Homographic Patch Feature Transform: A Robustness Registration for Gastroscopic Surgery.
Hu, Weiling; Zhang, Xu; Wang, Bin; Liu, Jiquan; Duan, Huilong; Dai, Ning; Si, Jianmin
2016-01-01
Image registration is a key component of computer assistance in image guided surgery, and it is a challenging topic in endoscopic environments. In this study, we present a method for image registration named Homographic Patch Feature Transform (HPFT) to match gastroscopic images. HPFT can be used for tracking lesions and augmenting reality applications during gastroscopy. Furthermore, an overall evaluation scheme is proposed to validate the precision, robustness and uniformity of the registration results, which provides a standard for rejection of false matching pairs from corresponding results. Finally, HPFT is applied for processing in vivo gastroscopic data. The experimental results show that HPFT has stable performance in gastroscopic applications.
Wang, Caixia; Chen, Yuanyuan; Yang, Feng; Ren, Jie; Yu, Xin; Wang, Jiani; Sun, Siyu
2016-08-01
The present study aimed to assess the efficacy of computer-based endoscope cleaning and disinfection using a hospital management information system (HMIS). A total of 2,674 gastroscopes were eligible for inclusion in this study. For the processes of disinfection management, the gastroscopes were randomly divided into 2 groups: gastroscope disinfection HMIS (GD-HMIS) group and manual group. In the GD-HMIS group, an integrated circuit card (IC card) chip was installed to monitor and record endoscope cleaning and disinfection automatically and in real time, whereas the endoscope cleaning and disinfection in the manual group was recorded manually. The overall disinfection progresses for both groups were recorded, and the total operational time was calculated. For the GD-HMIS group, endoscope disinfection HMIS software was successfully developed. The time to complete a single session of cleaning and disinfecting on a gastroscope was 15.6 minutes (range, 14.3-17.2 minutes) for the GD-HMIS group and 21.3 minutes (range, 20.2-23.9 minutes) for the manual group. Failure to record information, such as the identification number of the endoscope, occasionally occurred in the manual group, which affected the accuracy and reliability of manual recording. Computer-based gastroscope cleaning and disinfection using a hospital management information system could monitor the process of gastroscope cleaning and disinfection in real time and improve the accuracy and reliability, thereby ensuring the quality of gastroscope cleaning and disinfection. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Schmitt, Cristiane; Pires Maciel, Amanda Luiz; Boszczowski, Icaro; da Silva, Thaís Pereira; Neves, Eliane Aparecida Job; Rossini, Giulio Fabio; Rizek, Camila; Costa, Silvia Figueiredo; Lourenço, Rogério Ferreira; Alfa, Michelle J
2018-05-18
Using adenosine triphosphate (ATP) tests to assess manual cleaning of gastroscopes and to determine the associated workload in a busy endoscopy unit. Patient-used gastroscopes were sampled before and after cleaning to assess ATP levels, bioburden, and protein. Samples were collected by flushing 20 mL of sterile water through the biopsy port to the distal end. Time spent for reprocessing and performing the ATP test was recorded. Twenty-four samples were collected from 10 gastroscopes. After manual cleaning, 14/24 (58.3%) samples had no microbial growth (mean, 21 colony-forming units/cm 2 ), and in 22/24 (91.7%) samples the protein was undetectable (mean, 0.04 µg/cm 2 ). ATP test was above the cutoff (200 relative light units [RLU]) in 17/24 (70.8%) samples (mean, 498 RLU). After the second cleaning, 11/17 (64.7%) gastroscopes still failed the ATP test (mean, 321.2 RLU). The mean time spent to perform manual cleaning and ATP tests was 16 and 8 minutes, respectively. Hence, each test increased the length of time for cleaning plus testing cleanliness by 50%. Further studies regarding the optimal cutoff for ATP tests are needed. ATP tests for cleaning monitoring are easy to perform and provide immediate feedback to the team. However, the increased workload needs to be considered. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Swab culture monitoring of automated endoscope reprocessors after high-level disinfection
Lu, Lung-Sheng; Wu, Keng-Liang; Chiu, Yi-Chun; Lin, Ming-Tzung; Hu, Tsung-Hui; Chiu, King-Wah
2012-01-01
AIM: To conduct a bacterial culture study for monitoring decontamination of automated endoscope reprocessors (AERs) after high-level disinfection (HLD). METHODS: From February 2006 to January 2011, authors conducted randomized consecutive sampling each month for 7 AERs. Authors collected a total of 420 swab cultures, including 300 cultures from 5 gastroscope AERs, and 120 cultures from 2 colonoscope AERs. Swab cultures were obtained from the residual water from the AERs after a full reprocessing cycle. Samples were cultured to test for aerobic bacteria, anaerobic bacteria, and mycobacterium tuberculosis. RESULTS: The positive culture rate of the AERs was 2.0% (6/300) for gastroscope AERs and 0.8% (1/120) for colonoscope AERs. All the positive cultures, including 6 from gastroscope and 1 from colonoscope AERs, showed monofloral colonization. Of the gastroscope AER samples, 50% (3/6) were colonized by aerobic bacterial and 50% (3/6) by fungal contaminations. CONCLUSION: A full reprocessing cycle of an AER with HLD is adequate for disinfection of the machine. Swab culture is a useful method for monitoring AER decontamination after each reprocessing cycle. Fungal contamination of AERs after reprocessing should also be kept in mind. PMID:22529696
Scalable gastroscopic video summarization via similar-inhibition dictionary selection.
Wang, Shuai; Cong, Yang; Cao, Jun; Yang, Yunsheng; Tang, Yandong; Zhao, Huaici; Yu, Haibin
2016-01-01
This paper aims at developing an automated gastroscopic video summarization algorithm to assist clinicians to more effectively go through the abnormal contents of the video. To select the most representative frames from the original video sequence, we formulate the problem of gastroscopic video summarization as a dictionary selection issue. Different from the traditional dictionary selection methods, which take into account only the number and reconstruction ability of selected key frames, our model introduces the similar-inhibition constraint to reinforce the diversity of selected key frames. We calculate the attention cost by merging both gaze and content change into a prior cue to help select the frames with more high-level semantic information. Moreover, we adopt an image quality evaluation process to eliminate the interference of the poor quality images and a segmentation process to reduce the computational complexity. For experiments, we build a new gastroscopic video dataset captured from 30 volunteers with more than 400k images and compare our method with the state-of-the-arts using the content consistency, index consistency and content-index consistency with the ground truth. Compared with all competitors, our method obtains the best results in 23 of 30 videos evaluated based on content consistency, 24 of 30 videos evaluated based on index consistency and all videos evaluated based on content-index consistency. For gastroscopic video summarization, we propose an automated annotation method via similar-inhibition dictionary selection. Our model can achieve better performance compared with other state-of-the-art models and supplies more suitable key frames for diagnosis. The developed algorithm can be automatically adapted to various real applications, such as the training of young clinicians, computer-aided diagnosis or medical report generation. Copyright © 2015 Elsevier B.V. All rights reserved.
Feng, X; Huang, Z C; Tao, F; Ou, X L
2016-02-01
To investigate clinical aspects and a new operative method for resecting third branchial fistula. The clinical aspects of 4 patients with third branchial fistula were retrospectively analyzed. It is difficult to locate the inner orifice of fistula through neck path due to tiny diameter of inner orifice. The inner orifice could be found and closed effectively by inserting yellow zebra guidewire from sinus piriformis with gastroscope. The mucous membrane of sinus piriformis could not be damaged due to the soft pointed end of yellow zebra guidewire. 4 cases were treated successfully without pharyngeal fistula or recurrent laryngeal nerve injury. No recurrent infections were found in all cases with follows-up of 6-66 months. Ineffectiveness of radiography with meglumine diatrizoate or oral administration of methylene blue before operation indicates tiny fistula. In this case, resection of third branchial fistula with the assistance of gastroscope and yellow zebra guidewire under general anesthesia can be performed. This innovative method of diagnosis and treatment is worth of application clinically.
Li, Yanmin; Liu, Hao; Hao, Siwen; Li, Hongyi; Han, Jianda; Yang, Yunsheng
2017-03-01
Robot-assisted manipulation is promising for solving problems such as understaffing and the risk of infection in gastro-intestinal endoscopy. However, the commonly used friction rollers in few existing systems have a potential risk of deforming flexible endoscopes for non-uniform clamping. This paper presents a robotic system for a standard flexible endoscope and focuses on a novel gastroscope intervention mechanism (GIM), which provides circumferentially uniform clamping with an airbag. The GIM works with a relay-on mechanism in a way similar to manual operation. The shear stiffness of airbag and the critical slipping force (CSF) were analysed to determine the parameters of the airbag. A fuzzy PID controller was employed to realize a fast response and high accuracy of pneumatic actuation. Experiments were performed to evaluate the accuracy, stiffness and CSF. In vitro and in vivo animal experiments were also carried out. The GIM realized an accuracy of 0.025 ± 0.2 mm and -0.03 ± 0.25° for push-pull and rotation without delivery resistance. Under < 10 N delivery resistance, the error caused by the airbag stiffness was < 0.24 mm. A quadratic polynomial could be used to describe the relationship between the CSF and pneumatic pressure. The novel GIM could effectively deliver gastroscopes. The pneumatic-driven clamping method proposed could protect the gastroscope by circumferentially uniform clamping force and the CSF could be properly controlled to guarantee operating safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Use of fibre-optic endoscopes in studies of gastric digestion in carnivorous vertebrates.
Jackson, S; Cooper, J
1988-01-01
1. Two methods of assessing gastric digestion rates of three prey types fed to Sooty albatrosses Phoebetria fusca were compared: removal of stomach contents, using a water-flushing stomach pump (a technique used commonly in diet studies), and inspection using a fibre-optic gastroscope (a previously unused technique). 2. The stomach pump yielded quantitative information, but proved stressful and resulted in incomplete recovery of meals ingested 3-6 hr before pumping. Gastric morphology of the animals studied and digestion state of their stomach contents may influence the effectiveness of this technique. 3. Inspection using the gastroscope yielded qualitative information only but permitted serial inspection of the same animal, and was less stressful than the stomach pump. Times for total evacuation of the stomach were 6-12 hr less when estimated using the gastroscope than when using the stomach pump. 4. The specifications of endoscopes relevant to their use by biologists are given. 5. Previous non-medical biological uses of endoscopes are given. Potential uses include underwater observations, sampling of digestive juices and stomach linings for enzyme analyses, observations of ingested prey, and assessment of parasite infestation.
Image enhancement based on in vivo hyperspectral gastroscopic images: a case study
NASA Astrophysics Data System (ADS)
Gu, Xiaozhou; Han, Zhimin; Yao, Liqing; Zhong, Yunshi; Shi, Qiang; Fu, Ye; Liu, Changsheng; Wang, Xiguang; Xie, Tianyu
2016-10-01
Hyperspectral imaging (HSI) has been recognized as a powerful tool for noninvasive disease detection in the gastrointestinal field. However, most of the studies on HSI in this field have involved ex vivo biopsies or resected tissues. We proposed an image enhancement method based on in vivo hyperspectral gastroscopic images. First, we developed a flexible gastroscopy system capable of obtaining in vivo hyperspectral images of different types of stomach disease mucosa. Then, depending on a specific object, an appropriate band selection algorithm based on dependence of information was employed to determine a subset of spectral bands that would yield useful spatial information. Finally, these bands were assigned to be the color components of an enhanced image of the object. A gastric ulcer case study demonstrated that our method yields higher color tone contrast, which enhanced the displays of the gastric ulcer regions, and that it will be valuable in clinical applications.
Evaluation of the tip-bending response in clinically used endoscopes.
Rozeboom, Esther D; Reilink, Rob; Schwartz, Matthijs P; Fockens, Paul; Broeders, Ivo A M J
2016-04-01
Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses.
Vaden, S L; Hammerberg, B; Davenport, D J; Orton, S M; Trogdon, M M; Melgarejo, L T; VanCamp, S D; Williams, D A
2000-01-01
The purpose of this study was to evaluate Soft Coated Wheaten Terriers (SCWTs) affected with protein-losing enteropathy (PLE) or protein-losing nephropathy (PLN) or both for allergy to food. We performed gastroscopic food-sensitivity testing, a provocative dietary trial, and measurement of fecal immunoglobulin E (IgE) in 6 SCWTs affected with PLE or PLN or both. Positive gastroscopic food-sensitivity test reactions were noted in 5 of 6 dogs. Positive reactions were found to milk in 4 dogs, to lamb in 2 dogs, and to wheat and chicken each in 1 dog. Adverse reactions to food (diarrhea, vomiting, or pruritus) were detected in all 6 dogs during the provocative dietary trial. Adverse reactions were found to corn in 5 dogs, to tofu in 3 dogs, to cottage cheese in 2 dogs, to milk in 2 dogs, to farina cream of wheat in 2 dogs, and to lamb in 2 dogs. Serum albumin concentrations significantly decreased and fecal alpha1-protease inhibitor concentration significantly increased 4 days after the provocative trial when compared with baseline values. Antigen-specific fecal IgE varied throughout the provocative trial, with peak levels following ingestion of test meals. We conclude that food hypersensitivities are present in SCWTs affected with the syndrome of PLE/PLN. Mild inflammatory bowel disease was already established in the 6 SCWTs of this report at the time of study, making it impossible to determine if food allergies were the cause or result of the enteric disease.
Evaluation of the tip-bending response in clinically used endoscopes
Rozeboom, Esther D.; Reilink, Rob; Schwartz, Matthijs P.; Fockens, Paul; Broeders, Ivo A. M. J.
2016-01-01
Background and study aims: Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. Materials and methods: We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. Results: Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. Conclusion: This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses. PMID:27092330
Kim, Min-Kyoon; Park, Joong-Min; Choi, Yoo-Shin; Chi, Kyong-Choun
2012-04-01
Billroth I gastroduodenostomy using a circular stapler is the most preferred reconstruction method after laparoscopy-assisted distal gastrectomy (LADG). The optimal stapler size for this procedure has not yet been proposed. Sixty-five patients who underwent LADG and stapled anastomosis with a 25-mm stapler (25-mm group) and a 29-mm stapler (29-mm group) were enrolled in this study. Clinical data and gastroscopic findings at 6 and 12 months after surgery were retrospectively reviewed. Postoperative complications and postprandial symptoms were similar in both groups. Gastroscopically, food materials remained more frequently in the remnant stomach in the 25-mm group than in the 29-mm group at 6 months after surgery (P=.041). Gastritis and bile reflux were observed more frequently in the 29-mm group than in the 25-mm group (P=.012 and P=.015, respectively). All these differences in the gastroscopic findings between the two groups decreased at 12 months after surgery except for reflux esophagitis, which was observed more frequently in the 29-mm group (P=.002). The length of the incision was smaller in the 25-mm group than in the 29-mm group (4.39 cm versus 4.95 cm, P=.009). A small-diameter stapler is a risk factor for gastric stasis in the early postoperative period, whereas a large-diameter stapler is a risk factor for gastritis and bile reflux in the early postoperative period and for esophagitis in the late postoperative period. Thus, a small-diameter circular stapler has more advantages over a large-diameter circular stapler. It also enables a reliable anastomosis through a smaller incision and easy handling of the stapler during anastomosis.
2012-01-01
Background The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. Methods We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. Results The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). Conclusions Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not. PMID:22943739
Chiu, King-Wah; Tsai, Ming-Chao; Wu, Keng-Liang; Chiu, Yi-Chun; Lin, Ming-Tzung; Hu, Tsung-Hui
2012-09-03
The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not.
Fluoroscopy-Guided Pull-Through Gastrostomy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitton, M. B., E-mail: pitton@radiologie.klinik.uni-mainz.de; Herber, S.; Dueber, C.
2008-01-15
The purpose of this study was to simplify a fluoroscopy guided gastrostomy technique using pull-type tubes which are traditionally introduced with gastroscopic assistance. The stomach was transorally probed with a 5-Fr catheter and a guidewire. A second access was performed percutaneously through the anterior abdominal and gastric wall using an 8-Fr sheath and an 8-Fr guiding catheter. A duplicated guidewire was introduced through the guiding catheter in order to result in a great custom-made loop within the stomach. The transoral guidewire was captured and tightened with this loop and the guiding catheter, and both were subsequently pulled by the transoralmore » guidewire until the tip of the guiding catheter exited the mouth. A thread was fed through the guiding catheter for fixation of the pull-type gastrostomy tube. Finally, the fixed tube was pulled through the esophagus into the stomach and through the abdominal wall until the anterior gastric wall fixed the retention plate of the tube. Thirty-seven patients (28 male, 9 female; age, 65.1 {+-} 14.4 years) with miscellaneous indications for percutaneous gastrostomies were supplied with pull-type gastrostomy catheters in a fluoroscopy technique without endoscopic assistance. Twenty-five of the 37 patients (67.6%) had undergone unsuccessful preceding gastroscopically guided PEG attempts because of tumor stenosis (n = 12) or impossible transillumination of the abdominal wall (n = 13). All procedures were technically successful, without major complications. Particularly, all patients with frustrating gastroscopic attempts were successfully provided with pull-type gastrostomy tubes. Five minor complications occurred: one tube loss during the passage of the hypopoharynx because of a torn thread, one transient small leakage alongside the tube (both successfully treated), and three cases of transient moderate local pain without leakage (symptomatic treatment). We conclude that this fluoroscopy-guided pull-through gastrostomy technique is easy and safe to perform and may be suggested as a standard procedure for radiological gastrostomies. It combines the ease of the radiological approach with the advantages of the pull-type tube devices, particularly the benefits of the typical retention plates.« less
NASA Astrophysics Data System (ADS)
Terry, Neil G.; Zhu, Yizheng; Brown, William J.; Wax, Adam
2008-02-01
Improved methods for detecting dysplasia, or pre-cancerous growth are a current clinical need, particularly in the esophagus. The currently accepted method of random biopsy and histological analysis provides only a limited examination of tissue in question while being coupled with a long time delay for diagnosis. Optical scattering spectroscopy, in contrast, allows for inspection of the cellular structure and organization of tissue in vivo. Fourierdomain angle-resolved low-coherence interferometry (a/LCI) is a novel scattering spectroscopy technique that provides quantitative depth-resolved morphological measurements of the size and optical density of the examined cell nuclei, which are characteristic biomarkers of dysplasia. Previously, the clinical viability of the a/LCI system was demonstrated by analysis of ex vivo human esophageal tissue in Barrett's esophagus patients using a portable a/LCI system. We present an adaptation of the portable a/LCI instrument that can be used in the accessory channel of a gastroscope, allowing for in vivo measurements to be taken. Modifications to the previous generation system include the use of an improved imaging spectrometer allowing for subsecond acquisition times and the redesign of the delivery fiber and imaging optics in order to fit in the accessory channel of a gastroscope. Accurate sizing of polystyrene microspheres and other preliminary results are presented, demonstrating promise as a clinically viable tool.
Assouad, Jalal; Masmoudi, Hicham; Gonzalez-Bermejo, Jesus; Morélot-Panzini, Capucine; Diop, Moustapha; Grunenwald, Dominique; Similowski, Thomas
2012-08-01
Phrenic nerve stimulation for diaphragm pacing allows patients with central respiratory paralysis to be weaned from mechanical ventilation. Two procedures are available, either intrathoracic (bilateral thoracotomy) or intradiaphragmatic (four ports laparoscopy). The present experimental work assesses the feasibility, safety and efficacy of a trans-mediastinal implantation of intradiaphragmatic phenic nerve stimulation electrodes using a flexible gastroscope through a cervical incision. We operated on nine ewes. After selective bronchial intubation, we dissected the latero-tracheal space and opened both mediastinal pleura. We then introduced a flexible gastroscope into the pleural cavities, in a sequential manner. The phrenic nerves were located and followed up to the diaphragm dome. Electrodes loaded within a long, pliable needle were introduced through the adjacent intercostal space and implanted in each hemidiaphragm, at a 'tendinous' location (as close as possible to the entry of the nerve in the central tendon), and at a more lateral 'muscular' location. Postoperatively, the animals were ventilated using bilateral phrenic nerve stimulation. After euthanasia, abdominal verification of the electrodes position was performed through a laparotomy. The mediastinal and pleural parts of the procedure were uneventful. The insertion of electrodes was associated with transdiaphragmatic puncture and small abdominal haematomas in the first two animals studied. After a slight modification of the insertion technique, this was not observed anymore. Phrenic nerve stimulation produced efficient ventilation, with tidal volumes significantly higher when delivered at the tendinous site than at the muscular site. The trans-mediastinal implantation of intradiaphragmatic phrenic nerve stimulation electrodes is feasible, appears reasonably safe, and allows efficient ventilation.
High-tech rural clinics and hospitals in Japan: a comparison to the Japanese average.
Matsumoto, Masatoshi; Okayama, Masanobu; Inoue, Kazuo; Kajii, Eiji
2004-10-01
Japanese medical facilities are noted for being heavily equipped with high-tech equipment compared to other industrialised countries. Rural facilities are anecdotally said to be better equipped than facilities in other areas due to egalitarian health resource diffusion policies by public sectors whose goal is to secure fair access to modern medical technologies among the entire population. To show the technology status of rural practice and compare it to the national level. Nationwide postal survey. Questionnaires were sent to the directors of 1362 public hospitals and clinics (of the 1723 municipalities defined as 'rural' by four national laws). Information was collected about the technologies they possessed. The data were compared with figures from a national census of all hospitals and clinics. A total of 766 facilities responded (an effective response rate of 56%). Rural facilities showed higher possession rates in most comparable technologies than the national level. It is noted that almost all rural hospitals had gastroscopes and colonoscopes and their possession rates of bronchoscopes and dialysis equipment were twice as high as the national level. The discrepancy in possession rates between rural and national was even more remarkable in clinics than in hospitals. Rural clinics owned twice as many abdominal ultrasonographs, and three times as many gastroscopes, colonoscopes, defibrillators and computed tomography scanners as the national level. Rural facilities are equipped with more technology than urban ones. Government-led, tax based, technology diffusion in the entire country seems to have attained its goal. What is already known on this subject: As a general tendency in both developing and developed countries, rural medical facilities are technologically less equipped than their urban counterparts. What does this paper add?: In Japan, rural medical facilities are technologically better equipped than urban facilities.
[HL-A antigen distribution in duodenal ulcer patients].
Ilieva, P; Minev, M; Etŭrska, M
1980-01-01
The incidence of HLA-antigens was studied in 405 patients with clinically, roentgenologically and gastroscopically confirmed ulcer of duodenum and in 1085 controls, healthy subjects. Increased incidence of both antigens from locus B was established among the patients: HLA-B17 and HLA-BW21. A reduction of HLA-A3 incidence was found from the antigens of locus A. In the determination of incidence of HLA antigenes, depending on blood grouping ABO both of patients and healthy subjects, it was established that antigen HLA-A3 is less frequent in the patients with blood group B, whereas antigen HLA-B12 is found more often among the patients with blood group A.
Walker, Timothy D; Karemera, Martin; Ngabonziza, Francois; Kyamanywa, Patrick
2014-05-01
The study was undertaken to document the prevalence of Helicobacter pylori and endoscopic diagnoses in Rwandans presenting for gastroscopy. We studied an endoscopic database containing 961 consecutive gastroscopy patients at the University Teaching Hospital, Butare, over 12 months. Patient characteristics, endoscopic diagnoses and H. pylori status (by modified rapid urease testing) were analysed. The overall H. pylori positivity rate was 75% (n=825), similar to that found elsewhere in sub-Saharan Africa. Common endoscopic diagnoses included duodenal ulceration (20%), duodenitis (9%), benign gastric outlet obstruction (6%) and malignancy (5%). Duodenal ulceration was strongly associated with H. pylori infection (OR 6.2 [3.1-12.6]; p<0.001).
Coexistence of esophageal blue nevus, hair follicles and basaloid sqamous carcinoma: a case report.
Wang, Dong-Guan; Li, Xin-Gong; Gao, Hong; Sun, Xi-Yin; Zhou, Xiao-Qiu
2008-07-14
We present the case of a 57-year-old man who underwent esophagectomy for esophageal carcinoma found at barium meal and gastroscopic examination. He was diagnosed as esophageal basaloid squamous carcinoma (BSC) and gastric stromal tumor, which were associated with focal proliferation of melanocytes/pigmentophages and hair follicles in esophageal mucosa. Melanocytic hyperplasia (melanocytosis) has previously been recognized as an occasional reactive lesion, which can accompany esophageal inflammation and invasive squamous carcinoma. The present case is unusual because of its hyperplasia of not only melanocytes but also hair follicles. To our knowledge, this is the first report of esophageal blue nevus and hair follicle coexisting with BSC.
Zhu, Li-Huan; Du, Quan; Chen, Long; Yang, Shengsheng; Tu, Yuanrong; Chen, Shengping; Chen, Weisheng
2014-01-01
Thoracic sympathectomy is considered the most effective method to treat palmar hyperhidrosis. We developed a novel approach for thoracic sympathectomy in patients with palmar hyperhidrosis through the umbilicus, using an ultrathin gastroscope. The aim of this study was to evaluate the continuing efficacy and patient satisfaction of this innovative surgery. All procedures were performed under general anesthesia and the patients were intubated with a dual-lumen endotracheal tube. After a 5-mm umbilical incision, the muscular parts of the diaphragmatic dome were incised with a needle-knife and the nasal gastroscope was advanced into the thoracic cavity. The sympathetic chain was identified at the desired thoracic level and ablated with hot biopsy forceps. All patients were followed up for at least 1 year after the procedure through clinic visits or telephone/e-mail interviews. From April 2010 to August 2011, a total of 35 patients underwent a transumbilical thoracic sympathectomy. Fifty-seven percent were male patients, with a mean age of 21.2 years (range, 16-33 years). The success rate after 12 months was 97.1% (34 of 35) for isolated palmar hyperhidrosis and 72.2% (13 of 18) for axillary hyperhidrosis. Compensatory sweating was reported in 28.6% of patients at the 1-year follow-up evaluation. There was no mortality, no diaphragmatic hernia, and no Horner syndrome was observed. Quality of life related to hyperhidrosis improved substantially in 27 (77.1%) patients, and improved in 4 (11.4%) patients at 12 months after surgery. A total of 94.3% of patients were satisfied with the excellent cosmetic results of the surgical incision. Transumbilical thoracic sympathectomy is an efficacious alternative to the conventional approach. This technique avoided the chronic pain and chest wall paresthesia associated with the chest incision. In addition, this novel procedure afforded maximum cosmetic benefits. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Mueller, Ralf S; Olivry, Thierry
2017-08-30
The gold standard to diagnose adverse food reactions (AFRs) in the dog and cat is currently an elimination diet with subsequent provocation trials. However, those trials are inconvenient and client compliance can be low. Our objective was to systematically review the literature to evaluate in vivo and in vitro tests used to diagnose AFR in small animals. We searched three databases (CAB Abstracts, MEDLINE and Web of Science) for pertinent references on September 16, 2016. Among 71, 544 and 41 articles found in the CAB Abstract, MEDLINE and Web of Science databases, respectively, we selected 22 articles and abstracts from conference proceedings that reported data usable for evaluation of tests for AFR. Serum tests for food-specific IgE and IgG, intradermal testing with food antigens, lymphocyte proliferation tests, fecal food-specific IgE, patch, gastroscopic, and colonoscopic testing were evaluated. Testing for serum food-specific IgE and IgG showed low repeatability and, in dogs, a highly variable accuracy. In cats, the accuracy of testing for food-specific IgE was low. Lymphocyte proliferation tests were more frequently positive and more accurate in animals with AFR, but, as they are more difficult to perform, they remain currently a research tool. All other reported tests were only evaluated by individual studies with small numbers of animals. Negative patch test reactions have a very high negative predictability in dogs and could enable a choice of ingredients for the elimination diet in selected patients. Gastroscopic and colonoscopic testing as well as food-specific fecal IgE or food-specific serum IgG measurements appear less useful. Currently, the best diagnostic procedure to identify AFRs in small animals remains an elimination diet with subsequent provocation trials.
Walker, Timothy D.; Karemera, Martin; Ngabonziza, Francois; Kyamanywa, Patrick
2014-01-01
Background The study was undertaken to document the prevalence of Helicobacter pylori and endoscopic diagnoses in Rwandans presenting for gastroscopy. Methods We studied an endoscopic database containing 961 consecutive gastroscopy patients at the University Teaching Hospital, Butare, over 12 months. Patient characteristics, endoscopic diagnoses and H. pylori status (by modified rapid urease testing) were analysed. Results and conclusion The overall H. pylori positivity rate was 75% (n=825), similar to that found elsewhere in sub-Saharan Africa. Common endoscopic diagnoses included duodenal ulceration (20%), duodenitis (9%), benign gastric outlet obstruction (6%) and malignancy (5%). Duodenal ulceration was strongly associated with H. pylori infection (OR 6.2 [3.1–12.6]; p<0.001). PMID:24598794
Recurrent severe vomiting due to hyperthyroidism
Chen, Li-ying; Zhou, Bo; Chen, Zhou-wen; Fang, Li-zheng
2010-01-01
Thyrotoxicosis may present in many ways; severe vomiting as a prominent symptom of thyrotoxicosis is uncommon. In this paper, we report a 24-year-old Chinese male with hyperthyroidism who presented with recurrent severe vomiting. The patient had had intermittent vomiting for seven years and had lost approximately 15 kg of weight. Gastroscopic examinations revealed chronic gastritis and one occasion peptic ulcer. He was treated with antacid and proton pump inhibitors, but his symptoms had no relief. His presenting symptoms suggested hyperthyroidism and were confirmed by laboratory data. After a month of propylthiouracil therapy, his symptoms were relieved. It should be noted that hyperthyroidism patients can have unexplained vomiting, and that hyperthyroidism may coexist with peptic ulcer in rare cases. Awareness of such atypical presentations of hyperthyroidism may help to make a correct diagnosis. PMID:20205308
Case Report: Recurrent severe vomiting due to hyperthyroidism.
Chen, Li-ying; Zhou, Bo; Chen, Zhou-wen; Fang, Li-zheng
2010-03-01
Thyrotoxicosis may present in many ways; severe vomiting as a prominent symptom of thyrotoxicosis is uncommon. In this paper, we report a 24-year-old Chinese male with hyperthyroidism who presented with recurrent severe vomiting. The patient had had intermittent vomiting for seven years and had lost approximately 15 kg of weight. Gastroscopic examinations revealed chronic gastritis and one occasion peptic ulcer. He was treated with antacid and proton pump inhibitors, but his symptoms had no relief. His presenting symptoms suggested hyperthyroidism and were confirmed by laboratory data. After a month of propylthiouracil therapy, his symptoms were relieved. It should be noted that hyperthyroidism patients can have unexplained vomiting, and that hyperthyroidism may coexist with peptic ulcer in rare cases. Awareness of such atypical presentations of hyperthyroidism may help to make a correct diagnosis.
Endoscopic findings of the stomach in pleasure horses in Poland
2013-01-01
Background This study was performed to determine the prevalence of ulcers in the gastric squamous and glandular mucosa in Polish pleasure horses. Study design Medical records from gastroscopic examinations of 108 pleasure horses of different breeds were reviewed. The study population consisted of two groups; group I (n = 48) with horses that expressed mild clinical signs of gastric ulcer syndrome (EGUS) including poor appetite, slight weight loss or poor body condition, and group II (n = 60) with horses that had no signs of gastrointestinal problems. The age range was 4–10 years, including 5 males, 34 castrated males (geldings) and 69 mares. The prevalence, distribution and severity of gastric ulcers were recorded. Lesions involving the squamous mucosa and the glandular mucosa of the antrum and pylorus were graded and compared between groups. Results Significant difference was found in the presence and severity of gastric ulcers between the two groups of horses. The overall prevalence of gastric ulcers in the first group of horses (n = 48) was 59% while in the group of clinically healthy horses (n = 60) the prevalence of gastric lesion was 40% (P = 0.004). Almost 19% of horses from group I had between 6–10 lesions (EGUS score III) and nearly 19% had either >10 localized lesions or very large diffuse lesions (EGUS number score IV). The number of ulcerations in affected horses were significantly lower in group II compared to group I (P = 0.016) as 10% of horses had 6–10 lesions (EGUS number score III) and nearly 14% had either >10 localized lesions or very large diffuse lesions (EGUS number score IV). Gastroscopy revealed that nearly 32% of horses from the second group had an ulceration EGUS score ≥ II. Discussion and conclusions This study confirms that gastric ulcerations can be prevalent in apparently clinically normal pleasure horses and a complete gastroscopic examination including the examination of the pylorus is advisable to evaluate this syndrome. PMID:24044656
Chen, Zhi-Hua; Lin, Su-Yong; Dai, Qi-Bao; Hua, Jin; Chen, Shao-Qin
2017-04-10
We examined gastric outlet obstruction (GOO) patients who received two weeks of strengthening pre-operative enteral nutrition therapy (pre-EN) through a nasal-jejenal feeding tube placed under a gastroscope to evaluate the feasibility and potential benefit of pre-EN compared to parenteral nutrition (PN). In this study, 68 patients confirmed to have GOO with upper-gastrointestinal contrast and who accepted the operation were randomized into an EN group and a PN group. The differences in nutritional status, immune function, post-operative complications, weight of patients, first bowel sound and first flatus time, pull tube time, length of hospital stay (LOH), and cost of hospitalization between pre-operation and post-operation were all recorded. Statistical analyses were performed using the chi square test and t -test; statistical significance was defined as p < 0.05. The success rate of the placement was 91.18% (three out of 31 cases). After pre-EN, the levels of weight, albumin (ALB), prealbumin (PA), and transferrin (TNF) in the EN group were significantly increased by pre-operation day compared to admission day, but were not significantly increased in the PN group; the weights in the EN group were significantly increased compared to the PN group by pre-operation day and day of discharge; total protein (TP), ALB, PA, and TNF of the EN group were significantly increased compared to the PN group on pre-operation and post-operative days one and three. The levels of CD3+, CD4+/CD8+, IgA, and IgM in the EN group were higher than those of the PN group at pre-operation and post-operation; the EN group had a significantly lower incidence of poor wound healing, peritoneal cavity infection, pneumonia, and a shorter first bowel sound time, first flatus time, and post-operation hospital stay than the PN group. Pre-EN through a nasal-jejunum feeding tube and placed under a gastroscope in GOO patients was safe, feasible, and beneficial to the nutrition status, immune function, and gastrointestinal function, and sped up recovery, while not increasing the cost of hospitalization.
Matsumoto, M; Hanrath, P; Kremer, P; Tams, C; Langenstein, B A; Schlüter, M; Weiter, R; Bleifeld, W
1982-01-01
In order to evaluate left ventricular function during dynamic exercise transoesophageal M-mode recordings of the left ventricle were carried out with a newly developed transducer gastroscope system. Twelve healthy subjects performed a graded supine bicycle exercise test. Stable and good quality images of the left ventricle at rest and during exercise at different steps up to a maximum workload of 100 watts were obtained in all patients. Isotonic maximum exercise resulted in a significant increase in fractional shortening of the left ventricle, peak shortening rate, and peak lengthening rate of the left ventricular minor axis. Left ventricular end-diastolic dimension decreased significantly. With increasing workload the pressure rate product increased significantly. It is concluded that transoesophageal M-mode echocardiography is a useful method of evaluating left ventricular performance during dynamic exercise. Images PMID:7082515
[Stomach ulcers in the horse--clinical and gastroscopic findings in 12 horses (1989-1990)].
Dieckmann, M; Deegen, E
1991-08-01
Twelve horses with clinical symptoms of a gastric disorder were studied by gastroscopy. Symptoms of gastric disorders were periprandial colic, bruxism, ructus and reflux. Preliminary to gastroscopy the horses were fasted for 24 h. Access to water was not restricted. The gastroscopy could be conducted easily using a fiberscope 2.5 m in length and 11 mm in outer diameter. While ulcers were present in the squamous fundus of all horses only one horse showed ulceration of the glandular fundus. Solitary ulcers near the margo plicatus were found in horses with mild clinical symptoms. In contrast, diffuse gastroesophageal ulceration was accompanied by severe clinical symptoms. Four horses were affected by an acute gastroesophageal ulceration with gastric reflux and subsequent aspiration pneumonia. Two of those horses suffered from acute gastric ulceration 3-4 days following laparatomy. All horses were treated with cimetidine (5 mg/kg bwt/q.i.d.) until clinical symptoms ceased.
Blood flow estimation in gastroscopic true-color images
NASA Astrophysics Data System (ADS)
Jacoby, Raffael S.; Herpers, Rainer; Zwiebel, Franz M.; Englmeier, Karl-Hans
1995-05-01
The assessment of blood flow in the gastrointestinal mucosa might be an important factor for the diagnosis and treatment of several diseases such as ulcers, gastritis, colitis, or early cancer. The quantity of blood flow is roughly estimated by computing the spatial hemoglobin distribution in the mucosa. The presented method enables a practical realization by calculating approximately the hemoglobin concentration based on a spectrophotometric analysis of endoscopic true-color images, which are recorded during routine examinations. A system model based on the reflectance spectroscopic law of Kubelka-Munk is derived which enables an estimation of the hemoglobin concentration by means of the color values of the images. Additionally, a transformation of the color values is developed in order to improve the luminance independence. Applying this transformation and estimating the hemoglobin concentration for each pixel of interest, the hemoglobin distribution can be computed. The obtained results are mostly independent of luminance. An initial validation of the presented method is performed by a quantitative estimation of the reproducibility.
Gastroscopic screening in 80 patients with pernicious anaemia.
Stockbrügger, R W; Menon, G G; Beilby, J O; Mason, R R; Cotton, P B
1983-01-01
We have studied 80 patients with pernicious anaemia. Upper gastrointestinal endoscopy (with biopsy and cytology) showed no lesion other than atrophic gastritis in 34 patients. Thirty three patients, however, had varying degrees of gastric mucosal dysplasia, which was detected more frequently by histology than by cytology. The endoscopic appearance of the mucosa was abnormal in four of the six patients with moderate dysplasia, and in all three patients with severe dysplasia. One patient was found to have a small carcinoma in the gastric antrum, and underwent total gastrectomy; 18 patients had polyps (often multiple); four of these were treated by endoscopic polypectomy. One of the patients with polyps had multiple carcinoid tumours, and an asymptomatic parathyroid adenoma. Seventeen of the patients also underwent barium meal examination; abnormalities were revealed in only three of the seven patients with lesions visible at endoscopy. Our results justify further endoscopic studies in patients with pernicious anaemia, and sequential examinations to establish the natural history of gastric dysplasia. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:6642278
Patrzyk, M; Schreiber, A; Heidecke, C D; Glitsch, A
2009-12-01
Development of an innovative method of endoscopic laser-supported diaphanoscopy, for precise demonstration of the location of gastrointestinal stromal tumors (GISTs) at laparoscopy is described. The equipment consists of a light transmission cable with an anchoring system for the gastric mucosa, a connecting system for the light source, and the laser light source itself. During surgery, transillumination by laser is used to show the shape of the tumor. The resection margins are then marked by electric coagulation. Ten patients have been successfully treated using this technique in laparoscopic-endoscopic rendezvous procedures. Average time of surgery was 123 minutes. The time for marking the shape of the tumor averaged 16 minutes. Depending on tumor location and size, 4-7 marks were used, and resection margins were 4-15 mm. This new and effective technique facilitates precise locating of gastric GISTs leading to exact and tissue-sparing transmural laparoscopic resections. Georg Thieme Verlag KG Stuttgart New York.
Zhao, Hong; Cheng, Jilin; Xu, Yahong; Lu, Cuili; Huang, Shaoping; Fan, Zhenyu; Shi, Yuxin
2014-01-01
Sclerotherapy and endoscopic esophageal variceal ligation (EVL) are commonly used to treat and prevent variceal bleeding. As of today, there has been no report on an unexpected incarceration of a varix hooked on with the bands from the endoscopic EVL device. We recently experienced this emergency while using the 7-band ring endoscopic EVL device (Boston Scientific Corp., Boston, MA) for prophylaxis of variceal bleeding. In this case, the varix body itself was accidently incarcerated in the crevice of the esophageal endoscope after highly negative pressure of absorption was applied on the endoscope. In this situation, using force to take out the gastroscope was not an option as it would tear the vein and cause massive hemorrhage. We were managed to ligate the varix with rubber bands while releasing the incarceration. We observed that ligation of the varix at the same position using all seven ligation bands resulted in disappearance of the targeted varix. The surrounding esophageal mucosa became smooth after the treatment. PMID:25550983
Stress reduction through listening to Indian classical music during gastroscopy.
Kotwal, M R; Rinchhen, C Z; Ringe, V V
1998-01-01
The purpose of this study was to examine the effects of music on elevated state of anxiety as many patients become stressed and anxious during diagnostic procedures. The study was conducted on 104 consecutive patients undergoing GI endoscopy for various reasons. Patients were randomly assigned to two groups regardless of sex, age and underlying disease. One group of 54 patients were made to listen to a recorded Indian classical instrumental music before and during the procedure, while the other group of 50 patients did not. Blood pressure, heart rate and respiratory rate were recorded at the beginning of consultation and end of procedure. Perception of procedure using a three point attitude scale was assessed. Our results indicate that the background Indian classical music is efficacious in reducing psychological distress during a gastroscopic examination. We suggest that music could be applied to other medical situations as well, which tend to generate undue psychological stress and anxiety. Music, as a familiar personal and culture medium, can be used to ease anxiety, to act as distractor, to increase discomfort and pain threshold.
Zhang, Wan; Li, Bolin; Sun, Jianhui; Wang, Zhikun; Zhang, Nana; Shi, Fang; Pei, Lin
2017-07-12
To compare the differences in the clinical therapeutic effects on reflux esophagitis among the combined therapy of huazhuo jiedu jiangni decoction (the decoction for resolving the turbid, detoxification and reducing the pathologic upward qi in short) and acupuncture, omeprazole and Chinese herbal medicine. Ninety patients were randomized into 3 groups, 4 cases of them were dropped off. Finally, there were 29 cases in the combined therapy group with acupuncture and the decoction, 29 cases in the western medication group and 28 cases in the Chinese herbal medicine group in the statistical analysis. In the combined therapy group with acupuncture and the decoction, the decoction was prescribed recurrence rate. The therapeutic effects are better than the simple application of either Chinese herbal medicine or omeprazole. for oral administration. Additionally, acupuncture was applied to Neiguan (PC 6), Zusanli (ST 36), Zhongwan (CV 12), Ganshu (BL 18), Danshu (BL 19) and Taichong (LR 3). The decoction was applied one dose a day and acupuncture was once a day. In the western medication group, omeprazole capsules, 20 mg were prescribed for oral administration, twice a day. In the Chinese herbal medicine group, the decoction was simply applied. The treatment was 8 weeks in the 3 groups and the follow-up visit was 6 months. The score of reflux disorder questionnaire (RDQ) and the changes in esophageal mucosa under gastroscope were observed before and after treatment; the clinical therapeutic effects and recurrence rate were evaluated in the 3 groups. In 4 and 8 weeks of treatment, RDQ scores in the 3 groups were all reduced as compared with those before treatment (all P <0.05). In 4 weeks of treatment, RDQ score in the combined therapy group with acupuncture and Chinese herbal medicine was lower than that in the western medication group ( P <0.05). In 8 weeks of treatment, RDQ score in the combined therapy group with acupuncture and Chinese herbal medicine was lower than those in the western medication group and the Chinese herbal medicine group (both P <0.05). In follow-up visit for 6 months, the recurrence rate in the combined therapy group with acupuncture and the decoction was lower than those in the other two groups (both P <0.05). In 8 weeks of treatment, the total effective rate for clinical symptoms and that observed under gastroscope in the combined therapy group with acupuncture and the decoction were all better than those in the western medication group and the Chinese herbal medicine group (all P <0.05). The combined therapy of huazhuo jiedu jiangni decoction and acupuncture achieve the definite therapeutic effects on reflux esophagitis, relieve the symptoms, protect gastric mucosa and reduce the.
Li, Cuiying; Li, Jinxiang; Pan, Shimin; Zhang, Xi; Li, Ying
2017-08-12
To compare the effects differences for peptic ulcer between acupuncture based on the theory of "the compatibility of the five meridians" in Huxiang and conventional western medication. Sixty patients with peptic ulcer of liver-stomach disharmony type (LSDT) and weakness of spleen and stomach type (WSST) were assigned into an observation group and a control group by block randomization according to syndrome differentiation.Finally,28 cases (17 with LSDT and 11 with WSST) in the observation group,29 cases (18 with LSDT and 11 with WSST) in the control group were included.In the observation group,patients with LSDT were treated with acupuncture at Zhongwan (CV 12),Taichong (LR 3),Xingjian (LR 2),Qimen (LR 14),Zusanli (ST 36),Gongsun (SP 4),Shaofu (HT 8),Jingqu (LU 8),Neiguan (PC 6); those with WSST,at Zhongwan (CV 12),Dadu (SP 2),Taibai (SP 3),Yinlingquan (SP 9),Zusanli (ST 36),Shaofu (HT 8), Taichong (LR 3),Yingu (KI 10),Taixi (KI 3),Taiyuan (LU 9) according to the theory of "the compatibility of the five meridians" in Huxiang .Reinforcing and reducing were according to syndrome differentiation.The treatment was given once a day with needle retained for 30 min,5 days a week,2 days at interval.In the control group,the conventional triple drugs (omeprazole,amoxicillin and clarithromycin) were prescribed orally for Hp positive patients,and omeprazole for Hp negative patients.All the patients were treated for 4 weeks.The clinical syndrome score,ulcer healing under gastroscope,anti-Hp infection and Hp negative conversion ratio rate were observed in the two groups before and after treatment as well as 1 month after treatment.The total effects were evaluated. The syndrome scores after treatment and at 1 month ofter treatment decreased in the two groups (all P <0.05),while without significant difference between the two groups (both P >0.05).The scores within the group between the two syndromes showed no significance in the two groups (both P >0.05).The cure rates under gastroscope,anti-Hp infection rates and the total rates had no statistically significant difference between the two groups (all P >0.05).The Hp negative conversion ratio was 22.2%(4/18) in the observation group,which was worse than 52.6%(10/19) in the control group ( P <0.05). Acupuncture based on the theory of "the compatibility of the five meridians" in Huxiang for peptic ulcer can improve clinical symptoms,ulcer coalescence and anti-Hp infection,which is similar to conventional western medication.While the Hp negative conversion ratio is less than that of conventional western medicine.
Front-end receiver electronics for a matrix transducer for 3-D transesophageal echocardiography.
Yu, Zili; Blaak, Sandra; Chang, Zu-yao; Yao, Jiajian; Bosch, Johan G; Prins, Christian; Lancée, Charles T; de Jong, Nico; Pertijs, Michiel A P; Meijer, Gerard C M
2012-07-01
There is a clear clinical need for creating 3-D images of the heart. One promising technique is the use of transesophageal echocardiography (TEE). To enable 3-D TEE, we are developing a miniature ultrasound probe containing a matrix piezoelectric transducer with more than 2000 elements. Because a gastroscopic tube cannot accommodate the cables needed to connect all transducer elements directly to an imaging system, a major challenge is to locally reduce the number of channels, while maintaining a sufficient signal-to-noise ratio. This can be achieved by using front-end receiver electronics bonded to the transducers to provide appropriate signal conditioning in the tip of the probe. This paper presents the design of such electronics, realizing time-gain compensation (TGC) and micro-beamforming using simple, low-power circuits. Prototypes of TGC amplifiers and micro-beamforming cells have been fabricated in 0.35-μm CMOS technology. These prototype chips have been combined on a printed circuit board (PCB) to form an ultrasound-receiver system capable of reading and combining the signals of three transducer elements. Experimental results show that this design is a suitable candidate for 3-D TEE.
System for clinical photometric stereo endoscopy
NASA Astrophysics Data System (ADS)
Durr, Nicholas J.; González, Germán.; Lim, Daryl; Traverso, Giovanni; Nishioka, Norman S.; Vakoc, Benjamin J.; Parot, Vicente
2014-02-01
Photometric stereo endoscopy is a technique that captures information about the high-spatial-frequency topography of the field of view simultaneously with a conventional color image. Here we describe a system that will enable photometric stereo endoscopy to be clinically evaluated in the large intestine of human patients. The clinical photometric stereo endoscopy system consists of a commercial gastroscope, a commercial video processor, an image capturing and processing unit, custom synchronization electronics, white light LEDs, a set of four fibers with diffusing tips, and an alignment cap. The custom pieces that come into contact with the patient are composed of biocompatible materials that can be sterilized before use. The components can then be assembled in the endoscopy suite before use. The resulting endoscope has the same outer diameter as a conventional colonoscope (14 mm), plugs into a commercial video processor, captures topography and color images at 15 Hz, and displays the conventional color image to the gastroenterologist in real-time. We show that this system can capture a color and topographical video in a tubular colon phantom, demonstrating robustness to complex geometries and motion. The reported system is suitable for in vivo evaluation of photometric stereo endoscopy in the human large intestine.
Drick, N; Patecki, M; Arelin, V; Schmidt, J J; Wahl, O; Kielstein, J T
2015-10-01
Over the last decade, there has been a paradigm shift in the extracorporeal treatment of intoxications. The availability of new treatment options, especially new membranes has led to a decrease in the use of techniques like charcoal hemoperfusion, once considered the gold standard to eliminate highly protein bound substances. The EXtracorporeal Treatments In Poisoning (EXTRIP) workgroup is a collaborative international effort of pharmacologists, toxicologists, critical care physicians, and nephrologists that is reviewing all available evidence in extracorporeal procedures for the treatment of poisonings in a standardized way to distill treatment recommendations for the physician at the bedside. One of the first available EXTRIP guidelines summarizes treatment recommendations for severe carbamazepine intoxications. We report the case of a 43-year-old Caucasian woman with who ingested about 21 g carbamazepine in a suicidal attempt together with alcohol. Combining gastroscopic removal of carbamazepine and multiple dose activated charcoal with intermittent high-flux hemodialysis lowered the initial carbamazepine level of 56.5 mg/l (47 mg/l before dialysis) to 25 mg/l. The patient, who initially required mechanical ventilation could be transferred to the psychiatric ward 24 h after ICU admission.
Gastroscopy: a primary diagnostic procedure.
Coleman, W H
1988-03-01
EGD, using 1986 models of either the fiberoptic gastroscope or the videoscope, is a safe and accurate procedure that can be performed by any physician trained in the technique of endoscope passage. It may be performed at large medical centers or small rural hospitals, outpatient clinics, or even private offices. Patients themselves have indicated preference for endoscopic evaluation over the double-contrast barium meal after they have experienced both procedures. The short time of procedure, its accuracy, safety, and its relative lack of discomfort to the patient lend it readily to being an initial component in the primary evaluation of symptoms of abdominal distress, gastrointestinal bleeding, dysphagia, esophageal reflux, persistent vomiting, and odynophagia. It is essential in the evaluation of complications of esophageal reflux and the evaluation of abnormal radiological findings in the upper gastrointestinal tract. It should never be overlooked in evaluating the patient with iron deficiency anemia of unknown etiology. Economic pressures have already moved EGD from the surgery wards to endoscopy labs and to the outpatient setting. These same forces will project more physicians into the role of the diagnostic endoscopist and the patient will benefit by decreased medical costs, quicker diagnosis and treatment, and enhanced continuity of care.
Gastroenterology service in a teaching hospital in rural New Zealand, 1991-2003
Schultz, Michael; Davidson, Andrew; Donald, Sarah; Targonska, Bogna; Turnbull, Angus; Weggery, Susan; Livingstone, Vicki; Dockerty, John D
2009-01-01
AIM: To retrospectively collect inpatient and outpatient data and to assess the use of endoscopic procedures during the years 1991, 1997 and 2003 to analyse for trends. METHODS: This retrospective survey was conducted in a University-associated Gastroenterology Unit offering secondary and tertiary health care services for a population of approximately 182 000 people in Southern New Zealand. Data collected included patient contacts (in- and outpatients), gastroscopic and colonoscopic investigations. RESULTS: We observed a significant increase in the absolute numbers of patient contacts over the years (1991: 2308 vs 1997: 2022 vs 2003: 2783, P < 0.0001) with inflammatory bowel disease, other diseases of the colon, anus and rectum and iron studies related disorders decreasing significantly but liver disease and constipation increasing linearly over time. The use of endoscopy services remained relatively stable but colonoscopic investigations for a positive family history of colorectal cancer increased significantly while more gastroscopies were performed for unexplained anaemia. CONCLUSION: The whole spectrum of gastroenterology contacts was studied. A substantial proportion of colonoscopies and outpatient consultations were undertaken to screen for colorectal cancer. This proportion is likely to grow further. Our findings have implications for the recruitment and training of the next generation of gastroenterologists. PMID:19195060
Gastrointestinal stromal tumors.
Sekac, J; Labas, P; Skultety, J; Prochotsky, A; Durdik, J; Hrbaty, B
2008-01-01
In the last 3 years 9 patients with gastrointestinal stromal tumors (GIST) underwent surgery at our department. All cases were with very atypical process. From these patients 3 interesting cases are described in more details. A 75-years-old woman with gastroscopically verified endoluminal tumour in the proximal third of stomach, 6x7 cm, 76-years-old man with a large endoluminal tumour in D2-D3 part of the duodenum, 4x4 cm, and 62-years-old man with verified extraluminal tumour by CT examination in the middle part of stomach. In all cases, gastrointestinal stromal tumour was histologically confirmed. Work is well photo-documented pre-surgically with endoscopic and CT-findings and during surgery: individual steps during the removal of these tumours. In assessment of the size and number of mitoses, tumours belonged to a group with highly malignant potential. Patients are regularly checked in 3-months intervals and also examination by positron emission tomography was performed--it seems to have the best demonstrability of possible relapse. All three patients live and are subjectively and objectively without significant problems (Tab. 5, Fig. 5, Ref. 7). Full Text (Free, PDF) www.bmj.sk.
Yang, Kun; Chen, Xinzu; Zhang, Weihan; Chen, Xiaolong; Hu, Jiankun
2016-08-25
To investigate the feasibility and safety of Da Vinci surgical robot in the dissection of splenic hilar lymph nodes for gastric cancer patients with total gastrectomy. Clinical data of two cases who underwent total gastrectomy for cardia cancer at our department in January 2016 were analyzed retrospectively. Two male patients were 62 and 55 years old respectively, with preoperative diagnosis as cT2-3N0M0 and cT1-2N0M0 gastric cancer by gastroscope and biopsy, and both received robotic total gastrectomy spleen-preserving splenic hilar lymph node dissection successfully. The operative time for splenic hilar lymph node dissection was 30 min and 25 min respectively. The intraoperative estimated blood loss was both 100 ml, while the number of total harvested lymph node was 38 and 33 respectively. One dissected splenic hilar lymph node and fatty tissues in two patients were proven by pathological examinations. There were no anastomotic leakage, pancreatic fistula, splenic infarction, intraluminal bleeding, digestive tract bleeding, aneurysm of splenic artery, and other operation-associated complications. Both patients suffered from postoperative pneumonia, and were cured by conservative therapy. The robotic spleen-preserving splenic hilar lymph node dissection is feasible and safe, but its superiority needs further evaluation.
Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing.
Ofstead, Cori L; Wetzler, Harry P; Johnson, Ellen A; Heymann, Otis L; Maust, Thomas J; Shaw, Michael J
2016-11-01
During a study designed to assess endoscope reprocessing effectiveness, a borescope was used to examine lumens and ports. Cloudy, white, viscous fluid was observed inside fully reprocessed gastroscopes and colonoscopes. This fluid resembled simethicone, which is commonly administered to reduce foam and bubbles that impede visualization during gastrointestinal endoscopy. This article describes methods used to determine whether the observed fluid contained simethicone. Photographs of residual fluid were taken using a borescope. Sterile cotton-tipped swabs were used to collect samples of fluid observed in 3 endoscope ports. Samples were evaluated using Fourier transform infrared spectroscopy (FTIR)-attenuated total reflection analysis. Residual fluid was observed inside 19 of 20 endoscopes. Fluid photographed in 8 endoscopes resembled simethicone solutions. FTIR analysis confirmed the presence of simethicone in 2 endoscopes. Fluid containing simethicone remained inside endoscopes despite reprocessing. Simethicone is an inert, hydrophobic substance that may reduce reprocessing effectiveness. Simethicone solutions commonly contain sugars and thickeners, which may contribute to microbial growth and biofilm development. Studies are needed to assess the prevalence of residual moisture and simethicone in endoscopes and determine the impact on reprocessing effectiveness. We recommend minimizing the use of simethicone pending further research into its safety. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Comparison of methods for quantitative evaluation of endoscopic distortion
NASA Astrophysics Data System (ADS)
Wang, Quanzeng; Castro, Kurt; Desai, Viraj N.; Cheng, Wei-Chung; Pfefer, Joshua
2015-03-01
Endoscopy is a well-established paradigm in medical imaging, and emerging endoscopic technologies such as high resolution, capsule and disposable endoscopes promise significant improvements in effectiveness, as well as patient safety and acceptance of endoscopy. However, the field lacks practical standardized test methods to evaluate key optical performance characteristics (OPCs), in particular the geometric distortion caused by fisheye lens effects in clinical endoscopic systems. As a result, it has been difficult to evaluate an endoscope's image quality or assess its changes over time. The goal of this work was to identify optimal techniques for objective, quantitative characterization of distortion that are effective and not burdensome. Specifically, distortion measurements from a commercially available distortion evaluation/correction software package were compared with a custom algorithm based on a local magnification (ML) approach. Measurements were performed using a clinical gastroscope to image square grid targets. Recorded images were analyzed with the ML approach and the commercial software where the results were used to obtain corrected images. Corrected images based on the ML approach and the software were compared. The study showed that the ML method could assess distortion patterns more accurately than the commercial software. Overall, the development of standardized test methods for characterizing distortion and other OPCs will facilitate development, clinical translation, manufacturing quality and assurance of performance during clinical use of endoscopic technologies.
A non-invasive navigation system for retargeting gastroscopic lesions.
Liu, Jiquan; Wang, Bin; Hu, Weiling; Zong, Yun; Si, Jianmin; Duan, Huilong
2014-01-01
Biopsy is a traditional endoscopic surveillance of premalignant gastric lesions, and endoscopic tattooing is used for marking the biopsy's location. However, the tattooing has several disadvantages. For example, the procedure is an invasive operation and may not be durable due to the diffusion. Moreover, it is procedurally cumbersome with an associated risk of technical failure. In this study, a computer aided endoscopic navigation system (CAEN system) was developed for a non-invasive biopsy procedure. The CAEN system consists of a new, designed six degree of freedom (6-DOF) tracking endoscope device and a computer simulated work station. During the procedure, the endoscopist uses the tip of the tracking endoscope to touch the lesion. Then, the lesion's location is recorded in the work station, which then guides the endoscopist in retargeting the lesions in the follow-ups. The clinical experimental results demonstrate that the accuracy at the angularis is 5.2 ± 2.8 mm, at the antral lesser curvature is 7.2 ± 2.0 mm, at the antral greater curvature is 6.3 ± 3.1 mm, at the antral posterior wall is 8.2 ± 1.6 mm, and at the antral anterior wall is 7.9 ± 1.3 mm. The mean accuracy is 7.5 mm, and the P-value is 0.023, which is likely suitable for clinical practice. Furthermore, the proposed CAEN system requires less procedural time than the tattooing.
Chang, Young Woon; Jang, Jae Young; Kim, Yong Ho; Kim, Jung-Wook; Shim, Jae-Jun
2015-01-01
Background/Aims The aims of this study were to investigate whether a broccoli sprout extract containing sulforaphane (BSES) inhibited the Helicobacter pylori infection density and exerted an antioxidative effect on gastric mucosal damage. Methods The enrolled subjects were randomized in a double-blinded manner into three groups. Finally, 33 H. pylori (+) BSES treatment subjects (group A), 28 H. pylori (+) placebo subjects (group B), and 28 H. pylori (−) BSES treatment subjects (group C) were studied. H. pylori infection density was indirectly quantified by a 13C-urea breath test (UBT), and the ammonia concentration in gastric juice aspirates was measured through gastroscopic examination. Malondialdehyde (MDA), an oxidative damage biomarker, and reduced glutathione (GSH), an antioxidant biomarker, were measured in the gastric mucosa by an enzyme-linked immunosorbent assay. Results BSES treatment did not significantly affect the UBT values or ammonia concentration in group A (p=0.634 and p=0.505, respectively). BSES treatment did significantly reduce mucosal MDA concentrations in group A (p<0.05) and group C (p<0.001), whereas the gastric mucosal GSH concentrations did not differ before and after treatment in any of the groups. Conclusions BSES did not inhibit the H. pylori infection density. However, BSES prevented lipid peroxidation in the gastric mucosa and may play a cytoprotective role in H. pylori-induced gastritis. PMID:25287166
Zhang, Jing-Xi; Zhan, Xian-Bao; Bai, Chong; Li, Qiang
2015-02-07
Belching is a common symptom of gastroesophageal reflux disease. If the symptoms are not relieved after anti-reflux treatment, another etiology should be considered. Here, we report a case of a 43-year-old man who presented with belching, regurgitation, chest tightness and dyspnea for 18 mo, which became gradually more severe. Gastroscopic examination suggested superficial gastritis. Twenty-four-hour esophageal pH monitoring showed that the Demeester score was 11.4, in the normal range. High-resolution manometry showed that integrated relaxation pressure and intrabolus pressure were higher than normal (20 mmHg and 22.4 mmHg, respectively), indicating gastroesophageal junction outflow tract obstruction. Pulmonary function test showed severe obstructive ventilation dysfunction [forced expiratory volume in 1 second (FEV1)/forced vital capacity 32%, FEV1 was 1.21 L, occupying 35% predicted value after salbuterol inhalation], and positive bronchial dilation test (∆FEV1 260 mL, ∆FEV1% 27%). Skin prick test showed Dermatophagoides farinae (++), house dust mite (++++), and shrimp protein (++). Fractional exhaled nitric oxide measurement was 76 ppb. All the symptoms were alleviated completely and pulmonary function increased after combination therapy with corticosteroids and long-acting β2-agonist. Bronchial asthma was eventually diagnosed by laboratory tests and the effect of anti-asthmatic treatment, therefore, physicians, especially the Gastrointestinal physicians, should pay attention to the belching symptoms of asthma.
The atopic dog: a model for food allergy.
Ermel, R W; Kock, M; Griffey, S M; Reinhart, G A; Frick, O L
1997-02-01
The renewed interest in food allergy and its investigation has been hampered by the lack of an appropriate animal model with similar comparative aspects of form and function relative to humans. Therefore we have been characterizing an inbred colony of high immunoglobulin E-producing dogs that were immunized subcutaneously with food antigen extracts in alum and that developed clinical manifestations of food allergy after oral challenges with food antigen. These dogs had appreciably high IgE antibody titer to specific food antigens, as measured by an enzyme-labeled immunodot assay. Skin test results for the food antigens were consistently positive, as evidenced by a wheal-and-flare reaction. Gastroscopic food sensitivity was tested through an endoscope by injecting allergenic food extracts into the gastric mucosa after intravenous injection of Evans blue dye. Mucosal changes included swelling and erythema, some petechiae and blue patching, and in some instances generalized gastric erythema and hyperperistalsis. Examination of immediate-reaction biopsy specimens revealed edema and few inflammatory cells. Examination of late-reaction biopsy specimens revealed increased eosinophil and mononuclear cell infiltrations typical of late-phase allergic inflammatory responses. Direct mucosal challenge with food extracts confirmed the clinical and immunologic evidence of food allergy in these immunized dogs and suggests the usefulness of the atopic dog as a model for food allergy. This model might also be useful in detecting hidden food allergies in unexplained inflammatory gastrointestinal tract diseases.
Septotomy and Balloon Dilation to Treat Chronic Leak After Sleeve Gastrectomy: Technical Principles.
Campos, Josemberg Marins; Ferreira, Flávio Coelho; Teixeira, André F; Lima, Jones Silva; Moon, Rena C; D'Assunção, Marco Aurélio; Neto, Manoel Galvão
2016-08-01
Chronic leaks after laparoscopic sleeve gastrectomy (LSG) are often difficult to treat by endoscopy metallic stent. Septotomy has been indicated as an effective procedure, but the technical aspects have not been detailed in previous publications (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007; Baretta G, Campos J, Correia S, et al., Surg Endosc 29(7):1714-20, 2015; Campos JM, Pereira EF, Evangelista LF, et al., Obes Surg 21(10):1520-9, 2011). We herein present a video (6 min) demonstrating the maneuver principles of this technique, showing it as a safe and feasible approach. A 32-year-old male, with BMI 43.4 kg/m(2), underwent LSG. On the tenth POD, he presented with a leak and initially was managed with the following approach: laparoscopic exploration, drainage, endoclips, and 20-mm balloon dilation. However, the leak remained for a period of 6 months. On the endoscopy, a septum was identified between the leak site and gastric pouch, so it was decided to "reshape" this area by septotomy. Septotomy procedure: Sequential incisions were performed using argon plasma coagulation (APC) with 2.5 flow and 50 W (WEM, SP, Brazil) over the septum in order to allow communication between the perigastric cavity (leak site) and the gastric lumen. The principles below must be followed: (1) Scope position: the endoscopist's left hand holds the control body of the gastroscope while the right hand holds the insertion tube; the APC catheter has no need to be fixed. This avoids movements and unprogrammed maneuvers. (2) Before cutting, the septum is placed in the six o'clock position on the endoscopic view, by rotating the gastroscope. (3) The septum is sectioned until the bottom of the perigastric cavity (leak site). (4) That section is made towards the staple line. (5) Just after the septotomy, a Savory-Gilliard guidewire (Cook Medical, Indiana, USA) through the scope must be inserted until the duodenum, followed by 30-mm balloon (Rigiflex®, Boston Scientific, MA, USA) insertion. The balloon catheter must be firmly held during gradual inflation (maximum 10 psi) to avoid slippage and laceration. This allows increasing the gastric lumen. (6) Septotomy by electrocautery with a needle knife (Boston Scientific, MA, USA) can be made when an intensive fibrotic septum is present; bleeding is rare in this case. In this case, the endoclip previously used was removed from the septum with forceps to avoid heat transmission. Small staples visualized in the fistula orifice were not completely removed due to technical difficulties and friable tissue. Two sessions were performed in 15 days, resulting in leak closure. The patient was submitted to radiological control 1 week after the second session, which revealed fistula healing, without gastric stenosis. The nasoduodenal feeding tube remained for 7 days, when the patient started oral diet. This patient was followed for 18 months without recurrence. Septotomy and balloon dilation were initially performed on a difficult-to-treat chronic fistula after gastric bypass and named before as stricturotomy (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007). This procedure allows internal drainage of the fistula and deviates oral intake to the pouch. In addition, achalasia balloon dilation treats strictures and axis deviation of the gastric chamber, promoting reduction of the intragastric pressure. Septotomy and balloon dilation are technically feasible and might be useful in selected cases for closure of chronic leaks after LSG.
Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R
2016-12-21
To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients.
Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R
2016-01-01
AIM To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). METHODS VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. RESULTS Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. CONCLUSION Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients. PMID:28058017
[Importance of age and other risk factors in NSAID-induced gastropathy].
Lee, Hang Lak; Han, Dong Soo; Kim, Jin Bae; Kim, Jong Pyo; Jeon, Yong Chul; Sohn, Joo Hyun; Hahm, Joon Soo
2004-11-01
It is clinically important to analyze the risk factors of NSAID-induced gastropathy because there could be no symptoms. Age is the most important risk factor according to previous reports. The aim of this study was to find risk factors of NSAID-induced gastropathy and to confirm the association between NSAID-induced gastropathy and age. We retrospectively assessed 300 patients who conducted an upper gastroscopy during the course of chronic NSAID treatment. Median age of patients group is 51.4 +/- 12.2 years. In multivariate analysis, age and ulcer history are two significant risk factors. Median age is 46.7 +/- 10.7 years for the patients with nonspecific gastroscopic finding, 53.0 +/- 12.5 for those with erosion, 57.6 +/- 10.0 for those with ulcer, and 63.2 +/- 8.9 for those with hemorrhage. The proportion of ulcer patients is as follows: 6% in the patients of under 40 years old, 14.9% in patients of the 40s, 20% in patients of the 50s, 30.9% in patients of the 60s, 33.3% in patients over 70 years. The proportion of nonspecific findings is 62.2% in patients of the 40s, 37.8% in patients of the 50s, and 29% in patients over 60 years. Age is the most important risk factor of the NSAID-induced gastrointestinal mucosal injury. A larger randomized prospective control study will be required in the future for more conclusive results.
Chen, Liqi; Li, Guoli; Li, Jieshou; Fan, Chaogang; Xu, Jian; Wu, Bo; Liu, Kun; Zhang, Caihua
2013-04-01
To study the correlation between expression levels of ERCC1/TS mRNA and the susceptibility of preoperative chemotherapy for patients with gastric cancer. A total of forty cases with advanced gastric cancer of T3-4N1-2M0 were treated with preoperative chemotherapy according to FLEEOX regimen based on endarterial-intravenous coadministration. Sufficient, fresh gastric tissue specimens were obtained with the help of gastroscope, and the expression levels of ERCC1/TS mRNA were detected by qRT-PCR before chemotherapy. The chemotherapeutic response was evaluated with Choi Criteria after chemotherapy, and pathologic remission extent was observed after surgery. The correlation between the expression levels of ERCC1/TS mRNA before chemotherapy and the chemotherapeutic effect based on imageology and pathology was analyzed. The response rate of Chemotherapy in this cohort was 80.0 % based on imageology and 51.43 % based on pathology. The expression levels of ERCC1/TS mRNA were significantly associated with imageology remission extent (P = 0.033, P = 0.025) and pathologic remission extent (P = 0.044, P = 0.016), respectively. The chemotherapeutic effect on patients with low-expression levels of ERCC1/TS mRNA was better. From the perspective of pathology and imageology evaluating the preoperative chemotherapeutic response for patients with gastric cancer, ERCC1 and TS were used as the molecular predictors and provided prognostic information in this study.
Novel application of simultaneous multi-image display during complex robotic abdominal procedures
2014-01-01
Background The surgical robot offers the potential to integrate multiple views into the surgical console screen, and for the assistant’s monitors to provide real-time views of both fields of operation. This function has the potential to increase patient safety and surgical efficiency during an operation. Herein, we present a novel application of the multi-image display system for simultaneous visualization of endoscopic views during various complex robotic gastrointestinal operations. All operations were performed using the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) with the assistance of Tilepro, multi-input display software, during employment of the intraoperative scopes. Three robotic operations, left hepatectomy with intraoperative common bile duct exploration, low anterior resection, and radical distal subtotal gastrectomy with intracorporeal gastrojejunostomy, were performed by three different surgeons at a tertiary academic medical center. Results The three complex robotic abdominal operations were successfully completed without difficulty or intraoperative complications. The use of the Tilepro to simultaneously visualize the images from the colonoscope, gastroscope, and choledochoscope made it possible to perform additional intraoperative endoscopic procedures without extra monitors or interference with the operations. Conclusion We present a novel use of the multi-input display program on the da Vinci Surgical System to facilitate the performance of intraoperative endoscopies during complex robotic operations. Our study offers another potentially beneficial application of the robotic surgery platform toward integration and simplification of combining additional procedures with complex minimally invasive operations. PMID:24628761
Positive predictive value of peptic ulcer diagnosis codes in the Danish National Patient Registry
Viborg, Søren; Søgaard, Kirstine Kobberøe; Jepsen, Peter
2017-01-01
Background Diagnoses of peptic ulcer are registered in the Danish National Patient Registry (DNPR) for administrative as well as research purposes, but it is unknown whether the coding validity depends on the location of the ulcer. Objective To validate the International Classification of Diseases, 10th revision diagnosis codes of peptic ulcer in the DNPR by estimating positive predictive values (PPVs) for gastric and duodenal ulcer diagnoses. Methods We identified all patients registered with a hospital discharge diagnosis of peptic ulcer from Aarhus University Hospital, Denmark, in 1995–2006. Among them, we randomly selected 200 who had an outpatient gastroscopy at the time of ulcer diagnosis. We reviewed the findings from these gastroscopies to confirm the presence of peptic ulcer and its location. We calculated PPVs and corresponding 95% confidence intervals (CIs) of gastric and duodenal ulcer diagnoses, using descriptions from the gastroscopic examinations as standard reference. Results In total, 182 records (91%) were available for review. The overall PPV of peptic ulcer diagnoses in DNPR was 95.6% (95% CI 91.5–98.1), with PPVs of 90.3% (95% CI 82.4–95.5) for gastric ulcer diagnoses, and 94.4% (95% CI 87.4–98.2) for duodenal ulcer diagnoses. PPVs were constant over time. Conclusion The PPV of uncomplicated peptic ulcer diagnoses in the DNPR is high, and the location of the ulcers is registered correctly in most cases, indicating that the diagnoses are useful for research purposes. PMID:28503076
Positive predictive value of peptic ulcer diagnosis codes in the Danish National Patient Registry.
Viborg, Søren; Søgaard, Kirstine Kobberøe; Jepsen, Peter
2017-01-01
Diagnoses of peptic ulcer are registered in the Danish National Patient Registry (DNPR) for administrative as well as research purposes, but it is unknown whether the coding validity depends on the location of the ulcer. To validate the International Classification of Diseases, 10 th revision diagnosis codes of peptic ulcer in the DNPR by estimating positive predictive values (PPVs) for gastric and duodenal ulcer diagnoses. We identified all patients registered with a hospital discharge diagnosis of peptic ulcer from Aarhus University Hospital, Denmark, in 1995-2006. Among them, we randomly selected 200 who had an outpatient gastroscopy at the time of ulcer diagnosis. We reviewed the findings from these gastroscopies to confirm the presence of peptic ulcer and its location. We calculated PPVs and corresponding 95% confidence intervals (CIs) of gastric and duodenal ulcer diagnoses, using descriptions from the gastroscopic examinations as standard reference. In total, 182 records (91%) were available for review. The overall PPV of peptic ulcer diagnoses in DNPR was 95.6% (95% CI 91.5-98.1), with PPVs of 90.3% (95% CI 82.4-95.5) for gastric ulcer diagnoses, and 94.4% (95% CI 87.4-98.2) for duodenal ulcer diagnoses. PPVs were constant over time. The PPV of uncomplicated peptic ulcer diagnoses in the DNPR is high, and the location of the ulcers is registered correctly in most cases, indicating that the diagnoses are useful for research purposes.
An infrared spectroscopy method to detect ammonia in gastric juice.
Giovannozzi, Andrea M; Pennecchi, Francesca; Muller, Paul; Balma Tivola, Paolo; Roncari, Silvia; Rossi, Andrea M
2015-11-01
Ammonia in gastric juice is considered a potential biomarker for Helicobacter pylori infection and as a factor contributing to gastric mucosal injury. High ammonia concentrations are also found in patients with chronic renal failure, peptic ulcer disease, and chronic gastritis. Rapid and specific methods for ammonia detection are urgently required by the medical community. Here we present a method to detect ammonia directly in gastric juice based on Fourier transform infrared spectroscopy. The ammonia dissolved in biological liquid samples as ammonium ion was released in air as a gas by the shifting of the pH equilibrium of the ammonium/ammonia reaction and was detected in line by a Fourier transform infrared spectroscopy system equipped with a gas cell for the quantification. The method developed provided high sensitivity and selectivity in ammonia detection both in pure standard solutions and in a simulated gastric juice matrix over the range of diagnostic concentrations tested. Preliminary analyses were also performed on real gastric juice samples from patients with gastric mucosal injury and with symptoms of H. pylori infection, and the results were in agreement with the clinicopathology information. The whole analysis, performed in less than 10 min, can be directly applied on the sample without extraction procedures and it ensures high specificity of detection because of the ammonia fingerprint absorption bands in the infrared spectrum. This method could be easily used with endoscopy instrumentation to provide information in real time and would enable the endoscopist to improve and integrate gastroscopic examinations.
Huynh, Dep K; Toscano, Leanne; Phan, Vinh-An; Ow, Tsai-Wing; Schoeman, Mark; Nguyen, Nam Q
2017-06-01
This study aims to evaluate the role of unsedated, ultrathin disposable gastroscopy (TDG) against conventional gastroscopy (CG) in the screening and surveillance of gastroesophageal varices (GEVs) in patients with liver cirrhosis. Forty-eight patients (56.4 ± 1.3 years; 38 male, 10 female) with liver cirrhosis referred for screening (n = 12) or surveillance (n = 36) of GEVs were prospectively enrolled. Unsedated gastroscopy was initially performed with TDG, followed by CG with conscious sedation. The 2 gastroscopies were performed by different endoscopists blinded to the results of the previous examination. Video recordings of both gastroscopies were validated by an independent investigator in a random, blinded fashion. Endpoints were accuracy and interobserver agreement of detecting GEVs, safety, and potential cost saving. CG identified GEVs in 26 (54%) patients, 10 of whom (21%) had high-risk esophageal varices (HREV). Compared with CG, TDG had an accuracy of 92% for the detection of all GEVs, which increased to 100% for high-risk GEVs. The interobserver agreement for detecting all GEVs on TDG was 88% (κ = 0.74). This increased to 94% (κ = 0.82) for high-risk GEVs. There were no serious adverse events. Unsedated TDG is safe and has high diagnostic accuracy and interobserver reliability for the detection of GEVs. The use of clinic-based TDG would allow immediate determination of a follow-up plan, making it attractive for variceal screening and surveillance programs. (Clinical trial (ANZCTR) registration number: ACTRN12616001103459.). Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Comparison of aloe vera and omeprazole in the treatment of equine gastric ulcer syndrome.
Bush, J; van den Boom, R; Franklin, S
2018-01-01
Anecdotally, aloe vera is used to treat gastric ulceration, although no studies have yet investigated its efficacy in horses. To test the hypothesis that aloe vera would be noninferior to omeprazole in the treatment of equine gastric ulcer syndrome. Randomised, blinded clinical trial. Forty horses with grade ≥2 lesions of the squamous and/or glandular mucosa were randomly assigned to one of two groups. Horses received either aloe vera inner leaf gel (17.6 mg/kg bwt) b.i.d. or omeprazole (4 mg/kg bwt) s.i.d. for approximately 28 days, after which a repeat gastroscopic examination was performed to determine disease resolution. Horses with persistent lesions were offered a further 28 days of treatment with omeprazole (4 mg/kg bwt s.i.d.) and were re-examined on completion of treatment. Efficacy analyses were based on 39 horses that completed the trial. Equine squamous gastric disease (ESGD) was observed in 38 horses; improvement and healing rates in these horses were 56% and 17%, respectively, in the aloe vera group, and 85% and 75%, respectively, in the omeprazole group. Healing was less likely to occur in horses with prolonged gastric emptying. Equine glandular gastric disease (EGGD) was less common than ESGD (n = 14) and numbers were too small to perform meaningful statistical analyses. The hypothesis that aloe vera would be noninferior to omeprazole was not supported. No placebo control group was included. Limited numbers preclude any comment on the efficacy of aloe vera in the treatment of EGGD. Treatment with aloe vera was inferior to treatment with omeprazole. © 2017 EVJ Ltd.
Huxford, K E; Dart, A J; Perkins, N R; Bell, R; Jeffcott, L B
2017-11-01
AIMS To compare the efficacy of an enteric coated esomeprazole paste with an enteric coated omeprazole paste to increase gastric pH after oral administration in horses. METHODS Nine adult Standardbred horses were randomly assigned to three groups, each containing three horses, for a study comprising three phases of 10 days, with an 18-day washout period between each phase. In each phase, three horses received either 0.5 mg/kg esomeprazole, 1 mg/kg omeprazole or a placebo, as an oral paste, once daily for 10 days (Days 0-9). Over the course of study all horses received all three treatments. Gastric fluid samples were collected using a gastroscope on Days 1, 3, 5, 8 and 10, with food and water withheld for 16 hours prior to collection of samples. The pH of all samples was measured immediately after collection. RESULTS Mean pH (3.38; SD 1.75) of the gastric fluid samples in the horses that received the placebo was lower than in the horses that received esomeprazole (6.28; SD 1.75) or omeprazole (6.13; SD 1.75) (p<0.001). There was no difference in the mean pH between horses receiving esomeprazole and those receiving omeprazole (p=0.56). CONCLUSIONS AND CLINICAL RELEVANCE Under these study conditions, esomeprazole paste was equally as effective as omeprazole paste in increasing gastric pH in horses. Enteric coated esomeprazole, may be a therapeutic alternative to omeprazole for the prevention of gastric ulcers in horses.
Monitoring of endoscope reprocessing with an adenosine triphosphate (ATP) bioluminescence method.
Parohl, Nina; Stiefenhöfer, Doris; Heiligtag, Sabine; Reuter, Henning; Dopadlik, Dana; Mosel, Frank; Gerken, Guido; Dechêne, Alexander; Heintschel von Heinegg, Evelyn; Jochum, Christoph; Buer, Jan; Popp, Walter
2017-01-01
Background: The arising challenges over endoscope reprocessing quality proposes to look for possibilities to measure and control the process of endoscope reprocessing. Aim: The goal of this study was to evaluate the feasibility of monitoring endoscope reprocessing with an adenosine triphosphate (ATP) based bioluminescence system. Methods: 60 samples of eight gastroscopes have been assessed from routine clinical use in a major university hospital in Germany. Endoscopes have been assessed with an ATP system and microbial cultures at different timepoints during the reprocessing. Findings: After the bedside flush the mean ATP level in relative light units (RLU) was 19,437 RLU, after the manual cleaning 667 RLU and after the automated endoscope reprocessor (AER) 227 RLU. After the manual cleaning the mean total viable count (TVC) per endoscope was 15.3 CFU/10 ml, and after the AER 5.7 CFU/10 ml. Our results show that there are reprocessing cycles which are not able to clean a patient used endoscope. Conclusion: Our data suggest that monitoring of flexible endoscope with ATP can identify a number of different influence factors, like the endoscope condition and the endoscopic procedure, or especially the quality of the bedside flush and manual cleaning before the AER. More process control is one option to identify and improve influence factors to finally increase the overall reprocessing quality, best of all by different methods. ATP measurement seems to be a valid technique that allows an immediate repeat of the manual cleaning if the ATP results after manual cleaning exceed the established cutoff of 200 RLU.
Effects of deracoxib or buffered aspirin on the gastric mucosa of healthy dogs.
Sennello, Kathleen A; Leib, Michael S
2006-01-01
Use of cyclo-oxygenase-2 specific nonsteroidal anti-inflammatory drugs such as deracoxib has been advocated because of their anti-inflammatory actions and apparently low incidence of gastrointestinal adverse effects. Deracoxib will cause less endoscopically detectable gastric injury in dogs than aspirin, a nonselective nonsteroidal anti-inflammatory drug. Twenty-four random source healthy dogs. A randomized, placebo-controlled trial compared gastroscopic findings of dogs receiving placebo (q8h), aspirin (25 mg/kg PO q8h), or deracoxib (1.5 mg/kg QD, placebo ql2h) for 28 days. Gastroscopy on days -7, 6, 14, and 28 evaluated 4 regions of the stomach separately and visible lesions were scored. Dogs were observed every 8 hours for vomiting and diarrhea. Median total scores for each group were compared each day of endoscopic examination and total dog-days of vomiting and diarrhea were compared. Significance was determined at P < .05. There were significant differences in total scores of the aspirin group and both the placebo and deracoxib groups on days 6, 14, and 28. No significant differences in total scores were found between placebo and deracoxib on days 6, 14, and 28. Significant differences in dog-days of vomiting were found between the aspirin and deracoxib groups whereas no significant differences were found between the deracoxib and placebo groups. There was no detectable effect of treatment on dog-days of diarrhea. Administration of deracoxib to healthy dogs resulted in significantly lower gastric lesion scores, and fewer days of vomiting compared to aspirin, indicating that deracoxib is better tolerated than aspirin in some dogs.
Hyder, Q; Zahid, M A; Ahmad, W; Rashid, R; Hadi, S F; Qazi, S; Haider, H K H
2008-12-01
We present the first transgastric peritoneoscopy in a 20-year-old man. The objectives were to evaluate the impact of the site of viscerotomy on the technical feasibility of natural orifice transluminal endoscopic surgery (NOTES), assess transgastric peritoneoscopy as a complementary procedure, determine the safety and efficacy of NOTES, and attempt inspection/biopsy of the gallbladder. The patient was admitted with a benign gastric outlet obstruction, chronic cholecystitis and radiological suspicion of a mass in the gallbladder which was not visualised on diagnostic laparoscopy. Complementary transgastric peritoneoscopy was performed to gain deeper penetration of the tumour with the flexible tip of the gastroscope. The visceral "aperture" was created in the antrum where gastrojejunal anastomosis would be fashioned. Laparoscopic transillumination of the anterior gastric wall facilitated this part of the procedure. During transgastric peritoneoscopy, the gallbladder and structures in the upper and left hemi-abdomen appeared retrograde due to the unusual location of the gastrotomy. The right hemi-abdomen and pelvis were easily examined with a "straight shaft" approach. The gallbladder could not be identified with exploratory laparoscopy and transgastric peritoneoscopy. Due to risk of visceral injury, open gastrojejunal anastomosis and cholecystectomy were performed. Intraoperatively, an inflamed, thick-walled gallbladder was found adherent to the proximal duodenum. Transgastric peritoneoscopy was safely performed in our patient. The postoperative course was uneventful. Our patient showed significant improvement at 13 weeks after surgery without any procedure-related complication. In conclusion, transgastric peritoneoscopy may be used to complement diagnostic laparoscopy. Laparoscopic assistance during transluminal access facilitates simple tasks inside the peritoneal cavity to be performed safely.
Rey, Jean-Francois; Ogata, Haruhiko; Hosoe, Naoki; Ohtsuka, Kazuo; Ogata, Noriyuki; Ikeda, Keiichi; Aihara, Hiroyuki; Pangtay, Ileana; Hibi, Toshifumi; Kudo, Shin-ei; Tajiri, Hisao
2012-02-01
Passive video capsule endoscopy is the criterion standard for small-bowel exploration but cannot be used for the large gastric cavity. We report the first blinded comparative clinical trial in humans comparing a magnetically guided capsule endoscope (MGCE) and a conventional high-definition gastroscope. To assess the potential of gastric examination with a guided capsule. Blinded, nonrandomized comparative study. Single endoscopy center. The trial involved 61 patients included in a blinded capsule and gastroscopy comparative study. MGCE examination was performed 24 hours after patients had undergone gastroscopy. To remove food residue or mucus, patients drank 900 mL of water in 2 portions. Then to provide the air-water interface required by the guidance system, they drank 400 mL of water at 35°C. Visualization of the gastric pylorus, antrum, body, fundus, and cardia was evaluated as complete in 88.5%, 86.9%, 93.4%, 85.2%, and 88.5% of patients, respectively. Of gastric lesions, 58.3% were detected by both gastroscopy and MGCE at immediate assessment and review of recorded data. Capsule examination missed 14 findings and gastroscopy missed 31 findings seen with MGCE. Overall diagnostic yield was similar for both modalities. Pilot study. Diagnostic results were similar for the 2 methods. After some technical difficulties related to gastric expansion or presence of mucus had been overcome, this study opened a new field for noninvasive gastric examination in countries where high gastric cancer incidence demands a screening tool. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Swain, Paul; Toor, Arifa; Volke, Frank; Keller, Jutta; Gerber, Jeremy; Rabinovitz, Elisha; Rothstein, Richard I
2010-06-01
Remote manipulation of wireless capsule endoscopes might improve diagnostic accuracy and facilitate therapy. To test a new capsule-manipulation system. University hospital. A first-in-human study tested a new magnetic maneuverable wireless capsule in a volunteer. A wireless capsule endoscope was modified to include neodymium-iron-boron magnets. The capsule's magnetic switch was replaced with a thermal one and turned on by placing it in hot water. One imager was removed from the PillCam colon-based capsule, and the available space was used to house the magnets. A handheld external magnet was used to manipulate this capsule in the esophagus and stomach. The capsule was initiated by placing it in a microg of hot water. The capsule was swallowed and observed in the esophagus and stomach by using a gastroscope. Capsule images were viewed on a real-time viewer. The capsule was manipulated in the esophagus for 10 minutes. It was easy to make the capsule turn somersaults and to angulate at the cardioesophageal junction. In the stomach, it was easy to move the capsule back from the pylorus to the cardioesophageal junction and hold/spin the capsule at any position in the stomach. The capsule in the esophagus and stomach did not cause discomfort. Magnetic force varies with the fourth power of distance. This study suggests that remote manipulation of a capsule in the esophagus and stomach of a human is feasible and might enhance diagnostic endoscopy as well as enable therapeutic wireless capsule endoscopy. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Dîrnu, Rodica; Secureanu, F A; Neamţu, Carmen; Totolici, B D; Pop, O T; Mitruţ, P; Mălăescu, D Gh; Mogoantă, L
2012-01-01
Chronic gastritis has a high incidence in adults, causing progressive destruction of glandular structures, favoring the development of gastric atrophy. The association of chronic gastritis with intestinal type metaplasia of gastric mucosa has a poor outcome as intestinal metaplasia is regarded as a precancerous lesion. Metaplasia is common in patients with Helicobacter pylori infection and also heavy smokers. The aim of our study was to evaluate the relationship between chronic gastritis and intestinal metaplasia. The study was conducted on a total of 1218 patients, aged between 5 and 90 years, who presented for dyspeptic disorders in the period 2007-2010 and were examined clinically and endoscopically. During the gastroscopic examination, fragments of gastric mucosa were collected for the histopathological study and for highlighting the H. pylori infection. For the histopathological study, the Hematoxylin-Eosin and PAS-Alcian Blue stains were performed, while for the immunohistochemical study the anti-TAG72 and anti-PCNA antibodies were used. A diagnosis of gastritis was established in 615 patients, representing approximately 50.5% of all cases. Most cases with gastritis were found in people of middle age. Gastritis was present in almost all age groups, from teenagers to the elders. Of the 615 cases of gastritis, urease test was positive in 353 patients, representing approximately 57.40% of all patients with gastritis. Histopathological examination identified the presence of intestinal metaplasia in 61.60% of patients with chronic gastritis, mostly complete metaplasia. PCNA immunohistochemistry revealed that cell proliferation processes are intensified in intestinal metaplasia. This study highlights the importance of chronic gastritis, intestinal metaplasia, and H. pylori infection in the etiopathogeny of gastric cancer.
Scheidegger, M D; Gerber, V; Bruckmaier, R M; van der Kolk, J H; Burger, D; Ramseyer, A
2017-10-01
This study tested the hypothesis that adrenocortical function would be altered in horses with equine gastric ulcer syndrome (EGUS). Twenty-six sport horses competing at national or international levels in eventing (n=15) or endurance (n=11) were subjected to a gastroscopic examination and an adrenocorticotropic hormone (ACTH) stimulation test. Salivary cortisol concentrations were measured before (baseline) and after (30, 60, 90, 120 and 150min) IV ACTH injection (1μg/kg bodyweight). Within EGUS, two distinct diseases, equine squamous gastric disease (ESGD) and equine glandular gastric disease (EGGD), can be distinguished. ESGD was diagnosed in 8/11 (73%; 95% confidence intervals [95%CI], 43-92%) endurance horses and 5/15 (33%; 95% CI, 14-58%) eventing horses. EGGD was observed in 9/11 (82%; 95% CI, 53-96%) endurance horses and 9/15 (60%; 95% CI, 35-81%) eventing horses. The presence or severity of ESGD was unrelated to the presence or severity of EGGD. ACTH stimulation induced a larger increase in cortisol concentration in horses with moderate EGGD than in horses with mild EGGD. Cortisol concentration during the entire sampling period (total increase in cortisol concentration during the entire sampling period [dAUC], 31.1±6.4ng/mL) and the highest measured concentration at a single time point (maximal increase in cortisol concentration [dMAX], 10.3±2.3ng/mL) were increased (P=0.005 and P=0.038, respectively), indicating that horses with glandular gastric disease exhibited increased adrenocortical responses to ACTH stimulation. These results suggest that EGGD might be associated with an enhanced adrenocortical sensitivity. Further investigations are warranted to confirm the association between adrenocortical sensitivity and EGGD and to elucidate the pathophysiological mechanisms involved. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hoya, Yoshiyuki; Taki, Tetsuya; Watanabe, Atsushi; Nakayoshi, Tomoko; Okamoto, Tomoyoshi; Mitsumori, Norio; Yanaga, Katsuhiko
2016-04-01
We have reported the short-term results of pylorus reconstruction gastrectomy (PRG) that prevents duodenogastric reflux (DGR) and remnant gastritis after distal gastrectomy. We herein report the long-term results of the PRG. PRG was performed in 37 patients (age 31 to 86 [mean 67.8 ± 12.3] years, male:female = 22:15) with gastric cancer from June 2006 through December 2013. We examined the long-term outcome in 28 patients (age 41 to 86 [mean 67.0 ± 10.7] years, male:female = 18:10) that passed over 3 years after surgery (LTR 44.1 ± 11.7 months), and compared with their short-term result after the operation (STR 13.1 ± 6.9 months). The adverse events of gastric surgery evaluated in this study consisted of the degree of remnant gastritis, the presence of dumping syndrome, and degree of weight loss (%). There was no difference in the degree of DGR and remnant gastritis by gastroscopic finding between LTR and STR after PRG (P = 0.21). Statistically, there was no difference in the bile acid concentration of remnant gastric juice between LTR and STR (108.4 ± 254.1 vs. 94.0 ± 208.6 μmol/L, P = 0.33), and weight loss of LTR was the same as that of STR (5.67 ± 7.08 vs. 4.59 ± 5.63%, P = 0.34). There were few morphological changes in the reconstructed pylorus by the long-term course, but 2 patients showed mild atrophy. The form of reconstructed pylorus and the effect that reduces side effects of Billroth I seem to last for a long time.
Zhang, Z; Ai, B; Liao, Y; Liu, L; Liu, M
2016-11-01
The treatment of choice for leiomyoma, the most common benign esophageal tumor, is thoracoscopic enucleation. One of the most difficult aspects of thoracoscopic enucleation is the precise localization of small tumors (≤1.5 cm) and tumors without external protrusion. No simple, feasible solutions to this problem are available. We developed a novel methylene blue staining technique to localize small esophageal leiomyomas and evaluated the feasibility of our technique. Between January 2013 and July 2014, eight patients with small esophageal leiomyomas (≤1.5 cm) underwent thoracoscopic enucleation in Tongji Hospital. Preoperative endoscopic ultrasonography was performed in all patients. The leiomyomas were located in the middle (n = 5) and lower (n = 3) thirds of the esophagus. We preoperatively injected 0.5-1.0 mL methylene blue in the submucosa adjacent to the tumors under standard gastroscope guidance. The entire staining process took about 10 minutes. Staining was successful in all patients. The unstained tumor was exposed after the blue-stained mediastinal pleura, and overlying muscle were incised longitudinally. All procedures were successfully completed without conversion to open surgery. No abnormalities were detected in the esophageal mucosa. The median operating time was 60 minutes (range, 40-90 minutes). Postoperative histopathology confirmed leiomyoma in all patients. The median postoperative hospital stay was 6 days (range, 5-7 days). No major complications, such as esophageal leakage or esophageal diverticulum, occurred. Endoscopic methylene blue staining is safe and feasible for localizing small esophageal leiomyomas during thoracoscopic enucleation. This method will enable precise and easy enucleation. © 2015 International Society for Diseases of the Esophagus.
Tringali, Andrea; Lemmers, Arnaud; Meves, Volker; Terheggen, Grischa; Pohl, Jürgen; Manfredi, Guido; Häfner, Michael; Costamagna, Guido; Devière, Jacques; Neuhaus, Horst; Caillol, Fabrice; Giovannini, Marc; Hassan, Cesare; Dumonceau, Jean-Marc
2015-08-01
This technology review expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) on the available techniques for intraductal biliopancreatic imaging. The three cholangioscopy techniques are described: the "dual-operator" and " single-operator" mother-baby approaches using dedicated instruments, and the "direct" technique using currently available ultrathin gastroscopes. The mother-baby method is standardized and reproducible, while direct cholangioscopy is technically demanding and its safety requires further evaluation. As well as direct visualization of the bile ducts, cholangioscopy has the further advantage of allowing targeted biopsy. Image quality is still suboptimal for single-operator cholangioscopy, while the other techniques have achieved adequately detailed imaging. The costs of mother-baby cholangioscopy are high and its application in clinical practice should be restricted to selected cases (i.e. indeterminate biliary strictures/intraluminal lesions, difficult biliary stones) and to the setting of tertiary care centers. Peroral pancreatoscopy may find an indication in situations where other imaging modalities (mainly EUS) are inconclusive (i.e. delineation of main duct intraductal papillary mucinous neoplasia extension, sampling of indeterminate main pancreatic duct strictures). Intraductal ultrasonography (IDUS) has a poorer performance than EUS in the staging of pancreatic malignancies and can increase the risk of pancreatitis. A promising indication for IDUS could be the evaluation of indeterminate biliary strictures and ampullary tumors. Probe-based confocal laser endomicroscopy (pCLE) of the bile ducts is a difficult and expensive technique. Appropriate training needs to be established, since interpretation of images is challenging. pCLE can be an important diagnostic tool in the setting of indeterminate biliary strictures. © Georg Thieme Verlag KG Stuttgart · New York.
You, W C; Zhang, L; Gail, M H; Ma, J L; Chang, Y S; Blot, W J; Li, J Y; Zhao, C L; Liu, W D; Li, H Q; Hu, Y R; Bravo, J C; Correa, P; Xu, G W; Fraumeni, J F
1998-12-01
Cangshan County of Shandong Province has one of the lowest rates of gastric cancer (GC) in China. While intestinal metaplasia (IM) and dysplasia (DYS) are less common in Cangshan than in areas of Shandong at high risk of GC, these precursor lesions nevertheless affect about 20% of adults age > or = 55. In order to evaluate determinants of IM and DYS in Cangshan County, a low risk area of GC a survey was conducted among 214 adults who participated in a gastroscopic screening survey in Cangshan County in 1994. A dietary interview and measurement of serum Helicobacter pylori antibodies were performed. The prevalence of H. pylori was lowest (19%) among those with normal gastric mucosa, rising steadily to 35% for superficial gastritis (SG), 56% for chronic atrophic gastritis (CAG), 80% for IM, and 100% for DYS. The prevalence odds of precancerous lesions were compared with the odds of normal histology or SG. The odds ratio (OR) or CAG associated with H. pylori positivity was 4.2 (95% confidence interval [CI] : 1.7-10.0), while the OR of IM/DYS associated with H. pylori positivity was 31.5 (95% CI: 5.2-187). After adjusting for H. pylori infection, drinking alcohol was a risk factor for CAG (OR = 3.2, 95% CI: 1.1-9.2) and IM/DYS (OR = 7.8, 95% CI: 1.3-47.7). On the other hand, consumption of garlic showed non-significant protective effects and an inverse association with H. pylori infection. The findings of this study suggest that infection with H. pylori is a risk factor and garlic may be protective, in the development and progression of advanced precancerous gastric lesions in an area of China at relatively low risk of GC.
Endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy
Wang, Fei; Xu, Boming; Li, Quanpeng; Zhang, Xiuhua; Jiang, Guobing; Ge, Xianxiu; Nie, Junjie; Zhang, Xiuyun; Wu, Ping; Ji, Jie; Miao, Lin
2016-01-01
Abstract Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy is challenging. Results of ERCP in those patients varied. The aim of our study was to evaluate the safety and effectiveness of various endoscopes-assisted ERCP in patients with surgically altered anatomy. Fifty-two patients with Billroth II reconstruction (group A), 20 patients with subtotal or total gastrectomy with Roux-en-Y anastomosis (group B), 25 patients with pancreatoduodenectomy or Roux-en-Y hepaticojejunostomy reconstruction (group C) were included. Gastroscope, duodenoscope, colonoscope, and double-balloon enteroscope were used. The endoscope insertion success rate of groups A, B, C was 96.2% (50/52), 85.0% (17/20), 80% (20/25), respectively. χ2 test showed that there was no significant difference between the 3 groups (P = 0.068). The mean insertion time was 36.7, 68.4, and 84.0 minutes, respectively. One-way ANOVA showed that the insertion time of group C was significantly longer than that of groups B and C (both P <0.001). The endoscopic cannulation success rates of groups A, B, C were 90%, 82.4%, and 100%, respectively. χ2 test showed that there was no significant difference between the 3 groups (P = 0.144). The mean cannulation time was 19.4, 28.1, and 20.4 minutes, respectively. One-way ANOVA showed that the cannulation time of group B was longer than that of groups A and C (P <0.001, P = 0.001, respectively). In total, 74 patients with successful biliary cannulation achieved the therapeutic goal; thus, the clinical success rate was 76.3% (74/97). Our study showed that ERCP in patients with surgically altered anatomy was safe and feasible. PMID:28033284
Duc, D L; Ribiollet, A; Dode, X; Ducel, G; Marchetti, B; Calop, J
2001-06-01
In the light of more and more invasive procedures being carried out in digestive endoscopy using sterile devices, it appears necessary to put in place a process of endoscope reprocessing capable of ensuring the complete elimination of micro-organisms contaminating the device. We undertook a study of the microbial efficacy of STERIS SYSTEM 1 (SS1) which purports to achieve this objective. The channels of a gastroscope and a colonoscope were contaminated with suspensions of Pseudomonas aeruginosa, Aspergillus niger and Bacillus subtilis spores. Two procedures were then followed: (1) manual washing only, and (2) treatment in SS1 without prewashing. Recoveries of organisms were made from each channel according to a standard methodology to discover any survivors. Contamination controls we re assessed to measure the logarithmic reduction between the initial contamination and that recovered from the channels. Six cycles per micro-organisms, per type of endoscope, and per type of procedure were carried out. From an initial contamination leve l of 10(6) micro-organisms per endoscope, no micro-organisms were recovered in 35 of the 36 cycles with the SS1. In one cycle with the colonoscope, three B. subtilis organisms were recovered from the channels. Washing only gave microbial reductions which varied according to the micro-organism tested. The maximum reduction with washing alone was by a factor of 10(3 +/- 0.1)for B. subtilis and the minimum reduction factor was 10(3 +/- 0.3)for P. aeruginosa. Considering the results obtained with SS1 without prewashing and the efficacy obtained from washing only, the washing step offers an additional antimicrobial assurance reduction factor of between 10 and 103.1. This study shows that SS1, integrated into an overall reprocessing procedure for digestive endoscopes, is capable of delivering the complete elimination of contaminating micro-organisms in a reduced time and eliminates the toxic risk of reprocessing associated with aldehyde based disinfectants. Copyright 2001 The Hospital Infection Society.
Park, Joongwon; Kim, Mi Kyung; Park, Sill Moo
1995-01-01
Objectives: We conducted an analysis of correlation between histological grading of chronic gastritis and the presence of H. pylori infection to investigate if H. pylori influences histological severity of chronic gastritis in Korean patients with peptic ulcers. Methods: Gastroscopic antral biopsy specimens and peripheral venous blood were taken from 80 patients with gastric or duodenal ulcers. H. pylori was identified microscopically in sections with Giemsa staining and quantitative grading of cultured H. pylori was reported on a scale 0 to 3. The histopathological features of biopsy specimens were reported according to the Sydney classification of chronic gastritis. Serum gastritis and pepsinogen concentrations were measured by radioimmunoassay. Results: H. pylori was identified in 62.5% (20 of 32 GU, 30 of 48 DU) of the study group. Gastric clonization rate of H. pylori did not increased with age. Forty of 50 biopsy specimens with H. pylori and also 23 of 30 biopsy specimens without H. pylori showed active chronic gastritis. There was no significant correlation overall between the presence of H. pylori and histological grading of chronic gastritis, including activity, and also no association was found between the quantitative grading of H. pylori and the histological grading of chronic gastritis. With and without H. pylori, a mean of serum gastritis concentration (79.4±43.0 pg/ml and 80.2±31.9 pg/ml) showed no significant difference, but a mean of serum pepsinogen concentration (87.7±41.6 ng/ml and 119±34.4 ng/ml) showed significant difference between the populations with and without H. pylori (p=0.001) Conclusions: The influence of H. pylori on histological grading of chronic gastritis in Korean is less than that in prior studies of Western countries, and further investigation of pathogenesis of H. pylori in chronic gastritis and peptic ulceration is necessary. PMID:7495770
Rainsford, K D
1982-01-01
A critical analysis has been performed of reports published on the incidence of gastro-intestinal (GI) side-effects found in arthritic patients being treated with non-steroid anti-inflammatory (NSAI) drugs. The results show the following: 1. The incidence of GI ulceration (as revealed by gastroscopy) and haemorrhage in arthritic patients taking NSAI drugs may be higher than suspected from clinical trial data. 2. Incidence of all GI side-effects (including ulceration and haemorrhage) may be lower with some of the new NSAI drugs than with traditional drugs (e.g. aspirin, indomethacin and phenylbutazone). 3. Arthritic patients may be more susceptible to the ulcerogenic actions of NSAI drugs. Experiments with animals, together with evidence from clinical studies, indicate that stress factors and the presence of decreased mucosal resistance in the diseased state may contribute to the enhanced susceptibility of the GI tract towards the ulcerogenicity of NSAI drugs. 4. Comparison of data on gastroscopic observations in man with the author's data on the effects of NSAI drugs in stress-sensitized rats shows the latter technique appears to be a useful means of predicting the ulcerogenic potential of NSAI drugs in man. The comparison has also been used to predict the ulcerogenicity of drug - alcohol combinations; alcohol being a common ulcerogen consumed by many patients. Some NSAI drugs with low ulcerogenic activity (i.e. azapropazone, benoxaprofen and fenclofenac) in the stressed-rat assay show little or no interaction with alcohol. These studies using laboratory animals show the importance of employing conditions to mimic environmental factors (e.g. stress and alcohol consumption) which might predispose individuals to ulcerogenic or other side-effects of NSAI drugs. From these studies it appears possible to construct 'predictive profiles' of the relative ulcerogenicity of NSAI drugs which may be applicable to the clinical situation in man.
Liu, Ding-Yun; Gan, Tao; Rao, Ni-Ni; Xing, Yao-Wen; Zheng, Jie; Li, Sang; Luo, Cheng-Si; Zhou, Zhong-Jun; Wan, Yong-Li
2016-08-01
The gastrointestinal endoscopy in this study refers to conventional gastroscopy and wireless capsule endoscopy (WCE). Both of these techniques produce a large number of images in each diagnosis. The lesion detection done by hand from the images above is time consuming and inaccurate. This study designed a new computer-aided method to detect lesion images. We initially designed an algorithm named joint diagonalisation principal component analysis (JDPCA), in which there are no approximation, iteration or inverting procedures. Thus, JDPCA has a low computational complexity and is suitable for dimension reduction of the gastrointestinal endoscopic images. Then, a novel image feature extraction method was established through combining the algorithm of machine learning based on JDPCA and conventional feature extraction algorithm without learning. Finally, a new computer-aided method is proposed to identify the gastrointestinal endoscopic images containing lesions. The clinical data of gastroscopic images and WCE images containing the lesions of early upper digestive tract cancer and small intestinal bleeding, which consist of 1330 images from 291 patients totally, were used to confirm the validation of the proposed method. The experimental results shows that, for the detection of early oesophageal cancer images, early gastric cancer images and small intestinal bleeding images, the mean values of accuracy of the proposed method were 90.75%, 90.75% and 94.34%, with the standard deviations (SDs) of 0.0426, 0.0334 and 0.0235, respectively. The areas under the curves (AUCs) were 0.9471, 0.9532 and 0.9776, with the SDs of 0.0296, 0.0285 and 0.0172, respectively. Compared with the traditional related methods, our method showed a better performance. It may therefore provide worthwhile guidance for improving the efficiency and accuracy of gastrointestinal disease diagnosis and is a good prospect for clinical application. Copyright © 2016 Elsevier B.V. All rights reserved.
Till, H K-H; Muensterer, O; Keller, A; Körner, A; Blueher, S; Merkle, R; Kiess, W
2008-02-01
The European guidelines for bariatric surgery clearly define criteria for operating children with morbid obesity. However the appropriate technique for this age-group has not been identified yet. So far gastric banding and Roux-Y bypass represent the standards, but they demand life-long tolerance of either an artificial device or significant malabsorption. Although laparoscopic sleeve gastrectomy (LSG) demands neither, it has not been advocated for this age-group as a stand-alone technique. We report the outcome and the rationale for this approach in a 16-year-old girl with morbid obesity. The patient had been in an intensive weight loss programme for several years, but within the last 12 months her body weight had increased again dramatically. At referral she presented with a body mass index (BMI) of 43.1 kg/m(2) (height 169 cm, preoperative weight 121 kg) and suffered from co-morbidities as features of a developing metabolic-vascular syndrome such as dyslipidemia and arterial hypertension. Our obesity team and her parents opted for surgery at that time. The patient underwent LSG with a 5-trocar technique. With a gastroscope protecting the lesser curvature, the stomach was resected from the antrum to the fundus using an EndoGIA stapler. The operative time was 95 minutes, there were no perioperative complications and the patient was extubated immediately. An upper GI contrast study on postoperative day 4 showed a tubular gastric remnant with a volume of about 200 ml. The patient's diet was advanced as tolerated to full oral intake, and she was followed-up regularly in our special obesity outpatient clinic. After 12 months she had lost 36 kg (BMI 29 kg/m(2)) and enjoyed sports and activities with friends again. Laboratory studies ruled out malnutrition or vitamin deficiency. LSG is a safe and effective option for bariatric surgery in obese adolescents. It can be offered as a stand-alone restrictive operation and could be extended to a malabsorptive procedure at any time. However longer follow-up is required before universally recommending this procedure.
Wen, Lei
2017-08-20
Aspirin is widely used for the prevention of cardiovascular and cerebrovascular diseases for the past few years. However, much attention has been paid to the adverse effects associated with aspirin such as gastrointestinal bleeding. How to weigh the benefits and hazards? The current study aimed to assess the feasibility of a cardiovascular/gastrointestinal risk calculator, AsaRiskCalculator, in predicting gastrointestinal events in Chinese patients with myocardial infarction (MI), determining unique risk factor(s) for gastrointestinal events to be considered in the calculator. The MI patients who visited Shapingba District People's Hospital between January 2012 and January 2016 were retrospectively reviewed. Based on gastroscopic data, the patients were divided into two groups: gastrointestinal and nongastrointestinal groups. Demographic and clinical data of the patients were then retrieved for statistical analysis. Univariate and multiple logistic regression analyses were used to identify independent risk factors for gastrointestinal events. The receiver operating characteristic (ROC) curves were used to assess the predictive value of AsaRiskCalculator for gastrointestinal events. A total of 400 MI patients meeting the eligibility criteria were analyzed, including 94 and 306 in the gastrointestinal and nongastrointestinal groups, respectively. The data showed that age, male gender, predicted gastrointestinal events, and Helicobacter pylori (HP) infection were positively correlated with gastrointestinal events. In multiple logistic regression analysis, predicted gastrointestinal events and HP infection were identified as risk factors for actual gastrointestinal events. HP infection was highly predictive in Chinese patients; the ROC curve indicated an area under the curve of 0.822 (95% confidence interval: 0.774-0.870). The best diagnostic cutoff point of predicted gastrointestinal events was 68.0‰, yielding sensitivity and specificity of 60.6% and 93.1%, respectively, for predicting gastrointestinal events in Chinese patients with MI. AsaRiskCalculator had a predictive value for gastrointestinal events in Chinese patients with MI. HP infection seemed to be an independent risk factor for gastrointestinal events caused by long-term aspirin treatment in Chinese patients with MI, and it should be included in the risk calculator adapted for Chinese patients.
Mbithi, J N; Springthorpe, V S; Sattar, S A; Pacquette, M
1993-01-01
Baths with 2% alkaline glutaraldehyde are often reused for 14 days to decontaminate flexible fiberoptic endoscopes (FFEs) between patients, but the effect of such reuse on the disinfectant's activity has not been known. Many busy endoscopy units also disinfect FFEs with contact times shorter than those recommended by the disinfectant manufacturer. We therefore collected samples of the disinfectant over the 14-day reuse period from two manual and one automatic bath used for bronchoscopes and gastroscopes at a local hospital. Control samples were also collected from a manual bath of 2% alkaline glutaraldehyde which did not receive any endoscopes. The germicidal activities of the samples were assessed in a carrier test against a mixture of hepatitis A virus, poliovirus 1 (Sabin), and Pseudomonas aeruginosa; the mixture also contained either Mycobacterium bovis or Mycobacterium gordonae. Bovine serum (5%) was the organic load. The criterion of efficacy was a minimum of a 3-log10-unit reduction in the infectivity titers of the organisms tested. The initial disinfectant concentration in all the baths was nearly 2.25%; it became about 1.8% in the control bath and fell to approximately 1% in the three test baths after 14 days. No protein was detected in the control bath, while its concentration rose gradually in the test baths to a maximum of 1,267 micrograms/ml after 14 days. With a contact time of 10 min at 20 +/- 2 degrees C, all the samples from the control bath were effective against all the test organisms and all the samples from all the test baths were also effective against P. aeruginosa. With a contact time of 10 or 20 min at 20+/-2 degrees C, the virucidal and mycobactericidal activities of the samples from the test baths showed broad-spectrum germicidal activity when the contact time was increased to 45 min and the temperature was raised to 25 degrees C. These findings emphasize the care needed in the disinfection of FFEs, especially in view of the increasing threat of AIDS and the resurgence of tuberculosis. PMID:8263184
Coates, D
2001-05-01
Microbiological tests were carried out to evaluate a new chlorine dioxide sterilant: Tristel OneShot. Preliminary in vitro suspension tests showed that solutions containing around 140 ppm chlorine dioxide achieved a reduction factor exceeding 10(6) of Staphylococcus aureus in 1min and of Bacillus subtilis spores in 2.5 min in the presence of 3g/L bovine albumin. Subsequent tests evaluated the effectiveness of Tristel One-Shot in a Medivator washer/disinfector fitted with a Tristel Generator for processing flexible endoscopes. Each test run involved three stages. In the first, the instrument and air-water channels of a gastroscope were inoculated with a suspension of Pseudomonas aeruginosa (10(8)cfu/ml) in 10% sodium glutamate and serum (0, 5 or 10%) and then drained, partially dried, and saline flushed through for total viable counts (TVCs). In the second stage, the channels were re-inoculated with test organisms; detergent was flushed through the channels which were then brushed; and saline was flushed through for TVCs. In the third stage, the channels were re-inoculated; detergent was flushed through the channels which were then brushed; the endoscope was processed in the Medivator; and saline was flushed through for TVCs. Carrying out all three stages enabled determination of (1) the contribution played by manual cleaning of channels prior to processing in the Medivator, and (2) the combined effect of manual cleaning followed by processing. Two series of test runs were done. In the first, the Tristel Generator was set to generate 230ppm chlorine dioxide, and in the second 150ppm. In the first, cleaning followed by processing in the Medivator consistently achieved a >/= 10(6)-fold reduction of test organisms, and in the second a >/= 10(5)-fold reduction. Pre-cleaning of channels was very important-when done the initial concentration of serum in the inoculum (0-10%) had no affect on the results obtained after processing. Copyright 2001 The Hospital infection Society.
Huff, N K; Auer, A D; Garza, F; Keowen, M L; Kearney, M T; McMullin, R B; Andrews, F M
2012-01-01
Sea buckthorn berries (Hippophae rhamnoides) are rich in vitamin C and E, carotenoids, flavonoids, fatty acids, plant sterols, lignans, and minerals. A feed supplement containing sea buckthorn berries might have efficacy in treatment and prevention of gastric ulcers in horses. To test the efficacy of a commercially available formulation of sea buckthorn berries and pulp (SeaBuck SBT Gastro-Plus) for treatment and prevention of gastric ulcers in stall-confined horses. Eight Thoroughbred and Thoroughbred-cross horses (3-10 years of age, 5 geldings and 3 mares, 380-600 kg body weight). This study was a 2-period crossover in which all horses received no treatment (untreated controls; n = 8) and treatment (SeaBuckSBT Gastro-Plus, 4 ounces [35.6 g berries and pulp], twice daily; n = 8) mixed with a pelleted complete feed (18% crude fiber; 9% starch; 14% crude protein). Horses were treated for 4 weeks followed by a 1-week (d28-d35) alternating feed-deprivation period to induce or worsen existing ulcers. Gastroscopic examinations were performed on days 0, 28, and 35. Gastric juice pH was measured and gastric ulcer number and severity scores were assigned by a masked investigator. Mean nonglandular gastric ulcer scores significantly (P < .05) increased in all horses after day 28, as a result of intermittent feed deprivation. Mean nonglandular gastric ulcer number (P = .84) and severity (P = .51) were not significantly different between SBT-treated and untreated control horses. However, mean glandular ulcer number (P = .02) and glandular ulcer severity (P = .02) were significantly lower in the SBT-treated horses compared with the untreated control at week 5. SeaBuck SBT Gastro-Plus liquid fed to horses did not show efficacy in treatment or prevention of naturally occurring nonglandular ulcers in horses; however, glandular ulcer scores were significantly lower in SBT-treated horses after feed deprivation. Thus, SBT might have efficacy in prevention of glandular ulcers in horses housed in stalls and undergoing intermittent feeding. Copyright © 2012 by the American College of Veterinary Internal Medicine.
Incomplete colonoscopy: Maximizing completion rates of gastroenterologists
Brahmania, Mayur; Park, Jei; Svarta, Sigrid; Tong, Jessica; Kwok, Ricky; Enns, Robert
2012-01-01
BACKGROUND Cecal intubation is one of the goals of a quality colonoscopy; however, many factors increasing the risk of incomplete colonoscopy have been implicated. The implications of missed pathology and the demand on health care resources for return colonoscopies pose a conundrum to many physicians. The optimal course of action after incomplete colonoscopy is unclear. OBJECTIVES: To assess endoscopic completion rates of previously incomplete colonoscopies, the methods used to complete them and the factors that led to the previous incomplete procedure. METHODS: All patients who previously underwent incomplete colonoscopy (2005 to 2010) and were referred to St Paul’s Hospital (Vancouver, British Columbia) were evaluated. Colonoscopies were re-attempted by a single endoscopist. Patient charts were reviewed retrospectively. RESULTS: A total of 90 patients (29 males) with a mean (± SD) age of 58±13.2 years were included in the analysis. Thirty patients (33%) had their initial colonoscopy performed by a gastroenterologist. Indications for initial colonoscopy included surveillance or screening (23%), abdominal pain (15%), gastrointestinal bleeding (29%), change in bowel habits or constitutional symptoms (18%), anemia (7%) and chronic diarrhea (8%). Reasons for incomplete colonoscopy included poor preparation (11%), pain or inadequate sedation (16%), tortuous colon (30%), diverticular disease (6%), obstructing mass (6%) and stricturing disease (10%). Reasons for incomplete procedures in the remaining 21% of patients were not reported by the referring physician. Eighty-seven (97%) colonoscopies were subsequently completed in a single attempt at the institution. Seventy-six (84%) colonoscopies were performed using routine manoeuvres, patient positioning and a variable-stiffness colonoscope (either standard or pediatric). A standard 160 or 180 series Olympus gastroscope (Olympus, Japan) was used in five patients (6%) to navigate through sigmoid diverticular disease; a pediatric colonoscope was used in six patients (7%) for similar reasons. Repeat colonoscopy on the remaining three patients (3%) failed: all three required surgery for strictures (two had obstructing malignant masses and one had a severe benign obstructing sigmoid diverticular stricture). CONCLUSION: Most patients with previous incomplete colonoscopy can undergo a successful repeat colonoscopy at a tertiary care centre with instruments that are readily available to most gastroenterologists. Other modalities for evaluation of the colon should be deferred until a second attempt is made at an expert centre. PMID:22993727
2011-01-01
Background Reprocessing of endoscopes generally requires labour-intensive manual cleaning followed by high-level disinfection in an automated endoscope reprocessor (AER). EVOTECH Endoscope Cleaner and Reprocessor (ECR) is approved for fully automated cleaning and disinfection whereas AERs require manual cleaning prior to the high-level disinfection procedure. The purpose of this economic evaluation was to determine the cost-efficiency of the ECR versus AER methods of endoscopy reprocessing in an actual practice setting. Methods A time and motion study was conducted at a Canadian hospital to collect data on the personnel resources and consumable supplies costs associated with the use of EVOTECH ECR versus manual cleaning followed by AER with Medivators DSD-201. Reprocessing of all endoscopes was observed and timed for both reprocessor types over three days. Laboratory staff members were interviewed regarding the consumption and cost of all disposable supplies and equipment. Exact Wilcoxon rank sum test was used for assessing differences in total cycle reprocessing time. Results Endoscope reprocessing was significantly shorter with the ECR than with manual cleaning followed by AER. The differences in median time were 12.46 minutes per colonoscope (p < 0.0001), 6.31 minutes per gastroscope (p < 0.0001), and 5.66 minutes per bronchoscope (p = 0.0040). Almost 2 hours of direct labour time was saved daily with the ECR. The total per cycle cost of consumables and labour for maintenance was slightly higher for EVOTECH ECR versus manual cleaning followed by AER ($8.91 versus $8.31, respectively). Including the cost of direct labour time consumed in reprocessing scopes, the per cycle and annual costs of using the EVOTECH ECR was less than the cost of manual cleaning followed by AER disinfection ($11.50 versus $11.88). Conclusions The EVOTECH ECR was more efficient and less costly to use for the reprocessing of endoscopes than manual cleaning followed by AER disinfection. Although the cost of consumable supplies required to reprocess endoscopes with EVOTECH ECR was slightly higher, the value of the labour time saved with EVOTECH ECR more than offset the additional consumables cost. The increased efficiency with EVOTECH ECR could lead to even further cost-savings by shifting endoscopy laboratory personnel responsibilities but further study is required. PMID:21967345
Forte, Lindy; Shum, Cynthia
2011-10-03
Reprocessing of endoscopes generally requires labour-intensive manual cleaning followed by high-level disinfection in an automated endoscope reprocessor (AER). EVOTECH Endoscope Cleaner and Reprocessor (ECR) is approved for fully automated cleaning and disinfection whereas AERs require manual cleaning prior to the high-level disinfection procedure. The purpose of this economic evaluation was to determine the cost-efficiency of the ECR versus AER methods of endoscopy reprocessing in an actual practice setting. A time and motion study was conducted at a Canadian hospital to collect data on the personnel resources and consumable supplies costs associated with the use of EVOTECH ECR versus manual cleaning followed by AER with Medivators DSD-201. Reprocessing of all endoscopes was observed and timed for both reprocessor types over three days. Laboratory staff members were interviewed regarding the consumption and cost of all disposable supplies and equipment. Exact Wilcoxon rank sum test was used for assessing differences in total cycle reprocessing time. Endoscope reprocessing was significantly shorter with the ECR than with manual cleaning followed by AER. The differences in median time were 12.46 minutes per colonoscope (p < 0.0001), 6.31 minutes per gastroscope (p < 0.0001), and 5.66 minutes per bronchoscope (p = 0.0040). Almost 2 hours of direct labour time was saved daily with the ECR. The total per cycle cost of consumables and labour for maintenance was slightly higher for EVOTECH ECR versus manual cleaning followed by AER ($8.91 versus $8.31, respectively). Including the cost of direct labour time consumed in reprocessing scopes, the per cycle and annual costs of using the EVOTECH ECR was less than the cost of manual cleaning followed by AER disinfection ($11.50 versus $11.88). The EVOTECH ECR was more efficient and less costly to use for the reprocessing of endoscopes than manual cleaning followed by AER disinfection. Although the cost of consumable supplies required to reprocess endoscopes with EVOTECH ECR was slightly higher, the value of the labour time saved with EVOTECH ECR more than offset the additional consumables cost. The increased efficiency with EVOTECH ECR could lead to even further cost-savings by shifting endoscopy laboratory personnel responsibilities but further study is required.
Stray energy transfer during endoscopy.
Jones, Edward L; Madani, Amin; Overbey, Douglas M; Kiourti, Asimina; Bojja-Venkatakrishnan, Satheesh; Mikami, Dean J; Hazey, Jeffrey W; Arcomano, Todd R; Robinson, Thomas N
2017-10-01
Endoscopy is the standard tool for the evaluation and treatment of gastrointestinal disorders. While the risk of complication is low, the use of energy devices can increase complications by 100-fold. The mechanism of increased injury and presence of stray energy is unknown. The purpose of the study was to determine if stray energy transfer occurs during endoscopy and if so, to define strategies to minimize the risk of energy complications. A gastroscope was introduced into the stomach of an anesthetized pig. A monopolar generator delivered energy for 5 s to a snare without contacting tissue or the endoscope itself. The endoscope tip orientation, energy device type, power level, energy mode, and generator type were varied to mimic in vivo use. The primary outcome (stray current) was quantified as the change in tissue temperature (°C) from baseline at the tissue closest to the tip of the endoscope. Data were reported as mean ± standard deviation. Using the 60 W coag mode while changing the orientation of the endoscope tip, tissue temperature increased by 12.1 ± 3.5 °C nearest the camera lens (p < 0.001 vs. all others), 2.1 ± 0.8 °C nearest the light lens, and 1.7 ± 0.4 °C nearest the working channel. Measuring temperature at the camera lens, reducing power to 30 W (9.5 ± 0.8 °C) and 15 W (8.0 ± 0.8 °C) decreased stray energy transfer (p = 0.04 and p = 0.002, respectively) as did utilizing the low-voltage cut mode (6.6 ± 0.5 °C, p < 0.001). An impedance-monitoring generator significantly decreased the energy transfer compared to a standard generator (1.5 ± 3.5 °C vs. 9.5 ± 0.8 °C, p < 0.001). Stray energy is transferred within the endoscope during the activation of common energy devices. This could result in post-polypectomy syndrome, bleeding, or perforation outside of the endoscopist's view. Decreasing the power, utilizing low-voltage modes and/or an impedance-monitoring generator can decrease the risk of complication.
[Clinical analysis of intestinal lymphangiectasia in 47 children].
Guo, S; Song, L; Guan, D X; Mei, T L; Zhou, J; Yu, F H; Wang, G L; Zhang, J; Shen, H Q; Xu, X W
2017-12-02
Objective: To analyze the clinical manifestations, diagnosis, treatment and prognosis of intestinal lymphangiectasia (IL) in children in order to improve the skills of diagnosis and treatment of IL. Method: Clinical manifestations, laboratory findings, gastroscopic findings, histopathological examinations and lymphatic radionuclide imaging assessments were analyzed retrospectively among 47 IL patients who were hospitalized in the Gastroenterology Department of Beijing Children's Hospital Affiliated to Capital Medical University from June 2007 to December 2015. All patients were followed up by telephone. According to the various causes, the patients were divided into the primary intestinal lymphangiectasia (PIL) group and secondary IL group, and their clinical manifestations were compared by t test, Rank sum test or Chi-square test. Result: In 47 IL patients, there were 38 children (81%) younger than 3 years old. There were 43 PIL patients (91%) and 4 secondary IL patients (9%). Between PIL and secondary IL, there were statistical differences in serum albumin ( t=- 3.950, P< 0.005) , globulin( t=- 2.850, P= 0.007), age of onset( U =27.000, P= 0.024), age at diagnosis( U =29.000, P= 0.030) and course of disease( U =26.500, P= 0.023), whereas there were no statistical differences in lymphocyte count, IgG, lymphatic radionuclide imaging, histopathology and gender(all P> 0.05). Edema (44 cases, 94%), diarrhea (42 cases, 89%), accompanied with infection (35 cases, 74%) and ascites (30 cases, 64%) were the main clinical manifestations. In 47 IL patients, 45 patients were done gastroscopy and histopathological examinations, and there were 31 patients' histopathological examinations(69%) were positive. Forty patients were done lymphatic radionuclide imaging, and there was evidence of protein losing from gut via lymphatic radionuclide imaging in 39 patients(98%). Among 47 patients, 35 patients (74%) were followed up, 32 patients had good prognosis, 2 patient failed to show evidence of improvement, 1 patient died and no patient experienced a relapse till the end of the follow-up. In 35 patients, 28 patients were treated with medium chain triglycerides (MCT) dietary therapy, 26 patients showed improvement in symptoms, and 2 patients had no improvement. Among 35 patients with follow-up, there were 6 patients received surgical treatment, and their symptoms were improved. Conclusion: PIL are the majority of IL in children younger than 3 years old. The main clinical manifestations are edema, diarrhea, accompanied with infection and ascites. For the patients without the evidence of lymphangiectasia from duodenum histopathological examination, further consideration of lymphatic radionuclide imaging, clinical manifestations, and laboratory studies are needed to make a final diagnosis. MCT dietary therapy is the cornerstone of IL medical management.
[Effect of neoadjuvant chemotherapy on nutritional status of locally advanced gastric cancer].
Deng, Guopeng; Qu, Jianjun; Zhai, Shengyong; Shi, Yiran; Wang, Xinbo
2018-03-25
To study the effect of neoadjuvant chemotherapy on nutritional status in patients with locally advanced gastric cancer. Cases inclusion criteria: (1)18-65 years old; (2) Gastric cancer confirmed by gastroscopic biopsy; (3) Preoperative TNM stage III( according to the AJCC stage 2000 standard; (4) Kamosfsky functional status score> 60 points; (5)Receiving neoadjuvant chemotherapy voluntarily and signing the informed consent form. Case exclusion criteria: (1)Having contraindications of chemotherapy and surgery; (2) Suffering from heart, liver and kidney and other underlying diseases; (3) Concurrent with malignant diseases, wasting disease or other digestive diseases. According to the above criteria, clinical data of 73 patients of stage III( gastric cancer receiving neoadjuvant chemotherapy at Weifang People's Hospital from May 2015 to March 2017 were prospectively collected. The cohort study was adopted. After removing 3 patients who did not complete the chemotherapy, a total of 70 patients who completed the chemotherapy were included in the study. All the patients received SOX chemotherapy without nutritional support during chemotherapy. Changes of body composition and nutritional indicators were analyzed before and after chemotherapy, and according to the tumor regression after chemotherapy, patients were divided into response group (complete or sub-total tumor regression) and non-response group (tumor part, with or without a small amount of retreat) for stratified analysis. Of 70 gastric cancer patients, 40 were male and 30 were female with a age of (53.8±6.4) (28 to 64) years. There were 26 cases (37.1%) of stage III(a, 35 cases (50.0%) of stage III(b and 9 cases (12.9%) of stage III(c. There were 41 cases in response group and 29 cases in non-response group. Three patients (4.3%) were complete remission (CR) and 38 patients (54.3%) were partial remission (PR) in response group, while 23 cases (32.9%) were stable disease (SD) and 6 cases (8.6%) were progressive disease (PD). After neoadjuvant chemotherapy, the extracellular fluid of the whole patients increased from (13.3±1.7) L to (13.5±1.6) L (t=-2.044, P=0.045); the intracellular fluid decreased from (21.4±2.5) L to (21.1±2.4) L (t=2.369, P=0.021); the lymphocyte count decreased from (0.31±0.10)×10 9 /L to (0.29±0.10)×10 9 /L (t=1.706, P=0.009); the other indexes were not significantly different (all P>0.05). Stratified analysis showed that after neoadjuvant chemotherapy in response group, body mass increased from (60.1±8.8) kg to (61.0±8.3) kg (t=-2.773, P=0.008); body mass index increased from (21.9±2.4) kg/m 2 to (22.3±1.9) kg/m 2 (t=-3.479, P=0.001), while above two parameters did not differ significantly in non-response group. No significant differences in body mass, body mass index, skeletal muscle, inorganic salt, extracellular fluid, body fat, protein, upper arm circumference and intracellular fluid were found between two groups before and after neoadjuvant chemotherapy(all P>0.05). Except slight decrease in hemoglobin and lymphocyte, the other nutritional indicators were slightly elevated in response group, while the differences were not statistically significant(all P>0.05). All nutritional indicators in non-response group were slightly decreased without significant differences as well (all P>0.05). Neoadjuvant chemotherapy does not aggravate malnutrition in patients with locally advanced gastric cancer.