounds, mainly drugs, was studied. The method based on chemiluminescence occurred along with photooxidation of glycyltryptophan under irradiation in UVB range in solution was used for testing. As a measure of photosensitizing efficiency the concentration of photosensitizer which induced two-fold increase of chemiluminescence intensity was chosen. The most effective photosensitizers are riboflavin, FAD, furagin, psoralene, vicasol, benzobarbital, mydocalm, angelicyn, furadonin, ethacridin, diazolin, folic acid. With regard to pharmacological doses of drugs in organism more dangerous sensitizers (in descending order) are p-aminosalicylic acid, furagin, riboflavin, benzobarbital, thiopental, chloramphenicol, nicodin, mydocalm, furadonin, oxolonic acid, furazolidone, psoralene, nicotinamide and diazolin. Photoprotecting effect was described by the concentration at which chemiluminescence intensity decreased twice. The most effective photoprotectors are etamsilat, quercetin, ftivazid, chlorpromazine, diprazine, thioridazine, aminophenazone, oxaphenamide. Concentration dependence for some of these drugs (etamsilat, chlorpromazine, diprazine, thioridazine) is non-monotonous: they inhibit photooxidation in low concentration (about 10(-7)-10(-6) M), but at higher concentrations (10(-5)-10(-4) M) photosensitization dominates over photoprotection.

  11. Chemiluminescence reactions with cationic, neutral, and anionic ruthenium(II) complexes containing 2,2'-bipyridine and bathophenanthroline disulfonate ligands.

    PubMed

    Francis, Paul S; Papettas, Dimitra; Zammit, Elizabeth M; Barnett, Neil W

    2010-07-15

    Ruthenium complexes containing 4,7-diphenyl-1,10-phenanthroline disulfonate (bathophenanthroline disulfonate; BPS) ligands, Ru(BPS)(3)(4-), Ru(BPS)(2)(bipy)(2-) and Ru(BPS)(bipy)(2), were compared to tris(2,2'-bipyridine)ruthenium(II) (Ru(bipy)(3)(2+)), including examination of the wavelengths of maximum absorption and corrected emission intensity, photoluminescence quantum yield, stability of their oxidised ruthenium(III) form, and relative chemiluminescence intensities and signal-to-blank ratios with cerium(IV) sulfate and six analytes (codeine, morphine cocaine, potassium oxalate, furosemide and hydrochlorothiazide) in acidic aqueous solution. The presence of BPS ligands in the complex increased the photoluminescence quantum yield, but decreased the stability of the oxidised form of the reagent. In contrast to previous evidence showing much greater electrochemiluminescence intensities using Ru(BPS)(2)(bipy)(2-) and Ru(BPS)(bipy)(2), these complexes did not provide superior chemiluminescence signals than their homoleptic analogues. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Rapid method for monitoring N-nitrosodimethylamine in drinking water at the ng/L level without pre-concentration using high-performance liquid chromatography-chemiluminescence detection.

    PubMed

    Kodamatani, Hitoshi; Yamasaki, Hitomi; Sakaguchi, Takeru; Itoh, Shinya; Iwaya, Yoshimi; Saga, Makoto; Saito, Keiitsu; Kanzaki, Ryo; Tomiyasu, Takashi

    2016-08-19

    As a contaminant in drinking water, N-nitrosodimethylamine (NDMA) is of great concern because of its carcinogenicity; it has been limited to levels of ng/L by regulatory bodies worldwide. Consequently, a rapid and sensitive method for monitoring NDMA in drinking water is urgently required. In this study, we report an improvement of our previously proposed HPLC-based system for NDMA determination. The approach consists of the HPLC separation of NDMA, followed by NDMA photolysis to form peroxynitrite and detection with a luminol chemiluminescence reaction. The detection limit for the improved HPLC method was 0.2ng/L, which is 10 times more sensitive than our previously reported system. For tap water measurements, only the addition of an ascorbic acid solution to eliminate residual chlorine and passage through an Oasis MAX solid-phase extraction cartridge are needed. The proposed NDMA determination method requires a sample volume of less than 2mL and a complete analysis time of less than 15min per sample. The method was utilized for the long-term monitoring of NDMA in tap water. The NDMA level measured in the municipal water survey was 4.9ng/L, and a seasonal change of the NDMA concentration in tap water was confirmed. The proposed method should constitute a useful NDMA monitoring method for protecting drinking water quality. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Giddings Austin chalk enters deep lean-gas phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moritis, G.

    1995-12-25

    Deep lean gas is the latest phase in the growth of the Giddings field Austin chalk play. The first phase involved drilling vertical oil and gas wells. Next came the horizontal well boom in the shallower Austin chalk area, which is still continuing. And now this third phase places horizontal laterals in the Austen chalk at about 14,000--15,000 ft to produce lean gas. The article describes the producing wells and gas gathering.

  14. Chemiluminescence-based pesticide biosensor utilizing the intelligent evolved properties of the enzyme alkaline phosphatase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayyagari, M.; Kamtekar, S.; Pande, R.

    A methodology is described for immobilizing the enzyme alkaline phosphatase onto a glass surface using a novel biotinylated copolymer, poly(3-undecylthiophene-co-3- methanoithiophene). A streptavidin conjugate of alkaline phosphatase is used in this study. The biotinylated polymer is attached to the silanized glass surface via hydrophobic interactions and the enzyme is interfaced with the polymer through the classical biotin- streptavidin interaction. Alkaline phosphatase catalyzes the dephosphorylation of a macrocyclic compound, chloro-3-(4-methoxy spiro) (1,2 dioxetane-3-2`-tricyclo-) (3.3.1.1 )-(decani-4-yl) phenyl phosphate, to a species which emits energy by chemiluminescence. This chemiluminescence signal can be detected with a photomultiplier tube for enzymatic catalysis with the biocatalystmore » both in solution and immobilized on a glass surface. The signal generation is inhibited by the organophosphorus based insecticides such as paraoxon as well as nerve agents. We demonstrate in this study that a number of organophosphorus based insecticides inhibit the enzyme-mediated generation of chemiluminescence signal. This is true for the enzyme conjugate both free in solution and immobilized on a glass surface. In solution, the inhibition resembles the case of a partially uncompetitive system. By this type of inhibition we are able to detect pesticides down to about 50 ppb for the enzyme in solution. The pesticide detection limit of immobilized enzyme is currently being investigated. The enzyme is capable of a number of measurement cycles without significant loss of signal level.« less

  15. Chemiluminescence of BO{sub 2} to map the creation of thermal NO in flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maligne, D.; Cessou, A.; Stepowski, D.

    The aim of this study is to detect and map the local conditions that generate thermal NO in flames. According to the Zeldovich mechanism, the formation of NO comes from the local conjunction of a high concentration of atomic oxygen and a temperature above a critical high level imposed by the high activation energy of the rate-limiting reaction. The green light emitted when a flame is seeded with boron salts is a chemiluminescence from the BO{sup *}{sub 2} that is chemically formed in its excited state when BO reacts with atomic oxygen. As the rate of this oxidation is alsomore » strongly increasing with temperature, the chemiluminescence of BO{sub 2} depends on the concentration of atomic oxygen and on the temperature in a way similar to the formation rate of thermal NO. This double analogy suggests the possibility of an experimental in situ simulation of the formation rate of thermal NO or at least the use of the chemiluminescence of BO{sub 2} to map the sites where thermal NO is being created. Spectroscopic experiments and comparisons with numerical simulations have been performed to test the feasibility of this technique in laminar premixed and diffusion methane/air flames. The agreement is good except in the burnt gases of fuel-rich flames. Imaging strategies with different spectral filters have been developed in the same flames to overcome the problem of interference from soot radiation in diffusion flames. (author)« less

  16. Cu2+ -Modified Metal-Organic Framework Nanoparticles: A Peroxidase-Mimicking Nanoenzyme.

    PubMed

    Chen, Wei-Hai; Vázquez-González, Margarita; Kozell, Anna; Cecconello, Alessandro; Willner, Itamar

    2018-02-01

    The synthesis and characterization of UiO-type metal-organic framework nanoparticles (NMOFs) composed of Zr 4+ ions bridged by 2,2'-bipyridine-5,5'-dicarboxylic acid ligands and the postmodification of the NMOFs with Cu 2+ ions are described. The resulting Cu 2+ -modified NMOFs, Cu 2+ -NMOFs, exhibit peroxidase-like catalytic activities reflected by the catalyzed oxidation of Amplex-Red to the fluorescent Resorufin by H 2 O 2 , the catalyzed oxidation of dopamine to aminochrome by H 2 O 2 , and the catalyzed generation of chemiluminescence in the presence of luminol/H 2 O 2 . Also, the Cu 2+ -NMOFs mimic NADH peroxidase functions and catalyze the oxidation of dihydronicotinamide adenine dinucleotide, NADH, to nicotinamide adenine dinucleotide, NAD + , in the presence of H 2 O 2 . The Cu 2+ -NMOFs-catalyzed generation of chemiluminescence in the presence of luminol/H 2 O 2 is used to develop a glucose sensor by monitoring the H 2 O 2 formed by the aerobic oxidation of glucose to gluconic acid in the presence of glucose oxidase. Furthermore, loading the Cu 2+ -NMOFs with fluorescein and activating the catalyzed generation of chemiluminescence in the presence of luminol/H 2 O 2 yield an efficient chemiluminescence resonance energy transfer (CRET) process to the fluorescein reflected by the activation of the fluorescence of the dye (λ = 520 nm, CRET efficiency 35%). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A novel polydopamine-based chemiluminescence resonance energy transfer method for microRNA detection coupling duplex-specific nuclease-aided target recycling strategy.

    PubMed

    Wang, Qian; Yin, Bin-Cheng; Ye, Bang-Ce

    2016-06-15

    MicroRNAs (miRNAs), functioning as oncogenes or tumor suppressors, play significant regulatory roles in regulating gene expression and become as biomarkers for disease diagnostics and therapeutics. In this work, we have coupled a polydopamine (PDA) nanosphere-assisted chemiluminescence resonance energy transfer (CRET) platform and a duplex-specific nuclease (DSN)-assisted signal amplification strategy to develop a novel method for specific miRNA detection. With the assistance of hemin, luminol, and H2O2, the horseradish peroxidase (HRP)-mimicking G-rich sequence in the sensing probe produces chemiluminescence, which is quickly quenched by the CRET effect between PDA as energy acceptor and excited luminol as energy donor. The target miRNA triggers DSN to partially degrade the sensing probe in the DNA-miRNA heteroduplex to repeatedly release G-quadruplex formed by G-rich sequence from PDA for the production of chemiluminescence. The method allows quantitative detection of target miRNA in the range of 80 pM-50 nM with a detection limit of 49.6 pM. The method also shows excellent specificity to discriminate single-base differences, and can accurately quantify miRNA in biological samples, with good agreement with the result from a commercial miRNA detection kit. The procedure requires no organic dyes or labels, and is a simple and cost-effective method for miRNA detection for early clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Simultaneous titration and phenotypic antiviral drug susceptibility testing for herpes simplex virus 1 and 2.

    PubMed

    Tardif, Keith D; Jorgensen, Shane; Langer, Janine; Prichard, Mark; Schlaberg, Robert

    2014-11-01

    Most herpes simplex virus (HSV) isolates from treatment-naïve patients are susceptible to antivirals. However, prolonged antiviral therapy can select for drug-resistant strains, especially in immunocompromised patients. Standard phenotypic methods for antiviral resistance testing are labor and time-intense and molecular resistance determinants are insufficiently understood for routine diagnostic use of genotypic resistance testing. To enable rapid, scalable antiviral susceptibility testing and minimize viral passage, we developed a 7-day, 96-well assay for simultaneous HSV 1/2 titration and phenotypic resistance testing for acyclovir and foscarnet. The assay was optimized and validated by testing clinical isolates and laboratory strains (n=39) with known IC50 for acyclovir (23 resistant) and foscarnet (1 resistant) based on plaque reduction or dye-uptake assays. A chemiluminescent detection reagent is used for quantification of cytopathic effect instead of plaque counting or measuring dye-uptake. Drug concentrations inhibiting 50% of chemiluminescent signal reduction (IC50) were determined concurrently at each of three virus dilutions. Results agree for 92.3% (acyclovir) and 100% (foscarnet) of isolates. For all three discordant samples, results of reference testing by plaque reduction agreed with the chemiluminescent assay. Reproducibility studies showed 100% qualitative agreement and 3-37% coefficient of variation based on IC50. Chemiluminescence detection as a surrogate for cellular viability with an automated plate reader provides improved throughput and workflow, as well as high accuracy and reproducibility for antiviral drug susceptibility testing. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Numerical Computation of Flame Spread over a Thin Solid in Forced Concurrent Flow with Gas-phase Radiation

    NASA Technical Reports Server (NTRS)

    Jiang, Ching-Biau; T'ien, James S.

    1994-01-01

    Excerpts from a paper describing the numerical examination of concurrent-flow flame spread over a thin solid in purely forced flow with gas-phase radiation are presented. The computational model solves the two-dimensional, elliptic, steady, and laminar conservation equations for mass, momentum, energy, and chemical species. Gas-phase combustion is modeled via a one-step, second order finite rate Arrhenius reaction. Gas-phase radiation considering gray non-scattering medium is solved by a S-N discrete ordinates method. A simplified solid phase treatment assumes a zeroth order pyrolysis relation and includes radiative interaction between the surface and the gas phase.

  20. Pulsed laser photolysis and quantum chemical-statistical rate study of the reaction of the ethynyl radical with water vapor

    NASA Astrophysics Data System (ADS)

    Carl, Shaun A.; Minh Thi Nguyen, Hue; Elsamra, Rehab M. I.; Tho Nguyen, Minh; Peeters, Jozef

    2005-03-01

    The rate coefficient of the gas-phase reaction C2H+H2O→products has been experimentally determined over the temperature range 500-825K using a pulsed laser photolysis-chemiluminescence (PLP-CL) technique. Ethynyl radicals (C2H) were generated by pulsed 193nm photolysis of C2H2 in the presence of H2O vapor and buffer gas N2 at 15Torr. The relative concentration of C2H radicals was monitored as a function of time using a CH * chemiluminescence method. The rate constant determinations for C2H+H2O were k1(550K)=(2.3±1.3)×10-13cm3s-1, k1(770cm3s-1, and k1(825cm3s-1. The error in the only other measurement of this rate constant is also discussed. We have also characterized the reaction theoretically using quantum chemical computations. The relevant portion of the potential energy surface of C2H3O in its doublet electronic ground state has been investigated using density functional theory B3LYP /6-311++G(3df,2p) and molecular orbital computations at the unrestricted coupled-cluster level of theory that incorporates all single and double excitations plus perturbative corrections for the triple excitations, along with the 6-311++G(3df,2p) basis set [(U)CCSD(T)/6-311++G(3df,2p)] and using UCCSD(T )/6-31G(d,p) optimized geometries. Five isomers, six dissociation products, and sixteen transition structures were characterized. The results confirm that the hydrogen abstraction producing C2H2+OH is the most facile reaction channel. For this channel, refined computations using (U)CCSD(T)/6-311++G(3df,2p)//(U)CCSD(T)/6-311++G(d,p) and complete-active-space second-order perturbation theory/complete-active-space self-consistent-field theory (CASPT2/CASSCF) [B. O. Roos, Adv. Chem. Phys. 69, 399 (1987)] using the contracted atomic natural orbitals basis set (ANO-L) [J. Almlöf and P. R. Taylor, J. Chem. Phys.86, 4070 (1987)] were performed, yielding zero-point energy-corrected potential energy barriers of 17kJmol-1 and 15kJmol-1, respectively. Transition-state theory rate constant calculations, based on the UCCSD(T) and CASPT2/CASSCF computations that also include H-atom tunneling and a hindered internal rotation, are in perfect agreement with the experimental values. Considering both our experimental and theoretical determinations, the rate constant can best be expressed, in modified Arrhenius form as k1(T)=(2.2±0.1)×10-21T3.05exp[-(376±100)/T]cm3s-1 for the range 300-2000K. Thus, at temperatures above 1500K, reaction of C2H with H2O is predicted to be one of the dominant C2H reactions in hydrocarbon combustion.

  1. Measurement of Biologically Available Naphthalene in Gas and Aqueous Phases by Use of a Pseudomonas putida Biosensor

    PubMed Central

    Werlen, Christoph; Jaspers, Marco C. M.; van der Meer, Jan Roelof

    2004-01-01

    Genetically constructed microbial biosensors for measuring organic pollutants are mostly applied in aqueous samples. Unfortunately, the detection limit of most biosensors is insufficient to detect pollutants at low but environmentally relevant concentrations. However, organic pollutants with low levels of water solubility often have significant gas-water partitioning coefficients, which in principle makes it possible to measure such compounds in the gas rather than the aqueous phase. Here we describe the first use of a microbial biosensor for measuring organic pollutants directly in the gas phase. For this purpose, we reconstructed a bioluminescent Pseudomonas putida naphthalene biosensor strain to carry the NAH7 plasmid and a chromosomally inserted gene fusion between the sal promoter and the luxAB genes. Specific calibration studies were performed with suspended and filter-immobilized biosensor cells, in aqueous solution and in the gas phase. Gas phase measurements with filter-immobilized biosensor cells in closed flasks, with a naphthalene-contaminated aqueous phase, showed that the biosensor cells can measure naphthalene effectively. The biosensor cells on the filter responded with increasing light output proportional to the naphthalene concentration added to the water phase, even though only a small proportion of the naphthalene was present in the gas phase. In fact, the biosensor cells could concentrate a larger proportion of naphthalene through the gas phase than in the aqueous suspension, probably due to faster transport of naphthalene to the cells in the gas phase. This led to a 10-fold lower detectable aqueous naphthalene concentration (50 nM instead of 0.5 μM). Thus, the use of bacterial biosensors for measuring organic pollutants in the gas phase is a valid method for increasing the sensitivity of these valuable biological devices. PMID:14711624

  2. Airborne Measurements of NOx, NOy, and O3 Using Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Zarzana, K. J.; Wild, R. J.; Thompson, C. R.; Sjostedt, S. J.; Womack, C. C.; Washenfelder, R. A.; Dube, W. P.; Ryerson, T. B.; Brown, S. S.

    2015-12-01

    NO and NO2 (=NOx) have a large effect on air quality and chemistry. Oxidation reactions transform NOx into other reactive nitrogen species such as PAN, HNO3, organic nitrates and N2O5, which can act either as sinks or reservoirs of NOx. Together with NOx, the sum of these oxidized reactive nitrogen species is termed NOy. Ozone serves as a principal oxidant source for many of these reactions, and it is also produced or destroyed during subsequent chemical cycles. Therefore, simultaneous measurements of all four species (NO, NO2, NOy, and O3) are desirable. Previous measurements of these species have principally been made by converting the compound of interest to NO, which is then detected using chemiluminescence. Alternatively, these species can be converted to NO2, which can then be detected using absorption spectroscopy. The use of a cavity ring down instrument allows for the accurate and rapid detection of NO2 in a compact and robust platform suitable for field deployments on numerous platforms, including vehicles and airplanes. In this work we describe the first aircraft deployment of a four-channel cavity ring-down instrument capable of simultaneously measuring NO2, NO, NOy, and O3. This deployment took place during the 2015 Shale Oil and Natural Gas Nexus (SONGNEX) field campaign in the western United States. The instrument flew in tandem with a chemiluminescence instrument, which measured the same set of compounds. A separate instrument that measured NO2 by a related absorption technique, broadband cavity enhanced spectroscopy (BBCES) was also on board the aircraft. An intercomparison between these instruments will be presented, as well as data from the SONGNEX flights that illustrate the capabilities of the CRDS insrument.

  3. A measurement of total reactive nitrogen, NOy, together with NO₂, NO, and O₃ via cavity ring-down spectroscopy.

    PubMed

    Wild, Robert J; Edwards, Peter M; Dubé, William P; Baumann, Karsten; Edgerton, Eric S; Quinn, Patricia K; Roberts, James M; Rollins, Andrew W; Veres, Patrick R; Warneke, Carsten; Williams, Eric J; Yuan, Bin; Brown, Steven S

    2014-08-19

    We present a sensitive, compact detector that measures total reactive nitrogen (NOy), as well as NO2, NO, and O3. In all channels, NO2 is directly detected by laser diode based cavity ring-down spectroscopy (CRDS) at 405 nm. Ambient O3 is converted to NO2 in excess NO for the O3 measurement channel. Likewise, ambient NO is converted to NO2 in excess O3. Ambient NOy is thermally dissociated at ∼700 °C to form NO2 or NO in a heated quartz inlet. Any NO present in ambient air or formed from thermal dissociation of other reactive nitrogen compounds is converted to NO2 in excess O3 after the thermal converter. We measured thermal dissociation profiles for six of the major NOy components and compared ambient measurements with other instruments during field campaigns in Utah and Alabama. Alabama measurements were made in a rural location with high biogenic emissions, and Utah measurements were made in the wintertime in unusual conditions that form high ozone levels from emissions related to oil and gas production. The NOy comparison in Alabama, to an accepted standard measurement method (a molybdenum catalytic converter/chemiluminescence instrument), agreed to within 12%, which we define as an upper limit to the accuracy of the NOy channel. The 1σ precision is <30 pptv at 1 s and <4 pptv at 1 min time resolution for all measurement channels. The accuracy is 3% for the NO2 and O3 channels and 5% for the NO channel. The precision and accuracy of this instrument make it a versatile alternative to standard chemiluminescence-based NOy instruments.

  4. Normal values of offline exhaled and nasal nitric oxide in healthy children and teens using chemiluminescence.

    PubMed

    Menou, A; Babeanu, D; Paruit, H N; Ordureau, A; Guillard, S; Chambellan, A

    2017-08-21

    Nitric oxide (NO) can be used to detect respiratory or ciliary diseases. Fractional exhaled nitric oxide (FeNO) measurement can reflect ongoing eosinophilic airway inflammation and has a diagnostic utility as a test for asthma screening and follow-up while nasal nitric oxide (nNO) is a valuable screening tool for the diagnosis of primary ciliary dyskinesia. The possibility of collecting airway gas samples in an offline manner offers the advantage to extend these measures and improve the screening and management of these diseases, but normal values from healthy children and teens remain sparse. Samples were consecutively collected using the offline method for eNO and nNO chemiluminescence measurement in 88 and 31 healthy children and teens, respectively. Offline eNO measurement was also performed in 30 consecutive children with naïve asthma and/or respiratory allergy. The normal offline eNO value was determined by the following regression equation -8.206 + 0.176 × height. The upper limit of the norm for the offline eNO value was 27.4 parts per billion (ppb). A separate analysis was performed in children, pre-teens and teens, for which offline eNO was 13.6 ± 4.7 ppb, 16.3 ± 13.7 ppb and 20.0 ± 7.2 ppb, respectively. The optimal cut-off value of the offline eNO to predict asthma or respiratory allergies was 23.3 ppb, with a sensitivity and specificity of 77% and 91%, respectively. Mean offline nNO was determined at 660 ppb with the lower limit of the norm at 197 ppb. The use of offline eNO and nNO normal values should favour the widespread screening of respiratory diseases in children of school age in their usual environment.

  5. An Introduction to the Gas Phase

    NASA Astrophysics Data System (ADS)

    Vallance, Claire

    2017-11-01

    'An Introduction to the Gas Phase' is adapted from a set of lecture notes for a core first year lecture course in physical chemistry taught at the University of Oxford. The book is intended to give a relatively concise introduction to the gas phase at a level suitable for any undergraduate scientist. After defining the gas phase, properties of gases such as temperature, pressure, and volume are discussed. The relationships between these properties are explained at a molecular level, and simple models are introduced that allow the various gas laws to be derived from first principles. Finally, the collisional behaviour of gases is used to explain a number of gas-phase phenomena, such as effusion, diffusion, and thermal conductivity.

  6. Importance of the gas phase role to the prediction of energetic material behavior: An experimental study

    NASA Astrophysics Data System (ADS)

    Ali, A. N.; Son, S. F.; Asay, B. W.; Sander, R. K.

    2005-03-01

    Various thermal (radiative, conductive, and convective) initiation experiments are performed to demonstrate the importance of the gas phase role in combustion modeling of energetic materials (EM). A previously published condensed phase model that includes a predicted critical irradiance above which ignition is not possible is compared to experimental laser ignition results for octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and 2,4,6-trinitrotoluene (TNT). Experimental results conflict with the predicted critical irradiance concept. The failure of the model is believed to result from a misconception about the role of the gas phase in the ignition process of energetic materials. The model assumes that ignition occurs at the surface and that evolution of gases inhibits ignition. High speed video of laser ignition, oven cook-off and hot wire ignition experiments captures the ignition of HMX and TNT in the gas phase. A laser ignition gap test is performed to further evaluate the effect of gas phase laser absorption and gas phase disruption on the ignition process. Results indicate that gas phase absorption of the laser energy is probably not the primary factor governing the gas phase ignition observations. It is discovered that a critical gap between an HMX pellet and a salt window of 6mm±0.4mm exists below which ignition by CO2 laser is not possible at the tested irradiances of 29W /cm2 and 38W/cm2 for HMX ignition. These observations demonstrate that a significant disruption of the gas phase, in certain scenarios, will inhibit ignition, independent of any condensed phase processes. These results underscore the importance of gas phase processes and illustrate that conditions can exist where simple condensed phase models are inadequate to accurately predict the behavior of energetic materials.

  7. The dynamics of surface-catalyzed reactions studied by infrared chemiluminescence of the CO and CO{sub 2} products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watanabe, K.; Uetsuka, H.; Ohnuma, H.

    The infrared chemiluminescence technique has been applied to the selective formation of syngas (CO + H{sub 2}) from the oxidation of small alkanes on Pt, the decomposition and oxidation of CH{sub 3}OH and HCOOH on Pt and Ni, and CO oxidation on Pd(111) and Pd(110). The different internal (vibrational and rotational) energy states of the CO and CO{sub 2} products have been observed, which reflect the difference in the dynamics of these reactions.

  8. Metal-enhanced chemiluminescence from chromium, copper, nickel, and zinc nanodeposits: Evidence for a second enhancement mechanism in metal-enhanced fluorescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weisenberg, Micah; Zhang Yongxia; Geddes, Chris D.

    Over the past decade metal-fluorophore interactions, metal-enhanced fluorescence, have attracted significant research attention, with the technology now becoming common place in life science applications. In this paper, we address the underlying mechanisms of metal-enhanced fluorescence (MEF) and experimentally show using chemiluminescence solutions that MEF is indeed underpinned by two complimentary mechanisms, consistent with the recent reports by Geddes and co-workers [Zhang et al., J. Phys. Chem. C 113, 12095 (2009)] and their enhanced fluorescence hypothesis.

  9. A Small Molecule that Mimics the BB-Loop in the Toll/IL-1 Receptor Domain of MyD88 Attenuates Staphylococcal Enterotoxin B Induced Pro-Inflammatory Cytokine Production and Toxicity in Mice

    DTIC Science & Technology

    2011-06-01

    121.8, 114.6, 67.0, 55.1, 46.6, 45.7, 31.3, 25.9, 24.0, 19.4, 17.6; HRMS: (ESI-TOF) C17H24N2O3H+ expected: 305.1860. found: 305.1860. (S)-1- benzyl -3...chemiluminescent substrate in the presence of hydrogen peroxide using Immun-Star WesternC Chemiluminescent Kit (BioRad). An imaging system VersaDoc Model

  10. Integrated luminometer for the determination of trace metals in seawater using fluorescence, phosphorescence and chemiluminescence detection

    PubMed Central

    Achterberg, E. P.; Bowie, A. R.; Cannizzaro, V.; Charles, S.; Costa, J. M.; Dubois, F.; Pereiro, R.; San Vicente, B.; Sanz-Medel, A.; Vandeloise, R.; Donckt, E. Vander; Wollast, P.; Yunus, S.

    2002-01-01

    The paper describes an integrated luminometer able to perform fluorescence (FL), room temperature phosphorescence (RTP) and chemiluminescence (CL) measurements on seawater samples. The technical details of the instrumentation are presented together with flow injection (FI) manifolds for the determination of cadmium and zinc (by FL), lead (RTP) and cobalt (CL). The analytical figures of merit are given for each manifold and results are presented for the determination of the four trace metals in seawater reference materials (NASS-5, SLEW-2) and Scheldt estuarine water samples. PMID:18924742

  11. Evaluation of the Boson Chemiluminescence Immunoassay as a First-Line Screening Test in the ECDC Algorithm for Syphilis Serodiagnosis in a Population with a High Prevalence of Syphilis

    PubMed Central

    Qiu, Xin-Hui; Zhang, Ya-Feng; Chen, Yu-Yan; Zhang, Qiao; Chen, Fu-Yi; Liu, Long; Fan, Jin-Yi; Gao, Kun; Zhu, Xiao-Zhen; Zheng, Wei-Hong; Zhang, Hui-Lin; Lin, Li-Rong; Liu, Li-Li; Tong, Man-Li; Zhang, Chang-Gong

    2015-01-01

    We developed a new Boson chemiluminescence immunoassay (CIA) and evaluated its application with cross-sectional analyses. Our results indicated that the Boson CIA demonstrated strong discriminatory power in diagnosing syphilis and that it can be used as a first-line screening test for syphilis serodiagnosis using the European Centre for Disease Prevention and Control algorithm or as a confirmatory test when combined with a patient's clinical history. PMID:25631792

  12. Chemiluminescent reaction of oxygen atoms with some nitrile compounds

    NASA Astrophysics Data System (ADS)

    Upadhyaya, Hari P.; Pavanaja, Ubaradka B.; Sapre, Avinash V.; Rama Rao, Kuchimanchi V. S.; Mittal, Jai P.

    1994-09-01

    In a discharge-flow experiment, chemiluminescent reactions of oxygen atoms (O( 3P)) with organic nitriles (RCN) are studied. For unsaturated nitriles RCN (R: CH 2=CH; CH 2=C(CH 3); CH 2=CH(CH 2)) the observed emission is attributed to CN * (B→X) and NO * (γ:A→X and β: B→X, bands). For saturated and phenyl nitriles (R: CH 3; C 2H 5; C 6H 5) emission is only observed from CN * (B 2Σ +). A suitable reaction mechanism for the observed emission is proposed.

  13. Method for detecting pollutants. [through chemical reactions and heat treatment

    NASA Technical Reports Server (NTRS)

    Rogowski, R. S.; Richards, R. R.; Conway, E. J. (Inventor)

    1976-01-01

    A method is described for detecting and measuring trace amounts of pollutants of the group consisting of ozone, nitrogen dioxide, and carbon monoxide in a gaseous environment. A sample organic solid material that will undergo a chemical reaction with the test pollutant is exposed to the test environment and thereafter, when heated in the temperature range of 100-200 C., undergoes chemiluminescence that is measured and recorded as a function of concentration of the test pollutant. The chemiluminescence of the solid organic material is specific to the pollutant being tested.

  14. Flow-injection system for automated dissolution testing of isoniazid tablets with chemiluminescence detection.

    PubMed

    Li, B; Zhang, Z; Liu, W

    2001-05-30

    A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO(4)-isoniazid was also investigated. The sampling frequency of the system was 120 h(-1). The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measuring range and robustness of the system.

  15. Excited state reaction dynamics of Ti(a{sup 5}F{sub J}) + O{sub 2} → TiO(A{sup 3}Φ, B{sup 3}Π, C{sup 3}Δ) + O studied by a crossed-beam velocity map imaging technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Honma, Kenji, E-mail: honm@sci.u-hyogo.ac.jp; Tanaka, Yuhki

    Oxidation reactions of the gas-phase titanium atom in its excited state with oxygen molecule, Ti(a{sup 5}F{sub J}) + O{sub 2} → TiO(A{sup 3}Φ, B{sup 3}Π, C{sup 3}Δ) + O, were studied by a crossed-beam velocity map imaging technique at 14.3 kJ/mol of collision energy. Metastable excited Ti, Ti(a{sup 5}F{sub J}), was generated by an optical pumping method and the reaction products were detected by single photon-ionization followed by a time-of-flight mass analysis and a two dimensional detection. Three wavelengths were selected to ionize electronically excited TiO{sup ∗}, TiO(A{sup 3}Φ, B{sup 3}Π, C{sup 3}Δ). Time sliced images were measured, and angularmore » and speed distributions of TiO{sup ∗} were determined. In all three ionization wavelengths, the angular distributions showed a forward-backward symmetry with low intensity at the sideway direction. The speed distributions were represented by the distributions based on the statistical energy partition into products. These results suggested that the reaction of Ti(a{sup 5}F{sub J}) to form TiO(B) and TiO(C) proceeds via a long-lived intermediate and confirmed that the mechanism proposed by the previous chemiluminescence study.« less

  16. Diaromatic sulphur-containing 'naphthenic' acids in process waters.

    PubMed

    West, Charles E; Scarlett, Alan G; Tonkin, Andrew; O'Carroll-Fitzpatrick, Devon; Pureveen, Jos; Tegelaar, Erik; Gieleciak, Rafal; Hager, Darcy; Petersen, Karina; Tollefsen, Knut-Erik; Rowland, Steven J

    2014-03-15

    Polar organic compounds found in industrial process waters, particularly those originating from biodegraded petroleum residues, include 'naphthenic acids' (NA). Some NA have been shown to have acute toxicity to fish and also to produce sub-lethal effects. Whilst some of these toxic effects are produced by identifiable carboxylic acids, acids such as sulphur-containing acids, which have been detected, but not yet identified, may produce others. Therefore, in the present study, the sulphur-containing acids in oil sands process water were studied. A fraction (ca 12% by weight of the total NA containing ca 1.5% weight sulphur) was obtained by elution of methylated NA through an argentation solid phase extraction column with diethyl ether. This was examined by multidimensional comprehensive gas chromatography-mass spectrometry (GCxGC-MS) in both nominal and high resolution mass accuracy modes and by GCxGC-sulphur chemiluminescence detection (GCxGC-SCD). Interpretation of the mass spectra and retention behaviour of methyl esters of several synthesised sulphur acids and the unknowns allowed delimitation of the structures, but not complete identification. Diaromatic sulphur-containing alkanoic acids were suggested. Computer modelling of the toxicities of some of the possible acids suggested they would have similar toxicities to one another and to dehydroabietic acid. However, the sulphur-rich fraction was not toxic or estrogenic to trout hepatocytes, suggesting the concentrations of sulphur acids in this sample were too low to produce any such effects in vitro. Further samples should probably be examined for these compounds. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Acute consumption of flavanol-rich cocoa and the reversal of endothelial dysfunction in smokers.

    PubMed

    Heiss, Christian; Kleinbongard, Petra; Dejam, Andrè; Perré, Sandra; Schroeter, Hagen; Sies, Helmut; Kelm, Malte

    2005-10-04

    This study was designed to assess the effect of flavanol-rich food on the circulating pool of bioactive nitric oxide (NO) and endothelial dysfunction in smokers. Studies suggest that smoking-related vascular disease is caused by impaired NO synthesis and that diets rich in flavanols can increase bioactive NO in plasma. In smokers (n = 11), the effects of flavanol-rich cocoa on circulating NO species in plasma (RXNO) measured by reductive gas-phase chemiluminescence and endothelial function as assessed by flow-mediated dilation (FMD) were characterized in a dose-finding study orally administering cocoa containing 88 to 370 mg flavanols and in a randomized double-blind crossover study using 100 ml cocoa drink with high (176 to 185 mg) or low (<11 mg) flavanol content on two separate days. In addition to cocoa drink, ascorbic acid and NO-synthase inhibitor L-NMMA (n = 4) were applied. There were significant increases in RXNO (21 +/- 3 nmol/l to 29 +/- 5 nmol/l) and FMD (4.5 +/- 0.8% to 6.9 +/- 0.9%, each p < 0.05) at 2 h after ingestion of 176 to 185 mg flavanols, a dose potentially exerting maximal effects. These changes correlated with increases in flavanol metabolites. Cocoa-associated increases in RXNO and FMD were reversed by L-NMMA. Ascorbic acid had no effect. The circulating pool of bioactive NO and endothelium-dependent vasodilation is acutely increased in smokers following the oral ingestion of a flavanol-rich cocoa drink. The increase in circulating NO pool may contribute to beneficial vascular health effects of flavanol-rich food.

  18. Gas-phase and solution-phase polymerization of epoxides by Cr(salen) complexes: evidence for a dinuclear cationic mechanism.

    PubMed

    Schön, Eva; Zhang, Xiangyang; Zhou, Zhiping; Chisholm, Malcolm H; Chen, Peter

    2004-11-15

    The gas-phase reactions of a series of mass-selected mononuclear and dinuclear Cr(salen) complexes with propylene oxide suggest that the enhanced reactivity of the dinuclear complexes in gas-phase and in solution may derive from a dicationic mechanism in which the alkoxide chain is mu(2)-coordinated to two Lewis acidic metal centers. The double coordination is proposed to suppress backbiting, and hence chain-transfer in the gas-phase homopolymerization of epoxides.

  19. Spontaneous Growth and Mobilization of a Gas Phase in the Presence of Dense Non- Aqueous Phase Liquid (DNAPL)

    NASA Astrophysics Data System (ADS)

    Roy, J. W.; Smith, J. E.

    2006-12-01

    A number of mechanisms can lead to the presence of disconnected bubbles or ganglia of gas phase in groundwater. When associated with or near a DNAPL phase, the disconnected gas phase experiences mass transfer of dissolved gases including the volatile components of the DNAPL. The properties of the gas phase interface, such as interfacial tension and contact angle, can also be affected. This work addresses the behavior of spontaneous continual growth of initially trapped seed gas bubbles within DNAPL source zones. Three different experiments were performed in a 2-dimensional transparent flow cell 15 cm by 20 cm by 1.5 cm. In each case, a DNAPL pool was created within larger glass beads over smaller glass beads that served as a capillary barrier. The DNAPL consisted of either a 1:2 (v/v) tetrachloroethene (PCE) to benzene mixture, single component PCE, or single component TCE. The experiments effectively demonstrate spontaneous gas phase expansion and vertical advective mobilization of gas bubbles and ganglia above the DNAPL source zone. A cycle of gas phase growth and mobilization was facilitated by the presence of secondary seed bubbles left behind due to snap-off during vertical bubble (ganglion) mobilization. This gas phase growth process was relatively slow but continuous and could be expected to continue until the NAPL is completely dissolved. Some implications of the demonstrated behavior for water flow and mass transfer within and near the DNAPL source zone are highlighted.

  20. Energy Distribution among Reaction Products. III: The Method of Measured Relaxation Applied to H + Cl2

    NASA Technical Reports Server (NTRS)

    Pacey, P. D.; Polyani, J. C.

    1971-01-01

    The method of measured relaxation is described for the determination of initial vibrational energy distribution in the products of exothermic reaction. Hydrogen atoms coming from an orifice were diffused into flowing chlorine gas. Measurements were made of the resultant ir chemiluminescence at successive points along the line of flow. The concurrent processes of reaction, diffusion, flow, radiation, and deactivation were analyzed in some detail on a computer. A variety of relaxation models were used in an attempt to place limits on k(nu prime), the rate constant for reaction to form HCl in specified vibrational energy levels: H+Cl2 yields (sup K(nu prime) HCl(sub nu prime) + Cl. The set of k(?) obtained from this work is in satisfactory agreement with those obtained by another experimental method (the method of arrested relaxation described in Parts IV and V of the present series.

  1. Floating liquid phase in sedimenting colloid-polymer mixtures.

    PubMed

    Schmidt, Matthias; Dijkstra, Marjolein; Hansen, Jean-Pierre

    2004-08-20

    Density functional theory and computer simulation are used to investigate sedimentation equilibria of colloid-polymer mixtures within the Asakura-Oosawa-Vrij model of hard sphere colloids and ideal polymers. When the ratio of buoyant masses of the two species is comparable to the ratio of differences in density of the coexisting bulk (colloid) gas and liquid phases, a stable "floating liquid" phase is found, i.e., a thin layer of liquid sandwiched between upper and lower gas phases. The full phase diagram of the mixture under gravity shows coexistence of this floating liquid phase with a single gas phase or a phase involving liquid-gas equilibrium; the phase coexistence lines meet at a triple point. This scenario remains valid for general asymmetric binary mixtures undergoing bulk phase separation.

  2. Enzymatic activity of albumin shown by coelenterazine chemiluminescence.

    PubMed

    Vassel, N; Cox, C D; Naseem, R; Morse, V; Evans, R T; Power, R L; Brancale, A; Wann, K T; Campbell, A K

    2012-01-01

    Bioluminescence, the emission of light from live organisms, occurs in 18 phyla and is the major communication system in the deep sea. It has appeared independently many times during evolution but its origins remain unknown. Coelenterazine bioluminescence discovered in luminous jellyfish is the most common chemistry causing bioluminescence in the sea, occurring in seven phyla. Sequence similarities between coelenterazine luciferases and photoproteins from different phyla are poor (often < 5%). The aim of this study was to examine albumin that binds organic substances as a coelenterazine luciferase to test the hypothesis that the evolutionary origin of a bioluminescent protein was the result of the formation of a solvent cage containing just a few key amino acids. The results show for the first time that bovine and human albumin catalysed coelenterazine chemiluminescence consistent with a mono-oxygenase, whereas gelatin and haemoglobin, an oxygen carrier, had very weak activity. Insulin also catalysed coelenterazine chemiluminescence and was increased by Zn(2+). Albumin chemiluminescence was heat denaturable, exhibited saturable substrate characteristics and was inhibited by cations that bound these proteins and by drugs that bind to human albumin drug site I. Molecular modelling confirmed the coelenterazine binding site and identified four basic amino acids: lys195, arg222, his242 and arg257, potentially important in binding and catalysis similar to naturally occurring coelenterazine bioluminescent proteins. These results support the 'solvent cage' hypothesis for the evolutionary origin of enzymatic coelenterazine bioluminescent proteins. They also have important consequences in diseases such as diabetes, gut disorders and food intolerance where a mono-oxygenase could affect cell surface proteins. Copyright © 2012 John Wiley & Sons, Ltd.

  3. An enhanced chemiluminescence resonance energy transfer aptasensor based on rolling circle amplification and WS2 nanosheet for Staphylococcus aureus detection.

    PubMed

    Hao, Liling; Gu, Huajie; Duan, Nuo; Wu, Shijia; Ma, Xiaoyuan; Xia, Yu; Tao, Zui; Wang, Zhouping

    2017-03-22

    A chemiluminescence resonance energy transfer aptasensor was fabricated for the detection of Staphylococcus aureus (S. aureus) with Co 2+ enhanced N-(aminobutyl)-N-(ethylisoluminol) (ABEI) functional flowerlike gold nanoparticles (Co 2+ /ABEI-AuNFs) as donor and WS 2 nanosheet as acceptor. In the presence of S. aureus, rolling circle amplification (RCA) can be started. Partially complementary sequence of RCA product functional ABEI-AuNFs (cDNA-ABEI-AuNFs) were then annealed to multiple sites of the RCA product to form duplex complex. This complex is less adsorbed onto the WS 2 nanosheet, thus attenuating the quenching of ABEI-AuNFs chemiluminescence by WS 2 nanosheet. In the absence of target S. aureus (and hence the absence of RCA and duplex formation), the free cDNA-ABEI-AuNFs is completely adsorbed onto the WS 2 nanosheet and chemiluminescence quenching ensues. Under optimal conditions, the logarithmic correlation between the concentration of S. aureus and the CL signal was found to be linear within the range of 50 cfu/mL to 1.5 × 10 5  cfu/mL (R 2  = 0.9913). The limits of detection of the developed method were found to be 15 cfu/mL for S. aureus. The selectivity and the capability of the biosensor in meat samples were also studied. Therefore, this simple and easy operation method can be used to detect S. aureus with high sensitivity and specificity. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Measurement of proteases using chemiluminescence-resonance-energy-transfer chimaeras between green fluorescent protein and aequorin.

    PubMed Central

    Waud, J P; Bermúdez Fajardo, A; Sudhaharan, T; Trimby, A R; Jeffery, J; Jones, A; Campbell, A K

    2001-01-01

    Homogeneous assays, without a separation step, are essential for measuring chemical events in live cells and for drug discovery screens, and are desirable for making measurements in cell extracts or clinical samples. Here we demonstrate the principle of chemiluminescence resonance energy transfer (CRET) as a homogeneous assay system, using two proteases as models, one extracellular (alpha-thrombin) and the other intracellular (caspase-3). Chimaeras were engineered with aequorin as the chemiluminescent energy donor and green fluorescent protein (GFP) or enhanced GFP as the energy acceptors, with a protease linker (6 or 18 amino acid residues) recognition site between the donor and acceptor. Flash chemiluminescent spectra (20--60 s) showed that the spectra of chimaeras matched GFP, being similar to that of luminous jellyfish, justifying their designation as 'Rainbow' proteins. Addition of the protease shifted the emission spectrum to that of aequorin in a time- and dose-dependent manner. Separation of the proteolysed fragments showed that the ratio of green to blue light matched the extent of proteolysis. The caspase-3 Rainbow protein was able to provide information on the specificity of caspases in vitro and in vivo. It was also able to monitor caspase-3 activation in cells provoked into apoptosis by staurosporine (1 or 2 microM). CRET can also monitor GFP fluor formation. The signal-to-noise ratio of our Rainbow proteins is superior to that of fluorescence resonance energy transfer, providing a potential platform for measuring agents that interact with the reactive site between the donor and acceptor. PMID:11463339

  5. Characterization of a catalyst-based conversion technique to measure total particulate nitrogen and organic carbon and comparison to a particle mass measurement instrument

    NASA Astrophysics Data System (ADS)

    Stockwell, Chelsea E.; Kupc, Agnieszka; Witkowski, Bartłomiej; Talukdar, Ranajit K.; Liu, Yong; Selimovic, Vanessa; Zarzana, Kyle J.; Sekimoto, Kanako; Warneke, Carsten; Washenfelder, Rebecca A.; Yokelson, Robert J.; Middlebrook, Ann M.; Roberts, James M.

    2018-05-01

    The chemical composition of aerosol particles is a key aspect in determining their impact on the environment. For example, nitrogen-containing particles impact atmospheric chemistry, air quality, and ecological N deposition. Instruments that measure total reactive nitrogen (Nr = all nitrogen compounds except for N2 and N2O) focus on gas-phase nitrogen and very few studies directly discuss the instrument capacity to measure the mass of Nr-containing particles. Here, we investigate the mass quantification of particle-bound nitrogen using a custom Nr system that involves total conversion to nitric oxide (NO) across platinum and molybdenum catalysts followed by NO-O3 chemiluminescence detection. We evaluate the particle conversion of the Nr instrument by comparing to mass-derived concentrations of size-selected and counted ammonium sulfate ((NH4)2SO4), ammonium nitrate (NH4NO3), ammonium chloride (NH4Cl), sodium nitrate (NaNO3), and ammonium oxalate ((NH4)2C2O4) particles determined using instruments that measure particle number and size. These measurements demonstrate Nr-particle conversion across the Nr catalysts that is independent of particle size with 98 ± 10 % efficiency for 100-600 nm particle diameters. We also show efficient conversion of particle-phase organic carbon species to CO2 across the instrument's platinum catalyst followed by a nondispersive infrared (NDIR) CO2 detector. However, the application of this method to the atmosphere presents a challenge due to the small signal above background at high ambient levels of common gas-phase carbon compounds (e.g., CO2). We show the Nr system is an accurate particle mass measurement method and demonstrate its ability to calibrate particle mass measurement instrumentation using single-component, laboratory-generated, Nr-containing particles below 2.5 µm in size. In addition we show agreement with mass measurements of an independently calibrated online particle-into-liquid sampler directly coupled to the electrospray ionization source of a quadrupole mass spectrometer (PILS-ESI/MS) sampling in the negative-ion mode. We obtain excellent correlations (R2 = 0.99) of particle mass measured as Nr with PILS-ESI/MS measurements converted to the corresponding particle anion mass (e.g., nitrate, sulfate, and chloride). The Nr and PILS-ESI/MS are shown to agree to within ˜ 6 % for particle mass loadings of up to 120 µg m-3. Consideration of all the sources of error in the PILS-ESI/MS technique yields an overall uncertainty of ±20 % for these single-component particle streams. These results demonstrate the Nr system is a reliable direct particle mass measurement technique that differs from other particle instrument calibration techniques that rely on knowledge of particle size, shape, density, and refractive index.

  6. Microminiature gas chromatograph

    DOEpatents

    Yu, Conrad M.

    1996-01-01

    A microminiature gas chromatograph (.mu.GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode.

  7. A study of interferences in ozone UV and chemiluminescence monitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hudgens, E.E.; Kleindienst, T.E.; McElroy, F.F.

    A study was conducted to examine interferences and other measurement anomalies in chemiluminescence and ultraviolet ozone monitors. Previous results had show that there was a positive deviation in the chemiluminescence monitors and no direct interference with ultraviolet monitors due to the presence of water at non-condensing concentrations. The present study continues this effort, examining both potential positive and negative effects of moisture and other interferences on these monitors. Aromatic compounds and their oxidation products could potentially show a positive interference with ultraviolet monitors, and test measurements were made with aromatics such as toluene, benzaldehyde, and nitrotoluene to determine their possiblemore » retention in the ozone scrubber and their absorption in the cell as a function of the humidity. A detailed examination of the scrubbers used in ultraviolet ozone monitors has also been undertaken. Ozone scrubbers that have shown anomalous behavior in the field have been studied in various reduced-efficacy modes under controlled laboratory conditions. Longer term tests of unused scrubbers for possible ozone breakthrough under exposure to various simulated field conditions were initiated.« less

  8. Camera calibration for multidirectional flame chemiluminescence tomography

    NASA Astrophysics Data System (ADS)

    Wang, Jia; Zhang, Weiguang; Zhang, Yuhong; Yu, Xun

    2017-04-01

    Flame chemiluminescence tomography (FCT), which combines computerized tomography theory and multidirectional chemiluminescence emission measurements, can realize instantaneous three-dimensional (3-D) diagnostics for flames with high spatial and temporal resolutions. One critical step of FCT is to record the projections by multiple cameras from different view angles. For high accuracy reconstructions, it requires that extrinsic parameters (the positions and orientations) and intrinsic parameters (especially the image distances) of cameras be accurately calibrated first. Taking the focus effect of the camera into account, a modified camera calibration method was presented for FCT, and a 3-D calibration pattern was designed to solve the parameters. The precision of the method was evaluated by reprojections of feature points to cameras with the calibration results. The maximum root mean square error of the feature points' position is 1.42 pixels and 0.0064 mm for the image distance. An FCT system with 12 cameras was calibrated by the proposed method and the 3-D CH* intensity of a propane flame was measured. The results showed that the FCT system provides reasonable reconstruction accuracy using the camera's calibration results.

  9. Large enhancement of oscillating chemiluminescence with [Ru(bpy)3 ](2+) -catalyzed Belousov-Zhabotinsky reaction in the presence of tri-n-propylamine.

    PubMed

    Lan, Xiaolan; Zheng, Baozhan; Zhao, Yan; Yuan, Hongyan; Du, Juan; Xiao, Dan

    2013-01-01

    Oscillating chemiluminescence enhanced by the addition of tri-n-propylamine (TPrA) to the typical Belousov-Zhabotinsky (BZ) reaction system catalyzed by ruthenium(II)tris(2.2'-bipyridine)(Ru(bpy)3 (2+) ) was investigated using a luminometry method. The [Ru(bpy)3 ](2+) /TPrA system was first used as the catalyst for a BZ oscillator in a closed system, which exhibited a shorter induction period, higher amplitude and much more stable chemiluminescence (CL) oscillation. The effects of various concentrations of TPrA, oxygen and nitrogen flow rate on the oscillating behavior of this system were examined. In addition, the CL intensity of the [Ru(bpy)3 ](2+) /TPrA-BZ system was found to be inhibited by phenol, thus providing a way for use of the BZ system in the determination of phenolic compounds. Moreover, the possible mechanism of the oscillating CL reaction catalyzed by [Ru(bpy)3 ](2+) /TPrA and the inhibition effects of oxygen and phenol on this oscillating CL system were considered. Copyright © 2012 John Wiley & Sons, Ltd.

  10. A sensitive and selective chemiluminescence sensor for the determination of dopamine based on silanized magnetic graphene oxide-molecularly imprinted polymer.

    PubMed

    Duan, Huimin; Li, Leilei; Wang, Xiaojiao; Wang, Yanhui; Li, Jianbo; Luo, Chuannan

    2015-03-15

    Based on silanized magnetic graphene oxide-molecularly imprinted polymer (Si-MG-MIP), a sensitive and selective chemiluminescence sensor for dopamine measurement was developed. Si-MG-MIP, in which silanes was introduced to improve the mass transfer, graphene oxide was employed to improve absorption capacity, Fe3O4 nanoparticles were applied for separation easily and molecularly imprinted polymer was used to improve selectivity, demonstrated the advantages of the sensor. All the composites were confirmed by SEM, TEM, XRD and FTIR. Under the optimal conditions of chemiluminescence, dopamine could be assayed in the range of 8.0-200.0 ng/mL with a correlation coefficient of linear regression of 0.9970. The detection limit was 1.5 ng/mL (3δ) and the precision for 11 replicate detections of 80.0 ng/mL dopamine was 3.4% (RSD). When the sensor was applied in determining dopamine in actual samples, recovery ranged from 94% to 110%, which revealed that the results were satisfactory. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. A sensitive and selective chemiluminescence sensor for the determination of dopamine based on silanized magnetic graphene oxide-molecularly imprinted polymer

    NASA Astrophysics Data System (ADS)

    Duan, Huimin; Li, Leilei; Wang, Xiaojiao; Wang, Yanhui; Li, Jianbo; Luo, Chuannan

    2015-03-01

    Based on silanized magnetic graphene oxide-molecularly imprinted polymer (Si-MG-MIP), a sensitive and selective chemiluminescence sensor for dopamine measurement was developed. Si-MG-MIP, in which silanes was introduced to improve the mass transfer, graphene oxide was employed to improve absorption capacity, Fe3O4 nanoparticles were applied for separation easily and molecularly imprinted polymer was used to improve selectivity, demonstrated the advantages of the sensor. All the composites were confirmed by SEM, TEM, XRD and FTIR. Under the optimal conditions of chemiluminescence, dopamine could be assayed in the range of 8.0-200.0 ng/mL with a correlation coefficient of linear regression of 0.9970. The detection limit was 1.5 ng/mL (3δ) and the precision for 11 replicate detections of 80.0 ng/mL dopamine was 3.4% (RSD). When the sensor was applied in determining dopamine in actual samples, recovery ranged from 94% to 110%, which revealed that the results were satisfactory.

  12. Luminol-Based Chemiluminescent Signals: Clinical and Non-clinical Application and Future Uses

    PubMed Central

    Khan, Parvez; Idrees, Danish; Moxley, Michael A.; Corbett, John A.; Ahmad, Faizan; von Figura, Guido; Sly, William S.; Waheed, Abdul

    2015-01-01

    Chemiluminescence (CL) is an important method for quantification and analysis of various macromolecules. A wide range of CL agents such as luminol, hydrogen peroxide, fluorescein, dioxetanes and derivatives of oxalate, and acridinium dyes are used according to their biological specificity and utility. This review describes the application of luminol chemiluminescence (LCL) in forensic, biomedical, and clinical sciences. LCL is a very useful detection method due to its selectivity, simplicity, low cost, and high sensitivity. LCL has a dynamic range of applications, including quantification and detection of macro and micromolecules such as proteins, carbohydrates, DNA, and RNA. Luminol-based methods are used in environmental monitoring as biosensors, in the pharmaceutical industry for cellular localization and as biological tracers, and in reporter gene-based assays and several other immunoassays. Here, we also provide information about different compounds that may enhance or inhibit the LCL along with the effect of pH and concentration on LCL. This review covers most of the significant information related to the applications of luminol in different fields. PMID:24752935

  13. Luminol-dependent chemiluminescence in antibody-sensitized neutrophils stimulated with protein A-bearing staphylococci.

    PubMed

    Nishihara, S; Seki, K; Ikigai, H; Masuda, S

    1988-01-01

    When mouse polymorphonuclear leukocytes (PMNs) sensitized with rabbit antibody to mouse Ehrlich ascites tumor cells were stimulated by Staphylococcus aureus Cowan I cells, a conspicuous luminol-dependent chemiluminescence was observed in the absence of opsonin. The profile of the chemiluminescence (CL) response evoked by staphylococcal cells from antibody-sensitized PMNs had two peaks. An initial peak, observed within 1 min after stimulation, was sharp and high and a second peak, observed about 5 min after stimulation, was low and extended. The CL response of antibody-sensitized PMNs stimulated by S. aureus Cowan I cells was dose-dependently blocked by preincubation with soluble SpA. Cells of a mutant derived from S. aureus Cowan I strain with trace amounts of cell-bound SpA failed to stimulate the antibody-sensitized PMNs to generate the CL response. The antibody-sensitized PMNs were found to phagocytize SpA-bearing S. aureus cells even in the absence of opsonic serum. These results suggest that the observation presented here might provide a useful tool for the investigation of CL response of PMNs.

  14. Flow injection chemiluminescence determination of lercanidipine based on N-chlorosuccinimide-eosin Y post-chemiluminescence reaction.

    PubMed

    Wang, Guowei; Zhao, Fang; Gao, Ying

    2014-12-01

    A novel post-chemiluminescence (PCL) reaction was discovered when lercanidipine was injected into the CL reaction mixture of N-chlorosuccinimide with alkaline eosin Y in the presence of cetyltrimethylammonium bromide (CTAB), where eosin Y was used as the CL reagent and CTAB as the surfactant. Based on this observation, a simple and highly sensitive PCL method combined with a flow injection (FI) technique was developed for the assay of lercanidipine. Under optimum conditions, the CL signal was linearly related to the concentration of lercanidipine in the range 7.0 × 10(-10) to 3.0 × 10(-6)  g/mL with a detection limit of 2.3 × 10(-10) g/mL (3σ). The relative standard deviation (RSD) was 2.1% for 1.0 × 10(-8) g/mL lercanidipine (n = 13). The proposed method had been applied to the estimation of lercanidipine in tablets and human serum samples with satisfactory results. The possible CL mechanism is also discussed briefly. Copyright © 2014 John Wiley & Sons, Ltd.

  15. [Effect of smoking on neutrophil oxidative metabolism].

    PubMed

    Zasimauskas, Darius; Zekonis, Gediminas

    2008-01-01

    Alterations in neutrophil function by tobacco products may play a central role in the pathogenesis of periodontal diseases and several smoking-related systemic diseases. The aim of the study was to evaluate the effect of smoking on neutrophil oxidative metabolism. The study included 17 smoking men free of systemic diseases who were referred for treatment of various odontological diseases to outpatient department of Kaunas University of Medicine Hospital. The age of subjects varied from 22 to 43 years. All subjects answered the questions about smoking habits. Clinical examination included assessment of oral hygiene status according to the OHI-s index and periodontal status according to Russell and Ramfjord indices. To evaluate the oxidative metabolism of neutrophils, luminol- and liucigenin-dependent chemiluminescence and nitroblue tetrazolium test were used. After smoking, extracellular liucigenin-dependent chemiluminescence response was higher as compared to the response before smoking, but total (intra- and extracellular) luminol-dependent chemiluminescence response was the same both before and after smoking. Exposure of neutrophils to smoking caused a significant increase in nitroblue tetrazolium reduction. The release of reactive oxygen species in neutrophils exposed to smoking may alter the pathogenic processes in periodontal diseases.

  16. Menstrual cycle-related changes of functional cerebral asymmetries in fine motor coordination.

    PubMed

    Bayer, Ulrike; Hausmann, Markus

    2012-06-01

    Fluctuating sex hormone levels during the menstrual cycle have been shown to affect functional cerebral asymmetries in cognitive domains. These effects seem to result from the neuromodulatory properties of sex hormones and their metabolites on interhemispheric processing. The present study was carried out to investigate whether functional cerebral asymmetries in fine motor coordination as reflected by manual asymmetries are also susceptible to natural sex hormonal variations during the menstrual cycle. Sixteen right-handed women with a regular menstrual cycle performed a finger tapping paradigm consisting of two conditions (simple, sequential) during the low hormone menstrual phase and the high estrogen and progesterone luteal phase. To validate the luteal phase, saliva levels of free progesterone (P) were analysed using chemiluminescence assays. As expected, normally cycling women showed a substantial decrease in manual asymmetries in a more demanding sequential tapping condition involving four fingers compared with simple (repetitive) finger tapping. This reduction in the degree of dominant (right) hand manual asymmetries was evident during the luteal phase. During the menstrual phase, however, manual asymmetries were even reversed in direction, indicating a slight advantage in favour of the non-dominant (left) hand. These findings suggest that functional cerebral asymmetries in fine motor coordination are affected by sex hormonal changes during the menstrual cycle, probably via hormonal modulations of interhemispheric interaction. © 2012 Elsevier Inc. All rights reserved.

  17. Pore-scale interfacial dynamics during gas-supersaturated water injection in porous media - on nucleation, growth and advection of disconnected fluid phases (Invited)

    NASA Astrophysics Data System (ADS)

    Or, D.; Ioannidis, M.

    2010-12-01

    Degassing and in situ development of a mobile gas bubbles occur when injecting supersaturated aqueous phase into water-saturated porous media. Supersaturated water injection (SWI) has potentially significant applications in remediation of soils contaminated by non-aqueous phase liquids and in enhanced oil recovery. Pore network simulations indicate the formation of a region near the injection boundary where gas phase nuclei are activated and grow by mass transfer from the flowing supersaturated aqueous phase. Ramified clusters of gas-filled pores develop which, owing to the low prevailing Bond number, grow laterally to a significant extent prior to the onset of mobilization, and are thus likely to coalesce. Gas cluster mobilization invariably results in fragmentation and stranding, such that a macroscopic region containing few tenuously connected large gas clusters is established. Beyond this region, gas phase nucleation and mass transfer from the aqueous phase are limited by diminishing supply of dissolved gas. New insights into SWI dynamics are obtained using rapid micro-visualization in transparent glass micromodels. Using high-speed imaging, we observe the nucleation, initial growth and subsequent fate (mobilization, fragmentation, collision, coalescence and stranding) of CO2 bubbles and clusters of gas-filled pores and analyze cluster population statistics. We find significant support for the development of invasion-percolation-like patterns, but also report on hitherto unaccounted for gas bubble behavior. Additionally, we report for the first time on the acoustic emission signature of SWI in porous media and relate it to the dynamics of bubble nucleation and growth. Finally, we identify the pore-scale mechanisms associated with the mobilization and subsequent recovery of a residual non-aqueous phase liquid due to gas bubble dynamics during SWI.

  18. System for measuring multiphase flow using multiple pressure differentials

    DOEpatents

    Fincke, James R.

    2003-01-01

    An improved method and system for measuring a multi-phase flow in a pressure flow meter. An extended throat venturi is used and pressure of the multi-phase flow is measured at three or more positions in the venturi, which define two or more pressure differentials in the flow conduit. The differential pressures are then used to calculate the mass flow of the gas phase, the total mass flow, and the liquid phase. The system for determining the mass flow of the high void fraction fluid flow and the gas flow includes taking into account a pressure drop experienced by the gas phase due to work performed by the gas phase in accelerating the liquid phase.

  19. Ionic Liquid Fuels for Chemical Propulsion

    DTIC Science & Technology

    2016-10-31

    nucleophilicity in the ionic liquid is critical. Both gas -phase and condensed-phase (CPCM-GIL) density functional theory calculations support the...stability trends in dialkylimidazolium ionic liquids and could be used as a higher accuracy method than the gas -phase DFT approach for predicting thermal...stabilities of ionic liquids in general. One important finding from the comparison of the gas -phase basicities relative to the GIL condensed- phase

  20. Gas Phase Nanoparticle Synthesis

    NASA Astrophysics Data System (ADS)

    Granqvist, Claes; Kish, Laszlo; Marlow, William

    This book deals with gas-phase nanoparticle synthesis and is intended for researchers and research students in nanomaterials science and engineering, condensed matter physics and chemistry, and aerosol science. Gas-phase nanoparticle synthesis is instrumental to nanotechnology - a field in current focus that raises hopes for environmentally benign, resource-lean manufacturing. Nanoparticles can be produced by many physical, chemical, and even biological routes. Gas-phase synthesis is particularly interesting since one can achieve accurate manufacturing control and hence industrial viability.

  1. Multi-Scale Morphological Analysis of Conductance Signals in Vertical Upward Gas-Liquid Two-Phase Flow

    NASA Astrophysics Data System (ADS)

    Lian, Enyang; Ren, Yingyu; Han, Yunfeng; Liu, Weixin; Jin, Ningde; Zhao, Junying

    2016-11-01

    The multi-scale analysis is an important method for detecting nonlinear systems. In this study, we carry out experiments and measure the fluctuation signals from a rotating electric field conductance sensor with eight electrodes. We first use a recurrence plot to recognise flow patterns in vertical upward gas-liquid two-phase pipe flow from measured signals. Then we apply a multi-scale morphological analysis based on the first-order difference scatter plot to investigate the signals captured from the vertical upward gas-liquid two-phase flow loop test. We find that the invariant scaling exponent extracted from the multi-scale first-order difference scatter plot with the bisector of the second-fourth quadrant as the reference line is sensitive to the inhomogeneous distribution characteristics of the flow structure, and the variation trend of the exponent is helpful to understand the process of breakup and coalescence of the gas phase. In addition, we explore the dynamic mechanism influencing the inhomogeneous distribution of the gas phase in terms of adaptive optimal kernel time-frequency representation. The research indicates that the system energy is a factor influencing the distribution of the gas phase and the multi-scale morphological analysis based on the first-order difference scatter plot is an effective method for indicating the inhomogeneous distribution of the gas phase in gas-liquid two-phase flow.

  2. Comparing the catalytic oxidation of ethanol at the solid-gas and solid-liquid interfaces over size-controlled Pt nanoparticles: striking differences in kinetics and mechanism.

    PubMed

    Sapi, Andras; Liu, Fudong; Cai, Xiaojun; Thompson, Christopher M; Wang, Hailiang; An, Kwangjin; Krier, James M; Somorjai, Gabor A

    2014-11-12

    Pt nanoparticles with controlled size (2, 4, and 6 nm) are synthesized and tested in ethanol oxidation by molecular oxygen at 60 °C to acetaldehyde and carbon dioxide both in the gas and liquid phases. The turnover frequency of the reaction is ∼80 times faster, and the activation energy is ∼5 times higher at the gas-solid interface compared to the liquid-solid interface. The catalytic activity is highly dependent on the size of the Pt nanoparticles; however, the selectivity is not size sensitive. Acetaldehyde is the main product in both media, while twice as much carbon dioxide was observed in the gas phase compared to the liquid phase. Added water boosts the reaction in the liquid phase; however, it acts as an inhibitor in the gas phase. The more water vapor was added, the more carbon dioxide was formed in the gas phase, while the selectivity was not affected by the concentration of the water in the liquid phase. The differences in the reaction kinetics of the solid-gas and solid-liquid interfaces can be attributed to the molecular orientation deviation of the ethanol molecules on the Pt surface in the gas and liquid phases as evidenced by sum frequency generation vibrational spectroscopy.

  3. Flow-pattern identification and nonlinear dynamics of gas-liquid two-phase flow in complex networks.

    PubMed

    Gao, Zhongke; Jin, Ningde

    2009-06-01

    The identification of flow pattern is a basic and important issue in multiphase systems. Because of the complexity of phase interaction in gas-liquid two-phase flow, it is difficult to discern its flow pattern objectively. In this paper, we make a systematic study on the vertical upward gas-liquid two-phase flow using complex network. Three unique network construction methods are proposed to build three types of networks, i.e., flow pattern complex network (FPCN), fluid dynamic complex network (FDCN), and fluid structure complex network (FSCN). Through detecting the community structure of FPCN by the community-detection algorithm based on K -mean clustering, useful and interesting results are found which can be used for identifying five vertical upward gas-liquid two-phase flow patterns. To investigate the dynamic characteristics of gas-liquid two-phase flow, we construct 50 FDCNs under different flow conditions, and find that the power-law exponent and the network information entropy, which are sensitive to the flow pattern transition, can both characterize the nonlinear dynamics of gas-liquid two-phase flow. Furthermore, we construct FSCN and demonstrate how network statistic can be used to reveal the fluid structure of gas-liquid two-phase flow. In this paper, from a different perspective, we not only introduce complex network theory to the study of gas-liquid two-phase flow but also indicate that complex network may be a powerful tool for exploring nonlinear time series in practice.

  4. Free Radical Oxidation in Rat Myocardium after Maximum Permissible Hepatic Resection.

    PubMed

    Ermolaev, P A; Khramykh, T P; Barskaya, L O

    2016-03-01

    Free radical oxidation in rat myocardial homogenate was studied by chemiluminescent assay during the early terms after maximum permissible liver resection. During this period, activation of free radical oxidation was biphasic. The critical terms characterized by dramatic intensification of free radical oxidation in the myocardium are the first hour and the first day after surgery. The period from 3 to 12 h after surgery, in which the indices of chemiluminescence decrease, can be tentatively termed as the period of "putative wellbeing". Normalization of the free radical oxidation processes in the myocardium occurred by day 7 after surgery.

  5. Evaluation of the boson chemiluminescence immunoassay as a first-line screening test in the ECDC algorithm for syphilis serodiagnosis in a population with a high prevalence of syphilis.

    PubMed

    Qiu, Xin-Hui; Zhang, Ya-Feng; Chen, Yu-Yan; Zhang, Qiao; Chen, Fu-Yi; Liu, Long; Fan, Jin-Yi; Gao, Kun; Zhu, Xiao-Zhen; Zheng, Wei-Hong; Zhang, Hui-Lin; Lin, Li-Rong; Liu, Li-Li; Tong, Man-Li; Zhang, Chang-Gong; Niu, Jian-Jun; Yang, Tian-Ci

    2015-04-01

    We developed a new Boson chemiluminescence immunoassay (CIA) and evaluated its application with cross-sectional analyses. Our results indicated that the Boson CIA demonstrated strong discriminatory power in diagnosing syphilis and that it can be used as a first-line screening test for syphilis serodiagnosis using the European Centre for Disease Prevention and Control algorithm or as a confirmatory test when combined with a patient's clinical history. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. Sonochemical fabrication of 8-hydroxyquinoline aluminum (Alq3) nanoflowers with high electrogenerated chemiluminescence.

    PubMed

    Mao, Chang-Jie; Wang, Dan-Chen; Pan, Hong-Cheng; Zhu, Jun-Jie

    2011-03-01

    Well-defined Alq(3) nanoflowers were fabricated via a facile and fast sonochemical route. X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), field-emission scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to characterize the structure and shape of the as-prepared product. The results showed that the resulting Alq(3) was composed of nanobelts with thickness about 50 nm, average widths of 200 nm, and length up to 10 μm. The Alq(3) nanoflowers exhibited good electrogenerated chemiluminescence behavior. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Optical Diagnosis of Gas Turbine Combustors Being Conducted

    NASA Technical Reports Server (NTRS)

    Hicks, Yolanda R.; Locke, Randy J.; Anderson, Robert C.; DeGroot, Wilhelmus A.

    2001-01-01

    Researchers at the NASA Glenn Research Center, in collaboration with industry, are reducing gas turbine engine emissions by studying visually the air-fuel interactions and combustion processes in combustors. This is especially critical for next generation engines that, in order to be more fuel-efficient, operate at higher temperatures and pressures than the current fleet engines. Optically based experiments were conducted in support of the Ultra-Efficient Engine Technology program in Glenn's unique, world-class, advanced subsonic combustion rig (ASCR) facility. The ASCR can supply air and jet fuel at the flow rates, temperatures, and pressures that simulate the conditions expected in the combustors of high-performance, civilian aircraft engines. In addition, this facility is large enough to support true sectors ("pie" slices of a full annular combustor). Sectors enable one to test true shapes rather than rectangular approximations of the actual hardware. Therefore, there is no compromise to actual engine geometry. A schematic drawing of the sector test stand is shown. The test hardware is mounted just upstream of the instrumentation section. The test stand can accommodate hardware up to 0.76-m diameter by 1.2-m long; thus sectors or small full annular combustors can be examined in this facility. Planar (two-dimensional) imaging using laser-induced fluorescence and Mie scattering, chemiluminescence, and video imagery were obtained for a variety of engine cycle conditions. The hardware tested was a double annular sector (two adjacent fuel injectors aligned radially) representing approximately 15 of a full annular combustor. An example of the two-dimensional data obtained for this configuration is also shown. The fluorescence data show the location of fuel and hydroxyl radical (OH) along the centerline of the fuel injectors. The chemiluminescence data show C2 within the total observable volume. The top row of this figure shows images obtained at an engine low-power condition, and the bottom row shows data from a higher power operating point. The data show distinctly the differences in flame structure between low-power and high-power engine conditions, in both location and amount of species produced (OH, C2) or consumed (fuel). The unique capability of the facility coupled with its optical accessibility helps to eliminate the need for high-pressure performance extrapolations. Tests such as described here have been used successfully to assess the performance of fuel-injection concepts and to modify those designs, if needed.

  8. Microminiature gas chromatograph

    DOEpatents

    Yu, C.M.

    1996-12-10

    A microminiature gas chromatograph ({mu}GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode. 7 figs.

  9. Numerical study of the direct pressure effect of acoustic waves in planar premixed flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, H.; Jimenez, C.

    Recently the unsteady response of 1-D premixed flames to acoustic pressure waves for the range of frequencies below and above the inverse of the flame transit time was investigated experimentally using OH chemiluminescence Wangher (2008). They compared the frequency dependence of the measured response to the prediction of an analytical model proposed by Clavin et al. (1990), derived from the standard flame model (one-step Arrhenius kinetics) and to a similar model proposed by McIntosh (1991). Discrepancies between the experimental results and the model led to the conclusion that the standard model does not provide an adequate description of the unsteadymore » response of real flames and that it is necessary to investigate more realistic chemical models. Here we follow exactly this suggestion and perform numerical studies of the response of lean methane flames using different reaction mechanisms. We find that the global flame response obtained with both detailed chemistry (GRI3.0) and a reduced multi-step model by Peters (1996) lies slightly above the predictions of the analytical model, but is close to experimental results. We additionally used an irreversible one-step Arrhenius reaction model and show the effect of the pressure dependence of the global reaction rate in the flame response. Our results suggest first that the current models have to be extended to capture the amplitude and phase results of the detailed mechanisms, and second that the correlation between the heat release and the measured OH* chemiluminescence should be studied deeper. (author)« less

  10. High-throughput receptor-based assay for the detection of spirolides by chemiluminescence.

    PubMed

    Rodríguez, Laura P; Vilariño, Natalia; Molgó, Jordi; Aráoz, Rómulo; Botana, Luis M

    2013-12-01

    The spirolides are marine toxins that belong to a new class of macrocyclic imines produced by dinoflagellates. In this study a previously described solid-phase receptor-based assay for the detection of spirolides was optimized for high-throughput screening and prevalidated. This method is based on the competition between 13-desmethyl spirolide C and biotin-α-bungarotoxin immobilized on a streptavidin-coated surface, for binding to nicotinic acetylcholine receptors. In this inhibition assay the amount of nAChR bound to the well surface is quantified using a specific antibody, followed by a second anti-mouse IgG antibody labeled with horseradish peroxidase (HRP). The assay protocol was optimized for 384-well microplates, which allowed a reduction of the amount of reagents per sample and an increase of the number of samples per plate versus previously published receptor-based assays. The sensitivity of the assay for 13-desmethyl spirolide C ranged from 5 to 150 ng mL(-1). The performance of the assay in scallop extracts was adequate, with an estimated detection limit for 13-desmethyl spirolide C of 50 μg kg(-1) of shellfish meat. The recovery rate of 13-desmethyl spirolide C for spiked samples with this assay was 80% and the inter-assay coefficient of variation was 8%. This 384-well microplate, chemiluminescence method can be used as a high-throughput screening assay to detect 13-desmethyl spirolide C in shellfish meat in order to reduce the number of samples to be processed through bioassays or analytical methods. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Automated high performance liquid chromatography with on-line reduction of disulfides and chemiluminescence detection for determination of thiols and disulfides in biological fluids.

    PubMed

    Bai, Shouli; Chen, Qingshuo; Lu, Chao; Lin, Jin-Ming

    2013-03-20

    In general, the reduction of disulfide bonds with tris(2-carboxyethyl)phosphine (TCEP) is performed using off-line operation, which is not only time-consuming but also vulnerable to the spontaneous re-oxidation of thiols during sample preparation and subsequent analysis procedures. To the best of our knowledge, there has been not any case on the on-line reduction for biological disulfides coupled with high performance liquid chromatography (HPLC). In this study, these obstacles are overcome by packing Zn(II)-TCEP complexes into a home-made column. The as-synthesized Zn(II)-TCEP complexes enable efficient reduction of disulfide bonds at pH 3.0. This acidic pH value was compatible with that of the mobile phase for HPLC separation of thiols and disulfides. Therefore, using fluorosurfactant-prepared triangular gold nanoparticles as HPLC postcolumn specific chemiluminescence (CL) reagents for thiols, the feasibility of the established on-line reduction column has been confirmed for the direct identification of both thiols and disulfides by incorporating this reduction column into a single chromatographic separation. Detection limits for these analytes range from 8.3 to 25.4 nM and the linear range in a log-log plot can comprise three orders of magnitude. Finally, the utility of this automated on-line reduction of disulfides-HPLC-CL system has been demonstrated for the reliable determination of thiols and disulfides in human urine and plasma samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Interference-free coherence dynamics of gas-phase molecules using spectral focusing.

    PubMed

    Wrzesinski, Paul J; Roy, Sukesh; Gord, James R

    2012-10-08

    Spectral focusing using broadband femtosecond pulses to achieve highly selective measurements has been employed for numerous applications in spectroscopy and microspectroscopy. In this work we highlight the use of spectral focusing for selective excitation and detection of gas-phase species. Furthermore, we demonstrate that spectral focusing, coupled with time-resolved measurements based upon probe delay, allows the observation of interference-free coherence dynamics of multiple molecules and gas-phase temperature making this technique ideal for gas-phase measurements of reacting flows and combustion processes.

  13. Controlling the growth of multiple ordered heteromolecular phases by utilizing intermolecular repulsion

    NASA Astrophysics Data System (ADS)

    Henneke, Caroline; Felter, Janina; Schwarz, Daniel; Stefan Tautz, F.; Kumpf, Christian

    2017-06-01

    Metal/organic interfaces and their structural, electronic, spintronic and thermodynamic properties have been investigated intensively, aiming to improve and develop future electronic devices. In this context, heteromolecular phases add new design opportunities simply by combining different molecules. However, controlling the desired phases in such complex systems is a challenging task. Here, we report an effective way of steering the growth of a bimolecular system composed of adsorbate species with opposite intermolecular interactions--repulsive and attractive, respectively. The repulsive species forms a two-dimensional lattice gas, the density of which controls which crystalline phases are stable. Critical gas phase densities determine the constant-area phase diagram that describes our experimental observations, including eutectic regions with three coexisting phases. We anticipate the general validity of this type of phase diagram for binary systems containing two-dimensional gas phases, and also show that the density of the gas phase allows engineering of the interface structure.

  14. Gas-phase water-mediated equilibrium between methylglyoxal and its geminal diol

    PubMed Central

    Axson, Jessica L.; Takahashi, Kaito; De Haan, David O.; Vaida, Veronica

    2010-01-01

    In aqueous solution, aldehydes, and to a lesser extent ketones, hydrate to form geminal diols. We investigate the hydration of methylglyoxal (MG) in the gas phase, a process not previously considered to occur in water-restricted environments. In this study, we spectroscopically identified methylglyoxal diol (MGD) and obtained the gas-phase partial pressures of MG and MGD. These results, in conjunction with the relative humidity, were used to obtain the equilibrium constant, KP, for the water-mediated hydration of MG in the gas phase. The Gibbs free energy for this process, ΔG°, obtained as a result, suggests a larger than expected gas-phase diol concentration. This may have significant implications for understanding the role of organics in atmospheric chemistry. PMID:20142510

  15. Combustion chemistry of ethanol: Ignition and speciation studies in a rapid compression facility [On the combustion chemistry of ethanol: Ignition and speciation studies in a rapid compression facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barraza-Botet, Cesar L.; Wagnon, Scott W.; Wooldridge, Margaret S.

    Here, ethanol remains the most important alternative fuel for the transportation sector. This work presents new experimental data on ethanol ignition, including stable species measurements, obtained with the University of Michigan rapid compression facility. Ignition delay times were determined from pressure histories of ignition experiments with stoichiometric ethanol–air mixtures at pressures of ~3–10 atm. Temperatures (880–1150 K) were controlled by varying buffer gas composition (Ar, N 2, CO 2). High-speed imaging was used to record chemiluminescence during the experiments, which showed homogeneous ignition events. The results for ignition delay time agreed well with trends on the basis of previous experimentalmore » measurements. Speciation experiments were performed using fast gas sampling and gas chromatography to identify and quantify ethanol and 11 stable intermediate species formed during the ignition delay period. Simulations were carried out using a chemical kinetic mechanism available in the literature, and the agreement with the experimental results for ignition delay time and the intermediate species measured was excellent for the majority of the conditions studied. From the simulation results, ethanol + HO 2 was identified as an important reaction at the experimental conditions for both the ignition delay time and intermediate species measurements. Further studies to improve the accuracy of the rate coefficient for ethanol + HO 2 would improve the predictive understanding of intermediate and low-temperature ethanol combustion.« less

  16. Combustion chemistry of ethanol: Ignition and speciation studies in a rapid compression facility [On the combustion chemistry of ethanol: Ignition and speciation studies in a rapid compression facility

    DOE PAGES

    Barraza-Botet, Cesar L.; Wagnon, Scott W.; Wooldridge, Margaret S.

    2016-08-31

    Here, ethanol remains the most important alternative fuel for the transportation sector. This work presents new experimental data on ethanol ignition, including stable species measurements, obtained with the University of Michigan rapid compression facility. Ignition delay times were determined from pressure histories of ignition experiments with stoichiometric ethanol–air mixtures at pressures of ~3–10 atm. Temperatures (880–1150 K) were controlled by varying buffer gas composition (Ar, N 2, CO 2). High-speed imaging was used to record chemiluminescence during the experiments, which showed homogeneous ignition events. The results for ignition delay time agreed well with trends on the basis of previous experimentalmore » measurements. Speciation experiments were performed using fast gas sampling and gas chromatography to identify and quantify ethanol and 11 stable intermediate species formed during the ignition delay period. Simulations were carried out using a chemical kinetic mechanism available in the literature, and the agreement with the experimental results for ignition delay time and the intermediate species measured was excellent for the majority of the conditions studied. From the simulation results, ethanol + HO 2 was identified as an important reaction at the experimental conditions for both the ignition delay time and intermediate species measurements. Further studies to improve the accuracy of the rate coefficient for ethanol + HO 2 would improve the predictive understanding of intermediate and low-temperature ethanol combustion.« less

  17. 3D motion picture of transparent gas flow by parallel phase-shifting digital holography

    NASA Astrophysics Data System (ADS)

    Awatsuji, Yasuhiro; Fukuda, Takahito; Wang, Yexin; Xia, Peng; Kakue, Takashi; Nishio, Kenzo; Matoba, Osamu

    2018-03-01

    Parallel phase-shifting digital holography is a technique capable of recording three-dimensional (3D) motion picture of dynamic object, quantitatively. This technique can record single hologram of an object with an image sensor having a phase-shift array device and reconstructs the instantaneous 3D image of the object with a computer. In this technique, a single hologram in which the multiple holograms required for phase-shifting digital holography are multiplexed by using space-division multiplexing technique pixel by pixel. We demonstrate 3D motion picture of dynamic and transparent gas flow recorded and reconstructed by the technique. A compressed air duster was used to generate the gas flow. A motion picture of the hologram of the gas flow was recorded at 180,000 frames/s by parallel phase-shifting digital holography. The phase motion picture of the gas flow was reconstructed from the motion picture of the hologram. The Abel inversion was applied to the phase motion picture and then the 3D motion picture of the gas flow was obtained.

  18. Constant volume gas cell optical phase-shifter

    DOEpatents

    Phillion, Donald W.

    2002-01-01

    A constant volume gas cell optical phase-shifter, particularly applicable for phase-shifting interferometry, contains a sealed volume of atmospheric gas at a pressure somewhat different than atmospheric. An optical window is present at each end of the cell, and as the length of the cell is changed, the optical path length of a laser beam traversing the cell changes. The cell comprises movable coaxial tubes with seals and a volume equalizing opening. Because the cell is constant volume, the pressure, temperature, and density of the contained gas do not change as the cell changes length. This produces an exactly linear relationship between the change in the length of the gas cell and the change in optical phase of the laser beam traversing it. Because the refractive index difference between the gas inside and the atmosphere outside is very much the same, a large motion must be made to change the optical phase by the small fraction of a wavelength that is required by phase-shifting interferometry for its phase step. This motion can be made to great fractional accuracy.

  19. Modeling the Phase Composition of Gas Condensate in Pipelines

    NASA Astrophysics Data System (ADS)

    Dudin, S. M.; Zemenkov, Yu D.; Shabarov, A. B.

    2016-10-01

    Gas condensate fields demonstrate a number of thermodynamic characteristics to be considered when they are developed, as well as when gas condensate is transported and processed. A complicated phase behavior of the gas condensate system, as well as the dependence of the extracted raw materials on the phase state of the deposit other conditions being equal, is a key aspect. Therefore, when designing gas condensate lines the crucial task is to select the most appropriate methods of calculating thermophysical properties and phase equilibrium of the transported gas condensate. The paper describes a physical-mathematical model of a gas-liquid flow in the gas condensate line. It was developed based on balance equations of conservation of mass, impulse and energy of the transported medium within the framework of a quasi-1D approach. Constitutive relationships are given separately, and practical recommendations on how to apply the research results are provided as well.

  20. Comparison of electrical and optical characteristics in gas-phase and gas-liquid phase discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qazi, H. I. A.; Li, He-Ping, E-mail: liheping@tsinghua.edu.cn; Zhang, Xiao-Fei

    This paper presents an AC-excited argon discharge generated using a gas-liquid (two-phase) hybrid plasma reactor, which mainly consists of a powered needle electrode enclosed in a conical quartz tube and grounded deionized water electrode. The discharges in the gas-phase, as well as in the two-phase, exhibit two discharge modes, i.e., the low current glow-like diffuse mode and the high current streamer-like constrict mode, with a mode transition, which exhibits a negative resistance of the discharges. The optical emission spectral analysis shows that the stronger diffusion of the water vapor into the discharge region in the two-phase discharges boosts up themore » generation of OH (A–X) radicals, and consequently, leads to a higher rotational temperature in the water-phase plasma plume than that of the gas-phase discharges. Both the increase of the power input and the decrease of the argon flow rate result in the increase of the rotational temperature in the plasma plume of the water-phase discharge. The stable two-phase discharges with a long plasma plume in the water-phase under a low power input and gas flow rate may show a promising prospect for the degradation of organic pollutants, e.g., printing and dyeing wastewater, in the field of environmental protection.« less

  1. Pressure Dependence of Gas-Phase Reaction Rates

    ERIC Educational Resources Information Center

    De Persis, Stephanie; Dollet, Alain; Teyssandier, Francis

    2004-01-01

    It is presented that only simple concepts, mainly taken from activated-complex or transition-state theory, are required to explain and analytically describe the influence of pressure on gas-phase reaction kinetics. The simplest kind of elementary gas-phase reaction is a unimolecular decomposition reaction.

  2. Mutual influence of molecular diffusion in gas and surface phases

    NASA Astrophysics Data System (ADS)

    Hori, Takuma; Kamino, Takafumi; Yoshimoto, Yuta; Takagi, Shu; Kinefuchi, Ikuya

    2018-01-01

    We develop molecular transport simulation methods that simultaneously deal with gas- and surface-phase diffusions to determine the effect of surface diffusion on the overall diffusion coefficients. The phenomenon of surface diffusion is incorporated into the test particle method and the mean square displacement method, which are typically employed only for gas-phase transport. It is found that for a simple cylindrical pore, the diffusion coefficients in the presence of surface diffusion calculated by these two methods show good agreement. We also confirm that both methods reproduce the analytical solution. Then, the diffusion coefficients for ink-bottle-shaped pores are calculated using the developed method. Our results show that surface diffusion assists molecular transport in the gas phase. Moreover, the surface tortuosity factor, which is known to be uniquely determined by physical structure, is influenced by the presence of gas-phase diffusion. This mutual influence of gas-phase diffusion and surface diffusion indicates that their simultaneous calculation is necessary for an accurate evaluation of the diffusion coefficients.

  3. Modeling of Liquid Steel/Slag/Argon Gas Multiphase Flow During Tundish Open Eye Formation in a Two-Strand Tundish

    NASA Astrophysics Data System (ADS)

    Chatterjee, Saikat; Li, Donghui; Chattopadhyay, Kinnor

    2018-04-01

    Multiphase flows are frequently encountered in metallurgical operations. One of the most effective ways to understand these processes is by flow modeling. The process of tundish open eye (TOE) formation involves three-phase interaction between liquid steel, slag, and argon gas. The two-phase interaction involving argon gas bubbles and liquid steel can be modeled relatively easily using the discrete phase modeling technique. However, the effect of an upper slag layer cannot be captured using this approach. The presence of an upper buoyant phase can have a major effect on the behavior of TOEs. Hence, a multiphase model, including three phases, viz. liquid steel, slag, and argon gas, in a two-strand slab caster tundish, was developed to study the formation and evolution of TOEs. The volume of fluid model was used to track the interphase between liquid steel and slag phases, while the discrete phase model was used to trace the movement of the argon gas bubbles in liquid steel. The variation in the TOE areas with different amounts of aspirated argon gas was examined in the presence of an overlying slag phase. The mathematical model predictions were compared against steel plant measurements.

  4. Comparative study of β-glucan induced respiratory burst measured by nitroblue tetrazolium assay and real-time luminol-enhanced chemiluminescence assay in common carp (Cyprinus carpio L.).

    PubMed

    Vera-Jimenez, N I; Pietretti, D; Wiegertjes, G F; Nielsen, M E

    2013-05-01

    The respiratory burst is an important feature of the immune system. The increase in cellular oxygen uptake that marks the initiation of the respiratory burst is followed by the production of reactive oxygen species (ROS) such as superoxide anion and hydrogen peroxide which plays a role in the clearance of pathogens and tissue regeneration processes. Therefore, the respiratory burst and associated ROS constitute important indicators of fish health status. This paper compares two methods for quantitation of ROS produced during the respiratory burst in common carp: the widely used, single-point measurement based on the intracellular reduction of nitroblue tetrazolium (NBT) and a real-time luminol-enhanced assay based on the detection of native chemiluminescence. Both assays allowed for detection of dose-dependent changes in magnitude of the respiratory burst response induced by β-glucans in head kidney cells of carp. However, whereas the NBT assay was shown to detect the production of only superoxide anions, the real-time luminol-enhanced assay could detect the production of both superoxide anions and hydrogen peroxide. Only the chemiluminescence assay could reliably record the production of ROS on a real-time scale at frequent and continual time intervals for time course experiments, providing more detailed information on the respiratory burst response. The real-time chemiluminescence assay was used to measure respiratory burst activity in macrophage and neutrophilic granulocyte-enriched head kidney cell fractions and total head kidney cell suspensions and proved to be a fast, reliable, automated multiwell microplate assay to quantitate fish health status modulated by β-glucans. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Multiplexed chemiluminescent assays in ArrayPlates for high-throughput measurement of gene expression

    NASA Astrophysics Data System (ADS)

    Martel, Ralph R.; Rounseville, Matthew P.; Botros, Ihab W.; Seligmann, Bruce E.

    2002-06-01

    Multiplexed Molecular Profiling (MMP) assays for drug discovery are performed in ArrayPlates. ArrayPlates are 96- well microtiter plates that contain a 16-element array at the bottom of each well. Each element within an array measures one analyte in a sample. A CCD imager records the quantitative chemiluminescent readout of all 1,536 elements in a 96-well plate simultaneously. Since array elements are reagent modifiable by the end-user, ArrayPlates can be adapted to a broad range of nucleic acid- and protein-based assays. Such multiplexed assays are rapidly established, flexible, robust, automation-friendly and cost-effective. Nucleic acid assays in ArrayPlates can detect DNA and RNA, including SNPs and ESTs. A multiplexed mRNA assay to measure the expression of 16 genes is described. The assay combines a homogeneous nuclease protection assay with subsequent probe immobilization to the array by means of a sandwich hybridization followed with chemiluminescent detection. This assay was used to examine cells grown and treated in microplates and avoided cloning, transfection, RNA insolation, reverse transcription, amplification and fluorochrome labeling. Standard deviations for the measurement of 16 genes ranged from 3 percent to 13 percent in samples of 30,000 cells. Such ArrayPlates transcription assays are useful in drug discovery and development for target validation, screening, lead optimization, metabolism and toxicity profiling. Chemiluminescent detection provides ArrayPlates assays with high signal-to-noise readout and simplifies imager requirements. Imaging a 2D surface that contains arrays simplifies lens requirements relative to imaging columns of liquid in microtiter plate wells. The Omix imager for ArrayPlates is described.

  6. Attenuation of tumor necrosis factor-induced endothelial cell cytotoxicity and neutrophil chemiluminescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, H.; Crowley, J.J.; Chan, J.C.

    Our laboratory has previously shown that the administration of tumor necrosis factor (TNF), a cytokine produced by activated mononuclear cells, to guinea pigs produces a syndrome similar to gram-negative sepsis or ARDS. Pentoxifylline (PTX), a methylxanthine, protects against TNF-induced and sepsis-induced acute lung injury in vivo. We now report on in vitro cellular studies of PMN-mediated cellular injury and its attenuation. We studied TNF-induced bovine pulmonary artery endothelial cell (EC) cytotoxicity both with and without PMN. A 51Cr release assay was used to measure EC damage. Further, we investigated PMN function in response to TNF by measuring chemiluminescence. Agents thatmore » attenuate EC damage and PMN activation were evaluated in the above assays. Results revealed that TNF causes EC injury (p less than 0.05) and PMN increase TNF-induced EC injury. Furthermore, PTX, aminophylline (AMPH), caffeine, and forskolin attenuate TNF-induced EC cytotoxicity only in the presence of PMN (p less than 0.05). Of interest, dibutyryl cAMP (DBcAMP) protects EC from TNF-induced injury both with and without PMN. Agents that may increase cAMP levels in PMN (PTX, DBcAMP, forskolin, isobutyl methylxanthine, and terbutaline) significantly attenuate TNF-induced PMN chemiluminescence (p less than 0.05). We conclude that TNF causes EC damage and PMN increase this damage. Furthermore, PTX, AMPH, caffeine, and forskolin can attenuate TNF-induced EC injury in the presence of PMN, whereas DBcAMP attenuates TNF-induced EC injury with and without PMN. In addition, agents that may increase intracellular cAMP levels in PMN can attenuate TNF-induced PMN chemiluminescence. Thus, these agents likely attenuate TNF-induced PMN-mediated EC injury through their inhibitory effects on PMN.« less

  7. Development and validation of a sensitive and fast chemiluminescent enzyme immunoassay for the detection of genetically modified maize.

    PubMed

    Roda, A; Mirasoli, M; Guardigli, M; Michelini, E; Simoni, P; Magliulo, M

    2006-03-01

    Proteins from the Cry 1 family, in particular Cry 1Ab, are commonly expressed in genetically modified Bt maize in order to control chewing insect pests. A sensitive chemiluminescent sandwich enzyme immunoassay for the detection of Cry1Ab protein from genetically modified Bt maize has been developed and validated. A Cry1Ab protein-specific antibody was immobilized on 96- or 384-well microtiter plates in order to capture the Cry1Ab toxin in the sample; the bound toxin was then detected by employing a second anti-Cry1Ab antibody and a horseradish peroxidase-labeled anti-antibody, followed by measurement of the enzyme activity with an enhanced chemiluminescent system. The chemiluminescent assay fulfilled all the requirements of accuracy and precision and exhibited limits of detection of a few pg mL(-1) Cry1Ab (3 or 5 pg mL(-1), depending on the assay format), which are significantly lower than that achievable using conventional colorimetric detection of peroxidase activity and also represent an improvement compared to previously developed Cry1Ab immunoassays. High-throughput analysis can be performed using the 384-well microtiter plate format immunoassay, which also allows one to reduce the consumption of samples and reagents. Validation of the assay, performed by analyzing certified reference materials, proved that the immunoassay is able to detect the presence of the Cry1Ab protein in certified reference samples containing as low as 0.1% of MON 810 genetically modified Bt maize. This value is below the threshold requiring mandatory labeling of foods containing genetically modified material according to the actual EU regulation.

  8. Negative interference by rheumatoid factor in alpha-fetoprotein chemiluminescent microparticle immunoassay.

    PubMed

    Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong

    2017-01-01

    Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime, laboratorians must remain alert to the negative interference by rheumatoid factor, and in some cases, pretreat rheumatoid factor-positive samples with blocking or absorbing reagents.

  9. Prospective validation of an automated chemiluminescence-based assay of renin and aldosterone for the work-up of arterial hypertension.

    PubMed

    Rossi, Gian Paolo; Ceolotto, Giulio; Rossitto, Giacomo; Seccia, Teresa Maria; Maiolino, Giuseppe; Berton, Chiara; Basso, Daniela; Plebani, Mario

    2016-09-01

    The availability of simple and accurate assays of plasma active renin (DRC) and aldosterone concentration (PAC) can improve the detection of secondary forms of arterial hypertension. Thus, we investigated the performance of an automated chemiluminescent assay for DRC and PAC in referred hypertensive patients. We prospectively recruited 260 consecutive hypertensive patients referred to an ESH Center for Hypertension. After exclusion of six protocol violations, 254 patients were analyzed: 67.3% had primary hypertension, 17.3% an aldosterone producing adenoma (APA), 11.4% idiopathic hyperaldosteronism (IHA), 2.4% renovascular hypertension (RVH), 0.8% familial hyperaldosteronism type 1 (FH-1), 0.4% apparent mineralocorticoid excess (AME), 0.4% a renin-producing tumor, and 3.9% were adrenalectomized APA patients. Bland-Altman plots and Deming regression were used to analyze results. The diagnostic accuracy (area under the curve, AUC of the ROC) of the DRC-based aldosterone-renin ratio (ARRCL) was compared with that of the PRA-based ARR (ARRRIA) using as reference the conclusive diagnosis of APA. At Bland-Altman plot, the DRC and PAC assay showed no bias as compared to the PRA and PAC assay. A tight relation was found between the DRC and the PRA values (concordance correlation coefficient=0.92, p<0.0001) and the PAC values measured with radioimmunoassay and chemiluminescence (concordance correlation coefficient=0.93, p<0.001). For APA identification the AUC of the ARRCL was higher than that of the ARRRIA [0.974 (95% CI 0.940-0.991) vs. 0.894 (95% CI 0.841-0.933), p=0.02]. This rapid automated chemiluminescent DRC/PAC assay performed better than validated PRA/PAC radioimmunoassays for the identification of APA in referred hypertensive patients.

  10. Rational design for enhancing inflammation-responsive in vivo chemiluminescence via nanophotonic energy relay to near-infrared AIE-active conjugated polymer.

    PubMed

    Seo, Young Hun; Singh, Ajay; Cho, Hong-Jun; Kim, Youngsun; Heo, Jeongyun; Lim, Chang-Keun; Park, Soo Young; Jang, Woo-Dong; Kim, Sehoon

    2016-04-01

    H2O2-specific peroxalate chemiluminescence is recognized as a potential signal for sensitive in vivo imaging of inflammation but the effect of underlying peroxalate-emitter energetics on its efficiency has rarely been understood. Here we report a simple nanophotonic way of boosting near-infrared chemiluminescence with no need of complicated structural design and synthesis of an energetically favored emitter. The signal enhancement was attained from the construction of a nanoparticle imaging probe (∼26 nm in size) by dense nanointegration of multiple molecules possessing unique photonic features, i.e., i) a peroxalate as a chemical fuel generating electronic excitation energy in response to inflammatory H2O2, ii) a low-bandgap conjugated polymer as a bright near-infrared emitter showing aggregation-induced emission (AIE), and iii) an energy gap-bridging photonic molecule that relays the chemically generated excitation energy to the emitter for its efficient excitation. From static and kinetic spectroscopic studies, a green-emissive BODIPY dye has proven to be an efficient relay molecule to bridge the energy gap between the AIE polymer and the chemically generated excited intermediate of H2O2-reacted peroxalates. The energy-relayed nanointegration of AIE polymer and peroxalate in water showed a 50-times boosted sensing signal compared to their dissolved mixture in THF. Besides the high H2O2 detectability down to 10(-9) M, the boosted chemiluminescence presented a fairly high tissue penetration depth (>12 mm) in an ex vivo condition, which enabled deep imaging of inflammatory H2O2 in a hair-covered mouse model of peritonitis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. The use of light-based (optical) detection systems as adjuncts in the detection of oral cancer and oral potentially malignant disorders: a systematic review.

    PubMed

    Rashid, A; Warnakulasuriya, S

    2015-05-01

    In recent decades, optical techniques utilising the principles of chemiluminescence and tissue autofluorescence have emerged to facilitate the early detection of any oral mucosal changes suspicious of cancer. To evaluate the effectiveness of devices that utilise the principles of chemiluminescence and tissue autofluorescence as adjuncts in the detection of oral cancer and oral potentially malignant disorders (OPMDs). A systematic review of the published literature to evaluate the effectiveness of the ViziLite(®) and ViziLite(®) Plus with toluidine blue, MicroLux™/DL and the VELscope™ as aids in the detection of oral cancer and OPMDs. Twenty-five primary studies published between 2004 and 2013 satisfied our criteria for selection - 13 utilised chemiluminescence and 12 tissue autofluorescence. Some had utilised both study methods on the same population. Chemiluminescence shows good sensitivity at detecting any OPMDs and oral cancer. However, it preferentially detects leukoplakia and may fail to spot red patches. The additive use of toluidine blue may improve specificity. Tissue autofluorescence is sensitive at detecting white, red and white and red patches, and the area of fluorescence visualisation loss (FVL) often extends beyond the clinically visible lesion. However, in addition to OPMDs, VELScope may detect erythematous lesions of benign inflammation resulting in false-positive test results. There is limited evidence for their use in primary care, and these tools are better suited to specialist clinics in which there is a higher prevalence of disease and where experienced clinicians may better discriminate between benign and malignant lesions. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Determination of rutin and quercetin in Chinese herbal medicine by ionic liquid-based pressurized liquid extraction-liquid chromatography-chemiluminescence detection.

    PubMed

    Wu, Hongwei; Chen, Meilan; Fan, Yunchang; Elsebaei, Fawzi; Zhu, Yan

    2012-01-15

    A novel ionic liquid-based pressurized liquid extraction (IL-PLE) procedure coupled with high performance liquid chromatography (HPLC) tandem chemiluminescence (CL) detection capable of quantifying trace amounts of rutin and quercetin in four Chinese medicine plants including Flos sophorae Immaturus, Crateagus pinnatifida Bunge, Hypericum japonicum Thunb and Folium Mori was described in this paper. To avoid environmental pollution and toxicity to the operators, ionic liquids (ILs), 1-alkyl-3-methylimidazolium chloride ([C(n)mim][Cl]) aqueous solutions were used in the PLE procedure as extractants replacing traditional organic solvents. In addition, chemiluminescence detection was utilized for its minimal interference from endogenous components of complex matrix. Parameters affecting extraction and analysis were carefully optimized. Compared with the conventional ultrasonic-assisted extraction (UAE) and heat-reflux extraction (HRE), the optimized method achieved the highest extraction efficiency in the shortest extraction time with the least solvent consumption. The applicability of the proposed method to real sample was confirmed. Under the optimized conditions, good reproducibility of extraction performance was obtained and good linearity was observed with correlation coefficients (r) between 0.9997 and 0.9999. The detection limits of rutin and quercetin (LOD, S/N=3) were 1.1×10(-2)mg/L and 3.8×10(-3)mg/L, respectively. The average recoveries of rutin and quercetin for real samples were 93.7-105% with relative standard deviation (RSD) lower than 5.7%. To the best of our knowledge, this paper is the first contribution to utilize a combination of IL-PLE with chemiluminescence detection. And the experimental results indicated that the proposed method shows a promising prospect in extraction and determination of rutin and quercetin in medicinal plants. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Assessment of the presence of mucosal human papillomaviruses in malignant melanomas using combined fluorescent in situ hybridization and chemiluminescent immunohistochemistry.

    PubMed

    Ambretti, S; Venturoli, S; Mirasoli, M; La Placa, M; Bonvicini, F; Cricca, M; Zerbini, M; Roda, A; Musiani, M

    2007-01-01

    The vast majority of studies aimed at detecting human papillomavirus (HPV) DNA in skin cancer have used sensitive polymerase chain reaction (PCR) methods but the PCR technique, despite its high sensitivity, is not suitable to ascertain whether (i) the presence of HPV can be related only to few cells harbouring the virus, (ii) the presence of HPV is due to a tumour surface contamination and (iii) the presence of HPV is localized in cancer cells, rather than in normal keratinocytes present in the tumour biopsy. In a recent work we have found mucosal high-risk (HR) HPV genotypes in primary melanoma by PCR. To localize mucosal HR-HPV nucleic acids and tumoural melanocytic marker in the same sections of primary melanoma samples in order to understand the relationship between HPVs and melanoma cells. We have developed a very sensitive method that combines an enzyme-amplified fluorescent in situ hybridization (ISH) for the detection of HPV nucleic acids (types 16 and 18) with a chemiluminescent immunohistochemistry (IHC) method for the detection of the tumoural melanocytic marker HMB-45 sequentially in the same section. Digital images of fluorescent ISH and chemiluminescent IHC were separately recorded, assigned different colours and merged using specific software for image analysis. The combined fluorescent ISH and chemiluminescent IHC demonstrated a sharp colocalization (in the range 60-80%) of HPV nucleic acids and melanoma marker inside the same sections of melanoma biopsies, with a strong specificity and sensitivity. The strong colocalization of mucosal HR-HPV nucleic acids and HMB-45 melanocytic marker emphasized that viral nucleic acids were specifically present in melanoma cells and supported a possible active role of HPV in malignant melanoma.

  14. GAS PHASE SELECTIVE PHOTOXIDATION OF ALCOHOLS USING LIGHT-ACTIVATED TITANIUM DIOXIDE AND MOLECULAR OXYGEN

    EPA Science Inventory

    Gas Phase Selective Oxidation of Alcohols Using Light-Activated Titanium Dioxide and Molecular Oxygen

    Gas phase selective oxidations of various primary and secondary alcohols are studied in an indigenously built stainless steel up-flow photochemical reactor using ultravi...

  15. Entrapment of Hydrate-coated Gas Bubbles into Oil and Separation of Gas and Hydrate-film; Seafloor Experiments with ROV

    NASA Astrophysics Data System (ADS)

    Hiruta, A.; Matsumoto, R.

    2015-12-01

    We trapped gas bubbles emitted from the seafloor into oil-containing collector and observed an unique phenomena. Gas hydrate formation needs water for the crystal lattice; however, gas hydrates in some areas are associated with hydrophobic crude oil or asphalt. In order to understand gas hydrate growth in oil-bearing sediments, an experiment with cooking oil was made at gas hydrate stability condition. We collected venting gas bubbles into a collector with canola oil during ROV survey at a gas hydrate area in the eastern margin of the Sea of Japan. When the gas bubbles were trapped into collector with oil, gas phase appeared above the oil and gas hydrates, between oil and gas phase. At this study area within gas hydrate stability condition, control experiment with oil-free collector suggested that gas bubbles emitted from the seafloor were quickly covered with gas hydrate film. Therefore it is improbable that gas bubbles entered into the oil phase before hydrate skin formation. After the gas phase formation in oil-containing collector, the ROV floated outside of hydrate stability condition for gas hydrate dissociation and re-dived to the venting site. During the re-dive within hydrate stability condition, gas hydrate was not formed. The result suggests that moisture in the oil is not enough for hydrate formation. Therefore gas hydrates that appeared at the oil/gas phase boundary were already formed before bubbles enter into the oil. Hydrate film is the only possible origin. This observation suggests that hydrate film coating gas hydrate was broken at the sea water/oil boundary or inside oil. Further experiments may contribute for revealing kinetics of hydrate film and formation. This work was a part of METI (Ministry of Economy, Trade and Industry)'s project entitled "FY2014 Promoting research and development of methane hydrate". We also appreciate support of AIST (National Institute of Advanced Industrial Science and Technology).

  16. Modelling Phase Transition Phenomena in Fluids

    DTIC Science & Technology

    2015-07-01

    Sublimation line r @@I Triple point ? Vapourisation liner @@I Critical point -Fusion line Solid Liquid Gas Figure 1: Schematic of a phase diagram means that the...velocity field can be set zero, and only the balance of energy constitutes the Stefan model. In contrast to this the liquid - gas phase transitions...defined by requiring that the phase-transition line is crossed in a direction from solid to liquid or from liquid to gas (vapour) phases. The term T∗ δs is

  17. DSMC simulation of two-phase plume flow with UV radiation

    NASA Astrophysics Data System (ADS)

    Li, Jie; Liu, Ying; Wang, Ning; Jin, Ling

    2014-12-01

    Rarefied gas-particle two-phase plume in which the phase of particles is liquid or solid flows from a solid propellant rocket of hypersonic vehicle flying at high altitudes, the aluminum oxide particulates not only impact the rarefied gas flow properties, but also make a great difference to plume radiation signature, so the radiation prediction of the rarefied gas-particle two-phase plume flow is very important for space target detection of hypersonic vehicles. Accordingly, this project aims to study the rarefied gas-particle two-phase flow and ultraviolet radiation (UV) characteristics. Considering a two-way interphase coupling of momentum and energy, the direct simulation Monte Carlo (DSMC) method is developed for particle phase change and the particle flow, including particulate collision, coalescence as well as separation, and a Monte Carlo ray trace model is implemented for the particulate UV radiation. A program for the numerical simulation of the gas-particle two-phase flow and radiation in which the gas flow nonequilibrium is strong is implemented as well. Ultraviolet radiation characteristics of the particle phase is studied based on the calculation of the flow field coupled with the radiation calculation, the radiation model for different size particles is analyzed, focusing on the effects of particle emission, absorption, scattering as well as the searchlight emission of the nozzle. A new approach may be proposed to describe the rarefied gas-particle two-phase plume flow and radiation transfer characteristics in this project.

  18. Deliberate and Accidental Gas-Phase Alkali Doping of Chalcogenide Semiconductors: Cu(In,Ga)Se2

    PubMed Central

    Colombara, Diego; Berner, Ulrich; Ciccioli, Andrea; Malaquias, João C.; Bertram, Tobias; Crossay, Alexandre; Schöneich, Michael; Meadows, Helene J.; Regesch, David; Delsante, Simona; Gigli, Guido; Valle, Nathalie; Guillot, Jérome; El Adib, Brahime; Grysan, Patrick; Dale, Phillip J.

    2017-01-01

    Alkali metal doping is essential to achieve highly efficient energy conversion in Cu(In,Ga)Se2 (CIGSe) solar cells. Doping is normally achieved through solid state reactions, but recent observations of gas-phase alkali transport in the kesterite sulfide (Cu2ZnSnS4) system (re)open the way to a novel gas-phase doping strategy. However, the current understanding of gas-phase alkali transport is very limited. This work (i) shows that CIGSe device efficiency can be improved from 2% to 8% by gas-phase sodium incorporation alone, (ii) identifies the most likely routes for gas-phase alkali transport based on mass spectrometric studies, (iii) provides thermochemical computations to rationalize the observations and (iv) critically discusses the subject literature with the aim to better understand the chemical basis of the phenomenon. These results suggest that accidental alkali metal doping occurs all the time, that a controlled vapor pressure of alkali metal could be applied during growth to dope the semiconductor, and that it may have to be accounted for during the currently used solid state doping routes. It is concluded that alkali gas-phase transport occurs through a plurality of routes and cannot be attributed to one single source. PMID:28233864

  19. Deliberate and Accidental Gas-Phase Alkali Doping of Chalcogenide Semiconductors: Cu(In,Ga)Se2.

    PubMed

    Colombara, Diego; Berner, Ulrich; Ciccioli, Andrea; Malaquias, João C; Bertram, Tobias; Crossay, Alexandre; Schöneich, Michael; Meadows, Helene J; Regesch, David; Delsante, Simona; Gigli, Guido; Valle, Nathalie; Guillot, Jérome; El Adib, Brahime; Grysan, Patrick; Dale, Phillip J

    2017-02-24

    Alkali metal doping is essential to achieve highly efficient energy conversion in Cu(In,Ga)Se 2 (CIGSe) solar cells. Doping is normally achieved through solid state reactions, but recent observations of gas-phase alkali transport in the kesterite sulfide (Cu 2 ZnSnS 4 ) system (re)open the way to a novel gas-phase doping strategy. However, the current understanding of gas-phase alkali transport is very limited. This work (i) shows that CIGSe device efficiency can be improved from 2% to 8% by gas-phase sodium incorporation alone, (ii) identifies the most likely routes for gas-phase alkali transport based on mass spectrometric studies, (iii) provides thermochemical computations to rationalize the observations and (iv) critically discusses the subject literature with the aim to better understand the chemical basis of the phenomenon. These results suggest that accidental alkali metal doping occurs all the time, that a controlled vapor pressure of alkali metal could be applied during growth to dope the semiconductor, and that it may have to be accounted for during the currently used solid state doping routes. It is concluded that alkali gas-phase transport occurs through a plurality of routes and cannot be attributed to one single source.

  20. Effect of measurement protocol on organic aerosol measurements of exhaust emissions from gasoline and diesel vehicles

    NASA Astrophysics Data System (ADS)

    Kim, Youngseob; Sartelet, Karine; Seigneur, Christian; Charron, Aurélie; Besombes, Jean-Luc; Jaffrezo, Jean-Luc; Marchand, Nicolas; Polo, Lucie

    2016-09-01

    Exhaust emissions of semi-volatile organic compounds (SVOC) from passenger vehicles are usually estimated only for the particle phase via the total particulate matter measurements. However, they also need to be estimated for the gas phase, as they are semi-volatile. To better estimate SVOC emission factors of passenger vehicles, a measurement campaign using a chassis dynamometer was conducted with different instruments: (1) a constant volume sampling (CVS) system in which emissions were diluted with filtered air and sampling was performed on filters and polyurethane foams (PUF) and (2) a Dekati Fine Particle Sampler (FPS) in which emissions were diluted with purified air and sampled with on-line instruments (PTR-ToF-MS, HR-ToF-AMS, MAAP, CPC). Significant differences in the concentrations of organic carbon (OC) measured by the instruments are observed. The differences can be explained by sampling artefacts, differences between (1) the time elapsed during sampling (in the case of filter and PUF sampling) and (2) the time elapsed from emission to measurement (in the case of on-line instruments), which vary from a few seconds to 15 min, and by the different dilution factors. To relate elapsed times and measured concentrations of OC, the condensation of SVOC between the gas and particle phases is simulated with a dynamic aerosol model. The simulation results allow us to understand the relation between elapsed times and concentrations in the gas and particle phases. They indicate that the characteristic times to reach thermodynamic equilibrium between gas and particle phases may be as long as 8 min. Therefore, if the elapsed time is less than this characteristic time to reach equilibrium, gas-phase SVOC are not at equilibrium with the particle phase and a larger fraction of emitted SVOC will be in the gas phase than estimated by equilibrium theory, leading to an underestimation of emitted OC if only the particle phase is considered or if the gas-phase SVOC are estimated by equilibrium theory. Current European emission inventories for passenger cars do not yet estimate gas-phase SVOC emissions, although they may represent 60% of total emitted SVOC (gas + particle phases).

  1. Formation of complex organic molecules in cold objects: the role of gas-phase reactions

    NASA Astrophysics Data System (ADS)

    Balucani, Nadia; Ceccarelli, Cecilia; Taquet, Vianney

    2015-04-01

    While astrochemical models are successful in reproducing many of the observed interstellar species, they have been struggling to explain the observed abundances of complex organic molecules. Current models tend to privilege grain surface over gas-phase chemistry in their formation. One key assumption of those models is that radicals trapped in the grain mantles gain mobility and react on lukewarm ( ≳ 30 K) dust grains. Thus, the recent detections of methyl formate (MF) and dimethyl ether (DME) in cold objects represent a challenge and may clarify the respective role of grain-surface and gas-phase chemistry. We propose here a new model to form DME and MF with gas-phase reactions in cold environments, where DME is the precursor of MF via an efficient reaction overlooked by previous models. Furthermore, methoxy, a precursor of DME, is also synthesized in the gas phase from methanol, which is desorbed by a non-thermal process from the ices. Our new model reproduces fairly well the observations towards L1544. It also explains, in a natural way, the observed correlation between DME and MF. We conclude that gas-phase reactions are major actors in the formation of MF, DME and methoxy in cold gas. This challenges the exclusive role of grain-surface chemistry and favours a combined grain-gas chemistry.

  2. Heterogeneous reactivity of sea spray particles during the CalNex field campaign: Insight from single particle measurements and correlations with gas phase measurements

    NASA Astrophysics Data System (ADS)

    Gaston, C. J.; Riedel, T. P.; Thornton, J. A.; Wagner, N.; Brown, S. S.; Quinn, P.; Bates, T. S.; Prather, K. A.

    2011-12-01

    Sea spray particles are ubiquitous in marine environments. Heterogeneous reactions between sea spray particles and gas phase pollutants, such as HNO3(g), and N2O5(g), alter particle composition by displacing particulate phase halogens in sea spray and releasing these halogen species into the gas phase; these halogen-containing gas phase species play a significant role in tropospheric ozone production. Measurements of both gas phase and particle phase species on board the R/V Atlantis during the CalNEX 2010 field campaign provided an opportunity to examine the impact of heterogeneous reactivity of marine aerosols along the California coast. During the cruise, coastal measurements were made near the Santa Monica and Port of Los Angeles regions to monitor the chemical processing of marine aerosols. Sea spray particles were analyzed since these particles were the major chloride-containing particles detected. Real-time single particle measurements made using an aerosol time-of-flight mass spectrometer (ATOFMS) revealed the nocturnal processing of sea spray particles through the loss of particulate chloride and a simultaneous gain in particulate nitrate. Gas phase measurements are consistent with the particle phase observations: As N2O5(g) levels rose overnight, the production of ClNO2(g) coincided with the decrease in particulate chloride. These observations provide unique insight into heterogeneous reactivity from both a gas and particle phase perspective. Results from these measurements can be used to better constrain the rate of heterogeneous reactions on sea spray particles.

  3. Quantification of plasma myo-inositol using gas chromatography-mass spectrometry.

    PubMed

    Guo, Jin; Shi, Yingfei; Xu, Chengbao; Zhong, Rugang; Zhang, Feng; Zhang, Ting; Niu, Bo; Wang, Jianhua

    2016-09-01

    Myo-inositol (MI) deficiency is associated with an increased risk for neural tube defects (NTDs), mental disorders and metabolic diseases. We developed a gas chromatography-mass spectrometry (GC-MS) method to detect MI in human plasma, which was accurate, relatively efficient and convenient for clinical application. An external standard method was used for determination of plasma MI. Samples were analyzed by GC-MS after derivatization. The stable-isotope labeled internal standard approach was used to validate the method's accuracy. Alpha fetal protein (AFP) was detected by chemiluminescence immunoassay. The method was validated by determining the linearity, sensitivity and recovery rate. There was a good agreement between the internal standard approach and the present method. The NTD-affected pregnancies showed lower plasma MI (P=0.024) and higher AFP levels (P=0.001) than control. Maternal MI level showed a better discrimination in spina bifida subgroup, while AFP level showed a better discrimination in anencephaly subgroup after stratification analysis. We developed a sensitive and reliable method for the detection of clinical plasma MI, which might be a marker for NTDs screening, and established fundamental knowledge for clinical diagnosis and prevention for the diseases related to disturbed MI metabolism. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. CO Emission from an Impinging Non-Premixed Flame

    PubMed Central

    Chien, Y.C.; Escofet-Martin, D.; Dunn-Rankin, D.

    2017-01-01

    Carbon monoxide (CO) results from the incomplete oxidation of hydrocarbon fuels. While CO can be desirable in some syngas processes, it is a dangerous emission from fires, gas heaters, gas stoves, or furnaces where insufficient oxygen in the core reaction prevents complete oxidation of fuel to carbon dioxide and water, particularly when the reaction is interrupted by interaction with relatively cool solid boundaries. This research examines the physico-thermo-chemical processes responsible for carbon monoxide release from a small laminar non-premixed methane/air flame impinging on a nearby surface. We measure the changes in CO emission as correlated with variations in flame structure observed using planar laser induced fluorescence (PLIF of OH and 2-photon CO), and two-line OH PLIF thermometry, as a function of burner-to-plate distance. In particular, this work combines the use of OH and CO PLIF, and PLIF thermometry to describe the relative locations of the CO rich region, the peak heat release zone as indicated by chemiluminescence and OH gradients, and the extended oxidative zone in the impinging flames. The results show that CO release correlates strongly with stagnating flow-driven changes in the location and extent of high concentration regions of OH in surface-impinging diffusion flames. PMID:28989179

  5. High-speed laser diagnostics for the study of flame dynamics in a lean premixed gas turbine model combustor

    NASA Astrophysics Data System (ADS)

    Boxx, Isaac; Arndt, Christoph M.; Carter, Campbell D.; Meier, Wolfgang

    2012-03-01

    A series of measurements was taken on two technically premixed, swirl-stabilized methane-air flames (at overall equivalence ratios of ϕ = 0.73 and 0.83) in an optically accessible gas turbine model combustor. The primary diagnostics used were combined planar laser-induced fluorescence of the OH radical and stereoscopic particle image velocimetry (PIV) with simultaneous repetition rates of 10 kHz and a measurement duration of 0.8 s. Also measured were acoustic pulsations and OH chemiluminescence. Analysis revealed strong local periodicity in the thermoacoustically self-excited (or ` noisy') flame (ϕ = 0.73) in the regions of the flow corresponding to the inner shear layer and the jet-inflow. This periodicity appears to be the result of a helical precessing vortex core (PVC) present in that region of the combustor. The PVC has a precession frequency double (at 570 Hz) that of the thermo-acoustic pulsation (at 288 Hz). A comparison of the various data sets and analysis techniques applied to each flame suggests a strong coupling between the PVC and the thermo-acoustic pulsation in the noisy flame. Measurements of the stable (` quiet') flame (ϕ = 0.83) revealed a global fluctuation in both velocity and heat-release around 364 Hz, but no clear evidence of a PVC.

  6. Superamphiphobic Silicon-Nanowire-Embedded Microsystem and In-Contact Flow Performance of Gas and Liquid Streams.

    PubMed

    Ko, Dong-Hyeon; Ren, Wurong; Kim, Jin-Oh; Wang, Jun; Wang, Hao; Sharma, Siddharth; Faustini, Marco; Kim, Dong-Pyo

    2016-01-26

    Gas and liquid streams are invariably separated either by a solid wall or by a membrane for heat or mass transfer between the gas and liquid streams. Without the separating wall, the gas phase is present as bubbles in liquid or, in a microsystem, as gas plugs between slugs of liquid. Continuous and direct contact between the two moving streams of gas and liquid is quite an efficient way of achieving heat or mass transfer between the two phases. Here, we report a silicon nanowire built-in microsystem in which a liquid stream flows in contact with an underlying gas stream. The upper liquid stream does not penetrate into the lower gas stream due to the superamphiphobic nature of the silicon nanowires built into the bottom wall, thereby preserving the integrity of continuous gas and liquid streams, although they are flowing in contact. Due to the superamphiphobic nature of silicon nanowires, the microsystem provides the best possible interfacial mass transfer known to date between flowing gas and liquid phases, which can achieve excellent chemical performance in two-phase organic syntheses.

  7. Development of ochratoxin a in cereal by chemiluminescence enzyme immunoassay

    NASA Astrophysics Data System (ADS)

    Li, Min; Liu, Renrong; Zhu, Lixin; Chen, Zhenzhen

    2017-11-01

    A rapid, simple and sensitive chemiluminescence enzyme immunoassay method (CLEIA) was established to detect ochratoxin A (OTA) in cereal. Optimal conditions including antibody dilution ratio and enzyme conjugate, ionic strength, pH value and organic solvent. Established indirect competition inhibition curve to determine the linear working range, detection limit and recovery rate. Results: The 50% inhibitory concentration and the detection limit of the CLEIA were78.8pg/mL and 14.86 pg/mL, respectively, with a linear range of 0.015-0.4ng/mL. At 1∼4μpg/kg fortified levels in wheat, mean recoveries ranged from 67.47% to100.35%.

  8. Flame Chemiluminescence Rate Constants for Quantitative Microgravity Combustion Diagnostics

    NASA Technical Reports Server (NTRS)

    Luque, Jorge; Smith, Gregory P.; Jeffries, Jay B.; Crosley, David R.; Weiland, Karen (Technical Monitor)

    2001-01-01

    Absolute excited state concentrations of OH(A), CH(A), and C2(d) were determined in three low pressure premixed methane-air flames. Two dimensional images of chemiluminescence from these states were recorded by a filtered CCD camera, processed by Abel inversion, and calibrated against Rayleigh scattering, Using a previously validated 1-D flame model with known chemistry and excited state quenching rate constants, rate constants are extracted for the reactions CH + O2 (goes to) OH(A) + CO and C2H + O (goes to) CH(A) + CO at flame temperatures. Variations of flame emission intensities with stoichiometry agree well with model predictions.

  9. Molecular Fluorescence, Phosphorescence, and Chemiluminescence Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powe, Aleeta; Das, Susmita; Lowry, Mark

    This review covers the 2 year period since our last review (1) from January 2008 through December 2009. A computer search of Chemical Abstracts provided most of the references for this review. A search for documents written in English containing the terms fluorescence or phosphorescence or chemiluminescence published in 2008-2009 resulted in more than 100 000 hits. An initial screening reduced this number to approximately 23 000 publications that were considered for inclusion in this review. Key word searches of this subset provided subtopics of manageable size. Other citations were found through individual searches by the various authors who wrotemore » a particular section of this review.« less

  10. Effect of CoQ homologues on reactive oxygen generation by mitochondria.

    PubMed

    Imada, Isuke; Sato, Eisuke F; Kira, Yukimi; Inoue, Masayasu

    2008-01-01

    Effect of CoQ compounds (Qs) on reactive oxygen (ROS) generation by mitochondrial complex I was studied using rat liver mitochondria and chemiluminescence probe L012. Kinetic analysis revealed that short chain Qs, such as Q2 and idebenone enhanced ROS generation by mitochondrial NADH oxidase system by a succinate-inhibitable mechanism. Lipid peroxidation in mitochondrial membranes induced by NADH and iron was inhibited by short chain Qs. The inhibitory activity was enhanced by co-oxidation of succinate as determined by chemiluminescence method and by electron spin resonance spectroscopy. These results suggested that the reduced form of short chain Qs inhibited mitochondrial ROS generation and lipid peroxidation.

  11. Highly specific detection of H2O2-dependent luminol chemiluminescence in stimulated human leukocytes using polyvinyl films.

    PubMed

    Moriguchi, K; Ohno, N; Ogawa, T; Hirai, K

    1999-01-01

    When human polymorphonuclear leukocytes (PMN) were attached to glass coverslips, cells always spread and formed reactive oxygen species prior to any experimental stimulation. To avoid this, a polyvinylidine chloride film was used as an inactive substance to place the cells. Cells engaged in phagocytosis on the film exhibited a specific H2O2-mediated luminol chemiluminescence (LCL) at the cell-particle interface; the cells stimulated with 12-O-tetradecanoylphorbol-13-acetate became aggregated and the LCL was observed at the cell-cell contact. These results corresponded well with those obtained by an electron microscopic H2O2-demonstration method.

  12. Detection of ochratoxin A (OTA) in coffee using chemiluminescence resonance energy transfer (CRET) aptasensor.

    PubMed

    Jo, Eun-Jung; Mun, Hyoyoung; Kim, Su-Ji; Shim, Won-Bo; Kim, Min-Gon

    2016-03-01

    We report a chemiluminescence resonance energy transfer (CRET) aptasensor for the detection of ochratoxin A (OTA) in roasted coffee beans. The aptamer sequences used in this study are 5'-DNAzyme-Linker-OTA aptamer-3'-dabcyl. Dabcyl at the end of the OTA aptamer region plays as a quencher in CRET aptasensor. When hemin and OTA are added, the dabcyl-labeled OTA aptamer approaches to the G-quadruplex-hemin complex by formation of the G-quadruplex-OTA complex. The G-quadruplex-hemin complexes possess horseradish peroxidase (HRP)-like activity, and therefore, the HRP-mimicking DNAzyme (HRPzyme) catalyzes peroxidation in the presence of luminol and H2O2. Resonance energy transfer between luminol (donor) and dabcyl (acceptor) enables quenching of chemiluminescence signals. The signal decreases with increasing the concentration of OTA within the range of 0.1-100ngmL(-1) (limit of detection 0.22ngmL(-1)), and the level of recovery of the respective 1ngmL(-1) and 10ngmL(-1) spiked coffee samples was 71.5% and 93.3%. These results demonstrated the potential of the proposed method for OTA analysis in diverse foods. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. A sensitive gold nanoparticles sensing platform based on resonance energy transfer for chemiluminescence light on detection of biomolecules.

    PubMed

    Qin, Guoxing; Zhao, Shulin; Huang, Yong; Jiang, Jing; Liu, Yi-Ming

    2013-08-15

    In this article, we report a gold nanoparticles (AuNPs) sensing platform based on chemiluminescence resonance energy transfer (CRET) for light on detection of biomolecules. In designing such a CRET-based biosensing platform, the aptamer was first covalently labeled with a chemiluminescent reagent, N-(4-aminobutyl)-N-ethylisoluminol (ABEI). The ABEI labeled aptamer was then hybridized with AuNPs functionalized ssDNA which was complementary to the aptamer, obtaining the aptasensor. The CRET between ABEI and AuNPs in the aptasensor led to the CL quenching of ABEI. In the presence of a target analyte, it formed a complex with aptamer, and released ABEI-aptamer from AuNPs surface that resulted in CL recovery of ABEI. To test this design, a thrombin (used as a model analyte) aptasensor was prepared and evaluated. The results indicate that the proposed approach is simple and provided a linear range of 50-550 pM for thrombin detection with a detection limit of 15 pM. This new methodology can be easily extended to assay other biomolecules by simply changing the recognition sequence with the substrate aptamer. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. The importance of chain length for the polyphosphate enhancement of acidic potassium permanganate chemiluminescence.

    PubMed

    Holland, Brendan J; Adcock, Jacqui L; Nesterenko, Pavel N; Peristyy, Anton; Stevenson, Paul G; Barnett, Neil W; Conlan, Xavier A; Francis, Paul S

    2014-09-09

    Sodium polyphosphate is commonly used to enhance chemiluminescence reactions with acidic potassium permanganate through a dual enhancement mechanism, but commercially available polyphosphates vary greatly in composition. We have examined the influence of polyphosphate composition and concentration on both the dual enhancement mechanism of chemiluminescence intensity and the stability of the reagent under analytically useful conditions. The average chain length (n) provides a convenient characterisation, but materials with similar values can exhibit markedly different distributions of phosphate oligomers. There is a minimum polyphosphate chain length (∼6) required for a large enhancement of the emission intensity, but no further advantage was obtained using polyphosphate materials with much longer average chain lengths. Providing there is a sufficient average chain length, the optimum concentration of polyphosphate is dependent on the analyte and in some cases, may be lower than the quantities previously used in routine detection. However, the concentration of polyphosphate should not be lowered in permanganate reagents that have been partially reduced to form high concentrations of the key manganese(III) co-reactant, as this intermediate needs to be stabilised to prevent formation of insoluble manganese(IV). Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence.

    PubMed Central

    Crouch, C F

    1995-01-01

    AIMS--To evaluate the clinical performance of enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence. METHODS--Classification of routine clinical samples from the originating laboratories was compared with that obtained using the chemiluminescence based assays. Resolution of discordant results was achieved by testing in alternative enzyme immunoassays (IgM) or by an independent laboratory using the dye test (IgG). RESULTS--Compared with resolved data, the IgM assay was found to be highly specific (100%) with a cut off selected to give optimal performance with respect to both the early detection of specific IgM and the detection of persistent levels of specific IgM (sensitivity 98%). Compared with resolved data, the IgG assay was shown to have a sensitivity and a specificity of 99.4%. CONCLUSIONS--The Amerlite Toxo IgM assay possesses high levels of sensitivity and specificity. Assay interference due to rheumatoid factor like substances is not a problem. The Amerlite Toxo IgG assay possesses good sensitivity and specificity, but is less sensitive for the detection of seroconversion than methods detecting both IgG and IgM. PMID:7560174

  16. A highly sensitive capillary electrophoresis immunoassay strategy based on dual-labeled gold nanoparticles enhancing chemiluminescence for the detection of prostate-specific antigen.

    PubMed

    Li, Shuting; Shi, Min; Zhao, Jingjin; Zhang, Liangliang; Huang, Yong; Zhao, Shulin

    2017-07-01

    An enzyme and antibody dual labeled gold nanoparticles enhancing chemiluminescence strategy was developed for highly sensitive CE immunoassay (IA) of prostate-specific antigen (PSA). In this work, gold nanoparticles were labeled with horseradish peroxidase and antiprostate specific antigen-antibody, and used as the marker (Ab * ). After PSA (antigen, Ag) was added into the system, a noncompetitive immune reaction was happen between Ab * and Ag to form an immune complex (Ag-Ab * ). Subsequently, the obtained Ag-Ab * and unreacted Ab * were separated by CE, and the chemiluminescence intensity of Ag-Ab * was used to estimate PSA concentration. The calibration curve showed a good linearity in the range of 0.25-10 ng/mL. Based on a S/N of 3, the detection limit for PAS was estimated to be 0.092 ng/mL. Proposed CE method was applied for PSA quantification in human serum samples from healthy volunteers and patients with prostate cancer. The obtained results demonstrated that the proposed CE method may serve as an alternative tool for clinical analysis of PSA. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Chemistry in the Dusty Coma of Comet Hale-Bopp

    NASA Astrophysics Data System (ADS)

    Boice, D. C.; Cochran, A. L.; Disanti, M. A.; Huebner, W. F.

    1998-09-01

    Recent progress on a multifluid, hydrodynamic model is presented for the dusty gas flow in the inner coma of comet Hale-Bopp at several heliocentric distances. The simulations are based on a 1-D neutral coma model with detailed photo and gas-phase chemistry and dust entrainment by the gas, a separate energy balance for the electrons, separate flow of the neutral gas, fast neutral atomic and molecular hydrogen, and dust entrainment with fragmentation. The model accounts for three sources of gas release: sublimation from surface ices, transport of gas from subsurface regions through the surface, and release of gas from dust in the coma. This permits a consistent study of the importance and strength of each possible source for a variety of gas-phase species. The simulations allow a study of the changes with heliocentric distance of features within a cometary coma, e.g., spatial distributions of gas-phase species and dust of various sizes and the velocity and temperature profiles. In particular, the model is used to probe spatial distributions of gas-phase species (e.g., CN, CH, C_3, C_2, HCN, HNC, CO) and dust, and the velocity and temperature structure to understand the complex gas-phase chemistry that occurs in the inner coma. Comparisons with observations are made where available to characterize the environment surrounding comet Hale-Bopp and to aid in assimilating a variety of diverse observations of this unique comet.

  18. The effect of dry and wet deposition of condensable vapors on secondary organic aerosols concentrations over the continental US

    NASA Astrophysics Data System (ADS)

    Knote, C.; Hodzic, A.; Jimenez, J. L.

    2015-01-01

    The effect of dry and wet deposition of semi-volatile organic compounds (SVOCs) in the gas phase on the concentrations of secondary organic aerosol (SOA) is reassessed using recently derived water solubility information. The water solubility of SVOCs was implemented as a function of their volatility distribution within the WRF-Chem regional chemistry transport model, and simulations were carried out over the continental United States for the year 2010. Results show that including dry and wet removal of gas-phase SVOCs reduces annual average surface concentrations of anthropogenic and biogenic SOA by 48 and 63% respectively over the continental US. Dry deposition of gas-phase SVOCs is found to be more effective than wet deposition in reducing SOA concentrations (-40 vs. -8% for anthropogenics, and -52 vs. -11% for biogenics). Reductions for biogenic SOA are found to be higher due to the higher water solubility of biogenic SVOCs. The majority of the total mass of SVOC + SOA is actually deposited via the gas phase (61% for anthropogenics and 76% for biogenics). Results are sensitive to assumptions made in the dry deposition scheme, but gas-phase deposition of SVOCs remains crucial even under conservative estimates. Considering reactivity of gas-phase SVOCs in the dry deposition scheme was found to be negligible. Further sensitivity studies where we reduce the volatility of organic matter show that consideration of gas-phase SVOC removal still reduces average SOA concentrations by 31% on average. We consider this a lower bound for the effect of gas-phase SVOC removal on SOA concentrations. A saturation effect is observed for Henry's law constants above 108 M atm-1, suggesting an upper bound of reductions in surface level SOA concentrations by 60% through removal of gas-phase SVOCs. Other models that do not consider dry and wet removal of gas-phase SVOCs would hence overestimate SOA concentrations by roughly 50%. Assumptions about the water solubility of SVOCs made in some current modeling systems (H* = H* (CH3COOH); H* = 105 M atm-1; H* = H* (HNO3)) still lead to an overestimation of 35%/25%/10% compared to our best estimate.

  19. Concurrence of aqueous and gas phase contamination of groundwater in the Wattenberg oil and gas field of northern Colorado.

    PubMed

    Li, Huishu; Son, Ji-Hee; Carlson, Kenneth H

    2016-01-01

    The potential impact of rapid development of unconventional oil and natural gas resources using hydraulic fracturing and horizontal drilling on regional groundwater quality has received significant attention. Major concerns are methane or oil/gas related hydrocarbon (such as TPHs, BTEX including benzene, toluene, ethybenzene and xylene) leaks into the aquifer due to the failure of casing and/or stray gas migration. Previously, we investigated the relationship between oil and gas activity and dissolved methane concentration in a drinking water aquifer with the major finding being the presence of thermogenic methane contamination, but did not find detectable concentrations of TPHs or BTEX. To understand if aqueous and gas phases from the producing formation were transported concurrently to drinking water aquifers without the presence of oil/gas related hydrocarbons, the ionic composition of three water groups was studied: (1) uncontaminated deep confined aquifer, (2) suspected contaminated groundwater - deep confined aquifer containing thermogenic methane, and (3) produced water from nearby oil and gas wells that would represent aqueous phase contaminants. On the basis of quantitative and spatial analysis, we identified that the "thermogenic methane contaminated" groundwater did not have similarities to produced water in terms of ionic character (e.g. Cl/TDS ratio), but rather to the "uncontaminated" groundwater. The analysis indicates that aquifer wells with demonstrated gas phase contamination have not been contacted by an aqueous phase from oil and gas operations according to the methodology we use in this study and the current groundwater quality data from COGCC. However, the research does not prove conclusively that this the case. The results may provide insight on contamination mechanisms since improperly sealed well casing may result in stray gas but not aqueous phase transport. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Numerical Simulation of Multiphase Flow in Nanoporous Organic Matter With Application to Coal and Gas Shale Systems

    NASA Astrophysics Data System (ADS)

    Song, Wenhui; Yao, Jun; Ma, Jingsheng; Sun, Hai; Li, Yang; Yang, Yongfei; Zhang, Lei

    2018-02-01

    Fluid flow in nanoscale organic pores is known to be affected by fluid transport mechanisms and properties within confined pore space. The flow of gas and water shows notably different characteristics compared with conventional continuum modeling approach. A pore network flow model is developed and implemented in this work. A 3-D organic pore network model is constructed from 3-D image that is reconstructed from 2-D shale SEM image of organic-rich sample. The 3-D pore network model is assumed to be gas-wet and to contain initially gas-filled pores only, and the flow model is concerned with drainage process. Gas flow considers a full range of gas transport mechanisms, including viscous flow, Knudsen diffusion, surface diffusion, ad/desorption, and gas PVT and viscosity using a modified van der Waals' EoS and a correlation for natural gas, respectively. The influences of slip length, contact angle, and gas adsorption layer on water flow are considered. Surface tension considers the pore size and temperature effects. Invasion percolation is applied to calculate gas-water relative permeability. The results indicate that the influences of pore pressure and temperature on water phase relative permeabilities are negligible while gas phase relative permeabilities are relatively larger in higher temperatures and lower pore pressures. Gas phase relative permeability increases while water phase relative permeability decreases with the shrinkage of pore size. This can be attributed to the fact that gas adsorption layer decreases the effective flow area of the water phase and surface diffusion capacity for adsorbed gas is enhanced in small pore size.

  1. A fundamental study of gas formation and migration during leakage of stored carbon dioxide in subsurface formations

    NASA Astrophysics Data System (ADS)

    Sakaki, T.; Plampin, M. R.; Lassen, R. N.; Pawar, R. J.; Komatsu, M.; Jensen, K. H.; Illangasekare, T. H.

    2011-12-01

    Geologic sequestration of CO2 has received significant attention as a potential method for reducing the release of greenhouse gases into the atmosphere. Potential risk of leakage of the stored CO2 to the shallow zones of the subsurface is one of the critical issues that is needed to be addressed to design effective field storage systems. If a leak occurs, gaseous CO2 reaching shallow zones of the subsurface can potentially impact the surface and groundwater sources and vegetation. With a goal of developing models that can predict these impacts, a research study is underway to improve our understanding of the fundamental processes of gas-phase formation and multi-phase flow dynamics during CO2 migration in shallow porous media. The approach involves conducting a series of highly controlled experiments in soil columns and tanks to study the effects of soil properties, temperature, pressure gradients and heterogeneities on gas formation and migration. This paper presents the results from a set of column studies. A 3.6m long column was instrumented with 16 soil moisture sensors, 15 of which were capable of measuring electrical conductivity (EC) and temperature, eight water pressure, and two gas pressure sensors. The column was filled with test sands with known hydraulic and retention characteristics with predetermined packing configurations. Deionized water saturated with CO2 under ~0.3 kPa (roughly the same as the hydrostatic pressure at the bottom of the column) was injected at the bottom of the column using a peristaltic pump. Water and gas outflow at the top of the column were monitored continuously. The results, in general, showed that 1) gas phase formation can be triggered by multiple factors such as water pressure drop, temperature rise, and heterogeneity, 2) transition to gas phase tends to occur rather within a short period of time, 3) gas phase fraction was as high as ~40% so that gas flow was not via individual bubble movement but two-phase flow, 4) water outflow that was initially equal to the inflow rate increased when gas-phase started to form (i.e., water gets displaced), and 5) gas starts to flow upward after gas phase fraction stabilizes (i.e., buoyant force overcomes). These results suggest that the generation and migration processes of gas phase CO2 can be modelled as a traditional two-phase flow with source (when CO2 gas exsolved due to complex factors) as well as sink (when gas dissolved) terms. The experimental data will be used to develop and test the conceptual models that will guide the development of numerical simulators for applications involving CO2 storage and leakage.

  2. Direct evidence for the gas phase thermal polymerization of styrene. Determination of the initiation mechanism and structures of the early oligomers by ion mobility.

    PubMed

    Alsharaeh, Edreese H; Ibrahim, Yehia M; El-Shall, M Samy

    2005-05-04

    We present here direct evidence for the thermal self-initiated polymerization of styrene in the gas phase and establish that the initiation process proceeds via essentially the same mechanism (the Mayo mechanism) as in condensed phase polymerization. Furthermore, we provide structural identifications of the dimers and trimers formed in the gas phase.

  3. Impact of Gas-Phase Mechanisms on Weather Research Forecasting Model with Chemistry (WRF/Chem) Predictions: Mechanism Implementation and Comparative Evaluation

    EPA Science Inventory

    Gas-phase mechanisms provide important oxidant and gaseous precursors for secondary aerosol formation. Different gas-phase mechanisms may lead to different predictions of gases, aerosols, and aerosol direct and indirect effects. In this study, WRF/Chem-MADRID simulations are cond...

  4. DEMONSTRATION OF FUEL CELLS TO RECOVER ENERGY FROM LANDFILL GAS: PHASE II. PRETREATMENT SYSTEM PERFORMANCE MEASUREMENT

    EPA Science Inventory

    The report describes Phase II of a demonstration of the utilization of commercial phosphoric acid fuel cells to recover energy from landfill gas. This phase consisted primarily of the construction and testing of a Gas Pretreatment Unit (GPU) whose function is to remove those impu...

  5. The role of gas phase reactions in the deflagration-to-detonation transition of high energy propellants

    NASA Technical Reports Server (NTRS)

    Boggs, T. L.; Price, C. F.; Atwood, A. I.; Zurn, D. E.; Eisel, J. L.; Derr, R. L.

    1980-01-01

    The inadequacies of the two commonly used assumptions are shown, along with the need for considering gas phase reactions. Kinetic parameters that describe the gas phase reactions for several ingredients are provided, and the first steps in convective combustion leading to deflagration to detonation transition are described.

  6. In Situ Environmental TEM in Imaging Gas and Liquid Phase Chemical Reactions for Materials Research.

    PubMed

    Wu, Jianbo; Shan, Hao; Chen, Wenlong; Gu, Xin; Tao, Peng; Song, Chengyi; Shang, Wen; Deng, Tao

    2016-11-01

    Gas and liquid phase chemical reactions cover a broad range of research areas in materials science and engineering, including the synthesis of nanomaterials and application of nanomaterials, for example, in the areas of sensing, energy storage and conversion, catalysis, and bio-related applications. Environmental transmission electron microscopy (ETEM) provides a unique opportunity for monitoring gas and liquid phase reactions because it enables the observation of those reactions at the ultra-high spatial resolution, which is not achievable through other techniques. Here, the fundamental science and technology developments of gas and liquid phase TEM that facilitate the mechanistic study of the gas and liquid phase chemical reactions are discussed. Combined with other characterization tools integrated in TEM, unprecedented material behaviors and reaction mechanisms are observed through the use of the in situ gas and liquid phase TEM. These observations and also the recent applications in this emerging area are described. The current challenges in the imaging process are also discussed, including the imaging speed, imaging resolution, and data management. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. First steps towards a gas-phase acidity ladder for derivatized fullerene dications

    NASA Astrophysics Data System (ADS)

    Petrie, Simon; Javahery, Gholamreza; Bohme, Diethard K.

    1993-03-01

    C2+60 can be derivatized by gas-phase ion/molecule reactions with polar hydrogen-bearing molecules. The adduct dications so produced may then undergo proton transfer to neutrals. The occurrence or absence of proton transfer as a secondary process gives information on the gas-phase acidity of the dicationic species C60·(XH)2+in. We have performed studies using a selected-ion flow tube at 294 ± 2 K and 0.35 ± 0.01 Torr, and have used observed reactivity of such dicationic fullerene adducts to determine upper or lower limits to their apparent and absolute gas-phase acidities. We present also a rationale for assessing the proton-transfer reactivity of dications via the apparent gas-phase acidity of these species, rather than the traditional use of gas-phase basicities or proton affinities. We propose that further studies of proton transfer from polycharged fullerene adducts may provide considerable useful information to model the reactivity of polyprotonated proteins and other large molecular polycatiions which can now be produced by techniques such as electrospray ionization.

  8. Dark current reduction of Ge photodetector by GeO₂ surface passivation and gas-phase doping.

    PubMed

    Takenaka, Mitsuru; Morii, Kiyohito; Sugiyama, Masakazu; Nakano, Yoshiaki; Takagi, Shinichi

    2012-04-09

    We have investigated the dark current of a germanium (Ge) photodetector (PD) with a GeO₂ surface passivation layer and a gas-phase-doped n+/p junction. The gas-phase-doped PN diodes exhibited a dark current of approximately two orders of magnitude lower than that of the diodes formed by a conventional ion implantation process, indicating that gas-phase doping is suitable for low-damage PN junction formation. The bulk leakage (Jbulk) and surface leakage (Jsurf) components of the dark current were also investigated. We have found that GeO₂ surface passivation can effectively suppress the dark current of a Ge PD in conjunction with gas-phase doping, and we have obtained extremely low values of Jbulk of 0.032 mA/cm² and Jsurf of 0.27 μA/cm.

  9. Investigations on the self-excited oscillations in a kerosene spray flame

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de la Cruz Garcia, M.; Mastorakos, E.; Dowling, A.P.

    2009-02-15

    A laboratory scale gas turbine type burner at atmospheric pressure and with air preheat was operated with aviation kerosene Jet-A1 injected from a pressure atomiser. Self-excited oscillations were observed and analysed to understand better the relationship between the spray and thermo-acoustic oscillations. The fluctuations of CH{sup *} chemiluminescence measured simultaneously with the pressure were used to determine the flame transfer function. The Mie scattering technique was used to record spray fluctuations in reacting conditions with a high speed camera. Integrating the Mie intensity over the imaged region gave a temporal signal acquired simultaneously with pressure fluctuations and the transfer functionmore » between the light scattered from the spray and the velocity fluctuations in the plenum was evaluated. Phase Doppler anemometry was used for axial velocity and drop size measurements at different positions downstream the injection plane and for various operating conditions. Pressure spectra showed peaks at a frequency that changed with air mass flow rate. The peak for low air mass flow rate operation was at 220 Hz and was associated with a resonance of the supply plenum. At the same global equivalence ratio but at high air mass flow rates, the pressure spectrum peak was at 323 Hz, a combustion chamber resonant frequency. At low air flow rates, the spray fluctuation motion was pronounced and followed the frequency of the pressure oscillation. At high air flow rates, more effective evaporation resulted in a complete disappearance of droplets at an axial distance of about 1/3 burner diameters from the injection plane, leading to a different flame transfer function and frequency of the self-excited oscillation. The results highlight the sensitivity of the self-excited oscillation to the degree of mixing achieved before the main recirculation zone. (author)« less

  10. Effects of Fresh and Aged Vehicular Exhaust Emissions on Breathing Pattern and Cellular Responses – Pilot Single Vehicle Study

    PubMed Central

    Diaz, Edgar A.; Chung, Yeonseung; Papapostolou, Vasileios; Lawrence, Joy; Long, Mark S.; Hatakeyama, Vivian; Gomes, Brenno; Calil, Yasser; Sato, Rodrigo; Koutrakis, Petros; Godleski, John J.

    2013-01-01

    The study presented here is a laboratory pilot study using diluted car exhaust from a single vehicle to assess differences in toxicological response between primary emissions and secondary products resulting from atmospheric photochemical reactions of gas phase compounds with O3, OH and other radicals. Sprague-Dawley rats were exposed for five hours to either filtered room air (Sham) or one of two different atmospheres: 1. Diluted Car Exhaust (P) + Mt. Saint Helens Ash (MSHA); 2. P+MSHA+SOA (Secondary Organic Aerosol, formed during simulated photochemical aging of diluted exhaust). Primary and secondary gases were removed using a non-selective diffusion denuder. Continuous respiratory data was collected during the exposure, and broncho-alveolar lavage (BAL) and complete blood counts (CBC) were performed 24 hours after exposure. ANOVA models were used to assess the exposure effect and to compare those effects across different exposure types. Total average exposures were 363±66 μg/m3 P+MSHA and 212±95 μg/m3 P+MSHA+SOA. For both exposures, we observed decreases in breathing rate, tidal and minute volumes (TV, MV) and peak and median flows (PIF, PEF and EF50) along with increases in breathing cycle times (Ti, Te) compared to sham. These results indicate that the animals are changing their breathing pattern with these test atmospheres. Exposure to P+MSHA+SOA produced significant increases in Total Cells, Macrophages and Neutrophils in the BAL and in-vivo chemiluminescence of the lung. There were no significant differences in CBC parameters. Our data suggest that simulated atmospheric photochemistry, producing SOA in the P+MSHA+SOA exposures, enhanced the toxicity of vehicular emissions. PMID:22486346

  11. Effects of fresh and aged vehicular exhaust emissions on breathing pattern and cellular responses--pilot single vehicle study.

    PubMed

    Diaz, Edgar A; Chung, Yeonseung; Papapostolou, Vasileios; Lawrence, Joy; Long, Mark S; Hatakeyama, Vivian; Gomes, Brenno; Calil, Yasser; Sato, Rodrigo; Koutrakis, Petros; Godleski, John J

    2012-04-01

    The study presented here is a laboratory pilot study using diluted car exhaust from a single vehicle to assess differences in toxicological response between primary emissions and secondary products resulting from atmospheric photochemical reactions of gas phase compounds with O₃, OH and other radicals. Sprague Dawley rats were exposed for 5 h to either filtered room air (sham) or one of two different atmospheres: (i) diluted car exhaust (P)+Mt. Saint Helens Ash (MSHA); (ii) P+MSHA+secondary organic aerosol (SOA, formed during simulated photochemical aging of diluted exhaust). Primary and secondary gases were removed using a nonselective diffusion denuder. Continuous respiratory data was collected during the exposure, and bronchoalveolar lavage (BAL) and complete blood counts (CBC) were performed 24 h after exposure. ANOVA models were used to assess the exposure effect and to compare those effects across different exposure types. Total average exposures were 363 ± 66 μg/m³ P+MSHA and 212 ± 95 µg/m³ P+MSHA+SOA. For both exposures, we observed decreases in breathing rate, tidal and minute volumes (TV, MV) and peak and median flows (PIF, PEF and EF50) along with increases in breathing cycle times (Ti, Te) compared to sham. These results indicate that the animals are changing their breathing pattern with these test atmospheres. Exposure to P+MSHA+SOA produced significant increases in total cells, macrophages and neutrophils in the BAL and in vivo chemiluminescence of the lung. There were no significant differences in CBC parameters. Our data suggest that simulated atmospheric photochemistry, producing SOA in the P+MSHA+SOA exposures, enhanced the toxicity of vehicular emissions.

  12. Thromboresistance Characterization of Extruded Nitric Oxide-Releasing Silicone Catheters

    PubMed Central

    Amoako, Kagya A.; Archangeli, Christopher; Handa, Hitesh; Major, Terry; Meyerhoff, Mark E.; Annich, Gail M.; Bartlett, Robert H.

    2013-01-01

    Intravascular catheters used in clinical practice can activate platelets, leading to thrombus formation and stagnation of blood flow. Nitric oxide (NO)-releasing polymers have been shown previously to reduce clot formation on a number of blood contacting devices. In this work, trilaminar NO-releasing silicone catheters were fabricated and tested for their thrombogenicity. All catheters had specifications of L = 6 cm, inner diameter = 21 gauge (0.0723 cm), outer diameter = 12 gauge (0.2052 cm), and NO-releasing layer thickness = 200 ± 11 μm. Control and NO-releasing catheters were characterized in vitro for their NO flux and NO release duration by gas phase chemiluminescence measurements. The catheters were then implanted in the right and left internal jugular veins of (N = 6 and average weight = 3 kg) adult male rabbits for 4 hours thrombogenicity testing. Platelet counts and function, methemoglobin (metHb), hemoglobin (Hb), and white cell counts and functional time (defined as patency time of catheter) were monitored as measured outcomes. Nitric oxide-releasing catheters (N = 6) maintained an average flux above (2 ± 0.5) × 10−10 mol/min/cm2 for more than 24 hours, whereas controls showed no NO release. Methemoglobin, Hb, white cell, and platelet counts and platelet function at 4 hours were not significantly different from baseline (α = 0.05). However, clots on controls were visibly larger and prevented blood draws at a significantly (p < 0.05) earlier time (2.3 ± 0.7 hours) into the experiment, whereas all NO-releasing catheters survived the entire 4 hours test period. Results indicate that catheter NO flux levels attenuated thrombus formation in a short-term animal model. PMID:22395119

  13. Monitoring gas-phase CO2 in the headspace of champagne glasses through combined diode laser spectrometry and micro-gas chromatography analysis.

    PubMed

    Moriaux, Anne-Laure; Vallon, Raphaël; Parvitte, Bertrand; Zeninari, Virginie; Liger-Belair, Gérard; Cilindre, Clara

    2018-10-30

    During Champagne or sparkling wine tasting, gas-phase CO 2 and volatile organic compounds invade the headspace above glasses, thus progressively modifying the chemical space perceived by the consumer. Gas-phase CO 2 in excess can even cause a very unpleasant tingling sensation perturbing both ortho- and retronasal olfactory perception. Monitoring as accurately as possible the level of gas-phase CO 2 above glasses is therefore a challenge of importance aimed at better understanding the close relationship between the release of CO 2 and a collection of various tasting parameters. Here, the concentration of CO 2 found in the headspace of champagne glasses served under multivariate conditions was accurately monitored, all along the 10 min following pouring, through a new combined approach by a CO 2 -Diode Laser Sensor and micro-gas chromatography. Our results show the strong impact of various tasting conditions (volume dispensed, intensity of effervescence, and glass shape) on the release of gas-phase CO 2 above the champagne surface. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Two-phase turbine engines. [using gas-liquid mixture accelerated in nozzles

    NASA Technical Reports Server (NTRS)

    Elliott, D. G.; Hays, L. G.

    1976-01-01

    A description is given of a two-phase turbine which utilizes a uniform mixture of gas and liquid accelerated in nozzles of the types reported by Elliott and Weinberg (1968). The mixture acts directly on an axial flow or tangential impulse turbine or is separated into gas and liquid streams which operate separately on a gas turbine and a hydraulic turbine. The basic two-phase cycles are examined, taking into account working fluids, aspects of nozzle expansion, details of turbine cycle operation, and the effect of mixture ratio variation. Attention is also given to two-phase nozzle efficiency, two-phase turbine operating characteristics and efficiencies, separator turbines, and impulse turbine experiments.

  15. Simulation Approach for Microscale Noncontinuum Gas-Phase Heat Transfer

    NASA Astrophysics Data System (ADS)

    Torczynski, J. R.; Gallis, M. A.

    2008-11-01

    In microscale thermal actuators, gas-phase heat transfer from the heated beams to the adjacent unheated substrate is often the main energy-loss mechanism. Since the beam-substrate gap is comparable to the molecular mean free path, noncontinuum gas effects are important. A simulation approach is presented in which gas-phase heat transfer is described by Fourier's law in the bulk gas and by a wall boundary condition that equates the normal heat flux to the product of the gas-solid temperature difference and a heat transfer coefficient. The dimensionless parameters in this heat transfer coefficient are determined by comparison to Direct Simulation Monte Carlo (DSMC) results for heat transfer from beams of rectangular cross section to the substrate at free-molecular to near-continuum gas pressures. This simulation approach produces reasonably accurate gas-phase heat-transfer results for wide ranges of beam geometries and gas pressures. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  16. Interaction between phases in the liquid–gas system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berry, R. S., E-mail: bmsmirnov@gmail.com; Smirnov, B. M.

    This work analyzes the equilibrium between a liquid and a gas over this liquid separated by an interface. Various gas forms exist inside the liquid: dissolved gas molecules attached to solvent molecules, free gas molecules, and gaseous bubbles. Thermodynamic equilibrium is maintained between two phases; the first phase is the liquid containing dissolved and free molecules, and the second phase is the gas over the liquid and bubbles inside it. Kinetics of gas transition between the internal and external gas proceeds through bubbles and includes the processes of bubbles floating up and bubble growth as a result of association duemore » to the Smoluchowski mechanism. Evolution of a gas in the liquid is considered using the example of oxygen in water, and numerical parameters of this system are given. In the regime under consideration for an oxygen–water system, transport of oxygen into the surrounding air proceeds through micron-size bubbles with lifetimes of hours. This regime is realized if the total number of oxygen molecules in water is small compared with the numbers of solvated and free molecules in the liquid.« less

  17. The solubility of gallium oxide in vapor and two-phase fluid filtration in hydrothermal systems

    NASA Astrophysics Data System (ADS)

    Bychkov, Andrew; Matveeva, Svetlana; Nekrasov, Stanislav

    2010-05-01

    The solubility of gallium and aluminum oxides in gas phase in the system Ga2O3 (Al2O3)-HCl-H2O was studied at 150-350°C and pressure up to saturated vapor. The concentration of gallium increases with the increasing of HCl pressure. The formulae of gallium gaseous specie was determined as GaOHCl2. The constant of gallium oxide solubility reaction was calculated at 150, 200, 250, 300 and 350°C. The concentration of aluminum in gas phase is insignificant in the same conditions. The possibility of gallium transportation in gas phase with small quantity of Al allow to divide this elements in hydrothermal processes with gas phase. The Ga/Al ratio in muscovite can be used as the indicator of gas phase separation and condensation. This indicator was not considered in the geochemical literature earlier. The separation of gas and liquid phases was determined in Akchatau (Kazahstan) and Spokoinoe (Russia) greisen W deposit by carbon isotope fractionation of carbon dioxide in fluid inclusion. The important feature of both ore mains is heterogenization and boiling of ore-forming fluids. Greisen ore bodies are formed as a result of strongly focused solution flow in the T-P gradient fields. It is possible to divide ore bodies of Akchatau in two types: muscovite and quartz. Muscovite type veins are thin and have small metasyntactic zone. Quartz type veins are localized in fault with large vertical extent (500 m) and content the large quantity of wolframite. These veins formed in condition of significant pressure decreasing from 2.5 to 0.5 kbar with fluid boiling. Gas and liquid phase separation specifies the vertical zonality of quartz type veins. The gas phase with the high gallium concentration is separated from a flow of liquid phase. Liquid phase react with the granites forming greisen metasomatites. Condensation of the gas phase in upper parts of massive produces the increasing of Ga/Al ratio in muscovite 3-5 times more, then in granites and bottom part of vein (from 2×10-4 to 8×10-4 mass ratio). The muscovite type veins has no separation between gas and liquid due to there thickness and small pressure gradient. There is no difference in Ga/Al ratio in muscovite from this veins. The Spokoinoe deposit is classified by mineralized dome type. The heterogenization of fluid occurs in H2O-CO2 system for water phase and carbon dioxide with temperature decreasing. Two-phase flow is separated in granite, forming greisen metosomatites. The Ga/Al ratio in rock increase up to 3 times to the upper part of metasomatitic zone. The Ga/Al ratio in muscovite can be applied for other hydrothermal systems for geochemical indicator of gas phase separation and condensation zone determination. This work is supported by RFBR project 10-05-00670 and 10-05-00320.

  18. Calculation of the Rate of Combustion of a Metallized Composite Solid Propellant with Allowance for the Size Distribution of Agglomerates

    NASA Astrophysics Data System (ADS)

    Poryazov, V. A.; Krainov, A. Yu.

    2016-05-01

    A physicomathematical model of combustion of a metallized composite solid propellant based on ammonium perchlorate has been presented. The model takes account of the thermal effect of decomposition of a condensed phase (c phase), convection, diffusion, the exothermal chemical reaction in a gas phase, the heating and combustion of aluminum particles in the gas flow, and the velocity lag of the particles behind the gas. The influence of the granulometric composition of aluminum particles escaping from the combustion surface on the linear rate of combustion has been investigated. It has been shown that information not only on the kinetics of chemical reactions in the gas phase, but also on the granulometric composition of aluminum particles escaping from the surface of the c phase into the gas, is of importance for determination of the linear rate of combustion.

  19. A Computer Model for Analyzing Volatile Removal Assembly

    NASA Technical Reports Server (NTRS)

    Guo, Boyun

    2010-01-01

    A computer model simulates reactional gas/liquid two-phase flow processes in porous media. A typical process is the oxygen/wastewater flow in the Volatile Removal Assembly (VRA) in the Closed Environment Life Support System (CELSS) installed in the International Space Station (ISS). The volatile organics in the wastewater are combusted by oxygen gas to form clean water and carbon dioxide, which is solved in the water phase. The model predicts the oxygen gas concentration profile in the reactor, which is an indicator of reactor performance. In this innovation, a mathematical model is included in the computer model for calculating the mass transfer from the gas phase to the liquid phase. The amount of mass transfer depends on several factors, including gas-phase concentration, distribution, and reaction rate. For a given reactor dimension, these factors depend on pressure and temperature in the reactor and composition and flow rate of the influent.

  20. Exploring the relevance of gas-phase structures to biology: cold ion spectroscopy of the decapeptide neurokinin A.

    PubMed

    Pereverzev, A Y; Boyarkin, O V

    2017-02-01

    Linking the intrinsic tertiary structures of biomolecules to their native geometries is a central prerequisite for making gas-phase studies directly relevant to biology. The isolation of molecules in the gas phase eliminates hydrophilic interactions with solvents, to some extent mimicking a hydrophobic environment. Intrinsic structures therefore may resemble native ones for peptides that in vivo reside in a hydrophobic environment (e.g., binding pockets of receptors). In this study, we investigate doubly protonated neurokinin A (NKA) using IR-UV double resonance cold ion spectroscopy and find only five conformers of this decapeptide in the gas phase. In contrast, NMR data show that in aqueous solutions, NKA exhibits high conformational heterogeneity, which reduces to a few well-defined structures in hydrophobic micelles. Do the gas-phase structures of NKA resemble these native structures? The IR spectra reported here allow the validation of future structural calculations that may answer this question.

Top